1
|
Assessment of the reliability (repeatability) of corneal thickness measurements in soft contact lens wearers using a non-contact specular microscope. Cont Lens Anterior Eye 2021; 45:101491. [PMID: 34340929 DOI: 10.1016/j.clae.2021.101491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 07/08/2021] [Accepted: 07/16/2021] [Indexed: 11/20/2022]
Abstract
PURPOSE To assess variability across 3 measures of central corneal thickness (CCT) obtained with a non-contact specular microscope and taken over a few minutes from habitual soft contact lens wearers. METHODS One eye from 200 healthy adults (with an average age of 21 y, half of whom had a 3.5 ± 2.1 year history of successful daily wear of soft contact lenses while the control group had nominally normal eyes) were assessed using the auto-focus Topcon 2000P instrument to obtain an image of the endothelium and CCT. RESULTS The individual CCT values encountered in the 200 subjects ranged from 0.449 mm to 0.591 mm, with the average of 3 measures ranging from 0.459 to 0.591 mm in the control group and between 0.449 and 0.585 mm for the SCL wearers. The group mean CCT values were the same for both groups (at 0.524 mm), but the group mean SD value was marginally higher (at 0.028 mm) for the SCL group as compared to controls (SD = 0.026 mm). The normalized intra-subject variability (as the group-mean coefficient of variation, COV value) was 0.843 ± 0.401 for the control group and higher at 1.08 ± 0.546 for the SCL group (p < 0.001). CONCLUSIONS Repeat measures of central corneal thickness, using a non-contact specular microscope, is very similar to those taken on age-matched non-contact lens wearers. These results may not equally apply to similar pachymetry measures in patients wearing RGP lenses or for older patients wearing soft contact lenses.
Collapse
|
2
|
Barnett M, Courey C, Fadel D, Lee K, Michaud L, Montani G, van der Worp E, Vincent SJ, Walker M, Bilkhu P, Morgan PB. CLEAR - Scleral lenses. Cont Lens Anterior Eye 2021; 44:270-288. [PMID: 33775380 DOI: 10.1016/j.clae.2021.02.001] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 02/01/2021] [Indexed: 12/25/2022]
Abstract
Scleral lenses were the first type of contact lens, developed in the late nineteenth century to restore vision and protect the ocular surface. With the advent of rigid corneal lenses in the middle of the twentieth century and soft lenses in the 1970's, the use of scleral lenses diminished; in recent times there has been a resurgence in their use driven by advances in manufacturing and ocular imaging technology. Scleral lenses are often the only viable form of contact lens wear across a range of clinical indications and can potentially delay the need for corneal surgery. This report provides a brief historical review of scleral lenses and a detailed account of contemporary scleral lens practice including common indications and recommended terminology. Recent research on ocular surface shape is presented, in addition to a comprehensive account of modern scleral lens fitting and on-eye evaluation. A range of optical and physiological challenges associated with scleral lenses are presented, including options for the clinical management of a range of ocular conditions. Future applications which take advantage of the stability of scleral lenses are also discussed. In summary, this report presents evidence-based recommendations to optimise patient outcomes in modern scleral lens practice.
Collapse
Affiliation(s)
- Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, United States.
| | | | | | - Karen Lee
- University of Houston, College of Optometry, Houston, TX, United States
| | | | - Giancarlo Montani
- Università del Salento, Dipartimento di Matematica e Fisica CERCA, Lecce, Italy
| | - Eef van der Worp
- Eye-Contact-Lens Research & Education, Amsterdam, NL, Netherlands
| | - Stephen J Vincent
- Queensland University of Technology (QUT), Centre for Vision and Eye Research, School of Optometry and Vision Science, Contact Lens and Visual Optics Laboratory, Brisbane, Australia
| | - Maria Walker
- University of Houston, College of Optometry, Houston, TX, United States
| | - Paramdeep Bilkhu
- School of Optometry & Vision Science, Aston University, Birmingham, United Kingdom
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, Manchester, United Kingdom
| |
Collapse
|
3
|
The use of contact lens telescopic systems in low vision rehabilitation. Cont Lens Anterior Eye 2017; 40:131-142. [DOI: 10.1016/j.clae.2017.03.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2016] [Revised: 02/13/2017] [Accepted: 03/10/2017] [Indexed: 11/23/2022]
|
4
|
Identifying relationships between tomography-derived corneal thickness, curvature, and diameter and in vivo confocal microscopic assessment of the endothelium in healthy corneas of young adults. Eye (Lond) 2008; 23:270-8. [PMID: 18259207 DOI: 10.1038/sj.eye.6703091] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Despite the importance of a healthy endothelial layer in anterior segment surgery, the possible influence of corneal parameters on endothelial cell density (ECD) has largely been ignored in the young adult eye. This study investigated the possible associations between corneal tomographic parameters and ECD values in young adults. METHODS Subjects aged 21-30 years, with normal corneas were recruited. Mean ECD, mean cell area (MCA), coefficient of variation for cell area (COVA), and proportion of hexagonal cells were derived by in vivo confocal microscopy. The Orbscan II system was used to measure corneal parameters including: thickness, horizontal corneal diameter, corneal curvature, anterior and posterior elevation, and eccentricity. RESULTS Sixty-two subjects (42 female, 20 male) were included (mean age 25+/-3 years). Overall mean ECD was 3169+/-309 cells/mm(2) with no differences between genders. Mean percentage of hexagonality was 53+/-5%, male subjects (55%) had a higher percentage of hexagonal cells than female subjects (51%) (P=0.02). Central corneal thickness (CCT) was 529+/-43 microm. Central ECD was significantly correlated with CCT (Pearson's r=0.26, P=0.04). However, horizontal corneal diameter (r=0.19, P=0.14), anterior corneal curvature (r=-0.07, P=0.6), and posterior corneal curvature (r=-0.07, P=0.6) were not correlated with ECD or percentage of hexagonality. There was no statistically significant association between anterior chamber depth (3.6+/-0.3 mm) and ECD (r=0.15, P=0.3). CONCLUSION Corneal thickness is related to ECD in normal young adult eye, with lower ECD values identified in thinner corneas; however, corneal diameter and corneal curvature do not have a significant correlation with ECD.
Collapse
|
5
|
Tahzib NG, Nuijts RM, Wu WY, Budo CJ. Long-term Study of Artisan Phakic Intraocular Lens Implantation for the Correction of Moderate to High Myopia. Ophthalmology 2007; 114:1133-42. [PMID: 17275909 DOI: 10.1016/j.ophtha.2006.09.029] [Citation(s) in RCA: 119] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2006] [Revised: 09/15/2006] [Accepted: 09/15/2006] [Indexed: 12/13/2022] Open
Abstract
PURPOSE To determine the long-term performance of the Artisan phakic intraocular lens (PIOL) for the correction of myopia. DESIGN Long-term (10 years) retrospective follow-up study. PARTICIPANTS Eighty-nine eyes of 49 patients who underwent Artisan PIOL implantation for the correction of myopia. METHODS Comparisons were made between preoperative clinical data and the clinical data at 1, 6, and 10 years after surgery. MAIN OUTCOME MEASURES Refractive stability, refractive predictability, safety, efficacy, best-corrected visual acuity (BCVA), uncorrected visual acuity (UCVA), intraocular pressure, intraoperative problems, corneal endothelial cell density, corneal endothelial cell loss, and glare levels were evaluated. RESULTS The mean spherical equivalent (SE) after 10 years was -0.70+/-1.00 diopters (D; range, -4.00 to 2.00 D), with no significant change in mean SE between 1, 6, and 10 years. At 10 years, 68.8% of all eyes were within 1.0 D of the intended correction. At 10 years, 31.2% (n = 24) gained 1 or more Snellen lines of BCVA and 2.6% (n = 2) lost more than 2 Snellen lines of BCVA; 93.3% reached a BCVA of 20/40 or better, and 82.0% reached a UCVA of 20/40 or better. The mean intraocular pressure remained stable and was 15.5+/-3.5 mmHg (range, 7-25 mmHg) at 10 years. The mean endothelial cell loss was -8.86+/-16.01% (range, -51.69% to 34.43%) at 10 years. CONCLUSIONS Long-term results demonstrate that the implantation of an Artisan PIOL for the correction of moderate to high myopia is a stable, predictable, and safe method when strict inclusion criteria for surgery are applied. There was no significant loss of corneal endothelial cells and no reports of long-term glare.
Collapse
Affiliation(s)
- Nayyirih G Tahzib
- Department of Ophthalmology, Academic Hospital Maastricht, Maastricht, The Netherlands.
| | | | | | | |
Collapse
|
6
|
Müller A, Craig JP, Grupcheva CN, McGhee CNJ. The effects of corneal parameters on the assessment of endothelial cell density in the elderly eye. Br J Ophthalmol 2004; 88:325-30. [PMID: 14977761 PMCID: PMC1772027 DOI: 10.1136/bjo.2003.019315] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/13/2003] [Indexed: 11/04/2022]
Abstract
BACKGROUND The possible impact of corneal thickness, curvature, and size on the measurement of endothelial cell density (ECD) has largely been ignored in the normal eye. The aim of this study was to investigate the possible impact of the main corneal parameters on the analysis of ECD values at the central, superior, and temporal parts of the corneal surface. METHODS All 75 participants (52 females, 23 males) were assessed as part of a pre-cataract surgery investigation. The mean age was 75.7 (SD 10.9) years. Confocal microscopy was used to measure ECD and the percentage of six sided cells at the central, superior, and temporal parts of the cornea. The Orbscan II topography system was used to measure corneal thickness, topography, and horizontal corneal diameter. RESULTS The mean central ECD measured was 2488 (SD 301) cells/mm(2), compared with 2525 (SD 505) cells/mm(2) in the temporal cornea and 2639 (SD 398) cells/mm(2) in the superior cornea. The regional differences in ECD were not significant (p>0.14). The central ECD was significantly correlated to the central (mean 0.593 (SD 0.039) mm, p = 0.021) as well as the temporal (0.628 (SD 0.039) mm, p<0.001) and the superior corneal thickness (SD 0.644 (SD 0.048) mm, p = 0.018). The mean corneal curvature at the centre (7.7 (SD 0.34) mm, p = 0.002) as well as 3 and 5 mm from the apex was significantly related to ECD (p = 0.008 and p = 0.009, respectively). CONCLUSIONS The study suggests that in an older population, lower ECD values would be expected in thinner and/or steeper corneas.
Collapse
Affiliation(s)
- A Müller
- Department of Ophthalmology, The University of Auckland, Auckland, New Zealand.
| | | | | | | |
Collapse
|
7
|
Pop M, Payette Y. Initial results of endothelial cell counts after Artisan Lens for Phakic Eyes. Ophthalmology 2004; 111:309-17. [PMID: 15019381 DOI: 10.1016/j.ophtha.2003.05.025] [Citation(s) in RCA: 96] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2002] [Accepted: 05/23/2003] [Indexed: 11/15/2022] Open
Abstract
PURPOSE To evaluate the endothelial cell count change in eyes implanted with the iris-claw phakic Artisan lens for treatment of moderate to high myopia. DESIGN Prospective, multicenter clinical trial. PARTICIPANTS The first 765 eyes enrolled at 25 North American sites in the United States Food and Drug Administration Ophtec clinical trial of the myopic Artisan IOL. Outcome analyses of endothelial cell count measurements were based on those obtained before surgery and at 6, 12, and 24 months after surgery performed between October 1998 and December 2001. SETTING Multiple private and university practices. METHODS Percentage change in endothelial cell count from baseline to 6, 12, and 24 months were analyzed using specular microscopy. Upper limit of detecting endothelial cell density change was estimated using 3 repeated counts at preoperative and postoperative time frames. MAIN OUTCOME MEASURES Percentage change in endothelial cell loss. RESULTS The mean preoperative endothelial cell count was 2631+/-442 cells/mm(2). Percentage change from baseline at 6, 12, and 24 months was -0.09%+/-16.39%, -0.87%+/-16.35%, and -0.78%+/-17.41%. No statistically significative postoperative endothelial cell loss was found. The endothelial cell loss rate was higher among patients who wore spectacles before surgery and was correlated negatively with preoperative endothelial cell density (P<0.001). No relationships were noted between endothelial cell loss and either patient age or implant power. A 4.1% repeatability of measurements was found based on the average of 3 repeated counts, whereas single cell count estimates were associated with a 23% accuracy in detecting endothelial cell density change. In a worst-case scenario, adjusting for measurement accuracy, 9% of all eyes were at higher risk of a 10% loss of cell density at 12 months after surgery, although eyes at higher risk were found to have high preoperative endothelial cell counts (P<0.0001). CONCLUSIONS The Artisan iris-claw phakic intraocular lens did not result in significant loss of endothelial cell density up to 2 years after implantation of the myopic Artisan phakic lens.
Collapse
Affiliation(s)
- Mihai Pop
- Michel Pop Clinics, Montreal, Canada.
| | | |
Collapse
|
8
|
Abstract
PURPOSE The management of some ocular surface diseases may be enhanced by the overnight wear of a rigid gas-permeable (RGP) scleral contact lens (ScCL). There is little information of the hypoxic effect of extended RGP ScCL wear. The authors measured the corneal swelling after overnight wear of a rigid gas permeable scleral contact lens in normal subjects. METHODS Four subjects wore an RGP ScCL overnight in 1 eye only on 4 occasions. The following morning the lens was removed immediately before optical pachymetry, and the corneal thicknesses of both eyes were measured by a masked observer. On another four occasions optical pachymetry was performed, but the lens was not worn the previous night. For each subject the lens was of the same thickness. Specular microscopy was used to estimate endothelial cell density. RESULTS There were no adverse effects, and subjects reported no difficulties in handling the lenses. Overnight wear of ScCL induced a variable amount of corneal swelling among subjects from 4.9% to 17.5%. The overnight swelling correlated strongly with endothelial cell density. CONCLUSIONS Overnight wear of ScCL caused an increased degree of corneal swelling compared with daytime wear. This degree of swelling should not rule out overnight therapeutic ScCL wear if the disease process is deemed to be more damaging than the hypoxic effect of an RGP ScCL worn overnight. However, when used for refractive correction, they should not be left in overnight.
Collapse
Affiliation(s)
- Guy T Smith
- Moorfields Eye Hospital, 162 City Road, London EC1V 2PD, England, UK
| | | | | |
Collapse
|
9
|
Sanchis-Gimeno JA, Lleó A, Alonso L, Rahhal MS, Martínez-Soriano F. Differences in corneal anatomy in a pair of monozygotic twins due to continuous contact lens wear. Cornea 2003; 22:243-5. [PMID: 12658091 DOI: 10.1097/00003226-200304000-00012] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE To study the differences in the corneal anatomy in a pair of 31-year-old monozygotic female twins, one of whom has been a contact lens wearer for the past 15 years and the other is a nonwearer. METHODS We analyzed the corneal thickness and the corneal endothelial cell density of the monozygotic twins and of two age-matched control groups, one made up of non-contact lens wearers (35 eyes of 35 patients; mean age, 29.32 +/- 2.83 years) and the other made up of soft contact lens wearers (30 eyes of 30 patients; mean age, 33.08 +/- 3.72 years; mean duration of contact lens use, 10.62 +/- 4.32 years). Five corneal thickness measurements were carried out with the Orbscan Topography System II. Three consecutive measurements of the corneal endothelial cell density were carried out with the Topcon SP-2000P noncontact specular microscope. RESULTS Lower central corneal endothelial cell densities were found in both eyes of the monozygotic contact lens-wearing twin. The greater corneal thickness was shown at superonasal cornea except in the right cornea of the monozygotic contact lens twin. Moreover, significant differences in corneal thickness values were found between the monozygotic twins. CONCLUSIONS The differences between the monozygotic twins seem to confirm that daily use of soft contact lenses can modify normal corneal anatomy.
Collapse
Affiliation(s)
- Juan A Sanchis-Gimeno
- Department of Anatomy and Human Embryology, University of Valencia, Faculty of Medicine, Spain.
| | | | | | | | | |
Collapse
|
10
|
Metha AB, Crane AM, Rylander HG, Thomsen SL, Albrecht DG. Maintaining the cornea and the general physiological environment in visual neurophysiology experiments. J Neurosci Methods 2001; 109:153-66. [PMID: 11513950 DOI: 10.1016/s0165-0270(01)00409-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Neurophysiologists have been investigating the responses of neurons in the visual system for the past half-century using monkeys and cats that are anesthetized and paralyzed, with the non-blinking eyelids open for prolonged periods of time. Impermeable plastic contact lenses have been used to prevent dehydration of the corneal epithelium, which would otherwise occur in minutes. Unfortunately, such lenses rapidly introduce a variety of abnormal states that lead to clouding of the cornea, degradation of the retinal image, and premature termination of the experiment. To extend the viability of such preparations, a new protocol for maintenance of corneal health has been developed. The protocol uses rigid gas permeable contact lenses designed to maximize gas transmission, rigorous sterile methods, and a variety of methods for sustaining and monitoring the overall physiology of the animal. The effectiveness of the protocol was evaluated clinically by ophthalmoscopy before, during, and after the experiments, which lasted 8-10 days. Histopathology and quantitative histology were performed on the corneas following the experiment. Our observations showed that this protocol permits continuous contact lens wear without adversely affecting the corneas. Thus, it is possible to collect data 24 h each day, for the entire duration of the experiment.
Collapse
Affiliation(s)
- A B Metha
- Department of Optometry and Vision Sciences, The University of Melbourne, Victoria 3053, Carlton, Australia
| | | | | | | | | |
Collapse
|
11
|
Doughty MJ, Müller A, Zaman ML. Assessment of the reliability of human corneal endothelial cell-density estimates using a noncontact specular microscope. Cornea 2000; 19:148-58. [PMID: 10746445 DOI: 10.1097/00003226-200003000-00006] [Citation(s) in RCA: 93] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE We sought to determine the variance in endothelial cell density (ECD) estimates for human corneal endothelia. METHODS Noncontact specular micrographs were obtained from white subjects without any history of contact lens wear, or major eye disease or surgery; subjects were within four age groups (children, young adults, older adults, senior citizens). The endothelial image was scanned, and the areas from > or =75 cells measured from an overlay by planimetry. The cell-area values were used to calculate the ECD repeatedly so that the intra- and intersubject variation in an average ECD estimate could be made by using different numbers of cells (5, 10, 15, etc.). RESULTS An average ECD of 3,519 cells/mm2 (range, 2,598-5,312 cells/mm2) was obtained of counts of 75 cells/ endothelium from individuals aged 6-83 years. Average ECD estimates in each age group were 4,124, 3,457, 3,360, and 3,113 cells/mm2, respectively. Analysis of intersubject variance revealed that ECD estimates would be expected to be no better than +/-10% if only 25 cells were measured per endothelium, but approach +/-2% if 75 cells are measured. CONCLUSION In assessing the corneal endothelium by noncontact specular microscopy, cell count should be given, and this should be > or =75/ endothelium for an expected variance to be at a level close to that recommended for monitoring age-, stress-, or surgery-related changes.
Collapse
Affiliation(s)
- M J Doughty
- Department of Vision Sciences, Glasgow-Caledonian University, Scotland.
| | | | | |
Collapse
|
12
|
Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000; 44:367-408. [PMID: 10734239 DOI: 10.1016/s0039-6257(00)00110-7] [Citation(s) in RCA: 939] [Impact Index Per Article: 39.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
We determined the "normal" central corneal thickness (CCT) value in human corneas based on reported literature values for within-study average CCT values, and used this as a reference to assess the reported impact of physiological variables (especially age and diurnal effects), contact lens wear, pharmaceuticals, ocular disease, and ophthalmic surgery on CCT. With the expected CCT and its variance defined, it should be possible to determine the potential impact of differences in CCT in intraocular pressure (IOP) assessments, especially by applanation tonometry, using a meta-analysis approach. Some 600 sets of CCT data were identified from the worldwide literature over the period of 1968 through mid-1999, of which 134 included IOP measures as well. The within-study average CCT values and reported variance (SD) was noted along with the number of eyes and any special characteristics, including probable ethnic origin of the study subjects. Various sets of data were subjected to statistical analyses. From 300 data sets from eyes designated as normal, the group-averaged CCT was 0.534 mm. From 230 data sets where interindividual variance was reported, the group-averaged CCT was 0.536 mm (median 0.536 mm; average SD of 0. 031 mm, average coefficient of variation = 5.8%). Overall, studies using slit-lamp-based pachometry have reported marginally lower CCT values (average 0.530 mm, average SD 0.029 mm) compared to ultrasound-based studies (average 0.544, average SD 0.034 mm), which perhaps reflects the type of individual studied (non-surgical vs. pre-surgical patients) rather than the technique itself. A slight chronological increase in reported average CCT values (approximately 0.006 mm/decade) was evident, but a substantial chronological increase was evident for ultrasound pachometry studies (approximately 0.015 mm/decade). Within the meta-analysis-generated average and variance, age had no obvious impact on CCT measures for *whites, although an age-related decline in CCT is evident for non-whites. Any diurnal effects are likely concealed within the expected variance in CCT. Contact lens wear and pharmaceuticals generally produced changes in CCT that were well within the expected variance in CCT. Of the ocular diseases, only those associated with collagen disorders (including keratoconus) or endothelial-based corneal dystrophies (e.g., Fuchs) were likely to result in decreases or increases, respectively, of CCT beyond the normal variance. Routine contact lens wear and diseases such as diabetes seem unlikely to produce changes in CCT of a magnitude that would justify pachometry as a monitoring method beyond routine slit-lamp evaluation. Increases in CCT beyond the expected variance were reported after a range of intraocular surgeries (cataract operations, penetrating keratoplasty), whereas photorefractive surgery produces a measurable decrease in CCT. A meta-analysis of possible association between CCT and IOP measures of 133 data sets, regardless of the type of eyes assessed, revealed a statistically significant correlation; a 10% difference in CCT would result in a 3. 4 +/- 0.9 mm Hg difference in IOP (P </= 0.001, r = 0.419). The observed phenomenon was much smaller for eyes designated as healthy (1.1 +/- 0.6 mm Hg for a 10% difference in CCT, P = 0.023, r = 0. 331). For eyes with chronic diseases, the change was 2.5 +/- 1.1 mm Hg for a 10% difference in CCT (P = 0.005, r = 0.450), whereas a substantial but highly variable association was seen for eyes with acute onset disease (approximately 10.0 +/- 3.1 mm Hg for a 10% difference in CCT, P = 0.004, r = 0.623). Based on the meta-analysis, normal CCT in white adults would be expected to be within +/-11.6% (+/-2 SD) of 0.535 mm, i.e., 0.473-0.597 mm (95% CI, 0.474-0.596). The impact of CCT on applanation tonometry of healthy eyes is unlikely to achieve clinical significance, but for corneas of eyes with chronic disease, pachometry should be performed if the tonometry reveals IOP readi
Collapse
Affiliation(s)
- M J Doughty
- Department of Vision Sciences, Glasgow-Caledonian University, Glasgow, United Kingdom
| | | |
Collapse
|