1
|
Zimmer RT, Auth A, Schierbauer J, Haupt S, Wachsmuth N, Zimmermann P, Voit T, Battelino T, Sourij H, Moser O. (Hybrid) Closed-Loop Systems: From Announced to Unannounced Exercise. Diabetes Technol Ther 2023. [PMID: 38133645 DOI: 10.1089/dia.2023.0293] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
Physical activity and exercise have many beneficial effects on general and type 1 diabetes (T1D) specific health and are recommended for individuals with T1D. Despite these health benefits, many people with T1D still avoid exercise since glycemic management during physical activity poses substantial glycemic and psychological challenges - which hold particularly true for unannounced exercise when using an AID system. Automated insulin delivery (AID) systems have demonstrated their efficacy in improving overall glycemia and in managing announced exercise in numerous studies. They are proven to increase time in range (70-180 mg/dL) and can especially counteract nocturnal hypoglycemia, even when evening exercise was performed. AID-systems consist of a pump administering insulin as well as a CGM sensor (plus transmitter), both communicating with a control algorithm integrated into a device (insulin pump, mobile phone/smart watch). Nevertheless, without manual pre-exercise adaptions, these systems still face a significant challenge around physical activity. Automatically adapting to the rapidly changing insulin requirements during unannounced exercise and physical activity is still the Achilles' heel of current AID systems. There is an urgent need for improving current AID-systems to safely and automatically maintain glucose management without causing derailments - so that going forward, exercise announcements will not be necessary in the future. Therefore, this narrative literature review aimed to discuss technological strategies to how current AID-systems can be improved in the future and become more proficient in overcoming the hurdle of unannounced exercise. For this purpose, the current state-of-the-art therapy recommendations for AID and exercise as well as novel research approaches are presented along with potential future solutions - in order to rectify their deficiencies in the endeavor to achieve fully automated AID-systems even around unannounced exercise.
Collapse
Affiliation(s)
- Rebecca Tanja Zimmer
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Alexander Auth
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Janis Schierbauer
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Sandra Haupt
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Nadine Wachsmuth
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Paul Zimmermann
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Thomas Voit
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Tadej Battelino
- University Children's Hospital, Ljubljana, Slovenia, Department of Endocrinology, Diabetes and Metabolism, Bohoriceva 20, Ljubljana, Slovenia, 1000
- Slovenia;
| | - Harald Sourij
- Medical University of Graz, 31475, Auenbruggerplatz 15, 8036 Graz, Graz, Austria, 8036;
| | - Othmar Moser
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Universitätsstraße 30, Bayreuth, Bayern, Germany, 95440;
| |
Collapse
|
2
|
Steyn LV, Drew D, Vlachos D, Huey B, Cocchi K, Price ND, Johnson R, Putnam CW, Papas KK. Accelerated absorption of regular insulin administered via a vascularizing permeable microchamber implanted subcutaneously in diabetic Rattus norvegicus. PLoS One 2023; 18:e0278794. [PMID: 37384782 PMCID: PMC10310011 DOI: 10.1371/journal.pone.0278794] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 06/13/2023] [Indexed: 07/01/2023] Open
Abstract
In Type 1 diabetes patients, even ultra-rapid acting insulins injected subcutaneously reach peak concentrations in 45 minutes or longer. The lag time between dosing and peak concentration, as well as intra- and inter-subject variability, render prandial glucose control and dose consistency difficult. We postulated that insulin absorption from subcutaneously implantable vascularizing microchambers would be significantly faster than conventional subcutaneous injection. Male athymic nude R. norvegicus rendered diabetic with streptozotocin were implanted with vascularizing microchambers (single chamber; 1.5 cm2 surface area per side; nominal volume, 22.5 μl). Plasma insulin was assayed after a single dose (1.5 U/kg) of diluted insulin human (Humulin®R U-100), injected subcutaneously or via microchamber. Microchambers were also implanted in additional animals and retrieved at intervals for histologic assessment of vascularity. Following conventional subcutaneous injection, the mean peak insulin concentration was 22.7 (SD 14.2) minutes. By contrast, when identical doses of insulin were injected via subcutaneous microchamber 28 days after implantation, the mean peak insulin time was shortened to 7.50 (SD 4.52) minutes. Peak insulin concentrations were similar by either route; however, inter-subject variability was reduced when insulin was administered via microchamber. Histologic examination of tissue surrounding microchambers showed mature vascularization on days 21 and 40 post-implantation. Implantable vascularizing microchambers of similar design may prove clinically useful for insulin dosing, either intermittently by needle, or continuously by pump including in "closed loop" systems, such as the artificial pancreas.
Collapse
Affiliation(s)
- Leah V. Steyn
- Institute for Cellular Transplantation, Department of Surgery, University of Arizona College of Medicine-Tucson, University of Arizona, Tucson, AZ, United States of America
| | - Delaney Drew
- Institute for Cellular Transplantation, Department of Surgery, University of Arizona College of Medicine-Tucson, University of Arizona, Tucson, AZ, United States of America
| | - Demetri Vlachos
- Institute for Cellular Transplantation, Department of Surgery, University of Arizona College of Medicine-Tucson, University of Arizona, Tucson, AZ, United States of America
| | - Barry Huey
- Institute for Cellular Transplantation, Department of Surgery, University of Arizona College of Medicine-Tucson, University of Arizona, Tucson, AZ, United States of America
| | - Katie Cocchi
- Institute for Cellular Transplantation, Department of Surgery, University of Arizona College of Medicine-Tucson, University of Arizona, Tucson, AZ, United States of America
| | - Nicholas D. Price
- Institute for Cellular Transplantation, Department of Surgery, University of Arizona College of Medicine-Tucson, University of Arizona, Tucson, AZ, United States of America
| | - Robert Johnson
- Procyon Technologies, LLC., Medical Research Building (Room 121), University of Arizona, Tucson, AZ, United States of America
| | - Charles W. Putnam
- Institute for Cellular Transplantation, Department of Surgery, University of Arizona College of Medicine-Tucson, University of Arizona, Tucson, AZ, United States of America
| | - Klearchos K. Papas
- Institute for Cellular Transplantation, Department of Surgery, University of Arizona College of Medicine-Tucson, University of Arizona, Tucson, AZ, United States of America
- Procyon Technologies, LLC., Medical Research Building (Room 121), University of Arizona, Tucson, AZ, United States of America
| |
Collapse
|
3
|
Goo YT, Lee S, Choi JY, Kim MS, Sin GH, Hong SH, Kim CH, Song SH, Choi YW. Enhanced oral absorption of insulin: hydrophobic ion pairing and a self-microemulsifying drug delivery system using a D-optimal mixture design. Drug Deliv 2022; 29:2831-2845. [PMID: 36050870 PMCID: PMC9448375 DOI: 10.1080/10717544.2022.2118399] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
The lipophilicity of a peptide drug can be considerably increased by hydrophobic ion pairing with amphiphilic counterions for successful incorporation into lipid-based formulations. Herein, to enhance the oral absorption of insulin (INS), a self-microemulsifying drug delivery system (SMEDDS) formulation was developed. Prior to optimization, INS was complexed with sodium n-octadecyl sulfate (SOS) to increase the loading into the SMEDDS. The INS–SOS complex was characterized via scanning electron microscopy, Fourier transform infrared spectroscopy, differential scanning calorimetry, and its dissociation behavior. The SMEDDS was optimized using a D-optimal mixture design with three independent variables including Capmul MCM (X1, 9.31%), Labrasol (X2, 49.77%), and Tetraglycol (X3, 40.92%) and three response variables including droplet size (Y1, 115.2 nm), INS stability (Y2, 46.75%), and INS leakage (Y3, 17.67%). The desirability function was 0.766, indicating excellent agreement between the predicted and experimental values. The stability of INS-SOS against gastrointestinal enzymes was noticeably improved in the SMEDDS, and the majority of INS remained in oil droplets during release. Following oral administration in diabetic rats, the optimized SMEDDS resulted in pharmacological availabilities of 3.23% (50 IU/kg) and 2.13% (100 IU/kg). Thus, the optimized SMEDDS is a good candidate for the practical development of oral delivery of peptide drugs such as INS.
Collapse
Affiliation(s)
- Yoon Tae Goo
- College of Pharmacy, Chung-Ang University, Seoul, Republic of Korea
| | - Sangkil Lee
- College of Pharmacy, Keimyung University, Daegu, Republic of Korea
| | - Ji Yeh Choi
- Department of Psychology, York University, Toronto, Ontario, Canada
| | - Min Song Kim
- College of Pharmacy, Chung-Ang University, Seoul, Republic of Korea
| | - Gi Hyeong Sin
- College of Pharmacy, Chung-Ang University, Seoul, Republic of Korea
| | - Sun Ho Hong
- College of Pharmacy, Chung-Ang University, Seoul, Republic of Korea
| | - Chang Hyun Kim
- College of Pharmacy, Chung-Ang University, Seoul, Republic of Korea
| | - Seh Hyon Song
- College of Pharmacy, Kyungsung University, Busan, Republic of Korea
| | - Young Wook Choi
- College of Pharmacy, Chung-Ang University, Seoul, Republic of Korea
| |
Collapse
|
4
|
Veletić M, Apu EH, Simić M, Bergsland J, Balasingham I, Contag CH, Ashammakhi N. Implants with Sensing Capabilities. Chem Rev 2022; 122:16329-16363. [PMID: 35981266 DOI: 10.1021/acs.chemrev.2c00005] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Because of the aging human population and increased numbers of surgical procedures being performed, there is a growing number of biomedical devices being implanted each year. Although the benefits of implants are significant, there are risks to having foreign materials in the body that may lead to complications that may remain undetectable until a time at which the damage done becomes irreversible. To address this challenge, advances in implantable sensors may enable early detection of even minor changes in the implants or the surrounding tissues and provide early cues for intervention. Therefore, integrating sensors with implants will enable real-time monitoring and lead to improvements in implant function. Sensor integration has been mostly applied to cardiovascular, neural, and orthopedic implants, and advances in combined implant-sensor devices have been significant, yet there are needs still to be addressed. Sensor-integrating implants are still in their infancy; however, some have already made it to the clinic. With an interdisciplinary approach, these sensor-integrating devices will become more efficient, providing clear paths to clinical translation in the future.
Collapse
Affiliation(s)
- Mladen Veletić
- Department of Electronic Systems, Norwegian University of Science and Technology, 7491 Trondheim, Norway.,The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Ehsanul Hoque Apu
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States.,Division of Hematology and Oncology, Department of Internal Medicine, Michigan Medicine, University of Michigan, Ann Arbor, Michigan 48105, United States
| | - Mitar Simić
- Faculty of Electrical Engineering, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
| | - Jacob Bergsland
- The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Ilangko Balasingham
- Department of Electronic Systems, Norwegian University of Science and Technology, 7491 Trondheim, Norway.,The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Christopher H Contag
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States
| | - Nureddin Ashammakhi
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States.,Department of Bioengineering, University of California, Los Angeles, California 90095, United States
| |
Collapse
|
5
|
Paldus B, Morrison D, Lee M, Zaharieva DP, Riddell MC, O'Neal DN. Strengths and Challenges of Closed-Loop Insulin Delivery During Exercise in People With Type 1 Diabetes: Potential Future Directions. J Diabetes Sci Technol 2022:19322968221088327. [PMID: 35466723 DOI: 10.1177/19322968221088327] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Exercise has many physical and psychological benefits and is recommended for people with type 1 diabetes; however, there are many barriers to exercise, including glycemic instability and fear of hypoglycemia. Closed-loop (CL) systems have shown benefit in the overall glycemic management of type 1 diabetes, including improving HbA1c levels and reducing the incidence of nocturnal hypoglycemia; however, these systems are challenged by the rapidly changing insulin needs with exercise. This commentary focuses on the principles, strengths, and challenges of CL in the management of exercise, and discusses potential approaches, including the use of additional physiological signals, to address their shortcomings in the pursuit of fully automated CL systems.
Collapse
Affiliation(s)
- Barbora Paldus
- Department of Medicine, The University of Melbourne, Victoria, Australia
- Department of Endocrinology & Diabetes, St. Vincent's Hospital Melbourne, Victoria, Australia
| | - Dale Morrison
- Department of Medicine, The University of Melbourne, Victoria, Australia
| | - Melissa Lee
- Department of Medicine, The University of Melbourne, Victoria, Australia
- Department of Endocrinology & Diabetes, St. Vincent's Hospital Melbourne, Victoria, Australia
| | - Dessi P Zaharieva
- Division of Endocrinology, Department of Pediatrics, School of Medicine, Stanford University, CA, USA
| | - Michael C Riddell
- School of Kinesiology and Health Science, Muscle Health Research Centre, York University, Toronto, ON, Canada
| | - David N O'Neal
- Department of Medicine, The University of Melbourne, Victoria, Australia
- Department of Endocrinology & Diabetes, St. Vincent's Hospital Melbourne, Victoria, Australia
| |
Collapse
|
6
|
Zhang J, Xu J, Lim J, Nolan JK, Lee H, Lee CH. Wearable Glucose Monitoring and Implantable Drug Delivery Systems for Diabetes Management. Adv Healthc Mater 2021; 10:e2100194. [PMID: 33930258 DOI: 10.1002/adhm.202100194] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 03/12/2021] [Indexed: 12/11/2022]
Abstract
The global cost of diabetes care exceeds $1 trillion each year with more than $327 billion being spent in the United States alone. Despite some of the advances in diabetes care including continuous glucose monitoring systems and insulin pumps, the technology associated with managing diabetes has largely remained unchanged over the past several decades. With the rise of wearable electronics and novel functional materials, the field is well-poised for the next generation of closed-loop diabetes care. Wearable glucose sensors implanted within diverse platforms including skin or on-tooth tattoos, skin-mounted patches, eyeglasses, contact lenses, fabrics, mouthguards, and pacifiers have enabled noninvasive, unobtrusive, and real-time analysis of glucose excursions in ambulatory care settings. These wearable glucose sensors can be integrated with implantable drug delivery systems, including an insulin pump, glucose responsive insulin release implant, and islets transplantation, to form self-regulating closed-loop systems. This review article encompasses the emerging trends and latest innovations of wearable glucose monitoring and implantable insulin delivery technologies for diabetes management with a focus on their advanced materials and construction. Perspectives on the current unmet challenges of these strategies are also discussed to motivate future technological development toward improved patient care in diabetes management.
Collapse
Affiliation(s)
- Jinyuan Zhang
- Weldon School of Biomedical Engineering Purdue University West Lafayette IN 47907 USA
| | - Jian Xu
- Weldon School of Biomedical Engineering Purdue University West Lafayette IN 47907 USA
| | - Jongcheon Lim
- Weldon School of Biomedical Engineering Purdue University West Lafayette IN 47907 USA
| | - James K. Nolan
- Weldon School of Biomedical Engineering Purdue University West Lafayette IN 47907 USA
| | - Hyowon Lee
- Weldon School of Biomedical Engineering Purdue University West Lafayette IN 47907 USA
| | - Chi Hwan Lee
- Weldon School of Biomedical Engineering Purdue University West Lafayette IN 47907 USA
- School of Mechanical Engineering School of Materials Engineering Purdue University West Lafayette IN 47907 USA
| |
Collapse
|
7
|
Iacovacci V, Tamadon I, Kauffmann EF, Pane S, Simoni V, Marziale L, Aragona M, Cobuccio L, Chiarugi M, Dario P, Del Prato S, Ricotti L, Vistoli F, Menciassi A. A fully implantable device for intraperitoneal drug delivery refilled by ingestible capsules. Sci Robot 2021; 6:6/57/eabh3328. [PMID: 34408097 DOI: 10.1126/scirobotics.abh3328] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 07/28/2021] [Indexed: 12/18/2022]
Abstract
Creating fully implantable robots that replace or restore physiological processes is a great challenge in medical robotics. Restoring blood glucose homeostasis in patients with type 1 diabetes is particularly interesting in this sense. Intraperitoneal insulin delivery could revolutionize type 1 diabetes treatment. At present, the intraperitoneal route is little used because it relies on accessing ports connecting intraperitoneal catheters to external reservoirs. Drug-loaded pills transported across the digestive system to refill an implantable reservoir in a minimally invasive fashion could open new possibilities in intraperitoneal delivery. Here, we describe PILLSID (PILl-refiLled implanted System for Intraperitoneal Delivery), a fully implantable robotic device refillable through ingestible magnetic pills carrying drugs. Once refilled, the device acts as a programmable microinfusion system for precise intraperitoneal delivery. The robotic device is grounded on a combination of magnetic switchable components, miniaturized mechatronic elements, a wireless powering system, and a control unit to implement the refilling and control the infusion processes. In this study, we describe the PILLSID prototyping. The device key blocks are validated as single components and within the integrated device at the preclinical level. We demonstrate that the refilling mechanism works efficiently in vivo and that the blood glucose level can be safely regulated in diabetic swine. The device weights 165 grams and is 78 millimeters by 63 millimeters by 35 millimeters, comparable with commercial implantable devices yet overcoming the urgent critical issues related to reservoir refilling and powering.
Collapse
Affiliation(s)
- Veronica Iacovacci
- BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy.,Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy.,Department of Mechanical and Automation Engineering, Chinese University of Hong Kong, Shatin NT, Hong Kong SAR
| | - Izadyar Tamadon
- BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy.,Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy
| | - Emanuele Federico Kauffmann
- Division of General and Transplant Surgery, Azienda Ospedaliera Universitaria Pisana, University of Pisa, Via Paradisa 2, 56124 Pisa, Italy
| | - Stefano Pane
- BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy.,Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy
| | - Virginia Simoni
- BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy.,Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy
| | - Leonardo Marziale
- BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy.,Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy
| | - Michele Aragona
- Department of Clinical and Experimental Medicine, Section of Metabolic Diseases and Diabetes, University of Pisa, Via Savi 10, 56126 Pisa, Italy
| | - Luigi Cobuccio
- Emergency Surgery Unit, Azienda Ospedaliero Universitaria Pisana Cisanello Hospital, Via Piero Trivella, 56124 Pisa, Italy
| | - Massimo Chiarugi
- Emergency Surgery Unit, Azienda Ospedaliero Universitaria Pisana Cisanello Hospital, Via Piero Trivella, 56124 Pisa, Italy
| | - Paolo Dario
- BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy.,Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy.,Dubai Future Labs, Dubai, United Arab Emirates.,Beijing Advanced Innovation Center for Intelligent Robots and Systems, Beijing Institute of Technology, Beijing, China.,Department of Mechanical Engineering, Tianjin University, Tianjin, China
| | - Stefano Del Prato
- Department of Clinical and Experimental Medicine, Section of Metabolic Diseases and Diabetes, University of Pisa, Via Savi 10, 56126 Pisa, Italy
| | - Leonardo Ricotti
- BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy.,Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy
| | - Fabio Vistoli
- Division of General and Transplant Surgery, Azienda Ospedaliera Universitaria Pisana, University of Pisa, Via Paradisa 2, 56124 Pisa, Italy
| | - Arianna Menciassi
- BioRobotics Institute, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy. .,Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy
| |
Collapse
|
8
|
Szunerits S, Melinte S, Barras A, Pagneux Q, Voronova A, Abderrahmani A, Boukherroub R. The impact of chemical engineering and technological advances on managing diabetes: present and future concepts. Chem Soc Rev 2021; 50:2102-2146. [PMID: 33325917 DOI: 10.1039/c9cs00886a] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Monitoring blood glucose levels for diabetic patients is critical to achieve tight glycaemic control. As none of the current antidiabetic treatments restore lost functional β-cell mass in diabetic patients, insulin injections and the use of insulin pumps are most widely used in the management of glycaemia. The use of advanced and intelligent chemical engineering, together with the incorporation of micro- and nanotechnological-based processes have lately revolutionized diabetic management. The start of this concept goes back to 1974 with the description of an electrode that repeatedly measures the level of blood glucose and triggers insulin release from an infusion pump to enter the blood stream from a small reservoir upon need. Next to the insulin pumps, other drug delivery routes, including nasal, transdermal and buccal, are currently investigated. These processes necessitate competences from chemists, engineers-alike and innovative views of pharmacologists and diabetologists. Engineered micro and nanostructures hold a unique potential when it comes to drug delivery applications required for the treatment of diabetic patients. As the technical aspects of chemistry, biology and informatics on medicine are expanding fast, time has come to step back and to evaluate the impact of technology-driven chemistry on diabetics and how the bridges from research laboratories to market products are established. In this review, the large variety of therapeutic approaches proposed in the last five years for diabetic patients are discussed in an applied context. A survey of the state of the art of closed-loop insulin delivery strategies in response to blood glucose level fluctuation is provided together with insights into the emerging key technologies for diagnosis and drug development. Chemical engineering strategies centered on preserving and regenerating functional pancreatic β-cell mass are evoked in addition as they represent a permanent solution for diabetic patients.
Collapse
Affiliation(s)
- Sabine Szunerits
- Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France.
| | - Sorin Melinte
- Institute of Information and Communication Technologies, Electronics and Applied Mathematics, Université catholique de Louvain, 1348 Louvain-la-Neuve, Belgium
| | - Alexandre Barras
- Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France.
| | - Quentin Pagneux
- Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France.
| | - Anna Voronova
- Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France.
| | - Amar Abderrahmani
- Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France.
| | - Rabah Boukherroub
- Univ. Lille, CNRS, Centrale Lille, Univ. Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France.
| |
Collapse
|
9
|
Kraft G, Coate KC, Smith M, Farmer B, Scott M, Cherrington AD, Edgerton DS. The Importance of the Mechanisms by Which Insulin Regulates Meal-Associated Liver Glucose Uptake in the Dog. Diabetes 2021; 70:1292-1302. [PMID: 33757993 PMCID: PMC8275892 DOI: 10.2337/db20-1271] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 03/18/2021] [Indexed: 12/17/2022]
Abstract
Hepatic glucose uptake (HGU) is critical for maintaining normal postprandial glucose metabolism. Insulin is clearly a key regulator of HGU, but the physiologic mechanisms by which it acts have yet to be established. This study sought to determine the mechanisms by which insulin regulates liver glucose uptake under postprandial-like conditions (hyperinsulinemia, hyperglycemia, and a positive portal vein-to-arterial glucose gradient). Portal vein insulin infusion increased hepatic insulin levels fivefold in healthy dogs. In one group (n = 7), the physiologic response was allowed to fully occur, while in another (n = 7), insulin's indirect hepatic effects, occurring secondary to its actions on adipose tissue, pancreas, and brain, were blocked. This was accomplished by infusing triglyceride (intravenous), glucagon (portal vein), and inhibitors of brain insulin action (intracerebroventricular) to prevent decreases in plasma free fatty acids or glucagon, while blocking increased hypothalamic insulin signaling for 4 h. In contrast to the indirect hepatic effects of insulin, which were previously shown capable of independently generating a half-maximal stimulation of HGU, direct hepatic insulin action was by itself able to fully stimulate HGU. This suggests that under hyperinsulinemic/hyperglycemic conditions insulin's indirect effects are redundant to direct engagement of hepatocyte insulin receptors.
Collapse
Affiliation(s)
- Guillaume Kraft
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| | - Katie C Coate
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| | - Marta Smith
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| | - Ben Farmer
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| | - Melanie Scott
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| | - Alan D Cherrington
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| | - Dale S Edgerton
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Nashville, TN
| |
Collapse
|
10
|
Jarosinski MA, Dhayalan B, Rege N, Chatterjee D, Weiss MA. 'Smart' insulin-delivery technologies and intrinsic glucose-responsive insulin analogues. Diabetologia 2021; 64:1016-1029. [PMID: 33710398 PMCID: PMC8158166 DOI: 10.1007/s00125-021-05422-6] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 01/15/2021] [Indexed: 02/08/2023]
Abstract
Insulin replacement therapy for diabetes mellitus seeks to minimise excursions in blood glucose concentration above or below the therapeutic range (hyper- or hypoglycaemia). To mitigate acute and chronic risks of such excursions, glucose-responsive insulin-delivery technologies have long been sought for clinical application in type 1 and long-standing type 2 diabetes mellitus. Such 'smart' systems or insulin analogues seek to provide hormonal activity proportional to blood glucose levels without external monitoring. This review highlights three broad strategies to co-optimise mean glycaemic control and time in range: (1) coupling of continuous glucose monitoring (CGM) to delivery devices (algorithm-based 'closed-loop' systems); (2) glucose-responsive polymer encapsulation of insulin; and (3) mechanism-based hormone modifications. Innovations span control algorithms for CGM-based insulin-delivery systems, glucose-responsive polymer matrices, bio-inspired design based on insulin's conformational switch mechanism upon insulin receptor engagement, and glucose-responsive modifications of new insulin analogues. In each case, innovations in insulin chemistry and formulation may enhance clinical outcomes. Prospects are discussed for intrinsic glucose-responsive insulin analogues containing a reversible switch (regulating bioavailability or conformation) that can be activated by glucose at high concentrations.
Collapse
Affiliation(s)
- Mark A Jarosinski
- Department of Biochemistry and Molecular Biology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Balamurugan Dhayalan
- Department of Biochemistry and Molecular Biology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Nischay Rege
- Department of Medicine, Yale University School of Medicine, New Haven, CT, USA
| | - Deepak Chatterjee
- Department of Biochemistry and Molecular Biology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Michael A Weiss
- Department of Biochemistry and Molecular Biology, Indiana University School of Medicine, Indianapolis, IN, USA.
- Department of Chemistry, Indiana University, Bloomington, IN, USA.
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA.
| |
Collapse
|
11
|
Vora LK, Moffatt K, Tekko IA, Paredes AJ, Volpe-Zanutto F, Mishra D, Peng K, Raj Singh Thakur R, Donnelly RF. Microneedle array systems for long-acting drug delivery. Eur J Pharm Biopharm 2021; 159:44-76. [DOI: 10.1016/j.ejpb.2020.12.006] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 11/25/2020] [Accepted: 12/08/2020] [Indexed: 12/31/2022]
|
12
|
Wang Z, Wang J, Kahkoska AR, Buse JB, Gu Z. Developing Insulin Delivery Devices with Glucose Responsiveness. Trends Pharmacol Sci 2021; 42:31-44. [PMID: 33250274 PMCID: PMC7758938 DOI: 10.1016/j.tips.2020.11.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 11/03/2020] [Accepted: 11/03/2020] [Indexed: 12/18/2022]
Abstract
Individuals with type 1 and advanced type 2 diabetes require daily insulin therapy to maintain blood glucose levels in normoglycemic ranges to prevent associated morbidity and mortality. Optimal insulin delivery should offer both precise dosing in response to real-time blood glucose levels as well as a feasible and low-burden administration route to promote long-term adherence. A series of glucose-responsive insulin delivery mechanisms and devices have been reported to increase patient compliance while mitigating the risk of hypoglycemia. This review discusses currently available insulin delivery devices, overviews recent developments towards the generation of glucose-responsive delivery systems, and provides commentary on the opportunities and barriers ahead regarding the integration and translation of current glucose-responsive insulin delivery designs.
Collapse
Affiliation(s)
- Zejun Wang
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA; Jonsson Comprehensive Cancer Center, University of California, Los Angeles, CA 90095, USA
| | - Jinqiang Wang
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA; Jonsson Comprehensive Cancer Center, University of California, Los Angeles, CA 90095, USA; College of Pharmaceutical Sciences, Zhejiang University, 310058 Hangzhou, China
| | - Anna R Kahkoska
- Department of Medicine, University of North Carolina School of Medicine, Chapel Hill, NC 27599, USA
| | - John B Buse
- Department of Medicine, University of North Carolina School of Medicine, Chapel Hill, NC 27599, USA.
| | - Zhen Gu
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA; Jonsson Comprehensive Cancer Center, University of California, Los Angeles, CA 90095, USA; College of Pharmaceutical Sciences, Zhejiang University, 310058 Hangzhou, China; California NanoSystems Institute, University of California, Los Angeles, CA 90095, USA.
| |
Collapse
|
13
|
Meunier L, Aguadé AS, Videau Y, Verboux D, Fagot-Campagna A, Gastaldi-Menager C, Amadou C. Age, Male Gender, and Social Deprivation Are Associated with a Lower Rate of Insulin Pump Therapy Initiation in Adults with Type 1 Diabetes: A Population-Based Study. Diabetes Technol Ther 2021; 23:8-19. [PMID: 32522046 DOI: 10.1089/dia.2020.0112] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Objectives: The objective of this population-based study was to identify factors associated with insulin pump therapy initiation in adults with insulin-requiring diabetes in France in 2015. Method: People with insulin-requiring diabetes and their characteristics were identified from the national health data system. Factors associated with insulin pump therapy initiation were identified by logistic regression analysis. Results: The study focused on 614,913 adults with diabetes treated by multiple daily injections before 2015: 4083 of them initiated insulin pump therapy during the year (71% of them had type 1 diabetes, T1D). Factors associated with insulin pump therapy initiation were the number of consultations with an endocrinologist within the past 2 years (2 vs. 0, odds ratio [OR] = 1.5, P < 0.01), the presence of a chronic cardiovascular or neurovascular disease (OR = 1.6 for T1D, OR = 1.3 for type 2 diabetes [T2D], P < 0.01) and treatment with antidepressants/anxiolytics (OR = 1.2 for T1D, OR = 1.4 for T2D, P < 0.01). The other determinants were female gender (OR = 1.5, P < 0.01) and history of hospitalization for acute metabolic complications (OR = 1.14, P < 0.01) in T1D. Factors associated with less insulin pump therapy initiation were age, duration of diabetes, end-stage renal disease, and social deprivation (OR = 0.662, P < 0.01, T1D only). Conclusion: Predictive factors of insulin pump therapy initiation in people with insulin-requiring diabetes in 2015 in France were globally consistent with clinical practice guidelines. Age, male gender, and social deprivation are still associated with a lower rate of insulin pump therapy initiation in adults with T1D.
Collapse
Affiliation(s)
- Lise Meunier
- CNAM (Caisse Nationale d'Assurance Maladie), French National Health Insurance, Paris, France
| | - Anne-Sophie Aguadé
- CNAM (Caisse Nationale d'Assurance Maladie), French National Health Insurance, Paris, France
| | - Yann Videau
- ERUDITE (Research Team on the Use of Individual Data related to Economic Theory). University of Paris-Est Créteil, Créteil, France
| | - Dorian Verboux
- CNAM (Caisse Nationale d'Assurance Maladie), French National Health Insurance, Paris, France
| | - Anne Fagot-Campagna
- CNAM (Caisse Nationale d'Assurance Maladie), French National Health Insurance, Paris, France
| | | | - Coralie Amadou
- Department of Diabetes and Endocrinology, University of Paris-Saclay and Sud-Francilien Hospital, Corbeil-Essonnes, France
| |
Collapse
|
14
|
Abstract
BACKGROUND Advances in pump technology have increased the popularity of this treatment modality among patients with type 1 diabetes and recently also among patients with type 2 diabetes. AREAS OF UNCERTAINTY Four decades after the incorporation of the insulin pump in clinical use, questions regarding its efficacy, occurrence rate of short-term complications as hypoglycemia and diabetes ketoacidosis, timing of pump initiation, and selected populations for use remain unanswered. DATA SOURCES A review of the literature was performed using the PubMed database to identify all articles published up till December 2018, with the search terms including insulin pump therapy/continuous subcutaneous insulin delivery. The Cochrane database was searched for meta-analysis evaluating controlled randomized trials. Consensuses guidelines published by the International Society for Pediatric and Adolescent Diabetes, American Diabetes Association, and Advanced Technologies and Treatments for Diabetes year books were additionally reviewed for relevant cited articles. THERAPEUTIC ADVANCES Insulin pump therapy offers flexible management of diabetes. It enables adjustment of basal insulin to daily requirements and circadian needs, offers more precise treatment for meals and physical activity, and, when integrated with continuous glucose monitoring, allows glucose responsive insulin delivery. The ability to download and transmit data for analysis allow for treatment optimization. Newer pumps are simple to operate and increase user experience. Studies support the efficacy of pump therapy in improving glycemic control and reducing the occurrence of hypoglycemia without increasing episodes of diabetes ketoacidosis. They also improve quality of life. Recent evidence suggests a role for pump therapy in reducing microvascular and macrovascular diabetes-related complications. CONCLUSIONS Insulin pump therapy appears to be effective and safe in people with T1D regardless of age. Future advancements will include incorporation of closed loop and various decision support systems to aid and improve metabolic control and quality of life.
Collapse
|
15
|
Magisson J, Sassi A, Kobalyan A, Burcez CT, Bouaoun R, Vix M, Jeandidier N, Sigrist S. A fully implantable device for diffuse insulin delivery at extraperitoneal site for physiological treatment of type 1 diabetes. J Control Release 2020; 320:431-441. [DOI: 10.1016/j.jconrel.2020.01.055] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 01/23/2020] [Accepted: 01/29/2020] [Indexed: 12/22/2022]
|
16
|
Khursheed R, Singh SK, Wadhwa S, Kapoor B, Gulati M, Kumar R, Ramanunny AK, Awasthi A, Dua K. Treatment strategies against diabetes: Success so far and challenges ahead. Eur J Pharmacol 2019; 862:172625. [DOI: 10.1016/j.ejphar.2019.172625] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Revised: 08/11/2019] [Accepted: 08/20/2019] [Indexed: 12/18/2022]
|
17
|
VandenBerg MA, Webber MJ. Biologically Inspired and Chemically Derived Methods for Glucose-Responsive Insulin Therapy. Adv Healthc Mater 2019; 8:e1801466. [PMID: 30605265 DOI: 10.1002/adhm.201801466] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Revised: 12/11/2018] [Indexed: 12/13/2022]
Abstract
The controlled delivery of therapeutics in a manner responsive to physiological indicators has promise in realizing new therapeutic approaches to combat disease. This approach is especially relevant in the context of diabetes. Natural fluctuations in blood glucose seen in the healthy state, complete with peaks and troughs, are poorly regulated as a result of detrimental production or ineffective signaling of the insulin hormone. While several manifestations of diabetes are treated with regularly administered exogenous insulin, the present standard of care results in suboptimal glycemic management that poorly recreates natural hormone control, leading to long-term instability and a significantly increased risk for secondary health complications. New synthetic technologies that make insulin available only when needed, and at the exact dose required, have been explored under the broad vision of realizing a "fully synthetic pancreas." Yet, many challenges remain to realizing a technology that is appropriately responsive, safe, and well integrated into a manageable routine. Herein, many of the approaches explored thus far to sense physiological blood glucose and elicit response through the release of therapeutic insulin are summarized. The approaches point to a new, autonomous approach to managing diabetes with biomimetic therapy.
Collapse
Affiliation(s)
- Michael A. VandenBerg
- Department of Chemical & Biomolecular EngineeringUniversity of Notre Dame 205 McCourtney Hall Notre Dame IN 46556 USA
| | - Matthew J. Webber
- Department of Chemical & Biomolecular EngineeringUniversity of Notre Dame 205 McCourtney Hall Notre Dame IN 46556 USA
| |
Collapse
|
18
|
Edgerton DS, Scott M, Farmer B, Williams PE, Madsen P, Kjeldsen T, Brand CL, Fledelius C, Nishimura E, Cherrington AD. Targeting insulin to the liver corrects defects in glucose metabolism caused by peripheral insulin delivery. JCI Insight 2019; 5:126974. [PMID: 30830873 DOI: 10.1172/jci.insight.126974] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Peripheral hyperinsulinemia resulting from subcutaneous insulin injection is associated with metabolic defects which include abnormal glucose metabolism. The first aim of this study was to quantify the impairments in liver and muscle glucose metabolism that occur when insulin is delivered via a peripheral vein compared to when it is given through its endogenous secretory route (the hepatic portal vein) in overnight fasted conscious dogs. The second aim was to determine if peripheral delivery of a hepato-preferential insulin analog could restore the physiologic response to insulin that occurs under meal feeding conditions. This study is the first to show that hepatic glucose uptake correlates with insulin's direct effects on the liver under hyperinsulinemic-hyperglycemic conditions. In addition, glucose uptake was equally divided between the liver and muscle when insulin was infused into the portal vein, but when it was delivered into a peripheral vein the percentage of glucose taken up by muscle was 4-times greater than that going to the liver, with liver glucose uptake being less than half of normal. These defects could not be corrected by adjusting the dose of peripheral insulin. On the other hand, hepatic and non-hepatic glucose metabolism could be fully normalized by a hepato-preferential insulin analog.
Collapse
Affiliation(s)
- Dale S Edgerton
- Vanderbilt University School of Medicine, Department of Molecular Physiology and Biophysics, Nashville, Tennessee, USA
| | - Melanie Scott
- Vanderbilt University School of Medicine, Department of Molecular Physiology and Biophysics, Nashville, Tennessee, USA
| | - Ben Farmer
- Vanderbilt University School of Medicine, Department of Molecular Physiology and Biophysics, Nashville, Tennessee, USA
| | - Phillip E Williams
- Vanderbilt University Medical Center, Division of Surgical Research, Nashville, Tennessee, USA
| | - Peter Madsen
- Research and Development, Novo Nordisk A/S, Novo Nordisk Park, Maaleov, Denmark
| | - Thomas Kjeldsen
- Research and Development, Novo Nordisk A/S, Novo Nordisk Park, Maaleov, Denmark
| | - Christian L Brand
- Research and Development, Novo Nordisk A/S, Novo Nordisk Park, Maaleov, Denmark
| | - Christian Fledelius
- Research and Development, Novo Nordisk A/S, Novo Nordisk Park, Maaleov, Denmark
| | - Erica Nishimura
- Research and Development, Novo Nordisk A/S, Novo Nordisk Park, Maaleov, Denmark
| | - Alan D Cherrington
- Vanderbilt University School of Medicine, Department of Molecular Physiology and Biophysics, Nashville, Tennessee, USA
| |
Collapse
|
19
|
Hu C, Jia W. Therapeutic medications against diabetes: What we have and what we expect. Adv Drug Deliv Rev 2019; 139:3-15. [PMID: 30529309 DOI: 10.1016/j.addr.2018.11.008] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 09/01/2018] [Accepted: 11/27/2018] [Indexed: 02/06/2023]
Abstract
Diabetes has become one of the largest global health and economic burdens, with its increased prevalence and high complication ratio. Stable and satisfactory blood glucose control are vital to reduce diabetes-related complications. Therefore, continuous attempts have been made in antidiabetic drugs, treatment routes, and traditional Chinese medicine to achieve better disease control. New antidiabetic drugs and appropriate combinations of these drugs have increased diabetes control significantly. Besides, novel treatment routes including oral antidiabetic peptide delivery, nanocarrier delivery system, implantable drug delivery system are also pivotal for diabetes control, with its greater efficiency, increased bioavailability, decreased toxicity and reduced dosing frequency. Among these new routes, nanotechnology, artificial pancreas and islet cell implantation have shown great potential in diabetes therapy. Traditional Chinese medicine also offer new options for diabetes treatment. Our paper aim to overview these therapeutic methods for diabetes therapy. Proper combinations of these existing anti-diabetic medications and searching for novel routes are both necessary for better diabetes control.
Collapse
Affiliation(s)
- Cheng Hu
- Shanghai Diabetes Institute, Shanghai Key Laboratory of Diabetes Mellitus, Shanghai Key Clinical Center for Metabolic Diseases, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, People's Republic of China; Shanghai Jiao Tong University Affiliated Sixth People's Hospital South Campus, 6600 Nanfeng Road, Shanghai 200433, People's Republic of China
| | - Weiping Jia
- Shanghai Diabetes Institute, Shanghai Key Laboratory of Diabetes Mellitus, Shanghai Key Clinical Center for Metabolic Diseases, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, People's Republic of China.
| |
Collapse
|
20
|
Tauschmann M, Hovorka R. Technology in the management of type 1 diabetes mellitus - current status and future prospects. Nat Rev Endocrinol 2018; 14:464-475. [PMID: 29946127 DOI: 10.1038/s41574-018-0044-y] [Citation(s) in RCA: 96] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Type 1 diabetes mellitus (T1DM) represents 5-10% of diabetes cases worldwide. The incidence of T1DM is increasing, and there is no immediate prospect of a cure. As such, lifelong management is required, the burden of which is being eased by novel treatment modalities, particularly from the field of diabetes technologies. Continuous glucose monitoring has become the standard of care and includes factory-calibrated subcutaneous glucose monitoring and long-term implantable glucose sensing. In addition, considerable progress has been made in technology-enabled glucose-responsive insulin delivery. The first hybrid insulin-only closed-loop system has been commercialized, and other closed-loop systems are under development, including dual-hormone glucose control systems. This Review focuses on well-established diabetes technologies, including glucose sensing, pen-based insulin delivery, data management and data analytics. We also cover insulin pump therapy, threshold-based suspend, predictive low-glucose suspend and single-hormone and dual-hormone closed-loop systems. Clinical practice recommendations for insulin pump therapy and continuous glucose monitoring are presented, and ongoing research and future prospects are highlighted. We conclude that the management of T1DM is improved by diabetes technology for the benefit of the majority of people with T1DM, their caregivers and guardians and health-care professionals treating patients with T1DM.
Collapse
Affiliation(s)
- Martin Tauschmann
- Wellcome Trust-MRC Institute of Metabolic Science, University of Cambridge, Cambridge, UK
- Department of Paediatrics, University of Cambridge, Cambridge, UK
| | - Roman Hovorka
- Wellcome Trust-MRC Institute of Metabolic Science, University of Cambridge, Cambridge, UK.
- Department of Paediatrics, University of Cambridge, Cambridge, UK.
| |
Collapse
|
21
|
Majeed W, Thabit H. Closed-loop insulin delivery: current status of diabetes technologies and future prospects. Expert Rev Med Devices 2018; 15:579-590. [PMID: 30027775 DOI: 10.1080/17434440.2018.1503530] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Type 1 diabetes is characterised by destruction of pancreatic beta cells, leading to insulin deficiency and hyperglycaemia. The mainstay of treatment remains lifelong insulin therapy as a sustainable cure has as yet proven elusive. The burden of daily management of type 1 diabetes has contributed to suboptimal outcomes for people living with the condition. Innovative technological approaches have been shown to improve glycaemic and patient-related outcomes. AREAS COVERED We discuss recent advances in technologies in type 1 diabetes including closed-loop systems, also known as the 'artificial pancreas. Its various components, technical aspects and limitations are reviewed. We also discuss its advent into clinical practice, and other systems in development. Evidence from clinical studies are summarised. EXPERT COMMENTARY The recent approval of a hybrid closed-loop system for clinical use highlights the significant progress made in this field. Results from clinical studies have shown safety and glycaemic benefit, however challenges remain around improving performance and acceptability. More data is required to establish long-term clinical efficacy and cost-effectiveness, to fulfil the expectations of people with type 1 diabetes.
Collapse
Affiliation(s)
- Waseem Majeed
- a Manchester Academic Health Science Centre , Manchester University Hospitals NHS Foundation Trust , Manchester , UK
| | - Hood Thabit
- a Manchester Academic Health Science Centre , Manchester University Hospitals NHS Foundation Trust , Manchester , UK.,b Division of Diabetes, Endocrinology and Gastroenterology, Faculty of Biology, Medicine and Health , University of Manchester , Manchester , UK
| |
Collapse
|
22
|
Abstract
PURPOSE OF REVIEW The complexity of modern insulin-based therapy for type I and type II diabetes mellitus and the risks associated with excursions in blood-glucose concentration (hyperglycemia and hypoglycemia) have motivated the development of 'smart insulin' technologies (glucose-responsive insulin, GRI). Such analogs or delivery systems are entities that provide insulin activity proportional to the glycemic state of the patient without external monitoring by the patient or healthcare provider. The present review describes the relevant historical background to modern GRI technologies and highlights three distinct approaches: coupling of continuous glucose monitoring (CGM) to deliver devices (algorithm-based 'closed-loop' systems), glucose-responsive polymer encapsulation of insulin, and molecular modification of insulin itself. RECENT FINDINGS Recent advances in GRI research utilizing each of the three approaches are illustrated; these include newly developed algorithms for CGM-based insulin delivery systems, glucose-sensitive modifications of existing clinical analogs, newly developed hypoxia-sensitive polymer matrices, and polymer-encapsulated, stem-cell-derived pancreatic β cells. SUMMARY Although GRI technologies have yet to be perfected, the recent advances across several scientific disciplines that are described in this review have provided a path towards their clinical implementation.
Collapse
Affiliation(s)
- Nischay K. Rege
- Department of Biochemistry and Medical Scientist Training Program, Case Western Reserve University
| | | | - Michael A. Weiss
- Chairman of Institute for Therapeutic Protein Design, Departments of Biomedical Engineering, Biochemistry, and Medicine
| |
Collapse
|