1
|
Lievens C, Pucker AD, Rayborn E, Kannarr S, Bickle K, Hogan C, Franklin QX, Christensen M. Refitting contact lens dropouts into a modern daily disposable contact lens. Ophthalmic Physiol Opt 2024; 44:686-692. [PMID: 38433496 DOI: 10.1111/opo.13299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 02/15/2024] [Accepted: 02/21/2024] [Indexed: 03/05/2024]
Abstract
PURPOSE To determine the number of previous contact lens (CL) wearers who could be comfortably refitted into delefilcon A (DAILIES TOTAL1®) CLs. METHODS This was a 6-month, three-visit study that recruited subjects who discontinued CLs within the past 2 years because of discomfort or dryness symptoms. Subjects were required to have Standard Patient Evaluation of Eye Dryness (SPEED) questionnaire scores ≤3 and to be able to wear spherical study CLs. Subjects were asked to complete a ±50 comfort visual analogue scale (VAS) at 1 month and a Likert questionnaire after 1 and 6 months of CL wear to understand the subjects' CL experience. RESULTS All 60 subjects who were fitted with the study CLs were still wearing them after 1 month, while one subject had dropped out by 6 months. Subjects had a median (interquartile range) age of 24.0 (7.0) years (71.7% female). They reported a median VAS score of 44.0 (8.0) units at the 1-month visit, with all reporting a comfortable score. At the 1-month/6-month visits, 98.3%/93.2%, 86.5%/78.0% and 93.2%/91.5% of subjects responded that they were very satisfied or satisfied with their vision, their end-of-day CL comfort and overall CL comfort, respectively. The same subjects responded that they were very likely or likely to continue to wear the study CLs at 1 (89.6%) and 6 months (80.7%) and to recommend the study CLs to a friend at 1 (98.3%) and 6 months (93.2%). CONCLUSIONS The results suggest that when encountering a CL dropout, a practitioner could educate a patient about trying an alternative CL and consider delefilcon A lenses as an option.
Collapse
Affiliation(s)
- Chris Lievens
- Southern College of Optometry, Memphis, Tennessee, USA
| | - Andrew D Pucker
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Elyse Rayborn
- Southern College of Optometry, Memphis, Tennessee, USA
| | | | | | | | - Quentin X Franklin
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | | |
Collapse
|
2
|
Xiong R, Wang W, Tang X, He M, Hu Y, Zhang J, Du B, Jiang Y, Zhu Z, Chen Y, Zhang S, Kong X, Wei R, Yang X, He M. Myopia Control Effect of Repeated Low-Level Red-Light Therapy Combined with Orthokeratology: A Multicenter Randomized Controlled Trial. Ophthalmology 2024:S0161-6420(24)00308-7. [PMID: 38763303 DOI: 10.1016/j.ophtha.2024.05.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/10/2024] [Accepted: 05/13/2024] [Indexed: 05/21/2024] Open
Abstract
PURPOSE To investigate the efficacy and safety of repeated low-level red-light(RLRL) therapy combined with orthokeratology(Ortho-k) among the children who, despite undergoing Ortho-k treatment, exhibited an axial elongation of at least 0.50mm over 1 year. DESIGN Multicenter, randomized, parallel-group, single-blind clinical trial (ClinicaTrials.gov,NCT04722874). PARTICIPANTS Eligible children were aged 8-13 years with a cycloplegic spherical equivalent refraction of -1.00 to -5.00 diopters in the initial Ortho-k fitting examination and had annual axial length (AL) elongation ≥ 0.50 mm despite undergoing Ortho-k for 1 year. A total of 48 children were enrolled from March 2021 to January 2022, and the final follow-up was completed in March 2023. METHODS Children were randomly assigned to the RLRL combined with Ortho-k(RCO) or the Ortho-k group in a 2:1 ratio. The Ortho-k group wore Ortho-k at least 8 hours per night, while the RCO group received daily RLRL therapy twice a day for 3 minutes in addition to Ortho-k wearing. MAIN OUTCOME MEASURES The primary outcome was AL change measured at 12 months relative to baseline. The primary analysis was conducted in children who received the assigned intervention and completed at least 1 post-randomization follow-up using the modified intention-to-treat principle. RESULTS A total of 47(97.9%) children were included in the analysis (30 in the RCO group and 17 in the Ortho-k group). The mean axial elongation rate before the trial was 0.60mm/year in the RCO group and 0.61mm/year in the Ortho-k group. After 12 months following the intended intervention, the adjusted mean AL changes were -0.02mm(95% CI, -0.08 to +0.03 mm) in the RCO group and 0.27mm(0.19-0.34 mm) in the Ortho-k group. The adjusted mean difference in AL change was -0.29mm(-0.44 to -0.14mm) between the RCO and Ortho-k groups. The percentage of children achieving an uncorrected visual acuity greater than 20/25 was similar in the RCO (64.3%) and Ortho-k (65.5%) groups (Chi2 test, P=0.937). CONCLUSIONS Combining RLRL therapy with Ortho-k may offer a promising approach to optimize axial elongation control among myopic children. This approach also potentially allows children to achieve satisfactory visual acuity, reducing the daytime dependence on corrective eyewear.
Collapse
Affiliation(s)
- Ruilin Xiong
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China
| | - Wei Wang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China
| | - Xianghua Tang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China
| | - Meinan He
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yin Hu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China
| | - Jian Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China
| | - Bei Du
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Yu Jiang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China; Department of Ophthalmology, the Second Affiliated Hospital, School of Medicine, South China University of Technology, Guangzhou, China
| | - Zhuoting Zhu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China; Center for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia
| | - Yanping Chen
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China
| | - Shiran Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China
| | - Xiangbin Kong
- Ophthalmology, Department of Surgery, The Second People's Hospital of Foshan, Foshan, Guangdong, China.
| | - Ruihua Wei
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China.
| | - Xiao Yang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China.
| | - Mingguang He
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China; School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong; Research Centre for SHARP Vision (RCSV), The Hong Kong Polytechnic University, Kowloon, Hong Kong; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong.
| |
Collapse
|
3
|
Alotaibi S, Papas E, Mobeen R, Ozkan J, Misra SL, Markoulli M. Tear film hTERT and corneal nerve characteristics in dry eye disease. Clin Exp Optom 2024:1-6. [PMID: 38755754 DOI: 10.1080/08164622.2024.2354775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2023] [Accepted: 05/08/2024] [Indexed: 05/18/2024] Open
Abstract
CLINICAL RELEVANCE The behaviour of human telomerase reverse transcriptase (hTERT) in tears reflects its role in maintaining the ocular surface homoeostasis, as it is increased after the initial fitting of contact lenses and post-overnight lid closure. BACKGROUND hTERT has been shown to respond to cellular stress in neurodegenerative diseases and to enhance axonal regeneration after peripheral axotomy in an animal model. This work investigated whether the behaviour of hTERT in the tear film reflects ocular surface inflammation and neuronal changes in the presence of dry eye disease. METHODS Flush tears were collected from 18 participants with dry eye disease (14 females, 4 males, mean age 34.7 ± 5.2 years) and from 18 healthy participants without dry eye disease (8 females, 10 males, mean age 31.9 ± 5.8 years). Dry eye disease status was defined using the TFOS DEWS II diagnostic criteria. hTERT levels in tears were measured using enzyme-linked immunosorbent assays. Confocal images were taken at the level of the subbasal nerve plexus at the central cornea and at the inferior whorl, and the densities of corneal immune cells were evaluated as well as corneal nerve morphology metrics using a fully automated technique (University of Manchester, United Kingdom). RESULTS In participants with dry eye disease, hTERT levels were significantly higher compared to controls (median [interquartile range]: 434 [320-600] ng/ml, and 184 [42-390] ng/ml, respectively, p = 0.01). Increased nerve fibre width at the inferior whorl, was seen in those with dry eyes (0.0219 [0.0214-0.0236] mm/mm compared to controls 0.0217 [0.0207 0.0222] p < 0.001), but no significant differences were found in the density of corneal immune cells. CONCLUSIONS hTERT levels were elevated in participants with dry eye disease, and this was accompanied by increased nerve thickness in the inferior cornea. The hTERT response may reflect the stress induced to the ocular surface and corneal nerves due to having dry eye disease.
Collapse
Affiliation(s)
- Sultan Alotaibi
- Department of Optometry and Vision Science, College of Applied Medical Science, King Saud University, Riyadh, Saudi Arabia
| | - Eric Papas
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Rabia Mobeen
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Jerome Ozkan
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Stuti L Misra
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Maria Markoulli
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
4
|
Valencia-Nieto L, Pinto-Fraga J, Blanco-Vázquez M, Fernández I, López-Miguel A, García-Vázquez C, González-García MJ, Enríquez-de-Salamanca A, Calonge M. Short-Term Efficacy of Ophthalmic Cyclosporine: A 0.1% Cationic Emulsion in Dry Eye Patients Assessed Under Controlled Environment. Ophthalmol Ther 2024; 13:1197-1210. [PMID: 38446281 DOI: 10.1007/s40123-024-00906-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Accepted: 02/05/2024] [Indexed: 03/07/2024] Open
Abstract
INTRODUCTION To evaluate the short-term efficacy of cyclosporine A (CsA)-0.1% cationic emulsion (CE) in patients with dry eye disease (DED) and mitigation of the inflammatory flares triggered by desiccating stress environments. METHODS A single-center non-randomized clinical trial was performed at a tertiary care setting. Twenty patients with DED treated with CsA 0.1% CE were exposed to a normal controlled environment (NCE) (23 °C, 50% relative humidity) and an adverse controlled environment (ACE) (23 °C, 10% relative humidity, 0.43 m/s localized airflow) during baseline and the 1- and 3-month visits. Patients underwent the following evaluations: conjunctival hyperemia and staining, corneal fluorescein staining (CFS) using the Oxford and Cornea and Contact Lens Research Unit (CCLRU) scale, meibomian gland (MG) secretion quality, Dry Eye Questionnaire-5, Symptom Assessment in Dry Eye (SANDE II), and Change in Dry Eye Symptoms Questionnaire. Multivariate models were adjusted for statistical analysis. RESULTS Nineteen women and one man (mean age, 58.9 ± 12.3 years) completed the study. All symptom questionnaires, CFS, conjunctival hyperemia and staining, and MG secretion quality improved (p ≤ 0.003) with 1 month of treatment; improvements were maintained after 3 months (p ≤ 0.02), except for SANDE II (p ≥ 0.07). The CFS worsening (total CCLRU) after baseline ACE exposure (from 8.6 to 10.1) was higher, although not significant (p = 0.64), compared with 1 month (from 5.4 to 5.8) and 3 months (from 5.0 to 5.9) after treatment. CONCLUSION Topical CsA-0.1% CE improved DED signs and symptoms after 1 month of treatment under controlled environmental conditions. Future studies should confirm the benefit of CsA-0.1% CE in desiccating stress environments. TRIAL REGISTRATION ClinicalTrials.gov identifier, NCT04492878.
Collapse
Affiliation(s)
- Laura Valencia-Nieto
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Campus Universitario Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
| | - José Pinto-Fraga
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Campus Universitario Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Marta Blanco-Vázquez
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Campus Universitario Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Itziar Fernández
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Campus Universitario Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Campus Universitario Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain.
| | - Carmen García-Vázquez
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Campus Universitario Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
| | - María J González-García
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Campus Universitario Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - Amalia Enríquez-de-Salamanca
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Campus Universitario Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - Margarita Calonge
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Campus Universitario Miguel Delibes, Paseo de Belén 17, 47011, Valladolid, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|
5
|
Petriček I, Lešin Gaćina D, Tomić M, Bulum T, Bešlić I, Vidas Pauk S. Post-Blink Blur Time-A Simple Test to Detect Dry Eye-Related Visual Disturbances. J Clin Med 2024; 13:2473. [PMID: 38731003 PMCID: PMC11084590 DOI: 10.3390/jcm13092473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 04/18/2024] [Accepted: 04/22/2024] [Indexed: 05/13/2024] Open
Abstract
Background: Dry eye disease (DED) stands out as one of the most common eye conditions encountered in clinical settings. This study aimed to determine the diagnostic ability and feasibility of post-blink blur time (PBBT) in detecting patients with DED symptoms. Methods: The study included 200 subjects, 100 with and 100 without DED symptoms defined by the Schein questionnaire, who underwent assessment of DED signs [visual acuity, PBBT, conjunctival hyperemia, lid-parallel conjunctival folds-LIPCOF, tear film break-up time-TBUT, fluorescein corneal staining, and meibum score]. Results: DED subjects had a lower PBBT than controls (p < 0.001), with subjective (6 (1-45) s vs. 8 (1-70) s) and objective (6 (2-33) s vs. 8 (2-50) s) PBBT measurements being similar between repeats. The correlations between subjective and objective PBBT measurements were significantly positive (R = 0.873, p < 0.001). Subjective PBBT was negatively related to the Schein questionnaire (R = -0.217, p = 0.002), conjunctival hyperemia (R = -0.105, p = 0.035), and corneal staining (R = -0.153, p = 0.031), while positively related to the TBUT (R = 0.382, p < 0.001) and meibum score (R = 0.106, p = 0.033). Logistic regression analysis showed DED symptoms were significantly associated with subjective PBBT (AOR 0.91, p = 0.001), TBUT (AOR 0.79, p < 0.001), meibum score (AOR 0.65, p = 0.008), LIPCOF (AOR 1.18, p = 0.002) and corneal staining (AOR 1.14, p = 0.028). Conclusions: Subjective self-reported PBBT is a reliable and non-invasive screening test for evaluating time-wise changes in visual acuity and detecting a tear film dysfunction.
Collapse
Affiliation(s)
- Igor Petriček
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
- School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Dina Lešin Gaćina
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
| | - Martina Tomić
- Department of Diabetes and Endocrinology, Vuk Vrhovac University Clinic for Diabetes, Endocrinology and Metabolic Diseases, Merkur University Hospital, 10000 Zagreb, Croatia
| | - Tomislav Bulum
- School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
- Department of Diabetes and Endocrinology, Vuk Vrhovac University Clinic for Diabetes, Endocrinology and Metabolic Diseases, Merkur University Hospital, 10000 Zagreb, Croatia
| | - Iva Bešlić
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
| | - Sania Vidas Pauk
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
| |
Collapse
|
6
|
Harthan JS, Than T, Shorter E, Hartwick ATE, Morettin CE, Huecker JB, Johnson SD, Migneco MK, Whiteside M, Olson CK, Alferez CS, van Zyl T, Gordon MO. Natural history of adenoviral conjunctivitis in a US-based population: Viral load, signs, and symptoms. Cont Lens Anterior Eye 2024; 47:102110. [PMID: 38171995 PMCID: PMC10960668 DOI: 10.1016/j.clae.2023.102110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 12/15/2023] [Accepted: 12/18/2023] [Indexed: 01/05/2024]
Abstract
PURPOSE To report the clinical signs, symptoms, and viral clearance in individuals in the United States with adenoviral conjunctivitis (Ad-Cs). METHODS Individuals ≥ 18 years presenting within 4 days of symptoms of Ad-Cs who met eligibility criteria and tested positive with both point-of-care immunoassay antigen and quantitative polymerase chain reaction (qPCR) testing were enrolled. Patient-reported symptoms, clinician-graded signs, and qPCR viral titers were collected at baseline, days 1-2, 4 (days 3-5), 7 (days 6-10), 14 (days 11-17) and 21 (days 18-21). RESULTS There was no detectable viral titers by the day 14 visit in 6/8 patients. By day 21, there was no detectable viral titers in the 7 participants who completed the visit; however, signs and symptoms persisted including: blurry vision (5/7), discomfort (2/7) or redness (1/7). Masked clinicians also noted conjunctival redness (4/7), follicular conjunctivitis (4/7) and bulbar edema (3/7). CONCLUSION Many patient-reported symptoms and clinical signs persist after viral titers are no longer detectable by qPCR. Using clinical signs and symptoms to determine quarantine duration may result in patients being furloughed longer than the time that the patient is infectious.
Collapse
Affiliation(s)
| | - Tammy Than
- Carl Vinson VA Medical Center, United States
| | - Ellen Shorter
- Illinois Eye and Ear Infirmary University of Illinois at Chicago, United States
| | | | | | | | | | | | | | | | | | | | - Mae O Gordon
- Washington University School of Medicine, United States
| |
Collapse
|
7
|
Domínguez-López A, Blanco-Vázquez M, Calderón-García AÁ, García-Vázquez C, González-García MJ, Calonge M, Enríquez-de-Salamanca A. Analysis of the mucosal chemokines CCL28, CXCL14, and CXCL17 in dry eye disease: An in vitro and clinical investigation. Exp Eye Res 2024; 241:109854. [PMID: 38453037 DOI: 10.1016/j.exer.2024.109854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 02/21/2024] [Accepted: 03/04/2024] [Indexed: 03/09/2024]
Abstract
Mucosal chemokines have antimicrobial properties and play an important role in mucosal immunity. However, little is known about their expression on the ocular surface. This study aimed to analyze the expression of the mucosal chemokines CCL28, CXCL14 and CXCL17 in corneal and conjunctival epithelial cells under in vitro dry eye (DE) conditions, and in conjunctival samples from healthy subjects and DE patients. Human corneal epithelial cells (HCE) and immortalized human conjunctival epithelial cells (IM-HConEpiC) were incubated under hyperosmolar (400-500 mOsM) or inflammatory (TNF-α 25 ng/mL) conditions for 6 h and 24 h to measure CCL28, CXCL14, and CXCL17 gene expression by RT-PCR and their secretion by immunobead-based analysis (CCL28, CXCL14) and ELISA (CXCL17). Additionally, twenty-seven DE patients and 13 healthy subjects were included in this study. DE-related questionnaires (OSDI, mSIDEQ and NRS) evaluated symptomatology. Ocular surface integrity was assessed using vital staining. Tactile sensitivity was measured with Cochet-Bonnet esthesiometer, and mechanic and thermal (heat and cold) sensitivity using Belmonte's non-contact esthesiometer. Subbasal nerve plexus and dendritic cell density were analyzed by in vivo confocal microscopy. Conjunctival cells from participants were collected by impression cytology to measure mucosal chemokines gene expression by RT-PCR. Our results showed that HCE and IM-HConEpiC cells increased CCL28, CXCL14, and CXCL17 secretion under hyperosmolar conditions. The gene expression of CCL28 was significantly upregulated in conjunctival samples from DE patients. CCL28 expression correlated positively with symptomatology, corneal staining, heat sensitivity threshold, and dendritic cell density. CXCL14 expression correlated positively with age, ocular pain, conjunctival staining, tactile sensitivity, and image reflectivity. CXCL17 expression correlated positively with corneal staining. These results suggest that corneal and conjunctival epithelial cells could be a source of CCL28, CXCL14, and CXCL17 on the ocular surface and that CCL28 might be involved in DE pathogenesis.
Collapse
Affiliation(s)
| | - Marta Blanco-Vázquez
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
| | | | - Carmen García-Vázquez
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - María J González-García
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Carlos III National Institute of Health, Spain
| | - Margarita Calonge
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; OculoFacial Pain Unit, Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Carlos III National Institute of Health, Spain
| | - Amalia Enríquez-de-Salamanca
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; OculoFacial Pain Unit, Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Carlos III National Institute of Health, Spain.
| |
Collapse
|
8
|
Wolffsohn JS, Recchioni A, Hunt OA, Travé-Huarte S, Giannaccare G, Pellegrini M, Labetoulle M. Optimising subjective grading of corneal staining in Sjögren's syndrome dry eye disease. Ocul Surf 2024; 32:166-172. [PMID: 38490476 DOI: 10.1016/j.jtos.2024.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Revised: 02/13/2024] [Accepted: 03/12/2024] [Indexed: 03/17/2024]
Abstract
AIM To assess whether smaller increment and regionalised subjective grading improves the repeatability of corneal fluorescein staining assessment, and to determine the neurological approach adopted for subjective grading by practitioners. METHODS Experienced eye-care practitioners (n = 28, aged 45 ± 12 years), graded 20 full corneal staining images of patients with mild to severe Sjögren's syndrome with the Oxford grading scheme (both in 0.5 and 1.0 increments, globally and in 5 regions), expanded National Eye Institute (NEI) and SICCA Ocular Staining Score (OSS) grading scales in randomised order. This was repeated after 7-10 days. The digital images were also analysed objectively to determine staining dots, area, intensity and location (using ImageJ) for comparison. RESULTS The Oxford grading scheme was similar with whole and half unit grading (2.77vs2.81,p = 0.145), but the variability was reduced (0.14vs0.12,p < 0.001). Regional grade was lower (p < 0.001) and more variable (p < 0.001) than global image grading (1.86 ± 0.44 for whole increment grading and 1.90 ± 0.39 for half unit increments). The correlation with global grading was high for both whole (r = 0.928,p < 0.001) and half increment (r = 0.934,p < 0.001) grading. Average grading across participants was associated with particle number and vertical position, with 74.4-80.4% of the linear variance accounted for by the digital image analysis. CONCLUSIONS Using half unit increments with the Oxford grading scheme improve its sensitivity and repeatability in recording corneal staining. Regional grading doesn't give a comparable score and increased variability. The key neurally extracted features in assigning a subjective staining grade by clinicians were identified as the number of discrete staining locations (particles) and how close to the vertical centre was their spread, across all three scales.
Collapse
Affiliation(s)
- James S Wolffsohn
- School of Optometry, Health and Life Sciences, Aston University, Birmingham, UK.
| | - Alberto Recchioni
- School of Optometry, Health and Life Sciences, Aston University, Birmingham, UK; Academic Unit of Ophthalmology, Institute of Inflammation and Ageing, University of Birmingham, UK; Birmingham and Midland Eye Centre, Sandwell & West Birmingham NHS Trust, Birmingham, UK
| | - Olivia A Hunt
- School of Optometry, Health and Life Sciences, Aston University, Birmingham, UK
| | - Sònia Travé-Huarte
- School of Optometry, Health and Life Sciences, Aston University, Birmingham, UK
| | - Giuseppe Giannaccare
- Eye Clinic, Department of Surgical Sciences, University of Cagliari, Cagliari, Italy
| | - Marco Pellegrini
- Department of Translational Medicine, University of Ferrara, Ferrara, Italy
| | - Marc Labetoulle
- Ophthalmology Départment, Hôpitaux Universitaires Paris-Saclay, APHP, Université Paris-Saclay, IDMIT Infrastructure, Fontenay-aux-Roses Cedex, France
| |
Collapse
|
9
|
Valencia-Nieto L, López-de la Rosa A, López-Miguel A, González-García MJ. Clinical characterisation of contact lens discomfort progression. Cont Lens Anterior Eye 2024; 47:102096. [PMID: 38097423 DOI: 10.1016/j.clae.2023.102096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 10/15/2023] [Accepted: 11/27/2023] [Indexed: 01/22/2024]
Abstract
PURPOSE This study aimed to assess the subjective and objective differences among the steps of the contact lens discomfort (CLD) progression classification established by the Tear Film & Ocular Surface Society (TFOS) using questionnaires and clinical signs, and to propose a simplified classification. METHODS Contact lens (CL) wearers were evaluated in a single visit. The Contact Lens Dry Eye Questionnaire (CLDEQ)-8, the Contact Lens Discomfort Index, and Visual Analog Scales for discomfort and dryness were administered. The non-invasive break-up time, the tear film lipid layer thickness, conjunctival hyperaemia and papillae, lid-parallel conjunctival folds, the fluorescein tear film break-up time, corneal and conjunctival staining, lid wiper epitheliopathy, and the Schirmer test were assessed. Sign and symptom scores were compared among TFOS CLD progression steps using analysis of variance or the Kruskal-Wallis H test. Steps 1 and 2 (reduced comfort), and steps 3 and 4 (reduced wearing time) of the TFOS classification were combined to obtain a simplified classification, and the same comparison was performed. A p-value ≤ 0.05 was considered statistically significant. RESULTS One hundred-fifty CL wearers (97 women and 53 men) aged 34.4 ± 12.6 years were included. In the TFOS classification, there were significant differences between step 0 (no CLD) and the rest of the severity steps for the scores obtained in all questionnaires (p ≤ 0.015). All steps were differentiated (p ≤ 0.032) based on the simplified classification for all questionnaires, except steps 1 and 2 for the CLDEQ-8 and dryness VAS (p = 0.089 and p = 0.051, respectively). There were no differences (all p ≥ 0.06) between the sign scores among the steps of either classification. CONCLUSION CLD management is encouraged from its first appearance. Simplifying the phases of CLD severity may allow a more accurate classification and a better awareness of the problem by clinicians and CL wearers by using more straightforward simple messages.
Collapse
Affiliation(s)
- Laura Valencia-Nieto
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, University of Valladolid, Valladolid, Spain
| | - Alberto López-de la Rosa
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, University of Valladolid, Valladolid, Spain
| | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, University of Valladolid, Valladolid, Spain.
| | - María J González-García
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, University of Valladolid, Valladolid, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|
10
|
Cui D, Saldanha IJ, Li G, Mathews PM, Lin MX, Akpek EK. United States Regulatory Approval of Topical Treatments for Dry Eye. Am J Ophthalmol 2024; 258:14-21. [PMID: 37793479 DOI: 10.1016/j.ajo.2023.09.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 09/20/2023] [Accepted: 09/25/2023] [Indexed: 10/06/2023]
Abstract
PURPOSE To report the heterogeneity in methodology of clinical trials submitted to the US Food and Drug Administration (FDA) for approval of topical dry eye treatments. DESIGN Comparative analysis of clinical trials' methods. METHODS We reviewed the online, publicly available FDA database, application review files, ClinicalTrials.gov registry records, and journal articles for each FDA-approved topical dry eye treatment. For each trial, we extracted information about the study, patient demographics, treatment names and doses, sample size in each arm, and the measurement instrument in a systematic fashion. RESULTS Fourteen trials were included that assessed 5 topical treatments for dry eye (cyclosporine 0.05%, cyclosporine 0.09%, lifitegrast 5%, and loteprednol 0.25% eye drops and varenicline 0.03-mg nasal spray). Median treatment duration was 12 weeks (range, 2-24 weeks). In all trials, treatments, including varying concentrations of the same treatment, were compared with vehicle. Twelve trials (85.7%) evaluated a primary clinician-measured clinical sign, and 10 trials (71.4%) evaluated a primary patient-reported symptom. Corneal staining was the most frequently evaluated clinical sign primary outcome, reported in half (6 of 12) of the trials, and was graded using 4 different scoring systems. Conjunctival staining, conjunctival hyperemia, and tear production were each measured using 2 different scoring systems. Ocular discomfort, the only patient-reported symptom primary outcome, was measured using 5 different instruments. CONCLUSION A variety of outcome measures were used in these clinical trials. Clinically meaningful dry eye outcome measures and standardized measurements can optimize the assessment of and comparison of therapeutic benefits.
Collapse
Affiliation(s)
- David Cui
- From the Ocular Surface Disease Clinic, The Wilmer Eye Institute, Johns Hopkins University School of Medicine (D.C., G.L., P.M.M., M.X.L., E.K.A.), Baltimore, Maryland; The Krieger Eye Institute, Sinai Hospital of Baltimore (D.C.), Baltimore, Maryland
| | - Ian J Saldanha
- Center for Clinical Trials and Evidence Synthesis, Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health (I.J.S.), Baltimore, Maryland
| | - Gavin Li
- From the Ocular Surface Disease Clinic, The Wilmer Eye Institute, Johns Hopkins University School of Medicine (D.C., G.L., P.M.M., M.X.L., E.K.A.), Baltimore, Maryland
| | - Priya M Mathews
- From the Ocular Surface Disease Clinic, The Wilmer Eye Institute, Johns Hopkins University School of Medicine (D.C., G.L., P.M.M., M.X.L., E.K.A.), Baltimore, Maryland; Center For Sight (P.M.M.), Sarasota, Florida, USA
| | - Michael X Lin
- From the Ocular Surface Disease Clinic, The Wilmer Eye Institute, Johns Hopkins University School of Medicine (D.C., G.L., P.M.M., M.X.L., E.K.A.), Baltimore, Maryland
| | - Esen K Akpek
- From the Ocular Surface Disease Clinic, The Wilmer Eye Institute, Johns Hopkins University School of Medicine (D.C., G.L., P.M.M., M.X.L., E.K.A.), Baltimore, Maryland.
| |
Collapse
|
11
|
Calderón-García AÁ, Valencia-Nieto L, Valencia-Sandonis C, López-de la Rosa A, Blanco-Vazquez M, Fernández I, García-Vázquez C, Arroyo-Del Arroyo C, González-García MJ, Enríquez-de-Salamanca A. Gene expression changes in conjunctival cells associated with contact lens wear and discomfort. Ocul Surf 2024; 31:31-42. [PMID: 38128761 DOI: 10.1016/j.jtos.2023.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 10/27/2023] [Accepted: 12/09/2023] [Indexed: 12/23/2023]
Abstract
PURPOSE This study aimed to analyze the differences in the expression of pain-related genes in conjunctival epithelial cells among symptomatic contact lens (CL) wearers (SCLWs), asymptomatic CL wearers (ACLWs), and non-CL wearers (non-CLWs). METHODS For this study, 60 participants (20 non-CLWs, 40 CLWs) were enrolled. The CLW group comprised 20 ACLWs and 20 SCLWs according to the Contact Lens Dry Eye Questionnaire short form©. Conjunctival cells were collected using impression cytology, and RNA was isolated and used to determine the expression levels of 85 human genes involved in neuropathic and inflammatory pain. The effects of CL wear and discomfort were evaluated using mixed-effects ANOVA with partially nested fixed-effects model. Gene set enrichment analysis was performed to assign biological meaning to sets of differentially expressed genes. RESULTS Six genes (CD200, EDN1, GRIN1, PTGS1, P2RX7, and TNF) were significantly upregulated in CLWs compared to non-CLWs. Eleven genes (ADORA1, BDKRB1, CACNA1B, DBH, GRIN1, GRM1, HTR1A, PDYN, PTGS1, P2RX3, and TNF) were downregulated in SCLWs compared to ACLWs. These genes were mainly related to pain, synaptic transmission and signaling, ion transport, calcium transport and concentration, and cell-cell signaling. CONCLUSIONS CL wear modified the expression of pain- and inflammation-related genes in conjunctival epithelial cells. These changes may be in part, along with other mechanisms, responsible for CL discomfort in SCLWs.
Collapse
Affiliation(s)
- Andrés Ángel Calderón-García
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
| | - Laura Valencia-Nieto
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
| | - Cristina Valencia-Sandonis
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
| | - Alberto López-de la Rosa
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
| | - Marta Blanco-Vazquez
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - Itziar Fernández
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain; Department of Statistics and Operations Research, Universidad de Valladolid, Valladolid, Spain
| | - Carmen García-Vázquez
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - Cristina Arroyo-Del Arroyo
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain
| | - María J González-García
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Department of Theoretical Physics, Atomic and Optics, Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain.
| | - Amalia Enríquez-de-Salamanca
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|
12
|
Alotaibi S, Papas E, Ozkan J, Misra SL, Markoulli M. Behaviour of hTERT in the tears of neophyte contact lens wearers during the sleep/wake cycle. Cont Lens Anterior Eye 2023; 46:102060. [PMID: 37714745 DOI: 10.1016/j.clae.2023.102060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 08/16/2023] [Accepted: 09/04/2023] [Indexed: 09/17/2023]
Abstract
PURPOSE To investigate the behaviour of telomerase reverse transcriptase (hTERT) in the tears of healthy neophyte contact lenses-wearing individuals during the sleep/wake cycle. A subsequent aim was to investigate whether hTERT behaviour was associated with inflammatory mediators interleukin-6 (IL-6) and tumour necrosis factor-alpha (TNF-α) in tears. METHODS Flush tears were collected from 19 healthy, non-contact lens-wearing participants (11 males, 8 females, mean age 31.9 ± 5.7 years), before and during contact lens wear. Tears were collected at noon, before sleep and upon awakening and levels of hTERT, IL-6 and TNF-α, were determined using enzyme-linked immunosorbent assays (ELISA). RESULTS hTERT levels (median [interquartile range]) during contact lens wear were significantly higher before sleep (436.5 (263.9 - 697.7) ng/ml compared to the same time point without contact lenses (256.1 (0.0 - 590.9) ng/ml (p = 0.01). There was no difference between contact lens wear (851.3 [353.2 - 2109.9]) ng/ml, and no wear (1091.0 [492.3 - 3045.4]) ng/ml, upon awakening (p = 0.94). A significant increase was found upon awakening compared to before sleep, irrespective of the presence of a contact lens (p = 0.02). IL-6 and TNF-α levels in tears were below the limit of detection. CONCLUSIONS The study showed that hTERT increases after a contact lens is placed on the eye, but this change is small, compared to the impact of overnight eye closure. Taken together with the lack of responses of the inflammatory markers monitored at the same time points, this may suggest that hTERT can respond both to low-level stress stimuli acting on the ocular surface, and to situations where inflammation is a likely factor.
Collapse
Affiliation(s)
- Sultan Alotaibi
- School of Optometry & Vision Science, University of New South Wales, Sydney, Australia; Department of Optometry & Vision Science, College of Applied Medical Science, King Saud University, Riyadh, Saudi Arabia.
| | - Eric Papas
- School of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| | - Jerome Ozkan
- School of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| | - Stuti L Misra
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, The University of Auckland, New Zealand
| | - Maria Markoulli
- School of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
13
|
Fadel D. Medmont Meridia™: Much More Than a Corneal Topographer. CLINICAL OPTOMETRY 2023; 15:283-301. [PMID: 38054029 PMCID: PMC10695145 DOI: 10.2147/opto.s433899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Accepted: 11/08/2023] [Indexed: 12/07/2023]
Abstract
In recent years, advanced diagnostic instruments have become widely available in optometric practices, offering various functions that optimize clinical information gathering. This article focuses on the Medmont Meridia™, a state-of-the-art multipurpose diagnostic device with corneal topography and cutting-edge features. Corneal topography is pivotal in the early diagnosis of corneal disorders, determining baseline ocular surface assessment, helping in contact lens fitting, and monitoring ocular health over time. The Medmont Meridia boasts Placido-disc-based imaging with extensive corneal coverage. Furthermore, the Meridia accurately measures the horizontal visible iris diameter, pupil diameter, and palpebral fissure width, which assists in making contact lens parameter decisions. Additionally, it offers sagittal height data for scleral lens design and first lens selection, streamlining the fitting process. Beyond its topography capabilities, the Meridia excels as a comprehensive dry eye assessment tool. With features like tear meniscus height, tear film surface quality, and meibography capabilities, it aids in diagnosing dry eye and monitoring its progression. The device also provides customizable dry eye reports with integrated grading scales and questionnaires, making dry eye management, patient education, and compliance more accessible. In conclusion, the Medmont Meridia consolidates a multitude of examination tools in a single instrument, enhancing practice efficiency and elevating patient care and communication. Its versatility and accuracy make it an invaluable asset in optometric practices worldwide.
Collapse
Affiliation(s)
- Daddi Fadel
- Center for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
14
|
Tajbakhsh Z, Golebiowski B, Stapleton F, Alghamdi A, Gray PE, Altavilla B, Briggs N, Jalbert I. Increased dendritic cell density and altered morphology in allergic conjunctivitis. Eye (Lond) 2023; 37:2896-2904. [PMID: 36747109 PMCID: PMC10516863 DOI: 10.1038/s41433-023-02426-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 01/23/2023] [Accepted: 01/24/2023] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Corneal and conjunctival epithelial dendritic cells (DC) have an established role in vernal keratoconjunctivitis, however, their role in more prevalent forms of allergic eye disease remains unclear. This study evaluated corneal and conjunctival epithelial DC density, morphology, and distribution observed using in vivo confocal microscopy (IVCM) in allergic conjunctivitis. METHODS In this prospective, observational study, 66 participants (mean age 36.6 ± 12.0 years, 56% female): 33 with allergic conjunctivitis and 33 controls were recruited. IVCM was performed at the corneal centre, inferior whorl, corneal periphery, corneal limbus, and temporal bulbar conjunctiva. DC were counted and their morphology was assessed as follows: largest cell body size, presence of dendrites, and presence of long and thick dendrites. Mixed model analysis (DC density) and non-parametric tests (DC morphology) were used. RESULTS DC density was higher in allergic participants at all locations (p ≤ 0.01), (corneal centre median (IQR) 21.9 (8.7-50.9) cells/mm2 vs 13.1 (2.8-22.8) cells/mm2; periphery 37.5 (15.6-67.2) cells/mm2 vs 20 (9.4-32.5) cells/mm2; limbus 75 (60-120) cells/mm2 vs 58.1 (44.4-66.2) cells/mm2; conjunctiva 10 (0-54.4) cells/mm2 vs 0.6 (0-5.6) cells/mm2, but not at the inferior whorl 21.9 (6.2-34.4) cells/mm2 vs 12.5 (1.9-37.5) cells/mm2, p = 0.20. At the corneal centre, allergic participants had larger DC bodies (p = 0.02), a higher proportion of DC with dendrites (p = 0.02) and long dendrites (p = 0.003) compared to controls. CONCLUSIONS Corneal and conjunctival DC density was increased, and morphology altered in allergic conjunctivitis. These findings imply that the ocular surface immune response was upregulated and support an increased antigen-capture capacity of DC in allergic conjunctivitis.
Collapse
Affiliation(s)
- Zahra Tajbakhsh
- School of Optometry and Vision Science, UNSW, Sydney, NSW, Australia.
| | | | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW, Sydney, NSW, Australia
| | - Ali Alghamdi
- School of Optometry and Vision Science, UNSW, Sydney, NSW, Australia
| | - Paul E Gray
- Department of Immunology and Infectious Diseases, Sydney Children's Hospital, Sydney, NSW, Australia
| | - Betina Altavilla
- Department of Immunology and Infectious Diseases, Sydney Children's Hospital, Sydney, NSW, Australia
| | - Nancy Briggs
- Stats Central, Mark Wainwright Analytical Centre, UNSW, Sydney, NSW, Australia
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW, Sydney, NSW, Australia
| |
Collapse
|
15
|
Tajbakhsh Z, Golebiowski B, Stapleton F, Salouti R, Nowroozzadeh MH, Zamani M, Briggs N, Jalbert I. Dendritic Cell Density and Morphology Can Be Used to Differentiate Vernal Keratoconjunctivitis from Allergic Conjunctivitis. Biomolecules 2023; 13:1469. [PMID: 37892151 PMCID: PMC10605082 DOI: 10.3390/biom13101469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 09/22/2023] [Accepted: 09/26/2023] [Indexed: 10/29/2023] Open
Abstract
The aim of the study was to compare the distribution of corneal and conjunctival epithelial dendritic cells (DCs) in vernal keratoconjunctivitis (VKC), allergic conjunctivitis (AC), and non-allergic controls to examine if the allergy type causes differences in immune cell activation. The prospective study included 60 participants: 20 with VKC, 20 with AC, and 20 non-allergic controls. In vivo confocal microscopy was performed on the right eye. The locations scanned included the corneal centre, inferior whorl, corneal periphery, corneal limbus, and bulbar conjunctiva. The DCs were counted manually, and their morphology was assessed for the largest cell body size, the presence of dendrites, and the presence of long and thick dendrites. The DC density was higher in VKC and AC compared to non-allergic group at all locations (p ≤ 0.01) except at the inferior whorl. The DC density in VKC participants was significantly higher than in AC at the limbus (p < 0.001) but not at other locations. Both the AC and the VKC group had larger DC bodies at the corneal periphery and limbus compared to the non-allergic group (p ≤ 0.03). The study found a higher proportion of participants with DCs exhibiting long dendrites at both the corneal periphery in AC (p = 0.01) and at the corneal centre, periphery, and limbus in VKC, compared to the non-allergic group (p ≤ 0.001). In conclusion, a higher DC density at the limbus may be a marker of more severe VKC. DCs with larger cell bodies and a greater proportion of participants with DCs displaying long dendrites can be potential markers to differentiate allergy from non-allergy, and more severe forms of allergy from milder forms.
Collapse
Affiliation(s)
- Zahra Tajbakhsh
- School of Optometry and Vision Science, UNSW, Sydney, NSW 2052, Australia; (B.G.); (F.S.); (I.J.)
- Department of Optometry, School of Allied Health, University of Western Australia, Crawley, WA 6009, Australia
| | - Blanka Golebiowski
- School of Optometry and Vision Science, UNSW, Sydney, NSW 2052, Australia; (B.G.); (F.S.); (I.J.)
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW, Sydney, NSW 2052, Australia; (B.G.); (F.S.); (I.J.)
| | - Ramin Salouti
- Salouti Cornea Research Center, Salouti Eye Clinic, Shiraz 71839-33636, Iran; (R.S.); (M.Z.)
- Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz 71348-14336, Iran;
| | - M. Hosein Nowroozzadeh
- Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz 71348-14336, Iran;
| | - Mohammad Zamani
- Salouti Cornea Research Center, Salouti Eye Clinic, Shiraz 71839-33636, Iran; (R.S.); (M.Z.)
| | - Nancy Briggs
- Stats Central, Mark Wainwright Analytical Centre, UNSW, Sydney, NSW 2052, Australia;
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW, Sydney, NSW 2052, Australia; (B.G.); (F.S.); (I.J.)
| |
Collapse
|
16
|
Haworth K, Travis D, Leslie L, Fuller D, Pucker AD. Silicone hydrogel versus hydrogel soft contact lenses for differences in patient-reported eye comfort and safety. Cochrane Database Syst Rev 2023; 9:CD014791. [PMID: 37724689 PMCID: PMC10507745 DOI: 10.1002/14651858.cd014791.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
BACKGROUND Ocular discomfort is the leading cause of permanent discontinuation of soft contact lens (SCL) wear. Silicone hydrogel and hydrogel materials are the two major categories of SCLs, with silicone hydrogel materials being newer and more breathable than hydrogel materials. Whether comfort is associated with SCL material is controversial despite numerous studies. Similarly, the difference between these materials in terms of safety outcomes (e.g. frequency of microbial keratitis) is unclear. OBJECTIVES To evaluate the comparative effectiveness and safety of silicone hydrogel compared with hydrogel SCLs on self-reported comfort, dry eye test results, and adverse events in SCL-wearing adults 18 years of age or older. SEARCH METHODS The Cochrane Eyes and Vision Information Specialist searched the electronic databases for randomized controlled trials (RCTs). There were no restrictions on language or date of publication. We searched the Cochrane Central Register of Controlled Trials (CENTRAL, including the Cochrane Eyes and Vision Trials Register; 2022, Issue 6), MEDLINE Ovid, Embase.com, PubMed, LILACS (Latin American and Caribbean Health Science Information database), ClinicalTrials.gov, and World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP). We also searched the reference lists of identified studies, review articles, and guidelines for information about relevant studies that may not have been identified by our search strategy. Furthermore, we contacted investigators regarding ongoing trials. The most recent database search was conducted on 24 June 2022. SELECTION CRITERIA Our search selection criteria included RCTs, quasi-RCTs, and cross-over RCTs. DATA COLLECTION AND ANALYSIS We applied standard Cochrane methodology. MAIN RESULTS We included seven parallel-group RCTs conducted in the USA, the UK, Australia, Germany, India, and Turkey. A total of 1371 participants were randomized. The duration of SCL wear ranged from one to 52 weeks. Study characteristics and risk of bias The median number of participants per trial was 120 (interquartile range: 51 to 314), and the average age ranged from 20.7 to 33.0 years. Women represented the majority of participants (range 55% to 74.9%; 5 RCTs). Collectively, the included trials compared eight different silicone hydrogel SCLs with three different hydrogel SCLs. Five trials compared daily disposable SCLs, and two compared extended wear SCLs (worn for seven days and six nights). New SCL wearers were enrolled in three trials. Two trials included both new and established SCL wearers, and two trials did not report participants' history of SCL use. Five trials were sponsored by industry. We judged the overall risk of bias to be 'high' or 'some concerns' for the safety and efficacy outcomes. Findings One trial reported Ocular Surface Disease Index (OSDI) results, with the evidence being very uncertain about the effects of SCL material on OSDI scores (mean difference -1.20, 95% confidence interval [CI] -10.49 to 8.09; 1 RCT, 47 participants; very low certainty evidence). Three trials reported visual analog scale comfort score results, with no clear difference in comfort between materials, but the evidence was of very low certainty; trial results could not be combined because the three trials reported results at different time points. The evidence is very uncertain about the effect of SCL material on discontinuation of contact lens wear (risk ratio [RR] 0.64, 95% CI 0.11 to 3.74; 1 RCT, 248 participants). None of the included trials reported Contact Lens Dry Eye Questionnaire (CLDEQ-8) or Standard Patient Evaluation of Eye Dryness (SPEED) scores. There was no evidence of a clinically meaningful difference (> 0.5 unit) between daily disposable silicone hydrogel and hydrogel SCLs in corneal staining, conjunctival staining, or conjunctival redness (very low certainty evidence). Adverse events Very low certainty evidence from two trials comparing daily disposable SCLs suggested no evidence of a difference between lens materials in the risk of vision-threatening adverse events at one to four weeks (RR 0.68, 95% CI 0.08 to 5.51; 2 RCTs, 368 participants). Two trials comparing extended wear SCLs indicated that hydrogel SCLs may have a 2.03 times lower risk of adverse events at 52 weeks compared with silicone hydrogel SCLs (RR 2.03, 95% CI 1.38 to 2.99; 815 participants), but the certainty of evidence was very low. AUTHORS' CONCLUSIONS The overall evidence for a difference between all included silicone hydrogel and hydrogel SCLs was of very low certainty, with most trials at high overall risk of bias. The majority of studies did not assess comfort using a validated instrument. There was insufficient evidence to support recommending one SCL material over the other. For extended wear, hydrogel SCL may have a lower risk of adverse events at 52 weeks compared to silicon hydrogel. Future well-designed trials are needed to generate high certainty evidence to further clarify differences in SCL material comfort and safety.
Collapse
Affiliation(s)
| | - Darian Travis
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Louis Leslie
- Department of Ophthalmology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Daniel Fuller
- Cornea Contact Lens Service, The Eye Center, Southern College of Optometry, Memphis, TN, USA
| | - Andrew D Pucker
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| |
Collapse
|
17
|
Foo VHX, Liu YC, Tho B, Tong L. Quantum molecular resonance electrotherapy (Rexon-Eye) for recalcitrant dry eye in an Asian population. Front Med (Lausanne) 2023; 10:1209886. [PMID: 37771976 PMCID: PMC10523309 DOI: 10.3389/fmed.2023.1209886] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 08/28/2023] [Indexed: 09/30/2023] Open
Abstract
Objectives To assess the safety, efficacy, patients' satisfaction and acceptability of Rexon-Eye electrotherapy in treating Asian severe dry eye disease (DED) patients. Methods Prospective parallel-arm pilot study recruiting 40 DED Chinese patients with >moderate recalcitrant DED (Contact Lens Research Unit [CCLRU] > grade 2). Subjects were randomized into 2 groups, undergoing four weekly treatment sessions each: group 1 received full treatment power; group 2 received control treatment (power 1 treatment). Non-invasive tear break-up time (NIBUT), cornea fluorescein staining graded via CCLRU and Schirmer's I test were compared pre- and 2 months post-treatment. The SPEED and QUEST questionnaires that evaluated subjective symptoms and treatment satisfaction, respectively, at baseline and 2 weeks post-treatment were carried out. Tear cytokine levels in both groups were examined at 2 weeks post-treatment. Results The amount of improvement in post-treatment corneal staining in the inferior corneal zone was significant in Group 1 (p = 0.038) but not in Group 2 (p = 0.832). Group 1 eyes with worse baseline staining (total score >9.8) had a significantly greater reduction of corneal staining than those with better baseline staining (-11.7 ± 1.98 vs. -4.6 ± 2.89, p < 0.001). There were no other significant differences in NIBUT, Schirmer's 1 and cornea fluorescein staining grading within or between the groups.: Group 1 (n = 24) had improved subjective dryness scores compared to Group 2 (n = 16) (SPEED score: 6.38 + 4.16 vs. 10.0 + 6.36, p = 0.04). No significant differences were seen in 11 tear cytokine levels at 2 weeks post-treatment between the 2 groups. Conclusion In Asian DED patients treated with Rexon-Eye, inferior cornea staining showed significant improvement compared to placebo, and eyes with greater cornea staining at baseline achieved a greater improvement in staining. There were no other significant improvements in NIBUT and Schirmer's 1. Rexon-Eye also improved subjective DED scores in 41.7% of eyes without any adverse effects.
Collapse
Affiliation(s)
- Valencia Hui Xian Foo
- Ocular Surface Research Group, Singapore Eye Research Institute, Singapore, Singapore
- Corneal and External Eye Disease Service, Singapore National Eye Centre, Singapore, Singapore
| | - Yu-Chi Liu
- Corneal and External Eye Disease Service, Singapore National Eye Centre, Singapore, Singapore
- Eye-Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
| | - Bryan Tho
- Ocular Surface Research Group, Singapore Eye Research Institute, Singapore, Singapore
| | - Louis Tong
- Ocular Surface Research Group, Singapore Eye Research Institute, Singapore, Singapore
- Corneal and External Eye Disease Service, Singapore National Eye Centre, Singapore, Singapore
- Eye-Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| |
Collapse
|
18
|
Tajbakhsh Z, Jalbert I, Stapleton F, Alghamdi A, Gray PE, Briggs N, Altavilla B, Mobeen R, Golebiowski B. Dendritiform immune cells with reduced antigen-capture capacity persist in the cornea during the asymptomatic phase of allergic conjunctivitis. Eye (Lond) 2023; 37:2768-2775. [PMID: 36747108 PMCID: PMC10482935 DOI: 10.1038/s41433-023-02413-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 12/13/2022] [Accepted: 01/20/2023] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Increased density and altered morphology of dendritic cells (DC) in the cornea and conjunctiva occur during active allergic conjunctivitis. This study investigated whether inflammation (characterised by altered DC density and morphology) persists during the symptom-free phase of allergic conjunctivitis. METHODS Twenty participants (age 43.3 ± 14.3 years, 55% female) assessed during their active (symptomatic) phase of allergic conjunctivitis were re-examined during the asymptomatic phase. Ocular allergy symptoms and signs were evaluated during both phases, and five ocular surface locations (corneal centre, inferior whorl, corneal periphery, corneal limbus, and bulbar conjunctiva) were examined using in vivo confocal microscopy (HRT III). DC were counted manually, and their morphology was assessed for cell body size, presence of dendrites, presence of long dendrites and presence of thick dendrites using a grading system. Mixed model analysis (DC density) and non-parametric tests (DC morphology) were used to examine differences between phases. RESULTS DC density at corneal locations did not change between the active and asymptomatic phases (p ≥ 0.22). However, corneal DC body size was smaller and fewer DC presented with long dendrites during the asymptomatic phase (p ≤ 0.02). In contrast, at the bulbar conjunctiva, DC density was reduced during the asymptomatic phase compared to the active phase (p = 0.01), but there were no changes in DC morphology. CONCLUSIONS Dendritiform immune cell numbers persist in the cornea during the symptom-free phase of allergic conjunctivitis, whereas conjunctival DC appear to return to a baseline state. The morphology of these persisting corneal DC suggests their antigen-capture capacity is reduced during the asymptomatic phase.
Collapse
Affiliation(s)
- Zahra Tajbakhsh
- School of Optometry and Vision Science, UNSW, Sydney, Australia.
| | | | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW, Sydney, Australia
| | - Ali Alghamdi
- School of Optometry and Vision Science, UNSW, Sydney, Australia
| | - Paul E Gray
- Department of Immunology and Infectious Diseases, Sydney Children's Hospital, Sydney, Australia
| | - Nancy Briggs
- Stats Central, Mark Wainwright Analytical Centre, UNSW, Sydney, Australia
| | - Betina Altavilla
- Department of Immunology and Infectious Diseases, Sydney Children's Hospital, Sydney, Australia
| | - Rabia Mobeen
- School of Optometry and Vision Science, UNSW, Sydney, Australia
| | | |
Collapse
|
19
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
20
|
Prinz J, Maffulli N, Fuest M, Walter P, Hildebrand F, Migliorini F. Honey-Related Treatment Strategies in Dry Eye Disease. Pharmaceuticals (Basel) 2023; 16:ph16050762. [PMID: 37242545 DOI: 10.3390/ph16050762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 05/11/2023] [Accepted: 05/12/2023] [Indexed: 05/28/2023] Open
Abstract
This systematic review and meta-analysis investigated whether honey-related treatment strategies improve the signs and symptoms of patients with dry eye disease (DED). In March 2023, the following databases were accessed for clinical trials investigating the efficacy of honey-related treatment strategies in DED: PubMed, Web of Science, Google Scholar, and EMBASE. The following data were extracted at baseline and at the last follow-up: Ocular Surface Disease Index, tear breakup time, Schirmer I test, and corneal staining. Data from 323 patients were retrieved (53.3% female, mean age 40.6 ± 18.1 years). The mean follow-up was 7.0 ± 4.2 weeks. All the endpoints of interest significantly improved from baseline to the last follow-up: tear breakup time (p = 0.01), Ocular Surface Disease Index (p < 0.0001), Schirmer I test (p = 0.0001), and corneal staining (p < 0.0001). No difference was found in tear breakup time (p = 0.3), Ocular Surface Disease Index (p = 0.4), Schirmer I test (p = 0.3), and corneal staining (p = 0.3) between the honey-related treatment strategies and the control groups. According to our main results, honey-related treatment strategies are effective and feasible to improve symptoms and signs of DED.
Collapse
Affiliation(s)
- Julia Prinz
- RWTH University Hospital of Aachen, 52074 Aachen, Germany
| | - Nicola Maffulli
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081 Salerno, Italy
- Barts and The London School of Medicine and Dentistry, Mile End Hospital, Queen Mary University of London, 275 Bancroft Road, London E1 4DG, UK
- School of Pharmacy and Bioengineering, Keele University Faculty of Medicine, Thornburrow Drive, Stoke on Trent ST4 7QB, UK
| | - Matthias Fuest
- RWTH University Hospital of Aachen, 52074 Aachen, Germany
| | - Peter Walter
- RWTH University Hospital of Aachen, 52074 Aachen, Germany
| | | | - Filippo Migliorini
- RWTH University Hospital of Aachen, 52074 Aachen, Germany
- Department of Orthopaedics and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), 39100 Bolzano, Italy
| |
Collapse
|
21
|
Call T, Pucker AD, McGwin G, Franklin QX, Logan A. Real-Time Ocular Comfort Reporting in Monthly Replacement Contact Lens Wearers. CLINICAL OPTOMETRY 2023; 15:97-103. [PMID: 37181863 PMCID: PMC10167961 DOI: 10.2147/opto.s403319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 04/29/2023] [Indexed: 05/16/2023]
Abstract
Purpose To map contact lens (CL) comfort over the full wear day and across 1 month's wear in established, asymptomatic to minimally symptomatic, reusable, soft CL wearers. Methods Adult, 18- to 45-year-old, participants were recruited and required to have 20/20 best-corrected visual acuity or better and must have been asymptomatic to minimally symptomatic CL wearers. Participants were required to be able to wear TOTAL30® sphere CLs and have minimal astigmatism. Participants were fit in the study CLs and asked to wear these CLs daily for the next month for 16 hours per day each day. Participants were asked to complete a visual analog scale (VAS) survey via text message at time of CL application and after 8, 10, 12, 14, and 16 hours of wear and at CL removal on days 1, 2, 3, 4, and 5 and at 2 weeks and 1 month. The utilized VAS had a ±50 scale with positive scores being comfortable, negative scores being uncomfortable, and scores of 0 being neutral comfort. Results Forty-eight participants were recruited who had a mean ± SD age of 26.2 ± 5.2 years (71% female). Mean initial VAS CL comfort scores at initial CL dispense were 45.56 ± 9.20 units. Mean CL wear times for any of the days evaluated were at least 14.80 ± 2.41 hours per day and did not differ across the study (p = 0.77). Mean comfort VAS scores significantly decreased over the wear day (all days p ≤ 0.02), yet there were no significant differences in VAS comfort scores across the same time of day for the duration of the study (all times p ≥ 0.06). Conclusion This study determined that while CL wearers were slightly less comfortable at the end of the day compared to application, this comfort change was minimal given that the average participants had overwhelmingly good comfort at all time-points evaluated. Comfort scores were likewise consistent across 1 month of wear.
Collapse
Affiliation(s)
- Terri Call
- Department of Optometry and Vision Science, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Andrew D Pucker
- Department of Optometry and Vision Science, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Gerald McGwin
- Department of Epidemiology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Quentin X Franklin
- Department of Optometry and Vision Science, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Amy Logan
- Department of Optometry and Vision Science, University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
22
|
Tong L, Lim EWL, Yeo SWJ, Hou A, Linn YC, Ho A, Than H, Quek JKS, Hwang WYK, Lim FLWI, Lim L. Conjunctival T Cell Profile in Allogeneic Hematopoietic Stem Cell Transplant Patients after Instilling Topical Cyclosporine-A 0.1% Cationic Emulsion. Ophthalmol Ther 2023; 12:1547-1567. [PMID: 36856978 PMCID: PMC10164203 DOI: 10.1007/s40123-023-00686-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Accepted: 02/09/2023] [Indexed: 03/02/2023] Open
Abstract
INTRODUCTION To profile conjunctival T cell populations in allogeneic hematopoietic stem cell transplant (HSCT) patients after instillation of daily topical cyclosporine-A (CsA) 0.1% cationic emulsion (Ikervis), and to evaluate patients' tolerance to these eye drops. METHODS Nineteen participants were prescribed Ikervis prophylaxis once daily to both eyes from 3-5 weeks pre-HSCT to 12 months post-HSCT. The outcome measure was conjunctival T cell proportions from flow cytometry after impression cytology. Covariates included visual acuity, intraocular pressure, slit lamp and fundal examination, dry eye (SPEED) and quality of life questionnaires, non-invasive keratograph tear break-up time (NIKBUT), conjunctival redness, meibography, lipid thickness, Schirmer test, tear cytokines, fluorescein staining, tear osmolarity, and meibomian gland expressibility. RESULTS The conjunctival T cell analysis showed either stable or decreased proportions of conjunctival CD4 T cells at the last visit from baseline in compliant patients. CD4 proportions were increased in non-compliant patients and in the single patient who developed ocular graft-versus-host disease (GVHD). All patients were tolerant to Ikervis but 6/19 were not compliant. In the majority of patients, vision did not affect activities of daily living. Pre- and post-HSCT up to the last study visit, there was no statistically significant change in clinical covariates. Only one participant developed ocular GVHD at 9 months post-HSCT. CONCLUSION Superficial conjunctival T cell profile reflects compliance to daily topical Ikervis eye drops and clinical ocular surface parameters in allogenic HSCT patients. Tolerance is comparable to other formulations of topical CsA in the first 12 months. CLINICALTRIALS GOV IDENTIFIER NCT04636918. URL: https://clinicaltrials.gov/ct2/show/NCT04636918?cond=ocular+Graft+Versus+Host+Disease&cntry=SG&draw=2&rank=2 .
Collapse
Affiliation(s)
- Louis Tong
- Corneal and External Eye Disease Service, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore, 168751, Singapore.,Ocular Surface Research Group, Singapore Eye Research Institute, 20 College Road Discovery Tower Level 6, The Academia, Singapore, 169856, Singapore.,Eye-Academic Clinical Program, Duke-National University of Singapore Medical School, 8 College Road, Singapore, 169857, Singapore.,Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Elizabeth Wen Ling Lim
- Ocular Surface Research Group, Singapore Eye Research Institute, 20 College Road Discovery Tower Level 6, The Academia, Singapore, 169856, Singapore
| | - Sharon Wan Jie Yeo
- Ocular Surface Research Group, Singapore Eye Research Institute, 20 College Road Discovery Tower Level 6, The Academia, Singapore, 169856, Singapore
| | - Aihua Hou
- Ocular Surface Research Group, Singapore Eye Research Institute, 20 College Road Discovery Tower Level 6, The Academia, Singapore, 169856, Singapore.,Eye-Academic Clinical Program, Duke-National University of Singapore Medical School, 8 College Road, Singapore, 169857, Singapore
| | - Yeh Ching Linn
- Department of Haematology, Singapore General Hospital, 31 Third Hospital Ave, Singapore, 168753, Singapore
| | - Aloysius Ho
- Department of Haematology, Singapore General Hospital, 31 Third Hospital Ave, Singapore, 168753, Singapore
| | - Hein Than
- Department of Haematology, Singapore General Hospital, 31 Third Hospital Ave, Singapore, 168753, Singapore
| | - Jeffrey Kim Siang Quek
- Department of Haematology, Singapore General Hospital, 31 Third Hospital Ave, Singapore, 168753, Singapore
| | - William Ying Khee Hwang
- Department of Haematology, Singapore General Hospital, 31 Third Hospital Ave, Singapore, 168753, Singapore
| | | | - Li Lim
- Corneal and External Eye Disease Service, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore, 168751, Singapore. .,Ocular Surface Research Group, Singapore Eye Research Institute, 20 College Road Discovery Tower Level 6, The Academia, Singapore, 169856, Singapore. .,Eye-Academic Clinical Program, Duke-National University of Singapore Medical School, 8 College Road, Singapore, 169857, Singapore.
| |
Collapse
|
23
|
Morettin CE, Harthan JS, Huecker JB, Perera CD, Than T, Whiteside M, Johnson SD, Shorter E, Migneco MK, Olson CK, Alferez CS, Camp D, Hartwick ATE, Gordon MO. Correlation of Adenoviral Titers with Severity of Adenoviral Conjunctivitis and Time to Viral Clearance for 21 Days. Optom Vis Sci 2023; 100:187-193. [PMID: 36749104 PMCID: PMC10038925 DOI: 10.1097/opx.0000000000001999] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
SIGNIFICANCE This investigation reports the correlation of conjunctival viral titers in adenoviral conjunctivitis with patient-reported symptoms and clinician-graded signs for 21 days of follow-up. PURPOSE Adenoviral conjunctivitis is a highly contagious viral eye infection with significant morbidity and economic impact. This study investigates whether severity of signs and symptoms and time to viral clearance are correlated with conjunctival viral titers at baseline and during 21 days of follow-up. METHODS The Reducing Adenoviral Patient Infected Days study was a pilot study of the efficacy of a single in-office administration of ophthalmic 5% povidone-iodine. This article outlines longitudinal analyses after the primary outcome report. Of 212 participants screened, 28 participants with quantitative polymerase chain reaction-confirmed adenoviral conjunctivitis were randomized and had follow-up visits on days 1, 2, 4, 7, 14, and 21. At each visit, clinician-graded signs, participant-reported symptoms, and a conjunctival swab for quantitative polymerase chain reaction analysis were obtained. The correlation of viral titers with symptoms and signs was calculated: (1) cross-sectionally at each visit and (2) longitudinally for 21 days using a repeated-measures mixed-effects model. RESULTS Twenty-five of 28 participants had sufficient data for this report. Higher viral titers for 21 days were correlated with greater severity of symptoms (tearing, matting, and redness, r ≥ 0.70; P < .02) and greater severity of clinical signs (bulbar redness and serous discharge, r ≥ 0.60; P < .01). Eyes with highest baseline viral titers required longer time to viral clearance ( r = 0.59, P = .008). Signs and symptoms persisted in approximately half of the eyes even after viral clearance. CONCLUSIONS Higher conjunctival viral titers across 21 days were strongly correlated with more severe signs and symptoms and longer time to viral clearance. Our results also indicate that symptoms and signs can persist after viral clearance.
Collapse
Affiliation(s)
| | | | - Julia B Huecker
- Washington University School of Medicine, St. Louis, Missouri
| | | | - Tammy Than
- Carl Vinson VA Medical Center, Dublin, Georgia
| | | | - Spencer D Johnson
- Northeastern State University Oklahoma College of Optometry, Tahlequah, Oklahoma
| | | | - Mary K Migneco
- Washington University School of Medicine, St. Louis, Missouri
| | | | | | - Devon Camp
- Washington University School of Medicine, St. Louis, Missouri
| | | | - Mae O Gordon
- Washington University School of Medicine, St. Louis, Missouri
| |
Collapse
|
24
|
Twa MD. Optometry and Vision Science's Top Articles: The First 100 Years. Optom Vis Sci 2023; 100:183-186. [PMID: 36947572 DOI: 10.1097/opx.0000000000002000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/23/2023] Open
Affiliation(s)
- Michael D Twa
- Editor in Chief Optometry and Vision Science University of Houston College of Optometry Houston, TX
| |
Collapse
|
25
|
Abstract
AIM To enquire whether patients with dry eye symptoms also report dry skin, whether their perception could be corroborated with objective measurement, and whether dry eye disease might be suspected based on patients' complaints. METHODS This cross-sectional study included 50 subjects, 25 with and 25 without dry eye symptoms. Schein questionnaire was used to determine the severity of dry eye symptoms. Ocular signs were assessed by monitoring conjunctival hyperemia, ocular surface staining, meibomian gland expression, tear film lipid layer thickness, tear break-up time, lid parallel conjunctival folds, Schirmer test, and meibometry. Skin dryness was assessed by noting patients' self-perception of their facial skin dryness and measured by sebumeter. RESULTS Subjects without dry eye symptoms had self-reported oilier facial skin than those with dry eye symptoms (p < .001). Sebumetry scores measured on the forehead and cheek were significantly higher in subjects without dry eye symptoms than dry eye subjects (p = .003). After adjustment for age and gender in a logistic regression analysis, dry eye was independently and significantly associated with dry skin (AOR 0.69, p = .040), higher LIPCOF score of both eyes (AOR 2.28, p = .028), lower sebumetry score of the forehead (AOR 0.98, p = .041) and cheek (AOR 0.98, p = .041), and shorter TBUT score after gland expression (AOR 0.90, p = .018). CONCLUSION This study showed that ocular dryness was subjectively and objectively positively correlated to facial skin dryness. Patients reliably described their skin condition. People with dry facial skin also had drier eyes.
Collapse
Affiliation(s)
- Igor Petriček
- Department of Ophthalmology, Zagreb University Hospital Centre, Zagreb, Croatia.,School of Medicine, University of Zagreb, Zagreb, Croatia
| | - Sania Vidas Pauk
- Department of Ophthalmology, Zagreb University Hospital Centre, Zagreb, Croatia
| | - Martina Tomić
- Department of Ophthalmology, Vuk Vrhovac University Clinic, Merkur University Hospital, Zagreb, Croatia
| | - Tomislav Bulum
- School of Medicine, University of Zagreb, Zagreb, Croatia.,Department of Endocrinology, Vuk Vrhovac University Clinic for Diabetes, Endocrinology and Metabolic Diseases, Merkur University Hospital, Zagreb, Croatia
| |
Collapse
|
26
|
Garcia-Queiruga J, Pena-Verdeal H, Sabucedo-Villamarin B, Giraldez MJ, Garcia-Resua C, Yebra-Pimentel E. Meibomian gland secretion quality association with ocular parameters in university students during COVID- 19 restrictions. Int Ophthalmol 2023:10.1007/s10792-023-02632-2. [PMID: 36692700 PMCID: PMC9873396 DOI: 10.1007/s10792-023-02632-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 01/10/2023] [Indexed: 01/25/2023]
Abstract
PURPOSE To determine if the Meibomian Gland (MG) secretion quality is associated with symptoms of ocular discomfort, hours of Video Display Terminals (VDT) use, eyelid margin abnormalities, conjunctival hyperemia, and Meibomian Gland Loss Area (MGLA) in a sample of university students. METHODS An online survey that included an Ocular Surface Disease Index (OSDI) questionnaire and an extra question about hours of VDT use recruited an initial sample of 183 participants. Only 120 participants that fulfilled the inclusion criteria were scheduled for a battery of ocular surface and MG specific exam. The tests include: 1) meibometry, 2) slit lamp exploration of eyelid margin abnormalities (irregularity, hyperemia and MG orifices plugging), MG secretion quality and conjunctival hyperemia, and 3) Meibography. RESULTS Significant positive correlations between the MG secretion quality and eyelid margin hyperemia, MG orifices plugging, MGLA, nasal conjunctival hyperemia, and temporal conjunctival hyperemia (Spearman Rho; all r>0.186, p<0.042) were found. Multivariate regression found association between OSDI with hours of VDT use (B=0.316, p=0.007), and eyelid hyperemia (B=0.434, p≤ 0.001). A statistical association between MG secretion quality and eyelid margin hyperemia, MG orifices plugging, MGLA and conjunctival hyperemia (Fisher's exact; all p<0.039) were found. Multivariate regression found association between MG secretion quality with MG orifices plugging (B=0.295, p=0.004) and meibometry (B=-0.001, p=0.029). CONCLUSION Participants with higher values in MG secretion quality have higher values in eyelid margin hyperemia, MG plugging, MGLA, and conjunctival hyperemia. No direct relationship between MG secretion quality and hours of VDT use or OSDI were found.
Collapse
Affiliation(s)
- Jacobo Garcia-Queiruga
- GI-2092 - Optometry, Department of Applied Physics (Optometry Area), Universidade de Santiago de Compostela, Campus Vida s/n, Santiago de Compostela, Spain.
| | - Hugo Pena-Verdeal
- GI-2092 - Optometry, Department of Applied Physics (Optometry Area), Universidade de Santiago de Compostela, Campus Vida s/n, Santiago de Compostela, Spain
| | - Belén Sabucedo-Villamarin
- GI-2092 - Optometry, Department of Applied Physics (Optometry Area), Universidade de Santiago de Compostela, Campus Vida s/n, Santiago de Compostela, Spain
| | - Maria J Giraldez
- GI-2092 - Optometry, Department of Applied Physics (Optometry Area), Universidade de Santiago de Compostela, Campus Vida s/n, Santiago de Compostela, Spain
| | - Carlos Garcia-Resua
- GI-2092 - Optometry, Department of Applied Physics (Optometry Area), Universidade de Santiago de Compostela, Campus Vida s/n, Santiago de Compostela, Spain
| | - Eva Yebra-Pimentel
- GI-2092 - Optometry, Department of Applied Physics (Optometry Area), Universidade de Santiago de Compostela, Campus Vida s/n, Santiago de Compostela, Spain
| |
Collapse
|
27
|
Petriček I, Tomić M, Bulum T, Lešin Gaćina D, Vidas Pauk S. Meibomian Gland Assessment in Routine Ophthalmology Practice. Metabolites 2023; 13:metabo13020157. [PMID: 36837776 PMCID: PMC9964065 DOI: 10.3390/metabo13020157] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 12/30/2022] [Accepted: 01/16/2023] [Indexed: 01/22/2023] Open
Abstract
This cross-sectional study aimed to investigate the connection between meibomian gland (MG) excreta quantity and quality after MG expression (MGX), dry eye disease (DED) symptoms, and objective DED signs and to clarify the relationship between dry eye and MG function in DED pathophysiology. The study included 200 subjects, 100 with and 100 without dry eye symptoms. Schein questionnaire was used to determine the severity of dry eye symptoms and self-reported skin type for facial skin dryness self-evaluation. Objective dry eye signs were assessed by monitoring conjunctival hyperemia, lid parallel conjunctival folds (LIPCOF), tear break-up time (TBUT), fluorescein surface staining and digital MGX. Subjects with DED symptoms had significantly lower MG quantity scores than healthy controls (p < 0.001). Meibum quality and quantity scores significantly correlated with female gender (p = 0.002), Schein questionnaire score (p < 0.001), fluorescein corneal staining score (p = 0.019), self-reported skin type (p < 0.001), TBUT (p < 0.001) and LIPCOF (p = 0.041). After adjustment for age and gender in a logistic regression analysis, dry eye was independently and significantly associated with self-reported skin type (OR 0.73, p < 0.001), LIPCOF (OR 1.04, p < 0.001), fluorescein corneal staining (OR 1.05, p = 0.019), TBUT (OR 0.77, p < 0.001) and meibum quantity score (OR 0.59, p < 0.001). Dry eye symptoms and objective signs correlated well in this study. MGX discriminated between the subjects with and without DED symptoms and was associated with other objective DED signs. Results showed a significant association between meibum quality and quantity, MG function, DED and facial skin dryness self-perception. This paper established a correlation between dry eye symptoms caused by MG dysfunction and dry skin, which can help general health practitioners consider dry eye as a cause of chronic eye complaints with patients who report dry skin.
Collapse
Affiliation(s)
- Igor Petriček
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
- School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Martina Tomić
- Vuk Vrhovac University Clinic for Diabetes, Endocrinology and Metabolic Diseases, Merkur University Hospital, 10000 Zagreb, Croatia
| | - Tomislav Bulum
- School of Medicine, University of Zagreb, 10000 Zagreb, Croatia
- Vuk Vrhovac University Clinic for Diabetes, Endocrinology and Metabolic Diseases, Merkur University Hospital, 10000 Zagreb, Croatia
- Correspondence: ; Tel.: +385-1-2353-991; Fax: +385-1-2331-515
| | - Dina Lešin Gaćina
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
| | - Sania Vidas Pauk
- Department of Ophthalmology, Zagreb University Hospital Center, 10000 Zagreb, Croatia
| |
Collapse
|
28
|
Developing a Deep Learning Model to Evaluate Bulbar Conjunctival Injection with Color Anterior Segment Photographs. J Clin Med 2023; 12:jcm12020715. [PMID: 36675643 PMCID: PMC9867092 DOI: 10.3390/jcm12020715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/08/2023] [Accepted: 01/10/2023] [Indexed: 01/18/2023] Open
Abstract
The present research aims to evaluate the feasibility of a deep-learning model in identifying bulbar conjunctival injection grading. Methods: We collected 1401 color anterior segment photographs demonstrating the cornea and bulbar conjunctival. The ground truth was bulbar conjunctival injection scores labeled by human ophthalmologists. Two convolutional neural network-based models were constructed and trained. Accuracy, precision, recall, F1-score, Kappa, and the area under the curve (AUC) were calculated to evaluate the efficiency of the deep learning models. The micro-average and macro-average AUC values for model grading bulbar conjunctival injection were 0.98 and 0.98, respectively. The deep learning model achieved a high accuracy of 87.12%, a precision of 87.13%, a recall of 87.12%, an F1-score of 87.07%, and Cohen's Kappa of 0.8153. The deep learning model demonstrated excellent performance in evaluating the severity of bulbar conjunctival injection, and it has the potential to help evaluate ocular surface diseases and determine disease progression and recovery.
Collapse
|
29
|
Walker MK, Bailey LS, Basso KB, Redfern RR. Nonpolar Lipids Contribute to Midday Fogging During Scleral Lens Wear. Invest Ophthalmol Vis Sci 2023; 64:7. [PMID: 36630141 PMCID: PMC9840443 DOI: 10.1167/iovs.64.1.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
Purpose To determine correlations between lipids in the fluid reservoir (FR) and the severity of midday fogging (MDF) in scleral lens (SL) wear. Methods SL neophytes were recruited to wear custom SL for 4 days, examined after 8 hours on days 1 and 4. Lens vault and MDF were quantified from anterior segment optical coherence tomography (AS-OCT), and the FR was collected and analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Relative abundance of lipids was compared to MDF scores using nonparametric correlation testing (Spearman rank). Ocular surface and SL fitting characteristics (lens vault, fitting curves) were likewise compared to MDF. Results Thirteen participants (26 eyes, 69% female, 28 ± 9 years old) were included in this study. MDF severity after 8 hours of SL wear was 33 ± 29 units on day 1 and 28 ± 24 units on day 4 (r = .94; P < 0.01). Twelve samples were analyzed using LC-MS/MS, and a total of 170 distinct lipid species were detected. The lipid classes with greatest correlation to MDF were the wax esters (r = .73, P = 0.01), cholesteryl esters (r = .59; P = 0.049), and triacylglycerols (r = .64, P = 0.03). Polar lipids were observed abundantly in all samples. None of the measured ocular surface or fitting outcomes were correlated to MDF. Conclusions Nonpolar lipids were the greatest contributors to MDF among these normal participants. Polar lipids may be due to cellular debris, although they do not appear contributory to MDF.
Collapse
Affiliation(s)
- Maria K. Walker
- College of Optometry, The Ocular Surface Institute, University of Houston, Houston, Texas, United States
| | - Laura S. Bailey
- Department of Chemistry, University of Florida, Gainesville, Florida, United States
| | - Kari B. Basso
- Department of Chemistry, University of Florida, Gainesville, Florida, United States
| | - Rachel R. Redfern
- College of Optometry, The Ocular Surface Institute, University of Houston, Houston, Texas, United States
| |
Collapse
|
30
|
Qin G, Chao C, Lattery LJ, Lin H, Fu W, Richdale K, Cai C. Tear proteomic analysis of young glasses, orthokeratology, and soft contact lens wearers. J Proteomics 2023; 270:104738. [PMID: 36191803 DOI: 10.1016/j.jprot.2022.104738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 09/01/2022] [Accepted: 09/06/2022] [Indexed: 02/01/2023]
Abstract
Contact lens-related ocular surface complications occur more often in teenagers and young adults. The purpose of this study was to determine changes in tear proteome of young patients wearing glasses (GL), orthokeratology lenses (OK), and soft contact lenses (SCL). Twenty-two young subjects (10-26 years of age) who were established GL, OK, and SCL wearers were recruited. Proteomic data were collected using a data-independent acquisition-parallel accumulation serial fragmentation workflow. In total, 3406 protein groups were identified, the highest number of proteins identified in Schirmer strip tears to date. Eight protein groups showed higher abundance, and 11 protein groups showed lower abundance in the SCL group compared to the OK group. In addition, the abundance of 82 proteins significantly differed in children compared to young adult GL wearers, among which 67 proteins were higher, and 15 proteins were lower in children. These 82 proteins were involved in inflammation, immune, and glycoprotein metabolic biological processes. In summary, this work identified over 3000 proteins in Schirmer Strip tears. The results indicated that tear proteomes were altered by orthokeratology and soft contact wear and age, which warrants further larger-scale study on the ocular surface responses of teenagers and young adults separately to contact lens wear. SIGNIFICANCE: In this work, we examined the tear proteomes of young patients wearing glasses, orthokeratology lenses, and soft contact lenses using a data-independent acquisition-parallel accumulation serial fragmentation (diaPASEF) workflow and identified 3406 protein groups in Schirmer strip tears. Nineteen protein groups showed significant abundance changes between orthokeratology and soft contact lens wearers. Moreover, eighty-two protein groups significantly differed in abundance in children and young adult glasses wearers. As a pilot study, this work provides a deep coverage of tear proteome and suggests the need to investigate ocular responses to contact lens wear separately for children and young adults.
Collapse
Affiliation(s)
- Guoting Qin
- College of Optometry, University of Houston, Houston, TX 77204, United States of America; Mass Spectrometry Laboratory, Department of Chemistry, University of Houston, Houston, TX 77204, United States of America.
| | - Cecilia Chao
- College of Optometry, University of Houston, Houston, TX 77204, United States of America; School of Optometry and Vision Science, University of New South Wales, Sydney, NSW 2023, Australia
| | - Lauren J Lattery
- College of Optometry, University of Houston, Houston, TX 77204, United States of America
| | - Hong Lin
- Department of Computer Science & Engineering Technology, University of Houston - Downtown, Houston, TX 77002, United States of America
| | - Wenjiang Fu
- Department of Mathematics, University of Houston, Houston, TX 77204, United States of America
| | - Kathryn Richdale
- College of Optometry, University of Houston, Houston, TX 77204, United States of America
| | - Chengzhi Cai
- Mass Spectrometry Laboratory, Department of Chemistry, University of Houston, Houston, TX 77204, United States of America.
| |
Collapse
|
31
|
Chao C, Skidmore K, Tomiyama ES, Wolffsohn JS, Richdale K. Soft toric contact lens wear improves digital performance and vision-A randomised clinical trial. Ophthalmic Physiol Opt 2023; 43:25-34. [PMID: 36169043 DOI: 10.1111/opo.13053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 08/21/2022] [Accepted: 08/22/2022] [Indexed: 12/27/2022]
Abstract
PURPOSE To compare objective and subjective digital near visual performance and comfort in low to moderate astigmatic participants fitted with toric versus spherical equivalent silicone hydrogel daily disposable contact lenses. METHODS This was a double-masked, randomised, crossover study. Participants aged 18 to 39 years with astigmatism of -0.75 to -1.50 D were recruited and fitted with toric and spherical contact lenses, in random order. Outcomes were measured at baseline and after 1 week of wear with each contact lens type after the follow-up visits. High- and low-contrast near logMAR visual acuity, automated visual acuity, zoom (%), contrast (%), reading distance (cm), critical print size (logMAR) and reading speed were assessed. Participants also completed the validated Near Activity Visual Questionnaire (NAVQ) and Contact Lens Dry Eye Questionnaire 8 (CLDEQ-8) for each correction type. RESULTS Twenty-three participants completed the study (74% female, average age 24.4 ± 4.2 years). When participants wore toric contact lenses, near high- and low-contrast visual acuity and automated visual acuity improved by 3-4 letters (all p < 0.03) and participants were able to read faster on an iPad (p = 0.02). Participants were also able to read with 8% less contrast on the iPad with toric lenses (p = 0.01). Participants reported better subjective vision on the overall NAVQ (p = 0.001) and better comfort on the CLDEQ-8 (p = 0.02) with toric lenses. Fewer participants reported difficulty with maintaining focus at near, reading small print, reading labels/instructions, reading the computer display/keyboard and reading post/mail with toric correction. CONCLUSIONS Toric contact lenses improve comfort, subjective and objective visual performance with digital devices and other near tasks compared with the spherical equivalent correction in participants with low to moderate astigmatism.
Collapse
Affiliation(s)
- Cecilia Chao
- College of Optometry, University of Houston, Houston, Texas, USA
| | - Kelsea Skidmore
- College of Optometry, University of Houston, Houston, Texas, USA
| | - Erin S Tomiyama
- College of Optometry, University of Houston, Houston, Texas, USA
| | | | - Kathryn Richdale
- College of Optometry, University of Houston, Houston, Texas, USA
| |
Collapse
|
32
|
Tomiyama ES, Richdale K. Clinical Outcomes of a Randomized Trial with Contact Lenses for Astigmatic Myopia Management. Optom Vis Sci 2023; 100:9-16. [PMID: 36705710 PMCID: PMC9889106 DOI: 10.1097/opx.0000000000001969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
SIGNIFICANCE There are limited treatment options for myopia management of patients with moderate to high astigmatism. This work directly compares toric orthokeratology and soft toric multifocal lenses to show differences in visual acuity and patient satisfaction that could impact clinical care. Toric orthokeratology caused reduced visual acuity but was preferred subjectively for vision and overall. PURPOSE This study aimed to quantify objective and subjective clinical differences between toric orthokeratology and soft toric multifocal contact lenses in the same cohort of myopic wearers with moderate to high astigmatism. METHODS Thirty adults with refractive myopia (plano to -5.00 D) and astigmatism (1.25 to 3.50 D) were fitted empirically with both toric orthokeratology and soft toric multifocal contact lenses. Participants wore lenses for 10 days in random order, separated by a 14-day washout period. High-contrast visual acuity, low-contrast visual acuity, and glare logMAR visual acuity were measured. Surveys ascertained subject preference for comfort, vision, handling, and cost. Friedman, Wilcoxon signed rank, and χ2 tests were performed. RESULTS A subset of participants (n = 17) who achieved good vision with both lens types was analyzed. High-contrast and glare acuity with toric orthokeratology were reduced by one line compared with soft toric multifocal lenses (both 0.00 vs. -0.10, P ≤ .003). Participants preferred toric orthokeratology for vision ( P ≤ .03) but soft toric multifocal lenses for handling ( P ≤ .006). When forced to choose between lens types, participants preferred toric orthokeratology for vision and overall (both P ≤ .007). CONCLUSIONS Participants who achieved good vision with both lens types preferred toric orthokeratology over soft toric multifocal lenses, despite reduced high-contrast and glare visual acuity. Further research is needed to understand the relationship between visual performance and patient satisfaction.
Collapse
|
33
|
Pena-Verdeal H, Noya-Padin V, Losada-Oubiña M, Saborido-Rey M, Vilas-Alonso M, Giraldez MJ. Changes of symptomatology, tear film and ocular surface integrity one week during Somofilcon-A and Omafilcon-A lens wear. Eur J Ophthalmol 2022; 33:11206721221131131. [PMID: 36214157 DOI: 10.1177/11206721221131131] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2024]
Abstract
PURPOSE Clinicians play a key role in prescribing contact lenses that best suited for fitting which materials had an impact on ocular surface parameters. The present study aimed to evaluate the impact on symptomatology, tear film dynamics and ocular surface integrity of a silicone-hydrogel (Somofilcon-A) and a hydrogel (Omafilcon-A) lens before and after wearing for one week in contact lens neophyte participants. METHODS A Somofilcon-A and Omafilcon-A were randomly fitted to one or other the eye on an initial group of 28 participants. Subjects were scheduled for three sessions: basal session previous fitting, second session after 4-wear hours, and final session after 7-wear days for up to 10 h. In each session, CLDEQ-8, tear meniscus height and hyperemia with and without lenses, as well as lipid layer thickness and corneal/conjunctival staining without lenses were assessed. Values were compared between lenses and sessions. RESULTS In intrasession comparison, there were no differences in any parameter between materials on any session with or without lenses (all p≥0.176), except on the conjunctival staining where values obtained during Somofilcon-A wear (all p ≤ 0.006). In intersession analysis, CLDEQ-8 score, tear meniscus height and lipid layer thickness showed a statistical difference during both materials wear (all p ≤ 0.009), while conjunctival hyperemia does not (p = 0.237); corneal staining showed differences during Omafilcon-A wear (p = 0.037), contrary to conjunctival staining which showed differences only during Somofilcon-A wear (p < 0.001). CONCLUSION Contact lenses wear had an impact on ocular parameters that have some specific influences of the material on which lenses were manufactured.
Collapse
Affiliation(s)
- Hugo Pena-Verdeal
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Veronica Noya-Padin
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Martin Losada-Oubiña
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Marcos Saborido-Rey
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Manuel Vilas-Alonso
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Maria J Giraldez
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| |
Collapse
|
34
|
Effect of a single vectored thermal pulsation treatment of Meibomian gland dysfunction patients under controlled environmental conditions. Sci Rep 2022; 12:16761. [PMID: 36202938 PMCID: PMC9537290 DOI: 10.1038/s41598-022-20994-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 09/21/2022] [Indexed: 11/09/2022] Open
Abstract
To assess the prophylactic effect of LipiFlow treatment in Meibomian gland dysfunction (MGD) patients exposed to an adverse environmental humidity. MGD patients were exposed to normal (23 °C; 50% relative humidity; 30 min) and adverse (23 °C; 10% relative humidity; 2 h) controlled environments consecutively during baseline and follow-up visits (3, 6, and 12 months) after a single LipiFlow treatment. Ocular Surface Disease Index (OSDI), lipid layer thickness (LLT), fluorescein tear break-up time (TBUT), corneal and conjunctival staining, change in dry eye symptoms questionnaire (CDES-Q), and Meibomian gland yielding liquid secretion (MGYLS), were assessed. Linear mixed-effects and cumulative logit mixed models were fitted to assess the effect of the LipiFlow treatment over time and within the controlled environments. Seventeen females and 4 males (59.6 ± 9.4 years) completed the study. LLT and TBUT did not vary significantly (p > 0.05) after LipiFlow treatment. OSDI, corneal and conjunctival staining, and MGYLS scores were improved (p ≤ 0.01) 12 months after treatment. After the adverse exposure, corneal staining increased at all visits (p = 0.01), and there was no significant improvement in CDES-Q scores after LipiFlow treatment (p ≥ 0.07). One LipiFlow treatment improved objective and subjective outcomes in MGD disease for at least one year. Further studies are needed to support that LipiFlow might also help as an adjuvant to avoid acute flares against an adverse environmental humidity.
Collapse
|
35
|
Lievens CW, Norgett Y, Allen PM, Vianya-Estopa M. Development and validation of a new photographic scale to grade lid wiper epitheliopathy. Cont Lens Anterior Eye 2022; 46:101773. [DOI: 10.1016/j.clae.2022.101773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 10/03/2022] [Accepted: 10/18/2022] [Indexed: 11/03/2022]
|
36
|
Shorter ES, Whiteside MM, Harthan JS, Morettin CE, Perera CD, Johnson SD, Migneco MK, Huecker JB, Hartwick ATE, Than TP, Gordon MO. Diagnostic accuracy of clinical signs, symptoms and point-of-care testing for early adenoviral conjunctivitis. Clin Exp Optom 2022; 105:702-707. [PMID: 34751088 PMCID: PMC9081290 DOI: 10.1080/08164622.2021.1984180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 09/08/2021] [Accepted: 09/18/2021] [Indexed: 10/19/2022] Open
Abstract
CLINICAL RELEVANCE This study identifies key signs and symptoms of acute conjunctivitis, that when combined with a point-of-care test, can improve clinician accuracy of diagnosing adenoviral conjunctivitis. BACKGROUND Adenoviral conjunctivitis is a common ocular infection with the potential for high economic impact due to widespread outbreaks and subsequent furloughs from work and school. In this report, we describe clinical signs and participant-reported symptoms that most accurately identify polymerase chain reaction (PCR)-confirmed adenoviral conjunctivitis. METHODS Adults with 'red eye' symptoms of four days or less were enrolled. Participants rated 10 ocular symptoms from 0 (not bothersome) to 10 (very bothersome), and indicated the presence or absence of systemic flu-like symptoms. Clinicians determined the presence or absence of swollen lymph nodes and rated the severity of eight ocular signs using a 5-point scale. An immunoassay targeting adenovirus antigen was utilised for the point-of-care test, and conjunctival swab samples were obtained for subsequent adenovirus detection by PCR analyses. Univariate and multivariate logistic regression models were used to identify symptoms and signs associated with PCR-confirmed adenoviral conjunctivitis. The diagnostic accuracy of these clinical findings, and the potential benefit of incorporating point-of-care test results, was assessed by calculating areas under the receiver operating characteristic curves (AUC). RESULTS Clinician-rated bulbar conjunctival redness, participant-rated eyelid swelling and overall ocular discomfort had the best predictive value in the multivariate logistic regression model with an AUC of 0.83. The addition of the point-of-care test results to these three clinical sign/symptom scores improved diagnostic accuracy, increasing the AUC to 0.94. CONCLUSIONS Conjunctival redness severity and participant-reported eyelid swelling and overall discomfort, along with adenoviral point-of-care test results, were highly predictive in identifying individuals with PCR-confirmed adenoviral conjunctivitis. Improved diagnostic accuracy by clinicians at the initial presenting visit could prevent unnecessary work furloughs and facilitate earlier treatment decisions.
Collapse
Affiliation(s)
- Ellen S Shorter
- Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL, USA
| | | | | | | | - Chamila D Perera
- Division of Biostatistics, Washington University in St. Louis, MO, USA
| | - Spencer D Johnson
- Northeastern State University College of Optometry, Tahlequah, OK, USA
| | - Mary K Migneco
- Department of Ophthalmology and Visual Sciences, Washington University, St. Louis, MO, USA
| | - Julia B Huecker
- Department of Ophthalmology and Visual Sciences, Washington University, St. Louis, MO, USA
| | | | - Tammy P Than
- Department of Optometry, Carl Vinson Veterans Medical Center, Dublin, GA, USA
| | - Mae O Gordon
- Department of Ophthalmology and Visual Sciences, Washington University, St. Louis, MO, USA
| |
Collapse
|
37
|
Is contact lens discomfort related to meibomian gland morphology? Cont Lens Anterior Eye 2022; 45:101743. [PMID: 36028427 DOI: 10.1016/j.clae.2022.101743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 07/20/2022] [Accepted: 08/04/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE To examine the relationship between contact lens (CL) discomfort and meibomian gland (MG) morphology assessed by a semi-objective software in subjects without an alteration of MG function (meibum quality and expressibility). METHODS Nineteen symptomatic (CLDEQ-8 ≥ 12) CL wearers, 19 asymptomatic (CLDEQ-8 < 12) wearers, and 22 non-wearers were recruited. Upper and lower eyelid meibography images were taken and the following parameters were analysed using a semi-objective software in the central 2/3 of each eyelid: number of MG, number of partial MG, percentage of MG loss and percentage of tortuosity. One-way ANOVA or Kruskal-Wallis H test were used for comparisons among groups. The relationships between CLDEQ-8 and MG morphology parameters were analysed using the Spearman correlation coefficient and multivariable linear regression models. RESULTS No significant differences were found among groups in the MG morphology of the upper or lower eyelids. In all CL wearers, a significant correlation with CLDEQ-8 was found in the upper eyelid for the number of MG (rho = 0.47, p = 0.003). In symptomatic wearers, significant correlations with CLDEQ-8 were found in the lower eyelid for the number of partial MG (rho = 0.49, p = 0.03) and the percentage of partial MG (rho = 0.61, p = 0.005). In all CL wearers, multivariable models were fitted to explain CLDEQ-8 score including the number of MG, the number of partial MG and the percentage of MG loss from the lower eyelid (R2 = 0.19; p = 0.007), and the number of MG from the upper eyelid (R2 = 0.19; p = 0.001). In symptomatic wearers, a model was fitted including the percentage of MG loss from the lower eyelid (R2 = 0.30; p = 0.016). CONCLUSIONS Alterations of MG morphology, without clinically apparent alteration of MG function, can be involved in causing CL discomfort and influence the degree of symptoms. The differences in findings between eyelids indicate the need to monitor both eyelids, especially the lower one, in CL wearers.
Collapse
|
38
|
Vázquez A, Martínez-Plaza E, Fernández I, Sobas EM, González-García MJ, Enríquez-de-Salamanca A, Ortega E, López-Miguel A, Calonge M. Phenotypic characterization of patients developing chronic dry eye and pain after refractive surgery: A cross-sectional study. Ocul Surf 2022; 26:63-74. [DOI: 10.1016/j.jtos.2022.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 07/28/2022] [Accepted: 07/29/2022] [Indexed: 10/16/2022]
|
39
|
Markoulli M, Wong K, Jia T, Siddireddy JS, Briggs N, Tan J. The effect of hydroxypropyl-guar nanoemulsion on signs and symptoms of dry eye. Cont Lens Anterior Eye 2022; 45:101736. [PMID: 35835650 DOI: 10.1016/j.clae.2022.101736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 05/24/2022] [Accepted: 06/28/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE To examine the effect of hydroxypropyl-guar nanoemulsion (HP-Guar nanoemulsion, Alcon Laboratories Ltd, Fort Worth, TX, USA) versus saline (0.9% sodium chloride; Pfizer Inc., Bentley WA Australia) on the comfort and tear film properties of people with dry eye disease both in the short-term (up to 2 h post-drop instillation) and longer-term (after 4 weeks of 4-times daily use), and to examine the effect on tear inflammatory markers after 4 weeks. METHODS This was a prospective, investigator-masked, randomised, cross-over dispensing study. Twenty participants with dry eye disease (5 males: 15 females) with average age 46.9 ± 14.4 (range 26 to 70) years were randomized to either HP-Guar nanoemulsion, or saline eye drops. Ocular symptoms, lipid layer thickness, tear evaporation, tear osmolarity and non-invasive break-up time were measured pre-drop instillation, 1 h and 2 h post-eye drop instillation, and after 4-weeks of 4-times daily drop use. Tear inflammatory mediators were measured pre-drop instillation and after 4-weeks. After 4-weeks, patients had a 4-week washout period and then crossed over to the alternate drop. RESULTS With HP-Guar nanoemulsion, participants reported less grittiness/burning/stinging 1 h post eye drop instillation compared to baseline (79.5 ± 23.3 vs. 66.8 ± 27.7, p = 0.02); less dryness 1 h and 2 h post eye drop instillation compared to baseline (77.8 ± 23.0 and 76.2 ± 23.7 vs. 61.0 ± 27.1 respectively, p < 0.01 for both); and greater overall satisfaction 1 h post drop instillation and after 4 weeks of daily use compared to baseline (80.4 ± 21.6 and 83.4 ± 16.6 vs. 68.6 ± 26.0 respectively, p ≤ 0.011 for both). With saline, participants reported less dryness after 4 weeks of daily use compared to baseline (74.2 ± 23.8 vs. 60.2 ± 24.0, p < 0.01). For HP-Guar nanoemulsion, average lipid layer thickness was significantly thicker 2 h post drop-instillation (79.5 ± 21.7 nm) compared to baseline (63.7 ± 18.9 nm) and the 4-week assessment (62.4 ± 23.1 nm, p < 0.01 for both). For saline, average lipid layer thickness was significantly thicker at 1 h and 2 h post eye drop instillation (76.0 ± 23.8 nm and 80.4 ± 24.8 nm) compared to baseline (61.0 ± 15.6 nm, p < 0.01 for both). There was no difference in inflammatory mediators or other tear variables between drops or visits. CONCLUSION HP-Guar nanoemulsion was more effective for improving a range of subjective dry eye symptoms both in the short and long-term compared to saline. Both HP-Guar nanoemulsion and saline transiently increased lipid layer thickness.
Collapse
Affiliation(s)
- Maria Markoulli
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| | - Katherine Wong
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| | - Tianni Jia
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| | | | - Nancy Briggs
- Stats Central, UNSW Sydney, Sydney, NSW, Australia
| | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia.
| |
Collapse
|
40
|
Alotaibi S, Ozkan J, Papas E, Markoulli M. Diurnal Variation of Corneal Dendritic Cell Density. Curr Eye Res 2022; 47:1239-1245. [PMID: 35726825 DOI: 10.1080/02713683.2022.2088799] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Purpose: To measure variation in corneal dendritic cell density, and percentage of mature to total dendritic cells, in healthy individuals during the sleep/wake cycle.Methods: Using in vivo confocal microscopy, images of the subbasal nerve plexus were captured from 19 healthy, noncontact lens wearing participants. The central cornea and inferior whorl were imaged three times (midday, before sleep, upon awakening). Dendritic cell counts from the images were categorized according to perceived maturity (immature vs mature). Dendritic cell density and percentage of mature to total cells were compared between time points.Result: The median and interquartile range (IQR) of total dendritic cell density in the central cornea was 32.0 (7.0-131.3) cells/mm2 at midday, 37.1 (8.2-103.9) cells/mm2 before sleep, and 19.5 (7.0-83.2) cells/mm2 on awakening. Corresponding values for immature cells were 28.1 (5.8-112.5) cells/mm2, 22.3 (7.4-84.0) cells/mm2 and 18.0 (2.9-64.8) cells/mm2, and for mature cells, 3.1 (0.0-6.6) cells/mm2, 2.0 (0.8-16.8) cells/mm2, and 1.6 (0.2-8.2) cells/mm2. At the inferior whorl, total dendritic cell density was 38.5 (18.4-84.5) cells/mm2, 34.4 (9.4-82.3) cell/mm2, and 32.3 (15.2-96.1) cells/mm2. Immature cell density was 32.8 (18.4-80.9) cells/mm2, 34.4 (8.6-81.0) cells/mm2, and 32.3 (12.6-78.5) cells/mm2. Mature cell density was 1.6 (0.0-6.3) cells/mm2, 1.6 (0.0-3.1) cells/mm2, and 1.8 (0.0-6.3) cells/mm2. There was no significant difference between time points for total cell density (p > 0.05), but the percentage of mature cells upon awakening was significantly greater, compared to midday, at the central cornea (p = 0.02).Conclusion: In healthy individuals, overall corneal dendritic cell density is reasonably constant during the sleep/wake cycle, but the relative number of mature cells tends to increase overnight.
Collapse
Affiliation(s)
- Sultan Alotaibi
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.,Department of Optometry and Vision Science, College of Applied Medical Science, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Jerome Ozkan
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Eric Papas
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Maria Markoulli
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
41
|
Garcia-Queiruga J, Pena-Verdeal H, Sabucedo-Villamarin B, Garcia-Resua C, Giraldez MJ, Yebra-Pimentel E. Analysis of the Differences in Ocular Surface Damage and Inflammatory Signs between Healthy and Evaporative Dry Eye Participants. Ocul Immunol Inflamm 2022:1-8. [PMID: 35587256 DOI: 10.1080/09273948.2022.2075398] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE Distinguish between EDE severity levels by analysing the MGLA, conjunctival hyperemia and corneal staining. METHODS One hundred participants were recruited based on OSDI, TO, TFBUT, TMH, and LLP to be categorised as healthy (Group 1) or EDE (Group 2). Group 2 was divided into Group 2A (mild symptoms), 2B (moderate), and 2C (severe). MGLA, conjunctival hyperemia, and corneal staining were measured. RESULTS Positive correlation between MGLA, conjunctival hyperemia, and corneal staining were found (all r ≥ 0.221, p ≤ 0.027). Significant differences were found: MGLA between Group 1 vs. 2C and 2C vs. 2A or 2B; conjunctival hyperemia between Group 1 vs. 2A, 2B or 2C; corneal staining between Group 1 vs. 2B or 2C and 2A vs. 2B or 2C (all p ≤ 0.049). CONCLUSION Severe EDE participants have higher MGLA, conjunctival hyperemia, and corneal staining values than healthy, mild, or moderate EDE participants.
Collapse
Affiliation(s)
- Jacobo Garcia-Queiruga
- Departamento de Física Aplicada (Área de Optometría), Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| | - Hugo Pena-Verdeal
- Departamento de Física Aplicada (Área de Optometría), Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| | - Belén Sabucedo-Villamarin
- Departamento de Física Aplicada (Área de Optometría), Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| | - Carlos Garcia-Resua
- Departamento de Física Aplicada (Área de Optometría), Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| | - Maria J Giraldez
- Departamento de Física Aplicada (Área de Optometría), Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| | - Eva Yebra-Pimentel
- Departamento de Física Aplicada (Área de Optometría), Facultad de Óptica y Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| |
Collapse
|
42
|
Begley CG, Caffery B, Nelson JD, Situ P. The effect of time on grading corneal fluorescein and conjunctival lissamine green staining. Ocul Surf 2022; 25:65-70. [PMID: 35568371 DOI: 10.1016/j.jtos.2022.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 05/04/2022] [Accepted: 05/07/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE To explore the effect of time on grading corneal fluorescein and conjunctival lissamine green staining in dry eye disease (DED). METHODS Photographs of 68 subjects with non-Sjogren's DED (nSS DED) and 32 with Sjogren's DED (SS DED) were taken of corneal fluorescein staining, then conjunctival lissamine green staining every 30 s for at least 5 min. Photographs of one randomly selected eye were then randomly ordered and graded on a scale from 0 to 5 (severe staining) by two clinicians, masked to both site and subject. The average time required to reach the maximum grade of staining (Gmax) was calculated. RESULTS The median time (upper and lower quartiles) to corneal fluorescein Gmax was 2.6 (1.3-5.3) minutes for nSS DED and 3.8 (2.6-5.4) minutes for SS DED, a statistically significant difference (Mann Whitney U test, p = 0.018). In contrast, the median time to the Gmax for lissamine green staining of the nasal and temporal conjunctiva was 0.5 (0.5-1.1 nasal, 0.5-0.8 temporal) minutes for nSS DED and 0.5 (0.5-0.8 nasal, 0.5-0.5 temporal) minutes for SS DED subjects, which was not statistically significant (p ≥ 0.383). CONCLUSIONS The time required to reach the maximum grade of corneal fluorescein staining, but not conjunctival lissamine green staining, varied widely and was significantly longer in subjects with Sjögren's Syndrome. Early observation of corneal fluorescein staining can lead to under-grading, which may impact the diagnosis and assessment of treatment in DED. Further study of the best time to assess corneal fluorescein staining in various DED populations is warranted.
Collapse
Affiliation(s)
| | | | | | - Ping Situ
- Indiana University School of Optometry, Bloomington, IN, USA
| |
Collapse
|
43
|
Chandran Suja V, Verma A, Mossige E, Cui K, Xia V, Zhang Y, Sinha D, Joslin S, Fuller G. Dewetting characteristics of contact lenses coated with wetting agents. J Colloid Interface Sci 2022; 614:24-32. [DOI: 10.1016/j.jcis.2022.01.075] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 01/01/2022] [Accepted: 01/11/2022] [Indexed: 12/31/2022]
|
44
|
Lu W, Ning R, Diao K, Ding Y, Chen R, Zhou L, Lian Y, McAlinden C, Sanders FWB, Xia F, Huang J, Jin W. Comparison of Two Main Orthokeratology Lens Designs in Efficacy and Safety for Myopia Control. Front Med (Lausanne) 2022; 9:798314. [PMID: 35433737 PMCID: PMC9010613 DOI: 10.3389/fmed.2022.798314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 03/09/2022] [Indexed: 11/29/2022] Open
Abstract
Purpose This study aimed to compare the efficacy and safety of corneal refractive therapy (CRT) lenses and vision shaping treatment (VST) lenses for myopia control in children. Methods Medical records of 1,001 children (2,002 eyes) who had been fitted with orthokeratology lenses for over 1.5 years were retrospectively reviewed. We collected the clinical data of four types of orthokeratology (OK) lenses available: one CRT lens (brand: CRT) and three VST lenses (brands: Euclid, Alpha, and Hiline) over 1.5 years. Results were compared and analyzed using a one-way ANOVA and Pearson's chi-square test. Results Axial length elongation in the CRT lens group was 0.13 ± 0.02 mm faster than that in the Euclid lens, 0.1 ± 0.02 mm faster in the Alpha lens, and 0.08 ± 0.02 mm faster in the Hiline lens over the 1.5-year period (all P < 0.05). Among the subjects, 37.3% of them using the CRT lens experienced more than 1 D of refractive growth, compared with 20.2–30.8% of subjects wearing the three groups of VST lenses (all P < 0.05). A lower incidence of total adverse events was found with the CRT lenses compared with the VST lenses (P < 0.05), especially corneal staining. No difference was found in axial length elongation, refraction growth, and incidence of adverse events among the three types of VST lenses (all P > 0.05). Conclusions Compared with the VST lenses, CRT lenses demonstrated a weaker effect on myopia control but with a better safety profile. Different types of VST lenses had similar efficacy and safety in the context of controlling myopia progression.
Collapse
Affiliation(s)
- Weiwei Lu
- Eye Hospital and School of Optometry and Ophthalmology, Wenzhou Medical University, Wenzhou, China
- State Key Laboratory of Optometry, Ophthalmology, and Vision Science, Wenzhou, China
| | - Rui Ning
- Eye Hospital and School of Optometry and Ophthalmology, Wenzhou Medical University, Wenzhou, China
- State Key Laboratory of Optometry, Ophthalmology, and Vision Science, Wenzhou, China
| | - Kai Diao
- Eye Hospital and School of Optometry and Ophthalmology, Wenzhou Medical University, Wenzhou, China
- State Key Laboratory of Optometry, Ophthalmology, and Vision Science, Wenzhou, China
| | - Yang Ding
- Eye Hospital and School of Optometry and Ophthalmology, Wenzhou Medical University, Wenzhou, China
- State Key Laboratory of Optometry, Ophthalmology, and Vision Science, Wenzhou, China
| | - Ruru Chen
- Eye Hospital and School of Optometry and Ophthalmology, Wenzhou Medical University, Wenzhou, China
- State Key Laboratory of Optometry, Ophthalmology, and Vision Science, Wenzhou, China
| | - Lei Zhou
- Department of Ophthalmology, Ningbo Eye Hospital, Ningbo, China
| | - Yan Lian
- Eye Hospital and School of Optometry and Ophthalmology, Wenzhou Medical University, Wenzhou, China
- State Key Laboratory of Optometry, Ophthalmology, and Vision Science, Wenzhou, China
| | - Colm McAlinden
- Department of Ophthalmology, Singleton Hospital, Swansea Bay University Health Board, Singleton, United Kingdom
| | - Francis W. B. Sanders
- Department of Ophthalmology, Singleton Hospital, Swansea Bay University Health Board, Singleton, United Kingdom
| | - Fangfang Xia
- Eye Hospital and School of Optometry and Ophthalmology, Wenzhou Medical University, Wenzhou, China
- State Key Laboratory of Optometry, Ophthalmology, and Vision Science, Wenzhou, China
| | - Jinhai Huang
- Department of Ophthalmology, Eye Institute, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Jinhai Huang
| | - Wanqing Jin
- Eye Hospital and School of Optometry and Ophthalmology, Wenzhou Medical University, Wenzhou, China
- State Key Laboratory of Optometry, Ophthalmology, and Vision Science, Wenzhou, China
- *Correspondence: Wanqing Jin
| |
Collapse
|
45
|
Chao C, Lattery L, Qin G, Kamat M, Basso K, Lakkis C, Hasan M, Richdale K. Tear Proteomics of Children and Young Adult Soft Contact Lens, Orthokeratology and Spectacle Wearers - A Pilot Study. Curr Eye Res 2022; 47:832-842. [PMID: 35317695 DOI: 10.1080/02713683.2022.2047206] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
PURPOSE Contact lens complications occur more often in older teenagers and young adults compared to children. This study explored differences in tear proteomics between children and young adults wearing soft contact lens (SCL), orthokeratology or spectacles for >3 years. METHODS Twelve children and 12 sex- and correction-matched young adults were enrolled. Tears were collected via Schirmer strips for tear proteomic analysis using mass spectrometry. Proteome Discoverer was used for protein identification. Label-Free Quantitation was generated using Scaffold software; Fisher's Exact tests were used to compare proteins by age and correction groups. Generalized linear models were used to assess differences in overall protein levels by age and correction groups. A secondary analysis of proteins presented in >50% of samples of each group was conducted using the R/Bioconductor limma package. RESULTS There were 385 proteins present only in young adults while 183 were unique in children. There were 528 unique proteins to SCL, 96 to orthokeratology and 149 to spectacle wearers. Based on Fisher's Exact analyses, 126 proteins were higher in young adults than children (all P < 0.048). Forty-seven protein levels were higher in SCL compared to orthokeratology (all P < 0.01), 33 protein levels were higher in SCL compared to spectacles (all P < 0.01), 15 protein levels were higher in orthokeratology compared to spectacle wearers (all P < 0.01). Based on generalized linear models, young adults had higher overall protein levels than children (P = 0.001), SCL had higher protein levels than spectacle wearers (P < 0.001) but no differences were found between orthokeratology and spectacle wearers (P = 0.79). Based on the secondary analysis, only Antileukoproteinase was higher in the young adult orthokeratology group compared to other groups (P < 0.01). CONCLUSIONS Tear protein type and abundance differ by age and correction. Further research is needed to understand the effects of contact lens correction in children and young adults on the tear proteome.
Collapse
Affiliation(s)
- Cecilia Chao
- College of Optometry, University of Houston, Houston, TX, USA.,School of Optometry and Vision Science, University of New South Wales Sydney, Kensington, Australia
| | - Lauren Lattery
- College of Optometry, University of Houston, Houston, TX, USA
| | - Guoting Qin
- College of Optometry, University of Houston, Houston, TX, USA
| | - Manasi Kamat
- Department of Chemistry, University of Florida, Gainesville, FL, USA
| | - Kari Basso
- Department of Chemistry, University of Florida, Gainesville, FL, USA
| | - Carol Lakkis
- College of Optometry, University of Houston, Houston, TX, USA
| | | | | |
Collapse
|
46
|
The Effect of Past Cataract Surgery within the Medium to Long-Term Period on Patients with Dry Eye Disease. J Clin Med 2022; 11:jcm11040972. [PMID: 35207244 PMCID: PMC8878219 DOI: 10.3390/jcm11040972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/07/2022] [Accepted: 02/10/2022] [Indexed: 11/30/2022] Open
Abstract
This study investigates the effects of cataract surgery on dry eye parameters of patients with dry eye disease (DED) in the medium- to long-term post-surgical period (6 months to 5 years). A cross-sectional study was conducted on 438 eyes on first visit to a tertiary clinic (219 eyes with cataract surgery within timeframe, i.e., pseudophakic dry eye group, 219 comparison eyes without such history, i.e., comparison dry eye group). Parameters evaluated include Ocular Surface Disease Index (OSDI) and standard examination for DED. A significantly greater proportion of pseudophakic dry eye group (50%) experienced frequent blurred vision (≥1 episode per week) compared to dry eye control group (38%) (OR = 1.66, 95%CI 1.13, 2.44). Those with ocular discomfort before surgery were more likely to experience blurring at least once a day. However, a significantly greater proportion of the pseudophakic dry eye group (34%) had Schirmer’s I >8mm compared to the comparison group (25%) (OR = 0.605, 95% CI 0.398, 0.921), though the difference was not clinically significant (7.51 mm versus 6.51 mm, p > 0.05). Other DED signs (e.g., overall OSDI score, Tear Break-up Time) were not found to be worse among pseudophakic dry eye group. Pre-operative counselling and preventative measures should be undertaken, especially those with suggestive symptoms pre-operatively.
Collapse
|
47
|
Cheng C, Zhu M, Lin T, Chen Z, Zeng W, Li K, Xue R, Duan F, Wu K. Recharacterization of superior limbic keratoconjunctivitis via a subdividing grading method in 236 Chinese patients. Graefes Arch Clin Exp Ophthalmol 2022; 260:2291-2298. [PMID: 35113250 DOI: 10.1007/s00417-022-05575-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 01/17/2022] [Accepted: 01/21/2022] [Indexed: 11/04/2022] Open
Abstract
PURPOSE Superior limbic keratoconjunctivitis (SLK) is an uncommon and often overlooked chronic ocular surface disease. This retrospective consecutive case series study on Chinese patients aimed to characterize the features of this disease, including those undescribed in previous literature. METHODS Two hundred thirty-six patients diagnosed with SLK were enrolled into this consecutive case study from 2016 to 2019. The demographics, symptoms, Ocular Surface Disease Index, and ocular signs were collected and analyzed. A scoring system (SLK scale index, SSI) that integrated five major sign scores was applied to evaluate SLK severity. RESULTS Of the 236 SLK patients, dryness was the most common complaint (59.3%). Of 459 SLK eyes, superior limbus/conjunctival staining (SCS) was present in 98% eyes, followed by the superior tarsal conjunctival alterations (85.2%) and superior bulbar conjunctiva hyperemia (80.8%). Approximately 63% of eyes were accompanied by corneal staining. Superior bulbar conjunctivochalasis was a relatively rare sign (41.6%). Among the five major signs, only the prevalence of SCS gradually increased with its severity. In addition, fluorescein staining at the inferior limbus and adjacent conjunctiva (ICS) was found positive in 163 eyes of 84 patients (36%) who had significantly higher SSI than those without ICS (p = 0.013). CONCLUSIONS We found that SCS is the most common out of the 5 typical signs of SLK. ICS, a new sign, occurred in one-third of patients. SCS, a simple marker of SLK, as well as SSI, an integrated evaluation system, had the advantage of evaluating the severity and objectively characterizing SLK in clinical practice.
Collapse
Affiliation(s)
- Chao Cheng
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, People's Republic of China
| | - Minyi Zhu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, People's Republic of China.,Department of Ophthalmology, The Seventh Affiliated Hospital, Sun Yat-Sen University, Shenzhen, People's Republic of China
| | - Tianlan Lin
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, People's Republic of China
| | - Ziyan Chen
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, People's Republic of China
| | - Weiting Zeng
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, People's Republic of China
| | - Kunke Li
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, People's Republic of China
| | - Ran Xue
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, People's Republic of China
| | - Fang Duan
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, People's Republic of China
| | - Kaili Wu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-Sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, People's Republic of China.
| |
Collapse
|
48
|
Kalaiselvan P, Dutta D, Konda N, Vaddavalli PK, Sharma S, Stapleton F, Willcox MDP. Biocompatibility and Comfort during Extended Wear of Mel4 Peptide-Coated Antimicrobial Contact Lenses. Antibiotics (Basel) 2022; 11:antibiotics11010058. [PMID: 35052935 PMCID: PMC8772808 DOI: 10.3390/antibiotics11010058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 12/30/2021] [Accepted: 12/31/2021] [Indexed: 02/05/2023] Open
Abstract
(1) Purpose: This study aimed to investigate the effects of Mel4 antimicrobial contact lenses (MACL) on the ocular surface and comfort during extended wear. (2) Methods: A prospective, randomised, double-masked, contralateral clinical trial was conducted with 176 subjects to evaluate the biocompatibility of contralateral wear of MACL. The wearing modality was 14-day extended lens wear for three months. The participants were assessed at lens dispensing, after one night, two weeks, one month and three months of extended wear and one month after study completion. (3) Results: There were no significant differences (p > 0.05) in ocular redness or palpebral roughness between Mel4 and control eyes at any of the study visits. There was no significant difference (p > 0.05) in corneal staining between Mel4 and control eyes. There were no significant differences in front surface wettability or deposits or back surface debris (p > 0.05). No statistically significant differences (p > 0.05) were found in comfort, dryness, CLDEQ-8 scores lens or edge awareness. There was no evidence for delayed reactions on the ocular surface after cessation of lens wear. (4) Conclusion: The novel MACLs showed similar comfort to control lenses and were biocompatible during extended wear. Thus, these lenses were compatible with the ocular surface.
Collapse
Affiliation(s)
- Parthasarathi Kalaiselvan
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2041, Australia; (D.D.); (F.S.); (M.D.P.W.)
- Correspondence:
| | - Debarun Dutta
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2041, Australia; (D.D.); (F.S.); (M.D.P.W.)
- School of Optometry, Aston University, Birmingham B4 7ET, UK
| | - Nagaraju Konda
- School of Medical Sciences, University of Hyderabad, Hyderabad 500 046, India;
| | - Pravin Krishna Vaddavalli
- Bausch & Lomb Contact Lens Centre, L V Prasad Eye Institute, Hyderabad 500 034, India;
- The Cornea Institute, L V Prasad Eye Institute, Hyderabad 500 034, India
| | - Savitri Sharma
- Jhaveri Microbiology Centre, L V Prasad Eye Institute, Hyderabad 500 034, India;
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2041, Australia; (D.D.); (F.S.); (M.D.P.W.)
| | - Mark D. P. Willcox
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW 2041, Australia; (D.D.); (F.S.); (M.D.P.W.)
| |
Collapse
|
49
|
Than T, Morettin CE, Harthan JS, Hartwick AT, Huecker JB, Johnson SD, Migneco MK, Shorter E, Whiteside M, Olson CK, Alferez CS, van Zyl T, Rodic-Polic B, Storch GA, Gordon MO. Efficacy of a Single Administration of 5% Povidone-Iodine in the Treatment of Adenoviral Conjunctivitis. Am J Ophthalmol 2021; 231:28-38. [PMID: 34102153 DOI: 10.1016/j.ajo.2021.05.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 05/20/2021] [Accepted: 05/27/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE To evaluate the safety and efficacy of a single, in-office administration of 5% povidone-iodine (PVP-I) compared to artificial tears (AT) for adenoviral conjunctivitis (Ad-Cs). DESIGN Double-masked pilot randomized trial. METHODS Patients presenting with presumed adenoviral conjunctivitis were screened at 9 U.S. clinics. INCLUSION CRITERIA ≥18 years of age, symptoms ≤4 days, and a positive AdenoPlus test. EXCLUSION CRITERIA thyroid disease, iodine allergy, recent ocular surgery, and ocular findings inconsistent with early-stage Ad-Cs. Randomization was to a single administration of 5% PVP-I or AT in 1 eye and examinations on days 1-2, 4, 7, 14, and 21 with conjunctival swabs taken at each visit for quantitative polymerase chain reaction. Primary outcome was percent reduction from peak viral load. Secondary outcomes were improvement in clinical signs and symptoms. RESULTS Of 56 patients randomized, 28 had detectable viral titers at baseline. Day 4 posttreatment, viral titers in the 5% PVP-I and AT groups were 2.5% ± 2.7% and 14.4% ± 10.5% of peak, respectively (P = .020). Severity of participant-reported tearing, lid swelling, and redness as well as clinician-graded mucoid discharge, bulbar redness, and bulbar edema were lower in the 5% PVP-I group than AT group on day 4 (P < .05). After day 4, viral titers and severity of signs and symptoms decreased markedly in both groups and no differences between groups were detected. CONCLUSIONS Pilot data suggest a single, in-office administration of 5% PVP-I could reduce viral load and hasten improvement of clinical signs and symptoms in patients with Ad-Cs.
Collapse
|
50
|
A pilot study investigating the effect of extended contact lens wear on limbal and central corneal morphology. Cont Lens Anterior Eye 2021; 45:101524. [PMID: 34686432 DOI: 10.1016/j.clae.2021.101524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 09/29/2021] [Accepted: 10/05/2021] [Indexed: 11/23/2022]
Abstract
PURPOSE To investigate the effect of long-term extended soft contact lens wear on limbal and central corneal cell morphology, and limbal architecture. METHODS Each participant attended a study visit involving in vivo confocal microscopy of central corneal and limbal epithelium. Scans were graded by five masked graders for three features: central epithelial irregularity, limbal epithelial irregularity and the prominence of palisades of Vogt. The variability of grades between different graders and the difference of grades between extended wearers and daily soft/non-contact lens wearers were assessed. RESULTS Nineteen participants (9 extended soft contact lens wearers and 10 daily soft/non-contact lens wearers) aged 31-65 years were enrolled in this study. Scans from 37 eyes were included in the analysis. Agreement between graders for each feature was moderate to good with inter class correlation >0.7. While there were no significant differences in central epithelial cell irregularity (p = 0.527) and the prominence of palisade of Vogt (p = 0.182) between extended or daily soft/non-contact lens wearers, limbal epithelial cell irregularity showed a trend with increased irregularity in extended soft contact lens wearers (p = 0.091). CONCLUSIONS While no differences in limbal cell morphology and structureor central epithelial cell wasfound in thissubjective grading study of extended wearers compared to daily soft/non-contact lens wearers, further studies using a larger sample size or a longitudinal study design are warranted.
Collapse
|