1
|
Alessandri-Gradt E, Unal G, Baron A, Leoz M, Gueudin M, Plantier JC. Performance Analysis of Three Commercial Kits Designed for RNA Quantification of HIV-1 Group O Variants. J Acquir Immune Defic Syndr 2021; 88:220-227. [PMID: 34506362 DOI: 10.1097/qai.0000000000002753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 05/24/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND The genetic divergence of HIV-1 group O is high relative to pandemic group M, which could impact detection and quantification of plasma RNA. Recent commercial kits for RNA quantification seem to show good performances in HIV-1/O, but discrepancies are still observed. Here, we compare the performances of 3 commercial assays for the RNA quantification of HIV-1/O. METHODS We studied the RNA quantification of 117 clinical samples using Abbott RealTime HIV-1, Cepheid Xpert HIV-1 Viral Load, or Roche Cobas TaqMan HIV-1 v2. First, we conducted a qualitative description, and second, we focused on a quantitative analysis of the results above 40 cp/mL. The degree of agreement between methods and the strength of the correlation of viral load determination were estimated using Bland-Altman plot and Passing-Bablok regression with the Spearman coefficient, respectively. RESULTS Our 2-by-2 analysis showed that the Abbott and Cepheid assays were very close in terms of correlation and dispersion of points, whereas Roche presented higher values in the highest range of quantification (>5 log10). The Cepheid assay combined better correlation with the consensus value and a lower dispersion of values, leading to an overall better performance of quantification. The quantification was still impacted by intragroup genetic diversity with, here, 1 strain (YBF26). CONCLUSIONS Using a new approach to compare the performances of RNA quantification between more than 2 techniques, we demonstrated that Cepheid could be the most suitable assay for HIV-1/O quantification, although the results from all assays remained strain dependent.
Collapse
Affiliation(s)
- Elodie Alessandri-Gradt
- Normandie Univ, UNIROUEN, EA2656, GRAM 2.0, et CHU de Rouen, Laboratoire de Virologie associé au CNR du VIH, Rouen, France; and
| | - Guillemette Unal
- Normandie Univ, UNIROUEN, EA2656, GRAM 2.0, et CHU de Rouen, Laboratoire de Virologie associé au CNR du VIH, Rouen, France; and
| | - Adeline Baron
- CHU de Rouen, Laboratoire de Virologie associé au CNR du VIH, Rouen, France
| | - Marie Leoz
- Normandie Univ, UNIROUEN, EA2656, GRAM 2.0, et CHU de Rouen, Laboratoire de Virologie associé au CNR du VIH, Rouen, France; and
| | - Marie Gueudin
- Normandie Univ, UNIROUEN, EA2656, GRAM 2.0, et CHU de Rouen, Laboratoire de Virologie associé au CNR du VIH, Rouen, France; and
| | - Jean-Christophe Plantier
- Normandie Univ, UNIROUEN, EA2656, GRAM 2.0, et CHU de Rouen, Laboratoire de Virologie associé au CNR du VIH, Rouen, France; and
| |
Collapse
|
2
|
Mossoro-Kpinde CD, Jenabian MA, Gody JC, Robin L, Talla P, Longo J, Grésenguet G, Belec L. Evaluation of the Upgraded Version 2.0 of the Roche COBAS ® AmpliPrep/COBAS ® TaqMan HIV-1 Qualitative Assay in Central African Children. Open AIDS J 2016; 10:158-163. [PMID: 27857825 PMCID: PMC5091015 DOI: 10.2174/1874613601610010158] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2016] [Revised: 05/03/2016] [Accepted: 05/30/2016] [Indexed: 11/22/2022] Open
Abstract
Background: Several commercially available molecular techniques were developed based on subtype B of HIV-1, which represents only 10% of HIV strains worldwide. Indeed, in sub-Saharan Africa, non-B subtypes of HIV-1 are predominant. The aim of this study was to evaluate the performances of the COBAS® AmpliPrep/COBAS® (CAP/CTM) HIV-1 Qualitative assays to detect the broad range of HIV-1 variants circulating in Central Africa and compare to the outgoing CAP/CTM HIV-1 Quantitative test v2.0 (Roche Molecular Systems), chosen as reference gold standard molecular assay. Methods: The CAP/CTM HIV-1 Qualitative tests versions 1.0 and 2.0 (Roche Molecular Systems, Inc., Branchburg, NJ, USA) were evaluated compared to CAP/CTM TaqMan HIV-1 Quantitative test v2.0 (Roche Molecular Systems) on 239 dried plasma spot (DPS) from 133 HIV-1-infected (with detectable plasma HIV RNA load) and 106 uninfected children, followed-up at Complexe Pédiatrique, Bangui, Central African Republic. Results: The version 1.0 showed low sensitivity (93.2%), with 9 (6.8%) false negative results, demonstrating under-detection of non-B HIV-1 subtypes. In contrast, the upgraded version 2.0 showed 100%-sensitivity, 100%-specificity and perfect agreement (κ coefficient, 1.0). Conclusion: Our evaluation in the Central African Republic demonstrates the clinical implications of the accuracy and reliability of the CAP/CTM HIV-1 Qualitative assay for early diagnosis of HIV-1 in Central African children.
Collapse
Affiliation(s)
- C D Mossoro-Kpinde
- Laboratoire National de Biologie Clinique et de Santé Publique, Bangui, Central African Republic; Faculté des Sciences de la Santé, Université de Bangui, Bangui, Central African Republic
| | - M A Jenabian
- Department of Biological Sciences and BioMed Research Center, Université du Québec ā Montréal (UQAM), Montreal, Canada
| | - J C Gody
- Faculté des Sciences de la Santé, Université de Bangui, Bangui, Central African Republic; Complexe Pédiatrique, Bangui, Central African Republic
| | - L Robin
- Laboratoire de virologie, hôpital Européen Georges Pompidou, and Université Paris Descartes, Paris Sorbonne Cité, Paris, France
| | - P Talla
- Laboratoire de virologie, hôpital Européen Georges Pompidou, and Université Paris Descartes, Paris Sorbonne Cité, Paris, France
| | - Jdd Longo
- Faculté des Sciences de la Santé, Université de Bangui, Bangui, Central African Republic
| | - G Grésenguet
- Faculté des Sciences de la Santé, Université de Bangui, Bangui, Central African Republic
| | - L Belec
- Laboratoire de virologie, hôpital Européen Georges Pompidou, and Université Paris Descartes, Paris Sorbonne Cité, Paris, France
| |
Collapse
|
3
|
Odari EO, Maiyo A, Lwembe R, Gurtler L, Eberle J, Nitschko H. Establishment and evaluation of a loop-mediated isothermal amplification (LAMP) assay for the semi-quantitative detection of HIV-1 group M virus. J Virol Methods 2014; 212:30-8. [PMID: 25445795 DOI: 10.1016/j.jviromet.2014.10.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Revised: 09/29/2014] [Accepted: 10/28/2014] [Indexed: 10/24/2022]
Abstract
The past decade has witnessed a dramatic increase of anti-retroviral treatment of human immunodeficiency virus (HIV) infected patients in many African countries. Due to costs and lack of currently available commercial viral load assays, insufficient attention has been paid to therapy monitoring through measurement of plasma viral load. This challenge of patient monitoring by tests as viral load, CD4 cell count, and finally HIV drug resistance could reverse achievements already made against HIV/AIDS infection. Loop-mediated isothermal amplification (LAMP) has been shown to be simple, rapid and cost-effective, characteristics which make this assay suitable for viral load monitoring in resource limited settings. This paper describes a revised LAMP assay using primers in the HIV-1 integrase region. The assay can be used for semi-quantitative measurement of HIV-1 group M viral load. The lower limit of detection (LLOD) was determined as 1200copies/mL and lower limit of quantitation (LLOQ) at 9800copies/mL. Sensitivities of 82 and 86% (in 135 and 99 plasma samples respectively from Kenya) and 93% (in 112 plasma samples from Germany) and specificities of 99 and 100% were realized. HIV-1 group O and HIV-2 virus samples were not detected. This LAMP assay has the potential for semi-quantitation of HIV-1 group M viral load in resource limited countries. There is still a need for further improvement by refinement of primers in respect to detection of HIV-1 group M non-B virus.
Collapse
Affiliation(s)
- Eddy Okoth Odari
- Max von Pettenkofer-Institute for Hygiene and Medical Microbiology (MVPI), Ludwig-Maximilians-University, Pettenkofer Strasse 9a, 80336 Munich, Germany; Center for International Health (CIH) at the Ludwig-Maximilians-University, Leopoldstraße 7, 80802 Munich, Germany; Department of Medical Microbiology, Jomo Kenyatta University of Agriculture and Technology, P.O. Box 62 000, 00200 Nairobi, Kenya.
| | - Alex Maiyo
- Kenya Medical Research Institute (KEMRI), Mbagathi, P.O. Box 54840, Nairobi, Kenya
| | - Raphael Lwembe
- Kenya Medical Research Institute (KEMRI), Mbagathi, P.O. Box 54840, Nairobi, Kenya
| | - Lutz Gurtler
- Max von Pettenkofer-Institute for Hygiene and Medical Microbiology (MVPI), Ludwig-Maximilians-University, Pettenkofer Strasse 9a, 80336 Munich, Germany
| | - Josef Eberle
- Max von Pettenkofer-Institute for Hygiene and Medical Microbiology (MVPI), Ludwig-Maximilians-University, Pettenkofer Strasse 9a, 80336 Munich, Germany
| | - Hans Nitschko
- Max von Pettenkofer-Institute for Hygiene and Medical Microbiology (MVPI), Ludwig-Maximilians-University, Pettenkofer Strasse 9a, 80336 Munich, Germany
| |
Collapse
|
4
|
An international collaboration to standardize HIV-2 viral load assays: results from the 2009 ACHI(E)V(2E) quality control study. J Clin Microbiol 2011; 49:3491-7. [PMID: 21813718 DOI: 10.1128/jcm.02389-10] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Accurate HIV-2 plasma viral load quantification is crucial for adequate HIV-2 patient management and for the proper conduct of clinical trials and international cohort collaborations. This study compared the homogeneity of HIV-2 RNA quantification when using HIV-2 assays from ACHI(E)V(2E) study sites and either in-house PCR calibration standards or common viral load standards supplied to all collaborators. Each of the 12 participating laboratories quantified blinded HIV-2 samples, using its own HIV-2 viral load assay and standard as well as centrally validated and distributed common HIV-2 group A and B standards (http://www.hiv.lanl.gov/content/sequence/HelpDocs/subtypes-more.html). Aliquots of HIV-2 group A and B strains, each at 2 theoretical concentrations (2.7 and 3.7 log(10) copies/ml), were tested. Intralaboratory, interlaboratory, and overall variances of quantification results obtained with both standards were compared using F tests. For HIV-2 group A quantifications, overall and interlaboratory and/or intralaboratory variances were significantly lower when using the common standard than when using in-house standards at the concentration levels of 2.7 log(10) copies/ml and 3.7 log(10) copies/ml, respectively. For HIV-2 group B, a high heterogeneity was observed and the variances did not differ according to the type of standard used. In this international collaboration, the use of a common standard improved the homogeneity of HIV-2 group A RNA quantification only. The diversity of HIV-2 group B, particularly in PCR primer-binding regions, may explain the heterogeneity in quantification of this strain. Development of a validated HIV-2 viral load assay that accurately quantifies distinct circulating strains is needed.
Collapse
|
5
|
Correction of underquantification of human immunodeficiency virus type 1 load with the second version of the Roche Cobas AmpliPrep/Cobas TaqMan assay. J Clin Microbiol 2010; 48:1337-42. [PMID: 20164284 DOI: 10.1128/jcm.01226-09] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Initial evaluations of the Cobas AmpliPrep/Cobas TaqMan human immunodeficiency virus type 1 (HIV-1) test (CAP/CTM) demonstrated good performance but, afterwards, reports about underquantification were published. We investigated whether the problem was solved with a second version of this assay, the Cobas AmpliPrep/Cobas TaqMan HIV-1 test, version 2.0 (CAP/CTM v2.0). The remaining plasma of 375 consecutive HIV-1 positive samples with a viral load of >or=4,000 copies/ml was collected in three laboratories. The samples were diluted and retested with our routine method Cobas AmpliPrep/Cobas Amplicor HIV-1 monitor test v1.5 in ultrasensitive mode (CAP/CA PHS), as well as with the CAP/CTM and CAP/CTM v2.0 tests. An absolute difference between the results of two methods of >or=0.71 log(10) copies/ml was defined as moderately discrepant, and an absolute difference of >or=0.93 log(10) copies/ml was defined as severely discrepant. In addition, criteria for considering the new methods equivalent to the routine method were formulated. (i) For CAP/CTM compared to CAP/CA PHS, 36 (9.5%) and 20 (5.3%) samples were, respectively, considered moderately and severely underquantified by CAP/CTM. The mean difference between CAP/CTM and CAP/CA PHS was -0.32 log(10) copies/ml. Eight of nineteen of the severely underquantified samples were from patients infected with HIV-1 subtype B strain. (ii) For CAP/CTM v2.0 compared to CAP/CA PHS, no sample was moderately or severely underquantified by CAP/CTM v2.0. A mean difference of 0.08 log(10) copies/ml was found with CAP/CTM v2.0 compared to CAP/CA PHS. The underquantification problem of the CAP/CTM kit was clearly demonstrated. The criteria for the equivalence of CAP/CTM v2.0 to the routine test CAP/CA PHS were fulfilled.
Collapse
|
6
|
Evaluation of an upgraded version of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test for HIV-1 load quantification. J Clin Microbiol 2010; 48:1413-6. [PMID: 20129964 DOI: 10.1128/jcm.01409-09] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We evaluated the performance of the prototype Cobas AmpliPrep/Cobas TaqMan HIV-1 test, version 2.0, using prospective and archived clinical samples initially underquantitated by the Cobas AmpliPrep/Cobas TaqMan HIV-1 test. The performance of the new test was significantly improved, and the majority of the underquantitation observed with the first-version test was eliminated.
Collapse
|
7
|
Damond F, Roquebert B, Bénard A, Collin G, Miceli M, Yéni P, Brun-Vezinet F, Descamps D. Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 assays. J Clin Microbiol 2007; 45:3436-8. [PMID: 17715371 PMCID: PMC2045351 DOI: 10.1128/jcm.00973-07] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We compared plasma viral load values obtained with COBAS AMPLICOR human immunodeficiency virus type 1 (HIV-1) MONITOR version 1.5 and with COBAS TaqMan HIV-1 assays. Mean values were 4.2 and 2.9 log(10) copies/ml, respectively, showing the lack of agreement between the two assays.
Collapse
Affiliation(s)
- F Damond
- Laboratoire de Virologie, Hôpital Bichat Claude Bernard, 75018 Paris, France.
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Apetrei C, Gautam R, Sumpter B, Carter AC, Gaufin T, Staprans SI, Else J, Barnes M, Cao R, Garg S, Milush JM, Sodora DL, Pandrea I, Silvestri G. Virus subtype-specific features of natural simian immunodeficiency virus SIVsmm infection in sooty mangabeys. J Virol 2007; 81:7913-23. [PMID: 17507488 PMCID: PMC1951324 DOI: 10.1128/jvi.00281-07] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Simian immunodeficiency virus (SIV) SIV(smm) naturally infects sooty mangabeys (SMs) and is the source virus of pathogenic infections with human immunodeficiency virus type 2 (HIV-2) and SIV(mac) of humans and macaques, respectively. In previous studies we characterized SIV(smm) diversity in naturally SIV-infected SMs and identified nine different phylogenetic subtypes whose genetic distances are similar to those reported for the different HIV-1 group M subtypes. Here we report that, within the colony of SMs housed at the Yerkes National Primate Research Center, at least four SIV(smm) subtypes cocirculate, with the vast majority of animals infected with SIV(smm) subtype 1, 2, or 3, resulting in the emergence of occasional recombinant forms. While SIV(smm)-infected SMs show a typically nonpathogenic course of infection, we have observed that different SIV(smm) subtypes are in fact associated with specific immunologic features. Notably, while subtypes 1, 2, and 3 are associated with a very benign course of infection and preservation of normal CD4+ T-cell counts, three out of four SMs infected with subtype 5 show a significant depletion of CD4+ T cells. The fact that virus replication in SMs infected with subtype 5 is similar to that in SMs infected with other SIV(smm) subtypes suggests that the subtype 5-associated CD4+ T-cell depletion is unlikely to simply reflect higher levels of virus-mediated direct killing of CD4+ T-cells. Taken together, this systematic analysis of the subtype-specific features of SIV(smm) infection in natural SM hosts identifies subtype-specific differences in the pathogenicity of SIV(smm) infection.
Collapse
Affiliation(s)
- Cristian Apetrei
- Division of Microbiology and Immunology, Tulane National Primate Research Center, 18703 Three Rivers Road, Covington, LA 70433, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Gueudin M, Plantier JC, Lemée V, Schmitt MP, Chartier L, Bourlet T, Ruffault A, Damond F, Vray M, Simon F. Evaluation of the Roche Cobas TaqMan and Abbott RealTime extraction-quantification systems for HIV-1 subtypes. J Acquir Immune Defic Syndr 2007; 44:500-5. [PMID: 17259908 DOI: 10.1097/qai.0b013e31803260df] [Citation(s) in RCA: 109] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES We conducted a comparison of the Abbott Molecular RealTime (Rungis, France) and Roche Diagnostics Cobas Taqman (Meylan, France) automated nucleic acid extraction and real-time polymerase chain reaction (PCR) amplification systems for their capacity to quantify HIV RNA of various subtypes. The systems were tested on culture supernatants belonging to HIV-1 group M (n = 29), HIV-1 group O (n = 8), and HIV-2 (n = 7). We also tested 88 plasma samples from patients infected with HIV-1 group M (B-D [n = 7], A-CRF01 [n = 16], CRF02 [n = 49], and other strains [n = 16]). RESULTS The Abbott RealTime system quantified all 29 HIV-1 group M supernatants. One of these samples was not detected by the Roche Cobas TaqMan system. The Abbott RealTime system quantified 7 HIV-1 group O strains. Neither technique cross-reacted with HIV-2. The 79% intraclass correlation coefficient for the 88 plasma samples was barely acceptable, but 4 plasma samples were underestimated by more than 1 log by the Roche Cobas TaqMan system. Similar values were obtained for subtype B and D strains with the tests, indicating that the primers and probes are suitable for these strains. In contrast, the large differences observed with other subtypes, particularly CRF02, show the importance of primer and probe selection. CONCLUSION The limitation of real-time PCR to span the entire diversity of HIV must be taken into account during treatment monitoring, resistance studies, and clinical trials.
Collapse
Affiliation(s)
- Marie Gueudin
- Laboratoire de Virologie, Equipe d'accueil 2656, Centre Hospitalier Universitaire Charles Nicolle, 1 rue de Germont, 76031 Rouen, France.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Fonquernie L, Eholié SP, Damond F, Lacombe K, Girard PM. Failure of HIV-2 viral load assay in a severely immunodeficient patient: clinical and therapeutic management issues. Trans R Soc Trop Med Hyg 2006; 100:282-4. [PMID: 16293278 DOI: 10.1016/j.trstmh.2005.08.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2004] [Revised: 08/10/2005] [Accepted: 08/10/2005] [Indexed: 11/18/2022] Open
Abstract
We report the case of an HIV-2-infected patient with severe immunosupression despite undetectable plasma HIV-2 RNA. This immunovirological discordance was due to failure of the viral load assay and infection by an unknown HIV-2 subtype. Treatment was probably suboptimal, leading to the selection of several resistance mutations and treatment failure.
Collapse
Affiliation(s)
- Laurent Fonquernie
- Service des Maladies Infectieuses et Tropicales, Hôpital Saint-Antoine, Assistance Publique-Hôpitaux de Paris, 184 rue du faubourg Saint-Antoine, 75012 Paris, France.
| | | | | | | | | |
Collapse
|
11
|
Hawkins D, Blott M, Clayden P, de Ruiter A, Foster G, Gilling-Smith C, Gosrani B, Lyall H, Mercey D, Newell ML, O'Shea S, Smith R, Sunderland J, Wood C, Taylor G. Guidelines for the management of HIV infection in pregnant women and the prevention of mother-to-child transmission of HIV. HIV Med 2005; 6 Suppl 2:107-48. [PMID: 16033339 DOI: 10.1111/j.1468-1293.2005.00302.x] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
MESH Headings
- Antiretroviral Therapy, Highly Active/adverse effects
- Antiretroviral Therapy, Highly Active/statistics & numerical data
- Attitude to Health
- Child Health Services/organization & administration
- Delivery, Obstetric/methods
- Disclosure
- Drug Combinations
- Drug Resistance, Viral
- Female
- HIV Infections/drug therapy
- HIV Infections/prevention & control
- HIV Infections/transmission
- HIV-1
- HIV-2
- Hepatitis, Viral, Human/complications
- Hepatitis, Viral, Human/diagnosis
- Humans
- Infant Nutritional Physiological Phenomena
- Infant, Newborn
- Infectious Disease Transmission, Vertical/prevention & control
- Maternal Welfare
- Perinatal Care/methods
- Preconception Care/methods
- Pregnancy
- Pregnancy Complications, Infectious/drug therapy
- Pregnancy Complications, Infectious/prevention & control
- Pregnancy Outcome
- Prenatal Care/methods
- Referral and Consultation
- Viral Load
Collapse
Affiliation(s)
- D Hawkins
- Chelsea and Westimnster Hospital, London, UK.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Damond F, Collin G, Descamps D, Matheron S, Pueyo S, Taieb A, Campa P, Benard A, Chêne G, Brun-Vezinet F. Improved sensitivity of human immunodeficiency virus type 2 subtype B plasma viral load assay. J Clin Microbiol 2005; 43:4234-6. [PMID: 16081987 PMCID: PMC1233899 DOI: 10.1128/jcm.43.8.4234-4236.2005] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We developed a new assay for human immunodeficiency virus type 2 plasma RNA quantification based on a previous format. The new version performed significantly better than the original regarding the detection of subtype B, allowing the detection of 14 out of 36 plasma RNAs in the subtype B-infected patients not detected with the original version.
Collapse
Affiliation(s)
- Florence Damond
- Laboratoire de Virologie, Hôpital Bichat Claude Bernard, 46 rue Henri Huchard, 75018 Paris, France.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Abstract
Since the beginning of the AIDS epidemic in 1981, HIV-1 has demonstrated an amazing ability to mutate. HIV-1 was introduced into the human population in the early to mid twentieth century in central Africa. During ensuing decades, this extraordinary mutational capacity has resulted in the circulation of HIV-1 strains that are quite different from one another, yet still remarkably pathogenic. The potential impact of this viral diversity on treatment, monitoring,and vaccine development is discussed.
Collapse
Affiliation(s)
- Cristian Apetrei
- Tulane National Primate Research Center and Department of Tropical Medicine, Tulane University Health Sciences Center, Covington, LA 70433, USA
| | | | | |
Collapse
|
14
|
Amendola A, Bordi L, Angeletti C, Girardi E, Ippolito G, Capobianchi MR. Comparison of LCx with other current viral load assays for detecting and quantifying human immunodeficiency virus type 1 RNA in patients infected with the circulating recombinant form A/G (CRF02). J Clin Microbiol 2004; 42:811-5. [PMID: 14766858 PMCID: PMC344458 DOI: 10.1128/jcm.42.2.811-815.2004] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
LCx was compared to other assays in measuring human immunodeficiency virus type 1 (HIV-1) CRF02 viremia. LCx showed significant but low correlation with the other methods. Values of <2.60 log(10) cp/ml were observed in 29.6% of specimens with LCx and in only 14.8% with bDNA and PCR, suggesting suboptimal performance of LCx with CRF02.
Collapse
Affiliation(s)
- Alessandra Amendola
- National Institute for Infectious Diseases "Lazzaro Spallanzani," Rome, Italy
| | | | | | | | | | | |
Collapse
|
15
|
Pandrea I, Onanga R, Kornfeld C, Rouquet P, Bourry O, Clifford S, Telfer PT, Abernethy K, White LTW, Ngari P, Müller-Trutwin M, Roques P, Marx PA, Simon F, Apetrei C. High levels of SIVmnd-1 replication in chronically infected Mandrillus sphinx. Virology 2004; 317:119-27. [PMID: 14675630 DOI: 10.1016/j.virol.2003.08.015] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Viral loads were investigated in SIVmnd-1 chronically infected mandrills and the results were compared with those previously observed in other nonpathogenic natural SIV infections. Four naturally and 11 experimentally SIVmnd-1-infected mandrills from a semi-free-ranging colony were studied during the chronic phase of infection. Four SIVmnd-1-infected wild mandrills were also included for comparison. Twelve uninfected mandrills were used as controls. Viral loads in all chronically infected mandrills ranged from 10(5) to 9 x 10(5) copies/ml and antibody titers ranged from 200 to 14,400 and 200 to 12,800 for anti-V3 and anti-gp36, respectively. There were no differences between groups of wild and captive mandrills. Both parameters were stable during the follow-up, and no clinical signs of immune suppression were observed. Chronic SIVmnd-1-infected mandrills presented slight increases in CD20+ and CD28+/CD8+ cell counts, and a slight decrease in CD4+/CD3+ cell counts. A slight CD4+/CD3+ cell depletion was also observed in old uninfected controls. Similar to other nonpathogenic models of lentiviral infection, these results show a persistent high level of SIVmnd-1 replication during chronic infection of mandrills, with minimal effects on T cell subpopulations.
Collapse
Affiliation(s)
- Ivona Pandrea
- Laboratoire de Virologie, UGENET, SEGC, Réserve de la Lopé, Centre de Primatologie, Centre International de Recherches Médicales, BP769, Franceville, Gabon, France
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Plantier JC, Gueudin M, Damond F, Braun J, Mauclère P, Simon F. Plasma RNA quantification and HIV-1 divergent strains. J Acquir Immune Defic Syndr 2003; 33:1-7. [PMID: 12792348 DOI: 10.1097/00126334-200305010-00001] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The diversity of HIV complicates viral load measurement for patient management and treatment monitoring. Numerous studies have shown that non-B group M variants can be underestimated and that group O strains are not detected by commercial tests. More recent versions of the kits used for previous studies have improved the quantification of non-B variants but are still unable to detect or correctly quantify group O strains. In this study, the authors evaluated the new Abbott LCx HIV RNA Quantitative viral load kit with a large collection of samples from Europe and central Africa. One hundred thirty-three group M samples, including 69 from patients infected with non-B variants, and 70 group O samples were tested. The LCx system was compared with the Cobas Amplicor HIV-1 Monitor v1.5 test and with a quantitative real-time polymerase chain reaction method based on LightCycler technology. The LCx and Cobas tests had similar quantification ranges for group M samples and a high degree of linearity (r2 = 0.9582). The LCx method quantified group O variants (31 of the 48 patients were quantifiable) and gave values within the range of those obtained with the LightCycler assay. The two assays were sensitive but showed only moderate linearity (r2 = 0.6195), probably because of higher diversity of group O strains and the use of primers and probes in different regions. In conclusion, the authors showed that the LCx kit allowed quantification of the large group M diversity and group O variants.
Collapse
|
17
|
Amendola A, Bordi L, Angeletti C, Visco-Comandini U, Abbate I, Cappiello G, Budabbus MA, Eljhawi OA, Mehabresh MI, Girardi E, Antinori A, Ippolito G, Capobianchi MR. Underevaluation of HIV-1 plasma viral load by a commercially available assay in a cluster of patients infected with HIV-1 A/G circulating recombinant form (CRF02). J Acquir Immune Defic Syndr 2002; 31:488-94. [PMID: 12473837 DOI: 10.1097/00126334-200212150-00006] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The authors studied the correlation and agreement of commercially available assays in detection and quantification of the HIV-1 intersubtype A/G circulating recombinant form CRF02. The assays under comparison were Bayer Versant HIV-1 RNA, version 3.0; Roche Amplicor HIV-1 Monitor, version 1.5 (standard procedure); and Organon Teknika NucliSens HIV-1 RNA QT. Plasma samples from 114 patients infected with CRF02 were tested by the three assays under standard conditions. Although correlation among the assays was high and statistically significant for subtype B and CRF02, in the latter instance, NucliSens measured average viral load values (3.29 +/- 0.71 log(10) copies/mL) about 4 and >8 times lower than those obtained by Versant (3.90 +/- 0.90 log(10) copies/mL) and Amplicor (4.22 +/- 1.05 log(10) copies/mL), respectively. Furthermore, in a statistically significant percentage of CRF02-harboring samples, NucliSens produced viral load values undetectable or 1 log(10) lower than those obtained in Versant and Amplicor assays. Altogether, these data underline a low performance of NucliSens in detecting and quantifying viremia in plasma samples harboring the CRF02. These results are potentially important as global distribution of new HIV-1 subtypes is expanding, and recombinant strains, particularly CRF02, are emerging and becoming highly prevalent.
Collapse
Affiliation(s)
- Alessandra Amendola
- Laboratory of Virology, National Institute for Infectious Diseases, Lazzaro Spallanzani IRCCS, Via Portuense 292, 00149 Rome, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Pandrea I, Robertson DL, Onanga R, Gao F, Makuwa M, Ngari P, Bedjabaga I, Roques P, Simon F, Apetrei C. Analysis of partial pol and env sequences indicates a high prevalence of HIV type 1 recombinant strains circulating in Gabon. AIDS Res Hum Retroviruses 2002; 18:1103-16. [PMID: 12396449 DOI: 10.1089/088922202320567842] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Forty-one HIV-1 strains from Gabonese patients were studied according to the following strategy: nested polymerase chain reaction were performed to obtain an approximately 1,100-bp fragment containing the protease gene and the 5' half of the reverse transcriptase gene. Additional amplifications were carried out to obtain an approximately 700-bp fragment encompassing the C2V3 env gene. Fragments of 600 to 1,200 bp in the gag gene overlapping the pol sequences were used for the study of recombination patterns. Phylogenetic analyses of the different fragments were used to investigate HIV-1 diversity in Gabon. Thirty-one strains were sequenced in the env and pol genes and phylogenetic analyses classified them as subtype A (n = 2), D (n = 4), G (n = 1), H (n = 1), CRF02 (n = 8), and CRF MAL-like (n = 6); in addition, there were 6 unique recombinant forms and 1 unclassified strain, and in 2 cases pol/env sequences classified strains as subtype D whereas gag phylogeny classified them as subtype A. In 10 cases only 1 fragment was available: 4 env (2 subtype D, 1 subtype H, and 1 subtype U) and 6 pol (1 subtype A, 1 subtype C, 2 subtype G, and 2 subtype U). Minor mutations associated with viral resistance to antiretroviral drugs were observed in more than 80% of analyzed strains. Our study confirms the extensive HIV-1 diversity found in Central Africa, with more than 70% of strains from Gabon exhibiting discordant clustering in pol and env genomic regions and less than 60% concordance between sequencing and heteroduplex mobility assay genotyping. These findings highlight the fact that Central Africa represents the epicenter for the origin of HIV-1. The strategy of sequencing pol in association with env has proved to be useful for analysis of the recombinant strains. The main advantage of this approach is that it also allows for evaluation of genotypic susceptibility to antiretroviral drugs without the need for supplementary analyses.
Collapse
Affiliation(s)
- Ivona Pandrea
- Laboratoire de Retroviologie, Centre International de Recherches Medicales, Franceville, Gabon
| | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Troonen H, Grey H, Michel G. Multicenter Study of the LCx® HIV RNA Quantitative Assay – a New Competitive Reverse Transcriptase-PCR which Targets pol Genomic Region of HIV-1 for the Measurement of Type B, Non-Type B and Group O HIV-1 RNA. Clin Chem Lab Med 2002; 40:698-704. [PMID: 12241017 DOI: 10.1515/cclm.2002.120] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Performance characteristics of the Abbott LCx HIV RNA Quantitative Assay (LCx HIV) were established in a multicenter study comparing it with the manual (Amplicor v1.5) and automated (Cobas) ultra-sensitive Roche Amplicor HIV-1 Monitor v1.5, the Bayer Quantiplex HIV RNA 3.0 (bDNA v3.0), and the Organon NucliSens HIV QT 2.0 (NucliSens). Within-run precision of LCx HIV assessed in clinical specimens was SD log10 0.210 at approximately 50 copies/ml, and log10 0.133 at approximately 400 copies/ml. Total precision in a reconstituted type B HIV-1 RNA panel was SD log10 0.380 at 100 copies/ml, and SD log10 0.180 at 1000 copies/ml. Type B HIV-1 RNA sensitivity (1 ml input) assessed at a 50%, 75% and 95% detection rate ranged from 29 to 41, 54 to 75 and 94 to 176 copies/ml, respectively. Overall specificity in HIV seronegative individuals was 99.78%. Linear regression indicated close assay correlations and agreements for measurement of type B HIV-1 RNA. Pearson's correlations and (Log10LCx=aLog10x + b) linear regressions were 0.91 (y=0.892 Log10Amplicor + 0.595), 0.93 (y=0.827 Log10Cobas + 0.969), 0.93 (y=0.951 Log10bDNA + 0.550), and 0.79 (y=0.834 Log10NucliSens + 0.911). LCx HIV was least affected by the genetic variability of HIV-1. LCx HIV detected 99% of non-type B HIV-1 group M samples (subtypes A-G), Amplicor v1.5 detected 96%, and bDNA v3.0 detected 99%. The assays detected 10/11, 1/11 and 8/11, respectively of the HIV-1 group O samples. LCx HIV vs. Amplicor/bDNA Spearman's rank correlations for quantification of non-type B HIV-1 RNA were 0.76/0.84 (A), 0.93/0.93 (C), 0.73/0.99 (D), 0.86/0.98 (E), and 0.40/0.83 (group O). LCx HIV assays consistently detect and quantify type B, non-type B and group O HIV-1 RNA.
Collapse
|
20
|
Lyall EG, Blott M, de Ruiter A, Hawkins D, Mercy D, Mitchla Z, Newell ML, O'Shea S, Smith JR, Sunderland J, Webb R, Taylor GP. Guidelines for the management of HIV infection in pregnant women and the prevention of mother-to-child transmission. HIV Med 2001; 2:314-34. [PMID: 11737411 DOI: 10.1046/j.1464-2662.2001.00082.x] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIMS OF THE GUIDELINES: These guidelines, drawn up by a multidisciplinary group of clinicians and lay workers active in the management of pregnant women infected with HIV, aim to give up-to-date information on interventions to reduce the risk of mother to child transmission of the virus. The evidence on the use of interventions to prevent mother to child transmission of HIV has been graded according to the strength of the data as per the definitions of the US Agency for Health Care Policy and Research [1]. Weighted evidence on the use of combination antiretroviral therapy (ART) for the treatment of HIV infection per se is presented in the BHIVA guidelines for adults [2,3]. The highest level evidence (i.e. randomised controlled trials (RCTs) or large, well conducted meta-analyses) is only available for formula feeding, prelabour caesarean section and zidovudine monotherapy. The need to treat mothers for HIV infection has led to the widespread use of ART in pregnancy which in turn results in new questions such as how to deliver when the mother, on therapy, has no detectable plasma viraemia with the most sensitive assays. In addressing many common and/or difficult clinical scenarios in the absence of 'best evidence' the guidelines rely heavily on 'expert opinion'. Recommendations for management are given in the section on clinical scenarios, and summarized in Table 3. An expanded version of these guidelines with an appendix on safety and toxicity data is available on the BHIVA website http://www.bhiva.org. The authors are available to discuss individual cases.
Collapse
Affiliation(s)
- E G Lyall
- Department of Paediatrics, St Mary's Hospital, Imperial College, London, UK.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
de la Rosa R, Leal M, Pineda JA, Dietrich U, Delgado J, Macías J, Rubio A, Sánchez-Quijano A, Lissen E. Low levels of HIV-1 plasma viral load in patients infected with HIV-1 subtype b and advanced immunosuppression. J Infect 2001; 42:4-7. [PMID: 11243746 DOI: 10.1053/jinf.2000.0771] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVES Some HIV-1 infected patients show low levels of viraemia despite having advanced immunosuppression. Cases with falsely undetectable viraemia by conventional PCR have been reported when patients were infected with non-B subtypes. The aim of this study was to investigate whether this immunovirological discordance can be due to the presence of HIV-1 non-B subtypes, and whether a modified PCR procedure can yield different HIV viraemia values in these cases. METHODS Fifteen HIV-infected patients either naive for antiretroviral drugs or under treatment, with HIV plasma viraemia below 1000 copies/mm(3)and CD4+ cell counts lesser than 500 or 300 cells/mm(3), respectively, were included. Serotyping, genotyping and HIV plasmatic viraemia determinations were performed in all individuals. RESULTS In five out of six treatment-naive patients the virus was categorized as non-B subtype by serotyping, although only one case was confirmed by genotyping as HIV-2. Eight out of nine patients under antiretroviral therapy were subtype B carriers by serotyping and confirmed by genotyping. The remaining patient was determined as a subtype A carrier by both procedures. A modified PCR procedure (Amplicor HIV Monitor Test version 1.5) did not yield higher viral load levels than the former version. CONCLUSIONS The presence of HIV-1 subtypes non-B can explain a minority of cases of this immunovirological discordance, but in most of them the reason is still unknown. Likewise, a PCR procedure adapted for detecting HIV-1 non-B subtypes fails to find higher plasma viraemia in patients with such a discordance.
Collapse
Affiliation(s)
- R de la Rosa
- Department of Internal Medicine, Virgen del Rocio University Hospital, Seville, Spain
| | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Young NL, Shaffer N, Chaowanachan T, Chotpitayasunondh T, Vanparapar N, Mock PA, Waranawat N, Chokephaibulkit K, Chuachoowong R, Wasinrapee P, Mastro TD, Simonds RJ. Early diagnosis of HIV-1-infected infants in Thailand using RNA and DNA PCR assays sensitive to non-B subtypes. J Acquir Immune Defic Syndr 2000; 24:401-7. [PMID: 11035610 DOI: 10.1097/00126334-200008150-00001] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To evaluate the sensitivity and specificity of RNA and DNA polymerase chain reaction (PCR) for early diagnosis of perinatal HIV-1 infection and to investigate early viral dynamics in infected infants. DESIGN A cohort study of 395 non-breastfed infants born to HIV-infected mothers in a randomized clinical trial of short-course antenatal zidovudine. METHODS Infant venous blood specimens collected at birth, 2 months, and 6 months of age were tested by qualitative DNA and quantitative RNA PCR (Roche Amplicor). To determine sensitivity and specificity of DNA and RNA PCR, results were compared with later DNA PCR results and to antibody results at 18 months. The HIV-1 subtype of the mother's infection was determined by peptide serotyping. RESULTS In the study, 92% of mothers were infected with subtype E. DNA PCR sensitivity was 38% (20 of 53) at birth, and 100% at 2 months (53 of 53) and 6 months (47 of 47). RNA PCR sensitivity was 47% (25 of 53) at birth and 100% (53 of 53) at 2 months. All samples that tested DNA-positive tested RNA-positive. Specificity was 100% for both DNA and RNA testing at all timepoints. For infected infants, the median viral load of RNA-positive specimens was 407,000 copies/ml (5.6 log10) at birth, 3, 700,000 copies/ml (6.6 log10) at 2 months, and 1,700,000 copies/ml (6.2 log10) at 6 months. Infant RNA levels at 2 and 6 months did not differ by maternal zidovudine exposure, or RNA level at birth. CONCLUSION This RNA PCR assay performed well for diagnosing perinatal HIV subtype E infection, detecting nearly half of infected infants at birth, and 100% at 2 and 6 months, with 100% specificity. Infected infant viral RNA levels were very high at 2 and 6 months, and were unaffected by maternal zidovudine treatment.
Collapse
Affiliation(s)
- N L Young
- HIV/AIDS Collaboration, Nonthaburi, Thailand.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Early Diagnosis of HIV-1–Infected Infants in Thailand Using RNA and DNA PCR Assays Sensitive to Non-B Subtypes. J Acquir Immune Defic Syndr 2000. [DOI: 10.1097/00042560-200008150-00001] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
24
|
O'Shea S, Chrystie I, Cranston R, Mullen J, Corbett K, Murphy G, Parry JV, De Ruiter A, Banatvala J. Problems in the interpretation of HIV-1 viral load assays using commercial reagents. J Med Virol 2000; 61:187-94. [PMID: 10797373 DOI: 10.1002/(sici)1096-9071(200006)61:2<187::aid-jmv3>3.0.co;2-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
During routine monitoring of human immunodeficiency virus (HIV) viral load, two problems arose. First, a number of patients, the majority being African, were found to have low viral loads by the Chiron branched-chain DNA assay in conjunction with low CD4(+) cell numbers. In order to determine whether this was due to failure of the branched-chain DNA assay to detect non-B subtypes of HIV, selected samples were subtyped and HIV RNA quantified by branched-chain DNA, NASBA, and the Roche Monitor RT-PCR assay. Twenty-eight (97%) of 29 Africans were infected with a non-B subtype of HIV and 15 (93.7%) of 16 non-Africans with subtype B. Twenty-three samples had a low viral load by branched-chain DNA, which was confirmed by the NASBA and RT-PCR assays. All three assays detected B and non-B subtypes with similar efficiency; NASBA failed to detect HIV RNA in a small number of non-B samples. Discrepancies between viral load and CD4(+) cell numbers did not appear therefore to be related to subtype. Second, while quantification of HIV RNA was being conducted using version 2 of the branched-chain DNA assay (lower detection limit 500 HIV RNA copies/ml) the manufacturers had developed a more sensitive assay and a comparative evaluation was therefore conducted. In approximately 30% of samples the viral load was up to 10 times higher with the more sensitive assay. These experiences emphasise the importance of close collaboration between the clinic and the laboratory.
Collapse
Affiliation(s)
- S O'Shea
- Department of Virology, Guy's and St. Thomas' Hospital Trust, London, United Kingdom. o'
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Jagodzinski LL, Wiggins DL, McManis JL, Emery S, Overbaugh J, Robb M, Bodrug S, Michael NL. Use of calibrated viral load standards for group M subtypes of human immunodeficiency virus type 1 to assess the performance of viral RNA quantitation tests. J Clin Microbiol 2000; 38:1247-9. [PMID: 10699033 PMCID: PMC86389 DOI: 10.1128/jcm.38.3.1247-1249.2000] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Optimal management of human immunodeficiency virus type 1 (HIV-1) disease requires accurate quantitation of viral RNA concentrations in plasma. Evidence for increasing geographic intermixing of HIV-1 subtypes makes equivalent quantitation of all subtypes essential. The performances of six quantitative viral RNA tests are described, for the first time, with calibrated viral isolates of diverse subtypes.
Collapse
Affiliation(s)
- L L Jagodzinski
- Henry M. Jackson Foundation, Walter Reed Army Institute of Research, Rockville, Maryland 20850, USA.
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Couturier E, Damond F, Roques P, Fleury H, Barin F, Brunet JB, Brun-Vézinet F, Simon F. HIV-1 diversity in France, 1996-1998. The AC 11 laboratory network. AIDS 2000; 14:289-96. [PMID: 10716505 DOI: 10.1097/00002030-200002180-00011] [Citation(s) in RCA: 85] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To study the distribution of HIV-1 subtypes in France and to describe the characteristics of patients infected with non-B subtypes. METHODS All adults who tested HIV-1 positive on Western blot for the first time in one of the participating laboratories between September 1996 and March 1998 were eligible, whether or not they had been diagnosed previously elsewhere. Data on age, sex, country of birth, HIV-transmission group, dates of the last negative and first positive HIV test and clinical stage were collected. Serotyping was performed with a peptide subtype-specific enzyme immunoassay on each plasma sample and genotyping with heteroduplex mobility assay on each non-B serotype-infected patient. Patients characteristics were compared in B and non-B subtypes. RESULTS Of the 2168 HIV-positive patients included by 32 laboratories, subtype,results were available for 2042. Among those, 73.4% were men, 12.2% born in sub-Saharan Africa, 41.5% infected through heterosexual contact and 67.6% in CDC stage A. Among the 2042 patients, 1 725 (84.5%) were infected with B subtype. Among the 317 non-B subtypes, subtype A was predominant (66.9%); all other subtypes (C, D, E, F, G, H, O) were present. Factors independently associated with a non-B subtype were to be included in the Paris area [adjusted odds ratio (aOR), 1.6; 95% confidence interval (CI), 1.1-2.3], to be born in sub-Saharan Africa (aOR, 26.0; 95% CI, 17.5-37.8) and to be infected through heterosexual contact (aOR, 4.2; 95% CI, 2.8-6.4). CONCLUSIONS In France, although B subtype is still predominant, all non-B subtypes are now present. The diversity of HIV strains may affect diagnostic tests and clinical practice, especially viral load measurements. Moreover, the decreased susceptibility of non-B subtypes to antiretroviral drugs emphasizes the importance of surveillance of HIV diversity.
Collapse
Affiliation(s)
- E Couturier
- European Centre for the Epidemiological Monitoring of AIDS, Hôpital National de Saint-Maurice, France
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Bürgisser P, Vernazza P, Flepp M, Böni J, Tomasik Z, Hummel U, Pantaleo G, Schüpbach J. Performance of five different assays for the quantification of viral load in persons infected with various subtypes of HIV-1. Swiss HIV Cohort Study. J Acquir Immune Defic Syndr 2000; 23:138-44. [PMID: 10737428 DOI: 10.1097/00126334-200002010-00005] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Five methods for the assessment of plasma viral load (VL) were evaluated in 103 seropositive patients infected with various subtypes of HIV-1. The methods included three RNA-based assays (Amplicor Monitor 1.5, Quantiplex version 2.0, NucliSens), one ultrasensitive reverse transcriptase (PERT) assay and one "boosted" p24 antigen (Ag) enzyme immunoassay (EIA). Subtyping was based on sequencing in env. The sensitivities were, in decreasing order, Amplicor > PERT > p24 Ag > NucliSens > Quantiplex. The low sensitivity of NucliSens was related to the missing of several non-B (A, E, F, G) or recombinant strains, whereas that of Quantiplex did not depend on subtype. In the 1 group O sample and 4 group M samples, only PERT assay or p24Ag EIA produced a positive result. In the quantitative range, correlation was best between Amplicor and Quantiplex (r = 0.8848), fair between Amplicor and NucliSens (r = 0.7064) or PERT assay (r = 0.7266), lowest between Amplicor and p24Ag EIA (r = 0.3989). Amplicor underestimated VL in 1 subtype E sample. Thus, Amplicor performed best in terms of sensitivity (compared with all other assays) and accuracy (compared with NucliSens, PERT assay, and p24Ag) for non-B subtypes in group M samples. PERT assay appears useful for VL assessment in infections by group O or other highly divergent viruses.
Collapse
Affiliation(s)
- P Bürgisser
- Division of Immunology and Allergy, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland.
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Bürgisser P, Vernazza P, Flepp M, Böni J, Tomasik Z, Hummel U, Pantaleo G, Schüpbach J. Performance of Five Different Assays for the Quantification of Viral Load in Persons Infected With Various Subtypes of HIV-1. J Acquir Immune Defic Syndr 2000. [DOI: 10.1097/00042560-200002010-00005] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|