1
|
Abstract
The aim of this review paper is to concentrate on the use and application of photonics in dentistry. More than one hundred review and research articles were comprehensively analysed in terms of applications of photonics in dentistry, including surgical applications, as well as dental biomaterials, diagnosis and treatments. In biomedical engineering, various fields, such as biology, chemistry, material and physics, come together in to tackle a disease/disorder either as a diagnostic tool or an option for treatment. Engineers believe that biophotonics is the application of photonics in medicine, whereas photonics is simply a technology for creating and connecting packets of light energy, known as photons. This review paper provides a comprehensive discussion of its main elements, such as photoelasticity, interferometry techniques, optical coherence tomography, different types of lasers, carbon nanotubes, graphene and quantum dots.
Collapse
|
2
|
Comparison of Long-Wave and Mid-Wave Infrared Imaging Modalities for Photothermal Coherence Tomography of Human Teeth. IEEE Trans Biomed Eng 2022; 69:2755-2766. [PMID: 35196221 DOI: 10.1109/tbme.2022.3153209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The ability to detect dental caries at early stages lies at the heart of minimal intervention dentistry, enabling the curing or arresting of carious lesions before they advance to the cavity stage. Enhanced truncated-correlation photothermal coherence tomography (eTC-PCT) using mid-wave infrared (MWIR) cameras has recently been shown to offer tomographic visualization of early caries. The tomographic slicing ability of such systems, however, is believed to be limited by direct radiative thermal emission through the translucent dental enamel in the 3-5 m MWIR spectral range. Such radiative emissions can dominate the delayed conductive thermal contributions needed for tomographic reconstruction of internal dental defects. It has been hypothesized that long-wave infrared (LWIR) eTC-PCT systems may offer better tomographic performance by taking advantage of the intrinsic attenuation of direct radiative emission by dental enamel in the LWIR spectral range, enabling more effective delayed conductive thermal contributions from subsurface caries. More than an order of magnitude lower cost of the system is another key attribute of LWIR eTC-PCT which can open the door for downstream translation of the technology to clinics. In this report, we offer a systematic comparison of the performance/effectiveness of caries detection with LWIR and MWIR eTC-PCT systems for detecting natural caries, bacterial caries, and artificially demineralized enamel surfaces. Our results suggest that the low-cost LWIR based eTC-PCT system provides 3D visualization and 2D slice-by-slice images of early caries and internal micro-cracks similar to those obtained from the more expensive MWIR-based eTC-PCT system, albeit with ~1.3dB lower signal-to-noise ratio.
Collapse
|
3
|
Thermography as a non-ionizing quantitative tool for diagnosing periapical inflammatory lesions. BMC Oral Health 2021; 21:260. [PMID: 33985486 PMCID: PMC8120841 DOI: 10.1186/s12903-021-01618-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Accepted: 05/09/2021] [Indexed: 11/25/2022] Open
Abstract
Background Thermography is a contemporary imaging modality based on acquiring and analyzing thermal data using non-contact devices. The aim of the present study was to assess the validity of thermography, compared with that of the reference-standard, for the diagnosis of periapical inflammatory lesions and to evaluate the temperature ranges for acute pulpitis with apical periodontitis (AAP), acute periapical abscess (AA) and chronic periapical abscess (CA). Methods AAP, AA and CA were diagnosed based on clinical and radiographic criteria. Thermographic data were acquired using the FLIR E-5 Infrared Camera. Extraoral thermal images were taken from the front and right and left sides of patients whose mouths were closed, and one intraoral thermal image was taken from the palatal perspective. Agreement in the diagnoses based on the combination of clinical and radiographic assessments and the thermographic evaluation was calculated. The temperature ranges of the three diagnostic subgroups were also measured. Results A total of 80 patients were enrolled in this study. The mean intraoral thermal image temperature for AA was 37.26 ± 0.36, that for CA was 35.03 ± 0.63 and that for AAP was 36.07 ± 0.45. The differences between the mean intraoral thermal temperatures of the three diagnostic groups were statistically significant (P < 0.001). The result of the Kappa coefficient of agreement between the combination of clinical and radiographic assessments and the thermographic evaluation was significant (P < 0.001). Conclusions Thermography is an effective, quantitative and nonionizing approach that can be used for the diagnosis of periapical inflammatory lesions. The results of the present study indicated that the highest thermal image temperatures were recorded for AA. Thermography might be able to detect inflammatory reactions during the preclinical stage, leading to early diagnosis.
Collapse
|
4
|
Detection and monitoring of early dental caries and erosion using three-dimensional enhanced truncated-correlation photothermal coherence tomography imaging. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210053R. [PMID: 33928770 PMCID: PMC8084349 DOI: 10.1117/1.jbo.26.4.046004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 04/16/2021] [Indexed: 05/08/2023]
Abstract
SIGNIFICANCE Dental caries is the most common oral disease, with significant effects on healthcare systems and quality of life. Developing diagnostic methods for early caries detection is key to reducing this burden and enabling non-invasive treatment as opposed to the drill-and-fill approach. AIM The application of a thermophotonic-based 3D imaging modality [enhanced truncated-correlation photothermal coherence tomography (eTC-PCT)] to early dental caries is investigated. To this end, the detection threshold, sensitivity, and 3D lesion reconstruction capability of eTC-PCT in imaging artificially generated caries and surface erosion are evaluated. APPROACH eTC-PCT employs a diode laser with pulsed excitation, a mid-IR camera, and an in-house developed image reconstruction algorithm to produce depth-resolved 2D images and 3D reconstructions. Starting with healthy teeth, dental caries and surface erosion are simulated in vitro through application of specific demineralizing/eroding acidic solutions. RESULTS eTC-PCT can detect artificial caries as early as 2 days after onset of artificial demineralization and after 45 s of surface erosion, with a laser power equivalent to 64% of maximum permissible exposure. In both cases, the lesion is not visible to the eye and undetected by x-rays. eTC-PCT is capable of monitoring lesion progression in 2-day increments and generating 3D tomographic reconstructions of the advancing lesion. CONCLUSIONS eTC-PCT shows great potential for further development as a dental imaging modality combining low detection threshold, high sensitivity to lesion progression, 3D reconstruction capability, and lack of ionizing radiation. These features enable early diagnosis and frequent monitoring, making eTC-PCT a promising technology for facilitating preventive dentistry.
Collapse
|
5
|
Low-Cost Active Thermography using Cellphone Infrared Cameras: from Early Detection of Dental Caries to Quantification of THC in Oral Fluid. Sci Rep 2020; 10:7857. [PMID: 32398732 PMCID: PMC7217835 DOI: 10.1038/s41598-020-64796-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 04/21/2020] [Indexed: 11/24/2022] Open
Abstract
Active thermography (AT) is a widely studied non-destructive testing method for the characterization and evaluation of biological and industrial materials. Despite its broad range of potential applications, commercialization and wide-spread adaption of AT has long been impeded by the cost and size of infrared (IR) cameras. In this paper, we demonstrate that this cost and size limitation can be overcome using cell-phone attachment IR cameras. A software development kit (SDK) is developed that controls camera attributes through a simple USB interface and acquires camera frames at a constant frame rate up to 33 fps. To demonstrate the performance of our low-cost AT system, we report and discuss our experimental results on two high impact potential applications. The first set of experiments is conducted on a dental sample to investigate the clinical potential of the developed low-cost technology for detecting early dental caries, while the second set of experiments is conducted on the oral-fluid based lateral flow immunoassay to determine the viability of our technology for detecting and quantifying cannabis consumption at the point-of-care. Our results suggest achievement of reliable performance in the low-cost platform, comparable to those of costly and bulky research-grade systems, paving the way for translation of AT techniques to market.
Collapse
|
6
|
Thermographic detection and quantification of THC in oral fluid at unprecedented low concentrations. BIOMEDICAL OPTICS EXPRESS 2020; 11:2178-2190. [PMID: 32341875 PMCID: PMC7173880 DOI: 10.1364/boe.388990] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 03/11/2020] [Accepted: 03/14/2020] [Indexed: 06/11/2023]
Abstract
With recent changes in the legalization of cannabis around the world, there is an urgent need for rapid, yet sensitive, screening devices for testing drivers and employees under the influence of cannabis at the roadside and at the workplace, respectively. Oral fluid lateral flow immunoassays (LFAs) have recently been explored for such applications. While LFAs offer on-site, low-cost and rapid detection of tetrahydrocannabinol (THC), their nominal detection threshold is about 25 ng/ml, which is well above the 1-5 ng/ml per se limits set by regulations. In this paper, we report on the development of a thermo-photonic imaging system that utilizes the commercially available low-cost LFAs but offers detection of THC at unprecedented low concentrations. Our reader technology examines photothermal responses of gold nanoparticles (GNPs) in LFA through lock-in thermography (LIT). Our results (n = 300) suggest that the demodulation of localized surface plasmon resonance responses of GNPs captured by infrared cameras allows for detection of THC concentrations as low as 2 ng/ml with 96% accuracy. Quantification of THC concentration is also achievable with our technology through calibration.
Collapse
|
7
|
Signal amplification and quantification on lateral flow assays by laser excitation of plasmonic nanomaterials. Theranostics 2020; 10:4359-4373. [PMID: 32292500 PMCID: PMC7150487 DOI: 10.7150/thno.44298] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2020] [Accepted: 02/23/2020] [Indexed: 12/14/2022] Open
Abstract
Lateral flow assay (LFA) has become one of the most widely used point-of-care diagnostic methods due to its simplicity and low cost. While easy to use, LFA suffers from its low sensitivity and poor quantification, which largely limits its applications for early disease diagnosis and requires further testing to eliminate false-negative results. Over the past decade, signal enhancement strategies that took advantage of the laser excitation of plasmonic nanomaterials have pushed down the detection limit and enabled quantification of analytes. Significantly, these methods amplify the signal based on the current LFA design without modification. This review highlights these strategies of signal enhancement for LFA including surface enhanced Raman scattering (SERS), photothermal and photoacoustic methods. Perspectives on the rational design of the reader systems are provided. Future translation of the research toward clinical applications is also discussed.
Collapse
|
8
|
Demineralization detection in orthodontics using an ophthalmic optical coherence tomography device equipped with a multicolor fluorescence module. Clin Oral Investig 2019; 24:2579-2590. [PMID: 31848715 DOI: 10.1007/s00784-019-03116-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Accepted: 10/07/2019] [Indexed: 12/13/2022]
Abstract
OBJECTIVES Demineralizations such as white spot lesions are among the most prevalent side effects during orthodontic treatment. Fluorescence devices, including quantitative light-induced fluorescence (QLF), exploiting the intrinsic fluorescence of enamel and teeth and most recently optical coherence tomography (OCT) were introduced for early demineralization detection. In addition to near-infrared OCT scanning, multicolor modules allow for imaging with different laser wavelengths and the detection of reflective- and fluorescent light. The aim of this study was to evaluate a modified multicolor ophthalmic OCT device for the detection of early carious lesions in vitro and in vivo. MATERIALS AND METHODS Twenty-seven extracted lesion free human teeth were randomly assigned to three different demineralization protocols. Carious lesion detection was performed using macrophotography, OCT, and reflectance/fluorescence imaging using green laser and blue laser light. In addition, teeth of 5 orthodontic patients were OCT scanned, and fluorescence imaging using blue laser light was performed to assess demineralization after orthodontic therapy. RESULTS Both in vitro and in vivo, OCT allowed for precise determination of lesion depth and enamel loss. Fluorescence imaging using blue laser light was most sensitive for the detection of early demineralization in vitro and in vivo. However, established and severe demineralizations were also reliably detected by macrophotography in vitro and in vivo. CONCLUSION Demineralization can be detected with high sensitivity using blue fluorescence imaging with multicolor OCT devices. CLINICAL RELEVANCE In the future, OCT fluorescence imaging might be considered for longitudinal monitoring of dental hard tissue during orthodontic treatment in clinical trials.
Collapse
|
9
|
3D Dental Subsurface Imaging Using Enhanced Truncated Correlation-Photothermal Coherence Tomography. Sci Rep 2019; 9:16788. [PMID: 31727979 PMCID: PMC6856164 DOI: 10.1038/s41598-019-53170-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Accepted: 10/29/2019] [Indexed: 12/14/2022] Open
Abstract
Development of accurate and sensitive dental imaging technologies is a top priority in the pursuit of high-quality dental care. However, while early dental caries detection and routine monitoring of treatment progress are crucial for effective long-term results, current radiographic technologies fall short of this objective due to low sensitivity for small lesions and use of ionizing radiation which is unsuitable for frequent monitoring. Here we demonstrate the first application of enhanced Truncated Correlation-Photothermal Coherence Tomography (eTC-PCT) to dental imaging. eTC-PCT is non-invasive and non-ionizing, operates well below the maximum permissible exposure (MPE) limit, and features 3D subsurface imaging capability with operator controlled axial resolution. We explore the potential of this method for dental applications and demonstrate its capability for depth-resolved tomographic 3D reconstructions of the details and subsurface extent of a variety of dental defects. To this end, in this proof-of-concept study, dental eTC-PCT imaging results, and its sensitivity to dental caries, are discussed in comparison with visual examination, x-rays and micro-CT imaging.
Collapse
|
10
|
Incremental Low Rank Noise Reduction for Robust Infrared Tracking of Body Temperature during Medical Imaging. ELECTRONICS 2019. [DOI: 10.3390/electronics8111301] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Thermal imagery for monitoring of body temperature provides a powerful tool to decrease health risks (e.g., burning) for patients during medical imaging (e.g., magnetic resonance imaging). The presented approach discusses an experiment to simulate radiology conditions with infrared imaging along with an automatic thermal monitoring/tracking system. The thermal tracking system uses an incremental low-rank noise reduction applying incremental singular value decomposition (SVD) and applies color based clustering for initialization of the region of interest (ROI) boundary. Then a particle filter tracks the ROI(s) from the entire thermal stream (video sequence). The thermal database contains 15 subjects in two positions (i.e., sitting, and lying) in front of thermal camera. This dataset is created to verify the robustness of our method with respect to motion-artifacts and in presence of additive noise (2–20%—salt and pepper noise). The proposed approach was tested for the infrared images in the dataset and was able to successfully measure and track the ROI continuously (100% detecting and tracking the temperature of participants), and provided considerable robustness against noise (unchanged accuracy even in 20% additive noise), which shows promising performance.
Collapse
|
11
|
Truncated-correlation photothermal coherence tomography derivative imaging modality for small animal in vivo early tumor detection. OPTICS LETTERS 2019; 44:675-678. [PMID: 30702708 DOI: 10.1364/ol.44.000675] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Accepted: 12/20/2018] [Indexed: 06/09/2023]
Abstract
Early cancer non-invasive diagnosis is a leading medical topic worldwide due to the threat to human life and the high death rate of this disease. Light-absorption-based thermophotonic diagnostic imaging is well positioned for this challenge thanks to its speed, safety, and high molecular contrast advantages. In this Letter, an enhanced truncated-correlation photothermal coherence tomography (TC-PCT) imaging modality is presented for early in vivo tumor detection and tested using a nude mouse thigh. Compared with conventional TC-PCT, the enhanced imaging modality was found to exhibit higher contrast that contributed to the precise measurement of the size and shape of the detected tumor. The experimental results were validated following histological analysis from hematoxylin and eosin staining. This increased contrast advantage gives rise to possible clinical applications in early tumor detection and treatment and in monitoring the effects of anti-tumor drugs.
Collapse
|
12
|
Comparative study on the detection of early dental caries using thermo-photonic lock-in imaging and optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2018; 9:3983-3997. [PMID: 30615710 PMCID: PMC6157756 DOI: 10.1364/boe.9.003983] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Revised: 07/23/2018] [Accepted: 07/26/2018] [Indexed: 05/12/2023]
Abstract
Early detection of dental caries is known to be the key to the effectiveness of therapeutic and preventive approaches in dentistry. However, existing clinical detection techniques, such as radiographs, are not sufficiently sensitive to detect and monitor the progression of caries at early stages. As such, in recent years, several optics-based imaging modalities have been proposed for the early detection of caries. The majority of these techniques rely on the enhancement of light scattering in early carious lesions, while a few of them are based on the enhancement of light absorption at early caries sites. In this paper, we report on a systemic comparative study on the detection performances of optical coherence tomography (OCT) and thermophotonic lock-in imaging (TPLI) as representative early caries detection modalities based on light scattering and absorption, respectively. Through controlled demineralization studies on extracted human teeth and µCT validation experiments, several detection performance parameters of the two modalities such as detection threshold, sensitivity and specificity have been qualitatively analyzed and discussed. Our experiment results suggests that both modalities have sufficient sensitivity for the detection of well-developed early caries on occlusal and smooth surfaces; however, TPLI provides better sensitivity and detection threshold for detecting very early stages of caries formation, which is deemed to be critical for the effectiveness of therapeutic and preventive approaches in dentistry. Moreover, due to the more specific nature of the light absorption contrast mechanism over light scattering, TPLI exhibits better detection specificity, which results in less false positive readings and thus allows for the proper differentiation of early caries regions from the surrounding intact areas. The major shortcoming of TPLI is its inherent depth-integrated nature, prohibiting the production of depth-resolved/B-mode like images. The outcomes of this research justify the need for a light-absorption based imaging modality with the ability to produce tomographic and depth-resolved images, combining the key advantages of OCT and TPLI.
Collapse
|
13
|
|
14
|
Automated assessment and tracking of human body thermal variations using unsupervised clustering. APPLIED OPTICS 2016; 55:D162-D172. [PMID: 27958451 DOI: 10.1364/ao.55.00d162] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The presented approach addresses a review of the overheating that occurs during radiological examinations, such as magnetic resonance imaging, and a series of thermal experiments to determine a thermally suitable fabric material that should be used for radiological gowns. Moreover, an automatic system for detecting and tracking of the thermal fluctuation is presented. It applies hue-saturated-value-based kernelled k-means clustering, which initializes and controls the points that lie on the region-of-interest (ROI) boundary. Afterward, a particle filter tracks the targeted ROI during the video sequence independently of previous locations of overheating spots. The proposed approach was tested during experiments and under conditions very similar to those used during real radiology exams. Six subjects have voluntarily participated in these experiments. To simulate the hot spots occurring during radiology, a controllable heat source was utilized near the subject's body. The results indicate promising accuracy for the proposed approach to track hot spots. Some approximations were used regarding the transmittance of the atmosphere, and emissivity of the fabric could be neglected because of the independence of the proposed approach for these parameters. The approach can track the heating spots continuously and correctly, even for moving subjects, and provides considerable robustness against motion artifact, which occurs during most medical radiology procedures.
Collapse
|
15
|
First step toward translation of thermophotonic lock-in imaging to dentistry as an early caries detection technology. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:96003. [PMID: 27604562 DOI: 10.1117/1.jbo.21.9.096003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Accepted: 08/23/2016] [Indexed: 05/24/2023]
Abstract
Early detection of the most prevalent oral disease worldwide, i.e., dental caries, still remains as one of the major challenges in dentistry. The current dental standard of care relies on caries detection methods, such as visual inspection and x-ray radiography, which lack the sufficient specificity and sensitivity to detect caries at early stages of formation when they can be healed. We report on the feasibility of early caries detection in a clinically and commercially viable thermophotonic imaging system. The system incorporates intensity-modulated laser light along with a low-cost long-wavelength infrared (LWIR; 8 to 14???m) camera, providing diagnostic contrast based on the enhanced light absorption of early caries. The LWIR camera is highly suitable for integration into clinical platforms because of its low weight and cost. In addition, through theoretical modeling, we show that LWIR detection enhances the diagnostic contrast due to the minimal LWIR transmittance of enamel and suppression of the masking effect of the direct thermal Planck emission. Diagnostic performance of the system and its detection threshold are experimentally evaluated by monitoring the inception and progression of artificially induced occlusal and smooth surface caries. The results are suggestive of the suitability of the developed LWIR system for detecting early dental caries.
Collapse
|
16
|
On the sensitivity of thermophotonic lock-in imaging and polarized Raman spectroscopy to early dental caries diagnosis. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:025002. [PMID: 22463028 DOI: 10.1117/1.jbo.17.2.025002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Dental caries is the leading cause of tooth loss, which can promptly be prevented if detected in early stages of progression. Unfortunately, conventional diagnostic modalities currently used in dentistry lack the sensitivity to detect early caries. The authors' intention is to compare the ability of polarized Raman spectroscopy and thermophotonic imaging to make early caries diagnosis. Extracted human teeth with no visible stain or defects were artificially demineralized in accordance to a well-known protocol in dentistry for simulated early caries development at several demineralization stages. Samples were then inspected using polarized Raman spectroscopy and thermophotonic imaging. The sensitivities of these two diagnostic modalities are compared, and the results are verified using transverse micro-radiography. It was found that compared to polarized Raman spectroscopy, thermophotonic imaging exhibits superior sensitivity to very early stages of demineralization.
Collapse
|
17
|
Abstract
A coaxial thermal lens microscope was used to generate images based on both the absorbance and thermal diffusivity of histological samples. A pump beam was modulated at frequencies ranging from 50 kHz to 5 MHz using an acousto-optic modulator. The pump and a CW probe beam were combined with a dichroic mirror, directed into an inverted microscope, and focused onto the specimen. The change in the transmitted probe beam's center intensity was detected with a photodiode. The photodiode's signal and a reference signal from the modulator were sent to a high-speed lock-in amplifier. The in-phase and quadrature signals were recorded as a sample was translated through the focused beams and used to generate images based on the amplitude and phase of the lock-in amplifier's signal. The amplitude is related to the absorbance and the phase is related to the thermal diffusivity of the sample. Thin sections of stained liver and bone tissues were imaged; the contrast and signal-to-noise ratio of the phase image was highest at frequencies from 0.1-1 MHz and dropped at higher frequencies. The spatial resolution was 2.5 μm for both amplitude and phase images, limited by the pump beam spot size.
Collapse
|
18
|
Thermal coherence tomography using match filter binary phase coded diffusion waves. PHYSICAL REVIEW LETTERS 2011; 107:165901. [PMID: 22107403 DOI: 10.1103/physrevlett.107.165901] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2011] [Revised: 08/08/2011] [Indexed: 05/31/2023]
Abstract
Energy transport in diffusion-wave fields is gradient-driven and therefore diffuse, yielding depth-integrated responses with poor axial resolution. Using matched-filter principles, we propose a methodology enabling these parabolic diffusion-wave energy fields to exhibit energy localization akin to propagating hyperbolic wave fields. This not only improves axial resolution but also allows for deconvolution of individual responses of superposed axially discrete sources, opening a new field of depth-resolved subsurface thermal coherence tomography using diffusion waves.
Collapse
|
19
|
Highly depth-resolved chirped pulse photothermal radar for bone diagnostics. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2011; 82:074906. [PMID: 21806220 DOI: 10.1063/1.3616140] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A novel chirped pulse photothermal (PT) radiometric radar with improved sensitivity over the conventional harmonically modulated thermal-wave radar technique and alternative pulsed laser photothermal radiometry is introduced for the diagnosis of biological samples, especially bones with tissue and skin overlayers. The constraints imposed by the laser safety (maximum permissible exposure) ceiling on pump laser energy and the strong attenuation of thermal-wave signals in tissues significantly limit the photothermally active depth in most biological specimens to a level which is normally insufficient for practical applications (a few mm below the skin surface). A theoretical approach for improvement of signal-to-noise ratio (SNR), minimizing the static (dc) component of the photothermal signal and making use of the photothermal radiometric nonlinearity has been introduced and verified by comparing the SNR of four distinct excitation wave forms (sine-wave, square-wave, constant-width and constant duty-cycle pulses) for chirping the pump laser, under constant exposure energy. At low frequencies fixed-pulsewidth chirps of large peak power were found to be superior to all other equal-energy modalities, with an SNR improvement up to two orders of magnitude. Distinct thickness-dependent characteristic delay times in a goat bone were obtained, establishing an active depth resolution range of ~2.8 mm in a layered skin-fat-bone structure, a favorable result compared to the maximum reported pulsed photothermal radiometric depth resolution <1 mm in turbid biological media.
Collapse
|