1
|
Gomes Torres ACMB, Mathias C, Baal SCS, Kohler AF, Cunha ML, Blanes L. Advancements in LAMP-Based Diagnostics: Emerging Techniques and Applications in Viral Detection with a Focus on Herpesviruses in Transplant Patient Management. Int J Mol Sci 2024; 25:11506. [PMID: 39519059 PMCID: PMC11546353 DOI: 10.3390/ijms252111506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2024] [Revised: 10/22/2024] [Accepted: 10/23/2024] [Indexed: 11/16/2024] Open
Abstract
Loop-mediated isothermal amplification (LAMP) is a highly effective molecular diagnostic technique, particularly advantageous for point-of-care (POC) settings. In recent years, LAMP has expanded to include various adaptations such as DARQ-LAMP, QUASR, FLOS-LAMP, displacement probes and molecular beacons. These methods enable multiplex detection of multiple targets in a single reaction, enhancing cost-effectiveness and diagnostic efficiency. Consequently, LAMP has gained significant traction in diagnosing diverse viruses, notably during the COVID-19 pandemic. However, its application for detecting Herpesviridae remains relatively unexplored. This group of viruses is of particular interest due to their latency and potential reactivation, crucial for immunocompromised patients, including organ and hematopoietic stem cell transplant recipients. This review highlights recent advancements in LAMP for virus diagnosis and explores current research trends and future prospects, emphasizing the detection challenges posed by Herpesviridae.
Collapse
Affiliation(s)
| | - Carolina Mathias
- Post-Graduation Program in Genetics, Department of Genetics, Federal University of Parana, Curitiba 81530-980, Brazil; (C.M.); (S.C.S.B.); (A.F.K.); (M.L.C.)
| | - Suelen Cristina Soares Baal
- Post-Graduation Program in Genetics, Department of Genetics, Federal University of Parana, Curitiba 81530-980, Brazil; (C.M.); (S.C.S.B.); (A.F.K.); (M.L.C.)
| | - Ana Flávia Kohler
- Post-Graduation Program in Genetics, Department of Genetics, Federal University of Parana, Curitiba 81530-980, Brazil; (C.M.); (S.C.S.B.); (A.F.K.); (M.L.C.)
| | - Mylena Lemes Cunha
- Post-Graduation Program in Genetics, Department of Genetics, Federal University of Parana, Curitiba 81530-980, Brazil; (C.M.); (S.C.S.B.); (A.F.K.); (M.L.C.)
| | - Lucas Blanes
- Laboratory for Applied Science and Technology in Health, Carlos Chagas Institute, Oswaldo Cruz Foundation (Fiocruz), Curitiba 81350-010, Brazil;
| |
Collapse
|
2
|
Edwards N, Reboud J, Yan X, Guo X, Cooper JM, Wadsworth J, Waters R, Mioulet V, King DP, Shaw AE. Detection of foot-and-mouth disease virus RNA using a closed loop-mediated isothermal amplification system. Front Microbiol 2024; 15:1429288. [PMID: 39188314 PMCID: PMC11346313 DOI: 10.3389/fmicb.2024.1429288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Accepted: 07/18/2024] [Indexed: 08/28/2024] Open
Abstract
Foot-and-mouth disease (FMD) is a highly contagious viral disease of cloven-hoofed animals responsible for economic losses that amount to >$20 billion annually. Rapid recognition of FMD cases provides vital information to guide control programmes. A range of point-of-need amplification technologies have been developed which allow sensitive detection of the causative virus (FMDV) in the field at locations remote from laboratories. Here we describe a novel system to detect FMDV RNA using loop-mediated isothermal amplification (LAMP). This test was evaluated using a panel of FMDV isolates (n = 79) and RNA standards demonstrating capability to amplify viral genome directly from clinical material in the absence of nucleic acid extraction. This extraction-free RT-LAMP assay was transferred to a bespoke closed-system lateral flow test (LFT) that was used in combination with a low-cost hand-held heater. Our results show that the RT-LAMP-LFT assay retains a high level of diagnostic and analytical sensitivity when using direct clinical material, with a limit of detection under 80 copies per reaction. Together, our data support the potential for the use of this assay at the point-of-need to facilitate rapid feedback on the status of suspect cases.
Collapse
Affiliation(s)
| | - Julien Reboud
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Glasgow, United Kingdom
| | - Xiaoxiang Yan
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Glasgow, United Kingdom
| | - Xin Guo
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Glasgow, United Kingdom
| | - Jonathan M. Cooper
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Glasgow, United Kingdom
| | | | - Ryan Waters
- The Pirbright Institute, Woking, United Kingdom
| | | | | | | |
Collapse
|
3
|
Shen H, Yang D, Li X, Ju H, Ge F, Yang X, Wang J, Xia L, Zhao H, Jiang P. Comparison of dye-based and probe-based RT-LAMP in detection of canine astrovirus. Arch Virol 2024; 169:21. [PMID: 38194148 DOI: 10.1007/s00705-023-05913-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 09/13/2023] [Indexed: 01/10/2024]
Abstract
A rapid and sensitive assay is essential for reliable surveillance and diagnosis of canine astrovirus (CaAstV). In this study, two real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays with high sensitivity, rapidity, and reliability were developed using fluorescence dye and FRET-based assimilating probes for real-time detection of CaAstV. These assays specifically amplified the ORF2 gene of CaAstV and did not amplify any sequences from canine enterovirus. The limit of detection (LOD) of both the probe-based and dye-based RT-LAMPs was 100 copies/μL. Fluorescence signals were generated within 30 min for the lowest concentration of a standard RNA sample, which was significantly faster than that achieved by real-time fluorescence quantitative PCR (qRT-PCR) assay. When clinical samples were tested, the positive and negative agreement of the dye-based RT-LAMP assay with qRT-PCR was 87.5% (14/16) and 93.55% (29/31), respectively. The positive and negative agreement of the probe-based RT-LAMP assay with qRT-PCR was 94.11% (16/17) and 96.55% (28/29), respectively. The RT-LAMP assays developed in this study showed strong potential for use as an on-site diagnostic assay for rapid, specific, and reliable detection of CaAstV in clinical samples.
Collapse
Affiliation(s)
- Haixiao Shen
- Shanghai Animal Disease Control Center, Shanghai, China
- Key Laboratory of Animal Diseases Diagnostic and Immunology, Ministry of Agriculture, MOE International Joint Collaborative Research Laboratory for Animal Health and Food Safety, College of Veterinary Medicine, Nanjing Agricultural University, Nanjing, China
| | - Dequan Yang
- Shanghai Animal Disease Control Center, Shanghai, China
| | - Xin Li
- Shanghai Animal Disease Control Center, Shanghai, China
| | - Houbin Ju
- Shanghai Animal Disease Control Center, Shanghai, China
| | - Feifei Ge
- Shanghai Animal Disease Control Center, Shanghai, China
| | - Xianchao Yang
- Shanghai Animal Disease Control Center, Shanghai, China
| | - Jian Wang
- Shanghai Animal Disease Control Center, Shanghai, China
| | - Luming Xia
- Shanghai Animal Disease Control Center, Shanghai, China
| | - Hongjin Zhao
- Shanghai Animal Disease Control Center, Shanghai, China.
| | - Ping Jiang
- Key Laboratory of Animal Diseases Diagnostic and Immunology, Ministry of Agriculture, MOE International Joint Collaborative Research Laboratory for Animal Health and Food Safety, College of Veterinary Medicine, Nanjing Agricultural University, Nanjing, China.
| |
Collapse
|
4
|
Kim HR, Kim JM, Baek JS, Park J, Kim WI, Ku BK, Jeoung HY, Lee KK, Park CK. An Advanced Multiplex Real-Time Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Rapid and Reliable Detection of Porcine Epidemic Diarrhea Virus and Porcine Internal Positive Control. Viruses 2023; 15:2204. [PMID: 38005882 PMCID: PMC10674262 DOI: 10.3390/v15112204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 10/30/2023] [Accepted: 10/31/2023] [Indexed: 11/26/2023] Open
Abstract
For rapid and reliable detection of porcine epidemic diarrhea virus (PEDV) from pig clinical samples, a multiplex, real-time, reverse transcription loop-mediated isothermal amplification (mqRT-LAMP) was developed using two sets of primers and assimilating probes specific to the PEDV N gene and the Sus scrofa β-actin gene, which was used as an endogenous internal positive control (EIPC) to avoid false-negative results. The assay specifically amplified both target genes of PEDV and EIPC in a single reaction without any interference but did not amplify other porcine viral nucleic acids. The limit of detection was 10 copies/μL, 100-fold lower than that of a reverse transcription-polymerase chain reaction (RT-PCR) and equivalent to that of quantitative/real-time RT-PCR (qRT-PCR). This assay has high repeatability and reproducibility with coefficients of variation < 4.0%. The positive signal of the mqRT-LAMP assay was generated within 25 min, demonstrating advantages in rapid detection of PEDV over RT-PCR or qRT-PCR assay, which require at least 2 h turnaround times. In clinical evaluation, the detection rate of PEDV by mqRT-LAMP assay (77.3%) was higher than that of RT-PCR assay (69.7%), and comparable to qRT-PCR (76.8%) with almost 100% concordance (kappa value 0.98). The developed mqRT-LAMP assay can serve as an advanced alternative method for PEDV diagnosis because it has high sensitivity and specificity, rapidity, and reliability even in resource-limited laboratories.
Collapse
Affiliation(s)
- Hye-Ryung Kim
- College of Veterinary Medicine & Institute for Veterinary Biomedical Science, Kyungpook National University, Daegu 41566, Republic of Korea; (H.-R.K.); (J.-M.K.); (J.-S.B.); (J.P.)
| | - Jong-Min Kim
- College of Veterinary Medicine & Institute for Veterinary Biomedical Science, Kyungpook National University, Daegu 41566, Republic of Korea; (H.-R.K.); (J.-M.K.); (J.-S.B.); (J.P.)
| | - Ji-Su Baek
- College of Veterinary Medicine & Institute for Veterinary Biomedical Science, Kyungpook National University, Daegu 41566, Republic of Korea; (H.-R.K.); (J.-M.K.); (J.-S.B.); (J.P.)
| | - Jonghyun Park
- College of Veterinary Medicine & Institute for Veterinary Biomedical Science, Kyungpook National University, Daegu 41566, Republic of Korea; (H.-R.K.); (J.-M.K.); (J.-S.B.); (J.P.)
| | - Won-Il Kim
- College of Veterinary Medicine, Jeonbuk National University, Iksan 54596, Republic of Korea;
| | - Bok Kyung Ku
- Animal and Plant Quarantine Agency, Gyeongsangbuk-do, Gimcheon 39660, Republic of Korea; (B.K.K.); (H.-Y.J.); (K.-K.L.)
| | - Hye-Young Jeoung
- Animal and Plant Quarantine Agency, Gyeongsangbuk-do, Gimcheon 39660, Republic of Korea; (B.K.K.); (H.-Y.J.); (K.-K.L.)
| | - Kyoung-Ki Lee
- Animal and Plant Quarantine Agency, Gyeongsangbuk-do, Gimcheon 39660, Republic of Korea; (B.K.K.); (H.-Y.J.); (K.-K.L.)
| | - Choi-Kyu Park
- College of Veterinary Medicine & Institute for Veterinary Biomedical Science, Kyungpook National University, Daegu 41566, Republic of Korea; (H.-R.K.); (J.-M.K.); (J.-S.B.); (J.P.)
| |
Collapse
|
5
|
Ayaz Kök S, Üstün S, Taşkent Sezgin H. Diagnosis of Ruminant Viral Diseases with Loop-Mediated Isothermal Amplification. Mol Biotechnol 2023; 65:1228-1241. [PMID: 36719638 PMCID: PMC9888337 DOI: 10.1007/s12033-023-00674-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 01/16/2023] [Indexed: 02/01/2023]
Abstract
Infectious diseases in livestock industry are major problems for animal health, food safety, and the economy. Zoonotic diseases from farm animals are significant threat to human population as well. These are notifiable diseases listed by the World Organization for Animal Health (OIE). Rapid diagnostic methods can help keep infectious diseases under control in herds. Loop-mediated isothermal amplification (LAMP) is a simple and rapid nucleic acid amplification method that is studied widely for detection of many infectious diseases in the field. LAMP allows biosensing of target DNA or RNA under isothermal conditions with high specificity in a short period of time. An untrained user can analyze results based on color change or turbidity. Here we review LAMP assays to diagnose OIE notifiable ruminant viral diseases in literature highlighting properties of LAMP method considering what is expected from an efficient, field usable diagnostic test.
Collapse
Affiliation(s)
- Sanem Ayaz Kök
- Biotechnology Interdisciplinary Program, İzmir Institute of Technology, Gülbahçe, Urla, İzmir, Turkey, 35430
- New Era Biotechnology, Teknopark İzmir, Gülbahçe, Urla, İzmir, Turkey, 35430
| | - Selcen Üstün
- Bioengineering Department, İzmir Institute of Technology, Gülbahçe, Urla, İzmir, Turkey, 35430
| | - Hümeyra Taşkent Sezgin
- Biotechnology Interdisciplinary Program, İzmir Institute of Technology, Gülbahçe, Urla, İzmir, Turkey, 35430.
- New Era Biotechnology, Teknopark İzmir, Gülbahçe, Urla, İzmir, Turkey, 35430.
- Bioengineering Department, İzmir Institute of Technology, Gülbahçe, Urla, İzmir, Turkey, 35430.
| |
Collapse
|
6
|
Zhang X, Zhao Y, Zeng Y, Zhang C. Evolution of the Probe-Based Loop-Mediated Isothermal Amplification (LAMP) Assays in Pathogen Detection. Diagnostics (Basel) 2023; 13:diagnostics13091530. [PMID: 37174922 PMCID: PMC10177487 DOI: 10.3390/diagnostics13091530] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 04/19/2023] [Accepted: 04/23/2023] [Indexed: 05/15/2023] Open
Abstract
Loop-mediated isothermal amplification (LAMP), as the rank one alternative to a polymerase chain reaction (PCR), has been widely applied in point-of-care testing (POCT) due to its rapid, simple, and cost-effective characteristics. However, it is difficult to achieve real-time monitoring and multiplex detection with the traditional LAMP method. In addition, these approaches that use turbidimetry, sequence-independent intercalating dyes, or pH-sensitive indicators to indirectly reflect amplification can result in false-positive results if non-specific amplification occurs. To fulfill the needs of specific target detection and one-pot multiplex detection, a variety of probe-based LAMP assays have been developed. This review focuses on the principles of these assays, summarizes their applications in pathogen detection, and discusses their features and advantages over the traditional LAMP methods.
Collapse
Affiliation(s)
- Xiaoling Zhang
- Shanghai Public Health Clinical Center, Fudan University, Shanghai 201508, China
| | - Yongjuan Zhao
- Shanghai Public Health Clinical Center, Fudan University, Shanghai 201508, China
| | - Yi Zeng
- Shanghai Public Health Clinical Center, Fudan University, Shanghai 201508, China
| | - Chiyu Zhang
- Shanghai Public Health Clinical Center, Fudan University, Shanghai 201508, China
| |
Collapse
|
7
|
Zhao Y, Zeng Y, Lu R, Wang Z, Zhang X, Wu N, Zhu T, Wang Y, Zhang C. Rapid point-of-care detection of BK virus in urine by an HFman probe-based loop-mediated isothermal amplification assay and a finger-driven microfluidic chip. PeerJ 2023; 11:e14943. [PMID: 36915661 PMCID: PMC10007963 DOI: 10.7717/peerj.14943] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 02/01/2023] [Indexed: 03/16/2023] Open
Abstract
Background BK virus (BKV)-associated nephropathy (BKVN) is one of the leading causes of renal dysfunction and graft loss in renal transplant recipients. Early monitoring of BKV in urine is crucial to minimize the deleterious effects caused by this virus on preservation of graft function. Methods We report a simple, rapid, sensitive loop-mediated isothermal amplification (LAMP) assay using an HFman probe for detecting BKV in urine. To evaluate the performance of the assay, a comparison of the HFman probe-based LAMP (HF-LAMP) assay with two qPCR assays was performed using urine samples from 132 HIV-1 infected individuals. We further evaluated the performance of HF-LAMP directly using the urine samples from these HIV-1 infected individuals and 30 kidney transplant recipients without DNA extraction. Furthermore, we combined the HF-LAMP assay with a portable finger-driven microfluidic chip for point-of-care testing (POCT). Results The assay has high specificity and sensitivity with a limit of detection (LOD) of 12 copies/reaction and can be completed within 30 min. When the DNA was extracted, the HF-LAMP assay showed an equivalent and potentially even higher sensitivity (93.5%) than the qPCR assays (74.2-87.1%) for 132 urine samples from HIV-1 infected individuals. The HF-LAMP assay can be applied in an extraction-free format and can be completed within 45 min using a simple heat block. Although some decreased performance was seen on urine samples from HIV-1 infected individuals, the sensitivity, specificity, and accuracy of the extraction-free BKV HF-LAMP assay were 95%, 100%, and 96.7% for 30 clinical urine samples from kidney transplant recipients, respectively. Conclusion The assay has high specificity and sensitivity. Combined with a portable finger-driven microfluidic chip for easy detection, this method shows great potential for POCT detection of BKV.
Collapse
Affiliation(s)
- Yongjuan Zhao
- Shanghai Public Health Clinical Center, Shanghai, China
| | - Yi Zeng
- Shanghai Public Health Clinical Center, Shanghai, China
| | - Renfei Lu
- Nantong Third Hospital Affiliated to Nantong University, Nantong, China
| | - Zhiying Wang
- Beijing Advanced Innovation Center for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology, School of Engineering Medicine, Beihang University, Beijing, China
| | | | - Nannan Wu
- Shanghai Public Health Clinical Center, Shanghai, China
| | - Tongyu Zhu
- Shanghai Medical College, Shanghai, China.,Zhongshan Hospital, Shanghai, China
| | - Yang Wang
- Beijing Advanced Innovation Center for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology, School of Engineering Medicine, Beihang University, Beijing, China
| | - Chiyu Zhang
- Shanghai Public Health Clinical Center, Shanghai, China
| |
Collapse
|
8
|
Chen W, Wang W, Wang X, Li Z, Wu K, Li X, Li Y, Yi L, Zhao M, Ding H, Fan S, Chen J. Advances in the differential molecular diagnosis of vesicular disease pathogens in swine. Front Microbiol 2022; 13:1019876. [PMID: 36386633 PMCID: PMC9641196 DOI: 10.3389/fmicb.2022.1019876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 09/30/2022] [Indexed: 11/23/2022] Open
Abstract
Foot-and-mouth disease virus (FMDV), Senecavirus A (SVA) and swine vesicular disease virus (SVDV) are members of the family Picornaviridae, which can cause similar symptoms - vesicular lesions in the tissues of the mouth, nose, feet, skin and mucous membrane of animals. Rapid and accurate diagnosis of these viruses allows for control measures to prevent the spread of these diseases. Reverse transcription-polymerase chain reaction (RT-PCR) and real-time RT-PCR are traditional and reliable methods for pathogen detection, while their amplification reaction requires a thermocycler. Isothermal amplification methods including loop-mediated isothermal amplification and recombinase polymerase amplification developed in recent years are simple, rapid and do not require specialized equipment, allowing for point of care diagnostics. Luminex technology allows for simultaneous detection of multiple pathogens. CRISPR-Cas diagnostic systems also emerging nucleic acid detection technologies which are very sensitivity and specificity. In this paper, various nucleic acid detection methods aimed at vesicular disease pathogens in swine (including FMDV, SVA and SVDV) are summarized.
Collapse
Affiliation(s)
- Wenxian Chen
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| | - Weijun Wang
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| | - Xinyan Wang
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| | - Zhaoyao Li
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| | - Keke Wu
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| | - Xiaowen Li
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
| | - Yuwan Li
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
- Key Laboratory of Zoonosis Prevention and Control of Guangdong Province, Guangzhou, China
| | - Lin Yi
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
- Key Laboratory of Zoonosis Prevention and Control of Guangdong Province, Guangzhou, China
| | - Mingqiu Zhao
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
- Key Laboratory of Zoonosis Prevention and Control of Guangdong Province, Guangzhou, China
| | - Hongxing Ding
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
- Key Laboratory of Zoonosis Prevention and Control of Guangdong Province, Guangzhou, China
| | - Shuangqi Fan
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
- *Correspondence: Shuangqi Fan, ; Jinding Chen,
| | - Jinding Chen
- College of Veterinary Medicine, South China Agricultural University, Guangzhou, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou, China
- *Correspondence: Shuangqi Fan, ; Jinding Chen,
| |
Collapse
|
9
|
Zhang J, Hou Q, Ma W, Chen D, Zhang W, Wubshet AK, Ding Y, Li M, Li Q, Chen J, Dai J, Wu G, Zhang Z, Zaberezhny AD, Pejsak Z, Tarasiuk K, Zafar Khan MU, Wang Y, He J, Liu Y. A Naked-Eye Visual Reverse Transcription Loop-Mediated Isothermal Amplification with Sharp Color Changes for Potential Pen-Side Test of Foot-and-Mouth Disease Virus. Viruses 2022; 14:v14091982. [PMID: 36146788 PMCID: PMC9504329 DOI: 10.3390/v14091982] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 08/28/2022] [Accepted: 08/30/2022] [Indexed: 11/17/2022] Open
Abstract
Visual loop-mediated isothermal amplification (LAMP) is qualified to be applied in the field to detect pathogens due to its simplicity, rapidity and cost saving. However, the color changes in currently reported visual reverse transcription LAMP (RT-LAMP) for foot-and-mouth disease virus (FMDV) detection are not so obvious to the naked eye, so interpretation of results is troublesome. In this study, a new naked-eye visual RT-LAMP to detect all seven distinct serotypes of FMDV was established based on the 3D genes by using pH-sensitive neutral red as the indicator, rendering a sharp contrast of color changes between the negative (light orange) and the positive (pink). Analytical sensitivity tests showed that the detection limit of the visual RT-LAMP was 104 copies/µL while those were 103 and 104 copies/µL for the RT-qPCR and conventional RT-PCR methods, respectively. Specificity tests proved that the established visual RT-LAMP assay had no cross-reactivity with other common livestock viruses. Furthermore, the analysis of 59 clinical samples showed 98.31% and 100% concordance with the RT-qPCR and the RT-PCR, respectively. The pan-serotypic FMD visual RT-LAMP assay could be suitable for a pen-side test of all seven serotypes of FMDV because the results could be easily distinguished by the naked eye without the requirement of complicated instruments and professional technicians. Hence, the novel method may have a promising prospect in field tests which exert an important role in monitoring, preventing, and controlling FMD, especially in regions with no PCR or qPCR instrument available.
Collapse
Affiliation(s)
- Jie Zhang
- Hebei Key Laboratory of Preventive Veterinary Medicine, College of Animal Science and Technology, Hebei Normal University of Science & Technology, Qinhuangdao 066004, China
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Qian Hou
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Weimin Ma
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Danian Chen
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Weibing Zhang
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Ashenafi Kiros Wubshet
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Yaozhong Ding
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Miaomiao Li
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Qian Li
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Jiao Chen
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Junfei Dai
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Guohua Wu
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Ziteng Zhang
- Hebei Key Laboratory of Preventive Veterinary Medicine, College of Animal Science and Technology, Hebei Normal University of Science & Technology, Qinhuangdao 066004, China
| | - Alexei D. Zaberezhny
- Federal State Budgetary Institution, All-Russian Research and Technological Institute of Biological Industry (VNITIBP), Moscow 141142, Russia
| | - Zygmunt Pejsak
- Department of Infectious and Parasitic Diseases, University Center of Veterinary Medicine Jagiellonian University—Agriculture Universities, 31-120 Krakow, Poland
| | - Kazimierz Tarasiuk
- Department of Infectious and Parasitic Diseases, University Center of Veterinary Medicine Jagiellonian University—Agriculture Universities, 31-120 Krakow, Poland
| | | | - Yang Wang
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
| | - Jijun He
- State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou 730046, China
- Correspondence: (J.H.); (Y.L.)
| | - Yongsheng Liu
- Hebei Key Laboratory of Preventive Veterinary Medicine, College of Animal Science and Technology, Hebei Normal University of Science & Technology, Qinhuangdao 066004, China
- Correspondence: (J.H.); (Y.L.)
| |
Collapse
|
10
|
Kim JW, Park KW, Kim M, Lee KK, Lee CS. Highly Specific Loop-Mediated Isothermal Amplification Using Graphene Oxide-Gold Nanoparticles Nanocomposite for Foot-and-Mouth Disease Virus Detection. NANOMATERIALS 2022; 12:nano12020264. [PMID: 35055281 PMCID: PMC8778833 DOI: 10.3390/nano12020264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/04/2022] [Accepted: 01/11/2022] [Indexed: 12/10/2022]
Abstract
Loop-mediated isothermal amplification (LAMP) is a molecular diagnosis technology with the advantages of rapid results, isothermal reaction conditions, and high sensitivity. However, this diagnostic system often produces false positive results due to a high rate of non-specific reactions caused by formation of hairpin structures, self-dimers, and mismatched hybridization. The non-specific signals can be due to primers used in the methods because the utilization of multiple LAMP primers increases the possibility of self-annealing of primers or mismatches between primers and templates. In this study, we report a nanomaterial-assisted LAMP method that uses a graphene oxide-gold nanoparticles (AuNPs@GO) nanocomposite to enable the detection of foot-and-mouth disease virus (FMDV) with high sensitivity and specificity. Foot-and-mouth disease (FMD) is a highly contagious and deadly disease in cloven-hoofed animals; hence, a rapid, sensitive, and specific detection method is necessary. The proposed approach exhibited high sensitivity and successful reduction of non-specific signals compared to the traditionally established LAMP assays. Additionally, a mechanism study revealed that these results arose from the adsorption of single-stranded DNA on AuNPs@GO nanocomposite. Thus, AuNPs@GO nanocomposite is demonstrated to be a promising additive in the LAMP system to achieve highly sensitive and specific detection of diverse diseases, including FMD.
Collapse
Affiliation(s)
- Jong-Won Kim
- Bionanotechnology Research Center, Korea Research Institute of Bioscience & Biotechnology (KRIBB), Daejeon 34141, Korea; (J.-W.K.); (K.-W.P.); (M.K.); (K.K.L.)
| | - Kyoung-Woo Park
- Bionanotechnology Research Center, Korea Research Institute of Bioscience & Biotechnology (KRIBB), Daejeon 34141, Korea; (J.-W.K.); (K.-W.P.); (M.K.); (K.K.L.)
- Department of Biotechnology, University of Science & Technology (UST), Daejeon 34113, Korea
| | - Myeongkun Kim
- Bionanotechnology Research Center, Korea Research Institute of Bioscience & Biotechnology (KRIBB), Daejeon 34141, Korea; (J.-W.K.); (K.-W.P.); (M.K.); (K.K.L.)
| | - Kyung Kwan Lee
- Bionanotechnology Research Center, Korea Research Institute of Bioscience & Biotechnology (KRIBB), Daejeon 34141, Korea; (J.-W.K.); (K.-W.P.); (M.K.); (K.K.L.)
- Department of Biomedical and Nanopharmaceutical Science, College of Pharmacy, Kyung Hee University, Seoul 02447, Korea
| | - Chang-Soo Lee
- Bionanotechnology Research Center, Korea Research Institute of Bioscience & Biotechnology (KRIBB), Daejeon 34141, Korea; (J.-W.K.); (K.-W.P.); (M.K.); (K.K.L.)
- Department of Biotechnology, University of Science & Technology (UST), Daejeon 34113, Korea
- Correspondence: ; Tel.: +82-4-2879-8446
| |
Collapse
|