1
|
Coelho JS, Soares IS, Lemos EA, Jimenez MCS, Kudó ME, Moraes SL, Ferreira AW, Sanchez MCA. A multianalyte Dot-ELISA for simultaneous detection of malaria, Chagas disease, and syphilis-specific IgG antibodies. Diagn Microbiol Infect Dis 2007; 58:223-30. [PMID: 17300910 DOI: 10.1016/j.diagmicrobio.2006.12.011] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2006] [Revised: 11/18/2006] [Accepted: 12/12/2006] [Indexed: 11/16/2022]
Abstract
A multianalyte Dot-enzyme-linked immunosorbent assay (Dot-ELISA-Multi) with Trypanosoma cruzi epimastigote alkaline extract (EAE), trypomastigote excreted-secreted antigen (TESA), recombinant protein derived from 19-kDa C-terminal region of the Plasmodium vivax merozoite surface protein 1 (PvMSP1(19)), Plasmodium falciparum Zwittergent extract (Pf-Zw), and Treponema pallidum Zwittergent extract (Tp-Zw) was standardized and evaluated as a method for surveying IgG-specific antibodies in Chagas disease, malaria, and syphilis in a single test. The study was carried out on serum samples from 52 patients with chronic Chagas disease, 103 individuals with current (parasitemic) or past malaria (aparasitemic), 43 patients with syphilis, 21 individuals with heterologous antibodies, and 100 blood donors. Dot-ELISA-Multi yielded 99% specificity for Chagas disease and 100% for malaria and syphilis. The test sensitivity was 100% for chronic Chagas disease, 88% for syphilis, 90% for P. vivax, and 47% for P. falciparum. In past malaria individuals, positivity was 92%. Therefore, Dot-ELISA-Multi can be useful under field conditions where laboratory facilities and resources are scarce, for small-scale epidemiologic studies.
Collapse
Affiliation(s)
- Juliana Santos Coelho
- Laboratório de Soroepidemiologia e Immunobiologia, Instituto de Medicina Tropical da Universidad de São Paulo, São Paulo, Brazil
| | | | | | | | | | | | | | | |
Collapse
|
2
|
Marangoni A, Sambri V, Storni E, D'Antuono A, Negosanti M, Cevenini R. Treponema pallidum surface immunofluorescence assay for serologic diagnosis of syphilis. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2000; 7:417-21. [PMID: 10799455 PMCID: PMC95888 DOI: 10.1128/cdli.7.3.417-421.2000] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A surface immunofluorescence assay (SIFA) using live spirochetes was analyzed and compared with Western blot (WB), fluorescent treponemal antibody absorption (FTA-ABS), microhemagglutination (MHA-TP), and Treponema pallidum immobilization (TPI) assays for detecting serum antibodies to T. pallidum in patients with syphilis, in disease controls, and in healthy subjects. SIFA and WB were 99% sensitive (99 of 100 positive specimens) and specific (140 of 140 negative specimens); FTA-ABS showed a sensitivity and a specificity of 90 and 89% (90 of 100 positive and 125 of 140 negative specimens), respectively. MHA-TP showed a sensitivity of 84% (84 of 100 positive specimens) and a specificity of 98.5% (138 of 140 negative specimens). Finally, TPI had a sensitivity of 52% (52 of 100 positive specimens) and a specificity of 100% (140 of 140 negative specimens). The T. pallidum SIFA was therefore highly specific, showing no equivocal reactivities with control sera, and sensitive. The results suggest the possible use of SIFA as a confirmatory test in the serologic diagnosis of syphilis.
Collapse
Affiliation(s)
- A Marangoni
- Sezione di Microbiologia, DMCSS, University of Bologna, St. Orsola Hospital, 40138 Bologna, Italy
| | | | | | | | | | | |
Collapse
|
3
|
Abstract
The organism that causes syphilis, Treponema pallidum, is impossible to culture in the clinical laboratory. Direct visualization of the pathogen is one laboratory technique used in the diagnosis of syphilis. Currently, serologic testing is the most widely used laboratory technique in diagnosing syphilis and monitoring its course after treatment. Serologic tests are divided into two categories, the nontreponemal and treponemal antibody tests. Newer techniques such as enzyme immunoassays have shown excellent results.
Collapse
Affiliation(s)
- B Clyne
- Division of Emergency Medicine, Department of Surgery, University of Maryland Medical System, Baltimore, MD 21201, USA
| | | |
Collapse
|
4
|
Ebel A, Bachelart L, Alonso JM. Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various stages of syphilis. J Clin Microbiol 1998; 36:358-61. [PMID: 9466741 PMCID: PMC104542 DOI: 10.1128/jcm.36.2.358-361.1998] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
The BioElisa Syphilis, a new competitive enzyme immunoassay (EIA) for Treponema pallidum whole antigen that uses specific human immunoglobulin G (IgG) antibodies as the competitor, was evaluated for potential use in screening for syphilis at various stages. The results obtained by this competitive EIA were compared with those obtained by the fluorescent treponemal antibody absorption (FTA-abs) test and the T. pallidum hemagglutination assay (TPHA). Serum samples from 434 patients with positive TPHA and FTA-abs test results, including patients with primary, latent, secondary, and tertiary syphilis and neurosyphilis, were investigated. Two samples tested negative by competitive EIA but were weakly reactive by the TPHA and the FTA-abs test. Sixteen serum samples from patients with clinically documented active syphilis, including several patients infected with human immunodeficiency virus, tested positive by the competitive EIA. There was a direct inverse correlation between EIA indices and titers in the TPHA and the FTA-abs test for all samples that tested positive. Specificity was assessed by testing 358 serum samples which tested negative for syphilis by TPHA and the FTA-abs test, including 100 serum samples from patients with documented infectious or autoimmune diseases. Only two serum samples gave a weakly positive EIA result. Thus, competitive EIA had a sensitivity of 99.5% and a specificity of 99.4% relative to the results of the FTA-abs test and TPHA. Our evaluation shows that BioElisa Syphilis is a sensitive, specific, and simple assay for screening for syphilis.
Collapse
Affiliation(s)
- A Ebel
- Institut Alfred Fournier, French National Reference Center for Sexually Transmitted Diseases, World Health Organization Collaborating Center for Treponematoses, Paris
| | | | | |
Collapse
|
5
|
Backhouse JL, Hudson BJ. Evaluation of immunoglobulin G enzyme immunoassay for serodiagnosis of yaws. J Clin Microbiol 1995; 33:1875-8. [PMID: 7665663 PMCID: PMC228289 DOI: 10.1128/jcm.33.7.1875-1878.1995] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
A commercially available enzyme immunoassay (EIA), the Captia Syphilis-G immunoglobulin G (IgG) EIA, for the detection of IgG antibodies to Treponema pallidum was evaluated for use as a screening test for yaws (Treponema pallidum subsp. pertenue). The IgG EIA was compared with the fluorescent treponemal antibody absorption (FTA-ABS) test. All sera were also examined by the T. pallidum hemagglutination test and the Venereal Disease Research Laboratory test. Serum samples from 271 subjects (23 control serum samples from an area nonendemic for yaws, 58 control serum samples from an area endemic for yaws, and 190 serum samples from yaws patients and contacts) were investigated. The overall agreement between the IgG EIA and the FTA-ABS test was 90%, the sensitivity was 99%, and the specificity was 70.2%. The specificity fell as the endemicity of the disease increased: from 94.4% in the nonendemic area controls to 86.4% in the endemic area controls and to 52.3% in the yaws contacts. There was no difference in specificity between children and adults within each of the three groups. Fifteen children with clinical yaws were monitored for 9 months after treatment. The level of treponemal antibody fell consistently in 9 of the 15 children as measured by the antibody index (ratio of absorbance of the test serum to the mean absorbance of the low-titer-positive controls). Reinfection was seen in three children, with the antibody index rising with the Venereal Disease Research Laboratory test titer. The Captia Syphilis-G test is a sensitive assay for the detection of treponemal antibodies in yaws patients. However, the apparent low specificity of the test in the yaws endemic area limits its use as a screening test for yaws.
Collapse
Affiliation(s)
- J L Backhouse
- Department of Clinical Microbiology, Westmead Hospital, New South Wales, Australia
| | | |
Collapse
|
6
|
Young H, Walker PJ, Merry D, Mifsud A. A preliminary evaluation of a prototype western blot confirmatory test kit for syphilis. Int J STD AIDS 1994; 5:409-14. [PMID: 7849118 DOI: 10.1177/095646249400500606] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
A prototype Western blot kit was evaluated as a confirmatory test for syphilis using 131 sera characterized by other serological tests for syphilis. There were 114 treponemal sera (including 94 cases of early syphilis, 83 of which were untreated) and 17 non-treponemal problem sera (11 gave false positive reactions on screening with the TmpA recombinant antigen enzyme immunoassay (EIA), 3 gave false positive fluorescent treponemal antibody absorbed (FTA-abs) tests, and 3 false positive Captia Syphilis G EIA results). Based on the manufacturer's criteria of reactivity in multiple bands for designating a positive result the Western blot test gave a sensitivity of 99.1% (113/114) and a specificity of 88.2% (15/17) when indeterminate reactions were scored positive and 98.2% (112/114) and 100% (17/17) when indeterminate reactions were scored negative. Sensitivity was high in both treated and untreated infection. Corresponding sensitivities for the TPHA and FTA-abs when equivocal reactions were scored negative were 97.5% (111/114) and 99.1% (113/114). The high sensitivity of the FTA-abs in this study is probably due to the large number of untreated primary infections. Our results with the Western blot, confirm earlier studies using 'in-house' test systems and, support a role for a commercial Western blot test in the confirmatory diagnosis of syphilis. Further studies are required to confirm the high specificity and sensitivity of the kit in a larger series including a wider variety of non-treponemal cases as well as patients with untreated and treated infection.
Collapse
Affiliation(s)
- H Young
- Department of Medical Microbiology, Edinburgh University Medical School, Scotland
| | | | | | | |
Collapse
|
7
|
Ozanne G, d'Halewyn MA, Larsen SA. Comparison of the fluorescent treponemal antibody absorption (FTA-ABS) test with the FTA-ABS double staining test for detection of antitreponemal immunoglobulin M in the 19S fraction of human serum. J Clin Microbiol 1993; 31:102-6. [PMID: 7678016 PMCID: PMC262629 DOI: 10.1128/jcm.31.1.102-106.1993] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
A widely used immunoglobulin M (IgM) detection assay for the diagnosis of neonatal congenital syphilis is the fluorescent treponemal antibody absorption test used with fractionated serum (FTA-ABS 19S IgM test). Reading the results of the FTA-ABS test is more cumbersome than reading those of the FTA-ABS double staining (FTA-ABS-DS) test, a confirmatory test for specific IgG. To verify that the FTA-ABS-DS test used with an anti-human IgM conjugate could detect specific IgM in fractionated serum samples (FTA-ABS-DS 19S IgM test), 164 fractionated (QUIK-SEP IgM Isolation System; ISOLAB, Inc., Akron, Ohio) serum specimens from infected neonates or adults or from IgG-seronegative subjects were tested by both techniques. The sensitivity limits of the two tests were assessed with reactive serum samples diluted to an endpoint titer. Samples nonreactive by the FTA-ABS 19S IgM test (n = 74) were either nonreactive (n = 65), minimally reactive (n = 5), or reactive (n = 4) by the FTA-ABS-DS 19S IgM test. Samples minimally reactive by the FTA-ABS 19S IgM test (n = 32) were minimally reactive (n = 1) or reactive (n = 31) by the double staining test. All samples reactive by the FTA-ABS 19S IgM test (n = 58) were also reactive by the FTA-ABS-DS 19S IgM test. There was a directly proportional linear relationship (r = 0.9794) between titers obtained by both tests. FTA-ABS-DS 19S IgM titers were constantly equal to or higher than FTA-ABS 19S IgM titers. Fluorescence intensity reading repeatability was 91.4% for the FTA-ABS-DS 19S IgM test and 81.7% for the FTA-ABS 19S IgM test (P = 0.015). Because the more easily read FTA-ABS-DS 19S IgM test is at least as sensitive as, if not more sensitive than, the FTA-ABS 19S IgM test, it is a good alternative to the latter test for the detection of specific IgM in human fractionated sera for those using fluorescence microscopes with incident light.
Collapse
Affiliation(s)
- G Ozanne
- Laboratoire de Santé Publique du Québec, Ste-Anne-de-Bellevue, Canada
| | | | | |
Collapse
|
8
|
|
9
|
Byrne RE, Laska S, Bell M, Larson D, Phillips J, Todd J. Evaluation of a Treponema pallidum western immunoblot assay as a confirmatory test for syphilis. J Clin Microbiol 1992; 30:115-22. [PMID: 1734042 PMCID: PMC265005 DOI: 10.1128/jcm.30.1.115-122.1992] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Tests for the detection of antibodies to Treponema pallidum are recommended for the confirmation of reactive nontreponemal test results and the accurate diagnosis of syphilis. The present-day use of Western blot (immunoblot) technology for the diagnosis of retroviruses prompted the development and evaluation of a Western blot assay with whole-cell T. pallidum as the antigen. The assay detected antibodies in syphilitic serum or plasma from dilutions of specimens incubated overnight with test strips. A test was considered positive when at least three of four major antigens having molecular masses of 15.5, 17, 44.5, and 47 kDa were detected. The Western blot assay had 93.8% sensitivity and 100% specificity for clinically defined samples. The Western blot assay was compared with double-staining fluorescent treponemal antibody absorption [FTA-ABS (DS)], which had a sensitivity and a specificity of 91.7 and 92.0%, respectively. Dilution series studies of syphilis-positive specimens indicated that the Western blot assay has an endpoint of reactivity at least 3 to 4 serial dilutions greater than that for FTA-ABS (DS). Overall, the greater than 95% agreement between the Western blot assay and FTA-ABS (DS) for clinically defined specimens indicates that the sensitivity of the Western blot assay is equal to or greater than that of FTA-ABS (DS). The Western blot assay demonstrated no false-positive or equivocal reactivities for nonsyphilitic specimens, including normal specimens (both plasma and serum), biological false-positives, and specimens with elevated gamma globulin or antinuclear antibody. We conclude that the high sensitivity and specificity of the T. pallidum Western blot assay, together with its simplicity and objectivity, make it a good confirmatory test for syphilis.
Collapse
Affiliation(s)
- R E Byrne
- Pandex Division, Baxter Diagnostics, Mundelein, Illinois 60060
| | | | | | | | | | | |
Collapse
|
10
|
Abstract
This article reviews the clinical manifestations of syphilis, diagnostic tests that might help to diagnose accurately the disease, and current recommendations for therapy. The association of syphilis and human immunodeficiency virus infection raises additional questions related to transmission, diagnosis, and therapy of both diseases.
Collapse
Affiliation(s)
- C M Hutchinson
- Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | | |
Collapse
|
11
|
Abstract
Luetic hearing loss, a relatively rare disorder, is significant because it is one of the few forms of progressive sensorineural hearing loss that may be reversed if diagnosed early and accurately and treated aggressively. With the increased incidence of systemic syphilis over the past few decades, the otolaryngologist can expect otosyphilis to appear more frequently. This report reviews the clinical presentation, histopathology, diagnostic workup, and current therapy for this disorder.
Collapse
Affiliation(s)
- G L Darmstadt
- Department of Surgery, University of California, San Diego 92103
| | | |
Collapse
|
12
|
|
13
|
Larsen SA, Hambie EA, Cruce DD. Review of the standard tests for syphilis and evaluation of a new commercial elisa, the syphilis bio-enzabead test. J Clin Lab Anal 1987. [DOI: 10.1002/jcla.1860010310] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|