1
|
Liu H, Zhang Y, Lyu Z, Cheng L, Gao L, Wu J, Liu Y. Investigation of a deep learning-based reconstruction approach utilizing dual-view projection for myocardial perfusion SPECT imaging. AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING 2025; 15:15-27. [PMID: 40124765 PMCID: PMC11929010 DOI: 10.62347/mlfb9278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2024] [Accepted: 02/23/2025] [Indexed: 03/25/2025]
Abstract
Single-photon emission computed tomography (SPECT) is widely used in myocardial perfusion imaging (MPI) in clinic. However, conventional dual-head SPECT scanners require lengthy scanning times and gantry rotation, which limits the application of SPECT MPI. In this work, we proposed a deep learning-based approach to reconstruct dual-view projections, aiming to reduce acquisition time and enable non-rotational imaging for MPI based on conventional dual-head SPECT scanners. U-Net was adopted for the dual-view projection reconstruction. Initially, 2D U-Nets were used to evaluate various data organization schemes for dual-view projection as input, including paved projection, interleaved projection, and stacked projection, with and without an attenuation map. Subsequently, we developed 3D U-Nets using the optimal data organization scheme as input to further enhance reconstruction performance. The dataset consisted of a total of 116 SPECT/CT scans with 99mTc-tetrofosmin tracer acquired on a GE NM/CT 640 scanner. Reconstruction performance was assessed using quantitative metrices and absolute percentage errors, while the reconstruction images from the full-view projection were used as reference images. The 2D U-Nets provided reasonable transverse view images but exhibited slight axial discontinuity compared to the reference images, regardless of the data organization schemes. Incorporating the attenuation map reduced this axial discontinuity. Quantitatively, the 2D U-Net trained using both stacked projection and attenuation map achieved the best performance, with a normalized mean absolute error of 0.6%±0.3% and a structural similarity index measure (SSIM) of 0.93±0.04. The 3D U-Net further improved the performance with less axial discontinuity and a higher SSIM of 0.94±0.03. The localized absolute percentage errors were 1.8±16.8% and -2.0±6.3% in the left ventricular (LV) cavity and myocardium, respectively. We developed a deep learning-based image reconstruction approach for dual-view projection from a conventional SPECT scanner. The 3D U-Net, trained with the stacked projection with an attenuation map is effective for non-rotational imaging and could benefit dynamic myocardium perfusion imaging.
Collapse
Affiliation(s)
- Hui Liu
- Department of Engineering Physics, Tsinghua UniversityBeijing, China
- Key Laboratory of Particle and Radiation Imaging (Tsinghua University), Ministry of EducationBeijing, China
| | - Yajing Zhang
- Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhan, Hubei, China
| | - Zhenlei Lyu
- Department of Engineering Physics, Tsinghua UniversityBeijing, China
| | - Li Cheng
- Chengdu Novel Medical Equipment Ltd.Chengdu, Sichuan, China
| | - Lilei Gao
- Chengdu Novel Medical Equipment Ltd.Chengdu, Sichuan, China
| | - Jing Wu
- Center for Advanced Quantum Studies, School of Physics and Astronomy, Beijing Normal UniversityBeijing, China
- Key Laboratory of Multiscale Spin Physics (Ministry of Education), Beijing Normal UniversityBeijing, China
| | - Yaqiang Liu
- Department of Engineering Physics, Tsinghua UniversityBeijing, China
- Key Laboratory of Particle and Radiation Imaging (Tsinghua University), Ministry of EducationBeijing, China
| |
Collapse
|
2
|
Wang R, Zhang D, Hu Y, Lyu Z, Ma T. High-sensitivity cardiac SPECT system design with collimator-less interspaced mosaic-patterned scintillators. Front Med (Lausanne) 2023; 10:1145351. [PMID: 37448793 PMCID: PMC10336213 DOI: 10.3389/fmed.2023.1145351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 06/02/2023] [Indexed: 07/15/2023] Open
Abstract
Purpose Single-photon emission computed tomography (SPECT) is an important tool for myocardial perfusion imaging (MPI). Mechanical collimators cause the resolution-sensitivity trade-off in the existing cardiac SPECT systems, which hinders fast cardiac scan capability. In this work, we propose a novel collimator-less cardiac SPECT system with interspaced mosaic-patterned scintillators, aiming to significantly improve sensitivity and reduce scan time without trading-off image resolution. Methods We propose to assemble a collimator-less cardiac SPECT with 7 mosaic-patterned detector modules forming a half-ring geometry. The detector module consists of 10 blocks, each of which is assembled with 768 sparsely distributed scintillators with a size of 1.68 mm × 1.68 mm × 20 mm, forming a mosaic pattern in the trans-axial direction. Each scintillator bar contains 5 GAGG(Ce) scintillators and 5 optical-guide elements, forming a mosaic pattern in the axial direction. In the Monte Carlo simulations, the in-plane resolution and axial resolution are evaluated using a hot-rod phantom and 5 disk phantoms, respectively. We simulate a cardiac phantom that is placed in a water-filled cylinder and evaluate the image performance with different data acquisition time. We perform image reconstruction with the expectation-maximization algorithm using system matrices derived from the simulation of a uniform cylindrical source filling the field-of-view (FOV). Besides, a 2-D prototype system is designed to demonstrate the feasibility of the collimator-less imaging concept. Results In the simulation system, the sensitivity is 16.31% ± 8.85% in a 180 mm (Φ) × 100 mm (L) FOV. The 6-mm rods in the hot rod phantom and the 5-mm disks in the disk phantom are clearly separable. Satisfactory MPI image quality is achieved in the cardiac phantom study with an acquisition time of 30 s. In prototype experiments, the point sources with an 8 mm center-to-center distance are clearly separable at different positions across the FOV. Conclusion The study reveals a promising approach to high-sensitivity SPECT imaging without a heavy-metal collimator. In cardiac imaging, this approach opens the way to a very fast cardiac scan with good resolution. Further works are ongoing to build a practical 3-D imaging system based on the existing design.
Collapse
Affiliation(s)
- Rui Wang
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle and Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
- Institute for Precision Medicine, Tsinghua University, Beijing, China
| | - Debin Zhang
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle and Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
- Institute for Precision Medicine, Tsinghua University, Beijing, China
| | - Yifan Hu
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle and Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
- Institute for Precision Medicine, Tsinghua University, Beijing, China
| | - Zhenlei Lyu
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle and Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
- Institute for Precision Medicine, Tsinghua University, Beijing, China
| | - Tianyu Ma
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle and Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
- Institute for Precision Medicine, Tsinghua University, Beijing, China
| |
Collapse
|
3
|
Boschi A, Uccelli L, Marvelli L, Cittanti C, Giganti M, Martini P. Technetium-99m Radiopharmaceuticals for Ideal Myocardial Perfusion Imaging: Lost and Found Opportunities. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27041188. [PMID: 35208982 PMCID: PMC8877792 DOI: 10.3390/molecules27041188] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 02/06/2022] [Accepted: 02/08/2022] [Indexed: 02/07/2023]
Abstract
The favorable nuclear properties in combination with the rich coordination chemistry make technetium-99m the radioisotope of choice for the development of myocardial perfusion tracers. In the early 1980s, [99mTc]Tc-Sestamibi, [99mTc]Tc-Tetrofosmin, and [99mTc]Tc-Teboroxime were approved as commercial radiopharmaceuticals for myocardial perfusion imaging in nuclear cardiology. Despite its peculiar properties, the clinical use of [99mTc]Tc-Teboroxime was quickly abandoned due to its rapid myocardial washout. Despite their widespread clinical applications, both [99mTc]Tc-Sestamibi and [99mTc]Tc-Tetrofosmin do not meet the requirements of an ideal perfusion imaging agent due to their relatively low first-pass extraction fraction and high liver absorption. An ideal radiotracer for myocardial perfusion imaging should have a high myocardial uptake; a high and stable target-to-background ratio with low uptake in the lungs, liver, stomach during the image acquisition period; a high first-pass myocardial extraction fraction and very rapid blood clearance; and a linear relationship between radiotracer myocardial uptake and coronary blood flow. Although it is difficult to reconcile all these properties in a single tracer, scientific research in the field has always channeled its efforts in the development of molecules that are able to meet the characteristics of ideality as much as possible. This short review summarizes the developments in 99mTc myocardial perfusion tracers, which are able to fulfill hitherto unmet medical needs and serve a large population of patients with heart disease, and underlines their strengths and weaknesses, the lost and found opportunities thanks to the developments of the new ultrafast SPECT technologies.
Collapse
Affiliation(s)
- Alessandra Boschi
- Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara, Via L. Borsari, 46-44121 Ferrara, Italy;
- Correspondence: ; Tel.:+39-0532-455354
| | - Licia Uccelli
- Department of Translational Medicine, University of Ferrara, Via Fossato di Mortara, 70 c/o Viale Eliporto, 46-44121 Ferrara, Italy; (L.U.); (C.C.); (M.G.)
| | - Lorenza Marvelli
- Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara, Via L. Borsari, 46-44121 Ferrara, Italy;
| | - Corrado Cittanti
- Department of Translational Medicine, University of Ferrara, Via Fossato di Mortara, 70 c/o Viale Eliporto, 46-44121 Ferrara, Italy; (L.U.); (C.C.); (M.G.)
| | - Melchiore Giganti
- Department of Translational Medicine, University of Ferrara, Via Fossato di Mortara, 70 c/o Viale Eliporto, 46-44121 Ferrara, Italy; (L.U.); (C.C.); (M.G.)
| | - Petra Martini
- Department of Environmental and Prevention Sciences, University of Ferrara, Via L. Borsari, 46-44121 Ferrara, Italy;
| |
Collapse
|
4
|
Ritt P. Recent Developments in SPECT/CT. Semin Nucl Med 2022; 52:276-285. [DOI: 10.1053/j.semnuclmed.2022.01.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 01/18/2022] [Accepted: 01/18/2022] [Indexed: 01/31/2023]
|
5
|
Chaudhari AJ, Badawi RD. Application-specific nuclear medical in vivoimaging devices. Phys Med Biol 2021; 66:10TR01. [PMID: 33770765 DOI: 10.1088/1361-6560/abf275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 03/26/2021] [Indexed: 11/11/2022]
Abstract
Nuclear medical imaging devices, such as those enabling photon emission imaging (gamma camera, single photon emission computed tomography, or positron emission imaging), that are typically used in today's clinics are optimized for assessing large portions of the human body, and are classified as whole-body imaging systems. These systems have known limitations for organ imaging, therefore application-specific devices have been designed, constructed and evaluated. These devices, given their compact nature and superior technical characteristics, such as their higher detection sensitivity and spatial resolution for organ imaging compared to whole-body imaging systems, have shown promise for niche applications. Several of these devices have further been integrated with complementary anatomical imaging devices. The objectives of this review article are to (1) provide an overview of such application-specific nuclear imaging devices that were developed over the past two decades (in the twenty-first century), with emphasis on brain, cardiac, breast, and prostate imaging; and (2) discuss the rationale, advantages and challenges associated with the translation of these devices for routine clinical imaging. Finally, a perspective on the future prospects for application-specific devices is provided, which is that sustained effort is required both to overcome design limitations which impact their utility (where these exist) and to collect the data required to define their clinical value.
Collapse
Affiliation(s)
- Abhijit J Chaudhari
- Department of Radiology, University of California Davis, Sacramento, CA 95817, United States of America
- Center for Molecular and Genomic Imaging, University of California Davis, Davis, CA 95616, United States of America
| | - Ramsey D Badawi
- Department of Radiology, University of California Davis, Sacramento, CA 95817, United States of America
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616, United States of America
| |
Collapse
|
6
|
Duatti A. Review on 99mTc radiopharmaceuticals with emphasis on new advancements. Nucl Med Biol 2021; 92:202-216. [PMID: 32475681 DOI: 10.1016/j.nucmedbio.2020.05.005] [Citation(s) in RCA: 83] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Revised: 05/07/2020] [Accepted: 05/18/2020] [Indexed: 02/06/2023]
Abstract
Rapid imaging acquisition, high spatial resolution and sensitivity, powered by advancements in solid-state detector technology, are significantly changing the perspective of single photon emission tomography (SPECT). In particular, this evolutionary step is fueling a rediscovery of technetium-99m, a still unique radionuclide within the nuclear medicine scenario because of its ideal nuclear properties and easy preparation of its radiopharmaceuticals that does not require a costly infrastructure and complex procedures. Scope of this review is to show that the arsenal of technetium-99m radiopharmaceuticals is already equipped with imaging agents that may complement and integrate the role played by analogous tracers developed for positron emission tomography (PET). These include, in particular, somatostatin (SST) and prostate-specific membrane antigen (PSMA) receptor targeting agents, and a number of peptide-derived radiopharmaceuticals. Additionally, these recent technological developments, combined with new myocardial perfusion tracers having more favorable biodistribution and pharmacokinetic properties as compared to current commercial agents, may also reinvigorate the prevailing position still hold by technetium-99m radiopharmaceuticals in nuclear cardiology.
Collapse
Affiliation(s)
- Adriano Duatti
- Department of Chemical and Pharmaceutical Sciences, University of Ferrara, Ferrara, Italy.
| |
Collapse
|
7
|
Zhao M, Chen H, Yao M, Guo R, Xiao H. Experimental Study on Combustion Chamber Flow Field Using Positron Emission Tomography. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN 2020. [DOI: 10.1252/jcej.19we150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Min Zhao
- College of Automation Engineering, Nanjing University of Aeronautics and Astronautics
- Nondestructive Detection and Monitoring Technology for High Speed Transportation Facilities, Key Laboratory of Ministry of Industry and Information Technology
| | - Hao Chen
- College of Automation Engineering, Nanjing University of Aeronautics and Astronautics
- Nondestructive Detection and Monitoring Technology for High Speed Transportation Facilities, Key Laboratory of Ministry of Industry and Information Technology
| | - Min Yao
- College of Automation Engineering, Nanjing University of Aeronautics and Astronautics
- Nondestructive Detection and Monitoring Technology for High Speed Transportation Facilities, Key Laboratory of Ministry of Industry and Information Technology
| | - Ruipeng Guo
- College of Automation Engineering, Nanjing University of Aeronautics and Astronautics
- Nondestructive Detection and Monitoring Technology for High Speed Transportation Facilities, Key Laboratory of Ministry of Industry and Information Technology
| | - Hui Xiao
- College of Automation Engineering, Nanjing University of Aeronautics and Astronautics
- Nondestructive Detection and Monitoring Technology for High Speed Transportation Facilities, Key Laboratory of Ministry of Industry and Information Technology
| |
Collapse
|
8
|
Ng KS, Russo R, Gladman MA. Colonic transit in patients after anterior resection: prospective, comparative study using single-photon emission CT/CT scintigraphy. Br J Surg 2020; 107:567-579. [PMID: 32154585 DOI: 10.1002/bjs.11471] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 11/18/2019] [Accepted: 11/19/2019] [Indexed: 01/31/2023]
Abstract
BACKGROUND Bowel dysfunction after anterior resection is well documented, but its pathophysiology remains poorly understood. No study has assessed whether postoperative variation in colonic transit contributes to symptoms. This study measured colonic transit using planar scintigraphy and single-photon emission CT (SPECT)/CT in patients after anterior resection, stratified according to postoperative bowel function. METHODS Symptoms were assessed using the low anterior resection syndrome (LARS) score. Following gallium-67 ingestion, scintigraphy was performed at predefined time points. Nine regions of interest were defined, and geometric centre (GC), percentage isotope retained, GC velocity index and colonic half-clearance time (T½ ) determined. Transit parameters were compared between subgroups based on LARS score using receiver operating characteristic (ROC) curve analyses. RESULTS Fifty patients (37 men; median age 72·6 (range 44·4-87·7) years) underwent planar and SPECT scintigraphy. Overall, 17 patients had major and nine had minor LARS; 24 did not have LARS. There were significant differences in transit profiles between patients with major LARs and those without LARS: GCs were greater (median 5·94 (range 2·35-7·72) versus 4·30 (2·12-6·47) at 32 h; P = 0·015); the percentage retained isotope was lower (median 53·8 (range 6·5-100) versus 89·9 (38·4-100) per cent at 32 h; P = 0·002); GC velocity indices were greater (median 1·70 (range 1·18-1·92) versus 1·45 (0·98-1·80); P = 0·013); and T½ was shorter (median 38·3 (17·0-65·0) versus 57·0 (32·1-160·0) h; P = 0·003). Percentage tracer retained at 32 h best discriminated major LARS from no LARS (area under curve (AUC) 0·828). CONCLUSION Patients with major LARS had accelerated colonic transit compared with those without LARS, which may help explain postoperative bowel dysfunction in this group. The percentage tracer retained at 32 h had the greatest AUC value in discriminating such patients.
Collapse
Affiliation(s)
- K-S Ng
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
- Department of Nuclear Medicine, Specialist Colorectal and Pelvic Floor Centre, Sydney, New South Wales, Australia
| | - R Russo
- Department of Nuclear Medicine, Concord Hospital, Sydney, New South Wales, Australia
| | - M A Gladman
- Department of Nuclear Medicine, Specialist Colorectal and Pelvic Floor Centre, Sydney, New South Wales, Australia
- Adelaide Medical School, Faculty of Health and Medical Sciences, University of Adelaide, Adelaide, South Australia, Australia
| |
Collapse
|
9
|
Abstract
The continuous development of SPECT over the past 50 years has led to improved image quality and increased diagnostic confidence. The most influential developments include the realization of hybrid SPECT/CT devices, as well as the implementation of attenuation correction and iterative image reconstruction techniques. These developments have led to a preference for SPECT/CT devices over SPECT-only systems and to the widespread adoption of the former, strengthening the role of SPECT/CT as the workhorse of Nuclear Medicine imaging. New trends in the ongoing development of SPECT/CT are diverse. For example, whole-body SPECT/CT images, consisting of acquisitions from multiple consecutive bed positions in the manner of PET/CT, are increasingly performed. Additionally, in recent years, some interesting approaches in detector technology have found their way into commercial products. For example, some SPECT cameras dedicated to specific organs employ semiconductor detectors made of cadmium telluride or cadmium zinc telluride, which have been shown to increase the obtainable image quality by offering a higher sensitivity and energy resolution. However, the advent of quantitative SPECT/CT which, like PET, can quantify the amount of tracer in terms of Bq/mL or as a standardized uptake value could be regarded as most important development. It is a major innovation that will lead to increased diagnostic accuracy and confidence, especially in longitudinal studies and in the monitoring of treatment response. The current work comprises two main aspects. At first, physical and technical fundamentals of SPECT image formation are described and necessary prerequisites of quantitative SPECT/CT are reviewed. Additionally, the typically achievable quantitative accuracy based on reports from the literature is given. Second, an extensive list of studies reporting on clinical applications of quantitative SPECT/CT is provided and reviewed.
Collapse
Affiliation(s)
- Philipp Ritt
- Clinic of Nuclear Medicine, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.
| | - Torsten Kuwert
- Clinic of Nuclear Medicine, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
| |
Collapse
|
10
|
Eckelman WC, Kuwert T, Ciarmiello A, Riondato M, Mansi L. Changes over the years in radiopharmaceutical design. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2019; 66:261-271. [PMID: 31833739 DOI: 10.23736/s1824-4785.19.03216-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Of the many uses of radiopharmaceuticals, developing radiotracers that contribute significantly to diagnosis and therapy of patients has been a major focus. This requires a broad spectrum of expertise including that of the attending physician who lends insight to an unmet clinical need neither addressed by other imaging techniques nor by analysis of tissue, blood, and urine for diagnostics and addressed by pharmaceuticals for therapeutic applications. The design criteria have depended on radiochemistry, on matching the radiopharmaceutical with the imaging devices, and basing the design on current pharmaceuticals. The chelates of technetium-99m were based on radiochemistry rather than clinical need yet are still used today in >70% of the clinical studies. Targeted radiotracers in neurologic and psychiatric disorders, inflammation, cardiovascular disease, and oncology have all been studied with the goal of determining the change in the density of a target protein as a function of disease or treatment or, especially in oncology, detection of the total extent of disease. In latter approach PET in university settings leads the way; however, the use of SPECT/CT has increased the specificity of SPECT imaging to complement the cost- effective generator and instant kits already available. Remarkable advances has been achieved in radionuclide therapy using theragnostic agents, with the exclusive domain of oncology For this application the design of radionuclide therapy follows that used for diagnostics. The increased impact of the discipline depends on the opportunity to continue the search for the most appropriate radiopharmaceutical for each individual patient.
Collapse
Affiliation(s)
| | - Torsten Kuwert
- Clinic of Nuclear Medicine, University Hospital Erlangen, Erlangen, Germany
| | | | - Mattia Riondato
- Nuclear Medicine Unit, S. Andrea Hospital, La Spezia, Italy -
| | - Luigi Mansi
- Section Health and Development, Interuniversity Research Center for Sustainability (CIRPS), Napoli, Italy
| |
Collapse
|
11
|
Moncayo VM, Galt J. Attenuation correction in multipinhole-CZT gamma camera : Differences in attenuation pattern in myocardial SPECT between CZT and conventional gamma cameras. Oddstig J, Martinsson E, Jogi J, Engblom H, Hindorf C. J Nucl Cardiol. 2018. J Nucl Cardiol 2019; 26:1992-1995. [PMID: 30465233 DOI: 10.1007/s12350-018-01498-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Accepted: 10/15/2018] [Indexed: 10/27/2022]
Affiliation(s)
| | - James Galt
- Radiology and Imaging Sciences, Emory University, Atlanta, Georgia
| |
Collapse
|
12
|
Abbott BG, Case JA, Dorbala S, Einstein AJ, Galt JR, Pagnanelli R, Bullock-Palmer RP, Soman P, Wells RG. Contemporary Cardiac SPECT Imaging-Innovations and Best Practices: An Information Statement from the American Society of Nuclear Cardiology. Circ Cardiovasc Imaging 2019; 11:e000020. [PMID: 30354679 DOI: 10.1161/hci.0000000000000020] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Brian G Abbott
- Warren Alpert Medical School, Brown University, Providence, RI (B.G.A.)
| | - James A Case
- Cardiovascular Imaging Technologies, Kansas City, MO (J.A.C.)
| | - Sharmila Dorbala
- Harvard Medical School, Brigham and Women's Hospital, Boston, MA (S.D.)
| | - Andrew J Einstein
- Columbia University Irving Medical Center and New York-Presbyterian Hospital, New York, NY (A.J.E.)
| | - James R Galt
- Emory University School of Medicine, Atlanta, GA (J.R.G.)
| | | | | | - Prem Soman
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA (P.S.)
| | - R Glenn Wells
- University of Ottawa Heart Institute, Ottawa, Canada (R.G.W.)
| |
Collapse
|
13
|
Wei L, Petryk J, Gaudet C, Kamkar M, Gan W, Duan Y, Ruddy TD. Development of an inflammation imaging tracer, 111In-DOTA-DAPTA, targeting chemokine receptor CCR5 and preliminary evaluation in an ApoE -/- atherosclerosis mouse model. J Nucl Cardiol 2019; 26:1169-1178. [PMID: 29417414 DOI: 10.1007/s12350-018-1203-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Accepted: 01/17/2018] [Indexed: 11/26/2022]
Abstract
BACKGROUND Chemokine receptor 5 (CCR5) plays an important role in atherosclerosis. Our objective was to develop a SPECT tracer targeting CCR5 for imaging plaque inflammation by radiolabeling D-Ala-peptide T-amide (DAPTA), a CCR5 antagonist, with 111In. METHODS 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) conjugated DAPTA (DOTA-DAPTA) was labeled with 111In. Cell uptake studies were conducted in U87-CD4-CCR5 and U87-MG cells. Biodistribution was determined in C57BL/6 mice. Autoradiography, en face and Oil Red O (ORO) imaging studies were performed in ApoE-/- mice. RESULTS DOTA-DAPTA was radiolabeled with 111In with high radiochemical purity (> 98%) and specific activity (70 MBq·nmol). 111In-DOTA-DAPTA exhibited fast blood and renal clearance and high spleen uptake. The U87-CD4-CCR5 cells had significantly higher uptake in comparison to the U87-MG cells. The cell uptake was reduced by three times with DAPTA, indicating the receptor specificity of the uptake. Autoradiographic images showed significantly higher lesion uptake of 111In-DOTA-DAPTA in ApoE-/- mice than that in C57BL/6 mice. The tracer uptake in 4 month old ApoE-/- high fat diet (HFD) mice with blocking agent was twofold lower than the same mice without the blocking agent, demonstrating the specificity of the tracer for the CCR5 receptor. CONCLUSION 111In-DOTA-DAPTA, specifically targeting chemokine receptor CCR5, is a potential SPECT agent for imaging inflammation in atherosclerosis.
Collapse
Affiliation(s)
- Lihui Wei
- Nordion Inc., 447 March Road, Ottawa, ON, K2K 1X8, Canada.
- Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada.
- Nordion Lab, Canadian Molecular Imaging Center of Excellence (C-MICE), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada.
| | - Julia Petryk
- Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
- Nordion Lab, Canadian Molecular Imaging Center of Excellence (C-MICE), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
| | - Chantal Gaudet
- Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
| | - Maryam Kamkar
- Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
| | - Wei Gan
- Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
- Nordion Lab, Canadian Molecular Imaging Center of Excellence (C-MICE), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
| | - Yin Duan
- Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
- Nordion Lab, Canadian Molecular Imaging Center of Excellence (C-MICE), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
| | - Terrence D Ruddy
- Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
- Nordion Lab, Canadian Molecular Imaging Center of Excellence (C-MICE), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
| |
Collapse
|
14
|
Massalha S, Almufleh A, Small G, Marvin B, Keidar Z, Israel O, Kennedy JA. Strategies for Minimizing Occupational Radiation Exposure in Cardiac Imaging. Curr Cardiol Rep 2019; 21:71. [PMID: 31227929 DOI: 10.1007/s11886-019-1157-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE OF REVIEW Radiation safety has been at the center of interest of both researchers and healthcare institutions. This review will summarize and shed light on the various techniques adapted to reduce staff exposure to ionizing radiation (IR) in the field of cardiac imaging. RECENT FINDINGS In the last years, with the advance of awareness and the development of new technologies, there have been several tools and techniques adapted. The breakthrough of several technologies to lower radiation dose and shorten the duration of diagnostic tests associated with IR, the use of protection devices by staff members, and mostly the awareness of exposure to IR are the hallmark of these advances. Using all these measures has led to a significant decrease in staff exposure to IR. Reducing staff exposure to meet the "As Low As Reasonably Achievable" principle is feasible. This review introduces the most important strategies applied in cardiac imaging.
Collapse
Affiliation(s)
- Samia Massalha
- Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario, K1Y 4W7, Canada. .,Department of Cardiology, Rambam Health Care Campus, Haifa, Israel. .,Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel.
| | - Aws Almufleh
- Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario, K1Y 4W7, Canada
| | - Garry Small
- Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario, K1Y 4W7, Canada
| | - Brian Marvin
- Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario, K1Y 4W7, Canada
| | - Zohar Keidar
- Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel
| | - Ora Israel
- Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel.,Rappaport Faculty of Medicine, Technion - Israel Institute of Technology, Haifa, Israel
| | - John A Kennedy
- Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel.,Faculty of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
15
|
Juárez-Orozco LE, Tio RA, Alexanderson E, Dweck M, Vliegenthart R, El Moumni M, Prakken N, Gonzalez-Godinez I, Slart RHJA. Quantitative myocardial perfusion evaluation with positron emission tomography and the risk of cardiovascular events in patients with coronary artery disease: a systematic review of prognostic studies. Eur Heart J Cardiovasc Imaging 2019; 19:1179-1187. [PMID: 29293983 PMCID: PMC6148746 DOI: 10.1093/ehjci/jex331] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Accepted: 12/05/2017] [Indexed: 01/05/2023] Open
Abstract
Aims To evaluate the prognostic value of quantitative myocardial perfusion imaging with positron emission tomography (PET) for adverse cardiovascular outcomes in patients with known or suspected coronary artery disease (CAD). Methods and results A search in MEDLINE and Embase was conducted for studies that evaluated (i) myocardial perfusion in absolute terms with PET, (ii) prognostic value for the development of major adverse cardiovascular events (MACE), cardiac death, and/or all-cause mortality, and (iii) patients with known or suspected CAD. Studies were divided according to the radiotracer utilized and their included population (patients with and without previous infarction). Comprehensive description and a selected instance of pooling were performed. Eight studies (n = 6804) were analysed and documented clear variability in population, quantitative PET variables operationalization [stress myocardial blood flow (sMBF) and flow reserve (MFR)], statistical covariate structure, follow-up, and radiotracer utilized. MFR was independently associated with MACE in eight studies [range of adjusted hazard ratios (HRs): 1.19–2.93]. The pooling instance demonstrated that MFR significantly associates with the development of MACEs (HR: 1.92 [1.29, 2.84]; P = 0.001). sMBF was only associated with MACE in two studies that evaluated it, and only one study documented sMBF as a better predictor than MFR. Conclusion This systematic review demonstrates the prognostic value of quantitative myocardial perfusion evaluated with PET, in the form of MFR and sMBF, for the development of major adverse cardiovascular outcomes in populations with known or suspected CAD. In the qualitative comparison, MFR seems to outperform sMBF as an independent prognostic factor. Evidence is still lacking for assessing quantitative PET for the occurrence of cardiac death and all-cause mortality. There is clear heterogeneity in predictor operationalization and study performances.
Collapse
Affiliation(s)
- Luis Eduardo Juárez-Orozco
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, Internal Postcode: EB50, 9700 RB, Groningen, The Netherlands
| | - Rene A Tio
- Department of Cardiology, Catharina Hospital, Michelangelolaan 2, EJ, Eindhoven, The Netherlands
| | - Erick Alexanderson
- Department of Nuclear Cardiology, Instituto Nacional de Cardiología "Ignacio Chávez", Juan Badiano 1, Belisario Domínguez Secc 16, Tlalpan, CDMX, Mexico
| | - Marc Dweck
- British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Little France Crescent, Edinburgh, UK
| | - Rozemarijn Vliegenthart
- Department of Radiology, University Medical Center Groningen, Center for Medical Imaging, University of Groningen, Hanzeplein 1 UMCG, RB, Groningen, The Netherlands
| | - Mostafa El Moumni
- Department of Traumatology, University Medical Center Groningen, University of Groningen, Hanzeplein 1 UMCG, 9700RB, Groningen, The Netherlands
| | - Niek Prakken
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, Internal Postcode: EB50, 9700 RB, Groningen, The Netherlands
| | - Ivan Gonzalez-Godinez
- Department of Internal Medicine, Dalinde Medical Center, Tuxpan 25, Colonia Roma, C.P. CDMX, Mexico
| | - Riemer H J A Slart
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Hanzeplein 1, Internal Postcode: EB50, 9700 RB, Groningen, The Netherlands.,Department of Biomedical Photonic Imaging Group, University of Twente, Zuidhorst ZH164 Dienstweg 1, ND, Enschede, The Netherlands
| |
Collapse
|
16
|
Abstract
Cardiac SPECT continues to play a critical role in detecting and managing cardiovascular disease, in particularly coronary artery disease (CAD) (Jaarsma et al 2012 J. Am. Coll. Cardiol. 59 1719-28), (Agostini et al 2016 Eur. J. Nucl. Med. Mol. Imaging 43 2423-32). While conventional dual-head SPECT scanners using parallel-hole collimators and scintillation crystals with photomultiplier tubes are still the workhorse of cardiac SPECT, they have the limitations of low photon sensitivity (~130 count s-1 MBq-1), poor image resolution (~15 mm) (Imbert et al 2012 J. Nucl. Med. 53 1897-903), relatively long acquisition time, inefficient use of the detector, high radiation dose, etc. Recently our field observed an exciting growth of new developments of dedicated cardiac scanners and collimators, as well as novel imaging algorithms for quantitative cardiac SPECT. These developments have opened doors to new applications with potential clinical impact, including ultra-low-dose imaging, absolute quantification of myocardial blood flow (MBF) and coronary flow reserve (CFR), multi-radionuclide imaging, and improved image quality as a result of attenuation, scatter, motion, and partial volume corrections (PVCs). In this article, we review the recent advances in cardiac SPECT instrumentation and imaging methods. This review mainly focuses on the most recent developments published since 2012 and points to the future of cardiac SPECT from an imaging physics perspective.
Collapse
Affiliation(s)
- Jing Wu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, United States of America
| | | |
Collapse
|
17
|
Salvarese N, Carta D, Marzano C, Gerardi G, Melendez-Alafort L, Bolzati C. [99mTc][Tc(N)(DASD)(PNPn)]+ (DASD = 1,4-Dioxa-8-azaspiro[4,5]decandithiocarbamate, PNPn = Bisphosphinoamine) for Myocardial Imaging: Synthesis, Pharmacological and Pharmacokinetic Studies. J Med Chem 2018; 61:11114-11126. [DOI: 10.1021/acs.jmedchem.8b01191] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Nicola Salvarese
- Institute of Condensed Matter Chemistry and Technologies for Energy (ICMATE)-CNR, Corso Stati Uniti, 4, 35127 Padova, Italy
| | - Davide Carta
- Department of Pharmaceutical and Pharmacological Sciences, University of Padua, Via Marzolo, 5, 35131 Padova, Italy
| | - Cristina Marzano
- Department of Pharmaceutical and Pharmacological Sciences, University of Padua, Via Marzolo, 5, 35131 Padova, Italy
| | - Gabriele Gerardi
- Department of Veterinary Clinical Science, University of Padua, Viale dell’Università 16, 35020 Legnaro, Padua, Italy
| | | | - Cristina Bolzati
- Institute of Condensed Matter Chemistry and Technologies for Energy (ICMATE)-CNR, Corso Stati Uniti, 4, 35127 Padova, Italy
| |
Collapse
|
18
|
Abbott BG, Case JA, Dorbala S, Einstein AJ, Galt JR, Pagnanelli R, Bullock-Palmer RP, Soman P, Wells RG. Contemporary Cardiac SPECT Imaging-Innovations and Best Practices: An Information Statement from the American Society of Nuclear Cardiology. J Nucl Cardiol 2018; 25:1847-1860. [PMID: 30143954 DOI: 10.1007/s12350-018-1348-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
This information statement from the American Society of Nuclear Cardiology highlights advances in cardiac SPECT imaging and supports the incorporation of new technology and techniques in laboratories performing nuclear cardiology procedures. The document focuses on the application of the latest imaging protocols and the utilization of newer hardware and software options to perform high quality, state-of-the-art SPECT nuclear cardiology procedures. Recommendations for best practices of cardiac SPECT imaging are discussed, highlighting what imaging laboratories should be doing as the standard of care in 2018 to achieve optimal results (based on the ASNC 2018 SPECT guideline [Dorbala et al., J Nucl Cardiol. 2018. https://doi.org/10.1007/s12350-018-1283-y ]).
Collapse
Affiliation(s)
- Brian G Abbott
- Warren Alpert Medical School, Brown University, Providence, RI, USA.
| | - James A Case
- Cardiovascular Imaging Technologies, Kansas City, MO, USA
| | - Sharmila Dorbala
- Harvard Medical School, Brigham and Women's Hospital, Boston, MA, USA
| | - Andrew J Einstein
- Columbia University Irving Medical Center and New York-Presbyterian Hospital, New York, NY, USA
| | - James R Galt
- Emory University School of Medicine, Atlanta, GA, USA
| | | | | | - Prem Soman
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - R Glenn Wells
- University of Ottawa Heart Institute, Ottawa, Canada
| |
Collapse
|
19
|
Galt JR. New techniques, distinctive population, unique normal databases. J Nucl Cardiol 2018; 25:1338-1341. [PMID: 28474193 DOI: 10.1007/s12350-017-0876-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Accepted: 03/27/2017] [Indexed: 10/19/2022]
Affiliation(s)
- James R Galt
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1364 Clifton Road, Atlanta, Georgia, 30322, USA.
| |
Collapse
|
20
|
Gutstein A, Bental T, Solodky A, Mats I, Zafrir N. Prognosis of stress-only SPECT myocardial perfusion imaging with prone imaging. J Nucl Cardiol 2018; 25:809-816. [PMID: 27671493 DOI: 10.1007/s12350-016-0617-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 06/16/2016] [Indexed: 11/28/2022]
Abstract
BACKGROUND Stress-only single-photon emission computed tomography myocardial perfusion imaging (SO SPECT MPI) is associated with similarly benign prognosis as stress-rest SPECT MPI. However, previous studies have used attenuation correction rather than prone imaging to increase the rate of SO studies. OBJECTIVES To assess the prognosis of SO SPECT MPI performed with prone imaging. METHODS We performed a retrospective cohort analysis of all patients who underwent a Tc-99m gated SPECT MPI over a 58-month period. RESULTS Two thousand four hundred and sixty five patients were followed up. Of them, 1114 (45.2%) patients had a SO supine test, 388 (15.7%) underwent a SO supine and prone test, and the remaining 963 (39.1%) patients underwent a full stress-rest SPECT MPI. There was a similar annual mortality rate between the SO supine/prone group (1.3%), the SO supine (1.5%), and the stress-rest (1.5%) group (P = 0.47). Patients in the stress-rest group were significantly more likely to suffer from myocardial infarction (MI) as compared to the other two groups with an annual rate of 0.7% as compared to 0.4% (P = 0.049). CONCLUSIONS Normal supine-prone SO SPECT MPI is associated with a similarly benign prognosis as stress-rest SPECT MPI. The adjunction of prone imaging to the stress supine significantly increases the rate of SO SPECT MPI.
Collapse
Affiliation(s)
- Ariel Gutstein
- Rabin Medical Center, Tel-Aviv University, Petach Tikva, Israel.
| | - Tamir Bental
- Rabin Medical Center, Tel-Aviv University, Petach Tikva, Israel
| | | | - Israel Mats
- Rabin Medical Center, Tel-Aviv University, Petach Tikva, Israel
| | - Nili Zafrir
- Rabin Medical Center, Tel-Aviv University, Petach Tikva, Israel.
| |
Collapse
|
21
|
Mannheim JG, Schmid AM, Schwenck J, Katiyar P, Herfert K, Pichler BJ, Disselhorst JA. PET/MRI Hybrid Systems. Semin Nucl Med 2018; 48:332-347. [PMID: 29852943 DOI: 10.1053/j.semnuclmed.2018.02.011] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Over the last decade, the combination of PET and MRI in one system has proven to be highly successful in basic preclinical research, as well as in clinical research. Nowadays, PET/MRI systems are well established in preclinical imaging and are progressing into clinical applications to provide further insights into specific diseases, therapeutic assessments, and biological pathways. Certain challenges in terms of hardware had to be resolved concurrently with the development of new techniques to be able to reach the full potential of both combined techniques. This review provides an overview of these challenges and describes the opportunities that simultaneous PET/MRI systems can exploit in comparison with stand-alone or other combined hybrid systems. New approaches were developed for simultaneous PET/MRI systems to correct for attenuation of 511 keV photons because MRI does not provide direct information on gamma photon attenuation properties. Furthermore, new algorithms to correct for motion were developed, because MRI can accurately detect motion with high temporal resolution. The additional information gained by the MRI can be employed to correct for partial volume effects as well. The development of new detector designs in combination with fast-decaying scintillator crystal materials enabled time-of-flight detection and incorporation in the reconstruction algorithms. Furthermore, this review lists the currently commercially available systems both for preclinical and clinical imaging and provides an overview of applications in both fields. In this regard, special emphasis has been placed on data analysis and the potential for both modalities to evolve with advanced image analysis tools, such as cluster analysis and machine learning.
Collapse
Affiliation(s)
- Julia G Mannheim
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Andreas M Schmid
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Johannes Schwenck
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Tuebingen, Germany; Department of Nuclear Medicine and Clinical Molecular Imaging, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Prateek Katiyar
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Kristina Herfert
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Bernd J Pichler
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Tuebingen, Germany.
| | - Jonathan A Disselhorst
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Tuebingen, Germany
| |
Collapse
|
22
|
Maddahi J, Packard RRS. PET should replace SPECT in cardiac imaging for diagnosis and risk assessment of patients with known or suspected CAD: Pro. J Nucl Cardiol 2017; 24:1955-1959. [PMID: 28397181 DOI: 10.1007/s12350-015-0300-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2015] [Accepted: 09/23/2015] [Indexed: 11/25/2022]
Affiliation(s)
- Jamshid Maddahi
- Department of Medicine (Cardiology), Ronald Reagan UCLA Medical Center, University of California at Los Angeles (UCLA) School of Medicine, Los Angeles, CA, USA.
- Department of Molecular and Medical Pharmacology (Nuclear Medicine), Ronald Reagan UCLA Medical Center, University of California at Los Angeles (UCLA) School of Medicine, 100 Medical Plaza, Suite 410, Los Angeles, CA, 90095, USA.
| | - René R Sevag Packard
- Department of Medicine (Cardiology), Ronald Reagan UCLA Medical Center, University of California at Los Angeles (UCLA) School of Medicine, Los Angeles, CA, USA
| |
Collapse
|
23
|
Nekolla SG, van Marwick S, Schachoff S, Kunze KP, Rischpler C. Cardiovascular PET/MRI: Technical Considerations and Outlook. CURRENT CARDIOVASCULAR IMAGING REPORTS 2017. [DOI: 10.1007/s12410-017-9435-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
24
|
Pascual TNB, Mercuri M, El-Haj N, Bom HHS, Lele V, Al-Mallah MH, Luxenburg O, Karthikeyan G, Vitola J, Mahmarian JJ, Better N, Shaw LJ, Rehani MM, Kashyap R, Paez D, Dondi M, Einstein AJ. Nuclear Cardiology Practice in Asia: Analysis of Radiation Exposure and Best Practice for Myocardial Perfusion Imaging - Results From the IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS). Circ J 2017; 81:501-510. [PMID: 28179594 DOI: 10.1253/circj.cj-16-0677] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2025]
Abstract
BACKGROUND This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia. METHODS AND RESULTS Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. CONCLUSIONS MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care.
Collapse
Affiliation(s)
- Thomas N B Pascual
- Section of Nuclear Medicine and Diagnostic Imaging, Division of Human Health, International Atomic Energy Agency
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Slomka P, Hung GU, Germano G, Berman DS. Novel SPECT Technologies and Approaches in Cardiac Imaging. CARDIOVASCULAR INNOVATIONS AND APPLICATIONS 2016; 2:31-46. [PMID: 29034066 PMCID: PMC5640436 DOI: 10.15212/cvia.2016.0052] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Recent novel approaches in myocardial perfusion single photon emission CT (SPECT) have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv) stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.
Collapse
Affiliation(s)
- Piotr Slomka
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Guang-Uei Hung
- Department of Nuclear Medicine, Chang Bing Show Chwan Memorial Hospital, Changhua, Taiwan
| | - Guido Germano
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Daniel S. Berman
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| |
Collapse
|
26
|
Brodov Y, Fish M, Rubeaux M, Otaki Y, Gransar H, Lemley M, Gerlach J, Berman D, Germano G, Slomka P. Quantitation of left ventricular ejection fraction reserve from early gated regadenoson stress Tc-99m high-efficiency SPECT. J Nucl Cardiol 2016; 23:1251-1261. [PMID: 27387521 PMCID: PMC5116262 DOI: 10.1007/s12350-016-0519-y] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Accepted: 04/07/2016] [Indexed: 11/30/2022]
Abstract
BACKGROUND Ejection fraction (EF) reserve has been found to be a useful adjunct for identifying high risk coronary artery disease in cardiac positron emission tomography (PET). We aimed to evaluate EF reserve obtained from technetium-99m sestamibi (Tc-99m) high-efficiency (HE) SPECT. METHODS Fifty patients (mean age 69 years) undergoing regadenoson same-day rest (8-11 mCi)/stress (32-42 mCi) Tc-99m gated HE SPECT were enrolled. Stress imaging was started 1 minute after sequential intravenous regadenoson .4 mg and Tc-99m injections, and was composed of five 2 minutes supine gated acquisitions followed by two 4 minutes supine and upright images. Ischemic total perfusion deficit (ITPD) ≥5 % was considered as significant ischemia. RESULTS Significantly lower mean EF reserve was obtained in the 5th and 9th minute after regadenoson bolus in patients with significant ischemia vs patients without (5th minute: -4.2 ± 4.6% vs 1.3 ± 6.6%, P = .006; 9th minute: -2.7 ± 4.8% vs 2.0 ± 6.6%, P = .03). CONCLUSIONS Negative EF reserve obtained between 5th and 9th minutes of regadenoson stress demonstrated best concordance with significant ischemia and may be a promising tool for detection of transient ischemic functional changes with Tc-99m HE-SPECT.
Collapse
Affiliation(s)
- Yafim Brodov
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Mathews Fish
- Nuclear Medicine Department, Oregon Heart and Vascular Institute, Sacred Heart Medical Center, Springfield, OR, USA
| | - Mathieu Rubeaux
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Yuka Otaki
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Heidi Gransar
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Mark Lemley
- Nuclear Medicine Department, Oregon Heart and Vascular Institute, Sacred Heart Medical Center, Springfield, OR, USA
| | - Jim Gerlach
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Daniel Berman
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
- David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, USA
| | - Guido Germano
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
- David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, USA
| | - Piotr Slomka
- Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
- David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
27
|
Tamaki N. New PET system permits reliable estimates of myocardial blood flow and flow reserve. J Nucl Cardiol 2016; 23:473-4. [PMID: 25802177 DOI: 10.1007/s12350-015-0098-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2015] [Accepted: 02/09/2015] [Indexed: 11/29/2022]
Affiliation(s)
- Nagara Tamaki
- Department of Nuclear Medicine, Hokkaido University Graduate School of Medicine, N-15, W-7, Kita ku, Sapporo, 060-8638, Japan.
| |
Collapse
|
28
|
Mao Y, Yu Z, Zeng GL. Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations. Med Phys 2016; 42:5426-34. [PMID: 26328991 DOI: 10.1118/1.4928484] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue in building a stationary system is to provide sufficient projection view-angles. METHODS A GATE (GEANT4 application for tomographic emission) Monte Carlo model was developed to simulate a two-detector stationary cardiac SPECT that uses segmented slant-hole collimators. Each detector contains seven segmented slant-hole sections that slant to a common volume at the rotation center. Consequently, 14 view-angles over 180° were acquired without any gantry rotation. The NCAT phantom was used for data generation and a tailored maximum-likelihood expectation-maximization algorithm was used for image reconstruction. Effects of limited number of view-angles and data truncation were carefully evaluated in the paper. RESULTS Simulation results indicated that the proposed segmented slant-hole stationary cardiac SPECT system is able to acquire sufficient data for cardiac imaging without a loss of image quality, even when the uptakes in the liver and kidneys are high. Seven views are acquired simultaneously at each detector, leading to 5-fold sensitivity gain over the conventional dual-head system at the same total acquisition time, which in turn increases the signal-to-noise ratio by 19%. The segmented slant-hole SPECT system also showed a good performance in lesion detection. In our prototype system, a short hole-length was used to reduce the dead zone between neighboring collimator segments. The measured sensitivity gain is about 17-fold over the conventional dual-head system. CONCLUSIONS The gate Monte Carlo simulations confirm the feasibility of the proposed stationary cardiac SPECT system with segmented slant-hole collimators. The proposed collimator consists of combined parallel and slant holes, and the image on the detector is not reduced in size.
Collapse
Affiliation(s)
- Yanfei Mao
- Department of Radiology, Utah Center for Advanced Imaging Research (UCAIR), University of Utah, Salt Lake City, Utah 84108 and Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112
| | - Zhicong Yu
- Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905
| | - Gengsheng L Zeng
- Department of Radiology, Utah Center for Advanced Imaging Research (UCAIR), University of Utah, Salt Lake City, Utah 84108 and Department of Engineering, Weber State University, Ogden, Utah 84408
| |
Collapse
|
29
|
Roy UN, Mundle RM, Camarda GS, Cui Y, Gul R, Hossain A, Yang G, Pradhan AK, James RB. Novel ZnO:Al contacts to CdZnTe for X- and gamma-ray detectors. Sci Rep 2016; 6:26384. [PMID: 27216387 PMCID: PMC4877641 DOI: 10.1038/srep26384] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2016] [Accepted: 04/29/2016] [Indexed: 11/09/2022] Open
Abstract
CdZnTe (CZT) has made a significant impact as a material for room-temperature nuclear-radiation detectors due to its potential impact in applications related to nonproliferation, homeland security, medical imaging, and gamma-ray telescopes. In all such applications, common metals, such as gold, platinum and indium, have been used as electrodes for fabricating the detectors. Because of the large mismatch in the thermal-expansion coefficient between the metal contacts and CZT, the contacts can undergo stress and mechanical degradation, which is the main cause for device instability over the long term. Here, we report for the first time on our use of Al-doped ZnO as the preferred electrode for such detectors. The material was selected because of its better contact properties compared to those of the metals commonly used today. Comparisons were conducted for the detector properties using different contacts, and improvements in the performances of ZnO:Al-coated detectors are described in this paper. These studies show that Al:ZnO contacts to CZT radiation detectors offer the potential of becoming a transformative replacement for the common metallic contacts due to the dramatic improvements in the performance of detectors and improved long-term stability.
Collapse
Affiliation(s)
- U N Roy
- Brookhaven National Laboratory, Upton, NY 11973, United States
| | - R M Mundle
- Department of Engineering, Norfolk State University, Norfolk, VA 23504, United States
| | - G S Camarda
- Brookhaven National Laboratory, Upton, NY 11973, United States
| | - Y Cui
- Brookhaven National Laboratory, Upton, NY 11973, United States
| | - R Gul
- Brookhaven National Laboratory, Upton, NY 11973, United States
| | - A Hossain
- Brookhaven National Laboratory, Upton, NY 11973, United States
| | - G Yang
- Brookhaven National Laboratory, Upton, NY 11973, United States
| | - A K Pradhan
- Department of Engineering, Norfolk State University, Norfolk, VA 23504, United States
| | - R B James
- Brookhaven National Laboratory, Upton, NY 11973, United States
| |
Collapse
|
30
|
Allie R, Hutton BF, Prvulovich E, Bomanji J, Michopoulou S, Ben-Haim S. Pitfalls and artifacts using the D-SPECT dedicated cardiac camera. J Nucl Cardiol 2016; 23:301-10. [PMID: 26403143 DOI: 10.1007/s12350-015-0277-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Accepted: 07/28/2015] [Indexed: 11/28/2022]
Abstract
Myocardial perfusion imaging is a well-established and widely used imaging technique for the assessment of patients with known or suspected coronary artery disease. Pitfalls and artifacts associated with conventional gamma cameras are well known, and the ways to avoid and correct them have been described. In recent years solid-state detector dedicated cardiac cameras were introduced and have been shown to offer improved accuracy in addition to new imaging protocols and novel applications. The purpose of this manuscript is to familiarize the readers with the causes and effects of technical, patient-related, and operator-related pitfalls and artifacts associated with the D-SPECT dedicated cardiac camera with solid-state detectors. The manuscript offers guidance on how to avoid these factors, how to detect them, and how to correct better for them, providing high-quality diagnostic images.
Collapse
Affiliation(s)
- Rayjanah Allie
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
| | - Brian F Hutton
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
| | - Elizabeth Prvulovich
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
| | - Jamshed Bomanji
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
| | - Sofia Michopoulou
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom
| | - Simona Ben-Haim
- Institute of Nuclear Medicine, University College London and UCL Hospitals, NHS Trust, London, United Kingdom.
- Institute of Nuclear Medicine, Chaim Sheba Medical Center, Tel-Hashomer, 5265601, Israel.
| |
Collapse
|
31
|
Vancraeynest D, Roelants V, Bouzin C, Hanin FX, Walrand S, Bol V, Bol A, Pouleur AC, Pasquet A, Gerber B, Lesnik P, Huby T, Jamar F, Vanoverschelde JL. αVβ3 integrin-targeted microSPECT/CT imaging of inflamed atherosclerotic plaques in mice. EJNMMI Res 2016; 6:29. [PMID: 27009066 PMCID: PMC4805679 DOI: 10.1186/s13550-016-0184-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Accepted: 03/15/2016] [Indexed: 12/11/2022] Open
Abstract
Background αVβ3-integrin is expressed by activated endothelial cells and macrophages in atherosclerotic plaques and may represent a valuable marker of high-risk plaques. We evaluated 99mTc-maraciclatide, an integrin-specific tracer, for imaging vascular inflammation in atherosclerotic lesions in mice. Methods Apolipoprotein E-negative (ApoE−/−) mice on a Western diet (n = 10) and normally fed adult C57BL/6 control mice (n = 4) were injected with 99mTc-maraciclatide (51.8 ± 3.7 MBq). A blocking peptide was infused in three ApoE−/− mice; this condition served as another control. After 90 min, the animals were imaged via single-photon emission computed tomography (SPECT). While maintained in the same position, the mice were transferred to computed tomography (CT) to obtain contrast-enhanced images of the aortic arch. Images from both modalities were fused, and signal was quantified in the aortic arch and in the vena cava for subtraction of blood-pool activity. The aorta was carefully dissected after imaging for gamma counting, autoradiography, and histology. Results Tracer uptake was significantly higher in ApoE−/− mice than in both groups of control mice (1.56 ± 0.33 vs. 0.82 ± 0.24 vs. 0.98 ± 0.11, respectively; P = 0.006). Furthermore, higher tracer activity was detected via gamma counting in the aorta of hypercholesterolemic mice than in both groups of control mice (1.52 ± 0.43 vs. 0.78 ± 0.19 vs. 0.47 ± 0.31 99mTc-maraciclatide %ID/g, respectively; P = 0.018). Autoradiography showed significantly higher tracer uptake in the atherosclerotic aorta than in the control aorta (P = 0.026). Finally, in the atherosclerotic aorta, immunostaining indicated that the integrin signal came predominantly from macrophages and was correlated with the macrophage CD68 immunomarker (r = 0.73). Conclusions 99mTc-maraciclatide allows in vivo detection of inflamed atherosclerotic plaques in mice and may represent a non-invasive approach for identifying high-risk plaques in patients.
Collapse
Affiliation(s)
- David Vancraeynest
- Pôle de Recherche Cardiovasculaire (CARD), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium. .,Division of Cardiology, Cliniques Universitaires St-Luc, Avenue Hippocrate, 10-2881, B-1200, Brussels, Belgium.
| | - Véronique Roelants
- Pôle d'Imagerie Médicale, Radiothérapie et Oncologie (MIRO), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium
| | - Caroline Bouzin
- IREC Imaging Platform, Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium
| | - François-Xavier Hanin
- Pôle d'Imagerie Médicale, Radiothérapie et Oncologie (MIRO), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium
| | - Stephan Walrand
- Pôle d'Imagerie Médicale, Radiothérapie et Oncologie (MIRO), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium
| | - Vanesa Bol
- Pôle d'Imagerie Médicale, Radiothérapie et Oncologie (MIRO), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium
| | - Anne Bol
- Pôle d'Imagerie Médicale, Radiothérapie et Oncologie (MIRO), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium
| | - Anne-Catherine Pouleur
- Pôle de Recherche Cardiovasculaire (CARD), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium.,Division of Cardiology, Cliniques Universitaires St-Luc, Avenue Hippocrate, 10-2881, B-1200, Brussels, Belgium
| | - Agnès Pasquet
- Pôle de Recherche Cardiovasculaire (CARD), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium.,Division of Cardiology, Cliniques Universitaires St-Luc, Avenue Hippocrate, 10-2881, B-1200, Brussels, Belgium
| | - Bernhard Gerber
- Pôle de Recherche Cardiovasculaire (CARD), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium.,Division of Cardiology, Cliniques Universitaires St-Luc, Avenue Hippocrate, 10-2881, B-1200, Brussels, Belgium
| | - Philippe Lesnik
- INSERM UMR_S 1166, Integrative Biology of Atherosclerosis Team, Université Pierre et Marie Curie-Paris6 and institute of Cardiometabolism and Nutrition (ICAN), Pitié-Salpêtrière Hospital, 75013, Paris, France
| | - Thierry Huby
- INSERM UMR_S 1166, Integrative Biology of Atherosclerosis Team, Université Pierre et Marie Curie-Paris6 and institute of Cardiometabolism and Nutrition (ICAN), Pitié-Salpêtrière Hospital, 75013, Paris, France
| | - François Jamar
- Pôle d'Imagerie Médicale, Radiothérapie et Oncologie (MIRO), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium
| | - Jean-Louis Vanoverschelde
- Pôle de Recherche Cardiovasculaire (CARD), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium.,Division of Cardiology, Cliniques Universitaires St-Luc, Avenue Hippocrate, 10-2881, B-1200, Brussels, Belgium
| |
Collapse
|
32
|
Polte CL, Burck I, Gjertsson P, Lomsky M, Nekolla SG, Nagel E. Cardiac Positron Emission Tomography: a Clinical Perspective. CURRENT CARDIOVASCULAR IMAGING REPORTS 2016. [DOI: 10.1007/s12410-016-9371-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
33
|
Ben Bouallègue F, Roubille F, Lattuca B, Cung TT, Macia JC, Gervasoni R, Leclercq F, Mariano-Goulart D. SPECT Myocardial Perfusion Reserve in Patients with Multivessel Coronary Disease: Correlation with Angiographic Findings and Invasive Fractional Flow Reserve Measurements. J Nucl Med 2015; 56:1712-7. [DOI: 10.2967/jnumed.114.143164] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Accepted: 08/10/2015] [Indexed: 11/16/2022] Open
|
34
|
Prior JO. How much shorter is better? Investigating image acquisition time reduction on left ventricular phase analysis for cardiac dyssynchrony. J Nucl Cardiol 2015; 22:652-4. [PMID: 26071115 DOI: 10.1007/s12350-015-0196-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2015] [Accepted: 06/01/2015] [Indexed: 10/23/2022]
Affiliation(s)
- John O Prior
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Rue du Bugnon 46, 1011, Lausanne, Switzerland,
| |
Collapse
|
35
|
Is Attenuation Correction for Myocardial Perfusion Imaging Underutilized? CURRENT CARDIOVASCULAR IMAGING REPORTS 2015. [DOI: 10.1007/s12410-015-9346-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
36
|
Alexanderson-Rosas E, Guinto-Nishimura GY, Cruz-Mendoza JR, Oropeza-Aguilar M, De La Fuente-Mancera JC, Barrero-Mier AF, Monroy-Gonzalez A, Juarez-Orozco LE, Cano-Zarate R, Meave-Gonzalez A. Current and future trends in multimodality imaging of coronary artery disease. Expert Rev Cardiovasc Ther 2015; 13:715-31. [PMID: 25912725 DOI: 10.1586/14779072.2015.1039991] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Nowadays, there is a wide array of imaging studies available for the evaluation of coronary artery disease, each with its particular indications and strengths. Cardiac single photon emission tomography is mostly used to evaluate myocardial perfusion, having experienced recent marked improvements in image acquisition. Cardiac PET has its main utility in perfusion imaging, atherosclerosis and endothelial function evaluation, and viability assessment. Cardiovascular computed tomography has long been used as a reference test for non-invasive evaluation of coronary lesions and anatomic characterization. Cardiovascular magnetic resonance is currently the reference standard for non-invasive ventricular function evaluation and myocardial scarring delineation. These specific strengths have been enhanced with the advent of hybrid equipment, offering a true integration of different imaging modalities into a single, simultaneous and comprehensive study.
Collapse
Affiliation(s)
- Erick Alexanderson-Rosas
- Department of Nuclear Cardiology, Instituto Nacional de Cardiología 'Ignacio Chávez', Mexico City, Mexico
| | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Blankstein R. Can advances in nuclear cardiology hardware overcome the challenges of imaging obese patients? J Nucl Cardiol 2015; 22:276-8. [PMID: 25294434 DOI: 10.1007/s12350-014-0005-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2014] [Accepted: 09/17/2014] [Indexed: 10/24/2022]
Affiliation(s)
- Ron Blankstein
- Non-Invasive Cardiovascular Imaging Program, Departments of Medicine (Cardiovascular Division) and Radiology, Brigham and Women's Hospital, 75 Francis St, Boston, MA, 02115, USA,
| |
Collapse
|
38
|
Dorbala S, Blankstein R, Skali H, Park MA, Fantony J, Mauceri C, Semer J, Moore SC, Di Carli MF. Approaches to reducing radiation dose from radionuclide myocardial perfusion imaging. J Nucl Med 2015; 56:592-9. [PMID: 25766891 DOI: 10.2967/jnumed.112.115097] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2015] [Accepted: 02/27/2015] [Indexed: 11/16/2022] Open
Abstract
Radionuclide myocardial perfusion imaging (MPI) plays a vital role in the evaluation and management of patients with coronary artery disease. However, because of a steep growth in MPI in the mid 2000s, concerns about inappropriate use of MPI and imaging-related radiation exposure increased. In response, the professional societies developed appropriate-use criteria for MPI. Simultaneously, novel technology, image-reconstruction software for traditional scanners, and dedicated cardiac scanners emerged and facilitated the performance of MPI with low-dose and ultra-low-dose radiotracers. This paper provides a practical approach to performing low-radiation-dose MPI using traditional and novel technologies.
Collapse
Affiliation(s)
- Sharmila Dorbala
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Ron Blankstein
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Hicham Skali
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Mi-Ae Park
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Jolene Fantony
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Charles Mauceri
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - James Semer
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Stephen C Moore
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Marcelo F Di Carli
- Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, the Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| |
Collapse
|
39
|
Einstein AJ, Johnson LL, DeLuca AJ, Kontak AC, Groves DW, Stant J, Pozniakoff T, Cheng B, Rabbani LE, Bokhari S. Radiation dose and prognosis of ultra-low-dose stress-first myocardial perfusion SPECT in patients with chest pain using a high-efficiency camera. J Nucl Med 2015; 56:545-51. [PMID: 25745089 DOI: 10.2967/jnumed.114.150664] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2014] [Accepted: 01/30/2015] [Indexed: 01/29/2023] Open
Abstract
UNLABELLED Although SPECT myocardial perfusion imaging (MPI) provides valuable information about patients with chest pain, there is growing concern regarding its radiation burden and lengthy duration. New high-efficiency (HE) cameras and stress-first protocols both offer the potential to markedly reduce radiation. No previous study has assessed outcomes and radiation doses of patients undergoing MPI on an HE-SPECT camera using an ultra-low-dose stress-first protocol. METHODS One hundred patients presenting to the emergency department with chest pain who were candidates for stress-first MPI underwent injection of approximately 185 MBq (5 mCi) of (99m)Tc-tetrofosmin at peak stress, followed by supine and prone imaging on an HE-SPECT camera. Same-day rest imaging was performed on patients with any abnormality on imaging after stress. Radiation effective dose was calculated from administered and residual activities. Patients were contacted 3 mo after discharge, and electronic records were accessed to evaluate the need for reevaluation for chest pain, additional imaging, or cardiac events. RESULTS Stress-only imaging was performed in 69 patients, for whom radiation effective dose averaged 0.99 mSv and study duration, 117 min. Radiation dose averaged 2.22 mSv over all patients. At 3 mo, 96 patients were free of major adverse cardiac events, repeat hospital chest pain evaluation, and repeat imaging or stress testing. One year after MPI and hospital discharge, all patients were living and without acute coronary syndrome. CONCLUSION HE-SPECT stress-only imaging can be performed in more than two thirds of chest pain patients without a high pretest probability of a stress perfusion defect, with excellent prognosis, a radiation dose averaging 1 mSv, and a test duration of less than 2 h.
Collapse
Affiliation(s)
- Andrew J Einstein
- Cardiology Division, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York Department of Radiology, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York; and
| | - Lynne L Johnson
- Cardiology Division, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York
| | - Albert J DeLuca
- Cardiology Division, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York
| | - Andrew C Kontak
- Cardiology Division, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York
| | - Daniel W Groves
- Cardiology Division, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York
| | - Jennifer Stant
- Cardiology Division, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York
| | - Ted Pozniakoff
- Cardiology Division, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York
| | - Bin Cheng
- Department of Biostatistics, Columbia University, New York, New York
| | - LeRoy E Rabbani
- Cardiology Division, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York
| | - Sabahat Bokhari
- Cardiology Division, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, New York
| |
Collapse
|
40
|
Abstract
Positron-emitting myocardial flow radiotracers such as (15)O-water, (13)N-ammonia and (82)Rubidium in conjunction with positron-emission-tomography (PET) are increasingly applied in clinical routine for coronary artery disease (CAD) detection, yielding high diagnostic accuracy, while providing valuable information on cardiovascular (CV) outcome. Owing to a cyclotron dependency of (15)O-water and (13)N-ammonia, their clinical use for PET myocardial perfusion imaging is limited to a few centers. This limitation could be overcome by the increasing use of (82)Rubidium as it can be eluted from a commercially available (82)Strontium generator and, thus, is independent of a nearby cyclotron. Another novel F-18-labeled myocardial flow radiotracer is flurpiridaz which has attracted increasing interest due to its excellent radiotracer characteristics for perfusion and flow imaging with PET. In particular, the relatively long half-life of 109 minutes of flurpiridaz may afford a general application of this radiotracer for PET perfusion imaging comparable to technetium-99m-labeled single-photon emission computed tomography (SPECT). The ability of PET in conjunction with several radiotracers to assess myocardial blood flow (MBF) in ml/g/min at rest and during vasomotor stress has contributed to unravel pathophysiological mechanisms underlying coronary artery disease (CAD), to improve the detection and characterization of CAD burden in multivessel disease, and to provide incremental prognostic information in individuals with subclinical and clinically-manifest CAD. The concurrent evaluation of myocardial perfusion and MBF may lead to a new era of a personalized, image-guided therapy approach that may offer potential to further improve clinical outcome in CV disease patients but needing validation in large-scale clinical trials.
Collapse
Affiliation(s)
- Thomas H Schindler
- Division of Nuclear Medicine, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| |
Collapse
|
41
|
|
42
|
|
43
|
|
44
|
|