1
|
Periyasamy T, Asrafali SP, Lee J. Hydrogels for Translucent Wearable Electronics: Innovations in Materials, Integration, and Applications. Gels 2025; 11:372. [PMID: 40422391 DOI: 10.3390/gels11050372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2025] [Revised: 05/14/2025] [Accepted: 05/17/2025] [Indexed: 05/28/2025] Open
Abstract
Recent advancements in wearable electronics have significantly enhanced human-device interaction, enabling applications such as continuous health monitoring, advanced diagnostics, and augmented reality. While progress in material science has improved the flexibility, softness, and elasticity of these devices for better skin conformity, their optical properties, particularly transparency, remain relatively unexplored. Transparent wearable electronics offer distinct advantages: they allow for non-invasive health monitoring by enabling a clear view of biological systems and improve aesthetics by minimizing the visual presence of electronics on the skin, thereby increasing user acceptance. Hydrogels have emerged as a key material for transparent wearable electronics due to their high water content, excellent biocompatibility, and tunable mechanical and optical properties. Their inherent softness and stretchability allow intimate, stable contact with dynamic biological surfaces. Furthermore, their ability to support ion-based conductivity is advantageous for bioelectronic interfaces and physiological sensors. Current research is focused on advancing hydrogel design to improve transparency, mechanical resilience, conductivity, and adhesion. The core components of transparent wearable systems include physiological sensors, energy storage devices, actuators, and real-time displays. These must collectively balance efficiency, functionality, and long-term durability. Practical applications span continuous health tracking and medical imaging to next-generation interactive displays. Despite progress, challenges such as material durability, scalable manufacturing, and prolonged usability remain. Addressing these limitations will be crucial for the future development of transparent, functional, and user-friendly wearable electronics.
Collapse
Affiliation(s)
- Thirukumaran Periyasamy
- Department of Fiber System Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
| | | | - Jaewoong Lee
- Department of Fiber System Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
| |
Collapse
|
2
|
Ajeev A, Warfle T, Maslaczynska-Salome S, Alipoori S, Duprey C, Wujcik EK. From the synthesis of wearable polymer sensors to their potential for reuse and ultimate fate. Chem Sci 2025:d5sc01634g. [PMID: 40375863 PMCID: PMC12076081 DOI: 10.1039/d5sc01634g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2025] [Accepted: 04/28/2025] [Indexed: 05/18/2025] Open
Abstract
The objective of this perspective is to review the high-interest field of wearable polymer-based sensors-from synthesis to use and detection mechanisms-with a focus on their transient nature, potential for reuse, and ultimate fate. While many bulk polymers have long been mass-produced, the materials needed to create polymer-based sensors-often with unique properties (e.g., being electronically conductive)-are still highly active areas of research. Polymer-based materials and composites, when investigated as wearable sensors, have a wide range of applications with most falling under the umbrellas of biochemical and environmental sensing (i.e., chemical reactivity-based detection) or physical sensing (e.g., piezoresistive response). Since the long-term viability of these sensors is a function of not just their initial syntheses but also their ability to be durable, recyclable, or otherwise renewable, a discussion of both the technical and societal aspects of the reuse and ultimate fate of these materials will be covered. This discussion will focus on topics such as environmental impact, sterilization, and other methods for ensuring continued biocompatibility, as well as methods for the transformation, reclamation, or re-implementation of the sensor devices-a major issue the polymer community is facing.
Collapse
Affiliation(s)
- Arya Ajeev
- Materials Engineering And Nanosensor [MEAN] Laboratory, Department of Chemical and Biomedical Engineering, The University of Maine Orono Maine USA +1 207-581-2323 +1 207-581-2742
| | - Theodore Warfle
- Materials Engineering And Nanosensor [MEAN] Laboratory, Department of Chemical and Biomedical Engineering, The University of Maine Orono Maine USA +1 207-581-2323 +1 207-581-2742
- Advanced Structures and Composites Center [ASCC], The University of Maine Orono Maine USA +1 207-581-2323 +1 207-581-2742
| | - Sara Maslaczynska-Salome
- Materials Engineering And Nanosensor [MEAN] Laboratory, Department of Chemical and Biomedical Engineering, The University of Maine Orono Maine USA +1 207-581-2323 +1 207-581-2742
| | - Saeideh Alipoori
- Materials Engineering And Nanosensor [MEAN] Laboratory, Department of Chemical and Biomedical Engineering, The University of Maine Orono Maine USA +1 207-581-2323 +1 207-581-2742
- UNAM Institute of Materials Science and Nanotechnology, Bilkent University Ankara 06800 Turkey
| | - Colton Duprey
- Materials Engineering And Nanosensor [MEAN] Laboratory, Department of Chemical and Biomedical Engineering, The University of Maine Orono Maine USA +1 207-581-2323 +1 207-581-2742
- Advanced Structures and Composites Center [ASCC], The University of Maine Orono Maine USA +1 207-581-2323 +1 207-581-2742
| | - Evan K Wujcik
- Materials Engineering And Nanosensor [MEAN] Laboratory, Department of Chemical and Biomedical Engineering, The University of Maine Orono Maine USA +1 207-581-2323 +1 207-581-2742
- Advanced Structures and Composites Center [ASCC], The University of Maine Orono Maine USA +1 207-581-2323 +1 207-581-2742
| |
Collapse
|
3
|
Roy A, Afshari R, Jain S, Zheng Y, Lin MH, Zenkar S, Yin J, Chen J, Peppas NA, Annabi N. Advances in conducting nanocomposite hydrogels for wearable biomonitoring. Chem Soc Rev 2025; 54:2595-2652. [PMID: 39927792 DOI: 10.1039/d4cs00220b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2025]
Abstract
Recent advancements in wearable biosensors and bioelectronics have led to innovative designs for personalized health management devices, with biocompatible conducting nanocomposite hydrogels emerging as a promising building block for soft electronics engineering. In this review, we provide a comprehensive framework for advancing biosensors using these engineered nanocomposite hydrogels, highlighting their unique properties such as high electrical conductivity, flexibility, self-healing, biocompatibility, biodegradability, and tunable architecture, broadening their biomedical applications. We summarize key properties of nanocomposite hydrogels for thermal, biomechanical, electrophysiological, and biochemical sensing applications on the human body, recent progress in nanocomposite hydrogel design and synthesis, and the latest technologies in developing flexible and wearable devices. This review covers various sensor types, including strain, physiological, and electrochemical sensors, and explores their potential applications in personalized healthcare, from daily activity monitoring to versatile electronic skin applications. Furthermore, we highlight the blueprints of design, working procedures, performance, detection limits, and sensitivity of these soft devices. Finally, we address challenges, prospects, and future outlook for advanced nanocomposite hydrogels in wearable sensors, aiming to provide a comprehensive overview of their current state and future potential in healthcare applications.
Collapse
Affiliation(s)
- Arpita Roy
- Department of Chemical and Biomolecular Engineering, University of California Los Angeles, Los Angeles, California, 90095, USA.
| | - Ronak Afshari
- Department of Chemical and Biomolecular Engineering, University of California Los Angeles, Los Angeles, California, 90095, USA.
| | - Saumya Jain
- Department of Chemical and Biomolecular Engineering, University of California Los Angeles, Los Angeles, California, 90095, USA.
| | - Yuting Zheng
- Department of Chemical and Biomolecular Engineering, University of California Los Angeles, Los Angeles, California, 90095, USA.
| | - Min-Hsuan Lin
- Department of Chemical and Biomolecular Engineering, University of California Los Angeles, Los Angeles, California, 90095, USA.
| | - Shea Zenkar
- Department of Chemical and Biomolecular Engineering, University of California Los Angeles, Los Angeles, California, 90095, USA.
| | - Junyi Yin
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California, 90095, USA
| | - Jun Chen
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California, 90095, USA
| | - Nicholas A Peppas
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
- Institute for Biomaterials, Drug Delivery, and Regenerative Medicine, The University of Texas at Austin, Austin, TX 78712, USA
- Department of Pediatrics, Surgery and Perioperative Care, Dell Medical School, The University of Texas at Austin, Austin, TX, 78712, USA
- Division of Molecular Pharmaceutics and Drug Delivery, College of Pharmacy, The University of Texas at Austin, Austin, TX, 78712, USA
| | - Nasim Annabi
- Department of Chemical and Biomolecular Engineering, University of California Los Angeles, Los Angeles, California, 90095, USA.
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California, 90095, USA
| |
Collapse
|
4
|
Wei Z, Li Y, Guo S, Han R, Luo X. A wearable electrochemical sensor utilizing multifunctional hydrogel for antifouling ascorbic acid quantification in sweat. Anal Chim Acta 2025; 1337:343548. [PMID: 39800507 DOI: 10.1016/j.aca.2024.343548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2024] [Revised: 10/26/2024] [Accepted: 12/11/2024] [Indexed: 05/02/2025]
Abstract
The accurate and reliable quantification of the levels of disease markers in human sweat is of significance for health monitoring through wearable sensing technology, but the sensors performed in real sweat always suffer from biofouling that cause performance degradation or even malfunction. We herein developed a wearable antifouling electrochemical sensor based on a novel multifunctional hydrogel for the detection of targets in sweat. The integration of polyethylene glycol (PEG) into the sulfobetaine methacrylate (SBMA) hydrogel results in a robust network structure characterized by abundant hydrophilic groups on its surface, significantly enhancing the PEG-SBMA hydrogel's antifouling and mechanical properties. The wearable sweat sensor is specifically designed for ascorbic acid (AA) detection. The incorporation of a silver nanoparticles-molybdenum disulfide (AgNPs-MoS2) composite material into the hydrogel significantly enhances its catalytic properties towards AA. Electrochemical analysis confirms that the sensor reliably detects AA in real sweat with minimal interference from other components and bacteria, demonstrating its practical application potential. Furthermore, this multifunctional hydrogel's mechanical robustness and strong adhesion to various substrates ensure its practical applicability in wearable devices. This technology provides a foundation for accurate health monitoring in wearable sensors, enabling advanced, non-invasive diagnostic tools for personalized healthcare.
Collapse
Affiliation(s)
- Zhen Wei
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Yanxin Li
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Shuyue Guo
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Rui Han
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China.
| | - Xiliang Luo
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China.
| |
Collapse
|
5
|
Fu Q, Tang J, Wang W, Wang R. Biocomposite Polyvinyl Alcohol/Ferritin Hydrogels with Enhanced Stretchability and Conductivity for Flexible Strain Sensors. Gels 2025; 11:59. [PMID: 39852030 PMCID: PMC11764909 DOI: 10.3390/gels11010059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2024] [Revised: 12/31/2024] [Accepted: 01/08/2025] [Indexed: 01/26/2025] Open
Abstract
Protein-based hydrogels with stretchability and conductivity have potential applications in wearable electronic devices. However, the development of protein-based biocomposite hydrogels is still limited. In this work, we used natural ferritin to develop a PVA/ferritin biocomposite hydrogel by a repetitive freeze-thaw method. In this biocomposite hydrogel, ferritin, as a nano spring, forms a hydrogen bond with the PVA networks, which reduces the crystallinity of PVA and significantly improves the stretchability of the hydrogel. The fracture strain of the PVA/ferritin hydrogel is 203%, and the fracture stress is 112.2 kPa. The fracture toughness of the PVA/ferritin hydrogel is significantly enhanced to 147.03 kJ/m3, more than 3 times that of the PVA hydrogel (39.17 kJ/m3). In addition, the free residues and iron ions of ferritin endow the biocomposite hydrogel with enhanced ionic conductivity (0.15 S/m). The strain sensor constructed from this hydrogel shows good sensitivity (gauge factor = 1.7 at 150% strain), accurate real-time resistance response, and good long cyclic working stability when used for joint motion monitoring. The results indicate that a PVA/ferritin biocomposite hydrogel prepared by a facile method has enhanced stretchability and conductivity for flexible strain sensors. This work develops a new method for the preparation of protein-based hydrogels for wearable electronic devices.
Collapse
Affiliation(s)
- Qiang Fu
- China Shipbuilding Industry Corporation, Research Institute 712, Wuhan 430064, China;
| | - Junxiao Tang
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, China; (J.T.); (W.W.)
- Hubei Longzhong Laboratory, Xiangyang 441022, China
| | - Weimin Wang
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, China; (J.T.); (W.W.)
- Hubei Longzhong Laboratory, Xiangyang 441022, China
| | - Rongjie Wang
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, China; (J.T.); (W.W.)
- Hubei Longzhong Laboratory, Xiangyang 441022, China
| |
Collapse
|
6
|
Meng Q, Chi T, Guo S, Razbin M, Wu S, He S, Han S, Peng S. Highly sensitive strain sensors with ultra-low detection limit based on pre-defined serpentine cracks. MATERIALS HORIZONS 2025; 12:178-189. [PMID: 39466650 DOI: 10.1039/d4mh01136h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/30/2024]
Abstract
Flexible and stretchable strain sensors have garnered significant interest due to their potential applications in various fields including human health monitoring and human-machine interfaces. Previous studies have shown that strain sensors based on microcracks can exhibit both high sensitivity and a wide sensing range by manipulating the opening and closing of randomly generated cracks within conductive thin films. However, the uncontrolled nature of microcrack formation can cause a drift in the sensor's performance over time, affecting its accuracy and reliability. In this study, by pre-defining the cracks, we introduce a novel resistive strain sensor with high sensitivity, excellent linearity, an ultra-low detection limit, and robustness against off-axis deformation. The sensor operates on a simple mechanism involving the modulation of ohmic contact within intricately designed conductive serpentine curves, which are encapsulated by pre-stretched thin films. This design facilitates a high gauge factor of 495, exceptional linearity (R2 > 0.98), and an ultra-low detection threshold of 0.01% strain. Moreover, it maintains performance integrity during off-axis deformations such as bending and twisting, features that are indispensable for accurately monitoring human motion. To explore practical applications, a driving scenario was simulated where a sensor array was positioned on the driver's neck. The sensor output was analyzed using machine learning algorithms to successfully determine the presence of driver fatigue. This demonstration underlines the potential of our sensor technology in applications ranging from healthcare monitoring to wearable biomechanical systems and human-machine interfaces.
Collapse
Affiliation(s)
- Qingshi Meng
- College of Aerospace Engineering, Shenyang Aerospace University, Shenyang 110136, China.
| | - Tengfei Chi
- College of Aerospace Engineering, Shenyang Aerospace University, Shenyang 110136, China.
| | - Shuang Guo
- Health Service Department, Northern Theatre General Hospital, Shenyang, 110016, China
| | - Milad Razbin
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Shuying Wu
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Shuai He
- School of Mechanical and Manufacturing Engineering, The University of New South Wales, Sydney, NSW 2052, Australia.
| | - Sensen Han
- College of Aerospace Engineering, Shenyang Aerospace University, Shenyang 110136, China.
| | - Shuhua Peng
- School of Mechanical and Manufacturing Engineering, The University of New South Wales, Sydney, NSW 2052, Australia.
| |
Collapse
|
7
|
Li J, Wei H, Cui S, Hou H, Zhang Y, Zhang Y, Xu BB, Chu L, El-Bahy ZM, Melhi S, Sellami R, Guo Z. Polyvinyl alcohol/sodium alginate-based conductive hydrogels with in situ formed bimetallic zeolitic imidazolate frameworks towards soft electronics. Carbohydr Polym 2024; 346:122633. [PMID: 39245501 DOI: 10.1016/j.carbpol.2024.122633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2024] [Revised: 08/16/2024] [Accepted: 08/16/2024] [Indexed: 09/10/2024]
Abstract
Bimetallic zeolitic imidazolate frameworks (BZIFs) have received enormous attention due to their unique physi-chemical properties, but are rarely reported for electrically conductive hydrogel (ECH) applications arising from low intrinsic conductivity and poor dispersion. Herein, we propose an innovative strategy to prepare highly conductive and mechanically robust ECHs by in situ growing Ni/Co-BZIFs within the polyvinyl alcohol/sodium alginate dual network (PZPS). 2-methylimidazole (MeIM) ligands copolymerize with pyrrole monomers, enhancing the electrical conductivity; meanwhile, MeIM ligands act as anchor points for in-situ formation of BZIFs, effectively avoiding phase-to-phase interfacial resistance and ensuring a uniform distribution in the hydrogel network. Due to the synergism of Ni/Co-BZIFs, the PZPS hydrogel exhibits a high areal capacitance of 630.3 mF·cm-2 at a current density of 0.5 mA·cm-2, promising for flexible energy storage devices. In addition, PZPS shows excellent mechanical strength and toughness (with an ultimate tensile strength of 405.0 kPa and a toughness of 784.2 kJ·m-3 at an elongation at break of 474.0 %), a high gauge factor of up to 4.18 over an extremely wide stress range of 0-42 kPa when used as flexible wearable strain/pressure sensors. This study provides new insights to incorporating highly conductive and uniformly dispersed ZIFs into hydrogels for flexible wearable electronics.
Collapse
Affiliation(s)
- Jiongru Li
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, Tianjin Key Laboratory of Multivariate Identification for Port Hazardous Chemical Substances, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Huige Wei
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, Tianjin Key Laboratory of Multivariate Identification for Port Hazardous Chemical Substances, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China.
| | - Shuaichuan Cui
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China
| | - Hua Hou
- College of Materials Science and Engineering, Taiyuan University of Science and Technology, Taiyuan 030024, China
| | - Yifan Zhang
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China
| | | | - Ben Bin Xu
- Department of Mechanical and Construction Engineering, Northumbria University, Newcastle Upon Tyne NE1 8ST, UK
| | - Liqiang Chu
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, Tianjin Key Laboratory of Multivariate Identification for Port Hazardous Chemical Substances, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Zeinhom M El-Bahy
- Department of Chemistry, Faculty of Science, Al-Azhar University, Nasr City 11884, Cairo, Egypt
| | - Saad Melhi
- Department of Chemistry, College of Science, University of Bisha, Bisha, 61922, Saudi Arabia
| | - Rahma Sellami
- Department of Computer Science, Applied College, Northern Border University, Rafha 91911, Saudi Arabia
| | - Zhanhu Guo
- Department of Mechanical and Construction Engineering, Northumbria University, Newcastle Upon Tyne NE1 8ST, UK.
| |
Collapse
|
8
|
Ji Y, Li T, Abo-Dief HM, Abualnaja KM, Wei M, Zhang J, Wang X, Zhang J, Guo Z, El-Bahy ZM, Wei H. Polyacrylamide/starch hydrogels doped with layered double hydroxides towards strain sensing applications. Int J Biol Macromol 2024; 280:136333. [PMID: 39482133 DOI: 10.1016/j.ijbiomac.2024.136333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2024] [Revised: 09/21/2024] [Accepted: 10/03/2024] [Indexed: 11/03/2024]
Abstract
Electrically conductive hydrogels have attracted enormous attention due to the rapid development of flexible electronics. In this paper, the application of layered double hydroxides (LDHs) in the field of conductive hydrogel for strain sensing is firstly explored. LDHs are introduced to the polyacrylamide (PAM)/starch (St) semi-interpenetrating network (SIPN) to fabricate conductive PAM/St/LDHs (PSL) hydrogels for strain sensing applications. The results show that LDHs incorporated into PAM/St SIPN as inorganic nano fillers not only improve the mechanical strength, but also innovatively endow the hydrogel with electrical conductivity properties. The PSL hydrogels exhibit excellent mechanical properties (with an elongation strain of 1750 % and a fracture strength of 0.22 MPa) and decent sensing properties (with a gauge factor of 2.73). As a proof of concept, an 8*8 sensing array based on PSL hydrogels is designed to realize the visualization of pressure sensing, demonstrating the broad prospect of PSL hydrogels in applications of human-computer interaction, flexible wearable and soft robotics.
Collapse
Affiliation(s)
- Yanxiu Ji
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, Tianjin Key Laboratory of Multivariate Identification for Port Hazardous Chemical Substances, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China; State Key Laboratory of Biobased Fiber Manufacturing Technology, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Tuo Li
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, Tianjin Key Laboratory of Multivariate Identification for Port Hazardous Chemical Substances, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Hala M Abo-Dief
- Department of Science and Technology, University College-Ranyah, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
| | - Khamael M Abualnaja
- Department of Chemistry, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
| | - Mojieming Wei
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, Tianjin Key Laboratory of Multivariate Identification for Port Hazardous Chemical Substances, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Jing Zhang
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, Tianjin Key Laboratory of Multivariate Identification for Port Hazardous Chemical Substances, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Xuanye Wang
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, Tianjin Key Laboratory of Multivariate Identification for Port Hazardous Chemical Substances, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Jing Zhang
- School of Chemical and Biological Engineering, Taiyuan University of Science and Technology, Taiyuan, Shanxi 030021, China
| | - Zhanhu Guo
- Department of Mechanical and Construction Engineering, Faculty of Engineering and Environment, Northumbria University, Newcastle Upon Tyne NE1 8ST, UK
| | - Zeinhom M El-Bahy
- Department of Chemistry, Faculty of Science, Al-Azhar University, Nasr City, 11884, Cairo, Egypt
| | - Huige Wei
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, Tianjin Key Laboratory of Multivariate Identification for Port Hazardous Chemical Substances, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China; State Key Laboratory of Biobased Fiber Manufacturing Technology, Tianjin University of Science and Technology, Tianjin 300457, China.
| |
Collapse
|
9
|
Sun Z, Ou Q, Dong C, Zhou J, Hu H, Li C, Huang Z. Conducting polymer hydrogels based on supramolecular strategies for wearable sensors. EXPLORATION (BEIJING, CHINA) 2024; 4:20220167. [PMID: 39439497 PMCID: PMC11491309 DOI: 10.1002/exp.20220167] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 02/02/2024] [Indexed: 10/25/2024]
Abstract
Conductive polymer hydrogels (CPHs) are gaining considerable attention in developing wearable electronics due to their unique combination of high conductivity and softness. However, in the absence of interactions, the incompatibility between hydrophobic conductive polymers (CPs) and hydrophilic polymer networks gives rise to inadequate bonding between CPs and hydrogel matrices, thereby significantly impairing the mechanical and electrical properties of CPHs and constraining their utility in wearable electronic sensors. Therefore, to endow CPHs with good performance, it is necessary to ensure a stable and robust combination between the hydrogel network and CPs. Encouragingly, recent research has demonstrated that incorporating supramolecular interactions into CPHs enhances the polymer network interaction, improving overall CPH performance. However, a comprehensive review focusing on supramolecular CPH (SCPH) for wearable sensing applications is currently lacking. This review provides a summary of the typical supramolecular strategies employed in the development of high-performance CPHs and elucidates the properties of SCPHs that are closely associated with wearable sensors. Moreover, the review discusses the fabrication methods and classification of SCPH sensors, while also exploring the latest application scenarios for SCPH wearable sensors. Finally, it discusses the challenges of SCPH sensors and offers suggestions for future advancements.
Collapse
Affiliation(s)
- Zhiyuan Sun
- School of Chemical Engineering and TechnologyXi'an Jiaotong UniversityXi'anPeople's Republic of China
| | - Qingdong Ou
- Macao Institute of Materials Science and Engineering (MIMSE)Faculty of Innovation EngineeringMacau University of Science and TechnologyMacao TaipaPeople's Republic of China
| | - Chao Dong
- Chemistry and Physics DepartmentCollege of Art and ScienceThe University of Texas of Permian BasinOdessaTexasUSA
| | - Jinsheng Zhou
- College of Chemistry and Environmental EngineeringShenzhen UniversityShenzhenPeople's Republic of China
| | - Huiyuan Hu
- College of Chemistry and Environmental EngineeringShenzhen UniversityShenzhenPeople's Republic of China
| | - Chong Li
- Guangdong Polytechnic of Science and TechnologyZhuhaiPeople's Republic of China
| | - Zhandong Huang
- School of Chemical Engineering and TechnologyXi'an Jiaotong UniversityXi'anPeople's Republic of China
| |
Collapse
|
10
|
Liu Q, Yu Z, Fan K, Huang H, Zhang B. Asymmetric Hydrogel Electrolyte Featuring a Customized Anode and Cathode Interfacial Chemistry for Advanced Zn-I 2 Batteries. ACS NANO 2024; 18:22484-22494. [PMID: 39103244 DOI: 10.1021/acsnano.4c07880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/07/2024]
Abstract
An integrated asymmetric hydrogel electrolyte with a tailored composition and chemical structure on the cathode/anode-electrolyte interface is designed to boost the cost-effective, high-energy Zn-I2 battery. Such a configuration concurrently addresses the parasitic reactions on the Zn anode side and the polyiodide shuttle issue afflicting the cathode. Specifically, the Zn2+-cross-linked sodium alginate and carrageenan dual network (Carra-Zn-Alg) is adopted to guide the Zn2+ transport, achieving a dendrite-free morphology on the Zn surface and ensuring long-term stability. For the cathode side, the poly(vinyl alcohol)-strengthened poly(3,4-ethylenedioxythiophene)polystyrenesulfonate hydrogel (PVA-PEDOT) with high conductivity is employed to trap polyiodide and accelerate electron transfer for mitigating the shuttle effect and facilitating I2/I- redox kinetics. Attributing to the asymmetrical architecture with a customized interfacial chemistry, the optimized Zn-I2 cell exhibits a superior Coulombic efficiency of 99.84% with a negligible capacity degradation at 0.1 A g-1 and an enhanced stability of 10 000 cycles at 5 A g-1. The proposed asymmetric hydrogel provides a promising route to simultaneously resolve the distinct challenges encountered by the cathode and anode interfaces in rechargeable batteries.
Collapse
Affiliation(s)
- Qun Liu
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Hong Kong 999077, China
| | - Zhenlu Yu
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Hong Kong 999077, China
| | - Ke Fan
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Hong Kong 999077, China
| | - Haitao Huang
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Hong Kong 999077, China
| | - Biao Zhang
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Hong Kong 999077, China
| |
Collapse
|
11
|
Sang C, Wang S, Jin X, Cheng X, Xiao H, Yue Y, Han J. Nanocellulose-mediated conductive hydrogels with NIR photoresponse and fatigue resistance for multifunctional wearable sensors. Carbohydr Polym 2024; 333:121947. [PMID: 38494214 DOI: 10.1016/j.carbpol.2024.121947] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 01/25/2024] [Accepted: 02/12/2024] [Indexed: 03/19/2024]
Abstract
The rapid development of hydrogels has garnered significant attention in health monitoring and human motion sensing. However, the synthesis of multifunctional conductive hydrogels with excellent strain/pressure sensing and photoresponsiveness remains a challenge. Herein, the conductive hydrogels (BPTP) with excellent mechanical properties, fatigue resistance and photoresponsive behavior composed of polyacrylamide (PAM) matrix, 2,2,6,6-tetramethylpiperidin-1-yloxy-oxidized cellulose nanofibers (TOCNs) reinforcement and polydopamine-modified black phosphorus (BP@PDA) photosensitizer are prepared through a facile free-radical polymerization approach. The PDA adhered to the BP surface by π-π stacking promotes the optical properties of BP while also preventing BP oxidation from water. Through hydrogen bonding interactions, TOCNs improve the homogeneous dispersion of BP@PDA nanosheets and the mechanical toughness of BPTP. Benefiting from the synergistic effect of PDA and TOCNs, the conductive BPTP integrates superior mechanical performances, excellent photoelectric response and photothermal conversion capability. The BPTP-based sensor with high cycling stability demonstrates superior strain sensitivity (GF = 6.0) and pressure sensing capability (S = 0.13 kPa-1) to monitor various human activities. Therefore, this work delivers an alternative construction strategy for generating high-performance conductive hydrogels as multifunctional wearable sensors.
Collapse
Affiliation(s)
- Chenyu Sang
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, Joint International Research Lab of Lignocellulosic Functional Materials, College of Materials Science and Engineering, Nanjing Forestry University, Nanjing 210037, China
| | - Shaowei Wang
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, Joint International Research Lab of Lignocellulosic Functional Materials, College of Materials Science and Engineering, Nanjing Forestry University, Nanjing 210037, China
| | - Xiaoyue Jin
- Nanjing Institute of Product Quality Inspection, Nanjing Institute of Quality Development and Advanced Technology Application, Nanjing 210019, China
| | - Xiaoyu Cheng
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, Joint International Research Lab of Lignocellulosic Functional Materials, College of Materials Science and Engineering, Nanjing Forestry University, Nanjing 210037, China
| | - Huining Xiao
- Department of Chemical Engineering, University of New Brunswick, 15 Dineen Drive, Fredericton, NB E3B 5A3, Canada
| | - Yiying Yue
- College of Biology and Environment, Nanjing Forestry University, Nanjing 210037, China.
| | - Jingquan Han
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, Joint International Research Lab of Lignocellulosic Functional Materials, College of Materials Science and Engineering, Nanjing Forestry University, Nanjing 210037, China.
| |
Collapse
|
12
|
Zhang X, Zhang S, Chen X, Ye Z, Liu W, Liu X, Wang X. Theranostic antibacterial hydrogel based on biopolymers cross-linked and doped with phytic acid from rice bran for wound healing. Int J Biol Macromol 2024; 269:132080. [PMID: 38705314 DOI: 10.1016/j.ijbiomac.2024.132080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 04/17/2024] [Accepted: 05/02/2024] [Indexed: 05/07/2024]
Abstract
Theranostic antibacterial wound dressing is highly recommended in practical applications. The conventional methods of integrating diagnostic and therapeutic functions have the disadvantages of complicated preparation, mutual interference, inability to effectively broad spectrum antibacterial property, and easy to induce drug-resistant bacteria. Herein, a pH and light-responsive theranostic antibacterial hydrogel is developed by biopolymers polyvinyl alcohol (PVA) and polyaniline (PANI), and cross-linking with phytic acid (PA), which is widely present in rice bran. The biological polymer-based conductive hydrogel enables timely diagnosis and photothermal sterilization in-situ for wound healing. Because PANI is highly sensitive to pH changes in the bacterial microenvironment, the hydrogel can detect bacterial infections at concentrations as low as 103 CFU/mL. Subsequently, PANI absorbs near-infrared light to achieve on-demand exothermic sterilization (under 808 nm irradiation for 20 min, the killing ratios for Staphylococcus aureus and Escherichia coli reached almost 100 %). In addition, the hydrogel can monitor the intensity of joint movement to avoid wound re-tearing sensitively. In vitro cytotoxicity and hemocompatibility experiments and in vivo full-thickness infected wound model indicate that the hydrogel has good biocompatibility, antibacterial ability, and can accelerate the wound healing effectively. This work will promote the development of wearable electronic devices and precision medicine.
Collapse
Affiliation(s)
- Xiaoyang Zhang
- School of Materials Science and Engineering, Zhengzhou Key Laboratory of Flexible Electronic Materials and Thin-Film Technologies, Henan Innovation Center for Functional Polymer Membrane Materials, Zhengzhou University, Zhengzhou 450001, PR China
| | - Shike Zhang
- School of Materials Science and Engineering, Zhengzhou Key Laboratory of Flexible Electronic Materials and Thin-Film Technologies, Henan Innovation Center for Functional Polymer Membrane Materials, Zhengzhou University, Zhengzhou 450001, PR China; Liming Research & Design Institute of Chemical Industry Co., Ltd, Luoyang 471001, PR China
| | - Xin Chen
- College of Food Science and Engineering, National Engineering Research Center of Wheat and Corn Further Processing, Henan University of Technology, Zhengzhou 450001, PR China.
| | - Zonghui Ye
- School of Materials Science and Engineering, Zhengzhou Key Laboratory of Flexible Electronic Materials and Thin-Film Technologies, Henan Innovation Center for Functional Polymer Membrane Materials, Zhengzhou University, Zhengzhou 450001, PR China
| | - Wentao Liu
- School of Materials Science and Engineering, Zhengzhou Key Laboratory of Flexible Electronic Materials and Thin-Film Technologies, Henan Innovation Center for Functional Polymer Membrane Materials, Zhengzhou University, Zhengzhou 450001, PR China
| | - Xuying Liu
- School of Materials Science and Engineering, Zhengzhou Key Laboratory of Flexible Electronic Materials and Thin-Film Technologies, Henan Innovation Center for Functional Polymer Membrane Materials, Zhengzhou University, Zhengzhou 450001, PR China
| | - Xianghong Wang
- School of Materials Science and Engineering, Zhengzhou Key Laboratory of Flexible Electronic Materials and Thin-Film Technologies, Henan Innovation Center for Functional Polymer Membrane Materials, Zhengzhou University, Zhengzhou 450001, PR China.
| |
Collapse
|
13
|
Lei T, Pan J, Wang N, Xia Z, Zhang Q, Fan J, Tao L, Shou W, Gao Y. Cold-resistant, highly stretchable ionic conductive hydrogels for intelligent motion recognition in winter sports. MATERIALS HORIZONS 2024; 11:1234-1250. [PMID: 38131412 DOI: 10.1039/d3mh02013d] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
Conductive hydrogels have attracted much attention for their wide application in the field of flexible wearable sensors due to their outstanding flexibility, conductivity and sensing properties. However, the weak mechanical properties, lack of frost resistance and susceptibility to microbial contamination of traditional conductive hydrogels greatly limit their practical application. In this work, multifunctional polyvinyl alcohol (PVA)/carboxymethyl cellulose (CMC)/poly(acrylamide-co-1-vinyl-3-butylimidazolium bromide) (P(AAm-co-VBIMBr)) (PCPAV) ionic conductive hydrogels with high strength and good conductive, transparent, anti-freezing and antibacterial properties were constructed by introducing a network of chemically crosslinked AAm and VBIMBr copolymers into the base material of PVA and CMC by in situ free radical polymerization. Owing to the multiple interactions between the polymers, including covalent crosslinking, multiple hydrogen bonding interactions, and electrostatic interactions, the obtained ionic conductive hydrogels exhibit a high tensile strength (360.6 kPa), a large elongation at break (810.6%), good toughness, and fatigue resistance properties. The introduction of VBIMBr endows the PCPAV hydrogels with excellent transparency (∼92%), a high ionic conductivity (15.2 mS cm-1), antimicrobial activity and good flexibility and conductivity at sub-zero temperatures. Notably, the PCPAV hydrogels exhibit a wide strain range (0-800%), high strain sensitivity (GF = 3.75), fast response, long-term stability, and fantastic durability, which enable them to detect both large joint movements and minute muscle movements. Based on these advantages, it is believed that the PCPAV-based hydrogel sensors would have potential applications in health monitoring, human motion detection, soft robotics, ionic skins, human-machine interfaces, and other flexible electronic devices.
Collapse
Affiliation(s)
- Tongda Lei
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China.
| | - Jiajun Pan
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China.
| | - Ning Wang
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China.
| | - Zhaopeng Xia
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China.
| | - Qingsong Zhang
- School of Material Science and Engineering, Tiangong University, Tianjin 300387, China.
| | - Jie Fan
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China.
| | - Lei Tao
- The Key Laboratory of Bioorganic Phosphorus Chemistry and Chemical Biology (Ministry of Education), Department of Chemistry, Tsinghua University, Beijing 100084, P. R. China
| | - Wan Shou
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR 72701, USA
| | - Yu Gao
- School of Material Science and Engineering, Tiangong University, Tianjin 300387, China.
| |
Collapse
|
14
|
Zhong Y, Lin Q, Yu H, Shao L, Cui X, Pang Q, Zhu Y, Hou R. Construction methods and biomedical applications of PVA-based hydrogels. Front Chem 2024; 12:1376799. [PMID: 38435666 PMCID: PMC10905748 DOI: 10.3389/fchem.2024.1376799] [Citation(s) in RCA: 43] [Impact Index Per Article: 43.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 02/05/2024] [Indexed: 03/05/2024] Open
Abstract
Polyvinyl alcohol (PVA) hydrogel is favored by researchers due to its good biocompatibility, high mechanical strength, low friction coefficient, and suitable water content. The widely distributed hydroxyl side chains on the PVA molecule allow the hydrogels to be branched with various functional groups. By improving the synthesis method and changing the hydrogel structure, PVA-based hydrogels can obtain excellent cytocompatibility, flexibility, electrical conductivity, viscoelasticity, and antimicrobial properties, representing a good candidate for articular cartilage restoration, electronic skin, wound dressing, and other fields. This review introduces various preparation methods of PVA-based hydrogels and their wide applications in the biomedical field.
Collapse
Affiliation(s)
- Yi Zhong
- Zhejiang Key Laboratory of Pathophysiology, Department of Cell Biology and Regenerative Medicine, Health Science Center, Ningbo University, Ningbo, China
| | - Qi Lin
- Zhejiang Key Laboratory of Pathophysiology, Department of Cell Biology and Regenerative Medicine, Health Science Center, Ningbo University, Ningbo, China
| | - Han Yu
- Zhejiang Key Laboratory of Pathophysiology, Department of Cell Biology and Regenerative Medicine, Health Science Center, Ningbo University, Ningbo, China
| | - Lei Shao
- Research Institute for Medical and Biological Engineering, Ningbo University, Ningbo, China
| | - Xiang Cui
- Department of Otorhinolaryngology, Lihuili Hospital of Ningbo University, Ningbo, China
| | - Qian Pang
- Zhejiang Key Laboratory of Pathophysiology, Department of Cell Biology and Regenerative Medicine, Health Science Center, Ningbo University, Ningbo, China
| | - Yabin Zhu
- Zhejiang Key Laboratory of Pathophysiology, Department of Cell Biology and Regenerative Medicine, Health Science Center, Ningbo University, Ningbo, China
| | - Ruixia Hou
- Zhejiang Key Laboratory of Pathophysiology, Department of Cell Biology and Regenerative Medicine, Health Science Center, Ningbo University, Ningbo, China
| |
Collapse
|
15
|
Shi J, Wang S, Wang H, Gu J. Mechanically Tough and Highly Stretchable Hydrogels Based on Polyurethane for Sensitive Strain Sensor. Polymers (Basel) 2023; 15:3902. [PMID: 37835950 PMCID: PMC10575362 DOI: 10.3390/polym15193902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 09/21/2023] [Accepted: 09/25/2023] [Indexed: 10/15/2023] Open
Abstract
Hydrogels with flexible and stretchable properties are ideal for applications in wearable sensors. However, traditional hydrogel-based sensors suffer from high brittleness and low electrical sensitivity. In this case, to solve this dilemma, a macromolecular polyurethane crosslinking agent (PCA) was designed and prepared; after that, PCA and two-dimensional (2D) MXene nanosheets were both introduced into a covalently crosslinked network to enhance the comprehensive mechanical and electrochemical properties of the hydrogels. The macromolecular polyurethane crosslinking agent promotes high-tensile strength and highly stretchable capacity by suitable covalent crosslinking. The optimized hydrogel, which exhibited maximum tensile strength and maximum elongation at break, had results of 1.21 MPa and 644%, respectively. Two-dimensional MXene nanosheets provide hydrogel with high electrical conductivity and strain sensitivity, producing a wearable device for the continuous monitoring of human movements and facial microexpressions. This study demonstrated an efficient structure design strategy for building mechanically tough, highly stretchable, and sensitive dual-mode MXenes-based wearable sensors.
Collapse
Affiliation(s)
- Jianyang Shi
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu 610065, China; (J.S.); (H.W.)
- College of Biomass Science and Engineering, Sichuan University, Chengdu 610065, China;
| | - Shuang Wang
- College of Biomass Science and Engineering, Sichuan University, Chengdu 610065, China;
| | - Haibo Wang
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu 610065, China; (J.S.); (H.W.)
- College of Biomass Science and Engineering, Sichuan University, Chengdu 610065, China;
| | - Jun Gu
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu 610065, China; (J.S.); (H.W.)
- College of Biomass Science and Engineering, Sichuan University, Chengdu 610065, China;
| |
Collapse
|
16
|
Balakrishnan G, Song J, Khair AS, Bettinger CJ. Poisson-Nernst-Planck framework for modelling ionic strain and temperature sensors. J Mater Chem B 2023; 11:5544-5551. [PMID: 36810661 PMCID: PMC10293092 DOI: 10.1039/d2tb02819k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
Ionically conductive hydrogels are gaining traction as sensing and structural materials for use bioelectronic devices. Hydrogels that feature large mechanical compliances and tractable ionic conductivities are compelling materials that can sense physiological states and potentially modulate the stimulation of excitable tissue because of the congruence in electro-mechanical properties across the tissue-material interface. However, interfacing ionic hydrogels with conventional DC voltage-based circuits poses several technical challenges including electrode delamination, electrochemical reaction, and drifting contact impedance. Utilizing alternating voltages to probe ion-relaxation dynamics has been shown to be a viable alternative for strain and temperature sensing. In this work, we present a Poisson-Nernst-Planck theoretical framework to model ion transport under alternating fields within conductors subject to varying strains and temperatures. Using simulated impedance spectra, we develop key insights about the relationship between frequency of the applied voltage perturbation and sensitivity. Lastly, we perform preliminary experimental characterization to demonstrate the applicability of the proposed theory. We believe this work provides a useful perspective that is applicable to the design of a variety of ionic hydrogel-based sensors for biomedical and soft robotic applications.
Collapse
Affiliation(s)
- Gaurav Balakrishnan
- Materials Science and Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213, USA.
| | - Jiwoo Song
- Materials Science and Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213, USA.
| | - Aditya S Khair
- Chemical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213, USA
| | - Christopher J Bettinger
- Materials Science and Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213, USA.
- Biomedical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213, USA
| |
Collapse
|
17
|
Dai W, Wang J, Xiang K, Hu W, Sun J, Zhang H, Wang L. Highly Stretchable, Ultra-Sensitive, and Self-Healable Multifunctional Flexible Conductive Hydrogel Sensor for Motion Detection and Information Transmission. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 37302071 DOI: 10.1021/acsami.3c06222] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Self-healable flexible sensing materials are extensively investigated for their potential use in human motion detection, healthcare monitoring, and other fields. However, the existing self-healable flexible sensing materials have limited their application in real life due to the weak stability of the conductive network and the difficulty in balancing stretchability and self-healing performances. In this paper, a flexible sensor with skin-like properties was prepared by composing a polymer composite hydrogel with a multiple network structure consisting of polyaniline, polyvinyl alcohol, chitosan, and phytic acid. The composite hydrogel was tested and proved to own high mechanical properties (stretchability ≈ 565%, strength ≈ 1.4 MPa), good electrical conductivity (0.214 S cm-1), excellent self-healing properties (>99% healing efficiency in a 4 h healing period), and antibacterial properties. It had high sensitivity and a wide sensing range for strain and pressure, making it possible to manufacture multifunctional flexible sensors with comprehensive performance exceeding that of most flexible sensing materials. Notably, this polymer composite hydrogel can be manufactured in a large area and at a low cost, which is beneficial for its further application in many fields.
Collapse
Affiliation(s)
- Weisen Dai
- College of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Street, Shanghai 201620, China
| | - Jincheng Wang
- College of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Street, Shanghai 201620, China
| | - Kailing Xiang
- College of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Street, Shanghai 201620, China
| | - Wanying Hu
- College of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Street, Shanghai 201620, China
| | - Jibo Sun
- Wopu New Material Technology (Shanghai) Co., Ltd., Shanghai 201620, P. R. China
| | - Hua Zhang
- Qidong Xirui New Material Technology Co., Ltd., Jiangsu 226200, P. R. China
| | - Liming Wang
- Zhejiang Tianshu Seal Co., Ltd., Zhejiang 314105, P. R. China
| |
Collapse
|
18
|
Zhang Y, Jiang L, Zhang H, Li Q, Ma N, Zhang X, Ma L. High-Strength Double-Network Conductive Hydrogels Based on Polyvinyl Alcohol and Polymerizable Deep Eutectic Solvent. Molecules 2023; 28:4690. [PMID: 37375245 DOI: 10.3390/molecules28124690] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/03/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023] Open
Abstract
Conductive hydrogels feature the flexibility of soft materials plus conductive properties providing functionality for effectively sticking to the epidermis and detecting human activity signals. Their stable electrical conductivity also effectively avoids the problem of uneven distribution of solid conductive fillers inside traditional conductive hydrogels. However, the simultaneous integration of high mechanical strength, stretchability, and transparency through a simple and green fabrication method remains a great challenge. Herein, a polymerizable deep eutectic solvent (PDES) composed of choline chloride and acrylic acid was added to a biocompatible PVA matrix. The double-network hydrogels were then simply prepared by thermal polymerization and one freeze-thaw method. The introduction of the PDES significantly improved the tensile properties (1.1 MPa), ionic conductivity (2.1 S/m), and optical transparency (90%) of the PVA hydrogels. When the gel sensor was fixed to human skin, real-time monitoring of a variety of human activities could be implemented with accuracy and durability. Such a simple preparation method performed by combining a deep eutectic solvent with traditional hydrogels offers a new avenue to construct multifunctional conductive hydrogel sensors with excellent performance.
Collapse
Affiliation(s)
- Yihan Zhang
- Qingdao Innovation and Development Center, Harbin Engineering University, Qingdao 266400, China
- State Key Laboratory for Marine Corrosion and Protection, Luoyang Ship Material Research Institute (LSMRI), Qingdao 266237, China
| | - Lei Jiang
- Qingdao Innovation and Development Center, Harbin Engineering University, Qingdao 266400, China
| | - Haibing Zhang
- State Key Laboratory for Marine Corrosion and Protection, Luoyang Ship Material Research Institute (LSMRI), Qingdao 266237, China
| | - Qingyin Li
- State Key Laboratory for Marine Corrosion and Protection, Luoyang Ship Material Research Institute (LSMRI), Qingdao 266237, China
| | - Ning Ma
- Qingdao Innovation and Development Center, Harbin Engineering University, Qingdao 266400, China
| | - Xinyue Zhang
- Qingdao Innovation and Development Center, Harbin Engineering University, Qingdao 266400, China
| | - Li Ma
- State Key Laboratory for Marine Corrosion and Protection, Luoyang Ship Material Research Institute (LSMRI), Qingdao 266237, China
| |
Collapse
|
19
|
Li T, Wei H, Zhang Y, Wan T, Cui D, Zhao S, Zhang T, Ji Y, Algadi H, Guo Z, Chu L, Cheng B. Sodium alginate reinforced polyacrylamide/xanthan gum double network ionic hydrogels for stress sensing and self-powered wearable device applications. Carbohydr Polym 2023; 309:120678. [PMID: 36906361 DOI: 10.1016/j.carbpol.2023.120678] [Citation(s) in RCA: 47] [Impact Index Per Article: 23.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 01/20/2023] [Accepted: 02/04/2023] [Indexed: 02/11/2023]
Abstract
Strong and ductile sodium alginate (SA) reinforced polyacrylamide (PAM)/xanthan gum (XG) double network ionic hydrogels were constructed for stress sensing and self-powered wearable device applications. In the designed network of PXS-Mn+/LiCl (short for PAM/XG/SA-Mn+/LiCl, where Mn+ stands for Fe3+, Cu2+ or Zn2+), PAM acts as a flexible hydrophilic skeleton, and XG functions as a ductile second network. The macromolecule SA interacts with metal ion Mn+ to form a unique complex structure, significantly improving the mechanical strength of the hydrogel. The addition of inorganic salt LiCl endows the hydrogel with high electrical conductivity, and meanwhile reduces the freezing point and prevents water loss of the hydrogel. PXS-Mn+/LiCl exhibits excellent mechanical properties and ultra-high ductility (a fracture tensile strength up to 0.65 MPa and a fracture strain up to 1800%), and high stress-sensing performance (a high GF up to 4.56 and pressure sensitivity of 0.122). Moreover, a self-powered device with a dual-power-supply mode, i.e., PXS-Mn+/LiCl-based primary battery and TENG, and a capacitor as the energy storage component was constructed, which shows promising prospects for self-powered wearable electronics.
Collapse
Affiliation(s)
- Tuo Li
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Huige Wei
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China; State Key Laboratory of Biobased Fiber Manufacturing Technology, Tianjin University of Science and Technology, Tianjin 300457, China.
| | | | - Tong Wan
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Dapeng Cui
- College of Light Industry Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Shixiang Zhao
- College of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin 300222, China
| | - Teng Zhang
- College of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin 300222, China
| | - Yanxiu Ji
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Hassan Algadi
- Department of Electrical Engineering, Faculty of Engineering, Najran University, Najran 11001, Saudi Arabia; College of Materials Science and Engineering, Taiyuan University of Science and Technology, Taiyuan, 030024, China
| | - Zhanhu Guo
- Mechanical and Construction Engineering, Faculty of Engineering and Environment, Northumbria University, Newcastle Upon Tyne NE1 8ST, UK
| | - Liqiang Chu
- Tianjin Key Laboratory of Brine Chemical Engineering and Resource Eco-utilization, College of Chemical Engineering and Materials Science, Tianjin University of Science and Technology, Tianjin 300457, China.
| | - Bowen Cheng
- State Key Laboratory of Biobased Fiber Manufacturing Technology, Tianjin University of Science and Technology, Tianjin 300457, China; College of Light Industry Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China.
| |
Collapse
|
20
|
Controlled 5‐FU Release from P(NIPAM‐co‐VIm)‐g‐PEG Dual Responsive Hydrogels. ChemistrySelect 2023. [DOI: 10.1002/slct.202203522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2023]
|
21
|
Surface Characterization and Electrical Properties of Low Energy Irradiated PANI/PbS Polymeric Nanocomposite Materials. INORGANICS 2023. [DOI: 10.3390/inorganics11020074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
In this work, nanocomposite samples of polyaniline (PANI) and lead sulfide nanoparticles (PbSNPs) were prepared, utilizing the solution preparation method, for implantation in energy storage elements. The PANI/PbS films were irradiated by different fluences of oxygen beam: 5 × 1016, 10 × 1016, and 15 × 1016 ions.cm−2. The composite was investigated by XRD, SEM, DSC, and FTIR. After ion irradiation, the Tg and Tm values decreased by 4.8 °C and 10.1 °C, respectively. The conductivities, electrical impedances, and electrical moduli of untreated and irradiated samples were examined in frequencies ranging from 102 Hz to 5 MHz. Moreover, the ion beam caused a modification in the dielectric characteristics of PANI/PbS. The dielectric constant ε′ was improved from 31 to 611, and the electrical conductivity increased from 1.45 × 10−3 S/cm to 25.9 × 10−3 S/cm by enhancing the fluence to 15 × 1016 ions.cm−2. Additionally, the potential energy barrier, Wm, decreased from 0.43 eV to 0.23 eV. The induced changes in the dielectric properties and structural characteristics of the PANI/PbS samples were determined. These modifications provide an opportunity to use irradiated PANI/PbS samples for several applications, including microelectronics, batteries, and storage of electrical energy.
Collapse
|
22
|
Song B, Fan X, Gu H. Chestnut-Tannin-Crosslinked, Antibacterial, Antifreezing, Conductive Organohydrogel as a Strain Sensor for Motion Monitoring, Flexible Keyboards, and Velocity Monitoring. ACS APPLIED MATERIALS & INTERFACES 2023; 15:2147-2162. [PMID: 36562537 DOI: 10.1021/acsami.2c18441] [Citation(s) in RCA: 35] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Flexible sensing devices (FSDs) fabricated using conductive hydrogels have attracted researchers' extensive enthusiasm in recent years due to their versatility. Considering the complexity of their application environments, the integration of various functional characteristics (e.g., excellent mechanical, antibacterial, and antifreezing properties) is an important guarantee for FSDs to stably perform their applications in different environments. Herein, we developed a multifunctional conductive polyvinyl alcohol (PVA) organohydrogel PVA-CT-Ag-Al-Gly (PCAAG) by using a green, natural, and cheap biomass, chestnut tannin (CT), as a crosslinking agent, nano-silver particles (AgNPs) as an antimicrobial agent, aluminum trichloride (AlCl3) as a conducting medium, and the mixed water-glycerol as the solvent system. In this organohydrogel system, CT acted not only as the reducing and stabilizing agent for the preparation of antibacterial AgNPs but also as the crosslinking agent owing to its strong multiple hydrogen bonding interactions with PVA, realizing its multifunctional application. The PCAAG organohydrogel possessed outstanding physical and mechanical properties (350.54% of the maximum fracture strain and 1.55 MPa of the maximum tensile strength), considerable bacteriostatic effects against both Escherichia coli and Staphylococcus aureus, and excellent freeze resistance (it could function normally at -20 °C). The motion-monitoring sensor based on the PCAAG organohydrogel exhibited excellent specificity recognition for both large-amplitude (e.g., elbow bending, wrist bending, finger bending, running and walking, etc.) and small-amplitude (frowning and swallowing) human movements. The flexible keyboard constructed by using the PCAAG organohydrogel could easily achieve the transformation between digital signals and electrical signals, and the signal output had both specificity and stability. The velocity-monitoring sensor fabricated by using the PCAAG organohydrogel could accurately measure the speed of the object movement (less than 3% of relative error). In short, the present PCAAG organohydrogel solves the problems of the single application environment and a few application scenarios of traditional conductive hydrogels and possesses remarkable application potential as a multifunctional FSD in many fields such as artificial intelligence, sport management, soft robots, and human-computer interface.
Collapse
Affiliation(s)
- Bin Song
- Key Laboratory of Leather Chemistry and Engineering of Ministry of Education, Sichuan University, Chengdu610065, China
- National Engineering Research Center of Clean Technology in Leather Industry, Sichuan University, Chengdu610065, China
| | - Xin Fan
- Key Laboratory of Leather Chemistry and Engineering of Ministry of Education, Sichuan University, Chengdu610065, China
- National Engineering Research Center of Clean Technology in Leather Industry, Sichuan University, Chengdu610065, China
| | - Haibin Gu
- Key Laboratory of Leather Chemistry and Engineering of Ministry of Education, Sichuan University, Chengdu610065, China
- National Engineering Research Center of Clean Technology in Leather Industry, Sichuan University, Chengdu610065, China
| |
Collapse
|
23
|
Jing M, Zhou J, Zhang P, Hou D, Shen J, Tian J, Chen W. Porous AgNWs/Poly(vinylidene fluoride) Composite-Based Flexible Piezoresistive Sensor with High Sensitivity and Wide Pressure Ranges. ACS APPLIED MATERIALS & INTERFACES 2022; 14:55119-55129. [PMID: 36451588 DOI: 10.1021/acsami.2c17879] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Flexible piezoresistive sensors are highly desirable for tactile sensing and wearable electronics. However, the reported flexible piezoresistive sensors have the inherent trade-off effect between high sensitivity and wide pressure ranges. Herein, we report a flexible piezoresistive sensor with a three-dimensional (3D) porous microstructured sensing layer composed of silver nanowires (AgNWs) and a poly(vinylidene fluoride) (PVDF) matrix, exhibiting high sensitivity and wide pressure ranges. Benefiting from the conductive networks of AgNWs and the 3D porous structure of PVDF, the porous AgNWs/PVDF composite (PAPC)-based flexible piezoresistive sensor exhibits high sensitivities of 0.014 and 0.009 kPa-1 in the wide pressure ranges of 0-30 and 30-100 kPa, respectively. In addition, the fabricated sensor also shows a fast response time of 64 ms, a low detection limit of 25 Pa, and long-term durability over 10,000 continuous cycles. The PAPC-based flexible piezoresistive sensor can accurately monitor various human physiological activities (ranging from subtle deformations to vigorous body movements) by quantitatively measuring the tactile sensation on human skin. This work indicates that the proposed sensor can be potentially applicable to mobile healthcare monitoring devices as well as next-generation wearable electronics.
Collapse
Affiliation(s)
- Mengyuan Jing
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, P. R. China
| | - Jing Zhou
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, P. R. China
- Sanya Science and Education Innovation Park, Wuhan University of Technology, Sanya, Hainan 572025, P. R. China
| | - Pengchao Zhang
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, P. R. China
- Sanya Science and Education Innovation Park, Wuhan University of Technology, Sanya, Hainan 572025, P. R. China
| | - Dajun Hou
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, P. R. China
| | - Jie Shen
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, P. R. China
| | - Jing Tian
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, P. R. China
- Sanya Science and Education Innovation Park, Wuhan University of Technology, Sanya, Hainan 572025, P. R. China
| | - Wen Chen
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, School of Materials Science and Engineering, Wuhan University of Technology, Wuhan, Hubei 430070, P. R. China
| |
Collapse
|
24
|
Xu J, Wang H, Wen X, Wang S, Wang H. Mechanically Strong, Wet Adhesive, and Self-Healing Polyurethane Ionogel Enhanced with a Semi-interpenetrating Network for Underwater Motion Detection. ACS APPLIED MATERIALS & INTERFACES 2022; 14:54203-54214. [PMID: 36409304 DOI: 10.1021/acsami.2c15058] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
The gel-based sensors have developed rapidly in recent years toward multifunctionality. However, there are still some challenges that need to be solved, such as poor mechanical properties and inaccessibility to wet or water environments. To address these issues, we have developed an ionogel with a semi-interpenetrating network structure by adopting poly(vinylidene fluoride-co-hexafluoropropylene) as the linear non-cross-linked network, a double-bonded ionic liquid and double-bonded capped polyurethane as the cross-linked network, and an ionic liquid as the conductive media. The obtained ionogel exhibits tunable mechanical properties (3.67-8.76 MPa) and excellent sensing properties (IG-20, GF = 8.2). The superb environmental stability and self-healing properties of the ionogel were also demonstrated. Meanwhile, adhesion, self-healing, and sensing performance were guaranteed for underwater due to the presence of a large number of C-F bonds. We strongly believe that this ionogel with excellent mechanical properties and underwater communication is expected for monitoring the health of the human body and information transmission in the future.
Collapse
Affiliation(s)
- Junhuai Xu
- College of Biomass Science and Engineering, Sichuan University, Chengdu610065, P. R. China
| | - Hui Wang
- West China School of Basic Medical Sciences and Forensic Medicine, Sichuan University, Chengdu610041, P. R. China
| | - Xiao Wen
- College of Biomass Science and Engineering, Sichuan University, Chengdu610065, P. R. China
| | - Shuang Wang
- College of Biomass Science and Engineering, Sichuan University, Chengdu610065, P. R. China
- National Engineering Research Center of Clean Technology in Leather Industry, Sichuan University, Chengdu610065, P. R. China
| | - Haibo Wang
- College of Biomass Science and Engineering, Sichuan University, Chengdu610065, P. R. China
- National Engineering Research Center of Clean Technology in Leather Industry, Sichuan University, Chengdu610065, P. R. China
| |
Collapse
|
25
|
Liu D, Zhou H, Zhao Y, Huyan C, Wang Z, Torun H, Guo Z, Dai S, Xu BB, Chen F. A Strand Entangled Supramolecular PANI/PAA Hydrogel Enabled Ultra-Stretchable Strain Sensor. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2203258. [PMID: 36216591 DOI: 10.1002/smll.202203258] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 09/02/2022] [Indexed: 06/16/2023]
Abstract
Hydrogel electronics have attracted growing interest for emerging applications in personal healthcare management, human-machine interaction, etc. Herein, a "doping then gelling" strategy to synthesize supramolecular PANI/PAA hydrogel with a specific strand entangled network is proposed, by doping the PANI with acrylic acid (AA) monomers to avoid PANI aggregation. The high-density electrostatic interaction between PAA and PANI chains serves as a dynamic bond to initiate the strand entanglement, enabling PAA/PANI hydrogel with ultra-stretchability (2830%), high breaking strength (120 kPa), and rapid self-healing properties. Moreover, the PAA/PANI hydrogel-based sensor with a high strain sensitivity (gauge factor = 12.63), a rapid responding time (222 ms), and a robust conductivity-based sensing behavior under cyclic stretching is developed. A set of strain sensing applications to precisely monitor human movements is also demonstrated, indicating a promising application prospect as wearable devices.
Collapse
Affiliation(s)
- Dong Liu
- School of Chemical Engineering and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Honghao Zhou
- Mechanical and Construction Engineering, Faculty of Engineering and Environment, Northumbria University, Newcastle upon Tyne, NE1 8ST, UK
| | - Yuanyuan Zhao
- School of Chemical Engineering and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- The 41 st Institute of the Forth Academy, China Aerospace Science and Technology Corporation, Xi'an, 710025, P. R. China
| | - Chenxi Huyan
- School of Chemical Engineering and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Zibi Wang
- School of Chemical Engineering and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Hamdi Torun
- Mechanical and Construction Engineering, Faculty of Engineering and Environment, Northumbria University, Newcastle upon Tyne, NE1 8ST, UK
| | - Zhanhu Guo
- Mechanical and Construction Engineering, Faculty of Engineering and Environment, Northumbria University, Newcastle upon Tyne, NE1 8ST, UK
| | - Sheng Dai
- School of Chemical and Process Engineering, University of Leeds, Leeds, LS2 9JT, UK
| | - Ben Bin Xu
- Mechanical and Construction Engineering, Faculty of Engineering and Environment, Northumbria University, Newcastle upon Tyne, NE1 8ST, UK
| | - Fei Chen
- School of Chemical Engineering and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| |
Collapse
|
26
|
He Z, Zhou Z, Yuan W. Highly Adhesive, Stretchable, and Antifreezing Hydrogel with Excellent Mechanical Properties for Sensitive Motion Sensors and Temperature-/Humidity-Driven Actuators. ACS APPLIED MATERIALS & INTERFACES 2022; 14:38205-38215. [PMID: 35952384 DOI: 10.1021/acsami.2c10292] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Conductive hydrogels as flexible wearable devices have attracted considerable attention due to their mechanical flexibility and intelligent sensing. How to endow more and better performance, such as high self-adhesion, stretchability, and wide application temperature range for traditional hydrogels and flexible sensors is a challenge. Herein, a stretchable, self-adhesive, and antifreezing conductive hydrogel with multiple networks and excellent mechanical properties was prepared by a two-step method for its application in sensitive motion sensors and temperature-/humidity-driven actuators. First, quaternary chitosan (QCS) was introduced into the network of an acrylamide (AM) and 1-vinyl imidazole (VI) copolymer initiated by UV-photoinitiated radical polymerization. Then, the double-network hydrogel was immersed in a FeCl3 solution to fabricate the P(AAm-co-VI)/QCS-Fe3+ ionic hydrogel with multiple physical networks. The properties of the hydrogel were controllable and adjustable. The toughness of the ionic hydrogel could reach up to 654.4 kJ/m3, the fracture strength could reach 253.1 kPa, and the compressive strength reached 8.4 MPa at an 80% compression strain. The multiple physical networks improved the mechanical properties and the quick resilience of the hydrogel. A large amount of FeCl3 in the network greatly enhanced the ionic conductivity. Meanwhile, hydrogen bonds with water molecules inhibit the formation of ice crystals between zero water molecules and enhance the freezing resistance of P(Aam-co-VI)/QCS hydrogels. The active group on the QCS chain provided adhesiveness to various substrates for hydrogels. The P(AAm-co-VI)/QCS-Fe3+ hydrogel-based sensor showed high sensitivity, which can detect human movement and pulse, with a gauge factor of 2.37. Finally, due to the different dehydration rates of the P(AAm-co-VI)/QCS-Fe3+ and P(AAm-co-VI)/QCS hydrogel, a double-layer temperature/humidity-driven actuator was fabricated, expanding the application of conductive hydrogels.
Collapse
Affiliation(s)
- Zhirui He
- Department of Interventional and Vascular Surgery, Shanghai Tenth People's Hospital, School of Materials Science and Engineering, Tongji University, Shanghai 201804, People's Republic of China
| | - Zixuan Zhou
- Department of Interventional and Vascular Surgery, Shanghai Tenth People's Hospital, School of Materials Science and Engineering, Tongji University, Shanghai 201804, People's Republic of China
| | - Weizhong Yuan
- Department of Interventional and Vascular Surgery, Shanghai Tenth People's Hospital, School of Materials Science and Engineering, Tongji University, Shanghai 201804, People's Republic of China
| |
Collapse
|
27
|
Chu Z, Li G, Gong X, Zhao Z, Tan Y, Jiang Z. Hierarchical Wrinkles for Tunable Strain Sensing Based on Programmable, Anisotropic, and Patterned Graphene Hybrids. Polymers (Basel) 2022; 14:polym14142800. [PMID: 35890576 PMCID: PMC9322441 DOI: 10.3390/polym14142800] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 12/18/2022] Open
Abstract
Flexible, stretchable, wearable, and stable electronic materials are widely studied, owing to their applications in wearable devices and the Internet of Things. Because of the demands for both strain-insensitive resistors and high gauge factor (GF) strain-sensitive materials, anisotropic strain sensitivity has been an important aspect of electronic materials. In addition, the materials should have adjustable strain sensitivities. In this work, such properties are demonstrated in reduced graphene oxide (RGO) with hierarchical oriented wrinkle microstructures, generated using the two-step shrinkage of a rubber substrate. The GF values range from 0.15 to 28.32 at 100% strain. For device demonstrations, macrostructure patterns are designed to prepare patterned wrinkling graphene at rubber substrate (PWG@R). Serpentiform curves can be used for the constant-value resistor, combined with the first-grade wrinkles. Strip lines can increase the strain-sensing property, along with the second-grade wrinkles. The patterned sensor exhibits improved GF values range from 0.05 to 49.5. The assembled sensor shows an excellent stability (>99% retention after 600 cycles) with a high GF (49.5). It can monitor the vital signs of the throat and wrist and sense large motions of fingers. Thus, PWG@R-based strain sensors have great potential in various health or motion monitoring fields.
Collapse
|
28
|
Atta A, Alotaibi B, Abdelhamied M. Structural characteristics and optical properties of methylcellulose/polyaniline films modified by low energy oxygen irradiation. INORG CHEM COMMUN 2022. [DOI: 10.1016/j.inoche.2022.109502] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
29
|
Guo X, Li J, Wang F, Zhang J, Zhang J, Shi Y, Pan L. Application of conductive polymer hydrogels in flexible electronics. JOURNAL OF POLYMER SCIENCE 2022. [DOI: 10.1002/pol.20210933] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Xin Guo
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering Nanjing University Nanjing Jiangsu China
| | - Jiean Li
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering Nanjing University Nanjing Jiangsu China
| | - Fanyu Wang
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering Nanjing University Nanjing Jiangsu China
| | - Jia‐Han Zhang
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering Nanjing University Nanjing Jiangsu China
| | - Jing Zhang
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering Nanjing University Nanjing Jiangsu China
| | - Yi Shi
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering Nanjing University Nanjing Jiangsu China
| | - Lijia Pan
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering Nanjing University Nanjing Jiangsu China
| |
Collapse
|
30
|
Liu Y, Li H, Feng Q, Su H, Li D, Shang Y, Chen H, Li B, Dong H. A Three-Dimensional-Printed Recyclable, Flexible, and Wearable Device for Visualized UV, Temperature, and Sweat pH Sensing. ACS OMEGA 2022; 7:9834-9845. [PMID: 35350374 PMCID: PMC8945124 DOI: 10.1021/acsomega.2c00128] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 02/21/2022] [Indexed: 05/08/2023]
Abstract
Wearable devices are now recognized as a powerful tool to collect physiological and environmental information in a smart, noninvasive, and real-time manner. Despite the rapid progress of wearable devices especially wearable electronic devices, there are still several challenges that limit their further development, for example, a complicated electrical signal acquisition and processing process to eliminate the interference from the surrounding signals, bulky power supply, inevitable e-waste, and environmental pollution. Herein, we report a 3D-printed recyclable, flexible, and wearable device for visualized UV, temperature, and sweat pH sensing. Compared with wearable electronic devices, our visualized wearable device senses environmental (UV light, ambient temperature), biophysical (skin temperature), and biochemical (sweat pH) signals via stimuli-responsive color change, which does not require complicated electronic circuit design/assembly, time-consuming data processing and additional power source. In addition, this visualized wearable device is fabricated via a 3D support bath printing technology by printing UV-, temperature-, and sweat pH-sensing inks containing photochromic, thermochromic, and pH-chromic materials, respectively, into/onto sustainable starch solution, resulting in a multi-functional, recyclable, and flexible sensing device with high reproducibility. Our results reveal that UV light intensities under sunlight (0-2500 μW/cm2), ambient, and skin temperatures (0-38 °C) as well as sweat pH (4.0-7.0) can be successfully monitored.
Collapse
Affiliation(s)
- Yang Liu
- Department
of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China
- National
Engineering Research Center for Tissue Restoration and Reconstruction
(NERC-TRR), Guangzhou 510006, China
| | - Haofei Li
- Department
of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China
- Key
Laboratory of Biomedical Materials and Engineering of the Ministry
of Education, South China University of
Technology, Guangzhou 510006, China
| | - Qi Feng
- Department
of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China
- Guangdong
Province Key Laboratory of Biomedical Engineering, South China University of Technology, Guangzhou 510641, China
| | - Hongxian Su
- Department
of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China
- National
Engineering Research Center for Tissue Restoration and Reconstruction
(NERC-TRR), Guangzhou 510006, China
| | - Dingguo Li
- Department
of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China
- National
Engineering Research Center for Tissue Restoration and Reconstruction
(NERC-TRR), Guangzhou 510006, China
| | - Yulian Shang
- Department
of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China
- Key
Laboratory of Biomedical Materials and Engineering of the Ministry
of Education, South China University of
Technology, Guangzhou 510006, China
| | - Hongjie Chen
- Department
of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China
- National
Engineering Research Center for Tissue Restoration and Reconstruction
(NERC-TRR), Guangzhou 510006, China
| | - Bingrui Li
- Department
of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China
- Key
Laboratory of Biomedical Materials and Engineering of the Ministry
of Education, South China University of
Technology, Guangzhou 510006, China
| | - Hua Dong
- Department
of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510006, China
- National
Engineering Research Center for Tissue Restoration and Reconstruction
(NERC-TRR), Guangzhou 510006, China
- Key
Laboratory of Biomedical Materials and Engineering of the Ministry
of Education, South China University of
Technology, Guangzhou 510006, China
- Guangdong
Province Key Laboratory of Biomedical Engineering, South China University of Technology, Guangzhou 510641, China
| |
Collapse
|
31
|
Zhang J, Zhang Q, Liu X, Xia S, Gao Y, Gao G. Flexible and wearable strain sensors based on conductive hydrogels. JOURNAL OF POLYMER SCIENCE 2022. [DOI: 10.1002/pol.20210935] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Jiawei Zhang
- Polymeric and Soft Materials Laboratory, School of Chemical Engineering and Advanced Institute of Materials Science Changchun University of Technology Changchun China
| | - Qin Zhang
- Polymeric and Soft Materials Laboratory, School of Chemical Engineering and Advanced Institute of Materials Science Changchun University of Technology Changchun China
| | - Xin Liu
- Polymeric and Soft Materials Laboratory, School of Chemical Engineering and Advanced Institute of Materials Science Changchun University of Technology Changchun China
| | - Shan Xia
- Polymeric and Soft Materials Laboratory, School of Chemical Engineering and Advanced Institute of Materials Science Changchun University of Technology Changchun China
| | - Yang Gao
- Polymeric and Soft Materials Laboratory, School of Chemical Engineering and Advanced Institute of Materials Science Changchun University of Technology Changchun China
| | - Guanghui Gao
- Polymeric and Soft Materials Laboratory, School of Chemical Engineering and Advanced Institute of Materials Science Changchun University of Technology Changchun China
| |
Collapse
|
32
|
Veeramuthu L, Venkatesan M, Benas JS, Cho CJ, Lee CC, Lieu FK, Lin JH, Lee RH, Kuo CC. Recent Progress in Conducting Polymer Composite/Nanofiber-Based Strain and Pressure Sensors. Polymers (Basel) 2021; 13:4281. [PMID: 34960831 PMCID: PMC8705576 DOI: 10.3390/polym13244281] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 12/01/2021] [Accepted: 12/01/2021] [Indexed: 01/11/2023] Open
Abstract
The Conducting of polymers belongs to the class of polymers exhibiting excellence in electrical performances because of their intrinsic delocalized π- electrons and their tunability ranges from semi-conductive to metallic conductive regime. Conducting polymers and their composites serve greater functionality in the application of strain and pressure sensors, especially in yielding a better figure of merits, such as improved sensitivity, sensing range, durability, and mechanical robustness. The electrospinning process allows the formation of micro to nano-dimensional fibers with solution-processing attributes and offers an exciting aspect ratio by forming ultra-long fibrous structures. This review comprehensively covers the fundamentals of conducting polymers, sensor fabrication, working modes, and recent trends in achieving the sensitivity, wide-sensing range, reduced hysteresis, and durability of thin film, porous, and nanofibrous sensors. Furthermore, nanofiber and textile-based sensory device importance and its growth towards futuristic wearable electronics in a technological era was systematically reviewed to overcome the existing challenges.
Collapse
Affiliation(s)
- Loganathan Veeramuthu
- Institute of Organic and Polymeric Materials, Research and Development Center of Smart Textile Technology, National Taipei University of Technology, Taipei 10608, Taiwan; (L.V.); (M.V.); (J.-S.B.)
| | - Manikandan Venkatesan
- Institute of Organic and Polymeric Materials, Research and Development Center of Smart Textile Technology, National Taipei University of Technology, Taipei 10608, Taiwan; (L.V.); (M.V.); (J.-S.B.)
| | - Jean-Sebastien Benas
- Institute of Organic and Polymeric Materials, Research and Development Center of Smart Textile Technology, National Taipei University of Technology, Taipei 10608, Taiwan; (L.V.); (M.V.); (J.-S.B.)
| | - Chia-Jung Cho
- Institute of Organic and Polymeric Materials, Research and Development Center of Smart Textile Technology, National Taipei University of Technology, Taipei 10608, Taiwan; (L.V.); (M.V.); (J.-S.B.)
| | - Chia-Chin Lee
- Department of Physical Medicine and Rehabilitation, Cheng Hsin General Hospital, Taipei 11220, Taiwan;
| | - Fu-Kong Lieu
- Department of Physical Medicine and Rehabilitation, Cheng Hsin General Hospital, Taipei 11220, Taiwan;
- Department of Physical Medicine and Rehabilitation, National Defense Medical Center, Taipei 11490, Taiwan
| | - Ja-Hon Lin
- Institute of Electro-Optical Engineering, National Taipei University of Technology, Taipei 10608, Taiwan;
| | - Rong-Ho Lee
- Department of Chemical Engineering, National Chung Hsing University, Taichung 40227, Taiwan;
| | - Chi-Ching Kuo
- Institute of Organic and Polymeric Materials, Research and Development Center of Smart Textile Technology, National Taipei University of Technology, Taipei 10608, Taiwan; (L.V.); (M.V.); (J.-S.B.)
| |
Collapse
|