Mungalsingh MA, Thompson B, Peterson SD, Murphy PJ. Stimulus characteristics of a novel air-based multiple stimulus aesthesiometer. Ophthalmic Physiol Opt 2024; 44:32-41. [PMID: 37994563 DOI: 10.1111/opo.13252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 10/24/2023] [Accepted: 10/31/2023] [Indexed: 11/24/2023]
Abstract
PURPOSE To identify the stimulus airflow characteristics and confirm the consistency of a novel air jet-based aesthesiometer capable of producing and applying multiple stimuli separated either by time and/or by space. METHODS A novel aesthesiometer (Dolphin Aesthesiometer) was designed around a micro-blower under software management. Two nozzle attachments assisted in airflow control (flexible tube 1.6 mm diameter; brass tube 0.5 mm diameter). Four studies that tested the characteristics of the airflow and stimulus consistency were completed: (i) airflow pattern/trajectory, (ii) airflow surface dispersion, (iii) force of airflow across a range of stimulus strengths and (iv) thermal effects on the ocular surface. RESULTS Stimulus characteristic studies revealed: (i) airflow is coherent within the expected test distance range for the instrument, and spread rate is constant irrespective of stimulus strength; (ii) airflow dispersion occurs upon encountering a surface and dispersion increases with increasing airflow rate; (iii) a consistent and small force (10-4 N) is applied by the airflow and (iv) repeatable thermal effects occur in relation to the airflow, and the mode of stimulation of the Dolphin aesthesiometer is predominantly thermal in nature. CONCLUSIONS These studies confirm the repeatability and consistency of the novel instrument. The device is suitable for measuring corneal sensitivity. The availability of additional air jets allows the application of multiple stimuli to facilitate corneal summation investigations.
Collapse
Affiliation(s)
- Melanie A Mungalsingh
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Benjamin Thompson
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
- Center for Eye and Vision Research, Hong Kong, China
| | - Sean D Peterson
- Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Paul J Murphy
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
2
|
Pastor-Zaplana JÁ, Gallar J, Acosta MC. Functional Changes of the Ocular Surface Sensory Nerves Due to Contact Lens Use in Young Symptomatic and Asymptomatic Users. Invest Ophthalmol Vis Sci 2023; 64:12. [PMID: 37938935 PMCID: PMC10637199 DOI: 10.1167/iovs.64.14.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 10/18/2023] [Indexed: 11/10/2023] Open
Abstract
Purpose The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users. Methods CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 13 (n = 14) or CL-A. Users of eye glasses (EG; 24.5 ± 0.8 years, n = 29) with OSDI < 13 participated as controls. The sensations evoked by mechanical, chemical (gas esthesiometer), and cold (4°C saline drops) stimuli were measured using the Visual Analogue Scales (VASs). Moreover, tear volume, tear break up time (TBUT), blinking frequency (BF), and ocular surface temperature (OST; IR thermography) were also measured. Results Mechanical and chemical stimuli produced similar scores in the CL-A and EG participants, although the CL-A subjects referred to stronger irritation (p < 0.05). Likewise, the VAS intensity in response to cold stimuli did not differ between CL-A and EG subjects, while the ability to detect cold was significantly worse in CL-S users (p < 0.05). CL-A users had a similar tear volume, a higher BF (p < 0.01) and shorter TBUT (p < 0.001) to EG wearers, and blinking and TBUT were also altered significantly in CL-S users (p < 0.01). Interestingly, the OST was significantly lower in CL-A users (p < 0.05) than in EG wearers, but not in CL-S users. Conclusions Using CLs modifies corneal sensitivity, blinking and tearing in young volunteers. Even if they have yet to develop clinical signs of inflammation, they display changes in corneal sensitivity consistent with the sensitization of corneal nociceptors and the inhibition cold thermoreceptors, phenomena that occur under inflammatory conditions. The differences in corneal sensitivity and OST between CL-A and CL-S users could reflect the extent of nerve damage and inflammation at the ocular surface.
Collapse
Affiliation(s)
- José Ángel Pastor-Zaplana
- Instituto de Neurociencias, Universidad Miguel Hernández-CSIC, Sant Joan d'Alacant, Spain
- Departamento de Patología y Cirugía, Universidad Miguel Hernández de Elche, Sant Joan d'Alacant, Spain
| | - Juana Gallar
- Instituto de Neurociencias, Universidad Miguel Hernández-CSIC, Sant Joan d'Alacant, Spain
- Instituto de Investigación Biomédica y Sanitaria de Alicante, Alicante, Spain
| | - M. Carmen Acosta
- Instituto de Neurociencias, Universidad Miguel Hernández-CSIC, Sant Joan d'Alacant, Spain
| |
Collapse
|
3
|
Nosch DS, Käser E, Christen A, Schinzel J, Joos RE. Corneal sensitivity in silicone hydrogel and rigid gas permeable contact lens wear. Cont Lens Anterior Eye 2023; 46:101888. [PMID: 37422380 DOI: 10.1016/j.clae.2023.101888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 05/08/2023] [Accepted: 06/28/2023] [Indexed: 07/10/2023]
Abstract
PURPOSE The aim of this prospective cross-sectional cohort study was to test the effect of silicone hydrogel (SH) and rigid gas permeable (RGP) contact lens (CL) wear on corneal sensitivity, applying the new Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) and the Cochet-Bonnet (CB) aesthesiometer, based on subject feedback (psychophysical method). METHODS Participants were recruited for three equally large groups: Group A (SH CL), Group B (RGP CL) and Group C (non-CL wearers). Inclusion criteria were healthy eyes and OSDI ≤ 13. Corneal sensory thresholds were determined twice during two visits, with aid of SLACS and CB. RESULTS 96 participants completed the study (n = 33 in groups A and C, n = 30 in group B); average age in group A: 27.42 ± 6.83 years, group B: 36.90 ± 9.68 years and group C: 26.06 ± 6.19 years. No statistically significant difference in corneal sensitivity was observed between the three groups for either method (p = 0.302 for SLACS, p = 0.266 for CB; Kruskal-Wallis rank sum test). Higher CSTs were obtained for males than for females in both CL groups with SLACS, and with CB only in the RGP CL group (p = 0.041 in Group A, p = 0.006 in Group B with SLACS; p = 0.041 in Group B with CB; bootstrap analysis with age correction and gender balancing). No correlation was observed between CL comfort and corneal sensitivity for neither method applied (for SLACS r = 0.097 and p = 0.51, for CB r = 0.17 and p = 0.15; robust linear mixed model). CONCLUSIONS No difference in corneal sensitivity with CL compared to non-CL wear was noted in this study. However, lower levels of corneal sensitivity were observed in the male CL groups, warranting further investigation.
Collapse
Affiliation(s)
- Daniela S Nosch
- Institute of Optometry, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), Olten, Switzerland; ELZA Institute AG, Dietikon, Switzerland.
| | - Emanuele Käser
- Institute of Optometry, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), Olten, Switzerland
| | - Alice Christen
- Institute of Optometry, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), Olten, Switzerland; Eye Hospital, Cantonal Hospital Lucerne, Luzern, Switzerland
| | - Julia Schinzel
- Institute of Optometry, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), Olten, Switzerland; ELZA Institute AG, Dietikon, Switzerland
| | - Roland E Joos
- Institute of Optometry, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), Olten, Switzerland
| |
Collapse
|
4
|
Ishihara K, Shi X, Fukazawa K, Yamaoka T, Yao G, Wu JY. Biomimetic-Engineered Silicone Hydrogel Contact Lens Materials. ACS APPLIED BIO MATERIALS 2023; 6:3600-3616. [PMID: 37616500 PMCID: PMC10521029 DOI: 10.1021/acsabm.3c00296] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 08/16/2023] [Indexed: 08/26/2023]
Abstract
Contact lenses are one of the most successful applications of biomaterials. The chemical structure of the polymers used in contact lenses plays an important role in determining the function of contact lenses. Different types of contact lenses have been developed based on the chemical structure of polymers. When designing contact lenses, materials scientists consider factors such as mechanical properties, processing properties, optical properties, histocompatibility, and antifouling properties, to ensure long-term wear with minimal discomfort. Advances in contact lens materials have addressed traditional issues such as oxygen permeability and biocompatibility, improving overall comfort, and duration of use. For example, silicone hydrogel contact lenses with high oxygen permeability were developed to extend the duration of use. In addition, controlling the surface properties of contact lenses in direct contact with the cornea tissue through surface polymer modification mimics the surface morphology of corneal tissue while maintaining the essential properties of the contact lens, a significant improvement for long-term use and reuse of contact lenses. This review presents the material science elements required for advanced contact lenses of the future and summarizes the chemical methods for achieving these goals.
Collapse
Affiliation(s)
- Kazuhiko Ishihara
- Division
of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871, Japan
| | - Xinfeng Shi
- Alcon
Research, LLC, Fort Worth, Texas 76134, United States
| | - Kyoko Fukazawa
- National
Cerebral and Cardiovascular Center Research Institute, Suita, Osaka 564-8565, Japan
| | - Tetsuji Yamaoka
- National
Cerebral and Cardiovascular Center Research Institute, Suita, Osaka 564-8565, Japan
| | - George Yao
- Alcon
Research, LLC, Duluth, Georgia 30097, United States
| | | |
Collapse
|
5
|
Waghmare SV, Jeria S. A Review of Contact Lens-Related Risk Factors and Complications. Cureus 2022; 14:e30118. [PMID: 36381898 PMCID: PMC9644230 DOI: 10.7759/cureus.30118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 10/10/2022] [Indexed: 11/05/2022] Open
Abstract
The purpose of this article is to develop a modern strategy for handling difficulties related to contact lenses and their care. A growing number of people throughout the world are currently concerned by eye-related undesirable activities in allergy sufferers and those wearing contact lenses. While many wearers who experience ocular discomfort exhibit dryness as a symptom, many other contact lens-related pain symptoms also include irritation and fatigue, and managing coexisting diseases must be done in accordance with aspects of wearing contact lenses, all of which undoubtedly increase discomfort. It is typical for contact lens storage containers to have persistent microbial contamination, which has been linked to microbial keratitis (MK) and clear corneal invasion. Contact lens-associated MK is an interesting, potentially sight-threatening complexity arising from wearing soft contact lenses. Estimates show that for every 10,000 persons who wear contact lenses each year, there are 2 to 5 occurrences of MK. Investigating separate determinants for contact lens-associated MK and evaluating their impact on infection load is one of the challenges in their administration. It is hoped that this will offer a useful outline of the complicated issues of contact lens wear that are both infectious and non-infectious. Recent epidemiological studies detailing the risk factors associated with contact lens use, and the effect of pathogen and individual immune profiles on the severity of diseases have enlightened how we might interpret the prophylaxis and prevention of contact lens-related corneal infection. The most dreaded side effect of contact lens use, infectious keratitis linked with contact lenses, will be reviewed, along with the most recent advancements in its diagnosis and treatment.
Collapse
|
6
|
Abstract
The review provides basic information about embryology, structural features, biochemical composition, functions and classification of corneal nerve fibers, and describes anatomical, histological and functional diagnostic techniques for corneal nerves. Each method for analyzing the structure of the nerve fiber, its advantages and disadvantages are described in detail, including the history of the development of confocal microscopy (laser and light) and esthesiometry (contact and non-contact). The article also presents the criteria according to which the structure of the nerve fiber is estimated using laser confocal microscopy, and the shortcomings of these criteria. Additionally, the article reports on the futility of the use of modern esthesiometry methods.
Collapse
Affiliation(s)
- Z V Surnina
- Research Institute of Eye Diseases, Moscow, Russia
| |
Collapse
|
7
|
Nosch DS, Joos RE, Müller D, Matt SM. General pain perception sensitivity, lid margin sensitivity and gas permeable contact lens comfort. Clin Exp Optom 2021; 103:766-771. [DOI: 10.1111/cxo.12995] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Revised: 09/03/2019] [Accepted: 10/01/2019] [Indexed: 12/01/2022] Open
Affiliation(s)
- Daniela S Nosch
- Institute of Optometry, School of Engineering, University of Applied Sciences (FHNW), Olten, Switzerland,
| | - Roland E Joos
- Institute of Optometry, School of Engineering, University of Applied Sciences (FHNW), Olten, Switzerland,
| | - Dominik Müller
- Institute of Optometry, School of Engineering, University of Applied Sciences (FHNW), Olten, Switzerland,
- Büchi Optik Affoltern GmbH, Affoltern am Albis, Switzerland,
| | - Stefanie M Matt
- Institute of Optometry, School of Engineering, University of Applied Sciences (FHNW), Olten, Switzerland,
- Brillen‐Trotter AG, Aarau, Switzerland,
| |
Collapse
|
8
|
Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye 2021; 44:192-219. [PMID: 33775377 DOI: 10.1016/j.clae.2021.02.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/19/2022]
Abstract
This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK.
| | - Paul J Murphy
- University of Waterloo, School of Optometry and Vision Science, Waterloo, Canada
| | - Kate L Gifford
- School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Paul Gifford
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Leah Johnson
- CooperVision Specialty EyeCare, Gilbert, AZ, United States
| | - Dimitra Makrynioti
- School of Health Rehabilitation Sciences, University of Patras (Aigio), Greece
| | - Amir M Moezzi
- Centre for Ocular Research and Education, University of Waterloo, Canada
| | - Kurt Moody
- Johnson & Johnson Vision Care, Jacksonville, FL, United States
| | | | | | - Kasandra Swiderska
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | | | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
9
|
Abstract
OBJECTIVES Many contact lens (CL) users permanently discontinue wear because of ocular dryness and discomfort. This study aimed to determine whether refitting symptomatic soft CL wearers in to orthokeratology could improve ocular symptoms and signs. METHODS This was a prospective, 3-month, open-label study of symptomatic (Contact Lens Dry Eye Questionnaire [CLDEQ-8] ≥12) soft CL wearers who were between the ages of 18 and 45 years. All subjects were refit into orthokeratology CLs (Emerald, Euclid Systems). The following tests were completed: CL history, Standardized Patient Evaluation of Eye Dryness (SPEED) questionnaire, CLDEQ-8, CLDEQ-4, logarithm of the minimum angle of resolution visual acuity, pupil size, refractive error, slit-lamp biomicroscopy, noninvasive tear break-up time, tear meniscus height, phenol red thread, conjunctival staining, corneal aesthesiometry, and corneal topography. RESULTS Twenty-nine of 40 qualifying subjects (age=24.43±4.62 years) completed the study. No significant differences were detected between completed and noncomplete subjects. Completed subjects had significantly better CLDEQ-8, CLDEQ-4, and SPEED scores at 3 months compared with baseline. Completed subjects had significantly better conjunctival staining scores and flatter keratometry values at 1 month compared with baseline. CONCLUSIONS Although not all symptomatic soft CL wearers were able to be refit into orthokeratology, subjects who were wearing orthokeratology at 3 months had a significant and clinically meaningful improvement in ocular symptoms. Additional work is needed to determine the mechanism leading to improved comfort because few clinical signs were changed after switching to orthokeratology.
Collapse
|
10
|
Sánchez-García A, Ariza MA, Büchler P, Molina-Martin A, Piñero DP. Structural changes associated to orthokeratology: A systematic review. Cont Lens Anterior Eye 2020; 44:101371. [DOI: 10.1016/j.clae.2020.10.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 08/31/2020] [Accepted: 10/03/2020] [Indexed: 12/16/2022]
|
11
|
Topical Review: Effects of Contact Lens Wear on Corneal, Conjunctival, and Lid Margin Sensitivity. Optom Vis Sci 2019; 96:790-801. [DOI: 10.1097/opx.0000000000001429] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
12
|
Sensory Adaptation to Silicone Hydrogel Contact Lens Wear Is Not Associated With Alterations in the Corneal Subbasal Nerve Plexus. Cornea 2019; 38:1142-1146. [PMID: 31232743 DOI: 10.1097/ico.0000000000002031] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
PURPOSE To evaluate corneal subbasal nerve alterations in contact lens (CL)-naive silicone hydrogel CL wearers and to investigate the relationship between structural subbasal nerve changes with corneal sensitivity. METHODS Twenty eyes of 20 neophyte daily silicone hydrogel CL wearers and 20 eyes of age-matched control subjects were recruited for this prospective longitudinal study. Corneal subbasal nerve densities were evaluated using in vivo confocal microscopy. Central corneal tactile sensitivity was measured using Cochet-Bonnet esthesiometers. In vivo confocal microscopy and Cochet-Bonnet esthesiometry were performed before and at the 6-month time point after the initiation of CL wear. Two-way repeated measures analysis of variance, χ, and Wilcoxon signed-rank tests were used for statistical analyses. RESULTS The mean ages of CL users and control subjects were 21.8 ± 1.8 years (range = 19-24 years) and 21.5 ± 2.3 years (range = 20-24 years), respectively (P = 0.579). Compared with their baseline values, there were no significant changes at the 6-month follow-up period in the mean total subbasal nerve fiber length (2266.6 ± 414.6 vs. 2277.9 ± 405.0 μm/frame; P = 0.432), mean total subbasal nerve branch density (10.4 ± 1.5 vs. 10.5 ± 1.3 nerves/frame; P = 0.655), or the mean long nerve fiber density (4.7 ± 0.7 vs. 4.8 ± 0.7 nerves/frame; P = 0.564) of CL users. Mechanical corneal sensitivity remained unaltered during the 6-month period in CL users (11.2 ± 0.5 vs. 11.2 ± 0.5; P = 1.000). No significant changes were observed in the subbasal nerve plexus or corneal tactile sensitivity of the control subjects during the study interval. CONCLUSIONS Sensory adaptation to CL wear is not mediated through attenuation of the subbasal nerve or reduction of corneal tactile sensitivity in CL-naive users.
Collapse
|
13
|
Short-Term Effects of Overnight Orthokeratology on Corneal Sensitivity in Chinese Children and Adolescents. J Ophthalmol 2018; 2018:6185919. [PMID: 30671260 PMCID: PMC6323471 DOI: 10.1155/2018/6185919] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 11/24/2018] [Indexed: 12/13/2022] Open
Abstract
Purpose To assess the effects of the 3-month period of orthokeratology (OK) treatment on corneal sensitivity in Chinese children and adolescents. Methods Thirty subjects wore overnight OK lenses in both eyes for 3 months and were assessed at baseline, 1 day, 1 week, 1 month, and 3 months after the treatment. Changes in corneal sensitivity were measured by the Cochet–Bonnet (COBO) esthesiometer at the corneal apex and approximately 2 mm from the temporal limbus. Changes in refraction and corneal topography were also measured. Results Central corneal sensitivity suffered a significant reduction within the first month of the OK treatment period but returned to the baseline level at three months (F = 3.009, P=0.039), while no statistically significant difference occurred in temporal sensitivity (F = 2.462, P=0.074). The baseline of central corneal sensitivity correlated with age (r = −0.369, P=0.045). A marked change in refraction (uncorrected visual acuity, P < 0.001; spherical equivalent, P < 0.001) and corneal topographical condition (mean keratometry reading, P < 0.001; eccentricity value, P < 0.001; Surface Regularity Index, P < 0.001) occurred, but none of these measurements were correlated with corneal sensitivity. Conclusions A 3-month period OK treatment causes a reduction in central corneal sensitivity in Chinese children and adolescents but with a final recovery to the baseline level, which might be because neuronal adaptation occurred earlier in children and adolescents than in adults.
Collapse
|
14
|
Abstract
The purpose of this article is to provide a review of existing literature describing complications with contemporary contact lenses and their management. It is envisioned that this will serve as a useful summary of noninfectious and infectious complications associated with contact lens wear.
Collapse
|
15
|
Short-Term Effects of Overnight Orthokeratology on Corneal Sub-basal Nerve Plexus Morphology and Corneal Sensitivity. Eye Contact Lens 2018; 44:77-84. [PMID: 27243354 DOI: 10.1097/icl.0000000000000282] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To assess the effects of a short period of orthokeratology (OK) on corneal sub-basal nerve plexus (SBNP) morphology and corneal sensitivity. METHODS Measurements were made in 56 right eyes of 56 subjects with low-to-moderate myopia who wore 2 OK lens designs (Group CRT: HDS 100 Paragon CRT, n=35; Group SF: Seefree; n=21) for a period of 1 month and in 15 right eyes of noncontact lens wearers as controls. The variables determined in each participant were corneal sensitivity using a Cochet-Bonnet esthesiometer and 12 SBNP variables determined on laser scanning confocal microscopy images using 3 different software packages. Correlation between SBNP architecture and corneal sensitivity was also examined. RESULTS Few changes were observed over the 1-month period in the variables examined in the OK treatment and control groups. However, significant reductions were detected over time in the number of nerves in the central cornea in the groups CRT (P=0.029) and SF (P=0.043) and in central corneal sensitivity in CRT (P=0.047) along with significant increases in central and midperipheral corneal Langerhans cell counts in SF (P=0.001 and 0.048, respectively). CONCLUSIONS This study provides useful data to better understand the anatomical changes induced by OK in corneal SBNP. The different response observed to the 2 OK lens designs requires further investigation.
Collapse
|
16
|
Long-Term Impacts of Orthokeratology Treatment on Sub-Basal Nerve Plexus and Corneal Sensitivity Responses and Their Reversibility. Eye Contact Lens 2018; 44:91-96. [DOI: 10.1097/icl.0000000000000386] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
17
|
Abstract
PURPOSE To examine the cooling thresholds and the estimated sensation magnitude at stimulus detection in controls and symptomatic and asymptomatic contact lens (CL) wearers, to determine whether detection thresholds depend on the presence of symptoms of dryness and discomfort. METHODS Forty-nine adapted CL wearers and 15 non-lens wearing controls had room temperature pneumatic thresholds measured using a custom Belmonte esthesiometer, during Visits 1 and 2 (Baseline CL), Visit 3 (2 weeks no CL wear), and Visit 4 (2 weeks after resuming CL wear). CL wearers were subdivided into symptomatic and asymptomatic groups based on comfortable wearing time (CWT) and CLDEQ-8 score (<8 hours CWT and ≥14 CLDEQ-8 stratified the symptom groups). Detection thresholds were estimated using an ascending method of limits and each threshold was the average of the three first-reported flow rates. The magnitude of intensity, coolness, irritation, and pain at detection of the stimulus were estimated using a 1-100 scale (1 very mild, 100 very strong). RESULTS In all measurement conditions, the symptomatic CL wearers were the most sensitive, the asymptomatic CL wearers were the least sensitive, and the control group was between the two CL wearing groups (group factor p < 0.001, post hoc asymptomatic vs. symptomatic group, all p's < 0.015). Similar patterns were found for the estimated magnitude of intensity and irritation (group effect p = 0.027 and 0.006 for intensity and irritation, respectively) but not for cooling (p > 0.05) at detection threshold. CONCLUSIONS Symptomatic CL wearers have higher cold detection sensitivity and report greater intensity and irritation sensation at stimulus detection than the asymptomatic wearers. Room temperature pneumatic esthesiometry may help to better understand the process of sensory adaptation to CL wear.
Collapse
|
18
|
Boost M, Cho P, Wang Z. Disturbing the balance: effect of contact lens use on the ocular proteome and microbiome. Clin Exp Optom 2017; 100:459-472. [PMID: 28771841 DOI: 10.1111/cxo.12582] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2017] [Revised: 05/29/2017] [Accepted: 06/05/2017] [Indexed: 12/17/2022] Open
Abstract
Contact lens wear is a popular, convenient and effective method for vision correction. In recent years, contact lens practice has expanded to include new paradigms, including orthokeratology; however, their use is not entirely without risk, as the incidence of infection has consistently been reported to be higher in contact lens wearers. The explanations for this increased susceptibility have largely focused on physical damage, especially to the cornea, due to a combination of hypoxia, mechanical trauma, deposits and solution cytotoxicity, as well as poor compliance with care routines leading to introduction of pathogens into the ocular environment. However, in recent years, with the increasing availability and reduced cost of molecular techniques, the ocular environment has received greater attention with in-depth studies of proteins and other components. Numerous proteins were found to be present in the tears and their functions and interactions indicate that the tears are far more complex than formerly presumed. In addition, the concept of a sterile or limited microbial population on the ocular surface has been challenged by analysis of the microbiome. Ocular microbiome was not considered as one of the key sites for the Human Microbiome Project, as it was thought to be limited compared to other body sites. This was proven to be fallacious, as a wide variety of micro-organisms were identified in the analyses of human tears. Thus, the ocular environment is now recognised to be more complicated and interference with this ecological balance may lead to adverse effects. The use of contact lenses clearly changes the situation at the ocular surface, which may result in consequences which disturb the balance in the healthy eye.
Collapse
Affiliation(s)
- Maureen Boost
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong.,Squina International Centre for Infection Control, Hong Kong
| | - Pauline Cho
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong.,Squina International Centre for Infection Control, Hong Kong
| | - Zhaoran Wang
- School of Optometry, The Hong Kong Polytechnic University, Hong Kong
| |
Collapse
|
19
|
Abstract
PURPOSE To determine tear neuropeptide levels in contact lens wearers and non-wearers, and to examine relationships with indices of corneal innervation, tear function, and ocular discomfort. METHODS A cross-sectional, single-visit, investigator-masked pilot study. Assessments included Ocular Comfort Index (OCI), central and mid-peripheral corneal nerve density and morphology (HRT-Rostock), corneal sensitivity (Cochet-Bonnet aesthesiometer), tear Substance P and calcitonin gene-related peptide (CGRP) concentration (ELISA), in situ tear osmolarity (TearLab), tear secretion (Phenol Red Thread), and noninvasive tear break-up time (NITBUT; Keeler Tearscope). Groups were compared using independent t-test or Mann-Whitney U test, and regional differences assessed using paired t-tests. Associations were analyzed using Pearson or Spearman correlation. Significance was determined at P < .05. RESULTS Twenty contact lens wearers (7M:13F, 32 ± 5 years) and 20 non-wearers (7M:13F, 31 ± 5 years) completed the study. OCI score was numerically higher in lens wearers (32.27 ± 5.33) than non-wearers (27.66 ± 9.94). Tear osmolarity was higher [298.0 (IQR 291.0-309.8) vs. 288.5 (282.3-298.3) mOsmol/L; P = .01] whereas NITBUT was lower (9.8 ± 3.4 vs. 13.8 ± 5.6 s; P = .01) in lens wearers compared with non-wearers. Tear neuropeptide concentrations were not different between groups [Substance P 4.29 ng/ml (IQR 1.57-6.05), CGRP 14.89 ng/ml (5.08-59.26)], and there were no differences in nerve morphology or ocular surface sensitivity. Higher nerve density, interconnections, and tortuosity were observed in the central cornea than mid-peripherally (P < .05). OCI score was moderately associated with nerve tortuosity (r = 0.42, P = .01). CGRP was associated with central nerve density (ρ = 0.38, P = .02), as was tear secretion (r = -0.37, P = .02). Nerve interconnections were strongly associated with corneal sensitivity (ρ = 0.64, P < .001). CONCLUSIONS Relationships were demonstrated between nerve density, tear CGRP, and corneal sensitivity. Markers of corneal neurobiology and sensory function do not appear to be altered in contact lens wear despite worse tear function (osmolarity and stability) in lens wearers. This suggests that mechanisms other than overt changes in corneal innervation regulate tear function during lens wear. The relationship between nerve tortuosity and ocular discomfort requires elucidation.
Collapse
|
20
|
Reduced Corneal Sensitivity and Sub-Basal Nerve Density in Long-Term Orthokeratology Lens Wear. Eye Contact Lens 2017; 43:218-224. [DOI: 10.1097/icl.0000000000000285] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
21
|
Lum E, Golebiowski B, Swarbrick HA. Changes in corneal subbasal nerve morphology and sensitivity during orthokeratology: Recovery of change. Ocul Surf 2017; 15:236-241. [DOI: 10.1016/j.jtos.2017.01.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Revised: 01/20/2017] [Accepted: 01/21/2017] [Indexed: 11/29/2022]
|
22
|
Changes in Corneal Subbasal Nerve Morphology and Sensitivity During Orthokeratology: Onset of Change. Ocul Surf 2017; 15:227-235. [DOI: 10.1016/j.jtos.2016.07.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Revised: 07/15/2016] [Accepted: 07/23/2016] [Indexed: 11/23/2022]
|
23
|
Cruzat A, Qazi Y, Hamrah P. In Vivo Confocal Microscopy of Corneal Nerves in Health and Disease. Ocul Surf 2017; 15:15-47. [PMID: 27771327 PMCID: PMC5512932 DOI: 10.1016/j.jtos.2016.09.004] [Citation(s) in RCA: 207] [Impact Index Per Article: 29.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2016] [Revised: 09/19/2016] [Accepted: 09/25/2016] [Indexed: 12/20/2022]
Abstract
In vivo confocal microscopy (IVCM) is becoming an indispensable tool for studying corneal physiology and disease. Enabling the dissection of corneal architecture at a cellular level, this technique offers fast and noninvasive in vivo imaging of the cornea with images comparable to those of ex vivo histochemical techniques. Corneal nerves bear substantial relevance to clinicians and scientists alike, given their pivotal roles in regulation of corneal sensation, maintenance of epithelial integrity, as well as proliferation and promotion of wound healing. Thus, IVCM offers a unique method to study corneal nerve alterations in a myriad of conditions, such as ocular and systemic diseases and following corneal surgery, without altering the tissue microenvironment. Of particular interest has been the correlation of corneal subbasal nerves to their function, which has been studied in normal eyes, contact lens wearers, and patients with keratoconus, infectious keratitis, corneal dystrophies, and neurotrophic keratopathy. Longitudinal studies have applied IVCM to investigate the effects of corneal surgery on nerves, demonstrating their regenerative capacity. IVCM is increasingly important in the diagnosis and management of systemic conditions such as peripheral diabetic neuropathy and, more recently, in ocular diseases. In this review, we outline the principles and applications of IVCM in the study of corneal nerves in various ocular and systemic diseases.
Collapse
Affiliation(s)
- Andrea Cruzat
- Cornea & Refractive Surgery Service, Department of Ophthalmology, Massachusetts Eye & Ear Infirmary, Harvard Medical School, Boston, MA, USA; Department of Ophthalmology, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Yureeda Qazi
- Cornea & Refractive Surgery Service, Department of Ophthalmology, Massachusetts Eye & Ear Infirmary, Harvard Medical School, Boston, MA, USA
| | - Pedram Hamrah
- Cornea & Refractive Surgery Service, Department of Ophthalmology, Massachusetts Eye & Ear Infirmary, Harvard Medical School, Boston, MA, USA; Boston Image Reading Center, Tufts Medical Center, Tufts University School of Medicine, Boston, MA; Cornea Service, New England Eye Center, Department of Ophthalmology, Tufts Medical Center, Tufts University School of Medicine, Boston, MA.
| |
Collapse
|
24
|
Differences in Dry Eye Questionnaire Symptoms in Two Different Modalities of Contact Lens Wear: Silicone-Hydrogel in Daily Wear Basis and Overnight Orthokeratology. BIOMED RESEARCH INTERNATIONAL 2016; 2016:1242845. [PMID: 27689073 PMCID: PMC5022233 DOI: 10.1155/2016/1242845] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2016] [Revised: 07/31/2016] [Accepted: 08/01/2016] [Indexed: 11/17/2022]
Abstract
Purpose. To compare the ocular surface symptoms and signs in an adult population of silicone-hydrogel (Si-Hy) contact lens (CL) wearers with another modality of CL wear, overnight orthokeratology (OK). Materials and Methods. This was a prospective and comparative study in which 31 myopic subjects were fitted with the same Si-Hy CL and 23 underwent OK treatment for 3 months. Dry eye questionnaire (DEQ) was filled in at the beginning of the study and then after 15 days, 1 month, and 3 months using each CL modality. The tear quality was evaluated with noninvasive tear break-up time. Tear production was measured with Schirmer test. Tear samples were collected with Schirmer strips being frozen to analyze the dinucleotide diadenosine tetraphosphate (Ap4A) concentration with High-Performance Liquid Chromatography (HPLC). Results. After refitting with ortho-k, a reduction in discomfort and dryness symptoms at the end of the day (p < 0.05, χ2) was observed. No significant changes were observed in Ap4A concentration in any group. Bulbar redness, limbal redness, and conjunctival staining increased significantly in the Si-Hy group (p < 0.05, Kruskal-Wallis test). Conclusion. Discomfort and dryness symptoms at the end of the day are lower in the OK CL group than in the Si-Hy CL group.
Collapse
|
25
|
Efron N, Brennan NA, Morgan PB, Wilson T. Lid wiper epitheliopathy. Prog Retin Eye Res 2016; 53:140-174. [PMID: 27094372 DOI: 10.1016/j.preteyeres.2016.04.004] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 04/05/2016] [Accepted: 04/12/2016] [Indexed: 01/12/2023]
Abstract
Some recent research has resulted in a hypothesis that there is a common 'lid wiper' region that is apposite to the ocular surface or anterior lens surface (where contact lenses are worn), responsible for spreading tears during blinking. In the upper eyelid, it extends about 0.6 mm from the crest of the sharp posterior (inner) lid border (i.e. the mucocutaneous junction, or line of Marx) to the subtarsal fold superiorly and from the medial upper punctum to the lateral canthus horizontally. Histologically, it is seen as an epithelial elevation comprising of stratified epithelium with a transitional conjunctival structure of (moving posteriorly) squamous cells then cuboidal cells, with some parakeratinised cells and goblet cells. Lid wiper epitheliopathy (LWE) denotes staining of the lid wiper observed after instillation of dyes such as fluorescein, rose bengal or lissamine green. There have been some reports of higher rates of LWE in dry eye patients and contact lens wearers, but others have failed to find such associations. The primary cause of LWE is thought to be increased friction between the lid wiper and ocular or anterior contact lens surface due to inadequate lubrication, which could be caused by dry eye and may be exacerbated by factors such as abnormal blinking patterns, poor contact lens surface lubricity and adverse environmental influences. Recent evidence suggests that LWE is associated with sub-clinical inflammation. LWE has the potential to provide the missing mechanistic link between clinical observation and symptoms associated with dry eye and contact lens wear. Clinical and fundamental research into LWE is still in its infancy and in many instances equivocal; however, it is an idea that provides a potentially important new avenue for further investigation of anterior eye discomfort associated with ocular dryness and contact lens wear.
Collapse
Affiliation(s)
- Nathan Efron
- Institute of Health and Biomedical Innovation, School of Optometry and Vision Science, Queensland University of Technology, 60 Musk Avenue, Kelvin Grove, Queensland 4059, Australia.
| | - Noel A Brennan
- Johnson & Johnson Vision Care, Inc., 7500 Centurion Parkway, Jacksonville, FL 32256, USA
| | - Philip B Morgan
- Eurolens Research, The University of Manchester, Dover Street, Manchester, M13 9PL, UK
| | - Tawnya Wilson
- Johnson & Johnson Vision Care, Inc., 7500 Centurion Parkway, Jacksonville, FL 32256, USA
| |
Collapse
|
26
|
|
27
|
Contact Lens Discomfort and Dropout. What is it? Epidemiology. CURRENT OPHTHALMOLOGY REPORTS 2015. [DOI: 10.1007/s40135-015-0068-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
28
|
Stapleton F, Golebiowski B, Skotnitsky C, Tan ME, Holden BA. Corneal and conjunctival sensitivity in intolerant contact lens wearers. JOURNAL OF OPTOMETRY 2015; 8:62-63. [PMID: 25649641 PMCID: PMC4314623 DOI: 10.1016/j.optom.2014.05.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2014] [Revised: 04/28/2014] [Accepted: 04/28/2014] [Indexed: 06/04/2023]
Affiliation(s)
- Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia; Vision CRC, Sydney, Australia; Brien Holden Vision Institute, University of New South Wales, Sydney, Australia
| | - Blanka Golebiowski
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia; Vision CRC, Sydney, Australia.
| | - Cheryl Skotnitsky
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia; Vision CRC, Sydney, Australia
| | - Maxine E Tan
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia; Vision CRC, Sydney, Australia; The Queensland Lung Transplant Service, The Prince Charles Hospital, Brisbane, Australia
| | - Brien A Holden
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia; Vision CRC, Sydney, Australia; Brien Holden Vision Institute, University of New South Wales, Sydney, Australia
| |
Collapse
|
29
|
Stapleton F, Marfurt C, Golebiowski B, Rosenblatt M, Bereiter D, Begley C, Dartt D, Gallar J, Belmonte C, Hamrah P, Willcox M. The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on neurobiology. Invest Ophthalmol Vis Sci 2013; 54:TFOS71-97. [PMID: 24058137 PMCID: PMC5963174 DOI: 10.1167/iovs.13-13226] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2013] [Accepted: 09/10/2013] [Indexed: 12/26/2022] Open
Abstract
This report characterizes the neurobiology of the ocular surface and highlights relevant mechanisms that may underpin contact lens-related discomfort. While there is limited evidence for the mechanisms involved in contact lens-related discomfort, neurobiological mechanisms in dry eye disease, the inflammatory pathway, the effect of hyperosmolarity on ocular surface nociceptors, and subsequent sensory processing of ocular pain and discomfort have been at least partly elucidated and are presented herein to provide insight in this new arena. The stimulus to the ocular surface from a contact lens is likely to be complex and multifactorial, including components of osmolarity, solution effects, desiccation, thermal effects, inflammation, friction, and mechanical stimulation. Sensory input will arise from stimulation of the lid margin, palpebral and bulbar conjunctiva, and the cornea.
Collapse
Affiliation(s)
- Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Carl Marfurt
- Indiana University School of Medicine–Northwest, Gary, Indiana
| | - Blanka Golebiowski
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Mark Rosenblatt
- Weill Cornell Medical College, Cornell University, Ithaca, New York
| | - David Bereiter
- University of Minnesota School of Dentistry, Minneapolis, Minnesota
| | - Carolyn Begley
- Indiana University School of Optometry, Bloomington, Indiana
| | - Darlene Dartt
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Juana Gallar
- Instituto de Neurociencias de Alicante, Universidad Miguel Hernandez–Consejo Superior de Investigaciones Cientificas, Alicante, Spain
| | - Carlos Belmonte
- Instituto de Neurociencias de Alicante, Universidad Miguel Hernandez–Consejo Superior de Investigaciones Cientificas, Alicante, Spain
| | - Pedram Hamrah
- Massachusetts Eye and Ear Infirmary, Stoneham, Massachusetts
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | | |
Collapse
|