1
|
Chinnappan R, Mir TA, Alsalameh S, Makhzoum T, Alzhrani A, Al-Kattan K, Yaqinuddin A. Low-Cost Point-of-Care Monitoring of ALT and AST Is Promising for Faster Decision Making and Diagnosis of Acute Liver Injury. Diagnostics (Basel) 2023; 13:2967. [PMID: 37761334 PMCID: PMC10529728 DOI: 10.3390/diagnostics13182967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 06/28/2023] [Accepted: 06/30/2023] [Indexed: 09/29/2023] Open
Abstract
Alanine aminotransferase (ALT) and aspartate aminotransferase (AST) are important liver enzymes in clinical settings. Their levels are known to be elevated in individuals with underlying liver diseases and those consuming hepatotoxic drugs. Serum ALT and AST levels are crucial for diagnosing and assessing liver diseases. Serum ALT is considered the most reliable and specific candidate as a disease biomarker for liver diseases. ALT and AST levels are routinely analyzed in high-risk individuals for the bioanalysis of both liver function and complications associated with drug-induced liver injury. Typically, ALT and AST require blood sampling, serum separation, and testing. Traditional methods require expensive or sophisticated equipment and trained specialists, which is often time-consuming. Therefore, developing countries have limited or no access to these methods. To address the above issues, we hypothesize that low-cost biosensing methods (paper-based assays) can be applied to the analysis of ALT and AST levels in biological fluids. The paper-based biodetection technique can semi-quantitatively measure ALT and AST from capillary finger sticks, and it will pave the way for the development of an inexpensive and rapid alternative method for the early detection and diagnosis of liver diseases. This method is expected to significantly reduce the economic burden and aid routine clinical analysis in both developed and underdeveloped countries. The development of low-cost testing platforms and their diagnostic utility will be extremely beneficial in helping millions of patients with liver disorders.
Collapse
Affiliation(s)
- Raja Chinnappan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (S.A.); (T.M.); (A.A.); (K.A.-K.)
- Tissue/Organ Bioengineering & BioMEMS Lab, Organ Transplant Centre of Excellence, Transplant Research & Innovation Department, King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Tanveer Ahmad Mir
- Tissue/Organ Bioengineering & BioMEMS Lab, Organ Transplant Centre of Excellence, Transplant Research & Innovation Department, King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Suliman Alsalameh
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (S.A.); (T.M.); (A.A.); (K.A.-K.)
| | - Tariq Makhzoum
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (S.A.); (T.M.); (A.A.); (K.A.-K.)
| | - Alaa Alzhrani
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (S.A.); (T.M.); (A.A.); (K.A.-K.)
- Tissue/Organ Bioengineering & BioMEMS Lab, Organ Transplant Centre of Excellence, Transplant Research & Innovation Department, King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
- Medical Laboratory Technology Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Khaled Al-Kattan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (S.A.); (T.M.); (A.A.); (K.A.-K.)
| | - Ahmed Yaqinuddin
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (S.A.); (T.M.); (A.A.); (K.A.-K.)
| |
Collapse
|
2
|
Tokihiro JC, Tu WC, Berthier J, Lee JJ, Dostie AM, Khor JW, Eakman M, Theberge AB, Berthier E. Enhanced capillary pumping using open-channel capillary trees with integrated paper pads. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2023; 35:082120. [PMID: 37675268 PMCID: PMC10479884 DOI: 10.1063/5.0157801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 07/20/2023] [Indexed: 09/08/2023]
Abstract
The search for efficient capillary pumping has led to two main directions for investigation: first, assembly of capillary channels to provide high capillary pressures, and second, imbibition in absorbing fibers or paper pads. In the case of open microfluidics (i.e., channels where the top boundary of the fluid is in contact with air instead of a solid wall), the coupling between capillary channels and paper pads unites the two approaches and provides enhanced capillary pumping. In this work, we investigate the coupling of capillary trees-networks of channels mimicking the branches of a tree-with paper pads placed at the extremities of the channels, mimicking the small capillary networks of leaves. It is shown that high velocities and flow rates (7 mm/s or 13.1 μl/s) for more than 30 s using 50% (v/v) isopropyl alcohol, which has a 3-fold increase in viscosity in comparison to water; 6.5 mm/s or 12.1 μl/s for more than 55 s with pentanol, which has a 3.75-fold increase in viscosity in comparison to water; and >3.5 mm/s or 6.5 μl/s for more than 150 s with nonanol, which has a 11-fold increase in viscosity in comparison to water, can be reached in the root channel, enabling higher sustained flow rates than that of capillary trees alone.
Collapse
Affiliation(s)
- Jodie C. Tokihiro
- Department of Chemistry, University of Washington, Seattle, Washington 98195, USA
| | - Wan-chen Tu
- Department of Chemistry, University of Washington, Seattle, Washington 98195, USA
| | - Jean Berthier
- Department of Chemistry, University of Washington, Seattle, Washington 98195, USA
| | - Jing J. Lee
- Department of Chemistry, University of Washington, Seattle, Washington 98195, USA
| | - Ashley M. Dostie
- Department of Chemistry, University of Washington, Seattle, Washington 98195, USA
| | - Jian Wei Khor
- Department of Chemistry, University of Washington, Seattle, Washington 98195, USA
| | - Madeleine Eakman
- Department of Chemistry, University of Washington, Seattle, Washington 98195, USA
| | | | - Erwin Berthier
- Department of Chemistry, University of Washington, Seattle, Washington 98195, USA
| |
Collapse
|
3
|
Park NH, Kim J, Ahn Y. Fabric-based self-pumping, single-stream microfluidic fuel cell. Electrochim Acta 2023. [DOI: 10.1016/j.electacta.2023.142106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
|
4
|
Saiboh T, Malahom N, Prakobkij A, Seebunrueng K, Amatatongchai M, Chairam S, Sameenoi Y, Jarujamrus P. Visual detection of formalin in food samples by using a microfluidic thread-based analytical device. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
|
5
|
Chen L, Ghiasvand A, Paull B. Applications of thread-based microfluidics: Approaches and options for detection. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
|
6
|
Parween S, Asthana A, Nahar P. Fundamentals of Image-Based Assay (IBA) System for Affordable Point of Care Diagnostics. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
7
|
Damodara S, Arora J, Liaw PC, Fox-Robichaud AE, Selvaganapathy PR. Single-step measurement of cell-free DNA for sepsis prognosis using a thread-based microfluidic device. Mikrochim Acta 2022; 189:146. [PMID: 35298718 DOI: 10.1007/s00604-022-05245-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 02/22/2022] [Indexed: 10/18/2022]
Abstract
Cell-free DNA (cfDNA) content in plasma has been studied as a biomarker for sepsis. Recent publications show that the cfDNA content in sepsis patients entering intensive care unit who were likely to survive had a total cfDNA concentration of 1.16 ± 0.13 μg/mL compared to 4.65 ± 0.48 μg/mL of non-survivors. Current methods for measuring cfDNA content in plasma were designed to amplify and measure low concentrations of specific DNA, making them unsuitable for low-cost measurement of total cfDNA content in plasma. Here, we have developed a point of care (POC) device that uses a thread silicone device as a medium to store a fluorescent dye which eliminates the need for preparatory steps, external aliquoting and dispensing of reagents, preconcentration, and external mixing while reducing the detection cost. The device was paired with a portable imaging system with an excitation filter at 472 ± 10 nm and an emission filter of 520 ± 10 nm that can be operated with just 100 mA current supply. The device was demonstrated for use in the quantification of buffered cfDNA samples in a range 1-6 μg/mL with a sensitivity of 5.72 AU/μg/mL and with cfDNA spiked in plasma with a range of 1-3 μg/mL and a sensitivity of 5.43 AU/μg/mL. The results showed that the device could be used as a low-cost, rapid, and portable POC device for differentiating between survivors and non-survivors of sepsis within 20 min.
Collapse
Affiliation(s)
- Sreekant Damodara
- Department of Mechanical Engineering, McMaster University, Hamilton, Canada
| | - Jaskirat Arora
- Department of Medicine, McMaster University, Hamilton, Canada
| | - Patricia C Liaw
- Department of Medicine, McMaster University, Hamilton, Canada
| | | | | | | |
Collapse
|
8
|
Yue H, Zeng Q, Huang J, Guo Z, Liu W. Fog collection behavior of bionic surface and large fog collector: A review. Adv Colloid Interface Sci 2022; 300:102583. [PMID: 34954474 DOI: 10.1016/j.cis.2021.102583] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2021] [Revised: 12/11/2021] [Accepted: 12/14/2021] [Indexed: 11/18/2022]
Abstract
Water shortages are currently becoming more and more serious due to complicated factors such as the development of the economy, environmental pollution, and climate deterioration. And it is the best solution to the problems faced by people in today's world to investigate the bionic structure of nature and explore effective methods for fog collection. Herein, we've illustrated the bionic structures of the Namib desert beetle, cactus spines, and spider silk, and we imitate and further modify the respective bionic structures, as well as construct multifunctional bionic structures to improve fog collection. In addition, we also expound the fog collection behavior of a large fog collector, and an excellent fog capture effect was achieved through studying the mesh structure, the surface modification of the mesh, and the construction of the fog collector. The advantages and limitations of fog collection by a harp fog collector were also explored. We hope that through this review, relevant researchers can have a deeper understanding of this field and thus promote the development of fog collection.
Collapse
Affiliation(s)
- Hao Yue
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China
| | - Qinghong Zeng
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China
| | - Jinxia Huang
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China.
| | - Zhiguang Guo
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China.
| | - Weimin Liu
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China
| |
Collapse
|
9
|
Hasandka A, Singh AR, Prabhu A, Singhal HR, Nandagopal MSG, Mani NK. Paper and thread as media for the frugal detection of urinary tract infections (UTIs). Anal Bioanal Chem 2022; 414:847-865. [PMID: 34668042 PMCID: PMC8724062 DOI: 10.1007/s00216-021-03671-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/02/2021] [Accepted: 09/15/2021] [Indexed: 12/22/2022]
Abstract
Urinary tract infections (UTIs) make up a significant proportion of the global burden of disease in vulnerable groups and tend to substantially impair the quality of life of those affected, making timely detection of UTIs a priority for public health. However, economic and societal barriers drastically reduce accessibility of traditional lab-based testing methods for critical patient groups in low-resource areas, negatively affecting their overall healthcare outcomes. As a result, cellulose-based materials such as paper and thread have garnered significant interest among researchers as substrates for so-called frugal analytical devices which leverage the material's portability and adaptability for facile and reproducible diagnoses of UTIs. Although the field may be only in its infancy, strategies aimed at commercial penetration can appreciably increase access to more healthcare options for at-risk people. In this review, we catalogue recent advances in devices that use cellulose-based materials as the primary housing or medium for UTI detection and chart out trends in the field. We also explore different modalities employed for detection, with particular emphasis on their ability to be ported onto discreet casings such as sanitary products.
Collapse
Affiliation(s)
- Amrutha Hasandka
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Ankita Ramchandran Singh
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Anusha Prabhu
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Hardik Ramesh Singhal
- Department of Chemical Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - M S Giri Nandagopal
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, Kharagpur, 721302, India
| | - Naresh Kumar Mani
- Microfluidics, Sensors and Diagnostics Laboratory (μSenD), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
| |
Collapse
|
10
|
Chen H, Liu Y, Feng S, Cao Y, Wu T, Liu Z. Cotton thread-based multi-channel photothermal biosensor for simultaneous detection of multiple microRNAs. Biosens Bioelectron 2021; 200:113913. [PMID: 34968855 DOI: 10.1016/j.bios.2021.113913] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/15/2021] [Accepted: 12/21/2021] [Indexed: 02/07/2023]
Abstract
The abnormal expression of microRNAs (miRNAs) is associated with various diseases. Developing simple and portable methods for sensitive, rapid and simultaneous detection of multiple miRNAs is critical to achieve accurate and timely diagnosis. Herein, a cotton thread-based multi-channel photothermal biosensor was proposed for simultaneous detection of three breast cancer-related miRNAs including miRNA-10b, miRNA-27a and miRNA-let-7a. Three cotton thread-based channels with one input were designed and the capture probes for detecting different miRNAs were immobilized on the test zones of the corresponding channels. Cu2-xS nanostrings prepared on the basis of hybridization chain reaction (HCR) were taken as the photothermal agents for signal transduction and amplification. The formation of a sandwich structure among the capture probe, target miRNA, and Cu2-xS nanostrings led to the accumulation of the Cu2-xS nanostrings on the test zones and transformed the concentration of miRNA into temperature signal under 808 nm laser irradiation. The temperature changes were quantified by a portable thermal camera and directly reflected the concentration of miRNAs. Under the optimal conditions, the developed multi-channel photothermal biosensor showed excellent specificity and sensitivity with the detection limits of 37 pM, 38 pM and 38 pM for miRNA-10b, miRNA-27a and miRNA-let-7a, respectively. Furthermore, a simultaneous detection of the three miRNAs in cell lysates were achieved and the results were in accordance with that obtained by the quantitative reverse transcription polymerase chain reaction (qRT-PCR), indicating its excellent capacity for practical applications. The developed biosensor provided an important tool for analysis of multiple targets and showed great potential in clinical diagnosis.
Collapse
Affiliation(s)
- Hanjun Chen
- College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China
| | - Ying Liu
- College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China
| | - Shaoqiong Feng
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, PR China
| | - Yu Cao
- College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China
| | - Tingting Wu
- College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China.
| | - Zhihong Liu
- College of Chemistry and Chemical Engineering, Hubei University, Wuhan, 430062, PR China; College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, PR China
| |
Collapse
|
11
|
Piper A, Öberg Månsson I, Khaliliazar S, Landin R, Hamedi MM. A disposable, wearable, flexible, stitched textile electrochemical biosensing platform. Biosens Bioelectron 2021; 194:113604. [PMID: 34488171 DOI: 10.1016/j.bios.2021.113604] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 08/25/2021] [Accepted: 08/28/2021] [Indexed: 11/30/2022]
Abstract
Wearable sensors are a fast growing and exciting research area, the success of smart watches are a great example of the utility and demand for wearable sensing systems. The current state of the art routinely uses expensive and bulky equipment designed for long term use. There is a need for cheap and disposable wearable sensors to make single use measurements, primarily in the area of biomarker detection. Herein we report the ability to make cheap (0.22 USD/sensor), disposable, wearable sensors by stitching conductive gold coated threads into fabrics. These threads are easily functionalised with thiolate self-assembled monolayers which can be designed for the detection of a broad range of different biomarkers. This all textile sensing platform is ideally suited to be scaled up and has the added advantage of being stretchable with insignificant effect on the electrochemistry of the devices. As a proof of principle, the devices have been functionalised with a continuous glucose sensing system which was able to detect glucose in human sweat across the clinically relevant range (0.1-0.6 mM). The sensors have a sensitivity of 126 ± 14 nA/mM of glucose and a limit of detection of 301 ± 2 nM. This makes them ideally suited for biomarker detection in point-of-care sensing applications.
Collapse
Affiliation(s)
- Andrew Piper
- Department of Fibre and Polymer Technology, KTH Royal Institute of Technology, Teknikringen 56, Stockholm, 10044, Sweden.
| | - Ingrid Öberg Månsson
- Department of Fibre and Polymer Technology, KTH Royal Institute of Technology, Teknikringen 56, Stockholm, 10044, Sweden
| | - Shirin Khaliliazar
- Department of Fibre and Polymer Technology, KTH Royal Institute of Technology, Teknikringen 56, Stockholm, 10044, Sweden
| | - Roman Landin
- Department of Fibre and Polymer Technology, KTH Royal Institute of Technology, Teknikringen 56, Stockholm, 10044, Sweden
| | - Mahiar Max Hamedi
- Department of Fibre and Polymer Technology, KTH Royal Institute of Technology, Teknikringen 56, Stockholm, 10044, Sweden.
| |
Collapse
|
12
|
Agustini D, Caetano FR, Quero RF, Fracassi da Silva JA, Bergamini MF, Marcolino-Junior LH, de Jesus DP. Microfluidic devices based on textile threads for analytical applications: state of the art and prospects. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:4830-4857. [PMID: 34647544 DOI: 10.1039/d1ay01337h] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microfluidic devices based on textile threads have interesting advantages when compared to systems made with traditional materials, such as polymers and inorganic substrates (especially silicon and glass). One of these significant advantages is the device fabrication process, made more cheap and simple, with little or no microfabrication apparatus. This review describes the fundamentals, applications, challenges, and prospects of microfluidic devices fabricated with textile threads. A wide range of applications is discussed, integrated with several analysis methods, such as electrochemical, colorimetric, electrophoretic, chromatographic, and fluorescence. Additionally, the integration of these devices with different substrates (e.g., 3D printed components or fabrics), other devices (e.g., smartphones), and microelectronics is described. These combinations have allowed the construction of fully portable devices and consequently the development of point-of-care and wearable analytical systems.
Collapse
Affiliation(s)
- Deonir Agustini
- Laboratory of Electrochemical Sensors (LABSENSE), Federal University of Paraná (UFPR), Curitiba, PR, Brazil.
| | - Fábio Roberto Caetano
- Laboratory of Electrochemical Sensors (LABSENSE), Federal University of Paraná (UFPR), Curitiba, PR, Brazil.
| | - Reverson Fernandes Quero
- Institute of Chemistry, State University of Campinas (Unicamp), Campinas, SP, 13083-861, Brazil.
| | - José Alberto Fracassi da Silva
- Institute of Chemistry, State University of Campinas (Unicamp), Campinas, SP, 13083-861, Brazil.
- Instituto Nacional de Ciência e Tecnologia em Bioanalítica (INCTBio), Campinas, SP, Brazil
| | - Márcio Fernando Bergamini
- Laboratory of Electrochemical Sensors (LABSENSE), Federal University of Paraná (UFPR), Curitiba, PR, Brazil.
| | | | - Dosil Pereira de Jesus
- Institute of Chemistry, State University of Campinas (Unicamp), Campinas, SP, 13083-861, Brazil.
- Instituto Nacional de Ciência e Tecnologia em Bioanalítica (INCTBio), Campinas, SP, Brazil
| |
Collapse
|
13
|
Khan JU, Ruland A, Sayyar S, Paull B, Chen J, Innis PC. Wireless bipolar electrode-based textile electrofluidics: towards novel micro-total-analysis systems. LAB ON A CHIP 2021; 21:3979-3990. [PMID: 34636814 DOI: 10.1039/d1lc00538c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Point of care testing using micro-total-analysis systems (μTAS) is critical to emergent healthcare devices with rapid and robust responses. However, two major barriers to the success of this approach are the prohibitive cost of microchip fabrication and poor sensitivity due to small sample volumes in a microfluidic format. Here, we aimed to replace the complex microchip format with a low-cost textile substrate with inherently built microchannels using the fibers' spaces. Secondly, by integrating this textile-based microfluidics with electrophoresis and wireless bipolar electrochemistry, we can significantly improve solute detection by focusing and concentrating the analytes of interest. Herein, we demonstrated that an in situ metal electrode simply inserted inside the textile-based electrophoretic system can act as a wireless bipolar electrode (BPE) that generates localized electric field and pH gradients adjacent to the BPE and extended along the length of the textile construct. As a result, charged analytes were not only separated electrophoretically but also focused where their electrophoretic migration and counter flow (EOF) balances due to redox reactions proceeding at the BPE edges. The developed wireless redox focusing technique on textile constructs was shown to achieve a 242-fold enrichment of anionically charged solute over an extended time of 3000 s. These findings suggest a simple route that achieves separation and analyte focusing on low-cost surface-accessible inverted substrates, which is far simpler than the more complex ITP on conventional closed and inaccessible capillary channels.
Collapse
Affiliation(s)
- Jawairia Umar Khan
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, University of Wollongong, Innovation Campus, New South Wales 2500, Australia.
- Department of Fibre and Textile Technology, University of Agriculture, Faisalabad 38000, Pakistan
| | - Andres Ruland
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, University of Wollongong, Innovation Campus, New South Wales 2500, Australia.
| | - Sepidar Sayyar
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, University of Wollongong, Innovation Campus, New South Wales 2500, Australia.
- Australian National Fabrication Facility - Materials Node, University of Wollongong, Innovation Campus, New South Wales 2500, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS) and, ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7005, Australia
| | - Jun Chen
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, University of Wollongong, Innovation Campus, New South Wales 2500, Australia.
| | - Peter C Innis
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, University of Wollongong, Innovation Campus, New South Wales 2500, Australia.
- Australian National Fabrication Facility - Materials Node, University of Wollongong, Innovation Campus, New South Wales 2500, Australia
| |
Collapse
|
14
|
KUMADA R, ORIOKA M, CITTERIO D, HIRUTA Y. Fluorescent and Bioluminescent Probes based on Precise Molecular Design. BUNSEKI KAGAKU 2021. [DOI: 10.2116/bunsekikagaku.70.601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Rei KUMADA
- Department of Applied Chemistry, Keio University
| | | | | | - Yuki HIRUTA
- Department of Applied Chemistry, Keio University
| |
Collapse
|
15
|
Kimani MK, Mwangi J, Goluch ED. Electrophoresis on a polyester thread coupled with an end-channel pencil electrode detector. Electrophoresis 2021; 42:1974-1982. [PMID: 34333778 DOI: 10.1002/elps.202100108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Revised: 07/05/2021] [Accepted: 07/27/2021] [Indexed: 11/07/2022]
Abstract
We present the design and characterization of a low cost, thread-based electrophoretic device with integrated electrochemical detection. The device has an end-channel pencil graphite electrode placement system for performing electrochemical detection on the thread electrophoresis platform with direct sample pipetting onto the thread. We also established the use of methylene blue and neutral red as a pair of reference migration markers for separation techniques coupled with electrochemical detection, as they have different colors for visual analysis and are both electroactive. Importantly, neutral red was also found to migrate at a similar rate to the EOF, indicating that it can be used as a visual identifier of EOF. The utility of our system was demonstrated by electrophoretic separation and electrochemical detection of physiologically relevant concentrations of pyocyanin in a solution containing multiple electroactive compounds. Pyocyanin is a biomarker for the detection of pathogenic Pseudomonas aeruginosa and has a redox potential that is similar to that of methylene blue. The system was able to effectively resolve methylene blue, neutral red, and pyocyanin in less than 7 min of electrophoretic separation. The theoretical limit of detection for pyocyanin was determined to be 559 nM. The electrophoretic mobilities of methylene blue (0.0236 ± 0.0007 mm2 /V·s), neutral red (0.0149 ± 0.0007 mm2 /V·s), and pyocyanin (0.0107 ± 0.0003 mm2 /V·s) were also determined.
Collapse
Affiliation(s)
- Martin K Kimani
- Department of Chemical Engineering, Northeastern University, Boston, MA, USA
| | - John Mwangi
- Department of Biology, Northeastern University, Boston, MA, USA
| | - Edgar D Goluch
- Department of Chemical Engineering, Northeastern University, Boston, MA, USA.,Department of Biology, Northeastern University, Boston, MA, USA.,Department of Bioengineering, Civil and Environmental Engineering, Northeastern University, Boston, MA, USA
| |
Collapse
|
16
|
Singhal HR, Prabhu A, Giri Nandagopal M, Dheivasigamani T, Mani NK. One-dollar microfluidic paper-based analytical devices: Do-It-Yourself approaches. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106126] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
17
|
Khaliliazar S, Öberg Månsson I, Piper A, Ouyang L, Réu P, Hamedi MM. Woven Electroanalytical Biosensor for Nucleic Acid Amplification Tests. Adv Healthc Mater 2021; 10:e2100034. [PMID: 33930257 DOI: 10.1002/adhm.202100034] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Revised: 03/14/2021] [Indexed: 01/07/2023]
Abstract
Fiber-based biosensors enable a new approach in analytical diagnostic devices. The majority of textile-based biosensors, however, rely on colorimetric detection. Here a woven biosensor that integrates microfluidics structures in combination with an electroanalytical readout based on a thiol-self-assembled monolayer (SAM) for Nucleic Acid Amplification Testing, NAATs is shown. Two types of fiber-based electrodes are systematically characterized: pure gold microwires (bond wire) and off-the-shelf plasma gold-coated polyester multifilament threads to evaluate their potential to form SAMs on their surface and their electrochemical performance in woven textile. A woven electrochemical DNA (E-DNA) sensor using a SAM-based stem-loop probe-modified gold microwire is fabricated. These sensors can specifically detect unpurified, isothermally amplified genomic DNA of Staphylococcus epidermidis (10 copies/µL) by recombinase polymerase amplification (RPA). This work demonstrates that textile-based biosensors have the potential for integrating and being employed as automated, sample-to-answer analytical devices for point-of-care (POC) diagnostics.
Collapse
Affiliation(s)
- Shirin Khaliliazar
- Department of Fibre and Polymer Technology School of Engineering Sciences in Chemistry, Biotechnology and Health KTH Royal Institute of Technology Tekninkringen 56‐58 Stockholm SE‐100 44 Sweden
| | - Ingrid Öberg Månsson
- Department of Fibre and Polymer Technology School of Engineering Sciences in Chemistry, Biotechnology and Health KTH Royal Institute of Technology Tekninkringen 56‐58 Stockholm SE‐100 44 Sweden
| | - Andrew Piper
- Department of Fibre and Polymer Technology School of Engineering Sciences in Chemistry, Biotechnology and Health KTH Royal Institute of Technology Tekninkringen 56‐58 Stockholm SE‐100 44 Sweden
| | - Liangqi Ouyang
- Department of Fibre and Polymer Technology School of Engineering Sciences in Chemistry, Biotechnology and Health KTH Royal Institute of Technology Tekninkringen 56‐58 Stockholm SE‐100 44 Sweden
| | - Pedro Réu
- Department of Fibre and Polymer Technology School of Engineering Sciences in Chemistry, Biotechnology and Health KTH Royal Institute of Technology Tekninkringen 56‐58 Stockholm SE‐100 44 Sweden
| | - Mahiar Max Hamedi
- Department of Fibre and Polymer Technology School of Engineering Sciences in Chemistry, Biotechnology and Health KTH Royal Institute of Technology Tekninkringen 56‐58 Stockholm SE‐100 44 Sweden
| |
Collapse
|
18
|
Prabhu A, Singhal H, Giri Nandagopal MS, Kulal R, Peralam Yegneswaran P, Mani NK. Knitting Thread Devices: Detecting Candida albicans Using Napkins and Tampons. ACS OMEGA 2021; 6:12667-12675. [PMID: 34056418 PMCID: PMC8154238 DOI: 10.1021/acsomega.1c00806] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Accepted: 04/22/2021] [Indexed: 05/14/2023]
Abstract
Reproducible and in situ microbial detection, particularly of microbes significant in urinary tract infections (UTIs) such as Candida albicans, provides a unique opportunity to bring equity in the healthcare outcomes of disenfranchised groups like women in low-resource settings. Here, we demonstrate a system to potentially detect vulvovaginal candidiasis by leveraging the properties of multifilament cotton threads in the form of microfluidic-thread-based analytical devices (μTADs) to develop a frugal microbial identification assay. A facile mercerization method using heptane wash to boost reagent absorption and penetration is also performed and is shown to be robust compared to other existing conventional mercerization methods. Furthermore, the twisted mercerized fibers are drop-cast with media consisting of l-proline β-naphthylamide, which undergoes hydrolysis by the enzyme l-proline aminopeptidase secreted by C. albicans, hence signaling the presence of the pathogen via simple color change with a limit of detection of 0.58 × 106 cfu/mL. The flexible and easily disposable thread-based detection device when integrated with menstrual hygiene products showed a detection time of 10 min using spiked vaginal discharge. The developed method boasts a long shelf life and high stability, making it a discreet detection device for testing, which provides new vistas for self-testing multiple diseases that are considered taboo in certain societies.
Collapse
Affiliation(s)
- Anusha Prabhu
- Department
of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| | - Hardik Singhal
- Department
of Chemical Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| | - M. S. Giri Nandagopal
- Department
of Mechanical Engineering, Indian Institute
of Technology, Kharagpur, Kharagpur 721302, India
| | - Reshma Kulal
- Department
of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| | - Prakash Peralam Yegneswaran
- Department
of Microbiology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
- Manipal
Centre for Infectious Diseases, Prasanna School of Public Health, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| | - Naresh Kumar Mani
- Department
of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
- Manipal
Centre for Infectious Diseases, Prasanna School of Public Health, Manipal Academy of Higher Education, Manipal, Karnataka 576104, India
| |
Collapse
|
19
|
Zhao Z, Li Q, Chen L, Zhao Y, Gong J, Li Z, Zhang J. A thread/fabric-based band as a flexible and wearable microfluidic device for sweat sensing and monitoring. LAB ON A CHIP 2021; 21:916-932. [PMID: 33438703 DOI: 10.1039/d0lc01075h] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Flexible biosensors for monitoring systems have emerged as a promising portable diagnostics platform due to their potential for in situ point-of-care (POC) analytic devices. Assessment of biological analytes in sweat can provide essential information for human physiology. Conventional measurements rely on laboratory equipment. This work exploits an alternative approach for epidermal sweat sensing and detection through a wearable microfluidic thread/fabric-based analytical device (μTFAD). This μTFAD is a flexible and skin-mounted band that integrates hydrophilic dot-patterns with a hydrophobic surface via embroidering thread into fabric. After chromogenic reaction treatment, the thread-embroidered patterns serve as the detection zones for sweat transferred by the hydrophilic threads, enabling precise analysis of local sweat loss, pH and concentrations of chloride and glucose in sweat. Colorimetric reference markers embroidered surrounding the working dots provide accurate data readout either by apparent color comparison or by digital acquirement through smartphone-assisted calibration plots. On-body tests were conducted on five healthy volunteers. Detection results of pH, chloride and glucose in sweat from the volunteers were 5.0-6.0, 25-80 mM and 50-200 μM by apparent color comparison with reference markers through direct visual observation. Similar results of 5.47-6.30, 50-77 mM and 47-66 μM for pH, chloride and glucose were obtained through calibration plots based on the RGB values from the smartphone app Lanse®. The limit of detection (LOD) is 10 mM for chloride concentration, 4.0-9.0 for pH and 10 μM for glucose concentration, respectively. For local sweat loss, it is found that the forehead is the region of heavy sweat loss. Sweat secretion is a cumulating process with a lower sweat rate at the beginning which increases as body movement continues along with increased heat production. These results demonstrate the capability and availability of our sensing device for quantitative detection of multiple biomarkers in sweat, suggesting the great potential for development of feasible non-invasive biosensors, with a similar performance to conventional measurements.
Collapse
Affiliation(s)
- Zhiqi Zhao
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China. and Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Qiujin Li
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China. and Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Linna Chen
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China. and Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Yu Zhao
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China. and Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Jixian Gong
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China. and Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Zheng Li
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China. and Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Jianfei Zhang
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China. and Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China and Collaborative Innovation Center for Eco-Textiles of Shandong Province, Shandong, Qingdao 266071, China
| |
Collapse
|
20
|
Costa-Rama E, Fernández-Abedul MT. Paper-Based Screen-Printed Electrodes: A New Generation of Low-Cost Electroanalytical Platforms. BIOSENSORS 2021; 11:51. [PMID: 33669316 PMCID: PMC7920281 DOI: 10.3390/bios11020051] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/20/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Screen-printed technology has helped considerably to the development of portable electrochemical sensors since it provides miniaturized but robust and user-friendly electrodes. Moreover, this technology allows to obtain very versatile transducers, not only regarding their design, but also their ease of modification. Therefore, in the last decades, the use of screen-printed electrodes (SPEs) has exponentially increased, with ceramic as the main substrate. However, with the growing interest in the use of cheap and widely available materials as the basis of analytical devices, paper or other low-cost flat materials have become common substrates for SPEs. Thus, in this revision, a comprehensive overview on paper-based SPEs used for analytical proposes is provided. A great variety of designs is reported, together with several examples to illustrate the main applications.
Collapse
|
21
|
Davis JJ, Foster SW, Grinias JP. Low-cost and open-source strategies for chemical separations. J Chromatogr A 2021; 1638:461820. [PMID: 33453654 PMCID: PMC7870555 DOI: 10.1016/j.chroma.2020.461820] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/12/2020] [Accepted: 12/14/2020] [Indexed: 12/18/2022]
Abstract
In recent years, a trend toward utilizing open access resources for laboratory research has begun. Open-source design strategies for scientific hardware rely upon the use of widely available parts, especially those that can be directly printed using additive manufacturing techniques and electronic components that can be connected to low-cost microcontrollers. Open-source software eliminates the need for expensive commercial licenses and provides the opportunity to design programs for specific needs. In this review, the impact of the "open-source movement" within the field of chemical separations is described, primarily through a comprehensive look at research in this area over the past five years. Topics that are covered include general laboratory equipment, sample preparation techniques, separations-based analysis, detection strategies, electronic system control, and software for data processing. Remaining hurdles and possible opportunities for further adoption of open-source approaches in the context of these separations-related topics are also discussed.
Collapse
Affiliation(s)
- Joshua J Davis
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States
| | - Samuel W Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States
| | - James P Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States.
| |
Collapse
|
22
|
Al Sulaiman D, Shapiro SJ, Gomez-Marquez J, Doyle PS. High-Resolution Patterning of Hydrogel Sensing Motifs within Fibrous Substrates for Sensitive and Multiplexed Detection of Biomarkers. ACS Sens 2021; 6:203-211. [PMID: 33351603 DOI: 10.1021/acssensors.0c02121] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
There has been an increasing and urgent demand to develop nucleic acid bioassays which not only offer high analytical performance but which are also amenable with point-of-care testing. Hydrogels present a versatile class of materials with biocompatible antifouling properties and the ability to be engineered for a range of advanced sensing applications. Fibrous substrates like nitrocellulose offer low-cost and durable platforms to run complex bioassays while enabling portability and ease of handling. We demonstrate herein the ability to synergistically combine these two materials into a portable biosensing platform by leveraging projection lithography. We demonstrate the direct polymerization of hydrogel sensing motifs within a range of fibrous substrates with precise control over their shape, size, location, and functionality. Spatial encoding of the hydrogel motifs enables the multiplex detection of multiple biomarkers on the same test. As a proof-of-concept, we apply the platform to the detection of microRNA, an emerging class of circulating biomarkers with promising potential for early diagnosis and monitoring of cancer. The assay offers a large dynamic range (over three orders of magnitude), high sensitivity (limit of detection of 2.5 amol), as well as versatility and ease of handling. Finally, the bioassay is validated using real biological samples, namely, total RNA extracted from the sera of late-stage breast cancer patients, demonstrating its utility and compatibility with clinical biosensing applications.
Collapse
Affiliation(s)
- Dana Al Sulaiman
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Sarah J. Shapiro
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Jose Gomez-Marquez
- Little Devices Lab, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Patrick S. Doyle
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
23
|
Sachdeva S, Davis RW, Saha AK. Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions. Front Bioeng Biotechnol 2021; 8:602659. [PMID: 33520958 PMCID: PMC7843572 DOI: 10.3389/fbioe.2020.602659] [Citation(s) in RCA: 90] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Accepted: 12/15/2020] [Indexed: 12/23/2022] Open
Abstract
Point-of-care testing (POCT) allows physicians to detect and diagnose diseases at or near the patient site, faster than conventional lab-based testing. The importance of POCT is considerably amplified in the trying times of the COVID-19 pandemic. Numerous point-of-care tests and diagnostic devices are available in the market including, but not limited to, glucose monitoring, pregnancy and infertility testing, infectious disease testing, cholesterol testing and cardiac markers. Integrating microfluidics in POCT allows fluid manipulation and detection in a singular device with minimal sample requirements. This review presents an overview of two technologies - (a.) Lateral Flow Assay (LFA) and (b.) Nucleic Acid Amplification - upon which a large chunk of microfluidic POCT diagnostics is based, some of their applications, and commercially available products. Apart from this, we also delve into other microfluidic-based diagnostics that currently dominate the in-vitro diagnostic (IVD) market, current testing landscape for COVID-19 and prospects of microfluidics in next generation diagnostics.
Collapse
Affiliation(s)
| | | | - Amit K. Saha
- Genome Technology Center, School of Medicine, Stanford University, Palo Alto, CA, United States
| |
Collapse
|
24
|
Dabbagh SR, Rabbi F, Doğan Z, Yetisen AK, Tasoglu S. Machine learning-enabled multiplexed microfluidic sensors. BIOMICROFLUIDICS 2020; 14:061506. [PMID: 33343782 PMCID: PMC7733540 DOI: 10.1063/5.0025462] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2020] [Accepted: 12/01/2020] [Indexed: 05/02/2023]
Abstract
High-throughput, cost-effective, and portable devices can enhance the performance of point-of-care tests. Such devices are able to acquire images from samples at a high rate in combination with microfluidic chips in point-of-care applications. However, interpreting and analyzing the large amount of acquired data is not only a labor-intensive and time-consuming process, but also prone to the bias of the user and low accuracy. Integrating machine learning (ML) with the image acquisition capability of smartphones as well as increasing computing power could address the need for high-throughput, accurate, and automatized detection, data processing, and quantification of results. Here, ML-supported diagnostic technologies are presented. These technologies include quantification of colorimetric tests, classification of biological samples (cells and sperms), soft sensors, assay type detection, and recognition of the fluid properties. Challenges regarding the implementation of ML methods, including the required number of data points, image acquisition prerequisites, and execution of data-limited experiments are also discussed.
Collapse
Affiliation(s)
| | - Fazle Rabbi
- Department of Mechanical Engineering, Koç University, Sariyer, Istanbul 34450, Turkey
| | | | - Ali Kemal Yetisen
- Department of Chemical Engineering, Imperial College London, London SW7 2AZ, United Kingdom
| | | |
Collapse
|
25
|
Khan JU, Sayyar S, Paull B, Innis PC. Novel Approach toward Electrofluidic Substrates Utilizing Textile-Based Braided Structure. ACS APPLIED MATERIALS & INTERFACES 2020; 12:45618-45628. [PMID: 32910632 DOI: 10.1021/acsami.0c13740] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Electrofluidics is the unique combination of electrophoresis and microfluidics, which has opened up broad opportunities for bioanalysis and multiplexed assay. These systems typically comprise inaccessible and fully enclosed microcapillary or microchannels, with limited sample loading capacities and no direct access to the solutes within. Here, we investigate the application of multiyarn textile assemblies which provides an open and surface accessible electrophoretic separation platform. Three-dimensional (3D) textile structures have been produced using conventional knitting and braiding techniques from a range of commercially available yarns. Capillary zone electrophoresis separation studies have been carried out on these substrates using fluorescent anionic (fluorescence, FL) and cationic (rhodamine-B, Rh-B) markers. The effects of different yarn surface chemistry, textile fabrication technique, and electrolyte ionic strength on the electrophoretic mobility of the test analytes have been studied. From the broad range of yarns investigated, polyester was shown to have the highest electrophoretic mobility for Rh-B (6 × 10-4 cm2 V-1 s-1) and for FL (4 × 10-4 cm2 V-1 s-1). The braiding approach, being simple and versatile, was found to be the most effective route to produce 3D textile-based structures and offered the potential for selective movement and targeted delivery to different channels. Composite braids made with yarns of differential surface chemistries further revealed a unique behavior of separation and parallel movement of oppositely charged ionic species. We also demonstrate the feasibility to apply isotachophoresis (ITP) on these braided textile substrates to rapidly focus dispersed FL sample bands. Here, we demonstrate the focusing of FL from a dispersed band into narrow band with a 400 times reduction in sample width over 90 s. Owing to the simplicity and reproducibility of the developed approach, textile-based inverted microfluidic applications are expected to enable opportunities in bioanalysis, proteomics, and rapid clinical diagnostics.
Collapse
Affiliation(s)
- Jawairia Umar Khan
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
- Department of Fibre and Textile Technology, University of Agriculture, Faisalabad 38000, Pakistan
| | - Sepidar Sayyar
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility-Materials Node, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7005, Australia
| | - Peter C Innis
- ARC Centre of Excellence for Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility-Materials Node, Innovation Campus, University of Wollongong, Wollongong, New South Wales 2500, Australia
| |
Collapse
|
26
|
Öberg Månsson I, Piper A, Hamedi MM. Weaving Off-The-Shelf Yarns into Textile Micro Total Analysis Systems (μTAS). Macromol Biosci 2020; 20:e2000150. [PMID: 32686256 DOI: 10.1002/mabi.202000150] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/30/2020] [Indexed: 12/28/2022]
Abstract
Textile based biosensors have garnered much interest in recent years. Devices woven out of yarns have the ability to be incorporated into clothing and bandages. Most woven devices reported in the literature require yarns that are not available on an industrial scale or that require modifications which are not possible in large scale manufacturing. In this work, commercially produced yarns are taken without any modification or cleaning, and developed woven textile diagnostic devices out of them. The yarn properties that are important to their function within the device have been characterised and discussed. The wicking ability and analyte retention of Coolmax yarns, developed to wick sweat in mass produced sportswear, are determined. The electrochemistry and functionalizability of Au coated multifilament yarns are investigated with no cleaning or treatment and are found to have as good a thiolate self-assembled monolayer (SAM) coverage as cleaned Au disk electrodes. The feasibility of using these yarns is established off the shelf, with no cleaning, to make woven capillary force driven microfluidic devices and three electrode sensing devices. A proof of principle three electrode system capable of detecting clinically relevant concentrations of glucose in human sweat is reported.
Collapse
Affiliation(s)
- Ingrid Öberg Månsson
- Department of Fibre and Polymer technology, KTH Royal Institute of Technology, Teknikringen 56, Stockholm, 10044, Sweden
| | - Andrew Piper
- Department of Fibre and Polymer technology, KTH Royal Institute of Technology, Teknikringen 56, Stockholm, 10044, Sweden
| | - Mahiar Max Hamedi
- Department of Fibre and Polymer technology, KTH Royal Institute of Technology, Teknikringen 56, Stockholm, 10044, Sweden
| |
Collapse
|
27
|
Abstract
The microfluidics field is at a critical crossroads. The vast majority of microfluidic devices are presently manufactured using micromolding processes that work very well for a reduced set of biocompatible materials, but the time, cost, and design constraints of micromolding hinder the commercialization of many devices. As a result, the dissemination of microfluidic technology-and its impact on society-is in jeopardy. Digital manufacturing (DM) refers to a family of computer-centered processes that integrate digital three-dimensional (3D) designs, automated (additive or subtractive) fabrication, and device testing in order to increase fabrication efficiency. Importantly, DM enables the inexpensive realization of 3D designs that are impossible or very difficult to mold. The adoption of DM by microfluidic engineers has been slow, likely due to concerns over the resolution of the printers and the biocompatibility of the resins. In this article, we review and discuss the various printer types, resolution, biocompatibility issues, DM microfluidic designs, and the bright future ahead for this promising, fertile field.
Collapse
Affiliation(s)
- Arman Naderi
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA;
| | - Nirveek Bhattacharjee
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA;
| | - Albert Folch
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA;
| |
Collapse
|
28
|
Adamo CB, Junger AS, Bressan LP, da Silva JAF, Poppi RJ, de Jesus DP. Fast and straightforward in-situ synthesis of gold nanoparticles on a thread-based microfluidic device for application in surface-enhanced Raman scattering detection. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104985] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
29
|
Li Y, Fischer R, Zboray R, Boillat P, Camenzind M, Toncelli C, Rossi RM. Laser-Engraved Textiles for Engineering Capillary Flow and Application in Microfluidics. ACS APPLIED MATERIALS & INTERFACES 2020; 12:29908-29916. [PMID: 32506905 DOI: 10.1021/acsami.0c03988] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Steering capillary flow in textiles is of great significance in developing affordable and portable microfluidics devices. However, owing to the complex fibrous network, it remains a great challenge to achieve capillary flows with precise filling fronts. Here, an in situ laser engraving route is reported to accurately and rapidly etch textiles for manipulating capillary flow. The heterogeneity of the textile structure is enhanced because of the directional spreading of molten fibers polymer under the control of surface energy minimization. The principle of achieved anisotropic wicking of a water droplet in laser-engraved textiles is proposed. This understanding enables patterning the filling front of a fluid in different shapes, including arrow, straight line, diamond, and annulus. Precise capillary flow in textile-based microfluidics can benefit application in many fields, such as chemical analysis, biological detection, materials synthesis, multiliquid delivery. The laser engraving strategy has the advantages of simplicity, full scalability, and time rapidity, which provides an efficient avenue to steer capillary flow in diverse textiles for manufacturing customized microfluidic devices.
Collapse
Affiliation(s)
- Yifan Li
- Laboratory for Biomimetic Membranes & Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, St. Gallen 9014, Switzerland
| | - Robert Fischer
- Laboratory for Biomimetic Membranes & Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, St. Gallen 9014, Switzerland
- Chair of Building Physics, ETH Zürich, Swiss Federal Institute of Technology, Zurich 8092, Switzerland
- Laboratory for Multiscale Studies in Building Physics, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
| | - Robert Zboray
- Centers for X-ray Analytics, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
| | - Pierre Boillat
- Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institute, Villigen PSI 5232, Switzerland
| | - Martin Camenzind
- Laboratory for Biomimetic Membranes & Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, St. Gallen 9014, Switzerland
| | - Claudio Toncelli
- Laboratory for Biomimetic Membranes & Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, St. Gallen 9014, Switzerland
| | - Rene M Rossi
- Laboratory for Biomimetic Membranes & Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, St. Gallen 9014, Switzerland
| |
Collapse
|
30
|
Jarujamrus P, Prakobkij A, Puchum S, Chaisamdaeng S, Meelapsom R, Anutrasakda W, Amatatongchai M, Chairam S, Citterio D. Acid-base titration using a microfluidic thread-based analytical device (μTAD). Analyst 2020; 145:4457-4466. [PMID: 32378683 DOI: 10.1039/d0an00522c] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
This work presents the development and application of a novel analytical approach for the determination of acid and base concentrations by titration using a microfluidic thread-based analytical device (μTAD). This approach proved to be a simple to fabricate and to use, high precision, and cost-efficient means of acid-base quantification. The μTAD was fabricated by immobilizing the untreated cotton threads onto a wood frame, followed by pre-coating with an indicator (20 μL) and a primary standard solution (3 μL), and was tested using real samples including drug, food, and household products where 3 μL of each sample was dropped onto the center of a thread. Afterward, the distance of color change on the thread, easily observed and measured using the naked eye and a ruler, was used for analysis. The analysis using the μTAD, completed within 2 minutes and validated by the conventional titration, showed high accuracy and precision (RSD < 12.9%), good linearity ranges and low limit of quantification. The fabricated μTAD also remained stable for an extended period of time (>2 weeks under various storage conditions).
Collapse
Affiliation(s)
- Purim Jarujamrus
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
| | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Cabot JM, Daikuara LY, Yue Z, Hayes P, Liu X, Wallace GG, Paull B. Electrofluidic control of bioactive molecule delivery into soft tissue models based on gelatin methacryloyl hydrogels using threads and surgical sutures. Sci Rep 2020; 10:7120. [PMID: 32345999 PMCID: PMC7188853 DOI: 10.1038/s41598-020-63785-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 04/06/2020] [Indexed: 12/22/2022] Open
Abstract
The delivery of bioactive molecules (drugs) with control over spatial distribution remains a challenge. Herein, we demonstrate for the first time an electrofluidic approach to controlled delivery into soft tissue models based on gelatin methacryloyl (GelMA) hydrogels. This was achieved using a surgical suture, whereby transport of bioactive molecules, including drugs and proteins, was controlled by imposition of an electric field. Commonly employed surgical sutures or acrylic threads were integrated through the hydrogels to facilitate the directed introduction of bioactive species. The platform consisted of two reservoirs into which the ends of the thread were immersed. The anode and cathode were placed separately into each reservoir. The thread was taken from one reservoir to the other through the gel. When current was applied, biomolecules loaded onto the thread were directed into the gel. Under the same conditions, the rate of movement of the biomolecules along GelMA was dependent on the magnitude of the current. Using 5% GelMA and a current of 100 µA, 2 uL of fluorescein travelled through the hydrogel at a constant velocity of 7.17 ± 0.50 um/s and took less than 8 minutes to exit on the thread. Small molecules such as riboflavin migrated faster (5.99 ± 0.40 μm/s) than larger molecules such as dextran (2.26 ± 0.55 μm/s with 4 kDa) or BSA (0.33 ± 0.07 μm/s with 66.5 kDa). A number of commercial surgical sutures were tested and found to accommodate the controlled movement of biomolecules. Polyester, polyglactin 910, glycolide/lactide copolymer and polyglycolic acid braided sutures created adequate fluid connection between the electrodes and the hydrogel. With a view to application in skin inflammatory diseases and wound treatment, wound healing, slow and controlled delivery of dexamethasone 21-phosphate disodium salt (DSP), an anti-inflammatory prodrug, was achieved using medical surgicryl PGA absorbable suture. After 2 hours of electrical stimulation, still 81.1% of the drug loaded was encapsulated within the hydrogel.
Collapse
Affiliation(s)
- Joan M Cabot
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, Faculty of Chemistry, University of Tasmania, Tasmania, TAS 7005, Australia
| | - Luciana Y Daikuara
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute (IPRI), University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Zhilian Yue
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute (IPRI), University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Patricia Hayes
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute (IPRI), University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Xiao Liu
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute (IPRI), University of Wollongong, Wollongong, NSW, 2522, Australia
| | - Gordon G Wallace
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute (IPRI), University of Wollongong, Wollongong, NSW, 2522, Australia.
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, Faculty of Chemistry, University of Tasmania, Tasmania, TAS 7005, Australia.
| |
Collapse
|
32
|
Li S, Ma Z, Cao Z, Pan L, Shi Y. Advanced Wearable Microfluidic Sensors for Healthcare Monitoring. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1903822. [PMID: 31617311 DOI: 10.1002/smll.201903822] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 09/12/2019] [Indexed: 05/24/2023]
Abstract
Wearable flexible sensors based on integrated microfluidic networks with multiplex analysis capability are emerging as a new paradigm to assess human health status and show great potential in application fields such as clinical medicine and athletic monitoring. Well-designed microfluidic sensors can be attached to the skin surface to acquire various pieces of physiological information with high precision, such as sweat loss, information regarding metabolites, and electrolyte balance. Herein, the recent progress of wearable microfluidic sensors for applications in healthcare monitoring is summarized, including analysis principles and microfabrication methods. Finally, the challenges and opportunities for wearable microfluidic sensors in practical applications are discussed.
Collapse
Affiliation(s)
- Sheng Li
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| | - Zhong Ma
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| | - Zhonglin Cao
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| | - Lijia Pan
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| | - Yi Shi
- Collaborative Innovation Center of Advanced Microstructures, Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, School of Electronic Science and Engineering, Nanjing University, 210093, Nanjing, China
| |
Collapse
|
33
|
Song J, Ouyang Z, Lu W, Cai L. Instrument-free detection of polyphenols with a thread-based analytical device. ROYAL SOCIETY OPEN SCIENCE 2020; 7:192130. [PMID: 32269816 PMCID: PMC7137958 DOI: 10.1098/rsos.192130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 02/11/2020] [Indexed: 06/11/2023]
Abstract
We described an instrument-free method for quantitative analysis of the total content of tea polyphenols by measurement of the length of a coloured band. Polyphenols react with ferrous ions to form a colourless ferrous-polyphenols complex on cotton threads, which could be adsorbed on the threads. The complex was then oxidized to form a blue-black ferric-polyphenols complex, generating a blue-black band on the cotton thread. The length of this blue-black band was then measured to detect the total content of polyphenols. The advantages of this method include low cost, rapid analysis, low consumption, easy fabrication and operation. Furthermore, the digital instrument (scanner or camera) as well as the image processing software are not required. This proposed method was used to detect polyphenols in tea leaf extracts with an analytical result agreeing well with that obtained by a standard method, which demonstrates its potential in monitoring of tea leaf quality, especially in resource-limited regions and settings.
Collapse
Affiliation(s)
| | | | | | - Longfei Cai
- Author for correspondence: Longfei Cai e-mail:
| |
Collapse
|
34
|
Chen L, Cabot JM, Sanz Rodriguez E, Ghiasvand A, Innis PC, Paull B. Thread-based isoelectric focusing coupled with desorption electrospray ionization mass spectrometry. Analyst 2020; 145:6928-6936. [DOI: 10.1039/d0an01344g] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Efficient ‘on-thread’ isoelectric focusing of proteins, with direct on-thread detection using desorption electrospray ionisation mass spectrometry.
Collapse
Affiliation(s)
- Liang Chen
- ARC Centre of Excellence for Electromaterials Science (ACES)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Joan M. Cabot
- ARC Centre of Excellence for Electromaterials Science (ACES)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Estrella Sanz Rodriguez
- Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Alireza Ghiasvand
- Australian Centre for Research on Separation Science (ACROSS)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| | - Peter C. Innis
- ARC Centre of Excellence for Electromaterials Science (ACES)
- AIIM Facility
- Innovation campus
- University of Wollongong
- Australia
| | - Brett Paull
- ARC Centre of Excellence for Electromaterials Science (ACES)
- School of Natural Sciences
- University of Tasmania
- Sandy Bay
- Hobart
| |
Collapse
|
35
|
Prabhu A, Nandagopal M. S. G, Peralam Yegneswaran P, Prabhu V, Verma U, Mani NK. Thread integrated smart-phone imaging facilitates early turning point colorimetric assay for microbes. RSC Adv 2020; 10:26853-26861. [PMID: 35515782 PMCID: PMC9055509 DOI: 10.1039/d0ra05190j] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Accepted: 07/13/2020] [Indexed: 12/19/2022] Open
Abstract
A proof-of-concept unifying thread devices and smart-phone imaging for low-cost microbial detection based on simple colour change.
Collapse
Affiliation(s)
- Anusha Prabhu
- Department of Biotechnology
- Manipal Institute of Technology
- Manipal Academy of Higher Education
- Manipal 576104
- India
| | - Giri Nandagopal M. S.
- Department of Mechanical Engineering
- Indian Institute of Technology
- Kharagpur 721302
- India
| | - Prakash Peralam Yegneswaran
- Department of Microbiology
- Kasturba Medical College Manipal
- Manipal Academy of Higher Education
- Manipal 576104
- India
| | - Vijendra Prabhu
- Department of Biotechnology
- Manipal Institute of Technology
- Manipal Academy of Higher Education
- Manipal 576104
- India
| | - Ujjwal Verma
- Department of Electronics & Communication
- Manipal Institute of Technology
- Manipal Academy of Higher Education
- Manipal 576104
- India
| | - Naresh Kumar Mani
- Department of Biotechnology
- Manipal Institute of Technology
- Manipal Academy of Higher Education
- Manipal 576104
- India
| |
Collapse
|
36
|
Huang Y, Xu T, Wang W, Wen Y, Li K, Qian L, Zhang X, Liu G. Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments. Mikrochim Acta 2019; 187:70. [PMID: 31853644 DOI: 10.1007/s00604-019-3822-x] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Accepted: 09/12/2019] [Indexed: 12/25/2022]
Abstract
This review (with 187 refs.) summarizes the progress that has been made in the design of lateral flow biosensors (LFBs) based on the use of micro- and nano-materials. Following a short introduction into the field, a first section covers features related to the design of LFBs, with subsections on strip-based, cotton thread-based and vertical flow- and syringe-based LFBs. The next chapter summarizes methods for sample pretreatment, from simple method to membrane-based methods, pretreatment by magnetic methods to device-integrated sample preparation. Advances in flow control are treated next, with subsections on cross-flow strategies, delayed and controlled release and various other strategies. Detection conditionst and mathematical modelling are briefly introduced in the following chapter. A further chapter covers methods for reliability improvement, for example by adding other validation lines or adopting different detection methods. Signal readouts are summarized next, with subsections on color-based, luminescent, smartphone-based and SERS-based methods. A concluding section summarizes the current status and addresses challenges in future perspectives. Graphical abstractRecent development and breakthrough points of lateral flow biosensors.
Collapse
Affiliation(s)
- Yan Huang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China.,Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China.,Department of Chemistry and biochemistry, North Dakota State University, Fargo, ND, 58105, USA
| | - Tailin Xu
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Wenqian Wang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Yongqiang Wen
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China
| | - Kun Li
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China
| | - Lisheng Qian
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China.
| | - Xueji Zhang
- Research Center for Bioengineering and Sensing Technology, University of Science & Technology Beijing, Beijing, 100083, People's Republic of China. .,Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China. .,School of Biomedical Engineering, Shenzhen University Healthy Science Center, Shenzhen, Guangdong, 518060, People's Republic of China.
| | - Guodong Liu
- Institute of Biomedical and Health, School of Life and Health Science, Anhui Science and Technology University, Fengyang, Anhui, 233100, People's Republic of China. .,Department of Chemistry and biochemistry, North Dakota State University, Fargo, ND, 58105, USA.
| |
Collapse
|
37
|
Farajikhah S, Innis PC, Paull B, Wallace GG, Harris AR. Facile Development of a Fiber-Based Electrode for Highly Selective and Sensitive Detection of Dopamine. ACS Sens 2019; 4:2599-2604. [PMID: 31564101 DOI: 10.1021/acssensors.9b01583] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A facile one-step method was used to create a selective and sensitive electrode for dopamine (DA) detection based upon a stainless steel (SS) filament substrate and reduced graphene oxide (rGO). The electrode successfully and selectively detects DA in the presence of uric acid and ascorbic acid without the need for a Nafion coating. The proposed electrode is easy to fabricate, low-cost, flexible, and strong. The rGO-SS electrode could also be incorporated into a three-dimensional braided structure enabling DA detection in a two-electrode fiber system. The sensor is an excellent candidate for production of an affordable, robust, and flexible wearable and portable sensor and expands the application of textiles in point of care diagnostic devices.
Collapse
Affiliation(s)
- Syamak Farajikhah
- Institute of Photonics and Optical Sciences (IPOS), School of Physics, The University of Sydney, Sydney, New South Wales, 2006, Australia
| | | | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania, 7005, Australia
| | | | | |
Collapse
|
38
|
Elomaa J, Gallegos L, Gomez FA. Cord-Based Microfluidic Chips as A Platform for ELISA and Glucose Assays. MICROMACHINES 2019; 10:mi10090614. [PMID: 31540182 PMCID: PMC6780352 DOI: 10.3390/mi10090614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Revised: 09/03/2019] [Accepted: 09/13/2019] [Indexed: 05/13/2023]
Abstract
This paper describes the development and application of microfluidic cord-based analytical devices (µCADs) in two enzyme-linked immunosorbent assays (ELISAs) and glucose assay. In this study, biotinylated goat anti-mouse immunoglobulin (IgG) antibody, rabbit IgG antibody, and glucose are quantitatively detected. In the ELISA systems, the antibody is spotted on the cord at the detection site and a series of washes, followed by streptavidin-alkaline phosphatase (Strep-ALP) or alkaline phosphatase (ALP)-conjugated secondary antibody and colorimetric substrate, completing the experiment. The devices are subsequently scanned and analyzed yielding a correlation between inverse yellow or inverse blue intensity and antibody concentration. For the first ELISA, a linear range of detection was observed at lower concentrations (2.50 × 10-4-1.75 × 10-3 mg/mL) of Strep-ALP with saturation of the enzyme achieved at higher concentrations (>2.50 × 10-4). For the second ELISA, the L50 was demonstrated to be 167.6 fmol/zone. The glucose assay consisted of spotting increasing concentrations of glucose on the analysis sites and transporting, via capillary action, a solution containing glucose oxidase (GOx), horseradish peroxidase (HRP), and potassium iodide (KI) to the detection sites realizing a yellow-brown color indicating oxidation of iodide to iodine. The device was then dried, scanned, and analyzed to show the correlation between yellow inverse intensity and glucose. Glucose in artificial urine showed good correlation using the devices.
Collapse
Affiliation(s)
- Jenny Elomaa
- Department of Chemistry and Biochemistry, California State University, Los Angeles, 5151 State University Drive, Los Angeles, CA 90032-8202, USA.
| | - Laura Gallegos
- Department of Chemistry and Biochemistry, California State University, Los Angeles, 5151 State University Drive, Los Angeles, CA 90032-8202, USA.
| | - Frank A Gomez
- Department of Chemistry and Biochemistry, California State University, Los Angeles, 5151 State University Drive, Los Angeles, CA 90032-8202, USA.
| |
Collapse
|
39
|
Sarma B, Shahapure V, Dalal A, Basu DN. Experimental characterization of the growth dynamics during capillarity-driven droplet generation. Phys Rev E 2019; 100:013106. [PMID: 31499850 DOI: 10.1103/physreve.100.013106] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Indexed: 11/07/2022]
Abstract
The transient dynamics of a growing droplet in a yarn is explored following the spatiotemporal evolution of the three-phase contact line as well as the liquid-air interface with the help of videographic techniques and subsequent image analyses. The spontaneous capillary flow of liquids in a porous network is used to generate a droplet on the freely hanging end of a yarn whose other end is dipped continuously in a liquid reservoir. The growing droplet initially moves upward due to surface tension until the attainment of a critical volume, beyond which gravity is able to pull it downward until detachment. Based upon the spatiotemporal trajectory of the three-phase contact line of the droplet, the entirety of the associated growth dynamics can be divided in three distinct regimes, namely, "radial growth," "axial growth," and "motion" stages. The transition from one to the other is governed by the subtle interplay between the capillary and the gravity forces. Several experimental fluids are considered to elucidate the effect of the fluid properties on the transient contact line and interfacial dynamics of drops. The kinetics of the three-phase contact line and the radius of the droplet is found to follow two distinct exponential scaling laws, developed through the combination of the relevant forces. A mathematical model has also been proposed to predict the critical volume of the growing droplet in relation to its final volume, beyond which gravity controls the transient dynamics.
Collapse
Affiliation(s)
- Bhaskarjyoti Sarma
- Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati-781039, India
| | - Vijay Shahapure
- Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati-781039, India
| | - Amaresh Dalal
- Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati-781039, India
| | - Dipankar N Basu
- Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati-781039, India
| |
Collapse
|
40
|
Rumaner M, Horowitz L, Ovadya A, Folch A. Thread as a Low-Cost Material for Microfluidic Assays on Intact Tumor Slices. MICROMACHINES 2019; 10:mi10070481. [PMID: 31319620 PMCID: PMC6680473 DOI: 10.3390/mi10070481] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2019] [Revised: 07/13/2019] [Accepted: 07/13/2019] [Indexed: 01/01/2023]
Abstract
In this paper we describe the use of thread as a low-cost material for a microfluidic chemosensitivity assay that uses intact tumor tissue ex vivo. Today, the need for new and effective cancer treatments is greater than ever, but unfortunately, the cost of developing new chemotherapy drugs has never been higher. Implementation of low-cost microfluidic techniques into drug screening devices could potentially mitigate some of the immense cost of drug development. Thread is an ideal material for use in drug screening as it is inexpensive, widely available, and can transport liquid without external pumping hardware, i.e., via capillary action. We have developed an inexpensive microfluidic delivery prototype that uses silk threads to selectively deliver fluids onto subregions of living xenograft tumor slices. Our device can be fabricated completely for less than $0.25 in materials and requires no external equipment to operate. We found that by varying thread materials, we could optimize device characteristics, such as flow rate; we specifically explored the behavior of silk, nylon, cotton, and polyester. The incremental cost of our device is insignificant compared to the tissue culture supplies. The use of thread as a microfluidic material has the potential to produce inexpensive, accessible, and user-friendly devices for drug testing that are especially suited for low-resource settings.
Collapse
Affiliation(s)
- Maxwell Rumaner
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Seattle, WA 98105, USA.
| | - Lisa Horowitz
- Department of Pathology, University of Washington, 1959 NE Pacific St, Seattle, WA 98195, USA
| | - Avital Ovadya
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Seattle, WA 98105, USA
| | - Albert Folch
- Department of Pathology, University of Washington, 1959 NE Pacific St, Seattle, WA 98195, USA
| |
Collapse
|
41
|
Abstract
Open microfluidic capillary systems are a rapidly evolving branch of microfluidics where fluids are manipulated by capillary forces in channels lacking physical walls on all sides. Typical channel geometries include grooves, rails, or beams and complex systems with multiple air-liquid interfaces. Removing channel walls allows access for retrieval (fluid sampling) and addition (pipetting reagents or adding objects like tissue scaffolds) at any point in the channel; the entire channel becomes a "device-to-world" interface, whereas such interfaces are limited to device inlets and outlets in traditional closed-channel microfluidics. Open microfluidic capillary systems are simple to fabricate and reliable to operate. Prototyping methods (e.g., 3D printing) and manufacturing methods (e.g., injection molding) can be used seamlessly, accelerating development. This Perspective highlights fundamentals of open microfluidic capillary systems including unique advantages, design considerations, fabrication methods, and analytical considerations for flow; device features that can be combined to create a "toolbox" for fluid manipulation; and applications in biology, diagnostics, chemistry, sensing, and biphasic applications.
Collapse
Affiliation(s)
- Erwin Berthier
- University of Washington, Department of Chemistry, Seattle, Washington 98195, USA
| | - Ashley M. Dostie
- University of Washington, Department of Chemistry, Seattle, Washington 98195, USA
| | - Ulri N. Lee
- University of Washington, Department of Chemistry, Seattle, Washington 98195, USA
| | - Jean Berthier
- University of Washington, Department of Chemistry, Seattle, Washington 98195, USA
| | - Ashleigh B. Theberge
- University of Washington, Department of Chemistry, Seattle, Washington 98195, USA
- University of Washington School of Medicine, Department of Urology, Seattle, Washington 98105, USA
| |
Collapse
|
42
|
Naeimirad M, Abuzade R, Babaahmadi V, Dabirian F. Microfluidic through fibrous structures: Recent developments and future trends. ACTA ACUST UNITED AC 2019. [DOI: 10.1002/mdp2.78] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Affiliation(s)
- Mohammadreza Naeimirad
- Department of Materials and Textile Engineering, Faculty of EngineeringRazi University Kermanshah Iran
| | - RamazanAli Abuzade
- Department of Materials and Textile Engineering, Faculty of EngineeringRazi University Kermanshah Iran
| | - Vahid Babaahmadi
- Department of Materials and Textile Engineering, Faculty of EngineeringRazi University Kermanshah Iran
| | - Farzad Dabirian
- Department of Materials and Textile Engineering, Faculty of EngineeringRazi University Kermanshah Iran
| |
Collapse
|
43
|
Weng X, Kang Y, Guo Q, Peng B, Jiang H. Recent advances in thread-based microfluidics for diagnostic applications. Biosens Bioelectron 2019; 132:171-185. [PMID: 30875629 PMCID: PMC7127036 DOI: 10.1016/j.bios.2019.03.009] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 03/02/2019] [Accepted: 03/07/2019] [Indexed: 02/06/2023]
Abstract
Over the past decades, researchers have been seeking attractive substrate materials to keep microfluidics improving to outbalance the drawbacks and issues. Cellulose substrates, including thread, paper and hydrogels are alternatives due to their distinct structural and mechanical properties for a number of applications. Thread have gained considerable attention and become promising powerful tool due to its advantages over paper-based systems thus finds numerous applications in the development of diagnostic systems, smart bandages and tissue engineering. To the best of our knowledge, no comprehensive review articles on the topic of thread-based microfluidics have been published and it is of significance for many scientific communities working on Microfluidics, Biosensors and Lab-on-Chip. This review gives an overview of the advances of thread-based microfluidic diagnostic devices in a variety of applications. It begins with an overall introduction of the fabrication followed by an in-depth review on the detection techniques in such devices and various applications with respect to effort and performance to date. A few perspective directions of thread-based microfluidics in its development are also discussed. Thread-based microfluidics are still at an early development stage and further improvements in terms of fabrication, analytical strategies, and function to become low-cost, low-volume and easy-to-use point-of-care (POC) diagnostic devices that can be adapted or commercialized for real world applications.
Collapse
Affiliation(s)
- Xuan Weng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China
| | - Yuejun Kang
- Institute for Clean Energy and Advanced Materials, Faculty of Materials and Energy, Southwest University, Chongqing 400715, China
| | - Qian Guo
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China
| | - Bei Peng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China
| | - Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, China.
| |
Collapse
|
44
|
Farajikhah S, Cabot JM, Innis PC, Paull B, Wallace G. Life-Saving Threads: Advances in Textile-Based Analytical Devices. ACS COMBINATORIAL SCIENCE 2019; 21:229-240. [PMID: 30640423 DOI: 10.1021/acscombsci.8b00126] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Novel approaches that incorporate electrofluidic and microfluidic technologies are reviewed to illustrate the translation of traditional enclosed structures into open and accessible textile based platforms. Through the utilization of on-fiber and on-textile microfluidics, it is possible to invert the typical enclosed capillary column or microfluidic "chip" platform, to achieve surface accessible efficient separations and fluid handling, while maintaining a microfluidic environment. The open fiber/textile based fluidics approach immediately provides new possibilities to interrogate, manipulate, redirect, extract, characterize, and quantify solutes and target species at any point in time during such processes as on-fiber electrodriven separations. This approach is revolutionary in its simplicity and provides many potential advantages not otherwise afforded by the more traditional enclosed platforms.
Collapse
Affiliation(s)
- Syamak Farajikhah
- ARC Centre of Excellence in Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, New South Wales 2500, Australia
| | - Joan M. Cabot
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, Faculty of Chemistry, University of Tasmania, Tasmania 7005, Australia
| | - Peter C. Innis
- ARC Centre of Excellence in Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility − Materials Node, Innovation Campus, University of Wollongong, New South Wales 2522, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS) and ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, Faculty of Chemistry, University of Tasmania, Tasmania 7005, Australia
| | - Gordon Wallace
- ARC Centre of Excellence in Electromaterials Science (ACES), AIIM Facility, Innovation Campus, University of Wollongong, New South Wales 2500, Australia
- Australian National Fabrication Facility − Materials Node, Innovation Campus, University of Wollongong, New South Wales 2522, Australia
| |
Collapse
|
45
|
Oliveira NM, Vilabril S, Oliveira MB, Reis RL, Mano JF. Recent advances on open fluidic systems for biomedical applications: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 97:851-863. [DOI: 10.1016/j.msec.2018.12.040] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 10/26/2018] [Accepted: 12/11/2018] [Indexed: 01/04/2023]
|
46
|
Promphet N, Rattanawaleedirojn P, Siralertmukul K, Soatthiyanon N, Potiyaraj P, Thanawattano C, Hinestroza JP, Rodthongkum N. Non-invasive textile based colorimetric sensor for the simultaneous detection of sweat pH and lactate. Talanta 2019; 192:424-430. [PMID: 30348413 DOI: 10.1016/j.snb.2020.128549] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Revised: 09/21/2018] [Accepted: 09/23/2018] [Indexed: 05/18/2023]
Abstract
A non-invasive textile-based colorimetric sensor for the simultaneous detection of sweat pH and lactate was created by depositing of three different layers onto a cotton fabric: 1.) chitosan, 2.) sodium carboxymethyl cellulose, and 3.) indicator dye or lactate assay. This sensor was characterized using field emission scanning electron microscopy and fourier transform infrared spectroscopy. Then, this sensor was used to measure pH and lactate concentration using the same sweat sample. The sensing element for sweat pH was composed of a mixture of methyl orange and bromocresol green while a lactate enzymatic assay was chosen for the lactate sensor. The pH indicator gradually shifted from red to blue as the pH increased, whereas the purple color intensity increased with the concentration of lactate in the sweat. By comparing these colors with a standard calibration, this platform can be used to estimate the sweat pH (1-14) and the lactate level (0-25 mM). Fading of the colors of this sensor was prevented by using cetyltrimethylammonium bromide (CTAB). The flexibility of this textile based sensor allows it to be incorporated into sport apparels and accessories hence potentially enabling real-time and continuous monitoring of sweat pH and lactate. This non-invasive sensing platform might open a new avenue for personal health monitoring and medical diagnosis as well as for determining of the physiological conditions of endurance athletes.
Collapse
Affiliation(s)
- Nadtinan Promphet
- Nanoscience and Technology Interdisciplinary Program, Graduate School, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok 10330, Thailand
| | - Pranee Rattanawaleedirojn
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand
| | - Krisana Siralertmukul
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand
| | - Niphaphun Soatthiyanon
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand
| | - Pranut Potiyaraj
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand
| | - Chusak Thanawattano
- National Electronics and Computer Technology Center (NECTEC), Pathumthani 12120, Thailand
| | - Juan P Hinestroza
- Department of Fiber Science, College of Human Ecology, Cornell University, Ithaca, NY 14850, United States
| | - Nadnudda Rodthongkum
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand.
| |
Collapse
|
47
|
Dossi N, Toniolo R, Terzi F, Sdrigotti N, Tubaro F, Bontempelli G. A cotton thread fluidic device with a wall-jet pencil-drawn paper based dual electrode detector. Anal Chim Acta 2018; 1040:74-80. [DOI: 10.1016/j.aca.2018.06.061] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 06/21/2018] [Accepted: 06/22/2018] [Indexed: 10/28/2022]
|
48
|
Neris NM, Guevara RD, Gonzalez A, Gomez FA. 3D Multilayered paper‐ and thread/paper‐based microfluidic devices for bioassays. Electrophoresis 2018; 40:296-303. [DOI: 10.1002/elps.201800383] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 10/29/2018] [Accepted: 10/30/2018] [Indexed: 11/09/2022]
Affiliation(s)
- Natalia M. Neris
- Department of Chemistry and Biochemistry California State University 5151 State University Drive Los Angeles California 90032–8202 USA
| | - Ricardo D. Guevara
- Department of Chemistry and Biochemistry California State University 5151 State University Drive Los Angeles California 90032–8202 USA
| | - Ariana Gonzalez
- Department of Chemistry and Biochemistry California State University 5151 State University Drive Los Angeles California 90032–8202 USA
| | - Frank A. Gomez
- Department of Chemistry and Biochemistry California State University 5151 State University Drive Los Angeles California 90032–8202 USA
| |
Collapse
|
49
|
Cabot JM, Macdonald NP, Phung SC, Breadmore MC, Paull B. Fibre-based electrofluidics on low cost versatile 3D printed platforms for solute delivery, separations and diagnostics; from small molecules to intact cells. Analyst 2018; 141:6422-6431. [PMID: 27786314 DOI: 10.1039/c6an01515h] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
A novel and effective fibre-based microfluidic methodology was developed to move and isolate charged solutes, biomolecules, and intact bacterial cells, based upon a novel multi-functional 3D printed supporting platform, with potential applications in the fields of microfluidics and biodiagnostics. Various on-fibre electrophoretic techniques are demonstrated to separate, pre-concentrate, move, split, or cut and collect the isolated zones of target solutes, including proteins and live bacterial cells. The use of knotting to link different fibre materials, and the unique ability of this approach to physically concentrate solutes in different locations are shown such that the concentrated solutes can be physically isolated and easily transferred to other fibres. Application of this novel fibre-based technique within a potential diagnostic platform for urinary tract infection is shown, together with the post-electrophoretic incubation of live bacterial cells, demonstrating the cell survival following on-fibre electrophoretic concentration.
Collapse
Affiliation(s)
- Joan M Cabot
- ARC Centre of Excellence for Electromaterials Science (ACES), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia. and Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| | - Niall P Macdonald
- ARC Centre of Excellence for Electromaterials Science (ACES), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia. and Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| | - Sui C Phung
- Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| | - Michael C Breadmore
- ARC Centre of Excellence for Electromaterials Science (ACES), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia. and Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| | - Brett Paull
- ARC Centre of Excellence for Electromaterials Science (ACES), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia. and Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, TAS 7001, Australia
| |
Collapse
|
50
|
Gaines M, Gonzalez-Guerrero MJ, Uchida K, Gomez FA. Microfluidic thread-based electrode system to detect glucose and acetylthiocholine. Electrophoresis 2018; 39:3082-3086. [PMID: 30232815 DOI: 10.1002/elps.201800348] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 09/05/2018] [Accepted: 09/11/2018] [Indexed: 11/07/2022]
Abstract
A reusable and simple to fabricate electrochemical sensor for the detection of glucose and acetylthiocholine using thread-based electrodes and nylon thread is described. The fabrication of the device consisted of two steps. First, three nylon-based electrodes (reference, working, and counter) were painted with one layer of conductive inks (silver and carbon ink, or silver/silver chloride ink). The electrodes were taped onto parafilm, and a piece of white nylon thread was wrapped around each electrode connecting the three electrodes. For the glucose system, a PBS solution containing glucose oxidase (GOx) (10 mg/mL), and potassium ferricyanide (K3 [Fe(CN)6 ]) (10 mg/mL) as mediator, was dried onto the thread, and increasing concentrations of glucose (0-15 mM) was added to the thread and measured by cyclic voltammetry (CV). The current output from the glucose oxidation was proportional to the concentration of glucose. For the second system, a solution of acetylcholinesterase (AChE) (0.08 U/mL) in PBS was added to the nylon thread, and increasing concentrations of acetylthiocholine (ATC) (0-9.84 mg/mL) was added and measured by CV. The current output from the oxidation of thiocholine (produced by AChE reacting with ATC) was proportional to the concentrations of ATC added to the thread. From both systems, a graph of current output versus substrate concentration was produced and fitted with a linear regression line that gave R2 values of 0.985 (GOX /glucose) and 0.995 (AChE/ATC).
Collapse
Affiliation(s)
- Michelle Gaines
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| | | | - Kathryn Uchida
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| | - Frank A Gomez
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| |
Collapse
|