1
|
Yin EZ, Yuan XF, Luo YX, Xiang PH, He L, Liao YL, Yi CL. Comparative Efficacy of Retrograde Pubic Ramus Intramedullary Nails and Percutaneous Cannulated Screws in Treating Anterior Pelvic Ring Fractures: A Retrospective Cohort Study. Curr Med Sci 2025; 45:341-348. [PMID: 40192888 DOI: 10.1007/s11596-025-00044-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2024] [Revised: 03/13/2025] [Accepted: 03/16/2025] [Indexed: 05/06/2025]
Abstract
OBJECTIVE To compare the clinical outcomes of retrograde pubic ramus intramedullary nail (RPRIN) and percutaneous cannulated screw (PCS) in the treatment of anterior pelvic ring fractures (APRFs). METHODS This retrospective cohort study included 45 patients with APRFs treated between February 2019 and October 2022 in our trauma center. Patients were divided into two groups based on the surgical method: 20 received RPRIN fixation, and 25 received PCS fixation. Key variables including operation time, fluoroscopic time, blood loss, and postoperative complications were analyzed. Fracture reduction quality was assessed using the Matta score system, and pelvic functional recovery was evaluated using the Majeed score system at the final follow-up. Quantitative variables were compared using the independent sample t test, while categorical variables were analyzed using Chi-square and Fisher's exact tests. RESULTS The RPRIN group had significantly shorter operation time (36.3 ± 5.6 min vs. 49.5 ± 6.9 min, P < 0.01), fluoroscopic time (32.0 ± 2.8 s vs. 48.4 ± 3.6 s, P < 0.01), and less blood loss (20.4 ± 7.6 mL vs. 34.0 ± 5.7 mL, P < 0.01) than the PCS group. Fracture reduction quality (Matta outcome) and pelvic functional recovery (Majeed outcome) were comparable between the two groups (P > 0.05). No significant complications were reported in either group. CONCLUSIONS Both RPRIN and PCS are effective for treating APRFs. However, RPRIN offers distinct advantages by reducing operation time, fluoroscopic time, and blood loss, making it a more efficient and less invasive option. Further multicenter studies and biomechanical analyses are warranted to confirm these findings.
Collapse
Affiliation(s)
- En-Zhi Yin
- Department of Traumatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Xue-Feng Yuan
- Department of Traumatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Yang-Xing Luo
- Department of Traumatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Peng-Hui Xiang
- Department of Traumatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Li He
- Department of Traumatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Yi-Liu Liao
- Department of Traumatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
| | - Cheng-la Yi
- Department of Traumatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
| |
Collapse
|
2
|
Huang S, He S, Kenmegne GR, Yin Y, Yu Y, Fang Y. Anterior subcutaneous internal fixator (INFIX) versus plate fixation for anterior ring injury in Tile C pelvic fractures: a retrospective study. BMC Surg 2025; 25:110. [PMID: 40119294 PMCID: PMC11927202 DOI: 10.1186/s12893-025-02844-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 03/13/2025] [Indexed: 03/24/2025] Open
Abstract
OBJECTIVES . The purpose of this study was to compare the reduction effect and clinical outcomes of anterior subcutaneous internal fixation (INFIX) and steel plate-screw internal fixation in the treatment of anterior ring injury in Tile C pelvic fractures. METHODS . In this retrospective study, the clinical outcomes of 46 patients treated using INFIX and 44 patients treated with steel plate-screw internal fixation were analyzed and compared. All patients underwent anterior and posterior fixation. The Matta imaging scoring system was used to evaluate the postoperative reduction accuracy; the Majeed scoring system was applied to obtain functional outcomes in clinical follow-up. All potential complications were identified and evaluated accordingly. RESULTS Both groups of patients were followed up for a period of 13-36 months, with an average of 27 months. The procedure time and blood loss in the INFIX group were significantly lower than those in the plate group(t = - 2.327, P = 0.023;t = - 4.053, P = 0.000; there was no statistically significant difference in the Majeed score and Matta score between the two groups after surgery (P > 0.05). CONCLUSIONS . INFIX treatment for anterior ring injury in Tile C pelvic fractures can achieve good therapeutic effects. Compared to internal fixation with plates and screws, it has advantages such as shorter surgical time and less blood loss. INFIX may be more suitable for obese patients, young women of childbearing age, or patients with urinary system injuries.
Collapse
Affiliation(s)
- Shenbo Huang
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Shuai He
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Guy Romeo Kenmegne
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Yijie Yin
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - You Yu
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Yue Fang
- Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China.
- Trauma center, West China Hospital of Sichuan University, Chengdu, 610041, China.
| |
Collapse
|
3
|
Li XS, Wu JL, Huang L, Ye L, Huang JF. Treatment of unstable pelvic fractures with double INFIX. BMC Musculoskelet Disord 2025; 26:37. [PMID: 39794709 PMCID: PMC11720955 DOI: 10.1186/s12891-024-08195-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 12/14/2024] [Indexed: 01/12/2025] Open
Abstract
BACKGROUND This study investigated the clinical efficacy of Double INFIX for the treatment of unstable pelvic fractures. METHODS We performed a retrospective analysis of 23 patients with unstable pelvic fractures treated using the Double INFIX minimally invasive technique. The cohort included five cases of Tile B1 type, eight cases of B2 type, six cases of B3 type, three cases of C1 type and one case of type C2. Pre- and postoperative evaluations included standardised pelvic serial films and three-dimensional CT scans. Key observational indicators were fracture reduction quality (assessed using Matta's criteria), fracture healing, functional recovery (evaluated with the Majeed function assessment criteria), and incidence of complications. RESULTS The mean follow-up duration was 24.48 ± 1.78 months. The average fracture healing time was 4.00 ± 1.41 months, and the average time for removal of fixation was 7.43 ± 1.75 months. Repeat imaging at 12 months postoperatively using Matta's criteria showed eight cases with excellent results (52.17%), 13 cases with good results (34.78%), three cases with fair results (13.04%), and no cases with poor results. The combined excellent and good rate was 86.96%, whereas the fair rate was 13.04%. The average Majeed hip joint function score at the final follow-up was 95.04 ± 1.72. Postoperative complications included meralgia paresthetica in two cases (8.7%) and sacrococcygeal discomfort in three patients when lying flat. CONCLUSION Double INFIX is a minimally invasive treatment technique with adequate clinical efficacy for managing unstable pelvic fractures.
Collapse
Affiliation(s)
- Xu-Song Li
- Zhongshan Hospital of Traditional Chinese Medicine Affiliated to Guangzhou University of Traditional Chinese Medicine, Zhongshan, Guangdong, 528400, China
| | - Jun-Le Wu
- Department of Orthopaedics & Traumatology, Zhongshan Hospital of Traditional Chinese Medicine Affiliated to Guangzhou University of Traditional Chinese Medicine, Zhongshan, Guangdong, 528400, China
| | - Liben Huang
- Guangzhou Hospital of Integrated Tradictional and West Medicine, Guangzhou, Guangdong, 510000, China
| | - Lin Ye
- Heyuan Woman and Children's Hospital and Health Institute, Heyuan, Guangdong, 517000, China
| | - Jie-Feng Huang
- Department of Orthopaedics & Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, Zhejiang, 310006, China.
| |
Collapse
|
4
|
Li J, He L, Xia C, Zhu M, Zhang W, Huang H. Comparison of the MIPPO technique and the modified Stoppa approach in the treatment of unstable anterior pelvic ring injuries: a retrospective cohort study. BMC Musculoskelet Disord 2024; 25:873. [PMID: 39482594 PMCID: PMC11526597 DOI: 10.1186/s12891-024-07989-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Accepted: 10/22/2024] [Indexed: 11/03/2024] Open
Abstract
BACKGROUND Anterior pelvic ring injuries have gradually become common. Using a minimally invasive technique to treat this injury may be feasible if the reduction and stability can be effectively achieved. We describe a percutaneous technique, minimally invasive percutaneous plate osteosynthesis (MIPPO), to fixate the anterior pelvis via establishing a subperiosteal tunnel between two limited incisions over the iliac crest(s) and pubic ramus in this research. METHODS A retrospective cohort study comparing the MIPPO technique (n = 60) versus the modified Stoppa approach (n = 53) for anterior pelvic ring injuries with posterior ring instability was performed from September 2016 to January 2023. The relative surgery variables, follow-up function evaluation, and complications were compared in two groups. The reduction quality of fracture was assessed according to the Matta criterion, and the functional score was evaluated using the Majeed score. RESULTS All patients completed follow-up, with an average interval of 39.90 ± 17.53 months (range 12-78). In the MIPPO technique group, the surgery interval and blood losses were lower compared to the modified Stoppa approach group (P<0.05). The mean procedure times and intraoperative blood losses were 69.56 ± 14.04 min/side (range 50-110) and 156.23 ± 49.75 mL/side (range 90-250) for unilateral anterior ring MIPPO fixation separately. All patients got a satisfactory reduction of the fracture. In the follow-up, earlier ambulation, shorter postoperative hospital stays, and lower complication rates were observed for patients using the MIPPO technique compared to the modified Stoppa approach (P<0.05). However, there is no statistical difference in these indicators including fracture union interval, full load time, the Majeed score, patient satisfaction level, and return to pre-injured work rate between the two groups. CONCLUSION This clinical experience gives support for the use of the MIPPO technique to stabilize the anterior pelvis. This minimally invasive technique was an effective and safe surgery method and could obtain satisfactory function results, particularly fitting to part of patients with resistance using the modified Stoppa approach.
Collapse
Affiliation(s)
- Jianwen Li
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Lingxiao He
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Chengyan Xia
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Meipeng Zhu
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Weikai Zhang
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China.
| | - Hui Huang
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China.
| |
Collapse
|
5
|
Hasegawa IG, Sakka B, Duong AM, Ding L, Wong MD, Gary JL, Patterson JT. Anterior internal versus external fixation of unstable pelvis fractures was not associated with discharge destination, critical care, length of stay, or hospital charges. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:2773-2778. [PMID: 38771369 PMCID: PMC11291563 DOI: 10.1007/s00590-024-03985-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 04/29/2024] [Indexed: 05/22/2024]
Abstract
PURPOSE Determine if anterior internal versus supra-acetabular external fixation of unstable pelvic fractures is associated with care needs or discharge. METHODS A retrospective cohort study was performed at two tertiary trauma referral centers. Adults with unstable pelvis fractures (AO/OTA 61B/61C) who received operative fixation of the anterior and posterior pelvic ring by two orthopedic trauma surgeons from October 2020 to November 2022 were included. The primary outcome was discharge destination. Secondary outcomes included intensive care unit (ICU) or ventilator days, length of stay, and hospital charges. RESULTS Eighty-three eligible patients were 38.6% female, with a mean age of 47.2 ± 20.3 years and BMI 28.1 ± 6.4 kg/m2. Fifty-nine patients (71.1%) received anterior pelvis internal fixation and 24 (28.9%) received external fixation. External fixation was associated with weight-bearing restrictions (91.7% versus 49.2%, p = 0.01). No differences in demographic, functional status, insurance type, fracture classification, or injury severity measures were observed by treatment. Internal versus external anterior pelvic fixation was not associated with discharge to home (49.2% versus 29.2%, p = 0.10), median ICU days (3.0 [interquartile range (IQR) 7.8 versus 5.5 [IQR 4.3], p = 0.14, ventilator days (0 [IQR 6.0] versus 0 [IQR 2.8], p = 0.51), length of stay (13.0 [IQR 13.0] versus 17.5 (IQR 20.5), p = 0.38), or total hospital charges (US dollars 180,311 [IQR 219,061.75] versus 243,622 [IQR 187,111], p = 0.14). CONCLUSIONS Anterior internal versus supra-acetabular external fixation of unstable pelvis fractures was not significantly associated with discharge destination, critical care, hospital length of stay, or hospital charges. This sample may be underpowered to detect differences between groups. LEVEL OF EVIDENCE Therapeutic Level IV.
Collapse
Affiliation(s)
- Ian G Hasegawa
- Dpeartment of Orthopaedic Surgery, Queens Medical Center, Honolulu, Hawaii, US
| | - Brandan Sakka
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo Street, Suite 2000, Los Angeles, CA, 90033-5322, US
| | - Andrew M Duong
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo Street, Suite 2000, Los Angeles, CA, 90033-5322, US
| | - Li Ding
- Department of Population and Public Health Sciences, Keck School of Medicine of University of Southern California, Los Angeles, CA, US
| | - Monica D Wong
- Department of Surgery, Keck School of Medicine of University of Southern California, Los Angeles, CA, US
| | - Joshua L Gary
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo Street, Suite 2000, Los Angeles, CA, 90033-5322, US
| | - Joseph T Patterson
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo Street, Suite 2000, Los Angeles, CA, 90033-5322, US.
| |
Collapse
|
6
|
Patterson JT, Parry JA, Working ZM, McKibben NA, Baca J, Duong A, Senior J, Kim A, Marchand LS, O'Hara N. Patient Preferences for Operative Versus Nonoperative Treatment of LC1 Pelvis Fracture: A Discrete Choice Experiment. J Orthop Trauma 2024; 38:291-298. [PMID: 38442188 DOI: 10.1097/bot.0000000000002794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/28/2024] [Indexed: 03/07/2024]
Abstract
OBJECTIVES To quantify how patients with lateral compression type 1 (LC1) pelvis fracture value attributes of operative versus nonoperative treatment. METHODS DESIGN Discrete choice experiment. SETTING Three US Level 1 trauma centers. PATIENT SELECTION CRITERIA Adult survivors of an LC1 pelvis treated between June 2016 and March 2023 were identified from institutional registries. The choice experiment was administered as a survey from March through August 2023. OUTCOME MEASURES AND COMPARISONS Participants chose between 12 hypothetical comparisons of treatment attributes including operative or nonoperative care, risk of death, severity of pain, risk of secondary surgery, shorter hospital stay, discharge destination, and independence in ambulation within 1 month of injury. The marginal utility of each treatment attribute, for example, the strength of participants' aggregate preference for an attribute as indicated by their survey choices, was estimated by multinomial logit modeling with and without stratification by treatment received. RESULTS Four hundred forty-nine eligible patients were identified. The survey was distributed to 182 patients and collected from 72 patients (39%) at a median 2.3 years after injury. Respondents were 66% female with a median age of 59 years (IQR, 34-69 years). Before injury, 94% ambulated independently and 75% were working; 41% received operative treatment. Independence with ambulation provided the highest relative marginal utility (21%, P < 0.001), followed by discharge to home versus skilled nursing (20%, P < 0.001), moderate versus severe postdischarge pain (17%, P < 0.001), shorter hospital stay (16%, P < 0.001), secondary surgery (15%, P < 0.001), and mortality (10%, P = 0.02). Overall, no relative utility for operative versus nonoperative treatment was observed (2%, P = 0.54). However, respondents strongly preferred the treatment they received: operative patients valued operative treatment (utility, 0.37 vs. -0.37, P < 0.001); nonoperative patients valued nonoperative treatment (utility, 0.19 vs. -0.19, P < 0.001). CONCLUSIONS LC1 pelvis fracture patients valued independence with ambulation, shorter hospital stay, and avoiding secondary surgery and mortality in the month after their injury. Patients preferred the treatment they received rather than operative versus nonoperative care.
Collapse
Affiliation(s)
- Joseph T Patterson
- Keck School of Medicine of the University of Southern California, Los Angeles, CA
| | - Joshua A Parry
- Denver Health Medical Center, University of Colorado School of Medicine, Denver, CO
| | | | | | - Joseph Baca
- Keck School of Medicine of the University of Southern California, Los Angeles, CA
| | - Andrew Duong
- Keck School of Medicine of the University of Southern California, Los Angeles, CA
| | - Joshua Senior
- Keck School of Medicine of the University of Southern California, Los Angeles, CA
| | - Annabel Kim
- Keck School of Medicine of the University of Southern California, Los Angeles, CA
| | | | - Nathan O'Hara
- University of Maryland Medical Center, Baltimore, MD
| |
Collapse
|
7
|
Meuser AH, Henyš P, Höch A, Gänsslen A, Hammer N. Evaluating the stability of external fixators following pelvic injury: A systematic review of biomechanical testing methods. J Mech Behav Biomed Mater 2024; 153:106488. [PMID: 38437754 DOI: 10.1016/j.jmbbm.2024.106488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 10/31/2023] [Accepted: 02/26/2024] [Indexed: 03/06/2024]
Abstract
INTRODUCTION This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation constructs. METHODS A systematic literature search was conducted to include biomechanical studies and to exclude clinical trials. RESULTS Of an initial 4666 studies found, 38 met the inclusion criteria. 84% of the included studies were retrieved from PubMed, Scopus, and Web of Science. The studies analysed 106 postmortem specimens, 154 synthetic bones, and 103 computational models. Most specimens were male (97% synthetic, 70% postmortem specimens). Both the type of injury and the classification system employed varied across studies. About 82% of the injuries assessed were of type C. Two different fixators were tested for FFPII and type A injury, five for type B injury, and fifteen for type C injury. Large variability was observed for external fixation constructs concerning device type and configuration, pin size, and geometry. Biomechanical studies deployed various methods to assess injury displacement, deformation, stiffness, and motion. Thereby, loading protocols differed and inconsistent definitions of failure were determined. Measurement techniques applied in biomechanical test setups included strain gauges, force transducers, and motion tracking techniques. DISCUSSION AND CONCLUSION An ideal fixation method should be safe, stable, non-obstructive, and have low complication rates. Although biomechanical testing should ensure that the load applied during testing is representative of a physiological load, a high degree of variability was found in the current literature in both the loading and measurement equipment. The lack of a standardised test design for fixation constructs in pelvic injuries across the studies challenges comparisons between them. When interpreting the results of biomechanical studies, it seems crucial to consider the limitations in cross-study comparability, with implications on their applicability to the clinical setting.
Collapse
Affiliation(s)
- Annika Hela Meuser
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria
| | - Petr Henyš
- Institute of New Technologies and Applied Informatics, Faculty of Mechatronics, Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec, Czech Republic
| | - Andreas Höch
- Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany
| | - Axel Gänsslen
- Clinic for Trauma Surgery, Orthopaedics and Hand Surgery, Wolfsburg Hospital, Wolfsburg, Germany
| | - Niels Hammer
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria; Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany; Division of Biomechatronics, Fraunhofer IWU, Dresden, Germany.
| |
Collapse
|
8
|
Xia W, Jiang H, Tao E, Ye J, Wang F, Wang X, Cai L, Feng Y. Comparison of ESIN and other minimally invasive techniques for anterior pelvic ring injury: a finite element analysis and case-control study. Int J Surg 2024; 110:2636-2648. [PMID: 38320104 DOI: 10.1097/js9.0000000000001137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 01/25/2024] [Indexed: 02/08/2024]
Abstract
OBJECT A novel technique, percutaneous elastic stable intramedullary nail fixation (ESIN), proposed by our team for the treatment of anterior pelvic ring injury. Finite element analysis and retrospective case-control study were used to compare biomechanical properties and clinical outcomes between ESIN and other techniques. METHODS Four groups of finite element models of pelvic anterior ring injury were simulated, including ESIN (model A), retrograde transpubic screw fixation (RTSF, model B), subcutaneous internal fixator (model C), and external fixator (model D), and a vertical downward load of 500 N was applied to the S1 vertebral endplate. Stress and displacement distributions of intact pelvis, displacement distributions of pubic fracture fragments, and stress distributions of fixation devices were analysed. Then 31 patients with anterior pelvic ring injury (15 in the ESIN group and 16 in the RTSF group) were reviewed. Clinical outcomes were evaluated at the final follow-up. Postoperative complications were also recorded. RESULTS Under 500N loading, the intact stability of the pelvis was compared as follows: model B (20.58 mm, 121.82 MPa), model A (20.80 mm, 129.97 MPa), model C (22.02 mm, 141.70 MPa), and model D (22.57 mm, 147.06 MPa). The regional stability of superior pubic ramus was compared as follows: model B (9.48 mm), model A (10.16 mm), model C (10.52 mm), and model D (10.76 mm). All 31 patients received follow-up at least 12 months postsurgery (range 12-20 months). Age, sex, injury mechanism, fracture type, time between the injury and operation, American Society of Anesthesiologists score, intraoperative blood loss, hospital stay, follow-up period, time to union, and Majeed scores did not differ significantly between the two groups ( P >0.05). However, the differences in the duration of unilateral surgery, unilateral intraoperative fluoroscopy and one-time success rate were significant ( P <0.05). CONCLUSIONS With sufficient biomechanical stability and minimally invasive advantage, the percutaneous technique using ESIN can be used to successfully treat anterior pelvic ring injuries. In addition, advantages over RTSF include a shorter duration of surgery, reduced requirement for intraoperative fluoroscopy, and a higher one-time success rate. ESIN therefore constitutes a good alternative to RTSF.
Collapse
Affiliation(s)
- Weijie Xia
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Hongyi Jiang
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Endong Tao
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Jianjun Ye
- West China Hospital of Sichuan University, Chengdu, People's Republic of China
| | - Fulin Wang
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Xianyu Wang
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Leyi Cai
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| | - Yongzeng Feng
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Zhejiang
| |
Collapse
|
9
|
Zhao P, Li R, Liu L, Wang X, Chen X, Guan J, Wu M. Clinical study of modified INFIX combined with sacroiliac joint screws for pelvic instable injuries. BMC Surg 2023; 23:350. [PMID: 37974146 PMCID: PMC10655463 DOI: 10.1186/s12893-023-02205-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 09/23/2023] [Indexed: 11/19/2023] Open
Abstract
OBJECTIVE The INFIX technique is becoming one of the most commonly performed surgical procedures for anterior pelvic ring instability injuries. The purpose of this article is to compare the clinical outcomes of modified anterior subcutaneous internal fixation (M-INFIX) with conventional anterior subcutaneous internal fixation (C-INFIX) for anterior pelvic ring instability injuries. PATIENTS AND METHODS A retrospective analysis of 36 cases of unstable pelvic injuries treated operatively at our institution, 20 of which were treated with C-INFIX and 16 with M-INFIX. Data collected included age, gender, ISS score, fracture typing, operative time, operative bleeding, postoperative complications, fracture healing time, Matta score, Majeed score, and follow-up time. Statistical sub-folding of each variable between the two groups was performed. RESULTS There was no statistical difference between the C-INFIX and M-INFIX groups in terms of age, gender, ISS (Injury Severity Score), follow-up time, fracture typing, fracture healing time, and Majeed score (P > 0.05). the M-INFIX had a significantly lower incidence of postoperative complications than the C-INFIX group, especially in the incidence of Lateral femoral cutaneous nerve (LFCN) injury (P < 0.05). In contrast, the M-INFIX group had statistically higher operative time, intraoperative bleeding, and Matta score than the C-INFIX group (P < 0.05). CONCLUSION This study was based on a modified application of the surgical experience with C-INFIX and showed better clinical outcomes in terms of complication rates and quality of repositioning than the conventional surgical approach. These findings indicate that further analytical studies of this study would be valuable.
Collapse
Affiliation(s)
- Peishuai Zhao
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Renjie Li
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Leyu Liu
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Xiaopan Wang
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Xiaotian Chen
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China
| | - Jianzhong Guan
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China.
| | - Min Wu
- Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China.
| |
Collapse
|
10
|
Zhang J, Zhang L, Li C, Chai W, Zhang L, Chen H, Zhang W, Hou Z, Chen B, Sun T, Tang P, Zhang Y. Clinical Guidelines for the Diagnosis and Treatment of Fragility Fractures of the Pelvis. Orthop Surg 2023; 15:2195-2212. [PMID: 37435891 PMCID: PMC10475682 DOI: 10.1111/os.13755] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 04/10/2023] [Accepted: 04/14/2023] [Indexed: 07/13/2023] Open
Abstract
BACKGROUND Fragility fractures of the pelvis (FFPs) are osteoporotic pelvic fractures or insufficiency pelvic fractures caused by the low energy injury or stress fracture in daily livings in the elderly more than 60 years, which the incidence is increasing with the aging population in our country. FFPs result in considerable morbidity and mortality and as well as massive financial burden on the already strained health systems throughout the world. METHODS This clinical guideline was initiated by the Trauma Orthopedic Branch of Chinese Orthopedic Association; the External Fixation and Limb Reconstruction Branch of Chinese Orthopedic Association; the National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation; Senior Department of Orthopedics of Chinese PLA general hospital; the Third Hospital of Hebei Medical University. The grading of recommendations assessment, development and evaluation (GRADE) approach and the reporting items for practice guidelines in healthcare (RIGHT) checklist were adopted. RESULTS 22 evidence based recommendations were formulated based on 22 most concerned clinical problems among orthopedic surgeons in China. CONCLUSION Understanding these trends through this guideline will facilitate better clinical care of FFP patients by medical providers and better allocation of resources by policy makers.
Collapse
Affiliation(s)
- Jianzheng Zhang
- Senior Department of OrthopedicsThe Fourth Medical Center of PLA General HospitalBeijingChina
- The National Clinical Research Center for OrthopedicsSports Medicine & RehabilitationBeijingChina
- The Trauma Orthopedic Branch of Chinese Orthopedic AssociationShijiazhuangChina
| | - Licheng Zhang
- Senior Department of OrthopedicsThe Fourth Medical Center of PLA General HospitalBeijingChina
- The National Clinical Research Center for OrthopedicsSports Medicine & RehabilitationBeijingChina
- The Trauma Orthopedic Branch of Chinese Orthopedic AssociationShijiazhuangChina
| | - Chunbao Li
- Senior Department of OrthopedicsThe Fourth Medical Center of PLA General HospitalBeijingChina
- The National Clinical Research Center for OrthopedicsSports Medicine & RehabilitationBeijingChina
| | - Wei Chai
- Senior Department of OrthopedicsThe Fourth Medical Center of PLA General HospitalBeijingChina
- The National Clinical Research Center for OrthopedicsSports Medicine & RehabilitationBeijingChina
| | - Lihai Zhang
- Senior Department of OrthopedicsThe Fourth Medical Center of PLA General HospitalBeijingChina
- The National Clinical Research Center for OrthopedicsSports Medicine & RehabilitationBeijingChina
- The Trauma Orthopedic Branch of Chinese Orthopedic AssociationShijiazhuangChina
| | - Hua Chen
- Senior Department of OrthopedicsThe Fourth Medical Center of PLA General HospitalBeijingChina
- The National Clinical Research Center for OrthopedicsSports Medicine & RehabilitationBeijingChina
- The Trauma Orthopedic Branch of Chinese Orthopedic AssociationShijiazhuangChina
| | - Wei Zhang
- Senior Department of OrthopedicsThe Fourth Medical Center of PLA General HospitalBeijingChina
- The National Clinical Research Center for OrthopedicsSports Medicine & RehabilitationBeijingChina
- The Trauma Orthopedic Branch of Chinese Orthopedic AssociationShijiazhuangChina
| | - Zhiyong Hou
- The Trauma Orthopedic Branch of Chinese Orthopedic AssociationShijiazhuangChina
- Group of Trauma Orthopaedics, Chinese Orthopaedic Association, Department of OrthopedicsThe Third Hospital of Hebei Medical UniversityShijiazhuangChina
| | - Bin Chen
- Department of Orthopedics, Southern HospitalSouthern Medical UniversityGuangzhouChina
| | - Tiansheng Sun
- Senior Department of OrthopedicsThe Fourth Medical Center of PLA General HospitalBeijingChina
- The National Clinical Research Center for OrthopedicsSports Medicine & RehabilitationBeijingChina
| | - Peifu Tang
- Senior Department of OrthopedicsThe Fourth Medical Center of PLA General HospitalBeijingChina
- The National Clinical Research Center for OrthopedicsSports Medicine & RehabilitationBeijingChina
- The Trauma Orthopedic Branch of Chinese Orthopedic AssociationShijiazhuangChina
| | - Yingze Zhang
- The Trauma Orthopedic Branch of Chinese Orthopedic AssociationShijiazhuangChina
- Group of Trauma Orthopaedics, Chinese Orthopaedic Association, Department of OrthopedicsThe Third Hospital of Hebei Medical UniversityShijiazhuangChina
| |
Collapse
|
11
|
Küper MA, Stöckle U, Stuby F, Trulson A. Clinical Experience with the New EASY (Endoscopic Approach to the Symphysis) Preparation Technique for Injuries of the Anterior Pelvic Ring. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2023; 161:211-217. [PMID: 35961324 DOI: 10.1055/a-1851-5389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
BACKGROUND High-energy injuries of the anterior pelvic ring and especially disruptions of the pubic symphysis usually require surgical stabilization. There is a conflict between biomechanical stability and size in the surgical approach. We have previously presented a minimally invasive approach for symphyseal plating. METHODS Our current endoscopic surgical technique is presented step-by-step and is illustrated in a video. The results and courses of the first seven patients treated with the EASY preparation are presented. RESULTS In all seven patients, the EASY preparation was successful. In four of the seven patients with an anterior pelvic ring injury, we performed a complete endoscopic plate osteosynthesis of the pubic symphysis. One patient gave consent only for endoscopic preparation, in one patient, we converted to open plate due to ventilation problems, and in one patient, the superior pubic rami fracture was stable. There were no surgical complications. CONCLUSION The EASY is a feasible minimally invasive preparation technique to stabilize anterior pelvic ring injuries in the most biomechanically stable manner by performing plate osteosynthesis. However, further scientific monitoring is necessary to improve the technique and validate our data.
Collapse
Affiliation(s)
- Markus Alexander Küper
- Klinik für Unfall- und Wiederherstellungschirurgie, BG Klinik Tübingen, Tübingen, Germany
| | - Ulrich Stöckle
- Centrums für Muskuloskeletale Chirurgie, Charite University Hospital Berlin, Berlin, Germany
| | - Fabian Stuby
- Unfallklinik, BG Unfallklinik Murnau, Murnau, Germany
| | - Alexander Trulson
- Klinik für Unfallchirurgie und Orthopädie, BG Unfallklinik Murnau, Murnau, Germany
| |
Collapse
|
12
|
Li XS, Huang LB, Kong Y, Fan MQ, Zheng Y, Huang JF. Modified percutaneous iliosacral screw and anterior internal fixator technique for treating unstable pelvic fractures: a retrospective study. BMC Musculoskelet Disord 2022; 23:1068. [PMID: 36471331 PMCID: PMC9724284 DOI: 10.1186/s12891-022-06036-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND The commonly used technique for treating unstable pelvic fractures with sacroiliac screws and anterior internal fixator (INFIX) is prone to complications, such as injury to the pelvic vasculature and nerves, life-threatening bleeding, lateral femoral cutaneous neuritis, and wound infection. This study investigated the clinical effects of using a modified percutaneous iliosacral screw and INFIX technique for treating unstable pelvic fractures. METHODS A retrospective analysis of minimally invasive internal fixation using modified incision of an anterior-ring INFIX application combined with modified percutaneous iliosacral screw placement was performed for 22 cases of unstable pelvic fractures from January 2017 to December 2018. Based on the Tile classification, there were 4 type B1, 7 type B2, 5 type B3 and 6 type C1 injuries. Preoperatively, the length and orientation of the internal fixation were computer-simulated and measured. On postoperative day 3, pelvic radiographs and three-dimensional computed tomograms were used to assess fracture reduction and fixation. All patients were regularly followed up at 4 weeks, 12 weeks, 6 months, 12 months, 24 months and annually thereafter. Fracture healing, complications, visual analogue scale (VAS) scores, the quality of fracture repositioning and Majeed score were assessed during follow-up. RESULTS All patients were followed up for a mean of 25.23 ± 1.48 months. All fractures healed without loss of reduction and no patient showed evidence of delayed union or nonunion. Two years postoperatively, the mean VAS score was 0.32 ± 0.09 and the mean Majeed score was 94.32 ± 1.86. CONCLUSION The modified percutaneous iliosacral screw technique increases the anterior tilt of the sacroiliac screw by shifting the entry point posteriorly to increase the safety of the screw placement. Downward modification of the INFIX incision reduces the risk of lateral femoral cutaneous nerve injury. This technique is safe, effective and well tolerated by patients.
Collapse
Affiliation(s)
- Xu-Song Li
- Department of Orthopaedics & Traumatology, Zhongshan Hospital of Traditional Chinese Medicine, Guangdong Zhongshan, 528401 China
| | - Li-Ben Huang
- Graduate school, Guangzhou University of Chinese Medicine, Guangdong Guangzhou, 510006 China
| | - Yu Kong
- Department of Pediatric, The Second Affiliated Hosptial of Zhejiang Chinese Medical University, Zhejiang Hangzhou, 310005 China
| | - Meng-Qiang Fan
- Department of Orthopaedics & Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Zhejiang Hangzhou, 310006 China
| | - Yang Zheng
- Department of Orthopaedics & Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Zhejiang Hangzhou, 310006 China
| | - Jie-Feng Huang
- Department of Orthopaedics & Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, Zhejiang Hangzhou, 310006 China
| |
Collapse
|
13
|
Tanaka K, Yoshida T, Hosoi K, Okubo N, Okada N, Takahashi K. Investigation of the risk of common femoral artery injury with anterior subcutaneous internal fixation in patients with fragility fractures of the pelvis. Injury 2022; 53:3781-3785. [PMID: 36045029 DOI: 10.1016/j.injury.2022.08.055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 08/19/2022] [Accepted: 08/23/2022] [Indexed: 02/02/2023]
Abstract
INTRODUCTION The incidence of the fragility fractures of the pelvis (FFPs) has been increasing in recent years. Operative treatment is effective in patients who are unable to ambulate due to pain. Anterior subcutaneous internal fixation (ASIF) is a minimally invasive and stable fixation used to treat the FFPs, with few reported vascular complications. However, we experienced a case in which the rod directly pressed the common femoral artery (CFA). OBJECTIVES The purpose of this study was to examine the relationship between the rod position as defined by ASIF and the CFA in the FFPs patients, and between BMI and the rod-to-CFA distance. MATERIALS AND METHODS Pelvic measurements were performed in 47 patients with FFPs using trauma CT. We identified the anterior inferior iliac spine (AIIS) on both sides in axial CT images. Next, we performed a simulation study using the CT images, in which the virtual fixation rod was bent according to the shape of the patients' abdomen in the supine position. The shortest rod-to-CFA distance when the virtual rod was positioned directly above the AIIS in the CT image was measured. The correlation between body mass index (BMI) and the rod-to-CFA distance was measured. RESULTS The average shortest rod-to-CFA distance was 18.4 ± 11.1 mm, and the simulated rod compressed the CFA in three of the 47 cases (6.4%). A statistically significant positive correlation between BMI and the rod-to-CFA distance was found (r = 0.47, p = 0.001). CONCLUSIONS The course of the CFA should be confirmed before ASIF surgery, and if there is danger of compression of the CFA such as in patients with low BMI, the rod-to-AIIS distance should be adjusted to the optimal distance. However, considering the disadvantages, such as decreased stability of the fixation, when adjusting the rod-to-AIIS distance, and skin irritation and abrasion by the rod, ASIF is not recommended in cases in which the rod is close to the CFA.
Collapse
Affiliation(s)
- Kazuya Tanaka
- Department of Orthopaedic Surgery, Kyotango Municipal Kumihama Hospital, Kyoto, Japan; Department of Orthopaedic Surgery, North Medical Center, Kyoto Prefectural University of Medicine, Kyoto, Japan.
| | - Takashi Yoshida
- Department of Orthopaedic Surgery, North Medical Center, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Kunihiko Hosoi
- Department of Orthopaedic Surgery, North Medical Center, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Naoki Okubo
- Department of Orthopaedic Surgery, North Medical Center, Kyoto Prefectural University of Medicine, Kyoto, Japan; Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Naoya Okada
- Department of Orthopaedic Surgery, North Medical Center, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Kenji Takahashi
- Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
| |
Collapse
|
14
|
Liu L, Fan S, Zeng D, Song H, Zeng L, Wen X, Jin D. Identification of safe channels for screws in the anterior pelvic ring fixation system. J Orthop Surg Res 2022; 17:312. [PMID: 35690864 PMCID: PMC9188702 DOI: 10.1186/s13018-022-03191-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 05/19/2022] [Indexed: 11/16/2022] Open
Abstract
Background Minimally invasive surgery for pelvic fracture using anterior ring internal fixator system is increasing gradually, and the way to insert the fixation screws in the fixation system is the key technical points of the method. However, there have been few studies on insertion of fixation screws for the anterior pelvic ring internal fixator system. Objective To identify safe channels for fixation screws in the anterior pelvic fixator system and provide the anatomical basis for insertion of fixation screws in clinical operation. Methods Screw insertion was simulated into a total of 40 pelvic finite element models as well as 16 fresh pelvic specimens, and the channel parameters were measured. Results Finite elements (male, female) include: screws in ilium: length 114.4 ± 4.1 and 107.6 ± 8.3 mm, respectively; diameter 11.7 ± 0.5 and 10.0 ± 0.6 mm, distance between screw and anterior inferior iliac spine: 5.5 ± 1.0 and 5.6 ± 1.0 mm, angle of coronal plane 55.8° ± 2.4° and 50.6° ± 3.1°, angle of sagittal plane 26.6° ± 1.0° and 24.5° ± 1.9° and angle of horizontal plane 64.9 ± 3.7 and 58.1 ± 3.1; screws in pubis: length 47.0 ± 2.0 and 39.8 ± 3.9 mm, diameter 7.1 ± 0.4 and 6.1 ± 0.4 mm. Specimens (male, female) include: distance between screw and anterior inferior iliac spine: 5.5 ± 0.5 and 5.6 ± 0.7 mm, angle of coronal plane 55.9° ± 1.3° and 50.7° ± 1.5°, angle of sagittal plane 26.7° ± 0.5° and 24.1° ± 0.9° and angle of horizontal plane 64.8° ± 0.6° and 58.8° ± 0.8°. In the comparison between female and male in each group, differences in distances between screws and anterior inferior iliac spine and median line of symphysis pubis (P > 0.05) were not statistically significant; differences in the remaining parameters were statistically significant (P < 0.05). Conclusions If surgeons paid attention to sex differences, select screws of appropriate diameter and length and hold the insertion position and direction, screws in the anterior pelvic ring fixation system could be safely inserted.
Collapse
Affiliation(s)
- Lin Liu
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, People's Republic of China.
| | - Shicai Fan
- The Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| | - Donggui Zeng
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, People's Republic of China
| | - Hui Song
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, People's Republic of China
| | - Letian Zeng
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, People's Republic of China
| | - Xiangyuan Wen
- The Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| | - Dadi Jin
- The Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| |
Collapse
|
15
|
Chen CH, Lien FC. Subcutaneous anterior pelvic bridge — an innovative technique for fixation of selective acetabular fracture: a case series and literature review. INTERNATIONAL ORTHOPAEDICS 2022; 46:1863-1872. [PMID: 35674913 PMCID: PMC9174027 DOI: 10.1007/s00264-022-05460-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Accepted: 05/25/2022] [Indexed: 11/28/2022]
Abstract
Introduction The aim of the study was to introduce an innovative technique involving the use of a subcutaneous anterior pelvic bridge (SAPB) in the treatment of selective acetabular fractures. Methods We performed a retrospective study of 21 patients with acetabular fracture who were treated with SAPB between January 2016 and March 2021. The patients’ data were retrieved from electronic charts. Radiological results were evaluated according to the Matta system to assess the quality of the reduction and time of union. Functional outcomes were assessed in line with the d’Aubigné and Postel scoring system. Post-operative complications were also recorded. Results SAPB required around 60 minutes, with minimal blood loss and short learning curve. Matta score revealed excellent radiological outcomes in seventeen displaced fractures with seven excellent outcomes and nine good outcomes. Functional outcomes were excellent in twelve hips, good in seven hips, and fair in two hips. Six patients had transient lateral femoral cutaneous nerve palsy. Discussion The innovative SAPB method for the treatment of selective acetabular fracture is proven to be a feasible method with promising outcomes. SAPB is a minimally invasive technique and strengthens the stability of fixation, with less blood loss and fewer intra-operative/post-operative complications.
Collapse
Affiliation(s)
- Chien Han Chen
- Present Address: Department of Neurosurgery, Chung Shan Medical University Hospital, 402 Taichung, Taiwan
| | - Fang Chieh Lien
- Department of Orthopedics, Ditmanson Medical Foundation Chia-Yi Christian Hospital, 600 Chiayi, Taiwan
| |
Collapse
|
16
|
Patel S, Aggarwal S, Jindal K, Kumar V, Sharma S. Outcomes and complications of the INFIX technique for unstable pelvic ring injuries with high-velocity trauma: a systematic review and meta-analysis. Arch Orthop Trauma Surg 2022; 142:787-803. [PMID: 33426606 DOI: 10.1007/s00402-020-03742-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Accepted: 12/19/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND The pelvic INFIX technique has been proposed as a useful alternative to symphyseal plating for management of unstable pelvic ring injuries. The minimally invasive nature of the procedure, shorter operative time and less perioperative blood loss have been purported as potential advantages. QUESTIONS/PURPOSES This systematic review and meta-analysis were conducted to determine the outcomes and complications of the INFIX technique for unstable pelvic ring injuries. METHODS A systematic review of literature was performed on the PubMed, EMBASE and Scopus databases. Prospective and retrospective studies in all languages, whether comparative or non-comparative, pertaining to the use of INFIX in pelvic fractures were included. Studies which did not evaluate INFIX, case reports, conference abstracts and those with less than 10 cases were excluded. Cadaveric studies, technique papers and studies that did not describe the prespecified outcome measures were also excluded. Meta-analysis consisted of two different arms: a comparative arm, to compare INFIX to symphyseal plating, and a non-comparative meta-analysis arm, to determine pooled rates of outcomes and complications. Risk of bias was determined by the Methodological Index for Non-Randomised Studies (MINORS) tool. RESULTS A total of 22 studies were included in the systematic review, of which 7 were comparative and 15 were non-comparative. 746 patients were included for qualitative analysis and pooled analysis done for 589 patients. The average follow-up of these studies ranged from a minimum of 5.4 months to a maximum of 54 months. Comparative meta-analysis (n = 3 studies) of plating and INFIX showed significantly lesser blood loss (mean difference = 176.46 mL; 95% CI - 207.54 to - 145.38) and shorter operative time (mean difference = 26.43 min, 95% CI - 31.79 to - 21.07) with INFIX, but no significant difference in the overall complication rates (OR 1.59, 95% CI 0.83-3.05) and functional outcome scores (mean difference = - 2.51, 95% CI - 5.73 to 0.71). Pooled analysis showed overall good radiological (mean percentage of excellent to good reduction = 91.4%, 95% CI 0.860-0.969) and functional outcomes (mean Majeed score = 86.48, 95% CI 83.34-89.61) with INFIX. The most common complications were lateral femoral cutaneous nerve (LFCN) injury (overall rate 28%, 95% CI 15.1-41%) and heterotopic ossification (HO) (overall rate 9.4%, 95% CI 5.5-13.3%); rates of other complications were low. Significant heterogeneity was noted in the pooled analysis of blood loss, operative time, functional outcome, HO and LFCN injury. The overall strength of evidence was found to be weak. CONCLUSION The INFIX technique can be considered as a viable alternative to symphyseal plating for unstable pelvic ring injuries. It has the advantages of shorter operative times and less blood loss, along with comparable functional outcomes, when compared to plating. Overall, good functional outcomes can be expected. However, well-designed, multi-center randomized controlled trials are needed to conclusively prove the benefit of this technique.
Collapse
Affiliation(s)
- Sandeep Patel
- Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - Sameer Aggarwal
- Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - Karan Jindal
- Post Graduate Institute of Medical Education and Research, Chandigarh, India.
| | - Vishal Kumar
- Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - Siddhartha Sharma
- Post Graduate Institute of Medical Education and Research, Chandigarh, India
| |
Collapse
|
17
|
Poole WEC, Neilly DW, Rickman MS. Is unrestricted weight bearing immediately after fixation of rotationally unstable pelvic fractures safe? BMC Musculoskelet Disord 2022; 23:348. [PMID: 35410267 PMCID: PMC8996606 DOI: 10.1186/s12891-022-05299-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 03/23/2022] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION Rotationally unstable pelvic fractures treated with surgical fixation have traditionally been treated with restricted weight bearing on the affected side for 6-8 weeks post operatively. We have been developing pelvic fixation standards to allow for unrestricted weight bearing immediately post operatively in type B rotationally unstable pelvic fractures. AIMS To assess for safety and efficacy of allowing unrestrictive weight bearing in this cohort of patients, we have clinically and radiologically monitored outcomes up to two years post operatively. METHODS Through retrospective review, two cohorts of patients with Tile Type B pelvic fractures were identified that were treated at the Royal Adelaide Hospital, South Australia. Patient demographics, injury classification, surgical fixation and weight bearing status post operatively was recorded. One cohort of patients was allowed to fully weight bear post operatively, whilst the other was treated with 6 weeks of restricted post op weight bearing. At clinical follow up, post-operative x-rays were assessed for loss of reduction, screw or plate breakage and reoperation. RESULTS Between January 2018 and January 2021, 53 patients with rotationally unstable pelvic fractures that underwent surgical fixation were included in this study. One group of patents were allowed to immediately weight bear as tolerated (WBAT) post operatively (n = 28) and the other with restricted weightbearing (RWB) (n = 25). There was 1 re operation for failure of fixation in each group. Metalwork breakage was more common in the WBAT group than in the RWB group and this was seen only in APC fractures. This increase in metalwork failure was not associated with loss of reduction. CONCLUSIONS With surgical fixation, Tile type B rotationally unstable pelvic fractures can be allowed immediate weight bearing post operatively. We found this to be safe and effective, employing surgical strategies to address both anterior and posterior injuries to allow immediate unrestricted weight bearing. Broken metalwork was more commonly seen in the WBAT group but this was not associated with loss of reduction or reoperation.
Collapse
Affiliation(s)
- William E C Poole
- Orthopaedic Trauma Department, Royal Adelaide Hospital, Adelaide, Australia.
| | - David W Neilly
- Orthopaedic Trauma Department, Royal Adelaide Hospital, Adelaide, Australia
| | - Mark S Rickman
- Orthopaedic Trauma Department, Royal Adelaide Hospital, Adelaide, Australia.,Trauma & Orthopaedics, University of Adelaide, Adelaide, Australia
| |
Collapse
|
18
|
Forward D, Vaidya R, Buckley R. To infix or not to infix an unstable pelvic injury. Injury 2022; 53:215-217. [PMID: 34986980 DOI: 10.1016/j.injury.2021.12.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Affiliation(s)
- Daren Forward
- Orthopedic Trauma Surgeon, Department of Orthopedic Trauma, Nottingham University Hospitals, Nottingham, UK
| | - Rahul Vaidya
- Chief of Orthopedic Trauma, Detroit Medical Center, Professor of Orthopedics, Wayne State University, 9B University Health Center, Detroit Receiving Hospital, 4201 St. Antoine Boulevard, Detroit, MI, 48201 United States
| | - Richard Buckley
- Professor of Orthopedics, 0490 McCaig Tower, Foothills Medical Center 3134 Hospital Dr NW Calgary, Alberta, T2N 5A1 Canada.
| |
Collapse
|
19
|
Liu L, Fan S, Zeng D, Chen Y, Song H, Zeng L, Jin D. Clinical application of anterior ring internal fixator system combined with sacroiliac screw fixation in Tile C pelvic fracture treatment. J Orthop Surg Res 2021; 16:715. [PMID: 34906168 PMCID: PMC8670052 DOI: 10.1186/s13018-021-02863-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Accepted: 12/01/2021] [Indexed: 11/17/2022] Open
Abstract
Background How to perform minimally invasive surgery for Tile C pelvic fracture is a major problem in clinical practice. We performed minimally invasive surgery for Tile C pelvic fracture using anterior ring internal fixator systems combined with sacroiliac screw fixation.
Objective To investigate the advantages and efficacy of anterior ring internal fixator systems combined with sacroiliac screw fixation in the treatment of Tile C pelvic fracture. Methods From May 2017 to May 2020, 27 patients with Tile C pelvic fracture who underwent anterior ring internal fixator system combined with sacroiliac screw fixation (group A) and 21 patients with Tile C pelvic fracture who underwent plate-screw system combined with sacroiliac screw fixation (group B) were retrospectively analyzed. Results All 48 patients were followed up for more than 12 months, all fractures healed within 3–6 months. The operative time, intraoperative bleeding volume, blood transfusion volume, incision length, hospital stay, complication rate and Majeed score were 63.5 ± 10.7 min, 48.3 ± 27.9 ml, 0 ml, 4.5 ± 0.8 cm, 10.2 ± 2.7 d, 3.7% and 89.7 ± 4.6 points, respectively, in group A and 114.8 ± 19.1 min, 375 ± 315.8 ml, 266.7 ± 326.6 ml, 9.2 ± 3.9 cm, 20.9 ± 5.7 d, 23.8% and 88.7 ± 4.9 points, respectively, in group B. Combined excellent and good rates of the Matta evaluation and Majeed score were 100% in both groups. There were no significant differences in the Matta evaluation or Majeed score between the two groups (both P > 0.05), whereas the operative time, intraoperative bleeding volume, blood transfusion volume, incision length and hospital stay were significantly less in group A (all P < 0.05). Conclusion An anterior ring internal fixator system combined with sacroiliac screw fixation can effectively treat Tile C pelvic fracture, and has advantages, including minimal invasiveness, simple operation, short operative time, safe and reliable features, fewer complications, short hospital stay and a good curative effect.
Collapse
Affiliation(s)
- Lin Liu
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, People's Republic of China.
| | - Shicai Fan
- The Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| | - Donggui Zeng
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, People's Republic of China
| | - Yuhui Chen
- The Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| | - Hui Song
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, People's Republic of China
| | - Letian Zeng
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, People's Republic of China
| | - Dadi Jin
- The Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| |
Collapse
|
20
|
Is Anterior Plating Superior to the Bilateral Use of Retrograde Transpubic Screws for Treatment of Straddle Pelvic Ring Fractures? A Biomechanical Investigation. J Clin Med 2021; 10:jcm10215049. [PMID: 34768569 PMCID: PMC8585079 DOI: 10.3390/jcm10215049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2021] [Revised: 10/17/2021] [Accepted: 10/26/2021] [Indexed: 11/22/2022] Open
Abstract
Background: Fractures of the four anterior pubic rami are described as “straddle fractures”. The aim of this study was to compare biomechanical anterior plating (group 1) versus the bilateral use of retrograde transpubic screws (group 2). Methods: A straddle fracture was simulated in 16 artificial pelvises. All specimens were tested under progressively increasing cyclic loading, with monitoring by means of motion tracking. Results: Axial stiffness did not differ significantly between the groups, p = 0.88. Fracture displacement after 1000–4000 cycles was not significantly different between the groups, p ≥ 0.38; however, after 5000 cycles it was significantly less in the retrograde transpubic screw group compared to the anterior plating group, p = 0.04. No significantly different flexural rotations were detected between the groups, p ≥ 0.32. Moreover, no significant differences were detected between the groups with respect to their cycles to failure and failure loads, p = 0.14. Conclusion: The results of this biomechanical study reveal less fracture displacement in the retrograde transpubic screw group after long-term testing with no further significant difference between anterior plating and bilateral use of retrograde transpubic screws. While the open approach using anterior plating allows for better visualization of the fracture site and open reduction, the use of bilateral retrograde transpubic screws, splinting the fracture, presents a minimally invasive and biomechanically stable technique.
Collapse
|
21
|
Anatomical Considerations in Percutaneous Fixation of the Pelvis and Acetabulum. J Am Acad Orthop Surg 2021; 29:811-819. [PMID: 34478415 DOI: 10.5435/jaaos-d-21-00066] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 05/03/2021] [Indexed: 02/01/2023] Open
Abstract
Reduction and fixation techniques of the pelvis and acetabulum continue to evolve. There has been increased use of percutaneous and minimally invasive techniques in the past several decades. Although offering many advantages to traditional open techniques, percutaneous techniques still place nearby structures at risk, making a thorough understanding of the applied surgical anatomy essential.
Collapse
|
22
|
Pan ZH, Chen FC, Huang JM, Sun CY, Ding SL. Modified pedicle screw-rod versus anterior subcutaneous internal pelvic fixation for unstable anterior pelvic ring fracture: a retrospective study and finite element analysis. J Orthop Surg Res 2021; 16:467. [PMID: 34315524 PMCID: PMC8314600 DOI: 10.1186/s13018-021-02618-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 07/13/2021] [Indexed: 11/24/2022] Open
Abstract
Objectives This study compared the stability and clinical outcomes of modified pedicle screw-rod fixation (MPSRF) and anterior subcutaneous internal pelvic fixation (INFIX) for the treatment of anterior pelvic ring fractures using the Tornetta and Matta grading system and finite element analyses (FEA). Methods In a retrospective review of a consecutive patient series, 63 patients with Orthopaedic Trauma Association (OTA)/Arbeitsgemeinschaft für Osteosynthesefragen (AO) type B or C pelvic ring fractures were treated by MPRSF (n = 30) or INFIX (n = 33). The main outcome measures were the Majeed score, incidence of complications, and adverse outcomes, and fixation stability as evaluated by finite element analysis. Results Sixty-three patients were included in the study, with an average age of 34.4 and 36.2 in modified group and conventional group, respectively. Two groups did not differ in terms of the injury severity score, OTA classification, cause of injury, and time to pelvic surgery. However, the MPSRF group had a rate of higher satisfactory results according to the Tornetta and Matta grading system than the conventional group (73.33% vs 63.63%) as well as a higher Majeed score (81.5 ± 10.4 vs 76.3 ± 11.2), and these differences were statistically significant at 6 months post-surgery. FEA showed that MPSRF was stiffer and more stable than INFIX and had a lower risk of implant failure. Conclusions Both MPSRF and INFIX provide acceptable biomechanical stability for the treatment of unstable anterior pelvic ring fractures. However, MPSRF provides better fixation stability and a lower risk of implant failure, and can thus lead to better clinical outcomes. Therefore, MPSRF should be more widely applied to anterior pelvic ring fractures Supplementary Information The online version contains supplementary material available at 10.1186/s13018-021-02618-9.
Collapse
Affiliation(s)
- Zhi-Hong Pan
- Zhoujiadu Community Health Service Center, Pudong New Area, Shanghai, 200126, People's Republic of China
| | - Fan-Cheng Chen
- Department of Orthopaedic Surgery, Zhongshan Hospital, Fudan University, Shanghai, 200032, People's Republic of China
| | - Jun-Ming Huang
- Department of Orthopaedic Surgery, Zhongshan Hospital, Fudan University, Shanghai, 200032, People's Republic of China
| | - Cheng-Yi Sun
- Department of Foot Ankle Surgery Beijing Tongren Hospital, Capital Medical University, No. 1, Dongjiaomin Lane, DongCheng District, Beijing, 100730, People's Republic of China
| | - Sheng-Long Ding
- Department of Foot Ankle Surgery Beijing Tongren Hospital, Capital Medical University, No. 1, Dongjiaomin Lane, DongCheng District, Beijing, 100730, People's Republic of China.
| |
Collapse
|
23
|
Abstract
OBJECTIVE To investigate the biomechanical performance of different size and length retrograde superior ramus screws. MATERIALS AND METHODS A vertical superior ramus fracture was created in osteoporotic composite hemipelvis bone models (Sawbones, Vashon Island, WA). After reduction, 4 fixation groups were created by inserting either a solid 4.5 mm (Depuy Synthes, Paoli, PA) or cannulated 7.0 mm screw (Zimmer, Warsaw, IN) of either 80 mm (short) or 140 mm (long) in length. An intact and an unstabilized osteotomy group were also created. Samples underwent cyclic loading for 5000 cycles with data acquisition at regular intervals. At the end of cyclic loading, load to failure was performed. RESULTS The displacement after 5000 cycles for 4.5 mm short screws was significantly greater than 4.5 mm long and 7.0 mm short screws. At 5000 cycles, the 4.5-mm short screws had a significantly lower stiffness and lower load to failure than all other screws and were not different from the osteotomy model. CONCLUSIONS Short 4.5-mm screws demonstrated increased displacement, lower stiffness, and decreased load to failure compared with all other screws. The biomechanical performance of 4.5-mm short screws was no different than unstabilized controls. Longer bicortical screw fixation is suggested when possible. Additional biomechanical and clinical studies are needed to fully understand the significance of these findings.
Collapse
|
24
|
Liu L, Zeng D, Fan S, Peng Y, Song H, Jin D, Zeng L. Biomechanical study of Tile C3 pelvic fracture fixation using an anterior internal system combined with sacroiliac screws. J Orthop Surg Res 2021; 16:225. [PMID: 33773576 PMCID: PMC8004429 DOI: 10.1186/s13018-021-02348-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Accepted: 03/10/2021] [Indexed: 01/13/2023] Open
Abstract
Background How to perform minimally-invasive surgery on Tile C pelvic fractures is very difficult, and it is also a hot topic in orthopedic trauma research. We applied minimally-invasive treatment using an anterior internal fixator combined with sacroiliac screws. Objectives To compare the biomechanical properties of different fixation models in pelvic facture specimens, using an internal fixation system or a steel plate combined with sacroiliac screws. Methods Sixteen fresh adult cadaver pelvic specimens were randomly separated into four groups named A, B, C, and D. The four groups were respectively stabilized using a two-screwed, three-screwed, or four-screwed anterior internal fixator or a steel plate with sacroiliac screws. All models were tested in both standing and sitting positions. Vertical loads of 600 N were applied increasingly. Shifts of bilateral sacroiliac joints and pubis rupture were measured. Results The shifts in sacroiliac joints and pubis rupture in the standing position were all less than 3.5 mm, and the shifts in the sitting position were all less than 1 mm. In the standing position, the results of shifts in the sacroiliac joints were group C < group D < group B < group A. For comparisons between A:B and C:D, P > 0.05. For comparisons between A, B:C, and D, P < 0.05. The results of shifts in pubis ruptures were group D < group C < group B < group A. In the comparison between C:D, P > 0.05; for comparisons between A:B, A:C, A:D, B:C, and B:D, P < 0.05. In the sitting posture, the results of shifts in the sacroiliac joints were group C < group D < group B < group A, and the shifts in the pubis ruptures were group D < group C < roup B < group A. For comparison between C:D, P > 0.05. For comparisons between A:B, A:C, A:D, B:C, and B:D, P < 0.05. Conclusion Use of an anterior internal fixator combined with sacroiliac screws effectively stabilized Tile C3 pelvic fractures. The stability of specimens increased as the number of screws in the internal fixator increased.
Collapse
Affiliation(s)
- Lin Liu
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Guangdong, Shenzhen, People's Republic of China.
| | - Donggui Zeng
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Guangdong, Shenzhen, People's Republic of China
| | - Shicai Fan
- The Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| | - Yongxing Peng
- The Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| | - Hui Song
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Guangdong, Shenzhen, People's Republic of China
| | - Dadi Jin
- The Third Affiliated Hospital, Southern Medical University, Guangzhou, Guangdong, People's Republic of China
| | - Letian Zeng
- Orthopedic Trauma, University of Chinese Academy of Sciences Shenzhen Hospital, Guangdong, Shenzhen, People's Republic of China
| |
Collapse
|
25
|
Russ MK, Navarre P, Stevens JP. An Alternative Site for Pin Placement in External Fixation of Pelvic Fractures: Lateral Posterior Pelvic External Fixator Surgical Technique. Front Surg 2021; 7:621125. [PMID: 33585549 PMCID: PMC7876391 DOI: 10.3389/fsurg.2020.621125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Accepted: 12/14/2020] [Indexed: 11/13/2022] Open
Abstract
Introduction: The application of an external fixator for unstable pelvic fractures is an important component of many resuscitation protocols. Moreover, certain pelvic fractures may be treated with an external fixator without requiring further internal fixation. We report our initial clinical results with an alternate pelvic external fixator site, the lateral posterior external fixator (LPEF), and describe the surgical technique. Methods and Materials: From 2010 to 2013, we identified 27 consecutive patients (mean age 44.6 years, range 18–80 years) treated by the same surgeon (MKR) with an LPEF in a level 1 trauma center. Retrospective data collection included mechanism of injury, surgical interventions, and complications. Results: The LPEF was used in 16 patients as acute pelvic stabilization and converted at a median of 2 days (interquartile range 1–3.5) to internal fixation, whereas in 10 patients, it was used as definitive treatment and removed at a median of 48 days (interquartile range 37–64). One patient died on day 14, secondary to his severe closed head injury. The only surgical complications were two wound infections (20%, 2/10 in the group of definitive LPEFs), which resolved without sequelae after the removal of the LPEF (at 36 and 50 days) and antibiotics, one case of loss of fixation leading to the removal of the LPEF at 71 days, and one patient who had hypergranulating external fixator sites and eventually healed without any cutaneous sequelae. All fractures consolidated in a good position. Discussion: The described techniques of pelvic external fixation include the anterosuperior (iliac wing), supra-acetabular (anteroinferior), and subcristal (anterior superior iliac spine) insertion sites. The reported infection rates in definitive pelvic fracture treatment range from 20 to 40%. Due to the localization of the insertion sites, the lateral femoral cutaneous nerve is potentially at risk with the last two techniques. On the other hand, the LPEF insertion site is quite safe, as it is anatomically far from any nerves and the inguinal region, and allows easy access for laparotomy. The results in this series suggest that the lateral posterior pelvic external fixator technique is an alternative to previous techniques with a low risk of complications.
Collapse
Affiliation(s)
- Matthias K Russ
- Department of Orthopaedic Surgery, Alfred Hospital, Melbourne, VIC, Australia.,Cabrini Hospital, Orthopaedic Surgery, Melbourne, VIC, Australia.,Department of Surgery, Monash University, Melbourne, VIC, Australia
| | - Pierre Navarre
- Department of Orthopaedic Surgery, Alfred Hospital, Melbourne, VIC, Australia.,Department of Orthopaedic Surgery, Southland Hospital, Invercargill, New Zealand.,Department of Surgical Sciences, University of Otago, Dunedin, New Zealand
| | - Jarrad P Stevens
- Department of Orthopaedic Surgery, Alfred Hospital, Melbourne, VIC, Australia.,Knox Orthopaedic Group, Knox Private Hospital, Melbourne, VIC, Australia
| |
Collapse
|
26
|
Sun X, Yan H, Wang J, Liu Z, Tian W, Jia J. Clinical research on minimally invasive internal fixation for the treatment of anterior ring injury in tile C pelvic fracture. Medicine (Baltimore) 2020; 99:e20652. [PMID: 32791662 PMCID: PMC7386985 DOI: 10.1097/md.0000000000020652] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
The aim of this study is to explore the clinical outcome and indications in treating anterior ring injury of Tile C pelvic fracture with minimally invasive internal fixation.We retrospectively reviewed 18 patients (aged 25-62, 34.2 ± 7.4) with 26 pelvic anterior ring injuries of Tile C pelvic fracture treated with minimally invasive internal fixation in our hospital were from January 2012 to August 2016. Two cases were pubic symphysis diastasis, 15 were anterior ring fracture (7 were bilateral), and 1 was vertical displacement of pubic symphysis associated with pubic ramus fracture. According to Tile classification, 8, 4, and 6 cases were types C1, C2, and C3, respectively. All patients accepted the operation of pelvic fractures on both rings, while the anterior ring injuries were treated with minimally invasive internal fixation. The period from injury to operation was 5 to 32 days (11.2 ± 3.7). Four patients had pubic symphysis diastasis or pelvic anterior ring fracture medial obturator foramen reduced with modified Pfannenstiel incision and fixed with cannulated screws, 14 patients (22 fractures) had a fractured lateral obturator foramen reduced with modified Pfannenstiel incision associated with small iliac crest incision and fixed with locking reconstruction plates. Clinical data, such as operation time, intraoperative bleeding, Matta standard to assess the reduction quality of fracture, and complications, were collected and analyzed.The operation time ranged from 30 to 65 minutes (42.8 ± 18.7), and the intraoperative bleeding volume was 30 to 150 mL (66.5 ± 22.8). All cases were continuously followed-up for 16 to 42 months (30.2 ± 4.6). All fractures were healed between 3 and 9 months postoperatively (4.9 ± 2.7 months). According to the Matta standard assessment, 18, 7, and 1 cases were excellent, good, and fair, respectively, with a 96.2% (25/26) rate of satisfaction. Neither reduction loss, fixation failure, nor infection occurred; complications included 1 patient with fatal liquefaction, 1 patient had lateral femoral cutaneous nerve injury, and 1 patient complained of discomfort in the inguinal area due to fixation stimulation.Minimally invasive internal fixation for pelvic anterior ring injury in Tile C pelvic fracture has the advantages of less damage, safer manipulation, less complications, and good prognosis.
Collapse
Affiliation(s)
- Xiaochen Sun
- Department of Orthopaedic Surgery, Tianjin Haihe Hospital
| | - Huimin Yan
- Department of Orthopaedic Surgery, Tianjin Haihe Hospital
| | - Jianmin Wang
- Department of Orthopaedic Surgery, Da Feng Tong Ren hospital of Yancheng, Jiangsu
| | - Zhaojie Liu
- Department of Orthopaedic Surgery, Tianjin Hospital, Tianjin, China
| | - Wei Tian
- Department of Orthopaedic Surgery, Tianjin Hospital, Tianjin, China
| | - Jian Jia
- Department of Orthopaedic Surgery, Tianjin Hospital, Tianjin, China
| |
Collapse
|
27
|
|
28
|
Wu G, Tan L, Li B, Zhang C, Zhang Z. [Comparison study of minimally invasive percutaneous bridge internal fixator and traditional external fixator in treatment of unstable pelvic fractures]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2020; 34:563-568. [PMID: 32410421 DOI: 10.7507/1002-1892.201907054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To evaluate the effectiveness of unstable pelvic fractures treated with minimally invasive percutaneous bridge internal fixator or traditional external fixator. Methods The clinical data of 45 patients with unstable pelvic fractures who met the selection criteria between January 2013 and February 2018 were retrospectively analyzed. According to the different surgical methods, they were divided into two groups. In the observation group (25 cases), minimally invasive percutaneous bridge internal fixators were used, and three-dimensional printing pelvic models were used to simulate the reduction and fixation before operation to develop individual reduction strategies. In the control group (20 cases), external fixators were used. There was no significant difference between the two groups in gender, age, cause of injury, fracture type (according to Tile classification), and time from injury to operation ( P>0.05). The operation time, intraoperative blood loss, fracture healing time, and complications were recorded and compared between the two groups. The reduction quality was evaluated according to the Matta standard, and functional recovery was evaluated according to the Majeed scoring standard. Results All patients were followed up 12-20 months (mean, 15 months). The operation time of the observation group was significantly longer than that of the control group ( t=2.719, P=0.009); no significant difference in intraoperative blood loss was found between the two groups ( t=0.784, P=0.437). There was no significant difference between the two groups in fracture healing time ( t=0.967, P=0.341). According to the Matta standard, the excellent and good rate of the observation group was 92%, and that of the control group was 70%, showing no significant difference between the two groups ( χ 2 =3.748, P=0.053). At last follow-up, according to the Majeed scoring standard, the excellent and good rate of the observation group was 88%, and that of the control group was 60%, showing significant difference between the two groups ( χ 2 =4.717, P=0.030). The incidences of incision and nailway infection, secondary displacement of fracture, and malunion in the observation group were significantly lower than those in the control group ( P<0.05); the differences in incidences of iatrogenic injury of lateral femoral cutaneous nerve, deep vein thrombosis, and loosening of fixation between the two groups were not significant ( P>0.05). Conclusion Minimally invasive percutaneous bridge internal fixator is a safe and effective method for the treatment of unstable pelvic fractures. It has the advantages of minimal trauma, stable fixation, less interference to patients' daily life, early functional exercise, and quickly recovery after operation.
Collapse
Affiliation(s)
- Gang Wu
- Department of Orthopaedics, The 4th People's Hospital of Zigong, Zigong Sichuan, 643000, P.R.China
| | - Lun Tan
- Department of Orthopaedics, The 4th People's Hospital of Zigong, Zigong Sichuan, 643000, P.R.China
| | - Bangqing Li
- Department of Orthopaedics, The 4th People's Hospital of Zigong, Zigong Sichuan, 643000, P.R.China
| | - Caidong Zhang
- Department of Orthopaedics, The 4th People's Hospital of Zigong, Zigong Sichuan, 643000, P.R.China
| | - Zhiwei Zhang
- Department of Orthopaedics, The 4th People's Hospital of Zigong, Zigong Sichuan, 643000, P.R.China
| |
Collapse
|
29
|
武 建, 师 政, 周 建, 潘 奕, 李 邵, 汪 玉. [Research progress on minimally invasive treatment of anterior pelvic ring fracture]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2020; 34:529-535. [PMID: 32291994 PMCID: PMC8171507 DOI: 10.7507/1002-1892.201907077] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 01/24/2020] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To summarize the related research results of minimally invasive treatment of anterior pelvic ring fracture, and to improve the understanding of minimally invasive treatment of anterior pelvic ring fracture. METHODS The literature of minimally invasive treatment of anterior pelvic ring fracture at domestic and overseas in recent years was reviewed, and the reduction and fixation methods of minimally invasive treatment were summarized and analyzed. RESULTS The pelvic reduction frame may be an effective auxiliary method for minimally invasive reduction of pelvis. The fixation methods of anterior pelvic ring include percutaneous screw fixation, stent fixation, and percutaneous plate fixation. CONCLUSION One kind of fixation is not applicable to all types of anterior pelvic ring fracture, and the fixation method should be selected according to the type of fracture and the patient's condition to minimize the complications.
Collapse
Affiliation(s)
- 建超 武
- 兰州大学第二医院骨科(兰州 730030)Department of Orthopedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou Gansu, 730030, P.R.China
| | - 政伟 师
- 兰州大学第二医院骨科(兰州 730030)Department of Orthopedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou Gansu, 730030, P.R.China
| | - 建伟 周
- 兰州大学第二医院骨科(兰州 730030)Department of Orthopedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou Gansu, 730030, P.R.China
| | - 奕欣 潘
- 兰州大学第二医院骨科(兰州 730030)Department of Orthopedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou Gansu, 730030, P.R.China
| | - 邵平 李
- 兰州大学第二医院骨科(兰州 730030)Department of Orthopedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou Gansu, 730030, P.R.China
| | - 玉良 汪
- 兰州大学第二医院骨科(兰州 730030)Department of Orthopedics, the Second Affiliated Hospital of Lanzhou University, Lanzhou Gansu, 730030, P.R.China
| |
Collapse
|
30
|
Liu L, Fan S, Chen Y, Peng Y, Wen X, Zeng D, Song H, Jin D. Biomechanics of Anterior Ring Internal Fixation Combined with Sacroiliac Screw Fixation for Tile C3 Pelvic Fractures. Med Sci Monit 2020; 26:e915886. [PMID: 32163378 PMCID: PMC7092661 DOI: 10.12659/msm.915886] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Background Despite the development of minimally invasive techniques for pelvic fractures, performing minimally invasive surgery for Tile C3 pelvic fractures remains challenging. Thus, we propose use of anterior ring internal fixation combined with sacroiliac screw fixation for Tile C3 pelvic fractures. Material/Methods A normal pelvic finite element model (model 1) was established. Two-screw, three-screw, and four-screw anterior ring internal fixators and plate combined with sacroiliac screw Tile C3 pelvic fracture models (models 2, 3, 4, and 5, respectively) were also established. A vertical load of 600 N was applied on S1. The distribution of displacement and stress in the standing and sitting positions was compared. Results Models 2, 3, 4, and 5 can provide effective fixation. Compared with model 1, in the erect position, the maximum displacement of models 2, 3, 4, and 5 increased by 66.51%, 65.36%, 35.16%, and 35.47% and the maximum stress increased by 201.78%, 130.65%, 100.82%, and 99.03%, respectively. Compared with model 1, in sitting position, the maximum displacement of models 2, 3, 4, and 5 increased by 9.1%, 11.04%, 5.57%, and 8.59% and the maximum stress increased by 157.73%, 118.02%, 98.32%, and 93.16%, respectively. Conclusions Anterior ring internal fixators combined with sacroiliac screws can effectively fix Tile C3 pelvic fractures.
Collapse
Affiliation(s)
- Lin Liu
- Department of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland).,Department of Traumatic Orthopaedics, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, China (mainland)
| | - Shicai Fan
- Department of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland)
| | - Yuhui Chen
- Department of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland)
| | - Yongxing Peng
- Department of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland)
| | - Xiangyuan Wen
- Department of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland)
| | - Donggui Zeng
- Department of Traumatic Orthopaedics, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, China (mainland)
| | - Hui Song
- Department of Traumatic Orthopaedics, University of Chinese Academy of Sciences Shenzhen Hospital, Shenzhen, Guangdong, China (mainland)
| | - Dadi Jin
- Department of Traumatic Orthopedics, The Third Affiliated Hospital, Southern Medical University, Guangzhuo, Guangdong, China (mainland)
| |
Collapse
|
31
|
Comparison of Biomechanical Performance of Five Different Treatment Approaches for Fixing Posterior Pelvic Ring Injury. JOURNAL OF HEALTHCARE ENGINEERING 2020; 2020:5379593. [PMID: 32076495 PMCID: PMC6996702 DOI: 10.1155/2020/5379593] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 11/18/2019] [Accepted: 01/06/2020] [Indexed: 12/03/2022]
Abstract
Background A large number of pelvic injuries are seriously unstable, with mortality rates reaching 19%. Approximately 60% of pelvic injuries are related to the posterior pelvic ring. However, the selection of a fixation method for a posterior pelvic ring injury remains a challenging problem for orthopedic surgeons. The aim of the present study is to investigate the biomechanical performance of five different fixation approaches for posterior pelvic ring injury and thus provide guidance on the choice of treatment approach in a clinical setting. Methods A finite element (FE) model, including the L3-L5 lumbar vertebrae, sacrum, and full pelvis, was created from CT images of a healthy adult. Tile B and Tile C types of pelvic fractures were created in the model. Five different fixation methods for fixing the posterior ring injury (PRI) were simulated: TA1 (conservative treatment), TA2 (S1 screw fixation), TA3 (S1 + S2 screw fixation), TA4 (plate fixation), and TA5 (modified triangular osteosynthesis). Based on the fixation status (fixed or nonfixed) of the anterior ring and the fixation method for PRI, 20 different FE models were created. An upright standing loading scenario was simulated, and the resultant displacements at the sacroiliac joint were compared between different models. Results When TA5 was applied, the resultant displacements at the sacroiliac joint were the smallest (1.5 mm, 1.6 mm, 1.6 mm, and 1.7 mm) for all the injury cases. The displacements induced by TA3 and TA2 were similar to those induced by TA5. TA4 led to larger displacements at the sacroiliac joint (2.3 mm, 2.4 mm, 4.8 mm, and 4.9 mm), and TA1 was the worst case (3.1 mm, 3.2 mm, 6.3 mm, and 6.5 mm). Conclusions The best internal fixation method for PRI is the triangular osteosynthesis approach (TA5), followed by S1 + S2 screw fixation (TA3), S1 screw fixation (TA2), and plate fixation (TA4).
Collapse
|
32
|
Vaidya R. Comment on: The use of anterior subcutaneous internal fixation (INFIX) for treatment of pelvic ring injuries in major trauma patients, complications and outcomes. SICOT J 2019; 5:36. [PMID: 31625887 PMCID: PMC6798727 DOI: 10.1051/sicotj/2019033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Accepted: 09/12/2019] [Indexed: 11/25/2022] Open
Affiliation(s)
- Rahul Vaidya
- Department of Orthopaedic Surgery, The DMC Heart Hospital, 311 Mack Avenue - 5th floor, Detroit, MI 48201, USA
| |
Collapse
|
33
|
Abstract
We describe the case of an 8-year old female patient with an open pelvic fracture after being run over by a bus. Open pelvic injuries in pediatric patients are very rare and are associated with high mortality rates and long-term morbidity. In this case, a multidisciplinary surgical approach is described. The injuries include a complex pelvic ring fracture, which was treated with an internal external fixator, together with severe urogenital and soft-tissue injury. The internal external fixator, a surgical technique involving a temporary internal fixation device, is well described in adults, but has not been described in pediatric patients before. This case presentation shows the severity and complexity of the treatment of open pelvic fractures with severe associated injures. Albeit the treatment of her orthopaedic injuries has been successful so far, our patient unfortunately still suffers notable morbidity from her other injuries.
Collapse
|
34
|
Modified internal fixator for anterior pelvic ring fractures versus conventional two-screw fixation. Eur J Trauma Emerg Surg 2019; 47:533-539. [PMID: 31147724 DOI: 10.1007/s00068-019-01164-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Accepted: 05/27/2019] [Indexed: 01/13/2023]
Abstract
PURPOSE The present study aims to evaluate the short-term clinical effects and complications of modified three-screw fixation and conventional two-screw fixation for treating anterior pelvic ring fractures. METHODS A retrospective study of 51 patients with type B fractures was performed. 25 patients (modified group) were treated with modified three-screw fixation and the other 26 patients (conventional group) with conventional two-screw fixation. Outcome measures included operation time, intraoperative blood loss, hospital stays, postoperative complications and the Majeed score at postoperatively 2 months, 3 months, 1 year and the time of implant removal. RESULTS The mean operative times and mean blood loss for modified three-screw fixation versus conventional two-screw fixation bilateral were 54.8 ± 10.7 min versus 32.3 ± 9.9 min, and 153.3 mL versus 550.0 mL (p < 0.001), respectively. However, the Majeed score was better in modified group at postoperatively 2 months (75.6 ± 9.5 vs. 69.7 ± 8.3, p = 0.008) and 3 months (80.3 ± 10.7 vs. 75.1 ± 11.9, p = 0.014). There was no statistical difference between two groups at the time of implant removal (82.1 ± 9.3 vs. 80.9 ± 8.8, p = 0.272) and postoperatively 1 year (83.5 ± 7.8 vs 82.6 ± 8.2, p = 0.723). No patients experienced surgical wound infection, deep vein thrombosis, delayed union or nonunion, implant loosening or rupture. One patient complained of tardive unilateral thigh pain at postoperatively 4 months in conventional group. CONCLUSIONS Both modified three-screw fixation and conventional two-screw fixation could ultimately afford satisfactory clinical and radiological outcomes with less complication for anterior pelvic ring fractures. The modified three-screw fixation might have better biomechanical strength and faster pelvic rehabilitation.
Collapse
|
35
|
Becker CA, Kammerlander C, Kußmaul AC, Woiczinski M, Thorwächter C, Zeckey C, Sommer F, Linhart C, Weidert S, Suero EM, Böcker W, Greiner A. Modified less invasive anterior subcutaneous fixator for unstable Tile-C-pelvic ring fractures: a biomechanical study. Biomed Eng Online 2019; 18:38. [PMID: 30925898 PMCID: PMC6441140 DOI: 10.1186/s12938-019-0648-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Accepted: 03/13/2019] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND Operative procedures for unstable pelvic ring fractures remain controversially discussed. Minimally invasive treatment options for pelvic ring fractures have several benefits for the patient. But they can also provide disadvantages. Anterior subcutaneous pelvic fixation (INFIX) has shown promising biomechanical results in pelvic ring fractures, but there is a high complication rate of nerve injuries. An additional screw to the INFIX seems to be more stable. The aim of this study is to compare biomechanical stability of a new modified unilateral INFIX fixing the unilateral injured pelvic ring with the standard INFIX. METHODS 24 composite synthetic full pelvises were used in this study. 4 groups each with a number of six pelvic specimens were randomly assigned. A C1.3-type pelvic fracture was made with an osteotomy of the sacrum and an osteotomy of the anterior pelvic ring. Fracture fixation was performed within the four groups: (1) unilateral INFIX, (2) "extended" unilateral INFIX + additional pubic ramus pedicle screw, (3) bilateral INFIX, (4) "extended" bilateral INFIX + additional pubic ramus pedicle screw. All specimens were cyclic loaded with 200 N until maximum of 300 N. Distance/dislocation of the fracture fragments were detected with 3D-ultrasound measuring system. Stiffness was calculated. RESULTS Extended unilateral INFIX showed the lowest mean dislocation. Lowest rotational stability was displayed by the standard bilateral INFIX. A significant difference (P = 0.04) was shown between the extended unilateral INFIX and the "standard" bilateral INFIX in terms of rotational stability. Extended unilateral INFIX showed significantly improved stability of anterior fracture dislocation (P = 0.01) and unilateral INFIX showed the highest rotational stiffness. Anterior fixation stiffness of the unilateral INFIX was significantly improved using an additional symphysis/pubic ramus screw (P = 0.002). CONCLUSION Extended unilateral INFIX (+ additional pubic ramus pedicle screw) is a feasible minimally invasive treatment for anterior pelvic ring fractures. Higher stability and lower probability of bilateral nerve damage is provided by the extended unilateral INFIX compared to the standard bilateral INFIX.
Collapse
Affiliation(s)
- Christopher A Becker
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Christian Kammerlander
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Adrian Cavalcanti Kußmaul
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Matthias Woiczinski
- Department of Orthopedics, Physical Medicine and Rehabilitation, University Hospital, LMU Munich, Munich, Germany
| | - Christoph Thorwächter
- Department of Orthopedics, Physical Medicine and Rehabilitation, University Hospital, LMU Munich, Munich, Germany
| | - Christian Zeckey
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Fabian Sommer
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Christoph Linhart
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Simon Weidert
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Eduardo M Suero
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Wolfgang Böcker
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany
| | - Axel Greiner
- Department of General Trauma & Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany.
| |
Collapse
|
36
|
Yin Y, Luo J, Zhang R, Li S, Jiao Z, Zhang Y, Hou Z. Anterior subcutaneous internal fixator (INFIX) versus plate fixation for pelvic anterior ring fracture. Sci Rep 2019; 9:2578. [PMID: 30796253 PMCID: PMC6385294 DOI: 10.1038/s41598-019-39068-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Accepted: 01/16/2019] [Indexed: 01/13/2023] Open
Abstract
The aim of this study was to compare the clinical outcomes in patients with unstable anterior pelvic ring fractures after treatment with anterior subcutaneous internal fixator (INFIX) or plate fixation. We performed a retrospective study from August 2015 to October 2017. A consecutive series of 74 patients who underwent surgical treatment of their anterior pelvic ring (35 treated with INFIX and 39 treated with plates) were studied. Data collected included patients' demographic data, injury severity score (ISS), AO/OTA classification, injury mechanism, time to surgery, procedure time, and blood loss. The quality of postoperative reduction were assessed by postoperative radiographs using the Tornetta and Matta method. Functional outcome was evaluated using Majeed scoring system. In the INFIX group, ten patients developed LFCN paralysis, one patient suffered from superficial infection. Three screw loosening cases and two wound infection cases occurred in the plate group. INFIX is relatively minimally invasive and time-saving than the reconstruction plate in the treatment of anterior pelvic ring fracture. However, plate fixation increases the rate of anatomic reduction of the pelvic anterior ring fracture. Plates also provide a higher functional outcome compared with INFIX. INFIX is especially suitable in patients with urological injury, which can also decrease the wound infection rate.
Collapse
Affiliation(s)
- Yingchao Yin
- Department of Orthopaedic Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050051, P. R. China
- Key laboratory of biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, P. R. China
| | - Junhao Luo
- Department of Orthopaedic Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050051, P. R. China
- Key laboratory of biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, P. R. China
| | - Ruipeng Zhang
- Department of Orthopaedic Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050051, P. R. China
- Key laboratory of biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, P. R. China
| | - Shilun Li
- Department of Orthopaedic Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050051, P. R. China
- Key laboratory of biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, P. R. China
| | - Zhenqing Jiao
- Department of Orthopaedic Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050051, P. R. China
- Key laboratory of biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, P. R. China
| | - Yingze Zhang
- Department of Orthopaedic Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050051, P. R. China.
- Key laboratory of biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, P. R. China.
- Chinese Academy of Engineering, Beijing, 100088, P. R. China.
| | - Zhiyong Hou
- Department of Orthopaedic Surgery, the Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050051, P. R. China
- Key laboratory of biomechanics of Hebei Province, Shijiazhuang, Hebei, 050051, P. R. China
| |
Collapse
|
37
|
Stewart RG, Hammer N, Kieser DC. External fixation of unstable pelvic fractures: a systematic review and meta-analysis. ANZ J Surg 2019; 89:1022-1027. [PMID: 30756458 DOI: 10.1111/ans.15027] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Revised: 10/15/2018] [Accepted: 11/25/2018] [Indexed: 10/27/2022]
Abstract
BACKGROUND Unstable pelvic fractures are typically caused by high-impact trauma. Early stabilization is required to prevent further neurological or visceral injury, haemorrhage, reduce pain, infection and long-term deformity and disability. The aim was to review the optimal external fixation techniques and management for unstable pelvic fractures. METHODS A total of 28 studies were identified from the initial database search. Seventeen studies met our inclusion criteria - eight prospective cohorts, four retrospective cohorts and five in vitro studies. This equated to 539 patients and 38 cadaveric (in vitro) models. RESULTS Type B and double vertical fractures have less re-displacement (43.7% and 68.2% <5 mm, respectively) than Type C fractures (55.7% >15 mm) regardless of pin placement. Greater than 50% experience a complication with the most common being pin site infection (36%) and a trend towards increased infection with increasing pins was seen. Most can be managed with antibiotics alone (93%). A minimum time of 6-8 weeks in frame was required for definitive management of all fractures. CONCLUSION This review supports the use of supra-acetabular pins over iliac crest pins to decrease re-displacement, the least number of pins for the shortest amount of time and the largest size pin where possible. Type B fractures will generally have a better outcome than Type C fractures. Definitive management in a frame should be at least 8 weeks. Further studies directly comparing iliac crest and supra-acetabular pin placement are recommended.
Collapse
Affiliation(s)
- Rebecca G Stewart
- Department of Orthopaedic Surgery and MSM, University of Otago, Christchurch, New Zealand
| | - Niels Hammer
- Department of Anatomy, University of Otago, Dunedin, New Zealand.,Department of Orthopaedic and Trauma Surgery, University of Leipzig, Leipzig, Germany.,Fraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany
| | - David C Kieser
- Department of Orthopaedic Surgery and MSM, University of Otago, Christchurch, New Zealand
| |
Collapse
|
38
|
MacCormick LM, Chen F, Gilbertson J, Khan S, Schroder LK, Bechtold JE, Cole PA. A biomechanical study comparing minimally invasive anterior pelvic ring fixation techniques to external fixation. Injury 2019; 50:251-255. [PMID: 30447984 DOI: 10.1016/j.injury.2018.07.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Revised: 06/18/2018] [Accepted: 07/17/2018] [Indexed: 02/02/2023]
Abstract
INTRODUCTION INFIX and Pelvic Bridge are two new minimally invasive surgical techniques for unstable pelvic ring injuries, and they have demonstrated early clinical success in small, single-center case-series. The primary objective of this study is to gather evidence speaking to the biomechanical stability of internal bridging methods relative to external fixation, with the expectation of biomechanical equivalence. METHODS Ten human cadaveric pelvic specimens were dissected free of all skin, fat, organs, and musculature and were prepared with a partially unstable pelvic ring injury (OTA/AO 61-B). The specimens were randomized to two groups and were repaired and tested with anterior pelvic external fixation (APEF) and INFIX sequentially, or APEF and Pelvic Bridge sequentially. Testing was performed with each specimen mounted onto a servo-hydraulic testing frame with axial compression applied to the superior base of the sacrum under five axial loading/unloading sinusoidal cycles between 10 N and 1000 N at 0.1 Hz. Relative translational motion and rotation across the osteotomy site was reported as our primary outcome measures. Outcome measures were further analyzed using a Wilcoxon signed-rank test to determine differences between non-parametric data sets with significance defined as a p value < 0.05. RESULTS We found no statistical difference in translation (p = 0.237, 0.228) or rotation (p = 0.278, 0.873) at the fracture site when comparing both new constructs to external fixation. Under the imposed loading protocol, no episodes of implant failure or failure at the bone-implant interface occurred. DISCUSSION Our study provides the biomechanical foundation necessary to support future clinical trial implementation for pelvic fracture patients. While biomechanical stability of these newer, subcutaneous techniques is equivalent to APEF, the surgeon must take into account their technical abilities and knowledge of pelvic anatomy, patient-specific factors including body habitus, and the potential complications associated with each implant and the ability to avoid them.
Collapse
Affiliation(s)
- Lauren M MacCormick
- University of Minnesota, Department of Orthopaedic Surgery, 2512 S. 7th St., R200, Minneapolis, MN 55454, United States
| | - Frank Chen
- Excelen Center for Bone & Joint Research and Education, 700 10th Avenue South, Minneapolis, MN 55415, United States
| | - Jeff Gilbertson
- Regions Hospital, Department of Orthopaedic Surgery, 640 Jackson Street - MS 11503L, Saint Paul, MN 55101-2595, United States
| | - Sikandar Khan
- University of Minnesota, Department of Orthopaedic Surgery, 2512 S. 7th St., R200, Minneapolis, MN 55454, United States
| | - Lisa K Schroder
- Regions Hospital, Department of Orthopaedic Surgery, 640 Jackson Street - MS 11503L, Saint Paul, MN 55101-2595, United States
| | - Joan E Bechtold
- University of Minnesota, Department of Orthopaedic Surgery, 2512 S. 7th St., R200, Minneapolis, MN 55454, United States; Excelen Center for Bone & Joint Research and Education, 700 10th Avenue South, Minneapolis, MN 55415, United States
| | - Peter A Cole
- University of Minnesota, Department of Orthopaedic Surgery, 2512 S. 7th St., R200, Minneapolis, MN 55454, United States; Regions Hospital, Department of Orthopaedic Surgery, 640 Jackson Street - MS 11503L, Saint Paul, MN 55101-2595, United States.
| |
Collapse
|
39
|
Guerado E, Bertrand ML, Cano JR, Cerván AM, Galán A. Damage control orthopaedics: State of the art. World J Orthop 2019; 10:1-13. [PMID: 30705836 PMCID: PMC6354106 DOI: 10.5312/wjo.v10.i1.1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Revised: 12/11/2018] [Accepted: 12/13/2018] [Indexed: 02/06/2023] Open
Abstract
Damage control orthopaedics (DCO) originally consisted of the provisional immobilisation of long bone - mainly femur - fractures in order to achieve the advantages of early treatment and to minimise the risk of complications, such as major pain, fat embolism, clotting, pathological inflammatory response, severe haemorrhage triggering the lethal triad, and the traumatic effects of major surgery on a patient who is already traumatised (the “second hit” effect). In recent years, new locations have been added to the DCO concept, such as injuries to the pelvis, spine and upper limbs. Nonetheless, this concept has not yet been validated in well-designed prospective studies, and much controversy remains. Indeed, some researchers believe the indiscriminate application of DCO might be harmful and produce substantial and unnecessary expense. In this respect, too, normalised parameters associated with the acid-base system have been proposed, under a concept termed early appropriate care, in the view that this would enable patients to receive major surgical procedures in an approach offering the advantages of early total care together with the apparent safety of DCO. This paper discusses the diagnosis and treatment of severely traumatised patients managed in accordance with DCO and highlights the possible drawbacks of this treatment principle.
Collapse
Affiliation(s)
- Enrique Guerado
- Department of Orthopaedic Surgery and Traumatology, Hospital Costa del Sol, University of Malaga, Marbella 29603, Malaga, Spain
| | - Maria Luisa Bertrand
- Department of Orthopaedic Surgery and Traumatology, Hospital Costa del Sol, University of Malaga, Marbella 29603, Malaga, Spain
| | - Juan Ramon Cano
- Department of Orthopaedic Surgery and Traumatology, Hospital Costa del Sol, University of Malaga, Marbella 29603, Malaga, Spain
| | - Ana María Cerván
- Department of Orthopaedic Surgery and Traumatology, Hospital Costa del Sol, University of Malaga, Marbella 29603, Malaga, Spain
| | - Adolfo Galán
- Department of Orthopaedic Surgery and Traumatology, Hospital Costa del Sol, University of Malaga, Marbella 29603, Malaga, Spain
| |
Collapse
|
40
|
Digital Anatomy to Improve Screw Insertion Techniques for Plate-Screw Fixation of the Pubic Body. BIOMED RESEARCH INTERNATIONAL 2019; 2018:4690879. [PMID: 30643807 PMCID: PMC6311337 DOI: 10.1155/2018/4690879] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 10/21/2018] [Accepted: 11/12/2018] [Indexed: 11/17/2022]
Abstract
Objectives This study aims to investigate screw insertion sites on the pubic body and the safe screw insertion parameters of a plate-screw fixation system based on the premise of avoiding damage to the inguinal canal and disruption of the rectus abdominis at the pubic symphysis and pubic crest. Research Methods Excluding cases with poor image quality, tumors, malformations, and fractures, the data of 80 healthy adults (40 males and 40 females aged from 21 to 83 years old, with an average age of 51.65 years) undergoing a computed tomography (CT) scan of the pelvis between January and June of 2017 were collected from Shandong Provincial Hospital. The CT scans were imported to Mimics® software to reconstruct three-dimensional pelvic models. A 3.5 mm pelvic reconstruction plate was placed starting at the outer edge of the pubic tubercle and along the pelvic brim. The two innermost screw insertion sites were marked. The safe range for the screw insertion sites was then determined. The screw insertion plane was selected to measure the safe screw insertion parameters. The length of the screw, the direction of insertion, and intersex differences were then explored via statistical analyses. Results The medial inclination angles (MIAs) of the screw insertion plane for males and females were 30.42±7.95° and 32.88±10.65°, respectively, with no statistically significant differences. For the medial screw, the maximum anterior inclination angle (MAIA), the maximum screw length, and the maximum posterior inclination angle (MPIA) were 46.51±4.01°, 12.40±9.53 mm, and 11.78±10.22° on average, respectively, with no significant differences by gender (P>0.05). For the lateral screw, the MAIA was 10.35±9.46° and showed no gender differences (P>0.05), but the male group had a greater MPIA (male 11.80±11.00° vs. female 6.23±7.91°, P<0.05) and maximum screw length (male 55.71±6.36 mm vs. female 48.68±8.65, P<0.001). For the tangential screw, the maximum screw length, MIA, and anterior/posterior inclination angle (APIA) were 52.19±8.33 mm, 31.65±9.42°, and 7.53±10.18°, respectively, with no significant differences in the angles by gender (both P>0.05), although the screw length in the male group was significantly longer than that in the female group. Conclusions Insertion of two screws into the pubic body through a plate from the lateral side of the pubic tubercle is safe and can maintain the origin of the rectus abdominis and the integrity of the inguinal canal compared to traditional plate-screw fixation. Considering that the pubic body is thinner on the lateral side, we suggest a more medial inclination angle for the lateral screw.
Collapse
|
41
|
Ma L, Ma L, Chen Y, Jiang Y, Su Q, Wang Q, Zhu Y. A cost minimization analysis comparing minimally-invasive with open reduction surgical techniques for pelvic ring fracture. Exp Ther Med 2019; 17:1802-1812. [PMID: 30783452 PMCID: PMC6364252 DOI: 10.3892/etm.2019.7151] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Accepted: 12/14/2018] [Indexed: 12/24/2022] Open
Abstract
The aim of the present study was to compare the in-hospital direct medical costs of patients with pelvic fracture treated with minimally invasive surgery (MIS) or open reduction and internal fixation (ORIF). A retrospective, single-center, cohort, and comparative study was performed. Administrative information and clinical results, in addition to cost data, were collected and analyzed. A cost minimization analysis method was used to evaluate the costs of two different surgical techniques. A total of 128 patients diagnosed with pelvic fracture were included in this study; 62 were treated with MIS and 66 underwent ORIF. No significant difference was observed between the 2 groups in terms of patients' clinical baseline characteristics. The operative time, length of incision, intra-operative blood loss, and post-operative length of stay in the MIS group were significantly different compared with those in the ORIF group. The cost-minimization analysis demonstrated that the cost effectiveness of MIS was better than ORIF as the MIS was associated with a significantly lower total in-hospital direct medical cost ($8,900 vs. $5,786, P=0.032), compared with ORIF. The cost-minimization analysis demonstrated that for similar clinical baseline characteristics as well as outcomes, there were differences in direct hospitalization cost of two surgical techniques, and MIS had a lower cost on average than ORIF.
Collapse
Affiliation(s)
- Liang Ma
- School of Public Health, Shanghai Jiao Tong University, Shanghai 200025, P.R. China.,Department of Scientific Research Management, Shanghai General Hospital, Shanghai 200080, P.R. China
| | - Lei Ma
- Department of Scientific Research Management, Shanghai General Hospital, Shanghai 200080, P.R. China
| | - Yu Chen
- Department of Scientific Research Management, Shanghai General Hospital, Shanghai 200080, P.R. China
| | - Yifeng Jiang
- Department of Scientific Research Management, Shanghai General Hospital, Shanghai 200080, P.R. China
| | - Qiang Su
- School of Economics and Management, Tongji University, Shanghai 200092, P.R. China
| | - Qian Wang
- Department of Scientific Research Management, Shanghai General Hospital, Shanghai 200080, P.R. China
| | - Yanhong Zhu
- Department of Scientific Research Management, Shanghai General Hospital, Shanghai 200080, P.R. China
| |
Collapse
|
42
|
Yin Y, Zhang R, Li S, Su K, Hou Z, Zhang Y. Complications Following Internal Fixator in the Treatment of Pelvic Fracture. Orthopedics 2019; 42:e7-e13. [PMID: 30403824 DOI: 10.3928/01477447-20181102-06] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Accepted: 03/19/2018] [Indexed: 02/03/2023]
Abstract
The aim of this systematic review was to investigate the incidence of complications of the internal fixator in the treatment of anterior pelvic ring injury. The literature was comprehensively searched from 1980 to January 2017 to identify potential studies. Six studies involving 272 cases of anterior pelvic ring injury treated with the internal fixator were included in this meta-analysis. The rates of wound infection, heterotopic ossification, nerve paresthesia, pain, and fracture dislocation were 5.7%, 35.1%, 28.2%, 3.7%, and 3.0%, respectively. This new technique should be prudently used to treat pelvic fractures. [Orthopedics. 2019; 42(1):e7-e13.].
Collapse
|
43
|
Rickman M, Link BC, Solomon LB. Patient Weight-bearing after Pelvic Fracture Surgery-A Systematic Review of the Literature: What is the Modern Evidence Base? Strategies Trauma Limb Reconstr 2019; 14:45-52. [PMID: 32559267 PMCID: PMC7001596 DOI: 10.5005/jp-journals-10080-1414] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Background Little attention in the literature appears to have been paid to the issue of postoperative weight-bearing protocols for different injury patterns after pelvic fracture surgery. The primary aim of this study is to review the currently available literature to define the level of available evidence used to inform surgical decisions on weight-bearing after pelvic fracture surgery. Secondary aims are to assess the published methods of fracture classification, surgical management, and assessment or reporting of patient outcomes. Methods A systematic review of the English language literature from 1990 to 2016 was undertaken. Eligible papers were all papers reporting minimum 6-month outcomes following surgery for pelvic fractures in adults. Exclusion criteria included pathological fractures or those resulting from penetrating injury, solely osteoporotic fractures, or series with less than 6 months of follow-up data. Results There is very little published scientific data to inform the treating surgeon on postoperative weight-bearing protocols after pelvic fracture surgery, with no randomized trials and only 1 paper out of 122 stating this as a primary aim. More than half of the papers published did not state what postoperative protocol was employed. There is no standardization of outcome measures, with less than 20% of papers using the most common validated outcome scoring system; in contrast, there is good agreement on the use of either the Tile (75%) or Burgess and Young (20%) classification. Limitations Due to the lack of published studies looking at the topic of postoperative weight-bearing after pelvic fractures, no specific recommendations are possible. As large numbers of papers were included, they were not individually assessed for bias. Conclusion A review of postoperative weight-bearing regimes reveals a nonexistent scientific evidence base from which to make recommendations, although a consensus strategy has been identified. Future research needs to be directed at this topic, as has already been the case in numerous other fracture areas, since the advantages of early mobility are potentially significant. The reported methodology for assessing and reporting patient outcomes after pelvic fracture surgery reveals no consistent standards, and the majority of papers use no specific outcome scoring system. How to cite this article Rickman M, Link B-C, Solomon LB. Patient Weight-bearing after Pelvic Fracture Surgery-A Systematic Review of the Literature: What is the Modern Evidence Base? Strategies Trauma Limb Reconstr 2019;14(1):45-52.
Collapse
Affiliation(s)
- Mark Rickman
- Centre for Orthopaedic and Trauma Research, Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Bjorn-Christian Link
- Centre for Orthopaedic and Trauma Research, Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Lucian B Solomon
- Centre for Orthopaedic and Trauma Research, Discipline of Orthopaedics and Trauma, University of Adelaide, Adelaide, Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| |
Collapse
|
44
|
Huang G, Cai L, Jia X, Ji Y, Zhou Y, Mou X, Zhu Q, He F, Zhang Z. A novel hybrid fixation (percutaneous anterior pelvic bridge with K-wire) for the treatment of traumatic pelvic ring injury: A prospective study. Int J Surg 2018; 61:11-16. [PMID: 30500472 DOI: 10.1016/j.ijsu.2018.11.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2018] [Revised: 11/16/2018] [Accepted: 11/23/2018] [Indexed: 01/13/2023]
Abstract
BACKGROUND The aim of the study was to introduce a novel percutaneous technique for the treatment of pelvic ring injuries using a percutaneous anterior pelvic bridge (PAPB) with K-wire. METHODS From December 2010 to November 2016, a prospective study of 86 patients with anterior pelvic ring fracture (42 utilizing PAPB with K-wire and 44 utilizing PAPB). Patient data was retrieved from electronic charts. Radiological results were assessed based on the Matta criteria system to evaluate the quality of the reduction and time to union. Functional outcomes were evaluated using the Majeed scoring system. Postoperative complications were also recorded. RESULTS Age, sex, cause of injury, type of fracture, functional recovery, American Society of Anesthesiologists classification, union time, Majeed scoring and complications did not differ significantly between the two groups. The quality of the reduction and pain scoring differed between groups (all p-values < 0.05). Group A got better reduction and less pain scoring. CONCLUSIONS The novel percutaneous technique with hybrid fixation using PAPB with K-wire is a successful alternative for the treatment of pelvic ring injuries, which results in better quality of reduction and less pain scoring outcomes comparing to PAPB. May the PAPB + K-wire could provide more stability.
Collapse
Affiliation(s)
- Guangping Huang
- Department of Orthopaedics Surgery, The People's Hospital of Jianyang City (Affiliated Hospital of Chengdu Medical College), No.180 Hospital Road, Jianyang, Sichuan 641400, China.
| | - Leyi Cai
- Department of Orthopaedics Surgery, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, No.109, XueYuan West Road, Luheng District, Wenzhou, Zhejiang Province, 325000, China.
| | - Xufeng Jia
- Department of Orthopaedics Surgery, The People's Hospital of Jianyang City (Affiliated Hospital of Chengdu Medical College), No.180 Hospital Road, Jianyang, Sichuan 641400, China.
| | - Yong Ji
- Department of Orthopaedics Surgery, The People's Hospital of Jianyang City (Affiliated Hospital of Chengdu Medical College), No.180 Hospital Road, Jianyang, Sichuan 641400, China.
| | - Yu Zhou
- Department of Orthopaedics Surgery, The People's Hospital of Jianyang City (Affiliated Hospital of Chengdu Medical College), No.180 Hospital Road, Jianyang, Sichuan 641400, China.
| | - Xiaping Mou
- Department of Orthopaedics Surgery, The People's Hospital of Jianyang City (Affiliated Hospital of Chengdu Medical College), No.180 Hospital Road, Jianyang, Sichuan 641400, China.
| | - Qingmao Zhu
- Department of Orthopaedics Surgery, The People's Hospital of Jianyang City (Affiliated Hospital of Chengdu Medical College), No.180 Hospital Road, Jianyang, Sichuan 641400, China.
| | - Fayou He
- Department of Orthopaedics Surgery, The People's Hospital of Jianyang City (Affiliated Hospital of Chengdu Medical College), No.180 Hospital Road, Jianyang, Sichuan 641400, China.
| | - Zhaoyao Zhang
- Department of Orthopaedics Surgery, The People's Hospital of Jianyang City (Affiliated Hospital of Chengdu Medical College), No.180 Hospital Road, Jianyang, Sichuan 641400, China.
| |
Collapse
|
45
|
Abstract
Subcutaneous internal plate fixation for anterior pelvic ring injuries has become more common, but implants require removal, usually by 12 weeks. The purpose of this article is to report a novel, minimally invasive, endoscopic-assisted technique for the removal of subcutaneous anterior pelvic plates safely and atraumatically without violating the underlying fascia.
Collapse
|
46
|
Three-dimensional (3D) Printing Technology Assisted by Minimally Invasive Surgery for Pubic Rami Fractures. Curr Med Sci 2018; 38:827-833. [PMID: 30341516 DOI: 10.1007/s11596-018-1949-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2018] [Revised: 08/25/2018] [Indexed: 10/28/2022]
Abstract
The feasibility of three-dimensional (3D) printing technology combined with minimally invasive surgery in the treatment of pubic rami fractures was explored. From August 2015 to October 2017, a series of 30 patients who underwent surgical stabilization of their anterior pelvic ring (all utilizing the 3D printing technology) by one surgeon at a single hospital were studied. The minimally invasive incisions were made through anterior inferior cilia spine and pubic nodule. Data collected included the operative duration, the blood loss, the damage of the important tissue, the biographic union and the recovery of the function after the operation. Measurements on inlet and outlet pelvic cardiograph were made immediately post-operation and at all follow-up clinic visits. The scores of reduction and function were measured during follow-up. Results showed that the wounds of 30 patients were healed in the first stage, and there was no injury of important structures such as blood vessels and nerves. According to the Matta criteria, excellent effectiveness was obtained in 22 cases and good in 8 cases. According to the functional evaluation criteria of Majeed, excellent effectiveness was obtained in 21 cases and good in 9 cases. It was suggested that the 3D printing technology assisted by minimally invasive surgery can better evaluate the pelvic fracture before operation, which was helpful in plate modeling, and can shorten surgery duration and reduce intraoperative blood loss and complications. The positioning accuracy was improved, and better surgical result was finally achieved.
Collapse
|
47
|
Hung CC, Wu JL, Li YT, Cheng YW, Wu CC, Shen HC, Yeh TT. Minimally invasive treatment for anterior pelvic ring injuries with modified pedicle screw-rod fixation: a retrospective study. J Orthop Surg Res 2018; 13:238. [PMID: 30223882 PMCID: PMC6142692 DOI: 10.1186/s13018-018-0945-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Accepted: 09/06/2018] [Indexed: 01/13/2023] Open
Abstract
Background Pelvic ring injuries constitute only 2 to 8% of all fractures; however, they occur in 20% of polytrauma patients. High-energy pelvic fractures often result in mechanical instability of the pelvic ring. Successful treatment of unstable pelvic ring fractures remains a challenge for orthopedic surgeons. This study presents a novel internal fixation method for stabilizing unstable anterior pelvic ring fractures using a minimally invasive modified pedicle screw-rod fixation (MPSRF) technique. Methods This retrospective study included six patients with unstable pelvic ring injuries who underwent MPSRF, with or without posterior fixation. Intraoperative parameters such as blood loss, operative time, complications, and quality of reduction (Matta criteria) were recorded and evaluated by a blinded reviewer. Results In the present clinical series, the mean operative times and mean blood loss for unilateral versus bilateral anterior ring fixations were 176.0 min versus 295.6 min, and 153.3 mL versus 550.0 mL, respectively. No iatrogenic neuropraxia of the lateral femoral cutaneous nerve or femoral nerve palsy occurred. The reduction quality, graded by the Matta criteria, was excellent in five patients and good in one patient. Conclusions There were no infections, delayed unions, nonunions, or loss of reductions during the follow-up period. Only one patient suffered from a broken rod at 4 months postoperatively. The modified technique represents a novel, minimally invasive procedure for the treatment of anterior pelvic ring fractures and offers a reliable and effective alternative to currently available surgical techniques.
Collapse
Affiliation(s)
- Chun-Chi Hung
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325 Cheng-Kung Road, Section 2, Taipei, 114, Taiwan
| | - Jia-Lin Wu
- Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.,Department of Orthopedics, Taipei Medical University Hospital, Taipei, Taiwan
| | - Yuan-Ta Li
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325 Cheng-Kung Road, Section 2, Taipei, 114, Taiwan
| | - Yung-Wen Cheng
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325 Cheng-Kung Road, Section 2, Taipei, 114, Taiwan
| | - Chia-Chun Wu
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325 Cheng-Kung Road, Section 2, Taipei, 114, Taiwan
| | - Hsain-Chung Shen
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325 Cheng-Kung Road, Section 2, Taipei, 114, Taiwan
| | - Tsu-Te Yeh
- Department of Orthopedic Surgery, Tri-Service General Hospital and National Defense Medical Center, 325 Cheng-Kung Road, Section 2, Taipei, 114, Taiwan.
| |
Collapse
|
48
|
Abstract
The evaluation and management of pelvic ring injuries continues to evolve. Historic treatment was primarily nonsurgical, which yielded to open surgical treatment as the benefits of restoring pelvic anatomy and stability became clear. The development of percutaneous techniques for pelvic ring fixation enabled surgeons to reduce and stabilize certain injuries without the need for large open surgical dissections. Although percutaneous iliosacral screw fixation of sacral fractures and sacroiliac disruptions is the standard for most posterior pelvic ring injuries, the evaluation and treatment of anterior pelvic ring disruptions remains a controversial topic among surgeons who treat these injuries. Universally accepted indications for anterior pelvic ring stabilization do not exist, and there is little comparative data to support one surgical technique over another. In fact, some believe that for many injuries, the anterior ring rarely requires fixation after stable fixation of the posterior pelvic ring. The purpose of this work is to present a brief history on management of the anterior pelvic ring as a component of pelvic ring disruptions and briefly review the anatomy of the anterior pelvic ring. Finally, we will introduce the current techniques available for anterior pelvic reduction/stabilization and present information on evaluation of anterior ring stability as a means of guiding treatment.
Collapse
|
49
|
Abstract
INTRODUCTION The purpose of this article is to review the available literature on anterior subcutaneous internal pelvic fixation (ASIPF) to identify indications, clinical and radiographic outcomes, and compare these with alternative fixation methods. METHODS Using the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines, a systematic search on PubMed and Google Scholar was performed. Articles included were in the English language or English translations and published between 2007 and 2018. Studies included were appraised with narrative data synthesis. RESULTS Twenty-five articles with 496 patients were included. These included 17 case series, with 3 case reports reporting adverse events. CONCLUSIONS ASIPF and the appropriate posterior fixation resulted in healing of pelvic ring injuries in 99.5% of cases. Indications include unstable pelvic ring injuries with the appropriate posterior fixation. Radiographic parameters and outcome measures were infrequently reported. ASIPF is a valuable tool for reduction and fixation in unstable pelvic ring injuries. Complications include lateral femoral cutaneous nerve irritation (26.3%); heterotopic ossification (36%); infection (3%); and femoral nerve palsy (1%), which is likely related to placing the bar and screws too deep.
Collapse
|
50
|
Reichel LM, MacCormick LM, Dugarte AJ, Rizkala AR, Graves SC, Cole PA. Minimally invasive anterior pelvic internal fixation: An anatomic study comparing Pelvic Bridge to INFIX. Injury 2018; 49:309-314. [PMID: 29277392 DOI: 10.1016/j.injury.2017.12.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Revised: 12/03/2017] [Accepted: 12/10/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVES Anterior external fixation for pelvic ring fractures has shown to effectively improve stability and reduce mortality. However, these fixators can be associated with substantial morbidity such as pin tract infection, premature loss of fixation, and decreased quality of life in patients. Recently, two new methods of subcutaneous anterior pelvic internal fixation have been developed; the INFIX and the Pelvic Bridge. These methods have the purported advantages of lower wound complications, less surgical site pain, and improved quality of life. We sought to investigate the measured distances to critical anatomic structures, as well as the qualitative and topographic differences notable during implantation of both devices in the same cadaveric specimen. MATERIALS AND METHODS The Pelvic Bridge and INFIX were implanted in eleven fresh cadavers. Distances were then measured to: the superficial inguinal ring, round ligament, spermatic cord, lateral femoral cutaneous nerve (LFCN), femoral nerve, femoral artery, and femoral vein. Observations regarding implantation and topography were also recorded. RESULTS The INFIX had greater measured distances from all structures except for the LFCN, in which its proximity placed this structure at risk. Neither device appears to put other critical structures at risk in the supine position. Significant implantation and topographic differences exist between the devices. The INFIX application lacked "safety margins" concerning the LFCN in 10/11 (90.9%) specimens, while Pelvic Bridge placement lacked "safety margins" with regard to the right superficial ring (1/11, 9%) and the right spermatic cord (1/11, 9%). CONCLUSIONS Both the Pelvic Bridge and INFIX lie at safe distances from most critical pelvic structures in the supine position, though INFIX application places the LFCN at risk.
Collapse
Affiliation(s)
- Lee M Reichel
- Dell Medical School, University Of Texas, Surgery and Perioperative Care, United States
| | - Lauren M MacCormick
- University of Minnesota, Department of Orthopedic Surgery, Regions Hospital, United States
| | - Anthony J Dugarte
- University of Minnesota, Department of Orthopedic Surgery, Regions Hospital, United States
| | - Amir R Rizkala
- Stony Brook School of Medicine, Department of Physical Medicine and Rehabilitation, United States
| | - Sara C Graves
- Central Vermont Orthopaedics and Sports Medicine, University of Vermont health network, United States
| | - Peter A Cole
- University of Minnesota, Department of Orthopedic Surgery, Regions Hospital, United States.
| |
Collapse
|