1
|
Aggas JR, Abasi S, Ton C, Salehi S, Liu R, Brandacher G, Grayson WL, Guiseppi-Elie A. Real-Time Monitoring Using Multiplexed Multi-Electrode Bioelectrical Impedance Spectroscopy for the Stratification of Vascularized Composite Allografts: A Perspective on Predictive Analytics. Bioengineering (Basel) 2023; 10:bioengineering10040434. [PMID: 37106621 PMCID: PMC10135882 DOI: 10.3390/bioengineering10040434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/20/2023] [Accepted: 03/24/2023] [Indexed: 04/29/2023] Open
Abstract
Vascularized composite allotransplantation addresses injuries to complex anatomical structures such as the face, hand, and abdominal wall. Prolonged static cold storage of vascularized composite allografts (VCA) incurs damage and imposes transportation limits to their viability and availability. Tissue ischemia, the major clinical indication, is strongly correlated with negative transplantation outcomes. Machine perfusion and normothermia can extend preservation times. This perspective introduces multiplexed multi-electrode bioimpedance spectroscopy (MMBIS), an established bioanalytical method to quantify the interaction of the electrical current with tissue components, capable of measuring tissue edema, as a quantitative, noninvasive, real-time, continuous monitoring technique to provide crucially needed assessment of graft preservation efficacy and viability. MMBIS must be developed, and appropriate models explored to address the highly complex multi-tissue structures and time-temperature changes of VCA. Combined with artificial intelligence (AI), MMBIS can serve to stratify allografts for improvement in transplantation outcomes.
Collapse
Affiliation(s)
- John R Aggas
- Bioelectronics, Biosensors and Biochips (C3B®), Department of Biomedical Engineering, Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA
- Test Development, Roche Diagnostics, 9115 Hague Road, Indianapolis, IN 46256, USA
| | - Sara Abasi
- Bioelectronics, Biosensors and Biochips (C3B®), Department of Biomedical Engineering, Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA
- Media and Metabolism, Wildtype, Inc., 2325 3rd St., San Francisco, CA 94107, USA
| | - Carolyn Ton
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Sara Salehi
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Renee Liu
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Gerald Brandacher
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
- Department of Plastic & Reconstructive Surgery, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Warren L Grayson
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
- Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Institute for Nanobiotechnology, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Anthony Guiseppi-Elie
- Bioelectronics, Biosensors and Biochips (C3B®), Department of Biomedical Engineering, Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA
- Department of Cardiovascular Sciences, Houston Methodist Institute for Academic Medicine and Houston Methodist Research Institute, 6670 Bertner Ave., Houston, TX 77030, USA
- ABTECH Scientific, Inc., Biotechnology Research Park, 800 East Leigh Street, Richmond, VA 23219, USA
| |
Collapse
|
2
|
Abasi S, Aggas JR, Garayar-Leyva GG, Walther BK, Guiseppi-Elie A. Bioelectrical Impedance Spectroscopy for Monitoring Mammalian Cells and Tissues under Different Frequency Domains: A Review. ACS MEASUREMENT SCIENCE AU 2022; 2:495-516. [PMID: 36785772 PMCID: PMC9886004 DOI: 10.1021/acsmeasuresciau.2c00033] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2022] [Revised: 08/05/2022] [Accepted: 08/05/2022] [Indexed: 05/13/2023]
Abstract
Bioelectrical impedance analysis and bioelectrical impedance spectroscopy (BIA/BIS) of tissues reveal important information on molecular composition and physical structure that is useful in diagnostics and prognostics. The heterogeneity in structural elements of cells, tissues, organs, and the whole human body, the variability in molecular composition arising from the dynamics of biochemical reactions, and the contributions of inherently electroresponsive components, such as ions, proteins, and polarized membranes, have rendered bioimpedance challenging to interpret but also a powerful evaluation and monitoring technique in biomedicine. BIA/BIS has thus become the basis for a wide range of diagnostic and monitoring systems such as plethysmography and tomography. The use of BIA/BIS arises from (i) being a noninvasive and safe measurement modality, (ii) its ease of miniaturization, and (iii) multiple technological formats for its biomedical implementation. Considering the dependency of the absolute and relative values of impedance on frequency, and the uniqueness of the origins of the α-, β-, δ-, and γ-dispersions, this targeted review discusses biological events and underlying principles that are employed to analyze the impedance data based on the frequency range. The emergence of BIA/BIS in wearable devices and its relevance to the Internet of Medical Things (IoMT) are introduced and discussed.
Collapse
Affiliation(s)
- Sara Abasi
- Center
for Bioelectronics, Biosensors and Biochips (C3B®), Department
of Biomedical Engineering, Texas A&M
University, 400 Bizzell Street, College Station, Texas 77843, United States
- Cell
Culture Media Services, Cytiva, 100 Results Way, Marlborough, Massachusetts 01752, United States
| | - John R. Aggas
- Center
for Bioelectronics, Biosensors and Biochips (C3B®), Department
of Biomedical Engineering, Texas A&M
University, 400 Bizzell Street, College Station, Texas 77843, United States
- Test
Development, Roche Diagnostics, 9115 Hague Road, Indianapolis, Indiana 46256, United
States
| | - Guillermo G. Garayar-Leyva
- Center
for Bioelectronics, Biosensors and Biochips (C3B®), Department
of Biomedical Engineering, Texas A&M
University, 400 Bizzell Street, College Station, Texas 77843, United States
- Department
of Electrical and Computer Engineering, Texas A&M University, 400 Bizzell Street, College Station, Texas 77843, United States
| | - Brandon K. Walther
- Center
for Bioelectronics, Biosensors and Biochips (C3B®), Department
of Biomedical Engineering, Texas A&M
University, 400 Bizzell Street, College Station, Texas 77843, United States
- Department
of Cardiovascular Sciences, Houston Methodist
Institute for Academic Medicine and Houston Methodist Research Institute, 6670 Bertner Avenue, Houston, Texas 77030, United States
| | - Anthony Guiseppi-Elie
- Center
for Bioelectronics, Biosensors and Biochips (C3B®), Department
of Biomedical Engineering, Texas A&M
University, 400 Bizzell Street, College Station, Texas 77843, United States
- Department
of Electrical and Computer Engineering, Texas A&M University, 400 Bizzell Street, College Station, Texas 77843, United States
- Department
of Cardiovascular Sciences, Houston Methodist
Institute for Academic Medicine and Houston Methodist Research Institute, 6670 Bertner Avenue, Houston, Texas 77030, United States
- ABTECH Scientific,
Inc., Biotechnology Research Park, 800 East Leigh Street, Richmond, Virginia 23219, United
States
- . Tel.: +1(804)347.9363.
Fax: +1(804)347.9363
| |
Collapse
|
3
|
Murthy R, Lin YH, Shin K, Mueller JL. A DIRECT RECONSTRUCTION ALGORITHM FOR THE ANISOTROPIC INVERSE CONDUCTIVITY PROBLEM BASED ON CALDERÓN'S METHOD IN THE PLANE. INVERSE PROBLEMS 2020; 36:125008. [PMID: 33353992 PMCID: PMC7751953 DOI: 10.1088/1361-6420/abbe5f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A direct reconstruction algorithm based on Calderón's linearization method for the reconstruction of isotropic conductivities is proposed for anisotropic conductivities in two-dimensions. To overcome the non-uniqueness of the anisotropic inverse conductivity problem, the entries of the unperturbed anisotropic tensors are assumed known a priori, and it remains to reconstruct the multiplicative scalar field. The quasi-conformal map in the plane facilitates the Calderón-based approach for anisotropic conductivities. The method is demonstrated on discontinuous radially symmetric conductivities of high and low contrast.
Collapse
Affiliation(s)
- Rashmi Murthy
- Department of Mathematics, University of Helsinki, Finland
| | - Yi-Hsuan Lin
- Department of Applied Mathematics, National Chiao Tung University, Hsinchu, Taiwan
| | - Kwancheol Shin
- Department of Mathematics, Colorado State University, USA
| | - Jennifer L Mueller
- Department of Mathematics and School of Biomedical Engineering, Colorado State University, USA
| |
Collapse
|
4
|
Padilha Leitzke J, Zangl H. A Review on Electrical Impedance Tomography Spectroscopy. SENSORS 2020; 20:s20185160. [PMID: 32927685 PMCID: PMC7571205 DOI: 10.3390/s20185160] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2020] [Revised: 09/04/2020] [Accepted: 09/05/2020] [Indexed: 11/24/2022]
Abstract
Electrical Impedance Tomography Spectroscopy (EITS) enables the reconstruction of material distributions inside an object based on the frequency-dependent characteristics of different substances. In this paper, we present a review of EITS focusing on physical principles of the technology, sensor geometries, existing measurement systems, reconstruction algorithms, and image representation methods. In addition, a novel imaging method is proposed which could fill some of the gaps found in the literature. As an example of an application, EITS of ice and water mixtures is used.
Collapse
|
5
|
Jiang YD, Soleimani M. Capacitively Coupled Electrical Impedance Tomography for Brain Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:2104-2113. [PMID: 30703015 DOI: 10.1109/tmi.2019.2895035] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Electrical impedance tomography (EIT) is considered as a potential candidate for brain stroke imaging due to its compactness and potential use in bedside and emergency settings. The electrode-skin contact impedance and low conductivity of skull pose some practical challenges to the EIT head imaging. This paper studies the application of capacitively coupled electrical impedance tomography (CCEIT) in brain imaging for the first time. CCEIT is a new contactless EIT technique which uses voltage excitation without direct contact with the skin, as oppose to directly injecting the current to the skin in EIT. Because the safety issue of a new technique should be strictly treated, simulation work based on a simplified head model was carried out to investigate the safety aspects of CCEIT. By comparing with the standard EIT excited by a typical safe current level used in brain imaging, the safe excitation reference of CCEIT is obtained. This is done by comparing the maximum level of internal electrical field (internal current density) of EIT and that of CCEIT. Simulation results provide useful knowledge of excitation signal level of CCEIT and also show a critical comparison with traditional EIT. Practical experiments were carried out with a 12-electrode CCEIT phantom, saline, and carrot samples. Experimental results show the feasibility and potential of CCEIT for stroke imaging. In this paper, the anomaly diameter resolution is 10 mm (1/18 of the phantom diameter), which indicates that small-volume stroke could be detected. This is achieved by a low excitation voltage of 1 V, showing the possibility of even better performance when higher but yet safe level of excitation voltages is used.
Collapse
|
6
|
singh G, Anand S, Lall B, Srivastava A, Singh V. A Low-Cost Portable Wireless Multi-frequency Electrical Impedance Tomography System. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2019. [DOI: 10.1007/s13369-018-3435-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
7
|
Yin W, Lu M, Tang J, Zhao Q, Zhang Z, Li K, Han Y, Peyton A. Custom edge-element FEM solver and its application to eddy-current simulation of realistic 2M-element human brain phantom. Bioelectromagnetics 2018; 39:604-616. [PMID: 30289993 DOI: 10.1002/bem.22148] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2018] [Accepted: 09/24/2018] [Indexed: 11/11/2022]
Abstract
Extensive research papers of three-dimensional computational techniques are widely used for the investigation of human brain pathophysiology. Eddy current analyzing could provide an indication of conductivity change within a biological body. A significant obstacle to current trend analyses is the development of a numerically stable and efficiency-finite element scheme that performs well at low frequency and does not require a large number of degrees of freedom. Here, a custom finite element method (FEM) solver based on edge elements is proposed using the weakly coupled theory, which separates the solution into two steps. First, the background field (the magnetic vector potential on each edge) is calculated and stored. Then, the electric scalar potential on each node is obtained by FEM based on Galerkin formulations. Consequently, the electric field and eddy current distribution in the object can be obtained. This solver is more efficient than typical commercial solvers since it reduces the vector eddy current equation to a scalar one, and reduces the meshing domain to just the eddy current region. It can therefore tackle complex eddy current calculations for models with much larger numbers of elements, such as those encountered in eddy current computation in biological tissues. An example is presented with a realistic human brain mesh of 2 million elements. In addition, with this solver, the equivalent magnetic field induced from the excitation coil is applied, and therefore there is no need to mesh the excitation coil. In combination, these significantly increase the efficiency of the solver. Bioelectromagnetics. 39:604-616, 2018. © 2018 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Wuliang Yin
- School of Instrument and Electronics, North University of China, Taiyuan, Shanxi, China.,School of Electrical and Electronic Engineering, University of Manchester, Manchester, United Kingdom
| | - Mingyang Lu
- School of Electrical and Electronic Engineering, University of Manchester, Manchester, United Kingdom
| | - Jiawei Tang
- School of Electrical and Electronic Engineering, University of Manchester, Manchester, United Kingdom
| | - Qian Zhao
- College of Engineering, Qufu Normal University, Shandong, China
| | - Zhijie Zhang
- School of Instrument and Electronics, North University of China, Taiyuan, Shanxi, China
| | - Kai Li
- School of Instrument and Electronics, North University of China, Taiyuan, Shanxi, China
| | - Yan Han
- School of Information and Communication Engineering, North University of China, Taiyuan, China
| | - Anthony Peyton
- School of Electrical and Electronic Engineering, University of Manchester, Manchester, United Kingdom
| |
Collapse
|
8
|
Singh G, Anand S, Lall B, Srivastava A, Singh V. Low-cost multifrequency electrical impedance-based system (MFEIBS) for clinical imaging: design and performance evaluation. J Med Eng Technol 2018; 42:274-289. [PMID: 30019971 DOI: 10.1080/03091902.2018.1478008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Electrical impedance tomography (EIT) is an upcoming and capable imaging modality used for clinical imaging. It is non-invasive, non-ionising and an inexpensive technique. This paper explains the designing and the analysis of a low-cost multifrequency electrical impedance-based system (MFEIBS) having a flexible mechanism of interfacing up to 32 electrodes, suitable for 1 kHz-2 MHz. Various indicators to check the performance of the EIT system were evaluated and presented here. The performance of VCO and VCCS was measured up to 2 MHz. SNR was measured with saline phantom and its mean value is 74 dB for the complete bandwidth. Different combinations of resistors and capacitors were used to find the accuracy of the system, and relative error was less than 0.55% for the entire range. CMRR of the system was calculated and it was found to be maximum 85 dB at 1 kHz frequency. A 16-electrode circular plastic phantom having a diameter of 18 cm was established and connected with a simple MFEIBS. Obtained surface potential was applied to the computer used for image formation using NI USB-6259, 16-bit, 1.25 MS/s M Series High-speed DAQ. Images reconstructed using the system presented in this paper was generated from a 16-electrode plastic phantom filled with NaCl up to 1.2 cm height.
Collapse
Affiliation(s)
- Gurmeet Singh
- a Indian Institute of Technology , New Delhi , India.,b Guru Tegh Bahadur Institute of Technology , New Delhi , India
| | - Sneh Anand
- a Indian Institute of Technology , New Delhi , India.,c All India Institute of Medical Sciences , New Delhi , India
| | - Brejesh Lall
- a Indian Institute of Technology , New Delhi , India
| | | | - Vaneet Singh
- b Guru Tegh Bahadur Institute of Technology , New Delhi , India
| |
Collapse
|
9
|
Understanding the Pathological Basis of Neurological Diseases Through Diagnostic Platforms Based on Innovations in Biomedical Engineering: New Concepts and Theranostics Perspectives. MEDICINES 2018; 5:medicines5010022. [PMID: 29495320 PMCID: PMC5874587 DOI: 10.3390/medicines5010022] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/01/2018] [Revised: 02/14/2018] [Accepted: 02/20/2018] [Indexed: 02/07/2023]
Abstract
The pace of advancement of genomics and proteomics together with the recent understanding of the molecular basis behind rare diseases could lead in the near future to significant advances in the diagnosing and treating of many pathological conditions. Innovative diagnostic platforms based on biomedical engineering (microdialysis and proteomics, biochip analysis, non-invasive impedance spectroscopy, etc.) are introduced at a rapid speed in clinical practice: this article primarily aims to highlight how such platforms will advance our understanding of the pathological basis of neurological diseases. An overview of the clinical challenges and regulatory hurdles facing the introduction of such platforms in clinical practice, as well as their potential impact on patient management, will complement the discussion on foreseeable theranostic perspectives. Indeed, the techniques outlined in this article are revolutionizing how we (1) identify biomarkers that better define the diagnostic criteria of any given disease, (2) develop research models, and (3) exploit the externalities coming from innovative pharmacological protocols (i.e., those based on monoclonal antibodies, nanodrugs, etc.) meant to tackle the molecular cascade so far identified.
Collapse
|
10
|
Yang Y, Jia J. A multi-frequency electrical impedance tomography system for real-time 2D and 3D imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2017; 88:085110. [PMID: 28863695 DOI: 10.1063/1.4999359] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This paper presents the design and evaluation of a configurable, fast multi-frequency Electrical Impedance Tomography (mfEIT) system for real-time 2D and 3D imaging, particularly for biomedical imaging. The system integrates 32 electrode interfaces and the current frequency ranges from 10 kHz to 1 MHz. The system incorporates the following novel features. First, a fully adjustable multi-frequency current source with current monitoring function is designed. Second, a flexible switching scheme is developed for arbitrary sensing configuration and a semi-parallel data acquisition architecture is implemented for high-frame-rate data acquisition. Furthermore, multi-frequency digital quadrature demodulation is accomplished in a high-capacity Field Programmable Gate Array. At last, a 3D imaging software, visual tomography, is developed for real-time 2D and 3D image reconstruction, data analysis, and visualization. The mfEIT system is systematically tested and evaluated from the aspects of signal to noise ratio (SNR), frame rate, and 2D and 3D multi-frequency phantom imaging. The highest SNR is 82.82 dB on a 16-electrode sensor. The frame rate is up to 546 fps at serial mode and 1014 fps at semi-parallel mode. The evaluation results indicate that the presented mfEIT system is a powerful tool for real-time 2D and 3D imaging.
Collapse
Affiliation(s)
- Yunjie Yang
- Agile Tomography Group, School of Engineering, The University of Edinburgh, Edinburgh EH9 3JL, United Kingdom
| | - Jiabin Jia
- Agile Tomography Group, School of Engineering, The University of Edinburgh, Edinburgh EH9 3JL, United Kingdom
| |
Collapse
|
11
|
Nissinen A, Kaipio JP, Vauhkonen M, Kolehmainen V. Contrast enhancement in EIT imaging of the brain. Physiol Meas 2015; 37:1-24. [PMID: 26642274 DOI: 10.1088/0967-3334/37/1/1] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We consider electrical impedance tomography (EIT) imaging of the brain. The brain is surrounded by the poorly conducting skull which has low conductivity compared to the brain. The skull layer causes a partial shielding effect which leads to weak sensitivity for the imaging of the brain tissue. In this paper we propose an approach based on the Bayesian approximation error approach, to enhance the contrast in brain imaging. With this approach, both the (uninteresting) geometry and the conductivity of the skull are embedded in the approximation error statistics, which leads to a computationally efficient algorithm that is able to detect features such as internal haemorrhage with significantly increased sensitivity and specificity. We evaluate the approach with simulations and phantom data.
Collapse
Affiliation(s)
- A Nissinen
- Department of Applied Physics, University of Eastern Finland, PO Box 1627, FIN-70211 Kuopio, Finland
| | | | | | | |
Collapse
|
12
|
Jang J, Seo JK. Detection of admittivity anomaly on high-contrast heterogeneous backgrounds using frequency difference EIT. Physiol Meas 2015; 36:1179-92. [PMID: 26008619 DOI: 10.1088/0967-3334/36/6/1179] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This paper describes a multiple background subtraction method in frequency difference electrical impedance tomography (fdEIT) to detect an admittivity anomaly from a high-contrast background conductivity distribution. The proposed method expands the use of the conventional weighted frequency difference EIT method, which has been used limitedly to detect admittivity anomalies in a roughly homogeneous background. The proposed method can be viewed as multiple weighted difference imaging in fdEIT. Although the spatial resolutions of the output images by fdEIT are very low due to the inherent ill-posedness, numerical simulations and phantom experiments of the proposed method demonstrate its feasibility to detect anomalies. It has potential application in stroke detection in a head model, which is highly heterogeneous due to the skull.
Collapse
Affiliation(s)
- J Jang
- Computational Science and Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Korea
| | | |
Collapse
|
13
|
|
14
|
Exploratory study on the methodology of fast imaging of unilateral stroke lesions by electrical impedance asymmetry in human heads. ScientificWorldJournal 2014; 2014:534012. [PMID: 25006594 PMCID: PMC4060593 DOI: 10.1155/2014/534012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Accepted: 04/09/2014] [Indexed: 11/29/2022] Open
Abstract
Stroke has a high mortality and disability rate and should be rapidly diagnosed to improve prognosis. Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices. Based on the mechanism that the electrical impedance of the two hemispheres of a normal human head is basically symmetrical and a stroke can alter this symmetry, a fast electrical impedance imaging method called symmetrical electrical impedance tomography (SEIT) is proposed. In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs. The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke.
Collapse
|
15
|
Bonmassar G, Lev MH. Improved Sensing Pulses for Increased Human Head Depth Measurement Sensitivity With Electrical Impedance Spectroscopy. IEEE Trans Biomed Eng 2013; 60:3306-13. [DOI: 10.1109/tbme.2013.2280877] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
16
|
Manwaring PK, Moodie KL, Hartov A, Manwaring KH, Halter RJ. Intracranial electrical impedance tomography: a method of continuous monitoring in an animal model of head trauma. Anesth Analg 2013; 117:866-875. [PMID: 23842194 DOI: 10.1213/ane.0b013e318290c7b7] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a method that can render continuous graphical cross-sectional images of the brain's electrical properties. Because these properties can be altered by variations in water content, shifts in sodium concentration, bleeding, and mass deformation, EIT has promise as a sensitive instrument for head injury monitoring to improve early recognition of deterioration and to observe the benefits of therapeutic intervention. This study presents a swine model of head injury used to determine the detection capabilities of an inexpensive bedside EIT monitoring system with a novel intracranial pressure (ICP)/EIT electrode combination sensor on induced intraparenchymal mass effect, intraparenchymal hemorrhage, and cessation of brain blood flow. Conductivity difference images are shown in conjunction with ICP data, confirming the effects. METHODS Eight domestic piglets (3-4 weeks of age, mean 10 kg), under general anesthesia, were subjected to 4 injuries: induced intraparenchymal mass effect using an inflated, and later, deflated 0.15-mL Fogarty catheter; hemorrhage by intraparenchymal injection of 1-mL arterial blood; and ischemia/infarction by euthanasia. EIT and ICP data were recorded 10 minutes before inducing the injury until 10 minutes after injury. Continuous EIT and ICP monitoring were facilitated by a ring of circumferentially disposed cranial Ag/AgCl electrodes and 1 intraparenchymal ICP/EIT sensor electrode combination. Data were recorded at 100 Hz. Two-dimensional tomographic conductivity difference (Δσ) images, rendered using data before and after an injury, were displayed in real time on an axial circular mesh. Regions of interest (ROI) within the images were automatically selected as the upper or lower 5% of conductivity data depending on the nature of the injury. Mean Δσ within the ROIs and background were statistically analyzed. ROI Δσ was compared with the background Δσ after an injury event using an unpaired, unequal variance t test. Conductivity change within an ROI after injury was likewise compared with the same ROI before the injury making use of unpaired t tests with unequal variance. RESULTS Eight animal subjects were studied, each undergoing 4 injury events including euthanasia. Changes in conductivity due to injury showed expected pathophysiologic effects in an ROI identified within the middle of the left hemisphere; this localization is reasonable given the actual site of injury (left hemisphere) and spatial warping associated with estimating a 3-dimensional conductivity distribution in 2-dimensional space. Results are shown as mean ± 1 SD. When averaged across all 8 animals, balloon inflation caused the mean Δσ within the ROI to shift by -11.4 ± 10.9 mS/m; balloon deflation by +9.4 ± 8.8 mS/m; blood injection by +19.5 ± 11.5 mS/m; death by -12.6 ± 13.2 mS/m. All induced injuries were detectable to statistical significance (P < 0.0001). CONCLUSION This study confirms that the bedside EIT system with ICP/EIT combination sensor can detect induced trauma. Such a technique may hold promise for further research in the monitoring and management of traumatically brain-injured individuals.
Collapse
Affiliation(s)
- Preston K Manwaring
- From the Thayer School of Engineering and Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire; Department of Neurosurgery, Nemours Children's Hospital, Orlando, Florida; and Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire
| | | | | | | | | |
Collapse
|
17
|
Sanchez B, Louarroudi E, Jorge E, Cinca J, Bragos R, Pintelon R. A new measuring and identification approach for time-varying bioimpedance using multisine electrical impedance spectroscopy. Physiol Meas 2013; 34:339-57. [PMID: 23442821 DOI: 10.1088/0967-3334/34/3/339] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The bioimpedance measurement/identification of time-varying biological systems Z(ω, t) by means of electrical impedance spectroscopy (EIS) is still a challenge today. This paper presents a novel measurement and identification approach, the so-called parametric-in-time approach, valid for time-varying (bio-)impedance systems with a (quasi) periodic character. The technique is based on multisine EIS. Contrary to the widely used nonparametric-in-time strategy, the (bio-)impedance Z(ω, t) is assumed to be time-variant during the measurement interval. Therefore, time-varying spectral analysis tools are required. This new parametric-in-time measuring/identification technique has experimentally been validated through three independent sets of in situ measurements of in vivo myocardial impedance. We show that the time-varying myocardial impedance Z(ω, t) is dominantly periodically time varying (PTV), denoted as ZPTV(ω, t). From the temporal analysis of ZPTV(ω, t), we demonstrate that it is possible to decompose ZPTV(ω, t) into a(n) (in)finite sum of fundamental (bio-)impedance spectra, the so-called harmonic impedance spectra (HIS) Zk(ω)s with [Formula: see text]. This is similar to the well-known Fourier series of a periodic signal, but now understood at the level of a periodic system's frequency response. The HIS Zk(ω)s for [Formula: see text] actually summarize in the bi-frequency (ω, k) domain all the temporal in-cycle information about the periodic changes of Z(ω, t). For the particular case k = 0 (i.e. on the ω-axis), Z0(ω) reflects the mean in-cycle behavior of the time-varying bioimpedance. Finally, the HIS Zk(ω)s are directly identified from noisy current and voltage myocardium measurements at the multisine measurement frequencies (i.e. nonparametric-in-frequency).
Collapse
Affiliation(s)
- B Sanchez
- Electronic and Biomedical Instrumentation Group, Department of Electrical Engineering, Universitat Politecnica de Catalunya (UPC), E-08034 Barcelona, Spain.
| | | | | | | | | | | |
Collapse
|
18
|
Lee E, Ts ME, Seo JK, Woo EJ. Breast EIT using a new projected image reconstruction method with multi-frequency measurements. Physiol Meas 2012; 33:751-65. [PMID: 22532397 DOI: 10.1088/0967-3334/33/5/751] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We propose a new method to produce admittivity images of the breast for the diagnosis of breast cancer using electrical impedance tomography(EIT). Considering the anatomical structure of the breast, we designed an electrode configuration where current-injection and voltage-sensing electrodes are separated in such a way that internal current pathways are approximately along the tangential direction of an array of voltage-sensing electrodes. Unlike conventional EIT imaging methods where the number of injected currents is maximized to increase the total amount of measured data, current is injected only twice between two pairs of current-injection electrodes attached along the circumferential side of the breast. For each current injection, the induced voltages are measured from the front surface of the breast using as many voltage-sensing electrodes as possible. Although this electrode configurational lows us to measure induced voltages only on the front surface of the breast,they are more sensitive to an anomaly inside the breast since such an injected current tends to produce a more uniform internal current density distribution. Furthermore, the sensitivity of a measured boundary voltage between two equipotential lines on the front surface of the breast is improved since those equipotential lines are perpendicular to the primary direction of internal current streamlines. One should note that this novel data collection method is different from those of other frontal plane techniques such as the x-ray projection and T-scan imaging methods because we do not get any data on the plane that is perpendicular to the current flow. To reconstruct admittivity images using two measured voltage data sets, a new projected image reconstruction algorithm is developed. Numerical simulations demonstrate the frequency-difference EIT imaging of the breast. The results show that the new method is promising to accurately detect and localize small anomalies inside the breast.
Collapse
Affiliation(s)
- Eunjung Lee
- Department of Computational Science and Engineering, Yonsei University, Seoul, Korea.
| | | | | | | |
Collapse
|
19
|
Seoane F, Ward LC, Lindecrantz K, Lingwood BE. Automated criterion-based analysis for Cole parameters assessment from cerebral neonatal electrical bioimpedance spectroscopy measurements. Physiol Meas 2012; 33:1363-77. [DOI: 10.1088/0967-3334/33/8/1363] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
20
|
Ahn S, Oh TI, Jun SC, Seo JK, Woo EJ. Validation of weighted frequency-difference EIT using a three-dimensional hemisphere model and phantom. Physiol Meas 2011; 32:1663-80. [PMID: 21904022 DOI: 10.1088/0967-3334/32/10/013] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Frequency-difference (FD) electrical impedance tomography (EIT) using a weighted voltage difference has recently been proposed for imaging haemorrhagic stroke, abdominal bleeding and tumors. Although its feasibility was demonstrated through two-dimensional numerical simulations and phantom experiments, we should validate the method in three-dimensional imaging objects. At the same time, we need to investigate its robustness against geometrical modeling errors in boundary shapes and electrode positions. We performed a validation study of the weighted FD method through three-dimensional numerical simulations and phantom experiments. Adopting hemispherical models and phantoms whose admittivity distributions change with frequency, we investigated the performance of the method to detect an anomaly. We found that the simple FD method fails to detect the anomaly, whereas reconstructed images using the weighted FD method clearly visualize the anomaly. The weighted FD method is robust against modeling errors of boundary-shape deformations and displaced electrode positions. We also found that the method is capable of detecting an anomaly surrounded by a shell-shaped obstacle simulating the skull. We propose the weighted FD method for future studies of animal and human experiments.
Collapse
Affiliation(s)
- Sujin Ahn
- School of Information and Communications, Gwangju Institute of Science and Technology, Gwangju, Korea
| | | | | | | | | |
Collapse
|
21
|
Paterno AS, Stiz RA, Bertemes-Filho P. Frequency-domain reconstruction of signals in electrical bioimpedance spectroscopy. Med Biol Eng Comput 2011; 47:1093-102. [PMID: 19820978 DOI: 10.1007/s11517-009-0533-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2009] [Accepted: 09/05/2009] [Indexed: 11/26/2022]
Abstract
The use of an amplitude/phase retrieval algorithm in electrical bioimpedance spectroscopy (EIS) that allows a new technique to reconstruct the impedance spectrum in the frequency-domain is reported. To the authors' knowledge this is the first time the proposed algorithm has been used to calculate the modulus or phase of a bioimpedance in EIS from one of these two experimentally obtained parameters. The algorithmic technique is demonstrated in EIS, when wide-bandwidth amplifiers,phase-detectors, and high speed converters determine spectra over frequencies up to 500 kHz at isolated points in the frequency interval. Simulated data from bioimpedance models (Cole and 2R1C circuit impedance functions) and experimental data from a known electrical impedance are used to show the applicability and limitations of the technique with a phase retrieval and a modulus retrieval algorithm.Results comparing this technique with the Kramers-Kronig technique that retrieves the imaginary part of an impedance from its real part are also discussed.
Collapse
Affiliation(s)
- Aleksander S Paterno
- Department of Electrical Engineering, Santa Catarina State University, Joinville, Brazil.
| | | | | |
Collapse
|
22
|
Harrach B, Seo JK, Woo EJ. Factorization method and its physical justification in frequency-difference electrical impedance tomography. IEEE TRANSACTIONS ON MEDICAL IMAGING 2010; 29:1918-1926. [PMID: 20570764 DOI: 10.1109/tmi.2010.2053553] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Time-difference electrical impedance tomography (tdEIT) requires two data sets measured at two different times. The difference between them is utilized to produce images of time-dependent changes in a complex conductivity distribution inside the human body. Frequency-difference EIT (fdEIT) was proposed to image frequency-dependent changes of a complex conductivity distribution. It has potential applications in tumor and stroke imaging since it can visualize an anomaly without requiring any time-reference data obtained in the absence of an anomaly. In this paper, we provide a rigorous analysis for the detectability of an anomaly based on a constructive and quantitative physical correlation between a measured fdEIT data set and an anomaly. From this, we propose a new noniterative frequency-difference anomaly detection method called the factorization method (FM) and elaborate its physical justification. To demonstrate its practical applicability, we performed fdEIT phantom imaging experiments using a multifrequency EIT system. Applying the FM to measured frequency-difference boundary voltage data sets, we could quantitatively evaluate indicator functions inside the imaging domain, of which values at each position reveal presence or absence of an anomaly. We found that the FM successfully localizes anomalies inside an imaging domain with a frequency-dependent complex conductivity distribution. We propose the new FM as an anomaly detection algorithm in fdEIT for potential applications in tumor and stroke imaging.
Collapse
Affiliation(s)
- Bastian Harrach
- Fakultät für Mathematik, Technische Universität München, 85748 Garching, Germany.
| | | | | |
Collapse
|
23
|
Jun SC, Kuen J, Lee J, Woo EJ, Holder D, Seo JK. Frequency-difference EIT (fdEIT) using weighted difference and equivalent homogeneous admittivity: validation by simulation and tank experiment. Physiol Meas 2009; 30:1087-99. [DOI: 10.1088/0967-3334/30/10/009] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
24
|
Kuen J, Woo EJ, Seo JK. Multi-frequency time-difference complex conductivity imaging of canine and human lungs using the KHU Mark1 EIT system. Physiol Meas 2009; 30:S149-64. [DOI: 10.1088/0967-3334/30/6/s10] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
25
|
Fabrizi L, McEwan A, Oh T, Woo EJ, Holder DS. An electrode addressing protocol for imaging brain function with electrical impedance tomography using a 16-channel semi-parallel system. Physiol Meas 2009; 30:S85-101. [PMID: 19491446 DOI: 10.1088/0967-3334/30/6/s06] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Electrical impedance tomography of brain function poses special problems because applied current is diverted by the resistive skull. In the past, image resolution was maximized with the use of an electrode addressing protocol with widely spaced drive electrode pairs and use of a multiplexer so that many electrode pairs could be flexibly addressed. The purpose of this study was to develop and test an electrode protocol for a 16-channel semi-parallel system which uses parallel recording channels with fixed wiring, the Kyung Hee University (KHU) Mk1. Ten protocols were tested, all addressing pairs of electrodes for recording or current drive, based on recording with a spiral, spiral with suboccipital electrodes (spiral s-o) and zig-zag configurations, and combinations of current injection from electrode pairs at 180 degrees , 120 degrees and 60 degrees . These were compared by assessing the image reconstruction quality of five simulated perturbations in a homogenous model of the human head and of four epileptic foci in an anatomically realistic model in the presence of realistic noise, in terms of localization error, resolution, image distortion and sensitivity in the region of interest. The spiral s-o with current injection at 180 degrees + 120 degrees + 60 degrees gave the best image quality and permitted reconstruction with a localization error of less than 10% of the head diameter. This encourages the view that it might be possible to obtain satisfactory images of focal abnormalities in the human brain with 16 scalp electrodes and improved instrumentation avoiding multiplexers on recording circuits.
Collapse
Affiliation(s)
- L Fabrizi
- Department of Medical Physics and Bioengineering, Malet Place Engineering Building, Gower Street, University College London, London WC1E 6BT, UK.
| | | | | | | | | |
Collapse
|
26
|
|
27
|
Goharian M, Soleimani M, Jegatheesan A, Chin K, Moran GR. A DSP Based Multi-Frequency 3D Electrical Impedance Tomography System. Ann Biomed Eng 2008; 36:1594-603. [DOI: 10.1007/s10439-008-9537-5] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2007] [Accepted: 07/07/2008] [Indexed: 12/01/2022]
|
28
|
Seo JK, Lee J, Kim SW, Zribi H, Woo EJ. Frequency-difference electrical impedance tomography (fdEIT): algorithm development and feasibility study. Physiol Meas 2008; 29:929-44. [DOI: 10.1088/0967-3334/29/8/006] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
29
|
Oh TI, Koo H, Lee KH, Kim SM, Lee J, Kim SW, Seo JK, Woo EJ. Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging. Physiol Meas 2008; 29:295-307. [DOI: 10.1088/0967-3334/29/3/002] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
30
|
Gilad O, Horesh L, Holder DS. Design of electrodes and current limits for low frequency electrical impedance tomography of the brain. Med Biol Eng Comput 2007; 45:621-33. [PMID: 17597329 DOI: 10.1007/s11517-007-0209-7] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2006] [Accepted: 06/05/2007] [Indexed: 10/23/2022]
Abstract
For the novel application of recording of resistivity changes related to neuronal depolarization in the brain with electrical impedance tomography, optimal recording is with applied currents below 100 Hz, which might cause neural stimulation of skin or underlying brain. The purpose of this work was to develop a method for application of low frequency currents to the scalp, which delivered the maximum current without significant stimulation of skin or underlying brain. We propose a recessed electrode design which enabled current injection with an acceptable skin sensation to be increased from 100 muA using EEG electrodes, to 1 mA in 16 normal volunteers. The effect of current delivered to the brain was assessed with an anatomically realistic finite element model of the adult head. The modelled peak cerebral current density was 0.3 A/m(2), which was 5 to 25-fold less than the threshold for stimulation of the brain estimated from literature review.
Collapse
Affiliation(s)
- O Gilad
- Department of Medical Physics and Bioengineering, Malet Place Engineering Building, University College London, Gower Street, London WC1E 6BT, UK.
| | | | | |
Collapse
|
31
|
Oh TI, Woo EJ, Holder D. Multi-frequency EIT system with radially symmetric architecture: KHU Mark1. Physiol Meas 2007; 28:S183-96. [PMID: 17664635 DOI: 10.1088/0967-3334/28/7/s14] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We describe the development of a multi-frequency electrical impedance tomography (EIT) system (KHU Mark1) with a single balanced current source and multiple voltmeters. It was primarily designed for imaging brain function with a flexible strategy for addressing electrodes and a frequency range from 10 Hz-500 kHz. The maximal number of voltmeters is 64, and all of them can simultaneously acquire and demodulate voltage signals. Each voltmeter measures a differential voltage between a pair of electrodes. All voltmeters are configured in a radially symmetric architecture in order to optimize the routing of wires and minimize cross-talk. We adopted several techniques from existing EIT systems including digital waveform generation, a Howland current generator with a generalized impedance converter (GIC), digital phase-sensitive demodulation and tri-axial cables. New features of the KHU Mark1 system include multiple GIC circuits to maximize the output impedance of the current source at multiple frequencies. The voltmeter employs contact impedance measurements, data overflow detection, spike noise rejection, automatic gain control and programmable data averaging. The KHU Mark1 system measures both in-phase and quadrature components of trans-impedances. By using a script file describing an operating mode, the system setup can be easily changed. The performance of the developed multi-frequency EIT system was evaluated in terms of a common-mode rejection ratio, signal-to-noise ratio, linearity error and reciprocity error. Time-difference and frequency-difference images of a saline phantom with a banana object are presented showing a frequency-dependent complex conductivity of the banana. Future design of a more innovative system is suggested including miniaturization and wireless techniques.
Collapse
Affiliation(s)
- Tong In Oh
- College of Electronics and Information, Kyung Hee University, Korea
| | | | | |
Collapse
|
32
|
Seoane F, Lindecrantz K, Olsson T, Kjellmer I, Flisberg A, Bagenholm R. Brain electrical impedance at various frequencies: the effect of hypoxia. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2004:2322-5. [PMID: 17272194 DOI: 10.1109/iembs.2004.1403674] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Non-invasive multi-frequency measurements of transcephalic impedance, both reactance and resistance, can efficiently detect cell swelling of brain tissue and can be used for early detection of threatening brain damage. We have performed experiments on piglets to monitor transcephalic impedance during hypoxia. The obtained results have confirmed the hypothesis that changes in the size of cells modify the tissue impedance. During tissue inflammation after induced hypoxia, cerebral tissue exhibits changes in both reactance and resistance. Those changes are remarkably high, up to 71% over the baseline, and easy to measure especially at certain frequencies. A better understanding of the electrical behaviour of cerebral tissue during cell swelling would lead us to develop effective non-invasive clinical tools and methods for early diagnosis of cerebral edema and brain damage prevention.
Collapse
Affiliation(s)
- F Seoane
- School of Engineering, University College of Borås, Borås, Sweden
| | | | | | | | | | | |
Collapse
|
33
|
Brown BH, Gonzalez-Correa CA, Bremner J, Tidy JA. Impedance spectral measurements made through a membrane infection barrier. Med Biol Eng Comput 2006; 44:1085-91. [PMID: 17093953 DOI: 10.1007/s11517-006-0126-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2006] [Accepted: 10/10/2006] [Indexed: 10/23/2022]
Abstract
Impedance spectra of superficial tissues can be used to detect pre-malignant changes in the cervix but require electrical contact to be made between a probe and the tissue. Using a membrane which is permeable to ions but forms a barrier to agents of infection should enable impedance spectra to be measured without causing an infection risk to the patient. The properties required of such a membrane are considered and measurements on two suitable membranes are presented. It is shown that impedance spectra can be measured through a thin natural cellulose based membrane (Cuprophan) and that these are not significantly different from directly measured spectra. The ability of the membranes to block a virus is tested using expired polio virus vaccine.
Collapse
Affiliation(s)
- Brian H Brown
- Medical Physics and Clinical Engineering, University of Sheffield, Royal Hallamshire Hospital, Sheffield S102JF, UK.
| | | | | | | |
Collapse
|
34
|
McEwan A, Romsauerova A, Yerworth R, Horesh L, Bayford R, Holder D. Design and calibration of a compact multi-frequency EIT system for acute stroke imaging. Physiol Meas 2006; 27:S199-210. [PMID: 16636411 DOI: 10.1088/0967-3334/27/5/s17] [Citation(s) in RCA: 91] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A new, compact UCLH Mk 2.5 EIT system has been developed and calibrated for EIT imaging of the head. Improvements include increased input and output impedances, increased bandwidth and improved CMRR (80 dB) and linearity over frequencies and load (0.2% on a single channel, +/-0.7% on a saline tank over 20 Hz-256 kHz and 10-65 Omega). The accuracy of the system is sufficient to image severe acute stroke according to the specification from recent detailed anatomical modelling (Horesh et al 2005 3rd European Medical and Biological Engineering Conference EMBEC'05). A preliminary human study has validated the main specifications of the modelling, the range of trans-impedance from the head (8-70 Omega) using a 32 electrode, 258 combination protocol and contact impedances of 300 Omega to 2.7 kOmega over 20 Hz to 256 kHz.
Collapse
Affiliation(s)
- A McEwan
- Department of Medical Physics and Bioengineering, UCL, London WC1E 6BT, UK.
| | | | | | | | | | | |
Collapse
|
35
|
Romsauerova A, McEwan A, Horesh L, Yerworth R, Bayford RH, Holder DS. Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke, development of an analysis method and calibration. Physiol Meas 2006; 27:S147-61. [PMID: 16636407 DOI: 10.1088/0967-3334/27/5/s13] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
MFEIT (multi-frequency electrical impedance tomography) could distinguish between ischaemic and haemorrhagic stroke and permit the urgent use of thrombolytic drugs in patients with ischaemic stroke. The purpose of this study was to characterize the UCLH Mk 2 MFEIT system, designed for this purpose, with 32 electrodes and a multiplexed 2 kHz to 1.6 MHz single impedance measuring circuit. Data were collected in seven subjects with brain tumours, arteriovenous malformations or chronic stroke, as these resembled the changes in haemorrhagic or ischaemic stroke. Calibration studies indicated that the reliable bandwidth was only 16-64 kHz because of front-end components placed to permit simultaneous EEG recording. In raw in-phase component data, the SD of 16-64 kHz data for one electrode combination across subjects was 2.45 +/- 0.9%, compared to a largest predicted change of 0.35% estimated using the FEM of the head. Using newly developed methods of examining the most sensitive channels from the FEM, and nonlinear imaging constrained to the known site of the lesion, no reproducible changes between pathologies were observed. This study has identified a specification for accuracy in EITS in acute stroke, identified the size of variability in relation to this in human recordings, and presents new methods for analysis of data. Although no reproducible changes were identified, we hope this will provide a foundation for future studies in this demanding but potentially powerful novel application.
Collapse
Affiliation(s)
- A Romsauerova
- Department of Medical Physics and Bioengineering, UCL, London, UK.
| | | | | | | | | | | |
Collapse
|
36
|
Xiao C, Lei Y. Analytical solutions of electric potential and impedance for a multilayered spherical volume conductor excited by time-harmonic electric current source: application in brain EIT. Phys Med Biol 2005; 50:2663-74. [PMID: 15901961 DOI: 10.1088/0031-9155/50/11/015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A model of a multilayered spherical volume conductor with four electrodes is built. In this model, a time-harmonic electric current is injected into the sphere through a pair of drive electrodes, and electric potential is measured by the other pair of measurement electrodes. By solving the boundary value problem of the electromagnetic field, the analytical solutions of electric potential and impedance in the whole conduction region are derived. The theoretical values of electric potential on the surface of the sphere are in good accordance with the experimental results. The analytical solutions are then applied to the simulation of the forward problem of brain electrical impedance tomography (EIT). The results show that, for a real human head, the imaginary part of the electric potential is not small enough to be ignored at above 20 kHz, and there exists an approximate linear relationship between the real and imaginary parts of the electric potential when the electromagnetic parameters of the innermost layer keep unchanged. Increase in the conductivity of the innermost layer leads to a decrease of the magnitude of both real and imaginary parts of the electric potential on the scalp. However, the increase of permittivity makes the magnitude of the imaginary part of the electric potential increase while that of the real part decreases, and vice versa.
Collapse
Affiliation(s)
- Chunyan Xiao
- School of Automation and Electrical Engineering, Beihang University, Beijing 100083, People's Republic of China.
| | | |
Collapse
|
37
|
Holder D, Tidswell T. Electrical impedance tomography of brain function. SERIES IN MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2004. [DOI: 10.1201/9781420034462.ch4] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/02/2022]
|
38
|
Linderholm P, Bertsch A, Renaud P. Resistivity probing of multi-layered tissue phantoms using microelectrodes. Physiol Meas 2004; 25:645-58. [PMID: 15253116 DOI: 10.1088/0967-3334/25/3/005] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We present the use of an array of rectangular microelectrodes to discriminate between different resistivities in a thin, layered sample. Each electrode was 8 mm long and 200 nm thick. The electrode widths ranged from 20 to 500 microm. The electrodes were designed such that all pairs of consecutive electrodes had the same relative geometry, and therefore identical cell constants. A hydrogel-based tissue phantom, made by photopolymerization of 2-hydroxyethyl methacrylate (HEMA), was developed. By changing the hydrogel composition and the ionic strength of the storage medium, the resistivity of the hydrogels could be tuned between 100 omegam and 100 komegam. Using bipolar measurements, the tissue phantoms were characterized in the frequency range from 100 Hz to 30 MHz. The relative resistivity distribution of a three-layered structure composed of 120 microm sheets could be calculated and was shown to agree to within 7% of the bulk measurements. Potential clinical applications for this technique include probing of epithelial tissue and skin cancer screening.
Collapse
|