1
|
Shepherd J. Biomimetic Approaches in the Development of Optimised 3D Culture Environments for Drug Discovery in Cardiac Disease. Biomimetics (Basel) 2025; 10:204. [PMID: 40277603 PMCID: PMC12024959 DOI: 10.3390/biomimetics10040204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2024] [Revised: 03/09/2025] [Accepted: 03/21/2025] [Indexed: 04/26/2025] Open
Abstract
Cardiovascular disease remains the leading cause of death worldwide, yet despite massive investment in drug discovery, the progress of cardiovascular drugs from lab to clinic remains slow. It is a complex, costly pathway from drug discovery to the clinic and failure becomes more expensive as a drug progresses along this pathway. The focus has begun to shift to optimisation of in vitro culture methodologies, not only because these must be undertaken are earlier on in the drug discovery pathway, but also because the principles of the 3Rs have become embedded in national and international legislation and regulation. Numerous studies have shown myocyte cell behaviour to be much more physiologically relevant in 3D culture compared to 2D culture, highlighting the advantages of using 3D-based models, whether microfluidic or otherwise, for preclinical drug screening. This review aims to provide an overview of the challenges in cardiovascular drug discovery, the limitations of traditional routes, and the successes in the field of preclinical models for cardiovascular drug discovery. It focuses on the particular role biomimicry can play, but also the challenges around implementation within commercial drug discovery.
Collapse
Affiliation(s)
- Jenny Shepherd
- School of Engineering, University of Leicester, Leicester LE1 7RH, UK
| |
Collapse
|
2
|
Miklavčič D, Verma A, Krahn PRP, Štublar J, Kos B, Escartin T, Lombergar P, Coulombe N, Terricabras M, Jarm T, Kranjc M, Barry J, Mattison L, Kirchhof N, Sigg DC, Stewart M, Wright G. Biophysics and electrophysiology of pulsed field ablation in normal and infarcted porcine cardiac ventricular tissue. Sci Rep 2024; 14:32063. [PMID: 39738639 PMCID: PMC11686391 DOI: 10.1038/s41598-024-83683-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Accepted: 12/16/2024] [Indexed: 01/02/2025] Open
Abstract
Pulsed Field Ablation (PFA) is a new ablation method being rapidly adopted for treatment of atrial fibrillation, which shows advantages in safety and efficiency over radiofrequency and cryo-ablation. In this study, we used an in vivo swine model (10 healthy and 5 with chronic myocardial infarct) for ventricular PFA, collecting intracardiac electrograms, electro-anatomical maps, native T1-weighted and late gadolinium enhancement MRI, gross pathology, and histology. We used 1000-1500 V pulses, with 1-16 pulse trains to vary PFA dose. Lesions were assessed at 24 h, 7 days, and 6 weeks in healthy and at 48 h in infarcted ventricles. Comparisons of lesion sizes using a numerical model enabled us to determine lethal electric field thresholds for cardiac tissue and its dependence on the number of pulse trains. Similar thresholds were found in normal and infarcted hearts. Numerical modeling and temperature-sensitive MRI confirmed the nonthermal nature of PFA, with less than 2% of a lesion's volume at the highest dose used being attributed to thermal damage. Longitudinal cardiac MRI and histology provide a comprehensive description of lesion maturation. Lesions shrink between 24 h and 7 days post-ablation and then remain stable out to 6 weeks post-ablation. Periprocedural electrograms analysis yields good correlation with lesion durability and size.
Collapse
Affiliation(s)
- Damijan Miklavčič
- Faculty of Electrical Engineering, University of Ljubljana, Trzaska 25, Ljubljana, Slovenia.
| | - Atul Verma
- McGill University Health Centre, McGill University, Montreal, Canada
| | - Philippa R P Krahn
- Sunnybrook Research Institute, Toronto, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Jernej Štublar
- Faculty of Electrical Engineering, University of Ljubljana, Trzaska 25, Ljubljana, Slovenia
- Department of Cardiology Cardiovascular Surgery, University Clinical Medical Centre, Ljubljana, Slovenia
| | - Bor Kos
- Faculty of Electrical Engineering, University of Ljubljana, Trzaska 25, Ljubljana, Slovenia
| | - Terenz Escartin
- Sunnybrook Research Institute, Toronto, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
| | - Peter Lombergar
- Faculty of Electrical Engineering, University of Ljubljana, Trzaska 25, Ljubljana, Slovenia
| | | | | | - Tomaž Jarm
- Faculty of Electrical Engineering, University of Ljubljana, Trzaska 25, Ljubljana, Slovenia
| | - Matej Kranjc
- Faculty of Electrical Engineering, University of Ljubljana, Trzaska 25, Ljubljana, Slovenia
| | | | | | | | | | | | - Graham Wright
- Sunnybrook Research Institute, Toronto, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
3
|
Gallet J, Sassaroli E, Yuan Q, Aljabal A, Park MA. Quality Assurance of Point and 2D Shear Wave Elastography through the Establishment of Baseline Data Using Phantoms. SENSORS (BASEL, SWITZERLAND) 2024; 24:4961. [PMID: 39124008 PMCID: PMC11314857 DOI: 10.3390/s24154961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Revised: 07/09/2024] [Accepted: 07/23/2024] [Indexed: 08/12/2024]
Abstract
Ultrasound elastography has been available on most modern systems; however, the implementation of quality processes tends to be ad hoc. It is essential for a medical physicist to benchmark elastography measurements on each system and track them over time, especially after major software upgrades or repairs. This study aims to establish baseline data using phantoms and monitor them for quality assurance in elastography. In this paper, we utilized two phantoms: a set of cylinders, each with a composite material with varying Young's moduli, and an anthropomorphic abdominal phantom containing a liver modeled to represent early-stage fibrosis. These phantoms were imaged using three ultrasound manufacturers' elastography functions with either point or 2D elastography. The abdominal phantom was also imaged using magnetic resonance elastography (MRE) as it is recognized as the non-invasive gold standard for staging liver fibrosis. The scaling factor was determined based on the data acquired using MR and US elastography from the same vendor. The ultrasound elastography measurements showed inconsistency between different manufacturers, but within the same manufacturer, the measurements showed high repeatability. In conclusion, we have established baseline data for quality assurance procedures and specified the criteria for the acceptable range in liver fibrosis phantoms during routine testing.
Collapse
Affiliation(s)
- Jacqueline Gallet
- Department of Radiology, Division of Medical Physics, UT Southwestern Medical Center, Dallas, TX 75390, USA; (Q.Y.); (A.A.)
| | | | - Qing Yuan
- Department of Radiology, Division of Medical Physics, UT Southwestern Medical Center, Dallas, TX 75390, USA; (Q.Y.); (A.A.)
| | - Areej Aljabal
- Department of Radiology, Division of Medical Physics, UT Southwestern Medical Center, Dallas, TX 75390, USA; (Q.Y.); (A.A.)
| | - Mi-Ae Park
- Department of Radiology, Division of Medical Physics, UT Southwestern Medical Center, Dallas, TX 75390, USA; (Q.Y.); (A.A.)
| |
Collapse
|
4
|
Dong Z, Lok UW, Lowerison MR, Huang C, Chen S, Song P. Three-Dimensional Shear Wave Elastography Using Acoustic Radiation Force and a 2-D Row-Column Addressing (RCA) Array. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:448-458. [PMID: 38363671 DOI: 10.1109/tuffc.2024.3366540] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/18/2024]
Abstract
Acoustic radiation force (ARF)-based shear wave elastography (SWE) is a clinically available ultrasound imaging mode that noninvasively and quantitatively measures tissue stiffness. Current implementations of ARF-SWE are largely limited to 2-D imaging, which does not provide a robust estimation of heterogeneous tissue mechanical properties. Existing 3-D ARF-SWE solutions that are clinically available are based on wobbler probes, which cannot provide true 3-D shear wave motion detection. Although 3-D ARF-SWE based on 2-D matrix arrays have been previously demonstrated, they do not provide a practical solution because of the need for a high channel-count ultrasound system (e.g., 1024-channel) to provide adequate volume rates and the delicate circuitries (e.g., multiplexers) that are vulnerable to the long-duration "push" pulses. To address these issues, here we propose a new 3-D ARF-SWE method based on the 2-D row-column addressing (RCA) array which has a much lower element count (e.g., 256), provides an ultrafast imaging volume rate (e.g., 2000 Hz), and can withstand the push pulses. In this study, we combined the comb-push shear elastography (CUSE) technique with 2-D RCA for enhanced SWE imaging field-of-view (FOV). In vitro phantom studies demonstrated that the proposed method had robust 3-D SWE performance in both homogenous and inclusion phantoms. An in vivo study on a breast cancer patient showed that the proposed method could reconstruct 3-D elasticity maps of the breast lesion, which was validated using a commercial ultrasound scanner. These results demonstrate strong potential for the proposed method to provide a viable and practical solution for clinical 3-D ARF-SWE.
Collapse
|
5
|
Petrescu A, Voigt JU. [Echocardiography with high frame rates in the clinical practice : Principles, applications and perspectives]. Herz 2023; 48:339-351. [PMID: 37530782 DOI: 10.1007/s00059-023-05199-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/16/2023] [Indexed: 08/03/2023]
Abstract
Continuous developments in cardiovascular imaging, software and hardware have led to technological advancements that open new ways for assessing myocardial mechanics, hemodynamics, and function. Through new scan modalities, echocardiographic scanners can nowadays achieve very high frame rates up to 5000 frames s-1 which enables a wide variety of new applications, including shear wave elastography, ultrafast speckle tracking, the visualization of intracardiac blood flow and myocardial perfusion imaging. This review provides an overview of these advances and demonstrates possible applications and their potential added value in the clinical practice.
Collapse
Affiliation(s)
- Aniela Petrescu
- Abteilung für Kardiologie, Universitätsmedizin Mainz, Mainz, Deutschland
| | - Jens-Uwe Voigt
- Department of Cardiology, University Hospital Leuven, University of Leuven, Herestraat 49, 3000, Leuven, Belgien.
| |
Collapse
|
6
|
Lee S, Eun LY, Hwang JY, Kim JS, Eun Y. New Metric to Evaluate Cardiac Anisotropic Mechanics by Directional High-Frequency Ultrasound-Based Transverse Wave Elastography. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:653-667. [PMID: 37220030 DOI: 10.1109/tuffc.2023.3279284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The evaluation of cardiac anisotropic mechanics is important in the diagnosis of heart disease. However, other representative ultrasound imaging-based metrics, which are capable of quantitatively evaluating anisotropic cardiac mechanics, are insufficient for accurately diagnosing heart disease due to the influence of viscosity and geometry of cardiac tissues. In this study, we propose a new ultrasound imaging-based metric, maximum cosine similarity (MaxCosim), for quantifying anisotropic mechanics of cardiac tissues by evaluating the periodicity of the transverse wave speeds depending on the measurement directions using ultrasound imaging. We developed a high-frequency ultrasound-based directional transverse wave imaging system to measure the transverse wave speed in multiple directions. The ultrasound imaging-based metric was validated by performing experiments on 40 rats randomly assigned to four groups; three doxorubicin (DOX) treatment groups received 10, 15, or 20 mg/kg DOX, while the control group received 0.2 mL/kg saline. In each heart sample, the developed ultrasound imaging system allowed measuring transverse wave speeds in multiple directions, and the new metric was then calculated from 3-D ultrasound transverse wave images to evaluate the degree of anisotropic mechanics of the heart sample. The results of the metric were compared with histopathological changes for validation. A decrease in the MaxCosim value was observed in the DOX treatment groups, with the degree of decrease depending on the dose. These results are consistent with the histopathological features, suggesting that our ultrasound imaging-based metric can quantify the anisotropic mechanics of cardiac tissues and potentially be used for the early diagnosis of heart disease.
Collapse
|
7
|
Dong J, Zhao J, Liu X, Lee WN. Nondestructive ultrasound evaluation of microstructure-related material parameters of skeletal muscle: An in silico and in vitro study. J Mech Behav Biomed Mater 2023; 142:105807. [PMID: 37030170 DOI: 10.1016/j.jmbbm.2023.105807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 03/16/2023] [Accepted: 03/24/2023] [Indexed: 03/31/2023]
Abstract
Direct and nondestructive assessment of material properties of skeletal muscle in vivo shall advance our understanding of intact muscle mechanics and facilitate personalized interventions. However, this is challenged by intricate hierarchical microstructure of the skeletal muscle. We have previously regarded the skeletal muscle as a composite of myofibers and extracellular matrix (ECM), formulated shear wave propagation in the undeformed muscle using the acoustoelastic theory, and preliminarily demonstrated that ultrasound-based shear wave elastography (SWE) could estimate microstructure-related material parameters (MRMPs): myofiber stiffness μf, ECM stiffness μm, and myofiber volume ratio Vf. The proposed method warrants further validation but is hampered by the lack of ground truth values of MRMPs. In this study, we presented analytical and experimental validations of the proposed method using finite-element (FE) simulations and 3D-printed hydrogel phantoms, respectively. Three combinations of different physiologically relevant MRMPs were used in the FE simulations where shear wave propagations in the corresponding composite media were simulated. Two 3D-printed hydrogel phantoms with the MRMPs close to those of a real skeletal muscle (i.e., μf=2.02kPa, μm=52.42kPa, and Vf=0.675,0.832) for ultrasound imaging were fabricated by an alginate-based hydrogel printing protocol that we modified and optimized from the freeform reversible embedding of suspended hydrogels (FRESH) method in literature. Average percent errors of (μf,μm,Vf) estimates were found to be (2.7%,7.3%,2.4%)in silico and (3.0%,8.0%,9.9%)in vitro. This quantitative study corroborated the potential of our proposed theoretical model along with ultrasound SWE for uncovering microstructural characteristics of the skeletal muscle in an entirely nondestructive way.
Collapse
|
8
|
Dejea H, Schlepütz CM, Méndez-Carmona N, Arnold M, Garcia-Canadilla P, Longnus SL, Stampanoni M, Bijnens B, Bonnin A. A tomographic microscopy-compatible Langendorff system for the dynamic structural characterization of the cardiac cycle. Front Cardiovasc Med 2022; 9:1023483. [PMID: 36620622 PMCID: PMC9815149 DOI: 10.3389/fcvm.2022.1023483] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 12/07/2022] [Indexed: 12/24/2022] Open
Abstract
Introduction Cardiac architecture has been extensively investigated ex vivo using a broad spectrum of imaging techniques. Nevertheless, the heart is a dynamic system and the structural mechanisms governing the cardiac cycle can only be unveiled when investigating it as such. Methods This work presents the customization of an isolated, perfused heart system compatible with synchrotron-based X-ray phase contrast imaging (X-PCI). Results Thanks to the capabilities of the developed setup, it was possible to visualize a beating isolated, perfused rat heart for the very first time in 4D at an unprecedented 2.75 μm pixel size (10.6 μm spatial resolution), and 1 ms temporal resolution. Discussion The customized setup allows high-spatial resolution studies of heart architecture along the cardiac cycle and has thus the potential to serve as a tool for the characterization of the structural dynamics of the heart, including the effects of drugs and other substances able to modify the cardiac cycle.
Collapse
Affiliation(s)
- Hector Dejea
- Paul Scherrer Institute, Villigen, Switzerland,Institute for Biomedical Engineering, University and ETH Zürich, Zurich, Switzerland,*Correspondence: Hector Dejea ✉
| | | | - Natalia Méndez-Carmona
- Department of Cardiac Surgery, Inselspital, Bern University Hospital, Bern, Switzerland,Department for BioMedical Research, University of Bern, Bern, Switzerland
| | - Maria Arnold
- Department of Cardiac Surgery, Inselspital, Bern University Hospital, Bern, Switzerland,Department for BioMedical Research, University of Bern, Bern, Switzerland
| | - Patricia Garcia-Canadilla
- BCNatal-Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Sant Joan de Déu and Hospital Clínic, University of Barcelona, Barcelona, Spain,Cardiovascular Diseases and Child Development, Institut de Recerca Sant Joan de Déu, Esplugues de Llobregat, Spain
| | - Sarah L. Longnus
- Department of Cardiac Surgery, Inselspital, Bern University Hospital, Bern, Switzerland,Department for BioMedical Research, University of Bern, Bern, Switzerland
| | - Marco Stampanoni
- Paul Scherrer Institute, Villigen, Switzerland,Institute for Biomedical Engineering, University and ETH Zürich, Zurich, Switzerland
| | - Bart Bijnens
- Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain,Institution for Research and Advanced Studies (ICREA), Barcelona, Spain
| | - Anne Bonnin
- Paul Scherrer Institute, Villigen, Switzerland
| |
Collapse
|
9
|
Ngo HHP, Poulard T, Brum J, Gennisson JL. Anisotropy in ultrasound shear wave elastography: An add-on to muscles characterization. Front Physiol 2022; 13:1000612. [PMID: 36246132 PMCID: PMC9554096 DOI: 10.3389/fphys.2022.1000612] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 09/05/2022] [Indexed: 11/25/2022] Open
Abstract
Ultrasound shear wave elastography was developed the past decade, bringing new stiffness biomarker in clinical practice. This biomarker reveals to be of primarily importance for the diagnosis of breast cancer or liver fibrosis. In muscle this biomarker become much more complex due to the nature of the muscle itself: an anisotropic medium. In this manuscript we depict the underlying theory of propagating waves in such anisotropic medium. Then we present the available methods that can consider and quantify this parameter. Advantages and drawbacks are discussed to open the way to imagine new methods that can free this biomarker in a daily clinical practice.
Collapse
Affiliation(s)
- Ha-Hien-Phuong Ngo
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Laboratoire d’Imagerie Médicale Multimodale à Paris-Saclay, Orsay, France
| | - Thomas Poulard
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Laboratoire d’Imagerie Médicale Multimodale à Paris-Saclay, Orsay, France
| | - Javier Brum
- Laboratorio de Acústica Ultrasonora, Instituto de Física, Facultad de Ciencias, Universidad de la República, Montevideo, Uruguay
| | - Jean- Luc Gennisson
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Laboratoire d’Imagerie Médicale Multimodale à Paris-Saclay, Orsay, France
- *Correspondence: Jean- Luc Gennisson,
| |
Collapse
|
10
|
Wilson AJ, Sands GB, LeGrice IJ, Young AA, Ennis DB. Myocardial mesostructure and mesofunction. Am J Physiol Heart Circ Physiol 2022; 323:H257-H275. [PMID: 35657613 PMCID: PMC9273275 DOI: 10.1152/ajpheart.00059.2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 05/23/2022] [Accepted: 05/23/2022] [Indexed: 11/22/2022]
Abstract
The complex and highly organized structural arrangement of some five billion cardiomyocytes directs the coordinated electrical activity and mechanical contraction of the human heart. The characteristic transmural change in cardiomyocyte orientation underlies base-to-apex shortening, circumferential shortening, and left ventricular torsion during contraction. Individual cardiomyocytes shorten ∼15% and increase in diameter ∼8%. Remarkably, however, the left ventricular wall thickens by up to 30-40%. To accommodate this, the myocardium must undergo significant structural rearrangement during contraction. At the mesoscale, collections of cardiomyocytes are organized into sheetlets, and sheetlet shear is the fundamental mechanism of rearrangement that produces wall thickening. Herein, we review the histological and physiological studies of myocardial mesostructure that have established the sheetlet shear model of wall thickening. Recent developments in tissue clearing techniques allow for imaging of whole hearts at the cellular scale, whereas magnetic resonance imaging (MRI) and computed tomography (CT) can image the myocardium at the mesoscale (100 µm to 1 mm) to resolve cardiomyocyte orientation and organization. Through histology, cardiac diffusion tensor imaging (DTI), and other modalities, mesostructural sheetlets have been confirmed in both animal and human hearts. Recent in vivo cardiac DTI methods have measured reorientation of sheetlets during the cardiac cycle. We also examine the role of pathological cardiac remodeling on sheetlet organization and reorientation, and the impact this has on ventricular function and dysfunction. We also review the unresolved mesostructural questions and challenges that may direct future work in the field.
Collapse
Affiliation(s)
- Alexander J Wilson
- Department of Radiology, Stanford University, Stanford, California
- Stanford Cardiovascular Institute, Stanford University, Stanford, California
| | - Gregory B Sands
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Ian J LeGrice
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
- Department of Physiology, University of Auckland, Auckland, New Zealand
| | - Alistair A Young
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
- Department of Biomedical Engineering, King's College London, London, United Kingdom
| | - Daniel B Ennis
- Department of Radiology, Stanford University, Stanford, California
- Veterans Administration Palo Alto Health Care System, Palo Alto, California
| |
Collapse
|
11
|
Hossain MM, Gallippi CM. Quantitative Estimation of Mechanical Anisotropy Using Acoustic Radiation Force (ARF)-Induced Peak Displacements (PD): In Silico and Experimental Demonstration. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:1468-1481. [PMID: 34995184 PMCID: PMC9208382 DOI: 10.1109/tmi.2022.3141084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Elastic degree of anisotropy (DoA) is a diagnostically relevant biomarker in muscle, kidney, breast, and other organs. Previously, elastic DoA was qualitatively assessed as the ratio of peak displacements (PD) achieved with the long-axis of a spatially asymmetric Acoustic Radiation Force Impulse (ARFI) excitation point spread function (PSF) aligned along versus across the axis of symmetry (AoS) in transversely isotropic materials. However, to better enable longitudinal and cross-sectional analyses, a quantitative measure of elastic DoA is desirable. In this study, qualitative ARFI PD ratios are converted to quantitative DoA, measured as the ratio of longitudinal over transverse shear elastic moduli, using a model empirically derived from Field II and finite element method (FEM) simulations. In silico, the median absolute percent error (MAPE) in ARFI-derived shear moduli ratio (SMR) was 1.75%, and predicted SMRs were robust to variations in transverse shear modulus, Young's moduli ratio, speed of sound, attenuation, density, and ARFI excitation PSF dimension. Further, ARFI-derived SMRs distinguished two materials when the true SMRs of the compared materials differed by as little as 10%. Experimentally, ARFI-derived SMRs linearly correlated with the corresponding ratios measured by Shear Wave Elasticity Imaging (SWEI) in excised pig skeletal muscle ( [Formula: see text], MAPE = 13%) and in pig kidney, in vivo ( [Formula: see text], MAPE = 5.3%). These results demonstrate the feasibility of using the ARFI PD to quantify elastic DoA in biological tissues.
Collapse
|
12
|
Ex Vivo Evaluation of Mechanical Anisotropic Tissues with High-Frequency Ultrasound Shear Wave Elastography. SENSORS 2022; 22:s22030978. [PMID: 35161728 PMCID: PMC8838528 DOI: 10.3390/s22030978] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Revised: 01/21/2022] [Accepted: 01/23/2022] [Indexed: 01/01/2023]
Abstract
The use of imaging devices to assess directional mechanics of tissues is highly desirable. This is because the directional mechanics depend on fiber orientation, and altered directional mechanics are closely related to the pathological status of tissues. However, measuring directional mechanics in tissues with high-stiffness is challenging due to the difficulty of generating localized displacement in these tissues using acoustic radiation force, a general method for generating displacement in ultrasound-based elastography. In addition, common ultrasound probes do not provide rotational function, which makes the measurement of directional mechanics inaccurate and unreliable. Therefore, we developed a high-frequency ultrasound mechanical wave elastography system that can accommodate a wide range of tissue stiffness and is also equipped with a motorized rotation stage for precise imaging of directional mechanics. A mechanical shaker was applied to the elastography system to measure tissues with high-stiffness. Phantom and ex vivo experiments were performed. In the phantom experiments, the lateral and axial resolution of the system were determined to be 144 μm and 168 μm, respectively. In the ex vivo experiments, we used swine heart and cartilage, both of which are considered stiff. The elastography system allows us to acquire the directional mechanics with high angular resolution in the heart and cartilage. The results demonstrate that the developed elastography system is capable of imaging a wide range of tissues and has high angular resolution. Therefore, this system might be useful for the diagnostics of mechanically anisotropic tissues via ex vivo tests.
Collapse
|
13
|
Caenen A, Pernot M, Nightingale KR, Voigt JU, Vos HJ, Segers P, D'hooge J. Assessing cardiac stiffness using ultrasound shear wave elastography. Phys Med Biol 2021; 67. [PMID: 34874312 DOI: 10.1088/1361-6560/ac404d] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 12/06/2021] [Indexed: 11/11/2022]
Abstract
Shear wave elastography offers a new dimension to echocardiography: it measures myocardial stiffness. Therefore, it could provide additional insights into the pathophysiology of cardiac diseases affecting myocardial stiffness and potentially improve diagnosis or guide patient treatment. The technique detects fast mechanical waves on the heart wall with high frame rate echography, and converts their propagation velocity into a stiffness value. A proper interpretation of shear wave data is required as the shear wave interacts with the intrinsic, yet dynamically changing geometrical and material characteristics of the heart under pressure. This dramatically alters the wave physics of the propagating wave, demanding adapted processing methods compared to other shear wave elastography applications as breast tumor and liver stiffness staging. Furthermore, several advanced analysis methods have been proposed to extract supplementary material features such as viscosity and anisotropy, potentially offering additional diagnostic value. This review explains the general mechanical concepts underlying cardiac shear wave elastography and provides an overview of the preclinical and clinical studies within the field. We also identify the mechanical and technical challenges ahead to make shear wave elastography a valuable tool for clinical practice.
Collapse
Affiliation(s)
- Annette Caenen
- Institute for Biomedical Engineering and Technology, Ghent University, Ghent, BELGIUM
| | - Mathieu Pernot
- INSERM U979 "Physics for medicine", ESPCI Paris, PSL Research University, CNRS UMR 7587, Institut Langevin, Paris, FRANCE
| | - Kathryn R Nightingale
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, UNITED STATES
| | - Jens-Uwe Voigt
- Department of Cardiovascular Sciences, KU Leuven, Leuven, BELGIUM
| | - Hendrik J Vos
- Department of Biomedical Engineering, Erasmus MC, Rotterdam, Zuid-Holland, NETHERLANDS
| | - Patrick Segers
- Institute of Biomedical Engineering and Technology, Universiteit Gent, Gent, BELGIUM
| | - Jan D'hooge
- Department of Cardiovascular Sciences, KU Leuven, Leuven, BELGIUM
| |
Collapse
|
14
|
Kovacheva E, Thämer L, Fritz T, Seemann G, Ochs M, Dössel O, Loewe A. Estimating cardiac active tension from wall motion-An inverse problem of cardiac biomechanics. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3448. [PMID: 33606343 DOI: 10.1002/cnm.3448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 12/21/2020] [Accepted: 02/06/2021] [Indexed: 06/12/2023]
Abstract
The contraction of the human heart is a complex process as a consequence of the interaction of internal and external forces. In current clinical routine, the resulting deformation can be imaged during an entire heart beat. However, the active tension development cannot be measured in vivo but may provide valuable diagnostic information. In this work, we present a novel numerical method for solving an inverse problem of cardiac biomechanics-estimating the dynamic active tension field, provided the motion of the myocardial wall is known. This ill-posed non-linear problem is solved using second order Tikhonov regularization in space and time. We conducted a sensitivity analysis by varying the fiber orientation in the range of measurement accuracy. To achieve RMSE <20% of the maximal tension, the fiber orientation needs to be provided with an accuracy of 10°. Also, variation was added to the deformation data in the range of segmentation accuracy. Here, imposing temporal regularization led to an eightfold decrease in the error down to 12%. Furthermore, non-contracting regions representing myocardial infarct scars were introduced in the left ventricle and could be identified accurately in the inverse solution (sensitivity >0.95). The results obtained with non-matching input data are promising and indicate directions for further improvement of the method. In future, this method will be extended to estimate the active tension field based on motion data from clinical images, which could provide important insights in terms of a new diagnostic tool for the identification and treatment of diseased heart tissue.
Collapse
Affiliation(s)
- Ekaterina Kovacheva
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Laura Thämer
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Thomas Fritz
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
- Department of Cardiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Gunnar Seemann
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
- Institute for Experimental Cardiovascular Medicine, University Heart Center Freiburg, Bad Krozingen, Medical Center, University of Freiburg, Freiburg, Germany
- Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Marco Ochs
- Department of Cardiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Olaf Dössel
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Axel Loewe
- Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| |
Collapse
|
15
|
Dong J, Lee WN. Noninvasive Assessment of In Vivo Passive Skeletal Muscle Mechanics as a Composite Material Using Biomedical Ultrasound. IEEE Trans Biomed Eng 2021; 69:1162-1172. [PMID: 34559632 DOI: 10.1109/tbme.2021.3115144] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE This study develops a biomedical ultrasound imaging method to infer microstructural information (i.e., tissue level) from imaging mechanical behavior of skeletal muscle (i.e., organ level). METHODS We first reviewed the constitutive model of skeletal muscle by regarding it as a transversely isotropic (TI) hyperelastic composite material, for which a theoretical formula was established among shear wave speed, deformation, and material parameters (MPs) using the acoustoelasticity theory. The formula was evaluated by finite element (FE) simulations and experimentally examined using ultrasound shear wave imaging (SWI) and strain imaging (SI) on in vivo passive biceps brachii muscles of two healthy volunteers. The imaging sequence included 1) generation of SW in multiple propagation directions while resting the muscle at an elbow angle of 90; 2) generation of SW propagating along the myofiber direction during continuous uniaxial muscle extension by passively changing the elbow angle from 90 to 120. Ultrasound-quantified SW speeds and muscle deformations were fitted by the theoretical formula to estimate MPs of in vivo passive muscle. RESULTS Estimated myofiber stiffness, stiffness ratio of myofiber to extracellular matrix (ECM), ECM volume ratio all agreed with literature findings. CONCLUSION The proposed mathematical formula together with our in-house ultrasound imaging method enabled assessing microstructural material properties of in vivo passive skeletal muscle from organ-level mechanical behavior in an entirely noninvasive way. SIGNIFICANCE Noninvasive assessment of both micro and macro properties of in vivo skeletal muscle will advance our understanding of complex muscle dynamics and facilitate treatment and rehabilitation planning.
Collapse
|
16
|
Pedreira O, Correia M, Chatelin S, Villemain O, Goudot G, Thiebaut S, Bassan G, Messas E, Tanter M, Papadacci C, Pernot M. Smart ultrasound device for non-invasive real-time myocardial stiffness quantification of the human heart. IEEE Trans Biomed Eng 2021; 69:42-52. [PMID: 34097602 DOI: 10.1109/tbme.2021.3087039] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Quantitative assessment of myocardial stiffness is crucial to understand and evaluate cardiac biomechanics and function. Despite the recent progresses of ultrasonic shear wave elastography, quantitative evaluation of myocardial stiffness still remains a challenge because of strong elastic anisotropy. In this paper we introduce a smart ultrasound approach for non-invasive real-time quantification of shear wave velocity (SWV) and elastic fractional anisotropy (FA) in locally transverse isotropic elastic medium such as the myocardium. The approach relies on a simultaneous multidirectional evaluation of the SWV without a prior knowledge of the fiber orientation. We demonstrated that it can quantify accurately SWV in the range of 1.5 to 6 m/s in transverse isotropic medium (FA<0.7) using numerical simulations. Experimental validation was performed on calibrated phantoms and anisotropic ex vivo tissues. A mean absolute error of 0.22 m/s was found when compared to gold standard measurements. Finally, in vivo feasibility of myocardial anisotropic stiffness assessment was evaluated in four healthy volunteers on the antero-septo basal segment and on anterior free wall of the right ventricle (RV) in end-diastole. A mean longitudinal SWV of 1.08 0.20 m/s was measured on the RV wall and 1.74 0.51 m/s on the Septal wall with a good intra-volunteer reproducibility (0.18 m/s). This approach has the potential to become a clinical tool for the quantitative evaluation of myocardial stiffness and diastolic function.
Collapse
|
17
|
Sichitiu J, Meuwly JY, Baud D, Desseauve D. Using shear wave elastography to assess uterine tonicity after vaginal delivery. Sci Rep 2021; 11:10420. [PMID: 34001934 PMCID: PMC8129155 DOI: 10.1038/s41598-021-89756-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 04/30/2021] [Indexed: 12/19/2022] Open
Abstract
This study aims to evaluate the feasibility and clinical interest of shear wave elastography, by quantitatively estimating the baseline stiffness of the myometrium before and after placental expulsion. We conducted a prospective cohort study of women at term, without known risk factors for postpartum hemorrhage, who gave birth via spontaneous labor in our tertiary center. Myometrium tonicity was evaluated based on measurements of shear wave speed (SWS) in the anterior uterine corpus. All data points were collected by a single operator. Measurements were carried out at three different time points: after fetal delivery (T1), after placental delivery (T2) and 30 min after placental delivery (T3). Our primary objective was to assess the feasibility of this new imaging technique. Ten valid SWS measurements obtained at each of the three different time points were considered as a positive primary outcome. Our secondary objectives were to evaluate the difference in median myometrial shear wave velocity between each time point, as well as to determine the correlation between myometrial shear wave velocity and patients’ characteristics. 38 women were recruited during the study period, of whom 34 met the study criteria. 1017 SWS measurements were obtained. The median time to perform measurements was 16 s for one value, and 2 min 56 s for ten. For 11 women (32%) it was not possible to achieve ten SWS at T1 as placental expulsion immediately followed the birth of the newborn. One patient experienced placental retention and only measurements at T1 were performed. For all other patients, we were successfully able to obtain all measures as intended. There was no difference in the mean shear wave speed between the three time points. After adjustments for confounders, we observed a significant correlation for total blood loss (correlation coefficient = − 0.26, p < 0.001, units of oxytocin (correlation coefficient = − 0.34, p = 0.03), and newborn weight (correlation coefficient = − 0.08, p = 0.001). It is feasible to assess uterine tonicity by shear wave imaging, after placental expulsion. We did not observe a variance in uterine tonicity between the three time points. Women who had higher blood loss, received more units of oxytocin and/or those with newborns of a higher weight exhibited lower shear wave speed measures.
Collapse
Affiliation(s)
- Joanna Sichitiu
- Women - Mother - Child Department, Lausanne University Hospital, Avenue Pierre Decker 2, 1011, Lausanne, Switzerland.
| | - Jean-Yves Meuwly
- Department of Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - David Baud
- Women - Mother - Child Department, Lausanne University Hospital, Avenue Pierre Decker 2, 1011, Lausanne, Switzerland
| | - David Desseauve
- Women - Mother - Child Department, Lausanne University Hospital, Avenue Pierre Decker 2, 1011, Lausanne, Switzerland
| |
Collapse
|
18
|
Besomi M, Nava GTDA, van den Hoorn W, Hug F, Vicenzino B, Hodges PW. Influence of transducer orientation on shear wave velocity measurements of the iliotibial band. J Biomech 2021; 120:110346. [PMID: 33714007 DOI: 10.1016/j.jbiomech.2021.110346] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 02/01/2021] [Accepted: 02/22/2021] [Indexed: 12/25/2022]
Abstract
Tissue anisotropy influences estimation of mechanical properties of connective tissues, such as the iliotibial band (ITB). This study investigated the influence of ultrasound transducer rotation and tilt on shear wave velocity (SWV, an index of stiffness) measurements of the ITB and the intra-rater repeatability of SWV measurements in the longitudinal direction. SWV was measured unilaterally (dominant limb) using ultrasound shear wave elastography in the middle region of the ITB in supine at rest (20-25° knee flexion) in ten healthy volunteers (4 females). A 3-dimensional video system provided real-time feedback of probe orientation with respect to the thigh. Measurements were made at 10° increments of probe rotation, from longitudinal to transverse alignment relative to the approximate direction of ITB fibres, and 5-10° tilts about the longitudinal and sideways axes of the transducer. One-way repeated measures ANOVA compared SWV between angles and tilts. Intraclass correlation coefficients (ICCs) and standard error of measurement (SEM) were used to calculate repeatability for two to five (longitudinal only) repetitions. SWV was greatest when the transducer was aligned to ITB fibres (longitudinal: 10.5 ± 1.7 m/s) and lowest when perpendicular (transverse: 5.8 ± 2.4 m/s). Compared to longitudinal alignment, SWV decreased significantly (p < 0.01) when the transducer was rotated 20° or more. Tilted measurements did not differ between angles. Intra-rater repeatability was excellent with the average of two measurements (ICC = 0.99, 95% CI 0.95, 0.99; SEM = 0.31 m/s). These findings show that SWV changes with orientation relative to fibre direction. Transducer orientation requires careful control to ensure comparable measures.
Collapse
Affiliation(s)
- Manuela Besomi
- The University of Queensland, School of Health and Rehabilitation Sciences, Brisbane, Qld 4072, Australia
| | - Guilherme Thomaz de Aquino Nava
- Department of Physical Education, Institute of Biosciences of Rio Claro, São Paulo State University (UNESP), Rio Claro, São Paulo, Brazil
| | - Wolbert van den Hoorn
- The University of Queensland, School of Health and Rehabilitation Sciences, Brisbane, Qld 4072, Australia
| | - François Hug
- The University of Queensland, School of Health and Rehabilitation Sciences, Brisbane, Qld 4072, Australia; Faculty of Sport Sciences, Laboratory "Movement, Interactions, Performance" (EA 4334), University of Nantes, Nantes, France; Institut Universitaire de France (IUF), Paris, France
| | - Bill Vicenzino
- The University of Queensland, School of Health and Rehabilitation Sciences, Brisbane, Qld 4072, Australia
| | - Paul W Hodges
- The University of Queensland, School of Health and Rehabilitation Sciences, Brisbane, Qld 4072, Australia.
| |
Collapse
|
19
|
Kari M, Feltovich H, Hall TJ. Correlation length ratio as a parameter for determination of fiber-like structures in soft tissues. Phys Med Biol 2021; 66:055017. [PMID: 33508818 PMCID: PMC8335944 DOI: 10.1088/1361-6560/abe0fb] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Quantitative ultrasound methods can provide valuable information about the microstructure of a material or tissue. This works well when the common assumptions of homogeneity, isotropy, and diffuse scattering conditions are valid. In biological tissues, however, these assumptions are often violated because the microstructure of biological tissues is often heterogeneous and anisotropic. The microstructure of biological tissues can change with disease, and therefore accurate identification and description of a tissue's microstructure can offer important clinical insight. To address the challenge of evaluating the microstructure of biological tissues, here we introduce a novel parameter called the correlation length ratio (CLR), a ratio of lateral to axial correlation lengths for backscattered echo signals. We developed it to determine the presence of fiber-like structures in soft tissues by comparing this value in tissue to a threshold determined from a reference material that is homogeneous, isotropic, and provides diffuse scattering. We tested this novel parameter in phantoms with spherical scattering sources, in an anisotropic phantom (containing elongated fibers), and in human biceps muscle. We found that the CLR accurately detected the presence of elongated structures in both the anisotropic phantom and muscle. These results encourage further exploration of this novel parameter in microstructurally complex tissues.
Collapse
Affiliation(s)
- M Kari
- Medical Physics, University of Wisconsin-Madison, Madison, WI, United States of America
| | - H Feltovich
- Maternal Fetal Medicine, Intermountain Healthcare, Provo, UT, United States of America
| | - T J Hall
- Medical Physics, University of Wisconsin-Madison, Madison, WI, United States of America
| |
Collapse
|
20
|
Petrescu A, D'hooge J, Voigt JU. Concepts and applications of ultrafast cardiac ultrasound imaging. Echocardiography 2021; 38:7-15. [PMID: 33471395 DOI: 10.1111/echo.14971] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 12/22/2020] [Indexed: 12/20/2022] Open
Abstract
The concept of ultrafast echocardiographic imaging has been around for decades. However, only recent progress in ultrasound machine hardware and computer technology allowed to apply this concept to echocardiography. High frame rate echocardiography can visualize phenomena that have never been captured before. It enables a wide variety of potential new applications, including shear wave imaging, speckle tracking, ultrafast Doppler imaging, and myocardial perfusion imaging. The principles of these applications and their potential clinical use will be presented in this manuscript.
Collapse
Affiliation(s)
- Aniela Petrescu
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.,Department of Cardiology, Heart Valve Center, University Medical Center Mainz, Mainz, Germany
| | - Jan D'hooge
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium
| | - Jens-Uwe Voigt
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.,Department of Cardiovascular Diseases, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|
21
|
Nitta N, Yamakawa M, Hachiya H, Shiina T. A review of physical and engineering factors potentially affecting shear wave elastography. J Med Ultrason (2001) 2021; 48:403-414. [PMID: 34453649 PMCID: PMC8578095 DOI: 10.1007/s10396-021-01127-w] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Accepted: 07/15/2021] [Indexed: 01/01/2023]
Abstract
It has been recognized that tissue stiffness provides useful diagnostic information, as with palpation as a screening for diseases such as cancer. In recent years, shear wave elastography (SWE), a technique for evaluating and imaging tissue elasticity quantitatively and objectively in diagnostic imaging, has been put into practical use, and the amount of clinical knowledge about SWE has increased. In addition, some guidelines and review papers regarding technology and clinical applications have been published, and the status as a diagnostic technology is in the process of being established. However, there are still unclear points about the interpretation of shear wave speed (SWS) and converted elastic modulus in SWE. To clarify these, it is important to investigate the factors that affect the SWS and elastic modulus. Therefore, physical and engineering factors that potentially affect the SWS and elastic modulus are discussed in this review paper, based on the principles of SWE and a literature review. The physical factors include the propagation properties of shear waves, mechanical properties (viscoelasticity, nonlinearity, and anisotropy), and size and shape of target tissues. The engineering factors include the region of interest depth and signal processing. The aim of this review paper is not to provide an answer to the interpretation of SWS. It is to provide information for readers to formulate and verify the hypothesis for the interpretation. Therefore, methods to verify the hypothesis for the interpretation are also reviewed. Finally, studies on the safety of SWE are discussed.
Collapse
Affiliation(s)
- Naotaka Nitta
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki, 305-8564, Japan.
| | - Makoto Yamakawa
- Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Hiroyuki Hachiya
- School of Engineering, Tokyo Institute of Technology, Meguro, Tokyo, 152-8552, Japan
| | - Tsuyoshi Shiina
- Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| |
Collapse
|
22
|
Papadacci C, Finel V, Villemain O, Tanter M, Pernot M. 4D Ultrafast Ultrasound Imaging of Naturally Occurring Shear Waves in the Human Heart. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:4436-4444. [PMID: 32857692 DOI: 10.1109/tmi.2020.3020147] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The objectives were to develop a novel three-dimensional technology for imaging naturally occurring shear wave (SW) propagation, demonstrate feasibility on human volunteers and quantify SW velocity in different propagation directions. Imaging of natural SWs generated by valve closures has emerged to obtain a direct measurement of cardiac stiffness. Recently, natural SW velocity was assessed in two dimensions on parasternal long axis view under the assumption of a propagation direction along the septum. However, in this approach the source localization and the complex three-dimensional propagation wave path was neglected making the speed estimation unreliable. High volume rate transthoracic acquisitions of the human left ventricle (1100 volume/s) was performed with a 4D ultrafast echocardiographic scanner. Four-dimensional tissue velocity cineloops enabled visualization of aortic and mitral valve closure waves. Energy and time of flight mapping allowed propagation path visualization and source localization, respectively. Velocities were quantified along different directions. Aortic and mitral valve closure SW velocities were assessed for the three volunteers with low standard deviation. Anisotropic propagation was also found suggesting the necessity of using a three-dimensional imaging approach. Different velocities were estimated for the three directions for the aortic (3.4± 0.1 m/s, 3.5± 0.3 m/s, 5.4± 0.7 m/s) and the mitral (2.8± 0.5 m/s, 2.9± 0.3 m/s, 4.6± 0.7 m/s) valve SWs. 4D ultrafast ultrasound alleviates the limitations of 2D ultrafast ultrasound for cardiac SW imaging based on natural SW propagations and enables a comprehensive measurement of cardiac stiffness. This technique could provide stiffness mapping of the left ventricle.
Collapse
|
23
|
Agger P, Stephenson RS. Assessing Myocardial Architecture: The Challenges and Controversies. J Cardiovasc Dev Dis 2020; 7:jcdd7040047. [PMID: 33137874 PMCID: PMC7711767 DOI: 10.3390/jcdd7040047] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 10/04/2020] [Accepted: 10/08/2020] [Indexed: 12/16/2022] Open
Abstract
In recent decades, investigators have strived to describe and quantify the orientation of the cardiac myocytes in an attempt to classify their arrangement in healthy and diseased hearts. There are, however, striking differences between the investigations from both a technical and methodological standpoint, thus limiting their comparability and impeding the drawing of appropriate physiological conclusions from the structural assessments. This review aims to elucidate these differences, and to propose guidance to establish methodological consensus in the field. The review outlines the theory behind myocyte orientation analysis, and importantly has identified pronounced differences in the definitions of otherwise widely accepted concepts of myocytic orientation. Based on the findings, recommendations are made for the future design of studies in the field of myocardial morphology. It is emphasised that projection of myocyte orientations, before quantification of their angulation, introduces considerable bias, and that angles should be assessed relative to the epicardial curvature. The transmural orientation of the cardiomyocytes should also not be neglected, as it is an important determinant of cardiac function. Finally, there is considerable disagreement in the literature as to how the orientation of myocardial aggregates should be assessed, but to do so in a mathematically meaningful way, the normal vector of the aggregate plane should be utilised.
Collapse
Affiliation(s)
- Peter Agger
- Comparative Medicine Lab, Department of Clinical Medicine, Aarhus University, 8220 Aarhus N, Denmark
- Department of Pediatrics, Randers Regional Hospital, Skovlyvej 15, 8930 Randers NE, Denmark
- Correspondence:
| | - Robert S. Stephenson
- Institute of Clinical Sciences, College of Medical and Dental Sciences, University of Birmingham, Birmingham B15 2TT, UK;
| |
Collapse
|
24
|
Dejea H, Bonnin A, Cook AC, Garcia-Canadilla P. Cardiac multi-scale investigation of the right and left ventricle ex vivo: a review. Cardiovasc Diagn Ther 2020; 10:1701-1717. [PMID: 33224784 DOI: 10.21037/cdt-20-269] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The heart is a complex multi-scale system composed of components integrated at the subcellular, cellular, tissue and organ levels. The myocytes, the contractile elements of the heart, form a complex three-dimensional (3D) network which enables propagation of the electrical signal that triggers the contraction to efficiently pump blood towards the whole body. Cardiovascular diseases (CVDs), a major cause of mortality in developed countries, often lead to cardiovascular remodeling affecting cardiac structure and function at all scales, from myocytes and their surrounding collagen matrix to the 3D organization of the whole heart. As yet, there is no consensus as to how the myocytes are arranged and packed within their connective tissue matrix, nor how best to image them at multiple scales. Cardiovascular imaging is routinely used to investigate cardiac structure and function as well as for the evaluation of cardiac remodeling in CVDs. For a complete understanding of the relationship between structural remodeling and cardiac dysfunction in CVDs, multi-scale imaging approaches are necessary to achieve a detailed description of ventricular architecture along with cardiac function. In this context, ventricular architecture has been extensively studied using a wide variety of imaging techniques: ultrasound (US), optical coherence tomography (OCT), microscopy (confocal, episcopic, light sheet, polarized light), magnetic resonance imaging (MRI), micro-computed tomography (micro-CT) and, more recently, synchrotron X-ray phase contrast imaging (SR X-PCI). Each of these techniques have their own set of strengths and weaknesses, relating to sample size, preparation, resolution, 2D/3D capabilities, use of contrast agents and possibility of performing together with in vivo studies. Therefore, the combination of different imaging techniques to investigate the same sample, thus taking advantage of the strengths of each method, could help us to extract the maximum information about ventricular architecture and function. In this review, we provide an overview of available and emerging cardiovascular imaging techniques for assessing myocardial architecture ex vivo and discuss their utility in being able to quantify cardiac remodeling, in CVDs, from myocyte to whole organ.
Collapse
Affiliation(s)
- Hector Dejea
- Paul Scherrer Institut, Villigen PSI, Villigen, Switzerland.,Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Anne Bonnin
- Paul Scherrer Institut, Villigen PSI, Villigen, Switzerland
| | - Andrew C Cook
- Institute of Cardiovascular Science, University College London, London, UK
| | - Patricia Garcia-Canadilla
- Institute of Cardiovascular Science, University College London, London, UK.,Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| |
Collapse
|
25
|
Keijzer LBH, Strachinaru M, Bowen DJ, Caenen A, van Steen AFWD, Verweij MD, de Jong N, Bosch JG, Vos HJ. Parasternal Versus Apical View in Cardiac Natural Mechanical Wave Speed Measurements. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:1590-1602. [PMID: 32149686 DOI: 10.1109/tuffc.2020.2978299] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Shear wave speed measurements can potentially be used to noninvasively measure myocardial stiffness to assess the myocardial function. Several studies showed the feasibility of tracking natural mechanical waves induced by aortic valve closure in the interventricular septum, but different echocardiographic views have been used. This article systematically studied the wave propagation speeds measured in a parasternal long-axis and in an apical four-chamber view in ten healthy volunteers. The apical and parasternal views are predominantly sensitive to longitudinal or transversal tissue motion, respectively, and could, therefore, theoretically measure the speed of different wave modes. We found higher propagation speeds in apical than in the parasternal view (median of 5.1 m/s versus 3.8 m/s, , n = 9 ). The results in the different views were not correlated ( r = 0.26 , p = 0.49 ) and an unexpectedly large variability among healthy volunteers was found in apical view compared with the parasternal view (3.5-8.7 versus 3.2-4.3 m/s, respectively). Complementary finite element simulations of Lamb waves in an elastic plate showed that different propagation speeds can be measured for different particle motion components when different wave modes are induced simultaneously. The in vivo results cannot be fully explained with the theory of Lamb wave modes. Nonetheless, the results suggest that the parasternal long-axis view is a more suitable candidate for clinical diagnosis due to the lower variability in wave speeds.
Collapse
|
26
|
Villemain O, Baranger J, Friedberg MK, Papadacci C, Dizeux A, Messas E, Tanter M, Pernot M, Mertens L. Ultrafast Ultrasound Imaging in Pediatric and Adult Cardiology. JACC Cardiovasc Imaging 2020; 13:1771-1791. [DOI: 10.1016/j.jcmg.2019.09.019] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 08/29/2019] [Accepted: 09/03/2019] [Indexed: 02/08/2023]
|
27
|
Cheung WK, Cheung JPY, Lee WN. Role of Ultrasound in Low Back Pain: A Review. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1344-1358. [PMID: 32192782 DOI: 10.1016/j.ultrasmedbio.2020.02.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 01/27/2020] [Accepted: 02/04/2020] [Indexed: 06/10/2023]
Abstract
Low back pain is one of most common musculoskeletal disorders around the world. One major problem clinicians face is the lack of objective assessment modalities. Computed tomography and magnetic resonance imaging are commonly utilized but are unable to clearly distinguish patients with low back pain from healthy patients with respect to abnormalities. The reason may be the anisotropic nature of muscles, which is altered in function, and the scans provide only structural assessment. In view of this, ultrasound may be helpful in understanding the disease as it is performed in real-time and comprises different modes that measure thickness, blood flow and stiffness. By the use of ultrasound, patients with low back pain have been found to differ from healthy patients with respect to the thickness and stiffness of the transversus abdominis, thoracolumbar fascia and multifidus. The study results are currently still not conclusive, and further study is necessary to validate. Future work should focus on quantitative assessment of these tissues to provide textural, structural, hemodynamic and mechanical studies of low back pain. This review highlights the current understanding of how medical ultrasound has been used for diagnosis and study of low back pain and discusses potential new applications.
Collapse
Affiliation(s)
- Wing Ki Cheung
- Department of Orthopaedics and Traumatology, University of Hong Kong, Pokfulam, SAR, China
| | - Jason Pui Yin Cheung
- Department of Orthopaedics and Traumatology, University of Hong Kong, Pokfulam, SAR, China.
| | - Wei-Ning Lee
- Department of Electrical and Electronic Engineering, Biomedical Engineering Programme, University of Hong Kong, Pokfulam, SAR, China
| |
Collapse
|
28
|
Dong J, Zhang Y, Lee WN. Walled vessel-mimicking phantom for ultrasound imaging using 3D printing with a water-soluble filament: design principle, fluid-structure interaction (FSI) simulation, and experimental validation. Phys Med Biol 2020; 65:085006. [PMID: 32106096 DOI: 10.1088/1361-6560/ab7abf] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
The geometry and stiffness of a vessel are pertinent to blood dynamics and vessel wall mechanical behavior and may alter in diseased conditions. Ultrasound-based ultrafast Doppler (uDoppler) imaging and shear wave imaging (SWI) techniques have been extensively exploited for the assessment of vascular hemodynamics and mechanics. Their performance is conventionally validated on vessel-mimicking phantoms (VMPs) prior to their clinical use. Compared with commercial ones, customized VMPs are favored for research use because of their wider range of material properties, more complex lumen geometries, or wall structures. Fused deposition modeling (FDM) 3D printing technique with plastic filaments is a promising method for making VMPs with a complex vessel lumen. However, it may require a toxic solvent or a long dissolution time currently. In this paper, we present a safe, efficient and geometrically flexible method where FDM 3D printing with a water-soluble polyvinyl alcohol (PVA) filament is exploited to fabricate a walled three-branch VMP (VMP-I). As a key step in fabrication, to avoid dissolution of the PVA-printed vessel core by the solution of the tissue-mimicking material, paraffin wax was used for isolation. Paraffin wax is easy to coat (i.e. without any special equipment), of satisfactory thickness (∼0.1 mm), chemically stable, and easy to remove after fabrication, thus making the proposed method practicable for ultrasound imaging studies. VMP-I was examined by B-mode imaging and power Doppler imaging (PDI) to verify complete dissolution of PVA-printed vessel core in its lumen, confirming good fabrication quality. The flow velocities in VMP-I were estimated by uDoppler imaging with a -0.8% difference, and the shear wave propagation speeds for the same phantom were estimated by SWI with a -6.03% difference when compared with fluid-structure interaction (FSI) simulation results. A wall-less VMP of a scaled and simplified coronary arterial network (VMP-II) was additionally fabricated and examined to test the capability of the proposed method for a complex lumen geometry. The proposed fabrication method for customized VMPs is foreseen to facilitate the development of ultrasound imaging techniques for blood vessels.
Collapse
Affiliation(s)
- Jinping Dong
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong
| | | | | |
Collapse
|
29
|
Milne ML, Schick BM, Alkhazal T, Chung CS. Myocardial Fiber Mapping of Rat Hearts, Using Apparent Backscatter, with Histologic Validation. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2075-2085. [PMID: 31155403 PMCID: PMC6615029 DOI: 10.1016/j.ultrasmedbio.2019.05.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Revised: 03/26/2019] [Accepted: 05/06/2019] [Indexed: 06/09/2023]
Abstract
Myocardial fiber architecture is a physiologically important regulator of ejection fraction, strain and pressure development. Apparent ultrasonic backscatter has been shown to be a useful method for recreating the myocardial fiber architecture in human-sized sheep hearts because of the dependence of its amplitude on the relative orientation of a myofiber to the angle of ultrasonic insonification. Thus, the anisotropy of the backscatter signal is linked to and provides information about the fiber orientation. In this study, we sought to determine whether apparent backscatter could be used to measure myofiber orientation in rodent hearts. Fixed adult-rat hearts were imaged intact, and both a transmural cylindrical core and transmural wedge of the left ventricular free wall were imaged. Cylindrical core samples confirmed that backscatter anisotropy could be measured in rat hearts. Ultrasound and histologic analysis of transmural myocardial wedge samples confirmed that the apparent backscatter could be reproducibly mapped to fiber orientation (angle of the fiber relative to the direction of insonification). These data provided a quantitative relationship between the apparent backscatter and fiber angle that was applied to whole-heart images. Myocardial fiber architecture was successfully measured in rat hearts. Quantifying myocardial fiber architecture, using apparent backscatter, provides a number of advantages, including its scalable use from rodents to man, its rapid low-cost acquisition and minimal contraindications. The method outlined in this study provides a method for investigators to begin detailed assessments of how the myocardial fiber architecture changes in preclinical disease models, which can be immediately translated into the clinic.
Collapse
Affiliation(s)
- Michelle L Milne
- Department of Physics, St. Mary's College of Maryland, St. Mary's City, MD, USA
| | - Brianna M Schick
- Department of Physiology, Wayne State University, Detroit, MI, USA
| | - Thamer Alkhazal
- Department of Physiology, Wayne State University, Detroit, MI, USA
| | - Charles S Chung
- Department of Physiology, Wayne State University, Detroit, MI, USA.
| |
Collapse
|
30
|
McLean JP, Gan Y, Lye TH, Qu D, Lu HH, Hendon CP. High-speed collagen fiber modeling and orientation quantification for optical coherence tomography imaging. OPTICS EXPRESS 2019; 27:14457-14471. [PMID: 31163895 PMCID: PMC6825605 DOI: 10.1364/oe.27.014457] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 04/18/2019] [Accepted: 04/24/2019] [Indexed: 05/03/2023]
Abstract
Quantifying collagen fiber architecture has clinical and scientific relevance across a variety of tissue types and adds functionality to otherwise largely qualitative imaging modalities. Optical coherence tomography (OCT) is uniquely suited for this task due to its ability to capture the collagen microstructure over larger fields of view than traditional microscopy. Existing image processing techniques for quantifying fiber architecture, while accurate and effective, are very slow for processing large datasets and tend to lack structural specificity. We describe here a computationally efficient method for quantifying and visualizing collagen fiber organization. The algorithm is demonstrated on swine atria, bovine anterior cruciate ligament, and human cervical tissue samples. Additionally, we show an improved performance for images with crimped fiber textures and low signal to noise when compared to similar methods.
Collapse
Affiliation(s)
- James P. McLean
- Electrical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 1300 West 120th Street, New York, NY 10025,
USA
| | - Yu Gan
- Electrical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 1300 West 120th Street, New York, NY 10025,
USA
| | - Theresa H. Lye
- Electrical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 1300 West 120th Street, New York, NY 10025,
USA
| | - Dovina Qu
- Biomedical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 1300 West 120th Street, New York, NY 10025,
USA
| | - Helen H. Lu
- Biomedical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 1300 West 120th Street, New York, NY 10025,
USA
| | - Christine P. Hendon
- Electrical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, 1300 West 120th Street, New York, NY 10025,
USA
| |
Collapse
|
31
|
Vejdani-Jahromi M, Freedman J, Trahey GE, Wolf PD. Measuring Intraventricular Pressure Using Ultrasound Elastography. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:1167-1177. [PMID: 30218456 DOI: 10.1002/jum.14795] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 07/13/2018] [Accepted: 07/23/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVES Intraventricular pressure (IVP) is one of the most important measurements for evaluating cardiac function, but this measurement is not currently easily assessable in the clinic. The primary reason for this is the absence of a noninvasive technique for measuring IVP. In this study, we investigate the relationship between IVP and dynamic myocardial stiffness measured by shear wave elasticity imaging (SWEI) and assess the feasibility of measuring IVP using SWEI. METHODS In 8 isolated working rabbit hearts, IVP was recorded in the left ventricle using a pressure catheter. Simultaneously, myocardial stiffness was recorded by SWEI. Using the peak values for IVP and SWEI measured stiffness, SWEI measurements were calibrated and converted to IVP. RESULTS A linear relationship with zero intercept was observed between IVP and SWEI, with the average slope of 0.318 kPa/mm Hg, R2 = 0.89. Using one point on the IVP/SWEI curve, SWEI measurements were converted to IVP. Estimated pressure using SWEI and IVP were linearly correlated with the slope of 0.95, R2 = 0.88 (mean end diastolic pressure by pressure catheter = 12.716 mm Hg and by SWEI=14.726 mm Hg), indicating the near equivalence of the 2 measurements. CONCLUSION We have shown that SWEI measurements are linearly related to IVP; therefore, pressure-based indices could potentially be derived from SWEI ultrasound elastography. The feasibility of using SWEI to estimate IVP with a single point calibration was also shown in this study.
Collapse
Affiliation(s)
| | - Jenna Freedman
- Biomedical Engineering Department, Duke University, Durham, North Carolina, USA
| | - Gregg E Trahey
- Biomedical Engineering Department, Duke University, Durham, North Carolina, USA
| | - Patrick D Wolf
- Biomedical Engineering Department, Duke University, Durham, North Carolina, USA
| |
Collapse
|
32
|
Gkontra P, El‐Bouri WK, Norton K, Santos A, Popel AS, Payne SJ, Arroyo AG. Dynamic Changes in Microvascular Flow Conductivity and Perfusion After Myocardial Infarction Shown by Image-Based Modeling. J Am Heart Assoc 2019; 8:e011058. [PMID: 30897998 PMCID: PMC6509718 DOI: 10.1161/jaha.118.011058] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Accepted: 02/19/2019] [Indexed: 12/26/2022]
Abstract
Background Microcirculation is a decisive factor in tissue reperfusion inadequacy following myocardial infarction ( MI ). Nonetheless, experimental assessment of blood flow in microcirculation remains a bottleneck. We sought to model blood flow properties in coronary microcirculation at different time points after MI and to compare them with healthy conditions to obtain insights into alterations in cardiac tissue perfusion. Methods and Results We developed an image-based modeling framework that permitted feeding a continuum flow model with anatomical data previously obtained from the pig coronary microvasculature to calculate physiologically meaningful permeability tensors. The tensors encompassed the microvascular conductivity and were also used to estimate the arteriole-venule drop in pressure and myocardial blood flow. Our results indicate that the tensors increased in a bimodal pattern at infarcted areas on days 1 and 7 after MI while a nonphysiological decrease in arteriole-venule drop in pressure was observed; contrary, the tensors and the arteriole-venule drop in pressure on day 3 after MI , and in remote areas, were closer to values for healthy tissue. Myocardial blood flow calculated using the condition-dependent arteriole-venule drop in pressure decreased in infarcted areas. Last, we simulated specific modes of vascular remodeling, such as vasodilation, vasoconstriction, or pruning, and quantified their distinct impact on microvascular conductivity. Conclusions Our study unravels time- and region-dependent alterations of tissue perfusion related to the structural changes occurring in the coronary microvasculature due to MI . It also paves the way for conducting simulations in new therapeutic interventions in MI and for image-based microvascular modeling by applying continuum flow models in other biomedical scenarios.
Collapse
Affiliation(s)
- Polyxeni Gkontra
- Centro Nacional de Investigaciones Cardiovasculares (CNIC)MadridSpain
- Biomedical Image Technologies (BIT), ETSI Telecomunicación,Universidad Politécnica de MadridMadridSpain
| | - Wahbi K. El‐Bouri
- Institute of Biomedical EngineeringDepartment of Engineering ScienceUniversity of OxfordUnited Kingdom
| | - Kerri‐Ann Norton
- Division of Science, Mathematics, and ComputingBard CollegeAnnandale‐on‐HudsonNY
| | - Andrés Santos
- Biomedical Image Technologies (BIT), ETSI Telecomunicación,Universidad Politécnica de MadridMadridSpain
- Centro de Investigación Biomédica en Red de BioingenieríaBiomateriales y Nanomedicina (CIBERBBN)MadridSpain
| | - Aleksander S. Popel
- Department of Biomedical EngineeringSchool of MedicineJohns Hopkins UniversityBaltimoreMD
| | - Stephen J. Payne
- Institute of Biomedical EngineeringDepartment of Engineering ScienceUniversity of OxfordUnited Kingdom
| | - Alicia G. Arroyo
- Centro Nacional de Investigaciones Cardiovasculares (CNIC)MadridSpain
- Centro de Investigaciones Biológicas (CIB‐CSIC)MadridSpain
| |
Collapse
|
33
|
Carbente RP, Maia JM, Assef AA. Image reconstruction utilizing median filtering applied to elastography. Biomed Eng Online 2019; 18:22. [PMID: 30866955 PMCID: PMC6417019 DOI: 10.1186/s12938-019-0641-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Accepted: 03/06/2019] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND The resources of ultrafast technology can be used to add another analysis to ultrasound imaging: assessment of tissue viscoelasticity. Ultrafast image formation can be utilized to find transitory shear waves propagating in soft tissue, which permits quantification of the mechanical properties of the tissue via elastography. This technique permits simple and noninvasive diagnosis and monitoring of disease. METHODS This article presents a method to estimate the viscoelastic properties and rigidity of structures using the ultrasound technique known as shear wave elasticity imaging (SWEI). The Verasonics Vantage 128 research platform and L11-4v transducer were used to acquire radio frequency signals from a model 049A elastography phantom (CIRS, USA), with subsequent processing and analysis in MATLAB. RESULTS The images and indexes obtained reflect the qualitative measurements of the different regions of inclusions in the phantom and the respective alterations in the viscoelastic properties of distinct areas. Comparison of the results obtained with this proposed technique and other commonly used techniques demonstrates the characteristics of median filtering in smoothing variations in velocity to form elastographic images. The results from the technique proposed in this study are within the margins of error indicated by the phantom manufacturer for each type of inclusion; for the phantom base and for type I, II, III, and IV inclusions, respectively, in kPa and percentage errors, these are 25 (24.0%), 8 (37.5%), 14 (28.6%), 45 (17.8%), and 80 (15.0%). The values obtained using the method proposed in this study and mean percentage errors were 29.18 (- 16.7%), 10.26 (- 28.2%), 15.64 (- 11.7%), 45.81 (- 1.8%), and 85.21 (- 6.5%), respectively. CONCLUSIONS The new technique to obtain images uses a distinct filtering function which considers the mean velocity in the region around each pixel, in turn allowing adjustments according to the characteristics of the phantom inclusions within the ultrasound and optimizing the resulting elastographic images.
Collapse
Affiliation(s)
- Rubem P Carbente
- Electrical Engineering Department and the Graduate School of Electrical Engineering (DAELT), Federal University of Technology-Paraná (UTFPR), Curitiba, PR, Brazil.
| | - Joaquim M Maia
- Electrical/Electronic Engineering Department and the Graduate School of Electrical Engineering and Applied Computer Sciences (DAELT-DAELN-CPGEI), Federal University of Technology-Paraná (UTFPR), Curitiba, PR, Brazil
| | - Amauri A Assef
- Electrical/Electronic Engineering Department and the Graduate School of Electrical Engineering and Applied Computer Sciences (DAELT-DAELN-CPGEI), Federal University of Technology-Paraná (UTFPR), Curitiba, PR, Brazil
| |
Collapse
|
34
|
Abstract
There has been an increasing interest in studying cardiac fibers in order to improve the current knowledge regarding the mechanical and physiological properties of the heart during heart failure (HF), particularly early HF. Having a thorough understanding of the changes in cardiac fiber orientation may provide new insight into the mechanisms behind the progression of left ventricular (LV) remodeling and HF. We conducted a systematic review on various technologies for imaging cardiac fibers and its link to HF. This review covers literature reports from 1900 to 2017. PubMed and Google Scholar databases were searched using the keywords "cardiac fiber" and "heart failure" or "myofiber" and "heart failure." This review highlights imaging methodologies, including magnetic resonance diffusion tensor imaging (MR-DTI), ultrasound, and other imaging technologies as well as their potential applications in basic and translational research on the development and progression of HF. MR-DTI and ultrasound have been most useful and significant in evaluating cardiac fibers and HF. New imaging technologies that have the ability to measure cardiac fiber orientations and identify structural and functional information of the heart will advance basic research and clinical diagnoses of HF.
Collapse
Affiliation(s)
- Shana R Watson
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - James D Dormer
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - Baowei Fei
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA. .,Winship Cancer Institute of Emory University, Atlanta, GA, USA. .,Department of Mathematics and Computer Science, Emory University, Atlanta, GA, USA. .,Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, GA, USA. .,Quantitative Bioimaging Laboratory, Department of Radiology and Imaging Sciences, School of Medicine, Emory University, Atlanta, United States.
| |
Collapse
|
35
|
Lee WN, Chang EJH, Guo Y, Wang Y. Experimental Investigation of Guided Wave Imaging in Thin Soft Media under Various Coupling Conditions. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:2821-2837. [PMID: 30241727 DOI: 10.1016/j.ultrasmedbio.2018.07.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 06/30/2018] [Accepted: 07/28/2018] [Indexed: 06/08/2023]
Abstract
Guided wave imaging for the artery remains in its infancy in clinical practice mainly because of complex arterial microstructure, hemodynamics and boundary conditions. Despite the theoretically known potential effect of the surrounding medium on guided wave propagation in thin media in non-destructive testing, experimental evidence pertaining to thin soft materials, such as the artery, is relatively scarce in the relevant literature. Therefore, this study first evaluated the propagating guided wave generated by acoustic radiation force in polyvinyl alcohol-based hydrogel plates differing in thickness and stiffness under various material coupling conditions (water and polyvinyl alcohol bulk). A thin-walled polyvinyl alcohol hollow cylindrical phantom coupled by softer gelatin-agar phantoms and an excised porcine aorta surrounded by water and pork belly were further examined. Guided waves in the thin structure and shear waves in the bulk media were captured by ultrafast ultrasound imaging, and guided wave dispersion as a function of the frequency-thickness product was analyzed using the zero-order anti-symmetric Lamb wave model to estimate the shear modulus of each thin medium studied. Results confirmed the deviated shear modulus estimates from the ground truth for thin plates, the thin-walled hollow cylindrical phantom and the porcine aorta bounded by stiffness-unmatched bulk medium. The findings indicated the need for (i) careful interpretation of estimated shear moduli of thin structure bounded by bulk media and (ii) a generalized guided wave model that takes into account the effect of coupling medium.
Collapse
Affiliation(s)
- Wei-Ning Lee
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Medical Engineering Programme, The University of Hong Kong, Hong Kong.
| | - Enoch Jing-Han Chang
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Medical Engineering Programme, The University of Hong Kong, Hong Kong
| | - Yuexin Guo
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong
| | - Yahua Wang
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong
| |
Collapse
|
36
|
Urban M. Current and Future Clinical Applications of Elasticity Imaging Techniques. ULTRASOUND ELASTOGRAPHY FOR BIOMEDICAL APPLICATIONS AND MEDICINE 2018:471-491. [DOI: 10.1002/9781119021520.ch30] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
37
|
Urban MW. Production of acoustic radiation force using ultrasound: methods and applications. Expert Rev Med Devices 2018; 15:819-834. [PMID: 30350736 DOI: 10.1080/17434440.2018.1538782] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
INTRODUCTION Acoustic radiation force (ARF) is used in many biomedical applications. The transfer of momentum in acoustic waves can be used in a multitude of ways to perturb tissue and manipulate cells. AREAS COVERED This review will briefly cover the acoustic theory related to ARF, particularly that related to application in tissues. The use of ARF in measurement of mechanical properties will be treated in detail with emphasis on the spatial and temporal modulation of the ARF. Additional topics covered will be the manipulation of particles with ARF, correction of phase aberration with ARF, modulation of cellular behavior with ARF, and bioeffects related to ARF use. EXPERT COMMENTARY The use of ARF can be tailored to specific applications for measurements of mechanical properties or correction of focusing for ultrasound beams. Additionally, noncontact manipulation of particles and cells with ARF enables a wide array of applications for tissue engineering and biosensing.
Collapse
Affiliation(s)
- Matthew W Urban
- a Department of Radiology , Mayo Clinic , Rochester , MN , USA
| |
Collapse
|
38
|
Chen Y, D'hooge J, Luo J. Doppler-Based Motion Compensation Strategies for 3-D Diverging Wave Compounding and Multiplane-Transmit Beamforming: A Simulation Study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:1631-1642. [PMID: 29994703 DOI: 10.1109/tuffc.2018.2851310] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Fast imaging of the heart has shown promise toward bringing new diagnostic information. Although most studies to date have been based on 2-D imaging technology, the ultimate diagnostic tool would enable fast 3-D echocardiography. Hereto, 3-D diverging wave compounding (DWC) and 3-D multiline-transmit (MLT) beamforming have recently been proposed. Moreover, in our recent study, a hybrid technique was proposed in which multiple planar diverging waves were transmitted [i.e., multiplane-transmit (MPT)]. The proposed 3MPT sequence was demonstrated to outperform $9 \times 9$ DWC and 16MLT-4MLA (i.e., multiline acquisition) while imaging moving targets. However, none of the investigated beamforming techniques made use of motion compensation (MoCo) strategies. In this paper, we therefore propose Doppler-based MoCo strategies for 3-D DWC and MPT and test them via computer simulations. It is demonstrated that the MoCo strategies proposed for both DWC and MPT are effective and significantly restore image quality. Moreover, the MPT beamforming with MoCo outperforms $9 \times 9$ DWC with MoCo in terms of contrast ratio and contrast-to-noise ratio. The proposed MPT beamforming with MoCo thus provides volumetric images with relatively high temporal resolution (~66 Hz) and high image quality that is minimally affected by motion artifacts.
Collapse
|
39
|
Hansen KJ, Laflamme MA, Gaudette GR. Development of a Contractile Cardiac Fiber From Pluripotent Stem Cell Derived Cardiomyocytes. Front Cardiovasc Med 2018; 5:52. [PMID: 29942806 PMCID: PMC6004416 DOI: 10.3389/fcvm.2018.00052] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2017] [Accepted: 05/04/2018] [Indexed: 01/25/2023] Open
Abstract
Stem cell therapy has the potential to regenerate cardiac function after myocardial infarction. In this study, we sought to examine if fibrin microthread technology could be leveraged to develop a contractile fiber from human pluripotent stem cell derived cardiomyocytes (hPS-CM). hPS-CM seeded onto fibrin microthreads were able to adhere to the microthread and began to contract seven days after initial seeding. A digital speckle tracking algorithm was applied to high speed video data (>60 fps) to determine contraction behaviour including beat frequency, average and maximum contractile strain, and the principal angle of contraction of hPS-CM contracting on the microthreads over 21 days. At day 7, cells seeded on tissue culture plastic beat at 0.83 ± 0.25 beats/sec with an average contractile strain of 4.23±0.23%, which was significantly different from a beat frequency of 1.11 ± 0.45 beats/sec and an average contractile strain of 3.08±0.19% at day 21 (n = 18, p < 0.05). hPS-CM seeded on microthreads beat at 0.84 ± 0.15 beats/sec with an average contractile strain of 3.56±0.22%, which significantly increased to 1.03 ± 0.19 beats/sec and 4.47±0.29%, respectively, at 21 days (n = 18, p < 0.05). At day 7, 27% of the cells had a principle angle of contraction within 20 degrees of the microthread, whereas at day 21, 65% of hPS-CM were contracting within 20 degrees of the microthread (n = 17). Utilizing high speed calcium transient data (>300 fps) of Fluo-4AM loaded hPS-CM seeded microthreads, conduction velocities significantly increased from 3.69 ± 1.76 cm/s at day 7 to 24.26 ± 8.42 cm/s at day 21 (n = 5-6, p < 0.05). hPS-CM seeded microthreads exhibited positive expression for connexin 43, a gap junction protein, between cells. These data suggest that the fibrin microthread is a suitable scaffold for hPS-CM attachment and contraction. In addition, extended culture allows cells to contract in the direction of the thread, suggesting alignment of the cells in the microthread direction.
Collapse
Affiliation(s)
- Katrina J. Hansen
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, United States
| | - Michael A. Laflamme
- Toronto General Hospital Research Institute, McEwen Centre for Regenerative Medicine, University Health Network, Toronto, ON, Canada
| | - Glenn R. Gaudette
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, United States
| |
Collapse
|
40
|
Zhang Y, Guo Y, Lee WN. Ultrafast Ultrasound Imaging With Cascaded Dual-Polarity Waves. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:906-917. [PMID: 29610070 DOI: 10.1109/tmi.2017.2781261] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Ultrafast ultrasound imaging using plane or diverging waves, instead of focused beams, has advanced greatly the development of novel ultrasound imaging methods for evaluating tissue functions beyond anatomical information. However, the sonographic signal-to-noise ratio (SNR) of ultrafast imaging remains limited due to the lack of transmission focusing, and thus insufficient acoustic energy delivery. We hereby propose a new ultrafast ultrasound imaging methodology with cascaded dual-polarity waves (CDWs), which consists of a pulse train with positive and negative polarities. A new coding scheme and a corresponding linear decoding process were thereby designed to obtain the recovered signals with increased amplitude, thus increasing the SNR without sacrificing the frame rate. The newly designed CDW ultrafast ultrasound imaging technique achieved higher quality B-mode images than coherent plane-wave compounding (CPWC) and multiplane wave (MW) imaging in a calibration phantom, ex vivo pork belly, and in vivo human back muscle. CDW imaging shows a significant improvement in the SNR (10.71 dB versus CPWC and 7.62 dB versus MW), penetration depth (36.94% versus CPWC and 35.14% versus MW), and contrast ratio in deep regions (5.97 dB versus CPWC and 5.05 dB versus MW) without compromising other image quality metrics, such as spatial resolution and frame rate. The enhanced image qualities and ultrafast frame rates offered by CDW imaging beget great potential for various novel imaging applications.
Collapse
|
41
|
Caenen A, Pernot M, Peirlinck M, Mertens L, Swillens A, Segers P. An in silico framework to analyze the anisotropic shear wave mechanics in cardiac shear wave elastography. Phys Med Biol 2018; 63:075005. [PMID: 29451120 DOI: 10.1088/1361-6560/aaaffe] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Shear wave elastography (SWE) is a potential tool to non-invasively assess cardiac muscle stiffness. This study focused on the effect of the orthotropic material properties and mechanical loading on the performance of cardiac SWE, as it is known that these factors contribute to complex 3D anisotropic shear wave propagation. To investigate the specific impact of these complexities, we constructed a finite element model with an orthotropic material law subjected to different uniaxial stretches to simulate SWE in the stressed cardiac wall. Group and phase speed were analyzed in function of tissue thickness and virtual probe rotation angle. Tissue stretching increased the group and phase speed of the simulated shear wave, especially in the direction of the muscle fiber. As the model provided access to the true fiber orientation and material properties, we assessed the accuracy of two fiber orientation extraction methods based on SWE. We found a higher accuracy (but lower robustness) when extracting fiber orientations based on the location of maximal shear wave speed instead of the angle of the major axis of the ellipsoidal group speed surface. Both methods had a comparable performance for the center region of the cardiac wall, and performed less well towards the edges. Lastly, we also assessed the (theoretical) impact of pathology on shear wave physics and characterization in the model. It was found that SWE was able to detect changes in fiber orientation and material characteristics, potentially associated with cardiac pathologies such as myocardial fibrosis. Furthermore, the model showed clearly altered shear wave patterns for the fibrotic myocardium compared to the healthy myocardium, which forms an initial but promising outcome of this modeling study.
Collapse
Affiliation(s)
- Annette Caenen
- IBiTech-bioMMeda, Ghent University, Ghent, Belgium. Author to whom any correspondence should be addressed
| | | | | | | | | | | |
Collapse
|
42
|
Effect of Ultrafast Imaging on Shear Wave Visualization and Characterization: An Experimental and Computational Study in a Pediatric Ventricular Model. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7080840] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
43
|
Strachinaru M, Bosch JG, van Dalen BM, van Gils L, van der Steen AFW, de Jong N, Geleijnse ML, Vos HJ. Cardiac Shear Wave Elastography Using a Clinical Ultrasound System. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1596-1606. [PMID: 28545859 DOI: 10.1016/j.ultrasmedbio.2017.04.012] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2016] [Revised: 03/08/2017] [Accepted: 04/14/2017] [Indexed: 06/07/2023]
Abstract
The propagation velocity of shear waves relates to tissue stiffness. We prove that a regular clinical cardiac ultrasound system can determine shear wave velocity with a conventional unmodified tissue Doppler imaging (TDI) application. The investigation was performed on five tissue phantoms with different stiffness using a research platform capable of inducing and tracking shear waves and a clinical cardiac system (Philips iE33, achieving frame rates of 400-700 Hz in TDI by tuning the normal system settings). We also tested the technique in vivo on a normal individual and on typical pathologies modifying the consistency of the left ventricular wall. The research platform scanner was used as reference. Shear wave velocities measured with TDI on the clinical cardiac system were very close to those measured by the research platform scanner. The mean difference between the clinical and research systems was 0.18 ± 0.22 m/s, and the limits of agreement, from -0.27 to +0.63 m/s. In vivo, the velocity of the wave induced by aortic valve closure in the interventricular septum increased in patients with expected increased wall stiffness.
Collapse
Affiliation(s)
- Mihai Strachinaru
- Department of Cardiology, Erasmus MC Rotterdam, Rotterdam, The Netherlands.
| | - Johan G Bosch
- Department of Biomedical Engineering, Erasmus MC Rotterdam, Rotterdam, The Netherlands
| | - Bas M van Dalen
- Department of Cardiology, Erasmus MC Rotterdam, Rotterdam, The Netherlands
| | - Lennart van Gils
- Department of Cardiology, Erasmus MC Rotterdam, Rotterdam, The Netherlands
| | - Antonius F W van der Steen
- Department of Biomedical Engineering, Erasmus MC Rotterdam, Rotterdam, The Netherlands; Department of Acoustical Wavefield Imaging, Delft University of Technology, Delft, The Netherlands
| | - Nico de Jong
- Department of Biomedical Engineering, Erasmus MC Rotterdam, Rotterdam, The Netherlands; Department of Acoustical Wavefield Imaging, Delft University of Technology, Delft, The Netherlands
| | - Marcel L Geleijnse
- Department of Cardiology, Erasmus MC Rotterdam, Rotterdam, The Netherlands
| | - Hendrik J Vos
- Department of Biomedical Engineering, Erasmus MC Rotterdam, Rotterdam, The Netherlands; Department of Acoustical Wavefield Imaging, Delft University of Technology, Delft, The Netherlands
| |
Collapse
|
44
|
He Q, Li GY, Lee FF, Zhang Q, Cao Y, Luo J. Novel Method for Vessel Cross-Sectional Shear Wave Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1520-1532. [PMID: 28408062 DOI: 10.1016/j.ultrasmedbio.2017.03.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 02/22/2017] [Accepted: 03/06/2017] [Indexed: 06/07/2023]
Abstract
Many studies have investigated the applications of shear wave imaging (SWI) to vascular elastography, mainly on the longitudinal section of vessels. It is important to investigate SWI in the arterial cross section when evaluating anisotropy of the vessel wall or complete plaque composition. Here, we proposed a novel method based on the coordinate transformation and directional filter in the polar coordinate system to achieve vessel cross-sectional shear wave imaging. In particular, ultrasound radiofrequency data were transformed from the Cartesian to the polar coordinate system; the radial displacements were then estimated directly. Directional filtering was performed along the circumferential direction to filter out the reflected waves. The feasibility of the proposed vessel cross-sectional shear wave imaging method was investigated through phantom experiments and ex vivo and in vivo studies. Our results indicated that the dispersion relation of the shear wave (i.e., the guided circumferential wave) within the vessel can be measured via the present method, and the elastic modulus of the vessel can be determined.
Collapse
Affiliation(s)
- Qiong He
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China
| | - Guo-Yang Li
- Institute of Biomechanics and Medical Engineering, AML, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| | - Fu-Feng Lee
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China
| | - Qihao Zhang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Yanping Cao
- Institute of Biomechanics and Medical Engineering, AML, Department of Engineering Mechanics, Tsinghua University, Beijing, China
| | - Jianwen Luo
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China; Center for Biomedical Imaging Research, Tsinghua University, Beijing, China.
| |
Collapse
|
45
|
Hossain MM, Moore CJ, Gallippi CM. Acoustic Radiation Force Impulse (ARFI)-Induced Peak Displacements Reflect Degree of Anisotropy in Transversely Isotropic Elastic Materials. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:989-1001. [PMID: 28371775 PMCID: PMC8262365 DOI: 10.1109/tuffc.2017.2690223] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
In transversely isotropic (TI) materials, mechanical properties (Young's modulus, shear modulus, and Poisson's ratio) are different along versus across the axis of symmetry (AoS). In this work, the feasibility of interrogating such directional mechanical property differences using acoustic radiation force impulse (ARFI) imaging is investigated. We herein test the hypotheses that 1) ARFI-induced peak displacements (PDs) vary with TI material orientations when an asymmetrical ARFI excitation point spread function (PSF) is used, but not when a symmetrical ARFI PSF is employed; and 2) the ratio of PDs induced with the long axis of an asymmetrical ARFI PSF oriented along versus across the material's AoS is related to the degree of anisotropy of the material. These hypotheses were tested in silico using finite element method (FEM) models and Field II. ARFI excitations had F/1.5, 3, 4, or 5 focal configurations, with the F/1.5 and F/5 cases having the most asymmetrical and symmetrical PSFs at the focal depth, respectively. These excitations were implemented for ARFI imaging in 52 different simulated TI materials with varying degrees of anisotropy, and the ratio of ARFI-induced PDs was calculated. The change in the ratio of PDs with respect to the anisotropy of the materials was highest for the F/1.5, indicating that PD was most strongly impacted by the material orientation when the ARFI excitation was the most asymmetrical. On the contrary, the ratio of PDs did not depend on the anisotropy of the material for the F/5 ARFI excitation, suggesting that PD did not depend on material orientation when the ARFI excitation was symmetrical. Finally, the ratio of PDs achieved using asymmetrical ARFI PSF reflected the degree of anisotropy in TI materials. These results support that symmetrical ARFI focal configurations are desirable when the orientation of the ARFI excitation to the AoS is not specifically known and measurement standardization is important, such as for longitudinal or cross-sectional studies of anisotropic organs. However, asymmetrical focal configurations are useful for exploiting anisotropy, which may be diagnostically relevant. Feasibility for future experimental implementation is demonstrated by simulating ultrasonic displacement tracking and by varying the ARF duration.
Collapse
|
46
|
Imaging the dynamics of cardiac fiber orientation in vivo using 3D Ultrasound Backscatter Tensor Imaging. Sci Rep 2017; 7:830. [PMID: 28400606 PMCID: PMC5429761 DOI: 10.1038/s41598-017-00946-7] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Accepted: 03/20/2017] [Indexed: 01/23/2023] Open
Abstract
The assessment of myocardial fiber disarray is of major interest for the study of the progression of myocardial disease. However, time-resolved imaging of the myocardial structure remains unavailable in clinical practice. In this study, we introduce 3D Backscatter Tensor Imaging (3D-BTI), an entirely novel ultrasound-based imaging technique that can map the myocardial fibers orientation and its dynamics with a temporal resolution of 10 ms during a single cardiac cycle, non-invasively and in vivo in entire volumes. 3D-BTI is based on ultrafast volumetric ultrasound acquisitions, which are used to quantify the spatial coherence of backscattered echoes at each point of the volume. The capability of 3D-BTI to map the fibers orientation was evaluated in vitro in 5 myocardial samples. The helicoidal transmural variation of fiber angles was in good agreement with the one obtained by histological analysis. 3D-BTI was then performed to map the fiber orientation dynamics in vivo in the beating heart of an open-chest sheep at a volume rate of 90 volumes/s. Finally, the clinical feasibility of 3D-BTI was shown on a healthy volunteer. These initial results indicate that 3D-BTI could become a fully non-invasive technique to assess myocardial disarray at the bedside of patients.
Collapse
|
47
|
Ramadan S, Paul N, Naguib HE. Standardized static and dynamic evaluation of myocardial tissue properties. ACTA ACUST UNITED AC 2017; 12:025013. [PMID: 28065929 DOI: 10.1088/1748-605x/aa57a5] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
INTRODUCTION Quantifying the mechanical behaviors of soft biological tissues is of considerable research interest. However, validity and reproducibility between different researchers and apparatus is questionable. This study aims to quantify the mechanical properties of myocardium while investigating methodologies that can standardize biological tissue testing. MATERIALS AND METHODS Tensile testing was performed to obtain Young's modulus and a dynamic mechanical analysis (DMA) determined the viscoelastic properties. A frequency range of 0.5 Hz (30bpm) to 3.5 Hz (210bpm) was analyzed. For tensile testing three different preconditioning settings were tested: no load, 0.05 N preload, and a cyclic preload at 2.5% strain and 10 cycles. Samples were placed in saline and tested at 37 °C. Five ovine and five porcine hearts were tested. RESULTS AND DISCUSSION Cyclic loading results in the most consistent moduli values. The modulus of ovine/porcine tissue was mean = 0.05/.06 MPa, SD = 0.02/0.03 MPa. The storage/loss modulus varied from = 0.02/0.003 MPa at 0.5 Hz to 0.04/0.008 MPa at 3.5 Hz; Stiffness increases linearly from 400 to 800 N m-1 with a tan delta around 0.175. CONCLUSIONS Static analysis of the mechanical properties of myocardial tissue confirms that; preconditioning is necessary for reproducibility, and DMA provides a platform for reproducible testing of soft biological tissues.
Collapse
Affiliation(s)
- Sherif Ramadan
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Rosebrugh Building (RS), 164 College Street, Room 407, Toronto, Ontario M5S 3G9, Canada
| | | | | |
Collapse
|
48
|
Li H, Lee WN. Effects of tissue mechanical and acoustic anisotropies on the performance of a cross-correlation-based ultrasound strain imaging method. Phys Med Biol 2017; 62:1456-1479. [DOI: 10.1088/1361-6560/aa530b] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
49
|
Chrobak MO, Hansen KJ, Gershlak JR, Vratsanos M, Kanellias M, Gaudette GR, Pins GD. Design of a Fibrin Microthread-Based Composite Layer for Use in a Cardiac Patch. ACS Biomater Sci Eng 2017; 3:1394-1403. [DOI: 10.1021/acsbiomaterials.6b00547] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Megan O. Chrobak
- Department
of Biomedical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, Massachusetts 01609, United States
| | - Katrina J. Hansen
- Department
of Biomedical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, Massachusetts 01609, United States
| | - Joshua R. Gershlak
- Department
of Biomedical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, Massachusetts 01609, United States
| | - Maria Vratsanos
- Department
of Biomedical Engineering, Case Western Reserve University, 10900
Euclid Avenue, Cleveland, Ohio 44106, United States
| | - Marianne Kanellias
- Department
of Biomedical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, Massachusetts 01609, United States
| | - Glenn R. Gaudette
- Department
of Biomedical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, Massachusetts 01609, United States
| | - George D. Pins
- Department
of Biomedical Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, Massachusetts 01609, United States
| |
Collapse
|
50
|
D’hooge J, Rademakers F. A Remedy for the Achilles’ Heel of Echocardiography? JACC Cardiovasc Imaging 2016; 9:1031-1033. [DOI: 10.1016/j.jcmg.2015.12.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Accepted: 12/08/2015] [Indexed: 10/21/2022]
|