1
|
Arefnia B, Theisen K, Steyer E, Lorenzoni M, Sokolowski A, Ubaidha Maheen C, Tervahartiala T, Sorsa T, Sokolowski A. Effect of Abutment Material on aMMP-8 Levels in Peri-Implant Sulcular Fluid over 12 Months: A Randomized Controlled Trial. Diagnostics (Basel) 2025; 15:264. [PMID: 39941195 PMCID: PMC11817154 DOI: 10.3390/diagnostics15030264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2024] [Revised: 01/10/2025] [Accepted: 01/20/2025] [Indexed: 02/16/2025] Open
Abstract
Background/Objectives: The long-term success of dental implants can be influenced by the material properties of abutments and their interaction with peri-implant tissues. This study investigates the impact of three abutment materials-titanium (Ti), zirconium oxide (Zr), and polymethylmethacrylate (PMMA)-on the inflammatory response in peri-implant sulcular fluid (PISF), using active-matrix metalloproteinase-8 (aMMP-8) as a biomarker. Methods: In this prospective, randomized clinical trial, 30 patients were assigned to Ti, Zr, or PMMA abutment groups. PISF samples were collected at predefined intervals over 12 months and analyzed for aMMP-8 levels using enzyme-linked immunosorbent assays (ELISA). Clinical parameters (probing depth, bleeding on probing, and plaque index) and radiographic assessments of bone resorption were also evaluated. Results: Two weeks after implant uncovering, baseline aMMP-8 levels varied significantly among materials, with Zr demonstrating the highest levels. Over time (2, 3, 6 and 12 months after implant uncovering), aMMP-8 levels decreased across all groups, with no significant differences observed at 12 months. Radiographic assessments indicated no statistically significant differences in bone resorption, with clinical parameters remaining comparable across all groups. Conclusions: Initial inflammatory responses to abutment materials may vary; however, all tested materials-Ti, Zr, and PMMA-showed long-term biocompatibility and supported healthy peri-implant tissue integration. These findings indicate that selecting any of the tested abutment materials does not significantly affect long-term peri-implant health.
Collapse
Affiliation(s)
- Behrouz Arefnia
- Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, 8010 Graz, Austria; (B.A.)
| | - Kerstin Theisen
- Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, 8010 Graz, Austria; (B.A.)
| | - Elisabeth Steyer
- Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, 8010 Graz, Austria; (B.A.)
| | - Martin Lorenzoni
- Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, 8010 Graz, Austria; (B.A.)
| | - Armin Sokolowski
- Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, 8010 Graz, Austria; (B.A.)
| | - Ceeneena Ubaidha Maheen
- Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, 8010 Graz, Austria; (B.A.)
| | - Taina Tervahartiala
- Department of Oral and Maxillofacial Diseases, Institute of Dentistry, Helsinki University Central Hospital (HUCH), University of Helsinki, 00014 Helsinki, Finland
| | - Timo Sorsa
- Department of Oral and Maxillofacial Diseases, Institute of Dentistry, Helsinki University Central Hospital (HUCH), University of Helsinki, 00014 Helsinki, Finland
| | - Alwin Sokolowski
- Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, 8010 Graz, Austria; (B.A.)
| |
Collapse
|
2
|
Alves Pereira M, Piazza R, Santana AP, Ricardo Barão VA, Malheiros SS, van den Beucken JJJP, de Molon RS, de Avila ED. Unraveling the Applicability of LbL Coatings for Drug Delivery in Dental Implant-Related Infection Treatment. ACS Biomater Sci Eng 2025; 11:13-32. [PMID: 39614932 PMCID: PMC11733916 DOI: 10.1021/acsbiomaterials.4c01037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 10/29/2024] [Accepted: 10/30/2024] [Indexed: 12/06/2024]
Abstract
Peri-implantitis is an inflammatory condition caused by bacterial biofilms adhered on dental implant surfaces that cause progressive tissue destruction from the host's inflammatory response. The adverse effects of peri-implantitis progression can go beyond just losing the implant. This highlights the importance of implementing strategies to stabilize disease in the short term. Layer-by-layer (LbL) assembly is a promising avenue in the field of peri-implantitis management due to its applicability with a variety of substances, in addition to being an easy, versatile, and flexible process for multilayer formation to act directly in the affected site. In this Review, our objective is to offer comprehensive chemical and biological insights into the LbL system, clarifying its specific application as antimicrobial coatings, with concern for the physical site and purpose. Additionally, we delve deeper into the concepts of onset and progression of peri-implantitis, aiming to elucidate the precise indications for employing the LbL system as a coating for implant abutments in peri-implantitis treatment. Finally, we correlate the chemical composition of the LbL system with its functionality while also addressing the challenges posed by the uncontrolled environment of the oral cavity, which ultimately restricts its clinical applicability.
Collapse
Affiliation(s)
- Marta
Maria Alves Pereira
- Department
of Dental Materials and Prosthodontics, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo 14801-903, Brazil
| | - Rodolfo Piazza
- Department
of Physical Chemistry, São Paulo
State University (UNESP), Institute of Chemistry, Araraquara, São Paulo 14801-970, Brazil
| | - Amanda Paino Santana
- Department
of Dental Materials and Prosthodontics, São Paulo State University (UNESP), School of Dentistry, Araçatuba, São
Paulo 16015-050, Brazil
| | - Valentim Adelino Ricardo Barão
- Department
of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | - Samuel Santana Malheiros
- Department
of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | | | - Rafael Scaf de Molon
- Department
of Diagnostic and Surgery, São Paulo
State University (UNESP), School of Dentistry, Araçatuba, São Paulo 16015-050, Brazil
| | - Erica Dorigatti de Avila
- Department
of Dental Materials and Prosthodontics, São Paulo State University (UNESP), School of Dentistry, Araraquara, São Paulo 14801-903, Brazil
- Department
of Dental Materials and Prosthodontics, São Paulo State University (UNESP), School of Dentistry, Araçatuba, São
Paulo 16015-050, Brazil
| |
Collapse
|
3
|
Schoenbaum TR, Papaspyridakos P, Kim YK, Arce C, Knoernschild K. Clinician preferences for single-unit implant restoration designs and materials: A survey of the membership of the Pacific Coast Society for Prosthodontics. J Prosthet Dent 2024; 132:1288-1298. [PMID: 36935268 DOI: 10.1016/j.prosdent.2023.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 02/15/2023] [Accepted: 02/16/2023] [Indexed: 03/19/2023]
Abstract
STATEMENT OF PROBLEM Clinical research has difficulty keeping pace with the rapid evolution of materials, protocols, and designs of single-unit implant restorations. The clinical design preferences of prosthodontics for different clinical scenarios are lacking. PURPOSE The purpose of this cross-sectional survey was to determine the current prevalence of usage of various treatment options and materials for single-unit implant-supported restorations. MATERIAL AND METHODS From August to September of 2022, a survey invitation was sent to members of the Pacific Coast Society for Prosthodontics (PCSP). The survey was hosted online and asked 37 questions related to the materials, protocols, and design preferences for single-unit implant-supported restorations in various clinical scenarios. The prompts included the suggestion that answers should be based on preferences for the "ideal" treatment of a hypothetical patient seeking implant treatment for the replacement of a single missing tooth. RESULTS Of 133 questionnaires sent via email, 35 were returned. The results are presented with histograms that use color coding as an experience proxy metric. A total of 87% of respondents was in private practice, and 60% reported having restored more than 1000 single-unit implant restorations. For the replacement of a single maxillary central incisor under ideal conditions and angulation through the palatal surface, respondents preferred bone level implants (93%) and screw-retained restorations (80%), with 50% of those being zirconia with a titanium abutment and 21% being cast metal-ceramic. For an identical scenario, except that the angulation would be through the facial surface, respondents preferred the angled screw system (55%) and cemented (41%) restorations. For the replacement of a single missing mandibular molar under ideal conditions, respondents preferred bone level implants (79%) and screw-retained restorations (79%), with 70% of those being zirconia with a titanium abutment and 17% being cast metal-ceramic. CONCLUSIONS While a wide range of protocols, designs, and materials exist for the replacement of a single missing tooth, these results provide a snapshot of current single-unit implant prosthodontic preferences in the Western United States and Canada.
Collapse
Affiliation(s)
- Todd R Schoenbaum
- Professor, Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, Ga.
| | - Panos Papaspyridakos
- Associate Professor, Department of Prosthodontics, Tufts School of Dental Medicine, Boston Mass
| | - Young K Kim
- Clinical Assistant Professor, Department of Prosthodontics, New York University, New York, NY
| | - Celin Arce
- Assistant Professor, Department of Restorative Sciences, University of Alabama at Birmingham, Birmingham, Ala
| | - Kent Knoernschild
- Professor, Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, Ga
| |
Collapse
|
4
|
Krebs M, Greilich L, Weigl P, Hess P, Dahmer I, Begić A. Influence of repeated implant-abutment manipulation on the prevalence of peri-implant diseases in complete arch restorations. A retrospective analysis. Clin Implant Dent Relat Res 2024; 26:1260-1269. [PMID: 39257298 PMCID: PMC11660522 DOI: 10.1111/cid.13381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 07/12/2024] [Accepted: 08/05/2024] [Indexed: 09/12/2024]
Abstract
PURPOSE To evaluate the effects of repeated abutment manipulation on the prevalence of peri-implant diseases. MATERIALS AND METHODS A total of 27 edentulous patients (n = 108 implants) immediately restored with double-crown retained implant-supported prostheses were identified for this retrospective study. The test included the one-abutment, one-time care concept (n = 18 patients, n = 72 implants, OAOT) and the control abutment replacement (n = 9 patients, n = 36 implants, AR). A mixed effects model regression was conducted for the variable diagnosis (healthy, peri-implant mucositis, and peri-implantitis) with predictors abutment replacement (presence/absence), number of abutment replacement, category of keratinized mucosa (KM) (2 < KM ≥2 mm), and radiographic bone loss (BL). RESULTS After 3-15 years (mean 10.2 ± 2.8 years), the prevalence of peri-implant mucositis and peri-implantitis in patients in the AR group was 11.1% and 88.9%, corresponding to 22.2% and 55.6% at the implant level, respectively. In OAOT group, none of the implants showed peri-implant mucositis, whereas the prevalence for peri-implantitis at patient and implant level amounted to 5.6% and 5.6%, respectively. The increased number of abutment replacements was significantly associated with the increased probability to diagnose peri-implant mucositis and peri-implantitis (OR: 6.13; 95% CI [2.61, 14.39]) (p < 0.001), whereas the presence of keratinized mucosa was not founded as a significant cofounder. The estimated mean BL in AR group was 1.38 mm larger than in OAOT group (p = 0.0190). CONCLUSIONS The OAOT concept was associated with a lower prevalence of peri-implant diseases.
Collapse
Affiliation(s)
- M. Krebs
- Department of Postgraduate EducationGoethe University, CarolinumFrankfurtGermany
- Privat Practice Dr. Krebs & ColleaguesAlzeyGermany
| | - L. Greilich
- Department of Postgraduate EducationGoethe University, CarolinumFrankfurtGermany
| | - P. Weigl
- Department of Postgraduate EducationGoethe University, CarolinumFrankfurtGermany
| | - P. Hess
- Department of Oral Surgery and ImplantologyGoethe University, CarolinumFrankfurtGermany
| | - I. Dahmer
- Institute of Biostatistics and Mathematical ModelingGoethe University, CarolinumFrankfurtGermany
- Center of Dentistry and Oral MedicineGoethe UniversityFrankfurtGermany
| | - A. Begić
- Department of Oral Surgery and ImplantologyGoethe University, CarolinumFrankfurtGermany
| |
Collapse
|
5
|
Lima JFC, Santos FM, de Miranda TB, Ramos GG, Andia DC, Lima AF, Ciotti DL. Inflammatory and adhesion profile of gingival fibroblasts to lithium disilicate ceramic surfaces. Dent Mater 2024; 40:2025-2033. [PMID: 39358190 DOI: 10.1016/j.dental.2024.09.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 09/15/2024] [Accepted: 09/20/2024] [Indexed: 10/04/2024]
Abstract
OBJECTIVES Lithium disilicate (LS) ceramic emerges as a compelling option for customized implant abutments. However, ensuring its safety and reliability requires clarification on key aspects, notably its impact on inflammation and potential for cell adhesion. This study delves into these considerations, examining the influence of LS ceramic on cytokine release and the transcriptional profile of human gingival fibroblasts (hGFs) in direct contact with various LS surfaces. METHODS hGFs were cultured on LS disks featuring three distinct surfaces (unpolished, polished, and polished glaze), while titanium disks served as reference material and cells cultured directly on plates as controls. The surface of the disks was analyzed using a scanning electron microscope. The cell metabolism was analyzed by MTT test, cytokine release by MAGPIX and the expression of genes related to cell adhesion was evaluated by qPCR. RESULTS The disks exhibited similar topography with smooth surfaces, except for the unpolished LS disks, which had an irregular surface. Contact with LS surfaces did not substantially reduce cell metabolism. Moreover, it generally decreased cytokine release compared to controls, particularly pro-inflammatory mediators like IL-1β, IL-6, and TNF-α. Significantly increased expression of genes related to cell adhesion to LS was observed, comparable to titanium, the gold standard material for implant abutments. SIGNIFICANCE This study unveils that LS ceramic not only fails to trigger pro-inflammatory cytokine release, but also significantly enhances gene expression associated with cell adhesion. These mechanisms are closely linked to gene pathways such as PTK2, SRC, MAPK1, and transcription factors ELK-1 and MYC. In summary, the findings underscore LS ceramic's potential as a biocompatible material for implant abutments, shedding light on its favorable inflammatory response and enhanced cell adhesion properties.
Collapse
Affiliation(s)
| | - Filipe Milazzo Santos
- Dental Research Division, Paulista University, Rua Doutor Bacelar, 1212, Sao Paulo 04026-002, Brazil
| | - Taís Browne de Miranda
- Dental Research Division, Paulista University, Rua Doutor Bacelar, 1212, Sao Paulo 04026-002, Brazil
| | - Guilherme Gama Ramos
- São Leopoldo Mandic Institute and Dental Research Center, Campinas, São Paulo, Brazil
| | - Denise Carleto Andia
- Dental Research Division, Paulista University, Rua Doutor Bacelar, 1212, Sao Paulo 04026-002, Brazil.
| | - Adriano F Lima
- Dental Research Division, Paulista University, Rua Doutor Bacelar, 1212, Sao Paulo 04026-002, Brazil.
| | - Danilo Lazzari Ciotti
- São Leopoldo Mandic Institute and Dental Research Center, Campinas, São Paulo, Brazil.
| |
Collapse
|
6
|
Colepícolo LS, Mourão Martinez MA, Rodrigues AA, Baeta LS, Costa FO. The innovative double or triple dental abutment-implant: Case study with a 3-to-12-year follow-up. Clin Adv Periodontics 2024. [PMID: 39037121 DOI: 10.1002/cap.10300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 05/14/2024] [Accepted: 05/15/2024] [Indexed: 07/23/2024]
Abstract
BACKGROUND The aim of this case study is to present the rationality and scientific evidence of a new design for a double (DA) and triple (TA) dental abutment-implant with their specific new concept of biodynamic optimized peri-implant tissue (BOPiT). METHODS The innovative design of these abutments with a paraboloid geometry was based on BOPiT, simultaneously involving the principles of mechanobiology, biotensegrity, and mechanotransduction. Thus, 37 consecutive individuals/43 cases rehabilitated with single dental implant using the innovative DA (n = 28) and TA (n = 15) on 43 implants were included in this case study. The DA and TA support 2 or 3 dental crowns on a single implant, respectively. Clinic and radiographic examinations were presented at T1 (loading after 4 months) and T2 [final examination with an average follow-up time of 7.2 years (>3 to 12 years)]. RESULTS At T2, mean scores for plaque index, peri-implant bleeding on probing, and peri-implant probing depth were low, depicting healthy peri-implant conditions. All radiographic images showed insignificant annual marginal bone loss (0.022 ± 0.05 mm) when compared to T1, reflecting great bone stability. CONCLUSION DA and TA, based on the BOPiT concept, represent an advantageous, simple and non-invasive mechanism for the longevity and healthy regulation of the peri-implant tissues.
Collapse
Affiliation(s)
- Luciana Silva Colepícolo
- Federal University of Minas Gerais, Institute of Technology and Research (ITP), Belo Horizonte, Minas Gerais, Brazil
- Instituto Universitário Italiano de Rosario, Santa Fé, Argentina
| | - Maria Auxiliadora Mourão Martinez
- Federal University of Minas Gerais, Institute of Technology and Research (ITP), Belo Horizonte, Minas Gerais, Brazil
- Instituto Universitário Italiano de Rosario, Santa Fé, Argentina
| | | | | | - Fernando Oliveira Costa
- School of Dentistry, Department of Periodontology, Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| |
Collapse
|
7
|
Sanz-Sánchez I, Molina A, Martin C, Bollain J, Calatrava J, Sanz M. The effect of one-time abutment placement on clinical and radiographic outcomes: A 5-year randomized clinical trial. Clin Oral Implants Res 2024; 35:609-620. [PMID: 38506392 DOI: 10.1111/clr.14256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 02/22/2024] [Accepted: 03/07/2024] [Indexed: 03/21/2024]
Abstract
OBJECTIVE The aim of this study was to evaluate the long-term (5 years) clinical efficacy of the one-abutment one-time protocol (test) versus the standard of care by placing the definitive abutment on the day of the prosthetic delivery (control). MATERIALS AND METHODS In this study, 39 subjects with 60 implants were randomly allocated to either the test or the control group. Changes in the radiographic interproximal bone levels (DIB), modified sulcus bleeding index, probing depth, modified plaque index, papilla fill (Jemt score), incidence of peri-implantitis and peri-implant mucositis as well as patient-reported outcomes measures (PROMs) were collected and compared at 1, 3 and 5 years. RESULTS At 5 years, the control group showed a greater, although not statistically significant, change in mean DIB values (0.97 mm vs. 0.53 mm). Regarding the other clinical parameters evaluated, no statistically significant differences were observed between groups at any time point. At 5 years, 51% of the implants presented peri-implant mucositis (25.5% in the control and 23.5% in the test), and only one implant in the test group developed peri-implantitis. CONCLUSIONS The connection and disconnection of healing abutments during the healing period was not associated with higher long-term bone loss. Clinical outcomes and PROMs were similar between groups.
Collapse
Affiliation(s)
- Ignacio Sanz-Sánchez
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| | - Ana Molina
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| | - Conchita Martin
- BIOCRAN (Craniofacial Biology: Orthodontics and Dentofacial Orthopedics) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| | - Juan Bollain
- Section of Graduate Periodontology, University Complutense, Madrid, Spain
| | - Javier Calatrava
- Section of Graduate Periodontology, University Complutense, Madrid, Spain
| | - Mariano Sanz
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
8
|
Romito GA, Hassan MA, do Amaral GCLS, Villar CC. Decision-making on peri-implant mucositis management and treatment approaches. Br Dent J 2024; 236:797-801. [PMID: 38789757 DOI: 10.1038/s41415-024-7397-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 12/18/2023] [Accepted: 12/21/2023] [Indexed: 05/26/2024]
Abstract
Peri-implant mucositis is characterised by inflammation of soft tissues surrounding a dental implant without associated bone loss beyond initial remodelling. Early detection and timely intervention are critical to prevent its progression to peri-implantitis. This paper focuses on various treatment options for treating peri-implant mucositis. The cornerstone of professional treatment lies in the mechanical disruption and removal of microbial biofilms around the implant. This can be achieved through careful use of manual or powered instruments, such as ultrasonic scalers or air polishing devices. However, there is a need for further research to determine the most effective single approach for treating peri-implant mucositis. Current evidence does not support the combination of mechanical debridement with locally administered antibiotics. Contrarily, evidence strongly supports the removal, cleaning, and modifications of prostheses to improve both self-performance and professional cleanability. The use of adjunctive therapies like photodynamic therapy and diode laser, in conjunction with mechanical instrumentation, is not currently recommended due to the limited strength of available evidence. Preventive measures emphasise the importance of comprehensive oral hygiene care, encompassing professional guidance and at-home practices, to manage biofilms effectively. This encompasses oral hygiene instruction, regular debridement, and maintenance care. Supporting peri-implant therapy is also vital for ongoing implant monitoring, preventing the recurrence of mucositis, and halting its progression to peri-implantitis. This multifaceted approach is key to effectively managing and treating peri-implant mucositis.
Collapse
Affiliation(s)
- Giuseppe A Romito
- Discipline of Periodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil.
| | - Mohamed A Hassan
- Discipline of Periodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | | | - Cristina C Villar
- Discipline of Periodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
9
|
Mahmoud IA, ElTannir AM, Eissa SM, ElBasty RS. Assessment of crestal bone loss and periodontal parameters of polymer infiltrated ceramic network versus lithium disilicate implant hybrid abutment crowns in the esthetic zone (A randomized clinical trial). Clin Implant Dent Relat Res 2024; 26:333-342. [PMID: 37984494 DOI: 10.1111/cid.13293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 10/30/2023] [Accepted: 11/06/2023] [Indexed: 11/22/2023]
Abstract
BACKGROUND Lithium disilicate can be reliable when restoring implants in the esthetic zone. However, it has a high elastic modulus. This might increase the amount of forces transmitted to the crestal bone. AIM OF THE STUDY To evaluate the crestal bone loss and peri-implant periodontal parameters of polymer infiltrated ceramic network compared to lithium disilicate implant-supported hybrid abutment crowns after 12 months of follow-up. METHODOLOGY 44 patients were enrolled. They were randomly assigned into two groups (n = 22). The first group received 22 implants restored with polymer-infiltrated ceramic network (Vitaenamic) hybrid abutment crowns. The second group received 22 implants restored with lithium disilicate (e.max) hybrid abutment crowns over immediately placed implants in the esthetic zone. Periapical radiographs were taken immediately after prosthetic placement and 1 year later utilizing a parallel technique, to assess crestal bone loss. Periodontal parameters were assessed after 1 year. RESULTS Regarding crestal bone loss, a comparison between group I (Vitaenamic) and group II (e.max) was made by using an Independent t-test, which showed an insignificant difference between them (p > 0.05). A comparison between groups I and II revealed insignificant differences regarding periodontal parameters (probing depth, bleeding on probing, visible plaque, and suppuration). CONCLUSIONS Regarding bone stability and periodontal parameters, polymer infiltrated ceramic network and lithium disilicate hybrid abutment crowns showed comparable results. Both materials showed clinically acceptable hard and soft tissue responses.
Collapse
Affiliation(s)
- Inas Adel Mahmoud
- Fixed Prosthodontics Department, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Adel Mohamed ElTannir
- Fixed Prosthodontics Department, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Sherihan Mohamed Eissa
- Fixed and Removable Prosthodontics Department, Oral and Dental Research Institute, National Research Centre, Cairo, Egypt
| | - Reham Said ElBasty
- Fixed Prosthodontics Department, Faculty of Dentistry, Cairo University, Cairo, Egypt
| |
Collapse
|
10
|
Pesce P, Del Fabbro M, Menini M, De Giovanni E, Annunziata M, Khijmatgar S, Canullo L. Effects of abutment materials on peri-implant soft tissue health and stability: A network meta-analysis. J Prosthodont Res 2023; 67:506-517. [PMID: 37081626 DOI: 10.2186/jpr.jpr_d_22_00223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/22/2023]
Abstract
PURPOSE This systematic review aimed to evaluate the effect of the abutment material on peri-implant soft tissue health and stability. STUDY SELECTION An electronic and hand search was conducted until February 2022. Only prospective randomized trials (RCTs) and controlled clinical trials (CCTs) comparing titanium abutments with abutments made of different materials, with a follow-up of at least 6 months, were selected by two independent reviewers. Data on marginal bone loss (MBL) and peri-implant tissue indexes, i.e., plaque index (PI), bleeding on probing (BOP), probing depth (PD), and recession (REC), were collected. The risk of bias for RCTs and non-RCTs was evaluated according to the tool reported in the Cochrane Handbook for Systematic Reviews of Interventions and the ROBINS-I tool, respectively. Both pairwise and network meta-analyses (NMA) were performed. RESULTS We included 18 relevant studies from 1,437 identified studies. Overall, 612 patients were treated, and 848 abutments were inserted. Five studies presented a low risk of bias. Pairwise meta-analysis showed that, as compared to titanium, zirconia abutments presented a significantly reduced MBL (0.20 mm, 95% Confidence Interval CI [0.14-0.26], P < 0.00001). No significant differences were found for the other outcomes. In the NMA, zirconia abutments demonstrated an 83.3% probability of achieving the highest rank in PI, an 87.0% in BOP, and a 65.0% in PD outcome, suggesting that zirconia abutments generally performed better than titanium and alumina abutments. CONCLUSIONS Within the limits of the present study, zirconia abutments seem a viable alternative to titanium ones.
Collapse
Affiliation(s)
- Paolo Pesce
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, L. Rosanna Benzi, Genoa, Italy
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical, and Dental Sciences, University of Milan, Milan, Italy
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Maria Menini
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, L. Rosanna Benzi, Genoa, Italy
| | - Emanuele De Giovanni
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, L. Rosanna Benzi, Genoa, Italy
| | - Marco Annunziata
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Shahnawaz Khijmatgar
- Department of Biomedical, Surgical, and Dental Sciences, University of Milan, Milan, Italy
| | - Luigi Canullo
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, L. Rosanna Benzi, Genoa, Italy
| |
Collapse
|
11
|
Zuercher AN, Strauss FJ, Paqué PN, Bienz SP, Jung RE, Thoma DS. Randomized controlled pilot study comparing small buccal defects around dental implants treated with a subepithelial connective tissue graft or with guided bone regeneration. Clin Oral Implants Res 2023; 34:1094-1105. [PMID: 37483129 DOI: 10.1111/clr.14140] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 07/05/2023] [Accepted: 07/11/2023] [Indexed: 07/25/2023]
Abstract
AIM To compare subepithelial connective tissue grafts (SCTG) versus guided bone regeneration (GBR) for the treatment of small peri-implant dehiscence defects in terms of profilometric (primary outcome), clinical, and patient-reported outcome measures (PROMs). METHODS Sixteen patients who presented with small buccal bone dehiscences (≤3 mm) following single implant placement were recruited. Following implant placement, buccal bone defect sites were randomly treated either with a SCTG or GBR. Six patients who lacked bone dehiscences after implant placement were assigned to a negative control. Transmucosal healing was applied in all patients. Patients were examined prior (T1) and after (T2) implant placement, at suture removal (T3), at implant impression (T5), at crown delivery (T6), and 12 (T7) months after crown delivery. Measurements included profilometric outcomes, marginal bone levels, buccal bone and soft tissue thickness, PROMs, and clinical parameters. All data were analyzed descriptively. RESULTS The median changes in buccal contour as assessed by profilometric measures between T1 and T5 showed a decrease of 1.84 mm for the SCTG group and 1.06 mm for the GBR group. Between T2 and T7, the median change in the buccal contour amounted to 0.45 mm for SCTG and -0.94 mm (=loss) for GBR. Patients' pain perception tended to be higher in SCTG than in GBR. All peri-implant soft tissue parameters showed healthy oral tissues and no clinically relevant differences between groups. CONCLUSION Within the limitations of this pilot study, treating small peri-implant dehiscence defects with a SCTG might be a viable alternative to GBR. The use of a SCTG tended to result in more stable profilometric outcomes and comparable clinical outcomes to GBR. However, patient-reported outcome measures tended to favor GBR.
Collapse
Affiliation(s)
- A N Zuercher
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - F J Strauss
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - P N Paqué
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - S P Bienz
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - R E Jung
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - D S Thoma
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
12
|
Laleman I, Lambert F, Gahlert M, Bacevic M, Woelfler H, Roehling S. The effect of different abutment materials on peri-implant tissues-A systematic review and meta-analysis. Clin Oral Implants Res 2023; 34 Suppl 26:125-142. [PMID: 37750527 DOI: 10.1111/clr.14159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 09/27/2023]
Abstract
OBJECTIVES In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the surrounding peri-implant tissues after at least 1 year? MATERIALS AND METHODS This systematic review included eligible randomized controlled trials identified through an electronic search (Medline, Embase and Web of Science) comparing alternative abutment materials versus titanium (alloy) abutments with a minimum follow-up of 1 year and including at least 10 patients/group. Primary outcomes were peri-implant marginal bone level (MBL) and probing depth (PD), these were evaluated based on meta-analyses. Abutment survival, biological and technical complications and aesthetic outcomes were the secondary outcomes. The risk of bias was assessed with the RoB2-tool. This review is registered in PROSPERO with the number (CRD42022376487). RESULTS From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 12 articles could be included. Concerning the primary outcomes (MBL and PD), no differences could be seen between titanium abutment and zirconia or alumina abutments, not after 1 year (MBL: zirconia: MD = -0.24, 95% CI: -0.65 to 0.16, alumina: MD = -0.06, 95% CI: -0.29 to 0.17) (PD: zirconia: MD = -0.06, 95% CI: -0.41 to 0.30, alumina: MD = -0.29, 95% CI: -0.96 to 0.38), nor after 5 years. Additionally, no differences were found concerning the biological complications and aesthetic outcomes. The most important technical finding was abutment fracture in the ceramic group and chipping of the veneering material. CONCLUSIONS Biologically, titanium and zirconia abutments seem to function equally up to 5 years after placement.
Collapse
Affiliation(s)
- I Laleman
- Department of Periodontology and Oral Surgery, Faculty of Medicine, University of Liège, Liège, Belgium
- Dental Biomaterials Research Unit (d-BRU), Faculty of Medicine, University of Liège, Liège, Belgium
| | - F Lambert
- Department of Periodontology and Oral Surgery, Faculty of Medicine, University of Liège, Liège, Belgium
- Dental Biomaterials Research Unit (d-BRU), Faculty of Medicine, University of Liège, Liège, Belgium
| | - M Gahlert
- Private Dental Clinic PD Dr. Gahlert & PD Dr. Roehling, Munich, Germany
- Sigmund Freud Private University, Vienna, Austria
- Clinic for Oral and Cranio-Maxillofacial Surgery, Hightech Research Center, University Hospital Basel, University of Basel, Basel, Switzerland
| | - M Bacevic
- Department of Periodontology and Oral Surgery, Faculty of Medicine, University of Liège, Liège, Belgium
- Centre for Oral Clinical Research, Institute of Dentistry, Barts and the London School of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
| | - H Woelfler
- Professor for Demography, University of Bamberg, Bamberg, Germany
| | - S Roehling
- Private Dental Clinic PD Dr. Gahlert & PD Dr. Roehling, Munich, Germany
- Clinic for Oral and Cranio-Maxillofacial Surgery, Hightech Research Center, University Hospital Basel, University of Basel, Basel, Switzerland
- Clinic for Oral and Cranio-Maxillofacial Surgery, Kantonsspital Aarau, Aarau, Switzerland
| |
Collapse
|
13
|
Canullo L, Giuliani A, Furlani M, Menini M, Piattelli A, Iezzi G. Influence of abutment macro- and micro-geometry on morphologic and morphometric features of peri-implant connective tissue. Clin Oral Implants Res 2023; 34:920-933. [PMID: 37345230 DOI: 10.1111/clr.14118] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 05/10/2023] [Accepted: 06/10/2023] [Indexed: 06/23/2023]
Abstract
OBJECTIVES The aim of the present human observational study is to provide morphologic and morphometric analysis of peri-implant connective tissue next to abutments with divergent or convergent macro-geometry and different surface micro-characteristics. MATERIALS AND METHODS Thirty patients were rehabilitated with single implants in the posterior area and one out of three different healing abutments with a one-stage technique: machined divergent abutment (DIV-MAC), machined convergent abutment (CONV-MAC) or convergent abutment with ultrathin threaded surface (CONV-UTM). At 3 months postimplant insertion, peri-implant soft tissue was harvested; the following outcomes were investigated: histomorphometry (vertical width of connective and epithelial components) as detected by histology and polarized light; and connective tissue vertical width and 3D organization as detected by synchrotron-based high-resolution phase-contrast-based tomography (PhC-μCT). RESULTS Significant differences in connective tissue vertical dimension (aJE-AM) were found between DIV-MAC and both CONV-MAC and CONV-UTM, both by histology and PhC-μCT, with significantly higher values for the last two groups. Moreover, 2D histological analysis did not find significant differences in the junctional epithelium vertical dimension (PM-aJE). Importantly, PhC-μCT analysis revealed, at 3D level, significant greater amount and density of collagen bundles for CONV-UTM compared with the other two groups. CONCLUSIONS Convergent abutment profiles, regardless of their surface micro-geometry, seem to favor axial development of peri-implant connective tissue. Moreover, ultrathin threaded surfaces seem associated with denser and greater connective tissue organization, which might improve peri-implant soft tissue seal.
Collapse
Affiliation(s)
- Luigi Canullo
- Unit of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genova, Genova, Italy
| | - Alessandra Giuliani
- Section BBF, Department of Clinical Sciences (DiSCO), Polytechnic University of Marche, Ancona, Italy
| | - Michele Furlani
- Section BBF, Department of Clinical Sciences (DiSCO), Polytechnic University of Marche, Ancona, Italy
| | - Maria Menini
- Unit of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genova, Genova, Italy
| | - Adriano Piattelli
- Dental School, University of Belgrade, Belgrade, Serbia
- School of Dentistry, Saint Camillus International University of Health and Medical Sciences, Rome, Italy
- Fondazione Villa Serena per la Ricerca, Città Sant'Angelo, Italy
- Casa di Cura Villa Serena del Dott. L. Petruzzi, Città Sant'Angelo, Italy
| | - Giovanna Iezzi
- Department of Medical, Oral and Biotechnological Sciences, University G. d'Annunzio of Chieti-Pescara, Chieti, Italy
| |
Collapse
|
14
|
Chantler JGM, Evans CDJ, Zitzmann NU, Derksen W. Clinical performance of single implant prostheses restored using titanium base abutments: A systematic review and meta-analysis. Clin Oral Implants Res 2023; 34 Suppl 26:64-85. [PMID: 37750524 DOI: 10.1111/clr.14128] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 06/16/2023] [Accepted: 06/21/2023] [Indexed: 09/27/2023]
Abstract
PURPOSE The aim of this review was to evaluate the survival rates of restorations utilizing titanium base abutments (TBA) for restoring single-unit implant prostheses. MATERIALS AND METHODS This review was conducted following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines. The focus question was: In patients who require the restoration of a single dental implant utilizing a titanium base abutment, what are the determining factors and outcomes relating to implant prosthesis prognosis and survival? A comprehensive search of databases (PubMed, EMBASE, and Cochrane Library) was conducted on 16 April 2023 and updated on 5 May 2023. Randomized clinical trials (RCT), retrospective studies and prospective studies, reporting on the use of TBA for single implant prostheses, were reviewed. A Cochrane collaboration risk of bias assessment analysis was performed for randomized clinical studies, and the Newcastle-Ottawa Scale tool was applied for non-randomized studies. A meta-analysis was performed on clinical trials reporting on survival rates of both TBA and other abutments. Other clinical studies, reporting on TBA only, were included for descriptive statistics. RESULTS The search provided 1159 titles after duplicates were removed. Six RCTs were included to perform a meta-analysis and compare the survival of the TBA to other abutments [OR 0.74; 95% CI: 0.21-2.63, heterogeneity; I2 0%; p = .99]. Twenty-three prospective and retrospective studies fulfilled the criteria and were included in the meta-analysis after 12 months of function. A total of 857 single implant-supported prostheses fabricated with a TBA were included. TBA abutments have an estimate 98.6% survival rate after 1 year in function (95% CI: 97.9%-99.4%). The mean follow-up period was 31.2 ± 16.9 months. CONCLUSIONS Single implant prosthesis restored with titanium base abutments showed favourable short-term survival rates.
Collapse
Affiliation(s)
| | | | - Nicola U Zitzmann
- Department of Reconstructive Dentistry, University of Basel, Basel, Switzerland
| | - Wiebe Derksen
- Department of Oral Implantology and Prosthetic Dentistry, Amsterdam, Netherlands
| |
Collapse
|
15
|
Baus-Domínguez M, Maza-Solano S, Vázquez-Pachón C, Flores-Cerero M, Torres-Lagares D, Serrera-Figallo MÁ, Macías-García L. Behaviour of the Peri-Implant Soft Tissue with Different Rehabilitation Materials on Implants. Polymers (Basel) 2023; 15:3321. [PMID: 37571215 PMCID: PMC10422441 DOI: 10.3390/polym15153321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 07/31/2023] [Accepted: 08/04/2023] [Indexed: 08/13/2023] Open
Abstract
(1) Background: Mucointegration seems to gain interest when talking about success in the maintenance of dental implants. As we well know, collagen fibres cannot be inserted due to the lack of root structure on the implant surface, so the structural integration of peri-implant tissues that provide a firm seal around implants seems to be of interest when it comes to ensuring the survival of dental implants. To achieve a good epithelial barrier, the physicochemical characteristics of the surfaces of the restorative materials are of vital importance; therefore, the objective of this study is to analyse the histological behaviour of the peri-implant soft tissues in three different restorative materials. (2) Methods: Histological analysis of biopsied peri-implant keratinised mucosa, inflammatory epithelium and connective tissue in contact with a reinforced composite (BRILLIANT Crios), a cross-linked polymethylmethacrylate (TELIO CAD), and a hybrid ceramic (Vita Enamic), restored on a customised Atlantis-type abutment (Dentsply Sirona) between 60 and 180 days after restoration. (3) Results: A greater number of cells per mm2 of keratinised epithelium is observed in the reinforced composite, which could indicate greater surface roughness with greater inflammatory response. In this way, the greater number of lymphocytes and the lateral cellular composition of the inflammatory cells confirm the greater inflammatory activity towards that material. The best material to rehabilitate was hybrid ceramic, as it shows a better cellular response. (4) Conclusions: Knowing the limitations of the proposed study, despite the fact that greater inflammation is observed in the reinforced composite relative to the other materials studied, no statistically significant differences were found.
Collapse
Affiliation(s)
- María Baus-Domínguez
- Instituto de Biomedicina de Sevilla, IBiS/Departamento de Estomatología, Facultad de Odontología, Universidad de Sevilla, C/Avicena S/N, 41009 Sevilla, Spain; (M.B.-D.); (S.M.-S.); (C.V.-P.); (M.F.-C.); (D.T.-L.)
| | - Serafín Maza-Solano
- Instituto de Biomedicina de Sevilla, IBiS/Departamento de Estomatología, Facultad de Odontología, Universidad de Sevilla, C/Avicena S/N, 41009 Sevilla, Spain; (M.B.-D.); (S.M.-S.); (C.V.-P.); (M.F.-C.); (D.T.-L.)
| | - Celia Vázquez-Pachón
- Instituto de Biomedicina de Sevilla, IBiS/Departamento de Estomatología, Facultad de Odontología, Universidad de Sevilla, C/Avicena S/N, 41009 Sevilla, Spain; (M.B.-D.); (S.M.-S.); (C.V.-P.); (M.F.-C.); (D.T.-L.)
| | - Marta Flores-Cerero
- Instituto de Biomedicina de Sevilla, IBiS/Departamento de Estomatología, Facultad de Odontología, Universidad de Sevilla, C/Avicena S/N, 41009 Sevilla, Spain; (M.B.-D.); (S.M.-S.); (C.V.-P.); (M.F.-C.); (D.T.-L.)
| | - Daniel Torres-Lagares
- Instituto de Biomedicina de Sevilla, IBiS/Departamento de Estomatología, Facultad de Odontología, Universidad de Sevilla, C/Avicena S/N, 41009 Sevilla, Spain; (M.B.-D.); (S.M.-S.); (C.V.-P.); (M.F.-C.); (D.T.-L.)
| | - María-Ángeles Serrera-Figallo
- Instituto de Biomedicina de Sevilla, IBiS/Departamento de Estomatología, Facultad de Odontología, Universidad de Sevilla, C/Avicena S/N, 41009 Sevilla, Spain; (M.B.-D.); (S.M.-S.); (C.V.-P.); (M.F.-C.); (D.T.-L.)
| | - Laura Macías-García
- Departamento de Citología e Histología Normal y Patológica, Facultad de Medicina, Universidad de Sevilla, Avda. Sánchez-Pizjuán S/N, 41009 Sevilla, Spain
| |
Collapse
|
16
|
Gulati K, Chopra D, Kocak-Oztug NA, Verron E. Fit and forget: The future of dental implant therapy via nanotechnology. Adv Drug Deliv Rev 2023; 199:114900. [PMID: 37263543 DOI: 10.1016/j.addr.2023.114900] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/11/2023] [Accepted: 05/21/2023] [Indexed: 06/03/2023]
Abstract
Unlike orthopedic implants, dental implants require the orchestration of both osseointegration at the bone-implant interface and soft-tissue integration at the transmucosal region in a complex oral micro-environment with ubiquitous pathogenic bacteria. This represents a very challenging environment for early acceptance and long-term survival of dental implants, especially in compromised patient conditions, including aged, smoking and diabetic patients. Enabling advanced local therapy from the surface of titanium-based dental implants via novel nano-engineering strategies is emerging. This includes anodized nano-engineered implants eluting growth factors, antibiotics, therapeutic nanoparticles and biopolymers to achieve maximum localized therapeutic action. An important criterion is balancing bioactivity enhancement and therapy (like bactericidal efficacy) without causing cytotoxicity. Critical research gaps still need to be addressed to enable the clinical translation of these therapeutic dental implants. This review informs the latest developments, challenges and future directions in this domain to enable the successful fabrication of clinically-translatable therapeutic dental implants that would allow for long-term success, even in compromised patient conditions.
Collapse
Affiliation(s)
- Karan Gulati
- The University of Queensland, School of Dentistry, Herston, QLD 4006, Australia.
| | - Divya Chopra
- The University of Queensland, School of Dentistry, Herston, QLD 4006, Australia
| | - Necla Asli Kocak-Oztug
- The University of Queensland, School of Dentistry, Herston, QLD 4006, Australia; Istanbul University, Faculty of Dentistry, Department of Periodontology, 34116 Istanbul, Turkey
| | - Elise Verron
- Nantes Université, CNRS, CEISAM, UMR 6230, 44000 Nantes, France
| |
Collapse
|
17
|
Lops D, Romeo E, Mensi M, Troiano G, Zhurakivska K, Del Fabbro M, Palazzolo A. CAD/CAM Abutments in the Esthetic Zone: A Systematic Review and Meta-Analysis of Soft Tissue Stability. J Clin Med 2023; 12:jcm12113847. [PMID: 37298041 DOI: 10.3390/jcm12113847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 05/25/2023] [Accepted: 06/02/2023] [Indexed: 06/12/2023] Open
Abstract
Computer-aided design and computer-aided manufacturing customized abutments are increasingly used in everyday clinical practice. Nevertheless, solid scientific evidence is currently lacking regarding their potential advantages in terms of soft tissue stability. The main aim of this systematic review and meta-analysis was to compare the soft tissue outcomes of prefabricated versus customized (CAD/CAM) abutments. The present review was registered with PROSPERO (CRD42020161875) and the protocol was developed according to the PRISMA statement. An electronic search was performed on three databases (PubMed, Embase and Cochrane Central) up to May 2023. Data extraction was followed by qualitative and quantitative analysis of the included studies. Three randomized controlled clinical trials and three controlled clinical trials (number of patients = 230; number of dental implants = 230) with a follow-up of between 12 and 36 months were included. No significant differences were observed between prefabricated versus customized (CAD/CAM) abutments regarding midfacial mucosal recession, interproximal papillae and pink aesthetic score (PES) after 12 months. Conclusion: The potential benefits of CAD/CAM abutments on soft tissues should be better clarified in future investigations. The usage of customized CAD/CAM abutments in everyday clinical practice should be based on a careful case-by-case evaluation (CRD42020161875).
Collapse
Affiliation(s)
- Diego Lops
- Department of Biomedical, Surgical and Dental Sciences, Dental Clinic, School of Dentistry, University of Milan, 20122 Milan, Italy
| | - Eugenio Romeo
- Department of Biomedical, Surgical and Dental Sciences, Dental Clinic, School of Dentistry, University of Milan, 20122 Milan, Italy
| | - Magda Mensi
- Department of Surgical Specialties, Radiological Science and Public Health, University of Brescia, 25123 Brescia, Italy
| | - Giuseppe Troiano
- Department of Clinical and Experimental Medicine, University of Foggia, 71122 Foggia, Italy
| | - Khrystyna Zhurakivska
- Department of Clinical and Experimental Medicine, University of Foggia, 71122 Foggia, Italy
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Antonino Palazzolo
- Department of Biomedical, Surgical and Dental Sciences, Dental Clinic, School of Dentistry, University of Milan, 20122 Milan, Italy
| |
Collapse
|
18
|
Halim FC, Pesce P, De Angelis N, Benedicenti S, Menini M. Comparison of the Clinical Outcomes of Titanium and Zirconia Implant Abutments: A Systematic Review of Systematic Reviews. J Clin Med 2022; 11:jcm11175052. [PMID: 36078982 PMCID: PMC9456707 DOI: 10.3390/jcm11175052] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 08/25/2022] [Accepted: 08/26/2022] [Indexed: 01/07/2023] Open
Abstract
Background: Dental implants are widely used and in order to answer to esthetic demands, zirconia has been introduced as an abutment material as an alternative to titanium. Several studies have been published on this topic, but the results have been often inconsistent. The objective of the present study is to systematically analyze the existing literature comparing clinical outcomes of titanium and zirconia implant abutments. The study was designed as a systematic review of systematic reviews. Methods: This systematic review is in accordance with the Transparent Reporting of Systematic Reviews and Meta-analyses. A MEDLINE/PubMed, Cochrane Database of Systematic Reviews and SCOPUS literature search was performed up to and including June 2021. Data were extracted independently by two reviewers and tAMSTAR2 was used to assess the quality of the systematic reviews. Results: The electronic search identified 1146 papers, and 175 duplicates were removed. After manual screening, 954 studies were excluded and the final analysis was conducted on 11 papers. Both mechanical and esthetic outcomes and biological complications were analyzed. Conclusions: It can be concluded that titanium abutments have a better mechanical resistance than zirconia ones. Plaque accumulation is reported to be slightly higher on titanium but without any significant inflammatory process. The esthetic outcomes seem to be more related to the thickness (>3 mm) of the soft tissues than to the abutment material.
Collapse
Affiliation(s)
| | - Paolo Pesce
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| | - Nicola De Angelis
- Division of Restorative Dentistry and Endodontics, Department of Surgical Sciences (DISC), University of Genoa, 16126 Genoa, Italy
- Dental Department, University Tunku Abdul Raman, Sungai Buloh 47000, Malaysia
- Dental Department, University Trisakti, Jakarta 11440, Indonesia
- Correspondence:
| | - Stefano Benedicenti
- Division of Restorative Dentistry and Endodontics, Department of Surgical Sciences (DISC), University of Genoa, 16126 Genoa, Italy
| | - Maria Menini
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| |
Collapse
|
19
|
Del Castillo R, Chochlidakis K, Galindo-Moreno P, Ercoli C. Titanium Nitride Coated Implant Abutments: From Technical Aspects And Soft tissue Biocompatibility to Clinical Applications. A Literature Review. J Prosthodont 2022; 31:571-578. [PMID: 34731520 DOI: 10.1111/jopr.13446] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/26/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To review the most up to date scientific evidence concerning the technical implications, soft tissue biocompatibility, and clinical applications derived from the use of titanium nitride hard thin film coatings on titanium alloy implant abutments. MATERIALS AND METHODS A review was performed to answer the following focused question: "What is the clinical reliability of nitride coated titanium alloy abutments?". A MEDLINE search between 1980 and 2021 was performed for investigations pertaining to the clinical use of nitride coated titanium alloy implant abutments (TiN) in case reports, case series, and short- and long-term non/randomized controlled clinical trials. Literature analysis led to addition evaluation of research related to the technical and biological aspects, as well as the physicochemical characteristics of TiN hard thin film coatings and their impact on titanium abutment biocompatibility, mechanical properties, macroscopic surface topography, and optical properties. Therefore, preclinical data from biomechanical and in vitro investigations were also considered as inclusion criteria. RESULTS The limited number of clinical investigations published made a systematic review and meta-analysis not possible, therefore a narrative review was conducted. TiN coatings have been applied to dental materials and instruments to improve their clinical longevity. Implant abutments are coated with titanium nitride to mask the titanium oxide surface and enhance its surface characteristics providing the TiN abutment surface with a low friction coefficient and a very high chemical inertness. TiN coating is suggested to reduce early bacterial colonization and biofilm formation and enhance fibroblast cell proliferation, attachment and adhesion when compared to Ti controls. Additionally, studies indicate that hard thin film coatings enhance the mechanical properties (hardness and wear resistance) of titanium alloy and appears as a yellow color when deposited on the titanium alloy substrate. To date, clinical investigations show that nitride coated titanium abutments provide promising short-term clinical outcomes. CONCLUSIONS Published research on nitride-coated abutments is still limited, however, the available biomedical research, mechanical engineering tests, in vitro investigations, and short-term clinical trials have, to date, reported promising mechanical, biological, and esthetic outcomes.
Collapse
Affiliation(s)
- Rafael Del Castillo
- Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, NY
| | - Konstantinos Chochlidakis
- Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, NY
| | - Pablo Galindo-Moreno
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, Granada, Spain
| | - Carlo Ercoli
- Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, NY
- Department of Prosthodontics and Periodontology, Eastman Institute for Oral Health, University of Rochester, Rochester, NY
| |
Collapse
|
20
|
Histologic Evaluation of Soft Tissues around Dental Implant Abutments: A Narrative Review. MATERIALS 2022; 15:ma15113811. [PMID: 35683109 PMCID: PMC9181750 DOI: 10.3390/ma15113811] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 05/13/2022] [Accepted: 05/25/2022] [Indexed: 01/28/2023]
Abstract
The basis for dental implant success comes not only with the titanium implant osseointegration but also depends on other factors such as the development of a soft tissue barrier, which protects the peri-implant bone from the oral environment. The characteristics of surfaces in contact with peri-implant soft tissues may affect the capacity of peri-implant mucosal cells to create a tight seal around the implant, thus influencing long-term implant success. Many histological studies on animals have been conducted on different materials to better understand their influence on peri-implant soft tissues, with the limitation that results from animal studies cannot be fully translated in humans. The aim of this review paper was to analyze the literature focusing on histological clinical studies in humans which have examined different materials or different surface treatments and their effects on peri-implant soft tissues. The research was conducted according to the following PICO question: “Do different implant/abutment materials affect peri-implant soft tissues adhesion and health?”. Nine articles were analyzed in this review. The results of this review show the influence of different abutment materials on the peri-implant soft tissues, and the need of further research regarding the effect that abutment materials, surface treatments, and surface properties have on soft tissues.
Collapse
|
21
|
Enkling N, Marder M, Bayer S, Götz W, Stoilov M, Kraus D. Soft tissue response to different abutment materials: A controlled and randomized human study using an experimental model. Clin Oral Implants Res 2022; 33:667-679. [PMID: 35467040 DOI: 10.1111/clr.13932] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 02/01/2022] [Accepted: 04/12/2022] [Indexed: 11/28/2022]
Abstract
OBJECTIVES Aim of this study was to compare the soft-tissue response to implant abutments made of titanium, zirconia, zirconia veneered with feldspar ceramics and PEEK by various clinical, histological, microbiological and molecular biological markers in an experimental model. MATERIALS AND METHODS 40 experimental one-piece healing abutments of four different materials were mounted on bone-level implants in 20 volunteering patients (split-mouth design). After a three months period of open healing, clinical parameters at the abutments were assessed and adjacent mucosa was sampled for inflammatory cytokine mRNA-concentrations and histological analysis by a novel method. In addition, PISF-samples were obtained for the analysis of periodonto-pathogenic bacteria counts and active MMP-8 levels. Marginal bone level change was measured by intra oral radiographs. RESULTS Abutments of the different materials did not exhibit significant differences regarding clinical parameters, pathogenic bacteria counts or pro-inflammatory cytokine concentrations. Likewise, no significant differences were detected regarding soft tissue morphology or bone level change. Compared to titanium abutments, significantly less mononuclear inflammatory cells were detected in the mucosa at abutments made of zirconia veneered with feldspar ceramics. CONCLUSIONS All examined abutment materials exhibited a similar soft tissue response compared to titanium and histological data did not reveal early signs of elevated inflammation caused by PEEK- and feldspar-veneered zirconia abutments. Due to the short observation period and the small sample size, a final conclusion on the long term suitability of those abutment materials cannot be drawn. However, based on the presented data, we consider further studies on that subject as appropriate.
Collapse
Affiliation(s)
- Norbert Enkling
- Department of Prosthodontics, Preclinical Education and Material Sciences, University of Bonn.,Department of Reconstructive Dentistry and Gerodontology, University of Bern
| | - Michael Marder
- Department of Prosthodontics, Preclinical Education and Material Sciences, University of Bonn
| | - Stefan Bayer
- Department of Prosthodontics, Preclinical Education and Material Sciences, University of Bonn
| | - Werner Götz
- Department of Orthodontics, University of Bonn
| | - Milan Stoilov
- Department of Prosthodontics, Preclinical Education and Material Sciences, University of Bonn
| | - Dominik Kraus
- Department of Prosthodontics, Preclinical Education and Material Sciences, University of Bonn
| |
Collapse
|
22
|
Evaluation of Zirconia and High Performance Polymer Abutment Surface Roughness and Stress Concentration for Implant-Supported Fixed Dental Prostheses. COATINGS 2022. [DOI: 10.3390/coatings12020238] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Background: The High Performance Polymer is a based polymer biomaterial that was introduced as dental material to manufacture dentures superstructure and dental implants abutments. However, its surface characteristics and stress state still need to be properly described. The aim of this study was to compare the surface characteristics of a High Performance Polymer (Bio-HPP, Bredent, Senden, Germany) for computer-aided design and computer-aided manufacturing (CAD/CAM) milling and a Zirconia (Zirkonzahn, Steger, Ahrntal, Italy). Methods: The abutments surface roughness (Ra) was evaluated for each abutment material (N = 12) using a confocal laser microscope. Data were evaluated using One-Way ANOVA and Tukey tests (p < 0.05). In addition, a finite element analysis software was used to present stress measurement data as stress maps with 100 N loading. Results were generated according to Von-mises stress criteria and stress peaks were recorded from each structure. Results: Results showed a mean Ra of 0.221 ± 0.09 μm for Bio-HPP and 1.075 ± 0.24 μm for Zirconia. Both surface profiles presented a smooth characteristic regardless the measurement axis. The stress peaks from implant fixture and screw were not affected by the abutment material, however the high performance polymer showed the highest stress magnitude for the abutment region. Conclusions: Comparing the present results with the literature it is suggested that the CAD/CAM High Performance Polymer abutments present an adequate surface roughness with acceptable values of stress.
Collapse
|
23
|
Rathe F, Junker R, Gröger S, Meyle J, Schlee M. Inflammatory effects of individualized abutments bonded onto titanium base on peri-implant tissue health: A randomized controlled clinical trial. Clin Implant Dent Relat Res 2021; 23:874-882. [PMID: 34668304 DOI: 10.1111/cid.13050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 08/29/2021] [Accepted: 09/28/2021] [Indexed: 12/20/2022]
Abstract
BACKGROUND In implant prosthodontics, computer-assisted design and computer-assisted manufacturing (CAD/CAM) zirconia abutments bonded onto titanium bases are frequently used in prosthetic dentistry. Unpolymerized monomer of the bonding material or the adhesive gap itself may have a negative effect on peri-implant tissue health. However, evidence addressing this problem is not available. PURPOSE The aim of the current trial was to study inflammatory effects of individualized abutments bonded onto titanium bases. MATERIAL AND METHOD A total of 24 patients with one test abutment and one control abutment each participated in this prospective, double-blind, randomized controlled clinical trial. Thereby, test abutments were CAD/CAM titanium abutments bonded onto titanium abutments (Ti-Base). As control abutments individualized, one-piece CAD/CAM titanium abutments were used. At abutment installation as well as 6 and 12 months thereafter bone level changes, clinical parameters as well as Il-1β levels were assessed. RESULTS Neither for bone level or clinical parameters nor for Il-1β levels, significant differences between test and control abutments could be found. However, in both groups Il-1β levels were significantly elevated at both the 6 and 12 months follow-up compared to baseline. CONCLUSION Within the limits of this RCT, it can be concluded that effects on the inflammatory state of peri-implant tissues do not differ between individualized abutments bonded onto Ti-Bases and individualized one-piece abutments.
Collapse
Affiliation(s)
- Florian Rathe
- Department of Prosthodontics and Biomaterials, DANUBE Private University, Krems an der Donau, Austria.,Private Office of Implantology and Periodontology, Forchheim, Germany
| | - Rüdiger Junker
- Department of Prosthodontics and Biomaterials, DANUBE Private University, Krems an der Donau, Austria
| | - Sabine Gröger
- Department of Periodontology, Justus Liebig-University, Gießen, Germany
| | - Jörg Meyle
- Department of Periodontology, Justus Liebig-University, Gießen, Germany
| | - Markus Schlee
- Private Office of Implantology and Periodontology, Forchheim, Germany.,Department of Maxillofacial Surgery, Johann Wolfgang von Goethe University, Frankfurt, Germany
| |
Collapse
|
24
|
Mattheos N, Janda M, Acharya A, Pekarski S, Larsson C. Impact of design elements of the implant supracrestal complex (ISC) on the risk of peri-implant mucositis and peri-implantitis: A critical review. Clin Oral Implants Res 2021; 32 Suppl 21:181-202. [PMID: 34642979 DOI: 10.1111/clr.13823] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 07/11/2021] [Accepted: 07/20/2021] [Indexed: 12/27/2022]
Abstract
OBJECTIVE The aim of this review was to investigate the evidence correlating the emergence profile (EP) and emergence angle (EA), peri-implant tissue height, implant neck design, abutment and/or prosthesis material, retention and connection types with risk of peri-implant mucositis and peri-implantitis. METHODS Seven focus questions were identified, and seven electronic search queries were conducted in PubMed. Human studies reporting on bleeding on probing, probing depth or case definitions of peri-implant mucositis and peri-implantitis were included. RESULTS Emerging evidence with bone-level implants suggests a link between EA combined with convex EP and peri-implantitis. Depth of the peri-implant sulcus of ≥3 mm is shown to be reducing the effectiveness of treatment of established peri-implant mucositis. Modification of the prosthesis contour is shown to be an effective supplement of the anti-infective treatment of peri-implant mucositis. Limited evidence points to no difference with regard to the risk for peri-implant mucositis between tissue- and bone-level implants, as well as the material of the abutment or the prosthesis. Limited evidence suggests the use or not of prosthetic abutments in external connections and does not change the risk for peri-implantitis. Literature with regard to prosthesis retention type and risk for peri-implantitis is inconclusive. CONCLUSIONS Limited evidence indicates the involvement of EA, EP, sulcus depth and restricted accessibility to oral hygiene in the manifestation and/or management of peri-implant mucositis/peri-implantitis. Conclusions are limited by the lack of consensus definitions and validated outcomes measures, as well as diverse methodological approaches. Purpose-designed studies are required to clarify current observations.
Collapse
Affiliation(s)
- Nikos Mattheos
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.,Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| | - Martin Janda
- Department of Prosthodontics, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Aneesha Acharya
- Department of Periodontics, Dr. D. Y. Patil Dental College and Hospital, Pune, India
| | - Stephanie Pekarski
- Department of Periodontology, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Christel Larsson
- Department of Prosthodontics, Faculty of Odontology, Malmö University, Malmö, Sweden
| |
Collapse
|
25
|
Biocompatibility of Lithium Disilicate and Zirconium Oxide Ceramics with Different Surface Topographies for Dental Implant Abutments. Int J Mol Sci 2021; 22:ijms22147700. [PMID: 34299319 PMCID: PMC8306444 DOI: 10.3390/ijms22147700] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 07/12/2021] [Accepted: 07/17/2021] [Indexed: 01/11/2023] Open
Abstract
Gingivafibroblasts were cultured on lithium disilicate, on zirconia dioxide, and on titanium with two different surface roughnesses (0.2 µm and 0.07 µm); Proliferation (MTT), Living/Dead staining, cytotoxicity (LDH), proliferation (FGF2), and inflammation (TNFα) were analyzed after 1 day and 21 days. Furthermore, alteration in cell morphology (SEM) was analyzed. The statistical analysis was performed by a Kruskal-Wallis test. The level of significance was set at p < 0.05. There were no distinct differences in cellular behavior between the tested roughness. There were slight differences between tested materials. Cells grown on zirconia dioxide showed higher cytotoxic effects. Cells grown on lithium disilicate showed less expression of TNFα compared to those grown on zirconia dioxide or titanium. These effects persisted only during the first time span. The results indicate that the two tested high-strength ceramics and surface properties are biologically suitable for transmucosal implant components. The findings may help clinicians to choose the most appropriate biomaterial as well as the most appropriate surface treatment to use in accordance with specific clinical dental applications.
Collapse
|
26
|
Canullo L, Penarrocha Oltra D, Pesce P, Zarauz C, Lattanzio R, Penarrocha Diago M, Iezzi G. Soft tissue integration of different abutment surfaces: An experimental study with histological analysis. Clin Oral Implants Res 2021; 32:928-940. [PMID: 34036644 DOI: 10.1111/clr.13782] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 03/21/2021] [Accepted: 05/12/2021] [Indexed: 12/26/2022]
Abstract
OBJECTIVE To evaluate whether abutment surface and surface bio-activation have an effect on soft tissue morphogenesis. MATERIALS AND METHODS 36 patients (36 implants) were included. Abutments were randomly divided into 4 groups (n = 9): Smooth Surface-MAChined (MAC), Ultrathin Threaded Microsurface (UTM), MAC Plasma of Argon activated (Plasma-MAC), and UTM Plasma of Argon activated (Plasma-UTM). After 2 months of healing, soft tissue samples were collected and prepared for histological analysis. The margin of the peri-implant mucosa (PM), the apical extension of the barrier epithelium (aJE), and the apical location of the abutment (AM) were identified. Significances of differences among groups were tested by means of the Kruskal-Wallis test and between pairs of results by means of the Mann-Whitney test. RESULTS The mean (SD) vertical dimension of the mucosa was 2.5mm (1.0), including a connective tissue portion (CTP) of 0.8mm (0.8) in the MAC group; 3.6mm (0.2) with a CTP of 1.6mm (0.4) in the Plasma-MAC group; 3.2mm (1.0), with a CPT of 0.5mm (0.6) in the UTM; and 3.3mm (0.8), with a CPT of 0.9mm (0.7) in the Plasma-UTM group. Statistically significant differences were observed in the aJE-AM height and PM-aJE profile among the four experimental groups (p = .042 and p = .039, respectively). The Mann-Whitney test indicated differences between the Plasma-abutments and the untreated abutments both for PM-AM (p = .025) and AjE-AM (p = .021). The differences appeared more evident when the preoperative soft tissue thickness was ≤2mm. CONCLUSIONS Within its limits, the study demonstrated a favorable effect of the plasma treatment on the connective tissue portion tissues. Plasma-MAC group highlighted the best performance. This behavior appeared strictly correlated with the soft tissue thickness.
Collapse
Affiliation(s)
- Luigi Canullo
- Department of Oral Surgery and Implants, University of Valencia, Valencia, Spain
| | | | - Paolo Pesce
- Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, Genoa, Italy
| | - Cristina Zarauz
- Department of Fixed Prosthodontics, University of Geneva, Geneva, Switzerland
| | - Rossano Lattanzio
- Department of Innovative Technologies in Medicine & Dentistry, Center for Advanced Studies and Technology (CAST), 'G. d'Annunzio' University of Chieti-Pescara, Chieti, Italy
| | | | - Giovanna Iezzi
- Department of Medical, Oral and Biotechnological Sciences, 'G. d'Annunzio' University of Chieti-Pescara, Chieti, Italy
| |
Collapse
|
27
|
Prosthodontics Using Removable Platform Switching Technologies (Multiunit, On1) as Exemplified by Conical Connection Implant Systems for Early and Immediate Loading. Int J Dent 2021; 2021:6633804. [PMID: 33986808 PMCID: PMC8079217 DOI: 10.1155/2021/6633804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 04/01/2021] [Accepted: 04/15/2021] [Indexed: 11/23/2022] Open
Abstract
The removable platform switching technology (multiunit, Оn1) was tested intraoperatively using the passive placement technique as exemplified by a conical connection implant system, which makes it possible to visually control the placement of these platforms with respect to the alveolar bone in the correct orthopedic position. The technology is characterized by a rapid epithelialization of tissues around the base platform until the final integration of the implant, minimal trauma in the emergence profile zone, and an improved minimally invasive orthopedic protocol for working on a removable platform switching base.
Collapse
|
28
|
Abstract
Inlay-retained dental bridges can be a viable minimally invasive alternative when patients reject the idea of implant therapy or conventional retained full-coverage fixed dental prostheses, which require more tooth preparation. Inlay-retained dental bridges are indicated in patients with good oral hygiene, low susceptibility to caries, and a minimum coronal tooth height of 5 mm. The present study aims to evaluate, through the finite element method (FEM), the stability of these types of dental bridges and the stresses on the supporting teeth, under the action of masticatory forces. The analysis revealed the distribution of the load on the bridge elements and on the retainers, highlighting the areas of maximum pressure. The results of our study demonstrate that the stress determined by the loading force cannot cause damage to the prosthetic device or to abutment teeth. Thus, it can be considered an optimal economical solution for treating class III Kennedy edentation in young patients or as a provisional pre-implant rehabilitation option. However, special attention must be paid to its design, especially in the connection area between the bridge elements, because the connectors and the retainers represent the weakest parts.
Collapse
|
29
|
Orchestrating soft tissue integration at the transmucosal region of titanium implants. Acta Biomater 2021; 124:33-49. [PMID: 33444803 DOI: 10.1016/j.actbio.2021.01.001] [Citation(s) in RCA: 78] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 01/03/2021] [Accepted: 01/05/2021] [Indexed: 12/20/2022]
Abstract
Osseointegration at the bone-implant interface and soft tissue integration (STI) at the trans-mucosal region are crucial for the long-term success of dental implants, especially in compromised patient conditions. The STI quality of conventional smooth and bio-inert titanium-based implants is inferior to that of natural tissue (i.e. teeth), and hence various surface modifications have been suggested. This review article compares and contrasts the various modification strategies (physical, chemical and biological) utilized to enhance STI of Ti implants. It also details the STI challenges associated with conventional Ti-based implants, current surface modification strategies and cutting-edge nano-engineering solutions. The topographical, biological and therapeutic advances achievable via electrochemically anodized Ti implants with TiO2 nanotubes/nanopores are highlighted. Finally, the status and future directions of such nano-engineered implants is discussed, with emphasis on bridging the gap between research and clinical translation.
Collapse
|
30
|
Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation. Int J Mol Sci 2021; 22:ijms22020881. [PMID: 33477311 PMCID: PMC7830972 DOI: 10.3390/ijms22020881] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 12/21/2020] [Accepted: 01/14/2021] [Indexed: 01/02/2023] Open
Abstract
Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10−4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.
Collapse
|
31
|
Razali M, Ngeow WC, Omar RA, Chai WL. An In-Vitro Analysis of Peri-Implant Mucosal Seal Following Photofunctionalization of Zirconia Abutment Materials. Biomedicines 2021; 9:biomedicines9010078. [PMID: 33467486 PMCID: PMC7830892 DOI: 10.3390/biomedicines9010078] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2020] [Revised: 01/10/2021] [Accepted: 01/11/2021] [Indexed: 12/17/2022] Open
Abstract
The presence of epithelial and connective tissue attachment at the peri-implant-soft tissue region has been demonstrated to provide a biological barrier of the alveolar bone from the oral environment. This barrier can be improved via surface modification of implant abutment materials. The effect of photofunctionalization on creating a bioactive surface for the enhancement of the epithelial and connective tissue attachment of zirconia implant abutment's peri-implant mucosal interface using organotypic model has not been investigated. Therefore, this study aimed to evaluate the soft tissue seal around peri-implant mucosa and to understand the effect of photofunctionalization on the abutment materials. Three types of abutment materials were used in this study; yttria-stabilized zirconia (YSZ), alumina-toughened zirconia, and grade 2 commercially pure titanium (CPTi) which were divided into nontreated (N-Tx) and photofunctionalized group (UV-Tx). The three-dimensional peri-implant mucosal model was constructed using primary human gingival keratinocytes and fibroblasts co-cultured on the acellular dermal membrane. The biological seal was determined through the concentration of tritiated water permeating the material-soft tissue interface. The biological seal formed by the soft tissue in the N-Tx group was significantly reduced compared to the UV-treated group (p < 0.001), with YSZ exhibiting the lowest permeability among all materials. Photofunctionalization of implant abutment materials improved the biological seal of the surrounding soft tissue peri-implant interface.
Collapse
Affiliation(s)
- Masfueh Razali
- Department of Restorative Dentistry, Faculty of Dentistry, Universiti Kebangsaan Malaysia, Kuala Lumpur 50300, Malaysia
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur 50603, Malaysia;
- Correspondence: (M.R.); (W.L.C.); Tel.: +603-92897745 (M.R.); +603-79674548 (W.L.C.)
| | - Wei Cheong Ngeow
- Department of Oral and Maxillofacial Clinical Sciences, Faculty of Dentistry, University of Malaya, Kuala Lumpur 50603, Malaysia;
| | - Ros Anita Omar
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur 50603, Malaysia;
| | - Wen Lin Chai
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur 50603, Malaysia;
- Correspondence: (M.R.); (W.L.C.); Tel.: +603-92897745 (M.R.); +603-79674548 (W.L.C.)
| |
Collapse
|
32
|
Differences in the progression of experimental peri-implantitis depending on the implant to abutment connection. Clin Oral Investig 2020; 25:3577-3587. [PMID: 33179178 DOI: 10.1007/s00784-020-03680-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 11/04/2020] [Indexed: 01/28/2023]
Abstract
OBJECTIVES The aim was to evaluate the rate of bone loss progression during experimentally induced peri-implantitis using two different implant-abutment connections in implants with identical surface topography. MATERIAL AND METHODS Forty-eight Regular Neck tissue-level SLA implants with a matching implant to abutment connection (TL) and 36 bone-level SLA implants with a switching platform implant to abutment connection (BL) were subjected to experimental peri-implantitis in two independent in vivo pre-clinical investigations. Experimental peri-implantitis was induced by means of silk ligatures during 3 months (induction phase), and followed for one extra month without ligatures (progression phase). Radiographic and clinical outcomes were evaluated longitudinally along both studies and subsequently compared between experiments. RESULTS During the induction phase, radiographic bone loss was significantly higher in implants with matched abutments compared with those with platform switching connections (2.65 ± 0.66 mm vs 0.84 ± 0.16 mm, respectively, p = 0.001). During the progression phase, both types of implant-abutment connection exhibited similar rates of radiographic bone loss. Similar outcomes were observed clinically. CONCLUSIONS A platform switching connection resulted in a more benign development of peri-implantitis during the experimental induction phase of the disease. These differences, however, disappeared once the ligatures were removed (progression phase). CLINICAL RELEVANCE Influence of the implant-abutment connection in peri-implantitis progression may be relevant when considering implant selection in the moment of placement. In this sense, platform switching abutment demonstrated less peri-implantitis development when compared to implant matching connection.
Collapse
|
33
|
The Effect of Different Cleaning Protocols of Polymer-Based Prosthetic Materials on the Behavior of Human Gingival Fibroblasts. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17217753. [PMID: 33114133 PMCID: PMC7660342 DOI: 10.3390/ijerph17217753] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 10/19/2020] [Accepted: 10/20/2020] [Indexed: 12/16/2022]
Abstract
Dental implant abutment and prosthetic materials, their surface treatment, and cleaning modalities are important factors for the formation of a peri-implant soft tissue seal and long-term stability of bone around the implant. This study aimed to investigate the influence of a polymeric material surface cleaning method on the surface roughness, water contact angle, and human gingival fibroblasts (HGF) proliferation. Polymeric materials tested: two types of milled polymethylmethacrylate (PMMA-Ker and PMMA-Bre), three-dimensionally (3D) printed polymethylmethacrylate (PMMA-3D), polyetheretherketone (PEEK), and polyetherketoneketone (PEKK). Titanium (Ti) and zirconia oxide ceramics (ZrO-HT) were used as positive controls. A conventional surface cleaning protocol (CCP) was compared to a multi-step research cleaning method (RCP). Application of the RCP method allowed to reduce Sa values in all groups from 0.14-0.28 µm to 0.08-0.17 µm (p < 0.05 in PMMA-Ker and PEEK groups). Moreover, the water contact angle increased in all groups from 74-91° to 83-101° (p < 0.05 in the PEKK group), except ZrO-HT-it was reduced from 98.7 ± 4.5° to 69.9 ± 6.4° (p < 0.05). CCP resulted in higher variability of HGF viability after 48 and 72 h. RCP application led to higher HGF viability in PMMA-3D and PEKK groups after 48 h, but lower for the PMMA-Ker group (p < 0.05). After 72 h, no significant differences in HGF viability between both cleaning methods were observed. It can be concluded that the cleaning method of the polymeric materials affected surface roughness, contact angle, and HGF viability at 48 h.
Collapse
|
34
|
Borie M, Lecloux G, Bosshardt D, Barrantes A, Haugen HJ, Lambert F, Bacevic M. Peri-implant soft tissue integration in humans - influence of materials: A study protocol for a randomised controlled trial and a pilot study results. Contemp Clin Trials Commun 2020; 19:100643. [PMID: 33083628 PMCID: PMC7554019 DOI: 10.1016/j.conctc.2020.100643] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 07/15/2020] [Accepted: 08/09/2020] [Indexed: 11/25/2022] Open
Abstract
Background Recently, there has been a growing interest in mucointegration as the formation of an early and long-standing soft tissue barrier seems essential for both the initial healing and long-term implant survival. Aim To develop an experimental method to characterize the mucointegration of different transgingival materials (titanium (Ti), polyetheretherketone (PEEK), polymethylmethacrylate (PMMA), zirconia (Zi), polymer infiltrated ceramic network (PICN), cobalt-chrome (Co–Cr), and lithium disilicate (LD)) in a human model. Methods The study is designed as a multi-part randomized controlled clinical trial. Ninety bone level Straumann implants will randomly receive an experimental, custom-made abutment to allow for the removal of the abutment together with the surrounding soft tissues using a punch biopsy device at 8 weeks of healing (10 per material). The specimens will be further processed for non‐decalcified histology, followed by histomorphometric analysis. The same protocol will be used for additional 90 implants-abutments, but during harvesting, soft tissues will be separated from the abutment and processed for immunohistochemistry in order to study tissue inflammation and vascularization, while the abutments will undergo SEM analysis. Additionally, in vitro analyses, including SEM and profilometry, will be performed in order to characterize surface topography of all experimental materials. Conclusion The limited number of pilot samples presented herein indicate that the use of custom-made abutments in humans is a reproducible method to study peri-implant soft tissue integration. This further intensifies the rationale to compare different abutment materials, used as transgingival components in daily practice, under the same conditions.
Collapse
Affiliation(s)
- Manon Borie
- Department of Periodontology and Oral Surgery, University Hospital of Liège, Belgium
| | - Geoffrey Lecloux
- Department of Periodontology and Oral Surgery, University Hospital of Liège, Belgium
| | - Dieter Bosshardt
- Robert K. Schenk Laboratory of Oral Histology, School of Dental Medicine, University of Bern, Switzerland
| | - Alejandro Barrantes
- Department of Biomaterials, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Norway
| | - Håvard Jostein Haugen
- Department of Biomaterials, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Norway
| | - France Lambert
- Dental Biomaterials Research Unit, Faculty of Medicine, University of Liège, Belgium; Department of Periodontology and Oral Surgery, University Hospital of Liège, Belgium
| | - Miljana Bacevic
- Dental Biomaterials Research Unit, Faculty of Medicine, University of Liège, Belgium
| |
Collapse
|
35
|
Herrmann H, Kern J, Kern T, Lautensack J, Conrads G, Wolfart S. Early and mature biofilm on four different dental implant materials: An in vivo human study. Clin Oral Implants Res 2020; 31:1094-1104. [DOI: 10.1111/clr.13656] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 08/13/2020] [Accepted: 08/13/2020] [Indexed: 12/17/2022]
Affiliation(s)
- Henrike Herrmann
- Department of Prosthodontics and Biomaterials Center of Implantology Medical Faculty RWTH Aachen University Aachen Germany
| | - Jaana‐Sophia Kern
- Department of Prosthodontics and Biomaterials Center of Implantology Medical Faculty RWTH Aachen University Aachen Germany
| | - Thomas Kern
- Department of Prosthodontics and Biomaterials Center of Implantology Medical Faculty RWTH Aachen University Aachen Germany
| | - Julia Lautensack
- Department of Prosthodontics and Biomaterials Center of Implantology Medical Faculty RWTH Aachen University Aachen Germany
| | - Georg Conrads
- Division of Oral Microbiology and Immunology Medical Faculty RWTH Aachen University Aachen Germany
| | - Stefan Wolfart
- Department of Prosthodontics and Biomaterials Center of Implantology Medical Faculty RWTH Aachen University Aachen Germany
| |
Collapse
|
36
|
Cosola S, Marconcini S, Boccuzzi M, Menchini Fabris GB, Covani U, Peñarrocha-Diago M, Peñarrocha-Oltra D. Radiological Outcomes of Bone-Level and Tissue-Level Dental Implants: Systematic Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17186920. [PMID: 32971869 PMCID: PMC7557536 DOI: 10.3390/ijerph17186920] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 08/31/2020] [Accepted: 09/09/2020] [Indexed: 12/14/2022]
Abstract
Background: to assess the radiological marginal bone loss between bone-level or tissue-level dental implants through a systematic review of literature until September 2019. Methods: MEDLINE, Embase and other database were searched by two independent authors including only English articles. Results: The search provided 1028 records and, after removing the duplicates through titles and abstracts screening, 45 full-text articles were assessed for eligibility. For qualitative analysis 20 articles were included, 17 articles of them for quantitative analysis counting a total of 1161 patients (mean age 54.4 years) and 2933 implants, 1427 inserted at Tissue-level (TL) and 1506 inserted at Bone-level (BL). The survival rate and the success rate were more than 90%, except for 2 studies with a success rate of 88% and 86.2%. No studies reported any differences between groups in term of success and survival rates. Three studies showed that BL-implants had statistically less marginal bone loss (p < 0.05). Only one study reported statistically less marginal bone loss in TL-implants (p < 0.05). Conclusion: In the most part of the studies, differences between implant types in marginal bone loss were not statistically significant after a variable period of follow-up ranged between 1 and 5 years.
Collapse
Affiliation(s)
- Saverio Cosola
- Oral Surgery Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 13, 46010 Valencia, Spain; (M.P.-D.); (D.P.-O.)
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
- Correspondence:
| | - Simone Marconcini
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
| | - Michela Boccuzzi
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
| | - Giovanni Battista Menchini Fabris
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
- Department of Stomatology, University of Studies Guglielmo Marconi, 44, 00193 Roma, Italy
| | - Ugo Covani
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
| | - Miguel Peñarrocha-Diago
- Oral Surgery Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 13, 46010 Valencia, Spain; (M.P.-D.); (D.P.-O.)
| | - David Peñarrocha-Oltra
- Oral Surgery Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 13, 46010 Valencia, Spain; (M.P.-D.); (D.P.-O.)
| |
Collapse
|
37
|
Bollain J, Pulcini A, Sanz-Sánchez I, Figuero E, Alonso B, Sanz M, Herrera D. Efficacy of a 0.03% chlorhexidine and 0.05% cetylpyridinium chloride mouth rinse in reducing inflammation around the teeth and implants: a randomized clinical trial. Clin Oral Investig 2020; 25:1729-1741. [PMID: 32737664 DOI: 10.1007/s00784-020-03474-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 07/24/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To evaluate the efficacy of a 0.03% chlorhexidine (CHX) and 0.05% cetylpyridinium chloride (CPC) mouth rinse, as an adjunct to professional plaque removal (PPR) and mechanical hygiene, in the treatment of peri-implant mucositis (PiM) and gingivitis. MATERIAL AND METHODS Patients displaying PiM in, at least, one implant were included in this randomized, double-blinded, clinical trial. Subjects received PPR (at baseline and 6-month visits) and were instructed to rinse, twice daily, during 1 year with the tested mouth rinse or a placebo. Clinical and patient-reported outcomes were recorded at baseline and 6 and 12 months. RESULTS Fifty-four patients were included in the study and 46 attended the final visit. In the teeth and implants with inflammation, a higher reduction in BOP was observed in the test group. Statistically significant differences between groups were only observed in the lingual sites of the teeth with gingivitis (mean difference = 11.96%; 95% confidence interval [1.09; 22.83]; p = 0.03). Overall, compliance and satisfaction were good, even though staining were higher for the test group (p < 0.05). CONCLUSIONS The combined use of mechanical debridement with a 0.03% CHX and 0.05% CPC mouth rinse may have adjunctive benefits in the management of gingivitis, and it is associated with a higher degree of staining. CLINICAL RELEVANCE The control of gingivitis can be improved, after professional mechanical debridement, with toothbrushing and the supplementary use of a 0.03% CHX and 0.05% CPC mouth rinse at home. CLINICAL TRIAL REGISTRATION NUMBER NCT03533166.
Collapse
Affiliation(s)
- Juan Bollain
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| | - Alberto Pulcini
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| | - Ignacio Sanz-Sánchez
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| | - Elena Figuero
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain. .,Department of Dental Clinical Specialties, Faculty of Dentistry, Complutense University of Madrid, Plaza de Ramón y Cajal, s/n, 28040, Madrid, Spain.
| | - Bettina Alonso
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| | - Mariano Sanz
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| | - David Herrera
- ETEP (Etiology and Therapy of Periodontal and Peri-implant Diseases) Research Group, Faculty of Dentistry, University Complutense of Madrid, Madrid, Spain
| |
Collapse
|
38
|
Rivara F, Macaluso GM, Toffoli A, Calciolari E, Goldoni M, Lumetti S. The effect of a 2-mm inter-implant distance on esthetic outcomes in immediately non-occlusally loaded platform shifted implants in healed ridges: 12-month results of a randomized clinical trial. Clin Implant Dent Relat Res 2020; 22:486-496. [PMID: 32633040 DOI: 10.1111/cid.12926] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 05/09/2020] [Accepted: 05/14/2020] [Indexed: 11/30/2022]
Abstract
BACKGROUND Three millimeter is considered as the minimum distance to obtain soft and bone tissue stability in case of adjacent implants. The possibility to preserve peri-implant bone level using a platform switching connection has questioned this concept. PURPOSE The study evaluates soft tissue maintenance and marginal bone stability around implants, placed at 2 or 3 mm of distance. MATERIALS AND METHODS Thirty patients received two immediately loaded implants either at 2-mm (test) or at 3-mm (control) of distance in the premolar area. Soft tissue esthetics (papilla height and fill, keratinized tissue, recession) and radiographic peri-implant bone level changes were measured at 3, 6, and 12 months. RESULTS No significant differences between the two groups were detected neither for all soft tissue esthetic outcomes nor for bone level modifications up to 12 months. CONCLUSION The results suggested that up to 12 months post-loading, both 2- and 3-mm inter-distance platform-switched implants in healed site, supported adequate esthetic outcomes and peri-implant bone stability.
Collapse
Affiliation(s)
- Federico Rivara
- Center of Dental Medicine, University of Parma, Parma, Italy.,Department of Medicine and Surgery, University of Parma, Parma, Italy
| | - Guido Maria Macaluso
- Center of Dental Medicine, University of Parma, Parma, Italy.,Department of Medicine and Surgery, University of Parma, Parma, Italy
| | - Andrea Toffoli
- Center of Dental Medicine, University of Parma, Parma, Italy.,Department of Medicine and Surgery, University of Parma, Parma, Italy
| | - Elena Calciolari
- Center of Dental Medicine, University of Parma, Parma, Italy.,Department of Medicine and Surgery, University of Parma, Parma, Italy.,Center for Oral Clinical Research and Centre for Oral Immunobiology and Regenerative Medicine, Institute of Dentistry, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, UK
| | - Matteo Goldoni
- Department of Medicine and Surgery, University of Parma, Parma, Italy
| | - Simone Lumetti
- Center of Dental Medicine, University of Parma, Parma, Italy.,Department of Medicine and Surgery, University of Parma, Parma, Italy
| |
Collapse
|
39
|
AL‐Rabab'ah MA, AlTarawneh S, Jarad FD, Devlin H. Methodological Quality of Systematic Reviews Relating to Performance of All‐Ceramic Implant Abutments, Frameworks, and Restorations. J Prosthodont 2020; 30:36-46. [DOI: 10.1111/jopr.13206] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 05/26/2020] [Accepted: 05/27/2020] [Indexed: 01/07/2023] Open
Affiliation(s)
- Mohammad A. AL‐Rabab'ah
- Department of Conservative Dentistry, School of Dentistry The University of Jordan Amman Jordan
- School of Dentistry University of Liverpool UK
- Division of Dentistry The University of Manchester UK
| | - Sandra AlTarawneh
- Department of Removable Prosthodontics, School of Dentistry The University of Jordan Amman Jordan
- Department of Restorative Dentistry UIC College of Dentistry Chicago IL
| | | | - Hugh Devlin
- Division of Dentistry The University of Manchester UK
| |
Collapse
|
40
|
Pamato S, Honório HM, da Costa JA, Traebert JL, Bonfante EA, Pereira JR. The influence of titanium base abutments on peri-implant soft tissue inflammatory parameters and marginal bone loss: A randomized clinical trial. Clin Implant Dent Relat Res 2020; 22:542-548. [PMID: 32441407 DOI: 10.1111/cid.12900] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 01/18/2020] [Accepted: 03/10/2020] [Indexed: 12/28/2022]
Abstract
BACKGROUND Some techniques in implant dentistry have been suggested that may potentially alter peri-implant soft and hard tissue parameters. PURPOSE To evaluate the peri-implant soft tissue inflammatory parameters and crestal bone loss around titanium base abutments. MATERIALS AND METHODS Fifty two implants were placed in 21 patients and restored by single crowns. Subjects were randomly allocated into two groups: cement-retained abutment (n = 24) and titanium base (n = 28). Peri-implant probing depth, and mesial and distal marginal bone loss (MBL) were evaluated at implant loading (T1), 6 and 12 months (T2 and T3, respectively). Peri-implant bleeding-on-probing was evaluated at T2 and T3. Two-way repeated measures analysis of variance, Tukey test, Man Whitney, and Pearson correlation were performed for statistical analysis at P < .05. RESULTS The mean difference of peri-implant MBL from implant installation to 12 months in function was 1.15 ± 0.82 mm for the cement-retained group, and 1.23 ± 0.79 mm for the titanium base group. No statistically significant difference was found between the two groups for clinical and radiographic peri-implant evaluation. CONCLUSIONS Titanium base abutments present no negative effect on peri-implant soft tissue and MBL. When used to support single crowns, both approaches performed likewise regarding clinical and radiographic parameters.
Collapse
Affiliation(s)
- Saulo Pamato
- Post-Graduate Program of Health Sciences, University of Southern Santa Catarina, Tubarão, Santa Catarina, Brazil
| | - Heitor Marques Honório
- Department of Pediatrics Dentistry, Orthodontics, and Public Health, Bauru School of Dentistry, University of São Paulo, Bauru Campus, São Paulo, Brazil
| | - Jorge Alexandre da Costa
- Department of Prosthodontics, University of Southern Santa Catarina, Tubarão, Santa Catarina, Brazil
| | - Jefferson Luiz Traebert
- Post-Graduate Program of Health Sciences, University of Southern Santa Catarina, Tubarão, Santa Catarina, Brazil
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru Campus, São Paulo, Brazil
| | - Jefferson Ricardo Pereira
- Post-Graduate Program of Health Sciences, University of Southern Santa Catarina, Tubarão, Santa Catarina, Brazil
| |
Collapse
|
41
|
Affiliation(s)
- Takao HANAWA
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
| |
Collapse
|
42
|
Salvi GE, Moëne R, Wallkamm B, Hicklin SP, Bischof M, Nedir R, Mombelli A, Sculean A. Clinical and radiographic changes at tissue level implants with either a machined or a modified transmucosal neck surface: A 3-year multicentre randomized controlled proof-of-concept study. J Clin Periodontol 2020; 47:500-508. [PMID: 31912523 DOI: 10.1111/jcpe.13249] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 12/03/2019] [Accepted: 01/04/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND Surface modification may yield enhanced soft tissue adhesion to transmucosal titanium implant necks. AIM To evaluate and compare changes in soft tissues around implants with a modified hydrophilic sandblasted and acid-etched neck (mSLA; test) to those with a machined neck (M; control). MATERIALS AND METHODS Implants with a diameter of 4.1 mm and a neck height of 1.8 mm were randomly inserted in healed sites with pristine bone of the posterior maxilla or mandible. The modified Sulcus Bleeding Index (mSBI) (primary outcome) was assessed at baseline (BL) and 6, 12 and 36 months. Secondary outcomes included the assessment of pocket probing depth (PPD), mucosal recession (REC) and clinical attachment level (CAL). Standardized radiographs were taken at time of implant placement, at BL and after 12 and 36 months. RESULTS Of the 43 randomized subjects, 38 (19 test and 19 controls) completed the 36-month follow-up. Implant survival rates amounted to 95.5% (test) and 100% (control) (p > .05). At 36 months, 77.6% of test implants and 78.9% of control implants were without any bleeding sites (mSBI = 0; p > .05). The 36-month success rate was 86.4% in the test and 85.7% in the control group, respectively (p > .05). At 36 months, the mean radiographic bone level change from BL was 0.33 ± 0.69 mm at test implants and 0.12 ± 0.3 mm at control implants (p > .05). CONCLUSION Tissue level implants with a hydrophilic mSLA transmucosal neck failed to yield clinical and radiographic benefits compared with implants with a machined neck up to 3 years.
Collapse
Affiliation(s)
- Giovanni E Salvi
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Raphaël Moëne
- Division of Periodontology, School of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Beat Wallkamm
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Private Practice, Langenthal, Switzerland
| | - Stefan P Hicklin
- Division of Fixed Prosthodontics and Biomaterials, School of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Mark Bischof
- Swiss Dental Clinics Group, Ardentis Clinique Dentaire, Lausanne, Switzerland
| | - Rabah Nedir
- Swiss Dental Clinics Group, Ardentis Clinique Dentaire, Lausanne, Switzerland
| | - Andrea Mombelli
- Division of Periodontology, School of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Anton Sculean
- Department of Periodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
43
|
Has zirconia made a material difference in implant prosthodontics? A review. Dent Mater 2020; 36:1-8. [DOI: 10.1016/j.dental.2019.08.100] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 08/19/2019] [Indexed: 12/17/2022]
|
44
|
Pulcini A, Bollaín J, Sanz-Sánchez I, Figuero E, Alonso B, Sanz M, Herrera D. Clinical effects of the adjunctive use of a 0.03% chlorhexidine and 0.05% cetylpyridinium chloride mouth rinse in the management of peri-implant diseases: A randomized clinical trial. J Clin Periodontol 2019; 46:342-353. [PMID: 30779246 DOI: 10.1111/jcpe.13088] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 02/01/2019] [Accepted: 02/13/2019] [Indexed: 12/17/2022]
Abstract
AIM To evaluate the efficacy of a 0.03% chlorhexidine and 0.05% cetylpyridinium chloride mouth rinse, as an adjunct to professionally and patient-administered mechanical plaque removal, in the treatment of peri-implant mucositis (PiM). MATERIAL AND METHODS Patients displaying PiM in, at least, one implant were included in this randomized, double-blinded, clinical trial. Subjects received professional prophylaxis (baseline and 6 months) and were instructed to regular oral hygiene practices and to rinse, twice daily, with the test or placebo mouth rinses, during one year. Clinical, radiographic and microbiological outcomes were evaluated at baseline, 6 and 12 months. Disease resolution was defined as absence of bleeding on probing (BOP). Data were analysed by repeated measures ANOVA, Student's t and chi-square tests. RESULTS Fifty-four patients were included and 46 attended the final visit (22 in control and 24 in test group). In the test group, there was a 24.49% greater reduction in BOP at the buccal sites (95% confidence interval [3.65-45.34%]; p = 0.002) than in controls. About 58.3% of test implants and 50% controls showed healthy peri-implant tissues at final visit (p > 0.05). CONCLUSIONS The use of the test mouth rinse demonstrated some adjunctive benefits in the treatment of PiM. Complete disease resolution could not be achieved in every case.
Collapse
Affiliation(s)
- Alberto Pulcini
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group, University Complutense, Madrid, Spain
| | - Juan Bollaín
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group, University Complutense, Madrid, Spain
| | - Ignacio Sanz-Sánchez
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group, University Complutense, Madrid, Spain
| | - Elena Figuero
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group, University Complutense, Madrid, Spain
| | - Bettina Alonso
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group, University Complutense, Madrid, Spain
| | - Mariano Sanz
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group, University Complutense, Madrid, Spain
| | - David Herrera
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group, University Complutense, Madrid, Spain
| |
Collapse
|
45
|
Omori Y, Lang NP, Botticelli D, Papageorgiou SN, Baba S. Biological and mechanical complications of angulated abutments connected to fixed dental prostheses: A systematic review with meta-analysis. J Oral Rehabil 2019; 47:101-111. [PMID: 31441527 DOI: 10.1111/joor.12877] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Revised: 08/08/2019] [Accepted: 08/18/2019] [Indexed: 02/06/2023]
Abstract
OBJECTIVES To evaluate the biological and mechanical complications of angulated abutments on full-arch and partial jaw rehabilitations with a follow-up for at least 1 year. METHODS Electronic search was carried out in MEDLINE, EMBASE and Web of Science. Studies published between January 2000 and January 2019 were included. The quality of the included studies was assessed. The data extraction was focused on implant loss, marginal bone loss and mechanical complications, and meta-analyses were performed for marginal bone loss, mechanical complications and implant failure. RESULTS Nine studies, three prospective and six retrospective cohort studies were included. They reported on 797 patients that received 4127 implants. The total number of abutments was 4079 of which 1673 were angulated, and 2406 were straight. All abutments were prefabricated. Angulated abutments were associated with increased implant failure rates (two studies; RR = 7.30; 95% CI = 2.79-19.08) and an effect that was both statistically significant (P < .001) and clinically relevant. Three studies reported differentiated data for mechanical and technical complications at 1 year of follow-up, being mostly related to the retention screw while screw fracture. Angulated abutments were associated with a statistically significant increase in MBL 1 year after insertion compared to straight abutments (three studies; MD = 0.08 mm; 95% CI = 0.01-0.14 mm; P = .02), which might be, however, clinically negligible. CONCLUSIONS The prosthetic complications such as screw loosening and abutment loosening were frequent. After 1 year of follow-up, implants supporting angulated abutments yielded significantly more marginal bone loss than those supporting straight abutments.
Collapse
Affiliation(s)
- Yuki Omori
- Department of Oral Implantology, Osaka Dental University, Osaka, Japan.,ARDEC Academy, Ariminum Odontologica, Rimini, Italy
| | - Niklaus P Lang
- School of Dental Medicine, University of Berne, Berne, Switzerland
| | | | - Spyridon N Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Shunsuke Baba
- Department of Oral Implantology, Osaka Dental University, Osaka, Japan
| |
Collapse
|
46
|
Littuma GJS, Sordi MB, Borges Curtarelli R, Aragonês Á, da Cruz ACC, Magini RS. Titanium coated with poly(lactic-co-glycolic) acid incorporating simvastatin: Biofunctionalization of dental prosthetic abutments. J Periodontal Res 2019; 55:116-124. [PMID: 31493346 DOI: 10.1111/jre.12695] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Revised: 07/19/2019] [Accepted: 08/13/2019] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To propose a biofunctionalized prosthetic abutment by analyzing physico-chemical and morphological properties, simvastatin (SIM) release, and biocompatibility of titanium (Ti) disks coated with poly(lactic-co-glycolic) acid (PLGA) incorporating SIM. METHODS Titanium disks (8 × 3 mm) were distributed into four groups: Ti: pure Ti; Ti + PLGA: Ti coated with PLGA; Ti + PLGA + SIM6%: Ti + PLGA with 6% SIM; and Ti + PLGA + SIM0.6%: Ti + PLGA incorporating 0.6% SIM. PLGA was prepared through chloroform evaporation technique. After complete dissolution of PLGA, SIM was diluted in the solution. Ti + PLGA, Ti + PLGA + SIM6%, and Ti + PLGA + SIM0.6% were dip coated with PLGA and PLGA + SIM, respectively. Samples were sterilized by ethylene oxide. For SIM release assay, disks were submerged in PBS, pH 7.4, 37°C, 30 rpm up to 600 hours. At different time intervals, SIM was quantified by spectrophotometry (238 nm). For characterization of the biomaterial components, it was performed Fourier-transform infrared spectroscopy, differential scanning calorimetry, scanning electron microscopy (SEM), optical profilometry, and atomic force microscopy. Biocompatibility analyses were performed by MTS colorimetric assay on murine fibroblasts L929, human gingival fibroblasts (HGFs), and stem cells from human exfoliated deciduous teeth (SHEDs). Absorbance was measured at 490 nm, and percentages of viable cells were calculated in relation to positive control (Ti). SEM images were obtained to verify cell adhesion and morphology. One-way ANOVA followed by Tukey's post hoc test was applied (P < 0.05) for statistical analyses. RESULTS SIM release was slow and continuous, reaching about 21% of the incorporated SIM after 600 hours. Topographical analyses revealed success in coating Ti disks with PLGA incorporating SIM. Regarding biocompatibility test, Ti + PLGA + SIM0.6% showed the highest percentage of L929 viability at days 3 and 7. There was no significant difference for Ti, Ti + PLGA, and Ti + PLGA + SIM0.6% groups on cell viability of both SHEDs and HGFs at days 3 and 7. SEM corroborates that SHEDs and HGFs were able to adhere and proliferate on Ti, Ti + PLGA, and Ti + PLGA + SIM0.6% surfaces. CONCLUSION A slow and controlled release of SIM was achieved, attributed to a diffusional mass transfer mechanism. Moreover, a homogenous coating topography was obtained. Additionally, 0.6% SIM incorporated into PLGA coating improved fibroblasts L929 viability compared to titanium or PLGA. Also, 0.6% SIM incorporated into PLGA promoted cell viability of about 100% for HGFs and approximately 150% for human mesenchymal stem cells. Therefore, this study allows to consider the use of PLGA-coated titanium incorporating SIM as a biofunctionalized abutment for dental implants.
Collapse
Affiliation(s)
- Gustavo J S Littuma
- Dentistry Post Graduation, Federal University of Santa Catarina, Florianópolis, Brazil
| | - Mariane B Sordi
- Dentistry Post Graduation, Federal University of Santa Catarina, Florianópolis, Brazil
| | | | | | - Ariadne C C da Cruz
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Brazil
| | - Ricardo S Magini
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis, Brazil
| |
Collapse
|
47
|
Hu M, Chen J, Pei X, Han J, Wang J. Network meta-analysis of survival rate and complications in implant-supported single crowns with different abutment materials. J Dent 2019; 88:103115. [PMID: 30986515 DOI: 10.1016/j.jdent.2019.04.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2019] [Revised: 04/04/2019] [Accepted: 04/11/2019] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVES To compare the survival rate of abutments, marginal bone loss and peri-implant soft tissue discoloration among implant-supported single crowns with different abutment materials. DATA Randomized controlled trials (RCTs), controlled clinical trials, and cohort studies of implant-supported single crowns with different dental abutment materials. SOURCES A systematic search was conducted by an electronic search in 6 databases without restrictions on September 16, 2018, complemented by a manual search. "Grey" literatures were also searched. STUDY SELECTION Of 3417 studies initially retrieved, thirteen were eligible for inclusion. After studies selected and data extraction, pair-wise and network meta-analyses were performed to analyze the survival rate of the abutment, the marginal bone loss and the soft tissue discoloration. The risk of bias was assessed based on the Cochrane guidelines, Newcastle-Ottawa scale, and funnel plots. Statistical heterogeneity, inconsistencies, and cumulative ranking were also evaluated. RESULTS Fourteen RCTs and nine non-RCTs were included. No significant differences was detected among titanium (Ti), zirconia (Zr), gold (Au), and alumina (Al) abutments in terms of survival rate (excluding Al < Ti (P < 0.05), marginal bone loss (excluding Zr < Ti (P < 0.05) and Au > Zr (P < 0.05)), or discoloration of peri-implant soft tissue. Additionally, Ti abutment had the highest cumulative ranking of survival rate (97.9%); Al abutment had the lowest marginal bone loss (81.4%) and Zr abutment had the least discoloration of peri-implant soft tissue (84.8%). CONCLUSIONS Ti abutment has a comparable survival rate with Zr, but better than Al. In addition, Zr abutment has a better effect in maintaining the marginal bone level, compared with Au and Ti. However, there was no difference in the discoloration of peri-implant soft tissue among Au, Ti, and Zr abutment. CLINICAL SIGNIFICANCE Based on the results of our network meta-analysis, Zr might be a recommended abutment material considering the clinical efficacy of implant-supported single crowns.
Collapse
Affiliation(s)
- Menglong Hu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, No. 14, Section 3, South Renmin Road, Chengdu, 610041, China; Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, Section 3, South Renmin Road, Chengdu, 610041, China
| | - Junyu Chen
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, No. 14, Section 3, South Renmin Road, Chengdu, 610041, China; Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, Section 3, South Renmin Road, Chengdu, 610041, China
| | - Xibo Pei
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, No. 14, Section 3, South Renmin Road, Chengdu, 610041, China; Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, Section 3, South Renmin Road, Chengdu, 610041, China
| | - Jianmin Han
- Dental Medical Devices Testing Center, Dental Materials Laboratory, Peking University School and Hospital of Stomatology, Beijing, 100081, China
| | - Jian Wang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, No. 14, Section 3, South Renmin Road, Chengdu, 610041, China; Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, No. 14, Section 3, South Renmin Road, Chengdu, 610041, China.
| |
Collapse
|
48
|
The Effect of Tapered Abutments on Marginal Bone Level: A Retrospective Cohort Study. J Clin Med 2019; 8:jcm8091305. [PMID: 31450607 PMCID: PMC6780335 DOI: 10.3390/jcm8091305] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 08/17/2019] [Accepted: 08/20/2019] [Indexed: 01/16/2023] Open
Abstract
Background: Early peri-implant bone loss has been associated to long-term implant-prosthetic failure. Different technical, surgical, and prosthetic techniques have been introduced to enhance the clinical outcome of dental implants in terms of crestal bone preservation. The aim of the present cohort study was to observe the mean marginal bone level around two-part implants with gingivally tapered abutments one year after loading. Methods: Mean marginal bone levels and change were computed following radiological calibration and linear measurement on standardized radiographs. Results: Twenty patients who met the inclusion criterion of having at least one implant with the tapered prosthetic connection were included in the study. The cumulative implant success rate was 100%, the average bone loss was −0.18 ± 0.72 mm, with the final bone level sitting above the implant platform most of the time (+1.16 ± 0.91 mm). Conclusion: The results of this cohort study suggested that implants with tapered abutments perform successfully one year after loading and that they are associated with excellent marginal bone preservation, thus suggesting that implant-connection macro-geometry might have a crucial role in dictating peri-implant bone levels.
Collapse
|
49
|
Abstract
Objective: This analysis discusses common problems with systematic reviews (SRs) and presents a novel solution, the structured critical analysis (SCA) that can be incorporated into a SR or used as an alternative literature review design.Methods: A cross-sectional survey of current SRs related to interdisciplinary restorative dentistry was obtained by evaluating 100 current SRs for their self-reported methodological quality and its effect on scientific validity.Results: The preferred reporting items for systematic reviews and meta-analyses protocol (PRISMA) was used in 99/100 SRs, but only 8/100 reported a low risk of bias. High statistical heterogeneity precluding meta-analysis was found in 44/100 SRs. Only 94 paragraphs/100 SRs provided critical analysis.Discussion: Significant problems were found with current SRs that can compromise their reliability as the premier level of evidence for clinical science research. The reader must be aware of these deficiencies to correctly interpret the SR and cannot rely on the format alone.
Collapse
|
50
|
Schwarz F, Messias A, Sanz-Sánchez I, Carrillo de Albornoz A, Nicolau P, Taylor T, Beuer F, Schär A, Sader R, Guerra F, Sanz M. Influence of implant neck and abutment characteristics on peri-implant tissue health and stability. Oral reconstruction foundation consensus report. Clin Oral Implants Res 2019; 30:588-593. [PMID: 31006157 DOI: 10.1111/clr.13439] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Accepted: 04/11/2019] [Indexed: 11/27/2022]
Abstract
OBJECTIVE The aim of this consensus meeting was to assess the influence of implant neck and abutment characteristics on peri-implant tissue health and stability. MATERIAL AND METHODS Group and plenary discussions were based on two systematic reviews focusing on the effect of titanium implants with different collar designs/surface modifications and the abutment material on the stability of marginal bone levels (MBLs), peri-implant health, and survival rates. RESULTS The changes in MBLs were not influenced by the abutment material and were also similar at one- and two-piece implants after one year of loading. Rough collar implants improved MBLs in comparison to machined collar implants. Additional modifications of the collar had no beneficial clinical effect on MBLs. Titanium abutments were associated with significantly higher increases in bleeding on probing when compared with zirconia abutments. CONCLUSION MBLs are mainly influenced by the microstructure (i.e., rough surfaced) of the implant neck. Consensus statements and specific recommendations for future research were elaborated during the consensus meeting.
Collapse
Affiliation(s)
- Frank Schwarz
- Department of Oral Surgery and Implantology, Carolinum, Johann Wolfgang Goethe-University, Frankfurt, Germany
| | - Ana Messias
- Department of Dentistry, Faculdade de Medicina da Universidade de Coimbra, Coimbra, Portugal
| | | | | | - Pedro Nicolau
- Department of Dentistry, Faculdade de Medicina da Universidade de Coimbra, Coimbra, Portugal
| | - Tom Taylor
- Department of Reconstructive Sciences, University of Connecticut School of Dental Medicine, Farmington, Connecticut
| | - Florian Beuer
- Department of Prosthodontics, Charité University Medicine, Berlin, Germany
| | - Alex Schär
- Oral Reconstruction Foundation, Basel, Switzerland
| | - Robert Sader
- Department for Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Medical Center of the Goethe University, Frankfurt, Germany
| | - Fernando Guerra
- Department of Dentistry, Faculdade de Medicina da Universidade de Coimbra, Coimbra, Portugal
| | - Mariano Sanz
- Section of Graduate Periodontology, University Complutense, Madrid, Spain
| |
Collapse
|