1
|
Anderson B, Shahidi B. The Impact of Spine Pathology on Posterior Ligamentous Complex Structure and Function. Curr Rev Musculoskelet Med 2023; 16:616-626. [PMID: 37870725 PMCID: PMC10733250 DOI: 10.1007/s12178-023-09873-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/06/2023] [Indexed: 10/24/2023]
Abstract
PURPOSE OF REVIEW Spinal ligament is an important component of the spinal column in mitigating biomechanical stress. Particularly the posterior ligamentous complex, which is composed of the ligamentum flavum, interspinous, and supraspinous ligaments. However, research characterizing the biomechanics and role of ligament health in spinal pathology and clinical context are scarce. This article provides a comprehensive review of the implications of spinal pathology on the structure, function, and biomechanical properties of the posterior ligamentous complex. RECENT FINDINGS Current research characterizing biomechanical properties of the posterior ligamentous complex is primarily composed of cadaveric studies and finite element modeling, and more recently incorporating patient-specific anatomy into finite element models. The ultimate goal of current research is to understand the relative contributions of these ligamentous structures in healthy and pathological spine, and whether preserving ligaments may play an important role in spinal surgical techniques. At baseline, posterior ligamentous complex structures account for 30-40% of spinal stability, which is highly dependent on the intrinsic biomechanical properties of each ligament. Biomechanics vary widely with pathology and following rigid surgical fixation techniques and are generally maladaptive. Often secondary to morphological changes in the setting of spinal pathology, but morphological changes in ligament may also serve as a primary pathology. Biomechanical maladaptations of the spinal ligament adversely influence overall spinal column integrity and ultimately predispose to increased risk for surgical failure and poor clinical outcomes. Future research is needed, particularly in living subjects, to better characterize adaptations in ligaments that can provide targets for improved treatment of spinal pathology.
Collapse
Affiliation(s)
- Bradley Anderson
- Department of Orthopaedic Surgery, The University of California San Diego, 9500 Gilman Dr., MC0863, La Jolla, San Diego, CA, 92093, USA
| | - Bahar Shahidi
- Department of Orthopaedic Surgery, The University of California San Diego, 9500 Gilman Dr., MC0863, La Jolla, San Diego, CA, 92093, USA.
| |
Collapse
|
2
|
Morrison O, Destrade M, Tripathi BB. An atlas of the heterogeneous viscoelastic brain with local power-law attenuation synthesised using Prony-series. Acta Biomater 2023; 169:66-87. [PMID: 37507033 DOI: 10.1016/j.actbio.2023.07.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 07/16/2023] [Accepted: 07/24/2023] [Indexed: 07/30/2023]
Abstract
This review addresses the acute need to acknowledge the mechanical heterogeneity of brain matter and to accurately calibrate its local viscoelastic material properties accordingly. Specifically, it is important to compile the existing and disparate literature on attenuation power-laws and dispersion to make progress in wave physics of brain matter, a field of research that has the potential to explain the mechanisms at play in diffuse axonal injury and mild traumatic brain injury in general. Currently, viscous effects in the brain are modelled using Prony-series, i.e., a sum of decaying exponentials at different relaxation times. Here we collect and synthesise the Prony-series coefficients appearing in the literature for twelve regions: brainstem, basal ganglia, cerebellum, corona radiata, corpus callosum, cortex, dentate gyrus, hippocampus, thalamus, grey matter, white matter, homogeneous brain, and for eight different mammals: pig, rat, human, mouse, cow, sheep, monkey and dog. Using this data, we compute the fractional-exponent attenuation power-laws for different tissues of the brain, the corresponding dispersion laws resulting from causality, and the averaged Prony-series coefficients. STATEMENT OF SIGNIFICANCE: Traumatic brain injuries are considered a silent epidemic and finite element methods (FEMs) are used in modelling brain deformation, requiring access to viscoelastic properties of brain. To the best of our knowledge, this work presents 1) the first multi-frequency viscoelastic atlas of the heterogeneous brain, 2) the first review focusing on viscoelastic modelling in both FEMs and experimental works, 3) the first attempt to conglomerate the disparate existing literature on the viscoelastic modelling of the brain and 4) the largest collection of viscoelastic parameters for the brain (212 different Prony-series spanning 12 different tissues and 8 different animal surrogates). Furthermore, this work presents the first brain atlas of attenuation power-laws essential for modelling shear waves in brain.
Collapse
Affiliation(s)
- Oisín Morrison
- School of Mathematical and Statistical Sciences, University of Galway, University Road, Galway, Ireland
| | - Michel Destrade
- School of Mathematical and Statistical Sciences, University of Galway, University Road, Galway, Ireland
| | - Bharat B Tripathi
- School of Mathematical and Statistical Sciences, University of Galway, University Road, Galway, Ireland.
| |
Collapse
|
3
|
Najafidoust M, Hashemi A, Oskui IZ. Effect of temperature on dynamic compressive behavior of periodontal ligament. Med Eng Phys 2023; 116:103986. [PMID: 37230701 DOI: 10.1016/j.medengphy.2023.103986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 04/04/2023] [Accepted: 04/30/2023] [Indexed: 05/27/2023]
Abstract
Periodontal ligament (PDL) attaches tooth root to the surrounding bone. Its existence between tooth and jaw bone is of utmost importance due to its significant role in absorbing and distributing physiological and para-physiological loading. According to the previous studies, various mechanical tests have been performed to characterize the mechanical properties of the PDL; however, all of them have been done at room temperature. To the best of our knowledge, this is the first study in which the testing was performed at body temperature. The present research was planned to measure the dependency of PDL's viscoelastic behavior on temperature and frequency. Three different temperatures, including body and room temperature, were opted to perform the dynamic compressive tests of the bovine PDL. In addition, a Generalized Maxwell model (GMM) was presented based on empirical outcomes. At 37 °C, amounts of loss factor were found to be greater than those in 25 °C, which demonstrates that the viscous phase of the PDL in higher temperatures plays a critical role. Likewise, by raising the temperature from 25 °C to 37 °C, the model parameters show an enlargement in the viscous part and lessening in the elastic part. It was concluded that the PDL's viscosity in body temperature is much higher than that in room temperature. This model would be functional for a more accurate computational analysis of the PDL at the body temperature (37 °C) in various loading conditions such as orthodontic simulations, mastication, and impact.
Collapse
Affiliation(s)
- Mohammad Najafidoust
- Biomedical Engineering Group, Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran; Neuroscience Research Australia and Prince of Wales Clinical School, University of New South Wales, Randwick, NSW, Australia
| | - Ata Hashemi
- Biomedical Engineering Group, Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran.
| | - Iman Z Oskui
- Biomedical Engineering Group, Faculty of Biomedical Engineering, Sahand University of Technology, Tabriz, Iran.
| |
Collapse
|
4
|
Blomeyer N, Tandale SB, Nicolini LF, Kobbe P, Pufe T, Markert B, Stoffel M. Prediction of Temperature and Loading History Dependent Lumbar Spine Biomechanics Under Cyclic Loading Using Recurrent Neural Networks. Ann Biomed Eng 2023; 51:1244-1255. [PMID: 36709233 PMCID: PMC10172265 DOI: 10.1007/s10439-022-03128-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 12/25/2022] [Indexed: 01/30/2023]
Abstract
Extended-duration cyclic loading of the spine is known to be correlated to lower back pain (LBP). Therefore, it is important to understand how the loading history affects the entire structural behavior of the spine, including the viscoelastic effects. Six human spinal segments (L4L5) were loaded with pure moments up to 7.5 Nm cyclically for half an hour, kept unloaded for 15 min, and loaded with three cycles. This procedure was performed in flexion-extension (FE), axial rotation (AR), and lateral bending (LB) and repeated six times per direction for a total of 18 h of testing per segment. A Long Short-Term Memory (LSTM) Recurrent Neural Network (RNN) was trained to predict the change in the biomechanical response under cyclic loading. A strong positive correlation between the total testing time and the ratio of the third cycle to the last cycle of the loading sequence was found (BT: [Formula: see text] = 0.3469, p = 0.0003, RT: [Formula: see text] =0.1988, p = 0.0377). The moment-range of motion (RoM) curves could be very well predicted with an RNN ([Formula: see text]=0.988), including the correlation between testing time and testing temperature as inputs. This study shows successfully the feasibility of using RNNs to predict changing moment-RoM curves under cyclic moment loading.
Collapse
Affiliation(s)
- Nadja Blomeyer
- Institute of General Mechanics, RWTH Aachen University, Eilfschornsteinstr. 18, 52062, Aachen, Germany.
| | | | - Luis Fernando Nicolini
- Institute of General Mechanics, RWTH Aachen University, Eilfschornsteinstr. 18, 52062, Aachen, Germany.,Department of Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Philipp Kobbe
- Department of Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Thomas Pufe
- Department of Anatomy and Cell Biology, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Bernd Markert
- Institute of General Mechanics, RWTH Aachen University, Eilfschornsteinstr. 18, 52062, Aachen, Germany
| | - Marcus Stoffel
- Institute of General Mechanics, RWTH Aachen University, Eilfschornsteinstr. 18, 52062, Aachen, Germany
| |
Collapse
|
5
|
Bianchi L, Cavarzan F, Ciampitti L, Cremonesi M, Grilli F, Saccomandi P. Thermophysical and mechanical properties of biological tissues as a function of temperature: a systematic literature review. Int J Hyperthermia 2022; 39:297-340. [DOI: 10.1080/02656736.2022.2028908] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Affiliation(s)
- Leonardo Bianchi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Fabiana Cavarzan
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Lucia Ciampitti
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Matteo Cremonesi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Francesca Grilli
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
6
|
Lee NN, Salzer E, Bach FC, Bonilla AF, Cook JL, Gazit Z, Grad S, Ito K, Smith LJ, Vernengo A, Wilke H, Engiles JB, Tryfonidou MA. A comprehensive tool box for large animal studies of intervertebral disc degeneration. JOR Spine 2021; 4:e1162. [PMID: 34337336 PMCID: PMC8313180 DOI: 10.1002/jsp2.1162] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 05/25/2021] [Accepted: 05/26/2021] [Indexed: 12/12/2022] Open
Abstract
Preclinical studies involving large animal models aim to recapitulate the clinical situation as much as possible and bridge the gap from benchtop to bedside. To date, studies investigating intervertebral disc (IVD) degeneration and regeneration in large animal models have utilized a wide spectrum of methodologies for outcome evaluation. This paper aims to consolidate available knowledge, expertise, and experience in large animal preclinical models of IVD degeneration to create a comprehensive tool box of anatomical and functional outcomes. Herein, we present a Large Animal IVD Scoring Algorithm based on three scales: macroscopic (gross morphology, imaging, and biomechanics), microscopic (histological, biochemical, and biomolecular analyses), and clinical (neurologic state, mobility, and pain). The proposed algorithm encompasses a stepwise evaluation on all three scales, including spinal pain assessment, and relevant structural and functional components of IVD health and disease. This comprehensive tool box was designed for four commonly used preclinical large animal models (dog, pig, goat, and sheep) in order to facilitate standardization and applicability. Furthermore, it is intended to facilitate comparison across studies while discerning relevant differences between species within the context of outcomes with the goal to enhance veterinary clinical relevance as well. Current major challenges in pre-clinical large animal models for IVD regeneration are highlighted and insights into future directions that may improve the understanding of the underlying pathologies are discussed. As such, the IVD research community can deepen its exploration of the molecular, cellular, structural, and biomechanical changes that occur with IVD degeneration and regeneration, paving the path for clinically relevant therapeutic strategies.
Collapse
Affiliation(s)
- Naomi N. Lee
- Thompson Laboratory for Regenerative OrthopaedicsUniversity of MissouriColumbiaMissouriUSA
| | - Elias Salzer
- Orthopaedic Biomechanics, Department of Biomedical EngineeringEindhoven University of TechnologyEindhovenThe Netherlands
| | - Frances C. Bach
- Department of Clinical Sciences, Faculty of Veterinary MedicineUtrecht UniversityUtrechtThe Netherlands
| | - Andres F. Bonilla
- Preclinical Surgical Research Laboratory, Department of Clinical SciencesColorado State UniversityColoradoUSA
| | - James L. Cook
- Thompson Laboratory for Regenerative OrthopaedicsUniversity of MissouriColumbiaMissouriUSA
| | - Zulma Gazit
- Department of SurgeryCedars‐Sinai Medical CenterLos AngelesCaliforniaUSA
| | | | - Keita Ito
- Orthopaedic Biomechanics, Department of Biomedical EngineeringEindhoven University of TechnologyEindhovenThe Netherlands
| | - Lachlan J. Smith
- Departments of Neurosurgery and Orthopaedic SurgeryUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | - Andrea Vernengo
- AO Research Institute DavosDavosSwitzerland
- Department of Chemical EngineeringRowan UniversityGlassboroNew JerseyUSA
| | - Hans‐Joachim Wilke
- Institute of Orthopaedic Research and BiomechanicsUniversity Hospital UlmUlmGermany
| | - Julie B. Engiles
- Department of Pathobiology, New Bolton Center, School of Veterinary MedicineUniversity of PennsylvaniaKennett SquarePennsylvaniaUSA
| | - Marianna A. Tryfonidou
- Department of Clinical Sciences, Faculty of Veterinary MedicineUtrecht UniversityUtrechtThe Netherlands
| |
Collapse
|
7
|
Zwirner J, Scholze M, Ondruschka B, Hammer N. What is Considered a Variation of Biomechanical Parameters in Tensile Tests of Collagen-Rich Human Soft Tissues? - Critical Considerations Using the Human Cranial Dura Mater as a Representative Morpho-Mechanic Model. MEDICINA (KAUNAS, LITHUANIA) 2020; 56:E520. [PMID: 33027931 PMCID: PMC7600870 DOI: 10.3390/medicina56100520] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 09/27/2020] [Accepted: 09/28/2020] [Indexed: 12/23/2022]
Abstract
Background and Objectives: Profound knowledge on the load-dependent behavior of human soft tissues is required for the development of suitable replacements as well as for realistic computer simulations. Regarding the former, e.g., the anisotropy of a particular biological tissue has to be represented with site- and direction-dependent particular mechanical values. Contrary to this concept of consistent mechanical properties of a defined soft tissue, mechanical parameters of soft tissues scatter considerably when being determined in tensile tests. In spite of numerous measures taken to standardize the mechanical testing of soft tissues, several setup- and tissue-related factors remain to influence the mechanical parameters of human soft tissues to a yet unknown extent. It is to date unclear if measurement extremes should be considered a variation or whether these data have to be deemed incorrect measurement outliers. This given study aimed to determine mechanical parameters of the human cranial dura mater as a model for human soft tissues using a highly standardized protocol and based on this, critically evaluate the definition for the term mechanical "variation" of human soft tissue. Materials and Methods: A total of 124 human dura mater samples with an age range of 3 weeks to 94 years were uniformly retrieved, osmotically adapted and mechanically tested using customized 3D-printed equipment in a quasi-static tensile testing setup. Scanning electron microscopy of 14 samples was conducted to relate the mechanical parameters to morphological features of the dura mater. Results: The here obtained mechanical parameters were scattered (elastic modulus = 46.06 MPa, interquartile range = 33.78 MPa; ultimate tensile strength = 5.56 MPa, interquartile range = 4.09 MPa; strain at maximum force = 16.58%, interquartile range = 4.81%). Scanning electron microscopy revealed a multi-layered nature of the dura mater with varying fiber directions between its outer and inner surface. Conclusions: It is concluded that mechanical parameters of soft tissues such as human dura mater are highly variable even if a highly standardized testing setup is involved. The tissue structure and composition appeared to be the main contributor to the scatter of the mechanical parameters. In consequence, mechanical variation of soft tissues can be defined as the extremes of a biomechanical parameter due to an uncontrollable change in tissue structure and/or the respective testing setup.
Collapse
Affiliation(s)
- Johann Zwirner
- Department of Anatomy, University of Otago, Dunedin 9016, New Zealand
| | - Mario Scholze
- Institute of Materials Science and Engineering, Chemnitz University of Technology, 09125 Chemnitz, Germany;
- Department of Macroscopic and Clinical Anatomy, Medical University of Graz, 8010 Graz, Austria
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, 22529 Hamburg, Germany;
| | - Niels Hammer
- Department of Macroscopic and Clinical Anatomy, Medical University of Graz, 8010 Graz, Austria
- Department of Orthopaedic and Trauma Surgery, University of Leipzig, 04103 Leipzig, Germany
- Fraunhofer IWU, 01187 Dresden, Germany
| |
Collapse
|
8
|
Kranjec M, Trajkovski A, Krašna S, Hribernik M, Kunc R. Material properties of human patellar-ligament grafts from the elderly population. J Mech Behav Biomed Mater 2020; 110:103994. [PMID: 32771880 DOI: 10.1016/j.jmbbm.2020.103994] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 06/30/2020] [Accepted: 07/15/2020] [Indexed: 10/23/2022]
Abstract
The aim of the presented study was to estimate the material properties of human patellar ligaments from the elderly population by means of tensile tests. The experimental part was conducted on a custom tensile-testing device, with a built-in enclosure to simulate in-vivo conditions, using 25 (15 female, 10 male) bone-ligament-bone samples from elderly (age 83 (8)) human donors. During the tensile tests, the resultant force and displacement of the sample attachments were recorded. With this data and the values of the initial length and the initial cross-sectional area of the samples, the engineering stress and strain, the Young's modulus and the toughness at rupture were calculated for each sample. The results were then averaged and presented for all the samples together and for the female and male populations separately. The measured Young's modulus and the failure stress values were found to be significantly higher for the female samples compared to the male (p < 0.05). All the other measured properties did not show a significant difference. The toe region's material properties for the patellar ligament were also presented as valuable information for the anterior cruciate ligament reconstruction. The tensile-test results were compared to other research carried on human patellar ligaments using samples from younger donors. The comparison showed that the samples from the elderly population exhibit lower values of strain at the end of the toe region and have a lower failure strain for the patellar ligament. The Young's modulus and the failure stress of the samples in this study were in the range of other research conducted on patellar ligaments.
Collapse
Affiliation(s)
- Matej Kranjec
- University of Ljubljana, Faculty of Mechanical Engineering, Ljubljana, Slovenia.
| | - Ana Trajkovski
- University of Ljubljana, Faculty of Mechanical Engineering, Ljubljana, Slovenia.
| | - Simon Krašna
- University of Ljubljana, Faculty of Mechanical Engineering, Ljubljana, Slovenia.
| | - Marija Hribernik
- University of Ljubljana, Faculty of Medicine, Ljubljana, Slovenia.
| | - Robert Kunc
- University of Ljubljana, Faculty of Mechanical Engineering, Ljubljana, Slovenia.
| |
Collapse
|
9
|
Beckmann A, Herren C, Mundt M, Siewe J, Kobbe P, Sobottke R, Pape HC, Stoffel M, Markert B. A new in vitro spine test rig to track multiple vertebral motions under physiological conditions. ACTA ACUST UNITED AC 2018; 63:341-347. [DOI: 10.1515/bmt-2016-0173] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Accepted: 02/15/2017] [Indexed: 11/15/2022]
Abstract
Abstract
In vitro pure moment spine tests are commonly used to analyse surgical implants in cadaveric models. Most of the tests are performed at room temperature. However, some new dynamic instrumentation devices and soft tissues show temperature-dependent material properties. Therefore, the aim of this study is to develop a new test rig, which allows applying pure moments on lumbar spine specimens in a vapour-filled chamber at body temperature. As no direct sight is given in the vapour-filled closed chamber, a magnetic tracking (MT) system with implantable receivers was used. Four human cadaveric lumbar spines (L2–L5) were tested in a vapour atmosphere at body temperature with a native and rigid instrumented group. In conclusion, the experimental set-up allows vertebral motion tracking of multiple functional spinal units (FSUs) in a moisture environment at body temperature.
Collapse
|
10
|
Effects of a Thermal Agent and Physical Activity on Muscle Tendon Stiffness, as Well as the Effects Combined With Static Stretching. J Sport Rehabil 2018; 27:66-72. [PMID: 28051342 DOI: 10.1123/jsr.2015-0165] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
CONTEXT A recent review or article reported that thermal agents (TA) or physical activity (PA) can increase range of motion (ROM) and that the combination of TA with stretching is superior to performing stretching only. However, since ROM is affected by the psychological factors, it is questionable whether these studies measured the effect of these interventions on muscle flexibility. By measuring muscle stiffness, the authors attempted to evaluate the effect these interventions on muscle flexibility. OBJECTIVE To compare the individual effects of TA and PA on muscle flexibility, as well as their effectiveness when combined with static stretching (SS). DESIGN Crossover trial. SETTING University research laboratory. PARTICIPANTS 15 healthy men without a history of orthopedic disease in their lower limbs. INTERVENTIONS 15 minutes of 3 different conditions: hot pack as TA, pedaling exercise as PA, and the control group with no TA or PA intervention, followed by 3 min of SS for the hamstrings. MAIN OUTCOME MEASURES Joint angle and passive torque of the knee during passive elongation were obtained prior to interventions, after 3 kinds of intervention, and after SS. From these data, muscle-tendon-unit (MTU) stiffness of the hamstrings was calculated. RESULTS Although knee-joint ROM increased with both TA and PA (P < .05), there were no significant differences in MTU stiffness between pre- and postintervention measurements for either of the interventions (TA, P = .477; PA, P = .377; control, P = .388). However, there were similar significant decreases in MTU stiffness between postintervention and post-SS for all conditions (P < .01). CONCLUSIONS TA and PA did not decrease MTU stiffness, and combining these interventions with SS did not provide additional decreases in MTU stiffness compared with performing SS alone.
Collapse
|
11
|
Smeets K, Slane J, Scheys L, Claes S, Bellemans J. Mechanical Analysis of Extra-Articular Knee Ligaments. Part One: Native knee ligaments. Knee 2017; 24:949-956. [PMID: 28784565 DOI: 10.1016/j.knee.2017.07.013] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 06/15/2017] [Accepted: 07/20/2017] [Indexed: 02/02/2023]
Abstract
BACKGROUND The aim of this study was to provide a characterization of the tensile properties of the medial collateral ligament (MCL), lateral collateral ligament (LCL), anterolateral ligament (ALL) and medial patellofemoral ligament (MPFL). Our hypothesis was that extra-articular knee ligaments are heterogeneous in nature and possess distinct material properties. METHODS MCL (n=12), LCL (n=11), MPFL (n=12) and ALL (n=19) samples from fresh frozen human cadaveric knees were subjected to uniaxial tensile testing to failure and analyzed for their material properties. The elastic modulus (slope of the linear portion of the stress/strain curve), ultimate stress (stress at failure), ultimate strain (strain at failure) and strain energy density (area under the stress/strain curve) were calculated. RESULTS The MCL had the highest elastic modulus (441.8±117.2MPa) and was significantly greater than the MPFL (294.6±190.4MPa) and LCL (289.0±159.7MPa) (P<0.05) as well as the ALL (173.7±91.8MPa) (P<0.001). The ultimate stress was significantly higher (P<0.05) for the LCL (83.6±38.1MPa) and MCL (72.4±20.7MPa), relative to the MPFL (49.1±31.0MPa) and ALL (46.4±20.1MPa). The ultimate strain of the LCL (41.0±9.9%) and ALL (37.8±7.9%) were significantly higher (P<0.05) compared to the MCL (22.9±2.5%) and MPFL (22.2±5.6%). The strain energy density of the LCL (15.2±6.4MPa) was significantly greater (P<0.05) than all other ligaments (ALL 7.8±3.1MPa, MCL 7.5±2.9MPa and MPFL 5.0±2.9MPa). CONCLUSIONS Extra-articular knee ligaments are a heterogeneous group with respect to material characteristics. Each ligament has tensile properties that are significantly different from others and treatment strategies should take these findings into account.
Collapse
Affiliation(s)
- Kristof Smeets
- Doctoral School for Medicine and Life Sciences, Hasselt University, Diepenbeek, Belgium; Department of Orthopedic Surgery, Ziekenhuis Oost-Limburg, Genk, Belgium.
| | - Joshua Slane
- Institute for Orthopaedic Research and Training, Division of Orthopaedics, University Hospitals Leuven/Department of Development and Regenartion, Faculty of Medicine, KULeuven, Leuven, Belgium
| | - Lennart Scheys
- Institute for Orthopaedic Research and Training, Division of Orthopaedics, University Hospitals Leuven/Department of Development and Regenartion, Faculty of Medicine, KULeuven, Leuven, Belgium
| | - Steven Claes
- Department of Orthopedic Surgery, AZ Herentals Hospital, Herentals, Belgium; Department of Orthopedic Surgery, University Hospitals Leuven, Pellenberg, Belgium
| | - Johan Bellemans
- Department of Orthopedic Surgery, Ziekenhuis Oost-Limburg, Genk, Belgium; Faculty of Medicine and Life Sciences, Hasselt University, Diepenbeek, Belgium
| |
Collapse
|
12
|
Fiber-based modeling of in situ ankle ligaments with consideration of progressive failure. J Biomech 2017; 61:102-110. [DOI: 10.1016/j.jbiomech.2017.07.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2016] [Revised: 04/13/2017] [Accepted: 07/10/2017] [Indexed: 11/23/2022]
|
13
|
Smeets K, Slane J, Scheys L, Forsyth R, Claes S, Bellemans J. The Anterolateral Ligament Has Similar Biomechanical and Histologic Properties to the Inferior Glenohumeral Ligament. Arthroscopy 2017; 33:1028-1035.e1. [PMID: 28359668 DOI: 10.1016/j.arthro.2017.01.038] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 01/26/2017] [Accepted: 01/30/2017] [Indexed: 02/02/2023]
Abstract
PURPOSE To characterize the tensile and histologic properties of the anterolateral ligament (ALL), inferior glenohumeral ligament (IGHL), and knee capsule. METHODS Standardized samples of the ALL (n = 19), anterolateral knee capsule (n = 15), and IGHL (n = 13) were isolated from fresh-frozen human cadavers for uniaxial tensile testing to failure. An additional 6 samples of the ALL, capsule, and IGHL were procured for histologic analysis and determination of elastin content. RESULTS All investigated mechanical properties were significantly greater for both the ALL and IGHL when compared with capsular tissue. In contrast, no significant differences between the ALL and IGHL were found for any property. The elastic modulus of ALL and IGHL samples was 174 ± 92 MPa and 139 ± 60 MPa, respectively, compared with 62 ± 30 MPa for the capsule (P = .001). Ultimate stress was significantly lower (P < .001) for the capsule, at 13.4 ± 7.7 MPa, relative to the ALL and IGHL, at 46.4 ± 20.1 MPa and 38.7 ± 16.3 MPa, respectively. The ultimate strain at failure was 37.8% ± 7.9% for the ALL and 39.5% ± 9.4% for the IGHL; this was significantly greater (P = .041 and P = .02, respectively) for both relative to the capsule, at 32.6% ± 8.4%. The strain energy density was 7.8 ± 3.1 MPa for the ALL, 2.1 ± 1.3 MPa for the capsule, and 7.1 ± 3.1 MPa for the IGHL (P < .001). The ALL and IGHL consisted of collagen bundles aligned in a parallel manner, containing elastin bundles, which was in contrast to the random collagen architecture noted in capsule samples. CONCLUSIONS The ALL has similar tensile and histologic properties to the IGHL. The tensile properties of the ALL are significantly greater than those observed in the knee capsule. CLINICAL RELEVANCE: The ALL is not just a thickening of capsular tissue and should be considered a distinct ligamentous structure comparable to the IGHL in the shoulder. The tensile behavior of the ALL is similar to the IGHL, and treatment strategies should take this into account.
Collapse
Affiliation(s)
- Kristof Smeets
- Doctoral School for Medicine and Life Sciences, Hasselt University, Hasselt, Belgium; Department of Orthopedic Surgery, Ziekenhuis Oost-Limburg, Genk, Belgium.
| | - Josh Slane
- Institute for Orthopaedic Research and Training, University Hospitals Leuven, Campus Pellenberg, Pellenberg, Belgium
| | - Lennart Scheys
- Institute for Orthopaedic Research and Training, University Hospitals Leuven, Campus Pellenberg, Pellenberg, Belgium
| | - Ramses Forsyth
- Department of Pathology, University Hospital Brussels, Brussels, Belgium
| | - Steven Claes
- Department of Orthopedic Surgery, AZ Herentals Hospital, Herentals, Belgium
| | - Johan Bellemans
- Department of Orthopedic Surgery, Ziekenhuis Oost-Limburg, Genk, Belgium
| |
Collapse
|
14
|
Haslerud S, Lopes-Martins RAB, Frigo L, Bjordal JM, Marcos RL, Naterstad IF, Magnussen LH, Joensen J. Low-Level Laser Therapy and Cryotherapy as Mono- and Adjunctive Therapies for Achilles Tendinopathy in Rats. Photomed Laser Surg 2017; 35:32-42. [DOI: 10.1089/pho.2016.4150] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Affiliation(s)
- Sturla Haslerud
- NorPhyPain Research Group, Faculty of Health and Social Sciences, Centre for Evidence Based Practice, Bergen University College, Bergen, Norway
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | | | - Lúcio Frigo
- Centro de Ciências da Saúde, Universidade Cruzeiro do Sul, São Paulo, Brazil
| | - Jan Magnus Bjordal
- NorPhyPain Research Group, Faculty of Health and Social Sciences, Centre for Evidence Based Practice, Bergen University College, Bergen, Norway
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | - Rodrigo Labat Marcos
- Programa de Pós-Graduação em Biofotônica Aplicada as Ciências da Saúde, Universidade Nove de Julho, São Paulo, Brazil
| | - Ingvill Fjell Naterstad
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
| | - Liv Heide Magnussen
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
- Department of Occupational Therapy, Physiotherapy and Radiography, Faculty of Health and Social Sciences, Bergen University College, Bergen, Norway
| | - Jon Joensen
- Physiotherapy Research Group, Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway
- Department of Occupational Therapy, Physiotherapy and Radiography, Faculty of Health and Social Sciences, Bergen University College, Bergen, Norway
| |
Collapse
|
15
|
Hindman BJ, Fontes RB, From RP, Traynelis VC, Todd MM, Puttlitz CM, Santoni BG. Intubation biomechanics: laryngoscope force and cervical spine motion during intubation in cadavers—effect of severe distractive-flexion injury on C3–4 motion. J Neurosurg Spine 2016; 25:545-555. [DOI: 10.3171/2016.3.spine1640] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE
With application of the forces of intubation, injured (unstable) cervical segments may move more than they normally do, which can result in spinal cord injury. The authors tested whether, during endotracheal intubation, intervertebral motion of an injured C3–4 cervical segment 1) is greater than that in the intact (stable) state and 2) differs when a high- or low-force laryngoscope is used.
METHODS
Fourteen cadavers underwent 3 intubations using force-sensing laryngoscopes while simultaneous cervical spine motion was recorded with lateral fluoroscopy. The first intubation was performed with an intact cervical spine and a conventional high-force line-of-sight Macintosh laryngoscope. After creation of a severe C3–4 distractive-flexion injury, 2 additional intubations were performed, one with the Macintosh laryngoscope and the other with a low-force indirect video laryngoscope (Airtraq), used in random order.
RESULTS
During Macintosh intubations, between the intact and the injured conditions, C3–4 extension (0.3° ± 3.0° vs 0.4° ± 2.7°, respectively; p = 0.9515) and anterior-posterior subluxation (−0.1 ± 0.4 mm vs −0.3 ± 0.6 mm, respectively; p = 0.2754) did not differ. During Macintosh and Airtraq intubations with an injured C3–4 segment, despite a large difference in applied force between the 2 laryngoscopes, segmental extension (0.4° ± 2.7° vs 0.3° ± 3.3°, respectively; p = 0.8077) and anterior-posterior subluxation (0.3 ± 0.6 mm vs 0.0 ± 0.7 mm, respectively; p = 0.3203) did not differ.
CONCLUSIONS
The authors' hypotheses regarding the relationship between laryngoscope force and the motion of an injured cervical segment were not confirmed. Motion-force relationships (biomechanics) of injured cervical intervertebral segments during endotracheal intubation in cadavers are not predicted by the in vitro biomechanical behavior of isolated cervical segments. With the limitations inherent to cadaveric studies, the results of this study suggest that not all forms of cervical spine injury are at risk for pathological motion and cervical cord injury during conventional high-force line-of-sight intubation.
Collapse
Affiliation(s)
- Bradley J. Hindman
- 1Department of Anesthesia, University of Iowa, Roy J. and Lucille A. Carver College of Medicine, Iowa City, Iowa
| | - Ricardo B. Fontes
- 2Department of Neurosurgery, Rush University Medical Center, Chicago, Illinois
| | - Robert P. From
- 1Department of Anesthesia, University of Iowa, Roy J. and Lucille A. Carver College of Medicine, Iowa City, Iowa
| | | | - Michael M. Todd
- 1Department of Anesthesia, University of Iowa, Roy J. and Lucille A. Carver College of Medicine, Iowa City, Iowa
| | - Christian M. Puttlitz
- 3Department of Mechanical Engineering, School of Biomedical Engineering, Orthopaedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, Colorado; and
| | | |
Collapse
|
16
|
Freiwald J, Baumgart C, Kühnemann M, Hoppe MW. Foam-Rolling in sport and therapy – Potential benefits and risks. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.orthtr.2016.07.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
17
|
Intubation Biomechanics: Laryngoscope Force and Cervical Spine Motion during Intubation in Cadavers-Cadavers versus Patients, the Effect of Repeated Intubations, and the Effect of Type II Odontoid Fracture on C1-C2 Motion. Anesthesiology 2016; 123:1042-58. [PMID: 26288267 DOI: 10.1097/aln.0000000000000830] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The aims of this study are to characterize (1) the cadaver intubation biomechanics, including the effect of repeated intubations, and (2) the relation between intubation force and the motion of an injured cervical segment. METHODS Fourteen cadavers were serially intubated using force-sensing Macintosh and Airtraq laryngoscopes in random order, with simultaneous cervical spine motion recorded with lateral fluoroscopy. Motion of the C1-C2 segment was measured in the intact and injured state (type II odontoid fracture). Injured C1-C2 motion was proportionately corrected for changes in intubation forces that occurred with repeated intubations. RESULTS Cadaver intubation biomechanics were comparable with those of patients in all parameters other than C2-C5 extension. In cadavers, intubation force (set 2/set 1 force ratio = 0.61; 95% CI, 0.46 to 0.81; P = 0.002) and Oc-C5 extension (set 2 - set 1 difference = -6.1 degrees; 95% CI, -11.4 to -0.9; P = 0.025) decreased with repeated intubations. In cadavers, C1-C2 extension did not differ (1) between intact and injured states; or (2) in the injured state, between laryngoscopes (with and without force correction). With force correction, in the injured state, C1-C2 subluxation was greater with the Airtraq (mean difference 2.8 mm; 95% CI, 0.7 to 4.9 mm; P = 0.004). CONCLUSIONS With limitations, cadavers may be clinically relevant models of intubation biomechanics and cervical spine motion. In the setting of a type II odontoid fracture, C1-C2 motion during intubation with either the Macintosh or the Airtraq does not appear to greatly exceed physiologic values or to have a high likelihood of hyperextension or direct cord compression.
Collapse
|
18
|
Holsgrove TP, Gill HS, Miles AW, Gheduzzi S. Dynamic, six-axis stiffness matrix characteristics of the intact intervertebral disc and a disc replacement. Proc Inst Mech Eng H 2015; 229:769-77. [PMID: 26503838 DOI: 10.1177/0954411915610601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Thorough pre-testing is critical in assessing the likely in vivo performance of spinal devices prior to clinical use. However, there is a lack of data available concerning the dynamic testing of lumbar (porcine model) total disc replacements in all six axes under preload conditions. The aim of this study was to provide new data comparing porcine lumbar spinal specimen stiffness between the intact state and after the implantation of an unconstrained total disc replacement, in 6 degrees of freedom. The dynamic, stiffness matrix testing of six porcine lumbar isolated disc specimens was completed using triangle waves at a test frequency of 0.1 Hz. An axial preload of 500 N was applied during all testing. Specimens were tested both in the intact condition and after the implantation of the total disc replacement. Sixteen key stiffness terms were identified for the comparison of the intact and total disc replacement specimens, comprising the 6 principal stiffness terms and 10 key off-axis stiffness terms. The total disc replacement specimens were significantly different to the intact specimens in 12 of these key terms including all six principal stiffness terms. The implantation of the total disc replacement resulted in a mean reduction in the principal stiffness terms of 100%, 91%, and 98% in lateral bending, flexion-extension, and axial rotation, respectively. The novel findings of this study have demonstrated that the unconstrained, low-friction total disc replacement does not replicate the stiffness of the intact specimens. It is likely that other low-friction total disc replacements would produce similar results due to stiffness being actively minimised as part of the design of low-friction devices, without the introduction of stiffening elements or mechanisms to more accurately replicate the mechanical properties of the natural intervertebral disc. This study has demonstrated, for the first time, a method for the quantitative comparative mechanical function testing of total disc replacements and provides baseline data for the development of future devices.
Collapse
Affiliation(s)
| | | | - Anthony W Miles
- Centre for Orthopaedic Biomechanics, University of Bath, Bath, UK
| | - Sabina Gheduzzi
- Centre for Orthopaedic Biomechanics, University of Bath, Bath, UK
| |
Collapse
|
19
|
Markovic G. Acute effects of instrument assisted soft tissue mobilization vs. foam rolling on knee and hip range of motion in soccer players. J Bodyw Mov Ther 2015; 19:690-6. [DOI: 10.1016/j.jbmt.2015.04.010] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2015] [Revised: 03/14/2015] [Accepted: 04/26/2015] [Indexed: 10/23/2022]
|
20
|
Holsgrove TP, Nayak NR, Welch WC, Winkelstein BA. Advanced Multi-Axis Spine Testing: Clinical Relevance and Research Recommendations. Int J Spine Surg 2015; 9:34. [PMID: 26273552 DOI: 10.14444/2034] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Back pain and spinal degeneration affect a large proportion of the general population. The economic burden of spinal degeneration is significant, and the treatment of spinal degeneration represents a large proportion of healthcare costs. However, spinal surgery does not always provide improved clinical outcomes compared to non-surgical alternatives, and modern interventions, such as total disc replacement, may not offer clinically relevant improvements over more established procedures. Although psychological and socioeconomic factors play an important role in the development and response to back pain, the variation in clinical success is also related to the complexity of the spine, and the multi-faceted manner by which spinal degeneration often occurs. The successful surgical treatment of degenerative spinal conditions requires collaboration between surgeons, engineers, and scientists in order to provide a multi-disciplinary approach to managing the complete condition. In this review, we provide relevant background from both the clinical and the basic research perspectives, which is synthesized into several examples and recommendations for consideration in increasing translational research between communities with the goal of providing improved knowledge and care. Current clinical imaging, and multi-axis testing machines, offer great promise for future research by combining invivo kinematics and loading with in-vitro testing in six degrees of freedom to offer more accurate predictions of the performance of new spinal instrumentation. Upon synthesis of the literature, it is recommended that in-vitro tests strive to recreate as many aspects of the in-vivo environment as possible, and that a physiological preload is a critical factor in assessing spinal biomechanics in the laboratory. A greater link between surgical procedures, and the outcomes in all three anatomical planes should be considered in both the in-vivo and in-vitro settings, to provide data relevant to quality of motion, and stability.
Collapse
Affiliation(s)
- Timothy P Holsgrove
- Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA
| | - Nikhil R Nayak
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, PA
| | - William C Welch
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, PA
| | - Beth A Winkelstein
- Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA
| |
Collapse
|
21
|
Urbanczyk CA, Palmeri ML, Bass CR. Material characterization of in vivo and in vitro porcine brain using shear wave elasticity. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:713-723. [PMID: 25683220 PMCID: PMC4421908 DOI: 10.1016/j.ultrasmedbio.2014.10.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2014] [Revised: 10/24/2014] [Accepted: 10/24/2014] [Indexed: 06/04/2023]
Abstract
Realistic computer simulation of closed head trauma requires accurate mechanical properties of brain tissue, ideally in vivo. A substantive deficiency of most existing experimental brain data is that properties were identified through in vitro mechanical testing. This study develops a novel application of shear wave elasticity imaging to assess porcine brain tissue shear modulus in vivo. Shear wave elasticity imaging is a quantitative ultrasound technique that has been used here to examine changes in brain tissue shear modulus as a function of several experimental and physiologic parameters. Animal studies were performed using two different ultrasound transducers to explore the differences in physical response between closed skull and open skull arrangements. In vivo intracranial pressure in four animals was varied over a relevant physiologic range (2-40 mmHg) and was correlated with shear wave speed and stiffness estimates in brain tissue. We found that stiffness does not vary with modulation of intracranial pressure. Additional in vitro porcine specimens (n = 14) were used to investigate variation in brain tissue stiffness with temperature, confinement, spatial location and transducer orientation. We observed a statistically significant decrease in stiffness with increased temperature (23%) and an increase in stiffness with decreasing external confinement (22-37%). This study determined the feasibility of using shear wave elasticity imaging to characterize porcine brain tissue both in vitro and in vivo. Our results underline the importance of temperature- and skull-derived boundary conditions to brain stiffness and suggest that physiologic ranges of intracranial pressure do not significantly affect in situ brain tissue properties. Shear wave elasticity imaging allowed for brain material properties to be experimentally characterized in a physiologic setting and provides a stronger basis for assessing brain injury in computational models.
Collapse
Affiliation(s)
- Caryn A Urbanczyk
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
| | - Mark L Palmeri
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Cameron R Bass
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| |
Collapse
|
22
|
Holsgrove TP, Gill HS, Miles AW, Gheduzzi S. The dynamic, six-axis stiffness matrix testing of porcine spinal specimens. Spine J 2015; 15:176-84. [PMID: 25224452 DOI: 10.1016/j.spinee.2014.09.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 07/03/2014] [Accepted: 09/03/2014] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Complex testing protocols are required to fully understand the biomechanics of the spine. There remains limited data concerning the mechanical properties of spinal specimens under dynamic loading conditions in six axes. PURPOSE To provide new data on the mechanical properties of functional spinal unit (FSU) and isolated disc (ISD) spinal specimens in 6 df. STUDY DESIGN Dynamic, six-axis stiffness matrix testing of porcine lumbar spinal specimens. METHODS The stiffness matrix testing of lumbar porcine FSU (n=6) and ISD (n=6) specimens was completed in a custom six-axis spine simulator using triangle wave cycles at a frequency of 0.1 Hz. Specimens were first tested without an axial preload, then with an axial preload of 500 N, with equilibration times of both 30 and 60 minutes. RESULTS The stiffness matrices were not symmetrical about the principal stiffness terms. The facets increased all the principal stiffness terms with the exception of axial compression-extension. Significant differences were detected in 15 stiffness terms because of the application of an axial preload in the ISD specimens, including an increase in all principal stiffness terms. There were limited differences in stiffness because of equilibration time of 30 and 60 minutes. CONCLUSIONS The assumption of stiffness matrix symmetry used in many previous studies is not valid. The biomechanical testing of spinal specimens should be completed in 6 df, at physiologic loading rates, and incorporate the application of an axial preload. The present study has provided new data on the mechanical properties of spinal specimens and demonstrates that the dynamic stiffness matrix method provides a means to more fully understand the natural spine and quantitatively assess spinal instrumentation.
Collapse
Affiliation(s)
- Timothy Patrick Holsgrove
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK.
| | - Harinderjit Singh Gill
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK
| | - Anthony W Miles
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK
| | - Sabina Gheduzzi
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK
| |
Collapse
|
23
|
Abstract
Environmental temperature can have a surprising impact on extremity growth in homeotherms, but the underlying mechanisms have remained elusive for over a century. Limbs of animals raised at warm ambient temperature are significantly and permanently longer than those of littermates housed at cooler temperature. These remarkably consistent lab results closely resemble the ecogeographical tenet described by Allen's "extremity size rule," that appendage length correlates with temperature and latitude. This phenotypic growth plasticity could have adaptive significance for thermal physiology. Shortened extremities help retain body heat in cold environments by decreasing surface area for potential heat loss. Homeotherms have evolved complex mechanisms to maintain tightly regulated internal temperatures in challenging environments, including "facultative extremity heterothermy" in which limb temperatures can parallel ambient. Environmental modulation of tissue temperature can have direct and immediate consequences on cell proliferation, metabolism, matrix production, and mineralization in cartilage. Temperature can also indirectly influence cartilage growth by modulating circulating levels and delivery routes of essential hormones and paracrine regulators. Using an integrated approach, this article synthesizes classic studies with new data that shed light on the basis and significance of this enigmatic growth phenomenon and its relevance for treating human bone elongation disorders. Discussion centers on the vasculature as a gateway to understanding the complex interconnection between direct (local) and indirect (systemic) mechanisms of temperature-enhanced bone lengthening. Recent advances in imaging modalities that enable the dynamic study of cartilage growth plates in vivo will be key to elucidating fundamental physiological mechanisms of long bone growth regulation.
Collapse
Affiliation(s)
- Maria A Serrat
- Department of Anatomy and Pathology, Joan C. Edwards School of Medicine, Marshall University, Huntington, West Virginia
| |
Collapse
|
24
|
Williams JM, Haq I, Lee RY. An experimental study investigating the effect of pain relief from oral analgesia on lumbar range of motion, velocity, acceleration and movement irregularity. BMC Musculoskelet Disord 2014; 15:304. [PMID: 25228332 PMCID: PMC4171543 DOI: 10.1186/1471-2474-15-304] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Accepted: 09/11/2014] [Indexed: 11/11/2022] Open
Abstract
Background Movement alterations are often reported in individuals with back pain. However the mechanisms behind these movement alterations are not well understood. A commonly cited mechanism is pain. The aim of this study was to investigate the effect of pain reduction, from oral analgesia, on lumbar kinematics in individuals with acute and chronic low back pain. Methods A prospective, cross-sectional, experimental repeated-measures design was used. Twenty acute and 20 chronic individuals with low back pain were recruited from General Practitioner and self-referrals to therapy departments for low back pain. Participants complained of movement evoked low back pain. Inertial sensors were attached to the sacrum and lumbar spine and used to measure kinematics. Kinematic variables measured were range of motion, angular velocity and angular acceleration as well as a determining movement irregularity (a measure of deviation from smooth motion). Kinematics were investigated before and after administration of oral analgesia to instigate pain reduction. Results Pain was significantly reduced following oral analgesia. There were no significant effects on the kinematic variables before and after pain reduction from oral analgesia. There was no interaction between the variables group (acute and chronic) and time (pre and post pain reduction). Conclusion The results demonstrate that pain reduction did not alter lumbar range of motion, angular velocity, angular acceleration or movement irregularity questioning the role of pain in lumbar kinematics. Electronic supplementary material The online version of this article (doi:10.1186/1471-2474-15-304) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Jonathan M Williams
- Bournemouth University, School of Health and Social Care, Royal London House, Christchurch Road, Bournemouth, Dorset BH1 3LT, UK.
| | | | | |
Collapse
|
25
|
Holsgrove TP, Gheduzzi S, Gill HS, Miles AW. The development of a dynamic, six-axis spine simulator. Spine J 2014; 14:1308-17. [PMID: 24321131 DOI: 10.1016/j.spinee.2013.11.045] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 11/07/2013] [Accepted: 11/26/2013] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Although a great deal of research has been completed to characterize the stiffness of spinal specimens, there remains a limited understanding of the spine in 6 df and there is a lack of data from dynamic testing in six axes. PURPOSE This study details the development and validation of a dynamic six-axis spine simulator. STUDY DESIGN Biomechanical study. METHODS A synthetic spinal specimen was used for the purpose of tuning the simulator, completing positional accuracy tests, and measuring frequency response under physiological conditions. The spine simulator was used to complete stiffness matrix tests of an L3-L4 lumbar porcine functional spinal unit. Five testing frequencies were used, ranging from quasistatic (0.00575 Hz) to dynamic (0.5 Hz). Tests were performed without an axial preload and with an axial preload of 500 N. RESULTS The validation tests demonstrated that the simulator is capable of producing accurate positioning under loading at frequencies up to 0.5 Hz using both sine and triangle waveforms. The porcine stiffness matrix tests demonstrated that the stiffness matrix is not symmetrical about the principal stiffness diagonal. It was also shown that while an increase in test frequency generally increased the principal stiffness terms, axial preload had a much greater effect. CONCLUSIONS The spine simulator is capable of characterizing the dynamic biomechanics of the spine in six axes and provides a means to better understand the complex behavior of the spine under physiological conditions.
Collapse
Affiliation(s)
- Timothy Patrick Holsgrove
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK.
| | - Sabina Gheduzzi
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK
| | - Harinderjit Singh Gill
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK
| | - Anthony W Miles
- Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK
| |
Collapse
|
26
|
Frimenko RE, Lievers WB, Riley PO, Park JS, Hogan MV, Crandall JR, Kent RW. Development of an injury risk function for first metatarsophalangeal joint sprains. Med Sci Sports Exerc 2014; 45:2144-50. [PMID: 23657164 DOI: 10.1249/mss.0b013e3182994a10] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
INTRODUCTION Sprains of the first metatarsophalangeal (1MTP) joint, also known as turf toe, are debilitating athletic injuries. Because 85% of 1MTP sprains result from excessive hallux dorsiflexion, interventions that limit motion to subinjurious levels would greatly benefit athletes. Hallux dorsiflexion range of motion (hdROM) cannot be overly constrained, however, lest athletic performance be compromised. Therefore, the tolerance of the 1MTP joint to excessive dorsiflexion injury must be quantified before appropriate hdROM limitations may be developed. The purpose of this study was to develop a quantitative injury risk function for 1MTP sprains on the basis of hallux dorsiflexion angle. METHODS Twenty cadaveric limbs were tested to both subinjurious and injurious levels of hallux dorsiflexion. Motion capture techniques were used to track six-degree-of-freedom motion of the first proximal phalanx, first metatarsal, and calcaneus. Specimens were examined by physicians posttest to diagnose injury occurrence and ensure clinical relevance of the injuries. RESULTS A two-parameter Weibull hazard function analysis reveals that a 50% risk of injury occurs at 78° of dorsiflexion from anatomical zero. CONCLUSION Methods presented here drove cadaveric 1MTP joints to various degrees of dorsiflexion, resulting in both noninjurious and injurious trials, which were formed into an injury risk function.
Collapse
Affiliation(s)
- Rebecca E Frimenko
- 1Center for Applied Biomechanics, University of Virginia, Charlottesville, VA; 2Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA; and 3Department of Orthopaedic Surgery, University of Virginia, Charlottesville, VA
| | | | | | | | | | | | | |
Collapse
|
27
|
Hofer P, Hasler M, Fauland G, Bechtold T, Nachbauer W. Microclimate in ski boots--temperature, relative humidity, and water absorption. APPLIED ERGONOMICS 2014; 45:515-520. [PMID: 23932378 DOI: 10.1016/j.apergo.2013.07.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2012] [Revised: 07/03/2013] [Accepted: 07/08/2013] [Indexed: 06/02/2023]
Abstract
Ski boot quality is determined by mechanical properties and comfort. Comfort is strongly affected by cold feet. The purpose of this study was to determine the microclimate in ski boots. Climate chamber tests with five male subjects and field tests with two male subjects were conducted. Temperature and relative humidity were measured using four sensors placed on the foot and one on the liner. Absorbed water in liners and socks was measured with a precision balance. The subjects gave subjective ratings for comfort. The toe sensor temperature dropped below 20 °C at an ambient temperature of 0 °C, -10 °C, and -20 °C. Relative humidity values at the foot were as high as 78% in the climate chamber and 93% in the field. Water absorption in socks and liners ranged from 4 to 10 g in the climate chamber and 19 to 45.5 g in the field. The results reveal the importance of keeping the feet and in particular the toes warm during skiing. One possible improvement may be to construct the liner so that sweat and melted snow are kept as far away as possible from the foot. Liner material with high water absorption capacity and hydrophobic socks were suggested to prevent wet feet.
Collapse
Affiliation(s)
- Patrick Hofer
- Centre of Technology of Ski and Alpine Sport, Fürstenweg 185, 6020 Innsbruck, Austria.
| | - Michael Hasler
- Centre of Technology of Ski and Alpine Sport, Fürstenweg 185, 6020 Innsbruck, Austria.
| | - Gulnara Fauland
- Institute of Textile Chemistry/Physics, University of Innsbruck, Höchsterstraße 73, 6850 Dornbirn, Austria
| | - Thomas Bechtold
- Institute of Textile Chemistry/Physics, University of Innsbruck, Höchsterstraße 73, 6850 Dornbirn, Austria
| | - Werner Nachbauer
- Department of Sport Science, University of Innsbruck, Fürstenweg 185, 6020 Innsbruck, Austria; Centre of Technology of Ski and Alpine Sport, Fürstenweg 185, 6020 Innsbruck, Austria.
| |
Collapse
|
28
|
Trajkovski A, Omerović S, Hribernik M, Prebil I. Failure Properties and Damage of Cervical Spine Ligaments, Experiments and Modeling. J Biomech Eng 2014; 136:031002. [DOI: 10.1115/1.4026424] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2013] [Accepted: 01/06/2014] [Indexed: 11/08/2022]
Abstract
Cervical spine ligaments have an important role in providing spinal cord stability and restricting excessive movements. Therefore, it is of great importance to study the mechanical properties and model the response of these ligaments. The aim of this study is to characterize the aging effects on the failure properties and model the damage of three cervical spine ligaments: the anterior and the posterior longitudinal ligament and the ligamentum flavum. A total of 46 samples of human cadaveric ligaments removed within 24–48 h after death have been tested. Uniaxial tension tests along the fiber direction were performed in physiological conditions. The results showed that aging decreased the failure properties of all three ligaments (failure load, failure elongation). Furthermore, the reported nonlinear response of cervical ligaments has been modeled with a combination of the previously reported hyperelastic and damage model. The model predicted a nonlinear response and damage region. The model fittings are in agreement with the experimental data and the quality of agreement is represented with the values of the coefficient of determination close to 1.
Collapse
Affiliation(s)
- Ana Trajkovski
- Faculty of Mechanical Engineering, University of Ljubljana, Aškerčeva cesta 6, Ljubljana 1000, Slovenia e-mail:
| | - Senad Omerović
- Faculty of Mechanical Engineering, University of Ljubljana, Aškerčeva cesta 6, Ljubljana 1000, Slovenia e-mail:
| | - Marija Hribernik
- Medical Faculty, University of Ljubljana, Vrazov trg 2, Ljubljana 1000, Slovenia e-mail:
| | - Ivan Prebil
- Faculty of Mechanical Engineering, University of Ljubljana, Aškerčeva cesta 6, Ljubljana 1000, Slovenia e-mail:
| |
Collapse
|
29
|
Zirbel SA, Stolworthy DK, Howell LL, Bowden AE. Intervertebral disc degeneration alters lumbar spine segmental stiffness in all modes of loading under a compressive follower load. Spine J 2013; 13:1134-47. [PMID: 23507531 DOI: 10.1016/j.spinee.2013.02.010] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2011] [Revised: 01/24/2013] [Accepted: 02/08/2013] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Previous studies have investigated the relationship between the degeneration grade of the intervertebral disc (IVD) and the flexibility of the functional spinal unit (FSU) but were completed at room temperature without the presence of a compressive follower load. This study builds on previous work by performing the testing under more physiological conditions of a compressive follower load at body temperature and at near 100% humidity. PURPOSE The present work evaluates the effects of IVD degeneration on segmental stiffness, range of motion (ROM), hysteresis area, and normalized hysteresis (hysteresis area/ROM). This study also briefly evaluates the effect of the segment level, temperature, and follower load on the same parameters. STUDY DESIGN In vitro human cadaveric biomechanical investigation. METHODS Twenty-one FSUs were tested in the three primary modes of loading at both body temperature and room temperature in a near 100% humidity environment. A compressive follower load of 440 N was applied to simulate the physiological conditions. Fifteen of the 21 segments were also tested without the follower load to determine the effects of the follower load on segmental biomechanics. The grade of degeneration for each segment was determined using the Thompson scale, and the torque-rotation curves were fit with the Dual-Inflection-Point Boltzmann sigmoid curve. RESULTS Intervertebral disc degeneration resulted in statistically significant changes in segmental stiffness, ROM, and hysteresis area in axial rotation (AR) and lateral bending (LB) and statistically significant changes in ROM and normalized hysteresis in flexion-extension (FE). The progression of these changes with increased degeneration is nonlinear, with changes in the FE and LB tending to respond in concert and opposite to the changes in AR. The lumbosacral joint was significantly stiffer and demonstrated a decreased ROM and hysteresis area as compared with other lumbar segments in AR and LB. Temperature had a significant effect on the stiffness and hysteresis area in AR and on the hysteresis area in LB. Application of a compressive follower load increased the stiffness in all three modes of loading but was significant only in AR and LB. It also reduced the ROM and increased normalized hysteresis in all three modes of loading. CONCLUSIONS The results from this testing quantify the effects of degeneration on spinal biomechanics. Because the testing was conducted under physiological conditions (including a compressive follower load and at body temperature), we expect the measured response to closely match the in vivo response. The testing results can be used to guide the selection of appropriate surgical treatments in the context of IVD degeneration and to validate the mathematical and engineering models of the lumbar spine, including finite element models.
Collapse
Affiliation(s)
- Shannon A Zirbel
- Department of Mechanical Engineering, Brigham Young University, Provo, UT 84602, USA
| | | | | | | |
Collapse
|
30
|
Mattucci SF, Moulton JA, Chandrashekar N, Cronin DS. Strain rate dependent properties of human craniovertebral ligaments. J Mech Behav Biomed Mater 2013; 23:71-9. [DOI: 10.1016/j.jmbbm.2013.04.005] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2012] [Revised: 03/12/2013] [Accepted: 04/02/2013] [Indexed: 11/26/2022]
|
31
|
Lu YC, Untaroiu CD. Effect of storage methods on indentation-based material properties of abdominal organs. Proc Inst Mech Eng H 2012; 227:293-301. [DOI: 10.1177/0954411912468558] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
To investigate the possible changes in material properties of cadaveric abdominal organs due to the preservation methods, the indentation data obtained from porcine abdominal organs (kidney, liver, and spleen) preserved by cooling and freezing are analyzed statistically in this study. Indentation tests were first conducted on fresh specimens. One half of the specimens of each organ were then frozen (preserved at −12 °C), and the other half of the specimens were cooled (preserved at 4 °C). All preserved specimens were retested after 20 days. Force and displacement data recorded during indentation were analyzed using a quasi-linear viscoelastic model. The results show that both cooling and freezing storage increased the kidney stiffness. In contrast, both storage methods decreased the stiffness of the spleen specimens. While cooling increased the liver stiffness, no significant changes of the instantaneous elastic response were observed in the liver specimens preserved by freezing. The liver and spleen’s reduced relaxation responses and the liver’s instantaneous elastic response were significantly different when comparing between cooling and freezing effects after 20 days of preservation. This study showed that both cooling and freezing storage methods significantly changed the material properties of abdominal organs, especially the instantaneous elastic response. More research is needed in investigating the effect of preservation on failure properties and mechanical properties under large deformation.
Collapse
Affiliation(s)
- Yuan-Chiao Lu
- Virginia Tech and Wake Forest University School of Biomedical Engineering and Sciences, Center for Injury Biomechanics, Virginia Tech, Blacksburg, VA, USA
| | - Costin D Untaroiu
- Virginia Tech and Wake Forest University School of Biomedical Engineering and Sciences, Center for Injury Biomechanics, Virginia Tech, Blacksburg, VA, USA
| |
Collapse
|
32
|
Bleakley CM, Costello JT. Do thermal agents affect range of movement and mechanical properties in soft tissues? A systematic review. Arch Phys Med Rehabil 2012; 94:149-63. [PMID: 22885279 DOI: 10.1016/j.apmr.2012.07.023] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2012] [Accepted: 07/25/2012] [Indexed: 10/28/2022]
Abstract
OBJECTIVES To examine the effect of thermal agents on the range of movement (ROM) and mechanical properties in soft tissue and to discuss their clinical relevance. DATA SOURCES Electronic databases (Cochrane Central Register of Controlled Trials, MEDLINE, and EMBASE) were searched from their earliest available record up to May 2011 using Medical Subjects Headings and key words. We also undertook related articles searches and read reference lists of all incoming articles. STUDY SELECTION Studies involving human participants describing the effects of thermal interventions on ROM and/or mechanical properties in soft tissue. Two reviewers independently screened studies against eligibility criteria. DATA EXTRACTION Data were extracted independently by 2 review authors using a customized form. Methodologic quality was also assessed by 2 authors independently, using the Cochrane risk of bias tool. DATA SYNTHESIS Thirty-six studies, comprising a total of 1301 healthy participants, satisfied the inclusion criteria. There was a high risk of bias across all studies. Meta-analyses were not undertaken because of clinical heterogeneity; however, effect sizes were calculated. There were conflicting data on the effect of cold on joint ROM, accessory joint movement, and passive stiffness. There was limited evidence to determine whether acute cold applications enhance the effects of stretching, and further evidence is required. There was evidence that heat increases ROM, and a combination of heat and stretching is more effective than stretching alone. CONCLUSIONS Heat is an effective adjunct to developmental and therapeutic stretching techniques and should be the treatment of choice for enhancing ROM in a clinical or sporting setting. The effects of heat or ice on other important mechanical properties (eg, passive stiffness) remain equivocal and should be the focus of future study.
Collapse
Affiliation(s)
- Chris M Bleakley
- Faculty of Life and Health Sciences, Ulster Sports Academy, University of Ulster, Co Antrim, Ireland.
| | | |
Collapse
|
33
|
Robertson D, Willardson R, Parajuli D, Cannon A, Bowden AE. The lumbar supraspinous ligament demonstrates increased material stiffness and strength on its ventral aspect. J Mech Behav Biomed Mater 2012; 17:34-43. [PMID: 23131792 DOI: 10.1016/j.jmbbm.2012.07.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2012] [Revised: 07/18/2012] [Accepted: 07/27/2012] [Indexed: 12/12/2022]
Abstract
The present work represents the first reported quantified anisotropic, inhomogeneous material constitutive data for the human supraspinous ligament (SSL). Multi-axial material data from 30 human cadaveric SSL samples was collected from distinct locations (dorsal, midsection, and ventral). A structurally motivated strain-energy based continuum model was employed to characterize anisotropic constitutive parameters for each sample. The anisotropic constitutive response correlated well with the reported experimental data (R2>0.97). Results show that in the lumbar spine both the material stiffness and stress at failure were significantly higher in the ventral region of the SSL as compared with the dorsal region (p<0.05). In the along fiber direction a higher stiffness and stress at failure were observed when compared to the transverse direction. These results indicate that modeling spinal ligaments using the hyperelastic line elements that have typically been used may be insufficient to capture their complex material response.
Collapse
Affiliation(s)
- D Robertson
- Brigham Young University, Department of Mechanical Engineering, Provo, UT 84602, USA
| | | | | | | | | |
Collapse
|
34
|
Mattucci SF, Moulton JA, Chandrashekar N, Cronin DS. Strain rate dependent properties of younger human cervical spine ligaments. J Mech Behav Biomed Mater 2012; 10:216-26. [DOI: 10.1016/j.jmbbm.2012.02.004] [Citation(s) in RCA: 86] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2011] [Revised: 01/26/2012] [Accepted: 02/08/2012] [Indexed: 11/28/2022]
|
35
|
Troyer KL, Puttlitz CM. Human cervical spine ligaments exhibit fully nonlinear viscoelastic behavior. Acta Biomater 2011; 7:700-9. [PMID: 20831909 DOI: 10.1016/j.actbio.2010.09.003] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2010] [Revised: 08/27/2010] [Accepted: 09/02/2010] [Indexed: 12/01/2022]
Abstract
Spinal ligaments provide stability and contribute to spinal motion patterns. These hydrated tissues exhibit time-dependent behavior during both static and dynamic loading regimes. Therefore, accurate viscoelastic characterization of these ligaments is requisite for development of computational analogues that model and predict time-dependent spine behavior. The development of accurate viscoelastic models must be preceded by rigorous, empirical evidence of linear viscoelastic, quasi-linear viscoelastic (QLV) or fully nonlinear viscoelastic behavior. This study utilized multiple physiological loading rates (frequencies) and strain amplitudes via cyclic loading and stress relaxation experiments in order to determine the viscoelastic behavior of the human lower cervical spine anterior longitudinal ligament, the posterior longitudinal ligament and the ligamentum flavum. The results indicated that the cyclic material properties of these ligaments were dependent on both strain amplitude and frequency. This strain amplitude-dependent behavior cannot be described using a linear viscoelastic formulation. Stress relaxation experiments at multiple strain magnitudes indicated that the shape of the relaxation curve was strongly dependent on strain magnitude, suggesting that a QLV formulation cannot adequately describe the comprehensive viscoelastic response of these ligaments. Therefore, a fully nonlinear viscoelastic formulation is requisite to model these lower cervical spine ligaments during activities of daily living.
Collapse
|
36
|
Gallagher KM, Howarth SJ, Callaghan JP. Effects of Anterior Shear Displacement Rate on the Structural Properties of the Porcine Cervical Spine. J Biomech Eng 2010; 132:091004. [PMID: 20815638 DOI: 10.1115/1.4001885] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
While the individual tissues of the vertebral joint demonstrate viscoelastic properties, the global viscoelastic properties of the lumbar vertebral joint are not well established. This study investigated how changes in displacement rate influenced the mechanical response of the porcine cervical spine (a surrogate or model for the human lumbar spine) exposed to acute anterior shear failure loading. Thirty porcine cervical spine specimens (15 C3-C4 and 15 C5-C6) were placed under a 1600 N compressive load and subsequently loaded in anterior shear to failure at one of three randomly assigned displacement rates (1 mm/s, 4 mm/s, or 16 mm/s). Ultimate anterior shear force, ultimate displacement, average stiffness, and energy stored until failure were calculated. Load rate in the elastic region was also calculated to compare the load rates used in this study to those used in previous studies. Changes in displacement rate affected the C3-C4 and C5-C6 specimens differently. C5-C6 specimens tested at 16 mm/s had an ultimate force that was 28% and 23% higher than at 1 (p=0.0215) and 4 mm/s (p=0.0461), respectively. The average stiffness to failure of the C5-C6 specimens tested at 16 mm/s was 52% higher than at 4 mm/s (p=0.0289). No such differences were found for the C3-C4 specimens. An increase in the anterior shear displacement rate did not necessarily demonstrate viscoelasticity of the vertebral joint. Specimen intervertebral levels were affected differently by changes in anterior shear displacement rate, which may have been a result of anatomical and postural differences between the two levels. Future studies should further investigate the effect of displacement rate on the spine and the inconsistencies between different specimen levels.
Collapse
Affiliation(s)
- Kaitlin M. Gallagher
- Department of Kinesiology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Samuel J. Howarth
- Department of Kinesiology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Jack P. Callaghan
- Department of Kinesiology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
37
|
Williams JM, Haq I, Lee RY. Is pain the cause of altered biomechanical functions in back pain sufferers? Hum Mov Sci 2010; 29:311-25. [DOI: 10.1016/j.humov.2009.12.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2009] [Revised: 11/30/2009] [Accepted: 12/01/2009] [Indexed: 11/15/2022]
|
38
|
Ambrosetti-Giudici S, Gédet P, Ferguson SJ, Chegini S, Burger J. Viscoelastic properties of the ovine posterior spinal ligaments are strain dependent. Clin Biomech (Bristol, Avon) 2010; 25:97-102. [PMID: 19931955 DOI: 10.1016/j.clinbiomech.2009.10.017] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2009] [Revised: 10/28/2009] [Accepted: 10/29/2009] [Indexed: 02/07/2023]
Abstract
BACKGROUND The biomechanical role of the posterior spinal ligaments for spinal stability has been stated in previous studies. The investigation of the viscoelastic properties of human lumbar spinal ligaments is essential for the understanding of physiological differences between healthy and degenerated tissues. The stress-relaxation behavior of biological tissues is commonly described with the quasi-linear viscoelastic model of Fung, which assumes that the stress-relaxation response is independent of the applied strain. The goal of this study was to investigate the stress-relaxation response of ovine posterior spinal ligaments at different elongations to verify the above-mentioned hypothesis. METHODS Twenty-four ovine lumbar spinal segments, consisting of only the supraspinous and interspinous ligaments and adjoining spinous processes, were elongated uniaxially to different strain levels within the physiological elastic region (5-20%). The experimental data were described with a non-linear viscoelastic model: the modified superposition method of Findley. FINDINGS A linear dependency of the relaxation rate to the applied strains was observed on intact segments, when both ligaments were considered, as well as on each individual ligament. This result can be applied to the human spinal ligaments, due to similarities observed between the sheep and human spinal segment under physiological loading. INTERPRETATION The non-linear viscoelastic modified superposition method of Findley is an appropriate model for describing the viscoelastic properties of lumbar spinal ligaments in vitro due to its ability to address variation in applied strain during the force relaxation measurements.
Collapse
|
39
|
Serrat MA, Williams RM, Farnum CE. Temperature alters solute transport in growth plate cartilage measured by in vivo multiphoton microscopy. J Appl Physiol (1985) 2009; 106:2016-25. [PMID: 19372302 DOI: 10.1152/japplphysiol.00295.2009] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Solute delivery to avascular cartilaginous plates is critical to bone elongation, and impaired transport of nutrients and growth factors in cartilage matrix could underlie many skeletal abnormalities. Advances in imaging technology have revolutionized our ability to visualize growth plates in vivo, but quantitative methods are still needed. We developed analytical standards for measuring solute delivery, defined by amount and rate of intravenous tracer entry, in murine growth plates using multiphoton microscopy. We employed an acute temperature model because of its well-established impact on bone circulation and tested the hypothesis that solute delivery changes positively with limb temperature when body core and respiration are held constant (36 degrees C, 120 breaths/min). Tibial growth plates were surgically exposed in anesthetized 5-wk-old mice, and their hindlimbs were immersed in warm (36 degrees C) or cool (23 degrees C) saline (n = 6/group). After 30 min of thermal equilibration, we administered an intracardiac injection of fluorescein (50 microl, 0.5%) and captured sequentially timed growth plate images spanning 10 min at standardized depth. Absolute growth plate fluorescence was normalized to vascular concentrations for interanimal comparisons. As predicted, more fluorescein infiltrated growth plates at 36 degrees C, with standardized values nearly double those at 23 degrees C. Changing initial limb temperature did not alter baseline values, suggesting a sustained response period. These data validate the sensitivity of our system and have relevance to strategies for enhancing localized delivery of therapeutic agents to growth plates of children. Applications of this technique include assessment of solute transport in models of growth plate dysfunction, particularly chondrodysplasias with matrix irregularities.
Collapse
Affiliation(s)
- Maria A Serrat
- Cornell University, Department of Biomedical Sciences, Ithaca, NY 14853-6401, USA.
| | | | | |
Collapse
|
40
|
Huang CY, Wang VM, Flatow EL, Mow VC. Temperature-dependent viscoelastic properties of the human supraspinatus tendon. J Biomech 2009; 42:546-9. [PMID: 19159888 DOI: 10.1016/j.jbiomech.2008.11.013] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2008] [Revised: 10/30/2008] [Accepted: 11/19/2008] [Indexed: 11/29/2022]
Abstract
Temperature effects on the viscoelastic properties of the human supraspinatus tendon were investigated using static stress-relaxation experiments and the quasi-linear viscoelastic (QLV) theory. Twelve supraspinatus tendons were randomly assigned to one of two test groups for tensile testing using the following sequence of temperatures: (1) 37, 27, and 17 degrees C (Group I, n=6), or (2) 42, 32, and 22 degrees C (Group II, n=6). QLV parameter C was found to increase at elevated temperatures, suggesting greater viscous mechanical behavior at higher temperatures. Elastic parameters A and B showed no significant difference among the six temperatures studied, implying that the viscoelastic stress response of the supraspinatus tendon is not sensitive to temperature over shorter testing durations. Using regression analysis, an exponential relationship between parameter C and test temperature was implemented into QLV theory to model temperature-dependent viscoelastic behavior. This modified approach facilitates the theoretical determination of the viscoelastic behavior of tendons at arbitrary temperatures.
Collapse
Affiliation(s)
- Chun-Yuh Huang
- Department of Biomedical Engineering, University of Miami, 219A McArthur Annex, 1251 Memorial Drive, Coral Gables, FL 33146, USA
| | | | | | | |
Collapse
|