1
|
Darwish OI, Koch V, Vogl TJ, Wolf M, Schregel K, Purushotham A, Vilgrain V, Paradis V, Neji R, Sinkus R. MR Elastography Using the Gravitational Transducer. SENSORS (BASEL, SWITZERLAND) 2024; 24:8038. [PMID: 39771774 PMCID: PMC11679839 DOI: 10.3390/s24248038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2024] [Revised: 12/02/2024] [Accepted: 12/12/2024] [Indexed: 01/11/2025]
Abstract
MR elastography is a non-invasive imaging technique that provides quantitative maps of tissue biomechanical properties, i.e., elasticity and viscosity. Currently, hepatic MR elastography is deployed in the clinic to assess liver fibrosis in MAFLD patients. In addition, research has demonstrated MR elastography's ability to non-invasively assess chronic liver disease and to characterize breast cancer lesions and brain tumors. MR elastography requires efficient mechanical wave generation and penetration, motion-sensitized MRI sequences, and MR elastography inversion algorithms to retrieve the biomechanical properties of the tissue. MR elastography promises to enable non-invasive and versatile assessment of tissue, leading to better diagnosis and staging of several clinical conditions.
Collapse
Affiliation(s)
- Omar Isam Darwish
- Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, London WC2R 2LS, UK; (R.N.)
- MR Predevelopment, Siemens Healthineers, 91052 Erlangen, Germany
| | - Vitali Koch
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60629 Frankfurt am Main, Germany
| | - Thomas J. Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60629 Frankfurt am Main, Germany
| | - Marcos Wolf
- Centre for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Austria
| | - Katharina Schregel
- Department of Neuroradiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Arnie Purushotham
- School of Cancer & Pharmaceutical Sciences, King’s College London, London WC2R 2LS, UK
| | - Valérie Vilgrain
- INSERM, Centre de Recherche sur l’Inflammation, Universite Paris Cite, 45018 Paris, France
- Department of Radiology, Hospital Beaujon, 92110 Clichy, France
| | - Valérie Paradis
- INSERM, Centre de Recherche sur l’Inflammation, Universite Paris Cite, 45018 Paris, France
- Department of Pathology, Hospital Beaujon, 92110 Clichy, France
| | - Radhouene Neji
- Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, London WC2R 2LS, UK; (R.N.)
| | - Ralph Sinkus
- Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King’s College London, London WC2R 2LS, UK; (R.N.)
- Laboratory for Vascular Translational Science (LVTS), INSERM U1148, 75877 Paris, France
| |
Collapse
|
2
|
Meyer T, Castelein J, Schattenfroh J, Sophie Morr A, Vieira da Silva R, Tzschätzsch H, Reiter R, Guo J, Sack I. Magnetic resonance elastography in a nutshell: Tomographic imaging of soft tissue viscoelasticity for detecting and staging disease with a focus on inflammation. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2024; 144-145:1-14. [PMID: 39645347 DOI: 10.1016/j.pnmrs.2024.05.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 05/24/2024] [Accepted: 05/27/2024] [Indexed: 12/09/2024]
Abstract
Magnetic resonance elastography (MRE) is an emerging clinical imaging modality for characterizing the viscoelastic properties of soft biological tissues. MRE shows great promise in the noninvasive diagnosis of various diseases, especially those associated with soft tissue changes involving the extracellular matrix, cell density, or fluid turnover including altered blood perfusion - all hallmarks of inflammation from early events to cancer development. This review covers the fundamental principles of measuring tissue viscoelasticity by MRE, which are based on the stimulation and encoding of shear waves and their conversion into parameter maps of mechanical properties by inverse problem solutions of the wave equation. Technical challenges posed by real-world biological tissue properties such as viscosity, heterogeneity, anisotropy, and nonlinear elastic behavior of tissues are discussed. Applications of MRE measurement in both humans and animal models are presented, with emphasis on the detection, characterization, and staging of diseases related to the cascade of biomechanical property changes from early to chronic inflammation in the liver and brain. Overall, MRE provides valuable insights into the biophysics of soft tissues for imaging-based detection and staging of inflammation-associated tissue changes.
Collapse
Affiliation(s)
- Tom Meyer
- Department of Radiology, Charité - Universitätsmedizin Berlin, Germany
| | - Johannes Castelein
- Department of Radiology & Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, Netherlands; Department for Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | | | - Anna Sophie Morr
- Department of Radiology, Charité - Universitätsmedizin Berlin, Germany
| | - Rafaela Vieira da Silva
- Experimental and Clinical Research Center, a cooperation between the Max Delbrück Center for Molecular Medicine in the Helmholtz Association and Charité - Universitätsmedizin Berlin, Germany
| | - Heiko Tzschätzsch
- Institute of Medical Informatics, Charité - Universitätsmedizin Berlin, Germany
| | - Rolf Reiter
- Department of Radiology, Charité - Universitätsmedizin Berlin, Germany
| | - Jing Guo
- Department of Radiology, Charité - Universitätsmedizin Berlin, Germany
| | - Ingolf Sack
- Department of Radiology, Charité - Universitätsmedizin Berlin, Germany.
| |
Collapse
|
3
|
Engelke K, Chaudry O, Gast L, Eldib MAB, Wang L, Laredo JD, Schett G, Nagel AM. Magnetic resonance imaging techniques for the quantitative analysis of skeletal muscle: State of the art. J Orthop Translat 2023; 42:57-72. [PMID: 37654433 PMCID: PMC10465967 DOI: 10.1016/j.jot.2023.07.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 07/04/2023] [Accepted: 07/19/2023] [Indexed: 09/02/2023] Open
Abstract
Background Magnetic resonance imaging (MRI) is the dominant 3D imaging modality to quantify muscle properties in skeletal muscle disorders, in inherited and acquired muscle diseases, and in sarcopenia, in cachexia and frailty. Methods This review covers T1 weighted and Dixon sequences, introduces T2 mapping, diffusion tensor imaging (DTI) and non-proton MRI. Technical concepts, strengths, limitations and translational aspects of these techniques are discussed in detail. Examples of clinical applications are outlined. For comparison 31P-and 13C-MR Spectroscopy are also addressed. Results MRI technology provides a rich toolset to assess muscle deterioration. In addition to classical measures such as muscle atrophy using T1 weighted imaging and fat infiltration using Dixon sequences, parameters characterizing inflammation from T2 maps, tissue sodium using non-proton MRI techniques or concentration or fiber architecture using diffusion tensor imaging may be useful for an even earlier diagnosis of the impairment of muscle quality. Conclusion Quantitative MRI provides new options for muscle research and clinical applications. Current limitations that also impair its more widespread use in clinical trials are lack of standardization, ambiguity of image segmentation and analysis approaches, a multitude of outcome parameters without a clear strategy which ones to use and the lack of normal data.
Collapse
Affiliation(s)
- Klaus Engelke
- Department of Medicine III, Friedrich-Alexander University of Erlangen-Nürnberg, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
- Institute of Medical Physics (IMP), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Henkestr. 91, 91052, Erlangen, Germany
- Clario Inc, Germany
| | - Oliver Chaudry
- Department of Medicine III, Friedrich-Alexander University of Erlangen-Nürnberg, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
| | - Lena Gast
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | | | - Ling Wang
- Department of Radiology, Beijing Jishuitan Hospital, Beijing, China
| | - Jean-Denis Laredo
- Service d’Imagerie Médicale, Institut Mutualiste Montsouris & B3OA, UMR CNRS 7052, Inserm U1271 Université de Paris-Cité, Paris, France
| | - Georg Schett
- Department of Medicine III, Friedrich-Alexander University of Erlangen-Nürnberg, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
| | - Armin M. Nagel
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| |
Collapse
|
4
|
Tavakoli J, Geargeflia S, Tipper JL, Diwan AD. Magnetic resonance elastography: A non-invasive biomarker for low back pain studies. BIOMEDICAL ENGINEERING ADVANCES 2021. [DOI: 10.1016/j.bea.2021.100014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
5
|
Qiu S, He Z, Wang R, Li R, Zhang A, Yan F, Feng Y. An electromagnetic actuator for brain magnetic resonance elastography with high frequency accuracy. NMR IN BIOMEDICINE 2021; 34:e4592. [PMID: 34291510 DOI: 10.1002/nbm.4592] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Revised: 06/07/2021] [Accepted: 07/06/2021] [Indexed: 06/13/2023]
Abstract
Our goal is to design, test and verify an electromagnetic actuator for brain magnetic resonance elastography (MRE). We proposed a grappler-shaped design that can transmit stable vibrations into the brain. To validate its performance, simulations were carried out to ensure the electromagnetic field generated by the actuator did not interfere with the B0 field. The actuation vibration spectrum was analyzed to verify the actuation accuracy. Phantom and volunteer experiments were carried out to evaluate the performance of the actuator. Simulation of the magnetic field showed that the proposed actuator has a fringe field of less than 3 G in the imaging region. The phantom experiments showed that the proposed actuator did not interfere with the routine imaging sequences. The measured vibration spectra demonstrated that the frequency offset was about one third that of a pneumatic device and the transmission efficiency was three times higher. The shear moduli estimated from brain MRE were consistent with those from the literature. The actuation frequency of the proposed actuator has less frequency offset and off-center frequency components compared with the pneumatic counterpart. The whole actuator weighted only 980 g. The actuator can carry out multifrequency MRE on the brain with high accuracy. It is easy to use, comfortable for the patient and portable.
Collapse
Affiliation(s)
- Suhao Qiu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhao He
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Runke Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Ruokun Li
- Department of Radiology, Ruijin Hospital, Shanghai, China
| | - Aili Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital, Shanghai, China
| | - Yuan Feng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
6
|
Usumura M, Kishimoto R, Ishii K, Hotta E, Kershaw J, Higashi T, Obata T, Suga M. Longitudinal stability of a multimodal visco-elastic polyacrylamide gel phantom for magnetic resonance and ultrasound shear-wave elastography. PLoS One 2021; 16:e0250667. [PMID: 34019551 PMCID: PMC8139483 DOI: 10.1371/journal.pone.0250667] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 04/08/2021] [Indexed: 11/22/2022] Open
Abstract
We evaluated the long-term stability of a newly developed viscoelastic phantom made of polyacrylamide (PAAm) gel for magnetic resonance elastography (MRE) and ultrasound-based shear-wave elastography (US SWE). The stiffness of the cylindrical phantom was measured at 0, 13 and 18 months. Storage and loss moduli were measured with MRE, and shear-wave speed (SWS) was measured with US SWE. Long-term stability was evaluated in accordance with the Quantitative Imaging Biomarker Alliance (QIBA) profiles for each modality. The initial storage and loss moduli of the phantom were 5.01±0.22 and 1.11±0.15 respectively, and SWS was 2.57±0.04 m/s. The weight of the phantom decreased by 0.6% over the 18 months. When measured with MRE, the stiffness of the phantom decreased and changes to the storage and loss moduli were -3.0% and -4.6% between 0 and 13 months, and -4.3% and 0.0% between 0 and 18 months. The US measurements found that SWS decreased by 2.4% over the first 13 months and 3.6% at 18 months. These changes were smaller than the tolerances specified in the QIBA profiles, so the viscoelastic PAAm gel phantom fulfilled the condition for long-term stability. This new phantom has the potential to be used as a quality assurance and quality control phantom for MRE and US SWE.
Collapse
Affiliation(s)
- Masashi Usumura
- Department of Medical Engineering, Graduate School of Science and Engineering, Chiba University, Chiba, Japan
| | - Riwa Kishimoto
- QST Hospital, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Koki Ishii
- Department of Medical Engineering, Graduate School of Science and Engineering, Chiba University, Chiba, Japan
| | - Eika Hotta
- QST Hospital, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Jeff Kershaw
- Applied MRI Research, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Tatsuya Higashi
- Department of Molecular Imaging and Theranostics, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Takayuki Obata
- Applied MRI Research, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Mikio Suga
- Center for Frontier Medical Engineering, Chiba University, Chiba, Japan
| |
Collapse
|
7
|
Arani A, Manduca A, Ehman RL, Huston Iii J. Harnessing brain waves: a review of brain magnetic resonance elastography for clinicians and scientists entering the field. Br J Radiol 2021; 94:20200265. [PMID: 33605783 PMCID: PMC8011257 DOI: 10.1259/bjr.20200265] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
Brain magnetic resonance elastography (MRE) is an imaging technique capable of accurately and non-invasively measuring the mechanical properties of the living human brain. Recent studies have shown that MRE has potential to provide clinically useful information in patients with intracranial tumors, demyelinating disease, neurodegenerative disease, elevated intracranial pressure, and altered functional states. The objectives of this review are: (1) to give a general overview of the types of measurements that have been obtained with brain MRE in patient populations, (2) to survey the tools currently being used to make these measurements possible, and (3) to highlight brain MRE-based quantitative biomarkers that have the highest potential of being adopted into clinical use within the next 5 to 10 years. The specifics of MRE methodology strategies are described, from wave generation to material parameter estimations. The potential clinical role of MRE for characterizing and planning surgical resection of intracranial tumors and assessing diffuse changes in brain stiffness resulting from diffuse neurological diseases and altered intracranial pressure are described. In addition, the emerging technique of functional MRE, the role of artificial intelligence in MRE, and promising applications of MRE in general neuroscience research are presented.
Collapse
Affiliation(s)
- Arvin Arani
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Armando Manduca
- Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | | | | |
Collapse
|
8
|
Malattia C, Tolend M, Mazzoni M, Panwar J, Zlotnik M, Otobo T, Vidarsson L, Doria AS. Current status of MR imaging of juvenile idiopathic arthritis. Best Pract Res Clin Rheumatol 2020; 34:101629. [PMID: 33281052 DOI: 10.1016/j.berh.2020.101629] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Juvenile idiopathic arthritis (JIA) is the most common chronic arthropathy in the pediatric population. Although the diagnosis is essentially clinical for many affected joints, MR imaging has become an important tool for the assessment of joints that are difficult to evaluate clinically, such as temporomandibular and sacroiliac joints, and for screening of inflammatory changes in the entire body by whole body MRI (WBMRI) assessment. The utilization of MR imaging is challenging in the pediatric population given the need for discrimination between pathological and physiological changes in the growing skeleton. Several multicentric multidisciplinary organizations have made major efforts over the past decades to standardize, quantify, and validate scoring systems to measure joint changes both cross-sectionally and longitudinally according to rigorous methodological standards. In this paper, we (1) discuss current trends for the diagnosis and management of JIA, (2) review challenges for detecting real pathological changes in growing joints, (3) summarize the current status of standardization of MRI protocols for data acquisition and the quantification of joint pathology in JIA by means of scoring systems, and (4) outline novel MR imaging techniques for the evaluation of anatomy and function of joints in JIA. Optimizing the role of MRI as a robust biomarker and outcome measure remains a priority of future research in this field.
Collapse
Affiliation(s)
- Clara Malattia
- Clinica Pediatrica e Reumatologia, Istituto Giannina Gaslini, Genoa, Italy; Department of Neurosciences, Rehabilitation, Ophthalmology, Genetic and Maternal Infantile Sciences (DINOGMI), University of Genoa, Italy
| | - Mirkamal Tolend
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
| | - Marta Mazzoni
- Clinica Pediatrica e Reumatologia, Istituto Giannina Gaslini, Genoa, Italy; Department of Neurosciences, Rehabilitation, Ophthalmology, Genetic and Maternal Infantile Sciences (DINOGMI), University of Genoa, Italy
| | - Jyoti Panwar
- Department of Radiology, Christian Medical College, Vellore, India
| | - Margalit Zlotnik
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
| | - Tarimobo Otobo
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
| | - Logi Vidarsson
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
| | - Andrea S Doria
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada; Department of Medical Imaging, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|
9
|
Strijkers GJ, Araujo EC, Azzabou N, Bendahan D, Blamire A, Burakiewicz J, Carlier PG, Damon B, Deligianni X, Froeling M, Heerschap A, Hollingsworth KG, Hooijmans MT, Karampinos DC, Loudos G, Madelin G, Marty B, Nagel AM, Nederveen AJ, Nelissen JL, Santini F, Scheidegger O, Schick F, Sinclair C, Sinkus R, de Sousa PL, Straub V, Walter G, Kan HE. Exploration of New Contrasts, Targets, and MR Imaging and Spectroscopy Techniques for Neuromuscular Disease - A Workshop Report of Working Group 3 of the Biomedicine and Molecular Biosciences COST Action BM1304 MYO-MRI. J Neuromuscul Dis 2020; 6:1-30. [PMID: 30714967 PMCID: PMC6398566 DOI: 10.3233/jnd-180333] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Neuromuscular diseases are characterized by progressive muscle degeneration and muscle weakness resulting in functional disabilities. While each of these diseases is individually rare, they are common as a group, and a large majority lacks effective treatment with fully market approved drugs. Magnetic resonance imaging and spectroscopy techniques (MRI and MRS) are showing increasing promise as an outcome measure in clinical trials for these diseases. In 2013, the European Union funded the COST (co-operation in science and technology) action BM1304 called MYO-MRI (www.myo-mri.eu), with the overall aim to advance novel MRI and MRS techniques for both diagnosis and quantitative monitoring of neuromuscular diseases through sharing of expertise and data, joint development of protocols, opportunities for young researchers and creation of an online atlas of muscle MRI and MRS. In this report, the topics that were discussed in the framework of working group 3, which had the objective to: Explore new contrasts, new targets and new imaging techniques for NMD are described. The report is written by the scientists who attended the meetings and presented their data. An overview is given on the different contrasts that MRI can generate and their application, clinical needs and desired readouts, and emerging methods.
Collapse
Affiliation(s)
| | - Ericky C.A. Araujo
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | - Noura Azzabou
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | | | - Andrew Blamire
- Institute of Cellular Medicine, Newcastle University, Newcastle-upon-Tyne, UK
| | - Jedrek Burakiewicz
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Pierre G. Carlier
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | - Bruce Damon
- Vanderbilt University Medical Center, Nashville, USA
| | - Xeni Deligianni
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland & Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | | | - Arend Heerschap
- Radboud University Medical Center, Nijmegen, the Netherlands
| | | | | | | | | | | | - Benjamin Marty
- NMR Laboratory, Neuromuscular Investigation Center, Institute of Myology & NMR Laboratory, CEA/DRF/IBFJ/MIRCen, Paris, France
| | - Armin M. Nagel
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany & Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | | | | | - Francesco Santini
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland & Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | - Olivier Scheidegger
- Department of Neurology, Inselspital, Bern University Hospital, University of Bern, Switzerland
| | - Fritz Schick
- University of Tübingen, Section on Experimental Radiology, Tübingen, Germany
| | | | | | | | - Volker Straub
- Institute of Cellular Medicine, Newcastle University, Newcastle-upon-Tyne, UK
| | | | - Hermien E. Kan
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
10
|
Zhang YN, Fowler KJ, Ozturk A, Potu CK, Louie AL, Montes V, Henderson WC, Wang K, Andre MP, Samir AE, Sirlin CB. Liver fibrosis imaging: A clinical review of ultrasound and magnetic resonance elastography. J Magn Reson Imaging 2020; 51:25-42. [PMID: 30859677 PMCID: PMC6742585 DOI: 10.1002/jmri.26716] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 02/26/2019] [Accepted: 02/26/2019] [Indexed: 12/13/2022] Open
Abstract
Liver fibrosis is a histological hallmark of most chronic liver diseases, which can progress to cirrhosis and liver failure, and predisposes to hepatocellular carcinoma. Accurate diagnosis of liver fibrosis is necessary for prognosis, risk stratification, and treatment decision-making. Liver biopsy, the reference standard for assessing liver fibrosis, is invasive, costly, and impractical for surveillance and treatment response monitoring. Elastography offers a noninvasive, objective, and quantitative alternative to liver biopsy. This article discusses the need for noninvasive assessment of liver fibrosis and reviews the comparative advantages and limitations of ultrasound and magnetic resonance elastography techniques with respect to their basic concepts, acquisition, processing, and diagnostic performance. Variations in clinical contexts of use and common pitfalls associated with each technique are considered. In addition, current challenges and future directions to improve the diagnostic accuracy and clinical utility of elastography techniques are discussed. Level of Evidence: 5 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:25-42.
Collapse
Affiliation(s)
- Yingzhen N. Zhang
- Department of Radiology, Liver Imaging Group, University of California, San Diego, La Jolla, California, USA
| | - Kathryn J. Fowler
- Department of Radiology, Liver Imaging Group, University of California, San Diego, La Jolla, California, USA
| | - Arinc Ozturk
- Department of Radiology, Center for Ultrasound Research & Translation, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Chetan K. Potu
- Department of Radiology, Liver Imaging Group, University of California, San Diego, La Jolla, California, USA
| | - Ashley L. Louie
- Department of Radiology, Liver Imaging Group, University of California, San Diego, La Jolla, California, USA
| | - Vivian Montes
- Department of Radiology, Liver Imaging Group, University of California, San Diego, La Jolla, California, USA
| | - Walter C. Henderson
- Department of Radiology, Liver Imaging Group, University of California, San Diego, La Jolla, California, USA
| | - Kang Wang
- Department of Radiology, Liver Imaging Group, University of California, San Diego, La Jolla, California, USA
| | - Michael P. Andre
- Department of Radiology, University of California, San Diego, La Jolla, California, USA
| | - Anthony E. Samir
- Department of Radiology, Center for Ultrasound Research & Translation, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Claude B. Sirlin
- Department of Radiology, Liver Imaging Group, University of California, San Diego, La Jolla, California, USA
| |
Collapse
|
11
|
Runge JH, Hoelzl SH, Sudakova J, Dokumaci AS, Nelissen JL, Guenthner C, Lee J, Troelstra M, Fovargue D, Stoker J, Nederveen AJ, Nordsletten D, Sinkus R. A novel magnetic resonance elastography transducer concept based on a rotational eccentric mass: preliminary experiences with the gravitational transducer. ACTA ACUST UNITED AC 2019; 64:045007. [DOI: 10.1088/1361-6560/aaf9f8] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
12
|
Neumann W, Bichert A, Fleischhauer J, Stern A, Figuli R, Wilhelm M, Schad LR, Zöllner FG. A novel 3D printed mechanical actuator using centrifugal force for magnetic resonance elastography: Initial results in an anthropomorphic prostate phantom. PLoS One 2018; 13:e0205442. [PMID: 30296308 PMCID: PMC6175527 DOI: 10.1371/journal.pone.0205442] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 09/25/2018] [Indexed: 12/12/2022] Open
Abstract
This work demonstrates a new method for the generation of mechanical shear wave during magnetic resonance elastography (MRE) that creates greater forces at higher vibrational frequencies as opposed to conventionally used pneumatic transducers. We developed an MR-compatible pneumatic turbine with an eccentric mass that creates a sinusoidal centrifugal force. The turbine was assessed with respect to its technical parameters and evaluated for MRE on a custom-made anthropomorphic prostate phantom. The silicone-based tissue-mimicking materials of the phantom were selected with regard to their complex shear moduli examined by rheometric testing. The tissue-mimicking materials closely matched human soft tissue elasticity values with a complex shear modulus ranging from 3.21 kPa to 7.29 kPa. We acquired MRE images on this phantom at 3 T with actuation frequencies of 50, 60 Hz, 70 Hz, and 80 Hz. The turbine generated vibrational wave amplitudes sufficiently large to entirely penetrate the phantoms during the feasibility study. Increased wave length in the stiffer inclusions compared to softer background material were detected. Our initial results suggest that silicone-based phantoms are useful for the evaluation of elasticities during MRE. Furthermore, our turbine seems suitable for the mechanical assessment of soft tissue during MRE.
Collapse
Affiliation(s)
- Wiebke Neumann
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Andreas Bichert
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Jonas Fleischhauer
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Antonia Stern
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Roxana Figuli
- Institute for Chemical Technology and Polymer Chemistry of Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Manfred Wilhelm
- Institute for Chemical Technology and Polymer Chemistry of Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Lothar R. Schad
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Frank G. Zöllner
- Department of Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|
13
|
Abstract
The mechanical properties of soft tissues are closely associated with a variety of diseases. This motivates the development of elastography techniques in which tissue mechanical properties are quantitatively estimated through imaging. Magnetic resonance elastography (MRE) is a noninvasive phase-contrast MR technique wherein shear modulus of soft tissue can be spatially and temporally estimated. MRE has recently received significant attention due to its capability in noninvasively estimating tissue mechanical properties, which can offer considerable diagnostic potential. In this work, recent technology advances of MRE, its future clinical applications, and the related limitations will be discussed.
Collapse
Affiliation(s)
- Huiming Dong
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - Richard D. White
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA
- Department of Internal Medicine-Division of Cardiology, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA
| | - Arunark Kolipaka
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, 43210, USA
- Department of Internal Medicine-Division of Cardiology, The Ohio State University Wexner Medical Center, Columbus, OH, 43210, USA
| |
Collapse
|
14
|
Feng Y, Zhu M, Qiu S, Shen P, Ma S, Zhao X, Hu CH, Guo L. A multi-purpose electromagnetic actuator for magnetic resonance elastography. Magn Reson Imaging 2018; 51:29-34. [DOI: 10.1016/j.mri.2018.04.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Accepted: 04/15/2018] [Indexed: 01/17/2023]
|
15
|
Neumann W, Schad LR, Zollner FG. A novel 3D-printed mechanical actuator using centrifugal force for magnetic resonance elastography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2017:3541-3544. [PMID: 29060662 DOI: 10.1109/embc.2017.8037621] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Magnetic resonance elastography (MRE) is a technique for the quantification of tissue stiffness during MR examinations. It requires consistent methods for mechanical shear wave induction to the region of interest in the human body to reliably quantify elastic properties of soft tissues. This work proposes a novel 3D-printed mechanical actuator using the principle of centrifugal force for wave induction. The driver consists of a 3D-printed turbine vibrator powered by compressed air (located inside the scanner room) and an active driver controlling the pressure of inflowing air (placed outside the scanner room). The generated force of the proposed actuator increases for higher actuation frequencies as opposed to conventionally used air cushions. There, the displacement amplitude decreases with increasing actuation frequency resulting in a smaller signal-to-noise ratio. An initial phantom study is presented which demonstrates the feasibility of the actuator for MRE. The wave-actuation frequency was regulated in a range between 15 Hz and 60 Hz for force measurements and proved sufficiently stable (± 0.3 Hz) for any given nominal frequency. The generated forces depend on the weight of the eccentric unbalance within the turbine and ranged between 0.67 N to 2.70 N (for 15 Hz) and 3.09 N to 7.77 N (for 60 Hz). Therefore, the generated force of the presented actuator increases with rotational speed of the turbine and offers an elegant solution for sufficiently large wave actuation at higher frequencies. In future work, we will investigate an optimal ratio of the weight of unbalance to the size of turbine for appropriately large but tolerable wave actuation for a given nominal frequency.
Collapse
|
16
|
Bosshard JC, Yallapragada N, McDougall MP, Wright SM. Exploration of highly accelerated magnetic resonance elastography using high-density array coils. Quant Imaging Med Surg 2017; 7:195-204. [PMID: 28516045 PMCID: PMC5418148 DOI: 10.21037/qims.2017.04.02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Accepted: 04/07/2017] [Indexed: 11/06/2022]
Abstract
BACKGROUND Magnetic resonance elastography (MRE) measures tissue mechanical properties by applying a shear wave and capturing its propagation using magnetic resonance imaging (MRI). By using high density array coils, MRE images are acquired using single echo acquisition (SEA) and at high resolutions with significantly reduced scan times. METHODS Sixty-four channel uniplanar and 32×32 channel biplanar receive arrays are used to acquire MRE wave image sets from agar samples containing regions of varying stiffness. A mechanical actuator triggered by a stepped delay time introduces vibrations into the sample while a motion sensitizing gradient encodes micrometer displacements into the phase. SEA imaging is used to acquire each temporal offset in a single echo, while multiple echoes from the same array are employed for highly accelerated imaging at high resolutions. Additionally, stiffness variations as a function of temperature are studied by using a localized heat source above the sample. A custom insertable gradient coil is employed for phase compensation of SEA imaging with the biplanar array to allow imaging of multiple slices. RESULTS SEA MRE images show a mechanical shear wave propagating into and across agar samples. A set of 720 images was obtained in 720 echoes, plus a single reference scan for both harmonic and transient MRE. A set of 2,950 wave image frames was acquired from pairs of SEA images captured during heating, showing the change in mechanical wavelength with the change in agar properties. A set of 240 frames was acquired from two slices simultaneously using the biplanar array, with phase images processed into displacement maps. Combining the narrow sensitivity patterns and SNR advantage of the SEA array coil geometry allowed acquisition of a data set with a resolution of 156 µm × 125 µm × 1,000 µm in only 64 echoes, demonstrating high resolution and high acceleration factors. CONCLUSIONS MRE using high-density arrays offers the unique ability to acquire a single frame of a propagating mechanical vibration with each echo, which may be helpful in non-repeatable or destructive testing. Highly accelerated, high resolution MRE may be enabled by the use of large arrays of coils such as used for SEA, but at lower acceleration rates supporting the higher resolution than provided by SEA imaging.
Collapse
Affiliation(s)
- John C. Bosshard
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA
| | - Naresh Yallapragada
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA
| | - Mary P. McDougall
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Steven M. Wright
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
- Department of Radiology, Texas A&M Health Science Center, Bryan, TX, USA
| |
Collapse
|
17
|
Low G, Kruse SA, Lomas DJ. General review of magnetic resonance elastography. World J Radiol 2016; 8:59-72. [PMID: 26834944 PMCID: PMC4731349 DOI: 10.4329/wjr.v8.i1.59] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Revised: 11/14/2015] [Accepted: 12/04/2015] [Indexed: 02/06/2023] Open
Abstract
Magnetic resonance elastography (MRE) is an innovative imaging technique for the non-invasive quantification of the biomechanical properties of soft tissues via the direct visualization of propagating shear waves in vivo using a modified phase-contrast magnetic resonance imaging (MRI) sequence. Fundamentally, MRE employs the same physical property that physicians utilize when performing manual palpation - that healthy and diseased tissues can be differentiated on the basis of widely differing mechanical stiffness. By performing “virtual palpation”, MRE is able to provide information that is beyond the capabilities of conventional morphologic imaging modalities. In an era of increasing adoption of multi-parametric imaging approaches for solving complex problems, MRE can be seamlessly incorporated into a standard MRI examination to provide a rapid, reliable and comprehensive imaging evaluation at a single patient appointment. Originally described by the Mayo Clinic in 1995, the technique represents the most accurate non-invasive method for the detection and staging of liver fibrosis and is currently performed in more than 100 centers worldwide. In this general review, the mechanical properties of soft tissues, principles of MRE, clinical applications of MRE in the liver and beyond, and limitations and future directions of this discipline -are discussed. Selected diagrams and images are provided for illustration.
Collapse
|
18
|
Sahebjavaher RS, Nir G, Gagnon LO, Ischia J, Jones EC, Chang SD, Yung A, Honarvar M, Fazli L, Goldenberg SL, Rohling R, Sinkus R, Kozlowski P, Salcudean SE. MR elastography and diffusion-weighted imaging of ex vivo prostate cancer: quantitative comparison to histopathology. NMR IN BIOMEDICINE 2015; 28:89-100. [PMID: 25382459 PMCID: PMC5478374 DOI: 10.1002/nbm.3203] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2013] [Revised: 08/10/2014] [Accepted: 08/13/2014] [Indexed: 05/29/2023]
Abstract
The purpose of this work was (1) to develop a magnetic resonance elastography (MRE) system for imaging of the ex vivo human prostate and (2) to assess the diagnostic power of mono-frequency and multi-frequency MRE and diffusion weighted imaging (DWI) alone and combined as correlated with histopathology in a patient study. An electromagnetic driver was designed specifically for MRE studies in small-bore MR scanners. Ex vivo prostate specimens (post-fixation) of 14 patients who underwent radical prostatectomy were imaged with MRE at 7 T (nine cases had DWI). In six patients, the MRE examination was performed at three frequencies (600, 800, 1000 Hz) to extract the power-law exponent Gamma. The images were registered to wholemount pathology slides marked with the Gleason score. The areas under the receiver-operator-characteristic curves (AUC) were calculated. The methods were validated in a phantom study and it was demonstrated that (i) the driver does not interfere with the acquisition process and (ii) the driver can generate amplitudes greater than 100 µm for frequencies less than 1 kHz. In the quantitative study, cancerous tissue with Gleason score at least 3 + 3 was distinguished from normal tissue in the peripheral zone (PZ) with an average AUC of 0.75 (Gd ), 0.75 (Gl ), 0.70 (Gamma-Gd ), 0.68 (apparent diffusion coefficient, ADC), and 0.82 (Gd + Gl + ADC). The differentiation between PZ and central gland was modest for Gd (p < 0.07), Gl (p < 0.06) but not significant for Gamma (p < 0.2). A correlation of 0.4 kPa/h was found between the fixation time of the prostate specimen and the stiffness of the tissue, which could affect the diagnostic power results. DWI and MRE may provide complementary information; in fact MRE performed better than ADC in distinguishing normal from cancerous tissue in some cases. Multi-frequency (Gamma) analysis did not appear to improve the results. However, in light of the effect of tissue fixation, the clinical implication of our results may be inconclusive and more experiments are needed.
Collapse
Affiliation(s)
- Ramin S Sahebjavaher
- University of British Columbia, Electrical and Computer Engineering, Vancouver, BC, Canada
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Zhao H, Song P, Meixner DD, Kinnick RR, Callstrom MR, Sanchez W, Urban MW, Manduca A, Greenleaf JF, Chen S. External vibration multi-directional ultrasound shearwave elastography (EVMUSE): application in liver fibrosis staging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2014; 33:2140-8. [PMID: 25020066 PMCID: PMC4216646 DOI: 10.1109/tmi.2014.2332542] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Shear wave speed can be used to assess tissue elasticity, which is associated with tissue health. Ultrasound shear wave elastography techniques based on measuring the propagation speed of the shear waves induced by acoustic radiation force are becoming promising alternatives to biopsy in liver fibrosis staging. However, shear waves generated by such methods are typically very weak. Therefore, the penetration may become problematic, especially for overweight or obese patients. In this study, we developed a new method called external vibration multi-directional ultrasound shearwave elastography (EVMUSE), in which external vibration from a loudspeaker was used to generate a multi-directional shear wave field. A directional filter was then applied to separate the complex shear wave field into several shear wave fields propagating in different directions. A 2-D shear wave speed map was reconstructed from each individual shear wave field, and a final 2-D shear wave speed map was constructed by compounding these individual wave speed maps. The method was validated using two homogeneous phantoms and one multi-purpose tissue-mimicking phantom. Ten patients undergoing liver magnetic resonance elastography (MRE) were also studied with EVMUSE to compare results between the two methods. Phantom results showed EVMUSE was able to quantify tissue elasticity accurately with good penetration. In vivo EVMUSE results were well correlated with MRE results, indicating the promise of using EVMUSE for liver fibrosis staging.
Collapse
Affiliation(s)
- Heng Zhao
- Mayo Clinic College of Medicine, Rochester, MN 55905 USA. He is now with Sonavation Inc., Palm Beach Gardens, FL 33410 USA
| | - Pengfei Song
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN 55905 USA
| | - Duane D. Meixner
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, MN 55905 USA
| | - Randall R. Kinnick
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN 55905 USA
| | - Matthew R. Callstrom
- Department of Radiology, Mayo Clinic College of Medicine, Rochester, MN 55905 USA
| | - William Sanchez
- Department of Gastroenterology and Hepatology, Mayo Clinic College of Medicine, Rochester, MN 55905 USA
| | - Matthew W. Urban
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN 55905 USA
| | - Armando Manduca
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN 55905 USA
| | - James F. Greenleaf
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN 55905 USA
| | - Shigao Chen
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN 55905 USA
| |
Collapse
|
20
|
Abstract
Magnetic resonance elastography (MRE) assesses tissue stiffness in vivo by imaging propagating shear waves through the tissues and processing the wave information. MRE is a robust technology with excellent technical success; is applicable in almost all patients and body habitus; and has excellent reproducibility, repeatability, and interobserver agreement for assessing liver stiffness. It is currently the most accurate noninvasive technique for detection and staging of liver fibrosis and has the potential to replace liver biopsy. This article describes the principles and technique of MRE, current clinical applications, and emerging clinical indications.
Collapse
Affiliation(s)
- Sudhakar Kundapur Venkatesh
- Department of Radiology, Mayo Clinic College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
| | - Richard L Ehman
- Department of Radiology, Mayo Clinic College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| |
Collapse
|
21
|
Xiang K, Zhu XL, Wang CX, Li BN. MREJ: MRE elasticity reconstruction on ImageJ. Comput Biol Med 2013; 43:847-52. [PMID: 23746726 DOI: 10.1016/j.compbiomed.2013.04.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Revised: 04/02/2013] [Accepted: 04/03/2013] [Indexed: 01/22/2023]
Abstract
Magnetic resonance elastography (MRE) is a promising method for health evaluation and disease diagnosis. It makes use of elastic waves as a virtual probe to quantify soft tissue elasticity. The wave actuator, imaging modality and elasticity interpreter are all essential components for an MRE system. Efforts have been made to develop more effective actuating mechanisms, imaging protocols and reconstructing algorithms. However, translating MRE wave images into soft tissue elasticity is a nontrivial issue for health professionals. This study contributes an open-source platform - MREJ - for MRE image processing and elasticity reconstruction. It is established on the widespread image-processing program ImageJ. Two algorithms for elasticity reconstruction were implemented with spatiotemporal directional filtering. The usability of the method is shown through virtual palpation on different phantoms and patients. Based on the results, we conclude that MREJ offers the MRE community a convenient and well-functioning program for image processing and elasticity interpretation.
Collapse
Affiliation(s)
- Kui Xiang
- School of Automation, Wuhan University of Technology, Wuhan, China
| | | | | | | |
Collapse
|
22
|
Guérin G, Turquier F. Impact of the defect size, the mesh overlap and the fixation depth on ventral hernia repairs: a combined experimental and numerical approach. Hernia 2013; 17:647-55. [PMID: 23456147 DOI: 10.1007/s10029-013-1050-6] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2011] [Accepted: 01/19/2013] [Indexed: 10/27/2022]
Abstract
BACKGROUND Ventral hernia repairs (VHRs) still exhibit clinical complications in terms of recurrence, pain, and discomfort. Factors such as surgical technique or mesh features are thought to be highly influent. The aim was to evaluate the impact of the defect size, the mesh overlap and the fixation depth on VHR using both physical and numerical models. METHODS The physical model was developed to mimic a passive abdominal wall. Healthy, damaged, and repaired configurations were evaluated using a spherical plunger. The associated numerical (Finite Elements) model was first loaded by a plunger for validation. A parametric study was then conducted with the numerical model loaded by a uniform pressure. Two defect sizes (3.5 × 5 cm and 8.25 × 12 cm elliptic shape), two overlaps (2 and 5 cm), and two fixation depths (peritoneum or muscle) were investigated for both passive and active abdominal walls. RESULTS With the physical model, the repaired configuration was 22 % stiffer than the damaged configuration. The statistical analysis of the parametric study showed that the defect size was the most influential parameter regarding the stress in the mesh, the bulging and the pull-out force at the fixation points. The overlap was influential in terms of stress in the mesh. The fixation depth was not influential. These trends increased with the abdominal wall activity. CONCLUSION Increase of the defect size and decrease of the overlap affected significantly the VHR mechanical performances. Such numerical models could help to better understand the behavior of the repaired abdominal wall and finally to reduce the clinical complications.
Collapse
Affiliation(s)
- G Guérin
- Covidien-Surgical Solutions, Research and Development, 116 Avenue du Formans, 01600, Trévoux, France,
| | | |
Collapse
|
23
|
Glaser KJ, Manduca A, Ehman RL. Review of MR elastography applications and recent developments. J Magn Reson Imaging 2012; 36:757-74. [PMID: 22987755 PMCID: PMC3462370 DOI: 10.1002/jmri.23597] [Citation(s) in RCA: 160] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
The technique of MR elastography (MRE) has emerged as a useful modality for quantitatively imaging the mechanical properties of soft tissues in vivo. Recently, MRE has been introduced as a clinical tool for evaluating chronic liver disease, but many other potential applications are being explored. These applications include measuring tissue changes associated with diseases of the liver, breast, brain, heart, and skeletal muscle including both focal lesions (e.g., hepatic, breast, and brain tumors) and diffuse diseases (e.g., fibrosis and multiple sclerosis). The purpose of this review article is to summarize some of the recent developments of MRE and to highlight some emerging applications.
Collapse
Affiliation(s)
| | - Armando Manduca
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
24
|
Convertible pneumatic actuator for magnetic resonance elastography of the brain. Magn Reson Imaging 2010; 29:147-52. [PMID: 20833495 DOI: 10.1016/j.mri.2010.07.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2010] [Revised: 07/06/2010] [Accepted: 07/13/2010] [Indexed: 12/12/2022]
Abstract
Here we present a novel pneumatic actuator design for brain magnetic resonance elastography (MRE). Magnetic resonance elastography is a phase contrast technique capable of tracing strain wave propagation and utilizing this information for the calculation of mechanical properties of materials and living tissues. In MRE experiments, the acoustic waves are generated in a synchronized way with respect to image acquisition, using various types of mechanical actuators. The unique feature of the design is its simplicity and flexibility, which allows reconfiguration of the actuator for different applications ranging from in vivo brain MRE to experiments with phantoms. Phantom and in vivo data are presented to demonstrate actuator performance.
Collapse
|
25
|
Pattison AJ, Lollis SS, Perriñez PR, Perreard IM, McGarry MDJ, Weaver JB, Paulsen KD. Time-harmonic magnetic resonance elastography of the normal feline brain. J Biomech 2010; 43:2747-52. [PMID: 20655045 DOI: 10.1016/j.jbiomech.2010.06.008] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2009] [Revised: 04/22/2010] [Accepted: 06/07/2010] [Indexed: 11/15/2022]
Abstract
Imaging of the mechanical properties of in vivo brain tissue could eventually lead to non-invasive diagnosis of hydrocephalus, Alzheimer's disease and other pathologies known to alter the intracranial environment. The purpose of this work is to (1) use time-harmonic magnetic resonance elastography (MRE) to estimate the mechanical property distribution of cerebral tissue in the normal feline brain and (2) compare the recovered properties of grey and white matter. Various in vivo and ex vivo brain tissue property measurement strategies have led to the highly variable results that have been reported in the literature. MR elastography is an imaging technique that can estimate mechanical properties of tissue non-invasively and in vivo. Data was acquired in 14 felines and elastic parameters were estimated using a globo-regional nonlinear image reconstruction algorithm. Results fell within the range of values reported in the literature and showed a mean shear modulus across the subject group of 7-8 kPa with all but one animal falling within 5-15 kPa. White matter was statistically stiffer (p<0.01) than grey matter by about 1 kPa on a per subject basis. To the best of our knowledge, the results reported represent the most extensive set of estimates in the in vivo brain which have been based on MRE acquisition of the three-dimensional displacement field coupled to volumetric shear modulus image reconstruction achieved through nonlinear parameter estimation. However, the inter-subject variation in mean shear modulus indicates the need for further study, including the possibility of applying more advanced models to estimate the relevant tissue mechanical properties from the data.
Collapse
Affiliation(s)
- A J Pattison
- Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
| | | | | | | | | | | | | |
Collapse
|
26
|
Tse ZTH, Janssen H, Hamed A, Ristic M, Young I, Lamperth M. Magnetic resonance elastography hardware design: A survey. Proc Inst Mech Eng H 2009; 223:497-514. [DOI: 10.1243/09544119jeim529] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Magnetic resonance elastography (MRE) is an emerging technique capable of measuring the shear modulus of tissue. A suspected tumour can be identified by comparing its properties with those of tissues surrounding it; this can be achieved even in deep-lying areas as long as mechanical excitation is possible. This would allow non-invasive methods for cancer-related diagnosis in areas not accessible with conventional palpation. An actuating mechanism is required to generate the necessary tissue displacements directly on the patient in the scanner and three different approaches, in terms of actuator action and position, exist to derive stiffness measurements. However, the magnetic resonance (MR) environment places considerable constraints on the design of such devices, such as the possibility of mutual interference between electrical components, the scanner field, and radio frequency pulses, and the physical space restrictions of the scanner bore. This paper presents a review of the current solutions that have been developed for MRE devices giving particular consideration to the design criteria including the required vibration frequency and amplitude in different applications, the issue of MR compatibility, actuation principles, design complexity, and scanner synchronization issues. The future challenges in this field are also described.
Collapse
Affiliation(s)
- Z T H Tse
- Department of Mechanical Engineering, Imperial College London, London, UK
| | - H Janssen
- Department of Mechanical Engineering, Imperial College London, London, UK
| | - A Hamed
- Department of Mechanical Engineering, Imperial College London, London, UK
| | - M Ristic
- Department of Mechanical Engineering, Imperial College London, London, UK
| | - I Young
- Department of Mechanical Engineering, Imperial College London, London, UK
| | - M Lamperth
- Department of Mechanical Engineering, Imperial College London, London, UK
| |
Collapse
|
27
|
Affiliation(s)
- Roger Gassert
- Department of Bioengineering, Imperial College, London, UK.
| | | | | |
Collapse
|