1
|
Zhong B, Qin X, Xu H, Liu L, Li L, Li Z, Cao L, Lou Z, Jackman JA, Cho NJ, Wang L. Interindividual- and blood-correlated sweat phenylalanine multimodal analytical biochips for tracking exercise metabolism. Nat Commun 2024; 15:624. [PMID: 38245507 PMCID: PMC10799919 DOI: 10.1038/s41467-024-44751-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 01/03/2024] [Indexed: 01/22/2024] Open
Abstract
In situ monitoring of endogenous amino acid loss through sweat can provide physiological insights into health and metabolism. However, existing amino acid biosensors are unable to quantitatively assess metabolic status during exercise and are rarely used to establish blood-sweat correlations because they only detect a single concentration indicator and disregard sweat rate. Here, we present a wearable multimodal biochip integrated with advanced electrochemical electrodes and multipurpose microfluidic channels that enables simultaneous quantification of multiple sweat indicators, including phenylalanine and chloride, as well as sweat rate. This combined measurement approach reveals a negative correlation between sweat phenylalanine levels and sweat rates among individuals, which further enables identification of individuals at high metabolic risk. By tracking phenylalanine fluctuations induced by protein intake during exercise and normalizing the concentration indicator by sweat rates to reduce interindividual variability, we demonstrate a reliable method to correlate and analyze sweat-blood phenylalanine levels for personal health monitoring.
Collapse
Affiliation(s)
- Bowen Zhong
- State Key Laboratory for Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Xiaokun Qin
- State Key Laboratory for Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Hao Xu
- State Key Laboratory for Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Lingchen Liu
- State Key Laboratory for Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Linlin Li
- State Key Laboratory for Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Zhexin Li
- State Key Laboratory for Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Limin Cao
- Tianjin Key Laboratory of Lung Cancer Metastasis and Tumor Microenvironment, Tianjin Lung Cancer Institute, Tianjin Medical University General Hospital, Tianjin, 300052, China
| | - Zheng Lou
- State Key Laboratory for Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Joshua A Jackman
- School of Chemical Engineering and Translational Nanobioscience Research Center, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Nam-Joon Cho
- School of Materials Science and Engineering, Nanyang Technological University, 637553, Singapore, Singapore
| | - Lili Wang
- State Key Laboratory for Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, China.
- Center of Materials Science and Optoelectronic Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China.
| |
Collapse
|
2
|
Davis N, Heikenfeld J, Milla C, Javey A. The challenges and promise of sweat sensing. Nat Biotechnol 2024:10.1038/s41587-023-02059-1. [PMID: 38212492 DOI: 10.1038/s41587-023-02059-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 11/07/2023] [Indexed: 01/13/2024]
Abstract
The potential of monitoring biomarkers in sweat for health-related applications has spurred rapid growth in the field of wearable sweat sensors over the past decade. Some of the key challenges have been addressed, including measuring sweat-secretion rate and collecting sufficient sample volumes for real-time, continuous molecular analysis without intense exercise. However, except for assessment of cystic fibrosis and regional nerve function, the ability to accurately measure analytes of interest and their physiological relevance to health metrics remain to be determined. Although sweat is not a crystal ball into every aspect of human health, we expect sweat measurements to continue making inroads into niche applications involving active sweating, such as hydration monitoring for athletes and physical laborers and later for medical and casual health monitoring of relevant drugs and hormones.
Collapse
Affiliation(s)
- Noelle Davis
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, CA, USA
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - Jason Heikenfeld
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA.
- Department of Electrical and Computer Engineering, University of Cincinnati, Cincinnati, OH, USA.
| | - Carlos Milla
- The Stanford Cystic Fibrosis Center, Center for Excellence in Pulmonary Biology, Stanford School of Medicine, Palo Alto, CA, USA.
| | - Ali Javey
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, CA, USA.
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA.
| |
Collapse
|
3
|
Meihua S, Jiahui J, Yujia L, Shuang Z, Jingjing Z. Research on sweat metabolomics of athlete's fatigue induced by high intensity interval training. Front Physiol 2023; 14:1269885. [PMID: 38033334 PMCID: PMC10684900 DOI: 10.3389/fphys.2023.1269885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 11/06/2023] [Indexed: 12/02/2023] Open
Abstract
Objective: Sweat is an important specimen of human metabolism, which can simply and non-invasively monitor the metabolic state of the body, and its metabolites can be used as biomarkers for disease diagnosis, while the changes of sweat metabolites before and after exercise-induced fatigue are still unclear. Methods: In this experiment, high-performance chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS) was used to metabolomic 28 sweat samples before and after exercise-induced fatigue of 14 long-distance runners, also IsoMS PRO and SPSS22.0 software were used to analyze the metabolite changes and differential metabolic pathways. Results: A total of 446 metabolites with high confidence were identified, and the sweat metabolome group before and after high-intensity interval exercise-induced fatigue was obvious, among which the upregulated differential metabolites mainly included hypoxanthine, pyruvate, several amino acids, etc., while the downregulated differential metabolites mainly included amino acid derivatives, vitamin B6, theophylline, etc. Conclusion: The change of hypoxanthine concentration in sweat can be used as a good biomarker for the diagnosis of exercise-induced fatigue, while the change of pyruvate content in sweat can be used as a discriminant index for the energy metabolism mode of the body before and after exercise. The main metabolic pathways involved in differential metabolites produced before and after HIIT exercise-induced fatigue are purine metabolism and amino acid metabolism.
Collapse
Affiliation(s)
- Su Meihua
- School of Physical Education, Jimei University, Xiamen, Fujian, China
| | - Jin Jiahui
- School of Physical Education, Jimei University, Xiamen, Fujian, China
| | - Li Yujia
- School of Physical Education, Jimei University, Xiamen, Fujian, China
| | - Zhao Shuang
- Xiamen Meliomics Technology Co., Ltd., Xiamen, Fujian, China
| | - Zhan Jingjing
- Xiamen Meliomics Technology Co., Ltd., Xiamen, Fujian, China
| |
Collapse
|
4
|
Elpa DP, Raju CM, Chiu HY, Wu SP, Urban PL. Rapid skin biomarker discovery using hydrogel-phase sampling followed by semi-automated liquid-phase re-extraction high-resolution mass spectrometry. Anal Chim Acta 2023; 1252:341028. [PMID: 36935144 DOI: 10.1016/j.aca.2023.341028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/16/2023] [Accepted: 02/26/2023] [Indexed: 03/03/2023]
Abstract
A facile and rapid skin metabolomics protocol is proposed. The liquid microjunction-surface sampling probe system has been partly automated, and used in conjunction with hydrogel probes for skin metabolite analysis. A control device was built to precisely control the segmented solvent flow and analyte re-extraction into the liquid microjunction. This mode provides rapid online re-extraction of the analytes from hydrogel probes. Humectant was added to the hydrogel, and moist heat treatment was used to make the hydrogel probes rugged for sampling in the clinical setting. The developed method was validated for the analysis of choline - a putative biomarker of psoriasis. A linear relationship over six calibration levels from 3.18 × 10-5 to 3.18 × 10-4 mol m-2 has been obtained. The limit of detection was 6.6 × 10-6 mol m-2, while the recoveries range from 92 to 109%. The within-run and between-run precision were evaluated and the coefficients of variation range from 1.84 to 7.13%. Furthermore, the developed method has been used to screen patients (n = 10) and healthy participants (control group; n = 10) for psoriasis-related skin metabolites. Metabolomic profiling of the skin excretion-related signals identified potential biomarkers of psoriasis: choline, pipecolic acid, ornithine, urocanic acid, and methionine.
Collapse
Affiliation(s)
- Decibel P Elpa
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, 1001 University Rd., Hsinchu, 300, Taiwan; Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan
| | - Chamarthi Maheswar Raju
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan
| | - Hsien-Yi Chiu
- Department of Medical Research, National Taiwan University Hospital Hsin-Chu Branch, 25 Jingguo Road, Hsinchu, 300, Taiwan; Department of Dermatology, National Taiwan University Hospital Hsin-Chu Branch, 25 Jingguo Road, Hsinchu, 300, Taiwan; Department of Dermatology, National Taiwan University Hospital, 7 Chung Shan S. Road, Taipei, 100, Taiwan; Department of Dermatology, College of Medicine, National Taiwan University, 1 Jen Ai Road, Taipei, 100, Taiwan.
| | - Shu-Pao Wu
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, 1001 University Rd., Hsinchu, 300, Taiwan.
| | - Pawel L Urban
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan; Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan.
| |
Collapse
|
5
|
Min J, Tu J, Xu C, Lukas H, Shin S, Yang Y, Solomon SA, Mukasa D, Gao W. Skin-Interfaced Wearable Sweat Sensors for Precision Medicine. Chem Rev 2023; 123:5049-5138. [PMID: 36971504 PMCID: PMC10406569 DOI: 10.1021/acs.chemrev.2c00823] [Citation(s) in RCA: 52] [Impact Index Per Article: 52.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
Abstract
Wearable sensors hold great potential in empowering personalized health monitoring, predictive analytics, and timely intervention toward personalized healthcare. Advances in flexible electronics, materials science, and electrochemistry have spurred the development of wearable sweat sensors that enable the continuous and noninvasive screening of analytes indicative of health status. Existing major challenges in wearable sensors include: improving the sweat extraction and sweat sensing capabilities, improving the form factor of the wearable device for minimal discomfort and reliable measurements when worn, and understanding the clinical value of sweat analytes toward biomarker discovery. This review provides a comprehensive review of wearable sweat sensors and outlines state-of-the-art technologies and research that strive to bridge these gaps. The physiology of sweat, materials, biosensing mechanisms and advances, and approaches for sweat induction and sampling are introduced. Additionally, design considerations for the system-level development of wearable sweat sensing devices, spanning from strategies for prolonged sweat extraction to efficient powering of wearables, are discussed. Furthermore, the applications, data analytics, commercialization efforts, challenges, and prospects of wearable sweat sensors for precision medicine are discussed.
Collapse
Affiliation(s)
- Jihong Min
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California, 91125, USA
| | - Jiaobing Tu
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California, 91125, USA
| | - Changhao Xu
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California, 91125, USA
| | - Heather Lukas
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California, 91125, USA
| | - Soyoung Shin
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California, 91125, USA
| | - Yiran Yang
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California, 91125, USA
| | - Samuel A. Solomon
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California, 91125, USA
| | - Daniel Mukasa
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California, 91125, USA
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California, 91125, USA
| |
Collapse
|
6
|
Ladislavová N, Pojmanová P, Vrbka P, Šnupárková J, Urban Š. Human scent signature on cartridge case survives gun being fired: A preliminary study on a potential of scent residues as an identification tool. PLoS One 2023; 18:e0283259. [PMID: 36947531 PMCID: PMC10032514 DOI: 10.1371/journal.pone.0283259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Accepted: 03/03/2023] [Indexed: 03/23/2023] Open
Abstract
This paper focuses on a chemical analysis of human scent samples that were obtained from cartridge cases after being fired and their comparison with scent samples collected under laboratory conditions. Scent samples were analyzed by comprehensive two-dimensional gas chromatography coupled with the time-of-flight mass spectrometer. The results obtained from the chemical analyzes confirmed the desired stability of the human scent evidence and outlined the possible application for forensic purposes. The qualitative results of the study converge with the findings of previous studies on the composition of human scent and the chemical composition of human fingerprints. Furthermore, statistical analyzes were performed employing similarity algorithms such as Pearson's and Spearman's correlations, or Kendall's tau. The resulting comparison of the scent samples secured on fired cartridge cases compared with those samples collected under laboratory conditions yielded ten out of ten correct identifications of the scent inflictor.
Collapse
Affiliation(s)
- Nikola Ladislavová
- Faculty of Chemical Engineering, Department of Analytical Chemistry, UCT Prague, Prague, Czech Republic
| | - Petra Pojmanová
- Faculty of Chemical Engineering, Department of Analytical Chemistry, UCT Prague, Prague, Czech Republic
| | - Pavel Vrbka
- Faculty of Chemical Engineering, Department of Physical Chemistry, UCT Prague, Prague, Czech Republic
| | - Jana Šnupárková
- Faculty of Chemical Engineering, Department of Mathematics, UCT Prague, Prague, Czech Republic
| | - Štěpán Urban
- Faculty of Chemical Engineering, Department of Analytical Chemistry, UCT Prague, Prague, Czech Republic
| |
Collapse
|
7
|
Quantification of chloride in sweat by using ion chromatography instead of chloridometer. SN APPLIED SCIENCES 2022. [DOI: 10.1007/s42452-022-05162-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
AbstractThis study reports about a new ion chromatography method for the detection of chloride ions in sweat as an alternative to the gold standard of the chloridometer. Information about necessary materials, required preparations, reference ranges, advantages and disadvantages of this method is provided. We finally demonstrate that this method is useful to screen for cystic fibrosis in sweat samples.Article Highlights.
A new ion chromatography method for detection of chloride ions in sweat is described
References ranges for this method are given
Advantages and disadvantages are discussed
The usefulness of this method is shown in 145 sweat samples
Collapse
|
8
|
Abstract
In recent years, wearable sensors have enabled the unique mode of real-time and noninvasive monitoring to develop rapidly in medical care, sports, and other fields. Sweat contains a wide range of biomarkers such as metabolites, electrolytes, and various hormones. Combined with wearable technology, sweat can reflect human fatigue, disease, mental stress, dehydration, and so on. This paper comprehensively describes the analysis of sweat components such as glucose, lactic acid, electrolytes, pH, cortisol, vitamins, ethanol, and drugs by wearable sensing technology, and the application of sweat wearable devices in glasses, patches, fabrics, tattoos, and paper. The development trend of sweat wearable devices is prospected. It is believed that if the sweat collection, air permeability, biocompatibility, sensing array construction, continuous monitoring, self-healing technology, power consumption, real-time data transmission, specific recognition, and other problems of the wearable sweat sensor are solved, we can provide the wearer with important information about their health level in the true sense.
Collapse
|
9
|
Pérez D, Orozco J. Wearable electrochemical biosensors to measure biomarkers with complex blood-to-sweat partition such as proteins and hormones. Mikrochim Acta 2022; 189:127. [PMID: 35233646 PMCID: PMC8886869 DOI: 10.1007/s00604-022-05228-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 02/14/2022] [Indexed: 11/24/2022]
Abstract
Smart electronic devices based on micro-controllers, also referred to as fashion electronics, have raised wearable technology. These devices may process physiological information to facilitate the wearer's immediate biofeedback in close contact with the body surface. Standard market wearable devices detect observable features as gestures or skin conductivity. In contrast, the technology based on electrochemical biosensors requires a biomarker in close contact with both a biorecognition element and an electrode surface, where electron transfer phenomena occur. The noninvasiveness is pivotal for wearable technology; thus, one of the most common target tissues for real-time monitoring is the skin. Noninvasive biosensors formats may not be available for all analytes, such as several proteins and hormones, especially when devices are installed cutaneously to measure in the sweat. Processes like cutaneous transcytosis, the paracellular cell–cell unions, or even reuptake highly regulate the solutes content of the sweat. This review discusses recent advances on wearable devices based on electrochemical biosensors for biomarkers with a complex blood-to-sweat partition like proteins and some hormones, considering the commented release regulation mechanisms to the sweat. It highlights the challenges of wearable epidermal biosensors (WEBs) design and the possible solutions. Finally, it charts the path of future developments in the WEBs arena in converging/emerging digital technologies.
Collapse
Affiliation(s)
- David Pérez
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67, Nº 52-20, 050010, Medellín, Colombia.
| | - Jahir Orozco
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67, Nº 52-20, 050010, Medellín, Colombia.
| |
Collapse
|
10
|
Lin PH, Sheu SC, Chen CW, Huang SC, Li BR. Wearable hydrogel patch with noninvasive, electrochemical glucose sensor for natural sweat detection. Talanta 2022; 241:123187. [PMID: 35030501 DOI: 10.1016/j.talanta.2021.123187] [Citation(s) in RCA: 42] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 11/22/2021] [Accepted: 12/26/2021] [Indexed: 12/27/2022]
Abstract
Recent advances in microelectronics and electrochemical sensing platforms have preceded the development of devices for personal monitoring and managing physiological and metabolic information that exploit sweat as a noninvasive, convenient approach for providing information about underlying health conditions, such as glucose level monitoring. Although most sweat glucose sensors have targeted applications during exercise and other active stimulation induced-sweat, natural sweating offers an attractive alternative with minimal effect on users that can be accessed during routine and sedentary activities without impeding personal lifestyle and preserves the correlation between blood and sweat glucose. Here, we present a noninvasive sweat glucose sensor with convenient hydrogel patches for rapid sampling of natural perspiration without external activities that stimulate sweating. The wearable hydrogel patch rapidly takes up natural sweat from the hand and serves as a medium for electrochemical sensing. A prussian blue-doped poly(3,4-ethylenedioxythiophene nanocomposite (PB-PEDOT NC) electrode provides cost-effective, stable and excellent electrocatalytic activity in sweat glucose measurements. We demonstrated sweat glucose sensor functionality by long-term measurements of glucose in sweat from human subjects consuming food and drinks. By enabling the analysis of sweat glucose during routine and sedentary activities, the sweat glucose sensor shows great promise for clinical-grade glucose management and enlarges the scope of next-generation noninvasive sensing systems.
Collapse
Affiliation(s)
- Pei-Heng Lin
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan; Department of Electrical and Computer Engineering, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
| | - Sian-Chen Sheu
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
| | - Chien-Wei Chen
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan; Department of Electrical and Computer Engineering, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan; Taiwan Instrument Research Institute, National Applied Research Laboratories, Hsinchu, Taiwan
| | - Sheng-Cih Huang
- Department of Applied Chemistry, College of Science, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
| | - Bor-Ran Li
- Institute of Biomedical Engineering, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan; Department of Electrical and Computer Engineering, College of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan; Center for Emergent Functional Matter Science, National Yang Ming Chiao Tung University, Hsinchu, Taiwan.
| |
Collapse
|
11
|
Osmotically Enabled Wearable Patch for Sweat Harvesting and Lactate Quantification. MICROMACHINES 2021; 12:mi12121513. [PMID: 34945363 PMCID: PMC8705979 DOI: 10.3390/mi12121513] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 11/28/2021] [Accepted: 12/02/2021] [Indexed: 01/10/2023]
Abstract
Lactate is an essential biomarker for determining the health of the muscles and oxidative stress levels in the human body. However, most of the currently available sweat lactate monitoring devices require external power, cannot measure lactate under low sweat rates (such as in humans at rest), and do not provide adequate information about the relationship between sweat and blood lactate levels. Here, we discuss the on-skin operation of our recently developed wearable sweat sampling patch. The patch combines osmosis (using hydrogel discs) and capillary action (using paper microfluidic channel) for long-term sweat withdrawal and management. When subjects are at rest, the hydrogel disc can withdraw fluid from the skin via osmosis and deliver it to the paper. The lactate amount in the fluid is determined using a colorimetric assay. During active sweating (e.g., exercise), the paper can harvest sweat even in the absence of the hydrogel patch. The captured fluid contains lactate, which we quantify using a colorimetric assay. The measurements show the that the total number of moles of lactate in sweat is correlated to sweat rate. Lactate concentrations in sweat and blood correlate well only during high-intensity exercise. Hence, sweat appears to be a suitable biofluid for lactate quantification. Overall, this wearable patch holds the potential of providing a comprehensive analysis of sweat lactate trends in the human body.
Collapse
|
12
|
Ghaffari R, Yang DS, Kim J, Mansour A, Wright JA, Model JB, Wright DE, Rogers JA, Ray TR. State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics. ACS Sens 2021; 6:2787-2801. [PMID: 34351759 DOI: 10.1021/acssensors.1c01133] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Skin-interfaced wearable systems with integrated colorimetric assays, microfluidic channels, and electrochemical sensors offer powerful capabilities for noninvasive, real-time sweat analysis. This Perspective details recent progress in the development and translation of novel wearable sensors for personalized assessment of sweat dynamics and biomarkers, with precise sampling and real-time analysis. Sensor accuracy, system ruggedness, and large-scale deployment in remote environments represent key opportunity areas, enabling broad deployment in the context of field studies, clinical trials, and recent commercialization. On-body measurements in these contexts show good agreement compared to conventional laboratory-based sweat analysis approaches. These device demonstrations highlight the utility of biochemical sensing platforms for personalized assessment of performance, wellness, and health across a broad range of applications.
Collapse
Affiliation(s)
- Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Da Som Yang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Joohee Kim
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Amer Mansour
- Division of Biological Sciences, The University of Chicago, Chicago, Illinois 60637, United States
| | - John A. Wright
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Jeffrey B. Model
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Donald E. Wright
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - John A. Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
- Departments of Materials Science and Engineering, Mechanical Engineering, Electrical and Computer Engineering, and Chemistry, Northwestern University, Evanston, Illinois 60202, United States
- Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois 60611, United States
| | - Tyler R. Ray
- Department of Mechanical Engineering, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96822, United States
- Department of Cell and Molecular Biology, John A. Burns School of Medicine, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96813, United States
| |
Collapse
|
13
|
Luo TT, Sun ZH, Li CX, Feng JL, Xiao ZX, Li WD. Monitor for lactate in perspiration. J Physiol Sci 2021; 71:26. [PMID: 34445952 PMCID: PMC10717619 DOI: 10.1186/s12576-021-00811-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 08/07/2021] [Indexed: 12/18/2022]
Abstract
Sweat is a noninvasive biological fluid on the surface of human skin and has attracted increasing attention as a diagnostic specimen for disease and biomarker detection. Sweat metabolite quantification is possible due to progress in sweat analysis techniques; nevertheless, the role of sweat monitoring in energy metabolism, physiological or pathological state assessment, health status assessment, and the development and outcome of metabolism-related diseases remains unclear. This review provides a comprehensive overview of the literature on human sweat lactate concentration. The first, second, and third sections of this review present an introduction of sweat lactate, methods for the collection and storage of sweat lactate samples, and methods of detection and analysis of sweat lactate, respectively. The fourth section elaborates upon the current state of clinical application of sweat lactate monitoring and its prospects for health surveillance. The last section focuses on the challenges and future directions of this novel technology for detecting lactate in sweat.
Collapse
Affiliation(s)
- Ting-Ting Luo
- School of Nursing, Institute of Health, Guangdong Pharmaceutical University, Guangzhou, China
| | - Zhong-Hai Sun
- Department of Surgery, The First Affiliated Hospital of Guangdong Pharmaceutical University, Guangzhou, China
| | - Chu-Xin Li
- Department of Thoracic Surgery, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Jin-Lian Feng
- School of Nursing, Institute of Health, Guangdong Pharmaceutical University, Guangzhou, China
| | - Zhao-Xiu Xiao
- Department of Cardiac Surgery, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Wei-Dong Li
- School of Nursing, Institute of Health, Guangdong Pharmaceutical University, Guangzhou, China.
| |
Collapse
|
14
|
Sweat metabolome and proteome: Recent trends in analytical advances and potential biological functions. J Proteomics 2021; 246:104310. [PMID: 34198014 DOI: 10.1016/j.jprot.2021.104310] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 05/31/2021] [Accepted: 06/25/2021] [Indexed: 12/11/2022]
Abstract
Metabolome and proteome profiling of biofluids, e.g., urine, plasma, has generated vast and ever-increasing amounts of knowledge over the last few decades. Paradoxically, omics analyses of sweat, one of the most readily available human biofluids, have lagged behind. This review capitalizes on the current knowledge and state of the art analytical advances of sweat metabolomics and proteomics. Moreover, current applications of sweat omics such as the discovery of disease biomarkers and monitoring athletic performance are also presented in this review. Another area of emerging knowledge that has been highlighted herein lies in the role of skin host-microbiome interactions in shaping the sweat metabolite-protein profiles. Discussion of future research directions describes the need to have a better grasp of sweat chemicals and to better understand how they function as aided by advances in omics tools. Overall, the role of sweat as an information-rich biofluid that could complement the exploration of the skin metabolome/proteome is emphasized.
Collapse
|
15
|
Ghaffari R, Rogers JA, Ray TR. Recent progress, challenges, and opportunities for wearable biochemical sensors for sweat analysis. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 332:129447. [PMID: 33542590 PMCID: PMC7853653 DOI: 10.1016/j.snb.2021.129447] [Citation(s) in RCA: 68] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Sweat is a promising, yet relatively unexplored biofluid containing biochemical information that offers broad insights into the underlying dynamic metabolic activity of the human body. The rich composition of electrolytes, metabolites, hormones, proteins, nucleic acids, micronutrients, and exogenous agents found in sweat dynamically vary in response to the state of health, stress, and diet. Emerging classes of skin-interfaced wearable sensors offer powerful capabilities for the real-time, continuous analysis of sweat produced by the eccrine glands in a manner suitable for use in athletics, consumer wellness, military, and healthcare industries. This perspective examines the rapid and continuous progress of wearable sweat sensors through the most advanced embodiments that address the fundamental challenges currently restricting widespread deployment. It concludes with a discussion of efforts to expand the overall utility of wearable sweat sensors and opportunities for commercialization, in which advances in biochemical sensor technologies will be critically important.
Collapse
Affiliation(s)
- Roozbeh Ghaffari
- -Querrey Simpson Institute for Bioelectronics and Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- -Epicore Biosystems, Inc., Cambridge, MA, USA
| | - John A. Rogers
- -Querrey Simpson Institute for Bioelectronics and Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- -Epicore Biosystems, Inc., Cambridge, MA, USA
- -Departments of Materials Science and Engineering, Mechanical Engineering, Electrical and Computer Engineering, Chemistry, Northwestern University, Evanston, IL, USA
- -Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Tyler R. Ray
- -Department of Mechanical Engineering, University of Hawai‘i at Mānoa, Honolulu, HI
| |
Collapse
|
16
|
LC/MS-based metabolomics to evaluate the milk composition of human, horse, goat and cow from China. Eur Food Res Technol 2021. [DOI: 10.1007/s00217-020-03654-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
17
|
Physiological mechanisms determining eccrine sweat composition. Eur J Appl Physiol 2020; 120:719-752. [PMID: 32124007 PMCID: PMC7125257 DOI: 10.1007/s00421-020-04323-7] [Citation(s) in RCA: 102] [Impact Index Per Article: 25.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 02/11/2020] [Indexed: 02/08/2023]
Abstract
Purpose The purpose of this paper is to review the physiological mechanisms determining eccrine sweat composition to assess the utility of sweat as a proxy for blood or as a potential biomarker of human health or nutritional/physiological status. Methods This narrative review includes the major sweat electrolytes (sodium, chloride, and potassium), other micronutrients (e.g., calcium, magnesium, iron, copper, zinc, vitamins), metabolites (e.g., glucose, lactate, ammonia, urea, bicarbonate, amino acids, ethanol), and other compounds (e.g., cytokines and cortisol). Results Ion membrane transport mechanisms for sodium and chloride are well established, but the mechanisms of secretion and/or reabsorption for most other sweat solutes are still equivocal. Correlations between sweat and blood have not been established for most constituents, with perhaps the exception of ethanol. With respect to sweat diagnostics, it is well accepted that elevated sweat sodium and chloride is a useful screening tool for cystic fibrosis. However, sweat electrolyte concentrations are not predictive of hydration status or sweating rate. Sweat metabolite concentrations are not a reliable biomarker for exercise intensity or other physiological stressors. To date, glucose, cytokine, and cortisol research is too limited to suggest that sweat is a useful surrogate for blood. Conclusion Final sweat composition is not only influenced by extracellular solute concentrations, but also mechanisms of secretion and/or reabsorption, sweat flow rate, byproducts of sweat gland metabolism, skin surface contamination, and sebum secretions, among other factors related to methodology. Future research that accounts for these confounding factors is needed to address the existing gaps in the literature. Electronic supplementary material The online version of this article (10.1007/s00421-020-04323-7) contains supplementary material, which is available to authorized users.
Collapse
|
18
|
Delgado-Povedano MM, Castillo-Peinado LS, Calderón-Santiago M, Luque de Castro MD, Priego-Capote F. Dry sweat as sample for metabolomics analysis. Talanta 2019; 208:120428. [PMID: 31816748 DOI: 10.1016/j.talanta.2019.120428] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 09/27/2019] [Accepted: 10/01/2019] [Indexed: 12/31/2022]
Abstract
Sweat is gaining popularity in clinical metabolomics as this biofluid is non-invasively sampled and its composition is modified by several pathologies. There is a lack of standardized strategies for collection of human sweat. Most studies have been carried out with fresh sweat collected after stimulation. A promising and simple alternative is sampling dry sweat by a solid support impregnated with a suited solvent. This research was aimed at comparing the metabolomics coverage provided by dry sweat collected by two solid supports (gauzes and filter papers) impregnated with different solvents. The dissolved dry sweat was analyzed by a dual approach: gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Among the tested sampling strategies, filter paper impregnated with 1:1 (v/v) ethanol‒phosphate buffer resulted the combination providing the highest metabolomics coverage (tentative identification of one hundred seventy-five compounds). Dry and fresh sweat were compared by using pools from the same individuals to evaluate compositional differences. Families of metabolites such as carnitines, sphingolipids and N-acyl-amino acids, among others, were exclusively identified in dry sweat. Comparison of both samples allowed concluding that dry sweat is better for analysis of low polar metabolites and fresh sweat is more suited for polar compounds. As most of the identified metabolites are involved in key biochemical pathways, this study opens interesting possibilities to the use of dry sweat as a source of metabolite markers for specific disorders. Sampling of dry sweat could provide a standardized approach for collection of this biofluid, thus overcoming the variability limitations of fresh sweat.
Collapse
Affiliation(s)
- M M Delgado-Povedano
- Department of Analytical Chemistry, Annex Marie Curie Building, Campus of Rabanales, University of Córdoba, Córdoba, Spain; Nanochemistry Research Institute, University of Córdoba, Córdoba, Spain; Maimónides Institute of Biomedical Research (IMIBIC), Reina Sofía University Hospital, Córdoba, Spain; CIBER Fragilidad y Envejecimiento Saludable (CIBERfes), Instituto de Salud Carlos III, Spain
| | - L S Castillo-Peinado
- Department of Analytical Chemistry, Annex Marie Curie Building, Campus of Rabanales, University of Córdoba, Córdoba, Spain; Nanochemistry Research Institute, University of Córdoba, Córdoba, Spain; Maimónides Institute of Biomedical Research (IMIBIC), Reina Sofía University Hospital, Córdoba, Spain; CIBER Fragilidad y Envejecimiento Saludable (CIBERfes), Instituto de Salud Carlos III, Spain
| | - M Calderón-Santiago
- Department of Analytical Chemistry, Annex Marie Curie Building, Campus of Rabanales, University of Córdoba, Córdoba, Spain; Nanochemistry Research Institute, University of Córdoba, Córdoba, Spain; Maimónides Institute of Biomedical Research (IMIBIC), Reina Sofía University Hospital, Córdoba, Spain; CIBER Fragilidad y Envejecimiento Saludable (CIBERfes), Instituto de Salud Carlos III, Spain
| | - M D Luque de Castro
- Department of Analytical Chemistry, Annex Marie Curie Building, Campus of Rabanales, University of Córdoba, Córdoba, Spain; Nanochemistry Research Institute, University of Córdoba, Córdoba, Spain; Maimónides Institute of Biomedical Research (IMIBIC), Reina Sofía University Hospital, Córdoba, Spain; CIBER Fragilidad y Envejecimiento Saludable (CIBERfes), Instituto de Salud Carlos III, Spain.
| | - F Priego-Capote
- Department of Analytical Chemistry, Annex Marie Curie Building, Campus of Rabanales, University of Córdoba, Córdoba, Spain; Nanochemistry Research Institute, University of Córdoba, Córdoba, Spain; Maimónides Institute of Biomedical Research (IMIBIC), Reina Sofía University Hospital, Córdoba, Spain; CIBER Fragilidad y Envejecimiento Saludable (CIBERfes), Instituto de Salud Carlos III, Spain.
| |
Collapse
|
19
|
Harshman SW, Pitsch RL, Schaeublin NM, Smith ZK, Strayer KE, Phelps MS, Qualley AV, Cowan DW, Rose SD, O'Connor ML, Eckerle JJ, Das T, Barbey AK, Strang AJ, Martin JA. Metabolomic stability of exercise-induced sweat. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1126-1127:121763. [DOI: 10.1016/j.jchromb.2019.121763] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 07/12/2019] [Accepted: 08/08/2019] [Indexed: 12/15/2022]
|
20
|
Baker LB. Physiology of sweat gland function: The roles of sweating and sweat composition in human health. Temperature (Austin) 2019; 6:211-259. [PMID: 31608304 PMCID: PMC6773238 DOI: 10.1080/23328940.2019.1632145] [Citation(s) in RCA: 231] [Impact Index Per Article: 46.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 06/06/2019] [Accepted: 06/08/2019] [Indexed: 12/21/2022] Open
Abstract
The purpose of this comprehensive review is to: 1) review the physiology of sweat gland function and mechanisms determining the amount and composition of sweat excreted onto the skin surface; 2) provide an overview of the well-established thermoregulatory functions and adaptive responses of the sweat gland; and 3) discuss the state of evidence for potential non-thermoregulatory roles of sweat in the maintenance and/or perturbation of human health. The role of sweating to eliminate waste products and toxicants seems to be minor compared with other avenues of excretion via the kidneys and gastrointestinal tract; as eccrine glands do not adapt to increase excretion rates either via concentrating sweat or increasing overall sweating rate. Studies suggesting a larger role of sweat glands in clearing waste products or toxicants from the body may be an artifact of methodological issues rather than evidence for selective transport. Furthermore, unlike the renal system, it seems that sweat glands do not conserve water loss or concentrate sweat fluid through vasopressin-mediated water reabsorption. Individuals with high NaCl concentrations in sweat (e.g. cystic fibrosis) have an increased risk of NaCl imbalances during prolonged periods of heavy sweating; however, sweat-induced deficiencies appear to be of minimal risk for trace minerals and vitamins. Additional research is needed to elucidate the potential role of eccrine sweating in skin hydration and microbial defense. Finally, the utility of sweat composition as a biomarker for human physiology is currently limited; as more research is needed to determine potential relations between sweat and blood solute concentrations.
Collapse
Affiliation(s)
- Lindsay B Baker
- Gatorade Sports Science Institute, PepsiCo R&D Physiology and Life Sciences, Barrington, IL, USA
| |
Collapse
|
21
|
Li R, Hao R, Zhu Y. Steam radish sprout (
Raphanus sativus
L.): active substances, antioxidant activities and non‐targeted metabolomics analysis. Int J Food Sci Technol 2019. [DOI: 10.1111/ijfs.14233] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Ru Li
- College of Food Science & Nutritional Engineering China Agricultural University No. 17 Qinghua East Rd Beijing 100083China
| | - Rui Hao
- College of Food Science & Nutritional Engineering China Agricultural University No. 17 Qinghua East Rd Beijing 100083China
| | - Yi Zhu
- College of Food Science & Nutritional Engineering China Agricultural University No. 17 Qinghua East Rd Beijing 100083China
| |
Collapse
|