1
|
Choi JW, Park JW, Choi WJ. Effects of hip joint kinematics on the effective pelvis stiffness and hip impact force during simulated sideways falls. J Biomech 2024; 162:111885. [PMID: 38039920 DOI: 10.1016/j.jbiomech.2023.111885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 11/21/2023] [Accepted: 11/23/2023] [Indexed: 12/03/2023]
Abstract
Improved understanding is required on how hip fracture risk is influenced by landing configuration. We examined how hip impact dynamics was affected by hip joint kinematics during simulated sideways falls. Twelve young adults (7 males, 5 females) of mean age 23.5 (SD = 1.5) years, participated in pelvis release experiments. Trials were acquired with the hip flexed 15° and 30° for each of three hip rotations: +15° ("external rotation"), 0°, and -15° ("internal rotation"). During falls, force-deformation data of the pelvis were recorded. Outcome variables included the peak hip impact force (Fexperimental) and effective stiffness of the pelvis (k1st, ksecant, and kms) determined with different methods suggested in literature, and predicted hip impact force during a fall from standing height (F1st, Fsecant and Fms). The two-way repeated-measures ANOVA was used to test whether these variables were associated with hip joint angles. The Fexperimental, ksecant and Fsecant were associated with hip rotation (F = 5.587, p = 0.005; F = 9.278, p < 0.0005; F = 5.778, p = 0.004, respectively), and 15 %, 31 % and 17 % smaller in 15° external than internal rotation (848 versus 998 N; 24.6 versus 35.6 kN/m; 2,637 versus 3,170 N, respectively). However, none of the outcome variables were associated with hip flexion (p > 0.05). Furthermore, there were no interactions between the hip rotation and flexion for all outcome variables (p > 0.05). Our results provide insights on hip impact dynamics, which may help improve a hip model to assess hip fracture risk during a fall.
Collapse
Affiliation(s)
- J W Choi
- Injury Prevention and Biomechanics Laboratory, Department of Physical Therapy, Yonsei University, Wonju, Gangwon-do, South Korea
| | - J W Park
- Injury Prevention and Biomechanics Laboratory, Department of Physical Therapy, Yonsei University, Wonju, Gangwon-do, South Korea
| | - W J Choi
- Injury Prevention and Biomechanics Laboratory, Department of Physical Therapy, Yonsei University, Wonju, Gangwon-do, South Korea.
| |
Collapse
|
2
|
Snow T, Woolley W, Acevedo C, Kingstedt OT. Effect of in vitro ribosylation on the dynamic fracture behavior of mature bovine cortical bone. J Mech Behav Biomed Mater 2023; 148:106171. [PMID: 37890344 DOI: 10.1016/j.jmbbm.2023.106171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 05/01/2023] [Accepted: 10/09/2023] [Indexed: 10/29/2023]
Abstract
In this study, the fracture behavior of ribosylated bovine cortical bone is investigated under loading conditions simulating a fall event. Single edge notched specimens, separated into a control group (n = 11) and a ribosylated group (n = 8), were extracted from the mid-diaphysis of a single bovine femur harvested from a mature cow. A seven-day ribosylation process results in the accumulation of Advanced-Glycation End Products (AGEs) cross-links and AGE adducts. Specimens were subjected to symmetric three point bending (opening mode) and an impact velocity of 1.6 m/s using a drop tower. Near-crack displacement fields up to fracture initiation are determined from high-speed images post-processed using digital image correlation. A constrained over-deterministic least squares regression and orthotropic material linear elastic fracture mechanics theory are used to extract the in-plane critical stress intensity factors at fracture initiation (i.e., fracture initiation toughness values). Statistically significant differences were not observed when comparing the in-plane fracture initiation toughness values (p≥0.96) or energy release rate (p=0.90) between the control and seven-day ribosylated groups. The intrinsic variability of bone may require high sample numbers in order to achieve an adequately powered experiment when assessing dynamic fracture behavior. While there are no detectable differences due to the ribosylation treatment investigated, this is likely due to the limited sample sizes utilized.
Collapse
Affiliation(s)
- Tanner Snow
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, 84112, USA
| | - William Woolley
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, 84112, USA; Department of Mechanical and Aerospace Engineering, University of California San Diego, San Diego, CA, 92093, USA
| | - Claire Acevedo
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, 84112, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, 84112, USA; Department of Mechanical and Aerospace Engineering, University of California San Diego, San Diego, CA, 92093, USA.
| | - Owen T Kingstedt
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, 84112, USA.
| |
Collapse
|
3
|
Omer M, Ngo C, Ali H, Orlovskaya N, Cheong VS, Ballesteros A, Garner MT, Wynn A, Martyniak K, Wei F, Collins BE, Yarmolenko SN, Asiatico J, Kinzel M, Ghosh R, Meckmongkol T, Calder A, Dahir N, Gilbertson TA, Sankar J, Coathup M. The Effect of Omega-9 on Bone Viscoelasticity and Strength in an Ovariectomized Diet-Fed Murine Model. Nutrients 2023; 15:nu15051209. [PMID: 36904208 PMCID: PMC10005705 DOI: 10.3390/nu15051209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 01/30/2023] [Accepted: 02/10/2023] [Indexed: 03/08/2023] Open
Abstract
Few studies have investigated the effect of a monosaturated diet high in ω-9 on osteoporosis. We hypothesized that omega-9 (ω-9) protects ovariectomized (OVX) mice from a decline in bone microarchitecture, tissue loss, and mechanical strength, thereby serving as a modifiable dietary intervention against osteoporotic deterioration. Female C57BL/6J mice were assigned to sham-ovariectomy, ovariectomy, or ovariectomy + estradiol treatment prior to switching their feed to a diet high in ω-9 for 12 weeks. Tibiae were evaluated using DMA, 3-point-bending, histomorphometry, and microCT. A significant decrease in lean mass (p = 0.05), tibial area (p = 0.009), and cross-sectional moment of inertia (p = 0.028) was measured in OVX mice compared to the control. A trend was seen where OVX bone displayed increased elastic modulus, ductility, storage modulus, and loss modulus, suggesting the ω-9 diet paradoxically increased both stiffness and viscosity. This implies beneficial alterations on the macro-structural, and micro-tissue level in OVX bone, potentially decreasing the fracture risk. Supporting this, no significant differences in ultimate, fracture, and yield stresses were measured. A diet high in ω-9 did not prevent microarchitectural deterioration, nevertheless, healthy tibial strength and resistance to fracture was maintained via mechanisms independent of bone structure/shape. Further investigation of ω-9 as a therapeutic in osteoporosis is warranted.
Collapse
Affiliation(s)
- Mahmoud Omer
- Biionix Cluster, University of Central Florida, Orlando, FL 32827, USA
- Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA
| | - Christopher Ngo
- Biionix Cluster, University of Central Florida, Orlando, FL 32827, USA
| | - Hessein Ali
- Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA
| | - Nina Orlovskaya
- Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA
| | - Vee San Cheong
- Insigneo Institute for In Silico Medicine, University of Sheffield, Sheffield S1 3JD, UK
| | | | | | - Austin Wynn
- College of Medicine, University of Central Florida, Orlando, FL 32827, USA
| | - Kari Martyniak
- Biionix Cluster, University of Central Florida, Orlando, FL 32827, USA
| | - Fei Wei
- Biionix Cluster, University of Central Florida, Orlando, FL 32827, USA
| | - Boyce E. Collins
- Engineering Research Center for Revolutionizing Biomaterials, North Carolina A&T State University, Greensboro, NC 27411, USA
| | - Sergey N. Yarmolenko
- Engineering Research Center for Revolutionizing Biomaterials, North Carolina A&T State University, Greensboro, NC 27411, USA
| | - Jackson Asiatico
- Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA
| | - Michael Kinzel
- Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA
| | - Ranajay Ghosh
- Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA
| | - Teerin Meckmongkol
- Biionix Cluster, University of Central Florida, Orlando, FL 32827, USA
- Department of General Surgery, Nemours Children’s Hospital, Orlando, FL 32827, USA
| | - Ashley Calder
- College of Medicine, University of Central Florida, Orlando, FL 32827, USA
| | - Naima Dahir
- College of Medicine, University of Central Florida, Orlando, FL 32827, USA
| | | | - Jagannathan Sankar
- Engineering Research Center for Revolutionizing Biomaterials, North Carolina A&T State University, Greensboro, NC 27411, USA
| | - Melanie Coathup
- Biionix Cluster, University of Central Florida, Orlando, FL 32827, USA
- Correspondence: ; Tel.: +1-407-266-7184
| |
Collapse
|
4
|
Robinovitch SN, Dojnov A, Komisar V, Yang Y, Shishov N, Yu Y, Bercovitz I, Cusimano MD, Becker C, Mackey DC, Chong H. Protective responses of older adults for avoiding injury during falls: evidence from video capture of real-life falls in long-term care. Age Ageing 2022; 51:6881501. [PMID: 36477785 PMCID: PMC9729006 DOI: 10.1093/ageing/afac273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 08/19/2022] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND falls are common in older adults, and any fall from standing height onto a rigid surface has the potential to cause a serious brain injury or bone fracture. Safe strategies for falling in humans have traditionally been difficult to study. OBJECTIVE to determine whether specific 'safe landing' strategies (body rotation during descent, and upper limb bracing) separate injurious and non-injurious falls in seniors. DESIGN observational cohort study. SETTING two long-term care homes in Vancouver BC. METHODS videos of 2,388 falls experienced by 658 participants (mean age 84.0 years; SD 8.1) were analysed with a structured questionnaire. General estimating equations were used to examine how safe landing strategies associated with documented injuries. RESULTS injuries occurred in 38% of falls, and 4% of falls caused injuries treated in hospitals. 32% of injuries were to the head. Rotation during descent was common and protective against injury. In 43% of falls initially directed forward, participants rotated to land sideways, which reduced their odds for head injury 2-fold. Upper limb bracing was used in 58% of falls, but rather than protective, bracing was associated with an increased odds for injury, possibly because it occurred more often in the demanding scenario of forward landings. CONCLUSIONS the risk for injury during falls in long-term care was reduced by rotation during descent, but not by upper limb bracing. Our results expand our understanding of human postural responses to falls, and point towards novel strategies to prevent fall-related injuries.
Collapse
Affiliation(s)
- Stephen N Robinovitch
- Address correspondence to: S. Robinovitch, Injury Prevention and Mobility Laboratory, Room K8508, Simon Fraser University, 8888 University Drive, Burnaby, BC V5A 1S6, Canada.
| | - Aleksandra Dojnov
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada,Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Vicki Komisar
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada,School of Engineering, The University of British Columbia, Kelowna, BC, Canada
| | - Yijian Yang
- Department of Sports Science and Physical Education, The Chinese University of Hong Kong, Hong Kong, China
| | - Nataliya Shishov
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada
| | - Ying Yu
- Department of Statistics and Actuarial Science, Simon Fraser University, Burnaby, BC, Canada
| | - Ian Bercovitz
- Department of Statistics and Actuarial Science, Simon Fraser University, Burnaby, BC, Canada
| | - Michael D Cusimano
- Division of Neurosurgery, Li Ka Shing Knowledge Institute, Injury Prevention Research Office, St. Michael’s Hospital – Unity Health, Toronto, ON, Canada
| | - Clemens Becker
- Robert Bosch Hospital, Stuttgart, Germany,Unit of Digital Geriatric Medicine, University Hospital, Heidelberg, Germany
| | - Dawn C Mackey
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada
| | - Helen Chong
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada
| |
Collapse
|
5
|
The Influence of Static Load and Sideways Impact Fall on Extramedullary Bone Plates Used to Treat Intertrochanteric Femoral Fracture: A Preclinical Strength Assessment. Ann Biomed Eng 2022; 50:1923-1940. [PMID: 35821164 DOI: 10.1007/s10439-022-03013-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 07/06/2022] [Indexed: 12/30/2022]
Abstract
Hip fracture accounts for a large number of hospitalizations, thereby causing substantial economic burden. Majority (> 90%) of all hip fractures are associated to sideways fall. Studies on sideways fall usually involve loading at quasi-static or at constant displacement rate, which neglects the physics of actual fall. Understanding femur resonance frequency and associated mode shapes excited by dynamic loads is also critical. Two commercial extramedullary implants, proximal femoral locking plate (PFLP) and variable angle dynamic hip screw (VA-DHS), were chosen to carry out the preclinical assessments on a simulated Evans-I type intertrochanteric fracture. In this study, we hypothesized that the behavior of the implant depends on the loading types-axial static and transverse impact-and a rigid implanted construct will absorb less impact energy for sideways fall. The in silico models were validated using experimental measurements of full-field strain data obtained from a 2D digital image correlation (DIC) study. Under peak axial load of 3 kN, PFLP construct predicted greater axial stiffness (1.07 kN/mm) as opposed to VA-DHS (0.85 kN/mm), although the former predicted slightly higher proximal stress shielding. Further, with greater mode 2 frequency, PFLP predicted improved performance in resisting bending due to sideways fall as compared to the other implant. Overall, the PFLP implanted femur predicted the least propensity to adverse stress intensities, suggesting better structural rigidity and higher capacity in protecting the fractured femur against fall.
Collapse
|
6
|
Effect of Body Mass Index on Femur Fracture Location: A Retrospective Database Study. J Orthop Trauma 2022; 36:519-524. [PMID: 35452051 DOI: 10.1097/bot.0000000000002378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/14/2022] [Indexed: 02/02/2023]
Abstract
OBJECTIVES Use a large database design and multivariable analyses to assess the associations between body mass index (BMI) and femur fracture patterns after controlling for other risk factors. DESIGN Retrospective cohort study. SETTING National insurance claims database of patient records from 2010 to 2018. PATIENTS/PARTICIPANTS Patients with femur fracture diagnoses were identified. Patients with multiple fractures within 1 week (polytrauma patients), patients without a BMI diagnosis code within 6 months of fracture, and patients with multiple BMI diagnosis codes (implying a substantial change in weight) were excluded. INTERVENTION N/A. MAIN OUTCOME MEASUREMENTS Patients were divided into groups based on fracture location: proximal (OTA/AO 31), shaft (OTA/AO 32), or distal (OTA/AO 33). The distribution of femur fractures was compared across BMI categories. RESULTS A total of 57,042 patients with femur fracture were identified: 45,586 proximal fractures, 4216 shaft fractures, and 7240 distal fractures. Patients with BMI <29.9 have increased odds ( P < 0.0001) of proximal fracture and decreased odds ( P < 0.0001) of shaft or distal fractures. Patients with BMI >30.0 have decreased odds ( P < 0.0001) of proximal fracture and increased odds ( P < 0.0001) of distal fractures. CONCLUSIONS Increasing BMI is associated with a decreased proportion of proximal femur fractures and a corresponding increase in the proportion of shaft and distal fractures. Regression analyses determined that age, sex, osteoporosis, diabetes, and tobacco use are not the cause of this trend. LEVEL OF EVIDENCE Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
7
|
Galliker ES, Laing AC, Ferguson SJ, Helgason B, Fleps I. The Influence of Fall Direction and Hip Protector on Fracture Risk: FE Model Predictions Driven by Experimental Data. Ann Biomed Eng 2022; 50:278-290. [PMID: 35129719 PMCID: PMC8847295 DOI: 10.1007/s10439-022-02917-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Accepted: 01/02/2022] [Indexed: 11/25/2022]
Abstract
Hip fractures in older adults, which often lead to lasting impairments and an increased risk of mortality, are a major public health concern. Hip fracture risk is multi-factorial, affected by the risk of falling, the load acting on the femur, and the load the femur can withstand. This study investigates the influence of impact direction on hip fracture risk and hip protector efficacy. We simulated falls for 4 subjects, in 7 different impact directions (15° and 30° anterior, lateral, and 15°, 30°, 60°, and 90° posterior) at two different impact velocities (2.1 and 3.1 m/s), all with and without hip protector, using previously validated biofidelic finite element models. We found the highest number of fractures and highest fragility ratios in lateral and 15° posterior impacts. The hip protector attenuated femur forces by 23–49 % for slim subjects under impact directions that resulted in fractures (30° anterior to 30° posterior). The hip protector prevented all fractures (6/6) for 2.1 m/s impacts, but only 10% of fractures for 3.1 m/s impacts. Our results provide evidence that, regarding hip fracture risk, posterior-lateral impacts are as dangerous as lateral impacts, and they support the efficacy of soft-shell hip protectors for anterior- and posterior-lateral impacts.
Collapse
Affiliation(s)
| | - Andrew C Laing
- Department of Kinesiology and Health Sciences, University of Waterloo, Waterloo, Canada
| | | | | | - Ingmar Fleps
- Institute for Biomechanics, ETH-Zurich, Zurich, Switzerland.
| |
Collapse
|
8
|
Aldieri A, Terzini M, Audenino AL, Bignardi C, Paggiosi M, Eastell R, Viceconti M, Bhattacharya P. Personalised 3D Assessment of Trochanteric Soft Tissues Improves HIP Fracture Classification Accuracy. Ann Biomed Eng 2022; 50:303-313. [PMID: 35103867 PMCID: PMC8847196 DOI: 10.1007/s10439-022-02924-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Accepted: 01/19/2022] [Indexed: 01/09/2023]
Abstract
Passive soft tissues surrounding the trochanteric region attenuate fall impact forces and thereby control hip fracture risk. The degree of attenuation is related to Soft Tissue Thickness (STT). STT at the neutral hip impact orientation, estimated using a regression relation in body mass index (BMI), was previously shown to influence the current absolute risk of hip fracture (ARF0) and its fracture classification accuracy. The present study investigates whether fracture classification using ARF0 improves when STT is determined from the subject’s Computed-Tomography (CT) scans (i.e. personalised) in an orientation-specific (i.e. 3D) manner. STT is calculated as the shortest distance along any impact orientation between a semi-automatically segmented femur surface and an automatically segmented soft tissue/air boundary. For any subject, STT along any of the 33 impact orientations analysed always exceeds the value estimated using BMI. Accuracy of fracture classification using ARF0 improves when using personalised 3D STT estimates (AUC = 0.87) instead of the BMI-based STT estimate (AUC = 0.85). The improvement is smaller (AUC = 0.86) when orientation-specificity of CT-based STT is suppressed and is nil when personalisation is suppressed instead. Thus, fracture classification using ARF0 improves when CT is used to personalise STT estimates and improves further when, in addition, the estimates are orientation specific.
Collapse
Affiliation(s)
- Alessandra Aldieri
- PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy.,Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Mara Terzini
- PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Alberto L Audenino
- PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Cristina Bignardi
- PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Margaret Paggiosi
- INSIGNEO Institute for In Silico Medicine, University of Sheffield, Pam Liversidge Building, Sheffield, S1 3JD, UK.,Academic Unit of Bone Metabolism, University of Sheffield, Sheffield, UK
| | - Richard Eastell
- INSIGNEO Institute for In Silico Medicine, University of Sheffield, Pam Liversidge Building, Sheffield, S1 3JD, UK.,Academic Unit of Bone Metabolism, University of Sheffield, Sheffield, UK
| | - Marco Viceconti
- Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy.,Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Pinaki Bhattacharya
- INSIGNEO Institute for In Silico Medicine, University of Sheffield, Pam Liversidge Building, Sheffield, S1 3JD, UK. .,Department of Mechanical Engineering, University of Sheffield, Sheffield, UK.
| |
Collapse
|
9
|
Spartacus V, Shojaeizadeh M, Raffault V, Shoults J, Van Wieren K, Sparrey CJ. In vivo soft tissue compressive properties of the human hand. PLoS One 2021; 16:e0261008. [PMID: 34898632 PMCID: PMC8668133 DOI: 10.1371/journal.pone.0261008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 11/22/2021] [Indexed: 12/25/2022] Open
Abstract
Background/Purpose Falls onto outstretched hands are the second most common sports injury and one of the leading causes of upper extremity injury. Injury risk and severity depends on forces being transmitted through the palmar surface to the upper extremity. Although the magnitude and distribution of forces depend on the soft tissue response of the palm, the in vivo properties of palmar tissue have not been characterized. The purpose of this study was to characterize the large deformation palmar soft tissue properties. Methods In vivo dynamic indentations were conducted on 15 young adults (21–29 years) to quantify the soft tissue characteristics of over the trapezium. The effects of loading rate, joint position, tissue thickness and sex on soft tissue responses were assessed. Results Energy absorbed by the soft tissue and peak force were affected by loading rate and joint angle. Energy absorbed was 1.7–2.8 times higher and the peak force was 2–2.75 times higher at high rate loading than quasistatic rates. Males had greater energy absorbed than females but not at all wrist positions. Damping characteristics were the highest in the group with the thickest soft tissue while damping characteristics were the lowest in group with the thinnest soft tissues. Conclusion Palmar tissue response changes with joint position, loading rate, sex, and tissue thickness. Accurately capturing these tissue responses is important for developing effective simulations of fall and injury biomechanics and assessing the effectiveness of injury prevention strategies.
Collapse
Affiliation(s)
- Victoria Spartacus
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
- * E-mail:
| | - Maedeh Shojaeizadeh
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
| | - Vincent Raffault
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
| | - James Shoults
- Science Technical Center, Simon Fraser University, Burnaby, BC, Canada
| | - Ken Van Wieren
- Science Technical Center, Simon Fraser University, Burnaby, BC, Canada
| | - Carolyn J. Sparrey
- Mechatronic Systems Engineering, Simon Fraser University, Surrey, British Columbia, Canada
- International Collaboration on Repair Discoveries (ICORD), Vancouver, British Columbia, Canada
| |
Collapse
|
10
|
The Effects of Body Position on Trochanteric Soft Tissue Thickness-Implications for Predictions of Impact Force and Hip Fracture Risk During Lateral Falls. J Appl Biomech 2021; 37:556-564. [PMID: 34784585 DOI: 10.1123/jab.2020-0156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 01/28/2021] [Accepted: 09/16/2021] [Indexed: 11/18/2022]
Abstract
Trochanteric soft tissue thickness (TSTT) is a protective factor against fall-related hip fractures. This study's objectives were to determine: (1) the influence of body posture on TSTT and (2) the downstream effects of TSTT on biomechanical model predictions of fall-related impact force (Ffemur) and hip fracture factor of risk. Ultrasound was used to measure TSTT in 45 community-dwelling older adults in standing, supine, and side-lying positions with hip rotation angles of -25°, 0°, and 25°. Supine TSTT (mean [SD] = 5.57 [2.8] cm) was 29% and 69% greater than in standing and side-lying positions, respectively. The Ffemur based on supine TSTT (3380 [2017] N) was 19% lower than the standing position (4173 [1764] N) and 31% lower than the side-lying position (4908 [1524] N). As factor of risk was directly influenced by Ffemur, the relative effects on fracture risk were similar. While less pronounced (<10%), the effects of hip rotation angle were consistent across TSTT, Ffemur, and factor of risk. Based on the sensitivity of impact models to TSTT, these results highlight the need for a standardized TSTT measurement approach. In addition, the consistent influence of hip rotation on TSTT (and downstream model predictions) support its importance as a factor that may influence fall-related hip fracture risk.
Collapse
|
11
|
Shishov N, Elabd K, Komisar V, Chong H, Robinovitch SN. Accuracy of Kinovea software in estimating body segment movements during falls captured on standard video: Effects of fall direction, camera perspective and video calibration technique. PLoS One 2021; 16:e0258923. [PMID: 34695159 PMCID: PMC8544843 DOI: 10.1371/journal.pone.0258923] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 10/11/2021] [Indexed: 11/18/2022] Open
Abstract
Falls are a major cause of unintentional injuries. Understanding the movements of the body during falls is important to the design of fall prevention and management strategies, including exercise programs, mobility aids, fall detectors, protective gear, and safer environments. Video footage of real-life falls is increasingly available, and may be used with digitization software to extract kinematic features of falls. We examined the validity of this approach by conducting laboratory falling experiments, and comparing linear and angular positions and velocities measured from 3D motion capture to estimates from Kinovea 2D digitization software based on standard surveillance video (30 Hz, 640x480 pixels). We also examined how Kinovea accuracy depended on fall direction, camera angle, filtering cut-off frequency, and calibration technique. For a camera oriented perpendicular to the plane of the fall (90 degrees), Kinovea position data filtered at 10 Hz, and video calibration using a 2D grid, mean root mean square errors were 0.050 m or 9% of the signal amplitude and 0.22 m/s (7%) for vertical position and velocity, and 0.035 m (6%) and 0.16 m/s (7%) for horizontal position and velocity. Errors in angular measures averaged over 2-fold higher in sideways than forward or backward falls, due to out-of-plane movement of the knees and elbows. Errors in horizontal velocity were 2.5-fold higher for a 30 than 90 degree camera angle, and 1.6-fold higher for calibration using participants’ height (1D) instead of a 2D grid. When compared to 10 Hz, filtering at 3 Hz caused velocity errors to increase 1.4-fold. Our results demonstrate that Kinovea can be applied to 30 Hz video to measure linear positions and velocities to within 9% accuracy. Lower accuracy was observed for angular kinematics of the upper and lower limb in sideways falls, and for horizontal measures from 30 degree cameras or 1D height-based calibration.
Collapse
Affiliation(s)
- Nataliya Shishov
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, British Columbia, Canada
- * E-mail:
| | - Karam Elabd
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, Canada
| | - Vicki Komisar
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, British Columbia, Canada
- School of Engineering, The University of British Columbia, Kelowna, British Columbia, Canada
| | - Helen Chong
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, British Columbia, Canada
| | - Stephen N. Robinovitch
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, British Columbia, Canada
- School of Engineering Science, Simon Fraser University, Burnaby, British Columbia, Canada
| |
Collapse
|
12
|
Sahandifar P, Kleiven S. Influence of nonlinear soft tissue modeling on the external and internal forces during lateral hip impacts. J Mech Behav Biomed Mater 2021; 124:104743. [PMID: 34474319 DOI: 10.1016/j.jmbbm.2021.104743] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 07/27/2021] [Accepted: 07/28/2021] [Indexed: 11/16/2022]
Abstract
Soft tissues in the hip region, which are typically considered the natural shock-absorbers during falls, attenuate the applied forces to the underlying hard tissue. The soft tissue thickness is, therefore, a significant parameter in the force attenuation. Another factor that could affect the assessment of the force attenuation in numerical simulations is the choice of constitutive model and material parameters for the soft tissue. Several constitutive models and parameters for muscle and adipose tissue were suggested in the published literature; however, the biofidelity of the proposed models for the lateral impacts has not been assessed yet. To achieve this purpose, we used a previously developed human body model named THUMS v4.02 and modified the mechanical properties and geometry of the soft tissues in the hip region. The simulations consisted of regional hip models and whole-body models. The biofidelity of the constitutive models of muscle and adipose tissue was determined objectively using the CORrelation and Analysis (CORA) rating. Moreover, the potential force attenuating effect of the adipose tissue thickness was investigated in the regional models. We collected and fitted several available nonlinear material models for muscle and adipose tissue and implemented them. The CORA ratings for several constitutive models for adipose tissue in the regional model were above 0.8. Among the muscle constitutive models, three Ogden models consistently rated above 0.58 for the whole-body model. Moreover, the impact forces in the selected adipose tissue model attenuated 47 N for every 1 mm increase in thickness. Overall, the choice of the nonlinear material model for the adipose and muscle tissue influences the external and internal force, and the difference between the material models is more pronounced when the thickness of the soft tissue increases.
Collapse
Affiliation(s)
- Pooya Sahandifar
- Neuronic Engineering, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Svein Kleiven
- Neuronic Engineering, KTH Royal Institute of Technology, Stockholm, Sweden
| |
Collapse
|
13
|
Aguiar OMG, Radivojevic O, Potvin BM, Vakili O, Robinovitch SN. Effective stiffness, damping and mass of the body during laboratory simulations of shoulder checks in ice hockey. Sports Biomech 2021:1-12. [PMID: 34319214 DOI: 10.1080/14763141.2021.1951828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 06/30/2021] [Indexed: 10/20/2022]
Abstract
Ice hockey is a fast-paced sport with a high incidence of collisions between players. Shoulder checks are especially common, accounting for a large portion of injuries including concussions. The forces generated during these collisions depend on the inertial and viscoelastic characteristics of the impacting bodies. Furthermore, the effect of shoulder pads in reducing peak force depends on the baseline (unpadded) properties of the shoulder. We conducted experiments with nine men's ice hockey players (aged 19-26) to measure their effective shoulder stiffness, damping and mass during the impact stage of a shoulder check. Participants delivered a style of check commonly observed in men's university ice hockey, involving lateral impact to the deltoid region, with the shoulder brought stationary by the collision. The effective stiffness and damping coefficient of the shoulder averaged 12.8 kN/m and 377 N-s/m at 550 N, and the effective mass averaged 47% of total body mass. The damping coefficient and stiffness increased with increasing force, but there was no significant difference in the damping coefficient above 350 N. Our results provide new evidence on the dynamics of shoulder checks in ice hockey, as a starting point for designing test systems for evaluating and improving the protective value of shoulder pads.
Collapse
Affiliation(s)
- Olivia M G Aguiar
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada
| | - Olga Radivojevic
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada
| | - Brigitte M Potvin
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada
| | - Omid Vakili
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada
| | - Stephen N Robinovitch
- Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC, Canada
| |
Collapse
|
14
|
Gao K, Li C, Xiao Y, Zhang Z. Finite element modeling and parameter identification of the seated human body exposed to vertical vibration. Biomech Model Mechanobiol 2021; 20:1789-1803. [PMID: 34268622 DOI: 10.1007/s10237-021-01481-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 06/04/2021] [Indexed: 11/24/2022]
Abstract
Developing a biomechanical model which connected with the actual anatomy of the human body is helpful to understand the human response to vibration. A finite element model of the seated human body with 175 cm in stature and 68.6 kg in weight, which consists of seven segments, six joints and soft tissue, was established to reflect apparent mass based on the Hybrid III dummy model. By comparing the body segment mass percentages with previous data, the rationality of mass distribution in this model was verified. The biomechanical parameters play a crucial role in biodynamic modeling, while the joint and soft tissue parameters are difficult to choose due to the wide range of anthropometric parameters. In this study, the root-mean-square error between the calculated and the measured apparent mass was taken as objective function, and the effect of fifteen human parameters on the objective function was analyzed through sensitivity analysis. Then seven parameters with a considerable influence on the objective function were selected as design variables, and four approximate models were established for parameter optimization. Soft tissues and joint parameters of the model were determined by parameter identification, and the finite element model that can reflect vertical in-line and fore-and-aft cross-axis apparent mass of the human body without backrest was developed. The seated human model presented in this paper can also reflect the transmissibility from seat to the first thoracic spine and the main modes of the human body below 10 Hz, which is conducive to express the human response to vibration.
Collapse
Affiliation(s)
- Kaizhan Gao
- School of Automotive Engineering, Chongqing University, Chongqing, 400030, China
| | - Chunyu Li
- School of Automotive Engineering, Chongqing University, Chongqing, 400030, China
| | - Yang Xiao
- School of Automotive Engineering, Chongqing University, Chongqing, 400030, China
| | - Zhifei Zhang
- School of Automotive Engineering, Chongqing University, Chongqing, 400030, China.
| |
Collapse
|
15
|
Luo Y. On challenges in clinical assessment of hip fracture risk using image-based biomechanical modelling: a critical review. J Bone Miner Metab 2021; 39:523-533. [PMID: 33423096 DOI: 10.1007/s00774-020-01198-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 12/11/2020] [Indexed: 10/22/2022]
Abstract
INTRODUCTION Hip fracture is a common health risk among elderly people, due to the prevalence of osteoporosis and accidental fall in the population. Accurate assessment of fracture risk is a crucial step for clinicians to consider patient-by-patient optimal treatments for effective prevention of fractures. Image-based biomechanical modeling has shown promising progress in assessment of fracture risk, and there is still a great possibility for improvement. The purpose of this paper is to identify key issues that need be addressed to improve image-based biomechanical modeling. MATERIALS AND METHODS We critically examined issues in consideration and determination of the four biomechanical variables, i.e., risk of fall, fall-induced impact force, bone geometry and bone material quality, which are essential for prediction of hip fracture risk. We closely inspected: limitations introduced by assumptions that are adopted in existing models; deficiencies in methods for construction of biomechanical models, especially for determination of bone material properties from bone images; problems caused by separate use of the variables in clinical study of hip fracture risk; availability of clinical information that are required for validation of biomechanical models. RESULTS AND CONCLUSIONS A number of critical issues and gaps were identified. Strategies for effectively addressing the issues were discussed.
Collapse
Affiliation(s)
- Yunhua Luo
- Department of Mechanical Engineering, University of Manitoba, 75A Chancellor's Circle, Winnipeg, MB, R3T 2N2, Canada.
- Department of Biomedical Engineering, University of Manitoba, 75A Chancellor's Circle, Winnipeg, MB, R3T 2N2, Canada.
| |
Collapse
|
16
|
Milazzo M, David A, Jung GS, Danti S, Buehler MJ. Molecular origin of viscoelasticity in mineralized collagen fibrils. Biomater Sci 2021; 9:3390-3400. [PMID: 33949363 PMCID: PMC8323817 DOI: 10.1039/d0bm02003f] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 03/01/2021] [Indexed: 11/21/2022]
Abstract
Bone is mineralized tissue constituting the skeletal system, supporting and protecting the body's organs and tissues. In addition to such fundamental mechanical functions, bone also plays a remarkable role in sound conduction. From a mechanical standpoint, bone is a composite material consisting of minerals and collagen arranged in multiple hierarchical structures, with a complex anisotropic viscoelastic response, capable of transmitting and dissipating energy. At the molecular level, mineralized collagen fibrils are the basic building blocks of bone tissue, and hence, understanding bone properties down to fundamental tissue structures enables better identification of the mechanisms of structural failures and damage. While efforts have focused on the study of micro- and macro-scale viscoelasticity related to bone damage and healing based on creep, mineralized collagen has not been explored at the molecular level. We report a study that aims at systematically exploring the viscoelasticity of collagenous fibrils with different mineralization levels. We investigate the dynamic mechanical response upon cyclic and impulsive loads to observe the viscoelastic phenomena from either shear or extensional strains via molecular dynamics. We perform a sensitivity analysis with several key benchmarks: intrafibrillar mineralization percentage, hydration state, and external load amplitude. Our results show an increase of the dynamic moduli with an increase of the mineral percentage, pronounced at low strains. When intrafibrillar water is present, the material softens the elastic component, but considerably increases its viscosity, especially at high frequencies. This behavior is confirmed from the material response upon impulsive loads, in which water drastically reduces the relaxation times throughout the input velocity range by one order of magnitude, with respect to the dehydrated counterparts. We find that, upon transient loads, water has a major impact on the mechanics of mineralized fibrillar collagen, being able to improve the capability of the tissue to passively and effectively dissipate energy, especially after fast and high-amplitude external loads. Our study provides knowledge of bone mechanics in relation to pathologies deriving from dehydration or traumas. Moreover, these findings show the potential for being used in designing new bioinspired materials not limited to tissue engineering applications, in which passive mechanisms for dissipating energy can prevent structural failures.
Collapse
Affiliation(s)
- Mario Milazzo
- Laboratory for Atomistic and Molecular Mechanics (LAMM), USA. and The BioRobotics Institute, Scuola Superiore Sant'Anna, Italy
| | - Alessio David
- Dipartimento di Chimica, Materiali e Ingegneria Chimica "G. Natta", Politecnico di Milano, Milano, Italy
| | - Gang Seob Jung
- Laboratory for Atomistic and Molecular Mechanics (LAMM), USA. and Computational Sciences and Engineering Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA
| | - Serena Danti
- Laboratory for Atomistic and Molecular Mechanics (LAMM), USA. and The BioRobotics Institute, Scuola Superiore Sant'Anna, Italy and Department of Civil and Industrial Engineering, University of Pisa, Italy
| | | |
Collapse
|
17
|
Lim KT, Choi WJ. The effect of the hip impact configuration on the energy absorption provided by the femoral soft tissue during sideways falls. J Biomech 2021; 117:110254. [PMID: 33493711 DOI: 10.1016/j.jbiomech.2021.110254] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 12/12/2020] [Accepted: 01/10/2021] [Indexed: 12/26/2022]
Abstract
The femoral soft tissue (i.e., skin, muscle, fat) may play a key role in preventing hip fractures during a fall by absorbing the impact energy. We measured the femoral soft tissue deformation and associated compressive force during simulated sideways falls to estimate the energy absorbed by the soft tissue, and then examined how this was affected by the hip impact configuration and gender. Eighteen young adults (9 males and 9 females) participated in the pelvis release experiment. The pelvis was raised through a rope attached to an electromagnet on the ceiling, so the skin surface barely touches the ultrasound probe, which flush to a Plexiglas plate placed on a force plate. The electromagnet was turned off to cause a fall while the soft tissue deformation and associated compressive force were being recorded. Trials were acquired with three hip impact configurations. An outcome variable included the energy absorbed by the femoral soft tissue during a fall. The energy absorbed by the femoral soft tissue ranged from 0.03 to 3.05 J. Furthermore, the energy absorption was associated with the hip impact configuration (F = 4.69, p = 0.016). On average, the absorbed energy was 62% greater in posteriolateral than anteriolateral impact (0.92 versus 0.57 J). However, the energy absorption did not differ between male and female (F = 0.91, p = 0.36). The force-deflection behavior of the femoral soft tissue during a fall has been recorded, providing insights on the potential protective benefits of the soft tissue covering during a fall.
Collapse
Affiliation(s)
- Ki Taek Lim
- Injury Prevention and Biomechanics Laboratory, Department of Physical Therapy, Yonsei University, Wonju, South Korea
| | - Woochol Joseph Choi
- Injury Prevention and Biomechanics Laboratory, Department of Physical Therapy, Yonsei University, Wonju, South Korea.
| |
Collapse
|
18
|
Palanca M, Perilli E, Martelli S. Body Anthropometry and Bone Strength Conjointly Determine the Risk of Hip Fracture in a Sideways Fall. Ann Biomed Eng 2020; 49:1380-1390. [PMID: 33184710 PMCID: PMC8058010 DOI: 10.1007/s10439-020-02682-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Accepted: 10/26/2020] [Indexed: 01/03/2023]
Abstract
We hypothesize that variations of body anthropometry, conjointly with the bone strength, determine the risk of hip fracture. To test the hypothesis, we compared, in a simulated sideways fall, the hip impact energy to the energy needed to fracture the femur. Ten femurs from elderly donors were tested using a novel drop-tower protocol for replicating the hip fracture dynamics during a fall on the side. The impact energy was varied for each femur according to the donor’s body weight, height and soft-tissue thickness, by adjusting the drop height and mass. The fracture pattern, force, energy, strain in the superior femoral neck, bone morphology and microarchitecture were evaluated. Fracture patterns were consistent with clinically relevant hip fractures, and the superior neck strains and timings were comparable with the literature. The hip impact energy (11 – 95 J) and the fracture energy (11 – 39 J) ranges overlapped and showed comparable variance (CV = 69 and 61%, respectively). The aBMD-based definition of osteoporosis correctly classified 7 (70%) fracture/non-fracture cases. The incorrectly classified cases presented large impact energy variations, morphology variations and large subcortical voids as seen in microcomputed tomography. In conclusion, the risk of osteoporotic hip fracture in a sideways fall depends on both body anthropometry and bone strength.
Collapse
Affiliation(s)
- Marco Palanca
- Department of Industrial Engineering, School of Engineering and Architecture, Alma Mater Studiorum - Università di Bologna, Bologna, Italy.
- Department of Oncology and Metabolism, and INSIGNEO Institute for in silico Medicine, University of Sheffield, Sheffield, UK.
| | - Egon Perilli
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, Australia
| | - Saulo Martelli
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, Australia
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
19
|
Villamor E, Monserrat C, Del Río L, Romero-Martín JA, Rupérez MJ. Prediction of osteoporotic hip fracture in postmenopausal women through patient-specific FE analyses and machine learning. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 193:105484. [PMID: 32278980 DOI: 10.1016/j.cmpb.2020.105484] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 03/23/2020] [Accepted: 03/28/2020] [Indexed: 06/11/2023]
Abstract
A great challenge in osteoporosis clinical assessment is identifying patients at higher risk of hip fracture. Bone Mineral Density (BMD) measured by Dual-Energy X-Ray Absorptiometry (DXA) is the current gold-standard, but its classification accuracy is limited to 65%. DXA-based Finite Element (FE) models have been developed to predict the mechanical failure of the bone. Yet, their contribution has been modest. In this study, supervised machine learning (ML) is applied in conjunction with clinical and computationally driven mechanical attributes. Through this multi-technique approach, we aimed to obtain a predictive model that outperforms BMD and other clinical data alone, as well as to identify the best-learned ML classifier within a group of suitable algorithms. A total number of 137 postmenopausal women (81.4 ± 6.95 years) were included in the study and separated into a fracture group (n = 89) and a control group (n = 48). A semi-automatic and patient-specific DXA-based FE model was used to generate mechanical attributes, describing the geometry, the impact force, bone structure and mechanical response of the bone after a sideways-fall. After preprocessing the whole dataset, 19 attributes were selected as predictors. Support Vector Machine (SVM) with radial basis function (RBF), Logistic Regression, Shallow Neural Networks and Random Forest were tested through a comprehensive validation procedure to compare their predictive performance. Clinical attributes were used alone in another experimental setup for the sake of comparison. SVM was confirmed to generate the best-learned algorithm for both experimental setups, including 19 attributes and only clinical attributes. The first, generated the best-learned model and outperformed BMD by 14pp. The results suggests that this approach could be easily integrated for effective prediction of hip fracture without interrupting the actual clinical workflow.
Collapse
Affiliation(s)
- E Villamor
- Valencian Research Institute for Artificial Intelligence (VRAIN), Universitat Politècnica de València, Camino de Vera s/n, Valencia 46022, Spain
| | - C Monserrat
- Valencian Research Institute for Artificial Intelligence (VRAIN), Universitat Politècnica de València, Camino de Vera s/n, Valencia 46022, Spain
| | - L Del Río
- ASCIRES Grupo Biomédico, Valencia, Spain
| | | | - M J Rupérez
- Centro de Investigación en Ingeniería Mecánica, Universitat Politècnica de València, Camino de Vera s/n, Valencia 46022, Spain.
| |
Collapse
|
20
|
Cho Y, Lee I, Ha SH, Park JH, Park JH. Comparison of hip subregion bone mineral density to the type of proximal femur fracture. Arch Osteoporos 2020; 15:122. [PMID: 32757078 DOI: 10.1007/s11657-020-00789-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 07/10/2020] [Indexed: 02/03/2023]
Abstract
UNLABELLED Beta values of the intertrochanteric fracture group were about twice as high as those of the femoral neck fracture group. These results can be used to increase the awareness of proximal hip fracture among physicians and improve treatments and outcomes. PURPOSE To compare the BMD of the femoral neck region and the intertrochanteric region between the femoral neck fracture group and the intertrochanteric fracture group. METHODS We did a retrospective review of radiographs of the proximal femoral fractures in patients registered from 2010 to 2017. A total of 329 patients were classified into the femoral neck fracture group (group A, n = 162) and the femur intertrochanteric fracture group (group B, n = 167). We did intergroup comparisons of age, sex, BMI (body mass index), and bone mineral density (BMD) of the neck and intertrochanteric region, adjusting for age. We did multiple logistic regression analysis among these parameters. RESULTS The BMD of the femoral neck and intertrochanteric was statistically significantly different between the two groups (p < 0.001), and the BMD of the femur intertrochanteric was also significantly different between the two groups (p < 0.001). BMD of both regions in the intertrochanteric fracture group was lower than that of the femoral neck fracture group. In linear regression analysis, the beta values of the intertrochanteric fracture group were about twice as high as those of the femoral neck fracture group. CONCLUSION In linear regression analysis, the beta values of the intertrochanteric fracture group were about twice as high as those of the femoral neck fracture group.
Collapse
Affiliation(s)
- Yongun Cho
- Department of Orthopaedic Surgery, College of Medicine, Konkuk University Chungju Hospital, Konkuk University, Chungju, Republic of Korea
| | - Ingyu Lee
- Department of Orthopaedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-ro, Jongno-gu, Seoul, 03181, Republic of Korea
| | - Sang Hoon Ha
- Department of Orthopaedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-ro, Jongno-gu, Seoul, 03181, Republic of Korea
| | - Jin Hun Park
- Department of Orthopaedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-ro, Jongno-gu, Seoul, 03181, Republic of Korea
| | - Jai Hyung Park
- Department of Orthopaedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-ro, Jongno-gu, Seoul, 03181, Republic of Korea.
| |
Collapse
|
21
|
Martel DR, Lysy M, Laing AC. Predicting population level hip fracture risk: a novel hierarchical model incorporating probabilistic approaches and factor of risk principles. Comput Methods Biomech Biomed Engin 2020; 23:1201-1214. [PMID: 32687412 DOI: 10.1080/10255842.2020.1793331] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Fall-related hip fractures are a major public health issue. While individual-level risk assessment tools exist, population-level predictive models could catalyze innovation in large-scale interventions. This study presents a hierarchical probabilistic model that predicts population-level hip fracture risk based on Factor of Risk (FOR) principles. Model validation demonstrated that FOR output aligned with a published dataset categorized by sex and hip fracture status. The model predicted normalized FOR for 100000 individuals simulating the Canadian older-adult population. Predicted hip fracture risk was higher for females (by an average of 38%), and increased with age (by15% per decade). Potential applications are discussed.
Collapse
Affiliation(s)
- Daniel R Martel
- Department of Kinesiology, University of Waterloo, Waterloo, Ontario, Canada
| | - Martin Lysy
- Department of Statistics and Actuarial Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Andrew C Laing
- Department of Kinesiology, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
22
|
Terzini M, Aldieri A, Nurisso S, De Nisco G, Bignardi C. Finite Element Modeling Application in Forensic Practice: A Periprosthetic Femoral Fracture Case Study. Front Bioeng Biotechnol 2020; 8:619. [PMID: 32656199 PMCID: PMC7324477 DOI: 10.3389/fbioe.2020.00619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 05/20/2020] [Indexed: 11/13/2022] Open
Abstract
The incidence of periprosthetic fractures has rapidly increased in the last two decades and has been the cause of a large number of revision surgeries and permanent physical disability for many patients, as well as a significant socioeconomic burden for many nations. This research deals with a periprosthetic femur fracture real event, occurred following a total hip arthroplasty and treated with one of the most widespread internal fixation methods: the implant of a periprosthetic femur plate system. A Finite Element analysis was performed to investigate the implanted femur plate break after a short follow-up and to understand the plate break causes. Such events are currently object of forensic debate as more and more often hospitals, surgeons, and medical device manufacturers are denounced by patients to whom similar events occur. In this work, different load situations acting on the femur during daily and incidental activities were simulated, in order to validate the correct behavior of the plate, according to the intended use recommended by the manufacturer. The analysis demonstrates that the plate failure can occur in situations of unconventional loading such as that caused by stumbling and in presence of incomplete bone healing.
Collapse
Affiliation(s)
- Mara Terzini
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| | - Alessandra Aldieri
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| | - Stefania Nurisso
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| | - Giuseppe De Nisco
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| | - Cristina Bignardi
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.,PolitoBIOMed Lab, Politecnico di Torino, Turin, Italy
| |
Collapse
|
23
|
Kuo C, Shishov N, Elabd K, Komisar V, Chong H, Phu T, Anderson L, Hoshizaki B, Laing A, Cripton P, Robinovitch S. Estimating Trunk and Neck Stabilization for Avoiding Head Impact during Real-World Falls in Older Adults. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:4823-4826. [PMID: 33019070 DOI: 10.1109/embc44109.2020.9176257] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
In this work, we quantify the neck's involvement in stabilizing the head during falls in older adults to avoid head impacts. We tracked kinematics of 12 real-world backward falls in long-term care captured on video, where head impact was avoided. We estimated dynamic spring-dashpot parameters of the neck and hip representing active muscle activity and passive tissue structures. Neck stiffness, damping, and target posture averaged 24.00±6.17Nm/rad, 0.38±0.16Nms/rad, and 76.2±14.7° flexion respectively. The stiffness and target posture suggest that residents actively contracted their neck muscles to maintain the head upright. Our results shed light on the importance of neck strength for avoiding head impact during a fall.Clinical Relevance-Falls account for 80% of traumatic brain injuries in adults 65+ years. While upper limb bracing can reduce the risk of head impacts during a fall in young adults, this protective response is less effective in older adults living in longterm care. Understanding how the neck and torso musculature are used to avoid head impact can guide the design of therapeutic exercise programs and assistive or protective devices.
Collapse
|
24
|
Fleps I, Guy P, Ferguson SJ, Cripton PA, Helgason B. Explicit Finite Element Models Accurately Predict Subject-Specific and Velocity-Dependent Kinetics of Sideways Fall Impact. J Bone Miner Res 2019; 34:1837-1850. [PMID: 31163090 DOI: 10.1002/jbmr.3804] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 05/16/2019] [Accepted: 05/23/2019] [Indexed: 11/09/2022]
Abstract
The majority of hip fractures in the elderly are the result of a fall from standing or from a lower height. Current injury models focus mostly on femur strength while neglecting subject-specific loading. This article presents an injury modeling strategy for hip fractures related to sideways falls that takes subject-specific impact loading into account. Finite element models (FEMs) of the human body were used to predict the experienced load and the femoral strength in a single model. We validated these models for their predicted peak force, effective pelvic stiffness, and fracture status against matching ex vivo sideways fall impacts (n = 11) with a trochanter velocity of 3.1 m/s. Furthermore, they were compared to sideways impacts of volunteers with lower impact velocities that were previously conducted by other groups. Good agreement was found between the ex vivo experiments and the FEMs with respect to peak force (root mean square error [RMSE] = 10.7%, R2 = 0.85) and effective pelvic stiffness (R2 = 0.92, RMSE = 12.9%). The FEMs were predictive of the fracture status for 10 out of 11 specimens. Compared to the volunteer experiments from low height, the FEMs overestimated the peak force by 25% for low BMI subjects and 8% for high BMI subjects. The effective pelvic stiffness values that were derived from the FEMs were comparable to those derived from impacts with volunteers. The force attenuation from the impact surface to the femur ranged between 27% and 54% and was highly dependent on soft tissue thickness (R2 = 0.86). The energy balance in the FEMS showed that at the time of peak force 79% to 93% of the total energy is either kinetic or was transformed to soft tissue deformation. The presented FEMs allow for direct discrimination between fracture and nonfracture outcome for sideways falls and bridge the gap between impact testing with volunteers and impact conditions representative of real life falls. © 2019 American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Ingmar Fleps
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - Pierre Guy
- Division of Orthopaedic Trauma, Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
| | | | - Peter A Cripton
- Orthopaedics and Injury Biomechanics Group, Department of Mechanical Engineering and Orthopaedics and School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada
| | | |
Collapse
|
25
|
Fleps I, Fung A, Guy P, Ferguson SJ, Helgason B, Cripton PA. Subject-specific ex vivo simulations for hip fracture risk assessment in sideways falls. Bone 2019; 125:36-45. [PMID: 31071479 DOI: 10.1016/j.bone.2019.05.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 04/17/2019] [Accepted: 05/04/2019] [Indexed: 12/18/2022]
Abstract
The risk of hip fracture of a patient due to a fall can be described from a mechanical perspective as the capacity of the femur to withstand the force that it experiences in the event of a fall. So far, impact forces acting on the lateral aspect of the pelvic region and femur strength have been investigated separately. This study used inertia-driven cadaveric impact experiments that mimic falls to the side from standing in order to evaluate the subject-specific force applied to the hip during impact and the fracture outcome in the same experimental model. Eleven fresh-frozen pelvis-femur constructs (6 female, 5 male, age = 77 years (SD = 13 years), BMI = 22.8 kg/m2 (SD = 7.8 kg/m2), total hip aBMD = 0.734 g/cm2 (SD = 0.149 g/cm2)), were embedded into soft tissue surrogate material that matched subject-specific mass and body shape. The specimens were attached to metallic lower-limb constructions with subject-specific masses and subjected to an inverted pendulum motion. Impact forces were recorded with a 6-axis force plate at 10,000 Hz and three dimensional deflections in the pelvic region were tracked with two high-speed cameras at 5000 Hz. Of the 11 specimens, 5 femur fractures and 3 pelvis fractures were observed. Three specimens did not fracture. aBMD alone did not reliably separate femur fractures from non-fractures. However, a mechanical risk ratio, which was calculated as the impact force divided by aBMD, classified specimens reliably into femur fractures and non-fractures. Single degree of freedom models, based on specimen kinetics, were able to predict subject-specific peak impact forces (RMSE = 2.55% for non-fractures). This study provides direct evidence relating subject-specific impact forces and subject-specific strength estimates and improves the assessment of the mechanical risk of hip fracture for a specific femur/pelvis combination in a sideways fall.
Collapse
Affiliation(s)
- Ingmar Fleps
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland; Orthopaedics and Injury Biomechanics Group, Departments of Mechanical Engineering and Orthopaedics and School of Biomedical Engineering, University of British Columbia, Vancouver, Canada.
| | - Anita Fung
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland; Orthopaedics and Injury Biomechanics Group, Departments of Mechanical Engineering and Orthopaedics and School of Biomedical Engineering, University of British Columbia, Vancouver, Canada
| | - Pierre Guy
- Division of Orthopaedic Trauma, Department of Orthopaedics, University of British Columbia, Vancouver, Canada
| | | | | | - Peter A Cripton
- Orthopaedics and Injury Biomechanics Group, Departments of Mechanical Engineering and Orthopaedics and School of Biomedical Engineering, University of British Columbia, Vancouver, Canada
| |
Collapse
|
26
|
Johnston JD, Kawalilak CE, Lanovaz JL, Kontulainen SA. A single-spring model predicts the majority of variance in impact force during a fall onto the outstretched hand. J Biomech 2019; 90:149-152. [DOI: 10.1016/j.jbiomech.2019.04.042] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 03/26/2019] [Accepted: 04/30/2019] [Indexed: 10/26/2022]
|
27
|
Keenan BE, Evans SL. Biomechanical testing of hip protectors following the Canadian Standards Association express document. Osteoporos Int 2019; 30:1205-1214. [PMID: 30941484 DOI: 10.1007/s00198-019-04914-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Accepted: 02/22/2019] [Indexed: 11/25/2022]
Abstract
UNLABELLED A variety of hip protectors are available, but it is not clear which is the most effective and there is no standard test to evaluate their performance. This is the first study that uses a standard mechanical test on hip protectors. Some protectors perform well but others are almost ineffective, providing little to no protection to the wearer during a fall. INTRODUCTION Each year, over 70,000 patients are admitted to hospital in the UK with hip fractures. There are a variety of commercial hip protectors currently available. However, it is not explicitly clear which is the most effective with regard to maximum force attenuation, whilst still being both comfortable for the user and providing reasonable force reduction if misplaced from the intended position. The numerous test methods reported in the literature have given conflicting results, making objective comparison difficult for users, researchers, and manufacturers alike. The Canadian Standards Association (CSA) has therefore published an express document (EXP-08-17) with a draft standard test method. This paper presents initial results for a range of hip protectors. METHODS Eighteen commercially available hip protectors were tested according to EXP-08-17. Each hip protector was impacted five times in correct anatomical alignment over the greater trochanter and once at 50 mm displacements in the anterior, posterior, and lateral directions. RESULTS Considerable differences were identified between individual hip protectors in their ability to reduce impact forces on the femur (between 3% and 36% reduction in peak force). The performance was reduced when misplaced in many cases (maximum reduction only 20%). CONCLUSIONS This is the first study that uses a standard mechanical test on hip protectors. Previous studies have used a variety of methods, making it difficult to interpret results. We hope that these results using a standard test method will facilitate the effective comparison of results, as well as providing useful data for clinicians, users, and purchasers.
Collapse
Affiliation(s)
- B E Keenan
- School of Engineering, Cardiff University, Queens Buildings, 14-17 The Parade, Cardiff, Wales, CF24 3AA, UK.
| | - S L Evans
- School of Engineering, Cardiff University, Queens Buildings, 14-17 The Parade, Cardiff, Wales, CF24 3AA, UK
| |
Collapse
|
28
|
Sarvi MN, Luo Y. Improving the prediction of sideways fall-induced impact force for women by developing a female-specific equation. J Biomech 2019; 88:64-71. [DOI: 10.1016/j.jbiomech.2019.03.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 03/01/2019] [Accepted: 03/12/2019] [Indexed: 11/29/2022]
|
29
|
Rajapakse CS, Gupta N, Evans M, Alizai H, Shukurova M, Hong AL, Cruickshank NJ, Tejwani N, Egol K, Honig S, Chang G. Influence of bone lesion location on femoral bone strength assessed by MRI-based finite-element modeling. Bone 2019; 122:209-217. [PMID: 30851438 PMCID: PMC6486650 DOI: 10.1016/j.bone.2019.03.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 02/22/2019] [Accepted: 03/05/2019] [Indexed: 12/21/2022]
Abstract
Currently, clinical determination of pathologic fracture risk in the hip is conducted using measures of defect size and shape in the stance loading condition. However, these measures often do not consider how changing lesion locations or how various loading conditions impact bone strength. The goal of this study was to determine the impact of defect location on bone strength parameters in both the sideways fall and stance-loading conditions. We recruited 20 female subjects aged 48-77 years for this study and performed MRI of the proximal femur. Using these images, we simulated 10-mm pathologic defects in greater trochanter, superior, middle, and inferior femoral head, superior, middle, and inferior femoral neck, and lateral, middle, and medial proximal diaphysis to determine the effect of defect location on change in bone strength by performing finite element analysis. We compared the effect of each osteolytic lesion on bone stiffness, strength, resilience, and toughness. For the sideways fall loading, defects in the inferior femoral head (12.21%) and in the greater trochanter (6.43%) resulted in the greatest overall reduction in bone strength. For the stance loading, defects in the mid femoral head (-7.91%) and superior femoral head (-7.82%) resulted in the greatest overall reduction in bone strength. Changes in stiffness, yield force, ultimate force, resilience, and toughness were not found to be significantly correlated between the sideways fall and stance-loading for the majority of defect locations, suggesting that calculations based on the stance-loading condition are not predictive of the change in bone strength experienced in the sideways fall condition. While stiffness was significantly related to yield force (R2 > 0.82), overall force (R2 > 0.59), and resilience (R2 > 0.55), in both, the stance-loading and sideways fall conditions for most defect locations, stiffness was not significantly related to toughness. Therefore, structure-dependent measure such as stiffness may not fully explain the post-yield measures, which depend on material failure properties. The data showed that MRI-based models have the sensitivity to determine the effect of pathologic lesions on bone strength.
Collapse
Affiliation(s)
| | - Nishtha Gupta
- University of Pennsylvania, Philadelphia, PA, United States of America
| | - Marissa Evans
- University of Pennsylvania, Philadelphia, PA, United States of America
| | - Hamza Alizai
- New York University, New York, NY, United States of America
| | - Malika Shukurova
- University of Pennsylvania, Philadelphia, PA, United States of America
| | - Abigail L Hong
- University of Pennsylvania, Philadelphia, PA, United States of America
| | | | - Nirmal Tejwani
- New York University, New York, NY, United States of America
| | - Kenneth Egol
- New York University, New York, NY, United States of America
| | - Stephen Honig
- New York University, New York, NY, United States of America
| | - Gregory Chang
- New York University, New York, NY, United States of America
| |
Collapse
|
30
|
Stroncek JD, Shaul JL, Favell D, Hill RS, Huber BM, Howe JG, Bouxsein ML. In vitro injection of osteoporotic cadaveric femurs with a triphasic calcium-based implant confers immediate biomechanical integrity. J Orthop Res 2019; 37:908-915. [PMID: 30793358 PMCID: PMC6593990 DOI: 10.1002/jor.24239] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Accepted: 01/21/2019] [Indexed: 02/04/2023]
Abstract
Current pharmaceutical therapies can reduce hip fractures by up to 50%, but compliance to treatment is low and therapies take up to 18 months to reduce risk. Thus, alternative or complementary approaches to reduce the risk of hip fracture are needed. The AGN1 local osteo-enhancement procedure (LOEP) is one such alternative approach, as it is designed to locally replace bone lost due to osteoporosis and provide immediate biomechanical benefit. This in vitro study evaluated the initial biomechanical impact of this treatment on human cadaveric femurs. We obtained 45 pairs of cadaveric femurs from women aged 77.8 ± 8.8 years. One femur of each pair was treated, while the contralateral femur served as an untreated control. Treatment included debridement, irrigation/suction, and injection of a triphasic calcium-based implant (AGN1). Mechanical testing of the femora was performed in a sideways fall configuration 24 h after treatment. Of the 45 pairs, 4 had normal, 16 osteopenic, and 25 osteoporotic BMD T-scores. Altogether, treatment increased failure load on average by 20.5% (p < 0.0001). In the subset of osteoporotic femurs, treatment increased failure load by 26% and work to failure by 45% (p < 0.01 for both). Treatment did not significantly affect stiffness in any group. These findings provide evidence that local delivery of the triphasic calcium-based implant in the proximal femur is technically feasible and provides immediate biomechanical benefit. Our results provide strong rationale for additional studies investigating the utility of this approach for reducing the risk of hip fracture. © 2019 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society.
Collapse
Affiliation(s)
- John D. Stroncek
- AgNovos Healthcare7301 Calhoun Place Suite 100RockvilleMaryland 20855
| | - Jonathan L. Shaul
- AgNovos Healthcare7301 Calhoun Place Suite 100RockvilleMaryland 20855
| | - Dominique Favell
- AgNovos Healthcare7301 Calhoun Place Suite 100RockvilleMaryland 20855
| | - Ronald S. Hill
- AgNovos Healthcare7301 Calhoun Place Suite 100RockvilleMaryland 20855
| | - Bryan M. Huber
- Copley Hospital528 Washington HwyMorrisvilleVermont 05661
| | - James G. Howe
- AgNovos Healthcare7301 Calhoun Place Suite 100RockvilleMaryland 20855
| | - Mary L. Bouxsein
- Center for Advanced Orthopedic Studies, Beth Israel Deaconess Medical Center and Dept. of Orthopedic SurgeryHarvard Medical School330 Brookline AveBostonMassachusetts 02215
| |
Collapse
|
31
|
Ruiz Wills C, Olivares AL, Tassani S, Ceresa M, Zimmer V, González Ballester MA, Del Río LM, Humbert L, Noailly J. 3D patient-specific finite element models of the proximal femur based on DXA towards the classification of fracture and non-fracture cases. Bone 2019; 121:89-99. [PMID: 30611923 DOI: 10.1016/j.bone.2019.01.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Revised: 12/21/2018] [Accepted: 01/01/2019] [Indexed: 11/18/2022]
Abstract
Osteoporotic bone fractures reduce quality of life and drastically increase mortality. Minimally irradiating imaging techniques such as dual-energy X-ray absorptiometry (DXA) allow assessment of bone loss through the use of bone mineral density (BMD) as descriptor. Yet, the accuracy of fracture risk predictions remains limited. Recently, DXA-based 3D modelling algorithms were proposed to analyse the geometry and BMD spatial distribution of the proximal femur. This study hypothesizes that such approaches can benefit from finite element (FE)-based biomechanical analyses to improve fracture risk prediction. One hundred and eleven subjects were included in this study and stratified in two groups: (a) 62 fracture cases, and (b) 49 non-fracture controls. Side fall was simulated using a static peak load that depended on patient mass and height. Local mechanical fields were calculated based on relationships between tissue stiffness and BMD. The area under the curve (AUC) of the receiver operating characteristic method evaluated the ability of calculated biomechanical descriptors to discriminate fracture and control cases. The results showed that the major principal stress was better discriminator (AUC > 0.80) than the volumetric BMD (AUC ≤ 0.70). High discrimination capacity was achieved when the analysis was performed by bone type, zone of fracture and gender/sex (AUC of 0.91 for women, trabecular bone and trochanter area), and outcomes suggested that the trabecular bone is critical for fracture discrimination. In conclusion, 3D FE models derived from DXA scans might significantly improve the prediction of hip fracture risk; providing a new insight for clinicians to use FE simulations in clinical practice for osteoporosis management.
Collapse
Affiliation(s)
| | | | - Simone Tassani
- BCN MedTech, Universitat Pompeu Fabra (UPF), Barcelona, Spain
| | - Mario Ceresa
- BCN MedTech, Universitat Pompeu Fabra (UPF), Barcelona, Spain
| | - Veronika Zimmer
- BCN MedTech, Universitat Pompeu Fabra (UPF), Barcelona, Spain; School of Biomedical Engineering & Imaging Sciences, King's College London, London, UK
| | | | | | | | - Jérôme Noailly
- BCN MedTech, Universitat Pompeu Fabra (UPF), Barcelona, Spain
| |
Collapse
|
32
|
Qu A, Wang D, Zeng X, Wang Q. Dynamic response and material sensitivity analysis of pelvic complex numerical model under side impact. Biomed Mater Eng 2018; 29:499-512. [PMID: 30282346 DOI: 10.3233/bme-181005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The surrogate design and clinical diagnostic suggest that the pelvic dynamic response should be the basis of bone fracture mechanism study under side impact. Pelvic response indicators are the impact force, compression (C), viscous criterion (VC), bone stress, and bone strain. However, no evaluation of these indicators has been conducted. OBJECTIVE To evaluate pelvic response indicators under side impact. METHODS A sitting pelvic finite element (FE) complex model comprising bone, artery, ligaments, and soft tissue was constructed. The dynamic response of the model under side impact with initial velocity of 3 m/s was investigated and material sensitivity analysis was complemented by changing bone elastic modulus. RESULTS The pelvic FE model could predict response under side impact. Specifically, the indicators such as artery pressure and strain, together with the ligaments axial force and strain were provided. The sensitivity analysis showed the impact force, bone stress, and axial force were sensitive to the elastic modulus, whereas, C, VC, bone strain, and artery pressure were not. CONCLUSIONS The sitting FE model in this study can predict pelvic dynamic response, and C, VC, bone strain and artery pressure are proposed for pelvic tolerance instead of impact force under side impact.
Collapse
Affiliation(s)
- Aili Qu
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China.,School of Mechanical Engineering, Ningxia University, Yinchuan, Ningxia, China
| | - Dongmei Wang
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Xiangsen Zeng
- First People's Hospital Affiliated to Shanghai Jiao Tong University, Shanghai, China
| | - Qiu'gen Wang
- First People's Hospital Affiliated to Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
33
|
Bhattacharya P, Altai Z, Qasim M, Viceconti M. A multiscale model to predict current absolute risk of femoral fracture in a postmenopausal population. Biomech Model Mechanobiol 2018; 18:301-318. [PMID: 30276488 PMCID: PMC6418062 DOI: 10.1007/s10237-018-1081-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2018] [Accepted: 09/24/2018] [Indexed: 02/06/2023]
Abstract
Osteoporotic hip fractures are a major healthcare problem. Fall severity and bone strength are important risk factors of hip fracture. This study aims to obtain a mechanistic explanation for fracture risk in dependence of these risk factors. A novel modelling approach is developed that combines models at different scales to overcome the challenge of a large space–time domain of interest and considers the variability of impact forces between potential falls in a subject. The multiscale model and its component models are verified with respect to numerical approximations made therein, the propagation of measurement uncertainties of model inputs is quantified, and model predictions are validated against experimental and clinical data. The main results are model predicted absolute risk of current fracture (ARF0) that ranged from 1.93 to 81.6% (median 36.1%) for subjects in a retrospective cohort of 98 postmenopausal British women (49 fracture cases and 49 controls); ARF0 was computed up to a precision of 1.92 percentage points (pp) due to numerical approximations made in the model; ARF0 possessed an uncertainty of 4.00 pp due to uncertainties in measuring model inputs; ARF0 classified observed fracture status in the above cohort with AUC = 0.852 (95% CI 0.753–0.918), 77.6% specificity (95% CI 63.4–86.5%) and 81.6% sensitivity (95% CI 68.3–91.1%). These results demonstrate that ARF0 can be computed using the model with sufficient precision to distinguish between subjects and that the novel mechanism of fracture risk determination based on fall dynamics, hip impact and bone strength can be considered validated.
Collapse
Affiliation(s)
- Pinaki Bhattacharya
- Department of Mechanical Engineering, University of Sheffield, The Sir Frederick Mappin Building, Mappin Street, Sheffield, S1 3JD, UK. .,INSIGNEO Institute for in Silico Medicine, University of Sheffield, The Pam Liversidge Building, Mappin Street, Sheffield, S1 3JD, UK.
| | - Zainab Altai
- Department of Mechanical Engineering, University of Sheffield, The Sir Frederick Mappin Building, Mappin Street, Sheffield, S1 3JD, UK.,INSIGNEO Institute for in Silico Medicine, University of Sheffield, The Pam Liversidge Building, Mappin Street, Sheffield, S1 3JD, UK
| | - Muhammad Qasim
- Department of Mechanical Engineering, University of Sheffield, The Sir Frederick Mappin Building, Mappin Street, Sheffield, S1 3JD, UK.,INSIGNEO Institute for in Silico Medicine, University of Sheffield, The Pam Liversidge Building, Mappin Street, Sheffield, S1 3JD, UK
| | - Marco Viceconti
- Department of Mechanical Engineering, University of Sheffield, The Sir Frederick Mappin Building, Mappin Street, Sheffield, S1 3JD, UK.,INSIGNEO Institute for in Silico Medicine, University of Sheffield, The Pam Liversidge Building, Mappin Street, Sheffield, S1 3JD, UK
| |
Collapse
|
34
|
Villette CC, Phillips ATM. Rate and age-dependent damage elasticity formulation for efficient hip fracture simulations. Med Eng Phys 2018; 61:1-12. [PMID: 30205937 DOI: 10.1016/j.medengphy.2018.07.016] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Revised: 06/11/2018] [Accepted: 07/29/2018] [Indexed: 10/28/2022]
Abstract
Prediction of bone failure is beneficial in a range of clinical situations from screening of osteoporotic patients with high fracture risk to assessment of protective equipment against trauma. Computational efficiency is an important feature to consider when developing failure models for iterative applications, such as patient-specific diagnosis or design of orthopaedic devices. The authors previously developed a methodology to generate efficient mesoscale structural full bone models. The aim of this study was to implement a damage elasticity formulation representative of an elasto-plastic material model with age and strain rate dependencies compatible with these structural models. This material model was assessed in the prediction of femoral fractures in longitudinal compression and side fall scenarios. The simulations predicted failure loads and fracture patterns in good agreement with reported results from experimental studies. The observed influence of strain rate on failure load was consistent with literature. The superiority of a simplified elasto-plastic formulation over an elasto-brittle bone material model was assessed. This computationally efficient damage elasticity formulation was capable of capturing fracture development after onset.
Collapse
Affiliation(s)
- C C Villette
- Structural Biomechanics, Department of Civil and Environmental Engineering, Imperial College London, England; The Royal British Legion Centre for Blast Injury Studies at Imperial College London, UK.
| | - A T M Phillips
- Structural Biomechanics, Department of Civil and Environmental Engineering, Imperial College London, England; The Royal British Legion Centre for Blast Injury Studies at Imperial College London, UK
| |
Collapse
|
35
|
Fleps I, Enns-Bray WS, Guy P, Ferguson SJ, Cripton PA, Helgason B. On the internal reaction forces, energy absorption, and fracture in the hip during simulated sideways fall impact. PLoS One 2018; 13:e0200952. [PMID: 30114192 PMCID: PMC6095517 DOI: 10.1371/journal.pone.0200952] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Accepted: 07/04/2018] [Indexed: 11/25/2022] Open
Abstract
The majority of hip fractures have been reported to occur as a result of a fall with impact to the greater trochanter of the femur. Recently, we developed a novel cadaveric pendulum-based hip impact model and tested two cadaveric femur-pelvis constructs, embedded in a soft tissue surrogate. The outcome was a femoral neck fracture in a male specimen while a female specimen had no fracture. The aim of the present study was, first, to develop a methodology for constructing and assessing the accuracy of explicit Finite Element Models (FEMs) for simulation of sideways falls to the hip based on the experimental model. Second, to use the FEMs for quantifying the internal reaction forces and energy absorption in the hip during impact. Third, to assess the potential of the FEMs in terms of separating a femoral fracture endpoint from a non-fracture endpoint. Using a non-linear, strain rate dependent, and heterogeneous material mapping strategy for bone tissue in these models, we found the FEM-derived results to closely match the experimental test results in terms of impact forces and displacements of pelvic video markers up to the time of peak impact force with errors below 10%. We found the internal reaction forces in the femoral neck on the impact side to be approximately 35% lower than the impact force measured between soft tissue and ground for both specimens. In addition, we found the soft tissue to be the component that absorbed the largest part of the energy of the tissue types in the hip region. Finally, we found surface strain patterns derived from FEM results to match the fracture location and extent based on post testing x-rays of the specimens. This is the first study with quantitative data on the energy absorption in the pelvic region during a sideways fall.
Collapse
Affiliation(s)
- Ingmar Fleps
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
- * E-mail:
| | | | - Pierre Guy
- Division of Orthopaedic Trauma, Department of Orthopaedics, University of British Columbia, Vancouver, Canada
| | | | - Peter A. Cripton
- Orthopaedics and Injury Biomechanics Group, Department of Mechanical Engineering and Orthopaedics and School of Biomedical Engineering, University of British Columbia, Vancouver, Canada
| | - Benedikt Helgason
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
- School of Science and Engineering, Reykjavik University, Reykjavik, Iceland
| |
Collapse
|
36
|
Lewandowski BE, Myers JG. Forecasting post-flight hip fracture probability using probabilistic modeling. J Biomech Eng 2018; 141:2697809. [PMID: 30128484 DOI: 10.1115/1.4041164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Indexed: 11/08/2022]
Abstract
A probabilistic model predicts hip fracture probability for post-flight male astronauts during lateral fall scenarios from various heights. A biomechanical representation of the hip provides impact load. Correlations relate spaceflight bone mineral density (BMD) loss and post-flight BMD recovery to bone strength. Translations convert fracture risk index, the ratio of applied load to bone strength, to fracture probability. Parameter distributions capture uncertainty and Monte Carlo simulations provide probability outcomes. The fracture probability for a 1 m fall 0 days post-flight is 15% greater than preflight and remains 6% greater than pre-flight at 365 days post-flight. Probability quantification provides insight into how spaceflight induced BMD loss affects fracture probability. A bone loss rate reflecting improved exercise countermeasures and dietary intake further reduces the post-flight fracture probability to 6% greater than preflight at 0 days post-flight and 2% greater at 365 days post-flight. Quantification informs assessments of countermeasure effectiveness. When preflight BMD is one standard deviation below mean astronaut preflight BMD, fracture probability at 0 days post-flight is 34% greater than the preflight fracture probability calculated with mean BMD and 28% greater at 365 days post-flight. Quantification aids review of astronaut BMD fitness for duty standards. Increases in post-flight fracture probability are associated with an estimated 18% reduction in post-flight bone strength. Therefore, a 0.82 deconditioning coefficient modifies force application limits for crew vehicles.
Collapse
Affiliation(s)
- Beth E Lewandowski
- NASA John H. Glenn Research Center, Low-gravity Exploration Technology Branch, Cleveland, OH, 44135
| | - Jerry G Myers
- NASA John H. Glenn Research Center, Low-gravity Exploration Technology Branch, Cleveland, OH, 44135
| |
Collapse
|
37
|
Fleps I, Vuille M, Melnyk A, Ferguson SJ, Guy P, Helgason B, Cripton PA. A novel sideways fall simulator to study hip fractures ex vivo. PLoS One 2018; 13:e0201096. [PMID: 30040858 PMCID: PMC6057661 DOI: 10.1371/journal.pone.0201096] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Accepted: 07/09/2018] [Indexed: 11/19/2022] Open
Abstract
Falls to the side are the leading cause of hip fractures in the elderly. The load that a person experiences during a fall cannot be measured with volunteers for ethical reasons. To evaluate injurious loads, while considering relevant energy input and body posture for a sideways fall, a subject-specific cadaveric impact experiment was developed. Full cadaveric femur-pelvis constructs (N = 2) were embedded in surrogate soft tissue material and attached to metallic surrogate lower limbs. The specimens were then subjected to an inverted pendulum motion, simulating a fall to the side with an impact to the greater trochanter. The load at the ground and the deformation of the pelvis were evaluated using a 6-axis force transducer and two high-speed cameras. Post-test, a trauma surgeon (PG) evaluated specimen injuries. Peak ground contact forces were 7132 N and 5641 N for the fractured and non-fractured specimen, respectively. We observed a cervical fracture of the femur in one specimen and no injuries in a second specimen, showing that the developed protocol can be used to differentiate between specimens at high and low fracture risk.
Collapse
Affiliation(s)
- Ingmar Fleps
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
- * E-mail:
| | - Muriel Vuille
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - Angela Melnyk
- Orthopaedics and Injury Biomechanics Group, Department of Mechanical Engineering and Orthopaedics and School of Biomedical Engineering, University of British Columbia, Vancouver, Canada
| | | | - Pierre Guy
- Division of Orthopaedic Trauma, Department of Orthopaedics, University of British Columbia, Vancouver, Canada
| | - Benedikt Helgason
- Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
- School of Science and Engineering, Reykjavik University, Reykjavik, Iceland
| | - Peter A. Cripton
- Orthopaedics and Injury Biomechanics Group, Department of Mechanical Engineering and Orthopaedics and School of Biomedical Engineering, University of British Columbia, Vancouver, Canada
| |
Collapse
|
38
|
Aldieri A, Terzini M, Osella G, Priola AM, Angeli A, Veltri A, Audenino A, Bignardi C. Osteoporotic hip fracture prediction: is T-score based criterion enough? A Hip Structural Analysis based model. J Biomech Eng 2018; 140:2686533. [PMID: 30029233 DOI: 10.1115/1.4040586] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Indexed: 11/08/2022]
Abstract
At present, the current gold-standard for osteoporosis diagnosis is based on bone mineral density measurement, which, however, has been demonstrated to poorly estimate fracture risk. Further parameters in the hands of the clinicians are represented by the Hip Structural Analysis (HSA) variables, which include geometric information of the proximal femur cross-section. The purpose of this study was to investigate the suitability of HSA parameters as additional hip fracture risk predictors. With this aim, twenty-eight three-dimensional patient-specific models of the proximal femur were built from CT images and a sideways fall condition was reproduced by finite element analyses. A tensile or compressive predominance based on minimum and maximum principal strains was determined at each volume element and a Risk Factor (RF) was calculated. The power of HSA variables combinations to predict the maximum superficial RF values was assessed by multivariate linear regression analysis. The optimal regression model, identified through the Akaike information criterion, only comprises two variables, the buckling ratio and the neck-shaft angle. In order to validate the study, the model was tested on two additional patients who suffered a hip fracture after a fall. The results classified the patients in the high risk level, confirming the prediction power of the adopted model.
Collapse
Affiliation(s)
- Alessandra Aldieri
- Polito Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi, 24 - 10129 Turin, Italy
| | - Mara Terzini
- Polito Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi, 24 - 10129 Turin, Italy
| | - Giangiacomo Osella
- Department of Clinical and Biological Sciences, Internal Medicine, San Luigi Gonzaga University Hospital, Orbassano, University of Torino, Regione Gonzole 10, 10043 Orbassano, Italy
| | - Adriano M Priola
- Department of Diagnostic Imaging, San Luigi Gonzaga University Hospital, Orbassano, University of Torino, Regione Gonzole 10, 10043 Orbassano, Italy
| | - Alberto Angeli
- Department of Internal Medicine, Department of Clinical and Biological Sciences, San Luigi Gonzaga University Hospital, Orbassano, University of Torino, Regione Gonzole 10, 10043 Orbassano, Italy
| | - Andrea Veltri
- Unit of Radiology, Department of Oncology, San Luigi Gonzaga University Hospital, Orbassano, University of Torino, Regione Gonzole 10, 10043 Orbassano, Italy
| | - Alberto Audenino
- Polito Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi, 24 - 10129 Turin, Italy
| | - Cristina Bignardi
- Polito Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Corso Duca degli Abruzzi, 24 - 10129 Turin, Italy
| |
Collapse
|
39
|
Martel DR, Levine IC, Pretty SP, Laing AC. The influence of muscle activation on impact dynamics during lateral falls on the hip. J Biomech 2018; 66:111-118. [DOI: 10.1016/j.jbiomech.2017.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 09/28/2017] [Accepted: 11/02/2017] [Indexed: 10/18/2022]
|
40
|
Screening for osteoporosis following non-vertebral fractures in patients aged 50 and older independently of gender or level of trauma energy-a Swiss trauma center approach. Arch Osteoporos 2017; 12:38. [PMID: 28391563 DOI: 10.1007/s11657-017-0334-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Accepted: 04/03/2017] [Indexed: 02/03/2023]
Abstract
UNLABELLED Screening in a standardized manner for osteoporosis in non-vertebral fracture patients aged 50 and older independently of both gender and level of trauma energy yielded the indication for osteoporotic therapy for every fourth male high-energy fracture patient. PURPOSE This study aimed to identify the rate of osteoporosis in patients of both genders after fracture independently of the underlying level of trauma energy. METHODS A random cohort of patients aged 50 or older with non-vertebral fractures participated in a standardized diagnostic protocol to evaluate the indication for treatment of osteoporosis (number needed to screen (NNS)). Univariate and multivariate analysis as well as correlation testing were performed to determine statistical relationships. Significance was set at p < 0.05. RESULTS Of 478 fracture patients with a mean age of 69.3 ± 11.8 years, 317 (66.3%) were female and 161 (33.7%) male. One hundred nineteen patients (24.9%) sustained high-energy fractures (HEFs) and 359 (75.1%) low-energy fractures (LEFs). Twenty-eight percent of males and 47% of females qualified as osteoporotic in densitometry (dual-energy X-ray absorptiometry (DXA)), resulting in a NNS of 2.1 for women and 3.6 for men. The indication for treatment of osteoporosis increased to an NNS of 1.5 for females and 2.4 for males if the fracture risk assessment tool (FRAX) was included in the diagnostics (DXA and FRAX). With regard to the energy of trauma, the NNS for treatment following DXA and FRAX was 1.5 for LEF and 2.9 for HEF. Subgroup analysis revealed that HEF males within the decennia 50+ and 80+ had an NNS of around 3, i.e., comparable to females and about twice as high as LEF patients. CONCLUSIONS These preliminary findings appear to confirm the pragmatic approach to screening in a standardized manner for osteoporosis in all non-vertebral fracture patients aged 50 and older-independently of both gender and level of trauma energy.
Collapse
|
41
|
Faisal TR, Luo Y. Study of the variations of fall induced hip fracture risk between right and left femurs using CT-based FEA. Biomed Eng Online 2017; 16:116. [PMID: 28974207 PMCID: PMC5627442 DOI: 10.1186/s12938-017-0407-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Accepted: 09/22/2017] [Indexed: 01/23/2023] Open
Abstract
Background Hip fracture of elderly people—suffering from osteoporosis—is a severe public health concern, which can be reduced by providing a prior assessment of hip fracture risk. Image-based finite element analysis (FEA) has been considered an effective computational tool to assess the hip fracture risk. Considering the femoral neck region is the weakest, fracture risk indicators (FRI) are evaluated for both single-legged stance and sideways fall configurations and are compared between left and right femurs of each subject. Quantitative Computed Tomography (QCT) scan datasets of thirty anonymous patients’ left and right femora have been considered for the FE models, which have been simulated with an equal magnitude of load applied to the aforementioned configurations. The requirement of bilateral hip assessment in predicting the fracture risk has been explored in this study. Results Comparing the sideways fall and single-legged stance, the FRI varies by 64 to 74% at the superior aspects and by 14 to 19% at the inferior surfaces of both the femora. The results of this in vivo analysis clearly substantiate that the fracture is expected to initiate at the superior surface of femoral neck region if a patient falls from his/her standing height. The distributions of FRI between the femurs vary considerably, and the variability is significant at the superior aspects. The p value (= 0.02) obtained from paired sample t-Test yields p value ≤ 0.05, which shows the evidence of variability of the FRI distribution between left and right femurs. Moreover, the comparison of FRIs between the left and right femur of men and women shows that women are more susceptible to hip fracture than men. Conclusions The results and statistical variation clearly signify a need for bilateral hip scanning in predicting hip fracture risk, which is clinically conducted, at present, based on one hip chosen randomly and may lead to inaccurate fracture prediction. This study, although preliminary, may play a crucial role in assessing the hip fractures of the geriatric population and thereby, reducing the cost of treatment by taking predictive measure.
Collapse
Affiliation(s)
- Tanvir R Faisal
- Department of Physical Medicine and Rehabilitation, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA.,Legs + Walking Lab, Shirley Ryan AbilityLab, Chicago, IL, 60610, USA
| | - Yunhua Luo
- Department of Mechanical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada.
| |
Collapse
|
42
|
Understanding Hip Fracture by QCT-Based Finite Element Modeling. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0266-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
43
|
Nasiri Sarvi M, Luo Y. Sideways fall-induced impact force and its effect on hip fracture risk: a review. Osteoporos Int 2017; 28:2759-2780. [PMID: 28730547 DOI: 10.1007/s00198-017-4138-5] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2017] [Accepted: 06/21/2017] [Indexed: 01/12/2023]
Abstract
UNLABELLED Osteoporotic hip fracture, mostly induced in falls among the elderly, is a major health burden over the world. The impact force applied to the hip is an important factor in determining the risk of hip fracture. However, biomechanical researches have yielded conflicting conclusions about whether the fall-induced impact force can be accurately predicted by the available models. It also has been debated whether or not the effect of impact force has been considered appropriately in hip fracture risk assessment tools. This study aimed to provide a state-of-the-art review of the available methods for predicting the impact force, investigate their strengths/limitations, and suggest further improvements in modeling of human body falling. METHODS We divided the effective parameters on impact force to two categories: (1) the parameters that can be determined subject-specifically and (2) the parameters that may significantly vary from fall to fall for an individual and cannot be considered subject-specifically. RESULTS The parameters in the first category can be investigated in human body fall experiments. Video capture of real-life falls was reported as a valuable method to investigate the parameters in the second category that significantly affect the impact force and cannot be determined in human body fall experiments. CONCLUSIONS The analysis of the gathered data revealed that there is a need to develop modified biomechanical models for more accurate prediction of the impact force and appropriately adopt them in hip fracture risk assessment tools in order to achieve a better precision in identifying high-risk patients. Graphical abstract Impact force to the hip induced in sideways falls is affected by many parameters and may remarkably vary from subject to subject.
Collapse
Affiliation(s)
- M Nasiri Sarvi
- Department of Mechanical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB, R3T 5V6, Canada.
- AI Incorporated, Toronto, Canada.
| | - Y Luo
- Department of Mechanical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB, R3T 5V6, Canada
- Department of Biomedical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, Canada
| |
Collapse
|
44
|
Pretty SP, Martel DR, Laing AC. The Influence of Body Mass Index, Sex, & Muscle Activation on Pressure Distribution During Lateral Falls on the Hip. Ann Biomed Eng 2017; 45:2775-2783. [DOI: 10.1007/s10439-017-1928-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Accepted: 09/14/2017] [Indexed: 10/18/2022]
|
45
|
Varga P, Hofmann-Fliri L, Blauth M, Windolf M. Prophylactic augmentation of the osteoporotic proximal femur-mission impossible? BONEKEY REPORTS 2016; 5:854. [PMID: 28018586 DOI: 10.1038/bonekey.2016.86] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Accepted: 11/01/2016] [Indexed: 11/09/2022]
Abstract
The high incidence of secondary hip fractures and the associated markedly increased mortality call for preventive actions that could help to avoid these injuries. By providing immediate strengthening and not relying on patient compliance, internal prophylactic augmentation of the osteoporotic proximal femur may overcome the main limitations of systemic bone drugs and wearable protective pads. However, such a method would have to provide sufficient and reliable strengthening effect with minimal risks and side effects to justify the need of an invasive treatment. The requirements for an internal reinforcement approach are thus strict and include mechanical, biological, clinical, ethical and financial criteria. Here we first attempt to describe the properties of an ideal augmentation method. Previously published methodologies and techniques developed at our research institute, including approaches using cements, metals, other materials or combined approaches, are then reviewed and evaluated according to these aspects. We conclude that none of the discussed methodologies appears to be able to deliver a sufficiently high gain-versus-risk ratio that could justify the clinical application and thus augmentation of the osteoporotic proximal femur remains a challenge. Finally, we provide suggestions for the development and evaluation of future strategies.
Collapse
Affiliation(s)
- Peter Varga
- AO Research Institute Davos , Davos Platz, Switzerland
| | | | - Michael Blauth
- Department for Trauma Surgery, Medical University Innsbruck , Innsbruck, Austria
| | | |
Collapse
|
46
|
Tsang WWN, Chan VWL, Wong HH, Yip TWC, Lu X. The effect of performing a dual-task on postural control and selective attention of older adults when stepping backward. J Phys Ther Sci 2016; 28:2806-2811. [PMID: 27821940 PMCID: PMC5088131 DOI: 10.1589/jpts.28.2806] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2016] [Accepted: 06/16/2016] [Indexed: 11/24/2022] Open
Abstract
[Purpose] The purpose of the study was to investigate the postural control and cognitive
performance of older adults when stepping backward with and without a concurrent cognitive
task. [Subjects and Methods] Thirty young adults and twenty-eight older adults (mean
age=21.3 ± 1.2 and 72.2 ± 5.7 years, respectively) were recruited. Participants were asked
to step backward and then maintain a single-leg stance for 10 seconds with and without a
concurrent auditory response task. The reaction time and error rate while performing the
cognitive task were recorded. Postural stability after stepping back was measured in terms
of total sway path and total sway area. [Results] The older subjects had significantly
longer reaction times and higher error rates in both single- and dual-tasking. When
dual-tasking, both groups had significantly longer reaction times than when
single-tasking. Only the older adults showed significantly higher error rates. The older
adults also had significantly longer total sway paths and larger total sway areas of
single-leg stance after stepping back. Neither group showed a significant difference in
total sway path and sway area between single- and dual-tasking. [Conclusion] Older adults
have poorer cognitive performance and postural stability during both single- and
dual-tasking. They tend to prioritize postural control over cognition in dual-tasking.
Collapse
Affiliation(s)
| | - Vito Wai-Lok Chan
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, China
| | - Henry Hei Wong
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, China
| | - Tony Wai-Cheong Yip
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, China
| | - Xi Lu
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, China; Department of Rehabilitation Medicine, China-Japan Friendship Hospital, China
| |
Collapse
|
47
|
Nasiri M, Luo Y. Study of sex differences in the association between hip fracture risk and body parameters by DXA-based biomechanical modeling. Bone 2016; 90:90-8. [PMID: 27292653 DOI: 10.1016/j.bone.2016.06.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 05/25/2016] [Accepted: 06/07/2016] [Indexed: 11/17/2022]
Abstract
There is controversy about whether or not body parameters affect hip fracture in men and women in the same way. In addition, although bone mineral density (BMD) is currently the most important single discriminator of hip fracture, it is unclear if BMD alone is equally effective for men and women. The objective of this study was to quantify and compare the associations of hip fracture risk with BMD and body parameters in men and women using our recently developed two-level biomechanical model that combines a whole-body dynamics model with a proximal-femur finite element model. Sideways fall induced impact force of 130 Chinese clinical cases, including 50 males and 80 females, were determined by subject-specific dynamics modeling. Then, a DXA-based finite element model was used to simulate the femur bone under the fall-induced loading conditions and calculate the hip fracture risk. Body weight, body height, body mass index, trochanteric soft tissue thickness, and hip bone mineral density were determined for each subject and their associations with impact force and hip fracture risk were quantified. Results showed that the association between impact force and hip fracture risk was not strong enough in both men (r=-0.31,p<0.05) and women (r=0.42,p<0.001) to consider the force as a sole indicator of hip fracture risk. The correlation between hip BMD and hip fracture risk in men (r=-0.83,p<0.001) was notably stronger than that in women (r=-0.68,p<0.001). Increased body mass index was not a protective factor against hip fracture in men (r=-0.13,p>0.05), but it can be considered as a protective factor among women (r=-0.28,p<0.05). In contrast to men, trochanteric soft tissue thickness can be considered as a protective factor against hip fracture in women (r=-0.50,p<0.001). This study suggested that the biomechanical risk/protective factors for hip fracture are sex-specific. Therefore, the effect of body parameters should be considered differently for men and women in hip fracture risk assessment tools. These findings support further exploration of sex-specific preventive and protective measurements to reduce the incidence of hip fractures.
Collapse
Affiliation(s)
- Masoud Nasiri
- Department of Mechanical Engineering, Faculty of Engineering, University of Manitoba, Canada
| | - Yunhua Luo
- Department of Mechanical Engineering, Faculty of Engineering, University of Manitoba, Canada; Department of Biomedical Engineering, Faculty of Engineering, University of Manitoba, Canada.
| |
Collapse
|
48
|
Faisal TR, Luo Y. Study of stress variations in single-stance and sideways fall using image-based finite element analysis. Biomed Mater Eng 2016; 27:1-14. [PMID: 27175463 DOI: 10.3233/bme-161563] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Image-based finite element analysis (FEA) has been considered an effective computational tool to predict hip fracture risk. The patient specific FEA gives an insight into the inclusive effect of three-dimensional (3D) complex bone geometry, and the distribution of inhomogeneous isotropic material properties in conjunction with loading conditions. The neck region of a femur is primarily the weakest in which fracture is likely to happen, when someone falls. A sideways fall results in the development of greater tensile and compressive stresses, respectively, in the inferior and superior aspects of the femoral neck, whereas the state of stress is reversed in usual gait or stance configuration. Herein, the variations of stresses have been investigated at the femoral neck region considering both single-stance and sideways fall. Finite element models of ten human femora have been generated using Quantitative Computed Tomography (QCT) scan datasets and have been simulated with an equal magnitude of load applied to the aforementioned configurations. Fracture risk indicator, defined as the ratio of the maximum compressive or tensile stress computed at the superior and inferior surfaces to the corresponding yield stress, has been used in this work to measure the variations of fracture risk between single-stance and sideways fall. The average variations of the fracture risk indicators between the fall and stance are at least 24.3% and 8% at the superior and inferior surfaces, respectively. The differences may interpret why sideways fall is more dangerous for the elderly people, causing hip fracture.
Collapse
Affiliation(s)
- Tanvir R Faisal
- Department of Mechanical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada. E-mails: ,
| | - Yunhua Luo
- Department of Mechanical Engineering, Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada. E-mails: ,
| |
Collapse
|
49
|
|
50
|
Luo Y. A biomechanical sorting of clinical risk factors affecting osteoporotic hip fracture. Osteoporos Int 2016; 27:423-39. [PMID: 26361947 DOI: 10.1007/s00198-015-3316-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2015] [Accepted: 09/03/2015] [Indexed: 02/07/2023]
Abstract
Osteoporotic fracture has been found associated with many clinical risk factors, and the associations have been explored dominantly by evidence-based and case-control approaches. The major challenges emerging from the studies are the large number of the risk factors, the difficulty in quantification, the incomplete list, and the interdependence of the risk factors. A biomechanical sorting of the risk factors may shed lights on resolving the above issues. Based on the definition of load-strength ratio (LSR), we first identified the four biomechanical variables determining fracture risk, i.e., the risk of fall, impact force, bone quality, and bone geometry. Then, we explored the links between the FRAX clinical risk factors and the biomechanical variables by looking for evidences in the literature. To accurately assess fracture risk, none of the four biomechanical variables can be ignored and their values must be subject-specific. A clinical risk factor contributes to osteoporotic fracture by affecting one or more of the biomechanical variables. A biomechanical variable represents the integral effect from all the clinical risk factors linked to the variable. The clinical risk factors in FRAX mostly stand for bone quality. The other three biomechanical variables are not adequately represented by the clinical risk factors. From the biomechanical viewpoint, most clinical risk factors are interdependent to each other as they affect the same biomechanical variable(s). As biomechanical variables must be expressed in numbers before their use in calculating LSR, the numerical value of a biomechanical variable can be used as a gauge of the linked clinical risk factors to measure their integral effect on fracture risk, which may be more efficient than to study each individual risk factor.
Collapse
Affiliation(s)
- Y Luo
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB, Canada.
- Department of Biomedical Engineering, University of Manitoba, Winnipeg, MB, Canada.
- Department of Anatomy, South Medical University, Guangzhou, China.
| |
Collapse
|