1
|
Huang J, Günther B, Achterhold K, Dierolf M, Pfeiffer F. Simultaneous two-color X-ray absorption spectroscopy using Laue crystals at an inverse-compton scattering X-ray facility. JOURNAL OF SYNCHROTRON RADIATION 2021; 28:1874-1880. [PMID: 34738942 PMCID: PMC8570203 DOI: 10.1107/s1600577521009437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Accepted: 09/09/2021] [Indexed: 06/13/2023]
Abstract
X-ray absorption spectroscopy (XAS) is an element-selective technique that provides electronic and structural information of materials and reveals the essential mechanisms of the reactions involved. However, the technique is typically conducted at synchrotrons and usually only probes one element at a time. In this paper, a simultaneous two-color XAS setup at a laboratory-scale synchrotron facility is proposed based on inverse Compton scattering (ICS) at the Munich Compact Light Source (MuCLS), which is based on inverse Compton scattering (ICS). The setup utilizes two silicon crystals in a Laue geometry. A proof-of-principle experiment is presented where both silver (Ag) and palladium (Pd) K-edge X-ray absorption near-edge structure spectra were simultaneously measured. The simplicity of the setup facilitates its migration to other ICS facilities or maybe to other X-ray sources (e.g. a bending-magnet beamline). Such a setup has the potential to study reaction mechanisms and synergistic effects of chemical systems containing multiple elements of interest, such as a bimetallic catalyst system.
Collapse
Affiliation(s)
- Juanjuan Huang
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748 Garching, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Benedikt Günther
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748 Garching, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Klaus Achterhold
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748 Garching, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Martin Dierolf
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748 Garching, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748 Garching, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences, Technical University of Munich, 85748 Garching, Germany
- Munich Institute of Biomedical Engineering, Technical University of Munich, 85748 Garching, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, 81675 München, Germany
- Institute for Advanced Study, Technical University of Munich, 85748 Garching, Germany
| |
Collapse
|
2
|
Montgomery JB, Klein M, Boire JR, Beck C, Häusermann D, Maksimenko A, Hall CJ. Synchrotron CT of an equine digit at the Australian Synchrotron Imaging and Medical Beamline. JOURNAL OF SYNCHROTRON RADIATION 2021; 28:1769-1777. [PMID: 34738930 PMCID: PMC8570209 DOI: 10.1107/s1600577521010493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 10/10/2021] [Indexed: 06/13/2023]
Abstract
Laminitis is an extremely painful and debilitating condition of horses that can affect their athletic ability and even quality of life. The current gold standard for assessment of laminar tissue is histology, which is the only modality that enables detailed visualization of the lamina. Histology requires dissection of the hoof and therefore can only represent one specific time point. The superior spatial and contrast resolution of synchrotron computed tomography (sCT), when compared with readily available imaging modalities, such as radiographs and conventional CT, provides an opportunity for detailed studies of the lamina without the need for hoof dissection and histological assessment. If the resolution of histology can be matched or even approached, dynamic events, such as laminar blood flow, could also be studied on the microscopic tissue level. To investigate this possible application of sCT further, two objectives are presented: (i) to develop a protocol for sCT of an equine digit using cadaver limbs and (ii) to apply the imaging protocol established during (i) for sCT imaging of the vasculature within the foot using an ex vivo perfusion system to deliver the vascular contrast. The hypotheses were that sCT would allow sufficient resolution for detailed visualization to the level of the secondary lamellae and associated capillaries within the equine digit. Synchrotron CT enabled good visualization of the primary lamellae (average length 3.6 mm) and the ex vivo perfusion system was able to deliver vascular contrast agent to the vessels of the lamina. The individual secondary lamellae (average length 0.142 mm) could not be seen in detail, although differentiation between primary and secondary lamellae was achieved. This approaches, but does not yet reach, the current gold standard, histology, for assessment of the lamellae; however, with further refinement of this imaging technique, improved resolution may be accomplished in future studies.
Collapse
Affiliation(s)
- J. B. Montgomery
- Department of Large Animal Clinical Sciences, University of Saskatchewan, Saskatoon, SK S7N 5B4, Canada
- Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, SK S7N 5B4, Canada
| | - M. Klein
- Imaging and Medical Beamline, Australian Synchrotron (ANSTO), Wurundjeri Country, Clayton, VIC 3168, Australia
| | - J. R. Boire
- RMD Engineering Inc., Saskatoon, SK S7K 3J7, Canada
| | - C. Beck
- University of Melbourne, Werribee, VIC 3030, Australia
| | - D. Häusermann
- Imaging and Medical Beamline, Australian Synchrotron (ANSTO), Wurundjeri Country, Clayton, VIC 3168, Australia
| | - A. Maksimenko
- Imaging and Medical Beamline, Australian Synchrotron (ANSTO), Wurundjeri Country, Clayton, VIC 3168, Australia
| | - C. J. Hall
- Imaging and Medical Beamline, Australian Synchrotron (ANSTO), Wurundjeri Country, Clayton, VIC 3168, Australia
| |
Collapse
|
3
|
Qi P, Shi X, Samadi N, Chapman D. Bent Laue crystal anatomy: new insights into focusing and energy-dispersion properties. J Appl Crystallogr 2021. [DOI: 10.1107/s1600576720016428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
X-ray Laue-type monochromators are common and essential optical components at many high-power X-ray facilities, e.g. synchrotron facilities. The X-ray optics of bent Laue crystals is a well developed area. An incident X-ray beam penetrating a bent Laue crystal will result in a diffracted beam with different angles and energies. There is a need for a way of organizing the rays that allows one to sort out the energy and spatial properties of the diffracted beam. The present work introduces a new approach for describing the general behaviour of bent Laue crystals from a ray-tracing point of view. This quasi-monochromatic beam approach provides an intuitive view of bent-crystal diffraction and leads to deeper understanding. It explains the energy and spatial properties of common and special cases of bent Laue optics, predicts phenomena that can improve energy-dispersion-related X-ray imaging techniques and provides a theoretical framework that makes ray-tracing simulation easier to realize.
Collapse
|
4
|
Qi P, Samadi N, Chapman D. X-ray Spectral Imaging Program: XSIP. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:1734-1740. [PMID: 33147202 PMCID: PMC7642969 DOI: 10.1107/s1600577520010838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 08/06/2020] [Indexed: 06/11/2023]
Abstract
Spectral K-edge subtraction imaging and wide-field energy-dispersive X-ray absorption spectroscopy imaging are novel, related, synchrotron imaging techniques for element absorption contrast imaging and element speciation imaging, respectively. These two techniques serve different goals but share the same X-ray optics principles with a bent Laue type monochromator and the same data processing algorithms. As there is a growing interest to implement these novel techniques in synchrotron facilities, Python-based software has been developed to automate the data processing procedures for both techniques. In this paper, the concept of the essential data processing algorithms are explained, the workflow of the software is described, and the main features and some related utilities are introduced.
Collapse
Affiliation(s)
- Peng Qi
- Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, Canada
| | - Nazanin Samadi
- Swiss Light Source, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Dean Chapman
- Anatomy, Physiology and Pharmacology, University of Saskatchewan, Saskatoon, Canada
| |
Collapse
|
5
|
Functional lung imaging with synchrotron radiation: Methods and preclinical applications. Phys Med 2020; 79:22-35. [PMID: 33070047 DOI: 10.1016/j.ejmp.2020.10.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 09/30/2020] [Accepted: 10/03/2020] [Indexed: 01/05/2023] Open
Abstract
Many lung disease processes are characterized by structural and functional heterogeneity that is not directly appreciable with traditional physiological measurements. Experimental methods and lung function modeling to study regional lung function are crucial for better understanding of disease mechanisms and for targeting treatment. Synchrotron radiation offers useful properties to this end: coherence, utilized in phase-contrast imaging, and high flux and a wide energy spectrum which allow the selection of very narrow energy bands of radiation, thus allowing imaging at very specific energies. K-edge subtraction imaging (KES) has thus been developed at synchrotrons for both human and small animal imaging. The unique properties of synchrotron radiation extend X-ray computed tomography (CT) capabilities to quantitatively assess lung morphology, and also to map regional lung ventilation, perfusion, inflammation and biomechanical properties, with microscopic spatial resolution. Four-dimensional imaging, allows the investigation of the dynamics of regional lung functional parameters simultaneously with structural deformation of the lung as a function of time. This review summarizes synchrotron radiation imaging methods and overviews examples of its application in the study of disease mechanisms in preclinical animal models, as well as the potential for clinical translation both through the knowledge gained using these techniques and transfer of imaging technology to laboratory X-ray sources.
Collapse
|
6
|
Wide field imaging energy dispersive X-ray absorption spectroscopy. Sci Rep 2019; 9:17734. [PMID: 31776410 PMCID: PMC6881466 DOI: 10.1038/s41598-019-54287-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Accepted: 11/01/2019] [Indexed: 11/08/2022] Open
Abstract
A new energy dispersive X-ray absorption spectroscopy (EDXAS) method is presented for simultaneous wide-field imaging and transmission X-ray absorption spectroscopy (XAS) to enable rapid imaging and speciation of elements. Based on spectral K-Edge Subtraction imaging (sKES), a bent Laue imaging system diffracting in the vertical plane was developed on a bend magnet beamline for selenium speciation. The high flux and small vertical focus, forming a wide horizontal line beam for projection imaging and computed tomography applications, is achieved by precise matching of lattice plane orientation and crystal surface (asymmetry angle). The condition generating a small vertical focus for imaging also provides good energy dispersion. Details for achieving sufficient energy and spatial resolution are demonstrated for both full field imaging and computed tomography in quantifying selenium chemical species. While this system has lower sensitivity as it uses transmission and may lack the flux and spatial resolution of a dedicated focused beamline system, it has significant potential in rapid screening of heterogeneous biomedical or environmental systems to correlate metal speciation with function.
Collapse
|
7
|
Shi Z, Xie X, Li H, Meng Q, Cong W, Wang G. A Reconfigurable energy-resolving method for a layered edge-on detector. Phys Med Biol 2019; 64:135008. [PMID: 30893656 DOI: 10.1088/1361-6560/ab1149] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Currently, most of the x-ray spectral detectors can extract signals in a set number of energy bins, that inevitably reduces the dynamic range and energy resolution of the imaging system. Inspired by the idea of dynamic thresholding, we previously proposed a pixel architecture and an energy-resolving method for layered edge-on detector. However, the complicated energy exchange mechanism of x-rays in the detector that ultimately affects the practical applications of the layered detectors had not been previously considered. In this study, we modify the energy-depositing model of x-ray photons and propose a reconfigurable energy-resolving method to improve the spectral performance of a layered energy integrating detector. We analyze the errors associated with the energy-resolving process and present our numerical simulation results obtained with energy bins and dynamically changed detection layers to demonstrate the utility and reliability of the proposed method.
Collapse
Affiliation(s)
- Zaifeng Shi
- School of Microelectronics, Tianjin University, Nankai District, Tianjin, People's Republic of China
| | | | | | | | | | | |
Collapse
|
8
|
Panahifar A, Chapman LD, Weber L, Samadi N, Cooper DML. Biodistribution of strontium and barium in the developing and mature skeleton of rats. J Bone Miner Metab 2019; 37:385-398. [PMID: 29923023 DOI: 10.1007/s00774-018-0936-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Accepted: 05/07/2018] [Indexed: 10/28/2022]
Abstract
Bone acts as a reservoir for many trace elements. Understanding the extent and pattern of elemental accumulation in the skeleton is important from diagnostic, therapeutic, and toxicological perspectives. Some elements are simply adsorbed to bone surfaces by electric force and are buried under bone mineral, while others can replace calcium atoms in the hydroxyapatite structure. In this article, we investigated the extent and pattern of skeletal uptake of barium and strontium in two different age groups, growing, and skeletally mature, in healthy rats. Animals were dosed orally for 4 weeks with either strontium chloride or barium chloride or combined. The distribution of trace elements was imaged in 3D using synchrotron K-edge subtraction micro-CT at 13.5 µm resolution and 2D electron probe microanalysis (EPMA). Bulk concentration of the elements in serum and bone (tibiae) was also measured by mass spectrometry to study the extent of uptake. Toxicological evaluation did not show any cardiotoxicity or nephrotoxicity. Both elements were primarily deposited in the areas of active bone turnover such as growth plates and trabecular bone. Barium and strontium concentration in the bones of juvenile rats was 2.3 times higher, while serum levels were 1.4 and 1.5 times lower than adults. In all treatment and age groups, strontium was preferred to barium even though equal molar concentrations were dosed. This study displayed spatial co-localization of barium and strontium in bone for the first time. Barium and strontium can be used as surrogates for calcium to study the pathological changes in animal models of bone disease and to study the effects of pharmaceutical compounds on bone micro-architecture and bone remodeling in high spatial sensitivity and precision.
Collapse
Affiliation(s)
- Arash Panahifar
- Department of Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada.
| | - L Dean Chapman
- Department of Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada
- Canadian Light Source, Saskatoon, SK, Canada
| | - Lynn Weber
- Department of Veterinary Biomedical Sciences, University of Saskatchewan, Saskatoon, SK, Canada
| | - Nazanin Samadi
- Department of Physics and Engineering Physics, College of Arts and Science, University of Saskatchewan, Saskatoon, SK, Canada
| | - David M L Cooper
- Department of Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada
| |
Collapse
|
9
|
Thomlinson W, Elleaume H, Porra L, Suortti P. K-edge subtraction synchrotron X-ray imaging in bio-medical research. Phys Med 2018; 49:58-76. [DOI: 10.1016/j.ejmp.2018.04.389] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 04/12/2018] [Accepted: 04/16/2018] [Indexed: 11/26/2022] Open
|
10
|
Deman P, Tan S, Belev G, Samadi N, Martinson M, Chapman D, Ford NL. Respiratory-gated KES imaging of a rat model of acute lung injury at the Canadian Light Source. JOURNAL OF SYNCHROTRON RADIATION 2017; 24:679-685. [PMID: 28452761 PMCID: PMC5477483 DOI: 10.1107/s160057751700193x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Accepted: 02/06/2017] [Indexed: 05/13/2023]
Abstract
In this study, contrast-enhanced X-ray tomographic imaging for monitoring and quantifying respiratory disease in preclinical rodent models is proposed. A K-edge imaging method has been developed at the Canadian Light Source to very accurately obtain measurements of the concentration of iodinated contrast agent in the pulmonary vasculature and inhaled xenon in the airspaces of rats. To compare the iodine and xenon concentration maps, a scout projection image was acquired to define the region of interest within the thorax for imaging and to ensure the same locations were imaged in each K-edge subtraction (KES) acquisition. A method for triggering image acquisition based on the real-time measurements of respiration was also developed to obtain images during end expiration when the lungs are stationary, in contrast to other previously published studies that alter the respiration to accommodate the image acquisition. In this study, images were obtained in mechanically ventilated animals using physiological parameters at the iodine K-edge in vivo and at the xenon K-edge post mortem (but still under mechanical ventilation). The imaging techniques were performed in healthy Brown Norway rats and in age-matched littermates that had an induced lung injury to demonstrate feasibility of the imaging procedures and the ability to correlate the lung injury and the quantitative measurements of contrast agent concentrations between the two KES images. The respiratory-gated KES imaging protocol can be easily adapted to image during any respiratory phase and is feasible for imaging disease models with compromised lung function.
Collapse
Affiliation(s)
- P. Deman
- Department of Oral Biological and Medical Sciences, The University of British Columbia, Vancouver, BC, Canada V6T1Z3
| | - S. Tan
- Department of Physics and Astronomy, The University of British Columbia, Vancouver, BC, Canada V6T1Z3
| | - G. Belev
- Canadian Light Source, Saskatoon, SK, Canada S7N2V3
| | - N. Samadi
- Department of Physics and Engineering Physics, University of Saskatchewan, Saskatoon, SK, Canada S7N5A9
| | - M. Martinson
- Department of Physics and Engineering Physics, University of Saskatchewan, Saskatoon, SK, Canada S7N5A9
| | - D. Chapman
- Canadian Light Source, Saskatoon, SK, Canada S7N2V3
- Division of Biomedical Engineering, and Department of Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, SK, Canada S7N5A9
| | - N. L. Ford
- Department of Oral Biological and Medical Sciences, The University of British Columbia, Vancouver, BC, Canada V6T1Z3
- Department of Physics and Astronomy, The University of British Columbia, Vancouver, BC, Canada V6T1Z3
| |
Collapse
|
11
|
Bassey B, Martinson M, Samadi N, Belev G, Karanfil C, Qi P, Chapman D. Multiple energy synchrotron biomedical imaging system. Phys Med Biol 2016; 61:8180-8198. [PMID: 27804925 DOI: 10.1088/0031-9155/61/23/8180] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A multiple energy imaging system that can extract multiple endogenous or induced contrast materials as well as water and bone images would be ideal for imaging of biological subjects. The continuous spectrum available from synchrotron light facilities provides a nearly perfect source for multiple energy x-ray imaging. A novel multiple energy x-ray imaging system, which prepares a horizontally focused polychromatic x-ray beam, has been developed at the BioMedical Imaging and Therapy bend magnet beamline at the Canadian Light Source. The imaging system is made up of a cylindrically bent Laue single silicon (5,1,1) crystal monochromator, scanning and positioning stages for the subjects, flat panel (area) detector, and a data acquisition and control system. Depending on the crystal's bent radius, reflection type, and the horizontal beam width of the filtered synchrotron radiation (20-50 keV) used, the size and spectral energy range of the focused beam prepared varied. For example, with a bent radius of 95 cm, a (1,1,1) type reflection and a 50 mm wide beam, a 0.5 mm wide focused beam of spectral energy range 27 keV-43 keV was obtained. This spectral energy range covers the K-edges of iodine (33.17 keV), xenon (34.56 keV), cesium (35.99 keV), and barium (37.44 keV); some of these elements are used as biomedical and clinical contrast agents. Using the developed imaging system, a test subject composed of iodine, xenon, cesium, and barium along with water and bone were imaged and their projected concentrations successfully extracted. The estimated dose rate to test subjects imaged at a ring current of 200 mA is 8.7 mGy s-1, corresponding to a cumulative dose of 1.3 Gy and a dose of 26.1 mGy per image. Potential biomedical applications of the imaging system will include projection imaging that requires any of the extracted elements as a contrast agent and multi-contrast K-edge imaging.
Collapse
Affiliation(s)
- B Bassey
- Physics and Engineering Physics, University of Saskatchewan, Saskatoon, SK, Canada
| | | | | | | | | | | | | |
Collapse
|
12
|
Panahifar A, Samadi N, Swanston TM, Chapman LD, Cooper DML. Spectral K-edge subtraction imaging of experimental non-radioactive barium uptake in bone. Phys Med 2016; 32:1765-1770. [PMID: 27515551 DOI: 10.1016/j.ejmp.2016.07.619] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2016] [Revised: 07/11/2016] [Accepted: 07/25/2016] [Indexed: 12/01/2022] Open
Abstract
PURPOSE To evaluate the feasibility of using non-radioactive barium as a bone tracer for detection with synchrotron spectral K-edge subtraction (SKES) technique. METHODS Male rats of 1-month old (i.e., developing skeleton) and 8-month old (i.e., skeletally mature) were orally dosed with low dose of barium chloride (33mg/kg/day Ba2+) for 4weeks. The fore and hind limbs were dissected for imaging in projection and computed tomography modes at 100μm and 52μm pixel sizes. The SKES method utilizes a single bent Laue monochromator to prepare a 550eV energy spectrum to encompass the K-edge of barium (37.441keV), for collecting both 'above' and 'below' the K-edge data sets in a single scan. RESULTS The SKES has a very good focal size, thus limits the 'crossover' and motion artifacts. In juvenile rats, barium was mostly incorporated in the areas of high bone turnover such as at the growth plate and the trabecular surfaces, but also in the cortical bone as the animals were growing at the time of tracer administration. However, the adults incorporated approximately half the concentration and mainly in the areas where bone remodeling was predominant and occasionally in the periosteal and endosteal layers of the diaphyseal cortical bone. CONCLUSIONS The presented methodology is simple to implement and provides both structural and functional information, after labeling with barium, on bone micro-architecture and thus has great potential for in vivo imaging of pre-clinical animal models of musculoskeletal diseases to better understand their mechanisms and to evaluate the efficacy of pharmaceuticals.
Collapse
Affiliation(s)
- Arash Panahifar
- Department of Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
| | - Nazanin Samadi
- Department of Physics and Engineering Physics, College of Arts and Science, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Treena M Swanston
- Department of Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - L Dean Chapman
- Department of Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, Saskatchewan, Canada; Canadian Light Source, Saskatoon, Saskatchewan, Canada
| | - David M L Cooper
- Department of Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
| |
Collapse
|
13
|
Panahifar A, Swanston TM, Jake Pushie M, Belev G, Chapman D, Weber L, Cooper DML. Three-dimensional labeling of newly formed bone using synchrotron radiation barium K-edge subtraction imaging. Phys Med Biol 2016; 61:5077-5088. [PMID: 27320962 PMCID: PMC5173444 DOI: 10.1088/0031-9155/61/13/5077] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Bone is a dynamic tissue which exhibits complex patterns of growth as well as continuous internal turnover (i.e. remodeling). Tracking such changes can be challenging and thus a high resolution imaging-based tracer would provide a powerful new perspective on bone tissue dynamics. This is, particularly so if such a tracer can be detected in 3D. Previously, strontium has been demonstrated to be an effective tracer which can be detected by synchrotron-based dual energy K-edge subtraction (KES) imaging in either 2D or 3D. The use of strontium is, however, limited to very small sample thicknesses due to its low K-edge energy (16.105 keV) and thus is not suitable for in vivo application. Here we establish proof-of-principle for the use of barium as an alternative tracer with a higher K-edge energy (37.441 keV), albeit for ex vivo imaging at the moment, which enables application in larger specimens and has the potential to be developed for in vivo imaging of preclinical animal models. New bone formation within growing rats in 2D and 3D was demonstrated at the Biomedical Imaging and Therapy bending magnet (BMIT-BM) beamline of the Canadian Light Source synchrotron. Comparative x-ray fluorescence imaging confirmed those patterns of uptake detected by KES. This initial work provides a platform for the further development of this tracer and its exploration of applications for in vivo development.
Collapse
Affiliation(s)
- Arash Panahifar
- Department of Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | | | | | | | | | | | | |
Collapse
|
14
|
Gagnon KB, Caine S, Samadi N, Martinson M, van der Loop M, Alcorn J, Chapman LD, Belev G, Nichol H. Design of a mouse restraint for synchrotron-based computed tomography imaging. JOURNAL OF SYNCHROTRON RADIATION 2015; 22:1297-1300. [PMID: 26289283 DOI: 10.1107/s160057751501036x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 05/29/2015] [Indexed: 06/04/2023]
Abstract
High-resolution computed tomography (CT) imaging of a live animal within a lead-lined synchrotron light hutch presents several unique challenges. In order to confirm that the animal is under a stable plane of anaesthesia, several physiological parameters (e.g. heart rate, arterial oxygen saturation, core body temperature and respiratory rate) must be remotely monitored from outside the imaging hutch. In addition, to properly scan the thoracic region using CT, the animal needs to be held in a vertical position perpendicular to the fixed angle of the X-ray beam and free to rotate 180°-360°. A new X-ray transparent mouse restraint designed and fabricated using computer-aided design software and three-dimensional rapid prototype printing has been successfully tested at the Biomedical Imaging and Therapy bending-magnet (BMIT-BM) beamline at the Canadian Light Source.
Collapse
Affiliation(s)
- Kenneth B Gagnon
- Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada
| | - Sally Caine
- Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada
| | - Nazanin Samadi
- Biomedical Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| | - Mercedes Martinson
- Physics and Engineering Physics, University of Saskatchewan, Saskatoon, SK, Canada
| | - Melanie van der Loop
- Research Services and Ethics Office, University of Saskatchewan, Saskatoon, SK, Canada
| | - Jane Alcorn
- Research Services and Ethics Office, University of Saskatchewan, Saskatoon, SK, Canada
| | - L Dean Chapman
- Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada
| | - George Belev
- Biomedical Imaging and Therapy Beamlines, Canadian Light Source, Saskatoon, SK, Canada
| | - Helen Nichol
- Anatomy and Cell Biology, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada
| |
Collapse
|
15
|
Midgley S, Schleich N. Dual-energy X-ray analysis using synchrotron computed tomography at 35 and 60 keV for the estimation of photon interaction coefficients describing attenuation and energy absorption. JOURNAL OF SYNCHROTRON RADIATION 2015; 22:807-818. [PMID: 25931101 DOI: 10.1107/s1600577515004579] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Accepted: 03/05/2015] [Indexed: 06/04/2023]
Abstract
A novel method for dual-energy X-ray analysis (DEXA) is tested using measurements of the X-ray linear attenuation coefficient μ. The key is a mathematical model that describes elemental cross sections using a polynomial in atomic number. The model is combined with the mixture rule to describe μ for materials, using the same polynomial coefficients. Materials are characterized by their electron density Ne and statistical moments Rk describing their distribution of elements, analogous to the concept of effective atomic number. In an experiment with materials of known density and composition, measurements of μ are written as a system of linear simultaneous equations, which is solved for the polynomial coefficients. DEXA itself involves computed tomography (CT) scans at two energies to provide a system of non-linear simultaneous equations that are solved for Ne and the fourth statistical moment R4. Results are presented for phantoms containing dilute salt solutions and for a biological specimen. The experiment identifies 1% systematic errors in the CT measurements, arising from third-harmonic radiation, and 20-30% noise, which is reduced to 3-5% by pre-processing with the median filter and careful choice of reconstruction parameters. DEXA accuracy is quantified for the phantom as the mean absolute differences for Ne and R4: 0.8% and 1.0% for soft tissue and 1.2% and 0.8% for bone-like samples, respectively. The DEXA results for the biological specimen are combined with model coefficients obtained from the tabulations to predict μ and the mass energy absorption coefficient at energies of 10 keV to 20 MeV.
Collapse
Affiliation(s)
- Stewart Midgley
- School of Physics, Monash University, Clayton, VIC 3080, Australia
| | - Nanette Schleich
- Department of Radiation Therapy, University of Otago, Wellington, New Zealand
| |
Collapse
|
16
|
Martinson M, Samadi N, Bassey B, Gomez A, Chapman D. Phase-preserving beam expander for biomedical X-ray imaging. JOURNAL OF SYNCHROTRON RADIATION 2015; 22:801-806. [PMID: 25931100 PMCID: PMC4416688 DOI: 10.1107/s1600577515004695] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2014] [Accepted: 03/07/2015] [Indexed: 06/04/2023]
Abstract
The BioMedical Imaging and Therapy beamlines at the Canadian Light Source are used by many researchers to capture phase-based imaging data. These experiments have so far been limited by the small vertical beam size, requiring vertical scanning of biological samples in order to image their full vertical extent. Previous work has been carried out to develop a bent Laue beam-expanding monochromator for use at these beamlines. However, the first attempts exhibited significant distortion in the diffraction plane, increasing the beam divergence and eliminating the usefulness of the monochromator for phase-related imaging techniques. Recent work has been carried out to more carefully match the polychromatic and geometric focal lengths in a so-called `magic condition' that preserves the divergence of the beam and enables full-field phase-based imaging techniques. The new experimental parameters, namely asymmetry and Bragg angles, were evaluated by analysing knife-edge and in-line phase images to determine the effect on beam divergence in both vertical and horizontal directions, using the flat Bragg double-crystal monochromator at the beamline as a baseline. The results show that by using the magic condition, the difference between the two monochromator types is less than 10% in the diffraction plane. Phase fringes visible in test images of a biological sample demonstrate that this difference is small enough to enable in-line phase imaging, despite operating at a sub-optimal energy for the wafer and asymmetry angle that was used.
Collapse
Affiliation(s)
- Mercedes Martinson
- Physics and Engineering Physics, University of Saskatchewan, 116 Science Place, Rm 163, Saskatoon, Saskatchewan, Canada S7N 5E2
| | - Nazanin Samadi
- Biomedical Engineering, University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan, Canada S7N 5E5
| | - Bassey Bassey
- Physics and Engineering Physics, University of Saskatchewan, 116 Science Place, Rm 163, Saskatoon, Saskatchewan, Canada S7N 5E2
| | - Ariel Gomez
- Brockhouse Beamlines, Canadian Light Source, 44 Innovation Boulevard, Saskatoon, Saskatchewan, Canada S7N 2V3
| | - Dean Chapman
- Physics and Engineering Physics, University of Saskatchewan, 116 Science Place, Rm 163, Saskatoon, Saskatchewan, Canada S7N 5E2
- Anatomy and Cell Biology, University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan, Canada S7N 5E5
| |
Collapse
|