1
|
Lou C, Yang H, Hou Y, Huang H, Qiu J, Wang C, Sang Y, Liu H, Han L. Microfluidic Platforms for Real-Time In Situ Monitoring of Biomarkers for Cellular Processes. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307051. [PMID: 37844125 DOI: 10.1002/adma.202307051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/05/2023] [Indexed: 10/18/2023]
Abstract
Cellular processes are mechanisms carried out at the cellular level that are aimed at guaranteeing the stability of the organism they comprise. The investigation of cellular processes is key to understanding cell fate, understanding pathogenic mechanisms, and developing new therapeutic technologies. Microfluidic platforms are thought to be the most powerful tools among all methodologies for investigating cellular processes because they can integrate almost all types of the existing intracellular and extracellular biomarker-sensing methods and observation approaches for cell behavior, combined with precisely controlled cell culture, manipulation, stimulation, and analysis. Most importantly, microfluidic platforms can realize real-time in situ detection of secreted proteins, exosomes, and other biomarkers produced during cell physiological processes, thereby providing the possibility to draw the whole picture for a cellular process. Owing to their advantages of high throughput, low sample consumption, and precise cell control, microfluidic platforms with real-time in situ monitoring characteristics are widely being used in cell analysis, disease diagnosis, pharmaceutical research, and biological production. This review focuses on the basic concepts, recent progress, and application prospects of microfluidic platforms for real-time in situ monitoring of biomarkers in cellular processes.
Collapse
Affiliation(s)
- Chengming Lou
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Hongru Yang
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Ying Hou
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Haina Huang
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Jichuan Qiu
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Chunhua Wang
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Yuanhua Sang
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
| | - Hong Liu
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, 250100, P. R. China
- Institute for Advanced Interdisciplinary Research (IAIR), University of Jinan, Jinan, 250022, P. R. China
| | - Lin Han
- Institute of Marine Science and Technology, Shandong University, Qingdao, Shandong, 266000, P. R. China
| |
Collapse
|
2
|
Peng AY, Lee BE. Microphysiological Systems for Cancer Immunotherapy Research and Development. Adv Biol (Weinh) 2023:e2300077. [PMID: 37409385 PMCID: PMC10770294 DOI: 10.1002/adbi.202300077] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 06/13/2023] [Indexed: 07/07/2023]
Abstract
Cancer immunotherapy focuses on the use of patients' adaptive immune systems to combat cancer. In the past decade, FDA has approved many immunotherapy products for cancer patients who suffer from primary tumors, tumor relapse, and metastases. However, these immunotherapies still show resistance in many patients and often lead to inconsistent responses in patients due to variations in tumor genetic mutations and tumor immune microenvironment. Microfluidics-based organ-on-a-chip technologies or microphysiological systems have opened new ways that can provide relatively fast screening for personalized immunotherapy and help researchers and clinicians understand tumor-immune interactions in a patient-specific manner. They also have the potential to overcome the limitations of traditional drug screening and testing, given the models provide a more realistic 3D microenvironment with better controllability, reproducibility, and physiological relevance. This review focuses on the cutting-edge microphysiological organ-on-a-chip devices developed in recent years for studying cancer immunity and testing cancer immunotherapeutic agents, as well as some of the largest challenges of translating this technology to clinical applications in immunotherapy and personalized medicine.
Collapse
Affiliation(s)
- A. Yansong Peng
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, USA
| | - B. Esak Lee
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, USA
| |
Collapse
|
3
|
Recent advances for cancer detection and treatment by microfluidic technology, review and update. Biol Proced Online 2022; 24:5. [PMID: 35484481 PMCID: PMC9052508 DOI: 10.1186/s12575-022-00166-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 04/18/2022] [Indexed: 12/16/2022] Open
Abstract
Numerous cancer-associated deaths are owing to a lack of effective diagnostic and therapeutic approaches. Microfluidic systems for analyzing a low volume of samples offer a precise, quick, and user-friendly technique for cancer diagnosis and treatment. Microfluidic devices can detect many cancer-diagnostic factors from biological fluids and also generate appropriate nanoparticles for drug delivery. Thus, microfluidics may be valuable in the cancer field due to its high sensitivity, high throughput, and low cost. In the present article, we aim to review recent achievements in the application of microfluidic systems for the diagnosis and treatment of various cancers. Although microfluidic platforms are not yet used in the clinic, they are expected to become the main technology for cancer diagnosis and treatment. Microfluidic systems are proving to be more sensitive and accurate for the detection of cancer biomarkers and therapeutic strategies than common assays. Microfluidic lab-on-a-chip platforms have shown remarkable potential in the designing of novel procedures for cancer detection, therapy, and disease follow-up as well as the development of new drug delivery systems for cancer treatment.
Collapse
|
4
|
Xie H, Ding X. The Intriguing Landscape of Single-Cell Protein Analysis. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2105932. [PMID: 35199955 PMCID: PMC9036017 DOI: 10.1002/advs.202105932] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 01/27/2022] [Indexed: 05/15/2023]
Abstract
Profiling protein expression at single-cell resolution is essential for fundamental biological research (such as cell differentiation and tumor microenvironmental examination) and clinical precision medicine where only a limited number of primary cells are permitted. With the recent advances in engineering, chemistry, and biology, single-cell protein analysis methods are developed rapidly, which enable high-throughput and multiplexed protein measurements in thousands of individual cells. In combination with single cell RNA sequencing and mass spectrometry, single-cell multi-omics analysis can simultaneously measure multiple modalities including mRNAs, proteins, and metabolites in single cells, and obtain a more comprehensive exploration of cellular signaling processes, such as DNA modifications, chromatin accessibility, protein abundance, and gene perturbation. Here, the recent progress and applications of single-cell protein analysis technologies in the last decade are summarized. Current limitations, challenges, and possible future directions in this field are also discussed.
Collapse
Affiliation(s)
- Haiyang Xie
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong UniversityShanghai200030China
| | - Xianting Ding
- State Key Laboratory of Oncogenes and Related GenesInstitute for Personalized MedicineSchool of Biomedical EngineeringShanghai Jiao Tong UniversityShanghai200030China
| |
Collapse
|
5
|
Manzoor AA, Hwang DK. Modeling and Numerical Studies of Three‐Dimensional Conically Shaped Microwells Using Non‐Uniform Photolithography. MACROMOL THEOR SIMUL 2022. [DOI: 10.1002/mats.202100085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Ahmad Ali Manzoor
- Department of Chemical Engineering Ryerson University 350 Victoria Street Toronto ON M5B 2K3 Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital 30 Bond Street Toronto ON M5B 1W8 Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST) A Partnership Between Ryerson University and St. Michael's Hospital 30 Bond Street Toronto ON M5B 1W8 Canada
| | - Dae Kun Hwang
- Department of Chemical Engineering Ryerson University 350 Victoria Street Toronto ON M5B 2K3 Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital 30 Bond Street Toronto ON M5B 1W8 Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST) A Partnership Between Ryerson University and St. Michael's Hospital 30 Bond Street Toronto ON M5B 1W8 Canada
| |
Collapse
|
6
|
Abadpour S, Aizenshtadt A, Olsen PA, Shoji K, Wilson SR, Krauss S, Scholz H. Pancreas-on-a-Chip Technology for Transplantation Applications. Curr Diab Rep 2020; 20:72. [PMID: 33206261 PMCID: PMC7674381 DOI: 10.1007/s11892-020-01357-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/26/2020] [Indexed: 02/07/2023]
Abstract
PURPOSE OF REVIEW Human pancreas-on-a-chip (PoC) technology is quickly advancing as a platform for complex in vitro modeling of islet physiology. This review summarizes the current progress and evaluates the possibility of using this technology for clinical islet transplantation. RECENT FINDINGS PoC microfluidic platforms have mainly shown proof of principle for long-term culturing of islets to study islet function in a standardized format. Advancement in microfluidic design by using imaging-compatible biomaterials and biosensor technology might provide a novel future tool for predicting islet transplantation outcome. Progress in combining islets with other tissue types gives a possibility to study diabetic interventions in a minimal equivalent in vitro environment. Although the field of PoC is still in its infancy, considerable progress in the development of functional systems has brought the technology on the verge of a general applicable tool that may be used to study islet quality and to replace animal testing in the development of diabetes interventions.
Collapse
Affiliation(s)
- Shadab Abadpour
- Department of Transplant Medicine and Institute for Surgical Research, Oslo University Hospital, Post Box 4950, Nydalen, N-0424 Oslo, Norway
- Hybrid Technology Hub-Centre of Excellence, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| | - Aleksandra Aizenshtadt
- Hybrid Technology Hub-Centre of Excellence, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| | - Petter Angell Olsen
- Hybrid Technology Hub-Centre of Excellence, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| | - Kayoko Shoji
- Hybrid Technology Hub-Centre of Excellence, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| | - Steven Ray Wilson
- Hybrid Technology Hub-Centre of Excellence, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
- Department of Chemistry, University of Oslo, Oslo, Norway
| | - Stefan Krauss
- Hybrid Technology Hub-Centre of Excellence, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
- Institute of Immunology, Oslo University Hospital, Oslo, Norway
| | - Hanne Scholz
- Department of Transplant Medicine and Institute for Surgical Research, Oslo University Hospital, Post Box 4950, Nydalen, N-0424 Oslo, Norway
- Hybrid Technology Hub-Centre of Excellence, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
| |
Collapse
|
7
|
Liu L, Hu D, Lam RHW. Microfluidic Viscometer Using a Suspending Micromembrane for Measurement of Biosamples. MICROMACHINES 2020; 11:mi11100934. [PMID: 33066536 PMCID: PMC7602240 DOI: 10.3390/mi11100934] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 10/13/2020] [Accepted: 10/13/2020] [Indexed: 01/26/2023]
Abstract
The viscosity of biofluids such as blood and saliva can reflect an individual’s health conditions, and viscosity measurements are therefore considered in health monitoring and disease diagnosis. However, conventional viscometers can only handle a larger liquid volume beyond the quantity that can be extracted from a person. Though very effective, micro-sensors based on electrokinetic, ultrasonic, or other principles often have strict requirements for the supporting equipment and complicated procedures and signal processing. Sample contamination is always an important issue. In this paper, we report a microfluidic viscometer requiring a small volume of biosamples (<50 µL) and straightforward operation procedures. It is fabricated with low-cost and biocompatible polymeric materials as one-time-use devices, such that contamination is no longer the concern. It contains a suspending micromembrane located along a microchannel. Under a steady driving pressure, the membrane displacement is a function of viscosity of the liquid sample being tested. We derived a simple analytical relation and perform a simulation for converting the membrane displacement to the sample viscosity. We conducted experiments with liquids (water and mineral oil) with defined properties to verify such a relation. We further applied the micro-viscometer to measure bovine blood samples with different hematocrit levels. It can be concluded that the microfluidic viscometer has a high compatibility with a broad range of biomedical applications.
Collapse
Affiliation(s)
- Lelin Liu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China; (L.L.); (D.H.)
| | - Dinglong Hu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China; (L.L.); (D.H.)
- Institute of Biointelligence Technology, BGI-Shenzhen, Shenzhen 518083, China
| | - Raymond H. W. Lam
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China; (L.L.); (D.H.)
- City University of Hong Kong Shenzhen Research Institute, Shenzhen 518057, China
- Centre for Biosystems, Neuroscience, and Nanotechnology, City University of Hong Kong, Hong Kong, China
- Centre for Robotics and Automation, City University of Hong Kong, Hong Kong, China
- Correspondence: ; Tel.: +852-3442-8577
| |
Collapse
|
8
|
Manzoor AA, Romita L, Hwang DK. A review on microwell and microfluidic geometric array fabrication techniques and its potential applications in cellular studies. CAN J CHEM ENG 2020. [DOI: 10.1002/cjce.23875] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Ahmad Ali Manzoor
- Department of Chemical Engineering Ryerson University Toronto Ontario Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital Toronto Ontario Canada
- Institute for Biomedical Engineering Science and Technology (iBEST) A partnership between Ryerson University and St. Michael's Hospital Toronto Ontario Canada
| | - Lauren Romita
- Department of Chemical Engineering Ryerson University Toronto Ontario Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital Toronto Ontario Canada
- Institute for Biomedical Engineering Science and Technology (iBEST) A partnership between Ryerson University and St. Michael's Hospital Toronto Ontario Canada
| | - Dae Kun Hwang
- Department of Chemical Engineering Ryerson University Toronto Ontario Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital Toronto Ontario Canada
- Institute for Biomedical Engineering Science and Technology (iBEST) A partnership between Ryerson University and St. Michael's Hospital Toronto Ontario Canada
| |
Collapse
|
9
|
Rodriguez-Moncayo R, Jimenez-Valdes RJ, Gonzalez-Suarez AM, Garcia-Cordero JL. Integrated Microfluidic Device for Functional Secretory Immunophenotyping of Immune Cells. ACS Sens 2020; 5:353-361. [PMID: 31927915 DOI: 10.1021/acssensors.9b01786] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Integrated platforms for automatic assessment of cellular functional secretory immunophenotyping could have a widespread use in the diagnosis, real-time monitoring, and therapy evaluation of several pathologies. We present a microfluidic platform with integrated biosensors and culture chambers to measure cytokine secretion from a consistent and uniform number of immune cells. The biosensor relies on a fluorescence sandwich immunoassay enabled by the mechanically induced trapping of molecular interactions method. The platform contains 32 cell culture chambers, each patterned with an array of 492 microwells, to capture and analyze both adherent and nonadherent immune cells. Multiple stimuli can be delivered to a set of culture chambers. Per chamber, we were able to capture consistently 1113 ± 191 of blood-derived monocytes and neutrophils and 348 ± 37 THP-1 monocytes. Good occupancy efficiencies of ∼70% with a uniformity of ∼90% across all of the culture chambers of the device were achieved. Furthermore, we demonstrate that up to 96% of cells remain viable for the first 48 h. The employment of epoxy-modified glass substrates and active mixing enhanced the biosensing performance compared to the use of bare glass and simple diffusion. Finally, we performed functional secretory analysis of interleukin-8 and tumor necrosis factor alpha from human neutrophils and monocytes, stimulated with various doses of lipopolysaccharide and phorbol 12-myristate 13-acetate-ionomycin, respectively. We foresee the employment of our microfluidic platform in the diagnosis of different pathologies where alterations in cytokine secretion patterns can be used as biomarkers.
Collapse
Affiliation(s)
- Roberto Rodriguez-Moncayo
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Parque PIIT, Apodaca, Nuevo León 66628, Mexico
| | - Rocio Jimena Jimenez-Valdes
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Parque PIIT, Apodaca, Nuevo León 66628, Mexico
| | - Alan Mauricio Gonzalez-Suarez
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Parque PIIT, Apodaca, Nuevo León 66628, Mexico
| | - Jose Luis Garcia-Cordero
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Parque PIIT, Apodaca, Nuevo León 66628, Mexico
| |
Collapse
|
10
|
Liu R, Chu CH, Wang N, Ozkaya-Ahmadov T, Civelekoglu O, Lee D, Arifuzzman AKM, Sarioglu AF. Combinatorial Immunophenotyping of Cell Populations with an Electronic Antibody Microarray. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1904732. [PMID: 31631578 DOI: 10.1002/smll.201904732] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 10/05/2019] [Indexed: 06/10/2023]
Abstract
Immunophenotyping is widely used to characterize cell populations in basic research and to diagnose diseases from surface biomarkers in the clinic. This process usually requires complex instruments such as flow cytometers or fluorescence microscopes, which are typically housed in centralized laboratories. Microfluidics are combined with an integrated electrical sensor network to create an antibody microarray for label-free cell immunophenotyping against multiple antigens. The device works by fractionating the sample via capturing target subpopulations in an array of microfluidic chambers functionalized against different antigens and by electrically quantifying the cell capture statistics through a network of code-multiplexed electrical sensors. Through a combinatorial arrangement of antibody sequences along different microfluidic paths, the device can measure the prevalence of different cell subpopulations in a sample from computational analysis of the electrical output signal. The device performance is characterized by analyzing heterogeneous samples of mixed tumor cell populations and then the technique is applied to determine leukocyte subpopulations in blood samples and the results are validated against complete blood cell count and flow cytometry results. Label-free immunophenotyping of cell populations against multiple targets on a disposable electronic chip presents opportunities in global health and telemedicine applications for cell-based diagnostics and health monitoring.
Collapse
Affiliation(s)
- Ruxiu Liu
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Chia-Heng Chu
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Ningquan Wang
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Tevhide Ozkaya-Ahmadov
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Ozgun Civelekoglu
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Dohwan Lee
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - A K M Arifuzzman
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - A Fatih Sarioglu
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| |
Collapse
|
11
|
Jiang L, Ivich F, Tahsin S, Tran M, Frank SB, Miranti CK, Zohar Y. Human stroma and epithelium co-culture in a microfluidic model of a human prostate gland. BIOMICROFLUIDICS 2019; 13:064116. [PMID: 31768202 PMCID: PMC6867939 DOI: 10.1063/1.5126714] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Accepted: 11/11/2019] [Indexed: 05/10/2023]
Abstract
The prostate is a walnut-sized gland that surrounds the urethra of males at the base of the bladder comprising a muscular portion, which controls the release of urine, and a glandular portion, which secretes fluids that nourish and protect sperms. Here, we report the development of a microfluidic-based model of a human prostate gland. The polydimethylsiloxane (PDMS) microfluidic device, consisting of two stacked microchannels separated by a polyester porous membrane, enables long-term in vitro cocultivation of human epithelial and stromal cells. The porous separation membrane provides an anchoring scaffold for long-term culturing of the two cell types on its opposite surfaces allowing paracrine signaling but not cell crossing between the two channels. The microfluidic device is transparent enabling high resolution bright-field and fluorescence imaging. Within this coculture model of a human epithelium/stroma interface, we simulated the functional development of the in vivo human prostate gland. We observed the successful differentiation of basal epithelial cells into luminal secretory cells determined biochemically by immunostaining with known differentiation biomarkers, particularly androgen receptor expression. We also observed morphological changes where glandlike mounds appeared with relatively empty centers reminiscent of prostatic glandular acini structures. This prostate-on-a-chip will facilitate the direct evaluation of paracrine and endocrine cross talk between these two cell types as well as studies associated with normal vs disease-related events such as prostate cancer.
Collapse
Affiliation(s)
- L. Jiang
- Department of Aerospace & Mechanical Engineering, University of Arizona, Tucson, Arizona 85721, USA
- Author to whom correspondence should be addressed:
| | - F. Ivich
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, USA
| | | | - M. Tran
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona 85721, USA
| | | | | | | |
Collapse
|
12
|
Stephens A, Nidetz R, Mesyngier N, Chung MT, Song Y, Fu J, Kurabayashi K. Mass-producible microporous silicon membranes for specific leukocyte subset isolation, immunophenotyping, and personalized immunomodulatory drug screening in vitro. LAB ON A CHIP 2019; 19:3065-3076. [PMID: 31389447 PMCID: PMC6736731 DOI: 10.1039/c9lc00315k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Widespread commercial and clinical adaptation of biomedical microfluidic technology has been limited in large part due to the lack of mass producibility of polydimethylsiloxane (PDMS) and glass-based devices commonly as reported in the literature. Here, we present a batch-fabricated, robust, and mass-producible immunophenotyping microfluidic device using silicon micromachining processes. Our Si and glass-based microfluidic device, named the silicon microfluidic immunophenotyping assay (SiMIPA), consists of a highly porous (∼40%) silicon membrane that can selectively separate microparticles below a certain size threshold. The device is capable of isolating and stimulating specific leukocyte populations, and allows for measuring their secretion of cell signaling proteins by means of a no-wash homogeneous chemiluminescence-based immunoassay. The high manufacturing throughput (∼170 devices per wafer) makes a large quantity of SiMIPA chips readily available for clinically relevant applications, which normally require large dataset acquisitions for statistical accuracy. With 30 SiMIPA chips, we performed in vitro immunomodulatory drug screening on isolated leukocyte subsets, yielding 5 data points at 6 drug concentrations. Furthermore, the excellent structural integrity of the device allowed for samples and reagents to be loaded using a micropipette, greatly simplifying the experimental protocol.
Collapse
Affiliation(s)
- Andrew Stephens
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | | | | | | | | | | | | |
Collapse
|
13
|
Abstract
Microfluidics platforms can program small amounts of fluids to execute a bio-protocol, and thus, can automate the work of a technician and also integrate a large part of laboratory equipment. Although most microfluidic systems have considerably reduced the size of a laboratory, they are still benchtop units, of a size comparable to a desktop computer. In this paper, we argue that achieving true mobility in microfluidics would revolutionize the domain by making laboratory services accessible during traveling or even in daily situations, such as sport and outdoor activities. We review the existing efforts to achieve mobility in microfluidics, and we discuss the conditions mobile biochips need to satisfy. In particular, we show how we adapted an existing biochip for mobile use, and we present the results when using it during a train ride. Based on these results and our systematic discussion, we identify the challenges that need to be overcome at technical, usability and social levels. In analogy to the history of computing, we make some predictions on the future of mobile biochips. In our vision, mobile biochips will disrupt how people interact with a wide range of healthcare processes, including medical testing and synthesis of on-demand medicine.
Collapse
Affiliation(s)
- Mirela Alistar
- Atlas Institute and Department of Computer Science, University of Colorado Boulder, Boulder, CO 80309-0320, USA.
| |
Collapse
|
14
|
Zhu J, He J, Verano M, Brimmo AT, Glia A, Qasaimeh MA, Chen P, Aleman JO, Chen W. An integrated adipose-tissue-on-chip nanoplasmonic biosensing platform for investigating obesity-associated inflammation. LAB ON A CHIP 2018; 18:3550-3560. [PMID: 30302487 PMCID: PMC6246809 DOI: 10.1039/c8lc00605a] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Although many advanced biosensing techniques have been proposed for cytokine profiling, there are no clinically available methods that integrate high-resolution immune cell monitoring and in situ multiplexed cytokine detection together in a biomimetic tissue microenvironment. The primary challenge arises due to the lack of suitable label-free sensing techniques and difficulty for sensor integration. In this work, we demonstrated a novel integration of a localized-surface plasmon resonance (LSPR)-based biosensor with a biomimetic microfluidic 'adipose-tissue-on-chip' platform for an in situ label-free, high-throughput and multiplexed cytokine secretion analysis of obese adipose tissue. Using our established adipose-tissue-on-chip platform, we were able to monitor the adipose tissue initiation, differentiation, and maturation and simulate the hallmark formation of crown-like structures (CLSs) during pro-inflammatory stimulation. With integrated antibody-conjugated LSPR barcode sensor arrays, our platform enables simultaneous multiplexed measurements of pro-inflammatory (IL-6 and TNF-α) and anti-inflammatory (IL-10 and IL-4) cytokines secreted by the adipocytes and macrophages. As a result, our adipose-tissue-on-chip platform is capable of identifying stage-specific cytokine secretion profiles from a complex milieu during obesity progression, highlighting its potential as a high-throughput preclinical readout for personalized obesity treatment strategies.
Collapse
Affiliation(s)
- Jingyi Zhu
- Department of Mechanical and Aerospace Engineering, New York University, New York, NY, USA.
| | - Jiacheng He
- Materials Research and Education Center, Materials Engineering, Department of Mechanical Engineering, Auburn University, Auburn, AL, USA
| | - Michael Verano
- Laboratory of Translational Obesity Research, Division of Endocrinology, Department of Medicine, New York University School of Medicine, New York, NY, USA
| | - Ayoola T Brimmo
- Department of Mechanical and Aerospace Engineering, New York University, New York, NY, USA. and Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
| | - Ayoub Glia
- Department of Mechanical and Aerospace Engineering, New York University, New York, NY, USA. and Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
| | - Mohammad A Qasaimeh
- Department of Mechanical and Aerospace Engineering, New York University, New York, NY, USA. and Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
| | - Pengyu Chen
- Materials Research and Education Center, Materials Engineering, Department of Mechanical Engineering, Auburn University, Auburn, AL, USA
| | - Jose O Aleman
- Laboratory of Translational Obesity Research, Division of Endocrinology, Department of Medicine, New York University School of Medicine, New York, NY, USA
| | - Weiqiang Chen
- Department of Mechanical and Aerospace Engineering, New York University, New York, NY, USA. and Department of Biomedical Engineering, New York University, New York, NY, USA
| |
Collapse
|
15
|
Tang W, Jiang D, Li Z, Zhu L, Shi J, Yang J, Xiang N. Recent advances in microfluidic cell sorting techniques based on both physical and biochemical principles. Electrophoresis 2018; 40:930-954. [DOI: 10.1002/elps.201800361] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2018] [Revised: 09/28/2018] [Accepted: 09/30/2018] [Indexed: 01/13/2023]
Affiliation(s)
- Wenlai Tang
- School of Electrical and Automation Engineering; Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing; Nanjing Normal University; P. R. China
- Nanjing Institute of Intelligent High-end Equipment Industry Co., Ltd.; P. R. China
| | - Di Jiang
- School of Mechanical and Electronic Engineering; Nanjing Forestry University; P. R. China
| | - Zongan Li
- School of Electrical and Automation Engineering; Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing; Nanjing Normal University; P. R. China
| | - Liya Zhu
- School of Electrical and Automation Engineering; Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing; Nanjing Normal University; P. R. China
| | - Jianping Shi
- School of Electrical and Automation Engineering; Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing; Nanjing Normal University; P. R. China
| | - Jiquan Yang
- School of Electrical and Automation Engineering; Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing; Nanjing Normal University; P. R. China
- Nanjing Institute of Intelligent High-end Equipment Industry Co., Ltd.; P. R. China
| | - Nan Xiang
- School of Mechanical Engineering; Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments; Southeast University; P. R. China
| |
Collapse
|
16
|
Yu ZTF, Joseph JG, Liu SX, Cheung MK, Haffey PJ, Kurabayashi K, Fu J. Centrifugal microfluidics for sorting immune cells from whole blood. SENSORS AND ACTUATORS. B, CHEMICAL 2017; 245:1050-1061. [PMID: 28966475 PMCID: PMC5619665 DOI: 10.1016/j.snb.2017.01.113] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Sorting and enumeration of immune cells from blood are critical operations involved in many clinical applications. Conventional methods for sorting and counting immune cells from blood, such as flow cytometry and hemocytometers, are tedious, inaccurate, and difficult for implementation for point-of-care (POC) testing. Herein we developed a microscale centrifugal technology termed Centrifugal Microfluidic Chip (CMC) capable of sorting immune cells from blood and in situ cellular analysis in a laboratory setting. Operation of the CMC entailed a blood specimen layered on a density gradient medium and centrifuged in microfluidic channels where immune cell subpopulations could rapidly be sorted into distinct layers according to their density differentials. We systematically studied effects of different blocking molecules for surface passivation of the CMC. We further demonstrated the applicability of CMCs for rapid separation of minimally processed human whole blood without affecting immune cell viability. Multi-color imaging and analysis of immune cell distributions and enrichment such as recovery and purity rates of peripheral blood mononuclear cells (PBMCs) were demonstrated using CMCs. Given its design and operation simplicity, portability, blood cell sorting efficiency, and in situ cellular analysis capability, the CMC holds promise for blood-based diagnosis and disease monitoring in POC applications.
Collapse
Affiliation(s)
- Zeta Tak For Yu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Jophin George Joseph
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
- Department of Chemical Engineering, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Telangana, India 502285
| | - Shirley Xiaosu Liu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Mei Ki Cheung
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Parker James Haffey
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Katsuo Kurabayashi
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Jianping Fu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
- Department of Cell and Developmental Biology, University of Michigan Medical School, Ann Arbor, MI 48109, USA
- Michigan Center for Integrative Research in Critical Care, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
17
|
Abstract
It has been demonstrated that microfluidic systems allow integration of sampling, reagent mixing, and rapid electrophoretic analysis. They have also proven useful for culturing cells wherein control over the environment allows novel and automated experiments. Here, we describe a microchip-based electrophoresis assay that allows cell culture and hormone monitoring. An online gradient generator can control cell culture condition precisely. This system has been applied for Pancreas islets' glucose sensitivity studies.
Collapse
Affiliation(s)
- Shusheng Lu
- Department of Chemistry, University of Michigan, 930 N. University Avenue, Ann Arbor, MI, 48109, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, 930 N. University Avenue, Ann Arbor, MI, 48109, USA.
- Department of Pharmacology, University of Michigan, 1150 W. Medical Center Drive, Ann Arbor, MI, 48109, USA.
| |
Collapse
|
18
|
Nanomaterial-based in vitro analytical system for diagnosis and therapy in microfluidic device. BIOCHIP JOURNAL 2016. [DOI: 10.1007/s13206-016-0409-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
19
|
Hill S, Qian W, Chen W, Fu J. Surface micromachining of polydimethylsiloxane for microfluidics applications. BIOMICROFLUIDICS 2016; 10:054114. [PMID: 27795746 PMCID: PMC5065565 DOI: 10.1063/1.4964717] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Accepted: 09/29/2016] [Indexed: 06/06/2023]
Abstract
Polydimethylsiloxane (PDMS) elastomer has emerged as one of the most frequently applied materials in microfluidics. However, precise and large-scale surface micromachining of PDMS remains challenging, limiting applications of PDMS for microfluidic structures with high-resolution features. Herein, surface patterning of PDMS was achieved using a simple yet effective method combining direct photolithography followed by reactive-ion etching (RIE). This method incorporated a unique step of using oxygen plasma to activate PDMS surfaces to a hydrophilic state, thereby enabling improved adhesion of photoresist on top of PDMS surfaces for subsequent photolithography. RIE was applied to transfer patterns from photoresist to underlying PDMS thin films. Systematic experiments were conducted in the present work to characterize PDMS etch rate and etch selectivity of PDMS to photoresist as a function of various RIE parameters, including pressure, RF power, and gas flow rate and composition. We further compared two common RIE systems with and without bias power and employed inductively coupled plasma and capacitively coupled plasma sources, respectively, in terms of their PDMS etching performances. The RIE-based PDMS surface micromachining technique is compatible with conventional Si-based surface and bulk micromachining techniques, thus opening promising opportunities for generating hybrid microfluidic devices with novel functionalities.
Collapse
Affiliation(s)
| | - Weiyi Qian
- Department of Mechanical and Aerospace Engineering, New York University , Brooklyn, New York 11201, USA
| | | | | |
Collapse
|
20
|
Ng E, Chen K, Hang A, Syed A, Zhang JXJ. Multi-Dimensional Nanostructures for Microfluidic Screening of Biomarkers: From Molecular Separation to Cancer Cell Detection. Ann Biomed Eng 2016; 44:847-62. [PMID: 26692080 PMCID: PMC4828292 DOI: 10.1007/s10439-015-1521-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Accepted: 11/20/2015] [Indexed: 12/21/2022]
Abstract
Rapid screening of biomarkers, with high specificity and accuracy, is critical for many point-of-care diagnostics. Microfluidics, the use of microscale channels to manipulate small liquid samples and carry reactions in parallel, offers tremendous opportunities to address fundamental questions in biology and provide a fast growing set of clinical tools for medicine. Emerging multi-dimensional nanostructures, when coupled with microfluidics, enable effective and efficient screening with high specificity and sensitivity, both of which are important aspects of biological detection systems. In this review, we provide an overview of current research and technologies that utilize nanostructures to facilitate biological separation in microfluidic channels. Various important physical parameters and theoretical equations that characterize and govern flow in nanostructure-integrated microfluidic channels will be introduced and discussed. The application of multi-dimensional nanostructures, including nanoparticles, nanopillars, and nanoporous layers, integrated with microfluidic channels in molecular and cellular separation will also be reviewed. Finally, we will close with insights on the future of nanostructure-integrated microfluidic platforms and their role in biological and biomedical applications.
Collapse
Affiliation(s)
- Elaine Ng
- Department of Bioengineering, Stanford University, Stanford, CA, 94305, USA.
| | - Kaina Chen
- Thayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA
| | - Annie Hang
- Thayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA
| | - Abeer Syed
- Thayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA
| | - John X J Zhang
- Thayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.
| |
Collapse
|
21
|
Boussommier-Calleja A, Li R, Chen MB, Wong SC, Kamm RD. Microfluidics: A new tool for modeling cancer-immune interactions. Trends Cancer 2016; 2:6-19. [PMID: 26858990 PMCID: PMC4743529 DOI: 10.1016/j.trecan.2015.12.003] [Citation(s) in RCA: 132] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
In recognition of the enormous potential of immunotherapies against cancer, research into the interactions between tumor and immune cells has accelerated, leading to the recent FDA approval of several drugs that reduce cancer progression. Numerous cellular and molecular interactions have been identified by which immune cells can intervene in the metastatic cascade, leading to the development of several in vivo and in vitro model systems that can recapitulate these processes. Among these, microfluidic technologies hold many advantages in terms of their unique ability to capture the essential features of multiple cell type interactions in three-dimensions while allowing tight control of the microenvironment and real-time monitoring. Here, we review current assays and discuss the development of new microfluidic technologies for immunotherapy.
Collapse
Affiliation(s)
| | - Ran Li
- Department of Biological Engineering, MIT, Cambridge, MA, USA
| | | | - Siew Cheng Wong
- Singapore Immunology Network (SIgN), Agency for Science, Technology and Research (A-STAR), Biopolis, Singapore
| | - Roger D. Kamm
- Department of Mechanical Engineering, MIT, Cambridge, MA, USA
- Department of Biological Engineering, MIT, Cambridge, MA, USA
| |
Collapse
|
22
|
Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering. SENSORS 2015; 15:31142-70. [PMID: 26690442 PMCID: PMC4721768 DOI: 10.3390/s151229848] [Citation(s) in RCA: 84] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Revised: 11/16/2015] [Accepted: 12/04/2015] [Indexed: 12/24/2022]
Abstract
Recent advances in biomedical technologies are mostly related to the convergence of biology with microengineering. For instance, microfluidic devices are now commonly found in most research centers, clinics and hospitals, contributing to more accurate studies and therapies as powerful tools for drug delivery, monitoring of specific analytes, and medical diagnostics. Most remarkably, integration of cellularized constructs within microengineered platforms has enabled the recapitulation of the physiological and pathological conditions of complex tissues and organs. The so-called “organ-on-a-chip” technology, which represents a new avenue in the field of advanced in vitro models, with the potential to revolutionize current approaches to drug screening and toxicology studies. This review aims to highlight recent advances of microfluidic-based devices towards a body-on-a-chip concept, exploring their technology and broad applications in the biomedical field.
Collapse
|
23
|
Label-free cytokine micro- and nano-biosensing towards personalized medicine of systemic inflammatory disorders. Adv Drug Deliv Rev 2015; 95:90-103. [PMID: 26408791 DOI: 10.1016/j.addr.2015.09.005] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Revised: 08/17/2015] [Accepted: 09/10/2015] [Indexed: 01/31/2023]
Abstract
Systemic inflammatory disorders resulting from infection, trauma, surgery, and severe disease conditions pose serious threats to human health leading to organ dysfunction, organ failure, and mortality. The highly complex and dynamic nature of the immune system experiencing acute inflammation makes immunomodulatory therapy blocking pro-inflammatory cytokines very challenging. Successful therapy requires the ability to determine appropriate anti-cytokine drugs to be delivered at a right dose in a timely manner. Label-free micro- and nano-biosensors hold the potential to overcome the current challenges, enabling cytokine-targeted treatments to be tailored according to the immune status of an individual host with their unique cytokine biomarker detection capabilities. This review studies the recent progress in label-free cytokine biosensors, summarizes their performances and potential merits, and discusses future directions for their advancements to meet challenges towards personalized anti-cytokine drug delivery.
Collapse
|
24
|
Qian W, Zhang Y, Chen W. Capturing Cancer: Emerging Microfluidic Technologies for the Capture and Characterization of Circulating Tumor Cells. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2015; 11:3850-72. [PMID: 25993898 DOI: 10.1002/smll.201403658] [Citation(s) in RCA: 76] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Revised: 02/13/2015] [Indexed: 05/04/2023]
Abstract
Circulating tumor cells (CTCs) escape from primary or metastatic lesions and enter into circulation, carrying significant information of cancer progression and metastasis. Capture of CTCs from the bloodstream and the characterization of these cells hold great significance for the detection, characterization, and monitoring of cancer. Despite the urgent need from clinics, it remains a major challenge to capture and retain these rare cells from human blood with high specificity and yield. Recent exciting advances in micro/nanotechnology, microfluidics, and materials science have enable versatile, robust, and efficient cell isolation and processing through the development of new micro/nanoengineered devices and biomaterials. This review provides a summary of recent progress along this direction, with a focus on emerging methods for CTC capture and processing, and their application in cancer research. Furthermore, classical as well as emerging cellular characterization methods are reviewed to reveal the role of CTCs in cancer progression and metastasis, and hypotheses are proposed in regard to the potential emerging research directions most desired in CTC-related cancer research.
Collapse
Affiliation(s)
- Weiyi Qian
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, 11201, USA
| | - Yan Zhang
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, 11201, USA
| | - Weiqiang Chen
- Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, 11201, USA
| |
Collapse
|
25
|
Concentric Magnetic Structures for Magnetophoretic Bead Collection, Cell Trapping and Analysis of Cell Morphological Changes Caused by Local Magnetic Forces. PLoS One 2015; 10:e0135299. [PMID: 26270332 PMCID: PMC4536140 DOI: 10.1371/journal.pone.0135299] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Accepted: 07/20/2015] [Indexed: 12/16/2022] Open
Abstract
Concentric magnetic structures (ring and square) with domain wall (DW) pinning geometry are designed for biological manipulation. Magnetic beads collection was firstly demonstrated to analyse the local magnetic field generated by DWs and the effective regions to capture magnetic targets of size 1 μm. Primary mouse embryonic fibroblasts (MEFs) are magnetically labeled by internalizing poly (styrene sulfonic acid) stabilized magnetic nanoparticles (PSS-MNPs) and then are selectively trapped by head-to-tail DWs (HH DWs) or tail-to-tail DWs (TT DWs) to be arranged into linear shape or cross shape. The morphologies and the nuclear geometry of the cells growing on two kinds of concentric magnetic structures are shown to be distinctive. The intracellular magnetic forces generated by the local magnetic field of DWs are found to influence the behaviour of cells.
Collapse
|
26
|
Vu T, Rahimian A, Stybayeva G, Gao Y, Kwa T, Van de Water J, Revzin A. Reconfigurable microfluidic device with integrated antibody arrays for capture, multiplexed stimulation, and cytokine profiling of human monocytes. BIOMICROFLUIDICS 2015; 9:044115. [PMID: 26339315 PMCID: PMC4529433 DOI: 10.1063/1.4928128] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Accepted: 07/27/2015] [Indexed: 06/05/2023]
Abstract
Monocytes represent a class of immune cells that play a key role in the innate and adaptive immune response against infections. One mechanism employed by monocytes for sensing foreign antigens is via toll-like receptors (TLRs)-transmembrane proteins that distinguish classes of foreign pathogens, for example, bacteria (TLR4, 5, and 9) vs. fungi (TLR2) vs. viruses (TLR3, 7, and 8). Binding of antigens activates a signaling cascade through TLR receptors that culminate in secretion of inflammatory cytokines. Detection of these cytokines can provide valuable clinical data for drug developers and disease investigations, but this usually requires a large sample volume and can be technically inefficient with traditional techniques such as flow cytometry, enzyme-linked immunosorbent assay, or luminex. This paper describes an approach whereby antibody arrays for capturing cells and secreted cytokines are encapsulated within a microfluidic device that can be reconfigured to operate in serial or parallel mode. In serial mode, the device represents one long channel that may be perfused with a small volume of minimally processed blood. Once monocytes are captured onto antibody spots imprinted into the floor of the device, the straight channel is reconfigured to form nine individually perfusable chambers. To prove this concept, the microfluidic platform was used to capture monocytes from minimally processed human blood in serial mode and then to stimulate monocytes with different TLR agonists in parallel mode. Three cytokines, tumor necrosis factor-α, interleukin (IL)-6, and IL-10, were detected using anti-cytokine antibody arrays integrated into each of the six chambers. We foresee further use of this device in applications such as pediatric immunology or drug/vaccine testing where it is important to balance small sample volume with the need for high information content.
Collapse
Affiliation(s)
- Tam Vu
- Department of Biomedical Engineering, University of California , 451 Health Sciences Drive, Suite 2619, Davis, California 95616, USA
| | - Ali Rahimian
- Department of Biomedical Engineering, University of California , 451 Health Sciences Drive, Suite 2619, Davis, California 95616, USA
| | - Gulnaz Stybayeva
- Department of Biomedical Engineering, University of California , 451 Health Sciences Drive, Suite 2619, Davis, California 95616, USA
| | - Yandong Gao
- Department of Biomedical Engineering, University of California , 451 Health Sciences Drive, Suite 2619, Davis, California 95616, USA
| | - Timothy Kwa
- Department of Biomedical Engineering, University of California , 451 Health Sciences Drive, Suite 2619, Davis, California 95616, USA
| | - Judy Van de Water
- Division of Rheumatology, Allergy and Clinical Immunology, University of California at Davis School of Medicine , 451 Health Sciences Drive, Suite 6510, Davis, California 95616, USA
| | - Alexander Revzin
- Department of Biomedical Engineering, University of California , 451 Health Sciences Drive, Suite 2619, Davis, California 95616, USA
| |
Collapse
|
27
|
Yu ZTF, Guan H, Cheung MK, McHugh WM, Cornell TT, Shanley TP, Kurabayashi K, Fu J. Rapid, automated, parallel quantitative immunoassays using highly integrated microfluidics and AlphaLISA. Sci Rep 2015; 5:11339. [PMID: 26074253 PMCID: PMC4466892 DOI: 10.1038/srep11339] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Accepted: 05/15/2015] [Indexed: 12/22/2022] Open
Abstract
Immunoassays represent one of the most popular analytical methods for detection and quantification of biomolecules. However, conventional immunoassays such as ELISA and flow cytometry, even though providing high sensitivity and specificity and multiplexing capability, can be labor-intensive and prone to human error, making them unsuitable for standardized clinical diagnoses. Using a commercialized no-wash, homogeneous immunoassay technology ('AlphaLISA') in conjunction with integrated microfluidics, herein we developed a microfluidic immunoassay chip capable of rapid, automated, parallel immunoassays of microliter quantities of samples. Operation of the microfluidic immunoassay chip entailed rapid mixing and conjugation of AlphaLISA components with target analytes before quantitative imaging for analyte detections in up to eight samples simultaneously. Aspects such as fluid handling and operation, surface passivation, imaging uniformity, and detection sensitivity of the microfluidic immunoassay chip using AlphaLISA were investigated. The microfluidic immunoassay chip could detect one target analyte simultaneously for up to eight samples in 45 min with a limit of detection down to 10 pg mL(-1). The microfluidic immunoassay chip was further utilized for functional immunophenotyping to examine cytokine secretion from human immune cells stimulated ex vivo. Together, the microfluidic immunoassay chip provides a promising high-throughput, high-content platform for rapid, automated, parallel quantitative immunosensing applications.
Collapse
Affiliation(s)
- Zeta Tak For Yu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Huijiao Guan
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Mei Ki Cheung
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Walker M McHugh
- Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Timothy T Cornell
- Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Thomas P Shanley
- Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Katsuo Kurabayashi
- 1] Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA [2] Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Jianping Fu
- 1] Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA [2] Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| |
Collapse
|
28
|
Gopalakrishnan N, Hannam R, Casoni GP, Barriet D, Ribe JM, Haug M, Halaas Ø. Infection and immunity on a chip: a compartmentalised microfluidic platform to monitor immune cell behaviour in real time. LAB ON A CHIP 2015; 15:1481-1487. [PMID: 25608968 DOI: 10.1039/c4lc01438c] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Cells respond to their environments and self-organise into multicellular assemblies with dedicated functions. The migratory and homing response of cells to soluble ligands can be studied by using different techniques, but for real time studies of complex multicellular self-organisation, novel and simpler systems are required. We fabricated a flexible open access microsystem and tested the design by studying cell recruitment from an immune cell reservoir towards an infectious compartment. The two compartments were connected by a network of bifurcated microchannels allowing diffusion of signalling molecules and migration of cells. Bacterial filters were incorporated in the design to prevent bacteria and activated cells from entering the network, permitting migration only from the recruitment reservoir. The fabricated microsystem allows real-time continuous monitoring of cellular decision-making based on biologically produced gradients of cytokines and chemokines. It is a valuable tool for studying cellular migration and self-organisation in relation to infections, autoimmunity, cancer, stem cell homing, and tissue and wound repair.
Collapse
Affiliation(s)
- N Gopalakrishnan
- Dept. of Cancer Research and Molecular Medicine, Norwegian University of Science and Technology, 7489 Trondheim, Norway.
| | | | | | | | | | | | | |
Collapse
|
29
|
Li X, Chen W, Li Z, Li L, Gu H, Fu J. Emerging microengineered tools for functional analysis and phenotyping of blood cells. Trends Biotechnol 2014; 32:586-594. [PMID: 25283971 DOI: 10.1016/j.tibtech.2014.09.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2014] [Revised: 09/09/2014] [Accepted: 09/09/2014] [Indexed: 01/09/2023]
Abstract
The available techniques for assessing blood cell functions are limited considering the various types of blood cell and their diverse functions. In the past decade, rapid advances in microengineering have enabled an array of blood cell functional measurements that are difficult or impossible to achieve using conventional bulk platforms. Such miniaturized blood cell assay platforms also provide the attractive capabilities of reducing chemical consumption, cost, and assay time, as well as exciting opportunities for device integration, automation, and assay standardization. This review summarizes these contemporary microengineered tools and discusses their promising potential for constructing accurate in vitro models and rapid clinical diagnosis using minimal amounts of whole-blood samples.
Collapse
Affiliation(s)
- Xiang Li
- Integrated Biosystems and Biomechanics Laboratory, University of Michigan, Ann Arbor, MI 48109, USA; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - Weiqiang Chen
- Integrated Biosystems and Biomechanics Laboratory, University of Michigan, Ann Arbor, MI 48109, USA; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - Zida Li
- Integrated Biosystems and Biomechanics Laboratory, University of Michigan, Ann Arbor, MI 48109, USA; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - Ling Li
- Department of Precision Instruments, Tsinghua University, Beijing 100084, China
| | - Hongchen Gu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Jianping Fu
- Integrated Biosystems and Biomechanics Laboratory, University of Michigan, Ann Arbor, MI 48109, USA; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.
| |
Collapse
|
30
|
Methods to study the tumor microenvironment under controlled oxygen conditions. Trends Biotechnol 2014; 32:556-563. [PMID: 25282035 DOI: 10.1016/j.tibtech.2014.09.006] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 08/25/2014] [Accepted: 09/09/2014] [Indexed: 12/16/2022]
Abstract
The tumor microenvironment (TME) is a complex heterogeneous assembly composed of a variety of cell types and physical features. One such feature, hypoxia, is associated with metabolic reprogramming, the epithelial-mesenchymal transition, and therapeutic resistance. Many questions remain regarding the effects of hypoxia on these outcomes; however, only a few experimental methods enable both precise control over oxygen concentration and real-time imaging of cell behavior. Recent efforts with microfluidic platforms offer a promising solution to these limitations. In this review, we discuss conventional methods and tools used to control oxygen concentration for cell studies, and then highlight recent advances in microfluidic-based approaches for controlling oxygen in engineered platforms.
Collapse
|
31
|
Dolega ME, Wagh J, Gerbaud S, Kermarrec F, Alcaraz JP, Martin DK, Gidrol X, Picollet-D’hahan N. Facile bench-top fabrication of enclosed circular microchannels provides 3D confined structure for growth of prostate epithelial cells. PLoS One 2014; 9:e99416. [PMID: 24945245 PMCID: PMC4063722 DOI: 10.1371/journal.pone.0099416] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Accepted: 05/14/2014] [Indexed: 12/15/2022] Open
Abstract
We present a simple bench-top method to fabricate enclosed circular channels for biological experiments. Fabricating the channels takes less than 2 hours by using glass capillaries of various diameters (from 100 µm up to 400 µm) as a mould in PDMS. The inner surface of microchannels prepared in this way was coated with a thin membrane of either Matrigel or a layer-by-layer polyelectrolyte to control cellular adhesion. The microchannels were then used as scaffolds for 3D-confined epithelial cell culture. To show that our device can be used with several epithelial cell types from exocrine glandular tissues, we performed our biological studies on adherent epithelial prostate cells (non-malignant RWPE-1 and invasive PC3) and also on breast (non-malignant MCF10A) cells We observed that in static conditions cells adhere and proliferate to form a confluent layer in channels of 150 µm in diameter and larger, whereas cellular viability decreases with decreasing diameter of the channel. Matrigel and PSS (poly (sodium 4-styrenesulphonate)) promote cell adhesion, whereas the cell proliferation rate was reduced on the PAH (poly (allylamine hydrochloride))-terminated surface. Moreover infusing channels with a continuous flow did not induce any cellular detachment. Our system is designed to simply grow cells in a microchannel structure and could be easily fabricated in any biological laboratory. It offers opportunities to grow epithelial cells that support the formation of a light. This system could be eventually used, for example, to collect cellular secretions, or study cell responses to graduated hypoxia conditions, to chemicals (drugs, siRNA, …) and/or physiological shear stress.
Collapse
Affiliation(s)
- Monika E. Dolega
- Univ. Grenoble Alpes, iRTSV-BGE, Grenoble, France
- CEA, iRTSV-BGE, Grenoble, France
- INSERM, BGE, Grenoble, France
| | - Jayesh Wagh
- Univ. Grenoble Alpes, iRTSV-BGE, Grenoble, France
- CEA, iRTSV-BGE, Grenoble, France
- INSERM, BGE, Grenoble, France
| | - Sophie Gerbaud
- Univ. Grenoble Alpes, iRTSV-BGE, Grenoble, France
- CEA, iRTSV-BGE, Grenoble, France
- INSERM, BGE, Grenoble, France
| | - Frederique Kermarrec
- Univ. Grenoble Alpes, iRTSV-BGE, Grenoble, France
- CEA, iRTSV-BGE, Grenoble, France
- INSERM, BGE, Grenoble, France
| | | | - Donald K. Martin
- UJF-Grenoble 1, CNRS, TIMC-IMAG UMR 5525 (SyNaBi), Grenoble, France
| | - Xavier Gidrol
- Univ. Grenoble Alpes, iRTSV-BGE, Grenoble, France
- CEA, iRTSV-BGE, Grenoble, France
- INSERM, BGE, Grenoble, France
| | - Nathalie Picollet-D’hahan
- Univ. Grenoble Alpes, iRTSV-BGE, Grenoble, France
- CEA, iRTSV-BGE, Grenoble, France
- INSERM, BGE, Grenoble, France
- * E-mail:
| |
Collapse
|
32
|
Yu ZTF, Yong KMA, Fu J. Microfluidic blood cell sorting: now and beyond. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2014; 10:1687-703. [PMID: 24515899 PMCID: PMC4013196 DOI: 10.1002/smll.201302907] [Citation(s) in RCA: 101] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2013] [Revised: 12/16/2013] [Indexed: 05/15/2023]
Abstract
Blood plays an important role in homeostatic regulation with each of its cellular components having important therapeutic and diagnostic uses. Therefore, separation and sorting of blood cells hasa been of a great interest to clinicians and researchers. However, while conventional methods of processing blood have been successful in generating relatively pure fractions, they are time consuming, labor intensive, and are not optimal for processing small volume blood samples. In recent years, microfluidics has garnered great interest from clinicians and researchers as a powerful technology for separating blood into different cell fractions. As microfluidics involves fluid manipulation at the microscale level, it has the potential for achieving high-resolution separation and sorting of blood cells down to a single-cell level, with an added benefit of integrating physical and biological methods for blood cell separation and analysis on the same single chip platform. This paper will first review the conventional methods of processing and sorting blood cells, followed by a discussion on how microfluidics is emerging as an efficient tool to rapidly change the field of blood cell sorting for blood-based therapeutic and diagnostic applications.
Collapse
Affiliation(s)
- Zeta Tak For Yu
- Integrated Biosystems and Biomechanics Laboratory, University of
Michigan, Ann Arbor, Michigan, USA
- Department of Mechanical Engineering, University of Michigan, Ann
Arbor, Michigan, USA
| | - Koh Meng Aw Yong
- Integrated Biosystems and Biomechanics Laboratory, University of
Michigan, Ann Arbor, Michigan, USA
- Department of Mechanical Engineering, University of Michigan, Ann
Arbor, Michigan, USA
| | - Jianping Fu
- Integrated Biosystems and Biomechanics Laboratory, University of
Michigan, Ann Arbor, Michigan, USA
- Department of Mechanical Engineering, University of Michigan, Ann
Arbor, Michigan, USA
- Department of Biomedical Engineering, University of Michigan, Ann
Arbor, Michigan, USA
| |
Collapse
|
33
|
Junkin M, Tay S. Microfluidic single-cell analysis for systems immunology. LAB ON A CHIP 2014; 14:1246-60. [PMID: 24503696 DOI: 10.1039/c3lc51182k] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
The immune system constantly battles infection and tissue damage, but exaggerated immune responses lead to allergies, autoimmunity and cancer. Discrimination of self from foreign and the fine-tuning of immunity are achieved by information processing pathways, whose regulatory mechanisms are little understood. Cell-to-cell variability and stochastic molecular interactions result in diverse cellular responses to identical signaling inputs, casting doubt on the reliability of traditional population-averaged analyses. Furthermore, dynamic molecular and cellular interactions create emergent properties that change over multiple time scales. Understanding immunity in the face of complexity and noisy dynamics requires time-dependent analysis of single-cells in a proper context. Microfluidic systems create precisely defined microenvironments by controlling fluidic and surface chemistries, feature sizes, geometries and signal input timing, and thus enable quantitative multi-parameter analysis of single cells. Such qualities allow observable dynamic environments approaching in vivo levels of biological complexity. Seamless parallelization of functional units in microfluidic devices allows high-throughput measurements, an essential feature for statistically meaningful analysis of naturally variable biological systems. These abilities recapitulate diverse scenarios such as cell-cell signaling, migration, differentiation, antibody and cytokine production, clonal selection, and cell lysis, thereby enabling accurate and meaningful study of immune behaviors in vitro.
Collapse
Affiliation(s)
- Michael Junkin
- Department of Biosystems Science and Engineering, ETH Zürich, Switzerland.
| | | |
Collapse
|
34
|
Young EWK. Cells, tissues, and organs on chips: challenges and opportunities for the cancer tumor microenvironment. Integr Biol (Camb) 2014; 5:1096-109. [PMID: 23799587 DOI: 10.1039/c3ib40076j] [Citation(s) in RCA: 115] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The transition to increasingly sophisticated microfluidic systems has led to the emergence of "organ-on-chip" technology that can faithfully recapitulate organ-level function. Given the rapid progress at the interface between microfluidics and cell biology, there is need to provide a focused evaluation of the state-of-the-art in microfluidic systems for cancer research to advance development, accelerate discovery of novel insights, and facilitate cooperation between engineers, biologists and oncologists in the clinic. Here, we provide a focused review of microfluidics technology from cells- and tissues- to organs-on-chips with application toward studying the tumor microenvironment. Key aspects of the tumor microenvironment including angiogenesis, hypoxia, biochemical gradients, tumor-stromal interactions, and the extracellular matrix are summarized for both solid tumors and non-solid hematologic malignancies. An overview of microfluidic systems designed specifically to answer questions related to different aspects of the tumor microenvironment is provided, followed by an examination of how these systems offer new opportunities to study outstanding challenges related to the major cancer hallmarks. Challenges also remain for microfluidics engineers, but it is hoped that cooperation between engineers and biologists at the intersection of their respective fields will lead to significant impact on the utility of organs-on-chips in cancer research.
Collapse
Affiliation(s)
- Edmond W K Young
- Department of Mechanical & Industrial Engineering, University of Toronto, 5 King's College Road, MC314B, Toronto, ON M5S 3G8, Canada.
| |
Collapse
|
35
|
Oh BR, Huang NT, Chen W, Seo JH, Chen P, Cornell TT, Shanley TP, Fu J, Kurabayashi K. Integrated nanoplasmonic sensing for cellular functional immunoanalysis using human blood. ACS NANO 2014; 8:2667-76. [PMID: 24568576 PMCID: PMC4004291 DOI: 10.1021/nn406370u] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2013] [Accepted: 02/19/2014] [Indexed: 05/18/2023]
Abstract
Localized surface plasmon resonance (LSPR) nanoplasmonic effects allow for label-free, real-time detection of biomolecule binding events on a nanostructured metallic surface with simple optics and sensing tunability. Despite numerous reports on LSPR bionanosensing in the past, no study thus far has applied the technique for a cytokine secretion assay using clinically relevant immune cells from human blood. Cytokine secretion assays, a technique to quantify intercellular-signaling proteins secreted by blood immune cells, allow determination of the functional response of the donor's immune cells, thus providing valuable information about the immune status of the donor. However, implementation of LSPR bionanosensing in cellular functional immunoanalysis based on a cytokine secretion assay poses major challenges primarily owing to its limited sensitivity and a lack of sufficient sample handling capability. In this paper, we have developed a label-free LSPR biosensing technique to detect cell-secreted tumor necrosis factor (TNF)-α cytokines in clinical blood samples. Our approach integrates LSPR bionanosensors in an optofluidic platform that permits trapping and stimulation of target immune cells in a microfluidic chamber with optical access for subsequent cytokine detection. The on-chip spatial confinement of the cells is the key to rapidly increasing a cytokine concentration high enough for detection by the LSPR setup, thereby allowing the assay time and sample volume to be significantly reduced. We have successfully applied this approach first to THP-1 cells and then later to CD45 cells isolated directly from human blood. Our LSPR optofluidics device allows for detection of TNF-α secreted from cells as few as 1000, which translates into a nearly 100 times decrease in sample volume than conventional cytokine secretion assay techniques require. We achieved cellular functional immunoanalysis with a minimal blood sample volume (3 μL) and a total assay time 3 times shorter than that of the conventional enzyme-linked immunosorbent assay (ELISA).
Collapse
Affiliation(s)
- Bo-Ram Oh
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Nien-Tsu Huang
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Electrical Engineering, Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Weiqiang Chen
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Jung Hwan Seo
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Mechanical and Design Engineering, Hongik University, Seoul, South Korea
| | - Pengyu Chen
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Timothy T. Cornell
- Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Thomas P. Shanley
- Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Jianping Fu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Katsuo Kurabayashi
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109, United States
- Address correspondence to
| |
Collapse
|
36
|
Chen Y, Li S, Gu Y, Li P, Ding X, Wang L, McCoy JP, Levine SJ, Huang TJ. Continuous enrichment of low-abundance cell samples using standing surface acoustic waves (SSAW). LAB ON A CHIP 2014; 14:924-30. [PMID: 24413889 PMCID: PMC4688895 DOI: 10.1039/c3lc51001h] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Cell enrichment is a powerful tool in a variety of cellular studies, especially in applications with low-abundance cell types. In this work, we developed a standing surface acoustic wave (SSAW) based microfluidic device for non-contact, continuous cell enrichment. With a pair of parallel interdigital transducers (IDT) deposited on a piezoelectric substrate, a one-dimensional SSAW field was established along disposable micro-tubing channels, generating numerous pressure nodes (and thus numerous cell-enrichment regions). Our method is able to concentrate highly diluted blood cells by more than 100 fold with a recovery efficiency of up to 99%. Such highly effective cell enrichment was achieved without using sheath flow. The SSAW-based technique presented here is simple, bio-compatible, label-free, and sheath-flow-free. With these advantages, it could be valuable for many biomedical applications.
Collapse
Affiliation(s)
- Yuchao Chen
- Department of Engineering Science and Mechanics, The Pennsylvania, State University, University Park, PA 16802, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Baratchi S, Khoshmanesh K, Sacristán C, Depoil D, Wlodkowic D, McIntyre P, Mitchell A. Immunology on chip: Promises and opportunities. Biotechnol Adv 2014; 32:333-46. [DOI: 10.1016/j.biotechadv.2013.11.008] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2013] [Revised: 11/04/2013] [Accepted: 11/17/2013] [Indexed: 01/09/2023]
|
38
|
|
39
|
Culbertson CT, Mickleburgh TG, Stewart-James SA, Sellens KA, Pressnall M. Micro total analysis systems: fundamental advances and biological applications. Anal Chem 2014; 86:95-118. [PMID: 24274655 PMCID: PMC3951881 DOI: 10.1021/ac403688g] [Citation(s) in RCA: 106] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
| | - Tom G. Mickleburgh
- Department of Chemistry, Kansas State University, Manhattan, Kansas 66506, USA
| | | | - Kathleen A. Sellens
- Department of Chemistry, Kansas State University, Manhattan, Kansas 66506, USA
| | - Melissa Pressnall
- Department of Chemistry, Kansas State University, Manhattan, Kansas 66506, USA
| |
Collapse
|
40
|
Mirasoli M, Guardigli M, Michelini E, Roda A. Recent advancements in chemical luminescence-based lab-on-chip and microfluidic platforms for bioanalysis. J Pharm Biomed Anal 2014; 87:36-52. [DOI: 10.1016/j.jpba.2013.07.008] [Citation(s) in RCA: 122] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Revised: 07/08/2013] [Accepted: 07/08/2013] [Indexed: 01/27/2023]
|
41
|
Dubeau-Laramée G, Rivière C, Jean I, Mermut O, Cohen LY. Microflow1, a sheathless fiber-optic flow cytometry biomedical platform: Demonstration onboard the international space station. Cytometry A 2013; 85:322-31. [DOI: 10.1002/cyto.a.22427] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2013] [Revised: 11/08/2013] [Accepted: 11/26/2013] [Indexed: 11/05/2022]
Affiliation(s)
| | | | | | - Ozzy Mermut
- Institut National d'Optique; Quebec City Quebec Canada
| | | |
Collapse
|
42
|
A simple and portable device for the quantification of TNF-α in human plasma by means of on-chip magnetic bead-based proximity ligation assay. Biosens Bioelectron 2013; 54:499-505. [PMID: 24316452 DOI: 10.1016/j.bios.2013.10.039] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2013] [Revised: 10/11/2013] [Accepted: 10/22/2013] [Indexed: 02/02/2023]
Abstract
There is a general need in healthcare systems all around the world to reduce costs in terms of time and money without compromising patients outcome. Point-of-Care Testing (POCT) is currently being used in some applications (e.g. POC coagulation devices) as an alternative to already established standard central laboratory tests to overcome sample transportation and long turnaround times. The main objective of this investigation was to quantify Tumour Necrosis Factor-alpha (TNF-α) on-chip within the clinical relevant range of 5-100 pg/mL in human pooled plasma. The novel solid-phase assay developed in this study was a magnetic bead-based proximity ligation assay (PLA) in which one of the assay proximity probes was directly immobilised onto streptavidin-coated magnetic beads. The portable device was based on a disposable and single-use cyclo-olefin polymer (COP) microfluidic chip interfaced with a quantitative real-time polymerase chain reaction (qPCR) device previously developed in-house. Sample volume was 10 µL and total assay time under 3 h. The POC device and assay developed offer portability, smaller reagent and sample consumption, and faster time-to-results compared with standard ELISAs. Determination and monitoring of TNF-α therapy at the point-of-care will help to improve clinical and/or economical outcome in governmental healthcare budgets.
Collapse
|
43
|
Eyer K, Kuhn P, Stratz S, Dittrich PS. A microfluidic chip for the versatile chemical analysis of single cells. J Vis Exp 2013:e50618. [PMID: 24192501 DOI: 10.3791/50618] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
We present a microfluidic device that enables the quantitative determination of intracellular biomolecules in multiple single cells in parallel. For this purpose, the cells are passively trapped in the middle of a microchamber. Upon activation of the control layer, the cell is isolated from the surrounding volume in a small chamber. The surrounding volume can then be exchanged without affecting the isolated cell. However, upon short opening and closing of the chamber, the solution in the chamber can be replaced within a few hundred milliseconds. Due to the reversibility of the chambers, the cells can be exposed to different solutions sequentially in a highly controllable fashion, e.g. for incubation, washing, and finally, cell lysis. The tightly sealed microchambers enable the retention of the lysate, minimize and control the dilution after cell lysis. Since lysis and analysis occur at the same location, high sensitivity is retained because no further dilution or loss of the analytes occurs during transport. The microchamber design therefore enables the reliable and reproducible analysis of very small copy numbers of intracellular molecules (attomoles, zeptomoles) released from individual cells. Furthermore, many microchambers can be arranged in an array format, allowing the analysis of many cells at once, given that suitable optical instruments are used for monitoring. We have already used the platform for proof-of-concept studies to analyze intracellular proteins, enzymes, cofactors and second messengers in either relative or absolute quantifiable manner.
Collapse
Affiliation(s)
- Klaus Eyer
- Department of Chemistry and Applied Biosciences, ETH Zurich, Switzerland
| | | | | | | |
Collapse
|
44
|
Chen W, Huang NT, Oh B, Lam RHW, Fan R, Cornell TT, Shanley TP, Kurabayashi K, Fu J. Surface-micromachined microfiltration membranes for efficient isolation and functional immunophenotyping of subpopulations of immune cells. Adv Healthc Mater 2013; 2:965-975. [PMID: 23335389 DOI: 10.1002/adhm.201200378] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2012] [Indexed: 01/02/2023]
Abstract
An accurate measurement of the immune status in patients with immune system disorders is critical in evaluating the stage of diseases and tailoring drug treatments. The functional cellular immunity test is a promising method to establish the diagnosis of immune dysfunctions. The conventional functional cellular immunity test involves measurements of the capacity of peripheral blood mononuclear cells to produce pro-inflammatory cytokines when stimulated ex vivo. However, this "bulk" assay measures the overall reactivity of a population of lymphocytes and monocytes, making it difficult to pinpoint the phenotype or real identity of the reactive immune cells involved. In this research, we develop a large surface micromachined poly-dimethylsiloxane (PDMS) microfiltration membrane (PMM) with high porosity, which is integrated in a microfluidic microfiltration platform. Using the PMM with functionalized microbeads conjugated with antibodies against specific cell surface proteins, we demonstrated rapid, efficient and high-throughput on-chip isolation, enrichment, and stimulation of subpopulations of immune cells from blood specimens. Furthermore, the PMM-integrated microfiltration platform, coupled with a no-wash homogeneous chemiluminescence assay ("AlphaLISA"), enables us to demonstrate rapid and sensitive on-chip immunophenotyping assays for subpopulations of immune cells isolated directly from minute quantities of blood samples.
Collapse
Affiliation(s)
- Weiqiang Chen
- Department of Mechanical Engineering University of Michigan Ann Arbor, MI 48109 USA
| | - Nien-Tsu Huang
- Department of Mechanical Engineering University of Michigan Ann Arbor, MI 48109 USA
| | - Boram Oh
- Department of Mechanical Engineering University of Michigan Ann Arbor, MI 48109 USA
| | - Raymond H W Lam
- Department of Mechanical and Biomedical Engineering City University of Hong Kong, Hong Kong, China
| | - Rong Fan
- Department of Biomedical Engineering Yale University New Haven, CT 06511, USA
| | - Timothy T Cornell
- Department of Pediatrics and Communicable Diseases University of Michigan, Ann Arbor, MI 48109, USA
| | - Thomas P Shanley
- Department of Pediatrics and Communicable Diseases University of Michigan, Ann Arbor, MI 48109, USA
| | - Katsuo Kurabayashi
- Department of Mechanical Engineering University of Michigan Ann Arbor, MI 48109 USA
| | - Jianping Fu
- Department of Mechanical Engineering University of Michigan Ann Arbor, MI 48109 USA
| |
Collapse
|
45
|
Chen W, Huang NT, Li X, Yu ZTF, Kurabayashi K, Fu J. Emerging microfluidic tools for functional cellular immunophenotyping: a new potential paradigm for immune status characterization. Front Oncol 2013; 3:98. [PMID: 23626950 DOI: 10.3389/fonc.2013.00098] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2013] [Accepted: 04/10/2013] [Indexed: 11/13/2022] Open
Abstract
Rapid, accurate, and quantitative characterization of immune status of patients is of utmost importance for disease diagnosis and prognosis, evaluating efficacy of immunotherapeutics and tailoring drug treatments. Immune status of patients is often dynamic and patient-specific, and such complex heterogeneity has made accurate, real-time measurements of patient immune status challenging in the clinical setting. Recent advances in microfluidics have demonstrated promising applications of the technology for immune monitoring with minimum sample requirements and rapid functional immunophenotyping capability. This review will highlight recent developments of microfluidic platforms that can perform rapid and accurate cellular functional assays on patient immune cells. We will also discuss the future potential of integrated microfluidics to perform rapid, accurate, and sensitive cellular functional assays at a single-cell resolution on different types or subpopulations of immune cells, to provide an unprecedented level of information depth on the distribution of immune cell functionalities. We envision that such microfluidic immunophenotyping tools will allow for comprehensive and systems-level immunomonitoring, unlocking the potential to transform experimental clinical immunology into an information-rich science.
Collapse
Affiliation(s)
- Weiqiang Chen
- Integrated Biosystems and Biomechanics Laboratory, University of Michigan Ann Arbor, MI, USA ; Department of Mechanical Engineering, University of Michigan Ann Arbor, MI, USA
| | | | | | | | | | | |
Collapse
|
46
|
Warkiani ME, Bhagat AAS, Khoo BL, Han J, Lim CT, Gong HQ, Fane AG. Isoporous micro/nanoengineered membranes. ACS NANO 2013; 7:1882-1904. [PMID: 23442009 DOI: 10.1021/nn305616k] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Isoporous membranes are versatile structures with numerous potential and realized applications in various fields of science such as micro/nanofiltration, cell separation and harvesting, controlled drug delivery, optics, gas separation, and chromatography. Recent advances in micro/nanofabrication techniques and material synthesis provide novel methods toward controlling the detailed microstructure of membrane materials, allowing fabrication of membranes with well-defined pore size and shape. This review summarizes the current state-of-the-art for isoporous membrane fabrication using different techniques, including microfabrication, anodization, and advanced material synthesis. Various applications of isoporous membranes, such as protein filtration, pathogen isolation, cell harvesting, biosensing, and drug delivery, are also presented.
Collapse
Affiliation(s)
- Majid Ebrahimi Warkiani
- BioSystems and Micromechanics (BioSyM) IRG, Singapore-MIT Alliance for Research and Technology (SMART) Centre, Singapore.
| | | | | | | | | | | | | |
Collapse
|
47
|
Eyer K, Stratz S, Kuhn P, Küster SK, Dittrich PS. Implementing Enzyme-Linked Immunosorbent Assays on a Microfluidic Chip To Quantify Intracellular Molecules in Single Cells. Anal Chem 2013; 85:3280-7. [DOI: 10.1021/ac303628j] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- K. Eyer
- Department of Chemistry and Applied Biosciences, ETH Zurich, Wolfgang-Pauli-Str. 10,
CH-8093 Zurich, Switzerland
| | - S. Stratz
- Department of Chemistry and Applied Biosciences, ETH Zurich, Wolfgang-Pauli-Str. 10,
CH-8093 Zurich, Switzerland
| | - P. Kuhn
- Department of Chemistry and Applied Biosciences, ETH Zurich, Wolfgang-Pauli-Str. 10,
CH-8093 Zurich, Switzerland
| | - S. K. Küster
- Department of Chemistry and Applied Biosciences, ETH Zurich, Wolfgang-Pauli-Str. 10,
CH-8093 Zurich, Switzerland
| | - P. S. Dittrich
- Department of Chemistry and Applied Biosciences, ETH Zurich, Wolfgang-Pauli-Str. 10,
CH-8093 Zurich, Switzerland
| |
Collapse
|