1
|
Busenhart K, Brun J, Junker H, Ehret AE, Marcellan A, Mazza E. Collagen hydrogels with similar polymer content but different microstructure - A comparative analysis of mechanical response. J Mech Behav Biomed Mater 2025; 166:106922. [PMID: 39987642 DOI: 10.1016/j.jmbbm.2025.106922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2024] [Revised: 01/16/2025] [Accepted: 01/28/2025] [Indexed: 02/25/2025]
Abstract
Understanding the mechanical properties of collagen hydrogels is essential for successful applications in tissue engineering and 3D cell culture. This study compares the mechanical behavior of two collagen hydrogel sheets with similar collagen content but different microstructures. One of the differences is that one gel is isotropic while the other has collagen fibers oriented towards the sheet's plane. Experiments were performed at macro- (uniaxial tension in the sheet plane) and micro-length scale (AFM-based indentation perpendicular to the plane), and a discrete network model was developed to rationalize the observed differences. The experiments showed an order of magnitude difference in the uniaxial stiffness of the two gels. The softer gel exhibited near-incompressible behavior, while the stiffer gel showed a highly contractile response, with Poisson's ratios around 8. Conversely, the apparent modulus from nano-indentation showed an opposite trend, with higher local stiffness for the gel that was softer in uniaxial tests. The computational model represents the material using a network of bi-linear connectors for the fibrous component and a compressible neo-Hookean material for the surrounding water-rich matrix, assumed to form due to interactions between collagen and water. Under the constraint of equal collagen content, model parameters were tuned to reproduce the observed response of both materials, considering the observed differences in fiber diameter. Importantly, the computations indicate that the difference in collagen orientation cannot explain the observed differences between the mechanical responses of the gels. Successful scaling between the two gels depends on the assumption that, due to their crimped initial state individual fibers primarily experience bending rather than tension when the material is stretched. Moreover, high tensile stretch of the fibers is shown to elicit large lateral contraction. Overall, the results demonstrate the wide range of mechanical properties displayed by hydrogels with similar collagen content, which can be rationalized using discrete models representative of their microstructure.
Collapse
Affiliation(s)
- Kim Busenhart
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich, 8092, Switzerland
| | - Julie Brun
- Sciences et Ingénierie de la Matière Molle, ESPCI Paris PSL University, CNRS, Sorbonne Université, 10 rue Vauquelin, Paris, F-75005, France
| | - Håvar Junker
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich, 8092, Switzerland
| | - Alexander E Ehret
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich, 8092, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, Dübendorf, 8600, Switzerland
| | - Alba Marcellan
- Sciences et Ingénierie de la Matière Molle, ESPCI Paris PSL University, CNRS, Sorbonne Université, 10 rue Vauquelin, Paris, F-75005, France; Institut Universitaire de France (IUF), France
| | - Edoardo Mazza
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich, 8092, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, Dübendorf, 8600, Switzerland.
| |
Collapse
|
2
|
Łysik D, Mystkowska J. Rheological Investigation of Polydimethylsiloxane with Glass Beads: A Model for Compression-Stiffening Effects in Soft Tissue Engineering. MATERIALS (BASEL, SWITZERLAND) 2025; 18:1663. [PMID: 40271940 PMCID: PMC11990219 DOI: 10.3390/ma18071663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2025] [Revised: 03/25/2025] [Accepted: 04/03/2025] [Indexed: 04/25/2025]
Abstract
This study explores the rheological properties of polydimethylsiloxane (PDMS) composites with glass beads (GBs) to replicate the compression-stiffening behavior of biological tissues. The mechanical properties of soft tissues arise from interactions between the extracellular matrix (ECM) and embedded cells. To mimic this, PDMS was used as a polymeric matrix, while rigid GBs acted as non-deformable inclusions facilitating stress redistribution. PDMS composites with 10%, 20%, and 30% GB concentrations were fabricated. Rheological analysis revealed that GBs significantly enhanced the storage modulus (G'), with stiffness increasing linearly under compression. The stiffening rate rose from 300 Pa/% (pure PDMS) to 387 Pa/%, 836 Pa/%, and 2035 Pa/% for 10%, 20%, and 30% GB, respectively, marking a sevenfold increase at the highest concentration. Similarly, the apparent Young's modulus increased from 150 kPa (pure PDMS) to 200 kPa, 300 kPa, and 380 kPa for composites with 10%, 20%, and 30% GB, respectively. PDMS-GB composites successfully reproduce the compression-stiffening effect observed in biological tissues, which may aid research in mechanobiology and tissue engineering.
Collapse
Affiliation(s)
- Dawid Łysik
- Institute of Biomedical Engineering, Bialystok University of Technology, Wiejska 45C, 15-351 Bialystok, Poland;
| | | |
Collapse
|
3
|
Mollenkopf P, Kochanowski JA, Ren Y, Vining KH, Janmey PA, Purohit PK. Poroelasticity and permeability of fibrous polymer networks under compression. SOFT MATTER 2025; 21:2400-2412. [PMID: 39976571 PMCID: PMC11841696 DOI: 10.1039/d4sm01223b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2024] [Accepted: 01/24/2025] [Indexed: 02/23/2025]
Abstract
Soft biopolymer networks play pivotal roles in governing cellular mechanics, tissue structure, and physiological processes such as blood coagulation. Understanding their permeability and mechanical responses under compression is crucial for elucidating mass transport phenomena and their impact on extra- and intra-cellular behavior as well as processes affecting functionality of blood clots, cartilage and other fibrous tissues. The nonlinear responses of these networks to mechanical stresses prevent application of established linear poro-elasticity models. Despite extensive studies of fibrous network viscoelastic properties under shear deformations, their dynamic responses to compressive deformations remain poorly understood, particularly in physiological contexts of growth and collective migration of solid bodies. Conventional experimental techniques face challenges in accurately evaluating the permeability of these networks, hindering comprehensive understanding of their poromechanical behavior. In this study, we employ a novel poroelastic hybrid approach combining rheometer-based compression rheology with camera-facilitated sample shape detection to directly measure fluid flux and network permeability under controlled compressive strains. Accompanying experimental investigations, a continuum model implemented in finite elements, and an analytical model are developed to interpret the findings. The experimental data align well with the analytical model, revealing the emergence and disappearance of distinct densification regimes within the gel under mechanical stress. This study advances our understanding of the intricate interplay between mechanical forces, fluid flow, and structural properties in soft biopolymer networks, with a specific focus on fibrin- and collagen-based gels which represent the most abundant protein networks in the extracellular environment.
Collapse
Affiliation(s)
- Paul Mollenkopf
- Department of Physiology, University of Pennsylvania, Philadelphia, PA, 19104, USA.
| | - Jakub A Kochanowski
- Department of Physiology, University of Pennsylvania, Philadelphia, PA, 19104, USA.
| | - Yifei Ren
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Kyle H Vining
- Department of Preventive and Restorative Sciences, Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Paul A Janmey
- Department of Physiology, University of Pennsylvania, Philadelphia, PA, 19104, USA.
- Department of Physics & Astronomy, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Prashant K Purohit
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
4
|
Kaiser AH, Bourauel C. Towards a reduced order model of the periodontal ligament. Sci Rep 2025; 15:5779. [PMID: 39962174 PMCID: PMC11833108 DOI: 10.1038/s41598-025-88767-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2024] [Accepted: 01/30/2025] [Indexed: 02/20/2025] Open
Abstract
Based on previous in vitro experiments with specimens of porcine mandibular premolars, the simulation of the periodontal ligament response to force in the initial phase of orthodontic tooth movement is described. The initial response of the periodontal ligament can be simulated with a poro-visco-hyperelastic model. For the ground substance a hyperelastic constitutive model for compressible material was used. To facilitate parameter identification a reduced order model and an optimal interpolation metamodel were used. Parameters for the constitutive model identified herein are in good agreement with published values. They indicate a high initial compressibility of the periodontal ligament, which may be attributed to the compressibility of the vascular system within the periodontal ligament. Dimensionless analysis suggests that poroelastic behaviour will gradually cease when viscoelastic relaxation progresses. This was observed as well in the simulation and confirmed by varying the poroelastic model parameters within physically justified limits. Alveolar bone permeability has a significant influence on the flow of pore fluid in the periodontium due to poroelasticity. It is argued that in vivo alveolar bone perforation may adapt locally to optimise for the predominant load situation. A strain rate hardening effect was observed, which is not covered by the simulation, and may be the subject of further investigations.
Collapse
Affiliation(s)
- Albert Heinrich Kaiser
- Institute for Numerical Simulation, University Bonn, Friedrich-Hirzebruch-Allee 7, 53115, Bonn, Germany.
| | - Christoph Bourauel
- Oral Technology, University Hospital Bonn, Welschnonnenstr. 17, D 53111, Bonn, Germany
| |
Collapse
|
5
|
Garau Paganella L, Badolato A, Labouesse C, Fischer G, Sänger CS, Kourouklis A, Giampietro C, Werner S, Mazza E, Tibbitt MW. Variations in fluid chemical potential induce fibroblast mechano-response in 3D hydrogels. BIOMATERIALS ADVANCES 2024; 163:213933. [PMID: 38972277 DOI: 10.1016/j.bioadv.2024.213933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 05/28/2024] [Accepted: 06/25/2024] [Indexed: 07/09/2024]
Abstract
Mechanical deformation of skin creates variations in fluid chemical potential, leading to local changes in hydrostatic and osmotic pressure, whose effects on mechanobiology remain poorly understood. To study these effects, we investigate the specific influences of hydrostatic and osmotic pressure on primary human dermal fibroblasts in three-dimensional hydrogel culture models. Cyclic hydrostatic pressure and hyperosmotic stress enhanced the percentage of cells expressing the proliferation marker Ki67 in both collagen and PEG-based hydrogels. Osmotic pressure also activated the p38 MAPK stress response pathway and increased the expression of the osmoresponsive genes PRSS35 and NFAT5. When cells were cultured in two-dimension (2D), no change in proliferation was observed with either hydrostatic or osmotic pressure. Furthermore, basal, and osmotic pressure-induced expression of osmoresponsive genes differed in 2D culture versus 3D hydrogels, highlighting the role of dimensionality in skin cell mechanotransduction and stressing the importance of 3D tissue-like models that better replicate in vivo conditions. Overall, these results indicate that fluid chemical potential changes affect dermal fibroblast mechanobiology, which has implications for skin function and for tissue regeneration strategies.
Collapse
Affiliation(s)
- Lorenza Garau Paganella
- Macromolecular Engineering Laboratory, Institute of Energy and Process Engineering, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland; Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Asia Badolato
- Macromolecular Engineering Laboratory, Institute of Energy and Process Engineering, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Céline Labouesse
- Macromolecular Engineering Laboratory, Institute of Energy and Process Engineering, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Gabriel Fischer
- Macromolecular Engineering Laboratory, Institute of Energy and Process Engineering, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Catharina S Sänger
- Institute of Molecular Health Sciences, Department of Biology, ETH Zurich, Zurich, Switzerland
| | - Andreas Kourouklis
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Costanza Giampietro
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland; EMPA, Swiss Federal Laboratories for Material Science and Technologies, Dubendorf, Switzerland
| | - Sabine Werner
- Institute of Molecular Health Sciences, Department of Biology, ETH Zurich, Zurich, Switzerland
| | - Edoardo Mazza
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland; EMPA, Swiss Federal Laboratories for Material Science and Technologies, Dubendorf, Switzerland
| | - Mark W Tibbitt
- Macromolecular Engineering Laboratory, Institute of Energy and Process Engineering, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland.
| |
Collapse
|
6
|
Martyts A, Sachs D, Hiebert P, Junker H, Robmann S, Hopf R, Steenbock H, Brinckmann J, Werner S, Giampietro C, Mazza E. Biomechanical and biochemical changes in murine skin during development and aging. Acta Biomater 2024; 186:316-329. [PMID: 39009208 DOI: 10.1016/j.actbio.2024.07.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 06/21/2024] [Accepted: 07/10/2024] [Indexed: 07/17/2024]
Abstract
Aging leads to biochemical and biomechanical changes in skin, with biological and functional consequences. Despite extensive literature on skin aging, there is a lack of studies which investigate the maturation of the tissue and connect the microscopic changes in the skin to its macroscopic biomechanical behavior as it evolves over time. The present work addresses this knowledge gap using multiscale characterization of skin in a murine model considering newborn, adult and aged mice. Monotonic uniaxial loading, tension relaxation with change of bath, and loading to failure tests were performed on murine skin samples from different age groups, complemented by inflation experiments and atomic force microscopy indentation measurements. In parallel, skin samples were characterized using histological and biochemical techniques to assess tissue morphology, collagen organization, as well as collagen content and cross-linking. We show that 1-week-old skin differs across nearly all measured parameters from adult skin, showing reduced strain stiffening and tensile strength, a thinner dermis, lower collagen content and altered crosslinking patterns. Surprisingly, adult and aged skin were similar across most biomechanical parameters in the physiologic loading range, while aged skin had lower tensile strength and lower stiffening behavior at large force values. This correlates with altered collagen content and cross-links. Based on a computational model, differences in mechanocoupled stimuli in the skin of the different age groups were calculated, pointing to a potential biological significance of the age-induced biomechanical changes in regulating the local biophysical environment of dermal cells. STATEMENT OF SIGNIFICANCE: Skin microstructure and the emerging mechanical properties change with age, leading to biological, functional and health-related consequences. Despite extensive literature on skin aging, only very limited quantitative data are available on microstructural changes and the corresponding macroscopic biomechanical behavior as they evolve over time. This work provides a wide-range multiscale mechanical characterization of skin of newborn, adult and aged mice, and quantifies microstructural correlations in tissue morphology, collagen content, organization and cross-linking. Remarkably, aged skin retained normal hydration and normal biomechanical function in the physiological loading range but showed significantly reduced properties at super-physiological loading. Our data show that age-related microstructural differences have a profound effect not only on tissue-level properties but also on the cell-level biophysical environment.
Collapse
Affiliation(s)
- Anastasiya Martyts
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zürich, 8092 Zürich, Switzerland
| | - David Sachs
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zürich, 8092 Zürich, Switzerland
| | - Paul Hiebert
- Institute of Molecular Health Sciences, Department of Biology, ETH Zürich, 8093 Zürich, Switzerland
| | - Håvar Junker
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zürich, 8092 Zürich, Switzerland
| | - Serjosha Robmann
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zürich, 8092 Zürich, Switzerland
| | - Raoul Hopf
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zürich, 8092 Zürich, Switzerland
| | - Heiko Steenbock
- Institute of Virology and Cell Biology, University of Lübeck, 23562 Lübeck, Germany
| | - Jürgen Brinckmann
- Institute of Virology and Cell Biology, University of Lübeck, 23562 Lübeck, Germany; Department of Dermatology, University of Lübeck, 23562 Lübeck, Germany
| | - Sabine Werner
- Institute of Molecular Health Sciences, Department of Biology, ETH Zürich, 8093 Zürich, Switzerland
| | - Costanza Giampietro
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zürich, 8092 Zürich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600 Dübendorf, Switzerland
| | - Edoardo Mazza
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zürich, 8092 Zürich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600 Dübendorf, Switzerland.
| |
Collapse
|
7
|
Alberini R, Spagnoli A, Sadeghinia MJ, Skallerud B, Terzano M, Holzapfel GA. Second harmonic generation microscopy, biaxial mechanical tests and fiber dispersion models in human skin biomechanics. Acta Biomater 2024; 185:266-280. [PMID: 39048027 DOI: 10.1016/j.actbio.2024.07.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 07/13/2024] [Accepted: 07/16/2024] [Indexed: 07/27/2024]
Abstract
Advanced numerical simulations of the mechanical behavior of human skin require thorough calibration of the material's constitutive models based on experimental ex vivo mechanical tests along with images of tissue microstructure for a variety of biomedical applications. In this work, a total of 14 human healthy skin samples and 4 additional scarred skin samples were experimentally analyzed to gain deep insights into the biomechanics of human skin. In particular, second harmonic generation (SHG) microscopy was used to extract detailed images of the distribution of collagen fibers, which were subsequently processed using a three-dimensional Fourier transform-based method recently proposed by the authors to quantify the distribution of fiber orientations. Mechanical tests under both biaxial and uniaxial loading were performed to calibrate the relevant mechanical parameters of two widely used constitutive models of soft fiber-reinforced biological tissues that account for non-symmetrical fiber dispersion. The calibration of the models allowed us to identify correlations between the mechanical parameters of the constitutive models considered. STATEMENT OF SIGNIFICANCE: Constitutive models for soft collagenous tissues can accurately reproduce the complex nonlinear and anisotropic mechanical behavior of skin. However, a comprehensive analysis of both microstructural and mechanical parameters is still missing for human skin. In this study, these parameters are determined by combining biaxial mechanical tests and SHG stacks of collagen fibers on ex vivo healthy human skin samples. The constitutive parameters are provided for two widely used hyperelastic models and enable accurate characterization of skin mechanical behavior for advanced numerical simulations.
Collapse
Affiliation(s)
- Riccardo Alberini
- Department of Engineering and Architecture, University of Parma, Parma, Italy
| | - Andrea Spagnoli
- Department of Engineering and Architecture, University of Parma, Parma, Italy.
| | - Mohammad Javad Sadeghinia
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Bjorn Skallerud
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Michele Terzano
- Institute of Biomechanics, Graz University of Technology, Graz, Austria
| | - Gerhard A Holzapfel
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway; Institute of Biomechanics, Graz University of Technology, Graz, Austria
| |
Collapse
|
8
|
Sachs D, Jakob R, Restivo G, Hafner J, Lindenblatt N, Ehret AE, Mazza E. A quadriphasic mechanical model of the human dermis. Biomech Model Mechanobiol 2024; 23:1121-1136. [PMID: 38489079 PMCID: PMC11584490 DOI: 10.1007/s10237-024-01827-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 02/09/2024] [Indexed: 03/17/2024]
Abstract
The present study investigates the multiphasic nature of the mechanical behavior of human dermis. Motivated by experimental observations and by consideration of its composition, a quadriphasic model of the dermis is proposed, distinguishing solid matrix components, interstitial fluid and charged constituents moving within the fluid, i.e., anions and cations. Compression and tensile experiments with and without change of osmolarity of the bath are performed to characterize the chemo-mechanical coupling in the dermis. Model parameters are determined through inverse analysis. The computations predict a dominant role of the permeability in the determination of the temporal evolution of the mechanical response of the tissue. In line with the previous studies on other tissues, the analysis shows that an ideal model based on Donnan's equilibrium overestimates the osmotic pressure in skin for the case of very dilute solutions. The quadriphasic model is applied to predict changes in dermal cell environment and therefore alterations in what is called the "mechanome," associated with skin stretch. The simulations indicate that skin deformation causes a variation in several local variables, including in particular the electric field associated with a deformation-induced non-homogeneous distribution of fixed charges.
Collapse
Affiliation(s)
- David Sachs
- Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland.
| | - Raphael Jakob
- Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland
| | - Gaetana Restivo
- Department of Dermatology, University Hospital Zürich, Zurich, Switzerland
| | - Jürg Hafner
- Department of Dermatology, University Hospital Zürich, Zurich, Switzerland
| | - Nicole Lindenblatt
- Department of Plastic Surgery and Hand Surgery, University Hospital Zürich, Zurich, Switzerland
| | - Alexander E Ehret
- Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland
- Swiss Federal Laboratories for Materials Science and Technology, Experimental Continuum Mechanics, Dübendorf, Switzerland
| | - Edoardo Mazza
- Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland.
- Swiss Federal Laboratories for Materials Science and Technology, Experimental Continuum Mechanics, Dübendorf, Switzerland.
| |
Collapse
|
9
|
Witt NJ, Woessner AE, Herrmann J, Quinn KP, Sander EA. Mechanical Models of Collagen Networks for Understanding Changes in the Failure Properties of Aging Skin. J Biomech Eng 2024; 146:071002. [PMID: 38183223 PMCID: PMC10983714 DOI: 10.1115/1.4064406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/19/2023] [Accepted: 12/27/2023] [Indexed: 01/07/2024]
Abstract
Skin undergoes mechanical alterations due to changes in the composition and structure of the collagenous dermis with aging. Previous studies have conflicting findings, with both increased and decreased stiffness reported for aging skin. The underlying structure-function relationships that drive age-related changes are complex and difficult to study individually. One potential contributor to these variations is the accumulation of nonenzymatic crosslinks within collagen fibers, which affect dermal collagen remodeling and mechanical properties. Specifically, these crosslinks make individual fibers stiffer in their plastic loading region and lead to increased fragmentation of the collagenous network. To better understand the influence of these changes, we investigated the impact of nonenzymatic crosslink changes on the dermal microstructure using discrete fiber networks representative of the dermal microstructure. Our findings suggest that stiffening the plastic region of collagen's mechanical response has minimal effects on network-level stiffness and failure stresses. Conversely, simulating fragmentation through a loss of connectivity substantially reduces network stiffness and failure stress, while increasing stretch ratios at failure.
Collapse
Affiliation(s)
- Nathan J. Witt
- Roy J. Carver Department of Biomedical Engineering, College of Engineering, University of Iowa, Iowa City, IA 52240
| | - Alan E. Woessner
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR 72701
| | - Jacob Herrmann
- Roy J. Carver Department of Biomedical Engineering, College of Engineering, University of Iowa, Iowa City, IA 52242
| | - Kyle P. Quinn
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR 72701
| | - Edward A. Sander
- Roy J. Carver Department of Biomedical Engineering, College of Engineering, University of Iowa, 5629 Seamans Center, Iowa City, IA 52242; Department of Orthopedics and Rehabilitation, Carver College of Medicine, University of Iowa, Iowa City, IA 52242
| |
Collapse
|
10
|
Crossley RM, Johnson S, Tsingos E, Bell Z, Berardi M, Botticelli M, Braat QJS, Metzcar J, Ruscone M, Yin Y, Shuttleworth R. Modeling the extracellular matrix in cell migration and morphogenesis: a guide for the curious biologist. Front Cell Dev Biol 2024; 12:1354132. [PMID: 38495620 PMCID: PMC10940354 DOI: 10.3389/fcell.2024.1354132] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 02/12/2024] [Indexed: 03/19/2024] Open
Abstract
The extracellular matrix (ECM) is a highly complex structure through which biochemical and mechanical signals are transmitted. In processes of cell migration, the ECM also acts as a scaffold, providing structural support to cells as well as points of potential attachment. Although the ECM is a well-studied structure, its role in many biological processes remains difficult to investigate comprehensively due to its complexity and structural variation within an organism. In tandem with experiments, mathematical models are helpful in refining and testing hypotheses, generating predictions, and exploring conditions outside the scope of experiments. Such models can be combined and calibrated with in vivo and in vitro data to identify critical cell-ECM interactions that drive developmental and homeostatic processes, or the progression of diseases. In this review, we focus on mathematical and computational models of the ECM in processes such as cell migration including cancer metastasis, and in tissue structure and morphogenesis. By highlighting the predictive power of these models, we aim to help bridge the gap between experimental and computational approaches to studying the ECM and to provide guidance on selecting an appropriate model framework to complement corresponding experimental studies.
Collapse
Affiliation(s)
- Rebecca M. Crossley
- Wolfson Centre for Mathematical Biology, Mathematical Institute, University of Oxford, Oxford, United Kingdom
| | - Samuel Johnson
- Wolfson Centre for Mathematical Biology, Mathematical Institute, University of Oxford, Oxford, United Kingdom
| | - Erika Tsingos
- Computational Developmental Biology Group, Institute of Biodynamics and Biocomplexity, Utrecht University, Utrecht, Netherlands
| | - Zoe Bell
- Northern Institute for Cancer Research, Newcastle University, Newcastle upon Tyne, United Kingdom
| | - Massimiliano Berardi
- LaserLab, Department of Physics and Astronomy, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
- Optics11 life, Amsterdam, Netherlands
| | | | - Quirine J. S. Braat
- Department of Applied Physics and Science Education, Eindhoven University of Technology, Eindhoven, Netherlands
| | - John Metzcar
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, United States
- Department of Informatics, Indiana University, Bloomington, IN, United States
| | | | - Yuan Yin
- Wolfson Centre for Mathematical Biology, Mathematical Institute, University of Oxford, Oxford, United Kingdom
| | | |
Collapse
|
11
|
Garyfallogiannis K, Purohit PK, Bassani JL. Cracks in tensile-contracting and tensile-dilating poroelastic materials. INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES 2024; 286-287:112563. [PMID: 38130319 PMCID: PMC10732463 DOI: 10.1016/j.ijsolstr.2023.112563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
Fibrous gels such as cartilage, blood clots, and carbon-nanotube-based sponges with absorbed oils suffer a reduction in volume by the expulsion of liquid under uniaxial tension, and this directly affects crack-tip fields and energy release rates. A continuum model is formulated for isotropic fibrous gels that exhibit a range of behaviors from volume increasing to volume decreasing in uniaxial tension by changing the ratio of two material parameters. The motion of liquid in the pores of such gels is modeled using poroelasticity. The direction of liquid fluxes around cracks is shown to depend on whether the gel locally increases or decreases in volume. The energy release rate for cracks is computed using a surface-independent integral and it is shown to have two contributions - one from the stresses in the solid network, and another from the flow of liquid. The contribution to the integral from liquid permeation tends to be negative when the gel exhibits volume decrease, which effectively is a crack shielding mechanism.
Collapse
Affiliation(s)
| | - Prashant K. Purohit
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - John L. Bassani
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
12
|
de Lucio M, Leng Y, Wang H, Ardekani AM, Vlachos PP, Shi G, Gomez H. Computational modeling of the effect of skin pinch and stretch on subcutaneous injection of monoclonal antibodies using autoinjector devices. Biomech Model Mechanobiol 2023; 22:1965-1982. [PMID: 37526775 DOI: 10.1007/s10237-023-01746-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 07/06/2023] [Indexed: 08/02/2023]
Abstract
Subcutaneous injection of monoclonal antibodies (mAbs) has experienced unprecedented growth in the pharmaceutical industry due to its benefits in patient compliance and cost-effectiveness. However, the impact of different injection techniques and autoinjector devices on the drug's transport and uptake is poorly understood. Here, we develop a biphasic large-deformation chemomechanical model that accounts for the components of the extracellular matrix that govern solid deformation and fluid flow within the subcutaneous tissue: interstitial fluid, collagen fibers and negatively charged proteoglycan aggregates. We use this model to build a high-fidelity representation of a virtual patient performing a subcutaneous injection of mAbs. We analyze the impact of the pinch and stretch methods on the injection dynamics and the use of different handheld autoinjector devices. The results suggest that autoinjector base plates with a larger device-skin contact area cause significantly lower tissue mechanical stress, fluid pressure and fluid velocity during the injection process. Our simulations indicate that the stretch technique presents a higher risk of intramuscular injection for autoinjectors with a relatively long needle insertion depth.
Collapse
Affiliation(s)
- Mario de Lucio
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Yu Leng
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Hao Wang
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Arezoo M Ardekani
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Pavlos P Vlachos
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA
| | - Galen Shi
- Eli Lilly and Company, Indianapolis, IN, USA
| | - Hector Gomez
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN, 47907, USA.
| |
Collapse
|
13
|
Wahlsten A, Stracuzzi A, Lüchtefeld I, Restivo G, Lindenblatt N, Giampietro C, Ehret AE, Mazza E. Multiscale mechanical analysis of the elastic modulus of skin. Acta Biomater 2023; 170:155-168. [PMID: 37598792 DOI: 10.1016/j.actbio.2023.08.030] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Revised: 07/27/2023] [Accepted: 08/15/2023] [Indexed: 08/22/2023]
Abstract
The mechanical properties of the skin determine tissue function and regulate dermal cell behavior. Yet measuring these properties remains challenging, as evidenced by the large range of elastic moduli reported in the literature-from below one kPa to hundreds of MPa. Here, we reconcile these disparate results by dedicated experiments at both tissue and cellular length scales and by computational models considering the multiscale and multiphasic tissue structure. At the macroscopic tissue length scale, the collective behavior of the collagen fiber network under tension provides functional tissue stiffness, and its properties determine the corresponding elastic modulus (100-200 kPa). The compliant microscale environment (0.1-10 kPa), probed by atomic force microscopy, arises from the ground matrix without engaging the collagen fiber network. Our analysis indicates that indentation-based elasticity measurements, although probing tissue properties at the cell-relevant length scale, do not assess the deformation mechanisms activated by dermal cells when exerting traction forces on the extracellular matrix. Using dermal-equivalent collagen hydrogels, we demonstrate that indentation measurements of tissue stiffness do not correlate with the behavior of embedded dermal fibroblasts. These results provide a deeper understanding of tissue mechanics across length scales with important implications for skin mechanobiology and tissue engineering. STATEMENT OF SIGNIFICANCE: Measuring the mechanical properties of the skin is essential for understanding dermal cell mechanobiology and designing tissue-engineered skin substitutes. However, previous results reported for the elastic modulus of skin vary by six orders of magnitude. We show that two distinct deformation mechanisms, related to the tension-compression nonlinearity of the collagen fiber network, can explain the large variations in elastic moduli. Furthermore, we show that microscale indentation, which is frequently used to assess the stiffness perceived by cells, fails to engage the fiber network, and therefore cannot predict the behavior of dermal fibroblasts in stiffness-tunable fibrous hydrogels. This has important implications for how to measure and interpret the mechanical properties of soft tissues across length scales.
Collapse
Affiliation(s)
- Adam Wahlsten
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich 8092, Switzerland
| | - Alberto Stracuzzi
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich 8092, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, Dübendorf 8600, Switzerland
| | - Ines Lüchtefeld
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Gloriastrasse 35, Zurich 8092, Switzerland
| | - Gaetana Restivo
- Department of Dermatology, University Hospital Zurich, Zurich 8091, Switzerland
| | - Nicole Lindenblatt
- Department of Plastic and Hand Surgery, University Hospital Zurich, Zurich 8091, Switzerland
| | - Costanza Giampietro
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich 8092, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, Dübendorf 8600, Switzerland
| | - Alexander E Ehret
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich 8092, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, Dübendorf 8600, Switzerland
| | - Edoardo Mazza
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, Zurich 8092, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, Dübendorf 8600, Switzerland.
| |
Collapse
|
14
|
Garyfallogiannis K, Ramanujam RK, Litvinov RI, Yu T, Nagaswami C, Bassani JL, Weisel JW, Purohit PK, Tutwiler V. Fracture toughness of fibrin gels as a function of protein volume fraction: Mechanical origins. Acta Biomater 2023; 159:49-62. [PMID: 36642339 PMCID: PMC11824895 DOI: 10.1016/j.actbio.2022.12.028] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 12/09/2022] [Accepted: 12/15/2022] [Indexed: 01/15/2023]
Abstract
The mechanical stability of blood clots necessary for their functions is provided by fibrin, a fibrous gel. Rupture of clots leads to life-threatening thrombotic embolization, which is little understood. Here, we combine experiments and simulations to determine the toughness of plasma clots as a function of fibrin content and correlate toughness with fibrin network structure characterized by confocal and scanning electron microscopy. We develop fibrin constitutive laws that scale with fibrin concentration and capture the force-stretch response of cracked clot specimens using only a few material parameters. Toughness is calculated from the path-independent J* integral that includes dissipative effects due to fluid flow and uses only the constitutive model and overall stretch at crack propagation as input. We show that internal fluid motion, which is not directly measurable, contributes significantly to clot toughness, with its effect increasing as fibrin content increases, because the reduced gel porosity at higher density results in greater expense of energy in fluid motion. Increasing fibrin content (1→10mg/mL) results in a significant increase in clot toughness (3→15 N/m) in accordance with a power law relation reminiscent of cellular solids and elastomeric gels. These results provide a basis for understanding and predicting the tendency for thrombotic embolization. STATEMENT OF SIGNIFICANCE: Fibrin, a naturally occurring biomaterial, is the major determinant of the structural and mechanical integrity of blood clots. We determined that increasing the fibrin content in clots, as in some thrombi and fibrin-based anti-bleeding sealants, results in an increase in clot toughness. Toughness corresponds to the ability to resist rupturing in the presence of a defect. We couple bulk mechanical testing, microstructural measurements, and finite element modeling to capture the force-stretch response of fibrin clots and compute toughness. We show that increased fibrin content in clots reduces porosity and limits fluid motion and that fluid motion drastically alters the clot toughness. These results provide a fundamental understanding of blood clot rupture and could help in rational design of fibrin-containing biomaterials.
Collapse
Affiliation(s)
| | - Ranjini K Ramanujam
- Department of Biomedical Engineering, Rutgers University, Piscataway, NJ, USA
| | - Rustem I Litvinov
- Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, PA, USA
| | - Tony Yu
- Department of Biomedical Engineering, Rutgers University, Piscataway, NJ, USA
| | | | - John L Bassani
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA, USA
| | - John W Weisel
- Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, PA, USA
| | - Prashant K Purohit
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA, USA
| | - Valerie Tutwiler
- Department of Biomedical Engineering, Rutgers University, Piscataway, NJ, USA.
| |
Collapse
|
15
|
Da Silva Pinto B, Ronsin O, Baumberger T. Syneresis of self-crowded calcium-alginate hydrogels as a self-driven athermal aging process. SOFT MATTER 2023; 19:1720-1731. [PMID: 36779517 DOI: 10.1039/d2sm01496c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The assembly of biopolymers into a hydrated elastic network often goes along with syneresis, a spontaneous process during which the hydrogel slowly shrinks and releases solvent. The tendency to syneresis of calcium-alginate hydrogels, widely used biocompatible materials, is a hindrance to applications for which dimensional integrity is crucial. Although calcium-induced aggregation of specific block-sequences has been long known as the microscopic process at work in both primary cross-linking and syneresis, the nature of the coupling between these structural events and the global deswelling flow has remained so far elusive. We have tackled this issue within the regime of entangled pregels that yield highly cross-linked, self-crowded hydrogels with stiff networks. Using an original, stopped-flow extrusion experiment, we have unveiled a robust, stretched-exponential kinetics of shrinking, spanning more than six decades of time and quasi-independent of the alginate concentration. A careful analysis of the puzzling dynamical features of syneresis in these gels has led us to propose that due to the network rigidity, the calcium-fueled, random collapse events that drive solvent locally, are not thermally activated but rather controlled by the average poroelastic flow itself, according to a self-sustained mechanism described here for the first time.
Collapse
Affiliation(s)
- Bruno Da Silva Pinto
- Sorbonne Université, CNRS, Institut des nanosciences de Paris, 4, place Jussieu, F-75005 Paris, France.
- Université Paris Cité, F-75006 Paris, France
| | - Olivier Ronsin
- Sorbonne Université, CNRS, Institut des nanosciences de Paris, 4, place Jussieu, F-75005 Paris, France.
- Université Paris Cité, F-75006 Paris, France
| | - Tristan Baumberger
- Sorbonne Université, CNRS, Institut des nanosciences de Paris, 4, place Jussieu, F-75005 Paris, France.
- Université Paris Cité, F-75006 Paris, France
| |
Collapse
|
16
|
Kourouklis AP, Wahlsten A, Stracuzzi A, Martyts A, Paganella LG, Labouesse C, Al-Nuaimi D, Giampietro C, Ehret AE, Tibbitt MW, Mazza E. Control of hydrostatic pressure and osmotic stress in 3D cell culture for mechanobiological studies. BIOMATERIALS ADVANCES 2023; 145:213241. [PMID: 36529095 DOI: 10.1016/j.bioadv.2022.213241] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 10/25/2022] [Accepted: 12/09/2022] [Indexed: 12/15/2022]
Abstract
Hydrostatic pressure (HP) and osmotic stress (OS) play an important role in various biological processes, such as cell proliferation and differentiation. In contrast to canonical mechanical signals transmitted through the anchoring points of the cells with the extracellular matrix, the physical and molecular mechanisms that transduce HP and OS into cellular functions remain elusive. Three-dimensional cell cultures show great promise to replicate physiologically relevant signals in well-defined host bioreactors with the goal of shedding light on hidden aspects of the mechanobiology of HP and OS. This review starts by introducing prevalent mechanisms for the generation of HP and OS signals in biological tissues that are subject to pathophysiological mechanical loading. We then revisit various mechanisms in the mechanotransduction of HP and OS, and describe the current state of the art in bioreactors and biomaterials for the control of the corresponding physical signals.
Collapse
Affiliation(s)
- Andreas P Kourouklis
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland.
| | - Adam Wahlsten
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland
| | - Alberto Stracuzzi
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland
| | - Anastasiya Martyts
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland
| | - Lorenza Garau Paganella
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland; Macromolecular Engineering Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zurich, Switzerland
| | - Celine Labouesse
- Macromolecular Engineering Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zurich, Switzerland
| | - Dunja Al-Nuaimi
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland
| | - Costanza Giampietro
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland
| | - Alexander E Ehret
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland
| | - Mark W Tibbitt
- Macromolecular Engineering Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zurich, Switzerland
| | - Edoardo Mazza
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland
| |
Collapse
|
17
|
Erlich A, Étienne J, Fouchard J, Wyatt T. How dynamic prestress governs the shape of living systems, from the subcellular to tissue scale. Interface Focus 2022; 12:20220038. [PMID: 36330322 PMCID: PMC9560792 DOI: 10.1098/rsfs.2022.0038] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 09/08/2022] [Indexed: 10/16/2023] Open
Abstract
Cells and tissues change shape both to carry out their function and during pathology. In most cases, these deformations are driven from within the systems themselves. This is permitted by a range of molecular actors, such as active crosslinkers and ion pumps, whose activity is biologically controlled in space and time. The resulting stresses are propagated within complex and dynamical architectures like networks or cell aggregates. From a mechanical point of view, these effects can be seen as the generation of prestress or prestrain, resulting from either a contractile or growth activity. In this review, we present this concept of prestress and the theoretical tools available to conceptualize the statics and dynamics of living systems. We then describe a range of phenomena where prestress controls shape changes in biopolymer networks (especially the actomyosin cytoskeleton and fibrous tissues) and cellularized tissues. Despite the diversity of scale and organization, we demonstrate that these phenomena stem from a limited number of spatial distributions of prestress, which can be categorized as heterogeneous, anisotropic or differential. We suggest that in addition to growth and contraction, a third type of prestress-topological prestress-can result from active processes altering the microstructure of tissue.
Collapse
Affiliation(s)
| | - Jocelyn Étienne
- Université Grenoble Alpes, CNRS, LIPHY, 38000 Grenoble, France
| | - Jonathan Fouchard
- Laboratoire de Biologie du Développement, Institut de Biologie Paris Seine (IBPS), Sorbonne Université, CNRS (UMR 7622), INSERM (URL 1156), 7 quai Saint Bernard, 75005 Paris, France
| | - Tom Wyatt
- Wellcome Trust–Medical Research Council Cambridge Stem Cell Institute, University of Cambridge, Cambridge, UK
| |
Collapse
|
18
|
Hiebert P, Martyts A, Schwestermann J, Janke K, Hafner J, Boukamp P, Mazza E, Werner S. Activation of Nrf2 in fibroblasts promotes a skin aging phenotype via an Nrf2-miRNA-collagen axis. Matrix Biol 2022; 113:39-60. [PMID: 36367485 DOI: 10.1016/j.matbio.2022.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 09/08/2022] [Accepted: 09/12/2022] [Indexed: 12/30/2022]
Abstract
Aging is associated with progressive skin fragility and a tendency to tear, which can lead to severe clinical complications. The transcription factor NRF2 is a key regulator of the cellular antioxidant response, and pharmacological NRF2 activation is a promising strategy for the prevention of age-related diseases. Using a combination of molecular and cellular biology, histology, imaging and biomechanical studies we show, however, that constitutive genetic activation of Nrf2 in fibroblasts of mice suppresses collagen and elastin expression, resulting in reduced skin strength as seen in aged mice. Mechanistically, the "aging matrisome" results in part from direct Nrf2-mediated overexpression of a network of microRNAs that target mRNAs of major skin collagens and other matrix components. Bioinformatics and functional studies revealed high NRF2 activity in aged human fibroblasts in 3D skin equivalents and human skin biopsies, highlighting the translational relevance of the functional mouse data. Together, these results identify activated NRF2 as a promoter of age-related molecular and biomechanical skin features.
Collapse
Affiliation(s)
- Paul Hiebert
- Department of Biology, Institute of Molecular Health Sciences, ETH Zurich, Zurich 8093, Switzerland.
| | - Anastasiya Martyts
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, Zurich 8092, Switzerland
| | - Jonas Schwestermann
- Department of Biology, Institute of Molecular Health Sciences, ETH Zurich, Zurich 8093, Switzerland
| | - Katharina Janke
- Department of Environmentally-Induced Skin and Lung Aging, IUF - Leibniz Research Institute for Environmental Medicine, Düsseldorf 40225, Germany
| | - Jürg Hafner
- Department of Dermatology, University Hospital Zurich, Zurich 8091, Switzerland
| | - Petra Boukamp
- Department of Environmentally-Induced Skin and Lung Aging, IUF - Leibniz Research Institute for Environmental Medicine, Düsseldorf 40225, Germany
| | - Edoardo Mazza
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, Zurich 8092, Switzerland
| | - Sabine Werner
- Department of Biology, Institute of Molecular Health Sciences, ETH Zurich, Zurich 8093, Switzerland
| |
Collapse
|
19
|
Abstract
A number of biological tissues and synthetic gels consist of a fibrous network infused with liquid. There have been a few experimental studies of the rheological properties of such gels under applied compressive strain. Their results suggest that a plot of rheological moduli as a function of applied compressive strain has a long plateau flanked by a steeply increasing curve for large compressive strains and a slowly decreasing curve for small strains. In this paper we explain these trends in rheological properties using a chemo-elastic model characterized by a double-well strain energy function for the underlying fibrous network. The wells correspond to rarefied and densified phases of the fibrous network at low and high strains, respectively. These phases can co-exist across a movable transition front in the gel in order to accommodate overall applied compression. We find that the rheological properties of fibrous gels share similarities with a Kelvin-Voigt visco-elastic solid. The storage modulus has its origins in the elasticity of the fibrous network, while the loss modulus is determined by the dissipation caused by liquid flow through pores. The rheological properties can depend on the number of phase transition fronts present in a compressed sample. Our analysis may explain the dependence of storage and loss moduli of fibrin gels on the loading history. We also point to the need for combining rheological measurements on gels with a microstructural analysis that could shed light on various dissipation mechanisms.
Collapse
|
20
|
Böl M, Kohn S, Leichsenring K, Morales-Orcajo E, Ehret AE. On multiscale tension-compression asymmetry in skeletal muscle. Acta Biomater 2022; 144:210-220. [PMID: 35339701 DOI: 10.1016/j.actbio.2022.03.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 03/11/2022] [Accepted: 03/17/2022] [Indexed: 11/17/2022]
Abstract
Skeletal muscle tissue shows a clear asymmetry with regard to the passive stresses under tensile and compressive deformation, referred to as tension-compression asymmetry (TCA). The present study is the first one reporting on TCA at different length scales, associated with muscle tissue and muscle fibres, respectively. This allows for the first time the comparison of TCA between the tissue and one of its individual components, and thus to identify the length scale at which this phenomenon originates. Not only the passive stress-stretch characteristics were recorded, but also the volume changes during the axial tension and compression experiments. The study reveals clear differences in the characteristics of TCA between fibres and tissue. At tissue level TCA increases non-linearly with increasing deformation and the ratio of tensile to compressive stresses at the same magnitude of strain reaches a value of approximately 130 at 13.5% deformation. At fibre level instead it initially drops to a value of 6 and then rises again to a TCA of 14. At a deformation of 13.5%, the tensile stress is about 6 times higher. Thus, TCA is about 22 times more expressed at tissue than fibre scale. Moreover, the analysis of volume changes revealed little compressibility at tissue scale whereas at fibre level, especially under compressive stress, the volume decreases significantly. The data collected in this study suggests that the extracellular matrix has a distinct role in amplifying the TCA, and leads to more incompressible tissue behaviour. STATEMENT OF SIGNIFICANCE: This article analyses and compares for the first time the tension-compression asymmetry (TCA) displayed by skeletal muscle at tissue and fibre scale. In addition, the volume changes of tissue and fibre specimens with application of passive tensile and compressive loads are studied. The study identifies a key role of the extracellular matrix in establishing the mechanical response of skeletal muscle tissue: It contributes significantly to the passive stress, it is responsible for the major part of tissue-scale TCA and, most probably, prevents/balances the volume changes of muscle fibres during deformation. These new results thus shed light on the origin of TCA and provide new information to be used in microstructure-based approaches to model and simulate skeletal muscle tissue.
Collapse
Affiliation(s)
- Markus Böl
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, D-38106 Braunschweig, Germany.
| | - Stephan Kohn
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, D-38106 Braunschweig, Germany
| | - Kay Leichsenring
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, D-38106 Braunschweig, Germany
| | - Enrique Morales-Orcajo
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, D-38106 Braunschweig, Germany
| | - Alexander E Ehret
- Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-8600 Dübendorf, Switzerland; Institute for Mechanical Systems, ETH Zurich, CH-8092, Zürich, Switzerland
| |
Collapse
|
21
|
Stracuzzi A, Britt BR, Mazza E, Ehret AE. Risky interpretations across the length scales: continuum vs. discrete models for soft tissue mechanobiology. Biomech Model Mechanobiol 2022; 21:433-454. [PMID: 34985590 PMCID: PMC8940853 DOI: 10.1007/s10237-021-01543-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 11/28/2021] [Indexed: 11/29/2022]
Abstract
Modelling and simulation in mechanobiology play an increasingly important role to unravel the complex mechanisms that allow resident cells to sense and respond to mechanical cues. Many of the in vivo mechanical loads occur on the tissue length scale, thus raising the essential question how the resulting macroscopic strains and stresses are transferred across the scales down to the cellular and subcellular levels. Since cells anchor to the collagen fibres within the extracellular matrix, the reliable representation of fibre deformation is a prerequisite for models that aim at linking tissue biomechanics and cell mechanobiology. In this paper, we consider the two-scale mechanical response of an affine structural model as an example of a continuum mechanical approach and compare it with the results of a discrete fibre network model. In particular, we shed light on the crucially different mechanical properties of the 'fibres' in these two approaches. While assessing the capability of the affine structural approach to capture the fibre kinematics in real tissues is beyond the scope of our study, our results clearly show that neither the macroscopic tissue response nor the microscopic fibre orientation statistics can clarify the question of affinity.
Collapse
Affiliation(s)
- Alberto Stracuzzi
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600, Dübendorf, Switzerland.
- ETH Zurich, Institute for Mechanical Systems, Leonhardstrasse 21, 8092, Zürich, Switzerland.
| | - Ben R Britt
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600, Dübendorf, Switzerland
- ETH Zurich, Institute for Mechanical Systems, Leonhardstrasse 21, 8092, Zürich, Switzerland
| | - Edoardo Mazza
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600, Dübendorf, Switzerland
- ETH Zurich, Institute for Mechanical Systems, Leonhardstrasse 21, 8092, Zürich, Switzerland
| | - Alexander E Ehret
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600, Dübendorf, Switzerland.
- ETH Zurich, Institute for Mechanical Systems, Leonhardstrasse 21, 8092, Zürich, Switzerland.
| |
Collapse
|
22
|
Orozco GA, Tanska P, Gustafsson A, Korhonen RK, Isaksson H. Crack propagation in articular cartilage under cyclic loading using cohesive finite element modeling. J Mech Behav Biomed Mater 2022; 131:105227. [DOI: 10.1016/j.jmbbm.2022.105227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 03/01/2022] [Accepted: 04/02/2022] [Indexed: 11/28/2022]
|
23
|
Witt NJ, Woessner AE, Quinn KP, Sander EA. Multiscale Computational Model Predicts Mouse Skin Kinematics Under Tensile Loading. J Biomech Eng 2022; 144:041008. [PMID: 34729595 PMCID: PMC8719047 DOI: 10.1115/1.4052887] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 10/11/2021] [Indexed: 11/08/2022]
Abstract
Skin is a complex tissue whose biomechanical properties are generally understood in terms of an incompressible material whose microstructure undergoes affine deformations. A growing number of experiments, however, have demonstrated that skin has a high Poisson's ratio, substantially decreases in volume during uniaxial tensile loading, and demonstrates collagen fiber kinematics that are not affine with local deformation. In order to better understand the mechanical basis for these properties, we constructed multiscale mechanical models (MSM) of mouse skin based on microstructural multiphoton microscopy imaging of the dermal microstructure acquired during mechanical testing. Three models that spanned the cases of highly aligned, moderately aligned, and nearly random fiber networks were examined and compared to the data acquired from uniaxially stretched skin. Our results demonstrate that MSMs consisting of networks of matched fiber organization can predict the biomechanical behavior of mouse skin, including the large decrease in tissue volume and nonaffine fiber kinematics observed under uniaxial tension.
Collapse
Affiliation(s)
- Nathan J. Witt
- Roy J. Carver Department of Biomedical Engineering, College of Engineering, University of Iowa, Iowa City, IA 52242
| | - Alan E. Woessner
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR 72701
| | - Kyle P. Quinn
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, AR 72701
| | - Edward A. Sander
- Roy J. Carver Department of Biomedical Engineering, College of Engineering, University of Iowa, 5629 Seamans Center, Iowa City, IA 52242; Department of Orthopedics and Rehabilitation, Carver College of Medicine, University of Iowa, Iowa City, IA 52242
| |
Collapse
|
24
|
Dwivedi KK, Lakhani P, Kumar S, Kumar N. Effect of collagen fibre orientation on the Poisson's ratio and stress relaxation of skin: an ex vivo and in vivo study. ROYAL SOCIETY OPEN SCIENCE 2022; 9:211301. [PMID: 35345435 PMCID: PMC8941416 DOI: 10.1098/rsos.211301] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Accepted: 01/31/2022] [Indexed: 06/14/2023]
Abstract
During surgical treatment skin undergoes extensive deformation, hence it must be able to withstand large mechanical stresses without damage. Therefore, understanding the mechanical properties of skin becomes important. A detailed investigation on the relationship between the three-dimensional deformation response of skin and its microstructure is conducted in the current study. This study also discloses the underlying science of skin viscoelasticity. Deformation response of skin is captured using digital image correlation, whereas micro-CT, scanning electron microscopy and atomic force microscopy are used for microstructure analysis. Skin shows a large lateral contraction and expansion (auxeticity) when stretched parallel and perpendicular to the skin tension lines, respectively. Large lateral contraction is a result of fluid exudation from the tissue, while large rotation of the stiff collagen fibres in the loading direction explains the skin auxeticity. During stress relaxation, lateral contraction and fluid effluxion from skin reveal that tissue volume loss is the intrinsic science of skin viscoelasticity. Furthermore, the results obtained from in vivo study on human skin show the relevance of the ex vivo study to physiological conditions and stretching of the skin during its treatments.
Collapse
Affiliation(s)
- Krashn Kumar Dwivedi
- Department of Biomedical Engineering, Indian Institute of Technology, Ropar, India
| | - Piyush Lakhani
- Department of Mechanical Engineering, Indian Institute of Technology, Ropar, India
| | - Sachin Kumar
- Department of Mechanical Engineering, Indian Institute of Technology, Ropar, India
| | - Navin Kumar
- Department of Biomedical Engineering, Indian Institute of Technology, Ropar, India
- Department of Mechanical Engineering, Indian Institute of Technology, Ropar, India
| |
Collapse
|
25
|
Morin C, Hellmich C, Nejim Z, Avril S. Fiber Rearrangement and Matrix Compression in Soft Tissues: Multiscale Hypoelasticity and Application to Tendon. Front Bioeng Biotechnol 2021; 9:725047. [PMID: 34712652 PMCID: PMC8546211 DOI: 10.3389/fbioe.2021.725047] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 09/06/2021] [Indexed: 11/13/2022] Open
Abstract
It is widely accepted that the nonlinear macroscopic mechanical behavior of soft tissue is governed by fiber straightening and re-orientation. Here, we provide a quantitative assessment of this phenomenon, by means of a continuum micromechanics approach. Given the negligibly small bending stiffness of crimped fibers, the latter are represented through a number of hypoelastic straight fiber phases with different orientations, being embedded into a hypoelastic matrix phase. The corresponding representative volume element (RVE) hosting these phases is subjected to “macroscopic” strain rates, which are downscaled to fiber and matrix strain rates on the one hand, and to fiber spins on the other hand. This gives quantitative access to the fiber decrimping (or straightening) phenomenon under non-affine conditions, i.e. in the case where the fiber orientations cannot be simply linked to the macroscopic strain state. In the case of tendinous tissue, such an RVE relates to the fascicle material with 50 μm characteristic length, made up of crimped collagen bundles and a gel-type matrix in-between. The fascicles themselves act as parallel fibers in a similar matrix at the scale of a tissue-related RVE with 500 μm characteristic length. As evidenced by a sensitivity analysis and confirmed by various mechanical tests, it is the initial crimping angle which drives both the degree of straightening and the shape of the macroscopic stress-strain curve, while the final linear portion of this curve depends almost exclusively on the collagen bundle elasticity. Our model also reveals the mechanical cooperation of the tissue’s key microstructural components: while the fibers carry tensile forces, the matrices undergo hydrostatic pressure.
Collapse
Affiliation(s)
- Claire Morin
- Mines Saint-Etienne, Univ. Lyon, Univ. Jean Monnet, INSERM, U1059 Sainbiose, Centre CIS, Saint-Etienne, France
| | - Christian Hellmich
- Institute for Mechanics of Materials and Structures, TU Wien - Vienna University of Technology, Vienna, Austria
| | - Zeineb Nejim
- Mines Saint-Etienne, Univ. Lyon, Univ. Jean Monnet, INSERM, U1059 Sainbiose, Centre CIS, Saint-Etienne, France
| | - Stéphane Avril
- Mines Saint-Etienne, Univ. Lyon, Univ. Jean Monnet, INSERM, U1059 Sainbiose, Centre CIS, Saint-Etienne, France.,Institute for Mechanics of Materials and Structures, TU Wien - Vienna University of Technology, Vienna, Austria
| |
Collapse
|
26
|
Rausch MK, Parekh SH, Dortdivanlioglu B, Rosales AM. Synthetic hydrogels as blood clot mimicking wound healing materials. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2021; 3:042006. [PMID: 35822083 PMCID: PMC9273113 DOI: 10.1088/2516-1091/ac23a4] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Excessive bleeding-or hemorrhage-causes millions of civilian and non-civilian casualties every year. Additionally, wound sequelae, such as infections, are a significant source of chronic morbidity, even if the initial bleeding is successfully stopped. To treat acute and chronic wounds, numerous wound healing materials have been identified, tested, and adopted. Among them are topical dressings, such as gauzes, as well as natural and biomimetic materials. However, none of these materials successfully mimic the complex and dynamic properties of the body's own wound healing material: the blood clot. Specifically, blood clots exhibit complex mechanical and biochemical properties that vary across spatial and temporal scales to guide the wound healing response, which make them the ideal wound healing material. In this manuscript, we review blood clots' complex mechanical and biochemical properties, review current wound healing materials, and identify opportunities where new materials can provide additional functionality, with a specific focus on hydrogels. We highlight recent developments in synthetic hydrogels that make them capable of mimicking a larger subset of blood clot features: as plugs and as stimuli for tissue repair. We conclude that future hydrogel materials designed to mimic blood clot biochemistry, mechanics, and architecture can be combined with exciting platelet-like particles to serve as hemostats that also promote the biological wound healing response. Thus, we believe synthetic hydrogels are ideal candidates to address the clear need for better wound healing materials.
Collapse
Affiliation(s)
- Manuel K. Rausch
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX 78712, United States of America
- Department of Aerospace Engineering & Engineering Mechanics, University of Texas at Austin, Austin, TX 78712, United States of America
- Oden Institute for Computational Engineering and Sciences, University of Texas at Austin, Austin, TX 78712, United States of America
| | - Sapun H. Parekh
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX 78712, United States of America
| | - Berkin Dortdivanlioglu
- Oden Institute for Computational Engineering and Sciences, University of Texas at Austin, Austin, TX 78712, United States of America
- Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin, Austin, TX 78712, United States of America
| | - Adrianne M. Rosales
- McKetta Department of Chemical Engineering, University of Texas at Austin, Austin, TX 78712, United States of America
| |
Collapse
|
27
|
Zhao J, Liao D, Wilkens R, Krogh K, Glerup H, Gregersen H. Bowel stiffness associated with histopathologic scoring of stenosis in patients with Crohn's disease. Acta Biomater 2021; 130:332-342. [PMID: 34119715 DOI: 10.1016/j.actbio.2021.06.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 05/31/2021] [Accepted: 06/03/2021] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS Intestinal stenosis is a common complication of Crohn's Disease (CD). Stenosis is associated with alteration of bowel mechanical properties. This study aims to quantitate the mechanical properties of the intestinal stenosis and to explore associations between histology and mechanical remodeling at stenotic intestinal sites in CD patients. METHODS Intestinal segments from stenotic sites were studied in vitro from 19 CD patients. A luminal catheter with a bag was used to stepwise pressurize the intestinal segments from 0-100 cmH2O with 10 cmH2O increments. B-mode ultrasound images were obtained at the narrowest part of the stenosis at each pressure level and morphometric parameters were obtained from ultrasound images. The mechanical behavior of the stenotic tissue were characterized by using an isotropic three dimensional strain energy function in Demiray model form, the mechanical constants were obtained by fitting the model to the recorded intraluminal pressure and the inner radius of the stenotic segment of the small bowel. Grading scores were used for histological analysis of inflammation, fibrosis, muscular hypertrophy and adipocyte proliferation in the intestinal layers. The collagen area fraction in intestinal layers was also calculated. Associations between histological and the mechanical constants (stiffness) were analyzed. RESULTS Chronic inflammation was mainly located in mucosa whereas fibrosis was found in submucosa. The mechanical remodeling was performed with changed mechanical constants ranged between 0.35-13.68kPa. The mechanical properties changes were associated mainly with chronic inflammation, fibrosis and combination of inflammation and fibrosis (R>0.69, P<0.001). Furthermore, the mechanical properties correlated with the collagen fraction in submucosa and muscular layers (R>0.53, P<0.05). CONCLUSIONS We quantitated the intestinal stenosis stiffness. Associations were found between bowel mechanical remodeling and histological changes at the stenotic site in CD patients. STATEMENT OF SIGNIFICANCE Although intestinal ultrasonography, CT and MRI can be used to diagnose Crohn's Disease (CD)-associated bowel strictures, these techniques may not have sufficient accuracy and resolution to differentiate predominantly inflammatory strictures from predominantly fibrotic strictures. The present study aims to quantitate the mechanical remodeling of intestinal stenosis and to explore the associations between histological parameters and mechanical properties at the intestinal stenotic sites in CD patients. For the first time, we quantitatively demonstrated that the mechanical properties of the intestinal wall in CD stenosis are associated with the chronic inflammation, fibrosis and collagen fraction in the intestinal layers. The results of this study may facilitate design and development of artificial biomaterials for gastrointestinal organs. The potential clinical implication of this study is that the histological characteristics in patients with CD can be predicted clinically by means of inflammation and fibrosis assessment in conjunction with tissue stiffness measurement.
Collapse
Affiliation(s)
- Jingbo Zhao
- Standard (Chongqing) Pathological Diagnosis Center. No. 8 Xiyuan North Road, Shapingba District, Chongqing, China; Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital, Denmark; Giome Academia, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Donghua Liao
- Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital, Denmark; Giome Academia, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
| | - Rune Wilkens
- Gastrounit, Division of Medicine, Hvidovre Hospital, University of Copenhagen, Copenhagen, Denmark; Diagnostic Centre, University Research Clinic for Innovative Patient Pathways, Silkeborg Regional Hospital, Silkeborg, Denmark
| | - Klaus Krogh
- Neurogastroenterology Unit, Department of Hepatology and Gastroenterology, Aarhus University Hospital, Aarhus, Denmark
| | - Henning Glerup
- Diagnostic Centre, University Research Clinic for Innovative Patient Pathways, Silkeborg Regional Hospital, Silkeborg, Denmark
| | | |
Collapse
|
28
|
Skin under Strain: From Epithelial Model Tissues to Adult Epithelia. Cells 2021; 10:cells10071834. [PMID: 34360001 PMCID: PMC8304960 DOI: 10.3390/cells10071834] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 07/13/2021] [Accepted: 07/16/2021] [Indexed: 01/14/2023] Open
Abstract
Formation of a barrier capable of protecting tissue from external damage, chemical factors, and pathogens is one of the main functions of the epidermis. Furthermore, upon development and during aging, mechanoprotective epidermal functions change dramatically. However, comparative studies between embryonic and adult skin in comparison to skin equivalents are still scarce which is especially due to the lack of appropriate measurement systems with sufficient accuracy and long-term tissue compatibility. Our studies fill this gap by developing a combined bioreactor and tensile testing machine for biomechanical analysis of living epithelia. Based on this tissue stretcher, our data clearly show that viscoelastic and plastic deformation behavior of embryonic and adult skin differ significantly. Tissue responses to static strain compared to cyclic strain also show a clear dependence on differentiation stage. Multilayered unkeratinized epidermis equivalents, on the other hand, respond very similar to mechanical stretch as adult tissue. This mechanical similarity is even more evident after a single cycle of mechanical preconditioning. Our studies therefore suggest that skin equivalents are well suited model systems to analyze cellular interactions of epidermal cells in natural tissues.
Collapse
|
29
|
Abdollahiyan P, Oroojalian F, Baradaran B, de la Guardia M, Mokhtarzadeh A. Advanced mechanotherapy: Biotensegrity for governing metastatic tumor cell fate via modulating the extracellular matrix. J Control Release 2021; 335:596-618. [PMID: 34097925 DOI: 10.1016/j.jconrel.2021.06.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 06/01/2021] [Accepted: 06/02/2021] [Indexed: 12/19/2022]
Abstract
Mechano-transduction is the procedure of mechanical stimulus translation via cells, among substrate shear flow, topography, and stiffness into a biochemical answer. TAZ and YAP are transcriptional coactivators which are recognized as relay proteins that promote mechano-transduction within the Hippo pathway. With regard to healthy cells in homeostasis, mechano-transduction regularly restricts proliferation, and TAZ and YAP are totally inactive. During cancer development a YAP/TAZ - stimulating positive response loop is formed between the growing tumor and the stiffening ECM. As tumor developments, local stromal and cancerous cells take advantage of mechanotransduction to enhance proliferation, induce their migratory into remote tissues, and promote chemotherapeutic resistance. As a newly progresses paradigm, nanoparticle-conjunctions (such as magnetic nanoparticles, and graphene derivatives nanoparticles) hold significant promises for remote regulation of cells and their relevant events at molecular scale. Despite outstanding developments in employing nanoparticles for drug targeting studies, the role of nanoparticles on cellular behaviors (proliferation, migration, and differentiation) has still required more evaluations in the field of mechanotherapy. In this paper, the in-depth contribution of mechano-transduction is discussed during tumor progression, and how these consequences can be evaluated in vitro.
Collapse
Affiliation(s)
| | - Fatemeh Oroojalian
- Department of Advanced Sciences and Technologies in Medicine, School of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran; Natural Products and Medicinal Plants Research Center, North Khorasan University of Medical Sciences, Bojnurd, Iran.
| | - Behzad Baradaran
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Miguel de la Guardia
- Department of Analytical Chemistry, University of Valencia, Dr. Moliner 50, 46100 Burjassot, Valencia, Spain
| | - Ahad Mokhtarzadeh
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| |
Collapse
|
30
|
McGuire JA, Monclova JL, Coariti ACS, Stine CA, Toussaint KC, Munson JM, Dillard DA, De Vita R. Tear propagation in vaginal tissue under inflation. Acta Biomater 2021; 127:193-204. [PMID: 33831574 PMCID: PMC11832074 DOI: 10.1016/j.actbio.2021.03.065] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 03/06/2021] [Accepted: 03/30/2021] [Indexed: 12/21/2022]
Abstract
Vaginal tearing at childbirth is extremely common yet understudied despite the long-term serious consequences on women's health. The mechanisms of vaginal tearing remain unknown, and their knowledge could lead to the development of transformative prevention and treatment techniques for maternal injury. In this study, whole rat vaginas with pre-imposed elliptical tears oriented along the axial direction of the organs were pressurized using a custom-built inflation setup, producing large tear propagation. Large deformations of tears through propagation were analyzed, and nonlinear strains around tears were calculated using the digital image correlation technique. Second harmonic generation microscopy was used to examine collagen fiber organization in mechanically untested and tested vaginal specimens. Tears became increasingly circular under pressure, propagating slowly up to the maximum pressure and then more rapidly. Hoop strains were significantly larger than axial strains and displayed a region- and orientation-dependent response with tear propagation. Imaging revealed initially disorganized collagen fibers that aligned along the axial direction with increasing pressure. Fibers in the near-regions of tear tips aligned toward the hoop direction, hampering tear propagation. Changes in tear geometry, regional strains, and fiber orientation revealed the inherent toughening mechanisms of the vaginal tissue. STATEMENT OF SIGNIFICANCE: Women's reproductive health has historically been understudied despite alarming maternal injury and mortality rates in the world. Maternal injury and disability can be reduced by advancing our limited understanding of the large deformations experienced by women's reproductive organs. This manuscript presents, for the first time, the mechanics of tear propagation in vaginal tissue and changes to the underlying collagen microstructure near to and far from the tear. A novel inflation setup capable of maintaining the in vivo tubular geometry of the vagina while propagating a pre-imposed tear was developed. Toughening mechanisms of the vagina to propagation were examined through measurements of tear geometry, strain distributions, and reorientation of collagen fibers. This research draws from current advances in the engineering science and mechanics fields with the goal of improving maternal health care.
Collapse
Affiliation(s)
- Jeffrey A McGuire
- STRETCH Lab, Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, United States
| | - Jose L Monclova
- STRETCH Lab, Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, United States
| | | | - Caleb A Stine
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, United States
| | - Kimani C Toussaint
- PROBE Lab, School of Engineering, Brown University, Providence, RI 02912, United States
| | - Jennifer M Munson
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, United States
| | - David A Dillard
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, United States
| | - Raffaella De Vita
- STRETCH Lab, Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, United States.
| |
Collapse
|
31
|
Stracuzzi A, Dittmann J, Böl M, Ehret AE. Visco- and poroelastic contributions of the zona pellucida to the mechanical response of oocytes. Biomech Model Mechanobiol 2021; 20:751-765. [PMID: 33533999 PMCID: PMC7979617 DOI: 10.1007/s10237-020-01414-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Accepted: 12/19/2020] [Indexed: 12/22/2022]
Abstract
Probing mechanical properties of cells has been identified as a means to infer information on their current state, e.g. with respect to diseases or differentiation. Oocytes have gained particular interest, since mechanical parameters are considered potential indicators of the success of in vitro fertilisation procedures. Established tests provide the structural response of the oocyte resulting from the material properties of the cell's components and their disposition. Based on dedicated experiments and numerical simulations, we here provide novel insights on the origin of this response. In particular, polarised light microscopy is used to characterise the anisotropy of the zona pellucida, the outermost layer of the oocyte composed of glycoproteins. This information is combined with data on volumetric changes and the force measured in relaxation/cyclic, compression/indentation experiments to calibrate a multi-phasic hyper-viscoelastic model through inverse finite element analysis. These simulations capture the oocyte's overall force response, the distinct volume changes observed in the zona pellucida, and the structural alterations interpreted as a realignment of the glycoproteins with applied load. The analysis reveals the presence of two distinct timescales, roughly separated by three orders of magnitude, and associated with a rapid outflow of fluid across the external boundaries and a long-term, progressive relaxation of the glycoproteins, respectively. The new results allow breaking the overall response down into the contributions from fluid transport and the mechanical properties of the zona pellucida and ooplasm. In addition to the gain in fundamental knowledge, the outcome of this study may therefore serve an improved interpretation of the data obtained with current methods for mechanical oocyte characterisation.
Collapse
Affiliation(s)
- Alberto Stracuzzi
- Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland
- Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600, Dübendorf, Switzerland
| | - Johannes Dittmann
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, Braunschweig, 38106, Germany
| | - Markus Böl
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, Braunschweig, 38106, Germany.
| | - Alexander E Ehret
- Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland.
- Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600, Dübendorf, Switzerland.
| |
Collapse
|
32
|
Wahlsten A, Rütsche D, Nanni M, Giampietro C, Biedermann T, Reichmann E, Mazza E. Mechanical stimulation induces rapid fibroblast proliferation and accelerates the early maturation of human skin substitutes. Biomaterials 2021; 273:120779. [PMID: 33932701 DOI: 10.1016/j.biomaterials.2021.120779] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 02/28/2021] [Accepted: 03/20/2021] [Indexed: 11/19/2022]
Abstract
The clinical treatment of large, full-thickness skin injuries with tissue-engineered autologous dermo-epidermal skin substitutes is an emerging alternative to split-thickness skin grafting. However, their production requires about one month of in vitro cell and tissue culture, which is a significant drawback for the treatment of patients with severe skin defects. With the aim to reduce the production time, we developed a new dynamic bioreactor setup that applies cyclic biaxial tension to collagen hydrogels for skin tissue engineering. By reliably controlling the time history of mechanical loading, the dynamic culturing results in a three-fold increase in collagen hydrogel stiffness and stimulates the embedded fibroblasts to enter the cell cycle. As a result, the number of fibroblasts is increased by 75% compared to under corresponding static culturing. Enhanced fibroblast proliferation promotes expression of dermal extracellular matrix proteins, keratinocyte proliferation, and the early establishment of the epidermis. The time required for early tissue maturation can therefore be reduced by one week. Analysis of the separate effects of cyclic loading, matrix stiffening, and interstitial fluid flow indicates that cyclic deformation is the dominant biophysical factor determining fibroblast proliferation, while tissue stiffening plays a lesser role. Local differences in the direction of deformation (in-plane equibiaxial vs. uniaxial strain) influence fibroblast orientation but not proliferation, nor the resulting tissue properties. Importantly, dynamic culturing does not activate fibroblast differentiation into myofibroblasts. The present work demonstrates that control of mechanobiological cues can be very effective in driving cell response toward a shorter production time for human skin substitutes.
Collapse
Affiliation(s)
- Adam Wahlsten
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland
| | - Dominic Rütsche
- Tissue Biology Research Unit, Department of Surgery, University Children's Hospital Zurich, Wagistrasse 12, 8952 Schlieren, Switzerland; Children's Research Center, University Children's Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland
| | - Monica Nanni
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland; Tissue Biology Research Unit, Department of Surgery, University Children's Hospital Zurich, Wagistrasse 12, 8952 Schlieren, Switzerland; Children's Research Center, University Children's Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland
| | - Costanza Giampietro
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland
| | - Thomas Biedermann
- Tissue Biology Research Unit, Department of Surgery, University Children's Hospital Zurich, Wagistrasse 12, 8952 Schlieren, Switzerland; Children's Research Center, University Children's Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland
| | - Ernst Reichmann
- Tissue Biology Research Unit, Department of Surgery, University Children's Hospital Zurich, Wagistrasse 12, 8952 Schlieren, Switzerland; Children's Research Center, University Children's Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland.
| | - Edoardo Mazza
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zurich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland.
| |
Collapse
|
33
|
Sachs D, Wahlsten A, Kozerke S, Restivo G, Mazza E. A biphasic multilayer computational model of human skin. Biomech Model Mechanobiol 2021; 20:969-982. [PMID: 33566274 PMCID: PMC8154831 DOI: 10.1007/s10237-021-01424-w] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Accepted: 01/12/2021] [Indexed: 11/26/2022]
Abstract
The present study investigates the layer-specific mechanical behavior of human skin. Motivated by skin’s histology, a biphasic model is proposed which differentiates between epidermis, papillary and reticular dermis, and hypodermis. Inverse analysis of ex vivo tensile and in vivo suction experiments yields mechanical parameters for each layer and predicts a stiff reticular dermis and successively softer papillary dermis, epidermis and hypodermis. Layer-specific analysis of simulations underlines the dominating role of the reticular dermis in tensile loading. Furthermore, it shows that the observed out-of-plane deflection in ex vivo tensile tests is a direct consequence of the layered structure of skin. In in vivo suction experiments, the softer upper layers strongly influence the mechanical response, whose dissipative part is determined by interstitial fluid redistribution within the tissue. Magnetic resonance imaging-based visualization of skin deformation in suction experiments confirms the deformation pattern predicted by the multilayer model, showing a consistent decrease in dermal thickness for large probe opening diameters.
Collapse
Affiliation(s)
- David Sachs
- ETH Zurich, Institute for Mechanical Systems, Zürich, Switzerland
| | - Adam Wahlsten
- ETH Zurich, Institute for Mechanical Systems, Zürich, Switzerland
| | - Sebastian Kozerke
- University and ETH Zurich, Institute for Biomedical Engineering, Zürich, Switzerland
| | - Gaetana Restivo
- Department of Dermatology, University Hospital Zürich, Zürich, Switzerland
| | - Edoardo Mazza
- ETH Zurich, Institute for Mechanical Systems, Zürich, Switzerland
- EMPA, Swiss Federal Laboratories for Materials Science and Technology, Experimental Continuum Mechanics, Dübendorf, Switzerland
| |
Collapse
|
34
|
Predicting muscle tissue response from calibrated component models and histology-based finite element models. J Mech Behav Biomed Mater 2021; 117:104375. [PMID: 33578299 DOI: 10.1016/j.jmbbm.2021.104375] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Revised: 12/21/2020] [Accepted: 01/27/2021] [Indexed: 12/17/2022]
Abstract
Skeletal muscle is an anisotropic soft biological tissue composed of muscle fibres embedded in a structurally complex, hierarchically organised extracellular matrix. In a recent work (Kuravi et al., 2021) we have developed 3D finite element models from series of histological sections. Moreover, based on decellularisation of fresh tissue samples, a novel set of experimental data on the direction dependent mechanical properties of collagenous ECM was established (Kohn et al., 2021). Together with existing information on the material properties of single muscle fibres, the combination of these techniques allows computing predictions of the composite tissue response. To this end, an inverse finite element procedure is proposed in the present work to calibrate a constitutive model of the extracellular matrix, and supplementary biaxial tensile tests on fresh and decellularised tissues are performed for model validation. The results of this rigorously predictive and thus unforgiving strategy suggest that the prediction of the tissue response from the individual characteristics of muscle cells and decellularised tissue is only possible within clear limits. While orders of magnitude are well matched, and the qualitative behaviour in a wide range of load cases is largely captured, the existing deviations point at potentially missing components of the model and highlight the incomplete experimental information in bottom-up multiscale approaches to model skeletal muscle tissue.
Collapse
|
35
|
Sun C, Chernysh IN, Weisel JW, Purohit PK. Fibrous gels modelled as fluid-filled continua with double-well energy landscape. Proc Math Phys Eng Sci 2021; 476:20200643. [PMID: 33408566 DOI: 10.1098/rspa.2020.0643] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2020] [Accepted: 11/11/2020] [Indexed: 01/09/2023] Open
Abstract
Several biological materials are fibre networks infused with fluid, often referred to as fibrous gels. An important feature of these gels is that the fibres buckle under compression, causing a densification of the network that is accompanied by a reduction in volume and release of fluid. Displacement-controlled compression of fibrous gels has shown that the network can exist in a rarefied and a densified state over a range of stresses. Continuum chemo-elastic theories can be used to model the mechanical behaviour of these gels, but they suffer from the drawback that the stored energy function of the underlying network is based on neo-Hookean elasticity, which cannot account for the existence of multiple phases. Here we use a double-well stored energy function in a chemo-elastic model of gels to capture the existence of two phases of the network. We model cyclic compression/decompression experiments on fibrous gels and show that they exhibit propagating interfaces and hysteretic stress-strain curves that have been observed in experiments. We can capture features in the rate-dependent response of these fibrous gels without recourse to finite-element calculations. We also perform experiments to show that certain features in the stress-strain curves of fibrous gels predicted by our model can be found in the compression response of blood clots. Our methods may be extended to other tissues and synthetic gels that have a fibrous structure.
Collapse
Affiliation(s)
- Chuanpeng Sun
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Irina N Chernysh
- Department of Cell and Developmental Biology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - John W Weisel
- Department of Cell and Developmental Biology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Prashant K Purohit
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
36
|
Corroenne R, Yepez M, Barth J, Pan E, Whitehead WE, Espinoza J, Shamshirsaz AA, Nassr AA, Belfort MA, Sanz Cortes M. Chorioamniotic membrane separation following fetal myelomeningocele repair: incidence, risk factors and impact on perinatal outcome. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 56:684-693. [PMID: 31841246 DOI: 10.1002/uog.21947] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 12/02/2019] [Accepted: 12/04/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES Prenatal myelomeningocele (MMC) repair has been shown to provide significant benefits to the infant, decreasing the postnatal need for ventriculoperitoneal shunt and improving motor outcome. Chorioamniotic membrane separation (CAS) is a potential complication following prenatal MMC repair and may increase the risk of preterm prelabor rupture of membranes (PPROM) and preterm birth. The objectives of this study were: (1) to evaluate the incidence of CAS after prenatal MMC repair; (2) to determine risk factors associated with its occurrence; and (3) to assess its association with adverse perinatal outcomes. METHODS This was a retrospective cohort study of patients who underwent fetal MMC repair between November 2011 and December 2018. Surgery was performed using either a fetoscopic (laparotomy or exteriorized uterus) approach or an open-hysterotomy approach. Eligibility criteria were those reported in the Management of Myelomeningocele Study. If CAS was detected on ultrasound (US), its severity was graded as 'mild' if amnion detachment involved < 25% of the uterine cavity, 'moderate' if it involved 25-50% and 'severe' if it involved > 50%. Evolution of CAS was classified as stable, increasing or decreasing based on the difference in severity grading between the time at first diagnosis and the last US scan before delivery. Logistic regression analysis was performed to identify pre- or perisurgical factors associated with the development of CAS and to determine the risk of adverse perinatal outcome associated with CAS. RESULTS In total, 91 cases were included. Fetoscopic or open-hysterotomy repair of MMC was performed in 52/91 (57.1%) and 39/91 (42.9%) cases, at a median gestational age (GA) of 25.0 weeks (range, 22.9-26.0 weeks) and 25.0 weeks (range, 21.3-25.9 weeks), respectively. CAS was diagnosed in 31/91 (34.1%) patients, at a median GA of 28.1 weeks (range, 24.4-37.6 weeks). Anterior placenta was identified as a risk factor for the postoperative development of CAS (odds ratio (OR), 3.72 (95% CI, 1.46-9.5); P < 0.01). This risk was dependent on the repair technique. An anterior placenta significantly increased the risk of CAS after fetoscopic repair (OR, 3.94 (95% CI, 1.14-13.6); P = 0.03) but not after open repair (OR, 2.8 (95% CI, 0.6-12.5); P = 0.16). There was no significant difference in the rate of CAS after fetoscopic repair (21/52 (40.4%)) vs open-hysterotomy repair (10/39 (25.6%)) (P = 0.14), nor were there any differences in GA at diagnosis of CAS, interval between surgery and diagnosis, distribution of CAS severity or progression of CAS between the two groups. CAS increased the risk of PPROM (50% in those with vs 12% in those without CAS) (OR, 7.6 (95% CI, 2.5-21.9); P < 0.01) and preterm delivery (70% vs 38%) (OR, 3.2 (95% CI, 1.3-8.1); P < 0.01). Fetoscopically repaired cases with CAS had a higher rate of PPROM (12/20 (60.0%) vs 2/31 (6.5%); P < 0.01) and preterm delivery (13/20 (65.0%) vs 5/31 (16.1%); P < 0.01) than those that did not develop CAS, while the differences were not significant in cases with open-hysterotomy repair. Early detection of CAS (before 30 weeks' gestation) was a risk factor for preterm delivery (90% before 30 weeks vs 36% at or after 30 weeks) (OR, 15.7 (95% CI, 2.3-106.3); P < 0.01). There was no association between PPROM or preterm delivery and the severity or progression of CAS. CONCLUSIONS The presence of an anterior placenta was the only factor that increased the risk for CAS after fetoscopic MMC repair. Detection of CAS after fetoscopic MMC repair significantly increases the risk for PPROM and preterm delivery. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- R Corroenne
- Department of Obstetrics & Gynecology, Division of Maternal-Fetal Medicine, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| | - M Yepez
- Department of Obstetrics & Gynecology, Division of Maternal-Fetal Medicine, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| | - J Barth
- Department of Obstetrics & Gynecology, Division of Maternal-Fetal Medicine, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| | - E Pan
- Department of Obstetrics & Gynecology, Division of Maternal-Fetal Medicine, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| | - W E Whitehead
- Department of Neurosurgery, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| | - J Espinoza
- Department of Obstetrics & Gynecology, Division of Maternal-Fetal Medicine, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| | - A A Shamshirsaz
- Department of Obstetrics & Gynecology, Division of Maternal-Fetal Medicine, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| | - A A Nassr
- Department of Obstetrics & Gynecology, Division of Maternal-Fetal Medicine, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| | - M A Belfort
- Department of Obstetrics & Gynecology, Division of Maternal-Fetal Medicine, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| | - M Sanz Cortes
- Department of Obstetrics & Gynecology, Division of Maternal-Fetal Medicine, Baylor College of Medicine & Texas Children's Hospital, Houston, TX, USA
| |
Collapse
|
37
|
Tutwiler V, Singh J, Litvinov RI, Bassani JL, Purohit PK, Weisel JW. Rupture of blood clots: Mechanics and pathophysiology. SCIENCE ADVANCES 2020; 6:eabc0496. [PMID: 32923647 PMCID: PMC7449685 DOI: 10.1126/sciadv.abc0496] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 07/02/2020] [Indexed: 05/07/2023]
Abstract
Fibrin is the three-dimensional mechanical scaffold of protective blood clots that stop bleeding and pathological thrombi that obstruct blood vessels. Fibrin must be mechanically tough to withstand rupture, after which life-threatening pieces (thrombotic emboli) are carried downstream by blood flow. Despite multiple studies on fibrin viscoelasticity, mechanisms of fibrin rupture remain unknown. Here, we examined mechanically and structurally the strain-driven rupture of human blood plasma-derived fibrin clots where clotting was triggered with tissue factor. Toughness, i.e., resistance to rupture, quantified by the critical energy release rate (a measure of the propensity for clot embolization) of physiologically relevant fibrin gels was determined to be 7.6 ± 0.45 J/m2. Finite element (FE) simulations using fibrin material models that account for forced protein unfolding independently supported this measured toughness and showed that breaking of fibers ahead the crack at a critical stretch is the mechanism of rupture of blood clots, including thrombotic embolization.
Collapse
Affiliation(s)
- Valerie Tutwiler
- Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, PA, USA
| | - Jaspreet Singh
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA, USA
| | - Rustem I. Litvinov
- Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, PA, USA
- Institute of Fundamental Medicine and Biology, Kazan Federal University, Kazan, Russian Federation
| | - John L. Bassani
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA, USA
| | - Prashant K. Purohit
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA, USA
| | - John W. Weisel
- Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
38
|
Safa BN, Bloom ET, Lee AH, Santare MH, Elliott DM. Evaluation of transverse poroelastic mechanics of tendon using osmotic loading and biphasic mixture finite element modeling. J Biomech 2020; 109:109892. [PMID: 32807341 DOI: 10.1016/j.jbiomech.2020.109892] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 05/15/2020] [Accepted: 06/09/2020] [Indexed: 12/14/2022]
Abstract
Tendon's viscoelastic behaviors are important to the tissue mechanical function and cellular mechanobiology. When loaded in longitudinal tension, tendons often have a large Poisson's ratio (ν>2) that exceeds the limit of incompressibility for isotropic material (ν=0.5), indicating that tendon experiences volume loss, inducing poroelastic fluid exudation in the transverse direction. Therefore, transverse poroelasticity is an important contributor to tendon material behavior. Tendon hydraulic permeability which is required to evaluate the fluid flow contribution to viscoelasticity, is mostly unavailable, and where available, varies by several orders of magnitude. In this manuscript, we quantified the transverse poroelastic material parameters of rat tail tendon fascicles by conducting transverse osmotic loading experiments, in both tension and compression. We used a multi-start optimization method to evaluate the parameters using biphasic finite element modeling. Our tendon samples had a transverse hydraulic permeability of 10-4 to 10-5 mm4. (Ns)-1 and showed a significant tension-compression nonlinearity in the transverse direction. Further, using these results, we predict hydraulic permeability during longitudinal (fiber-aligned) tensile loading, and the spatial distribution of fluid flow during osmotic loading. These results reveal novel aspects of tendon mechanics and can be used to study the physiomechanical response of tendon in response to mechanical loading.
Collapse
Affiliation(s)
- Babak N Safa
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Ellen T Bloom
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Andrea H Lee
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Michael H Santare
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States.
| |
Collapse
|
39
|
Characterization of chemoelastic effects in arteries using digital volume correlation and optical coherence tomography. Acta Biomater 2020; 102:127-137. [PMID: 31794873 DOI: 10.1016/j.actbio.2019.11.049] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 11/25/2019] [Accepted: 11/26/2019] [Indexed: 12/13/2022]
Abstract
Understanding stress-strain relationships in arteries is important for fundamental investigations in mechanobiology. Here we demonstrate the essential role of chemoelasticity in determining the mechanical properties of arterial tissues. Stepwise stress-relaxation uniaxial tensile tests were carried out on samples of porcine thoracic aortas immersed in a hyperosmotic solution. The tissue deformations were tracked using optical coherence tomography (OCT) during the tensile tests and digital volume correlation (DVC) was used to obtain measurements of depth-resolved strains across the whole thickness of the tested aortas. The hyperosmotic solution exacerbated chemoelastic effects, and we were able to measure different manifestations of these chemoelastic effects: swelling of the media inducing a modification of its optical properties, and existence of a transverse tensile strain. For the first time ever to our best knowledge, 3D strains induced by chemoelastic effects in soft tissues were quantified thanks to the OCT-DVC method. Without doubt, chemoelasticity plays an essential role in arterial mechanobiology in vivo and future work should focus on characterizing chemoelastic effects in arterial walls under physiological and disease conditions. STATEMENT OF SIGNIFICANCE: Chemoelasticity, coupling osmotic phenomena and mechanical stresses, is essential in soft tissue mechanobiology. For the first time ever, we measure and analyze 3D strain fields induced by these chemoelastic effects thanks to the unique combination of OCT imaging and digital volume correlation.
Collapse
|
40
|
Ferruzzi J, Zhang Y, Roblyer D, Zaman MH. Multi-scale Mechanics of Collagen Networks: Biomechanical Basis of Matrix Remodeling in Cancer. MULTI-SCALE EXTRACELLULAR MATRIX MECHANICS AND MECHANOBIOLOGY 2020. [DOI: 10.1007/978-3-030-20182-1_11] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
41
|
Cavinato C, Badel P, Krasny W, Avril S, Morin C. Experimental Characterization of Adventitial Collagen Fiber Kinematics Using Second-Harmonic Generation Imaging Microscopy: Similarities and Differences Across Arteries, Species and Testing Conditions. MULTI-SCALE EXTRACELLULAR MATRIX MECHANICS AND MECHANOBIOLOGY 2020. [DOI: 10.1007/978-3-030-20182-1_5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
42
|
Compressive Remodeling Alters Fluid Transport Properties of Collagen Networks - Implications for Tumor Growth. Sci Rep 2019; 9:17151. [PMID: 31748563 PMCID: PMC6868165 DOI: 10.1038/s41598-019-50268-z] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 09/08/2019] [Indexed: 12/27/2022] Open
Abstract
Biomechanical alterations to the tumor microenvironment include accumulation of solid stresses, extracellular matrix (ECM) stiffening and increased fluid pressure in both interstitial and peri-tumoral spaces. The relationship between interstitial fluid pressurization and ECM remodeling in vascularized tumors is well characterized, while earlier biomechanical changes occurring during avascular tumor growth within the peri-tumoral ECM remain poorly understood. Type I collagen, the primary fibrous ECM constituent, bears load in tension while it buckles under compression. We hypothesized that tumor-generated compressive forces cause collagen remodeling via densification which in turn creates a barrier to convective fluid transport and may play a role in tumor progression and malignancy. To better understand this process, we characterized the structure-function relationship of collagen networks under compression both experimentally and computationally. Here we show that growth of epithelial cancers induces compressive remodeling of the ECM, documented in the literature as a TACS-2 phenotype, which represents a localized densification and tangential alignment of peri-tumoral collagen. Such compressive remodeling is caused by the unique features of collagen network mechanics, such as fiber buckling and cross-link rupture, and reduces the overall hydraulic permeability of the matrix.
Collapse
|
43
|
Domaschke S, Morel A, Fortunato G, Ehret AE. Random auxetics from buckling fibre networks. Nat Commun 2019; 10:4863. [PMID: 31653833 PMCID: PMC6961253 DOI: 10.1038/s41467-019-12757-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Accepted: 09/24/2019] [Indexed: 11/21/2022] Open
Abstract
Auxetic materials have gained increasing interest in the last decades, fostered by auspicious applications in various fields. While the design of new auxetics has largely focused on meta-materials with deterministic, periodically arranged structures, we show here by theoretical and numerical analysis that pronounced auxetic behaviour with negative Poisson's ratios of very large magnitude can occur in random fibre networks with slender, reasonably straight fibre segments that buckle and deflect. We further demonstrate in experiments that such auxetic fibre networks, which increase their thickness by an order of magnitude and more than quintuple their volume when moderately extended, can be produced by electrospinning. Our results thus augment the class of auxetics by a large group of straightforwardly fabricable meta-materials with stochastic microstructure.
Collapse
Affiliation(s)
- S Domaschke
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Experimental Continuum Mechanics, 8600, Dübendorf, Switzerland
- ETH Zurich, Institute for Mechanical Systems, 8092, Zürich, Switzerland
| | - A Morel
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, 9014, St. Gallen, Switzerland
| | - G Fortunato
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, 9014, St. Gallen, Switzerland
| | - A E Ehret
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Experimental Continuum Mechanics, 8600, Dübendorf, Switzerland.
- ETH Zurich, Institute for Mechanical Systems, 8092, Zürich, Switzerland.
| |
Collapse
|
44
|
Bircher K, Merluzzi R, Wahlsten A, Spiess D, Simões-Wüst AP, Ochsenbein-Kölble N, Zimmermann R, Deprest J, Mazza E. Influence of osmolarity and hydration on the tear resistance of the human amniotic membrane. J Biomech 2019; 98:109419. [PMID: 31679754 DOI: 10.1016/j.jbiomech.2019.109419] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Revised: 08/15/2019] [Accepted: 10/13/2019] [Indexed: 12/20/2022]
Abstract
The amnion is considered to be the load-bearing part of the fetal membranes. We investigated the influence of osmolarity of the testing medium and hydration on its fracture toughness. Mode I fracture tests revealed that physiological variations in the bath osmolarity do not influence the tear resistance of amnion, while larger changes, i.e. from physiological saline solution to distilled water, lead to a significant reduction of the fracture toughness. Uniaxial tensile tests on collagen hydrogels confirmed the reduction in toughness, suggesting that lower bath osmolarity triggers changes in the failure properties of single collagen fibers. Prenatal surgeries, in particular fetoscopic procedures with partial amniotic carbon dioxide insufflation, might result in dehydration of the amnion. Dehydration induced a brittle behavior; however, subsequent rehydration for 15 min resulted in a similar tear resistance as for the fresh tissue.
Collapse
Affiliation(s)
- Kevin Bircher
- ETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland
| | - Riccardo Merluzzi
- ETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland
| | - Adam Wahlsten
- ETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland
| | - Deborah Spiess
- University Hospital Zurich, Department of Obstetrics, 8091 Zurich, Switzerland
| | | | | | - Roland Zimmermann
- University Hospital Zurich, Department of Obstetrics, 8091 Zurich, Switzerland
| | - Jan Deprest
- University Hospitals Leuven, Department of Obstetrics and Gynecology, 3000 Leuven, Belgium; Institute of Women's Health, Research Department of Maternal Fetal Medicine, University College London, London, UK
| | - Edoardo Mazza
- ETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600 Dübendorf, Switzerland.
| |
Collapse
|
45
|
Ronsin O, Naassaoui I, Marcellan A, Baumberger T. Environmental Nanoparticle-Induced Toughening and Pinning of a Growing Crack in a Biopolymer Hydrogel. PHYSICAL REVIEW LETTERS 2019; 123:158002. [PMID: 31702313 DOI: 10.1103/physrevlett.123.158002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Indexed: 06/10/2023]
Abstract
We study the interplay between a crack tip slowly propagating through a hydrogel and nanoparticles suspended in its liquid environment. Using a proteinic gel enables us to tune the electrostatic interaction between the network and silica colloids. Thereby, we unveil two distinct, local toughening mechanisms. The primary one is charge independent and involves the convective building of a thin particulate clog, hindering polymer hydration in the crack process zone. When particles and network bear opposite charges, transient adhesive bonding superimposes, permitting the remarkable pinning of a crack by a liquid drop.
Collapse
Affiliation(s)
- O Ronsin
- Institut des NanoSciences de Paris, Sorbonne University, CNRS, F-75005 Paris, France
| | - I Naassaoui
- Institut des NanoSciences de Paris, Sorbonne University, CNRS, F-75005 Paris, France
- Laboratoire de Physique de la Matière Molle et de la Modélisation Électromagnétique, Université de Tunis, El Manar, 2092 Tunis, Tunisia
| | - A Marcellan
- Laboratoire Sciences et Ingénierie de la Matière Molle, ESPCI Paris, PSL University, Sorbonne University, CNRS, F-75005 Paris, France
| | - T Baumberger
- Institut des NanoSciences de Paris, Sorbonne University, CNRS, F-75005 Paris, France
| |
Collapse
|
46
|
Solav D, Moerman KM, Jaeger AM, Herr HM. A Framework for Measuring the Time-Varying Shape and Full-Field Deformation of Residual Limbs Using 3-D Digital Image Correlation. IEEE Trans Biomed Eng 2019; 66:2740-2752. [PMID: 30676943 PMCID: PMC6783393 DOI: 10.1109/tbme.2019.2895283] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Effective prosthetic socket design following lower limb amputation depends upon the accurate characterization of the shape of the residual limb as well as its volume and shape fluctuations. OBJECTIVE This study proposes a novel framework for the measurement and analysis of residual limb shape and deformation, using a high-resolution and low-cost system. METHODS A multi-camera system was designed to capture sets of simultaneous images of the entire residuum surface. The images were analyzed using a specially developed open-source three-dimensional digital image correlation (3D-DIC) toolbox, to obtain the accurate time-varying shapes as well as the full-field deformation and strain maps on the residuum skin surface. Measurements on a transtibial amputee residuum were obtained during knee flexions, muscle contractions, and swelling upon socket removal. RESULTS It was demonstrated that 3D-DIC can be employed to quantify with high resolution time-varying residuum shapes, deformations, and strains. Additionally, the enclosed volumes and cross-sectional areas were computed and analyzed. CONCLUSION This novel low-cost framework provides a promising solution for the in vivo evaluation of residuum shapes and strains, as well as has the potential for characterizing the mechanical properties of the underlying soft tissues. SIGNIFICANCE These data may be used to inform data-driven computational algorithms for the design of prosthetic sockets, as well as of other wearable technologies mechanically interfacing with the skin.
Collapse
|
47
|
Bircher K, Ehret AE, Spiess D, Ehrbar M, Simões-Wüst AP, Ochsenbein-Kölble N, Zimmermann R, Mazza E. On the defect tolerance of fetal membranes. Interface Focus 2019; 9:20190010. [PMID: 31485307 DOI: 10.1098/rsfs.2019.0010] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/15/2019] [Indexed: 11/12/2022] Open
Abstract
A series of mechanical experiments were performed to quantify the strength and fracture toughness of human amnion and chorion. The experiments were complemented with computational investigations using a 'hybrid' model that includes an explicit representation of the collagen fibre network of amnion. Despite its much smaller thickness, amnion is shown to be stiffer, stronger and tougher than chorion, and thus to determine the mechanical response of fetal membranes, with respect to both, deformation and fracture behaviour. Data from uniaxial tension and fracture tests were used to inform and validate the computational model, which was then applied to rationalize measurements of the tear resistance of tissue samples containing crack-like defects. Experiments and computations show that the strength of amnion is not significantly reduced by defects smaller than 1 mm, but the crack size induced by perforations for amniocentesis and fetal membrane suturing during fetal surgery might be larger than this value. In line with previous experimental observations, the computational model predicts a very narrow near field at the crack tip of amnion, due to localized fibre alignment and collagen compaction. This mechanism shields the tissue from the defect and strongly reduces the interaction of multiple adjacent cracks. These findings were confirmed through corresponding experiments, showing that no interaction is expected for multiple sutures for an inter-suture distance larger than 1 mm and 3 mm for amnion and chorion, respectively. The experimental procedures and numerical models applied in the present study might be used to optimize needle and/or staple dimensions and inter-suture distance, and thus to reduce the risk of iatrogenic preterm premature rupture of the membranes from amniocentesis, fetoscopic and open prenatal surgery.
Collapse
Affiliation(s)
- Kevin Bircher
- ETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland
| | - Alexander E Ehret
- ETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland.,Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600 Dübendorf, Switzerland
| | - Deborah Spiess
- Department of Obstetrics, University Hospital Zurich, 8091 Zurich, Switzerland
| | - Martin Ehrbar
- Department of Obstetrics, University Hospital Zurich, 8091 Zurich, Switzerland
| | | | | | - Roland Zimmermann
- Department of Obstetrics, University Hospital Zurich, 8091 Zurich, Switzerland
| | - Edoardo Mazza
- ETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland.,Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600 Dübendorf, Switzerland
| |
Collapse
|
48
|
Towards Patient-Specific Computational Modelling of Articular Cartilage on the Basis of Advanced Multiparametric MRI Techniques. Sci Rep 2019; 9:7172. [PMID: 31073178 PMCID: PMC6509121 DOI: 10.1038/s41598-019-43389-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Accepted: 04/23/2019] [Indexed: 12/13/2022] Open
Abstract
Cartilage degeneration is associated with tissue softening and represents the hallmark change of osteoarthritis. Advanced quantitative Magnetic Resonance Imaging (qMRI) techniques allow the assessment of subtle tissue changes not only of structure and morphology but also of composition. Yet, the relation between qMRI parameters on the one hand and microstructure, composition and the resulting functional tissue properties on the other hand remain to be defined. To this end, a Finite-Element framework was developed based on an anisotropic constitutive model of cartilage informed by sample-specific multiparametric qMRI maps, obtained for eight osteochondral samples on a clinical 3.0 T MRI scanner. For reference, the same samples were subjected to confined compression tests to evaluate stiffness and compressibility. Moreover, the Mankin score as an indicator of histological tissue degeneration was determined. The constitutive model was optimized against the resulting stress responses and informed solely by the sample-specific qMRI parameter maps. Thereby, the biomechanical properties of individual samples could be captured with good-to-excellent accuracy (mean R2 [square of Pearson's correlation coefficient]: 0.966, range [min, max]: 0.904, 0.993; mean Ω [relative approximated error]: 33%, range [min, max]: 20%, 47%). Thus, advanced qMRI techniques may be complemented by the developed computational model of cartilage to comprehensively evaluate the functional dimension of non-invasively obtained imaging biomarkers. Thereby, cartilage degeneration can be perspectively evaluated in the context of imaging and biomechanics.
Collapse
|
49
|
Wahlsten A, Pensalfini M, Stracuzzi A, Restivo G, Hopf R, Mazza E. On the compressibility and poroelasticity of human and murine skin. Biomech Model Mechanobiol 2019; 18:1079-1093. [PMID: 30806838 DOI: 10.1007/s10237-019-01129-1] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Accepted: 02/09/2019] [Indexed: 01/09/2023]
Abstract
A total of 37 human and 33 murine skin samples were subjected to uniaxial monotonic, cyclic, and relaxation experiments. Detailed analysis of the three-dimensional kinematic response showed that skin volume is significantly reduced as a consequence of a tensile elongation. This behavior is most pronounced in monotonic but persists in cyclic tests. The dehydration associated with volume loss depends on the osmolarity of the environment, so that tension relaxation changes as a consequence of modifying the ionic strength of the environmental bath. Similar to ex vivo observations, complementary in vivo stretching experiments on human volar forearms showed strong in-plane lateral contraction. A biphasic homogenized model is proposed which allows representing all relevant features of the observed mechanical response.
Collapse
Affiliation(s)
- Adam Wahlsten
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland.
| | - Marco Pensalfini
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland
| | - Alberto Stracuzzi
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland
| | - Gaetana Restivo
- Department of Dermatology, University Hospital Zurich, 8091, Zurich, Switzerland
| | - Raoul Hopf
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland.,Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600, Dübendorf, Switzerland
| | - Edoardo Mazza
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland. .,Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600, Dübendorf, Switzerland.
| |
Collapse
|
50
|
Abstract
Fracture toughness characterizes the ability of a material to maintain a certain level of strength despite the presence of a macroscopic crack. Understanding this tolerance for defects in soft collagenous tissues (SCT) has high relevance for assessing the risks of fracture after cutting, perforation or suturing. Here we investigate the peculiar toughening mechanisms of SCT through dedicated experiments and multi-scale simulations, showing that classical concepts of fracture mechanics are inadequate to quantify and explain the high defect tolerance of these materials. Our results demonstrate that SCT strength is only modestly reduced by defects as large as several millimeters. This defect tolerance is achieved despite a very narrow process zone at the crack tip and even for a network of brittle fibrils. The fracture mechanics concept of tearing energy fails in predicting failure at such defects, and its magnitude is shown to depend on the chemical potential of the liquid environment.
Collapse
|