1
|
Luo H, Zeng L, Yin X, Pan Y, Yang J, Liu M, Qin X, Feng Z, Chen W, Zheng H. An isothermal CRISPR-based diagnostic assay for Neisseria gonorrhoeae and Chlamydia trachomatis detection. Microbiol Spectr 2023; 11:e0046423. [PMID: 37882532 PMCID: PMC10715037 DOI: 10.1128/spectrum.00464-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 09/27/2023] [Indexed: 10/27/2023] Open
Abstract
IMPORTANCE A method for Neisseria gonorrhoeae (NG)/Chlamydia trachomatis (CT) detection is developed using multiplex-recombinase polymerase amplification and Cas12a/Cas13a. This method can detect NG and CT simultaneously with high sensitivity and specificity. This method has great potential to be further developed into larger-scale screening and point-of-care testing (POCT).
Collapse
Affiliation(s)
- Hao Luo
- Dermatology Hosptial, Southern Medical University, Guangzhou, China
- Guangzhou Key Laboratory for Sexually Transmitted Diseases Control, Guangzhou, China
| | - Lihong Zeng
- Dermatology Hosptial, Southern Medical University, Guangzhou, China
- Guangzhou Key Laboratory for Sexually Transmitted Diseases Control, Guangzhou, China
| | - Xiaona Yin
- Dermatology Hosptial, Southern Medical University, Guangzhou, China
- Guangzhou Key Laboratory for Sexually Transmitted Diseases Control, Guangzhou, China
| | - Yuying Pan
- Dermatology Hosptial, Southern Medical University, Guangzhou, China
- Guangzhou Key Laboratory for Sexually Transmitted Diseases Control, Guangzhou, China
| | - Jianjiang Yang
- Dermatology Hosptial, Southern Medical University, Guangzhou, China
- Guangzhou Key Laboratory for Sexually Transmitted Diseases Control, Guangzhou, China
| | - Mingjing Liu
- Medical College, China Three Gorges University, Yichang, China
| | - Xiaolin Qin
- Dermatology Hosptial, Southern Medical University, Guangzhou, China
- Guangzhou Key Laboratory for Sexually Transmitted Diseases Control, Guangzhou, China
| | - Zhanqin Feng
- Dermatology Hosptial, Southern Medical University, Guangzhou, China
- Guangzhou Key Laboratory for Sexually Transmitted Diseases Control, Guangzhou, China
| | - Wentao Chen
- Dermatology Hosptial, Southern Medical University, Guangzhou, China
- Guangzhou Key Laboratory for Sexually Transmitted Diseases Control, Guangzhou, China
| | - Heping Zheng
- Dermatology Hosptial, Southern Medical University, Guangzhou, China
- Guangzhou Key Laboratory for Sexually Transmitted Diseases Control, Guangzhou, China
| |
Collapse
|
2
|
Mollasalehi H, Esmaili F, Minai-Tehrani D. Development and evaluation of a colorimetric LAMP-based biosensor for rapid detection of a nosocomial infection agent, Citrobacter freundii. Sci Rep 2023; 13:21896. [PMID: 38081996 PMCID: PMC10713557 DOI: 10.1038/s41598-023-49329-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 12/07/2023] [Indexed: 12/18/2023] Open
Abstract
Simple and fast diagnosis of Citrobacter freundii which is an important cause of nosocomial infection in human is crucial to achieve early treatment. We have developed and evaluated an optical LAMP-based biosensor for the visual detection of C. freundii for the first time. The efficiency of the assay was investigated and compared to PCR method. The selectivity and specificity of the biosensor were analyzed using Morganella morganii, Enterobacter aerogenes, Pseudomonas aeruginosa, Yersinia enterocolitica, Shigella sonnei, Serratia marcescens, Burkholderia cepacia and Klebsiella pneumoniae and a mixed-culture medium. Endpoint analysis using hydroxy naphthol blue was applied, and the color change to sky blue and no color change from violet indicated positive and negative results, respectively. The absorption at 650 nm was measured 0.39 for the positive sample, while the mean absorption of the test samples, including water, was 0.23. The specificity of the method was equal to that of PCR. However, the sensitivity was determined as 12.24 fg/µL of the genomic content of C. freundii, higher than PCR assay. The developed LAMP-based method provided a rapid and accurate technique for molecular diagnostics of C. freundii, making it a suitable technique for point-of-care diagnostics in cases of urgent situations.
Collapse
Affiliation(s)
- Hamidreza Mollasalehi
- Department of Microbiology and Microbial Biotechnology, Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Velenjak, Tehran, 1983969411, Iran.
| | - Faezeh Esmaili
- Department of Microbiology and Microbial Biotechnology, Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Velenjak, Tehran, 1983969411, Iran
| | - Dariush Minai-Tehrani
- Department of Microbiology and Microbial Biotechnology, Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Velenjak, Tehran, 1983969411, Iran
| |
Collapse
|
3
|
Tavakoli-Koopaei R, Javadi-Zarnaghi F, Aboutalebian S, Mirhendi H. Malachite Green-Based Detection of SARS-CoV-2 by One-Step Reverse Transcription Loop-Mediated Isothermal Amplification. IRANIAN JOURNAL OF SCIENCE 2023. [PMCID: PMC9898859 DOI: 10.1007/s40995-022-01392-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The pandemic of severe acute respiratory syndrome 2 (SARS-CoV-2) revealed the necessity of diagnosis of the infected people to prevent the prevalence infection cycle. Many commercial pathogen diagnosis methods are based on the detection of genomic materials. Isothermal amplification methods such as loop-mediated-isothermal amplification (LAMP) are the method of choice in these cases. Reverse transcription steps are efficiently coupled to LAMP for the detection of pathogens with genomic RNAs such as SARS-CoV-2. Many detection systems for LAMP include fluorescent readout systems. Although such systems result in desirable limits of detection, the need for special instrumentation is the main dispute of such systems to become real point of care assays. In contrast, colorimetric detection methods would reduce costs and improve the applicability of the system. In this study one-step reverse transcription-LAMP reaction was established that enables visual detection of the SARS-CoV-2 genome. Nasopharyngeal RNA samples were first validated by reverse transcription quantitative polymerase chain reaction and then subjected to RT-LAMP. To lower the cost associated with the readout system equipment, malachite green (MG) was used. The color change of MG to blue allowed visual detection of the virus. Firstly, experiments were set up as two-step RT-LAMP reaction to identify the best primer sets. In addition, MG concentration was optimized with the significant colorimetric signal for the positive samples. Next, a one-step colorimetric method was developed for the detection of SARS-CoV-2 based on MG color shift in 2 h.
Collapse
Affiliation(s)
- Reyhaneh Tavakoli-Koopaei
- grid.411750.60000 0001 0454 365XDepartment of Cell and Molecular Biology & Microbiology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, Iran
| | - Fatemeh Javadi-Zarnaghi
- grid.411750.60000 0001 0454 365XDepartment of Cell and Molecular Biology & Microbiology, Faculty of Biological Science and Technology, University of Isfahan, Isfahan, Iran
| | - Shima Aboutalebian
- grid.411036.10000 0001 1498 685XDepartment of Medical Parasitology and Mycology, School of Medicine, Research Core Facilities Laboratory, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Hossein Mirhendi
- grid.411036.10000 0001 1498 685XDepartment of Medical Parasitology and Mycology, School of Medicine, Research Core Facilities Laboratory, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
4
|
Chen X, Zhou Q, Yuan W, Shi Y, Dong S, Luo X. Visual and rapid identification of Chlamydia trachomatis and Neisseria gonorrhoeae using multiplex loop-mediated isothermal amplification and a gold nanoparticle-based lateral flow biosensor. Front Cell Infect Microbiol 2023; 13:1067554. [PMID: 36926514 PMCID: PMC10011439 DOI: 10.3389/fcimb.2023.1067554] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 02/15/2023] [Indexed: 03/08/2023] Open
Abstract
Sexually transmitted chlamydia and gonorrhea infections caused by the bacteria Chlamydia trachomatis and Neisseria gonorrhoeae remain a major public health concern worldwide, particularly in less developed nations. It is crucial to use a point of care (POC) diagnostic method that is quick, specific, sensitive, and user-friendly to treat and control these infections effectively. Here, a novel molecular diagnostic assay, combining multiplex loop-mediated isothermal amplification (mLAMP) with a visual gold nanoparticles-based lateral flow biosensor (AuNPs-LFB) was devised and used for highly specific, sensitive, rapid, visual, and easy identification of C. trachomatis and N. gonorrhoeae. Two unique independent primer pairs were successful designed against the ompA and orf1 genes of C. trachomatis and N. gonorrhoeae, respectively. The optimal mLAMP-AuNPs-LFB reaction conditions were determined to be 67°C for 35 min. The detection procedure, involving crude genomic DNA extraction (~5 min), LAMP amplification (35 min), and visual results interpretation (<2 min), can be completed within 45 min. Our assay has a detection limit of 50 copies per test, and we did not observe any cross-reactivity with any other bacteria in our testing. Hence, our mLAMP-AuNPs-LFB assay can potentially be used for POC testing to detect C. trachomatis and N. gonorrhoeae in clinical settings, particularly in underdeveloped regions.
Collapse
Affiliation(s)
- Xu Chen
- The Second Clinical College, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, China
- Clinical Medical Laboratory of the Second Affiliated Hospital, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, China
- *Correspondence: Xinhua Luo, ; Shilei Dong, ; Xu Chen,
| | - Qingxue Zhou
- Clinical Laboratory, Hangzhou Women’s Hospital, Hangzhou, Zhejiang, China
| | - Wei Yuan
- Department of Quality Control, Guizhou Provincial Center for Clinical Laboratory, Guiyang, Guizhou, China
| | - Yuanfang Shi
- The Second Clinical College, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, China
| | - Shilei Dong
- Department of Clinical Laboratory, Zhejiang Hospital, Hangzhou, Zhejiang, China
- *Correspondence: Xinhua Luo, ; Shilei Dong, ; Xu Chen,
| | - Xinhua Luo
- Department of Infectious Disease, Guizhou Provincial People’s Hospital, Guiyang, Guizhou, China
- *Correspondence: Xinhua Luo, ; Shilei Dong, ; Xu Chen,
| |
Collapse
|
5
|
Rapid visual Candidatus Liberibacter asiaticus detection (citrus greening disease) using simple alkaline heat DNA lysis followed by loop-mediated isothermal amplification coupled hydroxynaphthol blue (AL-LAMP-HNB) for potential local use. PLoS One 2022; 17:e0276740. [PMID: 36282857 PMCID: PMC9595546 DOI: 10.1371/journal.pone.0276740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Accepted: 10/12/2022] [Indexed: 11/05/2022] Open
Abstract
An outbreak of citrus greening or Huanglongbing disease bacteria occurs in many areas. We sampled and identified an ongoing ~year 2020 orange tree endemic in northern Thailand as Candidatus Liberibacter asiaticus. We thereby developed a plant greening disease (C. Liberibacter asiaticus) detection assay using simple alkaline heat DNA lysis and loop-mediated isothermal amplification coupled hydroxynaphthol blue (AL-LAMP-HNB), and evaluated the developed assay for its feasibility as point-of-care detection on 65 plant leaf samples with 100–1×104 copies of C. Liberibacter asiaticus or mocked injection compared with commercial DNA lysis kit and PCR-GE. Our assay is sensitive to 5–8.9 copies of omp (equaling 0.0056–0.01 fg) compatible with PCR-GE limit of detection. This ultra sensitive limit of detection could allow the disease detection before clinical apparent state of disease when C. Liberibacter asiaticus infection number is few, i.e. fewer than 100 copies of C. Liberibacter asiaticus. The assay is also specific with 6 degenerate primers targeting every strain of C. Liberibacter asiaticus omp from GenBank database, rapid (40 min total assay time), inexpensive (~2–3 USD/reaction), does not require sophisticated instrumentation, and has comparable assay accuracy (93.85–100% accuracy, 100% specificity, and 89.74–100% sensitivity) to bacterial DNA extraction by a commercial kit followed by PCR and gel electrophoresis (92.31% accuracy, 100% specificity, and 87.18% sensitivity) based on the real sample tests. Hence, the technique could be used in local or laboratory resource-restricted settings. The test result could be read by naked eyes through the color change from violet (negative) to sky blue (positive) for a C. Liberibacter asiaticus-infected specimen. Furthermore, this assay uses safe chemical reagents and, thus, is safe for the users.
Collapse
|
6
|
Park JW. Principles and Applications of Loop-Mediated Isothermal Amplification to Point-of-Care Tests. BIOSENSORS 2022; 12:bios12100857. [PMID: 36290994 PMCID: PMC9599884 DOI: 10.3390/bios12100857] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 09/30/2022] [Accepted: 10/08/2022] [Indexed: 05/03/2023]
Abstract
For the identification of nucleic acids, which are important biomarkers of pathogen-mediated diseases and viruses, the gold standard for NA-based diagnostic applications is polymerase chain reaction (PCR). However, the requirements of PCR limit its application as a rapid point-of-care diagnostic technique. To address the challenges associated with regular PCR, many isothermal amplification methods have been developed to accurately detect NAs. Isothermal amplification methods enable NA amplification without changes in temperature with simple devices, as well as faster amplification times compared with regular PCR. Of the isothermal amplifications, loop-mediated isothermal amplification (LAMP) is the most studied because it amplifies NAs rapidly and specifically. This review describes the principles of LAMP, the methods used to monitor the process of LAMP, and examples of biosensors that detect the amplicons of LAMP. In addition, current trends in the application of LAMP to smartphones and self-diagnosis systems for point-of-care tests are also discussed.
Collapse
Affiliation(s)
- Jee-Woong Park
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation (K-MEDI Hub), Daegu 41061, Korea
| |
Collapse
|
7
|
Chen X, Zhou Q, Tan Y, Wang R, Wu X, Liu J, Liu R, Wang S, Dong S. Nanoparticle-Based Lateral Flow Biosensor Integrated With Loop-Mediated Isothermal Amplification for Rapid and Visual Identification of Chlamydia trachomatis for Point-of-Care Use. Front Microbiol 2022; 13:914620. [PMID: 35903464 PMCID: PMC9318599 DOI: 10.3389/fmicb.2022.914620] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 06/09/2022] [Indexed: 11/13/2022] Open
Abstract
Chlamydial infection, caused by Chlamydia trachomatis, is the most common bacterial sexually transmitted infection and remains a major public health problem worldwide, particularly in underdeveloped regions. Developing a rapid and sensitive point-of-care (POC) testing for accurate screening of C. trachomatis infection is critical for earlier treatment to prevent transmission. In this study, a novel diagnostic assay, loop-mediated isothermal amplification integrated with gold nanoparticle-based lateral flow biosensor (LAMP-LFB), was devised and applied for diagnosis of C. trachomatis in clinical samples. A set of LAMP primers based on the ompA gene from 14 C. trachomatis serological variants (serovar A-K, L1, L2, L3) was successfully designed and used for the development of C. trachomatis-LAMP-LFB assay. The optimal reaction system can be performed at a constant temperature of 67°C for 35 min. The total assay process, including genomic DNA extraction (~15 min), LAMP reaction (35 min), and LFB readout (~2 min), could be finished within 60 min. The C. trachomatis-LAMP-LFB could detect down to 50 copies/ml, and the specificity was 100%, no cross-reactions with other pathogens were observed. Hence, our C. trachomatis-LAMP-LFB was a rapid, reliable, sensitive, cost-effective, and easy-to-operate assay, which could offer an attractive POC testing tool for chlamydial infection screening, especially in resource starvation settings.
Collapse
|
8
|
Geisler WM, Hocking JS, Darville T, Batteiger BE, Brunham RC. Diagnosis and Management of Uncomplicated Chlamydia trachomatis Infections in Adolescents and Adults: Summary of Evidence Reviewed for the 2021 Centers for Disease Control and Prevention Sexually Transmitted Infections Treatment Guidelines. Clin Infect Dis 2022; 74:S112-S126. [PMID: 35416965 PMCID: PMC9006972 DOI: 10.1093/cid/ciac126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
To prepare for the development of the 2021 Centers for Disease Control and Prevention (CDC) sexually transmitted infections treatment guidelines, the CDC convened a committee of expert consultants in June 2019 to discuss recent abstracts and published literature on the epidemiology, diagnosis, and management of sexually transmitted infections.This paper summarizes the key questions, evidence, and recommendations for the diagnosis and management of uncomplicated Chlamydia trachomatis (CT) infections in adolescents and adults that were reviewed and discussed for consideration in developing the guidelines. The evidence reviewed mostly focused on efficacy of doxycycline and azithromycin for urogenital, rectal, and oropharyngeal CT infection, CT risk factors in women, performance of CT nucleic acid amplification tests on self-collected meatal specimens in men, and performance of newer CT point-of-care tests.
Collapse
Affiliation(s)
- William M Geisler
- Division of Infectious Diseases, Department of Medicine and Department of Epidemiology, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Jane S Hocking
- Centre for Epidemiology and Biostatistics, Melbourne School of Population and Global Health, University of Melbourne, Melbourne, Victoria, Australia
| | - Toni Darville
- Department of Pediatrics and Department of Microbiology and Immunology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Byron E Batteiger
- Department of Medicine and Department of Microbiology and Immunology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Robert C Brunham
- Vaccine Research Laboratory, University of British Columbia Centre for Disease Control, Vancouver, Canada
| |
Collapse
|
9
|
Hsieh K, Melendez JH, Gaydos CA, Wang TH. Bridging the gap between development of point-of-care nucleic acid testing and patient care for sexually transmitted infections. LAB ON A CHIP 2022; 22:476-511. [PMID: 35048928 PMCID: PMC9035340 DOI: 10.1039/d1lc00665g] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The incidence rates of sexually transmitted infections (STIs), including the four major curable STIs - chlamydia, gonorrhea, trichomoniasis and, syphilis - continue to increase globally, causing medical cost burden and morbidity especially in low and middle-income countries (LMIC). There have seen significant advances in diagnostic testing, but commercial antigen-based point-of-care tests (POCTs) are often insufficiently sensitive and specific, while near-point-of-care (POC) instruments that can perform sensitive and specific nucleic acid amplification tests (NAATs) are technically complex and expensive, especially for LMIC. Thus, there remains a critical need for NAAT-based STI POCTs that can improve diagnosis and curb the ongoing epidemic. Unfortunately, the development of such POCTs has been challenging due to the gap between researchers developing new technologies and healthcare providers using these technologies. This review aims to bridge this gap. We first present a short introduction of the four major STIs, followed by a discussion on the current landscape of commercial near-POC instruments for the detection of these STIs. We present relevant research toward addressing the gaps in developing NAAT-based STI POCT technologies and supplement this discussion with technologies for HIV and other infectious diseases, which may be adapted for STIs. Additionally, as case studies, we highlight the developmental trajectory of two different POCT technologies, including one approved by the United States Food and Drug Administration (FDA). Finally, we offer our perspectives on future development of NAAT-based STI POCT technologies.
Collapse
Affiliation(s)
- Kuangwen Hsieh
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Johan H Melendez
- Division of Infectious Diseases, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Charlotte A Gaydos
- Division of Infectious Diseases, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Tza-Huei Wang
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD 21218, USA
| |
Collapse
|
10
|
Nolasco O, Montoya J, Rosales Rosas AL, Barrientos S, Rosanas-Urgell A, Gamboa D. Multicopy targets for Plasmodium vivax and Plasmodium falciparum detection by colorimetric LAMP. Malar J 2021; 20:225. [PMID: 34011373 PMCID: PMC8135177 DOI: 10.1186/s12936-021-03753-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 05/07/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Loop-mediated isothermal amplification (LAMP) for malaria diagnosis at the point of care (POC) depends on the detection capacity of synthesized nucleic acids and the specificity of the amplification target. To improve malaria diagnosis, new colorimetric LAMP tests were developed using multicopy targets for Plasmodium vivax and Plasmodium falciparum detection. METHODS The cytochrome oxidase I (COX1) mitochondrial gene and the non-coding sequence Pvr47 for P. vivax, and the sub-telomeric sequence of erythrocyte membrane protein 1 (EMP1) and the non-coding sequence Pfr364 for P. falciparum were targeted to design new LAMP primers. The limit of detection (LOD) of each colorimetric LAMP was established and assessed with DNA extracted by mini spin column kit and the Boil & Spin method from 28 microscopy infections, 101 malaria submicroscopic infections detected by real-time PCR only, and 183 negatives infections by both microscopy and PCR. RESULTS The LODs for the colorimetric LAMPs were estimated between 2.4 to 3.7 parasites/µL of whole blood. For P. vivax detection, the colorimetric LAMP using the COX1 target showed a better performance than the Pvr47 target, whereas the Pfr364 target was the most specific for P. falciparum detection. All microscopic infections of P. vivax were detected by PvCOX1-LAMP using the mini spin column kit DNA extraction method and 81% (17/21) were detected using Boil & Spin sample preparation. Moreover, all microscopic infections of P. falciparum were detected by Pfr364-LAMP using both sample preparation methods. In total, PvCOX1-LAMP and Pfr364-LAMP detected 80.2% (81 samples) of the submicroscopic infections using the DNA extraction method by mini spin column kit, while 36.6% (37 samples) were detected using the Boil & Spin sample preparation method. CONCLUSION The colorimetric LAMPs with multicopy targets using the COX1 target for P. vivax and the Pfr364 for P. falciparum have a high potential to improve POC malaria diagnosis detecting a greater number of submicroscopic Plasmodium infections.
Collapse
Affiliation(s)
- Oscar Nolasco
- Instituto de Medicina Tropical "Alexander von Humboldt" Universidad Peruana Cayetano Heredia, Lima, Peru.
- Laboratorios de Investigación Y Desarrollo, Facultad de Ciencias Y Filosofía, Universidad Peruana Cayetano Heredia, Lima, Peru.
| | - Jhoel Montoya
- Unidad de Posgrado de la Facultad de Ciencias Biológicas Universidad Nacional Mayor de San Marcos, Lima, Peru
| | - Ana L Rosales Rosas
- Laboratorios de Investigación Y Desarrollo, Facultad de Ciencias Y Filosofía, Universidad Peruana Cayetano Heredia, Lima, Peru
| | - Scarlett Barrientos
- Laboratorios de Investigación Y Desarrollo, Facultad de Ciencias Y Filosofía, Universidad Peruana Cayetano Heredia, Lima, Peru
| | - Anna Rosanas-Urgell
- Department of Biomedical Sciences, Institute of Tropical Medicine, Antwerp, Belgium
| | - Dionicia Gamboa
- Instituto de Medicina Tropical "Alexander von Humboldt" Universidad Peruana Cayetano Heredia, Lima, Peru
- Laboratorios de Investigación Y Desarrollo, Facultad de Ciencias Y Filosofía, Universidad Peruana Cayetano Heredia, Lima, Peru
- Departamento de Ciencias Celulares Y Moleculares, Facultad de Ciencias Y Filosofía, Universidad Peruana Cayetano Heredia, Lima, Peru
| |
Collapse
|
11
|
Choopara I, Suea-Ngam A, Teethaisong Y, Howes PD, Schmelcher M, Leelahavanichkul A, Thunyaharn S, Wongsawaeng D, deMello AJ, Dean D, Somboonna N. Fluorometric Paper-Based, Loop-Mediated Isothermal Amplification Devices for Quantitative Point-of-Care Detection of Methicillin-Resistant Staphylococcus aureus (MRSA). ACS Sens 2021; 6:742-751. [PMID: 33439634 DOI: 10.1021/acssensors.0c01405] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Loop-mediated isothermal amplification (LAMP) has been widely used to detect many infectious diseases. However, minor inconveniences during the steps of adding reaction ingredients and lack of simple color results hinder point-of-care detection. We therefore invented a fluorometric paper-based LAMP by incorporating LAMP reagents, including a biotinylated primer, onto a cellulose membrane paper, with a simple DNA fluorescent dye incubation that demonstrated rapid and accurate results parallel to quantitative polymerase chain reaction (qPCR) methods. This technology allows for instant paper strip detection of methicillin-resistant Staphylococcus aureus (MRSA) in the laboratory and clinical samples. MRSA represents a major public health problem as it can cause infections in different parts of the human body and yet is resistant to commonly used antibiotics. In this study, we optimized LAMP reaction ingredients and incubation conditions following a central composite design (CCD) that yielded the shortest reaction time with high sensitivity. These CCD components and conditions were used to construct the paper-based LAMP reaction by immobilizing the biotinylated primer and the rest of the LAMP reagents to produce the ready-to-use MRSA diagnostic device. Our paper-based LAMP device could detect as low as 10 ag (equivalent to 1 copy) of the MRSA gene mecA within 36-43 min, was evaluated using both laboratory (individual cultures of MRSA and non-MRSA bacteria) and clinical blood samples to be 100% specific and sensitive compared to qPCR results, and had 35 day stability under 25 °C storage. Furthermore, the color readout allows for quantitation of MRSA copies. Hence, this device is applicable for point-of-care MRSA detection.
Collapse
Affiliation(s)
- Ilada Choopara
- Program in Biotechnology, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
| | - Akkapol Suea-Ngam
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, 8093 Zürich, Switzerland
| | - Yothin Teethaisong
- Department of Microbiology, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
| | - Philip D. Howes
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, 8093 Zürich, Switzerland
| | - Mathias Schmelcher
- Department of Health Sciences and Technology, ETH Zürich, 8092 Zürich, Switzerland
| | - Asada Leelahavanichkul
- Department of Microbiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
- Center of Excellence in Immunology and Immune-mediated Diseases, Department of Microbiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
- STAR on Craniofacial and Skeleton Disorders, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
| | - Sudaluck Thunyaharn
- Faculty of Medical Technology, Nakhonratchasima College, Nakhon Ratchasima 30000, Thailand
| | - Doonyapong Wongsawaeng
- Department of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand
| | - Andrew J. deMello
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, 8093 Zürich, Switzerland
| | - Deborah Dean
- Center for Immunobiology and Vaccine Development, UCSF Benioff Children’s Hospital Oakland Research Institute, Oakland, California 94609, United States
- Department of Medicine and Pediatrics, University of California, San Francisco, California 94143, United States
- UC Berkeley/UCSF Graduate Program in Bioengineering, University of California, Berkeley, California 94720, United States
| | - Naraporn Somboonna
- Department of Microbiology, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
- Microbiome Research Unit for Probiotics in Food and Cosmetics, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
12
|
Choopara I, Teethaisong Y, Arunrut N, Thunyaharn S, Kiatpathomchai W, Somboonna N. Specific and sensitive, ready-to-use universal fungi detection by visual color using ITS1 loop-mediated isothermal amplification combined hydroxynaphthol blue. PeerJ 2021; 9:e11082. [PMID: 33777539 PMCID: PMC7982077 DOI: 10.7717/peerj.11082] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 02/17/2021] [Indexed: 12/14/2022] Open
Abstract
Being ubiquitous, fungi are common opportunistic pathogens to humans that can lead to invasive and life-threatening infections in immunocompromised individuals. Eukaryote-resembling cell membrane and filamentous branches make the fungal diagnosis difficult. This study therefore developed a ready-to-use ITS1 loop-mediated isothermal amplification combined with hydroxynaphthol blue (LAMP-HNB) for rapid, sensitive and specific colorimetric detection of universal fungi in all phyla. The ITS1 LAMP-HNB could identify every evolutionary phylum of fungi according to sequence analyses. We tested a total of 30 clinically relevant fungal isolates (representing three major human pathogenic phyla of fungi, namely Zygomycota, Ascomycota and Basidiomycota) and 21 non-fungal isolates, and the ITS1 LAMP-HNB properly identified all isolates, with a detection limit of as low as 4.6 ag (9.6 copies), which was identical to ITS1 and 18S rDNA PCR. The assays were also validated on the feasibility of point-of-care diagnostic with real food (dry peanuts, chili and garlics) and blood samples. Furthermore, the shelf life of our ready-to-use ITS1 LAMP activity (≥50%) was more than 40 days at 30 °C with 3-5% polyvinyl alcohol or glycerol additive. The results supported the ready-to-use ITS1 LAMP-HNB for simple detection of fungi contamination with high sensitivity in local and resource-constrained areas to prevent opportunistic fungal species infections.
Collapse
Affiliation(s)
- Ilada Choopara
- Program in Biotechnology, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
| | - Yothin Teethaisong
- Department of Microbiology, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
| | - Narong Arunrut
- Bioengineering and Sensing Technology Research Team, National Center for Genetic Engineering and Biotechnology, Pathum Thani, Thailand
| | - Sudaluck Thunyaharn
- Faculty of Medical Technology, Nakhonratchasima College, Nakhon Ratchasima, Thailand
| | - Wansika Kiatpathomchai
- Bioengineering and Sensing Technology Research Team, National Center for Genetic Engineering and Biotechnology, Pathum Thani, Thailand
| | - Naraporn Somboonna
- Department of Microbiology, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
- Microbiome Research Unit for Probiotics in Food and Cosmetics, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
13
|
Pumford EA, Lu J, Spaczai I, Prasetyo ME, Zheng EM, Zhang H, Kamei DT. Developments in integrating nucleic acid isothermal amplification and detection systems for point-of-care diagnostics. Biosens Bioelectron 2020; 170:112674. [PMID: 33035900 PMCID: PMC7529604 DOI: 10.1016/j.bios.2020.112674] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 09/30/2020] [Accepted: 09/30/2020] [Indexed: 01/03/2023]
Abstract
Early disease detection through point-of-care (POC) testing is vital for quickly treating patients and preventing the spread of harmful pathogens. Disease diagnosis is generally accomplished using quantitative polymerase chain reaction (qPCR) to amplify nucleic acids in patient samples, permitting detection even at low target concentrations. However, qPCR requires expensive equipment, trained personnel, and significant time. These resources are not available in POC settings, driving researchers to instead utilize isothermal amplification, conducted at a single temperature, as an alternative. Common isothermal amplification methods include loop-mediated isothermal amplification, recombinase polymerase amplification, rolling circle amplification, nucleic acid sequence-based amplification, and helicase-dependent amplification. There has been a growing interest in combining such amplification methods with POC detection methods to enable the development of diagnostic tests that are well suited for resource-limited settings as well as developed countries performing mass screenings. Exciting developments have been made in the integration of these two research areas due to the significant impact that such approaches can have on healthcare. This review will primarily focus on advances made by North American research groups between 2015 and June 2020, and will emphasize integrated approaches that reduce user steps, reliance on expensive equipment, and the system's time-to-result.
Collapse
Affiliation(s)
- Elizabeth A Pumford
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Sciences, University of California, Los Angeles, CA, 90095, USA
| | - Jiakun Lu
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Sciences, University of California, Los Angeles, CA, 90095, USA
| | - Iza Spaczai
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Sciences, University of California, Los Angeles, CA, 90095, USA
| | - Matthew E Prasetyo
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Sciences, University of California, Los Angeles, CA, 90095, USA
| | - Elaine M Zheng
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Sciences, University of California, Los Angeles, CA, 90095, USA
| | - Hanxu Zhang
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Sciences, University of California, Los Angeles, CA, 90095, USA
| | - Daniel T Kamei
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Sciences, University of California, Los Angeles, CA, 90095, USA.
| |
Collapse
|
14
|
Derrick TR, Sandetskaya N, Pickering H, Kölsch A, Ramadhani A, Mafuru E, Massae P, Malisa A, Mtuy T, Burton MJ, Holland MJ, Kuhlmeier D. DjinniChip: evaluation of a novel molecular rapid diagnostic device for the detection of Chlamydia trachomatis in trachoma-endemic areas. Parasit Vectors 2020; 13:533. [PMID: 33109267 PMCID: PMC7590679 DOI: 10.1186/s13071-020-04414-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 10/21/2020] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND The clinical signs of active trachoma are often present in the absence of ocular Chlamydia trachomatis infection, particularly following mass drug administration. Treatment decisions following impact surveys and in post-control surveillance for communities are currently based on the prevalence of clinical signs, which may result in further unnecessary distribution of mass antibiotic treatment and the increased spread of macrolide resistance alleles in 'off-target' bacterial species. We therefore developed a simple, fast, low cost diagnostic assay (DjinniChip) for diagnosis of ocular C. trachomatis for use by trachoma control programmes. METHODS The study was conducted in the UK, Germany and Tanzania. For clinical testing in Tanzania, specimens from a sample of 350 children between the ages of 7 to 15 years, which were part of a longitudinal cohort that began in February 2012 were selected. Two ocular swabs were taken from the right eye. The second swab was collected dry, kept cool in the field and archived at - 80 °C before sample lysis for DjinniChip detection and parallel nucleic acid purification and detection/quantification by qPCR assay. RESULTS DjinniChip was able to reliably detect > 10 copies of C. trachomatis per test and correctly identified 7/10 Quality Control for Molecular Diagnostics C. trachomatis panel samples, failing to detect 3 positive samples with genome equivalent amounts ≤ 10 copies. DjinniChip performed well across a range of typical trachoma field conditions and when used by lay personnel using a series of mock samples. In the laboratory in Tanzania, using clinical samples the sensitivity and specificity of DjinniChip for C. trachomatis was 66% (95% CI 51-78) and 94.8 (95% CI 91-97%) with an overall accuracy of 90.1 (95% CI 86.4-93). CONCLUSIONS DjinniChip performance is extremely promising, particularly its ability to detect low concentrations of C. trachomatis and its usability in field conditions. The DjinniChip requires further development to reduce inhibition and advance toward a closed system. DjinniChip results did not vary between local laboratory results and typical trachoma field settings, illustrating its potential for use in low-resource areas to prevent unnecessary rounds of MDA and to monitor for C. trachomatis recrudescence.
Collapse
Affiliation(s)
- Tamsyn R. Derrick
- Clinical Research Department, London School of Hygiene and Tropical Medicine, London, UK
- Eye Health Project, Kilimanjaro Christian Medical Centre, Moshi, Tanzania
| | - Natalia Sandetskaya
- Department of Diagnostics, Fraunhofer Institute Cell Therapy and Immunology IZI, Leipzig, Germany
| | - Harry Pickering
- Clinical Research Department, London School of Hygiene and Tropical Medicine, London, UK
| | - Andreas Kölsch
- Department of Diagnostics, Fraunhofer Institute Cell Therapy and Immunology IZI, Leipzig, Germany
| | - Athumani Ramadhani
- Eye Health Project, Kilimanjaro Christian Medical Centre, Moshi, Tanzania
| | - Elias Mafuru
- Eye Health Project, Kilimanjaro Christian Medical Centre, Moshi, Tanzania
| | - Patrick Massae
- Eye Health Project, Kilimanjaro Christian Medical Centre, Moshi, Tanzania
| | - Aiweda Malisa
- Eye Health Project, Kilimanjaro Christian Medical Centre, Moshi, Tanzania
| | - Tara Mtuy
- Clinical Research Department, London School of Hygiene and Tropical Medicine, London, UK
- Eye Health Project, Kilimanjaro Christian Medical Centre, Moshi, Tanzania
| | - Matthew J. Burton
- Clinical Research Department, London School of Hygiene and Tropical Medicine, London, UK
| | - Martin J. Holland
- Clinical Research Department, London School of Hygiene and Tropical Medicine, London, UK
| | - Dirk Kuhlmeier
- Department of Diagnostics, Fraunhofer Institute Cell Therapy and Immunology IZI, Leipzig, Germany
| |
Collapse
|
15
|
Srimongkol G, Ditmangklo B, Choopara I, Thaniyavarn J, Dean D, Kokpol S, Vilaivan T, Somboonna N. Rapid colorimetric loop-mediated isothermal amplification for hypersensitive point-of-care Staphylococcus aureus enterotoxin A gene detection in milk and pork products. Sci Rep 2020; 10:7768. [PMID: 32385390 PMCID: PMC7211006 DOI: 10.1038/s41598-020-64710-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 04/17/2020] [Indexed: 01/20/2023] Open
Abstract
Staphylococcus aureus strains carrying enterotoxin A gene (sea) causes food poisoning and cannot be distinguished from non-pathogenic strains by the culture method. Here, we developed a rapid, specific and sensitive visual detection of sea using loop-mediated isothermal amplification (LAMP) combined with nanogold probe (AuNP) or styryl dye (STR). LAMP-AuNP and LAMP-STR can detect as low as 9.7 fg (3.2 sea copies) and 7.2 sea copies, respectively, which were lower than PCR (97 fg or 32 sea copies). The excellent performance of these new assays was demonstrated in food samples using crude DNA lysates. While the culture method detected 104 CFU/g in ground pork and 10 CFU/mL in milk in 5-7 days, LAMP-AuNP could detect down to 10 CFU/g for both samples in 27 minutes. Analyzing 80 pork and milk samples revealed that the LAMP-AuNP showed 100% sensitivity, 97-100% specificity and 97.5-100% accuracy, which were superior to the culture method, and comparable to PCR but without requirement of a thermal cycler. Furthermore, our LAMP-AuNP detect sea at a range below the food safety control (<100 CFU/g). The LAMP-STR quantitated sea in 10-1,000 CFU (7.2-720 copies). Our crude DNA lysis combined with LAMP-AuNP/STR present effective point-of-care detection and facilitate appropriate control strategies.
Collapse
Affiliation(s)
- Grittaya Srimongkol
- Program in Biotechnology, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Boonsong Ditmangklo
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Ilada Choopara
- Program in Biotechnology, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Jiraporn Thaniyavarn
- Department of Microbiology, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Deborah Dean
- Center for Immunobiology and Vaccine Development, UCSF Benioff Children's Hospital Oakland Research Institute, Oakland, CA, 94609, USA
- Department of Medicine, University of California, San Francisco, CA, 94143, USA
- UC Berkeley/UCSF Graduate Program in Bioengineering, University of California, Berkeley, CA, 94720, USA
| | - Sirirat Kokpol
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Tirayut Vilaivan
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Naraporn Somboonna
- Department of Microbiology, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
| |
Collapse
|
16
|
Peng L, Chen JL, Wang D. Progress and Perspectives in Point of Care Testing for Urogenital Chlamydia trachomatis Infection: A Review. Med Sci Monit 2020; 26:e920873. [PMID: 32298243 PMCID: PMC7191959 DOI: 10.12659/msm.920873] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Worldwide, genital infection with Chlamydia trachomatis (C. trachomatis) is one of the most common sexually transmitted infections. Most infections are asymptomatic. However, particularly in women, untreated infection with C. trachomatis can lead to complications that include pelvic inflammatory disease, infertility, and tubal ectopic pregnancy. Rapid methods for early and accurate diagnosis for infection with C. trachomatis that can be performed in the clinic would allow for earlier treatment to prevent complications. Traditional laboratory-based tests for C. trachomatis infection include culture, enzyme immunoassay, direct immunofluorescence, nucleic acid hybridization, and nucleic acid amplification tests, which take time but have high diagnostic sensitivity. Novel and rapid diagnostic tests include extraordinary optical transmission (EOT), loop-mediated isothermal amplification (LAMP), recombinase polymerase amplification (RPA), and microwave-accelerated metal-enhanced fluorescence (MAMEF). Although these new tests offer the promise of rapid screening and diagnosis, they may have lower diagnostic sensitivity. This review aims to provide an overview of traditional methods for the diagnosis of urogenital infection with C. trachomatis, the current status of POC testing for urogenital C. trachomatis infection and discusses recent progress and perspectives.
Collapse
Affiliation(s)
- Liang Peng
- Department of Obstetrics and Gynecology, The Second Xiangya Hospital of Central South University, Changsha, Hunan, China (mainland)
| | - Jian-Lin Chen
- Department of Obstetrics and Gynecology, The Second Xiangya Hospital of Central South University, Changsha, Hunan, China (mainland)
| | - Dao Wang
- Department of Obstetrics and Gynecology, The Second Xiangya Hospital of Central South University, Changsha, Hunan, China (mainland)
| |
Collapse
|
17
|
Simple and visible detection of duck hepatitis B virus in ducks and geese using loop-mediated isothermal amplification. Poult Sci 2020; 99:791-796. [PMID: 32029161 PMCID: PMC7587725 DOI: 10.1016/j.psj.2019.12.024] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Accepted: 10/01/2019] [Indexed: 02/06/2023] Open
Abstract
In this study, loop-mediated isothermal amplification (LAMP) was used to establish a rapid, specific, and visual detection method for duck hepatitis B virus (DHBV). The design and synthesis of 4 specific LAMP primers were based on the conserved gene region of the DHBV genome, and the optimum temperature and time of the LAMP reaction were 63°C and 50 min, respectively. The LAMP assay was confirmed to be specific for DHBV detection and had the same sensitivity as the quantitative PCR assay. A visual detection method for rapid determination of results was developed using a color indicator containing phenol red and cresol red. A color change was produced based on a pH change in the reaction system, indicating a positive reaction. For the detection of samples from ducks and geese, the LAMP method has the advantages of simplicity, high sensitivity and specificity, good visibility, and low cost. Moreover, it is more practical and convenient than PCR-related assays for the clinical detection of DHBV.
Collapse
|
18
|
Reuter C, Slesiona N, Hentschel S, Aehlig O, Breitenstein A, Csáki A, Henkel T, Fritzsche W. Loop-mediated amplification as promising on-site detection approach for Legionella pneumophila and Legionella spp. Appl Microbiol Biotechnol 2019; 104:405-415. [PMID: 31832709 DOI: 10.1007/s00253-019-10286-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 11/08/2019] [Accepted: 11/28/2019] [Indexed: 12/16/2022]
Abstract
Recently Legionella pneumophila is the main causative waterborne organism of severe respiratory infections. Additionally, other Legionella species are documented as human pathogens. In our work, we describe a rapid detection method which combines two advantages for sensitive and specific detection of the genus Legionella: the fast isothermal amplification method "Loop-mediated isothermal AMPlification" (LAMP), and a colorimetric detection method using the metal indicator hydroxynaphtol blue (HBN) which allows to determine an optical signal with a simple readout (with the naked eye). Moreover, we present two approaches for minimizing the assay volume using a stationary microchip LAMP and droplet digital-based LAMP (ddLAMP) as promising highly sensitive setups.
Collapse
Affiliation(s)
- Cornelia Reuter
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany.
| | - Nicole Slesiona
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Stefanie Hentschel
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Oliver Aehlig
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | | | - Andrea Csáki
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Thomas Henkel
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Wolfgang Fritzsche
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| |
Collapse
|
19
|
Zhang M, Ye J, He JS, Zhang F, Ping J, Qian C, Wu J. Visual detection for nucleic acid-based techniques as potential on-site detection methods. A review. Anal Chim Acta 2019; 1099:1-15. [PMID: 31986265 DOI: 10.1016/j.aca.2019.11.056] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 11/21/2019] [Accepted: 11/22/2019] [Indexed: 12/15/2022]
Abstract
Nucleic acid-based techniques could achieve highly sensitive detection by amplifying template molecules to millions of folds. It has been one of the most valued analytical methods and is applied in many detection fields, such as diagnosis of infectious diseases, food safety assurance and so on. Nucleic acid-based techniques consist of three steps: nucleic acid extraction, amplification, and product detection. Among them, the detection step plays a vital role because it shows the results directly. As the trend of detection is simple, rapid and instrument-free, it is of necessity to carry out visual detection, where the result read-out could be visible and distinguished by the naked eye. In this critical review, advanced visual detection methods are summarized and discussed in detail, aiming to promote the potential application in on-site detection.
Collapse
Affiliation(s)
- Mengyao Zhang
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, China
| | - Jing Ye
- Zhijiangnan Think Tank, Zhejiang Institute of Science and Technology Information, Hangzhou, 310006, China
| | - Jin-Song He
- College of Food Science and Technology, Yunnan Agricultural University, Kunming, 650201, China.
| | - Fang Zhang
- College of Biological Science and Engineering, Fuzhou University, Fuzhou, 350108, China
| | - Jianfeng Ping
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, China
| | - Cheng Qian
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, China
| | - Jian Wu
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, China; Key Laboratory of on Site Processing Equipment for Agricultural Products, Ministry of Agriculture, Hangzhou, 310058, China.
| |
Collapse
|
20
|
Point-of-Care Chlamydia trachomatis Detection Using Loop-Mediated Isothermal Amplification and Hydroxynaphthol Blue. Methods Mol Biol 2019; 2042:11-17. [PMID: 31385266 DOI: 10.1007/978-1-4939-9694-0_2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Loop-mediated isothermal amplification (LAMP) is a new nucleic acid amplification technique that provides high sensitivity and specificity compatible to conventional polymerase chain reaction (PCR) and simplicity, without the requirement of an expensive thermal cycler. Additionally, LAMP coupled hydroxynaphthol blue (HNB) allowed for visual color detection by the naked eye. Here we describe the methodology of Chlamydia trachomatis detection of vaginal swab from crude DNA lysis to LAMP-HNB reaction. The result can be read by the naked eye through color change from violet (negative) to sky blue (positive). The result can be confirmed by UV spectra and agarose gel electrophoresis. This assay uses all nonhazardous chemical reagents and is hence safe to the users, and requires little specialist training or knowledge.
Collapse
|
21
|
Wong YP, Othman S, Lau YL, Radu S, Chee HY. Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organisms. J Appl Microbiol 2018; 124:626-643. [PMID: 29165905 PMCID: PMC7167136 DOI: 10.1111/jam.13647] [Citation(s) in RCA: 326] [Impact Index Per Article: 54.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 11/09/2017] [Accepted: 11/13/2017] [Indexed: 12/11/2022]
Abstract
Loop‐mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. (2000Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro‐organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro‐organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real‐time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro‐organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease.
Collapse
Affiliation(s)
- Y-P Wong
- Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Malaysia
| | - S Othman
- Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Malaysia
| | - Y-L Lau
- Department of Parasitology, Faculty of Medicine, Tropical Infectious Diseases Research and Education Centre (TIDREC), University of Malaya, Kuala Lumpur, Malaysia
| | - S Radu
- Centre of Excellence for Food Safety Research (FOSREC), Faculty of Food Science and Technology, Universiti Putra Malaysia, Serdang, Malaysia
| | - H-Y Chee
- Department of Medical Microbiology and Parasitology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Serdang, Malaysia
| |
Collapse
|
22
|
Choopara I, Arunrut N, Kiatpathomchai W, Dean D, Somboonna N. Corrigendum: Rapid and visual Chlamydia trachomatis detection using loop-mediated isothermal amplification and hydroxynaphthol blue. Lett Appl Microbiol 2017; 65:343. [PMID: 28913832 DOI: 10.1111/lam.12786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- I Choopara
- Program in Biotechnology, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
| | - N Arunrut
- Bioengineering and Sensing Technology Laboratory, National Center for Genetic Engineering and Biotechnology, Khlong Nueng, Khlong Luang, Pathum Thani, Thailand
| | - W Kiatpathomchai
- Bioengineering and Sensing Technology Laboratory, National Center for Genetic Engineering and Biotechnology, Khlong Nueng, Khlong Luang, Pathum Thani, Thailand
| | - D Dean
- Center for Immunobiology and Vaccine Development, UCSF Benioff Children's Hospital Oakland Research Institute, Oakland, CA, USA.,Department of Medicine, University of California, San Francisco, CA, USA.,Joint Graduate Program in Bioengineering, University of California, Berkeley, CA, USA
| | - N Somboonna
- Department of Microbiology, Faculty of Science, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
23
|
Jelocnik M, Islam MM, Madden D, Jenkins C, Branley J, Carver S, Polkinghorne A. Development and evaluation of rapid novel isothermal amplification assays for important veterinary pathogens: Chlamydia psittaci and Chlamydia pecorum. PeerJ 2017; 5:e3799. [PMID: 28929022 PMCID: PMC5592900 DOI: 10.7717/peerj.3799] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Accepted: 08/22/2017] [Indexed: 11/20/2022] Open
Abstract
Background Chlamydia psittaci and Chlamydia pecorum are important veterinary pathogens, with the former also being responsible for zoonoses, and the latter adversely affecting koala populations in Australia and livestock globally. The rapid detection of these organisms is still challenging, particularly at the point-of-care (POC). In the present study, we developed and evaluated rapid, sensitive and robust C. psittaci-specific and C. pecorum-specific Loop Mediated Isothermal Amplification (LAMP) assays for detection of these pathogens. Methods and Materials The LAMP assays, performed in a Genie III real-time fluorometer, targeted a 263 bp region of the C. psittaci-specific Cps_0607 gene or a 209 bp region of a C. pecorum-specific conserved gene CpecG_0573, and were evaluated using a range of samples previously screened using species-specific quantitative PCRs (qPCRs). Species-specificity for C. psittaci and C. pecorum LAMP targets was tested against DNA samples from related chlamydial species and a range of other bacteria. In order to evaluate pathogen detection in clinical samples, C. psittaci LAMP was evaluated using a total of 26 DNA extracts from clinical samples from equine and avian hosts, while for C. pecorum LAMP, we tested a total of 63 DNA extracts from clinical samples from koala, sheep and cattle hosts. A subset of 36 C. pecorum samples was also tested in a thermal cycler (instead of a real-time fluorometer) using newly developed LAMP and results were determined as an end point detection. We also evaluated rapid swab processing (without DNA extraction) to assess the robustness of these assays. Results Both LAMP assays were demonstrated to species-specific, highly reproducible and to be able to detect as little as 10 genome copy number/reaction, with a mean amplification time of 14 and 24 min for C. psittaci and C. pecorum, respectively. When testing clinical samples, the overall congruence between the newly developed LAMP assays and qPCR was 92.3% for C. psittaci (91.7% sensitivity and 92.9% specificity); and 84.1% for C. pecorum (90.6% sensitivity and 77.4% specificity). For a subset of 36 C. pecorum samples tested in a thermal cycler using newly developed LAMP, we observed 34/36 (94.4%) samples result being congruent between LAMP performed in fluorometer and in thermal cycler. Rapid swab processing method evaluated in this study also allows for chlamydial DNA detection using LAMP. Discussion In this study, we describe the development of novel, rapid and robust C. psittaci-specific and C. pecorum-specific LAMP assays that are able to detect these bacteria in clinical samples in either the laboratory or POC settings. With further development and a focus on the preparation of these assays at the POC, it is anticipated that both tests may fill an important niche in the repertoire of ancillary diagnostic tools available to clinicians.
Collapse
Affiliation(s)
- Martina Jelocnik
- Centre for Animal Health Innovation, University of the Sunshine Coast, Maroochydore, Queensland, Australia
| | - Md Mominul Islam
- Centre for Animal Health Innovation, University of the Sunshine Coast, Maroochydore, Queensland, Australia
| | - Danielle Madden
- Centre for Animal Health Innovation, University of the Sunshine Coast, Maroochydore, Queensland, Australia
| | - Cheryl Jenkins
- NSW Department of Primary Industries, Elizabeth Macarthur Agricultural Institute, Menangle, New South Wales, Australia
| | - James Branley
- Nepean Hospital, Penrith, New South Wales, Australia
| | - Scott Carver
- School of Biological Sciences, University of Tasmania, Hobart, Tasmania, Australia
| | - Adam Polkinghorne
- Centre for Animal Health Innovation, University of the Sunshine Coast, Maroochydore, Queensland, Australia
| |
Collapse
|
24
|
Butcher R, Houghton J, Derrick T, Ramadhani A, Herrera B, Last AR, Massae PA, Burton MJ, Holland MJ, Roberts CH. Reduced-cost Chlamydia trachomatis-specific multiplex real-time PCR diagnostic assay evaluated for ocular swabs and use by trachoma research programmes. J Microbiol Methods 2017; 139:95-102. [PMID: 28487054 PMCID: PMC5496587 DOI: 10.1016/j.mimet.2017.04.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 04/21/2017] [Accepted: 04/22/2017] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Trachoma, caused by the intracellular bacterium Chlamydia trachomatis (Ct), is the leading infectious cause of preventable blindness. Many commercial platforms are available that provide highly sensitive and specific detection of Ct DNA. However, the majority of these commercial platforms are inaccessible for population-level surveys in resource-limited settings typical to trachoma control programmes. We developed two low-cost quantitative PCR (qPCR) tests for Ct using readily available reagents on standard real-time thermocyclers. METHODS Each multiplex qPCR test targets one genomic and one plasmid Ct target in addition to an endogenous positive control for Homo sapiens DNA. The quantitative performance of the qPCR assays in clinical samples was determined by comparison to a previously evaluated droplet digital PCR (ddPCR) test. The diagnostic performance of the qPCR assays were evaluated against a commercial assay (artus C. trachomatis Plus RG PCR, Qiagen) using molecular diagnostics quality control standards and clinical samples. We examined the yield of Ct DNA prepared from five different DNA extraction kits and a cold chain-free dry-sample preservation method using swabs spiked with fixed concentrations of human and Ct DNA. RESULTS The qPCR assay was highly reproducible (Ct plasmid and genomic targets mean total coefficients of variance 41.5% and 48.3%, respectively). The assay detected 8/8 core specimens upon testing of a quality control panel and performed well in comparison to commercially marketed comparator test (sensitivity and specificity>90%). Optimal extraction and sample preservation methods for research applications were identified. CONCLUSION We describe a pipeline from collection to diagnosis providing the most efficient sample preservation and extraction with significant per test cost savings over a commercial qPCR diagnostic assay. The assay and its evaluation should allow control programs wishing to conduct independent research within the context of trachoma control, access to an affordable test with defined performance characteristics.
Collapse
Affiliation(s)
- Robert Butcher
- Clinical Research Department, Faculty of Infectious and Tropical Diseases, London School of Hygiene & Tropical Medicine, London WC1E 7HT, United Kingdom.
| | - Jo Houghton
- Clinical Research Department, Faculty of Infectious and Tropical Diseases, London School of Hygiene & Tropical Medicine, London WC1E 7HT, United Kingdom
| | - Tamsyn Derrick
- Clinical Research Department, Faculty of Infectious and Tropical Diseases, London School of Hygiene & Tropical Medicine, London WC1E 7HT, United Kingdom; Kilimanjaro Christian Medical Centre, Moshi, Tanzania
| | - Athumani Ramadhani
- Clinical Research Department, Faculty of Infectious and Tropical Diseases, London School of Hygiene & Tropical Medicine, London WC1E 7HT, United Kingdom; Kilimanjaro Christian Medical Centre, Moshi, Tanzania
| | - Beatriz Herrera
- Clinical Research Department, Faculty of Infectious and Tropical Diseases, London School of Hygiene & Tropical Medicine, London WC1E 7HT, United Kingdom
| | - Anna R Last
- Clinical Research Department, Faculty of Infectious and Tropical Diseases, London School of Hygiene & Tropical Medicine, London WC1E 7HT, United Kingdom
| | | | - Matthew J Burton
- Clinical Research Department, Faculty of Infectious and Tropical Diseases, London School of Hygiene & Tropical Medicine, London WC1E 7HT, United Kingdom
| | - Martin J Holland
- Clinical Research Department, Faculty of Infectious and Tropical Diseases, London School of Hygiene & Tropical Medicine, London WC1E 7HT, United Kingdom
| | - Chrissy H Roberts
- Clinical Research Department, Faculty of Infectious and Tropical Diseases, London School of Hygiene & Tropical Medicine, London WC1E 7HT, United Kingdom
| |
Collapse
|