1
|
Stoddart PR, Begeng JM, Tong W, Ibbotson MR, Kameneva T. Nanoparticle-based optical interfaces for retinal neuromodulation: a review. Front Cell Neurosci 2024; 18:1360870. [PMID: 38572073 PMCID: PMC10987880 DOI: 10.3389/fncel.2024.1360870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Accepted: 03/04/2024] [Indexed: 04/05/2024] Open
Abstract
Degeneration of photoreceptors in the retina is a leading cause of blindness, but commonly leaves the retinal ganglion cells (RGCs) and/or bipolar cells extant. Consequently, these cells are an attractive target for the invasive electrical implants colloquially known as "bionic eyes." However, after more than two decades of concerted effort, interfaces based on conventional electrical stimulation approaches have delivered limited efficacy, primarily due to the current spread in retinal tissue, which precludes high-acuity vision. The ideal prosthetic solution would be less invasive, provide single-cell resolution and an ability to differentiate between different cell types. Nanoparticle-mediated approaches can address some of these requirements, with particular attention being directed at light-sensitive nanoparticles that can be accessed via the intrinsic optics of the eye. Here we survey the available known nanoparticle-based optical transduction mechanisms that can be exploited for neuromodulation. We review the rapid progress in the field, together with outstanding challenges that must be addressed to translate these techniques to clinical practice. In particular, successful translation will likely require efficient delivery of nanoparticles to stable and precisely defined locations in the retinal tissues. Therefore, we also emphasize the current literature relating to the pharmacokinetics of nanoparticles in the eye. While considerable challenges remain to be overcome, progress to date shows great potential for nanoparticle-based interfaces to revolutionize the field of visual prostheses.
Collapse
Affiliation(s)
- Paul R. Stoddart
- School of Science, Computing and Engineering Technologies, Swinburne University of Technology, Hawthorn, VIC, Australia
| | - James M. Begeng
- School of Science, Computing and Engineering Technologies, Swinburne University of Technology, Hawthorn, VIC, Australia
- Department of Biomedical Engineering, Faculty of Engineering & Information Technology, The University of Melbourne, Melbourne, VIC, Australia
| | - Wei Tong
- Department of Biomedical Engineering, Faculty of Engineering & Information Technology, The University of Melbourne, Melbourne, VIC, Australia
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| | - Michael R. Ibbotson
- Department of Biomedical Engineering, Faculty of Engineering & Information Technology, The University of Melbourne, Melbourne, VIC, Australia
| | - Tatiana Kameneva
- School of Science, Computing and Engineering Technologies, Swinburne University of Technology, Hawthorn, VIC, Australia
| |
Collapse
|
2
|
Vėbraitė I, Bar-Haim C, David-Pur M, Hanein Y. Bi-directional electrical recording and stimulation of the intact retina with a screen-printed soft probe: a feasibility study. Front Neurosci 2024; 17:1288069. [PMID: 38264499 PMCID: PMC10804455 DOI: 10.3389/fnins.2023.1288069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Accepted: 12/14/2023] [Indexed: 01/25/2024] Open
Abstract
Introduction Electrophysiological investigations of intact neural circuits are challenged by the gentle and complex nature of neural tissues. Bi-directional electrophysiological interfacing with the retina, in its intact form, is particularly demanding and currently there is no feasible approach to achieve such investigations. Here we present a feasibility study of a novel soft multi-electrode array suitable for bi-directional electrophysiological study of the intact retina. Methods Screen-printed soft electrode arrays were developed and tested. The soft probes were designed to accommodate the curvature of the retina in the eye and offer an opportunity to study the retina in its intact form. Results For the first time, we show both electrical recording and stimulation capabilities from the intact retina. In particular, we demonstrate the ability to characterize retina responses to electrical stimulation and reveal stable, direct, and indirect responses compared with ex-vivo conditions. Discussion These results demonstrate the unique performances of the new probe while also suggesting that intact retinas retain better stability and robustness than ex-vivo retinas making them more suitable for characterizing retina responses to electrical stimulation.
Collapse
Affiliation(s)
- Ieva Vėbraitė
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| | - Chen Bar-Haim
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| | - Moshe David-Pur
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| | - Yael Hanein
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
3
|
Ahn J, Yoo Y, Goo YS. Multiple consecutive-biphasic pulse stimulation improves spatially localized firing of retinal ganglion cells in the degenerate retina. THE KOREAN JOURNAL OF PHYSIOLOGY & PHARMACOLOGY : OFFICIAL JOURNAL OF THE KOREAN PHYSIOLOGICAL SOCIETY AND THE KOREAN SOCIETY OF PHARMACOLOGY 2023; 27:541-553. [PMID: 37884286 PMCID: PMC10613570 DOI: 10.4196/kjpp.2023.27.6.541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 08/08/2023] [Accepted: 08/22/2023] [Indexed: 10/28/2023]
Abstract
Retinal prostheses have shown some clinical success in restoring vision in patients with retinitis pigmentosa. However, the post-implantation visual acuity does not exceed that of legal blindness. The reason for the poor visual acuity might be that (1) degenerate retinal ganglion cells (RGCs) are less responsive to electrical stimulation than normal RGCs, and (2) electrically-evoked RGC spikes show a more widespread not focal response. The single-biphasic pulse electrical stimulation, commonly used in artificial vision, has limitations in addressing these issues. In this study, we propose the benefit of multiple consecutive-biphasic pulse stimulation. We used C57BL/6J mice and C3H/HeJ (rd1) mice for the normal retina and retinal degeneration model. An 8 × 8 multi-electrode array was used to record electrically-evoked RGC spikes. We compared RGC responses when increasing the amplitude of a single biphasic pulse versus increasing the number of consecutive biphasic pulses at the same stimulus charge. Increasing the amplitude of a single biphasic pulse induced more RGC spike firing while the spatial resolution of RGC populations decreased. For multiple consecutive-biphasic pulse stimulation, RGC firing increased as the number of pulses increased, and the spatial resolution of RGC populations was well preserved even up to 5 pulses. Multiple consecutive-biphasic pulse stimulation using two or three pulses in degenerate retinas induced as much RGC spike firing as in normal retinas. These findings suggest that the newly proposed multiple consecutive-biphasic pulse stimulation can improve the visual acuity in prosthesis-implanted patients.
Collapse
Affiliation(s)
- Jungryul Ahn
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju 28644, Korea
| | - Yongseok Yoo
- School of Computer Science and Engineering, Soongsil University, Seoul 06978, Korea
| | - Yong Sook Goo
- Department of Physiology, Chungbuk National University School of Medicine, Cheongju 28644, Korea
| |
Collapse
|
4
|
Peiroten L, Zrenner E, Haq W. Artificial Vision: The High-Frequency Electrical Stimulation of the Blind Mouse Retina Decay Spike Generation and Electrogenically Clamped Intracellular Ca 2+ at Elevated Levels. Bioengineering (Basel) 2023; 10:1208. [PMID: 37892938 PMCID: PMC10604554 DOI: 10.3390/bioengineering10101208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 10/05/2023] [Accepted: 10/13/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND The electrical stimulation (stim) of retinal neurons enables blind patients to experience limited artificial vision. A rapid response outage of the stimulated ganglion cells (GCs) allows for a low visual sensation rate. Hence, to elucidate the underlying mechanism, we investigated different stim parameters and the role of the neuromodulator calcium (Ca2+). METHODS Subretinal stim was applied on retinal explants (blind rd1 mouse) using multielectrode arrays (MEAs) or single metal electrodes, and the GC activity was recorded using Ca2+ imaging or MEA, respectively. Stim parameters, including voltage, phase polarity, and frequency, were investigated using specific blockers. RESULTS At lower stim frequencies (<5 Hz), GCs responded synaptically according to the stim pulses (stim: biphasic, cathodic-first, -1.6/+1.5 V). In contrast, higher stim frequencies (≥5 Hz) also activated GCs directly and induced a rapid GC spike response outage (<500 ms, MEA recordings), while in Ca2+ imaging at the same frequencies, increased intracellular Ca2+ levels were observed. CONCLUSIONS Our study elucidated the mechanisms involved in stim-dependent GC spike response outage: sustained high-frequency stim-induced spike outage, accompanied by electrogenically clamped intracellular Ca2+ levels at elevated levels. These findings will guide future studies optimizing stim paradigms for electrical implant applications for interfacing neurons.
Collapse
Affiliation(s)
| | | | - Wadood Haq
- Neuroretinal Electrophysiology and Imaging, Institute for Ophthalmic Research, Eberhard-Karls-Universität Tübingen, 72076 Tübingen, Germany; (L.P.)
| |
Collapse
|
5
|
Haq W, Basavaraju S, Speck A, Zrenner E. Nature-inspired saccadic-like electrical stimulation paradigm promotes sustained retinal ganglion cell responses by spatiotemporally alternating activation of contiguous multi-electrode patterns. J Neural Eng 2022; 19. [PMID: 36066085 DOI: 10.1088/1741-2552/ac8ad0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 08/18/2022] [Indexed: 11/12/2022]
Abstract
Objective. Retinal electrical stimulation using multi-electrode arrays (MEAs) aims to restore visual object perception in blind patients. However, the rate and duration of the artificial visual sensations are limited due to the rapid response decay of the stimulated neurons. Hence, we investigated a novel nature-inspired saccadic-like stimulation paradigm (biomimetic) to evoke sustained retinal responses. For implementation, the macroelectrode was replaced by several contiguous microelectrodes and activated non-simultaneously but alternating topologically.Approach.MEAs with hexagonally arranged electrodes were utilized to simulate and record mouse retinal ganglion cells (RGCs). Two shapes were presented electrically using MEAs: a 6e-hexagon (six hexagonally arranged 10µm electrodes; 6e-hexagon diameter: 80µm) and a double-bar (180µm spaced, 320µm in length). Electrodes of each shape were activated in three different modes (simultaneous, circular, and biomimetic ('zig-zag')), stimulating at different frequencies (1-20 Hz).Main results.The biomimetic stimulation generated enhanced RGC responses increasing the activity rate by 87.78%. In the spatiotemporal context, the electrical representation of the 6e-hexagon produced sustained and local RGC responses (∼130µm corresponding to ∼2.5° of the human visual angle) for up to 90 s at 10 Hz stimulation and resolved the electrically presented double-bar. In contrast, during conventional simultaneous stimulation, the responses were poor and declined within seconds. Similarly, the applicability of the biomimetic mode for retinal implants (7 × 8 pixels) was successfully demonstrated. An object shape impersonating a smile was presented electrically, and the recorded data were used to emulate the implant's performance. The spatiotemporal pixel mapping of the activity produced a complete retinal image of the smile.Significance.The application of electrical stimulation in the biomimetic mode produced locally enhanced RGC responses with significantly reduced fading effects and yielded advanced spatiotemporal performance reflecting the presented electrode shapes in the mapped activity imprint. Therefore, it is likely that the RGC responses persist long enough to evoke visual perception and generate a seamless image, taking advantage of the flicker fusion. Hence, replacing the implant's macroelectrodes with microelectrodes and their activation in a topologically alternating biomimetic fashion may overcome the patient's perceptual image fading, thereby enhancing the spatiotemporal characteristics of artificial vision.
Collapse
Affiliation(s)
- Wadood Haq
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| | - Sunetra Basavaraju
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| | - Achim Speck
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| | - Eberhart Zrenner
- Neuroretinal Electrophysiology and Imaging, Centre for Ophthalmology, Institute for Ophthalmic Research, University of Tübingen, Elfriede-Aulhorn-Str. 5-7, D-72076 Tübingen, Germany
| |
Collapse
|
6
|
Roh H, Otgondemberel Y, Im M. Short pulses of epiretinal prostheses evoke network-mediated responses in retinal ganglion cells by stimulating presynaptic neurons. J Neural Eng 2022; 19. [PMID: 36055185 DOI: 10.1088/1741-2552/ac8ed7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 09/02/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Microelectronic retinal implant aims to restore functional vision with electric stimulation. Short pulses are generally known to directly activate retinal ganglion cells (RGCs) with a notion of one or two spike(s) per pulse. In the present work, we systematically explore network-mediated responses that arise from various short pulses in both normal and degenerate retinas. APPROACH Cell-attached patch clamping was used to record spiking responses of RGCs in wild-type (C57BL/6J) and retinal degeneration (rd10) mice. Alpha RGCs of the mouse retinas were targeted by their large soma sizes and classified by their responses to spot flashes. Then, RGCs were electrically stimulated by various conditions such as duration (100-460 μs), count (1-10), amplitude (100-400 μA), and repeating frequency (10-40 Hz) of short pulses. Also, their responses were compared with each own response to a single 4-ms-long pulse which is known to evoke strong indirect responses. MAIN RESULTS Short pulses evoked strong network-mediated responses not only in both ON and OFF types of RGCs in the healthy retinas but also in RGCs of the severely degenerate retina. However, the spike timing consistency across repeats not decreased significantly in the rd10 RGCs compared to the healthy ON and OFF RGCs. Network-mediated responses of ON RGCs were highly dependent on the current amplitude of stimuli but much less on the pulse count and the repetition frequency. In contrast, responses of OFF RGCs were more influenced by the number of stimuli than the current amplitude. SIGNIFICANCE Our results demonstrate that short pulses also elicit indirect responses by activating presynaptic neurons. In the case of the commercial retinal prostheses using repeating short pulses, there is a possibility that the performance of clinical devices is highly related to the preserved retinal circuits. Therefore, examination of surviving retinal neurons in patients would be necessary to improve the efficacy of retinal prostheses.
Collapse
Affiliation(s)
- Hyeonhee Roh
- Korea Institute of Science and Technology (KIST), 5 Hwarang-ro 14-gil, Seongbuk-gu, Seoul, 02792, Korea (the Republic of)
| | - Yanjinsuren Otgondemberel
- Brain Science Institute, Korea Institute of Science and Technology (KIST), 5 Hwarang-ro 14-gil, Seongbuk-gu, Seoul, 02792, Korea (the Republic of)
| | - Maesoon Im
- Brain Science Institute, Center for BioMicrosystems, Korea Institute of Science and Technology, 5 Hwarang-ro 14-gil, Seongbuk-gu, L7325B, Seoul, Seoul, Seoul, 02792, Korea (the Republic of)
| |
Collapse
|
7
|
Li W, Haji Ghaffari D, Misra R, Weiland JD. Retinal ganglion cell desensitization is mitigated by varying parameter constant excitation pulse trains. Front Cell Neurosci 2022; 16:897146. [PMID: 36035262 PMCID: PMC9407683 DOI: 10.3389/fncel.2022.897146] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 07/15/2022] [Indexed: 11/20/2022] Open
Abstract
Retinal prostheses partially restore vision in patients blinded by retinitis pigmentosa (RP) and age-related macular degeneration (AMD). One issue that limits the effectiveness of retinal stimulation is the desensitization of the retina response to repeated pulses. Rapid fading of percepts is reported in clinical studies. We studied the retinal output evoked by fixed pulse trains vs. pulse trains that have variable parameters pulse-to-pulse. We used the current clamp to record RGC spiking in the isolated mouse retina. Trains of biphasic current pulses at different frequencies and amplitudes were applied. The main results we report are: (1) RGC desensitization was induced by increasing stimulus frequency, but was unrelated to stimulus amplitude. Desensitization persisted when the 20 Hz stimulation pulses were applied to the retinal ganglion cells at 65 μA, 85 μA, and 105 μA. Subsequent pulses in the train evoked fewer spikes. There was no obvious desensitization when 2 Hz stimulation pulse trains were applied. (2) Blocking inhibitory GABAA receptor increased spontaneous activity but did not reduce desensitization. (3) Pulse trains with constant charge or excitation (based on strength-duration curves) but varying pulse width, amplitude, and shape increased the number of evoked spikes/pulse throughout the pulse train. This suggests that retinal desensitization can be partially overcome by introducing variability into each pulse.
Collapse
Affiliation(s)
- Wennan Li
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
| | - Dorsa Haji Ghaffari
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
| | - Rohit Misra
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
| | - James D. Weiland
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, MI, United States
- Biointerfaces Institute, University of Michigan, Ann Arbor, MI, United States
- *Correspondence: James D. Weiland
| |
Collapse
|
8
|
Thorn JT, Chenais NAL, Hinrichs S, Chatelain M, Ghezzi D. Virtual reality validation of naturalistic modulation strategies to counteract fading in retinal stimulation. J Neural Eng 2022; 19. [PMID: 35240583 DOI: 10.1088/1741-2552/ac5a5c] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 03/03/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Temporal resolution is a key challenge in artificial vision. Several prosthetic approaches are limited by the perceptual fading of evoked phosphenes upon repeated stimulation from the same electrode. Therefore, implanted patients are forced to perform active scanning, via head movements, to refresh the visual field viewed by the camera. However, active scanning is a draining task, and it is crucial to find compensatory strategies to reduce it. APPROACH To address this question, we implemented perceptual fading in simulated prosthetic vision using virtual reality. Then, we quantified the effect of fading on two indicators: the time to complete a reading task and the head rotation during the task. We also tested if stimulation strategies previously proposed to increase the persistence of responses in retinal ganglion cells to electrical stimulation could improve these indicators. MAIN RESULTS This study shows that stimulation strategies based on interrupted pulse trains and randomisation of the pulse duration allows significant reduction of both the time to complete the task and the head rotation during the task. SIGNIFICANCE The stimulation strategy used in retinal implants is crucial to counteract perceptual fading and to reduce active head scanning during prosthetic vision. In turn, less active scanning might improve the patient's comfort in artificial vision.
Collapse
Affiliation(s)
- Jacob Thomas Thorn
- Neuroengineering, EPFL STI, Chemin des Mines 9, Geneva, 1202, SWITZERLAND
| | | | - Sandrine Hinrichs
- École Polytechnique Fédérale de Lausanne, Chemin des Mines 9, Geneva, 1202, SWITZERLAND
| | - Marion Chatelain
- École Polytechnique Fédérale de Lausanne, Chemin des Mines 9, Geneva, 1202, SWITZERLAND
| | - Diego Ghezzi
- Medtronic Chair in Neuroengineering, Ecole Polytechnique Federale de Lausanne, EPFL STI IBI LNE, Lausanne, 1015, SWITZERLAND
| |
Collapse
|
9
|
Paknahad J, Humayun M, Lazzi G. Selective Activation of Retinal Ganglion Cell Subtypes Through Targeted Electrical Stimulation Parameters. IEEE Trans Neural Syst Rehabil Eng 2022; 30:350-359. [PMID: 35130164 PMCID: PMC8904155 DOI: 10.1109/tnsre.2022.3149967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
To restore vision to the low vision, epiretinal implants have been developed to electrically stimulate the healthy retinal ganglion cells (RGCs) in the degenerate retina. Given the diversity of retinal ganglion cells as well as the difference in their visual function, selective activation of RGCs subtypes can significantly improve the quality of the restored vision. Our recent results demonstrated that with the proper modulation of the current amplitude, small D1-bistratified cells with the contribution to blue/yellow color opponent pathway can be selectively activated at high frequency (200 Hz). The computational results correlated with the clinical findings revealing the blue sensation of 5/7 subjects with epiretinal implants at high frequency. Here we further explored the impacts of alterations in pulse duration and interphase gap on the response of RGCs at high frequency. We used the developed RGCs, A2-monostratified and D1-bistratified, and examined their response to a range of pulse durations (0.1−1.2 ms) and interphase gaps (0−1 ms). We found that the use of short pulse durations with no interphase gap at high frequency increases the differential response of RGCs, offering better opportunities for selective activation of D1 cells. The presence of the interphase gap has shown to reduce the overall differential response of RGCs. We also explored how the low density of calcium channels enhances the responsiveness of RGCs at high frequency.
Collapse
|
10
|
Avraham D, Jung JH, Yitzhaky Y, Peli E. Retinal prosthetic vision simulation: temporal aspects. J Neural Eng 2021; 18. [PMID: 34359062 DOI: 10.1088/1741-2552/ac1b6c] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 08/06/2021] [Indexed: 11/11/2022]
Abstract
Objective. The perception of individuals fitted with retinal prostheses is not fully understood, although several retinal implants have been tested and commercialized. Realistic simulations of perception with retinal implants would be useful for future development and evaluation of such systems.Approach.We implemented a retinal prosthetic vision simulation, including temporal features, which have not been previously simulated. In particular, the simulation included temporal aspects such as persistence and perceptual fading of phosphenes and the electrode activation rate.Main results.The simulated phosphene persistence showed an effective reduction in flickering at low electrode activation rates. Although persistence has a positive effect on static scenes, it smears dynamic scenes. Perceptual fading following continuous stimulation affects prosthetic vision of both static and dynamic scenes by making them disappear completely or partially. However, we showed that perceptual fading of a static stimulus might be countered by head-scanning motions, which together with the persistence revealed the contours of the faded object. We also showed that changing the image polarity may improve simulated prosthetic vision in the presence of persistence and perceptual fading.Significance.Temporal aspects have important roles in prosthetic vision, as illustrated by the simulations. Considering these aspects may improve the future design, the training with, and evaluation of retinal prostheses.
Collapse
Affiliation(s)
- David Avraham
- Department of Electro-Optical Engineering, School of Electrical and Computer Engineering, Ben-Gurion University of the Negev, Beer Sheva, Israel.,Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, United States of America
| | - Jae-Hyun Jung
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, United States of America
| | - Yitzhak Yitzhaky
- Department of Electro-Optical Engineering, School of Electrical and Computer Engineering, Ben-Gurion University of the Negev, Beer Sheva, Israel
| | - Eli Peli
- Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, United States of America
| |
Collapse
|
11
|
Corna A, Ramesh P, Jetter F, Lee MJ, Macke JH, Zeck G. Discrimination of simple objects decoded from the output of retinal ganglion cells upon sinusoidal electrical stimulation. J Neural Eng 2021; 18. [PMID: 34049288 DOI: 10.1088/1741-2552/ac0679] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Accepted: 05/28/2021] [Indexed: 11/12/2022]
Abstract
Objective. Most neuroprosthetic implants employ pulsatile square-wave electrical stimuli, which are significantly different from physiological inter-neuronal communication. In case of retinal neuroprosthetics, which use a certain type of pulsatile stimuli, reliable object and contrast discrimination by implanted blind patients remained challenging. Here we investigated to what extent simple objects can be discriminated from the output of retinal ganglion cells (RGCs) upon sinusoidal stimulation.Approach. Spatially confined objects were formed by different combinations of 1024 stimulating microelectrodes. The RGC activity in theex vivoretina of photoreceptor-degenerated mouse, of healthy mouse or of primate was recorded simultaneously using an interleaved recording microelectrode array implemented in a CMOS-based chip.Main results. We report that application of sinusoidal electrical stimuli (40 Hz) in epiretinal configuration instantaneously and reliably modulates the RGC activity in spatially confined areas at low stimulation threshold charge densities (40 nC mm-2). Classification of overlapping but spatially displaced objects (1° separation) was achieved by distinct spiking activity of selected RGCs. A classifier (regularized logistic regression) discriminated spatially displaced objects (size: 5.5° or 3.5°) with high accuracy (90% or 62%). Stimulation with low artificial contrast (10%) encoded by different stimulus amplitudes generated RGC activity, which was classified with an accuracy of 80% for large objects (5.5°).Significance. We conclude that time-continuous smooth-wave stimulation provides robust, localized neuronal activation in photoreceptor-degenerated retina, which may enable future artificial vision at high temporal, spatial and contrast resolution.
Collapse
Affiliation(s)
- Andrea Corna
- Neurophysics, NMI Natural and Medical Sciences Institute at the University Tübingen, Reutlingen, Germany.,Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany.,Graduate School of Neural Information Processing/International Max Planck Research School, Tübingen, Germany.,Biomedical Electronics and Systems, EMCE Institute, TU Wien, Wien, Austria
| | - Poornima Ramesh
- Computational Neuroengineering, Technical University München, München, Germany.,Machine Learning in Science, University of Tübingen, Tübingen, Germany
| | - Florian Jetter
- Neurophysics, NMI Natural and Medical Sciences Institute at the University Tübingen, Reutlingen, Germany.,Graduate School of Neural Information Processing/International Max Planck Research School, Tübingen, Germany
| | - Meng-Jung Lee
- Neurophysics, NMI Natural and Medical Sciences Institute at the University Tübingen, Reutlingen, Germany.,Graduate School of Neural Information Processing/International Max Planck Research School, Tübingen, Germany
| | - Jakob H Macke
- Computational Neuroengineering, Technical University München, München, Germany.,Machine Learning in Science, University of Tübingen, Tübingen, Germany.,MPI for Intelligent Systems, Tübingen, Germany
| | - Günther Zeck
- Neurophysics, NMI Natural and Medical Sciences Institute at the University Tübingen, Reutlingen, Germany.,Biomedical Electronics and Systems, EMCE Institute, TU Wien, Wien, Austria
| |
Collapse
|
12
|
Moleirinho S, Whalen AJ, Fried SI, Pezaris JS. The impact of synchronous versus asynchronous electrical stimulation in artificial vision. J Neural Eng 2021; 18. [PMID: 33900206 DOI: 10.1088/1741-2552/abecf1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Accepted: 03/09/2021] [Indexed: 11/12/2022]
Abstract
Visual prosthesis devices designed to restore sight to the blind have been under development in the laboratory for several decades. Clinical translation continues to be challenging, due in part to gaps in our understanding of critical parameters such as how phosphenes, the electrically-generated pixels of artificial vision, can be combined to form images. In this review we explore the effects that synchronous and asynchronous electrical stimulation across multiple electrodes have in evoking phosphenes. Understanding how electrical patterns influence phosphene generation to control object binding and perception of visual form is fundamental to creation of a clinically successful prosthesis.
Collapse
Affiliation(s)
- Susana Moleirinho
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America
| | - Andrew J Whalen
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America
| | - Shelley I Fried
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America.,Boston VA Healthcare System, Boston, MA, United States of America
| | - John S Pezaris
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America
| |
Collapse
|
13
|
Hadjinicolaou AE, Meffin H, Maturana MI, Cloherty SL, Ibbotson MR. Prosthetic vision: devices, patient outcomes and retinal research. Clin Exp Optom 2021; 98:395-410. [DOI: 10.1111/cxo.12342] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 07/06/2015] [Accepted: 08/04/2015] [Indexed: 12/11/2022] Open
Affiliation(s)
- Alex E Hadjinicolaou
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
| | - Hamish Meffin
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
| | - Matias I Maturana
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- Department of Electrical and Electronic Engineering, The University of Melbourne, Parkville, Victoria, Australia,
| | - Shaun L Cloherty
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
- Department of Electrical and Electronic Engineering, The University of Melbourne, Parkville, Victoria, Australia,
| | - Michael R Ibbotson
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
| |
Collapse
|
14
|
Paknahad J, Loizos K, Yue L, Humayun MS, Lazzi G. Color and cellular selectivity of retinal ganglion cell subtypes through frequency modulation of electrical stimulation. Sci Rep 2021; 11:5177. [PMID: 33664347 PMCID: PMC7933163 DOI: 10.1038/s41598-021-84437-w] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 02/15/2021] [Indexed: 01/31/2023] Open
Abstract
Epiretinal prostheses aim at electrically stimulating the inner most surviving retinal cells-retinal ganglion cells (RGCs)-to restore partial sight to the blind. Recent tests in patients with epiretinal implants have revealed that electrical stimulation of the retina results in the percept of color of the elicited phosphenes, which depends on the frequency of stimulation. This paper presents computational results that are predictive of this finding and further support our understanding of the mechanisms of color encoding in electrical stimulation of retina, which could prove pivotal for the design of advanced retinal prosthetics that elicit both percept and color. This provides, for the first time, a directly applicable "amplitude-frequency" stimulation strategy to "encode color" in future retinal prosthetics through a predictive computational tool to selectively target small bistratified cells, which have been shown to contribute to "blue-yellow" color opponency in the retinal circuitry. The presented results are validated with experimental data reported in the literature and correlated with findings in blind patients with a retinal prosthetic implant collected by our group.
Collapse
Affiliation(s)
- Javad Paknahad
- grid.42505.360000 0001 2156 6853Department of Electrical Engineering, University of Southern California, Los Angeles, CA USA ,grid.42505.360000 0001 2156 6853The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA USA
| | - Kyle Loizos
- grid.42505.360000 0001 2156 6853The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA USA
| | - Lan Yue
- grid.42505.360000 0001 2156 6853Roski Eye Institute, University of Southern California, Los Angeles, CA USA
| | - Mark S. Humayun
- grid.42505.360000 0001 2156 6853Roski Eye Institute, University of Southern California, Los Angeles, CA USA ,grid.42505.360000 0001 2156 6853Departments of Ophthalmology and Biomedical Engineering, University of Southern California, Los Angeles, CA USA
| | - Gianluca Lazzi
- grid.42505.360000 0001 2156 6853Department of Electrical Engineering, University of Southern California, Los Angeles, CA USA ,grid.42505.360000 0001 2156 6853The Institute for Technology and Medical Systems (ITEMS), Keck School of Medicine, University of Southern California, Los Angeles, CA USA ,grid.42505.360000 0001 2156 6853Departments of Ophthalmology and Biomedical Engineering, University of Southern California, Los Angeles, CA USA
| |
Collapse
|
15
|
Chenais NAL, Airaghi Leccardi MJI, Ghezzi D. Naturalistic spatiotemporal modulation of epiretinal stimulation increases the response persistence of retinal ganglion cell. J Neural Eng 2021; 18. [DOI: 10.1088/1741-2552/abcd6f] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Accepted: 11/24/2020] [Indexed: 12/24/2022]
|
16
|
Restoring Color Perception to the Blind: An Electrical Stimulation Strategy of Retina in Patients with End-stage Retinitis Pigmentosa. Ophthalmology 2020; 128:453-462. [PMID: 32858064 DOI: 10.1016/j.ophtha.2020.08.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 08/05/2020] [Accepted: 08/10/2020] [Indexed: 11/24/2022] Open
Abstract
PURPOSE Bioelectronic retinal prostheses that stimulate the remaining inner retinal neurons, bypassing degenerated photoreceptors, have been demonstrated to restore some vision in patients blinded by retinitis pigmentosa (RP). These implants encode luminance of the visual scene into electrical stimulation, however, leaving out chromatic information. Yet color plays an important role in visual processing when it comes to recognizing objects and orienting to the environment, especially at low spatial resolution as generated by current retinal prostheses. In this study, we tested the feasibility of partially restoring color perception in blind RP patients, with the aim to provide chromatic information as an extra visual cue. DESIGN Case series. PARTICIPANTS Seven subjects blinded by advanced RP and monocularly fitted with an epiretinal prosthesis. METHODS Frequency-modulated electrical stimulation of retina was tested. Phosphene brightness was controlled by amplitude tuning, and color perception was acquired using the Red, Yellow, Green, and Blue (RYGB) hue and saturation scaling model. MAIN OUTCOME MEASURES Brightness and color of the electrically elicited visual perception reported by the subjects. RESULTS Within the tested parameter space, 5 of 7 subjects perceived chromatic colors along or nearby the blue-yellow axis in color space. Aggregate data obtained from 20 electrodes of the 5 subjects show that an increase of the stimulation frequency from 6 to 120 Hz shifted color perception toward blue/purple despite a significant inter-subject variation in the transition frequency. The correlation between frequency and blue-yellow perception exhibited a good level of consistency over time and spatially matched multi-color perception was possible with simultaneous stimulation of paired electrodes. No obvious correlation was found between blue sensations and array placement or status of visual impairment. CONCLUSIONS These findings present a strategy for the generation and control of color perception along the blue-yellow axis in blind patients with RP by electrically stimulating the retina. It could transform the current prosthetic vision landscape by leading in a new direction beyond the efforts to improve the visual acuity. This study also offers new insights into the response of our visual system to electrical stimuli in the photoreceptor-less retina that warrant further mechanistic investigation.
Collapse
|
17
|
Shivdasani MN, Evans M, Burns O, Yeoh J, Allen PJ, Nayagam DAX, Villalobos J, Abbott CJ, Luu CD, Opie NL, Sabu A, Saunders AL, McPhedran M, Cardamone L, McGowan C, Maxim V, Williams RA, Fox KE, Cicione R, Garrett DJ, Ahnood A, Ganesan K, Meffin H, Burkitt AN, Prawer S, Williams CE, Shepherd RK. In vivo feasibility of epiretinal stimulation using ultrananocrystalline diamond electrodes. J Neural Eng 2020; 17:045014. [PMID: 32659750 DOI: 10.1088/1741-2552/aba560] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVE Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. APPROACH A prototype implant containing up to twenty-five 120 × 120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. MAIN RESULTS The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in eight animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. SIGNIFICANCE The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.
Collapse
Affiliation(s)
- Mohit N Shivdasani
- Graduate School of Biomedical Engineering, University of New South Wales, Kensington, NSW 2033, Australia. The Bionics Institute of Australia, East Melbourne, VIC 3002, Australia
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Muralidharan M, Guo T, Shivdasani MN, Tsai D, Fried S, Li L, Dokos S, Morley JW, Lovell NH. Neural activity of functionally different retinal ganglion cells can be robustly modulated by high-rate electrical pulse trains. J Neural Eng 2020; 17:045013. [DOI: 10.1088/1741-2552/ab9a97] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
19
|
Höfling L, Oesterle J, Berens P, Zeck G. Probing and predicting ganglion cell responses to smooth electrical stimulation in healthy and blind mouse retina. Sci Rep 2020; 10:5248. [PMID: 32251331 PMCID: PMC7090015 DOI: 10.1038/s41598-020-61899-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 02/19/2020] [Indexed: 11/14/2022] Open
Abstract
Retinal implants are used to replace lost photoreceptors in blind patients suffering from retinopathies such as retinitis pigmentosa. Patients wearing implants regain some rudimentary visual function. However, it is severely limited compared to normal vision because non-physiological stimulation strategies fail to selectively activate different retinal pathways at sufficient spatial and temporal resolution. The development of improved stimulation strategies is rendered difficult by the large space of potential stimuli. Here we systematically explore a subspace of potential stimuli by electrically stimulating healthy and blind mouse retina in epiretinal configuration using smooth Gaussian white noise delivered by a high-density CMOS-based microelectrode array. We identify linear filters of retinal ganglion cells (RGCs) by fitting a linear-nonlinear-Poisson (LNP) model. Our stimulus evokes spatially and temporally confined spiking responses in RGC which are accurately predicted by the LNP model. Furthermore, we find diverse shapes of linear filters in the linear stage of the model, suggesting diverse preferred electrical stimuli of RGCs. The linear filter base identified by our approach could provide a starting point of a model-guided search for improved stimuli for retinal prosthetics.
Collapse
Affiliation(s)
- Larissa Höfling
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany
- Graduate Training Centre of Neuroscience, University of Tübingen, Tübingen, Germany
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Centre for Integrative Neuroscience, University of Tübingen, Tübingen, Germany
| | - Jonathan Oesterle
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
| | - Philipp Berens
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Bernstein Center for Computational Neuroscience, University of Tübingen, Tübingen, Germany
- Department of Computer Science, University of Tübingen, Tübingen, Germany
| | - Günther Zeck
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany.
- Bernstein Center for Computational Neuroscience, University of Tübingen, Tübingen, Germany.
| |
Collapse
|
20
|
Spatiotemporal integration of visual stimuli and its relevance to the use of a divisional power supply scheme for retinal prosthesis. PLoS One 2020; 15:e0228861. [PMID: 32084146 PMCID: PMC7034871 DOI: 10.1371/journal.pone.0228861] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2019] [Accepted: 01/25/2020] [Indexed: 11/19/2022] Open
Abstract
A wireless photovoltaic retinal prosthesis is currently being studied with the aim of providing prosthetic vision to patients with retinitis pigmentosa (RP) and age-related macular degeneration (AMD). The major challenge of a photovoltaic device is its limited power efficiency. Our retinal prosthetic design implements a unique divisional power supply scheme (DPSS) system that provides the electrical power generated by all of the solar cells to only a subset of electrodes at any moment in time. The aim of the present study was to systematically characterize the spatiotemporal integration performance of the system under various DPSS conditions using human subjects and a psychophysical approach. A 16x16 pixels LED array controlled by Arduino was used to simulate the output signal of the DPSS design, and human performance under different visual stimulations at various update frequencies was then used to assess the spatiotemporal capability of retinal prostheses. The results showed that the contrast polarity of the image, image brightness, and division number influenced the lower limit of the update frequency of the DPSS system, while, on the other hand, visual angle, ambient light level, and stimulation order did not affect performance significantly. Pattern recognition by visual persistence with spatiotemporal integration of multiple frames of sparse dots is a feasible approach in retinal prosthesis design. These findings provide an insight into how to optimize a photovoltaic retinal prosthesis using a DPSS design with an appropriate update frequency for reliable pattern recognition. This will help the development of a wireless device able to restore vision to RP and AMD patients in the future.
Collapse
|
21
|
Zehra S, Damien Hicks G, Adjinicolaou A, Michael Ibbotson R, Kameneva T. Differences between morphological and electrophysiological retinal ganglion cell classes. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2018:3056-3059. [PMID: 30441743 DOI: 10.1109/embc.2018.8512899] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Retinal prostheses work by delivering electrical pulses to the surviving retinal neurons. A pattern of electrical stimulation can generate a perception of vision in blind patients. To improve efficacy of retinal implants, it is important to understand how different classes of retinal neurons respond to electrical stimulation and if a classification can be made based on the electrophysiological properties of neurons. We use previously recorded patch clamp data from retinal ganglion cells classified into morphological classes (A,B,C, D) and functional types (ON, OFF, ON-OFF). We use a machine learning technique to separate data based on the recorded electrophysiological parameters. Results show that the clusters discovered using the machine learning technique do not correspond to the morphological or functional classes used by neuroscientists.
Collapse
|
22
|
Ryu SB, Werginz P, Fried SI. Response of Mouse Visual Cortical Neurons to Electric Stimulation of the Retina. Front Neurosci 2019; 13:324. [PMID: 31019449 PMCID: PMC6459047 DOI: 10.3389/fnins.2019.00324] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Accepted: 03/21/2019] [Indexed: 12/27/2022] Open
Abstract
Retinal prostheses strive to restore vision to the blind by electrically stimulating the neurons that survive the disease process. Clinical effectiveness has been limited however, and much ongoing effort is devoted toward the development of improved stimulation strategies, especially ones that better replicate physiological patterns of neural signaling. Here, to better understand the potential effectiveness of different stimulation strategies, we explore the responses of neurons in the primary visual cortex to electric stimulation of the retina. A 16-channel implantable microprobe was used to record single unit activities in vivo from each layer of the mouse visual cortex. Layers were identified by electrode depth as well as spontaneous rate. Cell types were classified as excitatory or inhibitory based on their spike waveform and as ON, OFF, or ON-OFF based on the polarity of their light response. After classification, electric stimulation was delivered via a wire electrode placed on the surface of cornea (extraocularly) and responses were recorded from the cortex contralateral to the stimulated eye. Responses to electric stimulation were highly similar across cell types and layers. Responses (spike counts) increased as a function of the amplitude of stimulation, and although there was some variance across cells, the sensitivity to amplitude was largely similar across all cell types. Suppression of responses was observed for pulse rates ≥3 pulses per second (PPS) but did not originate in the retina as RGC responses remained stable to rates up to 5 PPS. Low-frequency sinusoids delivered to the retina replicated the out-of-phase responses that occur naturally in ON vs. OFF RGCs. Intriguingly, out-of-phase signaling persisted in V1 neurons, suggesting key aspects of neural signaling are preserved during transmission along visual pathways. Our results describe an approach to evaluate responses of cortical neurons to electric stimulation of the retina. By examining the responses of single cells, we were able to show that some retinal stimulation strategies can indeed better match the neural signaling patterns used by the healthy visual system. Because cortical signaling is better correlated to psychophysical percepts, the ability to evaluate which strategies produce physiological-like cortical responses may help to facilitate better clinical outcomes.
Collapse
Affiliation(s)
- Sang Baek Ryu
- Boston VA Healthcare System, Boston, MA, United States.,Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| | - Paul Werginz
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States.,Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria
| | - Shelley I Fried
- Boston VA Healthcare System, Boston, MA, United States.,Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
| |
Collapse
|
23
|
Chang YC, Haji Ghaffari D, Chow RH, Weiland JD. Stimulation strategies for selective activation of retinal ganglion cell soma and threshold reduction. J Neural Eng 2019; 16:026017. [PMID: 30560810 PMCID: PMC6648650 DOI: 10.1088/1741-2552/aaf92b] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
OBJECTIVE Retinal prosthetic implants restore partial vision to patients blinded due to outer retinal degeneration, using a camera-guided multielectrode array (MEA) that electrically stimulates surviving retinal neurons. Commercial epi-retinal prostheses use millisecond-scale charge-balanced, symmetric, cathodic-first biphasic pulses to depolarize retinal ganglion cells (RGCs) and bipolar cells (BCs), frequently creating oblong perceptions of light related to axonal activation of RGCs. Stimulation strategies that avoid axonal stimulation and decrease the threshold of targeted neurons may significantly improve prosthetic vision in terms of spatial resolution and power efficiency. APPROACH We developed a virus-transduced genetically encoded calcium indicator (GECI) GCaMP6f and microscopy platform for calcium imaging to record the neural activity from RGCs at single-cell resolution in wholemount retinas. Multiple stimulation paradigms were applied through a microelectrode array (MEA) with transparent indium tin oxide electrodes. The evoked neuronal activities were converted to corresponding 2D calcium imaging transient pattern and spatial threshold map to identify the ideal focal response which corresponds to optimal percept in patient. MAIN RESULTS The proposed optical system with GCaMP6f is capable of recording from population of mouse RGCs in real time during electrical stimulation with precise location information relative to the stimulation sites. Optimal duration and phase order of pulse were identified to avoid axonal stimulation and selectively activate targeted RGC somas, without requiring a significant increase in stimulation charge. Additionally, we show that reduced stimulus threshold can be achieved with the special design of asymmetric anodic-first pulse. SIGNIFICANCE Our findings support the possibility of manipulating the responses of RGCs through varying the stimulation waveform. Focal response can be achieved with relative short duration (⩽120 μs) pulses, and can be improved by reversing the standard phase order. The RGCs threshold can be significantly reduced by 33.3%-50% in terms of charge through applying hyperpolarizing pre-pulses with a 20:1 ratio (pre-pulse:stimulus pulse). The results support the future retinal prosthesis design that potentially forms more ideal shape perception with higher spatial resolution and power efficiency.
Collapse
Affiliation(s)
- Yao-Chuan Chang
- Center for Bioelectronic Medicine & Biomedical Science, Feinstein Institute for Medical Research, Manhasset, NY 11030, United States of America
| | | | | | | |
Collapse
|
24
|
Rathbun DL, Ghorbani N, Shabani H, Zrenner E, Hosseinzadeh Z. Spike-triggered average electrical stimuli as input filters for bionic vision—a perspective. J Neural Eng 2018; 15:063002. [DOI: 10.1088/1741-2552/aae493] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
25
|
Soto-Breceda A, Kameneva T, Meffin H, Maturana M, Ibbotson MR. Irregularly timed electrical pulses reduce adaptation of retinal ganglion cells. J Neural Eng 2018; 15:056017. [PMID: 30021932 DOI: 10.1088/1741-2552/aad46e] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVE Retinal prostheses aim to provide visual percepts to blind people affected by diseases caused by photoreceptor degeneration. One of the main challenges presented by current devices is neural adaptation in the retina, which is believed to be the cause of fading-an effect where artificially produced percepts disappear over a short period of time, despite continuous stimulation of the retina. We aim to understand the neural adaptation generated in retinal ganglion cells (RGCs) during electrical stimulation. APPROACH Current visual prostheses use electrical pulses with fixed frequencies and amplitudes modulated over hundreds of milliseconds to stimulate the retina. However, in nature, neuronal spiking occurs with stochastic timing, hence the information received naturally from other neurons by RGCs is irregularly timed. We used a single epiretinal electrode to stimulate and compare rat RGC responses to stimulus trains of biphasic pulses delivered at regular and random inter-pulse intervals (IPI), the latter taken from an exponential distribution. MAIN RESULTS Our observations suggest that stimulation with random IPIs result in lower adaptation rates than stimulation with constant IPIs at frequencies of 50 Hz and 200 Hz. We also found a high proportion of lower amplitude action potentials, or spikelets. The spikelets were more prominent at high stimulation frequencies (50 Hz and 200 Hz) and were less susceptible to adaptation, but it was not clear if they propagated along the axon. SIGNIFICANCE Using random IPI stimulation in retinal prostheses reduces the decay of RGCs and this could potentially reduce fading of electrically induced visual perception.
Collapse
Affiliation(s)
- A Soto-Breceda
- National Vision Research Institute, Australian College of Optometry, Melbourne, Australia. Department of Biomedical Engineering, The University of Melbourne, Melbourne, Australia. CSIRO, Data 61, Melbourne, Australia
| | | | | | | | | |
Collapse
|
26
|
Lee JI, Im M. Non-rectangular waveforms are more charge-efficient than rectangular one in eliciting network-mediated responses of ON type retinal ganglion cells. J Neural Eng 2018; 15:055004. [PMID: 30018183 DOI: 10.1088/1741-2552/aad416] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE For individuals blinded by outer retinal degenerative diseases, retinal prostheses would be a promising option to restore sight. Unfortunately, however, the best performance of existing devices is still far removed from normal vision. One possible reason for the shortcoming is thought to be suboptimal stimulation conditions such as the waveform shape of electric stimulus. In this study, we explored the effects of varying waveforms on network-mediated responses arising in retinal ganglion cells (RGCs). APPROACH We used a cell-attached patch clamp technique to record RGC spiking activities in the isolated mouse retina. ON alpha RGCs were targeted by soma size and their light responses to stationary spot flashes. Spiking in targeted RGCs was measured in response to an epiretinally-delivered cathodal current pulse in four waveforms: rectangular, center triangular, increasing and decreasing ramp shapes. Each waveform was tested at three durations (20, 10, and 5 ms) with adjusted amplitude for a range of total charges (50-400 nC). MAIN RESULTS ON alpha RGCs always generated two bursts of spikes in responses to all stimuli conditions we tested. However, at a given charge, effects of differing waveforms were distinct in the two bursts. For the first burst, the increasing ramp was most effective among the four waveforms (p < 0.05 for all pairwise comparisons with other waveforms). For example, in responses arising from 20 ms-long stimuli, the increasing ramp evoked ~44% more spikes on average than the rectangular shape which is the typical choice of neural stimulation. Also, the rectangular stimulus evoked the weakest response in the delayed burst arising from pulses of every duration. For instance, 20 ms-long stimuli in the three non-rectangular waveforms showed ~23% or more increment in spike counts compared to response arising from the rectangular one; but there was no statistical difference in response magnitudes across the non-rectangular waveforms. SIGNIFICANCE Although the rectangular waveform has been primarily used in retinal prostheses our results indicate that rectangular stimulus is not optimal for network-mediated responses of ON alpha RGCs. Instead, non-rectangular waveforms evoke stronger responses at a given charge, indicating higher charge-efficiency. Therefore, non-rectangular waveforms are expected to enhance clinical efficacy of retinal prostheses.
Collapse
Affiliation(s)
- Jae-Ik Lee
- Department of Ophthalmology, Henry Ford Health System, 1 Ford Place, Detroit, MI 48202, United States of America. Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA 02114, United States of America
| | | |
Collapse
|
27
|
Yang CY, Tsai D, Guo T, Dokos S, Suaning GJ, Morley JW, Lovell NH. Differential electrical responses in retinal ganglion cell subtypes: effects of synaptic blockade and stimulating electrode location. J Neural Eng 2018; 15:046020. [PMID: 29737971 DOI: 10.1088/1741-2552/aac315] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Visual prostheses have shown promising results in restoring visual perception to blind patients. The ability to differentially activate retinal ganglion cell (RGC) subtypes could further improve the efficacy of these medical devices. APPROACH Using whole-cell patch clamp, we investigated membrane potential differences between ON and OFF RGCs in the mouse retina when their synaptic inputs were blocked by synaptic blockers, and examined the differences in stimulation thresholds under such conditions. By injecting intracellular current, we further confirmed the relationship between RGC stimulation thresholds and resting membrane potentials (RMPs). In addition, we investigated the effects of stimulating electrode location on the differences in stimulation thresholds between ON and OFF RGCs. MAIN RESULTS With synaptic blockade, ON RGCs became significantly more hyperpolarized (from -61.8 ± 1.4 mV to -70.8 ± 1.6 mV), while OFF RGCs depolarized slightly (from -60.5 ± 0.7 mV to -58.6 ± 0.9 mV). RGC stimulation thresholds were negatively correlated with their RMPs (Pearson r value: -0.5154; p-value: 0.0042). Thus, depriving ON RGCs of synaptic inputs significantly increased their thresholds (from 14.7 ± 1.3 µA to 22.3 ± 2.1 µA) over those of OFF RGCs (from 13.2 ± 0.7 µA to 13.1 ± 1.1 µA). However, with control solution, ON and OFF RGC stimulation thresholds were not significantly different. Finally, placement of the stimulating electrode away from the axon enhanced differences in stimulation thresholds between ON and OFF RGCs, facilitating preferential activation of OFF RGCs. SIGNIFICANCE Since ON and OFF RGCs have antagonistic responses to natural light, achieving differential RGC activation could convey more natural visual information, leading to better visual prosthesis outcomes.
Collapse
Affiliation(s)
- Chih Yu Yang
- Graduate School of Biomedical Engineering, UNSW, Sydney, NSW 2052, Australia
| | | | | | | | | | | | | |
Collapse
|
28
|
Meng K, Fellner A, Rattay F, Ghezzi D, Meffin H, Ibbotson MR, Kameneva T. Upper stimulation threshold for retinal ganglion cell activation. J Neural Eng 2018; 15:046012. [PMID: 29616983 DOI: 10.1088/1741-2552/aabb7d] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The existence of an upper threshold in electrically stimulated retinal ganglion cells (RGCs) is of interest because of its relevance to the development of visual prosthetic devices, which are designed to restore partial sight to blind patients. The upper threshold is defined as the stimulation level above which no action potentials (direct spikes) can be elicited in electrically stimulated retina. APPROACH We collected and analyzed in vitro recordings from rat RGCs in response to extracellular biphasic (anodic-cathodic) pulse stimulation of varying amplitudes and pulse durations. Such responses were also simulated using a multicompartment model. MAIN RESULTS We identified the individual cell variability in response to stimulation and the phenomenon known as upper threshold in all but one of the recorded cells (n = 20/21). We found that the latencies of spike responses relative to stimulus amplitude had a characteristic U-shape. In silico, we showed that the upper threshold phenomenon was observed only in the soma. For all tested biphasic pulse durations, electrode positions, and pulse amplitudes above lower threshold, a propagating action potential was observed in the distal axon. For amplitudes above the somatic upper threshold, the axonal action potential back-propagated in the direction of the soma, but the soma's low level of hyperpolarization prevented action potential generation in the soma itself. SIGNIFICANCE An upper threshold observed in the soma does not prevent spike conductance in the axon.
Collapse
Affiliation(s)
- Kevin Meng
- National Vision Research Institute, Australian College of Optometry, Australia. Department of Biomedical Engineering, The University of Melbourne, Australia
| | | | | | | | | | | | | |
Collapse
|
29
|
Walston ST, Chow RH, Weiland JD. Direct measurement of bipolar cell responses to electrical stimulation in wholemount mouse retina. J Neural Eng 2018. [PMID: 29513646 DOI: 10.1088/1741-2552/aab4ed] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE This in vitro investigation examines the response of retinal bipolar cells to extracellular electrical stimulation. APPROACH In vitro investigations characterizing the response of retinal neurons to electrical stimulation have primarily focused on retinal ganglion cells because they are the output neurons of the retina and their superficial position in the retina makes them readily accessible to in vitro recording techniques. Thus, the majority of information regarding the response of inner retinal neurons has been inferred from ganglion cell activity. Here we use patch clamp electrophysiology to directly record electrically-evoked activity in bipolar cells within the inner retina of normal Tg(Gng13-EGFP)GI206Gsat and degenerate rd10 Tg(Gng13-EGFP)GI206Gsat mice using a wholemount preparation. MAIN RESULTS Bipolar cells respond to electrical stimulation with time-locked depolarizing voltage transients. The latency of the response declines with increases in stimulation amplitude. A desensitizing response is observed during repeated stimulation with 25 ms biphasic current pulses delivered at pulse rates greater than 6 pps. A burst of long-latency (200-1000 ms) inhibitory postsynaptic potentials are evoked by the stimulus and the burst exhibits evidence of a lower and upper stimulation threshold. SIGNIFICANCE These results provide insights into the various types of bipolar cell activity elicited by electrical stimulation and may be useful for future retinal prosthesis stimulation protocols. This investigation uses patch clamp electrophysiology to provide direct analysis of ON-type bipolar cell responses to electrical stimulation in a wholemount retina preparation. It explores the effects of variable stimulus amplitudes, pulse widths, and frequencies in both normal and degenerate retina. The analysis adds to a body of work largely based upon indirect measurements of bipolar cell activity, and the methodology demonstrates an alternative retina preparation technique in which to acquire single-cell activity.
Collapse
Affiliation(s)
- Steven T Walston
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90007, United States of America
| | | | | |
Collapse
|
30
|
Electrical receptive fields of retinal ganglion cells: Influence of presynaptic neurons. PLoS Comput Biol 2018; 14:e1005997. [PMID: 29432411 PMCID: PMC5825175 DOI: 10.1371/journal.pcbi.1005997] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Revised: 02/23/2018] [Accepted: 01/24/2018] [Indexed: 11/26/2022] Open
Abstract
Implantable retinal stimulators activate surviving neurons to restore a sense of vision in people who have lost their photoreceptors through degenerative diseases. Complex spatial and temporal interactions occur in the retina during multi-electrode stimulation. Due to these complexities, most existing implants activate only a few electrodes at a time, limiting the repertoire of available stimulation patterns. Measuring the spatiotemporal interactions between electrodes and retinal cells, and incorporating them into a model may lead to improved stimulation algorithms that exploit the interactions. Here, we present a computational model that accurately predicts both the spatial and temporal nonlinear interactions of multi-electrode stimulation of rat retinal ganglion cells (RGCs). The model was verified using in vitro recordings of ON, OFF, and ON-OFF RGCs in response to subretinal multi-electrode stimulation with biphasic pulses at three stimulation frequencies (10, 20, 30 Hz). The model gives an estimate of each cell’s spatiotemporal electrical receptive fields (ERFs); i.e., the pattern of stimulation leading to excitation or suppression in the neuron. All cells had excitatory ERFs and many also had suppressive sub-regions of their ERFs. We show that the nonlinearities in observed responses arise largely from activation of presynaptic interneurons. When synaptic transmission was blocked, the number of sub-regions of the ERF was reduced, usually to a single excitatory ERF. This suggests that direct cell activation can be modeled accurately by a one-dimensional model with linear interactions between electrodes, whereas indirect stimulation due to summated presynaptic responses is nonlinear. Implantable neural stimulation devices are being widely used and clinically tested for the restoration of lost function (e.g. cochlear implants) and the treatment of neurological disorders. Smart devices that can combine sensing and stimulation will dramatically improve future patient outcomes. To this end, mathematical models that can accurately predict neural responses to electrical stimulation will be critical for the development of smart stimulation devices. Here, we demonstrate a model that predicts neural responses to simultaneous stimulation across multiple electrodes in the retina. We show that the activation of presynaptic neurons leads to nonlinearities in the responses of postsynaptic retinal ganglion cells. The model is accurate and is applicable to a wide range of neural stimulation devices.
Collapse
|
31
|
Weiland JD, Walston ST, Humayun MS. Electrical Stimulation of the Retina to Produce Artificial Vision. Annu Rev Vis Sci 2018; 2:273-294. [PMID: 28532361 DOI: 10.1146/annurev-vision-111815-114425] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Retinal prostheses aim to restore vision to blind individuals suffering from retinal diseases such as retinitis pigmentosa and age-related macular degeneration. These devices function by electrically stimulating surviving retinal neurons, whose activation is interpreted by the brain as a visual percept. Many prostheses are currently under development. They are categorized as epiretinal, subretinal, and suprachoroidal prostheses on the basis of the placement of the stimulating microelectrode array. Each can activate ganglion cells through direct or indirect stimulation. The response of retinal neurons to these modes of stimulation are discussed in detail and are placed in context of the visual percept they are likely to evoke. This article further reviews challenges faced by retinal prosthesis and discusses potential solutions to address them.
Collapse
Affiliation(s)
- James D Weiland
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90007; .,USC Roski Eye Institute, University of Southern California, Los Angeles, California 90033.,Institute for Biomedical Therapeutics, University of Southern California, Los Angeles, California 90033
| | - Steven T Walston
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90007;
| | - Mark S Humayun
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90007; .,USC Roski Eye Institute, University of Southern California, Los Angeles, California 90033.,Institute for Biomedical Therapeutics, University of Southern California, Los Angeles, California 90033
| |
Collapse
|
32
|
Molino PJ, Garcia L, Stewart EM, Lamaze M, Zhang B, Harris AR, Winberg P, Wallace GG. PEDOT doped with algal, mammalian and synthetic dopants: polymer properties, protein and cell interactions, and influence of electrical stimulation on neuronal cell differentiation. Biomater Sci 2018; 6:1250-1261. [DOI: 10.1039/c7bm01156c] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PEDOT films were electrochemically polymerised with synthetic and biological dopants, characterised, and their interactions with proteins and neuronal cells investigated.
Collapse
Affiliation(s)
- P. J. Molino
- ARC Centre of Excellence for Electromaterials Science (ACES)
- University of Wollongong
- Wollongong
- Australia
- ARC Research Hub for Australian Steel Manufacturing
| | - L. Garcia
- ARC Centre of Excellence for Electromaterials Science (ACES)
- University of Wollongong
- Wollongong
- Australia
| | - E. M. Stewart
- ARC Centre of Excellence for Electromaterials Science (ACES)
- University of Wollongong
- Wollongong
- Australia
| | - M. Lamaze
- ARC Centre of Excellence for Electromaterials Science (ACES)
- University of Wollongong
- Wollongong
- Australia
| | - B. Zhang
- ARC Centre of Excellence for Electromaterials Science (ACES)
- University of Wollongong
- Wollongong
- Australia
- HEARing CRC
| | - A. R. Harris
- ARC Centre of Excellence for Electromaterials Science (ACES)
- University of Wollongong
- Wollongong
- Australia
- HEARing CRC
| | - P. Winberg
- Venus Shell Systems Pty. Ltd
- Bomaderry
- Australia
- School of Medicine
- University of Wollongong
| | - G. G. Wallace
- ARC Centre of Excellence for Electromaterials Science (ACES)
- University of Wollongong
- Wollongong
- Australia
| |
Collapse
|
33
|
Sivanesan E, Levitt RC, Sarantopoulos CD, Patin D, Galor A. Noninvasive Electrical Stimulation for the Treatment of Chronic Ocular Pain and Photophobia. Neuromodulation 2017; 21:727-734. [PMID: 29283468 DOI: 10.1111/ner.12742] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2017] [Revised: 10/20/2017] [Accepted: 11/06/2017] [Indexed: 02/06/2023]
Abstract
INTRODUCTION "Dry eye" or "keratoconjunctivitis sicca" is a multifactorial disease estimated to have a worldwide prevalence of 5-33%. Conventional therapies targeting the ocular surface with artificial tears, anti-inflammatories, punctal closure, eyelid hygiene, and antibiotics do not provide relief in all patients, especially those with neuropathic-like ocular complaints (wind hyperalgesia and photophobia). We anticipated that ocular transcutaneous electrical nerve stimulation (TENS) would alleviate symptoms of ocular pain, photophobia, and dryness in these latter individuals. METHODS All individuals who received electrical stimulation between May 10, 2016 and April 6, 2017 for the treatment of chronic ocular pain at the oculofacial pain clinic of the Miami Veterans Administration Hospital were included in this retrospective review. All patients had symptoms of dryness along with other neuropathic-like symptoms (e.g., photophobia) and minimal signs of tear dysfunction. Ocular pain intensity, symptoms of dryness, and light sensitivity were compared pre-treatment and five min post-treatment via a two-tailed paired Student's t-test. RESULTS The use of TENS significantly reduced the mean pain intensity in both the right and left eyes five min after treatment compared to prior to treatment (p < 0.05, paired t-test). The use of TENS significantly decreased light sensitivity in both eyes (p < 0.05). The findings for symptoms of dryness, however, were equivocal with a significant decrease in the left eye but not the right (p < 0.05, paired t-test). DISCUSSION Our data indicate that TENS may similarly provide analgesia in patients with dry eye symptoms as it does for many other chronic pain conditions. Furthermore, the noted effect on symptoms of photophobia and dryness suggest that all may be linked by similar trigeminal-thalamic-cortical pathways. Prospective studies with electrical stimulation of dry eye are needed to further elucidate its benefit and mechanism of action.
Collapse
Affiliation(s)
- Eellan Sivanesan
- Miami Veterans Administration Medical Center, Miami, FL, USA.,Department of Anesthesiology, Perioperative Medicine and Pain Management, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Roy C Levitt
- Department of Anesthesiology, Perioperative Medicine and Pain Management, University of Miami, Miller School of Medicine, Miami, FL, USA.,Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA.,John P. Hussman Institute for Human Genomics, University of Miami, Miller School of Medicine, Miami, FL, USA.,Department of Human Genetics, John T. Macdonald Foundation, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Constantine D Sarantopoulos
- Department of Anesthesiology, Perioperative Medicine and Pain Management, University of Miami, Miller School of Medicine, Miami, FL, USA.,Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA
| | - Dennis Patin
- Department of Anesthesiology, Perioperative Medicine and Pain Management, University of Miami, Miller School of Medicine, Miami, FL, USA
| | - Anat Galor
- Miami Veterans Administration Medical Center, Miami, FL, USA.,Department of Anesthesiology, Perioperative Medicine and Pain Management, University of Miami, Miller School of Medicine, Miami, FL, USA.,Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA
| |
Collapse
|
34
|
Zhu W, Ye T, Lee SJ, Cui H, Miao S, Zhou X, Shuai D, Zhang LG. Enhanced neural stem cell functions in conductive annealed carbon nanofibrous scaffolds with electrical stimulation. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2017; 14:2485-2494. [PMID: 28552650 DOI: 10.1016/j.nano.2017.03.018] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Revised: 01/19/2017] [Accepted: 03/06/2017] [Indexed: 01/19/2023]
Abstract
Carbon-based nanomaterials have shown great promise in regenerative medicine because of their unique electrical, mechanical, and biological properties; however, it is still difficult to engineer 2D pure carbon nanomaterials into a 3D scaffold while maintaining its structural integrity. In the present study, we developed novel carbon nanofibrous scaffolds by annealing electrospun mats at elevated temperature. The resultant scaffold showed a cohesive structure and excellent mechanical flexibility. The graphitic structure generated by annealing renders superior electrical conductivity to the carbon nanofibrous scaffold. By integrating the conductive scaffold with biphasic electrical stimulation, neural stem cell proliferation was promoted associating with upregulated neuronal gene expression level and increased microtubule-associated protein 2 immunofluorescence, demonstrating an improved neuronal differentiation and maturation. The findings suggest that the integration of the conducting carbon nanofibrous scaffold and electrical stimulation may pave a new avenue for neural tissue regeneration.
Collapse
Affiliation(s)
- Wei Zhu
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - Tao Ye
- Department of Civil and Environmental Engineering, The George Washington University, Washington, DC, United States
| | - Se-Jun Lee
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - Haitao Cui
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - Shida Miao
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - Xuan Zhou
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA
| | - Danmeng Shuai
- Department of Civil and Environmental Engineering, The George Washington University, Washington, DC, United States
| | - Lijie Grace Zhang
- Department of Mechanical and Aerospace Engineering, The George Washington University, Washington, DC, USA; Department of Biomedical Engineering, The George Washington University, Washington, DC, USA; Department of Medicine, The George Washington University, Washington, DC, USA.
| |
Collapse
|
35
|
Goetz GA, Palanker DV. Electronic approaches to restoration of sight. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2016; 79:096701. [PMID: 27502748 PMCID: PMC5031080 DOI: 10.1088/0034-4885/79/9/096701] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Retinal prostheses are a promising means for restoring sight to patients blinded by the gradual atrophy of photoreceptors due to retinal degeneration. They are designed to reintroduce information into the visual system by electrically stimulating surviving neurons in the retina. This review outlines the concepts and technologies behind two major approaches to retinal prosthetics: epiretinal and subretinal. We describe how the visual system responds to electrical stimulation. We highlight major differences between direct encoding of the retinal output with epiretinal stimulation, and network-mediated response with subretinal stimulation. We summarize results of pre-clinical evaluation of prosthetic visual functions in- and ex vivo, as well as the outcomes of current clinical trials of various retinal implants. We also briefly review alternative, non-electronic, approaches to restoration of sight to the blind, and conclude by suggesting some perspectives for future advancement in the field.
Collapse
Affiliation(s)
- G A Goetz
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305, USA. Neurosurgery, Stanford University, Stanford, CA 94305, USA
| | | |
Collapse
|
36
|
Yue L, Weiland JD, Roska B, Humayun MS. Retinal stimulation strategies to restore vision: Fundamentals and systems. Prog Retin Eye Res 2016; 53:21-47. [DOI: 10.1016/j.preteyeres.2016.05.002] [Citation(s) in RCA: 173] [Impact Index Per Article: 21.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Revised: 05/13/2016] [Accepted: 05/21/2016] [Indexed: 11/28/2022]
|
37
|
Sekhar S, Jalligampala A, Zrenner E, Rathbun DL. Tickling the retina: integration of subthreshold electrical pulses can activate retinal neurons. J Neural Eng 2016; 13:046004. [DOI: 10.1088/1741-2560/13/4/046004] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
38
|
Im M, Fried SI. Temporal properties of network-mediated responses to repetitive stimuli are dependent upon retinal ganglion cell type. J Neural Eng 2016; 13:025002. [PMID: 26905231 PMCID: PMC4931047 DOI: 10.1088/1741-2560/13/2/025002] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To provide artificially-elicited vision that is temporally dynamic, retinal prosthetic devices will need to repeatedly stimulate retinal neurons. However, given the diversity of physiological types of retinal ganglion cells (RGCs) as well as the heterogeneity of their responses to electric stimulation, temporal properties of RGC responses have not been adequately investigated. Here, we explored the cell type dependence of network-mediated RGC responses to repetitive electric stimulation at various stimulation rates. APPROACH We examined responses of ON and OFF types of RGCs in the rabbit retinal explant to five consecutive stimuli with varying inter-stimulus intervals (10-1000 ms). Each stimulus was a 4 ms long monophasic sinusoidal cathodal current, which was applied epiretinally via a conical electrode. Spiking activity of targeted RGCs was recorded using a cell-attached patch electrode. MAIN RESULTS ON and OFF cells had distinct responses to repetitive stimuli. Consistent with earlier studies, OFF cells always generated reduced responses to subsequent stimuli compared to responses to the first stimulus. In contrast, a new stimulus to ON cells suppressed all pending/ongoing responses from previous stimuli and initiated its own response that was remarkably similar to the response from a single stimulus in isolation. This previously unreported 'reset' behavior was observed exclusively and consistently in ON cells. These contrasts between ON and OFF cells created a range of stimulation rates (4-7 Hz) that maximized the ratio of the responses arising in ON versus OFF cells. SIGNIFICANCE Previous clinical testing reported that subjects perceive bright phosphenes (ON responses) and also prefer stimulation rates of 5-7 Hz. Our results suggest that responses of ON cells are weak at high rates of stimulation (> ∼7 Hz) due to the reset while responses of OFF cells are strong at low rates (< ∼4 Hz) due to reduced desensitization, both reducing the ratio of ON to OFF responses. In combination with previous results indicating that responses in ON cells more closely match physiological patterns (Im and Fried 2015 J. Physiol. 593 3577-96), our results offer a potential reason for the user preference of intermediate rates (5-7 Hz).
Collapse
Affiliation(s)
- Maesoon Im
- VA Boston Healthcare System, 150 South Huntington Avenue, Boston, MA 02130
- Department of Neurosurgery, Massachusetts General Hospital and Harvard Medical School, 50 Blossom Street, Boston, MA 02114
| | - Shelley I. Fried
- VA Boston Healthcare System, 150 South Huntington Avenue, Boston, MA 02130
- Department of Neurosurgery, Massachusetts General Hospital and Harvard Medical School, 50 Blossom Street, Boston, MA 02114
| |
Collapse
|
39
|
Abstract
Rectangular electrical pulses are the primary stimulus waveform used in retinal prosthetics as well as many other neural stimulation applications. Unfortunately, the utility of pulsatile stimuli is limited by the inability to avoid the activation of passing axons, which can result in the distortion of the spatial patterns of elicited neural activity. Because avoiding axons would likely improve clinical outcomes, the examination of alternate stimulus waveforms is warranted. Here, we studied the response of rabbit retinal ganglion cells (RGCs) to sinusoidal electrical stimulation applied at frequencies of 5, 10, 25, and 100 Hz. Targeted RGCs were restricted to 4 common types: OFF-Brisk Transient, OFF-Sustained, ON-Brisk Transient, and ON-Sustained. Interestingly, response patterns varied between different types; the most notable difference was the relatively weak response of ON-Sustained cells to low frequencies. Calculation of total spike counts per trial revealed that lower frequencies are more charge efficient than high frequencies. Finally, experiments utilizing synaptic blockers revealed that 5 and 10 Hz activate photoreceptors while 25 and 100 Hz activate RGCs. Taken together, our results suggest that while sinusoidal electrical stimulation may provide a useful research tool, its clinical utility may be limited.
Collapse
|
40
|
Greene E. Recognizing Words and Reading Sentences with Microsecond Flash Displays. PLoS One 2016; 11:e0145697. [PMID: 26800027 PMCID: PMC4723150 DOI: 10.1371/journal.pone.0145697] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Accepted: 12/08/2015] [Indexed: 11/19/2022] Open
Abstract
Strings of dots can be used to construct easily identifiable letters, and these in turn can be used to write words and sentences. Prior work found that respondents could identify individual letters when all the dots were simultaneously flashed for an ultra-brief duration. Four of the experiments reported here constructed five-letter words with these dot-letters and a fifth experiment used them to write complete sentences. Respondents were able to recognize individual words that were displayed with a single, simultaneous ultra-brief flash of all the letters. Further, sentences could be efficiently read with a sequence of simultaneous flashes at a frequency that produced perceptual fusion. One experiment determined the frequency range that would produce flicker-fusion. Two experiments established the relation of intensity to probability of recognition with single flashes and with fused-flicker frequencies. Another established the intensities at which flicker-fused and steady displays were judged to be equal in brightness. The final experiment used those flicker-fused and steady intensities to display sentences. The two display conditions were read with equal efficiency, even though the flicker-fused displays provided light stimulation only 0.003% of the time.
Collapse
Affiliation(s)
- Ernest Greene
- Laboratory for Neurometric Research, Department of Psychology, University of Southern California, Los Angeles, California, 90089–1061, United States of America
| |
Collapse
|
41
|
Changes in morphology of retinal ganglion cells with eccentricity in retinal degeneration. Cell Tissue Res 2015; 364:263-71. [PMID: 26670589 DOI: 10.1007/s00441-015-2337-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Revised: 11/18/2015] [Accepted: 11/26/2015] [Indexed: 10/22/2022]
Abstract
Ganglion cells are the output neurons of the retina and are known to remodel during the subtle plasticity changes that occur following the death of photoreceptors in inherited retinal degeneration. We examine the influence of retinal eccentricity on anatomical remodelling and ganglion cell morphology well after photoreceptor loss. Rd1 mice that have a mutation in the β subunit of phosphodiesterase 6 were used as a model of retinal degeneration and gross remodelling events were examined by processing serial sections for immunocytochemistry. Retinal wholemounts from rd1-Thy1 and control Thy1 mice that contained a fluorescent protein labelling a subset of ganglion cells were processed for immunohistochemistry at 11 months of age. Ganglion cells were classified based on their soma size, dendritic field size and dendritic branching pattern and their dendritic fields were analysed for their length, area and quantity of branching points. Overall, more remodelling was found in the central compared with the peripheral retina. In addition, the size and complexity of A2, B1, C1 and D type ganglion cells located in the central region of the retina decreased. We propose that the changes in ganglion cell morphology are correlated with remodelling events in these regions and impact the function of retinal circuitry in the degenerated retina.
Collapse
|
42
|
Yang F, Yang CH, Wang FM, Cheng YT, Teng CC, Lee LJ, Yang CH, Fan LS. A high-density microelectrode-tissue-microelectrode sandwich platform for application of retinal circuit study. Biomed Eng Online 2015; 14:109. [PMID: 26611649 PMCID: PMC4662037 DOI: 10.1186/s12938-015-0106-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Accepted: 11/23/2015] [Indexed: 01/05/2023] Open
Abstract
Background Microelectrode array (MEA) devices are frequently used in neural circuit studies, especially in retinal prosthesis. For a high throughput stimulation and recording paradigm, it is desirable to obtain the responses of multiple surface RGCs initiated from the electrical signals delivered to multiple photoreceptor cells. This can be achieved by an high density MEA-tissue-MEA (MTM) sandwich configuration. However, the retina is one of the most metabolically active tissues, consumes oxygen as rapidly as the brain. The major concern of the MTM configuration is the supply of oxygen. Methods We aimed to develop a high density MTM sandwich platform which consists of stacks of a stimulation MEA, retinal tissue and a recording MEA. Retina is a metabolically active tissue and the firing rate is very sensitive to oxygen level. We designed, simulated and microfabricated porous high density MEAs and an adjustable perfusion system that electrical signals can be delivered to and recorded from the clipped retinal tissue. Results The porous high-density MEAs linked with stimulation or recording devices within a perfusion system were manufactured and the MTM platform was assembled with a retina slice inside. The firing rate remained constant between 25 and 55 min before dramatically declined, indicating that within certain period of time (e.g. 30 min after habituation), the retina condition was kept by sufficient oxygen supply via the perfusion holes in the MEAs provided by the double perfusion system. Conclusions MTM sandwich structure is an efficient platform to study the retinal neural circuit. The material and arrangement of high density microelectrodes with porous design make this MEA appropriate for sub-retina prosthesis. Finding ways to prolong the recording time and reduce the signal-to-noise ratio are important to improve our MTM prototype.
Collapse
Affiliation(s)
- Frank Yang
- Institute of NanoEngineering and Microsystems, National Tsing-Hua University, Hsin-Chu, Taiwan
| | - Chung-Hua Yang
- Institute of NanoEngineering and Microsystems, National Tsing-Hua University, Hsin-Chu, Taiwan
| | - Fu-Min Wang
- Institute of NanoEngineering and Microsystems, National Tsing-Hua University, Hsin-Chu, Taiwan
| | - Ya-Ting Cheng
- Institute of NanoEngineering and Microsystems, National Tsing-Hua University, Hsin-Chu, Taiwan
| | - Chih-Ciao Teng
- Institute of NanoEngineering and Microsystems, National Tsing-Hua University, Hsin-Chu, Taiwan
| | - Li-Jen Lee
- Graduated Institute of Anatomy and Cell Biology, National Taiwan University, Taipei, Taiwan
| | - Chang-Hao Yang
- Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan
| | - Long-Sheng Fan
- Institute of NanoEngineering and Microsystems, National Tsing-Hua University, Hsin-Chu, Taiwan.
| |
Collapse
|
43
|
Hadjinicolaou AE, Savage CO, Apollo NV, Garrett DJ, Cloherty SL, Ibbotson MR, O'Brien BJ. Optimizing the Electrical Stimulation of Retinal Ganglion Cells. IEEE Trans Neural Syst Rehabil Eng 2015; 23:169-78. [DOI: 10.1109/tnsre.2014.2361900] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
44
|
Davuluri NS, Weiland JD. Time-varying pulse trains limit retinal desensitization caused by continuous electrical stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:414-7. [PMID: 25569984 DOI: 10.1109/embc.2014.6943616] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
An epiretinal prosthesis aims to restore functional vision in patients suffering from retinal degeneration caused by diseases such as Retinitis Pigmentosa (RP) and Age-Related Macular Degeneration (AMD). These diseases result in the loss of photoreceptors but bipolar, amacrine and ganglion cells survive at high rates and can be electrically activate to produce the sensation of light. Continuous application of biphasic stimulus pulses results in desensitization of the retina. In humans, this manifests as decreased brightness and increased stimulus thresholds. This study presents an in vivo model of retinal desensitization caused by continuous electrical stimulation and describes a novel stimulation pattern that limit desensitization.
Collapse
|
45
|
Werginz P, Benav H, Zrenner E, Rattay F. Modeling the response of ON and OFF retinal bipolar cells during electric stimulation. Vision Res 2014; 111:170-81. [PMID: 25499837 PMCID: PMC4457536 DOI: 10.1016/j.visres.2014.12.002] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2014] [Revised: 11/11/2014] [Accepted: 12/02/2014] [Indexed: 11/15/2022]
Abstract
Retinal implants allowing blind people suffering from diseases like retinitis pigmentosa and macular degeneration to regain rudimentary vision are struggling with several obstacles. One of the main problems during external electric stimulation is the co-activation of the ON and OFF pathways which results in mutual impairment. In this study the response of ON and OFF cone retinal bipolar cells during extracellular electric stimulation from the subretinal space was examined. To gain deeper insight into the behavior of these cells sustained L-type and transient T-type calcium channels were integrated in the synaptic terminals of reconstructed 3D morphologies of ON and OFF cone bipolar cells. Intracellular calcium concentration in the synaptic regions of the model neurons was investigated as well since calcium influx is a crucial parameter for cell-to-cell activity between bipolar cells and retinal ganglion cells. It was shown that monophasic stimulation results in significant different calcium concentrations in the synaptic terminals of ON and OFF bipolar cells. Intracellular calcium increased to values up to fourfold higher in the OFF bipolar model neuron in comparison to the ON bipolar cell. Furthermore, geometric properties strongly influence the activation of bipolar cells. Monophasic, biphasic, single and repetitive pulses with similar lengths, amplitudes and polarities were applied to the two model neurons.
Collapse
Affiliation(s)
- P Werginz
- Institute for Analysis and Scientific Computing, Vienna University of Technology, 1040 Vienna, Austria
| | - H Benav
- Center for Ophthalmology, University of Tübingen, 72076 Tübingen, Germany
| | - E Zrenner
- Center for Ophthalmology, University of Tübingen, 72076 Tübingen, Germany; Center for Integrative Neurosciences, University of Tübingen, 72076 Tübingen, Germany
| | - F Rattay
- Institute for Analysis and Scientific Computing, Vienna University of Technology, 1040 Vienna, Austria.
| |
Collapse
|
46
|
Khalili Moghaddam G, Lovell NH, Wilke RGH, Suaning GJ, Dokos S. Performance optimization of current focusing and virtual electrode strategies in retinal implants. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2014; 117:334-342. [PMID: 25023532 DOI: 10.1016/j.cmpb.2014.06.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2013] [Revised: 06/23/2014] [Accepted: 06/23/2014] [Indexed: 06/03/2023]
Abstract
The electrode configuration in an implanted visual prosthesis array affects the spatial electric field distribution within the retina, contributing to current focusing and virtual electrode (VE) stimulation strategies. In this paper, a finite element model incorporating various electrode configurations was used to study the interaction between electrode size and electrode-to-cell distance in current focusing and VE stimulation paradigms. The electrode array unit comprises an active electrode, six flanking return electrodes and a distant monopolar return. A quasi-monopolar (QMP) fraction is defined as the proportion of current which can be preferentially returned through the distant return, in comparison with the more adjacent flanking electrodes. The simulation results indicate that current focusing and VE strategies can be optimized by tuning the QMP fraction. The QMP fraction is adjusted to optimize the electric field spread based on retinal ganglion cell (RGC) density in the degenerate retina, thereby offsetting the effect of inhomogeneous distribution of surviving RGCs and leading to a uniform stimulation paradigm across electrodes. Importantly, there is negligible difference in functional performance across electrode configurations for distances less than the electrode diameter, implying that the stimulation mode does not significantly affect activation threshold or activated retinal area for electrode diameters greater than the retinal thickness. Furthermore, the QMP fraction has a significant effect on VE performance, defined by activation threshold and activated retinal area, when threshold current is evenly divided between two adjacent active electrodes.
Collapse
Affiliation(s)
- Gita Khalili Moghaddam
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Nigel H Lovell
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Robert G H Wilke
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Gregg J Suaning
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Socrates Dokos
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
| |
Collapse
|
47
|
Villalobos J, Fallon JB, Nayagam DAX, Shivdasani MN, Luu CD, Allen PJ, Shepherd RK, Williams CE. Cortical activation following chronic passive implantation of a wide-field suprachoroidal retinal prosthesis. J Neural Eng 2014; 11:046017. [PMID: 24965866 DOI: 10.1088/1741-2560/11/4/046017] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The research goal is to develop a wide-field retinal stimulating array for prosthetic vision. This study aimed at evaluating the efficacy of a suprachoroidal electrode array in evoking visual cortex activity after long term implantation. APPROACH A planar silicone based electrode array (8 mm × 19 mm) was implanted into the suprachoroidal space in cats (ntotal = 10). It consisted of 20 platinum stimulating electrodes (600 μm diameter) and a trans-scleral cable terminated in a subcutaneous connector. Three months after implantation (nchronic = 6), or immediately after implantation (nacute = 4), an electrophysiological study was performed. Electrode total impedance was measured from voltage transients using 500 μs, 1 mA pulses. Electrically evoked potentials (EEPs) and multi-unit activity were recorded from the visual cortex in response to monopolar retinal stimulation. Dynamic range and cortical activation spread were calculated from the multi-unit recordings. MAIN RESULTS The mean electrode total impedance in vivo following 3 months was 12.5 ± 0.3 kΩ. EEPs were recorded for 98% of the electrodes. The median evoked potential threshold was 150 nC (charge density 53 μC cm(-2)). The lowest stimulation thresholds were found proximal to the area centralis. Mean thresholds from multiunit activity were lower for chronic (181 ± 14 nC) compared to acute (322 ± 20 nC) electrodes (P < 0.001), but there was no difference in dynamic range or cortical activation spread. SIGNIFICANCE Suprachoroidal stimulation threshold was lower in chronic than acute implantation and was within safe charge limits for platinum. Electrode-tissue impedance following chronic implantation was higher, indicating the need for sufficient compliance voltage (e.g. 12.8 V for mean impedance, threshold and dynamic range). The wide-field suprachoroidal array reliably activated the retina after chronic implantation.
Collapse
|
48
|
Abstract
Retinal prosthesis has been translated from the laboratory to the clinic over the past two decades. Currently, two devices have regulatory approval for the treatment of retinitis pigmentosa. These devices provide partial sight restoration and patients use this improved vision in their everyday lives. Improved mobility and object detection are some of the more notable findings from the clinical trials. However, significant vision restoration will require both better technology and improved understanding of the interaction between electrical stimulation and the retina. This paper reviews the recent clinical trials and highlights technology breakthroughs that will contribute to next generation of retinal prostheses.
Collapse
|
49
|
Zhu Q, Su G, Nie L, Wang C, He Y, Liu X. Salvia miltiorrhiza extracts protect against retinal injury in a rat glaucoma model. Exp Ther Med 2014; 7:1513-1515. [PMID: 24926334 PMCID: PMC4043585 DOI: 10.3892/etm.2014.1632] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Accepted: 03/13/2014] [Indexed: 12/26/2022] Open
Abstract
Glaucoma is a serious progressive degenerative disorder of the eye that leads to the continuous loss of retinal ganglion cells. Traditional Chinese medicine provides an important source for new drug screening and identification. The present study used Salvia miltiorrhiza (Danshen) extracts to examine the potential neuroprotective effects for the eye in a rat model of experimental glaucoma. The results of the study indicated that Salvia miltiorrhiza extracts were unable to prevent intraocular pressure increase in the laser-induced glaucoma model, but the treatment did reduce cell loss during glaucoma progression. Therefore, the results provide the basis for the development of a novel therapeutic agent that exhibits neuroprotective effects against glaucoma. In the future, further studies are required to purify the extracts and determine the effective bioactive components of Salvia miltiorrhiza.
Collapse
Affiliation(s)
- Qi Zhu
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, Jilin 130041, P.R. China
| | - Guanfang Su
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, Jilin 130041, P.R. China
| | - Lili Nie
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, Jilin 130041, P.R. China
| | - Chenguang Wang
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, Jilin 130041, P.R. China
| | - Yuxi He
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, Jilin 130041, P.R. China
| | - Xin Liu
- Department of Ophthalmology, The Second Hospital of Jilin University, Changchun, Jilin 130041, P.R. China
| |
Collapse
|
50
|
Abramian M, Lovell NH, Habib A, Morley JW, Suaning GJ, Dokos S. Quasi-monopolar electrical stimulation of the retina: a computational modelling study. J Neural Eng 2014; 11:025002. [PMID: 24556561 DOI: 10.1088/1741-2560/11/2/025002] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE In this study we investigated the feasibility of quasi-monopolar (QMP) electrical stimulation for retinal implant devices, using a computational model of the retinal ganglion cell layer. APPROACH When used with hexagonally arrayed multiple electrodes, QMP stimulation is a hybrid of hexapolar and conventional monopolar stimulus modes. In hexapolar mode, each active electrode is surrounded by six guards which collectively return the stimulus current, whereas in monopolar mode the injected stimulus current is returned through a distant return electrode. The QMP paradigm, on the other hand, distributes the return current between the guard electrodes as well as the distant return. The electrodes tested were 25, 50 and 100 µm in diameter, with hexagonally arranged centre-to-centre spacing of either double or quadruple this diameter. MAIN RESULTS Simulation results indicated that electrode size had minimal effects on subretinal threshold currents, whilst electrode configuration and centre-to-centre spacing played major roles in determining thresholds and spatial activation patterns. Threshold charge densities for 50 and 100 µm electrodes were generally within the safe limit. SIGNIFICANCE We found that QMP stimulation offers greater advantages compared to monopolar and hexapolar stimulation, in that it combines the low thresholds of monopolar stimulation with the localized spatial activation achieved with hexapolar electrodes during parallel stimulation.
Collapse
Affiliation(s)
- Miganoosh Abramian
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | | | | | | | | | | |
Collapse
|