1
|
Electrokinetic separation of cfDNA in insulator-based dielectrophoresis systems: a linear model of cfDNA and investigation of effective parameters. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2022; 34:355101. [PMID: 35381587 DOI: 10.1088/1361-648x/ac6476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Accepted: 04/05/2022] [Indexed: 06/14/2023]
Abstract
In this study, a comprehensive numerical simulation was done to investigate the electrokinetic translocation of cfDNA molecule as well as the possibility of its detection and separation in insulator based dielectrophoresis (iDEP) systems. Modeling was done for the first time by solving the Poisson equation for the electrical potential, Naiver-Stokes (NS) equation for the fluid flow and energy equation for the heat transfer in the system and considering a coarse-grained bead-spring model to describe the conformational and geometrical changes of cfDNA molecule. The effect of the geometrical parameters of the system, the initial orientation of the molecule, electrical conductivity of the solution and zeta potential of the wall was investigated on the translocation and the minimum voltage required for cfDNA trapping. When the ratio of the inlet height to the constriction zone height is large enough, cfDNA molecules cannot pass through the nanopore and trap in the constriction zone. Also, it was found that the electrical conductivity of the solution is a limiting parameter to directly isolate cfDNA from pure plasma without dilution due to significant increase in the temperature of the system. Our results demonstrate the enormous potential of iDEP systems for rapid detection of cfDNA from diluted plasma under special electrical potential and geometrical parameters of the iDEP systems.
Collapse
|
2
|
A 3D-ACEK/SERS system for highly efficient and selectable electrokinetic bacteria concentration/detection/ antibiotic-susceptibility-test on whole blood. Biosens Bioelectron 2022; 197:113740. [PMID: 34785491 DOI: 10.1016/j.bios.2021.113740] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 09/22/2021] [Accepted: 10/25/2021] [Indexed: 11/18/2022]
Abstract
This study demonstrates a novel multi-functional microfluidic system, designated three dimensional Alternative Current Electrokinetic/Surface Enhanced Raman Scattering (3D-ACEK/SERS), which can concentrate bacteria from whole blood, identify bacterial species, and determine antibiotic susceptibilities of the bacteria rapidly. The system consists of a hybrid electrokinetic mechanism, integrating AC-electroosmosis (AC-EO) and dielectrophoresis (DEP) that allows thousand-fold concentration of bacteria, including S. aureus, Escherichia coli, and Chryseobacterium indologenes, in the center of an electrode with a wide range of working distance (hundreds to thousands of μm), while exclusion of blood cells through negative DEP forces. This microchip employs SERS assay to determine the identity of the concentrated bacteria in approximately 2 min with a limit of detection of 3 CFU/ml, 5 orders of magnitude lower than that using standard centrifugation-purification process. Finally, label-free antibiotic susceptibility testing has been successfully demonstrated on the platform using both antibiotic-sensitive and multidrug-resistant bacterial strains illustrating a potential utility of the system to clinical applications.
Collapse
|
3
|
Multiplexed detection of respiratory pathogens with a portable analyzer in a "raw-sample-in and answer-out" manner. MICROSYSTEMS & NANOENGINEERING 2021; 7:94. [PMID: 34840805 PMCID: PMC8608563 DOI: 10.1038/s41378-021-00321-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 09/10/2021] [Accepted: 10/08/2021] [Indexed: 02/05/2023]
Abstract
Coronavirus disease 2019 (COVID-19) has emerged, rapidly spread and caused significant morbidity and mortality worldwide. There is an urgent public health need for rapid, sensitive, specific, and on-site diagnostic tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. In this study, a fully integrated and portable analyzer was developed to detect SARS-CoV-2 from swab samples based on solid-phase nucleic acid extraction and reverse transcription loop-mediated isothermal amplification (RT-LAMP). The swab can be directly inserted into a cassette for multiplexed detection of respiratory pathogens without pre-preparation. The overall detection process, including swab rinsing, magnetic bead-based nucleic acid extraction, and 8-plex real-time RT-LAMP, can be automatically performed in the cassette within 80 min. The functionality of the cassette was validated by detecting the presence of a SARS-CoV-2 pseudovirus and three other respiratory pathogens, i.e., Klebsiella pneumoniae, Pseudomonas aeruginosa, and Stenotrophomonas maltophilia. The limit of detection (LoD) for the SARS-CoV-2 pseudovirus was 2.5 copies/μL with both primer sets (N gene and ORF1ab gene), and the three bacterial species were successfully detected with an LoD of 2.5 colony-forming units (CFU)/μL in 800 μL of swab rinse. Thus, the analyzer developed in this study has the potential to rapidly detect SARS-CoV-2 and other respiratory pathogens on site in a “raw-sample-in and answer-out” manner.
Collapse
|
4
|
Portable point-of-care diagnostic devices: an updated review. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:5418-5435. [PMID: 34787609 DOI: 10.1039/d1ay01643a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The global pandemic caused by the SARS-CoV-2 (COVID) virus indiscriminately impacted people worldwide with unquantifiable and severe impacts on all aspects of our lives, regardless of socioeconomic status. The pandemic brought to light the very real possibility of pathogens changing and shaping the way we live, and our lack of preparedness to deal with viral/bacterial outbreaks. Importantly, the quick detection of pathogens can help prevent and control the spread of disease, making the importance of diagnostic techniques undeniable. Point-of-care diagnostics started as a supplement to standard lab-based diagnostics, and are gradually becoming mainstream. Because of this, and their importance in detecting pathogens (especially in the developing world), their development has accelerated at an unprecedented rate. In this review, we highlight some important and recent examples of point-of-care diagnostics for detecting nucleic acids, proteins, bacteria, and other biomarkers, with the intent of making apparent their positive impact on society and human health.
Collapse
|
5
|
Fluid-Screen as a real time dielectrophoretic method for universal microbial capture. Sci Rep 2021; 11:22222. [PMID: 34782647 PMCID: PMC8594773 DOI: 10.1038/s41598-021-01600-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Accepted: 10/20/2021] [Indexed: 12/11/2022] Open
Abstract
Bacterial culture methods, e.g. Plate Counting Method (PCM), are a gold standard in the assessment of microbial contamination in multitude of human industries. They are however slow, labor intensive, and prone to manual errors. Dielectrophoresis (DEP) has shown great promise for particle separation for decades; however, it has not yet been widely applied in routine laboratory setting. This paper provides an overview of a new DEP microbial capture and separation method called Fluid-Screen (FS), that achieves very fast, efficient, reliable and repeatable capture and separation of microbial cells. Method verification experiments demonstrated that the FS system captured 100% of bacteria in test samples, a capture efficiency much higher than previously reported for similar technology. Data generated supports the superiority of the FS method as compared to the established Plate Counting Method (PCM), that is routinely used to detect bacterial contamination in healthcare, pharmacological and food industries. We demonstrate that the FS method is universal and can capture and separate different species of bacteria and fungi to viruses, from various sample matrices (i.e. human red blood cells, mammalian cells).
Collapse
|
6
|
A Highly Automated Mobile Laboratory for On-site Molecular Diagnostics in the COVID-19 Pandemic. Clin Chem 2021; 67:672-683. [PMID: 33788940 PMCID: PMC8083610 DOI: 10.1093/clinchem/hvab027] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Accepted: 02/01/2021] [Indexed: 02/05/2023]
Abstract
BACKGROUND Infectious disease outbreaks such as the COVID-19 (coronavirus disease 2019) pandemic call for rapid response and complete screening of the suspected community population to identify potential carriers of pathogens. Central laboratories rely on time-consuming sample collection methods that are rarely available in resource-limited settings. METHODS We present a highly automated and fully integrated mobile laboratory for fast deployment in response to infectious disease outbreaks. The mobile laboratory was equipped with a 6-axis robot arm for automated oropharyngeal swab specimen collection; virus in the collected specimen was inactivated rapidly using an infrared heating module. Nucleic acid extraction and nested isothermal amplification were performed by a "sample in, answer out" laboratory-on-a-chip system, and the result was automatically reported by the onboard information platform. Each module was evaluated using pseudovirus or clinical samples. RESULTS The mobile laboratory was stand-alone and self-sustaining and capable of on-site specimen collection, inactivation, analysis, and reporting. The automated sampling robot arm achieved sampling efficiency comparable to manual collection. The collected samples were inactivated in as short as 12 min with efficiency comparable to a water bath without damage to nucleic acid integrity. The limit of detection of the integrated microfluidic nucleic acid analyzer reached 150 copies/mL within 45 min. Clinical evaluation of the onboard microfluidic nucleic acid analyzer demonstrated good consistency with reverse transcription quantitative PCR with a κ coefficient of 0.979. CONCLUSIONS The mobile laboratory provides a promising solution for fast deployment of medical diagnostic resources at critical junctions of infectious disease outbreaks and facilitates local containment of SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) transmission.
Collapse
|
7
|
Field enhancement in microfluidic semiconductor nanowire array. BIOMICROFLUIDICS 2020; 14:064102. [PMID: 33163137 PMCID: PMC7609134 DOI: 10.1063/5.0028899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Accepted: 10/15/2020] [Indexed: 06/11/2023]
Abstract
Nano-material integrated microfluidic platforms are increasingly being considered to accelerate biological sample preparation and molecular diagnostics. A major challenge in this context is the generation of high electric fields for electroporation of cell membranes. In this paper, we have studied a novel mechanism of generating a high electric field in the microfluidic channels by using an array of semiconductor nanowires. When an electrostatic field is applied across a semiconductor nanowire array, the electric field is localized near the nanowires and the field strength is higher than what was reported previously with various other micro-geometries. Nanowires made of ZnO, Si, and Si-SiO2 and their orientation and array spacing are considered design parameters. It is observed that for a given ratio of the spacing between nanowires to the diameter, the electric field enhancement near the edges of ZnO nanowires is nearly 30 times higher compared to Si or Si-SiO2 nanowire arrays. This enhancement is a combined effect of the unique geometry with a pointed tip with a hexagonal cross section, the piezoelectric and the spontaneous polarization in the ZnO nanowires, and the electro-kinetics of the interface fluid. Considering the field localization phenomena, the trajectories of E. coli cells in the channel are analyzed. For a given inter-nanowire spacing and an applied electric field, the channels with ZnO nanowire arrays have a greater probability of cell lysis in comparison to Si-based nanowire arrays. Detailed correlations between the cell lysis probability with the inter-nanowire spacing and the applied electric field are reported.
Collapse
|
8
|
Review: Dielectrophoresis in cell characterization. Electrophoresis 2020; 41:1915-1930. [DOI: 10.1002/elps.202000034] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2020] [Revised: 05/31/2020] [Accepted: 07/14/2020] [Indexed: 12/23/2022]
|
9
|
An enhanced centrifugation-assisted lateral flow immunoassay for the point-of-care detection of protein biomarkers. LAB ON A CHIP 2020; 20:2626-2634. [PMID: 32567627 DOI: 10.1039/d0lc00518e] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Protein biomarkers are widely used for disease diagnosis, but the current detection methods utilized in centralized laboratories are mainly based on enzyme-linked immunosorbent assay (ELISA)-derived sandwich-type immunoassays such as chemiluminescent or electrochemiluminescent immunoassays, which suffer from long detection times and cumbersome instruments. For the point-of-care (POC) detection of protein biomarkers, various test strips for lateral flow immunoassay (LFIA) have been manufactured, but their detection sensitivities and capabilities for raw samples are limited. In this study, an enhanced centrifugation-assisted lateral flow immunoassay (ECLFIA) was established to rapidly detect protein biomarkers in whole blood with a higher sensitivity than LFIA. By inserting a nitrocellulose membrane into a centrifugal disc, fully automated operations, including sample preparation, active lateral flow actuation, washing, and signal amplification, which could hardly be performed in conventional LFIA, were enabled on the centrifugal platform for ECLFIA. The entire process for detecting human prostate specific antigen (PSA) in a drop of blood (20 μL) could be completed in 15 min. The limit of detection for our ECLFIA system was 0.028 ng mL-1, showing a 21.4-fold improvement compared to that of LFIA. Moreover, this system was utilized to detect PSA in 34 clinical samples. The results were compared to those measured using a commercial instrument used in the hospital, and a good correlation coefficient of 0.986 was obtained, demonstrating the practicality of this ECLFIA system. In summary, the ECLFIA system established in this study can be an efficient tool for the POC detection of protein biomarkers with comprehensive advantages in sensitivity, simplicity and speed.
Collapse
|
10
|
Enhancing the Sensitivity of Lateral Flow Immunoassay by Centrifugation-Assisted Flow Control. Anal Chem 2019; 91:4814-4820. [PMID: 30835106 DOI: 10.1021/acs.analchem.9b00421] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Lateral flow immunoassay (LFIA) is widely used but is limited by its sensitivity. In this study, a novel centrifugation-assisted lateral flow immunoassay (CLFIA) was proposed that had enhanced sensitivity compared to traditional LFIA based on test strips. For CLFIA, a vaulted piece of nitrocellulose membrane was prepared and inserted into a centrifugal disc. Powered by the centrifugal force, the sample volume on the disc was not limited and the flow rate of the reaction fluid was steady and adjustable at different rotation speeds. It was found that lower rotation speeds and larger sample volumes resulted in greater signal intensity in the nitrocellulose membrane as well as higher sensitivity, indicating that the actively controlled flow on the disc allowed for sensitivity enhancement of CLFIA. To operate CLFIA on the centrifugal disc, a portable and cost-effective operating device was constructed to rotate the disc with a stepper motor and collect the results with a smartphone. The proposed method was successfully applied to detect prostate specific antigen (PSA) in human serum. Standard curves were established for CLFIA and LFIA, and both had correlation coefficients of up to 0.99. Under optimal conditions (1500 rpm rotation speed, 120 μL sample volume), the detection limit of CLFIA reached 0.067 ng/mL, showing a 6.2-fold improvement in sensitivity compared to that of LFIA. With clinical serum samples, a good correlation was observed between PSA concentrations measured by CLFIA and by a bulky commercial instrument in hospital. In summary, this portable, cost-effective, and easy-to-use system holds great promise for biomarker detection with enhanced sensitivity compared to traditional LFIA.
Collapse
|
11
|
Microfluidic-Based Single-Cell Study: Current Status and Future Perspective. Molecules 2018; 23:E2347. [PMID: 30217082 PMCID: PMC6225124 DOI: 10.3390/molecules23092347] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2018] [Revised: 09/05/2018] [Accepted: 09/09/2018] [Indexed: 01/29/2023] Open
Abstract
Investigation of cell behavior under different environments and manual operations can give information in specific cellular processes. Among all cell-based analysis, single-cell study occupies a peculiar position, while it can avoid the interaction effect within cell groups and provide more precise information. Microfluidic devices have played an increasingly important role in the field of single-cell study owing to their advantages: high efficiency, easy operation, and low cost. In this review, the applications of polymer-based microfluidics on cell manipulation, cell treatment, and cell analysis at single-cell level are detailed summarized. Moreover, three mainly types of manufacturing methods, i.e., replication, photodefining, and soft lithography methods for polymer-based microfluidics are also discussed.
Collapse
|
12
|
Filter-based isolation, enrichment, and characterization of circulating tumor cells. Biotechnol Bioeng 2018; 115:2504-2529. [DOI: 10.1002/bit.26787] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2018] [Revised: 06/25/2018] [Accepted: 06/28/2018] [Indexed: 01/12/2023]
|
13
|
DNA multi-bit non-volatile memory and bit-shifting operations using addressable electrode arrays and electric field-induced hybridization. Nat Commun 2018; 9:281. [PMID: 29348493 PMCID: PMC5773625 DOI: 10.1038/s41467-017-02705-8] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2017] [Accepted: 12/20/2017] [Indexed: 11/09/2022] Open
Abstract
DNA has been employed to either store digital information or to perform parallel molecular computing. Relatively unexplored is the ability to combine DNA-based memory and logical operations in a single platform. Here, we show a DNA tri-level cell non-volatile memory system capable of parallel random-access writing of memory and bit shifting operations. A microchip with an array of individually addressable electrodes was employed to enable random access of the memory cells using electric fields. Three segments on a DNA template molecule were used to encode three data bits. Rapid writing of data bits was enabled by electric field-induced hybridization of fluorescently labeled complementary probes and the data bits were read by fluorescence imaging. We demonstrated the rapid parallel writing and reading of 8 (23) combinations of 3-bit memory data and bit shifting operations by electric field-induced strand displacement. Our system may find potential applications in DNA-based memory and computations. DNA based technology holds promise for non-volatile memory and computational tasks, yet the relatively slow hybridization kinetics remain a bottleneck. Here, Song et al. have developed an electric field-induced hybridization platform that can speed up multi-bit memory and logic operations.
Collapse
|
14
|
Introduction. DEVELOPMENT OF A FULLY INTEGRATED “SAMPLE-IN-ANSWER-OUT” SYSTEM FOR AUTOMATIC GENETIC ANALYSIS 2018:1-30. [DOI: 10.1007/978-981-10-4753-4_1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
15
|
Continuous and High-Throughput Electromechanical Lysis of Bacterial Pathogens Using Ion Concentration Polarization. Anal Chem 2017; 90:872-880. [PMID: 29193960 DOI: 10.1021/acs.analchem.7b03746] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Electrical lysis of mammalian cells has been a preferred method in microfluidic platforms because of its simple implementation and rapid recovery of lysates without additional reagents. However, bacterial lysis typically requires at least a 10-fold higher electric field (∼10 kV/cm), resulting in various technical difficulties. Here, we present a novel, low-field-enabled electromechanical lysis mechanism of bacterial cells using electroconvective vortices near ion selective materials. The vortex-assisted lysis only requires a field strength of ∼100 V/cm, yet it efficiently recovers proteins and nucleic acids from a variety of pathogenic bacteria and operates in a continuous and ultrahigh-throughput (>1 mL/min) manner. Therefore, we believe that the electromechanical lysis will not only facilitate microfluidic bacterial sensing and analysis but also various high-volume applications such as the energy-efficient recovery of valuable metabolites in biorefinery pharmaceutical industries and the disinfection of large-volume fluid for the water and food industries.
Collapse
|
16
|
Scalable Device for Automated Microbial Electroporation in a Digital Microfluidic Platform. ACS Synth Biol 2017; 6:1701-1709. [PMID: 28569062 DOI: 10.1021/acssynbio.7b00007] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Electrowetting-on-dielectric (EWD) digital microfluidic laboratory-on-a-chip platforms demonstrate excellent performance in automating labor-intensive protocols. When coupled with an on-chip electroporation capability, these systems hold promise for streamlining cumbersome processes such as multiplex automated genome engineering (MAGE). We integrated a single Ti:Au electroporation electrode into an otherwise standard parallel-plate EWD geometry to enable high-efficiency transformation of Escherichia coli with reporter plasmid DNA in a 200 nL droplet. Test devices exhibited robust operation with more than 10 transformation experiments performed per device without cross-contamination or failure. Despite intrinsic electric-field nonuniformity present in the EP/EWD device, the peak on-chip transformation efficiency was measured to be 8.6 ± 1.0 × 108 cfu·μg-1 for an average applied electric field strength of 2.25 ± 0.50 kV·mm-1. Cell survival and transformation fractions at this electroporation pulse strength were found to be 1.5 ± 0.3 and 2.3 ± 0.1%, respectively. Our work expands the EWD toolkit to include on-chip microbial electroporation and opens the possibility of scaling advanced genome engineering methods, like MAGE, into the submicroliter regime.
Collapse
|
17
|
High-throughput, low-loss, low-cost, and label-free cell separation using electrophysiology-activated cell enrichment. Proc Natl Acad Sci U S A 2017; 114:4591-4596. [PMID: 28408395 DOI: 10.1073/pnas.1700773114] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Currently, cell separation occurs almost exclusively by density gradient methods and by fluorescence- and magnetic-activated cell sorting (FACS/MACS). These variously suffer from lack of specificity, high cell loss, use of labels, and high capital/operating cost. We present a dielectrophoresis (DEP)-based cell-separation method, using 3D electrodes on a low-cost disposable chip; one cell type is allowed to pass through the chip whereas the other is retained and subsequently recovered. The method advances usability and throughput of DEP separation by orders of magnitude in throughput, efficiency, purity, recovery (cells arriving in the correct output fraction), cell losses (those which are unaccounted for at the end of the separation), and cost. The system was evaluated using three example separations: live and dead yeast; human cancer cells/red blood cells; and rodent fibroblasts/red blood cells. A single-pass protocol can enrich cells with cell recovery of up to 91.3% at over 300,000 cells per second with >3% cell loss. A two-pass protocol can process 300,000,000 cells in under 30 min, with cell recovery of up to 96.4% and cell losses below 5%, an effective processing rate >160,000 cells per second. A three-step protocol is shown to be effective for removal of 99.1% of RBCs spiked with 1% cancer cells while maintaining a processing rate of ∼170,000 cells per second. Furthermore, the self-contained and low-cost nature of the separator device means that it has potential application in low-contamination applications such as cell therapies, where good manufacturing practice compatibility is of paramount importance.
Collapse
|
18
|
Automated Combinatorial Process for Nanofabrication of Structures Using Bioderivatized Nanoparticles. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.jala.2007.05.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A fully automated electronic microarray control system (Nanochip 400 System) was used to carry out a combinatorial process to determine optimal conditions for fabricating higher order three-dimensional nanoparticle structures. Structures with up to 40 layers of bioderivatized nanoparticles were fabricated on a 400-test site CMOS microarray using the automated Nanochip 400 System. Reconfigurable electric fields produced on the surface of the CMOS microarray device actively transport, concentrate, and promote binding of 40 nm biotin- and streptavidin-derivatized nanoparticles to selected test sites on the microarray surface. The overall fabrication process including nanoparticle reagent delivery to the microarray device, electronic control of the CMOS microarray and the optical/fluorescent detection, and monitoring of nanoparticle layering are entirely controlled by the Nanochip 400 System. The automated nanoparticle layering process takes about 2 minutes per layer, with 10–20 seconds required for the electronic addressing and binding of nanoparticles, and roughly 60 seconds for washing. The addressing and building process is monitored by changes in fluorescence intensity as each nanoparticle layer is deposited. The final multilayered 3D structures are about 2 μm in thickness and 55 μm in diameter. Multilayer nanoparticle structures and control sites on the microarray were verified by SEM analysis.
Collapse
|
19
|
High-k Dielectric Passivation: Novel Considerations Enabling Cell Specific Lysis Induced by Electric Fields. ACS APPLIED MATERIALS & INTERFACES 2016; 8:21228-21235. [PMID: 27466697 DOI: 10.1021/acsami.6b06927] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A better understanding of the electrodynamic behavior of cells interacting with electric fields would allow for novel scientific insights and would lead to the next generation of cell manipulation, diagnostics, and treatment. Here, we introduce a promising electrode design by using metal oxide high-k dielectric passivation. The thermally generated dielectric passivation layer enables efficient electric field coupling to the fluid sample comprising cells while simultaneously decoupling the electrode ohmically from the electrolyte, allowing for better control and adjustability of electric field effects due to reduced electrochemical reactions at the electrode surface. This approach demonstrates cell-size specific lysis with electric fields in a microfluidic flow-through design resulting in 99.8% blood cell lysis at 6 s exposure without affecting the viability of Gram-positive and Gram-negative bacterial spike-ins. The advantages of this new approach can support next-generation investigations of electrodynamics in biological systems and their exploitation for cell manipulation in multiple fields of medicine, life science, and industry.
Collapse
|
20
|
Electrokinetic acceleration of DNA hybridization in microsystems. Talanta 2015; 138:149-154. [DOI: 10.1016/j.talanta.2015.02.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2014] [Revised: 02/10/2015] [Accepted: 02/14/2015] [Indexed: 11/22/2022]
|
21
|
Device for dielectrophoretic separation and collection of nanoparticles and DNA under high conductance conditions. Electrophoresis 2015; 36:1107-14. [DOI: 10.1002/elps.201400507] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Revised: 02/07/2015] [Accepted: 02/19/2015] [Indexed: 11/09/2022]
|
22
|
An automated microfluidic system for single-stranded DNA preparation and magnetic bead-based microarray analysis. BIOMICROFLUIDICS 2015; 9:024102. [PMID: 25825617 PMCID: PMC4352165 DOI: 10.1063/1.4914024] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2015] [Accepted: 02/18/2015] [Indexed: 05/25/2023]
Abstract
We present an integrated microfluidic device capable of performing single-stranded DNA (ssDNA) preparation and magnetic bead-based microarray analysis with a white-light detection for detecting mutations that account for hereditary hearing loss. The entire operation process, which includes loading of streptavidin-coated magnetic beads (MBs) and biotin-labeled polymerase chain reaction products, active dispersion of the MBs with DNA for binding, alkaline denaturation of DNA, dynamic hybridization of the bead-labeled ssDNA to a tag array, and white-light detection, can all be automatically accomplished in a single chamber of the microchip, which was operated on a self-contained instrument with all the necessary components for thermal control, fluidic control, and detection. Two novel mixing valves with embedded polydimethylsiloxane membranes, which can alternately generate a 3-μl pulse flow at a peak rate of around 160 mm/s, were integrated into the chip for thoroughly dispersing magnetic beads in 2 min. The binding efficiency of biotinylated oligonucleotides to beads was measured to be 80.6% of that obtained in a tube with the conventional method. To critically test the performance of this automated microsystem, we employed a commercial microarray-based detection kit for detecting nine mutation loci that account for hereditary hearing loss. The limit of detection of the microsystem was determined as 2.5 ng of input K562 standard genomic DNA using this kit. In addition, four blood samples obtained from persons with mutations were all correctly typed by our system in less than 45 min per run. The fully automated, "amplicon-in-answer-out" operation, together with the white-light detection, makes our system an excellent platform for low-cost, rapid genotyping in clinical diagnosis.
Collapse
|
23
|
Rapidly prototyped multi-scale electrodes to minimize the voltage requirements for bacterial cell lysis. Analyst 2015; 140:1599-608. [PMID: 25597363 DOI: 10.1039/c4an02150a] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Lab-on-a-chip systems used for nucleic acid based detection of bacteria rely on bacterial lysis for the release of cellular material. Although electrical lysis devices can be miniaturized for on-chip integration and reagent-free lysis, they often suffer from high voltage requirements, and rely on the use of off-chip voltage supplies. To overcome this barrier, we developed a rapid prototyping method for creating multi-scale electrodes that are structurally tuned for lowering the voltage needed for electrical bacterial lysis. These three-dimensional multi-scale electrodes – with micron scale reaction areas and nanoscale features – are fabricated using benchtop methods including craft cutting, polymer-induced wrinkling, and electrodeposition, which enable a lysis device to be designed, fabricated, and optimized in a matter of hours. These tunable electrodes show superior behaviour compared to lithographically-prepared electrodes in terms of lysis efficiency and voltage requirement. Successful extraction of nucleic acids from bacterial samples processed by these electrodes demonstrates the potential for these rapidly prototyped devices to be integrated within practical lab-on-a-chip systems.
Collapse
|
24
|
An integrated microfluidic device utilizing dielectrophoresis and multiplex array PCR for point-of-care detection of pathogens. LAB ON A CHIP 2014; 14:3917-3924. [PMID: 25082458 DOI: 10.1039/c4lc00669k] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The early identification of causative pathogens in clinical specimens that require no cultivation is essential for directing evidence-based antimicrobial treatments in resource limited settings. Here, we describe an integrated microfluidic device for the rapid identification of pathogens in complex physiological matrices such as blood. The device was designed and fabricated using SlipChip technologies, which integrated four channels processing independent samples and identifying up to twenty different pathogens. Briefly, diluted whole human blood samples were directly injected into the device for analysis. The pathogens were extracted from the blood by dielectrophoresis, retained in an array of grooves, and identified by multiplex array PCR in nanoliter volumes with end-point fluorescence detection. The universality of the dielectrophoretic separation of pathogens from physiological fluids was evaluated with a panel of clinical isolates covering predominant bacterial and fungal species. Using this system, we simultaneously identified Pseudomonas aeruginosa, Staphylococcus aureus and Escherichia coli O157:H7 within 3 h. In addition to the prompt diagnosis of bloodstream infections, this method may also be utilized for differentiating microorganisms in contaminated water and environmental samples.
Collapse
|
25
|
Label-free electrochemical detection of human methyltransferase from tumors. Proc Natl Acad Sci U S A 2014; 111:14985-9. [PMID: 25288757 DOI: 10.1073/pnas.1417351111] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
The role of abnormal DNA methyltransferase activity in the development and progression of cancer is an essential and rapidly growing area of research, both for improved diagnosis and treatment. However, current technologies for the assessment of methyltransferase activity, particularly from crude tumor samples, limit this work because they rely on radioactivity or fluorescence and require bulky instrumentation. Here, we report an electrochemical platform that overcomes these limitations for the label-free detection of human DNA(cytosine-5)-methyltransferase1 (DNMT1) methyltransferase activity, enabling measurements from crude cultured colorectal cancer cell lysates (HCT116) and biopsied tumor tissues. Our multiplexed detection system involving patterning and detection from a secondary electrode array combines low-density DNA monolayer patterning and electrocatalytically amplified DNA charge transport chemistry to measure selectively and sensitively DNMT1 activity within these complex and congested cellular samples. Based on differences in DNMT1 activity measured with this assay, we distinguish colorectal tumor tissue from healthy adjacent tissue, illustrating the effectiveness of this two-electrode platform for clinical applications.
Collapse
|
26
|
Abstract
The precise rotation of suspended cells is one of the many fundamental manipulations used in a wide range of biotechnological applications such as cell injection and enucleation in nuclear transfer (NT) cloning. Noticeably scarce among the existing rotation techniques is the three-dimensional (3D) rotation of cells on a single chip. Here we present an alternating current (ac) induced electric field-based biochip platform, which has an open-top sub-mm square chamber enclosed by four sidewall electrodes and two bottom electrodes, to achieve rotation about the two axes, thus 3D cell rotation. By applying an ac potential to the four sidewall electrodes, an in-plane (yaw) rotating electric field is generated and in-plane rotation is achieved. Similarly, by applying an ac potential to two opposite sidewall electrodes and the two bottom electrodes, an out-of-plane (pitch) rotating electric field is generated and rolling rotation is achieved. As a prompt proof-of-concept, bottom electrodes were constructed with transparent indium tin oxide (ITO) using the standard lift-off process and the sidewall electrodes were constructed using a low-cost micro-milling process and then assembled to form the chip. Through experiments, we demonstrate rotation of bovine oocytes of ~120 μm diameter about two axes, with the capability of controlling the rotation direction and the rate for each axis through control of the ac potential amplitude, frequency, and phase shift, and cell medium conductivity. The maximum observed rotation rate reached nearly 140° s⁻¹, while a consistent rotation rate reached up to 40° s⁻¹. Rotation rate spectra for zona pellucida-intact and zona pellucida-free oocytes were further compared and found to have no effective difference. This simple, transparent, cheap-to-manufacture, and open-top platform allows additional functional modules to be integrated to become a more powerful cell manipulation system.
Collapse
|
27
|
Use of surface enhanced blocking (SEB) electrodes for microbial cell lysis in flow-through devices. PLoS One 2014; 9:e102707. [PMID: 25033080 PMCID: PMC4102548 DOI: 10.1371/journal.pone.0102707] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2014] [Accepted: 06/23/2014] [Indexed: 12/02/2022] Open
Abstract
By simultaneously subjecting microbial cells to high amplitude pulsed electric fields and flash heating of the cell suspension fluid, effective release of intracellular contents was achieved. The synergistic effect of the applied electric field and elevated temperature on cell lysis in a flow-through device was demonstrated for Gram-negative and Gram-positive bacteria, and Mycobacterium species. The resulting lysate is suitable for downstream nucleic acid amplification and detection without requiring further preparation. The lysis chamber employs surface enhanced blocking electrodes which possess an etched micro-structured surface and a thin layer of dielectric metal oxide which provides a large effective area and blocks transmission of electrical current. The surface enhanced blocking electrodes enable simultaneous suppression of the rapid onset of electric field screening in the bulk of the cell suspension medium and avoidance of undesired electrochemical processes at the electrode-electrolyte interface. In addition the blocking layer ensures the robustness of the cell lysis device in applications involving prolonged flow-through processing of the microbial cells.
Collapse
|
28
|
Dielectrophoretic isolation and detection of cancer-related circulating cell-free DNA biomarkers from blood and plasma. Electrophoresis 2014; 35:1828-36. [PMID: 24723219 DOI: 10.1002/elps.201400016] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2014] [Revised: 03/16/2014] [Accepted: 03/18/2014] [Indexed: 12/18/2022]
Abstract
Conventional methods for the isolation of cancer-related circulating cell-free (ccf) DNA from patient blood (plasma) are time consuming and laborious. A DEP approach utilizing a microarray device now allows rapid isolation of ccf-DNA directly from a small volume of unprocessed blood. In this study, the DEP device is used to compare the ccf-DNA isolated directly from whole blood and plasma from 11 chronic lymphocytic leukemia (CLL) patients and one normal individual. Ccf-DNA from both blood and plasma samples was separated into DEP high-field regions, after which cells (blood), proteins, and other biomolecules were removed by a fluidic wash. The concentrated ccf-DNA was detected on-chip by fluorescence, and then eluted for PCR and DNA sequencing. The complete process from blood to PCR required less than 10 min; an additional 15 min was required to obtain plasma from whole blood. Ccf-DNA from the equivalent of 5 μL of CLL blood and 5 μL of plasma was amplified by PCR using Ig heavy-chain variable (IGHV) specific primers to identify the unique IGHV gene expressed by the leukemic B-cell clone. The PCR and DNA sequencing results obtained by DEP from all 11 CLL blood samples and from 8 of the 11 CLL plasma samples were exactly comparable to the DNA sequencing results obtained from genomic DNA isolated from CLL patient leukemic B cells (gold standard).
Collapse
|
29
|
Dielectrophoretic manipulation and separation of microparticles using microarray dot electrodes. SENSORS 2014; 14:6356-69. [PMID: 24705632 PMCID: PMC4029698 DOI: 10.3390/s140406356] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Revised: 03/07/2014] [Accepted: 03/14/2014] [Indexed: 12/27/2022]
Abstract
This paper introduces a dielectrophoretic system for the manipulation and separation of microparticles. The system is composed of five layers and utilizes microarray dot electrodes. We validated our system by conducting size-dependent manipulation and separation experiments on 1, 5 and 15 μm polystyrene particles. Our findings confirm the capability of the proposed device to rapidly and efficiently manipulate and separate microparticles of various dimensions, utilizing positive and negative dielectrophoresis (DEP) effects. Larger size particles were repelled and concentrated in the center of the dot by negative DEP, while the smaller sizes were attracted and collected by the edge of the dot by positive DEP.
Collapse
|
30
|
Rapid (<5 min) identification of pathogen in human blood by electrokinetic concentration and surface-enhanced Raman spectroscopy. Sci Rep 2014; 3:2365. [PMID: 23917638 PMCID: PMC3734443 DOI: 10.1038/srep02365] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2013] [Accepted: 07/15/2013] [Indexed: 01/12/2023] Open
Abstract
This study reports a novel microfluidic platform for rapid and long-ranged concentration of rare-pathogen from human blood for subsequent on-chip surface-enhanced Raman spectroscopy (SERS) identification/discrimination of bacteria based on their detected fingerprints. Using a hybrid electrokinetic mechanism, bacteria can be concentrated at the stagnation area on the SERS-active roughened electrode, while blood cells were excluded away from this region at the center of concentric circular electrodes. This electrokinetic approach performs isolation and concentration of bacteria in about three minutes; the density factor is increased approximately a thousand fold in a local area of ~5000 μm2 from a low bacteria concentration of 5 × 103 CFU/ml. Besides, three genera of bacteria, S. aureus, E. coli, and P. aeruginosa that are found in most of the isolated infections in bacteremia were successfully identified in less than one minute on-chip without the use of any antibody/chemical immobilization and reaction processes.
Collapse
|
31
|
Abstract
Sport and doping are a contradiction in terms, however, doping abuse in sports has been a serious problem for many years. The systematic screening of every athlete for all prohibited drugs should be an indispensable feature of the Olympic Games. The gas chromatography mass spectrometry method is reserved as a reference method, but is limited by its low throughput. The advent of protein chip technology may enable the screening of all athletes for any illegal use of drugs.
Collapse
|
32
|
Robust ZnO nanoparticle embedded memory device using vancomycin conjugate and its biorecognition for electrical charging node. Biosens Bioelectron 2014; 56:33-8. [PMID: 24462828 DOI: 10.1016/j.bios.2013.12.049] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2013] [Revised: 12/09/2013] [Accepted: 12/20/2013] [Indexed: 10/25/2022]
Abstract
Conjugation of antibiotic vancomycin (VAN) on nanoparticles (NPs) has recently initiated novel works in the nanobiotechnology field. In this study, a bioelectronic structure using VAN conjugated zinc oxide (ZnO) NPs as charge storing elements on metal-pentacene-insulator-silicon (MPIS) device is demonstrated. Highly specific molecular recognition between the VAN and membrane protein unit mimicked from VAN-resistant bacteria is employed as the formation mechanism of self-assembly monolayers (SAMs) of ZnO NPs. The insulator surface is modified with the VAN cognate peptide of L-Ala-D-Glu-L-Lys-D-Ala-D-Ala by chemical activator coupling. Hysteretic behaviors in capacitance versus voltage (C-V) curves are obtained for the charged ZnO NPs exhibiting flatband voltage shifts, which demonstrate the charge storage on the VAN conjugated ZnO NPs. The potential perspective of this study will be a tangible progress of biomolecular electronics implemented by the interface between biomolecules and electronics.
Collapse
|
33
|
|
34
|
Abstract
Electroporation is a simple yet powerful technique for breaching the cell membrane barrier. The applications of electroporation can be generally divided into two categories: the release of intracellular proteins, nucleic acids and other metabolites for analysis and the delivery of exogenous reagents such as genes, drugs and nanoparticles with therapeutic purposes or for cellular manipulation. In this review, we go over the basic physics associated with cell electroporation and highlight recent technological advances on microfluidic platforms for conducting electroporation. Within the context of its working mechanism, we summarize the accumulated knowledge on how the parameters of electroporation affect its performance for various tasks. We discuss various strategies and designs for conducting electroporation at the microscale and then focus on analysis of intracellular contents and delivery of exogenous agents as two major applications of the technique. Finally, an outlook for future applications of microfluidic electroporation in increasingly diverse utilities is presented.
Collapse
|
35
|
Nonmonotonous variation of DNA angular separation during asymmetric pulsed field electrophoresis. Electrophoresis 2013; 34:2453-63. [PMID: 23784786 DOI: 10.1002/elps.201300152] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2013] [Revised: 06/07/2013] [Accepted: 06/08/2013] [Indexed: 11/09/2022]
Abstract
Asymmetric pulsed field electrophoresis within crystalline arrays is used to generate angular separation of DNA molecules. Four regimes of the frequency response are observed, a low frequency rise in angular separation, a plateau, a subsequent decline, and a second plateau at higher frequencies. It is shown that the frequency response for different sized DNA is governed by the relation between pulse time and the reorientation time of DNA molecules. The decline in angular separation at higher frequencies has not previously been analyzed. Real-time videos of single DNA molecules migrating under high frequency-pulsed electric field show the molecules no longer follow the head to tail switching, ratchet mechanism seen at lower frequencies. Once the pulse period is shorter than the reorientation time, the migration mechanism changes significantly. The molecule reptates along the average direction of the two electric fields, which reduces the angular separation. A freely jointed chain model of DNA is developed where the porous structure is represented with a hexagonal array of obstacles. The model qualitatively predicts the variation of DNA angular separation with respect to frequency.
Collapse
|
36
|
Dielectrophoretic isolation and detection of cfc-DNA nanoparticulate biomarkers and virus from blood. Electrophoresis 2013; 34:1076-84. [PMID: 23436471 PMCID: PMC4517469 DOI: 10.1002/elps.201200444] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2012] [Revised: 10/23/2012] [Accepted: 11/05/2012] [Indexed: 12/18/2022]
Abstract
Dielectrophoretic (DEP) microarray devices allow important cellular nanoparticulate biomarkers and virus to be rapidly isolated, concentrated, and detected directly from clinical and biological samples. A variety of submicron nanoparticulate entities including cell free circulating (cfc) DNA, mitochondria, and virus can be isolated into DEP high-field areas on microelectrodes, while blood cells and other micron-size entities become isolated into DEP low-field areas between the microelectrodes. The nanoparticulate entities are held in the DEP high-field areas while cells are washed away along with proteins and other small molecules that are not affected by the DEP electric fields. DEP carried out on 20 μL of whole blood obtained from chronic lymphocytic leukemia patients showed a considerable amount of SYBR Green stained DNA fluorescent material concentrated in the DEP high-field regions. Whole blood obtained from healthy individuals showed little or no fluorescent DNA materials in the DEP high-field regions. Fluorescent T7 bacteriophage virus could be isolated directly from blood samples, and fluorescently stained mitochondria could be isolated from biological buffer samples. Using newer DEP microarray devices, high-molecular-weight DNA could be isolated from serum and detected at levels as low as 8-16 ng/mL.
Collapse
|
37
|
Abstract
Single cell study is gaining importance because of the cell-to-cell variation that exists within cell population, even after significant initial sorting. Analysis of such variation at the gene expression level could impact single cell functional genomics, cancer, stem-cell research, and drug screening. The on-chip monitoring of individual cells in an isolated environment would prevent cross-contamination, provide high recovery yield, and enable study of biological traits at a single cell level. These advantages of on-chip biological experiments is a significant improvement for a myriad of cell analyses methods, compared to conventional methods, which require bulk samples and provide only averaged information on cell structure and function. We report on a device that integrates a mobile magnetic trap array with microfluidic technology to provide the possibility of separation of immunomagnetically labeled cells and their encapsulation with reagents into picoliter droplets for single cell analysis. The simultaneous reagent delivery and compartmentalization of the cells immediately following sorting are all performed seamlessly within the same chip. These steps offer unique advantages such as the ability to capture cell traits as originated from its native environment, reduced chance of contamination, minimal use of the reagents, and tunable encapsulation characteristics independent of the input flow. Preliminary assay on cell viability demonstrates the potential for the device to be integrated with other up- or downstream on-chip modules to become a powerful single-cell analysis tool.
Collapse
|
38
|
A rapid electrochemical biosensor based on an AC electrokinetics enhanced immuno-reaction. Analyst 2013; 138:4656-62. [DOI: 10.1039/c3an00190c] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
39
|
Abstract
The ability to effectively detect disease-related DNA biomarkers and drug delivery nanoparticles directly in blood is a major challenge for viable diagnostics and therapy monitoring. A DEP method has been developed which allows the rapid isolation, concentration and detection of DNA and nanoparticles directly from human and rat whole blood. Using a microarray device operating at 20 V peak-to-peak and 10 kHz, a wide range of high molecular weight (HMW)-DNA and nanoparticles were concentrated into high-field regions by positive DEP, while the blood cells were concentrated into the low-field regions by negative DEP. A simple fluidic wash removes the blood cells while the DNA and nanoparticles remain concentrated in the DEP high-field regions where they can be detected by fluorescence. HMW-DNA could be detected at 260 ng/mL, which is a detection level suitable for analysis of disease-related cell-free circulating DNA biomarkers. Fluorescent 40 nm nanoparticles could be detected at 9.5 × 10(9) particles/mL, which is a level suitable for monitoring drug delivery nanoparticles. The ability to rapidly isolate and detect DNA biomarkers and nanoparticles from undiluted whole blood will benefit many diagnostic applications by significantly reducing sample preparation time and complexity.
Collapse
|
40
|
Genomic DNA extraction from cells by electroporation on an integrated microfluidic platform. Anal Chem 2012; 84:9632-9. [PMID: 23061629 DOI: 10.1021/ac3026064] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The vast majority of genetic analysis of cells involves chemical lysis for release of DNA molecules. However, chemical reagents required in the lysis interfere with downstream molecular biology and often require removal after the step. Electrical lysis based on irreversible electroporation is a promising technique to prepare samples for genetic analysis due to its purely physical nature, fast speed, and simple operation. However, there has been no experimental confirmation on whether electrical lysis extracts genomic DNA from cells in a reproducible and efficient fashion in comparison to chemical lysis, especially for eukaryotic cells that have most of the DNA enclosed in the nucleus. In this work, we construct an integrated microfluidic chip that physically traps a low number of cells, lyses the cells using electrical pulses rapidly, then purifies and concentrates genomic DNA. We demonstrate that electrical lysis offers high efficiency for DNA extraction from both eukaryotic cells (up to ∼36% for Chinese hamster ovary cells) and bacterial cells (up to ∼45% for Salmonella typhimurium) that is comparable to the widely used chemical lysis. The DNA extraction efficiency has dependence on both the electric parameters and relative amount of beads used for DNA adsorption. We envision that electroporation-based DNA extraction will find use in ultrasensitive assays that benefit from minimal dilution and simple procedures.
Collapse
|
41
|
A micro device for separation of erythrocytes and leukocytes in human blood. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2012; 2006:1024-7. [PMID: 17282361 DOI: 10.1109/iembs.2005.1616592] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
We report a MEMS device for continuous and binary separation of leukocytes (white blood cells, WBCs) and erythrocytes (red blood cells, RBCs) by their sizes. The system consists of PDMS cylindrical pillars inside fluidic chamber on glass slides. A 420 μm lateral separation was achieved for 5 μm and 10 μm beads. The critical particle size for separation was successful predicted by simulation and experimentally determined by calibration with polystyrene beads. The separation function (lateral displacement versus particle size) was also measured experimentally. Diluted whole blood and blood fraction of concentrated leukocytes were tested with the devices with erythrocyte to leukocyte ratio in agreement with blood count results. Experiments with fluorescent labeled leukocytes confirm the separation of leukocytes from erythrocytes and measured the separation efficiency.
Collapse
|
42
|
Shaping acoustic fields as a toolset for microfluidic manipulations in diagnostic technologies. Proc Natl Acad Sci U S A 2012; 109:15162-7. [PMID: 22949692 DOI: 10.1073/pnas.1206055109] [Citation(s) in RCA: 120] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Ultrasonics offers the possibility of developing sophisticated fluid manipulation tools in lab-on-a-chip technologies. Here we demonstrate the ability to shape ultrasonic fields by using phononic lattices, patterned on a disposable chip, to carry out the complex sequence of fluidic manipulations required to detect the rodent malaria parasite Plasmodium berghei in blood. To illustrate the different tools that are available to us, we used acoustic fields to produce the required rotational vortices that mechanically lyse both the red blood cells and the parasitic cells present in a drop of blood. This procedure was followed by the amplification of parasitic genomic sequences using different acoustic fields and frequencies to heat the sample and perform a real-time PCR amplification. The system does not require the use of lytic reagents nor enrichment steps, making it suitable for further integration into lab-on-a-chip point-of-care devices. This acoustic sample preparation and PCR enables us to detect ca. 30 parasites in a microliter-sized blood sample, which is the same order of magnitude in sensitivity as lab-based PCR tests. Unlike other lab-on-a-chip methods, where the sample moves through channels, here we use our ability to shape the acoustic fields in a frequency-dependent manner to provide different analytical functions. The methods also provide a clear route toward the integration of PCR to detect pathogens in a single handheld system.
Collapse
|
43
|
Polymer-Based Microfluidic Devices for Pharmacy, Biology and Tissue Engineering. Polymers (Basel) 2012. [DOI: 10.3390/polym4031349] [Citation(s) in RCA: 103] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
|
44
|
Electric-field-directed self-assembly of active enzyme-nanoparticle structures. J Biomed Biotechnol 2012; 2012:178487. [PMID: 22500078 PMCID: PMC3304025 DOI: 10.1155/2012/178487] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2011] [Accepted: 10/13/2011] [Indexed: 11/18/2022] Open
Abstract
A method is presented for the electric-field-directed self-assembly of higher-order structures composed of alternating layers of biotin nanoparticles and streptavidin-/avidin-conjugated enzymes carried out on a microelectrode array device. Enzymes included in the study were glucose oxidase (GOx), horseradish peroxidase (HRP), and alkaline phosphatase (AP); all of which could be used to form a light-emitting microscale glucose sensor. Directed assembly included fabricating multilayer structures with 200 nm or 40 nm GOx-avidin-biotin nanoparticles, with AP-streptavidin-biotin nanoparticles, and with HRP-streptavidin-biotin nanoparticles. Multilayered structures were also fabricated with alternate layering of HRP-streptavidin-biotin nanoparticles and GOx-avidin-biotin nanoparticles. Results showed that enzymatic activity was retained after the assembly process, indicating that substrates could still diffuse into the structures and that the electric-field-based fabrication process itself did not cause any significant loss of enzyme activity. These methods provide a solution to overcome the cumbersome passive layer-by-layer assembly methods to efficiently fabricate higher-order active biological and chemical hybrid structures that can be useful for creating novel biosensors and drug delivery nanostructures, as well as for diagnostic applications.
Collapse
|
45
|
Dielectrophoresis and shear-enhanced sensitivity and selectivity of DNA hybridization for the rapid discrimination of Candida species. Biosens Bioelectron 2012; 33:36-43. [DOI: 10.1016/j.bios.2011.12.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2011] [Revised: 11/17/2011] [Accepted: 12/04/2011] [Indexed: 10/14/2022]
|
46
|
Isolation of prostate tumor initiating cells (TICs) through their dielectrophoretic signature. LAB ON A CHIP 2012; 12:182-9. [PMID: 22068834 DOI: 10.1039/c1lc20701f] [Citation(s) in RCA: 88] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
In this study, the dielectrophoretic response of prostate tumor initiating cells (TICs) was investigated in a microfluidic system utilizing contactless dielectrophoresis (cDEP). The dielectrophoretic response of prostate TICs was observed to be distinctively different than that for non-TICs, enabling them to be sorted using cDEP. Culturing the sorted TICs generated spheroids, indicating that they were indeed initiating cells. This study presents the first marker-free TIC separation from non-TICs utilizing their electrical fingerprints through dielectrophoresis.
Collapse
|
47
|
Rapid microparticle patterning by enhanced dielectrophoresis effect on a double-layer electrode substrate. Electrophoresis 2011; 32:3371-7. [DOI: 10.1002/elps.201100232] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2011] [Revised: 06/09/2011] [Accepted: 06/24/2011] [Indexed: 11/09/2022]
|
48
|
|
49
|
On-chip collection of particles and cells by AC electroosmotic pumping and dielectrophoresis using asymmetric microelectrodes. BIOMICROFLUIDICS 2011; 5:34113-3411317. [PMID: 22662040 PMCID: PMC3364828 DOI: 10.1063/1.3620419] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2011] [Accepted: 07/12/2011] [Indexed: 05/10/2023]
Abstract
The recent development of microfluidic "lab on a chip" devices requiring sample sizes <100 μL has given rise to the need to concentrate dilute samples and trap analytes, especially for surface-based detection techniques. We demonstrate a particle collection device capable of concentrating micron-sized particles in a predetermined area by combining AC electroosmosis (ACEO) and dielectrophoresis (DEP). The planar asymmetric electrode pattern uses ACEO pumping to induce equal, quadrilateral flow directed towards a stagnant region in the center of the device. A number of system parameters affecting particle collection efficiency were investigated including electrode and gap width, chamber height, applied potential and frequency, and number of repeating electrode pairs and electrode geometry. The robustness of the on-chip collection design was evaluated against varying electrolyte concentrations, particle types, and particle sizes. These devices are amenable to integration with a variety of detection techniques such as optical evanescent waveguide sensing.
Collapse
|
50
|
Design and simulation of a micro-channel for separating the particles with nearly constant dielectrophoretic force in channel space. MOLECULAR SIMULATION 2011. [DOI: 10.1080/08927022.2011.569548] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|