1
|
Wang F, Chen X, Roelfsema PR. Comparison of electrical microstimulation artifact removal methods for high-channel-count prostheses. J Neurosci Methods 2024; 408:110169. [PMID: 38782123 DOI: 10.1016/j.jneumeth.2024.110169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 04/15/2024] [Accepted: 05/17/2024] [Indexed: 05/25/2024]
Abstract
BACKGROUND Neuroprostheses are used to electrically stimulate the brain, modulate neural activity and restore sensory and motor function following injury or disease, such as blindness, paralysis, and other movement and psychiatric disorders. Recordings are often made simultaneously with stimulation, allowing the monitoring of neural signals and closed-loop control of devices. However, stimulation-evoked artifacts may obscure neural activity, particularly when stimulation and recording sites are nearby. Several methods have been developed to remove stimulation artifacts, but it remains challenging to validate and compare these methods because the 'ground-truth' of the neuronal signals may be contaminated by artifacts. NEW METHOD Here, we delivered stimulation to the visual cortex via a high-channel-count prosthesis while recording neuronal activity and stimulation artifacts. We quantified the waveforms and temporal properties of stimulation artifacts from the cortical visual prosthesis (CVP) and used them to build a dataset, in which we simulated the neuronal activity and the stimulation artifacts. We illustrate how to use the simulated data to evaluate the performance of six software-based artifact removal methods (Template subtraction, Linear interpolation, Polynomial fitting, Exponential fitting, SALPA and ERAASR) in a CVP application scenario. RESULTS We here focused on stimulation artifacts caused by electrical stimulation through a high-channel-count cortical prosthesis device. We find that the Polynomial fitting and Exponential fitting methods outperform the other methods in recovering spikes and multi-unit activity. Linear interpolation and Template subtraction recovered the local-field potentials. CONCLUSION Polynomial fitting and Exponential fitting provided a good trade-off between the quality of the recovery of spikes and multi-unit activity (MUA) and the computational complexity for a cortical prosthesis.
Collapse
Affiliation(s)
- Feng Wang
- Department of Vision & Cognition, Netherlands Institute for Neuroscience (KNAW), Amsterdam 1105 BA, the Netherlands.
| | - Xing Chen
- Department of Ophthalmology, University of Pittsburgh School of Medicine, 203 Lothrop St, Pittsburgh, PA 15213, US.
| | - Pieter R Roelfsema
- Department of Vision & Cognition, Netherlands Institute for Neuroscience (KNAW), Amsterdam 1105 BA, the Netherlands; Department of Ophthalmology, University of Pittsburgh School of Medicine, 203 Lothrop St, Pittsburgh, PA 15213, US; Department of Integrative Neurophysiology, VU University, De Boelelaan 1085, Amsterdam 1081 HV, the Netherlands; Department of Neurosurgery, Academic Medical Centre, Postbus 22660, Amsterdam 1100 DD, the Netherlands; Laboratory of Visual Brain Therapy, Sorbonne Université, Institut National de la Santé et de la Recherche Médicale, Centre National de la Recherche Scientifique, Institut de la Vision, Paris F-75012, France.
| |
Collapse
|
2
|
Adkisson PW, Steinhardt CR, Fridman GY. Galvanic vs. pulsatile effects on decision-making networks: reshaping the neural activation landscape. J Neural Eng 2024; 21:10.1088/1741-2552/ad36e2. [PMID: 38518369 PMCID: PMC11877455 DOI: 10.1088/1741-2552/ad36e2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 03/22/2024] [Indexed: 03/24/2024]
Abstract
Objective. Primarily due to safety concerns, biphasic pulsatile stimulation (PS) is the present standard for electrical excitation of neural tissue with a diverse set of applications. While pulses have been shown to be effective to achieve functional outcomes, they have well-known deficits. Due to recent technical advances, galvanic stimulation (GS), delivery of current for extended periods of time (>1 s), has re-emerged as an alternative to PS.Approach. In this paper, we use a winner-take-all decision-making cortical network model to investigate differences between pulsatile and GS in the context of a perceptual decision-making task.Main results. Based on previous work, we hypothesized that GS would produce more spatiotemporally distributed, network-sensitive neural responses, while PS would produce highly synchronized activation of a limited group of neurons. Our results in-silico support these hypotheses for low-amplitude GS but deviate when galvanic amplitudes are large enough to directly activate or block nearby neurons.Significance. We conclude that with careful parametrization, GS could overcome some limitations of PS to deliver more naturalistic firing patterns in the group of targeted neurons.
Collapse
Affiliation(s)
- Paul W Adkisson
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America
| | - Cynthia R Steinhardt
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America
- Center for Theoretical Neuroscience, Columbia University, New York, NY 10027, United States of America
- Simons Society of Fellows, Simons Foundation, New York, NY 10010, United States of America
| | - Gene Y Fridman
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America
- Department of Otolaryngology Head and Neck Surgery, Johns Hopkins University, Baltimore, MD 21205, United States of America
| |
Collapse
|
3
|
Kumaravelu K, Grill WM. Neural mechanisms of the temporal response of cortical neurons to intracortical microstimulation. Brain Stimul 2024; 17:365-381. [PMID: 38492885 PMCID: PMC11090107 DOI: 10.1016/j.brs.2024.03.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 02/20/2024] [Accepted: 03/12/2024] [Indexed: 03/18/2024] Open
Abstract
BACKGROUND Intracortical microstimulation (ICMS) is used to map neuronal circuitry in the brain and restore lost sensory function, including vision, hearing, and somatosensation. The temporal response of cortical neurons to single pulse ICMS is remarkably stereotyped and comprises short latency excitation followed by prolonged inhibition and, in some cases, rebound excitation. However, the neural origin of the different response components to ICMS are poorly understood, and the interactions between the three response components during trains of ICMS pulses remains unclear. OBJECTIVE We used computational modeling to determine the mechanisms contributing to the temporal response to ICMS in model cortical neurons. METHODS We implemented a biophysically based computational model of a cortical column comprising neurons with realistic morphology and synapses and quantified the temporal response of cortical neurons to different ICMS protocols. We characterized the temporal responses to single pulse ICMS across stimulation intensities and inhibitory (GABA-B/GABA-A) synaptic strengths. To probe interactions between response components, we quantified the response to paired pulse ICMS at different inter-pulse intervals and the response to short trains at different stimulation frequencies. Finally, we evaluated the performance of biomimetic ICMS trains in evoking sustained neural responses. RESULTS Single pulse ICMS evoked short latency excitation followed by a period of inhibition, but model neurons did not exhibit post-inhibitory excitation. The strength of short latency excitation increased and the duration of inhibition increased with increased stimulation amplitude. Prolonged inhibition resulted from both after-hyperpolarization currents and GABA-B synaptic transmission. During the paired pulse protocol, the strength of short latency excitation evoked by a test pulse decreased marginally compared to those evoked by a single pulse for interpulse intervals (IPI) < 100 m s. Further, the duration of inhibition evoked by the test pulse was prolonged compared to single pulse for IPIs <50 m s and was not predicted by linear superposition of individual inhibitory responses. For IPIs>50 m s, the duration of inhibition evoked by the test pulse was comparable to those evoked by a single pulse. Short ICMS trains evoked repetitive excitatory responses against a background of inhibition. However, the strength of the repetitive excitatory response declined during ICMS at higher frequencies. Further, the duration of inhibition at the cessation of ICMS at higher frequencies was prolonged compared to the duration following a single pulse. Biomimetic pulse trains evoked comparable neural response between the onset and offset phases despite the presence of stimulation induced inhibition. CONCLUSIONS The cortical column model replicated the short latency excitation and long-lasting inhibitory components of the stereotyped neural response documented in experimental studies of ICMS. Both cellular and synaptic mechanisms influenced the response components generated by ICMS. The non-linear interactions between response components resulted in dynamic ICMS-evoked neural activity and may play an important role in mediating the ICMS-induced precepts.
Collapse
Affiliation(s)
| | - Warren M Grill
- Department of Biomedical Engineering, Duke University, Durham, NC, USA; Department of Electrical and Computer Engineering, Duke University, Durham, NC, USA; Department of Neurobiology, Duke University, Durham, NC, USA; Department of Neurosurgery, Duke University, Durham, NC, USA.
| |
Collapse
|
4
|
Burton A, Wang Z, Song D, Tran S, Hanna J, Ahmad D, Bakall J, Clausen D, Anderson J, Peralta R, Sandepudi K, Benedetto A, Yang E, Basrai D, Miller LE, Tresch MC, Gutruf P. Fully implanted battery-free high power platform for chronic spinal and muscular functional electrical stimulation. Nat Commun 2023; 14:7887. [PMID: 38036552 PMCID: PMC10689769 DOI: 10.1038/s41467-023-43669-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Accepted: 11/16/2023] [Indexed: 12/02/2023] Open
Abstract
Electrical stimulation of the neuromuscular system holds promise for both scientific and therapeutic biomedical applications. Supplying and maintaining the power necessary to drive stimulation chronically is a fundamental challenge in these applications, especially when high voltages or currents are required. Wireless systems, in which energy is supplied through near field power transfer, could eliminate complications caused by battery packs or external connections, but currently do not provide the harvested power and voltages required for applications such as muscle stimulation. Here, we introduce a passive resonator optimized power transfer design that overcomes these limitations, enabling voltage compliances of ± 20 V and power over 300 mW at device volumes of 0.2 cm2, thereby improving power transfer 500% over previous systems. We show that this improved performance enables multichannel, biphasic, current-controlled operation at clinically relevant voltage and current ranges with digital control and telemetry in freely behaving animals. Preliminary chronic results indicate that implanted devices remain operational over 6 weeks in both intact and spinal cord injured rats and are capable of producing fine control of spinal and muscle stimulation.
Collapse
Affiliation(s)
- Alex Burton
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Zhong Wang
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Dan Song
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Sam Tran
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Jessica Hanna
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Dhrubo Ahmad
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Jakob Bakall
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - David Clausen
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Jerry Anderson
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Roberto Peralta
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Kirtana Sandepudi
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Alex Benedetto
- Interdepartmental Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Ethan Yang
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Diya Basrai
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Lee E Miller
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
- Interdepartmental Neuroscience, Northwestern University, Chicago, IL, 60611, USA
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, 60611, USA
| | - Matthew C Tresch
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA.
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, 60611, USA.
- Shirley Ryan AbilityLab, Chicago, IL, 60611, USA.
| | - Philipp Gutruf
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA.
- Bio5 Institute and Department of Neurology, University of Arizona, Tucson, AZ, 85721, USA.
- Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ, 85721, USA.
| |
Collapse
|
5
|
Chen X, Wang F, Kooijmans R, Klink PC, Boehler C, Asplund M, Roelfsema PR. Chronic stability of a neuroprosthesis comprising multiple adjacent Utah arrays in monkeys. J Neural Eng 2023; 20:036039. [PMID: 37386891 PMCID: PMC7617000 DOI: 10.1088/1741-2552/ace07e] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 06/21/2023] [Indexed: 07/01/2023]
Abstract
Objective. Electrical stimulation of visual cortex via a neuroprosthesis induces the perception of dots of light ('phosphenes'), potentially allowing recognition of simple shapes even after decades of blindness. However, restoration of functional vision requires large numbers of electrodes, and chronic, clinical implantation of intracortical electrodes in the visual cortex has only been achieved using devices of up to 96 channels. We evaluated the efficacy and stability of a 1024-channel neuroprosthesis system in non-human primates (NHPs) over more than 3 years to assess its suitability for long-term vision restoration.Approach.We implanted 16 microelectrode arrays (Utah arrays) consisting of 8 × 8 electrodes with iridium oxide tips in the primary visual cortex (V1) and visual area 4 (V4) of two sighted macaques. We monitored the animals' health and measured electrode impedances and neuronal signal quality by calculating signal-to-noise ratios of visually driven neuronal activity, peak-to-peak voltages of the waveforms of action potentials, and the number of channels with high-amplitude signals. We delivered cortical microstimulation and determined the minimum current that could be perceived, monitoring the number of channels that successfully yielded phosphenes. We also examined the influence of the implant on a visual task after 2-3 years of implantation and determined the integrity of the brain tissue with a histological analysis 3-3.5 years post-implantation.Main results. The monkeys remained healthy throughout the implantation period and the device retained its mechanical integrity and electrical conductivity. However, we observed decreasing signal quality with time, declining numbers of phosphene-evoking electrodes, decreases in electrode impedances, and impaired performance on a visual task at visual field locations corresponding to implanted cortical regions. Current thresholds increased with time in one of the two animals. The histological analysis revealed encapsulation of arrays and cortical degeneration. Scanning electron microscopy on one array revealed degradation of IrOxcoating and higher impedances for electrodes with broken tips.Significance. Long-term implantation of a high-channel-count device in NHP visual cortex was accompanied by deformation of cortical tissue and decreased stimulation efficacy and signal quality over time. We conclude that improvements in device biocompatibility and/or refinement of implantation techniques are needed before future clinical use is feasible.
Collapse
Affiliation(s)
- Xing Chen
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47,1105 BA Amsterdam, The Netherlands
- Department of Ophthalmology, University of Pittsburgh School of Medicine, 1622 Locust St, Pittsburgh, PA 15219, United States of America
| | - Feng Wang
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47,1105 BA Amsterdam, The Netherlands
| | - Roxana Kooijmans
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47,1105 BA Amsterdam, The Netherlands
| | - Peter Christiaan Klink
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47,1105 BA Amsterdam, The Netherlands
- Experimental Psychology, Helmholtz Institute, Utrecht University, Utrecht, The Netherlands
- Laboratory of Visual Brain Therapy, Sorbonne Université, Institut National de la Santé et de la Recherche Médicale, Centre National de la Recherche Scientifique, Institut de la Vision, Paris F-75012, France
| | - Christian Boehler
- Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany
- BrainLinks-BrainTools Center, University of Freiburg, Georges-Köhler-Allee 201, 79110 Freiburg, Germany
| | - Maria Asplund
- Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany
- BrainLinks-BrainTools Center, University of Freiburg, Georges-Köhler-Allee 201, 79110 Freiburg, Germany
- Freiburg Institute for Advanced Studies (FRIAS), University of Freiburg, Albertstraße 19, 79104 Freiburg, Germany
- Chalmers University of Technology, Chalmersplatsen 4, 412 96 Gothenburg, Sweden
| | - Pieter Roelf Roelfsema
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47,1105 BA Amsterdam, The Netherlands
- Laboratory of Visual Brain Therapy, Sorbonne Université, Institut National de la Santé et de la Recherche Médicale, Centre National de la Recherche Scientifique, Institut de la Vision, Paris F-75012, France
- Department of Integrative Neurophysiology, VU University, De Boelelaan 1085, 1081 HV Amsterdam, The Netherlands
- Department of Psychiatry, Academic Medical Center, Postbus 22660, 1100 DD Amsterdam, The Netherlands
| |
Collapse
|
6
|
Urdaneta ME, Kunigk NG, Currlin S, Delgado F, Fried SI, Otto KJ. The Long-Term Stability of Intracortical Microstimulation and the Foreign Body Response Are Layer Dependent. Front Neurosci 2022; 16:908858. [PMID: 35769707 PMCID: PMC9234554 DOI: 10.3389/fnins.2022.908858] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 05/16/2022] [Indexed: 11/24/2022] Open
Abstract
Intracortical microstimulation (ICMS) of the somatosensory cortex (S1) can restore sensory function in patients with paralysis. Studies assessing the stability of ICMS have reported heterogeneous responses across electrodes and over time, potentially hindering the implementation and translatability of these technologies. The foreign body response (FBR) and the encapsulating glial scar have been associated with a decay in chronic performance of implanted electrodes. Moreover, the morphology, intrinsic properties, and function of cells vary across cortical layers, each potentially affecting the sensitivity to ICMS as well as the degree of the FBR across cortical depth. However, layer-by-layer comparisons of the long-term stability of ICMS as well as the extent of the astrocytic glial scar change across cortical layers have not been well explored. Here, we implanted silicon microelectrodes with electrode sites spanning all the layers of S1 in rats. Using a behavioral paradigm, we obtained ICMS detection thresholds from all cortical layers for up to 40 weeks. Our results showed that the sensitivity and long-term performance of ICMS is indeed layer dependent. Overall, detection thresholds decreased during the first 7 weeks post-implantation (WPI). This was followed by a period in which thresholds remained stable or increased depending on the interfacing layer: thresholds in L1 and L6 exhibited the most consistent increases over time, while those in L4 and L5 remained the most stable. Furthermore, histological investigation of the tissue surrounding the electrode showed a biological response of microglia and macrophages which peaked at L1, while the area of the astrocytic glial scar peaked at L2/3. Interestingly, the biological response of these FBR markers is less exacerbated at L4 and L5, suggesting a potential link between the FBR and the long-term stability of ICMS. These findings suggest that interfacing depth can play an important role in the design of chronically stable implantable microelectrodes.
Collapse
Affiliation(s)
- Morgan E. Urdaneta
- Department of Neuroscience, University of Florida, Gainesville, FL, United States
- *Correspondence: Morgan E. Urdaneta,
| | - Nicolas G. Kunigk
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States
| | - Seth Currlin
- Department of Neuroscience, University of Florida, Gainesville, FL, United States
| | - Francisco Delgado
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States
| | - Shelley I. Fried
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States
- Boston Veterans Affairs Healthcare System, Boston, MA, United States
| | - Kevin J. Otto
- Department of Neuroscience, University of Florida, Gainesville, FL, United States
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States
- Department of Materials Science and Engineering, University of Florida, Gainesville, FL, United States
- Department of Neurology, University of Florida, Gainesville, FL, United States
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, United States
- Kevin J. Otto,
| |
Collapse
|
7
|
Saldanha RL, Urdaneta ME, Otto KJ. The Role of Electrode-Site Placement in the Long-Term Stability of Intracortical Microstimulation. Front Neurosci 2021; 15:712578. [PMID: 34566563 PMCID: PMC8455844 DOI: 10.3389/fnins.2021.712578] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 08/19/2021] [Indexed: 11/13/2022] Open
Abstract
Intracortical microelectrodes are neuroprosthetic devices used in brain-machine interfaces to both record and stimulate neural activity in the brain. These technologies have been improved by advances in microfabrication, which have led to the creation of subcellular and high-density microelectrodes. The greater number of independent stimulation channels in these devices allows for improved neuromodulation selectivity, compared to single-site microelectrodes. Elements of electrode design such as electrode-site placement can influence the long-term performance of neuroprostheses. Previous studies have shown that electrode-sites placed on the edge of a planar microelectrode have greater chronic recording functionality than sites placed in the center. However, the effect of electrode-site placement on long-term intracortical microstimulation (ICMS) is still unknown. Here, we show that, in rats chronically implanted with custom-made planar silicon microelectrodes, electrode-sites on the tip of the device outperformed those on both the edge and center in terms of the effect per charge delivered, though there is still a slight advantage to using edge sites over center sites for ICMS. Longitudinal analysis of ICMS detection thresholds over a 16-week period revealed that while all sites followed a similar trend over time, the tip and edge sites consistently elicited the behavioral response with less charge compared to center sites. Furthermore, we quantified channel activity over time and found that edge sites remained more active than center sites over time, though the rate of decay of active sites for center and edge sites was comparable. Our results demonstrate that electrode-site placement plays an important role in the long-term stability of intracortical microstimulation and could be a potential factor to consider in the design of future intracortical electrodes.
Collapse
Affiliation(s)
- Ramya L Saldanha
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States
| | - Morgan E Urdaneta
- Department of Neuroscience, University of Florida, Gainesville, FL, United States
| | - Kevin J Otto
- J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States.,Department of Neuroscience, University of Florida, Gainesville, FL, United States.,Department of Materials Science and Engineering, University of Florida, Gainesville, FL, United States.,Department of Neurology, University of Florida, Gainesville, FL, United States.,Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, United States
| |
Collapse
|
8
|
Hughes CL, Flesher SN, Weiss JM, Downey JE, Boninger M, Collinger JL, Gaunt RA. Neural stimulation and recording performance in human sensorimotor cortex over 1500 days. J Neural Eng 2021; 18. [PMID: 34320481 DOI: 10.1088/1741-2552/ac18ad] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 07/28/2021] [Indexed: 01/12/2023]
Abstract
Objective.Intracortical microstimulation (ICMS) in somatosensory cortex can restore sensation to people with spinal cord injury. However, the recording quality from implanted microelectrodes can degrade over time and limitations in stimulation longevity have been considered a potential barrier to the clinical use of ICMS. Our objective was to evaluate recording stability of intracortical electrodes implanted in the motor and somatosensory cortex of one person. The electrodes in motor cortex had platinum tips and were not stimulated, while the electrodes in somatosensory cortex had sputtered iridium oxide film (SIROF) tips and were stimulated. Additionally, we measured how well ICMS was able to evoke sensations over time.Approach. We implanted microelectrode arrays with SIROF tips in the somatosensory cortex (SIROF-sensory) of a human participant with a cervical spinal cord injury. We regularly stimulated these electrodes to evoke tactile sensations on the hand. Here, we quantify the stability of these electrodes in comparison to non-stimulated platinum electrodes implanted in the motor cortex (platinum-motor) over 1500 days with recorded signal quality and electrode impedances. Additionally, we quantify the stability of ICMS-evoked sensations using detection thresholds.Main results. We found that recording quality, as assessed by the number of electrodes with high-amplitude waveforms (>100µV peak-to-peak), peak-to-peak voltage, noise, and signal-to-noise ratio, decreased over time on SIROF-sensory and platinum-motor electrodes. However, SIROF-sensory electrodes were more likely to continue to record high-amplitude signals than platinum-motor electrodes. Interestingly, the detection thresholds for stimulus-evoked sensations decreased over time from a median of 31.5μA at day 100-10.4μA at day 1500, with the largest changes occurring between day 100 and 500.Significance. These results demonstrate that ICMS in human somatosensory cortex can be provided over long periods of time without deleterious effects on recording or stimulation capabilities. In fact, the sensitivity to stimulation improved over time.
Collapse
Affiliation(s)
- Christopher L Hughes
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Sharlene N Flesher
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Jeffrey M Weiss
- Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - John E Downey
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, IL, United States of America
| | - Michael Boninger
- Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Jennifer L Collinger
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, United States of America
| | - Robert A Gaunt
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States of America.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, United States of America
| |
Collapse
|
9
|
Urdaneta ME, Kunigk NG, Delgado F, Fried SI, Otto KJ. Layer-specific parameters of intracortical microstimulation of the somatosensory cortex. J Neural Eng 2021; 18. [PMID: 33706301 DOI: 10.1088/1741-2552/abedde] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 03/11/2021] [Indexed: 12/25/2022]
Abstract
Objective. Intracortical microstimulation of the primary somatosensory cortex (S1) has shown great progress in restoring touch sensations to patients with paralysis. Stimulation parameters such as amplitude, phase duration, and frequency can influence the quality of the evoked percept as well as the amount of charge necessary to elicit a response. Previous studies in V1 and auditory cortices have shown that the behavioral responses to stimulation amplitude and phase duration change across cortical depth. However, this depth-dependent response has yet to be investigated in S1. Similarly, to our knowledge, the response to microstimulation frequency across cortical depth remains unexplored.Approach. To assess these questions, we implanted rats in S1 with a microelectrode with electrode-sites spanning all layers of the cortex. A conditioned avoidance behavioral paradigm was used to measure detection thresholds and responses to phase duration and frequency across cortical depth.Main results. Analogous to other cortical areas, the sensitivity to charge and strength-duration chronaxies in S1 varied across cortical layers. Likewise, the sensitivity to microstimulation frequency was layer dependent.Significance. These findings suggest that cortical depth can play an important role in the fine-tuning of stimulation parameters and in the design of intracortical neuroprostheses for clinical applications.
Collapse
Affiliation(s)
- Morgan E Urdaneta
- Department of Neuroscience, University of Florida, Gainesville, FL, United States of America
| | - Nicolas G Kunigk
- J. Crayton Pruitt Family Department of Biomedical Engineering University of Florida, Gainesville, FL, United States of America
| | - Francisco Delgado
- J. Crayton Pruitt Family Department of Biomedical Engineering University of Florida, Gainesville, FL, United States of America
| | - Shelley I Fried
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States of America.,Boston Veterans Affairs Healthcare System, Boston, MA, United States of America
| | - Kevin J Otto
- Department of Neuroscience, University of Florida, Gainesville, FL, United States of America.,J. Crayton Pruitt Family Department of Biomedical Engineering University of Florida, Gainesville, FL, United States of America.,Department of Materials Science and Engineering, University of Florida, Gainesville, FL, United States of America.,Department of Neurology, University of Florida, Gainesville, FL, United States of America.,Department of Electrical & Computer Engineering, University of Florida, Gainesville, FL, United States of America
| |
Collapse
|
10
|
Chen X, Wang F, Fernandez E, Roelfsema PR. Shape perception via a high-channel-count neuroprosthesis in monkey visual cortex. Science 2020; 370:1191-1196. [DOI: 10.1126/science.abd7435] [Citation(s) in RCA: 76] [Impact Index Per Article: 15.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 10/19/2020] [Indexed: 12/22/2022]
Abstract
Blindness affects 40 million people across the world. A neuroprosthesis could one day restore functional vision in the blind. We implanted a 1024-channel prosthesis in areas V1 and V4 of the visual cortex of monkeys and used electrical stimulation to elicit percepts of dots of light (called phosphenes) on hundreds of electrodes, the locations of which matched the receptive fields of the stimulated neurons. Activity in area V4 predicted phosphene percepts that were elicited in V1. We simultaneously stimulated multiple electrodes to impose visible patterns composed of a number of phosphenes. The monkeys immediately recognized them as simple shapes, motions, or letters. These results demonstrate the potential of electrical stimulation to restore functional, life-enhancing vision in the blind.
Collapse
Affiliation(s)
- Xing Chen
- Department of Vision & Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands
| | - Feng Wang
- Department of Vision & Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands
| | - Eduardo Fernandez
- Bioengineering Institute and CIBER-BBN, Miguel Hernández University of Elche, Elche, Spain
| | - Pieter R. Roelfsema
- Department of Vision & Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA Amsterdam, Netherlands
- Department of Integrative Neurophysiology, VU University, De Boelelaan 1085, 1081 HV Amsterdam, Netherlands
- Department of Psychiatry, Academic Medical Centre, Postbus 22660, 1100 DD Amsterdam, Netherlands
| |
Collapse
|
11
|
Boehler C, Carli S, Fadiga L, Stieglitz T, Asplund M. Tutorial: guidelines for standardized performance tests for electrodes intended for neural interfaces and bioelectronics. Nat Protoc 2020; 15:3557-3578. [DOI: 10.1038/s41596-020-0389-2] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/28/2020] [Indexed: 01/22/2023]
|
12
|
Urdaneta ME, Kunigk NG, Delgado F, Otto KJ. Somatosensory Cortex Microstimulation: Behavioral Effects of Phase Duration and Asymmetric Waveforms. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1809-1812. [PMID: 31946248 DOI: 10.1109/embc.2019.8856579] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Intracortical microstimulation has proven to be effective in a variety of sensory applications, such as returning touch percepts to paralyzed patients. The parameters of microstimulation play an important role in the perception quality of the stimulus. Eliciting naturalistic percepts is essential for the adaptability and functionality of this technology. Compared to the typical biphasic symmetric waveforms, asymmetric waveforms enhance activation selectivity by preferentially activating cell bodies. Behavioral studies have shown that asymmetric waveforms can elicit behavioral responses, but these require higher charges than typical symmetric waveforms. Here, we investigated the effects of phase duration and waveform asymmetry for somatosensory cortex intracortical microstimulation of freely-behaving rats. Detection thresholds were obtained using a conditioned avoidance behavioral paradigm. Our results indicate that phase duration has significant effects on threshold regardless of symmetry, polarity, and phase order of the waveform. Specifically, shorter phase durations tend to elicit lower behavioral thresholds. Analogous to studies in the auditory cortex, asymmetric waveforms in which the short pulse was cathodic were more effective than those with short-anodic pulses. With short phase durations, these short-cathodic waveforms are capable of evoking behavioral responses at low charges (<; 5 nC/Phase). Altogether, these results suggest the possibility of cell body selective microstimulation at safe thresholds, as well as the potential translatability of neuromodulation parameters across distinct sensory cortical areas.
Collapse
|
13
|
Sombeck JT, Miller LE. Short reaction times in response to multi-electrode intracortical microstimulation may provide a basis for rapid movement-related feedback. J Neural Eng 2019; 17:016013. [PMID: 31778982 PMCID: PMC7189902 DOI: 10.1088/1741-2552/ab5cf3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
OBJECTIVE Tetraplegic patients using brain-machine interfaces can make visually guided reaches with robotic arms. However, restoring proprioceptive feedback to these patients will be critical, as evidenced by the movement deficit in patients with proprioceptive loss. Proprioception is critical in large part because it provides faster feedback than vision. Intracortical microstimulation (ICMS) is a promising approach, but the ICMS-evoked reaction time (RT) is typically slower than that to natural proprioceptive and often even visual cues, implying that ICMS feedback may not be fast enough to guide movement. APPROACH For most sensory modalities, RT decreases with increased stimulus intensity. Thus, it may be that stimulation intensities beyond what has previously been used will result in faster RTs. To test this, we compared the RT to ICMS applied through multi-electrode arrays in area 2 of somatosensory cortex to that of mechanical and visual cues. MAIN RESULTS We found that the RT to single-electrode ICMS decreased with increased current, frequency, and train length. For 100 µA, 330 Hz stimulation, the highest single-electrode intensity we tested routinely, most electrodes resulted in RTs slower than the mechanical cue but slightly faster than the visual cue. While increasing the current beyond 100 µA resulted in faster RTs, sustained stimulation at this level may damage tissue. Alternatively, by stimulating through multiple electrodes (mICMS), a large amount of current can be injected while keeping that through each electrode at a safe level. We found that stimulation with at least 480 µA equally distributed over 16 electrodes could produce RTs as much as 20 ms faster than the mechanical cue, roughly the conduction delay to cortex from the periphery. SIGNIFICANCE These results suggest that mICMS may provide a means to supply rapid, movement-related feedback. Future neuroprosthetics may need spatiotemporally patterned mICMS to convey useful somatosensory information. Novelty & Significance Intracortical microstimulation (ICMS) is a promising approach for providing artificial somatosensation to patients with spinal cord injury or limb amputation, but in prior experiments, subjects have been unable to respond as quickly to it as to natural cues. We have investigated the use of multi-electrode stimulation (mICMS) and discovered that it can produce reaction times as fast or faster even than natural mechanical cues. Although our stimulus trains were not modulated in time, this result opens the door to more complex spatiotemporal patterns of mICMS that might be used to rapidly write in complex somatosensory information to the CNS.
Collapse
Affiliation(s)
- Joseph T Sombeck
- Department of Physiology, Northwestern University, Chicago, IL, United States of America. Department of Biomedical Engineering, Northwestern University, Evanston, IL, United States of America
| | | |
Collapse
|
14
|
Sound- and current-driven laminar profiles and their application method mimicking acoustic responses in the mouse auditory cortex in vivo. Brain Res 2019; 1721:146312. [PMID: 31323198 DOI: 10.1016/j.brainres.2019.146312] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Revised: 06/14/2019] [Accepted: 06/27/2019] [Indexed: 11/24/2022]
Abstract
The local application of electrical currents to the cortex is one of the most commonly used techniques to activate neurons, and this intracortical stimulation (ICS) could potentially lead to new types of neuroprosthetic devices that can be directly applied to the cortex. To identify whether ICS-activated circuits are physiological vs. profoundly artificial, it is necessary to record in vivo the responses of the same neuronal population to both natural sensory stimuli and artificial electric stimuli. However, few studies have extensively reported simultaneous electrophysiological recordings combined with ICS. Here, we evaluated the similarity between sound- and ICS-driven cortical response patterns in different cortical layers. In the mouse auditory cortex, we performed laminar recordings using 16-channel silicon electrodes and ICS using sharp glass-pipette electrodes containing biocytin for layer identification. In different cortical depths, short current pulses were delivered in vivo to mice under urethane anesthesia. For the recorded data, we mainly analyzed properties of local field potentials and current source densities (CSDs). We demonstrated that electrical stimulation evoked different excitation patterns according to the stimulated cortical layer; responses to electric stimuli in layer 4 were most likely to mimic acoustic responses. Next, we proposed a CSD-based stimulation method to artificially synthesize sound-driven responses, using an approximation method associated with a linear combination of CSD patterns electrically stimulated in the different cortical layers. The result indicates that synthesized responses were consistent with the canonical model of sound processing. Using these approaches, we provide a new technique in which natural sound-driven responses can be mimicked by well-designed computational stimulation pattern sequences in a layer-dependent manner. These findings may aid in the future development of an electrical stimulation methodology for a cortical prosthesis.
Collapse
|
15
|
Kirin SC, Yanagisawa T, Oshino S, Edakawa K, Tanaka M, Kishima H, Nishimura Y. Somatosensation Evoked by Cortical Surface Stimulation of the Human Primary Somatosensory Cortex. Front Neurosci 2019; 13:1019. [PMID: 31607854 PMCID: PMC6769168 DOI: 10.3389/fnins.2019.01019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Accepted: 09/09/2019] [Indexed: 11/13/2022] Open
Abstract
Electrical stimulation of the primary somatosensory cortex using intracranial electrodes is crucial for the evocation of artificial somatosensations, typically tactile sensations associated with specific regions of the body, in brain-machine interface (BMI) applications. The qualitative characteristics of these artificially evoked somatosensations has been well documented. As of yet, however, the quantitative aspects of these evoked somatosensations, that is to say the quantitative relationship between intensity of electrical stimulation and perceived intensity of the resultant somatosensation remains obscure. This study aimed to explore this quantitative relationship by surface electrical stimulation of the primary somatosensory cortex in two human participants undergoing electrocorticographic monitoring prior to surgical treatment of intractable epilepsy. Electrocorticogram electrodes on the primary somatosensory cortical surface were stimulated with varying current intensities, and a visual analogue scale was employed to provide a quantitative measure of intensity of the evoked sensations. Evoked sensations included those of the thumb, tongue, and hand. A clear linear relationship between current intensity and perceived intensity of sensation was observed. These findings provide novel insight into the quantitative nature of primary somatosensory cortex electrical stimulation-evoked sensation for development of somatosensory neuroprosthetics for clinical use.
Collapse
Affiliation(s)
- St. Clair Kirin
- Department of Developmental Physiology, National Institute for Physiological Sciences, Okazaki, Japan
- Department of Physiological Sciences, School of Life Sciences, The Graduate University for Advanced Studies (SOKENDAI), Hayama, Japan
| | - Takufumi Yanagisawa
- Department of Neurosurgery, Graduate School of Medicine Osaka University, Suita, Japan
- Center for Information and Neural Networks, National Institute of Information and Communications Technology, Suita, Japan
- Institute for Advanced Co-Creation Studies, Osaka University, Suita, Japan
- *Correspondence: Takufumi Yanagisawa, ;
| | - Satoru Oshino
- Department of Neurosurgery, Graduate School of Medicine Osaka University, Suita, Japan
| | - Kohtaroh Edakawa
- Department of Neurosurgery, Graduate School of Medicine Osaka University, Suita, Japan
| | - Masataka Tanaka
- Department of Neurosurgery, Graduate School of Medicine Osaka University, Suita, Japan
| | - Haruhiko Kishima
- Department of Neurosurgery, Graduate School of Medicine Osaka University, Suita, Japan
| | - Yukio Nishimura
- Department of Developmental Physiology, National Institute for Physiological Sciences, Okazaki, Japan
- Department of Physiological Sciences, School of Life Sciences, The Graduate University for Advanced Studies (SOKENDAI), Hayama, Japan
- Neural Prosthesis Project, Department of Dementia and Higher Brain Function, Tokyo Metropolitan Institute of Medical Science, Tokyo, Japan
- Yukio Nishimura,
| |
Collapse
|
16
|
Caldwell DJ, Cronin JA, Wu J, Weaver KE, Ko AL, Rao RPN, Ojemann JG. Direct stimulation of somatosensory cortex results in slower reaction times compared to peripheral touch in humans. Sci Rep 2019; 9:3292. [PMID: 30824821 PMCID: PMC6397274 DOI: 10.1038/s41598-019-38619-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Accepted: 01/04/2019] [Indexed: 01/13/2023] Open
Abstract
Direct cortical stimulation (DCS) of primary somatosensory cortex (S1) could help restore sensation and provide task-relevant feedback in a neuroprosthesis. However, the psychophysics of S1 DCS is poorly studied, including any comparison to cutaneous haptic stimulation. We compare the response times to DCS of human hand somatosensory cortex through electrocorticographic grids with response times to haptic stimuli delivered to the hand in four subjects. We found that subjects respond significantly slower to S1 DCS than to natural, haptic stimuli for a range of DCS train durations. Median response times for haptic stimulation varied from 198 ms to 313 ms, while median responses to reliably perceived DCS ranged from 254 ms for one subject, all the way to 528 ms for another. We discern no significant impact of learning or habituation through the analysis of blocked trials, and find no significant impact of cortical stimulation train duration on response times. Our results provide a realistic set of expectations for latencies with somatosensory DCS feedback for future neuroprosthetic applications and motivate the study of neural mechanisms underlying human perception of somatosensation via DCS.
Collapse
Affiliation(s)
- David J Caldwell
- Department of Bioengineering, University of Washington, Seattle, USA. .,Medical Scientist Training Program, University of Washington, Seattle, USA. .,National Science Foundation Center for Neurotechnology, Seattle, USA.
| | - Jeneva A Cronin
- Department of Bioengineering, University of Washington, Seattle, USA. .,National Science Foundation Center for Neurotechnology, Seattle, USA.
| | - Jing Wu
- Department of Bioengineering, University of Washington, Seattle, USA.,National Science Foundation Center for Neurotechnology, Seattle, USA
| | - Kurt E Weaver
- Department of Radiology, University of Washington, Seattle, USA.,National Science Foundation Center for Neurotechnology, Seattle, USA
| | - Andrew L Ko
- Department of Neurological Surgery, University of Washington, Seattle, USA.,National Science Foundation Center for Neurotechnology, Seattle, USA
| | - Rajesh P N Rao
- Department of Computer Science and Engineering, University of Washington, Seattle, USA.,National Science Foundation Center for Neurotechnology, Seattle, USA
| | - Jeffrey G Ojemann
- Department of Neurological Surgery, University of Washington, Seattle, USA.,National Science Foundation Center for Neurotechnology, Seattle, USA
| |
Collapse
|
17
|
Tanaka Y, Nomoto T, Shiki T, Sakata Y, Shimada Y, Hayashida Y, Yagi T. Focal activation of neuronal circuits induced by microstimulation in the visual cortex. J Neural Eng 2019; 16:036007. [PMID: 30818288 DOI: 10.1088/1741-2552/ab0b80] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Microstimulation to the cortical tissue applied with penetrating electrodes delivers current that spreads concentrically around the electrode tip and is known to evoke focal visual sensations, i.e. phosphenes. However, to date, there is no direct evidence depicting the spatiotemporal properties of neuronal activity induced immediately after microstimulation and how such activity drives the subsequent local cortical circuits. APPROACH In the present study, we imaged the spatiotemporal distribution of action potentials (APs) directly induced by microstimulation and the subsequent trans-synaptic signal propagation using a voltage-sensitive dye (VSD) and a calcium-sensitive dye (CaSD) in slice preparations of the mouse primary visual cortex. MAIN RESULTS The directly induced APs were confined to the close vicinity of the electrode tip, and the effective distance of excitation was proportional to the square root of the current intensity. The excitation around the electrode tip in layer IV mainly propagated to layer II/III to further induce the subsequent focal activation in downstream local cortical circuits. The extent of activation in the downstream circuits was restrained by competitive interactions between excitatory and inhibitory signals. Namely, the spread of the excitation to lateral neighbor neurons along the layer II/III was confined by the delayed inhibition that also spread laterally at a faster rate. SIGNIFICANCE These observations indicate that dynamic interactions between excitatory and inhibitory signals play a critical role in the focal activation of a cortical circuit in response to intracortical microstimulation and, therefore, in evoking a localized phosphene.
Collapse
Affiliation(s)
- Yuta Tanaka
- Division of Electrical, Electronic, and Information Engineering, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan
| | | | | | | | | | | | | |
Collapse
|
18
|
Voigt MB, Kral A. Cathodic-leading pulses are more effective than anodic-leading pulses in intracortical microstimulation of the auditory cortex. J Neural Eng 2019; 16:036002. [PMID: 30790776 DOI: 10.1088/1741-2552/ab0944] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE Intracortical microstimulation (ICMS) is widely used in neuroscientific research. Earlier work from our lab showed the possibility to combine ICMS with neuronal recordings on the same shank of multi-electrode arrays and consequently inside the same cortical column in vivo. The standard stimulus pulse shape for ICMS is a symmetric, biphasic current pulse. Here, we investigated the role of the leading-phase polarity (cathodic- versus anodic-leading) of such single ICMS pulses on the activation of the cortical network. APPROACH Local field potentials (LFPs) and multi-unit responses were recorded in the primary auditory cortex (A1) of adult guinea pigs (n = 15) under ketamine/xylazine anesthesia using linear multi-electrode arrays. Physiological responses of A1 were recorded during acoustic stimulation and ICMS. For the ICMS, the leading-phase polarity, the stimulated electrode and the stimulation current where varied systematically on any one of the 16 electrodes while recording at the same time with the 15 remaining electrodes. MAIN RESULTS Cathodic-leading ICMS consistently led to higher response amplitudes. In superficial cortical layers and for a given current amplitude, cathodic-leading and anodic-leading ICMS showed comparable activation patterns, while in deep layers only cathodic-leading ICMS reliably generated local neuronal activity. ICMS had a significantly smaller dynamic range than acoustic stimulation regardless of leading-phase polarity. SIGNIFICANCE The present study provides in vivo evidence for a differential neuronal activation mechanism of the different leading-phase polarities, with cathodic-leading stimulation being more effective, and suggests that the waveform of the stimulus should be considered systematically for cortical neuroprosthesis development.
Collapse
Affiliation(s)
- Mathias Benjamin Voigt
- Department of Experimental Otology, Institute of AudioNeuroTechnology (VIANNA), Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany. Cluster of Excellence 'Hearing4all', Hannover, Germany
| | | |
Collapse
|
19
|
Thyagarajan K, Fried SI. Micro-Coil Design Influences the Spatial Extent of Responses to Intracortical Magnetic Stimulation. IEEE Trans Biomed Eng 2018; 66:1680-1694. [PMID: 30369434 DOI: 10.1109/tbme.2018.2877713] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
OBJECTIVE Electrical stimulation via cortically implanted electrodes has been proposed to treat a wide range of neurological disorders. Effectiveness has been limited, however, in part due to the inability of conventional electrodes to activate specific types of neurons while avoiding other types. Recent demonstrations that magnetic stimulation from a micro-coil can selectively activate pyramidal neurons (PNs) while avoiding passing axons suggest the possibility that such an approach can overcome some this limitation and here we use computer simulations to explore how the micro-coil design influences the selectivity with which neurons are activated. METHODS A computational model was developed to compare the selectivity of magnetic stimulation induced by rectangular-, V-, and W-shaped coil designs. The more promising designs (V- and W-shapes) were fabricated for use in electrophysiological experiments including in vitro patch-clamp recording and calcium imaging (GCaMP6f) of mouse brain slices. RESULTS Both V- and W-shaped coils reliably activated layer 5 (L5) PNs but V-coils were more effective while W-coils were more selective. Activation thresholds with double-loop coils were approximately one-half those of single-loop coils. Calcium imaging revealed that both V- and W-coils better confine activation than electrodes. CONCLUSION Individual design features can influence both the strength as well as the selectivity of micro-coils and can be accurately predicted by computer simulations. SIGNIFICANCE Our results show that how coil design influences the response of cortical neurons to stimulation and are an important step toward the development of next-generation cortical prostheses.
Collapse
|
20
|
Lee SW, Fried SI. Enhanced Control of Cortical Pyramidal Neurons With Micromagnetic Stimulation. IEEE Trans Neural Syst Rehabil Eng 2017; 25:1375-1386. [PMID: 27893396 PMCID: PMC5498237 DOI: 10.1109/tnsre.2016.2631446] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Magnetic stimulation is less sensitive to the inflammatory reactions that plague conventional electrode-based cortical implants and therefore may be useful as a next-generation (implanted) cortical prosthetic. The fields arising from micro-coils are quite small however and thus, their ability to modulate cortical activity must first be established. Here, we show that layer V pyramidal neurons (PNs) can be strongly activated by micro-coil stimulation and further, the asymmetric fields arising from such coils do not simultaneously activate horizontally-oriented axon fibers, thus confining activation to a focal region around the coil. The spatially-narrow fields from micro-coils allowed the sensitivity of different regions within a single PN to be compared: while the proximal axon was most sensitive in naïve cells, repetitive stimulation over the apical dendrite led to a change in state of the neuron that reduced thresholds there to below those of the axon. Thus, our results raise the possibility that regardless of the mode of stimulation, penetration depths that target specific portions of the apical dendrite may actually be more effective than those that target Layer 6. Interestingly, the state change had similar properties to state changes described previously at the systems level, suggesting a possible neuronal mechanism underlying such responses.
Collapse
|
21
|
Klink PC, Dagnino B, Gariel-Mathis MA, Roelfsema PR. Distinct Feedforward and Feedback Effects of Microstimulation in Visual Cortex Reveal Neural Mechanisms of Texture Segregation. Neuron 2017. [PMID: 28625487 DOI: 10.1016/j.neuron.2017.05.033] [Citation(s) in RCA: 73] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The visual cortex is hierarchically organized, with low-level areas coding for simple features and higher areas for complex ones. Feedforward and feedback connections propagate information between areas in opposite directions, but their functional roles are only partially understood. We used electrical microstimulation to perturb the propagation of neuronal activity between areas V1 and V4 in monkeys performing a texture-segregation task. In both areas, microstimulation locally caused a brief phase of excitation, followed by inhibition. Both these effects propagated faithfully in the feedforward direction from V1 to V4. Stimulation of V4, however, caused little V1 excitation, but it did yield a delayed suppression during the late phase of visually driven activity. This suppression was pronounced for the V1 figure representation and weaker for background representations. Our results reveal functional differences between feedforward and feedback processing in texture segregation and suggest a specific modulating role for feedback connections in perceptual organization.
Collapse
Affiliation(s)
- P Christiaan Klink
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA, Amsterdam, the Netherlands; Department of Neuromodulation and Behaviour, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA, Amsterdam, the Netherlands; Department of Psychiatry, Academic Medical Center, University of Amsterdam, 1100 DD Amsterdam, the Netherlands; Department of Integrative Neurophysiology, Center for Neurogenomics and Cognitive Research, VU University, 1081 HV Amsterdam, the Netherlands
| | - Bruno Dagnino
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA, Amsterdam, the Netherlands
| | - Marie-Alice Gariel-Mathis
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA, Amsterdam, the Netherlands
| | - Pieter R Roelfsema
- Department of Vision and Cognition, Netherlands Institute for Neuroscience, Meibergdreef 47, 1105 BA, Amsterdam, the Netherlands; Department of Psychiatry, Academic Medical Center, University of Amsterdam, 1100 DD Amsterdam, the Netherlands; Department of Integrative Neurophysiology, Center for Neurogenomics and Cognitive Research, VU University, 1081 HV Amsterdam, the Netherlands.
| |
Collapse
|
22
|
Intracortical microstimulation differentially activates cortical layers based on stimulation depth. Brain Stimul 2017; 10:684-694. [DOI: 10.1016/j.brs.2017.02.009] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Revised: 01/23/2017] [Accepted: 02/24/2017] [Indexed: 12/22/2022] Open
|
23
|
Lee SW, Fallegger F, Casse BDF, Fried SI. Implantable microcoils for intracortical magnetic stimulation. SCIENCE ADVANCES 2016; 2:e1600889. [PMID: 27957537 PMCID: PMC5148213 DOI: 10.1126/sciadv.1600889] [Citation(s) in RCA: 85] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Accepted: 11/03/2016] [Indexed: 05/20/2023]
Abstract
Neural prostheses that stimulate the neocortex have the potential to treat a wide range of neurological disorders. However, the efficacy of electrode-based implants remains limited, with persistent challenges that include an inability to create precise patterns of neural activity as well as difficulties in maintaining response consistency over time. These problems arise from fundamental limitations of electrodes as well as their susceptibility to implantation and have proven difficult to overcome. Magnetic stimulation can address many of these limitations, but coils small enough to be implanted into the cortex were not thought strong enough to activate neurons. We describe a new microcoil design and demonstrate its effectiveness for both activating cortical neurons and driving behavioral responses. The stimulation of cortical pyramidal neurons in brain slices in vitro was reliable and could be confined to spatially narrow regions (<60 μm). The spatially asymmetric fields arising from the coil helped to avoid the simultaneous activation of passing axons. In vivo implantation was safe and resulted in consistent and predictable behavioral responses. The high permeability of magnetic fields to biological substances may yield another important advantage because it suggests that encapsulation and other adverse effects of implantation will not diminish coil performance over time, as happens to electrodes. These findings suggest that a coil-based implant might be a useful alternative to existing electrode-based devices. The enhanced selectivity of microcoil-based magnetic stimulation will be especially useful for visual prostheses as well as for many brain-computer interface applications that require precise activation of the cortex.
Collapse
Affiliation(s)
- Seung Woo Lee
- Boston Veterans Affairs Healthcare System, Boston, MA 02130, USA
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Florian Fallegger
- Palo Alto Research Center, a Xerox company, Palo Alto, CA 94304, USA
| | | | - Shelley I. Fried
- Boston Veterans Affairs Healthcare System, Boston, MA 02130, USA
- Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
- Corresponding author.
| |
Collapse
|
24
|
Flesher SN, Collinger JL, Foldes ST, Weiss JM, Downey JE, Tyler-Kabara EC, Bensmaia SJ, Schwartz AB, Boninger ML, Gaunt RA. Intracortical microstimulation of human somatosensory cortex. Sci Transl Med 2016; 8:361ra141. [PMID: 27738096 DOI: 10.1126/scitranslmed.aaf8083] [Citation(s) in RCA: 432] [Impact Index Per Article: 48.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2016] [Accepted: 10/05/2016] [Indexed: 12/21/2022]
Abstract
Intracortical microstimulation of the somatosensory cortex offers the potential for creating a sensory neuroprosthesis to restore tactile sensation. Whereas animal studies have suggested that both cutaneous and proprioceptive percepts can be evoked using this approach, the perceptual quality of the stimuli cannot be measured in these experiments. We show that microstimulation within the hand area of the somatosensory cortex of a person with long-term spinal cord injury evokes tactile sensations perceived as originating from locations on the hand and that cortical stimulation sites are organized according to expected somatotopic principles. Many of these percepts exhibit naturalistic characteristics (including feelings of pressure), can be evoked at low stimulation amplitudes, and remain stable for months. Further, modulating the stimulus amplitude grades the perceptual intensity of the stimuli, suggesting that intracortical microstimulation could be used to convey information about the contact location and pressure necessary to perform dexterous hand movements associated with object manipulation.
Collapse
Affiliation(s)
- Sharlene N Flesher
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA
| | - Jennifer L Collinger
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Center for the Neural Basis of Cognition, Pittsburgh, PA 15213, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Department of Veterans Affairs Medical Center, Pittsburgh, PA 15206, USA
| | - Stephen T Foldes
- Center for the Neural Basis of Cognition, Pittsburgh, PA 15213, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Department of Veterans Affairs Medical Center, Pittsburgh, PA 15206, USA
| | - Jeffrey M Weiss
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213, USA
| | - John E Downey
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Center for the Neural Basis of Cognition, Pittsburgh, PA 15213, USA
| | - Elizabeth C Tyler-Kabara
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Department of Neurological Surgery, University of Pittsburgh, Pittsburgh, PA 15213, USA.,McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA
| | - Sliman J Bensmaia
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, IL 60637, USA
| | - Andrew B Schwartz
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Center for the Neural Basis of Cognition, Pittsburgh, PA 15213, USA.,McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA.,Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Systems Neuroscience Institute, University of Pittsburgh, Pittsburgh, PA 15213, USA
| | - Michael L Boninger
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213, USA.,Department of Veterans Affairs Medical Center, Pittsburgh, PA 15206, USA.,McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA
| | - Robert A Gaunt
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA. .,Center for the Neural Basis of Cognition, Pittsburgh, PA 15213, USA.,Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213, USA
| |
Collapse
|
25
|
Dadarlat MC, Sabes PN. Encoding and Decoding of Multi-Channel ICMS in Macaque Somatosensory Cortex. IEEE TRANSACTIONS ON HAPTICS 2016; 9:508-514. [PMID: 27740497 DOI: 10.1109/toh.2016.2616311] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Naturalistic control of brain-machine interfaces will require artificial proprioception, potentially delivered via intracortical microstimulation (ICMS). We have previously shown that multi-channel ICMS can guide a monkey reaching to unseen targets in a planar workspace. Here, we expand on that work, asking how ICMS is decoded into target angle and distance by analyzing the performance of a monkey when ICMS feedback was degraded. From the resulting pattern of errors, we found that the animal's estimate of target direction was consistent with a weighted circular-mean strategy-close to the optimal decoding strategy given the ICMS encoding. These results support our previous finding that animals can learn to use this artificial sensory feedback in an efficient and naturalistic manner.
Collapse
|
26
|
Roux S, Matonti F, Dupont F, Hoffart L, Takerkart S, Picaud S, Pham P, Chavane F. Probing the functional impact of sub-retinal prosthesis. eLife 2016; 5. [PMID: 27549126 PMCID: PMC4995098 DOI: 10.7554/elife.12687] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Accepted: 07/07/2016] [Indexed: 11/27/2022] Open
Abstract
Retinal prostheses are promising tools for recovering visual functions in blind patients but, unfortunately, with still poor gains in visual acuity. Improving their resolution is thus a key challenge that warrants understanding its origin through appropriate animal models. Here, we provide a systematic comparison between visual and prosthetic activations of the rat primary visual cortex (V1). We established a precise V1 mapping as a functional benchmark to demonstrate that sub-retinal implants activate V1 at the appropriate position, scalable to a wide range of visual luminance, but with an aspect-ratio and an extent much larger than expected. Such distorted activation profile can be accounted for by the existence of two sources of diffusion, passive diffusion and activation of ganglion cells’ axons en passant. Reverse-engineered electrical pulses based on impedance spectroscopy is the only solution we tested that decreases the extent and aspect-ratio, providing a promising solution for clinical applications. DOI:http://dx.doi.org/10.7554/eLife.12687.001 One of the most common causes of blindness is a disorder called retinitis pigmentosa. In a healthy eye, the surface at the back of the eye – called the retina – contains cells called photoreceptors that detect light and convert it into electrical signals for the brain to process. In people with retinitis pigmentosa, these photoreceptor cells die off gradually, which leads to loss of vision. The only treatment available for retinitis pigmentosa is to have an artificial retina implanted into the eye. The artificial retina consists of an array of tiny electrodes, which take over from the damaged photoreceptors and generate electrical signals. The person with the implant perceives these electrical signals as bright flashes called “phosphenes”. However, the phosphenes are too large and imprecise to provide the person with vision that is good enough for tasks such as walking unaided or reading. To find out why artificial retinas produce such poor resolution, Roux et al. compared how a rat’s brain responds to either natural visual stimuli or activation of implanted an array of micro-electrodes. Both the micro-electrodes and the natural stimuli activated the same areas of the brain. However, the micro-electrodes produced larger and more elongated patterns of activation. This is because the electrical currents generated by the micro-electrodes diffused throughout the retinal tissue and activated other neurons besides those intended. To overcome this problem, Roux et al. tested different ways of stimulating the micro-electrodes in order to identify those that induce the desired patterns of brain activity. This approach – known as reverse engineering – did indeed improve the performance of the micro-electrode array. The next step is to extend these findings, which were obtained in healthy rats, to non-human primates or animal models of retinitis pigmentosa to better understand the condition in humans. In addition, combining the current approach with other existing techniques should further improve the vision that can be achieved with artificial retinas. DOI:http://dx.doi.org/10.7554/eLife.12687.002
Collapse
Affiliation(s)
- Sébastien Roux
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France
| | - Frédéric Matonti
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France.,Ophthalmology Department, Aix Marseille Université, Hôpital Nord,Hôpital de la Timone, Marseille, France
| | - Florent Dupont
- CEA-LETI, Grenoble, France.,Université Grenoble Alpes, Grenoble, France
| | - Louis Hoffart
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France.,Ophthalmology Department, Aix Marseille Université, Hôpital Nord,Hôpital de la Timone, Marseille, France
| | - Sylvain Takerkart
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France
| | - Serge Picaud
- Inserm, UMRS-986, Institut de la vision, Paris, France
| | - Pascale Pham
- CEA-LETI, Grenoble, France.,Université Grenoble Alpes, Grenoble, France
| | - Frédéric Chavane
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France
| |
Collapse
|
27
|
Neuronal expression of c-Fos after epicortical and intracortical electric stimulation of the primary visual cortex. J Chem Neuroanat 2016; 77:121-128. [PMID: 27364963 DOI: 10.1016/j.jchemneu.2016.06.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Accepted: 06/25/2016] [Indexed: 11/20/2022]
Abstract
Electrical stimulation of the primary visual cortex (V1) is an experimental approach for visual prostheses. We here compared the response to intracortical and epicortical stimulation of the primary visual cortex by using c-Fos immunoreactivity as a marker for neuronal activation. The primary visual cortex of male Sprague Dawley rats was unilaterally stimulated for four hours using bipolar electrodes placed either intracortically in layer IV (n=26) or epicortically (n=20). Four different current intensities with a constant pulse width of 200μs and a constant frequency of 10Hz were used, for intracortical stimulation with an intensity of 0μA (sham-stimulation), 10μA, 20μA and 40μA, and for epicortical stimulation 0μA, 400μA, 600μA and 800μA. Subsequently all animals underwent c-Fos immunostaining and c-Fos expression was assessed in layer I-VI of the primary visual cortex within 200μm and 400μm distance to the stimulation site. C-Fos expression was higher after intracortical stimulation compared to epicortical stimulation, even though ten times lower current intensities were applied. Furthermore intracortical stimulation resulted in more focal neuronal activation than epicortical stimulation. C-Fos expression was highest after intracortical stimulation with 20μA compared to all other intensities. Epicortical stimulation showed a linear increase of c-Fos expression with the highest expression at 800μA. Sham stimulation showed similar expression of c-Fos in both hemispheres. The contralateral hemisphere was not affected by intracortical or epicortical stimulation of either intensities. In summary, intracortical stimulation resulted in more focal neuronal activation with less current than epicortical stimulation. This model may be used as a simple but reliable model to evaluate electrodes for microstimulation of the primary visual cortex before testing in more complex settings.
Collapse
|
28
|
Cicmil N, Krug K. Playing the electric light orchestra--how electrical stimulation of visual cortex elucidates the neural basis of perception. Philos Trans R Soc Lond B Biol Sci 2016; 370:20140206. [PMID: 26240421 PMCID: PMC4528818 DOI: 10.1098/rstb.2014.0206] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Vision research has the potential to reveal fundamental mechanisms underlying sensory experience. Causal experimental approaches, such as electrical microstimulation, provide a unique opportunity to test the direct contributions of visual cortical neurons to perception and behaviour. But in spite of their importance, causal methods constitute a minority of the experiments used to investigate the visual cortex to date. We reconsider the function and organization of visual cortex according to results obtained from stimulation techniques, with a special emphasis on electrical stimulation of small groups of cells in awake subjects who can report their visual experience. We compare findings from humans and monkeys, striate and extrastriate cortex, and superficial versus deep cortical layers, and identify a number of revealing gaps in the ‘causal map′ of visual cortex. Integrating results from different methods and species, we provide a critical overview of the ways in which causal approaches have been used to further our understanding of circuitry, plasticity and information integration in visual cortex. Electrical stimulation not only elucidates the contributions of different visual areas to perception, but also contributes to our understanding of neuronal mechanisms underlying memory, attention and decision-making.
Collapse
Affiliation(s)
- Nela Cicmil
- Department of Physiology, Anatomy and Genetics, University of Oxford, Parks Road, Oxford OX1 3PT, UK
| | - Kristine Krug
- Department of Physiology, Anatomy and Genetics, University of Oxford, Parks Road, Oxford OX1 3PT, UK
| |
Collapse
|
29
|
Christie BP, Ashmont KR, House PA, Greger B. Approaches to a cortical vision prosthesis: implications of electrode size and placement. J Neural Eng 2016; 13:025003. [PMID: 26905379 DOI: 10.1088/1741-2560/13/2/025003] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE In order to move forward with the development of a cortical vision prosthesis, the critical issues in the field must be identified. APPROACH To begin this process, we performed a brief review of several different cortical and retinal stimulation techniques that can be used to restore vision. MAIN RESULTS Intracortical microelectrodes and epicortical macroelectrodes have been evaluated as the basis of a vision prosthesis. We concluded that an important knowledge gap necessitates an experimental in vivo performance evaluation of microelectrodes placed on the surface of the visual cortex. A comparison of the level of vision restored by intracortical versus epicortical microstimulation is necessary. Because foveal representation in the primary visual cortex involves more cortical columns per degree of visual field than does peripheral vision, restoration of foveal vision may require a large number of closely spaced microelectrodes. Based on previous studies of epicortical macrostimulation, it is possible that stimulation via surface microelectrodes could produce a lower spatial resolution, making them better suited for restoring peripheral vision. SIGNIFICANCE The validation of epicortical microstimulation in addition to the comparison of epicortical and intracortical approaches for vision restoration will fill an important knowledge gap and may have important implications for surgical strategies and device longevity. It is possible that the best approach to vision restoration will utilize both epicortical and intracortical microstimulation approaches, applying them appropriately to different visual representations in the primary visual cortex.
Collapse
Affiliation(s)
- Breanne P Christie
- School of Biological and Health Systems Engineering, Arizona State University, Tempe AZ, USA
| | | | | | | |
Collapse
|
30
|
Chernov MM, Chen G, Torre-Healy LA, Friedman RM, Roe AW. Microelectrode array stimulation combined with intrinsic optical imaging: A novel tool for functional brain mapping. J Neurosci Methods 2016; 263:7-14. [PMID: 26820903 DOI: 10.1016/j.jneumeth.2016.01.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2015] [Revised: 12/24/2015] [Accepted: 01/16/2016] [Indexed: 02/03/2023]
Abstract
BACKGROUND Functional brain mapping via cortical microstimulation is a widely used clinical and experimental tool. However, data are traditionally collected point by point, making the technique very time consuming. Moreover, even in skilled hands, consistent penetration depths are difficult to achieve. Finally, the effects of microstimulation are assessed behaviorally, with no attempt to capture the activity of the local cortical circuits being stimulated. NEW METHOD We propose a novel method for functional brain mapping, which combines the use of a microelectrode array with intrinsic optical imaging. The precise spacing of electrodes allows for fast, accurate mapping of the area of interest in a regular grid. At the same time, the optical window allows for visualization of local neural connections when stimulation is combined with intrinsic optical imaging. RESULTS We demonstrate the efficacy of our technique using the primate motor cortex as a sample application, using a combination of microstimulation, imaging and electrophysiological recordings during wakefulness and under anesthesia. Comparison with current method: We find the data collected with our method is consistent with previous data published by others. We believe that our approach enables data to be collected faster and in a more consistent fashion and makes possible a number of studies that would be difficult to carry out with the traditional approach. CONCLUSIONS Our technique allows for simultaneous modulation and imaging of cortical sensorimotor networks in wakeful subjects over multiple sessions which is highly desirable for both the study of cortical organization and the design of brain machine interfaces.
Collapse
Affiliation(s)
- Mykyta M Chernov
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States.
| | - Gang Chen
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States
| | - Luke A Torre-Healy
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States
| | - Robert M Friedman
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States
| | - Anna W Roe
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States
| |
Collapse
|
31
|
Callier T, Schluter EW, Tabot GA, Miller LE, Tenore FV, Bensmaia SJ. Long-term stability of sensitivity to intracortical microstimulation of somatosensory cortex. J Neural Eng 2015; 12:056010. [DOI: 10.1088/1741-2560/12/5/056010] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
32
|
Stephani C, Koubeissi M. Differences of Intracranial Electrical Stimulation Thresholds in the Human Brain. Brain Stimul 2015; 8:724-9. [DOI: 10.1016/j.brs.2015.02.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2015] [Accepted: 02/27/2015] [Indexed: 12/01/2022] Open
|
33
|
Tehovnik E, Slocum W. Two-photon imaging and the activation of cortical neurons. Neuroscience 2013; 245:12-25. [DOI: 10.1016/j.neuroscience.2013.04.022] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2012] [Revised: 02/22/2013] [Accepted: 04/10/2013] [Indexed: 10/26/2022]
|
34
|
Tehovnik EJ, Slocum WM. Electrical induction of vision. Neurosci Biobehav Rev 2013; 37:803-18. [PMID: 23535445 DOI: 10.1016/j.neubiorev.2013.03.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2012] [Revised: 01/28/2013] [Accepted: 03/17/2013] [Indexed: 11/26/2022]
Abstract
We assess what monkeys see during electrical stimulation of primary visual cortex (area V1) and relate the findings to visual percepts evoked electrically from human V1. Discussed are: (1) the electrical, cytoarchitectonic, and visuo-behavioural factors that affect the ability of monkeys to detect currents in V1; (2) the methods used to ascertain what monkeys see when electrical stimulation is delivered to V1; (3) a corticofugal mechanism for the induction of visual percepts; and (4) the quantity of information transferred to V1 by electrical stimulation. Experiments are proposed that should advance our understanding of how electrical stimulation affects macaque and human V1. This work contributes to the development of a cortical visual prosthesis for the blind. We dedicate this work to the late Robert W. Doty.
Collapse
|
35
|
Davis TS, Parker RA, House PA, Bagley E, Wendelken S, Normann RA, Greger B. Spatial and temporal characteristics of V1 microstimulation during chronic implantation of a microelectrode array in a behaving macaque. J Neural Eng 2012; 9:065003. [PMID: 23186948 PMCID: PMC3521049 DOI: 10.1088/1741-2560/9/6/065003] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE It has been hypothesized that a vision prosthesis capable of evoking useful visual percepts can be based upon electrically stimulating the primary visual cortex (V1) of a blind human subject via penetrating microelectrode arrays. As a continuation of earlier work, we examined several spatial and temporal characteristics of V1 microstimulation. APPROACH An array of 100 penetrating microelectrodes was chronically implanted in V1 of a behaving macaque monkey. Microstimulation thresholds were measured using a two-alternative forced choice detection task. Relative locations of electrically-evoked percepts were measured using a memory saccade-to-target task. MAIN RESULTS The principal finding was that two years after implantation we were able to evoke behavioural responses to electric stimulation across the spatial extent of the array using groups of contiguous electrodes. Consistent responses to stimulation were evoked at an average threshold current per electrode of 204 ± 49 µA (mean ± std) for groups of four electrodes and 91 ± 25 µA for groups of nine electrodes. Saccades to electrically-evoked percepts using groups of nine electrodes showed that the animal could discriminate spatially distinct percepts with groups having an average separation of 1.6 ± 0.3 mm (mean ± std) in cortex and 1.0° ± 0.2° in visual space. Significance. These results demonstrate chronic perceptual functionality and provide evidence for the feasibility of a cortically-based vision prosthesis for the blind using penetrating microelectrodes.
Collapse
Affiliation(s)
- T S Davis
- Department of Bioengineering, University of Utah, UT, USA
| | - R A Parker
- Interdepartmental Program in Neuroscience, University of Utah, UT, USA
| | - P A House
- Department of Neurosurgery, University of Utah, UT, USA
| | - E Bagley
- Department of Bioengineering, University of Utah, UT, USA
| | - S Wendelken
- Department of Bioengineering, University of Utah, UT, USA
| | - R A Normann
- Department of Bioengineering, University of Utah, UT, USA
- Department of Ophthalmology and Visual Sciences, University of Utah, UT, USA
| | - B Greger
- Department of Bioengineering, University of Utah, UT, USA
- Department of Ophthalmology and Visual Sciences, University of Utah, UT, USA
| |
Collapse
|
36
|
Koivuniemi AS, Regele OB, Brenner JH, Otto KJ. Rat behavioral model for high-throughput parametric studies of intracortical microstimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:7541-4. [PMID: 22256083 DOI: 10.1109/iembs.2011.6091859] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In the development of sensory prosthetic devices based on intracortical microstimulation (ICMS) an important objective is to optimize the stimulus waveform. However, because of the large design space such optimization is an imposing challenge. This study highlights the ability of individual rats, trained using a conditioned avoidance paradigm and performing an adaptive task, to generate highly consistent and significant data. Three experiments on the effects of phase delay, stimulus pulse rate, and waveform asymmetry were completed and revealed detailed and significant results. These results, consisting of 244 individual thresholds, were generated by one rat in 19 days.
Collapse
Affiliation(s)
- Andrew S Koivuniemi
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA.
| | | | | | | |
Collapse
|
37
|
New methods devised specify the size and color of the spots monkeys see when striate cortex (area V1) is electrically stimulated. Proc Natl Acad Sci U S A 2011; 108:17809-14. [PMID: 21987821 DOI: 10.1073/pnas.1108337108] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Creating a prosthetic device for the blind is a central future task. Our research examines the feasibility of producing a prosthetic device based on electrical stimulation of primary visual cortex (area V1), an area that remains intact for many years after loss of vision attributable to damage to the eyes. As an initial step in this effort, we believe that the research should be carried out in animals, as it has been in the creation of the highly successful cochlear implant. We chose the rhesus monkey, whose visual system is similar to that of man. We trained monkeys on two tasks to assess the size, contrast, and color of the percepts created when single sites in area V1 are stimulated through microelectrodes. Here, we report that electrical stimulation within the central 5° of the visual field representation creates a small spot that is between 9 and 26 min of arc in diameter and has a contrast ranging between 2.6% and 10%. The dot generated by the stimulation in the majority of cases was darker than the background viewed by the animal and was composed of a variety of low-contrast colors. These findings can be used as inputs to models of electrical stimulation in area V1. On the basis of these findings, we derive what kinds of images would be expected when implanted arrays of electrodes are stimulated through a camera attached to the head whose images are converted into electrical stimulation using appropriate algorithms.
Collapse
|
38
|
Koivuniemi AS, Otto KJ. Asymmetric versus symmetric pulses for cortical microstimulation. IEEE Trans Neural Syst Rehabil Eng 2011; 19:468-76. [PMID: 21968793 DOI: 10.1109/tnsre.2011.2166563] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Intracortical microstimulation (ICMS), which has shown promise in the visual, auditory and somatosensory systems as a platform for sensory prostheses, typically relies on charged balanced, symmetric, biphasic stimulation. However, neural stimulation models as well as experiments conducted in cochlear implant users have suggested that charge balanced asymmetric pulses could generate lower detection thresholds for stimulation in terms of charge per phase. For this study, rats were chronically implanted with microelectrode arrays unilaterally in their right auditory cortex and then trained to detect ICMS delivered through a single electrode site in order to determine their behavioral threshold. This model was used in two experiments. The first experiment addressed the effect of lead phase direction, asymmetry, and phase duration on detection threshold. The second experiment fixed the cathode phase duration at 123 μs and varied only the phase asymmetry and lead phase direction. Taken together, the results of these experiments suggest that, for ICMS, the primary determinant of threshold level is cathode phase duration, and that asymmetry provides no significant advantage when compared to symmetric, cathode leading pulses. However, symmetric anode leading pulses of less than or equal to 205 μs per phase consistently showed higher thresholds when compared to all other pulses of equal cathode phase duration.
Collapse
Affiliation(s)
- Andrew S Koivuniemi
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA.
| | | |
Collapse
|
39
|
Yu XJ, Meng XK, Xu XX, He J. Individual auditory thalamic reticular neurons have large and cross-modal sources of cortical and thalamic inputs. Neuroscience 2011; 193:122-31. [DOI: 10.1016/j.neuroscience.2011.07.040] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2011] [Revised: 07/19/2011] [Accepted: 07/20/2011] [Indexed: 10/17/2022]
|
40
|
Koivuniemi A, Wilks SJ, Woolley AJ, Otto KJ. Multimodal, longitudinal assessment of intracortical microstimulation. PROGRESS IN BRAIN RESEARCH 2011; 194:131-44. [PMID: 21867800 DOI: 10.1016/b978-0-444-53815-4.00011-x] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The fundamental obstacle to neuroprostheses based on penetrating microstimulation is the tissue's response to the device insertion and to the application of the electrical stimulation. Our long-term goal is to develop multichannel microstimulation of central nervous tissue for clinical therapy. The overall objective of this research is to identify the optimal parameters for a chronically implanted microstimulation device. In particular, the work presented here focuses on the effects of repeated stimulation and the reactive tissue response on the efficacy of stimulation-driven behavior. To this end, psychophysical experiments were performed using multichannel cortical implants in the auditory cortex of rats. Further, we investigated the effect of the device-tissue interfacial quality on the psychophysical threshold. Here, we report the effects of cortical depth, days postimplant on the psychophysical threshold of auditory cortical microstimulation, along with correlated impedance spectral changes and post vivo histology. We expect that these data will further enable neuroprosthetic development.
Collapse
Affiliation(s)
- Andrew Koivuniemi
- The Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | | | | | | |
Collapse
|
41
|
Tehovnik EJ, Slocum WM. Background luminance affects the detection of microampere currents delivered to macaque striate cortex. Eur J Neurosci 2009; 30:263-71. [PMID: 19558620 DOI: 10.1111/j.1460-9568.2009.06810.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Monkeys detect electrical microstimulation delivered to the striate cortex (area V1). We examined whether the ability of monkeys to detect such stimulation is affected by background luminance. While remaining fixated on a spot of light centered on a monitor, a monkey was required to detect a 100 ms train of electrical stimulation delivered to a site within area V1 situated from 1 to 1.5 mm below the cortical surface. A monkey signaled the delivery of stimulation by depressing a lever after which it was rewarded with a drop of apple juice. Control trials were interleaved during which time no stimulation was delivered and the monkey was rewarded for not depressing the lever. Biphasic pulses were delivered at 200 Hz and the current ranged from 2 to 30 microA using 0.2 ms anode-first biphasic pulses. The background luminance level of the monitor could be varied from 0.005 to 148 cd/m(2). It was found that, for monitor luminance levels below 10 cd/m(2), the current threshold to evoke a detection response increased. We discuss the significance of this result with regard to phosphenes elicited from human V1 and in relation to visual perception.
Collapse
Affiliation(s)
- Edward J Tehovnik
- Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
| | | |
Collapse
|
42
|
Tehovnik EJ, Slocum WM, Smirnakis SM, Tolias AS. Microstimulation of visual cortex to restore vision. PROGRESS IN BRAIN RESEARCH 2009; 175:347-75. [PMID: 19660667 DOI: 10.1016/s0079-6123(09)17524-6] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
This review argues that one reason why a functional visuo-cortical prosthetic device has not been developed to restore even minimal vision to blind individuals is because there is no animal model to guide the design and development of such a device. Over the past 8 years we have been conducting electrical microstimulation experiments on alert behaving monkeys with the aim of better understanding how electrical stimulation of the striate cortex (area V1) affects oculo- and skeleto-motor behaviors. Based on this work and upon review of the literature, we arrive at several conclusions: (1) As with the development of the cochlear implant, the development of a visuo-cortical prosthesis can be accelerated by using animals to test the perceptual effects of microstimulating V1 in intact and blind monkeys. (2) Although a saccade-based paradigm is very convenient for studying the effectiveness of delivering stimulation to V1 to elicit saccadic eye movements, it is less ideal for probing the volitional state of monkeys, as they perceive electrically induced phosphenes. (3) Electrical stimulation of V1 can delay visually guided saccades generated to a punctate target positioned in the receptive field of the stimulated neurons. We call the region of visual space affected by the stimulation a delay field. The study of delay fields has proven to be an efficient way to study the size and shape of phosphenes generated by stimulation of macaque V1. (4) An alternative approach to ascertain what monkeys see during electrical stimulation of V1 is to have them signal the detection of current with a lever press. Monkeys can readily detect currents of 1-2 microA delivered to V1. In order to evoke featured phosphenes currents of under 5 microA will be necessary. (5) Partially lesioning the retinae of monkeys is superior to completely lesioning the retinae when determining how blindness affects phosphene induction. We finish by proposing a future experimental paradigm designed to determine what monkeys see when stimulation is delivered to V1, by assessing how electrical fields generated through multiple electrodes interact for the production of phosphenes, and by depicting a V1 circuit that could mediate electrically induced phosphenes.
Collapse
Affiliation(s)
- Edward J Tehovnik
- Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, USA.
| | | | | | | |
Collapse
|