1
|
Strok A, Dolenc Novak M, Guzic Salobir B, Stalc M, Zaletel K. The Effect of Monitored Walking on Extracardiac Intestinal Activity in Myocardial Perfusion Imaging. J Nucl Med Technol 2024; 52:331-336. [PMID: 39288972 DOI: 10.2967/jnmt.124.267917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 08/28/2024] [Indexed: 09/19/2024] Open
Abstract
Various techniques have been used in attempts to reduce interfering gastrointestinal activity in myocardial perfusion imaging (MPI); however, these approaches have yielded inconsistent results. The goal of this study was to investigate the efficacy of monitored walking, a previously unexplored technique, in reducing subdiaphragmatic activity-related artifacts during pharmacologic stress 99mTc-tetrofosmin MPI with SPECT to improve the overall image quality. Methods: The study included patients who underwent MPI with pharmacologic stress. They were given a step counter immediately after the radiotracer injection and were randomized into a group A, with a request to walk at least 1,000 steps before imaging, and a group B, with no specific instructions about walking. The reconstructed SPECT images were assessed visually. Moderate and severe levels of subdiaphragmatic tracer activity were considered relevant for the interpretation of the scans. Additionally, myocardial and abdominal activity was semiquantitatively assessed on raw planar images, and the mean myocardium-to-abdomen count ratios were calculated. Results: We enrolled 199 patients (95 patients in group A and 104 patients in group B). Clinical characteristics did not differ significantly between the 2 groups. Patients in group A walked more steps than patients in group B (P < 0.001), but there were no differences in the proportion of accepted scans between the 2 groups (P = 0.41). Additionally, there were no differences in the proportion of relevant subdiaphragmatic activity between the groups (P = 0.91). The number of steps did not impact the acceptance rate (P = 0.29). Conclusion: A higher number of steps walked during the waiting period between pharmacologic stress and acquisition does not affect subdiaphragmatic activity-related artifacts or the proportion of accepted scans after pharmacologic stress. However, pedometer use and clear instructions motivate patients to walk while awaiting imaging. Larger studies are required to compare a higher-step-count group with a sedentary control group to assess the influence of walking on gastrointestinal artifacts in MPI.
Collapse
Affiliation(s)
- Anja Strok
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia; and
| | - Maja Dolenc Novak
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia; and
| | - Barbara Guzic Salobir
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia; and
| | - Monika Stalc
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia; and
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Katja Zaletel
- Department of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia; and
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
2
|
Strok A, Salobir BG, Stalc M, Zaletel K. Subdiaphragmatic activity-related artifacts in myocardial perfusion scintigraphy. Radiol Oncol 2024; 58:313-319. [PMID: 39287166 PMCID: PMC11406902 DOI: 10.2478/raon-2024-0053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2024] [Accepted: 06/21/2024] [Indexed: 09/19/2024] Open
Abstract
BACKGROUND Myocardial perfusion imaging (MPI) with single photon emission computed tomography is an established non-invasive technique for assessing myocardial ischemia. This method involves the intravenous administration of a radiopharmaceutical that accumulates in the heart muscle proportional to regional blood flow. However, image quality and diagnostic accuracy can be compromised by various technical and patient-related factors, including high non-specific radiopharmaceutical uptake in abdominal organs such as the stomach, intestines, liver, and gall-bladder, leading to subdiaphragmatic artifacts. These artifacts are particularly problematic for evaluating inferior wall perfusion and often necessitate repeated imaging, which decreases gamma camera availability and prolongs imaging times. CONCLUSIONS Despite numerous investigated techniques to reduce interfering gastrointestinal activity, results have been inconsistent, and current MPI guidelines provide scant information on effective procedures to mitigate this issue. Based on our experience, some possible approaches to reducing artifacts include choosing stress testing with an exercise stress test, when possible, late imaging, fluid intake, and consuming carbonated water immediately before imaging.
Collapse
Affiliation(s)
- Anja Strok
- Division of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia
| | - Barbara Guzic Salobir
- Division of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia
| | - Monika Stalc
- Division of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Katja Zaletel
- Division of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
3
|
Case JA, Courter SA, McGhie AI, Patel KK, Sperry BW, Moloney E, Case KO, Burgett EV, Bateman TM. Accurate and efficient rapid acquisition early post-injection stress-first CZT SPECT myocardial perfusion imaging with tetrofosmin and attenuation correction. J Nucl Cardiol 2023; 30:2644-2654. [PMID: 37464251 DOI: 10.1007/s12350-023-03336-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 06/01/2023] [Indexed: 07/20/2023]
Abstract
INTRODUCTION Myocardial perfusion imaging (MPI) protocols have not changed significantly despite advances in instrumentation and software. We compared an early post-injection, stress-first SPECT protocol to standard delayed imaging. METHODS 95 patients referred for SPECT MPI were imaged upright and supine on a Spectrum Dynamics D-SPECT CZT system with CT attenuation correction. Patients received injection of 99mTc tetrofosmin at peak of regadenoson stress and were imaged. Early post-stress (mean 17 ± 2 minutes) and Standard 1-h delay (mean 61 ± 13 min). Three blinded readers evaluated images for overall interpretation, perceived need for rest imaging, image quality, and reader confidence. Laboratory efficiency was also evaluated. RESULTS Blinded readers had the same response for the need for rest in 77.9% of studies. Studies also had the same interpretation in 89.5% of studies. Reader confidence was high (86.0% (Early) and 90.3% (Standard p = 0.52. Image quality was good or excellent in 87.4% Early vs 96.8% Standard (p = 0.09). Time between patient check-in and end of stress imaging was 104 ± (Standard) to 60 ± 18 minutes (Early) (p < 0.001). CONCLUSION Early post-injection stress-only imaging using CZT SPECT/CT appears promising with Tc-99m tetrofosmin with similar image quality, reader confidence, diagnosis, and need for a rest scan.
Collapse
Affiliation(s)
- James A Case
- Cardiovascular Imaging Technologies, Kansas City, MO, USA.
| | | | - AIain McGhie
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Krishna K Patel
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
- Icahn School of Medicine at Mount Sinai Medical Center, New York, New York, USA
| | - Brett W Sperry
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Erin Moloney
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Katrina O Case
- Cardiovascular Imaging Technologies, Kansas City, MO, USA
- Boston University, Boston, MA, USA
| | - Eric V Burgett
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Timothy M Bateman
- Cardiovascular Imaging Technologies, Kansas City, MO, USA
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| |
Collapse
|
4
|
Duvall WL, Case J, Lundbye J, Cerqueira M. Efficiency of tetrofosmin versus sestamibi achieved through shorter injection-to-imaging times: A systematic review of the literature. J Nucl Cardiol 2021; 28:1381-1394. [PMID: 32236839 PMCID: PMC8421307 DOI: 10.1007/s12350-020-02093-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 02/19/2020] [Indexed: 11/20/2022]
Abstract
Based on superior image quality, more accurate gated images, and lower radiation exposure to patients, Technetium-99m (Tc-99m) based tracers are preferred over Thallium-201 for SPECT myocardial perfusion imaging. The two Tc-99m tracers, sestamibi and tetrofosmin, have many similar characteristics but there are differences in blood and liver clearance rates, as well as the recommended time after injection for imaging to achieve optimal image quality. Because published peer-reviewed studies examining optimal times between injection and imaging are limited, it can be difficult to identify evidence-based opportunities to optimize imaging protocols. Using systematic literature review methods, this study was designed to identify and consolidate the available evidence on the use of sestamibi compared to tetrofosmin for variable injection to imaging times in regard to test efficiency, including test length and re-scan rates, and image quality, including overall quality and cardiac to extra-cardiac ratios. The composite of this data shows that earlier imaging with tetrofosmin is equivalent to later imaging with sestamibi when assessing subjective image quality or when quantifying heart-to-extra-cardiac ratios. Image quality and heart-to-extra-cardiac ratios comparing early versus later imaging with tetrofosmin were comparable if not equivalent to each other. The equivalency of the imaging quality occurs with 15 minutes (on average) earlier imaging compared to sestamibi and 30 minutes compared to standard time tetrofosmin. The subjective findings of equivalent image quality are also shown with objective measurements of heart-to-extra-cardiac ratios. In this review, the significantly shorter injection-to-acquisition times with tetrofosmin compared to sestamibi resulted in better efficiency and less waiting times for patients; in addition, significantly higher re-scan rates with sestamibi compared to tetrofosmin due to hepatic activity contributed to better throughput with tetrofosmin.
Collapse
Affiliation(s)
- W Lane Duvall
- Hartford Hospital, Heart and Vascular Institute, 80 Seymour Street, Hartford, CT, 06102, USA.
| | - James Case
- Cardiovascular Imaging Technologies, Kansas City, MO, USA
| | - Justin Lundbye
- The Greater Waterbury Health Network, Waterbury, CT, USA
| | - Manuel Cerqueira
- Department of Nuclear Medicine, Department of Cardiovascular Imaging, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
5
|
A randomized-controlled study of a modified technique to reduce extracardiac activity in myocardial perfusion imaging. Nucl Med Commun 2017; 38:21-28. [DOI: 10.1097/mnm.0000000000000600] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
6
|
Comparison between a count-based and geometrical approach for the assessment of left ventricular dyssynchrony using myocardial perfusion scintigraphy. Nucl Med Commun 2016; 37:1125-35. [PMID: 27383191 DOI: 10.1097/mnm.0000000000000574] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE There are two distinct approaches for the assessment of left ventricular (LV) dyssynchrony by myocardial perfusion scintigraphy (MPS). The aim of this study was to compare the performance of the count-based and geometrical approach in clinical data using gated single photon emission computed tomography MPS. MATERIAL AND METHODS Group 1 consisted of 113 patients (49 men, 64 women) with normal perfusion [summed rest score (SRS)≤3], normal LV ejection fraction (≥55%), and normal QRS duration (QRSd<120 ms). Group 2 consisted of 89 heart failure patients (79 men, 10 women) with no restriction for SRS, LV ejection fraction ≤35%, and QRSd ≥120 ms. All MPS parameters were obtained from the software Corridor4DM. Dyssynchrony parameters used were time to peak contraction, SD, and bandwidth (BW). RESULTS SD and BW were estimated higher (difference group 1: SD 3.0±2.3 and BW 11.3±9.3, P-values <0.001; difference group 2: SD 2.4±4.3 and BW 1.3±17.0, P-value <0.001 and 0.479 respectively) using the count-based approach in comparison with the geometrical method. A significant and good correlation was found between these two methods (R=0.763, 0.902, 0.896 for time to peak contraction, SD, and BW respectively, P-values ≤0.001). SD and BW in both approaches were equally good parameters for differentiating heart failure patients (area under the curve: 0.995-0.998), although using different cut-off values. CONCLUSION The count-based approach generally provides a wider phase distribution and subsequently greater SD and BW estimates compared with the geometrical algorithm. These differences result in clinically relevant deviations in normal and cut-off values that have to be recognized when evaluating patients.
Collapse
|
7
|
Early gated SPECT adenosine myocardial perfusion imaging may influence the therapeutic management of patients with coronary artery disease. Nucl Med Commun 2015; 36:386-91. [PMID: 25569866 DOI: 10.1097/mnm.0000000000000258] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
AIM The aim of the study was to investigate whether myocardial perfusion imaging at 15 min after injection (T15) is more accurate in detecting coronary artery disease than that at 45 min (T45). PATIENTS AND METHODS Two-day stress/rest 99mTc-tetrofosmin gated SPECT was performed at T15 and T45 in 50 patients. Coronary angiography was considered when poststress and resting images were discordant. Tracer washout rates were calculated for the myocardium, liver, and subdiaphragmatic region. Perfusion sum difference scores were derived using QPS software. RESULTS T15 and T45 were discordant in 18/50 (36%) patients. In 16/18 patients (89%) discordant deficits were more apparent at T15. A total of 13/16 patients underwent coronary angiography, of whom 12 had coronary artery disease. Poststress, but not resting, left ventricular ejection fraction was lower at T15 (P=0.02). Sum difference scores were higher at T15 [2.2 (1.9)] than at T45 [1.6 (1.7); P<0.05]. Tracer washout rates from the liver [46 (13.3)%] and subdiaphragmatic region [36 (21.3)%] were significant (P<0.0001), but there was no change in myocardial activity. CONCLUSION T15 detected more abnormalities than did T45. The reduction in left ventricular ejection fraction after stress may result from adenosine-induced poststunning at T15. Accordingly, the T15 protocol may be useful in the assessment of hibernating myocardium. Contrasting myocardial and hepatic washout rates may be attributable to differential ABC transporter expression.
Collapse
|
8
|
Pirich C, Keinrath P, Rettenbacher L, Rendl G, Holzmannhofer J, Hammerer M, Schuler J, Beheshti M. 99mTc tetrofosmin myocardial perfusion scintigraphy in CAD. Performance with early and standard delayed acquisition and fractional flow reserve. Nuklearmedizin 2014; 53:111-6. [PMID: 24963973 DOI: 10.3413/nukmed-0617-13-08] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Accepted: 10/02/2013] [Indexed: 11/20/2022]
Abstract
AIM Early stress imaging (15 min after injection of the radiopharmaceutical) in 99mTc tetrofosmin myocardial perfusion scintigraphy (MPS) has been shown feasible in comparison to standard imaging after 45 minutes, but the effects on image quality and diagnostic accuracy ask for further evaluation. PATIENTS, METHODS 97 patients (61 men, 36 women, age 69 ± 11 years) underwent both early (EA) and standard (SA) acquisition (after 14 ± 4 min and 43 ± 6 min, respectively) using 99mTc tetrofosmin gated SPECT with iterative reconstruction. Sub-diaphragmatic tracer activity and image quality was scored in a 4-point scale by blinded observers. Semiquantitative myocardial perfusion analysis was performed on a 17-segment model using standard cardiac quantification SPECT software (4 DM-SPECT). Stenoses of indeterminate haemodynamic significance were validated by measurement of fractional flow reserve (FFR). RESULTS Extra-cardiac tracer activity was more commonly found in EA (43%) than in SA (38%), but without any diagnostic impact in > 95% of the patients. The mean summed stress score was significantly higher for early than standard imaging (6.4 ± 6.3 vs. 5.6 ± 6.1, p = 0.009). The amount of ischaemic area was not significantly different (EA: 9.1 ± 6.7 % vs. SA: 7.8 ± 6.9 %). The mean stress ejection fraction was 52 ± 11% (EA) compared to 55 ± 11 % (SA) (p = ns). FFR was inversely related to SDS at early (r = -0.704, p < 0.05) and standard (r = -0.678, p < 0.05) acquisition. All patients with a FFR < 0.8 (considered as hemodynamically significant stenoses) revealed a positive scan. CONCLUSION Stress 99mTc tetrofosmin MPS with early acquisition is feasible and at least equally accurate when iterative reconstruction is applied.
Collapse
Affiliation(s)
- C Pirich
- Prof. Dr. Christian Pirich, Department of Nuclear Medicine and Endocrinology, University Hospital Salzburg,, Muellner Hauptstrasse 48, 5020 Salzburg, Austria, Tel.+43/662/44 82 35 00, Fax +43/662/44 82 35 11, E-mail:
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Diagnostic and Prognostic Value of Gated SPECT MIBI Early Post-Stress Imaging in Patients With Intermediate Duke Treadmill Score. Clin Nucl Med 2013; 38:784-9. [DOI: 10.1097/rlu.0b013e31829f8e5a] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|