1
|
Kobayashi S, Osanai T, Sugiyama T, Fujima N, Takagi R, Yokota I, Hamaguchi A, Nakamura T, Hida K, Fujimura M. Comparison of Access Route for Endovascular Treatment by Time-Spatial Labeling Inversion Pulse (Time-SLIP) MRA and Contrast-Enhanced MRA. JOURNAL OF NEUROENDOVASCULAR THERAPY 2023; 17:120-124. [PMID: 37547260 PMCID: PMC10400895 DOI: 10.5797/jnet.oa.2023-0001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Accepted: 04/26/2023] [Indexed: 08/08/2023]
Abstract
Objective In endovascular treatment, it is important to evaluate the access route for placing a catheter into the common carotid artery (CCA) promptly and safely prior to the procedure. We examined whether non-contrast MRA using time-spatial labeling inversion pulse (Time-SLIP) can be used in patients prior to endovascular thrombectomy for acute ischemic stroke. We compared Time-SLIP MRA to contrast-enhanced (CE) MRA and evaluated the efficacy in the evaluation of access routes. Methods We retrospectively reviewed 31 patients admitted between October 2018 and December 2018 for cerebral infarction at our hospital. Blood vessels were imaged from the aortic arch to the CCA. A radiologist blindly evaluated quality score, stenosis, shape of the aorta, and degree of tortuosity. Results There were no "non-diagnostic" images. The sensitivity, specificity, positive predictive value, and negative predictive value for stenosis were 83%, 96%, 83%, and 96%, respectively. The sensitivity for the aorta type classification was 100%. The sensitivity for mild tortuosity was 93%, for moderate was 100%, and for severe was 100%. Conclusion Time-SLIP MRA can be an alternative to CE MRA in access route assessment for patients with cerebral infarction who are not eligible for acute thrombectomy therapy.
Collapse
Affiliation(s)
- Satoshi Kobayashi
- Department of Neurosurgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
- Department of Neurosurgery, Sapporo Azabu Neurosurgical Hospital, Sapporo, Hokkaido, Japan
| | - Toshiya Osanai
- Department of Neurosurgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Taku Sugiyama
- Department of Neurosurgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Noriyuki Fujima
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Ryo Takagi
- Department of Biostatistics, Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Isao Yokota
- Department of Biostatistics, Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Akiyoshi Hamaguchi
- Department of Neurosurgery, Sapporo Azabu Neurosurgical Hospital, Sapporo, Hokkaido, Japan
| | - Toshitaka Nakamura
- Department of Neurosurgery, Sapporo Azabu Neurosurgical Hospital, Sapporo, Hokkaido, Japan
| | - Kazutoshi Hida
- Department of Neurosurgery, Sapporo Azabu Neurosurgical Hospital, Sapporo, Hokkaido, Japan
| | - Miki Fujimura
- Department of Neurosurgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| |
Collapse
|
2
|
Chen CW, Tseng YH, Kao CC, Ngo YG, Lee CY, Yang TY, Lin YH, Huang YK. Venous Segmental Flow Changes after Superficial Venous Intervention Demonstrating by Quantitative Phase-Contrast Magnetic Resonance Analysis: Preliminary Data from a Longitudinal Cohort Study. J Pers Med 2022; 12:jpm12061000. [PMID: 35743784 PMCID: PMC9224938 DOI: 10.3390/jpm12061000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 06/11/2022] [Accepted: 06/16/2022] [Indexed: 11/17/2022] Open
Abstract
The effects of superficial venous intervention on hemodynamics can be quantified using two-dimensional phase-contrast magnetic resonance imaging (2D PC-MRI). Twelve patients received pre- and postintervention 2D PC-MRI analysis using quantitative hemodynamic parameters. Fifteen healthy volunteers served as controls. The 2D PC-MRI results of the target limbs (limbs scheduled for intervention for venous reflux) differed from those of the controls in terms of stroke volume (SV), forward flow volume (FFV), absolute stroke volume (ASV), and mean flux (MF) in all venous segments. The velocity time integral (VTI) and mean velocity (MV) of the popliteal vein (PV) segments were similar between the target limbs and controls preoperatively. After intervention, the target limbs exhibited an increase in VTI and MV in the femoral vein (FV) and PV segments. We compared the target and nontreated limbs of the individual patients preoperatively and postoperatively to minimalize individual bias. All QFlow parameter ratios in the FV segment increased after venous intervention (VTI, p = 0.025; MV, p = 0.024). In the PV segment, FFV and ASV increased significantly (p = 0.035 and 0.024, respectively). After interventions, the volume (FFV and ASV) of the PV segment and the efficiency (VTI and MV) of the FV segment significantly increased.
Collapse
Affiliation(s)
- Chien-Wei Chen
- Department of Diagnostic Radiology, Chia Yi Chang Gung Memorial Hospital, Chiayi 61363, Taiwan;
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (C.-C.K.); (Y.G.N.); (C.-Y.L.); (T.-Y.Y.)
| | - Yuan-Hsi Tseng
- Department of Obstetrics and Gynecology, Chia Yi Chang Gung Memorial Hospital, Chiayi 61363, Taiwan;
| | - Chih-Chen Kao
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (C.-C.K.); (Y.G.N.); (C.-Y.L.); (T.-Y.Y.)
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Chiayi 61363, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Hospital, MOHW, Chiayi 61363, Taiwan
| | - Yeh Giin Ngo
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (C.-C.K.); (Y.G.N.); (C.-Y.L.); (T.-Y.Y.)
- Department of Obstetrics and Gynecology, Chia Yi Chang Gung Memorial Hospital, Chiayi 61363, Taiwan;
| | - Chung-Yuan Lee
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (C.-C.K.); (Y.G.N.); (C.-Y.L.); (T.-Y.Y.)
- Department of Obstetrics and Gynecology, Chia Yi Chang Gung Memorial Hospital, Chiayi 61363, Taiwan;
| | - Teng-Yao Yang
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (C.-C.K.); (Y.G.N.); (C.-Y.L.); (T.-Y.Y.)
- Cardiology, Chia Yi Chang Gung Memorial Hospital, Chiayi 61363, Taiwan;
| | - Yu-Hui Lin
- Cardiology, Chia Yi Chang Gung Memorial Hospital, Chiayi 61363, Taiwan;
| | - Yao-Kuang Huang
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan; (C.-C.K.); (Y.G.N.); (C.-Y.L.); (T.-Y.Y.)
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Chiayi 61363, Taiwan
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Hospital, MOHW, Chiayi 61363, Taiwan
- Correspondence:
| |
Collapse
|
3
|
Chen CW, Fang YF, Tseng YH, Wong MY, Lin YH, Hsu YC, Lin BS, Huang YK. Before and after Endovascular Aortic Repair in the Same Patients with Aortic Dissection: A Cohort Study of Four-Dimensional Phase-Contrast Magnetic Resonance Imaging. Diagnostics (Basel) 2021; 11:diagnostics11101912. [PMID: 34679608 PMCID: PMC8534695 DOI: 10.3390/diagnostics11101912] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 10/09/2021] [Accepted: 10/14/2021] [Indexed: 11/16/2022] Open
Abstract
(1) Background: We used four-dimensional phase-contrast magnetic resonance imaging (4D PC-MRI) to evaluate the impact of an endovascular aortic repair (TEVAR) on aortic dissection. (2) Methods: A total of 10 patients received 4D PC-MRI on a 1.5-T MR both before and after TEVAR. (3) Results: The aortas were repaired with either a GORE TAG Stent (Gore Medical; n = 7) or Zenith Dissection Endovascular Stent (Cook Medical; n = 3). TEVAR increased the forward flow volume of the true lumen (TL) (at the abdominal aorta, p = 0.047). TEVAR also reduced the regurgitant fraction in the TL at the descending aorta but increased it in the false lumen (FL). After TEVAR, the stroke distance increased in the TL (at descending and abdominal aorta, p = 0.018 and 0.015), indicating more effective blood transport per heartbeat. Post-stenting quantitative flow revealed that the reductions in stroke volume, backward flow volume, and absolute stroke volume were greater when covered stents were used than when bare stents were used in the FL of the descending aorta. Bare stents had a higher backward flow volume than covered stents did. (4) Conclusions: TEVAR increased the stroke volume in the TL and increased the regurgitant fraction in the FL in patients with aortic dissection.
Collapse
Affiliation(s)
- Chien-Wei Chen
- Department of Diagnostic Radiology, Chia Yi Chang Gung Memorial Hospital, Putzu City 61363, Taiwan; (C.-W.C.); (Y.-C.H.)
- Department of Diagnostic Radiology, Chang Gung University, Taoyuan 33302, Taiwan
| | - Yueh-Fu Fang
- Department of Thoracic Medicine, Linkou Chang Gung Memorial Hospital, Taoyuan 33302, Taiwan; (Y.-F.F.); (Y.-H.T.)
- Department of Thoracic Medicine, Chang Gung University, College of Medicine, Taoyuan 33302, Taiwan
| | - Yuan-Hsi Tseng
- Department of Thoracic Medicine, Linkou Chang Gung Memorial Hospital, Taoyuan 33302, Taiwan; (Y.-F.F.); (Y.-H.T.)
- Department of Thoracic Medicine, Chang Gung University, College of Medicine, Taoyuan 33302, Taiwan
| | - Min Yi Wong
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Putzu City 61363, Taiwan; (M.Y.W.); (Y.-H.L.)
- Division of Thoracic and Cardiovascular Surgery, Chang Gung University, Taoyuan 33302, Taiwan
| | - Yu-Hui Lin
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Putzu City 61363, Taiwan; (M.Y.W.); (Y.-H.L.)
- Division of Thoracic and Cardiovascular Surgery, Chang Gung University, Taoyuan 33302, Taiwan
| | - Yin-Chen Hsu
- Department of Diagnostic Radiology, Chia Yi Chang Gung Memorial Hospital, Putzu City 61363, Taiwan; (C.-W.C.); (Y.-C.H.)
- Department of Diagnostic Radiology, Chang Gung University, Taoyuan 33302, Taiwan
| | - Bor-Shyh Lin
- Institute of Imaging and Biomedical Photonics, National Yang Ming Chiao Tung University, Tainan 71150, Taiwan;
- Department of Medical Research, Chi-Mei Medical Center, Tainan 30010, Taiwan
| | - Yao-Kuang Huang
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Putzu City 61363, Taiwan; (M.Y.W.); (Y.-H.L.)
- Division of Thoracic and Cardiovascular Surgery, Chang Gung University, Taoyuan 33302, Taiwan
- Correspondence:
| |
Collapse
|
4
|
A Novel Tool for a Challenging Disease: Stasis Leg Ulcers Assessed Using QFlow in Triggered Angiography Noncontrast Enhanced Magnetic Resonance Imaging. J Pers Med 2021; 11:jpm11090857. [PMID: 34575634 PMCID: PMC8472672 DOI: 10.3390/jpm11090857] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 08/25/2021] [Accepted: 08/26/2021] [Indexed: 02/07/2023] Open
Abstract
Imaging characteristics of stasis leg ulcers (SLUs) are not easily demonstrated through existing diagnostic tools. Early diagnosis and treatment are crucial. This pilot study was conducted to assess the quantitative flow (QFlow) in triggered angiography noncontrast enhanced (TRANCE) magnetic resonance imaging (MRI) to identify the hemodynamics of victims with stasis leg ulcers (SLUs). This study included 33 patients with SLUs and 14 healthy controls (HC). The 33 patients with SLUs were divided into a reflux (15 patients) and a nonreflux group (18 patients). QFlow was done in the reflux, the nonreflux, and the HC. The stroke volume (SV), forward flow volume (FFV), absolute flow volume (AFV), mean flow (MF), and mean velocity (MV) were higher in the reflux than in the HC group in most segments, namely the external iliac vein (EIV), popliteal vein (PV), and great saphenous vein (GSV) (SV, p = 0.008; FFV, p = 0.008; absolute stroke volume (ASV), p = 0.008; MF, p = 0.002; MV, p = 0.009). No differences in the QFlow patterns were found in the GSV segment between the nonreflux group and the HC. Excellent performance in discriminating SLU with superficial venous reflux was reported for SV in the EIV and the PV (area under the curve (AUC) = 0.851 and 0.872), FFV in the EIV and PV (AUC = 0.854 and 0.869), ASV in the EIV and PV (AUC = 0.848 and 0.881), and MF in the EIV and PV (AUC = 0.866 and 0.868). The cutoff levels of SV/FFV/ASV/MF in the EIV/FV/PV/GSV for discriminating the SLU with superficial venous reflux were identified (p < 0.005). In conclusion, SLUs present different QFlow patterns by different etiology. The QFlow parameters of all vessel segments were higher in the morbid limbs of the reflux group than HC. The GSV segment of the nonreflux group displayed a pattern like the HC.
Collapse
|
5
|
Chen CW, Tseng YH, Wong MY, Lin YH, Yang TY, Hsu YC, Lin BS, Huang YK. Using Non-Contrast MRA to Discriminate between Obstructive and Nonobstructive Venous Diseases of the Legs. Diagnostics (Basel) 2021; 11:1392. [PMID: 34441326 PMCID: PMC8394703 DOI: 10.3390/diagnostics11081392] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 07/25/2021] [Accepted: 07/29/2021] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND Venous interventions of the legs are less predictable owing to a lock of objective tools. METHODS One hundred and twenty patients with lower extremity venous disease were evaluated anatomically using TRANCE MRI. Then, a QFlow analysis was performed in 53 patients with only one leg affected for hemodynamic evaluation. Those patients with complete QFlow were classified into obstructive and nonobstructive. RESULTS The QFlow-namely, stroke volume, forward flow volume, mean flux, stroke distance (SD), and mean velocity (MV) in the external iliac vein (EIV), femoral vein (FV), popliteal vein (PV), and great saphenous vein (GSV). The obstructed group had a shorter SD and lower MV in the EIV, EIV/FV, and GSV/PV (SD: p-values of 0.025, 0.05, and 0.043, respectively; MV: p-values of 0.02, 0.05, and 0.048, respectively). A good performance in discriminating obstructive venous disease was reported for SD in the EIV (area under the curve (AUC) = 67.9%, 95% confidence interval (CI) = 53.2-82.7%), EIV/FV (AUC = 72.4%, 95% CI = 58.2-86.5%), and GSV/PV (AUC = 67.9%, 95% CI = 51.7-84.1%). The SD in the EIV, EIV/FV, and GSV/PV had the ability to discriminate between obstructive and nonobstructive diseases (p-values of 0.025, 0.005, and 0.043). The MV in the EIV, EIV/FV, and GSV/PV had ability to discriminate between obstructive and nonobstructive venous diseases (p-values of 0.02, 0.005, and 0.048). CONCLUSIONS The SD and MV were lower for obstructive than nonobstructive disease in the EIV.
Collapse
Affiliation(s)
- Chien-Wei Chen
- Department of Diagnostic Radiology, Chia Yi Chang Gung Memorial Hospital and Chang Gung University, Chiayi 61363, Taiwan; (C.-W.C.); (Y.-C.H.)
| | - Yuan-Hsi Tseng
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital and Chang Gung University, Taoyuan 33323, Taiwan; (Y.-H.T.); (M.Y.W.); (Y.-H.L.)
| | - Min Yi Wong
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital and Chang Gung University, Taoyuan 33323, Taiwan; (Y.-H.T.); (M.Y.W.); (Y.-H.L.)
| | - Yu-Hui Lin
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital and Chang Gung University, Taoyuan 33323, Taiwan; (Y.-H.T.); (M.Y.W.); (Y.-H.L.)
| | - Teng-Yao Yang
- Department of Cardiology, Chia Yi Chang Gung Memorial Hospital and Chang Gung University, Taoyuan 33323, Taiwan;
| | - Yin-Chen Hsu
- Department of Diagnostic Radiology, Chia Yi Chang Gung Memorial Hospital and Chang Gung University, Chiayi 61363, Taiwan; (C.-W.C.); (Y.-C.H.)
| | - Bor-Shyh Lin
- Institute of Imaging and Biomedical Photonics, National Yang Ming Chiao Tung University and Department of Medical Research, Chi-Mei Medical Center, Tainan 71004, Taiwan;
| | - Yao-Kuang Huang
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital and Chang Gung University, Taoyuan 33323, Taiwan; (Y.-H.T.); (M.Y.W.); (Y.-H.L.)
| |
Collapse
|
6
|
Chen CW, Tseng YH, Lin CC, Kao CC, Wong MY, Ting H, Huang YK. Aortic dissection assessment by 4D phase-contrast MRI with hemodynamic parameters: the impact of stent type. Quant Imaging Med Surg 2021; 11:490-501. [PMID: 33532250 DOI: 10.21037/qims-20-670] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Background To explore the diagnostic performance of 4-dimensional phase-contrast magnetic resonance imaging (4D PC-MRI) in evaluating aortic dissection in different clinical scenarios. Methods The study group comprised 32 patients with a known aortic dissection who each underwent computed tomography angiography (CTA), and then 4D PC-MRI with a 1.5-T MR scanner. The 4D PC-MRI images were compared with the CTA images to evaluate the aortic size, branch identification, and iliac and femoral arterial access. Results The patients were divided into three groups: (I) patients diagnosed with Type B aortic dissection but did not undergo intervention (n=8); (II) patients with residual aortic dissection after open repair of Type A dissection (n=7); (III) patients who underwent endovascular aortic repair with or without open surgery (n=17). Without radiation or contrast media injection, 4D PC-MRI provided similar aortic images for patients in Group 1 and most of those in Group 2. In Group 3, stainless steel stents affected image quality in three patients. High-quality 4D PC-MRI images were obtained for the remaining 14 patients in Group 3, who had non-stainless steel stents, and provided major aortic information comparable to that provided by CTA with contrast media. The hemodynamic parameters of true and false lumens were evaluated between three patients with Type B aortic dissections and three patients who underwent thoracic endovascular aortic repair for their aortic dissection. The stroke volume was higher in the true lumen of the patients with stent-grafts than in the patients with Type B aortic dissection without intervention. The regurgitant fraction, an indicator of nonlaminar flow, was higher in the false lumens than in the true lumens. All 32 patients in this study tolerated 4D PC-MRI without adverse events. Conclusions 4D PC-MRI is radiation- and contrast media-free option for imaging aortic dissection. It not only provided images comparable in quality to those obtained with CTA but also provided information on hemodynamic parameters, including endoleak detection after thoracic endovascular aortic repair. 4D PC-MRI was safe and accurate in evaluating chronic Type B aortic dissection and residual aortic dissection after surgery for acute Type A aortic dissection. Therefore, it could be a potential tool in treating pathology in aortic dissection, especially for patients with malperfusion syndrome of visceral vessels and in young patients with renal function impairment. However, certain endograft materials, especially stainless steel, may prevent the further application of 4D PC-MRI and should be avoided.
Collapse
Affiliation(s)
- Chien-Wei Chen
- Institute of Medicine, Chung Shan Medical University, Taichung.,Department of Diagnostic Radiology, Chang Gung Memorial Hospital Chiayi Branch, College of Medicine, Chang Gung University, Chiayi and Taoyuan
| | - Yuan-Hsi Tseng
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Chiayi.,Chang Gung University, College of Medicine, Taoyuan
| | - Chien-Chao Lin
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Chiayi.,Chang Gung University, College of Medicine, Taoyuan
| | - Chih-Chen Kao
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Chiayi.,Chang Gung University, College of Medicine, Taoyuan
| | - Min Yi Wong
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Chiayi
| | - Hua Ting
- Institute of Medicine, Chung Shan Medical University, Taichung
| | - Yao-Kuang Huang
- Division of Thoracic and Cardiovascular Surgery, Chia Yi Chang Gung Memorial Hospital, Chiayi.,Chang Gung University, College of Medicine, Taoyuan
| |
Collapse
|
7
|
Stasis Leg Ulcers: Venous System Revises by Triggered Angiography Non-Contrast-Enhanced Sequence Magnetic Resonance Imaging. Diagnostics (Basel) 2020; 10:diagnostics10090707. [PMID: 32957628 PMCID: PMC7554685 DOI: 10.3390/diagnostics10090707] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/29/2020] [Accepted: 09/15/2020] [Indexed: 01/06/2023] Open
Abstract
Objectives: The distribution of venous pathology in stasis leg ulcers is unclear. The main reason for this uncertainty is the lack of objective diagnostic tools. To fill this gap, we assessed the effectiveness of triggered angiography non-contrast-enhanced (TRANCE)-magnetic resonance imaging (MRI) in determining the venous status of patients with stasis leg ulcers. Methods: This prospective observational study included the data of 23 patients with stasis leg ulcers who underwent TRANCE-MRI between April 2017 and May 2020; the data were retrospectively analyzed. TRANCE MRI utilizes differences in vascular signal intensity during the cardiac cycle for subsequent image subtraction, providing not only a venogram but also an arteriogram without the use of contrast agents or radiation. Results: TRANCE MRI revealed that the stasis leg ulcers of nine of the 23 patients could be attributed to valvular insufficiency and venous occlusion (including deep venous thrombosis [DVT], May–Thurner syndrome, and other external compression). Moreover, TRANCE MRI demonstrated no venous pathology in five patients (21.7%). We analyzed TRANCE MRI hemodynamic parameters, namely stroke volume, forward flow volume, backward flow volume, regurgitant fraction, absolute volume, mean flux, stroke distance, and mean velocity, in the external iliac vein, femoral vein, popliteal vein, and great saphenous vein (GSV) in three of the patients with valvular insufficiency and three of those with venous occlusion. We found that the mean velocity and stroke volume in the GSV was higher than that in the popliteal vein in all patients with venous valvular insufficiency. Conclusions: Stasis leg ulcers may have no underlying venous disease and could be confirmed by TRANCE-MRI. TRANCE MRI has good Interrater reliability between Duplex study in greater saphenous venous insufficiency. It also potentially surpasses existing diagnostic modalities in terms of distinguishable hemodynamic figures. Accordingly, TRANCE-MRI is a safe and useful tool for examining stasis leg ulcers and is extensively applied currently.
Collapse
|
8
|
Altaha MA, Jaskolka JD, Tan K, Rick M, Schmitt P, Menezes RJ, Wintersperger BJ. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques. Eur Radiol 2016; 27:1218-1226. [DOI: 10.1007/s00330-016-4448-6] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2016] [Revised: 05/17/2016] [Accepted: 05/23/2016] [Indexed: 12/17/2022]
|
9
|
|
10
|
Nielsen YW, Thomsen HS. Contrast-enhanced peripheral MRA: technique and contrast agents. Acta Radiol 2012; 53:769-77. [PMID: 22843836 DOI: 10.1258/ar.2012.120008] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X-ray angiography.
Collapse
Affiliation(s)
- Yousef W Nielsen
- Deparment of Radiology, Copenhagen University Hospital Bispebjerg, Bispebjerg
| | - Henrik S Thomsen
- Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, Denmark
| |
Collapse
|
11
|
Takehara Y, Yamashita S, Sakahara H, Masui T, Isoda H. Magnetic resonance angiography of the aorta. Ann Vasc Dis 2011; 4:271-85. [PMID: 23555465 DOI: 10.3400/avd.di.11.00822] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2011] [Accepted: 08/22/2011] [Indexed: 11/13/2022] Open
Abstract
Magnetic resonance angiography (MRA) is capable of imaging arteries in the half to whole body by a single acquisition without a nephrotoxic contrast medium, and acquired images can be reconstructed into a specific cross-sectional view in an arbitrary directions. MRA is applicable for vessels non-reachable by a catheter approach, and collateral vessels can be fully visualized. Since MRA is minimally-invasive with no exposure to ionized radiation, it can be repeatedly applied for follow-up. However, there are also disadvantages: the temporal and spatial resolutions are inferior to those of X-ray angiography, and, at present, it cannot be used as a guide for intervention. Moreover, gadolinium administrations may cause NSF in patients who have lost renal function, as a new risk. Accordingly, strict consideration is required for an indication of its application. Development of non-contrast MRA and evaluation of the wall itself may draw more attention in the future. Plaque imaging is being routinely performed nowadays, and the measurement of vascular wall shear stress, which has a close association with arteriosclerosis, may become possible by utilizing the time-resolved phase-contrast method capable of measuring the time-resolved velocity vectors of blood flow throughout the body. (*English Translation of J Jpn Coll Angiol, 2009, 49: 503-516.).
Collapse
Affiliation(s)
- Yasuo Takehara
- Radiology, Hamamatsu University Hospital, Hamamatsu, Shizuoka, Japan
| | | | | | | | | |
Collapse
|
12
|
Bui BT, Miller S, Mildenberger P, Sam A, Sheng R. Comparison of contrast-enhanced MR angiography to intraarterial digital subtraction angiography for evaluation of peripheral arterial occlusive disease: Results of a phase III multicenter trial. J Magn Reson Imaging 2010; 31:1402-10. [DOI: 10.1002/jmri.22086] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|
13
|
Magnetic resonance angiography: current status in the planning and follow-up of endovascular treatment in lower-limb arterial disease. Cardiovasc Intervent Radiol 2009; 32:397-405. [PMID: 19130124 DOI: 10.1007/s00270-008-9467-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2008] [Revised: 10/13/2008] [Accepted: 10/16/2008] [Indexed: 10/21/2022]
Abstract
Magnetic resonance angiography (MRA) has become an established imaging modality in the management of lower-limb arterial disease, with emerging roles in treatment planning and follow-up. Contrast-enhanced MRA is now the most widely used technique with clinically acceptable results in the majority of patients. Difficulties in imaging and image interpretation are recognised in certain subgroups, including patients with critical limb ischaemia as well as patients with stents. Although newer contrast agents and refined imaging protocols may offer some solutions to these problems, this optimism is balanced by concerns about the toxicity of certain gadolinium chelates. Further development of interventional MRA remains one of the most significant challenges in the development of magnetic resonance imaging-guided peripheral vascular intervention. The status of MRA in managing patients with lower-limb arterial disease in current clinical practice is reviewed.
Collapse
|
14
|
Rybicki FJ, Nallamshetty L, Yucel EK, Holtzman SR, Baum RA, Foley WD, Ho VB, Mammen L, Narra VR, Stein B, Moneta GL. ACR Appropriateness Criteria® on Recurrent Symptoms Following Lower-Extremity Angioplasty. J Am Coll Radiol 2008; 5:1176-80. [DOI: 10.1016/j.jacr.2008.08.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2008] [Indexed: 11/24/2022]
|
15
|
MR Venography of Deep Veins: Changes with Uterine Fibroid Embolization. Cardiovasc Intervent Radiol 2008; 32:284-8. [DOI: 10.1007/s00270-008-9466-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2008] [Accepted: 07/22/2008] [Indexed: 11/26/2022]
|
16
|
Lim RP, Hecht EM, Xu J, Babb JS, Oesingmann N, Wong S, Muhs BE, Gagne P, Lee VS. 3D nongadolinium-enhanced ECG-gated MRA of the distal lower extremities: Preliminary clinical experience. J Magn Reson Imaging 2008; 28:181-9. [DOI: 10.1002/jmri.21416] [Citation(s) in RCA: 85] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
|
17
|
|
18
|
Diagnostic Performance of Gadobenate Dimeglumine–Enhanced MR Angiography of the Iliofemoral and Calf Arteries: A Large-Scale Multicenter Trial. AJR Am J Roentgenol 2007; 189:1223-37. [PMID: 17954665 DOI: 10.2214/ajr.07.2218] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
19
|
Magnetic Resonance Imaging. Vasc Med 2006. [DOI: 10.1016/b978-0-7216-0284-4.50017-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
20
|
Gjønnaess E, Morken B, Sandbaek G, Stranden E, Slagsvold CE, Jørgensen JJ, Nylaende M, Abdelnoor M, Dullerud R. Gadolinium-enhanced Magnetic Resonance Angiography, Colour Duplex and Digital Subtraction Angiography of the Lower Limb Arteries from the Aorta to the Tibio-peroneal Trunk in Patients with Intermittent Claudication. Eur J Vasc Endovasc Surg 2006; 31:53-8. [PMID: 16269254 DOI: 10.1016/j.ejvs.2005.09.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2005] [Accepted: 09/12/2005] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To evaluate the sensitivity, specificity, positive and negative predictive value of contrast-enhanced (gadolinium) magnetic resonance imaging (CE-MRA) and colour duplex ultrasound (CDU) of lower limb arteries. DESIGN Prospective, single centre study. MATERIAL AND METHODS A consecutive series of 58 patients with intermittent claudication (IC) were examined with CE-MRA and CDU from the infrarenal aorta to the tibio-peroneal trunk with digital subtraction angiography (DSA) as reference. The arterial tree was divided into 15 segments, pooled into three regions; suprainguinal, thigh and knee. Sensitivity, specificity, positive and negative predictive values for significant obstructions were calculated. Cohen Kappa statistics was used to establish agreement between the three methods. RESULTS The sensitivity (specificity in parentheses) for significant obstructions in the suprainguinal region were 96% (94%) for CE-MRA and 91% (96%) for CDU, in the thigh region 92% (95%) for CE-MRA and 76% (99%) for CDU, and in the knee region 93% (96%) for CE-MRA and 33% (98%) for CDU. CDU failed to visualize 10% of suprainguinal, 2% of thigh and 13% of knee-region arterial segments. CONCLUSIONS Both CE-MRA and CDU are good alternatives to DSA in the suprainguinal- and thigh-region. In the knee region only CE-MRA can be relied upon as an alternative to DSA. Imaging by CDU is not suited to situations were evaluation of runoff vessels is important.
Collapse
Affiliation(s)
- E Gjønnaess
- Department of Radiology, Aker University Hospital, Oslo, Norway.
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Rapp JH, Wolff SD, Quinn SF, Soto JA, Meranze SG, Muluk S, Blebea J, Johnson SP, Rofsky NM, Duerinckx A, Foster GS, Kent KC, Moneta G, Middlebrook MR, Narra VR, Toombs BD, Pollak J, Yucel EK, Shamsi K, Weisskoff RM. Aortoiliac Occlusive Disease in Patients with Known or Suspected Peripheral Vascular Disease: Safety and Efficacy of Gadofosveset-enhanced MR Angiography—Multicenter Comparative Phase III Study. Radiology 2005; 236:71-8. [PMID: 15987963 DOI: 10.1148/radiol.2361040148] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively determine the safety and efficacy of the gadolinium-based blood pool magnetic resonance (MR) imaging contrast agent gadofosveset in patients known to have or suspected of having peripheral vascular disease. MATERIALS AND METHODS Ethical committee approval and patient written informed consent were obtained. This study was compliant with the Health Insurance Portability and Accountability Act. Adults known or suspected to have peripheral vascular disease received gadofosveset (0.03 mmol per kilogram of body weight) for MR angiography of the aortoiliac region. Gadofosveset-enhanced MR angiography and unenhanced two-dimensional time-of-flight MR angiography were compared with the reference standard, conventional angiography, for the presence of vascular stenosis. All patients were monitored for adverse events with hematologic analysis, analysis of blood chemistry, urinalysis, and electrocardiographic parameters; these methods were analyzed to determine safety. RESULTS A total of 274 patients were enrolled at 37 centers. Gadofosveset-enhanced MR angiography showed significant improvement (P < .001) compared with unenhanced MR angiography for each of the readers for diagnosis of clinically significant (> or = 50%) stenosis. Specificity and accuracy were significantly greater for three readers, and sensitivity increased significantly for two readers. For all readers, the area under the receiver operator characteristic curve for both quantitative and qualitative measures of significant disease increased (P < .001) for gadofosveset-enhanced MR angiography versus two-dimensional time-of-flight MR angiography. All readers also expressed more confidence in diagnosis (P < .001) and found fewer images to be uninterpretable (0.5% vs 11.0%). The most common adverse events were as follows: feeling hot, 12 (4.4%) patients; nausea, 10 (3.6%) patients; headache, nine (3.3%) patients; and burning sensation, eight (2.9%) patients. Only four serious adverse events were reported, in three patients, and all events were rated as unlikely related to the drug. No patients were excluded because of adverse events or laboratory abnormalities. There were no clinically important trends in the findings of hematologic analysis, blood chemistry, urinalysis, electrocardiography, or physical examination. CONCLUSION On the basis of substantial improvements over non-contrast MR angiography in efficacy and a minimal and transient side-effect profile, gadofosveset was found to be safe and effective for MR angiography in patients known or suspected to have peripheral vascular disease.
Collapse
Affiliation(s)
- Joseph H Rapp
- Surgical Service (112G San Francisco DVA Medical Center, 4150 Clement St, San Francisco, CA 94121, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Janka R, Fellner C, Wenkel E, Lang W, Bautz W, Fellner FA. Contrast-enhanced MR Angiography of Peripheral Arteries including Pedal Vessels at 1.0 T: Feasibility Study with Dedicated Peripheral Angiography Coil. Radiology 2005; 235:319-26. [PMID: 15731370 DOI: 10.1148/radiol.2351031987] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively determine feasibility of contrast material-enhanced magnetic resonance (MR) angiography of the peripheral arteries from distal aorta to pedal arteries with a 1.0-T system and a dedicated phased-array coil. MATERIALS AND METHODS Twenty-seven patients with peripheral arteriosclerotic occlusive disease underwent contrast-enhanced MR angiography with an automatic moving-table technique. In addition, lower-leg and pedal arteries were examined without table movement (hybrid technique). Two radiologists independently reviewed MR angiograms to assess image quality and grade stenosis in 13 segments per leg. Each was blinded to patients' clinical data. Twenty-five of the patients also underwent conventional angiography. Stenosis grade at conventional angiography was assessed by two radiologists in consensus. Interobserver variability for stenosis grade at MR angiography was calculated with Cohen kappa test. Specificity and sensitivity of MR angiography in detection of stenosis of more than 50% and occlusion were calculated for both observers. The study was approved by the local ethics committee. RESULTS In 14 of the 27 patients, hybrid technique was superior to moving-table technique because there was less venous overlap (11 patients), fewer motion artifacts (one patient), or both (two patients). In nine patients, there was no difference between techniques; in four patients, moving-table technique was superior. Stenosis grade was analyzed in 698 segments with MR angiography and in 638 segments with both conventional and MR angiography. Kappa analysis of interobserver agreement with MR angiography yielded a score of 0.84. For the 638 segments evaluated with both conventional and MR angiography, observers 1 and 2 assigned same grade of stenosis with both modalities in 558 and 555 segments, respectively. Sensitivity for stenoses greater than 50% and occlusion was 94.4% and 91.1% for observers 1 and 2, respectively, and specificity was 90.6% and 91.3%. More distal runoff vessels were shown with MR angiography in seven cases and with conventional angiography in two cases. CONCLUSION Contrast-enhanced MR angiography of the peripheral vessels with a 1.0-T system and dedicated peripheral angiography coil is feasible, and in some cases, it provides additional information compared with conventional angiography.
Collapse
Affiliation(s)
- Rolf Janka
- Institute of Diagnostic Radiology, Friedrich-Alexander-University Erlangen-Nürnberg, Maximiliansplatz 1, D-91054 Erlangen, Germany.
| | | | | | | | | | | |
Collapse
|
23
|
Affiliation(s)
- James F M Meaney
- Department of Diagnostic Imaging, St. James's Hospital, James's Street, Dublin 8, Ireland.
| | | |
Collapse
|
24
|
Peripheral MR angiography. Magn Reson Imaging Clin N Am 2004. [DOI: 10.1016/j.mric.2004.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
25
|
Carles Vilanova J, Barceló J, Capdevila A, Lluís Dolz J, Villalón M. Angio-RM en el sistema osteomuscular. RADIOLOGIA 2004. [DOI: 10.1016/s0033-8338(04)77987-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
26
|
Montgomery ML, Case RS. Magnetic resonance imaging of the vascular system: a practical approach for the radiologist. Top Magn Reson Imaging 2003; 14:376-85. [PMID: 14625466 DOI: 10.1097/00002142-200310000-00004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Contrast-enhanced magnetic resonance angiography (CE-MRA) has benefited from rapid technologic developments, including specific hardware and pulse sequence design. This article provides a brief practical overview of technique together with clinical examples of utility in daily application, from the view of an interventional radiologist. CE-MRA is rapidly replacing catheter-based diagnostic angiography for examination of the carotid arteries, aorta, renal arteries, and lower extremity.
Collapse
Affiliation(s)
- Mark L Montgomery
- Department of Radiology, Scott & White Clinic and Hospital, Temple, Texas 76508, USA.
| | | |
Collapse
|
27
|
Perreault P, Edelman MA, Baum RA, Yucel EK, Weisskoff RM, Shamsi K, Mohler ER. MR angiography with gadofosveset trisodium for peripheral vascular disease: phase II trial. Radiology 2003; 229:811-20. [PMID: 14593194 DOI: 10.1148/radiol.2293021180] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate the dose response and safety of gadofosveset trisodium-enhanced magnetic resonance (MR) angiography compared with nonenhanced two-dimensional time-of-flight MR angiography and with x-ray angiography as the standard. MATERIALS AND METHODS In this randomized, 20-center, double-blind study, 238 men and women who had peripheral vascular disease or were suspected of having it received intravenous injection of placebo or gadofosveset (0.005, 0.01, 0.03, 0.05, or 0.07 mmol per kilogram of body weight). MR angiographic images were evaluated by three blinded readers, and x-ray angiographic images were evaluated by two readers. Hypothesis testing for the presence of a dose response was based on a linear test for trend for increase in area under the receiver operating characteristic curve as a function of dose for each reader of MR angiographic images independently. RESULTS Gadofosveset administration resulted in a dose-dependent increase in diagnostic accuracy for detection of aortoiliac occlusive disease as reflected in the area under the receiver operating characteristic curve for each reader (P <.001). The plateau in effectiveness improvement began at the 0.03 mmol/kg dose. At doses of 0.03 mmol/kg and higher, gadofosveset-enhanced MR angiography provided an approximate 20% increase in accuracy over nonenhanced MR angiography for diagnosis of clinically significant aortoiliac occlusive disease. Gadofosveset exhibited a good safety profile in all dose groups. Three serious adverse events were possibly or probably related to gadofosveset administration. There were no dose-related trends in severe or serious adverse events in patients receiving gadofosveset. CONCLUSION A dose of 0.03 mmol/kg of gadofosveset was safe and effective for evaluation of aortoiliac occlusive disease with MR angiography.
Collapse
Affiliation(s)
- Pierre Perreault
- Department of Radiology, CHUM-Hospital St Luc, Montreal, Quebec, Canada
| | | | | | | | | | | | | |
Collapse
|
28
|
Hentsch A, Aschauer MA, Balzer JO, Brossmann J, Busch HP, Davis K, Douek P, Ebner F, van Engelshoven JMA, Gregor M, Kersting C, Knüsel PR, Leen E, Leiner T, Loewe C, McPherson S, Reimer P, Schäfer FKW, Taupitz M, Thurnher SA, Tombach B, Wegener R, Weishaupt D, Meaney JFM. Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: a prospective, multi-centre blinded comparison with digital subtraction angiography. Eur Radiol 2003; 13:2103-14. [PMID: 12928960 DOI: 10.1007/s00330-003-1844-5] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2002] [Revised: 12/09/2002] [Accepted: 01/21/2003] [Indexed: 10/26/2022]
Abstract
The purpose of this study was to compare moving-table three-dimensional contrast-enhanced magnetic resonance angiography (CE MRA), using 1.0-mol gadobutrol, with intra-arterial digital subtraction angiography (i.a. DSA) for evaluation of pelvic and peripheral arteries in patients with peripheral arterial occlusive disease. A total of 203 patients were examined in a prospective, multi-centre study at 1.0/1.5 T. Ten vessel segments of one leg were evaluated on-site and by three independent blinded reviewers off-site. One hundred eighty-two patients were evaluable in blinded reading. For pelvis and thigh, there was statistically significant diagnostic agreement between CE MRA and i.a. DSA on-site (94%) and off-site (86-88%). Overall, for detection of clinically significant stenoses, 93% sensitivity and 90% specificity were achieved in on-site evaluation, with 71-76 and 87-93% off-site; for detection of occlusion, sensitivity and specificity on-site were 91 and 97%, with 75-82 and 94-98% off-site. Evaluation was more sensitive on-site than off-site for detection of stenoses and occlusion, whereas specificity was similar. The CE MRA with 1.0-mol gadobutrol gave results comparable to those of i.a. DSA for the larger arteries of pelvis and thigh. Results for calf arteries were compromised by spatial resolution and technical limitations.
Collapse
|
29
|
Loewe C, Cejna M, Schoder M, Loewe-Grgurin M, Wolf F, Lammer J, Thurnher SA. Contrast Material–enhanced, Moving-Table MR Angiography versus Digital Subtraction Angiography for Surveillance of Peripheral Arterial Bypass Grafts. J Vasc Interv Radiol 2003; 14:1129-37. [PMID: 14514804 DOI: 10.1016/s1051-0443(07)60526-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
PURPOSE To assess the accuracy of moving-table MR angiography (MRA) in the evaluation of peripheral bypass grafts. MATERIALS AND METHODS There were 39 patients who had had peripheral bypass graft surgery and then subsequently underwent digital subtraction angiography (DSA) and contrast material-enhanced MRA, which was performed with moving-table software on a 1.0-T system before and during administration of 40 mL gadolinium. For evaluation, every bypass graft was divided into three parts and every leg into 14 segments. Disease severity was scored in four categories (0%-29%, 30%-69%, 70%-99%, 100%). Results were compared with those of the DSA. A total of 147 bypass graft segments and 938 vessel segments were classified. RESULTS In 132 of the assessable 147 bypass segments, disease gradings with both methods were congruent; however, 13 stenoses were misinterpreted by MRA for one grade and two additional lesions by two grades, leading to an accuracy in precise stenoses detection of 89.9%. The sensitivity and specificity values in the detection of bypass graft stenoses >69% (grade 3 + 4 lesions) reached 90.0% and 98.3%, respectively. In 821 of 938 vessel segments the accuracy of MRA in stenoses detection reached 87.5%. The sensitivity and specificity values in the detection of grade 3 + 4 lesions were 95.6% and 94.0% for the native vessels, respectively. CONCLUSION Moving-table MRA was as accurate in assessing bypass grafts as it was for the native arteries and showed a great accuracy in stenosis detection compared with DSA. Therefore, MRA is a promising modality for bypass graft surveillance and might be a noninvasive alternative to DSA in this regard.
Collapse
Affiliation(s)
- Christian Loewe
- Section of Angiography and Interventional Radiology, Department of Radiology, University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria.
| | | | | | | | | | | | | |
Collapse
|
30
|
Abstract
Peripheral arterial occlusive disease is a chronic and progressive disease with a reported incidence rate from 4.5% to 8.8% in men over 55 years of age. The diagnosis is usually made clinically, but for treatment planning and control, imaging of the peripheral arteries is required. Since its introduction in 1994, contrast-enhanced MR angiography has demonstrated a high diagnostic confidence and has replaced the invasive intra-arterial DSA, which is still the current gold standard for many different indications. For the peripheral arteries, clinical use of MR angiography was hampered for some years by the unsolved problem of the large imaging volume and the small diameter of the distal arteries. However, since the availability of ultra-fast high-gradient sequences and the possibility of moving-bed imaging, contrast-enhanced MR angiography, over the last few years, has shown its enormous potential and high accuracy in the diagnosis and follow-up of patients suffering from peripheral arterial occlusive disease. Exciting innovations in hardware and software allows very fast, very accurate, and very robust noninvasive imaging of the peripheral arteries, and both treatment planning as well as follow-up can be performed using contrast-enhanced MR angiography. The following review introduces the basic concepts of peripheral MR angiography--focusing on contrast enhanced imaging--and presents the different techniques as well as some potential limitations and how they could be solved. Finally, this article provides a look into the already-begun future of peripheral contrast-enhanced MR angiography with hybrid and combination techniques.
Collapse
Affiliation(s)
- Christian Loewe
- Department of Radiology, Section of Angiography and Interventional Radiology, University of Vienna, Vienna, Austria.
| |
Collapse
|
31
|
Visser K, Kock MCJM, Kuntz KM, Donaldson MC, Gazelle GS, Hunink MGM. Cost-effectiveness targets for multi-detector row CT angiography in the work-up of patients with intermittent claudication. Radiology 2003; 227:647-56. [PMID: 12773672 DOI: 10.1148/radiol.2273020441] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To determine the costs, sensitivity for detection of significant stenoses, and proportion of equivocal multi-detector row computed tomographic (CT) angiography results in the work-up of patients with intermittent claudication that would make this imaging examination cost-effective compared with gadolinium-enhanced magnetic resonance (MR) angiography. MATERIALS AND METHODS A decision model was used to compare the societal cost-effectiveness of a new imaging modality with that of gadolinium-enhanced MR angiography. Main outcome measures were quality-adjusted life years (QALYs) and lifetime costs. By using threshold analysis of a given willingness to pay per QALY, target values for costs, sensitivity for detection of significant stenoses, and proportion of cases requiring additional work-up with intraarterial digital subtraction angiography owing to equivocal results of the new modality were determined. The base case evaluated was that of 60-year-old men with severe intermittent claudication and assumed an incremental cost-effectiveness threshold of 100,000 US dollars per QALY. RESULTS If treatment were limited to angioplasty, a new imaging modality would be cost-effective if the costs were 300 US dollars and the sensitivity was 85%, even if up to 35% of patients needed additional work-up. When both angioplasty and bypass surgery were considered as treatment options, a new imaging modality was cost-effective if the costs were 300 US dollars, the sensitivity was higher than 94%, and 20% of patients required additional work-up. CONCLUSION Multi-detector row CT angiography, as compared with currently used imaging modalities such as MR angiography, has the potential to be cost-effective in the evaluation of patients with intermittent claudication.
Collapse
Affiliation(s)
- Karen Visser
- Program for the Assessment of Radiological Technology, Department of Epidemiology and Biostatistics, Erasmus MC, University Medical Center Rotterdam, Dr Molewaterplein 50, Rm Ee21-40B, 3015GE Rotterdam, The Netherlands.
| | | | | | | | | | | |
Collapse
|
32
|
Abstract
Contrast-enhanced MRA can be an accurate and reliable method for the arterial evaluation of the abdominal aorta and peripheral vessels. This technique can be adapted for a variety of anatomic regions. The basic issues relate to proper synchronization of imaging with peak arterial enhancement and to optimization of voxel dimensions for adequate depiction of the arterial structures.
Collapse
Affiliation(s)
- Vincent B Ho
- Department of Radiology, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20814, USA.
| | | |
Collapse
|
33
|
Loewe C, Schoder M, Rand T, Hoffmann U, Sailer J, Kos T, Lammer J, Thurnher S. Peripheral vascular occlusive disease: evaluation with contrast-enhanced moving-bed MR angiography versus digital subtraction angiography in 106 patients. AJR Am J Roentgenol 2002; 179:1013-21. [PMID: 12239057 DOI: 10.2214/ajr.179.4.1791013] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
OBJECTIVE The purpose of our study was to compare contrast-enhanced moving-bed MR angiography and digital subtraction angiography in the evaluation of peripheral vascular occlusive disease. MATERIALS AND METHODS This retrospective report includes 106 patients (45 women, 61 men) with known or suspected peripheral vascular occlusive disease who underwent MR angiography and intraarterial digital subtraction angiography of the peripheral arteries. MR angiography was performed on a 1.0-T unit using a moving-bed technique. Every leg was divided into 14 vascular segments, and severity of disease was scored in four categories. Digital subtraction angiography was the standard of reference. RESULTS In the 106 patients, 2378 vessel segments were evaluated with both imaging modalities. In 2156 segments, MR angiography and digital subtraction angiography were concordant for stenosis classification, in 188 segments the two modalities differed in one category, and in 24 segments they differed in two categories. MR angiography achieved sensitivity and specificity of 96.7% and 95.8%, respectively, for differentiating nonsignificant from hemodynamically significant stenosis (kappa = 0.91). CONCLUSION This study indicates that MR angiography is an accurate imaging modality in clinical practice. Our data support the concept that MR angiography can modify the diagnosis of suspected peripheral vascular occlusive disease.
Collapse
Affiliation(s)
- Christian Loewe
- Department of Radiology, Section of Angiography and Interventional Radiology, University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | | | | | | | | | | | | | | |
Collapse
|
34
|
Hood MN, Ho VB, Foo TKF, Marcos HB, Hess SL, Choyke PL. High-resolution gadolinium-enhanced 3D MRA of the infrapopliteal arteries. Lessons for improving bolus-chase peripheral MRA. Magn Reson Imaging 2002; 20:543-9. [PMID: 12413600 DOI: 10.1016/s0730-725x(02)00531-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Peripheral magnetic resonance angiography (MRA) is growing in use. However, methods of performing peripheral MRA vary widely and continue to be optimized, especially for improvement in illustration of infrapopliteal arteries. The main purpose of this project was to identify imaging factors that can improve arterial visualization in the lower leg using bolus chase peripheral MRA. Eighteen healthy adults were imaged on a 1.5T MR scanner. The calf was imaged using conventional three-station bolus chase three-dimensional (3D) MRA, two dimensional (2D) time-of-flight (TOF) MRA and single-station Gadolinium (Gd)-enhanced 3D MRA. Observer comparisons of vessel visualization, signal to noise ratios (SNR), contrast to noise ratios (CNR) and spatial resolution comparisons were performed. Arterial SNR and CNR were similar for all three techniques. However, arterial visualization was dramatically improved on dedicated, arterial-phase Gd-enhanced 3D MRA compared with the multi-station bolus chase MRA and 2D TOF MRA. This improvement was related to optimization of Gd-enhanced 3D MRA parameters (fast injection rate of 2 mL/sec, high spatial resolution imaging, the use of dedicated phased array coils, elliptical centric k-space sampling and accurate arterial phase timing for image acquisition). The visualization of the infrapopliteal arteries can be substantially improved in bolus chase peripheral MRA if voxel size, contrast delivery, and central k-space data acquisition for arterial enhancement are optimized. Improvements in peripheral MRA should be directed at these parameters.
Collapse
Affiliation(s)
- Maureen N Hood
- Department of Radiology, Uniformed Services University of the Health Sciences, Bethesda, MD 20814-4799, USA.
| | | | | | | | | | | |
Collapse
|
35
|
Gregor M, Tombach B, Hentsch A, Reimer P. Peripheral run-off CE-MRA with a 1.0 molar gadolinium chelate (Gadovist) with intraarterial DSA comparison. Acad Radiol 2002; 9 Suppl 2:S398-400. [PMID: 12188288 DOI: 10.1016/s1076-6332(03)80243-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Affiliation(s)
- M Gregor
- Department of Radiology, Karlsruhe City Hospital, Städtisches Klinikum Karlsruhe, Germany
| | | | | | | |
Collapse
|
36
|
Yoo SK, Watts R, Winchester PA, Zabih R, Wang Y, Prince MR. Postprocessing techniques for time-resolved contrast-enhanced MR angiography. Radiology 2002; 222:564-8. [PMID: 11818629 DOI: 10.1148/radiol.2222010608] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The purpose of this study was to improve dynamic two-dimensional projection magnetic resonance digital subtraction angiography by using remasking and filtering postprocessing techniques. Four methods were evaluated in 50 patients: default mask subtraction, remasked subtraction, filtering based on the SD, and linear filtering. The results demonstrated that postprocessing techniques such as linear filtering can reduce background motion artifacts and improve arterial contrast-to-noise ratio.
Collapse
Affiliation(s)
- Stanley K Yoo
- Department of Radiology MR Research, Weill Medical College of Cornell University, 515 E 71st St, Suite S120, New York, NY 10021. Received March 14, 2001
| | | | | | | | | | | |
Collapse
|
37
|
Eiberg JP, Lundorf E, Thomsen C, Schroeder TV. Peripheral vascular surgery and magnetic resonance arteriography--a review. Eur J Vasc Endovasc Surg 2001; 22:396-402. [PMID: 11735175 DOI: 10.1053/ejvs.2001.1503] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVES to review the current status of lower limb MRA. DESIGN a literature review based predominantly on a MEDLINE database search of English-language publications from January 1991 to October 2000. MATERIALS AND METHODS twenty-eight articles, concerning non-enhanced MRA (13), gadolinium-enhanced MRA (14) or both (1), met the predefined requirement for quality. Results gadolinium-enhanced MRA (CE-MRA) seems to be more accurate, quicker and associated with fewer problems than non-enhanced (TOF) MRA. TOF-MRA has a sensitivity and specificity of 93% (range 64-100%) and 88% (range 57-100%) respectively, and CE-MRA presents values of 96% (range 71-100%) and 96% (63-100%), respectively, using conventional arteriography as the gold standard. Some articles report a substantial incidence of runoff vessels suitable for distal bypass visible on MRA but invisible on conventional arteriography. Gadolinium contrast is given intravenously and is generally well tolerated and has no known nephrotoxicity. CONCLUSION CE-MRA is accurate compared to conventional arteriography, has the potential to increase the limb salvage rate for selected patients, is non-invasive and well tolerated.
Collapse
Affiliation(s)
- J P Eiberg
- Department of Vascular Surgery RK, Rigshospitalet 3111, University of Copenhagen, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
| | | | | | | |
Collapse
|
38
|
Juergens KU, Tombach B, Reimer P, Vestring T, Heindel W. Three-dimensional contrast-enhanced MR angiography of endovascular covered stents in patients with peripheral arterial occlusive disease. AJR Am J Roentgenol 2001; 176:1299-303. [PMID: 11312198 DOI: 10.2214/ajr.176.5.1761299] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Three-dimensional contrast-enhanced MR angiography was performed to study MR characteristics of Hemobahn devices. MATERIALS AND METHODS Changes in endoluminal signal intensities and the precision of the endoluminal diameter measurement were investigated in phantom studies for different concentrations of gadopentetate dimeglumine. Before and after the Hemobahn devices had been implanted, 10 patients with peripheral arterial occlusive disease were examined on MR imaging and three-dimensional contrast-enhanced MR angiography. RESULTS Phantom experiments using three-dimensional MR angiography showed stent-related signal void as a dark ring in the axial image orientation, providing a precise delineation of the stent--vessel border (mean endoluminal diameter, 8.2 mm; SD, 0.6 mm). Changes in endoluminal signal intensity were evaluated quantitatively. Stent-related artifacts did not compromise diagnostic imaging quality. All Hemobahn devices were found to be patent without migration of an implanted graft. In one patient, an extensive perigraft reaction (edema and contrast-enhanced perivascular tissue) was postinterventionally detected on MR imaging and corresponded to clinically evident postimplantation symptoms. CONCLUSION Three-dimensional contrast-enhanced MR angiography is a suitable tool to follow up the implantation of Hemobahn devices and to detect intra- and extraluminal abnormalities.
Collapse
Affiliation(s)
- K U Juergens
- Department of Clinical Radiology, University of Muenster, Albert-Schweitzer-Str. 33, D-48129 Muenster, Germany
| | | | | | | | | |
Collapse
|
39
|
Ruehm SG, Goyen M, Barkhausen J, Kröger K, Bosk S, Ladd ME, Debatin JF. Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet 2001; 357:1086-91. [PMID: 11297960 DOI: 10.1016/s0140-6736(00)04261-6] [Citation(s) in RCA: 133] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND Choice of treatment for atherosclerosis depends on various clinical factors and radiological techniques. We aimed to assess the diagnostic accuracy of a new three-dimensional magnetic resonance angiography (3D MRA) strategy for the display of arterial vasculature from supra-aortic arteries to distal runoff vessels in 72 s. METHODS We examined five healthy volunteers and six patients over 6 weeks. Conventional digital subtraction angiography (DSA) was available as reference standard in all six patients. Magnetic resonance imaging was done on a commercially available 1.5 Tesla scanner. The imaging technique was based on the acquisition of five 3D data sets in rapid succession with an optimum single injection protocol. FINDINGS Compared with conventional catheter angiography, according to the findings of two independent and masked readers, whole-body MRA had overall sensitivities of 91% (95% CI 0.76-0.98) and 94% (0.8-0.99), and specificities of 93% (0.85-0.97) and 90% (0.82-0.96) for the detection of substantial vascular disease (luminal narrowing >50%), interobserver agreement for assessment of whole-body magnetic angiograms was very good (kappa=0.94; 95% CI 0.9-0.98). INTERPRETATION The technique provides a comprehensive non-invasive approach for morphological screening assessment of the arterial vasculature from supra-aortic arteries to the distal runoff arteries.
Collapse
Affiliation(s)
- S G Ruehm
- Department of Diagnostic Radiology, University Hospital Essen, Germany.
| | | | | | | | | | | | | |
Collapse
|
40
|
Ruehm SG, Nanz D, Baumann A, Schmid M, Debatin JF. 3D contrast-enhanced MR angiography of the run-off vessels: value of image subtraction. J Magn Reson Imaging 2001; 13:402-11. [PMID: 11241814 DOI: 10.1002/jmri.1058] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
The diagnostic gain associated with image subtractions was assessed regarding contrast-enhanced 3D magnetic resonance angiography (MRA) image sets of the pelvic and lower extremity arteries. The MRA strategy combined a dedicated vascular coil with a single injection, two-station protocol. Voxel-by-voxel signal intensity subtraction was performed on MRA image sets obtained before and during dynamic infusion of a para-magnetic contrast agent. Non-subtracted and subtracted MRA image sets were assessed for the presence of occlusive (four grades) disease, using DSA as the standard of reference. In addition, SNR and CNR were recorded for each vascular segment on both the non-subtracted and subtracted images. While CNR values of subtracted images exceeded those of non-subtracted images (P < 0.05), there was no difference in diagnostic performance. For the detection of hemodynamically significant disease, non-subtracted and subtracted MRA provided overall sensitivity and specificity of 90.2%/90.3% and 95.1%/95.6%, respectively. Concordance between non-subtracted and subtracted MRA was excellent (Kappa = 0.86).
Collapse
Affiliation(s)
- S G Ruehm
- Department of Diagnostic Radiology, University Hospital Essen, Essen Germany
| | | | | | | | | |
Collapse
|
41
|
Reid SK, Pagan-Marin HR, Menzoian JO, Woodson J, Yucel EK. Contrast-enhanced moving-table MR angiography: prospective comparison to catheter arteriography for treatment planning in peripheral arterial occlusive disease. J Vasc Interv Radiol 2001; 12:45-53. [PMID: 11200353 DOI: 10.1016/s1051-0443(07)61401-8] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
PURPOSE Prospective comparison of contrast-enhanced moving-table magnetic resonance (MR) angiography to catheter arteriography in endovascular and surgical treatment planning in patients with peripheral arterial occlusive disease. MATERIALS AND METHODS Thirteen patients scheduled for catheter arteriography for lower extremity arterial occlusive disease underwent contrast-enhanced moving-table MR angiography immediately prior to arteriography. A treatment plan was determined by the vascular surgeon, based on MR angiography, who was blinded to the catheter arteriogram. The treatment plan determined by the MR angiogram was compared to the final treatment plan, which was based on the catheter arteriogram and intraluminal pressure measurements. RESULTS Treatment plans based on MR angiography and catheter arteriography were identical in 10 of 13 patients (71%). For identifying lesions resulting in intervention, MR angiography had sensitivity of 100% and a positive predictive value of 92%. MR angiography had a treatment specific predictive value of 88% for each lesion identified, and 95% for lesions identified in patients evaluated for claudication. If treatment plans were based on MR angiography only, 46% of patients would have avoided catheter arteriography. CONCLUSION Contrast-enhanced moving-table MR angiography may be an effective alternative to catheter arteriography in endovascular and surgical treatment planning in selected patients with peripheral arterial occlusive disease, but larger studies are necessary to confirm this.
Collapse
Affiliation(s)
- S K Reid
- Department of Radiology, Boston University Medical Center, Massachusetts 02118, USA.
| | | | | | | | | |
Collapse
|
42
|
Huber A, Heuck A, Baur A, Helmberger T, Waggershauser T, Billing A, Heiss M, Petsch R, Reiser M. Dynamic contrast-enhanced MR angiography from the distal aorta to the ankle joint with a step-by-step technique. AJR Am J Roentgenol 2000; 175:1291-8. [PMID: 11044026 DOI: 10.2214/ajr.175.5.1751291] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The aim of this study was to visualize the arteries from the distal aorta to the ankle joint and to determine the accuracy of MR angiography for detecting stenoses and occlusions. SUBJECTS AND METHODS Twenty-four patients with peripheral arterial occlusive disease underwent digital subtraction angiography and were examined on a 1.5-T MR scanner. The transit time for contrast material was determined with a test bolus injection. A T1-weighted three-dimensional gradient-echo sequence with short TR and TE was used for a dynamic measurement at the level of the iliac arteries, the upper leg, and the lower leg arteries. For each level a single dose of gadolinium was injected into an antecubital vein with an MR power injector. Maximal-intensity-projection reconstructions were calculated after subtraction of the first measurement at each level. Two experienced MR radiologists who were unaware of the digital subtraction angiography results interactively evaluated both the MIP reconstructions and the single slices on a workstation, first independently and then in a consensus interpretation. RESULTS With digital subtraction angiography, 80 hemodynamically significant stenoses and 39 occlusions were detected. For the stenoses and occlusions, a sensitivity of 100% was found for MR angiography. The specificity for the assessment of stenoses and occlusions was 98% and 94%, respectively, for the iliac arteries; 98% and 94%, respectively, for the upper leg arteries; and 94% and 95%, respectively, for the lower leg arteries. Most false-positive findings of occlusion were due to metal stents present in the iliac (n = 3) and upper leg (n = 4) arteries. CONCLUSION The MR imaging technique that we used revealed the arteries from the distal aorta to the ankle and proved to be reliable at showing arterial stenoses and occlusions.
Collapse
Affiliation(s)
- A Huber
- Department of Clinical Radiology, Klinikum der LMU, Grobetahadern, Marchioninistr. 15, 81377 München, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Nelemans PJ, Leiner T, de Vet HC, van Engelshoven JM. Peripheral arterial disease: meta-analysis of the diagnostic performance of MR angiography. Radiology 2000; 217:105-14. [PMID: 11012430 DOI: 10.1148/radiology.217.1.r00oc11105] [Citation(s) in RCA: 170] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To summarize the overall diagnostic performance of magnetic resonance (MR) angiography in the evaluation of peripheral arteriosclerotic occlusive disease and to identify the most important sources of variation in diagnostic accuracy between studies. MATERIALS AND METHODS A search strategy in MEDLINE and citation tracking were used to identify relevant English-language articles published since 1991. Each article was critically appraised for examination, patient, and study design characteristics. The accuracy data from different studies were analyzed by constructing summary receiver operating characteristic curves; multiple linear regression was used to examine the variation between study results. RESULTS Twenty-three studies were included. There was much heterogeneity in the study results, which could not be explained as differences in the threshold for a positive result. About half of the variation was due to the type of MR angiographic examination and the extent of image evaluation. The relative diagnostic odds ratio (DOR) for three-dimensional (3D) gadolinium-enhanced MR angiography compared with two-dimensional (2D) time-of-flight MR angiography was 7.46 (95% CI: 2.48, 22.20). The relative DOR for review of transverse source images or multiplanar reformations in addition to maximum intensity projections (MIPs) compared with the use of only MIPs for image evaluation was 4.53 (95% CI: 1.46, 13.87). CONCLUSION The diagnostic accuracy of 3D gadolinium-enhanced MR angiography is superior to that of 2D time-of-flight MR angiography. Also, the review of transverse source images or use of additional postprocessing techniques, such as multiplanar reformation, results in significantly better diagnostic performance.
Collapse
Affiliation(s)
- P J Nelemans
- Departments of Epidemiology and Radiology, University of Maastricht, P Debyeplein 1, 6229 HA Maastricht, the Netherlands.
| | | | | | | |
Collapse
|
44
|
Mitsuzaki K, Yamashita Y, Sakaguchi T, Ogata I, Takahashi M, Hiai Y. Abdomen, pelvis, and extremities: diagnostic accuracy of dynamic contrast-enhanced turbo MR angiography compared with conventional angiography-initial experience. Radiology 2000; 216:909-15. [PMID: 10966731 DOI: 10.1148/radiology.216.3.r00se25909] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
To determine the value of contrast material-enhanced three-dimensional turbo magnetic resonance (MR) angiography compared with conventional cut-film or digital subtraction angiography for evaluating arterial stenosis in the abdomen, pelvis, and extremities. For detection of significant stenosis, MR angiography had 91% sensitivity and 89% specificity. This technique is highly sensitive in lesion detection, but stenosis tended to be overestimated.
Collapse
Affiliation(s)
- K Mitsuzaki
- Department of Radiology, Kumamoto University School of Medicine, Honjo, Japan.
| | | | | | | | | | | |
Collapse
|
45
|
Swan JS, Kennell TW, Acher CW, Heisey DM, Grist TM, Korosec FR, Hagenauer ME. Magnetic resonance angiography of aorto-iliac disease. Am J Surg 2000; 180:6-12. [PMID: 11036131 DOI: 10.1016/s0002-9610(00)00412-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
BACKGROUND Four different techniques for aorto-iliac magnetic resonance angiography (MRA) were assessed for accuracy using a digital subtraction angiography (DSA) gold standard. Surgeons' confidence in their ability to generate treatment plans with MRA and DSA was assessed, in consultation with a radiologist. METHODS Two different two-dimensional (2D) time-of-flight (TOF) sequences, a phase-contrast sequence, and a contrast-enhanced (CE) MRA sequence were used. Receiver operating characteristic (ROC) curves were plotted and areas (A(z)) calculated from radiologists' readings. Surgeons' confidence in their ability to utilize the images for treatment planning was assessed with a 5-point Likert scale. Thirty-six patients were evaluated. RESULTS CE MRA had a sensitivity, specificity, and A(z) of.92,.93, and.96, respectively, for stenoses 50% or greater. CE MRA performed better than other sequences, but the improvement compared with gated 2D TOF was not statistically significant. Interobserver agreement for CE MRA and DSA yielded identical Kappa values. Surgeons were most confident in DSA, followed by CE MRA, which was significantly preferred to other techniques. CONCLUSIONS CE MRA closely approximates DSA in terms of diagnostic accuracy. Surgeons considering treatment plans are confident in the CE MRA technique, relative to other MRA methods.
Collapse
Affiliation(s)
- J S Swan
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | | | | | | | | | | |
Collapse
|
46
|
Bonk RT, Schmiedl UP, Yuan C, Nelson JA, Black CD, Ladd DL. Time-of-flight MR angiography with Gd-DTPA hexamethylene diamine co-polymer blood pool contrast agent: comparison of enhanced MRA and conventional angiography for arterial stenosis induced in rabbits. J Magn Reson Imaging 2000; 11:638-46. [PMID: 10862063 DOI: 10.1002/1522-2586(200006)11:6<638::aid-jmri10>3.0.co;2-g] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Vascular stenoses were induced in the external iliac arteries of New Zealand white rabbits by a combination of hypercholesterolemic diet and repeat balloon injury. Two-dimensional (2D) and three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) was performed with a specifically designed phased array coil in a 1.5 T system. Enhancement with gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) hexamethylene diamine co-polymer (Nycomed: NC 22181), a blood pool MR contrast agent, was measured after contrast administration and compared with pre-contrast images at the same levels. Vessel diameter measurements were obtained at multiple levels and compared with comparable levels on conventional angiograms of the same animals. Stable enhancement, averaging 227% above baseline, was observed with the 3D TOF MRA over the 40 minutes of this study. Enhancement was not observed with the 2D TOF technique. Measurement of the smallest vessels in this study with 3D TOF MRA was slightly improved following contrast enhancement, although both pre- and post-contrast diameter measurements tended to underestimate the assumed true vessel diameter. Thus, Gd-DTPA hexamethylene diamine co-polymer (Nycomed: NC 22181), a blood pool MR contrast agent, produces significant, stable enhancement with the 3D TOF technique and may improve MRA measurement of small vessels.
Collapse
Affiliation(s)
- R T Bonk
- Department of Radiology, University of Washington Medical Center, Seattle, Washington, 98195, USA
| | | | | | | | | | | |
Collapse
|
47
|
Ruehm SG, Hany TF, Pfammatter T, Schneider E, Ladd M, Debatin JF. Pelvic and lower extremity arterial imaging: diagnostic performance of three-dimensional contrast-enhanced MR angiography. AJR Am J Roentgenol 2000; 174:1127-35. [PMID: 10749264 DOI: 10.2214/ajr.174.4.1741127] [Citation(s) in RCA: 156] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The diagnostic performance of a three-dimensional MR angiography-based strategy was assessed with regard to its ability to characterize the arterial vasculature from the aortic bifurcation to the lower extremity runoff vessels. A single-injection, two-station protocol in combination with a lower-extremity vascular coil was used. SUBJECTS AND METHODS Both conventional digital subtraction angiography and three-dimensional contrast-enhanced MR angiography with a dedicated peripheral vascular coil were performed in 61 patients with suspected peripheral vascular disease. In a prospective analysis, one reviewer evaluated the digital subtraction angiographic images and a second reviewer evaluated the MR angiographic images; both were unaware of the results of the other imaging technique. Each vascular segment (29 segments per patient) was evaluated for the presence of occlusive vessel disease. The following grading system was applied: 0, normal; 1, vessel irregularity with a luminal reduction of less than 10%; 2, mild stenosis (lumen reduction, 10-49%); 3, severe stenosis (lumen reduction, 50-99%); and 4, occlusion (lumen reduction, 100%). In 11 patients surgical graft patency was assessed. RESULTS MR angiography provided an image quality comparable with that of digital subtraction angiography. Overall sensitivity and specificity for MR angiography were 92% and 96.6%, respectively, for the detection of hemodynamically significant disease and 92.3% and 99.4%, respectively, for the detection of occlusions. CONCLUSION Two-station contrast-enhanced three-dimensional MR angiography with a dedicated lower-extremity vascular coil proved effective enough to consider it as a noninvasive alternative to digital subtraction angiography in the assessment of the pelvic and lower extremity arterial vasculature.
Collapse
Affiliation(s)
- S G Ruehm
- Institute of Diagnostic Radiology, University Hospital Zurich, Switzerland
| | | | | | | | | | | |
Collapse
|
48
|
Abstract
Magnetic resonance (MR) angiography of lower extremity occlusive vascular disease has evolved into a feasible diagnostic imaging option. The previous emphasis on time-of-flight techniques was associated with lengthy acquisition times and artifactual signal losses. Those limitations presented an obstacle to widespread clinical implementation. However, the emergence of rapid imaging sequences combined with gadolinium chelate enhancement offers time-efficient alternatives that can yield a truer representation of the vascular anatomic structure. The technology is now poised to serve as a routine screening study, provided that radiologists understand all factors needed to generate clinically relevant MR angiograms. This article is intended to provide a useful resource directed toward achieving that understanding.
Collapse
Affiliation(s)
- N M Rofsky
- Department of Radiology, New York University Medical Center, MRI-Basement, Schwartz Bldg, 530 First Ave, New York, NY 10016, USA.
| | | |
Collapse
|
49
|
Abstract
Atherosclerotic involvement of the aorta and lower extremity vessels is a common clinical problem, especially in developed countries. While x-ray angiography has been the method of choice for preoperative evaluation of patients with atherosclerotic disease, magnetic resonance angiography (MRA) is emerging as a powerful noninvasive tool that is capable of providing information critical to the care of these patients. The objective of this manuscript is to review the current state-of-the-art of MRA of the abdominal aorta and lower extremity vessels. The techniques are described, the clinical indications for MRA are discussed, and the diagnostic accuracy and pitfalls of the various methods are presented.
Collapse
Affiliation(s)
- T M Grist
- Department of Radiology, University of Wisconsin-Madison, 53792-3252, USA.
| |
Collapse
|
50
|
Marchand B, Douek PC, Benderbous S, Corot C, Canet E. Pilot MR evaluation of pharmacokinetics and relaxivity of specific blood pool agents for MR angiography. Invest Radiol 2000; 35:41-9. [PMID: 10639035 DOI: 10.1097/00004424-200001000-00005] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
RATIONALE AND OBJECTIVES To evaluate the use of two new blood pool contrast agents (P760, P775) compared with a low-molecular-weight gadolinium chelate in MR angiography. METHODS The r1 efficiency of P760 was evaluated in vitro at 1.5 T; 3D abdominal contrast-enhanced MR angiography with qualitative analysis was compared in four rabbits after injection of incremental doses of P760 and in one rabbit after Gd-DOTA. A dynamic MR study was performed using a 2D T1-weighted turbo-flash MR sequence after injection of P760, P775, and Gd-DOTA. Each compound was tested at equivalent doses in three rabbits to assess r1 efficiency. Quantitative analysis of signal intensity in the aorta, the inferior vena cava, the renal cortex, and the medulla was performed. RESULTS In vitro, the r1 efficiency of P760 was 23.3 mmol(-1) x L x sec(-1) at 1.5 T. Injection of a dose of P760 10 times less than Gd-DOTA allowed similar vessel visualization. The signal intensity peak and first-pass contrast kinetics in the aorta and the inferior vena cava were similar with the three products. Compared with P760 and Gd-DOTA, P775 allowed a greater renal cortex signal intensity at the first pass and a faster decrease on delayed images. CONCLUSIONS The superior r1 efficiency of P760 and P775 was confirmed in vitro and in vivo at 1.5 T compared with Gd-DOTA, and P775 proved to be a rapid-clearance blood pool agent.
Collapse
|