1
|
Kim S, Han G, Hwang D, Won D, Shin Y, Kim C, Kang JM, Park J, Jung H, Park W, Yun J. Design and Usability Evaluations of a 3D-Printed Implantable Drug Delivery Device for Acute Liver Failure in Preclinical Settings. Adv Healthc Mater 2021; 10:e2100497. [PMID: 34160141 DOI: 10.1002/adhm.202100497] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/18/2021] [Indexed: 12/11/2022]
Abstract
Acute liver failure (ALF) requiring liver transplantation is a disease that occurs due to rapid hepatocellular dysfunction. As liver transplantation has various limitations, including donor scarcity, high cost, and immuno-incompatibility, continuous local delivery of biopharmaceuticals to the liver tissue can be a promising ALF treatment option. Here, the in vivo safety and usability of a 3D-printed implantable drug delivery device for effective ALF treatment is evaluated. The implantable reservoir consists of a 3D-printed container and a semipermeable membrane for repeated administrations of drugs, specifically to the liver tissue. The physical stability and function of the 3D-printed reservoir are confirmed by the mechanical properties and in vitro drug release test, respectively. In mice implanted with the reservoir system, mortality, weight changes, clinical signs, hematological and serum biochemical changes, and organ weight changes are not observed, suggesting no foreign body reaction. The usability of the reservoir system is further evaluated using an ALF model of 70% hepatectomized mice treated with N-acetylcysteine through the system, showing cell-specific regeneration and significant liver injury alleviation. Overall, the 3D-printed reservoir system is safe for studying the therapeutic potential of ALF treatment, and it can be used for the delivery of various active pharmaceutical ingredients.
Collapse
Affiliation(s)
- Shin‐Young Kim
- Department of Biotechnology The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
| | - Ginam Han
- Department of Biotechnology The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
- Department of Biomedical‐Chemical Engineering The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
| | - Da‐Bin Hwang
- Department of Biotechnology The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
| | - Dong‐Hoon Won
- Department of Biotechnology The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
| | - Yoo‐Sub Shin
- Department of Biotechnology The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
| | - Changuk Kim
- Department of Biotechnology The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
| | - Jeon Min Kang
- Biomedical Engineering Research Center Asan Institute for Life Sciences Asan Medical Center 88 Olympic‐ro 43‐gil Songpa‐gu Seoul 05505 Republic of Korea
| | - Jung‐Hoon Park
- Biomedical Engineering Research Center Asan Institute for Life Sciences Asan Medical Center 88 Olympic‐ro 43‐gil Songpa‐gu Seoul 05505 Republic of Korea
| | - Hyun‐Do Jung
- Department of Biotechnology The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
- Department of Biomedical‐Chemical Engineering The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
| | - Wooram Park
- Department of Biotechnology The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
- Department of Biomedical‐Chemical Engineering The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
| | - Jun‐Won Yun
- Department of Biotechnology The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
- Department of Medical and Biological Sciences The Catholic University of Korea 43 Jibong‐ro Bucheon‐Si Gyeonggi‐do 14662 Republic of Korea
| |
Collapse
|
2
|
Abstract
Extracorporeal liver support systems (ELSS), encompassing artificial and bioartificial devices, have been used for decades, with the aim of supporting patients with acute liver failure and acute-on chronic liver failure, as a bridge to recovery (acute liver failure only) or liver transplantation, in an era of organ donation shortage. Although biochemical efficacy has been consistently demonstrated by these devices, translation into clinical and survival benefits has been unclear, due to study limitations and lack of reliable prognostic scoring in liver failure. Consequently, extracorporeal devices are not widely accepted as routine therapy in adult liver failure. Recent large multicentre trials using artificial liver systems have not revealed beneficial outcomes associated with albumin dialysis but plasma exchange practices have shown some potential. In paediatric liver failure, data on extracorporeal systems is scarce, comprising few reports on albumin dialysis (namely, Molecular Adsorbent Recirculating System; MARS) and plasma exchange. When extrapolating data from adult studies differences in disease presentation, aetiology, prognosis and the suitability, and safety of such devices in children must be considered. The aim of this review is to critically appraise current practices of extracorporeal liver support systems to help determine efficacy in paediatric liver failure.
Collapse
|
3
|
Hemadsorption with Adult CytoSorb® in a Low Weight Pediatric Case. Case Rep Crit Care 2017; 2017:6987167. [PMID: 28127473 PMCID: PMC5239828 DOI: 10.1155/2017/6987167] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Accepted: 11/28/2016] [Indexed: 12/30/2022] Open
Abstract
Cytokine adsorber (CytoSorb) has been used successfully as adjunctive treatment for adult patients with elevated cytokine levels in the setting with severe sepsis and septic shock and to reduce blood myoglobin, unconjugated bilirubin, and conjugated bilirubin. In this article we present the case of a nine-month-old male infant who was admitted to the NICU due to sepsis after cardiac surgery, Fallot tetralogy, and multisystem organ failure (MSOF) including liver failure and renal failure which was successfully treated by a combination of continuous hemodiafiltration (HDF) and hemadsorption with CytoSorb. HDF was safe and effective from the first day for urea removal, but the patient's bilirubin levels kept increasing gradually, culminating on the 9th day with a maximum value of 54 mg/dL of total bilirubin and 31.67 mg/dL of direct bilirubin when we performed hemadsorption with CytoSorb. Over the 49-hour period of hemadsorption, the total bilirubin value decreased from 54 to 14 mg/dL, and the patient's general status improved considerably accompanied by a rapid drop of aminotransferases. Hemodynamic status has been improved as well and inotropes dropped rapidly. The patient's ventilation settings improved during CytoSorb treatment permitting weaning the patient from mechanical ventilation after five days of hemadsorption. The patient was discharged home after 34 days of hospitalization, in a good general status.
Collapse
|
4
|
Zhou P, Shao L, Zhao L, Lv G, Pan X, Zhang A, Li J, Zhou N, Chen D, Li L. Efficacy of Fluidized Bed Bioartificial Liver in Treating Fulminant Hepatic Failure in Pigs: A Metabolomics Study. Sci Rep 2016; 6:26070. [PMID: 27194381 PMCID: PMC4872127 DOI: 10.1038/srep26070] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Accepted: 04/26/2016] [Indexed: 12/13/2022] Open
Abstract
Bioartificial livers may act as a promising therapy for fulminant hepatic failure (FHF) with better accessibility and less injury compared to orthotopic liver transplantation. This study aims to evaluate the efficacy and safety of a fluidized bed bioartificial liver (FBBAL) and to explore its therapeutic mechanisms based on metabolomics. FHF was induced by D-galactosamine. Eighteen hours later, pigs were treated with an FBBAL containing encapsulated primary porcine hepatocytes (B group), with a sham FBBAL (containing cell-free capsules, S group) or with only intensive care (C group) for 6 h. Serum samples were assayed using ultra-performance liquid chromatography-mass spectrometry. The difference in survival time (51.6 ± 7.9 h vs. 49.3 ± 6.6 h) and serum metabolome was negligible between the S and C groups, whereas FBBAL treatment significantly prolonged survival time (70.4 ± 11.5h, P < 0.01) and perturbed the serum metabolome, resulting in a marked decrease in phosphatidylcholines, lysophosphatidylcholines, sphingomyelinase, and fatty acids and an increase in conjugated bile acids. The FBBAL exhibits some liver functions and may exert its therapeutic effect by altering the serum metabolome of FHF pigs. Moreover, alginate-chitosan capsules have less influence on serum metabolites. Nevertheless, the alterations were not universally beneficial, revealing that much should be done to improve the FBBAL.
Collapse
Affiliation(s)
- Pengcheng Zhou
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
- Xiangya Hospital, Central South University, Changsha, Hunan 410008, P.R. China
| | - Li Shao
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
| | - Lifu Zhao
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
| | - Guoliang Lv
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
| | - Xiaoping Pan
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
| | - Anye Zhang
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
| | - Jianzhou Li
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
| | - Ning Zhou
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
| | - Deying Chen
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
| | - Lanjuan Li
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, P.R. China
| |
Collapse
|
5
|
Stem Cell Therapies for Treatment of Liver Disease. Biomedicines 2016; 4:biomedicines4010002. [PMID: 28536370 PMCID: PMC5344247 DOI: 10.3390/biomedicines4010002] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Revised: 12/30/2015] [Accepted: 12/31/2015] [Indexed: 12/12/2022] Open
Abstract
Cell therapy is an emerging form of treatment for several liver diseases, but is limited by the availability of donor livers. Stem cells hold promise as an alternative to the use of primary hepatocytes. We performed an exhaustive review of the literature, with a focus on the latest studies involving the use of stem cells for the treatment of liver disease. Stem cells can be harvested from a number of sources, or can be generated from somatic cells to create induced pluripotent stem cells (iPSCs). Different cell lines have been used experimentally to support liver function and treat inherited metabolic disorders, acute liver failure, cirrhosis, liver cancer, and small-for-size liver transplantations. Cell-based therapeutics may involve gene therapy, cell transplantation, bioartificial liver devices, or bioengineered organs. Research in this field is still very active. Stem cell therapy may, in the future, be used as a bridge to either liver transplantation or endogenous liver regeneration, but efficient differentiation and production protocols must be developed and safety must be demonstrated before it can be applied to clinical practice.
Collapse
|
6
|
Extracorporeal liver assist device to exchange albumin and remove endotoxin in acute liver failure: Results of a pivotal pre-clinical study. J Hepatol 2015; 63:634-42. [PMID: 25937432 PMCID: PMC4541472 DOI: 10.1016/j.jhep.2015.04.020] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2015] [Revised: 04/04/2015] [Accepted: 04/22/2015] [Indexed: 02/08/2023]
Abstract
BACKGROUND & AIMS In acute liver failure, severity of liver injury and clinical progression of disease are in part consequent upon activation of the innate immune system. Endotoxaemia contributes to innate immune system activation and the detoxifying function of albumin, critical to recovery from liver injury, is irreversibly destroyed in acute liver failure. University College London-Liver Dialysis Device is a novel artificial extracorporeal liver assist device, which is used with albumin infusion, to achieve removal and replacement of dysfunctional albumin and reduction in endotoxaemia. We aimed to test the effect of this device on survival in a pig model of acetaminophen-induced acute liver failure. METHODS Pigs were randomised to three groups: Acetaminophen plus University College London-Liver Dialysis Device (n=9); Acetaminophen plus Control Device (n=7); and Control plus Control Device (n=4). Device treatment was initiated two h after onset of irreversible acute liver failure. RESULTS The Liver Dialysis Device resulted in 67% reduced risk of death in acetaminophen-induced acute liver failure compared to Control Device (hazard ratio=0.33, p=0.0439). This was associated with 27% decrease in circulating irreversibly oxidised human non-mercaptalbumin-2 throughout treatment (p=0.046); 54% reduction in overall severity of endotoxaemia (p=0.024); delay in development of vasoplegia and acute lung injury; and delay in systemic activation of the TLR4 signalling pathway. Liver Dialysis Device-associated adverse clinical effects were not seen. CONCLUSIONS The survival benefit and lack of adverse effects would support clinical trials of University College London-Liver Dialysis Device in acute liver failure patients.
Collapse
|
7
|
Liu H, Yu Y, Glorioso J, Mao S, Rodysil B, Amiot BP, Rinaldo P, Nyberg SL. Cold Storage of Rat Hepatocyte Spheroids. Cell Transplant 2014; 23:819-30. [DOI: 10.3727/096368913x664847] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Cell-based therapies for liver disease rely on a high-quality supply of hepatocytes and a means for storage during transportation from site of isolation to site of usage. Unfortunately, frozen cryopreservation is associated with unacceptable loss of hepatocyte viability after thawing. The purpose of this study was to optimize conditions for cold storage of rat hepatocyte spheroids without freezing. Rat hepatocytes were isolated by a two-step perfusion method; hepatocyte spheroids were formed during 48 h of rocked culture in serum-free medium (SFM). Spheroids were then maintained in rocked culture at 37°C (control condition) or cold stored at 4°C for 24 or 48 h in six different cold storage solutions: SFM alone; SFM + 1 mM deferoxamine (Def); SFM + 1 μM cyclosporin A (CsA); SFM + 1 mM Def + 1 μM CsA, University of Wisconsin (UW) solution alone, UW + 1 mM Def. Performance metrics after cold storage included viability, gene expression, albumin production, and functional activity of cytochrome P450 enzymes and urea cycle proteins. We observed that cold-induced injury was reduced significantly by the addition of the iron chelator (Def) to both SFM and UW solution. Performance metrics (ammonia detoxification, albumin production) of rat hepatocyte spheroids stored in SFM + Def for 24 h were significantly increased from SFM alone and approached those in control conditions, while performance metrics after cold storage in SFM alone or cold storage for 48 h were both significantly reduced. A serum-free medium supplemented with Def allowed hepatocyte spheroids to tolerate 24 h of cold storage with less than 10% loss in viability and functionality. Further research is warranted to optimize a solution for extended cold storage of hepatocyte spheroids.
Collapse
Affiliation(s)
- Hongling Liu
- Division of Experimental Surgery, Mayo Clinic College of Medicine, Rochester, MN, USA
- Liver Failure Diagnosis and Treatment Center, 302 Military Hospital, Beijing, P.R. China
| | - Yue Yu
- Division of Experimental Surgery, Mayo Clinic College of Medicine, Rochester, MN, USA
- Liver Transplantation Center, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province, P.R. China
| | - Jaime Glorioso
- Division of Experimental Surgery, Mayo Clinic College of Medicine, Rochester, MN, USA
| | - Shennen Mao
- Division of Experimental Surgery, Mayo Clinic College of Medicine, Rochester, MN, USA
| | - Brian Rodysil
- Division of Experimental Surgery, Mayo Clinic College of Medicine, Rochester, MN, USA
| | | | - Piero Rinaldo
- Department of Laboratory Medicine and Pathology, Mayo Clinic College of Medicine, Rochester, MN, USA
| | - Scott L. Nyberg
- Division of Experimental Surgery, Mayo Clinic College of Medicine, Rochester, MN, USA
| |
Collapse
|
8
|
Jiang HL, Kim YK, Cho KH, Jang YC, Choi YJ, Chung JH, Cho CS. Roles of spheroid formation of hepatocytes in liver tissue engineering. Int J Stem Cells 2014; 3:69-73. [PMID: 24855543 DOI: 10.15283/ijsc.2010.3.2.69] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/18/2010] [Indexed: 01/15/2023] Open
Abstract
The liver plays an important role in a broad spectrum of physiological functions and detoxifies endogenous and exogenous substances. The liver failure is associated with a high risk of mortality because it is one of important organs in our body. Various bioartificial liver (BAL) systems have been used for clinical trials as a bridge for liver transplantations in patients with liver failure. Long term and stable liver-specific functions of hepatocytes in the development of BAL support systems should be considered. Spheroid formation of hepatocytes enhances liver-specific functions. In this review, hepatocyte spheroid formation methods such as galactose density, topology of extracellular matrix, micro-molding technique, hanging-drop culture, non-adhesive surface, positive charged surface, spinner culture, rocked technique, medium component, external forces, coculture system and polymeric nanospheres are explained for enhancing liver-specific functions.
Collapse
Affiliation(s)
- Hu-Lin Jiang
- College of Veterinary Medicine, Seoul National University, Seoul, Korea
| | - You-Kyoung Kim
- Department of Agricultural Biotechnology and Research Institute for Agriculture and Life Sciences, Seoul National University, Seoul, Korea
| | - Ki-Hyun Cho
- Department of Plastic and Reconstructive Surgery, Hangang Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| | - Young-Chul Jang
- Department of Plastic and Reconstructive Surgery, Hangang Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| | - Yun-Jaie Choi
- Department of Agricultural Biotechnology and Research Institute for Agriculture and Life Sciences, Seoul National University, Seoul, Korea
| | - Jong-Hoon Chung
- Department of Biosystem Engineering and Biomaterial Sciences, Seoul National University, Seoul, Korea
| | - Chong-Su Cho
- Department of Agricultural Biotechnology and Research Institute for Agriculture and Life Sciences, Seoul National University, Seoul, Korea
| |
Collapse
|
9
|
Abstract
Acute liver failure occurs abruptly with rapid progression. Traditional medical treatment and simple non-bioartificial liver support system cannot reverse the prognosis of acute liver failure (ALF), and liver transplantation is the only effective treatment. However, donor liver shortage, the need of a life-long immunosuppressive therapy as well as complex postoperative complications make ALF patients facing a variety of challenges in the perioperative period of liver transplantation, which are directly related to the success rate of surgery and the mortality. This article aims to discuss perioperative difficulties and preventive measures in liver transplantation for ALF by exploring how to extend the lives of patients before liver transplantation and how to deal with postoperative complications.
Collapse
|
10
|
Zheng Z, Li X, Li Z, Ma X. Artificial and bioartificial liver support systems for acute and acute-on-chronic hepatic failure: A meta-analysis and meta-regression. Exp Ther Med 2013; 6:929-936. [PMID: 24137292 PMCID: PMC3797301 DOI: 10.3892/etm.2013.1241] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2013] [Accepted: 07/03/2013] [Indexed: 02/07/2023] Open
Abstract
Artificial and bioartificial liver support systems (LSSs) appear to be safe and effective in the treatment of acute and acute-on-chronic hepatic failure (AHF and AOCHF); however, individually published studies and previous meta-analyses have revealed inconclusive results. The aim of the present meta-analysis was to derive a more precise estimation of the benefits and disadvantages of artificial and bioartificial LSSs for patients with AHF and AOCHF. A literature search was conducted in the PubMed, Embase, Web of Science and Chinese Biomedical (CBM) databases for publications prior to March 1, 2013. Crude relative risks (RRs) or standardized mean differences (SMDs) with 95% confidence intervals (95% CI) were calculated using either the fixed effects or random effects models. Nineteen randomized controlled trials (RCTs) were included, which comprised a total of 566 patients with AHF and 371 patients with AOCHF. The meta-analysis showed that artificial LSS therapy significantly reduced mortality in patients with AOCHF; however, it had no apparent effect on total mortality in patients with AHF. The results also indicated that the use of bioartificial LSSs was correlated with decreased mortality in patients with AHF. A significant reduction in the bridging to liver transplantation was observed in patients with AOCHF following artificial LSS therapy; however, similar results were not observed in patients with AHF. Patients with AHF and those with AOCHF showed significant reductions in total bilirubin levels following artificial LSS therapy. There were no significantly increased risks of hepatic encephalopathy or bleeding in either the patients with AHF or AOCHF following artificial or bioartificial LSS therapies. Univariate and multivariate meta-regression analyses confirmed that none of the factors explained the heterogeneity. The present meta-analysis indicated that artificial LSSs reduce mortality in patients with AOCHF, while the use of bioartificial LSSs was correlated with reduced mortality in patients with AHF.
Collapse
Affiliation(s)
- Zhen Zheng
- Department of Intensive Care Unit, The First Hospital, China Medical University, Heping, Shenyang, Liaoning 110001, P.R. China
| | | | | | | |
Collapse
|
11
|
Gu J, Shi X, Ren H, Xu Q, Wang J, Xiao J, Ding Y. Systematic review: extracorporeal bio-artificial liver-support system for liver failure. Hepatol Int 2012; 6:670-683. [PMID: 26201519 DOI: 10.1007/s12072-012-9352-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2011] [Accepted: 02/21/2012] [Indexed: 01/14/2023]
Abstract
BACKGROUND Orthotopic liver transplantation (OLT) is the only effective long-term treatment for liver failure by now. However, it is not yet a perfect choice due to donor-organ shortage and the need of a lifelong immunosuppressive therapy. Therefore, it is necessary to find a new approach to fighting the disease. Several published clinical trials have reported the therapeutic effect of bio-artificial liver (BAL) for liver failure. OBJECTIVE To overview and evaluate the current clinical application and outcomes of extracorporeal BAL support system during the past 15 years. METHODS Relevant studies were retrieved from PubMed and Cochrane Library databases. Independent assessments and the final consensus decision were performed by three independent reviewers. Acceptable study designs included randomized controlled trials, controlled clinical trials, and case reports. A total of 31 studies were tabulated and critically appraised in terms of characteristics, methods, and outcomes. RESULTS There was a trend of falling into the normal ranges with the clinical and biochemical parameters after the BAL treatment. The neurological status of most patients was improved or stabilized during BAL treatment as well. No significant effect on survival could be seen after the BAL treatment. CONCLUSIONS Although BAL system proved to be a success in some clinical cases reported, it still needs to be improved greatly.
Collapse
Affiliation(s)
- Jinyang Gu
- Department of Hepatobiliary Surgery, Affiliated Drum Tower Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing, China
- Jiangsu Province's Key Medical Center for Hepatobiliary Disease, Nanjing, China
| | - Xiaolei Shi
- Department of Hepatobiliary Surgery, Affiliated Drum Tower Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing, China
- Jiangsu Province's Key Medical Center for Hepatobiliary Disease, Nanjing, China
| | - Haozhen Ren
- Department of Hepatobiliary Surgery, Affiliated Drum Tower Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing, China
| | - Qingxiang Xu
- Department of Hepatobiliary Surgery, Affiliated Drum Tower Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing, China
- Jiangsu Province's Key Medical Center for Hepatobiliary Disease, Nanjing, China
| | - Jun Wang
- Department of Hepatobiliary Surgery, Drum Tower Clinical Medical College of Nanjing Medical University, Nanjing, China
| | - Jiangqiang Xiao
- Department of Hepatobiliary Surgery, Affiliated Drum Tower Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing, China
| | - Yitao Ding
- Department of Hepatobiliary Surgery, Affiliated Drum Tower Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing, China.
- Jiangsu Province's Key Medical Center for Hepatobiliary Disease, Nanjing, China.
| |
Collapse
|
12
|
Bao J, Fisher JE, Lillegard JB, Wang W, Amiot B, Yu Y, Dietz AB, Nahmias Y, Nyberg SL. Serum-free medium and mesenchymal stromal cells enhance functionality and stabilize integrity of rat hepatocyte spheroids. Cell Transplant 2012; 22:299-308. [PMID: 23006214 DOI: 10.3727/096368912x656054] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Long-term culture of hepatocyte spheroids with high ammonia clearance is valuable for therapeutic applications, especially the bioartificial liver. However, the optimal conditions are not well studied. We hypothesized that liver urea cycle enzymes can be induced by high protein diet and maintain on a higher expression level in rat hepatocyte spheroids by serum-free medium (SFM) culture and coculture with mesenchymal stromal cells (MSCs). Rats were feed normal protein diet (NPD) or high protein diet (HPD) for 7 days before liver digestion and isolation of hepatocytes. Hepatocyte spheroids were formed and maintained in a rocked suspension culture with or without MSCs in SFM or 10% serum-containing medium (SCM). Spheroid viability, kinetics of spheroid formation, hepatic functions, gene expression, and biochemical activities of rat hepatocyte spheroids were tested over 14 days of culture. We observed that urea cycle enzymes of hepatocyte spheroids can be induced by high protein diet. SFM and MSCs enhanced ammonia clearance and ureagenesis and stabilized integrity of hepatocyte spheroids compared to control conditions over 14 days. Hepatocytes from high protein diet-fed rats formed spheroids and maintained a high level of ammonia detoxification for over 14 days in a novel SFM. Hepatic functionality and spheroid integrity were further stabilized by coculture of hepatocytes with MSCs in the spheroid microenvironment. These findings have direct application to development of the spheroid reservoir bioartificial liver.
Collapse
Affiliation(s)
- Ji Bao
- Department of Pathology, West China Hospital, Chengdu, Sichuan, People's Republic of China
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Giri S, Acikgöz A, Pathak P, Gutschker S, Kürsten A, Nieber K, Bader A. Three dimensional cultures of rat liver cells using a natural self-assembling nanoscaffold in a clinically relevant bioreactor for bioartificial liver construction. J Cell Physiol 2011; 227:313-27. [PMID: 21437901 DOI: 10.1002/jcp.22738] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Till date, no bioartificial liver (BAL) procedure has obtained FDA approval or widespread clinical acceptance, mainly because of multifactorial limitations such as the use of microscale or undefined biomaterials, indirect and lower oxygenation levels in liver cells, short-term undesirable functions, and a lack of 3D interaction of growth factor/cytokine signaling in liver cells. To overcome preclinical limitations, primary rat liver cells were cultured on a naturally self-assembling peptide nanoscaffold (SAPN) in a clinically relevant bioreactor for up to 35 days, under 3D interaction with suitable growth factors and cytokine signaling agents, alone or combination (e.g., Group I: EPO, Group II: Activin A, Group III: IL-6, Group IV: BMP-4, Group V: BMP4 + EPO, Group VI: EPO + IL-6, Group VII: BMP4 + IL-6, Group VIII: Activin A + EPO, Group IX: IL-6 + Activin A, Group X: Activin A + BMP4, Group XI: EPO + Activin A + BMP-4 + IL-6 + HGF, and Group XII: Control). Major liver specific functions such as albumin secretion, urea metabolism, ammonia detoxification, phase contrast microscopy, immunofluorescence of liver specific markers (Albumin and CYP3A1), mitochondrial status, glutamic oxaloacetic transaminase (GOT) activity, glutamic pyruvic transaminase (GPT) activity, and cell membrane stability by the lactate dehydrogenase (LDH) test were also examined and compared with the control over time. In addition, we examined the drug biotransformation potential of a diazepam drug in a two-compartment model (cell matrix phase and supernatant), which is clinically important. This present study demonstrates an optimized 3D signaling/scaffolding in a preclinical BAL model, as well as preclinical drug screening for better drug development.
Collapse
Affiliation(s)
- Shibashish Giri
- Department of Cell Techniques and Applied Stem Cell Biology, Centre for Biotechnology and Biomedicine, University of Leipzig, Leipzig, Germany.
| | | | | | | | | | | | | |
Collapse
|
14
|
Giri S, Bader A. Improved preclinical safety assessment using micro-BAL devices: the potential impact on human discovery and drug attrition. Drug Discov Today 2011; 16:382-97. [PMID: 21354326 DOI: 10.1016/j.drudis.2011.02.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2010] [Revised: 01/11/2011] [Accepted: 02/21/2011] [Indexed: 02/07/2023]
Abstract
Hepatotoxicity is often unpredictable in the early phase of drug discovery and leads to drug attrition in preclinical and clinical development. Here, we discuss the conventional preclinical liver models that do not mimic in vivo livers. We focus on key components such as new sources of hepatocyte-derived human stem cells, enhanced direct oxygenation, defined biocompatibility nanoscaffolds, organotypical cellular models, dynamic culture, and metabolite status inside and outside the cell for effective configuration for the development of a bioartificial liver (BAL) device to mimic the in vivo liver microenvironment. The potential for development of BAL devices could open up new avenues in: (i) hepatotoxicity assessment for selecting drug candidates during preclinical screening; and (ii) therapeutic approaches for liver cell therapy at the clinical stage.
Collapse
Affiliation(s)
- Shibashish Giri
- Centre for Biotechnology and Biomedicine, Department of Cell Techniques and Applied Stem Cell Biology, University of Leipzig, Deutscher Platz 5, D-04103 Leipzig, Germany.
| | | |
Collapse
|
15
|
Preparation of polyamine-functionalized copper specific adsorbents for selective adsorption of copper. Colloids Surf B Biointerfaces 2010; 78:222-8. [DOI: 10.1016/j.colsurfb.2010.03.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2009] [Revised: 03/10/2010] [Accepted: 03/10/2010] [Indexed: 02/02/2023]
|
16
|
Lee KH, Shin SJ, Kim CB, Kim JK, Cho YW, Chung BG, Lee SH. Microfluidic synthesis of pure chitosan microfibers for bio-artificial liver chip. LAB ON A CHIP 2010; 10:1328-34. [PMID: 20445889 DOI: 10.1039/b924987g] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We developed microfluidic-based pure chitosan microfibers (approximately 1 meter long, 70-150 microm diameter) for liver tissue engineering applications. Despite the potential of the chitosan for creating bio-artificial liver chips, its major limitation is the inability to fabricate pure chitosan-based microstructures with controlled shapes because of the mechanical weakness of the pure chitosan. Previous studies have shown that chitosan micro/nanofibers can be fabricated by using chemicals and electrospinning techniques. However, there is no paper regarding pure chitosan-based microfibers in a microfluidic device. This paper suggests a unique method to fabricate pure chitosan microfibers without any chemical additive. We also analyzed the chemical, mechanical, and diffusion properties of pure chitosan microfibers. Attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectrometry and electron spectroscopy for chemical analysis (ESCA) were used to analyze the chemical composition of the synthesized chitosan microfibers. We measured the mechanical axial-force and diffusion coefficient in pure chitosan-based microfibers using fluorescence recovery after photobleaching (FRAP) techniques. Furthermore, to evaluate the capability of the microfibers for liver tissue formation, hepatoma HepG2 cells were seeded onto the chitosan microfibers. The functionality of these hepatic cells cultured on chitosan microfibers was analyzed by measuring albumin secretion and urea synthesis. Therefore, this pure chitosan-based microfiber chip could be a potentially useful method for liver tissue engineering applications.
Collapse
Affiliation(s)
- Kwang Ho Lee
- Department of Biomedical Engineering, College of Health Science, Korea University, Seoul, Korea
| | | | | | | | | | | | | |
Collapse
|
17
|
Wurm M, Woess C, Libiseller K, Beer B, Pavlic M. Challenging Small Human Hepatocytes with Opiates: Further Characterization of a Novel Prototype Bioartificial Liver. Tissue Eng Part A 2010; 16:807-13. [DOI: 10.1089/ten.tea.2009.0420] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Affiliation(s)
- Martin Wurm
- Department of General and Transplant Surgery, Medical University of Innsbruck, Innsbruck, Austria
| | - Claudia Woess
- Institute of Legal Medicine, Innsbruck Medical University, Innsbruck, Austria
| | - Kathrin Libiseller
- Institute of Legal Medicine, Innsbruck Medical University, Innsbruck, Austria
| | - Beate Beer
- Institute of Legal Medicine, Innsbruck Medical University, Innsbruck, Austria
| | - Marion Pavlic
- Institute of Legal Medicine, Innsbruck Medical University, Innsbruck, Austria
| |
Collapse
|
18
|
Chen G, Palmer AF. Mixtures of hemoglobin-based oxygen carriers and perfluorocarbons exhibit a synergistic effect in oxygenating hepatic hollow fiber bioreactors. Biotechnol Bioeng 2010; 105:534-42. [DOI: 10.1002/bit.22571] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
19
|
Yagi H, Parekkadan B, Suganuma K, Soto-Gutierrez A, Tompkins RG, Tilles AW, Yarmush ML. Long-term superior performance of a stem cell/hepatocyte device for the treatment of acute liver failure. Tissue Eng Part A 2010; 15:3377-88. [PMID: 19397469 DOI: 10.1089/ten.tea.2008.0681] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Cell-based technologies to support/restore organ function represent one of the most promising avenues in the treatment of acute liver failure (ALF). Recently, mesenchymal stem cells (MSCs) have been reported as a new therapeutic for inflammatory conditions. Here, we demonstrate the efficacy of MSCs, when cocultured with hepatocytes, to provide combination hepatic and antiinflammatory therapy in the setting of ALF. MSCs were shown to have multiple beneficial effects in vitro that were relevant in a therapeutic context, including (1) hepatocellular functional support, (2) secretion of molecules that inhibit hepatocyte apoptosis, and (3) modulation of an acute phase response by hepatocytes cultured in ALF-induced serum. In addition, we show that the MSC secretome is dynamically changed in response to serum exposure from ALF rats. We then conducted a therapeutic trial of liver assist devices (LADs). LADs containing cocultures of MSCs and hepatocytes provided a greater survival benefit compared to other coculture and monocellular control LADs. Treatment with MSC-hepatocyte devices was associated with specific improvements in hepatic functional and histological parameters as well as decreasing inflammatory serum cytokine levels, validating a combined therapeutic effect. Moreover, MSC coculture reduced the overall cell mass of the device by an order of magnitude. These findings demonstrate the importance of nonparenchymal cells in the cellular composition of LADs, and strongly support the integration of MSCs into hepatocyte-coculture-based LADs as a potential destination therapy for ALF.
Collapse
Affiliation(s)
- Hiroshi Yagi
- Center for Engineering in Medicine and Surgical Services, Massachusetts General Hospital, Shriners Hospitals for Children and Harvard Medical School, Boston, Massachusetts 02114, USA
| | | | | | | | | | | | | |
Collapse
|
20
|
Nedredal GI, Amiot BP, Nyberg P, Luebke-Wheeler J, Lillegard JB, McKenzie TJ, Nyberg SL. Optimization of mass transfer for toxin removal and immunoprotection of hepatocytes in a bioartificial liver. Biotechnol Bioeng 2009; 104:995-1003. [PMID: 19557829 DOI: 10.1002/bit.22450] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
This study was designed to determine optimal operating conditions of a bioartificial liver (BAL) based on mass transfer of representative hepatotoxins and mediators of immune damage. A microprocessor-controlled BAL was used to study mass transfer between patient and cell compartments separated by a hollow fiber membrane. Membrane permeability (70, 150, or 400 kDa molecular weight cut-off-MWCO), membrane convection (high: 50 mL/min; medium: 25 mL/min; low: 10 mL/min; diffusion: 0 mL/min), and albumin concentration in the cell compartment (0.5 or 5 g%) were considered for a total of 24 test conditions. Initially, the patient compartment contained pig plasma supplemented with ammonia (0.017 kDa), unconjugated bilirubin (0.585 kDa), conjugated bilirubin (0.760 kDa), TNF-alpha (17 kDa), pig albumin (67 kDa), pig IgG (147 kDa), and pig IgM (900 kDa). Mass transfer of each substance was determined by its rate of appearance in the cell compartment. Membrane fouling was assessed by dextran polymer technique. Of the three tested variables (membrane pore size, convection, and albumin concentration), membrane permeability had the greatest impact on mass transfer (P < 0.001). Mass transfer of all toxins was greatest under high convection with a 400 kDa membrane. Transfer of IgG and IgM was insignificant under all conditions. Bilirubin transfer was increased under high albumin conditions (P = 0.055). Fouling of membranes ranged from 7% (400 kDa), 24% (150 kDa) to 62% (70 kDa) during a 2-h test interval. In conclusion, optimal toxin removal was achieved under high convection with a 400-kDa membrane, a condition which should provide adequate immunoprotection of hepatocytes in the BAL.
Collapse
Affiliation(s)
- Geir I Nedredal
- Division of Transplantation Surgery, Department of Surgery, Mayo Clinic, Rochester, Minnesota 55905, USA
| | | | | | | | | | | | | |
Collapse
|
21
|
Yokoi T, Oda S, Shiga H, Matsuda KI, Sadahiro T, Nakamura M, Hirasawa H. Efficacy of high-flow dialysate continuous hemodiafiltration in the treatment of fulminant hepatic failure. Transfus Apher Sci 2009; 40:61-70. [DOI: 10.1016/j.transci.2008.11.006] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
22
|
Abstract
Acute liver failure (ALF) is a widespread problem with typically unfavorable prognosis. With the implementation of a liver support device in the clinical setting for treatment of patients with ALF, anticipated improvements include prolonging time available for spontaneous recovery and bridging to liver transplantation. Liver support could also serve to prevent systemic manifestations of ALF such as renal failure, pulmonary edema, systemic inflammatory response syndrome and cerebral edema evolving to brain death. Both non-cell based and cell based (bio-artificial) systems have been used in clinical trials. Systems with closed or open loop organization present different advantages and disadvantages; systems also differ in the membrane pore size for filtrate/dialysate exchange. Further optimization of liver assist devices is still required; when a system has proved to be successful in treating the debilitating results of ALF, the benefits will be enormous to liver failure patients.
Collapse
Affiliation(s)
- Colleen M Brophy
- Division of Transplantation Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | | |
Collapse
|
23
|
Abstract
Acute liver failure (ALF) is a rare but challenging clinical syndrome with multiple causes; a specific etiology cannot be identified in 15% of adult and 50% of pediatric cases. The course of ALF is variable and the mortality rate is high. Liver transplantation is the only therapy of proven benefit, but the rapidity of progression and the variable course of ALF limit its use. Currently in the United States, spontaneous survival occurs in approximately 45%, liver transplantation in 25%, and death without transplantation in 30% of adults with ALF. Higher rates of spontaneous recovery (56%) and transplantation (31%) with lower rates of death (13%) occur in children. The outcome of ALF varies by etiology, favorable prognoses being found with acetaminophen overdose, hepatitis A, and ischemia (approximately 60% spontaneous survival), and poor prognoses with drug-induced ALF, hepatitis B, and indeterminate cases (approximately 25% spontaneous survival). Excellent intensive care is critical in management of patients with ALF. Nonspecific therapies are of unproven benefit. Future possible therapeutic approaches include N-acetylcysteine, hypothermia, liver assist devices, and hepatocyte transplantation. Advances in stem cell research may allow provision of cells for bioartificial liver support. ALF presents many challenging opportunities in both clinical and basic research.
Collapse
Affiliation(s)
- William M Lee
- Division of Digestive and Liver Diseases, University of Texas Southwestern Medical School, Dallas, TX 75390-8887, USA.
| | | | | | | | | |
Collapse
|
24
|
Zhang SC, Wang YJ, Chen Z, Liu T, Liu J. Preliminary study of the viability of neonatal mini-porcine hepatocytes in extracorporeal circulation. Shijie Huaren Xiaohua Zazhi 2007; 15:3787-3792. [DOI: 10.11569/wcjd.v15.i36.3787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
AIM: To observe the viability of neonatal mini-porcine hepatocytes in extracorporeal circulation.
METHODS: A hepatocyte circulation system was constructed with Cello artificial capillary culture equipment and freshly isolated hepatocyte suspensions were circulated at 50 mL/min in vitro. The viability, function and morphological characteristics of hepatocytes were examined within 8 hours.
RESULTS: After 4 hours circulation, the viability and adherence ratio of hepatocytes were 76.1% ± 1.4% and 62.8% ± 1.8%, respectively, and the ratio of amino clearance was about 62.7% ± 14.6% of that in the control group. However, with time, many fragments of hepatocytes were observed in the circulating suspensions, as well as a significant increase in lactate dehydrogenase and aspartate aminotransferase (P < 0.01). The cell viability and adherence ratio, synthesis of urea and albumin, and the clearance rate of ammonia also decreased significantly (P < 0.05).
CONCLUSION: Porcine hepatocyte suspensions can be applied to BAL system in a circulation condition in order to strengthen the mass exchange. However, these cells need to be changed regularly to maintain cellular viability and the supporting effects of BAL.
Collapse
|
25
|
Wurm M, Lubei V, Caronna M, Hermann M, Margreiter R, Hengster P. Development of a Novel Perfused Rotary Cell Culture System. ACTA ACUST UNITED AC 2007; 13:2761-8. [PMID: 17764400 DOI: 10.1089/ten.2007.0082] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A rotary cell culture system has been established. System quality was determined by observing the stability of the basic parameters of temperature, gas exchange, and pH, and mass transfer (time to equimolarity) between the medium circuit and the 2 cell-containing chambers was investigated. Mass transfer time for urea and several ions was approximately 30 min for the high-fiber-density chamber (HFC) and 50 min for the low-fiber-density chamber (LFC). Exchange of albumin was delayed in both chambers, highlighting the dependence of mass transfer on area of exchange and molecule size. Finally, the ability for cell growth and maintenance was tested. Densities of up to 1.2 x 10(7) immortalized cells per mL at a viability of up to 85% were obtained after 1 week of continuous, non-interfering culture of immortalized cells in the HFC. Human pancreatic islets were also cultivated in the LFC. Confocal analysis using fluorescent dyes showed that the 3-dimensional islet structure was maintained for 1 week. Promising results were obtained, which will further our ongoing efforts toward establishing a mobile cell culture system.
Collapse
Affiliation(s)
- Martin Wurm
- BAL Project, Division of General and Transplant Surgery, Innsbruck Medical University, Innsbruck, Austria.
| | | | | | | | | | | |
Collapse
|
26
|
Erickson TB, Thompson TM, Lu JJ. The approach to the patient with an unknown overdose. Emerg Med Clin North Am 2007; 25:249-81; abstract vii. [PMID: 17482020 DOI: 10.1016/j.emc.2007.02.004] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Toxic overdose can present with various clinical signs and symptoms. These may be the only clues to diagnosis when the cause of toxicity is unknown at the time of initial assessment. The prognosis and clinical course of recovery of a patient poisoned by a specific agent depends largely on the quality of care delivered within the first few hours in the emergency setting. Usually the drug or toxin can be quickly identified by a careful history, a directed physical examination, and commonly available laboratory tests. Once the patient has been stabilized, the physician must consider how to minimize the bioavailability of toxin not yet absorbed, which antidotes (if any) to administer, and if other measures to enhance elimination are necessary.
Collapse
Affiliation(s)
- Timothy B Erickson
- Department of Emergency Medicine, Division of Clinical Toxicology, University of Illinois at Chicago, Toxikon Consortium, Chicago, IL 60612, USA.
| | | | | |
Collapse
|
27
|
Pavlic M, Libiseller K, Hermann M, Hengster P, Margreiter R, Wurm M. Small human hepatocytes in rotary culture for treatment of alcohol addicts? A pilot study. Alcohol Clin Exp Res 2007; 31:729-36. [PMID: 17378920 DOI: 10.1111/j.1530-0277.2007.00357.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Current approaches to support alcohol addict and/or benzodiazepine-treated patients with liver failure include culturing human cells to take over basic metabolic functions for a certain time. METHODS Small human hepatocytes (SH) were grown in a rotary cell culture system, and their potential to metabolize alcohol and the benzodiazepines oxazepam and diazepam was evaluated. Control experiments were performed with SV40-immortalized HEP cells and cell respective drug-free media. RESULTS Our results show that SH in rotary culture are able to metabolize ethanol in reasonable amounts compared with evaporation controls (p<0.01). Moreover, SH are also able to metabolize oxazepam and diazepam which proves their ability to perform conjugation and the presence of functional cytochrome P450 enzymes. Basic metabolic activities such as glucose consumption, albumin and urea production are not significantly influenced by the drugs used, which is a precondition for clinical use of these cells. Significantly increased lactate dehydrogenase release indicates enhanced cell death in cultures of SH incubated with either ethanol (p<0.05) or diazepam (p<0.005), but stable viability at or above 90% suggests that cell proliferation is able to keep up with drug-induced cell death. CONCLUSION Our preliminary study provides evidence that SH are basically suited to support alcohol-abusing and/or benzodiazepine-treated patients undergoing liver failure.
Collapse
Affiliation(s)
- Marion Pavlic
- Institute of Legal Medicine, Innsbruck Medical University, Innsbruck, Austria.
| | | | | | | | | | | |
Collapse
|
28
|
Wu YM, Kumaran V, Benten D, Gupta S. Potential of bioengineering processes for therapeutic repopulation of the liver with cells. BIOTECHNOL BIOPROC E 2007. [DOI: 10.1007/bf02931796] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
29
|
Schwartlander R, Schmid J, Brandenburg B, Katenz E, Vondran FWR, Pless G, Cheng X, Pascher A, Neuhaus P, Sauer IM. Continuously Microscopically Observed and Process-Controlled Cell Culture Within the SlideReactor: Proof of a New Concept for Cell Characterization. ACTA ACUST UNITED AC 2007; 13:187-96. [PMID: 17518592 DOI: 10.1089/ten.2006.0071] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Certain cell types, especially primary human cells, favor a well-defined culture environment offering continuous supply of nutrients and oxygen and waste product removal. Several bioreactors based on special matrices or hollow fibers have been developed that provide such conditions. However, characterization of matrix re-organization or growth of tissue within these systems is possible only after culture termination. Evaluation of the influence of certain medium additives or culture conditions (e.g., temperature, oxygenation) on cell viability, expansion, and differentiation within these systems remains a challenging task. The SlideReactor, a miniaturized hollow fiber-based bioreactor, was developed to enable the observation of cells during culture. An operation concept offering predefined conditions for various cell types has been designed. For proof of concept, primary human cells (hepatocytes, fibroblasts, keratinocytes) and cell lines (HepG2, HuH7, C3A, WiDr, SkHep1) were cultured and observed. A series of experiments (n=40) showed the feasibility of the set-up; determination of process parameters and continuous observation is possible. The SlideReactor may serve as a simple and cost-efficient tool for cell characterization and optimization of cell-culture conditions.
Collapse
Affiliation(s)
- Ruth Schwartlander
- Department of General, Visceral, and Transplantation Surgery, Charité-Campus Virchow-Klinikum, Universitätsmedizin Berlin, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Abstract
The incidence of hyperbilirubinemia is high clinically, which is difficult to cure by medication, surgery or interventional therapies. Non-bioartificial liver is the main alternative in the blood purification for hyperbilirubinemia, which includes plasma exchange, hemoperfusion, hemodialysis, molecular adsorbent recycling system and so on. The research results and clinical experiences in China show that these methods are effective in lowering high levels of bilirubin with fewer side effects. The hyperbilirubinemias of different causes, with different complications or accompanying different diseases can be treated by different methods. Bioartificial liver, hybrid artificial liver support system and adsorbent membrane material have also been studied and their development in reducing hyperbilirubinemias has been achieved. This article gives a brief overview on the actuality and research improvement in blood purification for hyperbilirubinemia in China.
Collapse
Affiliation(s)
- Zhi-Jun Duan
- Department of Gastroenterology, First Affiliated Hospital of Dalian Medical University, Dalian 116011, Liaoning Province, China.
| | | | | | | | | |
Collapse
|
31
|
|
32
|
|