1
|
Kravchenko D, Hagar MT, Vecsey‐Nagy M, Tremamunno G, Szilveszter B, Vattay B, Zsarnóczay E, Beke S, Maurovich‐Horvat P, Emrich T, Varga‐Szemes A. Value of Ultrahigh-Resolution Photon-Counting Detector Computed Tomography in Cardiac Imaging. Echocardiography 2025; 42:e70100. [PMID: 39945196 PMCID: PMC11822751 DOI: 10.1111/echo.70100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2024] [Revised: 01/27/2025] [Accepted: 01/31/2025] [Indexed: 02/16/2025] Open
Abstract
It was only fitting that when computed tomography (CT) was celebrating its 50th birthday since its maiden scan in 1971, it was also entering into a new generation in 2021 with the Food and Drug Administration's approval of the first photon-counting detector (PCD)-CT. As non-invasive cardiac imaging is evolving into an ever more important medical field, the introduction of this new technology promises a slew of improvements over energy-integrating detector (EID)-CTs, most importantly improved spatial resolution in the form of ultrahigh-resolution (UHR) imaging, reduced radiation exposure, and routinely acquired spectral information. Spatial resolution has historically been a key hurdle for cardiac CT, especially for coronary imaging where structures in the realm of 2 mm need to be assessed. Initial reports on the use of PCD-CT in cardiac imaging so far have been promising, but many questions ranging from standardized scan protocols to evidence-based recommendations remain. The aim of this review is to discuss the currently available literature regarding the use of UHR PCD-CT for cardiac imaging and explore if it has led to changes in guidelines or patient workflows.
Collapse
Affiliation(s)
- Dmitrij Kravchenko
- Department of Radiology and Radiological ScienceMedical University of South CarolinaCharlestonUSA
- Department of Diagnostic and Interventional RadiologyUniversity Hospital BonnBonnGermany
- Quantitative Imaging Lab Bonn (QILaB)University Hospital BonnBonnGermany
| | - Muhammad Taha Hagar
- Department of Radiology and Radiological ScienceMedical University of South CarolinaCharlestonUSA
- Department of Diagnostic and Interventional RadiologyMedical CentreFaculty of MedicineUniversity of FreiburgUniversity of FreiburgFreiburg im BreisgauGermany
| | - Milan Vecsey‐Nagy
- Department of Radiology and Radiological ScienceMedical University of South CarolinaCharlestonUSA
- Heart and Vascular CenterSemmelweis UniversityBudapestHungary
| | - Giuseppe Tremamunno
- Department of Radiology and Radiological ScienceMedical University of South CarolinaCharlestonUSA
- Department of Medical Surgical Sciences and Translational MedicineSapienza University of Rome – Radiology Unit – Sant'Andrea University HospitalRomeItaly
| | | | - Borbála Vattay
- Heart and Vascular CenterSemmelweis UniversityBudapestHungary
| | | | - Sámuel Beke
- Medical Imaging CenterSemmelweis UniversityBudapestHungary
| | | | - Tilman Emrich
- Department of Radiology and Radiological ScienceMedical University of South CarolinaCharlestonUSA
- Department of Diagnostic and Interventional RadiologyUniversity Medical Center of the Johannes Gutenberg‐UniversityMainzGermany
- German Centre for Cardiovascular ResearchPartner Site Rhine‐MainMainzGermany
| | - Akos Varga‐Szemes
- Department of Radiology and Radiological ScienceMedical University of South CarolinaCharlestonUSA
| |
Collapse
|
2
|
Gallo-Bernal S, Peña-Trujillo V, Gee MS. Dual-energy computed tomography: pediatric considerations. Pediatr Radiol 2024; 54:2112-2126. [PMID: 39470784 DOI: 10.1007/s00247-024-06074-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2024] [Revised: 10/07/2024] [Accepted: 10/08/2024] [Indexed: 11/01/2024]
Abstract
Multidetector computed tomography (CT) has revolutionized medicine and is now a fundamental aspect of modern radiology. Hardware and software advancements have significantly improved CT accessibility, image quality, and acquisition times. While considerable attention has been directed towards the potential risks of ionizing radiation from CT scans in children, recent concerns regarding the possible short- and long-term risks related to magnetic resonance imaging (MRI) conducted under general anesthesia have generated fresh interest in novel pediatric CT applications and techniques that allow imaging of awake patients at low radiation doses. Among these novel techniques, dual-energy CT (DECT) stands out for its ability to provide enhanced diagnostic information, reduce radiation doses further, and facilitate faster scans, making it a highly promising tool in pediatric radiology. This manuscript explores the current role of DECT in pediatric imaging, emphasizing its technical foundations, hardware configurations, and various reconstruction techniques. We discuss advanced post-processing techniques, such as material decomposition algorithms and virtual monoenergetic imaging, highlighting their clinical advantages in improving diagnostic accuracy and patient outcomes. Furthermore, the paper reviews the clinical applications of DECT in evaluating pulmonary perfusion, cardiovascular assessments, and oncologic imaging in pediatric patients.
Collapse
Affiliation(s)
- Sebastian Gallo-Bernal
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St., Austen 250, Boston, MA, 02114, USA
- Harvard University, Cambridge, MA, USA
- Pediatric Imaging Research Center (PIRC), Massachusetts General Hospital, Boston, MA, USA
| | - Valeria Peña-Trujillo
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St., Austen 250, Boston, MA, 02114, USA
- Harvard University, Cambridge, MA, USA
- Pediatric Imaging Research Center (PIRC), Massachusetts General Hospital, Boston, MA, USA
| | - Michael S Gee
- Department of Radiology, Massachusetts General Hospital, 55 Fruit St., Austen 250, Boston, MA, 02114, USA.
- Harvard University, Cambridge, MA, USA.
- Pediatric Imaging Research Center (PIRC), Massachusetts General Hospital, Boston, MA, USA.
| |
Collapse
|
3
|
Zhou W, Huo D, Browne LP, Zhou X, Weinman J. Universal 120-kV Dual-Source Ultra-High Pitch Protocol on the Photon-Counting CT System for Pediatric Abdomen of All Sizes: A Phantom Investigation Comparing With Energy-Integrating CT. Invest Radiol 2024; 59:719-726. [PMID: 38595181 DOI: 10.1097/rli.0000000000001080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
OBJECTIVES The purpose of this study is to determine if a universal 120-kV ultra-high pitch and virtual monoenergetic images (VMIs) protocol on the photon-counting computed tomography (PCCT) system can provide sufficient image quality for pediatric abdominal imaging, regardless of size, compared with protocols using a size-dependent kV and dual-source flash mode on the energy-integrating CT (EICT) system. MATERIALS AND METHODS One solid water insert and 3 iodine (2, 5, 10 mg I/mL) inserts were attached or inserted into phantoms of variable sizes, simulating the abdomens of a newborn, 5-year-old, 10-year-old, and adult-sized pediatric patients. Each phantom setting was scanned on an EICT using clinical size-specific kV dual-source protocols with a pitch of 3.0. The scans were performed with fixed scanning parameters, and the CTDI vol values of full dose were 0.30, 0.71, 1.05, and 7.40 mGy for newborn to adult size, respectively. In addition, half dose scans were acquired on EICT. Each phantom was then scanned on a PCCT (Siemens Alpha) using a universal 120-kV protocol with the same full dose and half dose as determined above on the EICT scanner. All other parameters matched to EICT settings. Virtual monoenergetic images were generated from PCCT scans between 40 and 80 keV with a 5-keV interval. Image quality metrics were compared between PCCT VMIs and EICT, including image noise (measured as standard deviation of solid water), contrast-to-noise ratio (CNR) (measured at iodine inserts with solid water as background), and noise power spectrum (measured in uniform phantom regions). RESULTS Noise at a PCCT VMI of 70 keV (7.0 ± 0.6 HU for newborn, 14.7 ± 1.6 HU for adult) is comparable ( P > 0.05, t test) or significantly lower ( P < 0.05, t test) compared with EICT (7.8 ± 0.8 HU for newborn, 15.3 ± 1.5 HU for adult). Iodine CNR from PCCT VMI at 50 keV (50.8 ± 8.4 for newborn, 27.3 ± 2.8 for adult) is comparable ( P > 0.05, t test) or significantly higher ( P < 0.05, t test) to the corresponding EICT measurements (57.5 ± 6.7 for newborn, 13.8 ± 1.7 for adult). The noise power spectrum curve shape of PCCT VMI is similar to EICT, despite PCCT VMI exhibiting higher noise at low keV levels. CONCLUSIONS The universal PCCT 120 kV with ultra-high pitch and postprocessed VMIs demonstrated equivalent or improved performance in noise (70 keV) and iodine CNR (50 keV) for pediatric abdominal CT, compared with size-specific kV images on the EICT.
Collapse
Affiliation(s)
- Wei Zhou
- From the Department of Radiology, University of Colorado, Anschutz Medical Campus, Aurora, CO (W.Z., D.H., L.P.B., J.W.); Department of Radiology, Children's Hospital Colorado, Aurora, CO (L.P.B., J.W.); and Bioinformatics and Computational Biology, University of Minnesota, St Paul, MN (X.Z.)
| | | | | | | | | |
Collapse
|
4
|
Spielberg DR, Weinman J, DeBoer EM. Advancements in imaging in ChILD. Pediatr Pulmonol 2024; 59:2276-2285. [PMID: 37222402 DOI: 10.1002/ppul.26487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 05/08/2023] [Accepted: 05/09/2023] [Indexed: 05/25/2023]
Abstract
Interstitial and diffuse lung diseases in children constitute a range of congenital and acquired disorders. These disorders present with signs and symptoms of respiratory disease accompanied by diffuse radiographic changes. In many cases, radiographic findings are nonspecific, while in other disorders, chest computed tomography (CT) is diagnostic in the appropriate context. Regardless, chest imaging remains central in the evaluation of the patient with suspected childhood interstitial lung disease (chILD). Several newly described chILD entities, spanning both genetic and acquired etiologies, have imaging that aid in their diagnoses. Advances in CT scanning technology and CT analysis techniques continue to improve scan quality as well as expand use of chest CT as a research tool. Finally, ongoing research is expanding use of imaging modalities without ionizing radiation. Magnetic resonance imaging is being applied to investigate pulmonary structure and function, and ultrasound of the lung and pleura is a novel technique with an emerging role in chILD disorders. This review describes the current state of imaging in chILD including recently described diagnoses, advances in conventional imaging techniques and applications, and evolving new imaging modalities that expand the clinical and research roles for imaging in these disorders.
Collapse
Affiliation(s)
- David R Spielberg
- Department of Pediatrics, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Jason Weinman
- Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Emily M DeBoer
- Department of Pediatrics, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| |
Collapse
|
5
|
Jaruvongvanich V, Muangsomboon K, Teerasamit W, Suvannarerg V, Komoltri C, Thammakittiphan S, Lornimitdee W, Ritsamrej W, Chaisue P, Pongnapang N, Apisarnthanarak P. Optimizing computed tomography image reconstruction for focal hepatic lesions: Deep learning image reconstruction vs iterative reconstruction. Heliyon 2024; 10:e34847. [PMID: 39170325 PMCID: PMC11336302 DOI: 10.1016/j.heliyon.2024.e34847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 05/27/2024] [Accepted: 07/17/2024] [Indexed: 08/23/2024] Open
Abstract
Background Deep learning image reconstruction (DLIR) is a novel computed tomography (CT) reconstruction technique that minimizes image noise, enhances image quality, and enables radiation dose reduction. This study aims to compare the diagnostic performance of DLIR and iterative reconstruction (IR) in the evaluation of focal hepatic lesions. Methods We conducted a retrospective study of 216 focal hepatic lesions in 109 adult participants who underwent abdominal CT scanning at our institution. We used DLIR (low, medium, and high strength) and IR (0 %, 10 %, 20 %, and 30 %) techniques for image reconstruction. Four experienced abdominal radiologists independently evaluated focal hepatic lesions based on five qualitative aspects (lesion detectability, lesion border, diagnostic confidence level, image artifact, and overall image quality). Quantitatively, we measured and compared the level of image noise for each technique at the liver and aorta. Results There were significant differences (p < 0.001) among the seven reconstruction techniques in terms of lesion borders, image artifacts, and overall image quality. Low-strength DLIR (DLIR-L) exhibited the best overall image quality. Although high-strength DLIR (DLIR-H) had the least image noise and fewest artifacts, it also had the lowest scores for lesion borders and overall image quality. Image noise showed a weak to moderate positive correlation with participants' body mass index and waist circumference. Conclusions The optimal-strength DLIR significantly improved overall image quality for evaluating focal hepatic lesions compared to the IR technique. DLIR-L achieved the best overall image quality while maintaining acceptable levels of image noise and quality of lesion borders.
Collapse
Affiliation(s)
- Varin Jaruvongvanich
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Kobkun Muangsomboon
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Wanwarang Teerasamit
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Voraparee Suvannarerg
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Chulaluk Komoltri
- Division of Research and Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Sastrawut Thammakittiphan
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Wimonrat Lornimitdee
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Witchuda Ritsamrej
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Parinya Chaisue
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Napapong Pongnapang
- Department of Radiological Technology, Faculty of Medical Technology, Mahidol University, Bangkok, Thailand
| | - Piyaporn Apisarnthanarak
- Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
6
|
Kibrom BT, Manyazewal T, Demma BD, Feleke TH, Kabtimer AS, Ayele ND, Korsa EW, Hailu SS. Emerging technologies in pediatric radiology: current developments and future prospects. Pediatr Radiol 2024; 54:1428-1436. [PMID: 39012407 DOI: 10.1007/s00247-024-05997-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 07/02/2024] [Accepted: 07/03/2024] [Indexed: 07/17/2024]
Abstract
Radiological imaging is a crucial diagnostic tool for the pediatric population. However, it is associated with several unique challenges in this age group compared to adults. These challenges mainly come from the fact that children are not small-sized adults and differ in development, anatomy, physiology, and pathology compared to adults. This paper reviews relevant articles published between January 2015 and October 2023 to analyze challenges associated with imaging technologies currently used in pediatric radiology, emerging technologies, and their role in resolving the challenges and future prospects of pediatric radiology. In recent decades, imaging technologies have advanced rapidly, developing advanced ultrasound, computed tomography, magnetic resonance, nuclear imaging, teleradiology, artificial intelligence, machine learning, three-dimensional printing, radiomics, and radiogenomics, among many others. By prioritizing the unique needs of pediatric patients while developing such technologies, we can significantly alleviate the challenges faced in pediatric radiology.
Collapse
Affiliation(s)
- Bethlehem T Kibrom
- Centre for Innovative Drug Development and Therapeutic Trials for Africa (CDT-Africa), College of Health Sciences, Addis Ababa University, P.O. Box 9086, Addis Ababa, Ethiopia.
| | - Tsegahun Manyazewal
- Centre for Innovative Drug Development and Therapeutic Trials for Africa (CDT-Africa), College of Health Sciences, Addis Ababa University, P.O. Box 9086, Addis Ababa, Ethiopia
| | - Biruk D Demma
- College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Tesfahunegn H Feleke
- Centre for Innovative Drug Development and Therapeutic Trials for Africa (CDT-Africa), College of Health Sciences, Addis Ababa University, P.O. Box 9086, Addis Ababa, Ethiopia
- Potomac Urology Clinic, Alexandria, VA, USA
| | | | - Nitsuh D Ayele
- College of Health Sciences, Wolkite University, Wolkite, Ethiopia
| | - Eyasu W Korsa
- Department of Radiology, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Samuel S Hailu
- Department of Radiology, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| |
Collapse
|
7
|
Stordalen MB, Bray S, Stringer F, Stonebrook C, Guilherme S, Bray JP. Awake 160-Slice Computed Tomography for Upper Airway Evaluation in 17 Dogs. Vet Sci 2024; 11:342. [PMID: 39195796 PMCID: PMC11360448 DOI: 10.3390/vetsci11080342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 07/23/2024] [Accepted: 07/26/2024] [Indexed: 08/29/2024] Open
Abstract
This study investigated using a 160-slice multidetector computed tomography (CT) scanner for conscious image acquisition in dogs with upper airway disease, and describes findings in dogs that had previously undergone soft palate surgery. Seventeen client-owned dogs with upper airway disease were retrospectively reviewed, and classified into three groups: group I, "untreated brachycephalic obstructive airway syndrome (BOAS) patients"; group II, "previously treated BOAS patients"; and group III, "patients with respiratory disease other than BOAS". Data included signalment, clinical history, direct laryngoscopy and endoscopy findings, previous surgeries and CT findings. CT scans in group I revealed overlong and thickened soft palates in all dogs, and signs of laryngeal collapse in four dogs. Patients in group II exhibited normal soft palate lengths, while patients in group III displayed various findings such as nasopharyngeal narrowing and tracheal collapse. Upper airway examinations under general anaesthesia confirmed most CT findings. This study demonstrates the feasibility and value of conscious CT scanning for assessing upper airway diseases in dogs, providing valuable diagnostic information while eliminating the need for chemical immobilisation, thus reducing patient stress and cost. These findings offer new insight into upper airway anatomy in awake patients, especially in brachycephalic breeds, and lay a foundation for future research.
Collapse
|
8
|
He Z, Chen Q, Duan X, Zhong Y, Zhu L, Mou N, Yang X, Cao Y, Han Z, He H, Wu S, Wang G, Qin X, Qu K, Zhang K, Liu J, Wu W. Reactive oxygen species-responsive nano-platform with dual-targeting and fluorescent lipid-specific imaging capabilities for the management of atherosclerotic plaques. Acta Biomater 2024; 181:375-390. [PMID: 38734284 DOI: 10.1016/j.actbio.2024.05.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 04/04/2024] [Accepted: 05/05/2024] [Indexed: 05/13/2024]
Abstract
Atherosclerosis (AS), a pathological cause of cardiovascular disease, results from endothelial injury, local progressive inflammation, and excessive lipid accumulation. AS plaques rich in foam cells are prone to rupture and form thrombus, which can cause life-threatening complications. Therefore, the assessment of atherosclerotic plaque vulnerability and early intervention are crucial in reducing the mortality rates associated with cardiovascular disease. In this work, A fluorescent probe FC-TPA was synthesized, which switches the fluorescence state between protonated and non-protonated, reducing background fluorescence and enhancing imaging signal-to-noise ratio. On this basis, FC-TPA is loaded into cyclodextrin (CD) modified with phosphatidylserine targeting peptide (PTP) and coated with hyaluronic acid (HA) to construct the intelligent responsive diagnostic nanoplatform (HA@PCFT). HA@PCFT effectively targets atherosclerotic plaques, utilizing dual targeting mechanisms. HA binds strongly to CD44, while PTP binds to phosphatidylserine, enabling nanoparticle aggregation at the lesion site. ROS acts as a smart release switch for probes. Both in vitro and in vivo evaluations confirm impressive lipid-specific fluorescence imaging capabilities of HA@PCFT nanoparticles (NPs). The detection of lipid load in atherosclerotic plaque by fluorescence imaging will aid in assessing the vulnerability of atherosclerotic plaque. STATEMENT OF SIGNIFICANCE: Currently, numerous fluorescent probes have been developed for lipid imaging. However, some challenges including inadequate water solubility, nonspecific distribution patterns, and fluorescence background interference, have greatly limited their further applications in vivo. To overcome these limitations, a fluorescent molecule has been designed and synthesized, thoroughly investigating its photophysical properties through both theoretical and experimental approaches. Interestingly, this fluorescent molecule exhibits the reversible fluorescence switching capabilities, mediated by hydrogen bonds, which effectively mitigate background fluorescence interference. Additionally, the fluorescent molecules has been successfully loaded into nanocarriers functionalized with the active targeting abilities, which has significantly improved the solubility of the fluorescent molecules and reduced their nonspecific distribution in vivo for an efficient target imaging in atherosclerosis. This study provides a valuable reference for evaluating the performance of such fluorescent dyes, and offers a promising perspective on the design of the target delivery systems for atherosclerosis.
Collapse
Affiliation(s)
- Zhigui He
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Qiao Chen
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Xinmei Duan
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Yuan Zhong
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Li Zhu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Nianlian Mou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Xu Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Yu Cao
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Zhiqiang Han
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Houhua He
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Shuai Wu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China
| | - Guixue Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China; JinFeng Laboratory, Chongqing 401329, China
| | - Xian Qin
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China; Chongqing Municipality Clinical Research Center for Endocrinology and Metabolic Diseases, Chongqing University Three Gorges Hospital, Chongqing 404000, China
| | - Kai Qu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China; Chongqing Municipality Clinical Research Center for Endocrinology and Metabolic Diseases, Chongqing University Three Gorges Hospital, Chongqing 404000, China
| | - Kun Zhang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China; Chongqing Municipality Clinical Research Center for Endocrinology and Metabolic Diseases, Chongqing University Three Gorges Hospital, Chongqing 404000, China.
| | - Jie Liu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China.
| | - Wei Wu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400030, China; JinFeng Laboratory, Chongqing 401329, China.
| |
Collapse
|
9
|
Horst KK, Cao JY, McCollough CH, El-Ali A, Frush DP, Siegel MJ, Ramirez-Giraldo JC, O'Donnell T, Bache S, Yu L. Multi-institutional Protocol Guidance for Pediatric Photon-counting CT. Radiology 2024; 311:e231741. [PMID: 38771176 DOI: 10.1148/radiol.231741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2024]
Abstract
Performing CT in children comes with unique challenges such as greater degrees of patient motion, smaller and densely packed anatomy, and potential risks of radiation exposure. The technical advancements of photon-counting detector (PCD) CT enable decreased radiation dose and noise, as well as increased spatial and contrast resolution across all ages, compared with conventional energy-integrating detector CT. It is therefore valuable to review the relevant technical aspects and principles specific to protocol development on the new PCD CT platform to realize the potential benefits for this population. The purpose of this article, based on multi-institutional clinical and research experience from pediatric radiologists and medical physicists, is to provide protocol guidance for use of PCD CT in the imaging of pediatric patients.
Collapse
Affiliation(s)
- Kelly K Horst
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| | - Joseph Y Cao
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| | - Cynthia H McCollough
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| | - Alex El-Ali
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| | - Donald P Frush
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| | - Marilyn J Siegel
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| | - Juan Carlos Ramirez-Giraldo
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| | - Tom O'Donnell
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| | - Steve Bache
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| | - Lifeng Yu
- From the Department of Radiology, Division of Pediatric Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905 (K.K.H., C.H.M., L.Y.); Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham, NC (J.Y.C., D.P.F., S.B.); Department of Radiology, Division of Pediatric Radiology, NYU Grossman School of Medicine, New York, NY (A.E.A.); Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.J.S.); and Siemens Medical Solutions USA, Malvern, Pa (J.C.R.G., T.O.)
| |
Collapse
|
10
|
Horst KK, Yu L, McCollough CH, Esquivel A, Thorne JE, Rajiah PS, Baffour F, Hull NC, Weber NM, Thacker PG, Thomas KB, Binkovitz LA, Guerin JB, Fletcher JG. Potential benefits of photon counting detector computed tomography in pediatric imaging. Br J Radiol 2023; 96:20230189. [PMID: 37750939 PMCID: PMC10646626 DOI: 10.1259/bjr.20230189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 08/29/2023] [Accepted: 08/30/2023] [Indexed: 09/27/2023] Open
Abstract
Photon counting detector (PCD) CT represents the newest advance in CT technology, with improved radiation dose efficiency, increased spatial resolution, inherent spectral imaging capabilities, and the ability to eliminate electronic noise. Its design fundamentally differs from conventional energy integrating detector CT because photons are directly converted to electrical signal in a single step. Rather than converting X-rays to visible light and having an output signal that is a summation of energies, PCD directly counts each photon and records its individual energy information. The current commercially available PCD-CT utilizes a dual-source CT geometry, which allows 66 ms cardiac temporal resolution and high-pitch (up to 3.2) scanning. This can greatly benefit pediatric patients by facilitating high quality fast scanning to allow sedation-free imaging. The energy-resolving nature of the utilized PCDs allows "always-on" dual-energy imaging capabilities, such as the creation of virtual monoenergetic, virtual non-contrast, virtual non-calcium, and other material-specific images. These features may be combined with high-resolution imaging, made possible by the decreased size of individual detector elements and the absence of interelement septa. This work reviews the foundational concepts associated with PCD-CT and presents examples to highlight the benefits of PCD-CT in the pediatric population.
Collapse
Affiliation(s)
- Kelly K. Horst
- Pediatric Radiology Division, Department of Radiology, Mayo Clinic, Rochester, United States
| | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, United States
| | | | - Andrea Esquivel
- Department of Radiology, Mayo Clinic, Rochester, United States
| | | | | | - Francis Baffour
- Department of Radiology, Mayo Clinic, Rochester, United States
| | - Nathan C. Hull
- Pediatric Radiology Division, Department of Radiology, Mayo Clinic, Rochester, United States
| | | | - Paul G. Thacker
- Pediatric Radiology Division, Department of Radiology, Mayo Clinic, Rochester, United States
| | - Kristen B. Thomas
- Pediatric Radiology Division, Department of Radiology, Mayo Clinic, Rochester, United States
| | - Larry A. Binkovitz
- Pediatric Radiology Division, Department of Radiology, Mayo Clinic, Rochester, United States
| | - Julie B. Guerin
- Department of Radiology, Mayo Clinic, Rochester, United States
| | | |
Collapse
|
11
|
Peña-Trujillo V, Gallo-Bernal S, Tung EL, Gee MS. Pediatric Applications of Dual-Energy Computed Tomography. Radiol Clin North Am 2023; 61:1069-1083. [PMID: 37758357 DOI: 10.1016/j.rcl.2023.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
There is renewed interest in novel pediatric dual-energy computed tomography (DECT) applications that can image awake patients faster and at low radiation doses. DECT enables the simultaneous acquisition of 2 data sets at different energy levels, allowing for better material characterization and unique image reconstructions that enhance image analysis and provide quantitative and qualitative information about tissue composition. Pediatric DECT reduces radiation doses further while accelerating image acquisition and improving motion robustness. Current applications include the improved evaluation of congenital and acquired cardiovascular anomalies, lung perfusion and ventilation, renal stone composition, tumor extension and treatment response, and gastrointestinal diseases.
Collapse
Affiliation(s)
- Valeria Peña-Trujillo
- Division of Pediatric Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA. https://twitter.com/valeria_pt22
| | - Sebastian Gallo-Bernal
- Division of Pediatric Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA. https://twitter.com/SebGal1230
| | - Erik L Tung
- Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA. https://twitter.com/ErikTungMD
| | - Michael S Gee
- Division of Pediatric Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
12
|
Abstract
Dual-energy CT has expanded the potential of thoracic imaging in both children and adults. Data processing allows material- and energy-specific reconstructions, which improve material differentiation and tissue characterization compared with single-energy CT. Material-specific reconstructions include iodine, virtual unenhanced, perfusion blood volume, and lung vessel images, which can improve assessment of vascular, mediastinal, and parenchymal abnormalities. The energy-specific reconstruction algorithm allows virtual monoenergetic reconstructions, including low-energy images to increase iodine conspicuity and high-energy images to reduce beam-hardening and metal artifacts. This review highlights dual-energy CT principles, hardware, and postprocessing algorithms; the clinical applications of dual-energy CT; and the potential benefits of photon counting (the most recently introduced iteration of spectral imaging) in pediatric thoracic imaging.
Collapse
Affiliation(s)
- Jordan B Rapp
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA
| | - David M Biko
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA
| | - Marilyn J Siegel
- Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St. Louis, MO 63110
| |
Collapse
|
13
|
Tan Z, Zhang L, Sun X, Yang M, Makamure J, Wu H, Wang J. Dual-Layer Detector Head CT to Maintain Image Quality While Reducing the Radiation Dose in Pediatric Patients. AJNR Am J Neuroradiol 2023; 44:1212-1218. [PMID: 37735089 PMCID: PMC10549953 DOI: 10.3174/ajnr.a7999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 08/02/2023] [Indexed: 09/23/2023]
Abstract
BACKGROUND AND PURPOSE Radiation exposure in the CT diagnostic imaging process is a conspicuous concern in pediatric patients. This study aimed to evaluate whether 60-keV virtual monoenergetic images of the pediatric cranium in dual-layer CT can reduce the radiation dose while maintaining image quality compared with conventional images. MATERIALS AND METHODS One hundred six unenhanced pediatric head scans acquired by dual-layer CT were retrospectively assessed. The patients were assigned to 2 groups of 53 and scanned with 250 and 180 mAs, respectively. Dose-length product values were retrieved, and noise, SNR, and contrast-to-noise ratio were calculated for each case. Two radiologists blinded to the reconstruction technique used evaluated image quality on a 5-point Likert scale. Statistical assessment was performed with ANOVA and the Wilcoxon test, adjusted for multiple comparisons. RESULTS Mean dose-length product values were 717.47 (SD, 41.52) mGy×cm and 520.74 (SD, 42) mGy×cm for the 250- and 180-mAs groups, respectively. Irrespective of the radiation dose, noise was significantly lower, SNR and contrast-to-noise ratio were significantly higher, and subjective analysis revealed significant superiority of 60-keV virtual monoenergetic images compared with conventional images (all P < .001). SNR, contrast-to-noise ratio, and subjective evaluation in 60-keV virtual monoenergetic images were not significantly different between the 2 scan groups (P > .05). Radiation dose parameters were significantly lower in the 180-mAs group compared with the 250-mAs group (P < .001). CONCLUSIONS Dual-layer CT 60-keV virtual monoenergetic images allowed a radiation dose reduction of 28% without image-quality loss in pediatric cranial CT.
Collapse
Affiliation(s)
- Zhengwu Tan
- From the Department of Radiology (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
- Hubei Province Key Laboratory of Molecular Imaging (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Wuhan, Hubei, China
| | - Lan Zhang
- From the Department of Radiology (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
- Hubei Province Key Laboratory of Molecular Imaging (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Wuhan, Hubei, China
| | - Xiaojie Sun
- From the Department of Radiology (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
- Hubei Province Key Laboratory of Molecular Imaging (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Wuhan, Hubei, China
| | - Ming Yang
- From the Department of Radiology (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
- Hubei Province Key Laboratory of Molecular Imaging (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Wuhan, Hubei, China
| | - Joyman Makamure
- From the Department of Radiology (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
- Hubei Province Key Laboratory of Molecular Imaging (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Wuhan, Hubei, China
| | - Hongying Wu
- From the Department of Radiology (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
- Hubei Province Key Laboratory of Molecular Imaging (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Wuhan, Hubei, China
| | - Jing Wang
- From the Department of Radiology (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
- Hubei Province Key Laboratory of Molecular Imaging (Z.T., L.Z., X.S., M.Y., J.M., H.W., J.W.), Wuhan, Hubei, China
| |
Collapse
|
14
|
Cademartiri F, Meloni A, Pistoia L, Degiorgi G, Clemente A, De Gori C, Positano V, Celi S, Berti S, Emdin M, Panetta D, Menichetti L, Punzo B, Cavaliere C, Bossone E, Saba L, Cau R, Grutta LL, Maffei E. Dual Source Photon-Counting Computed Tomography-Part II: Clinical Overview of Neurovascular Applications. J Clin Med 2023; 12:jcm12113626. [PMID: 37297821 DOI: 10.3390/jcm12113626] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/15/2023] [Accepted: 05/18/2023] [Indexed: 06/12/2023] Open
Abstract
Photon-counting detector (PCD) is a novel computed tomography detector technology (photon-counting computed tomography-PCCT) that presents many advantages in the neurovascular field, such as increased spatial resolution, reduced radiation exposure, and optimization of the use of contrast agents and material decomposition. In this overview of the existing literature on PCCT, we describe the physical principles, the advantages and the disadvantages of conventional energy integrating detectors and PCDs, and finally, we discuss the applications of the PCD, focusing specifically on its implementation in the neurovascular field.
Collapse
Affiliation(s)
| | - Antonella Meloni
- Department of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy
- Department of Bioengineering, Fondazione Monasterio/CNR, 56124 Pisa, Italy
| | - Laura Pistoia
- Department of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy
| | - Giulia Degiorgi
- Department of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy
| | - Alberto Clemente
- Department of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy
| | - Carmelo De Gori
- Department of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy
| | - Vincenzo Positano
- Department of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy
- Department of Bioengineering, Fondazione Monasterio/CNR, 56124 Pisa, Italy
| | - Simona Celi
- BioCardioLab, Department of Bioengineering, Fondazione Monasterio/CNR, 54100 Massa, Italy
| | - Sergio Berti
- Cardiology Unit, Ospedale del Cuore, Fondazione Monasterio/CNR, 54100 Massa, Italy
| | - Michele Emdin
- Department of Cardiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy
| | - Daniele Panetta
- Institute of Clinical Physiology, National Council of Research, 56124 Pisa, Italy
| | - Luca Menichetti
- Institute of Clinical Physiology, National Council of Research, 56124 Pisa, Italy
| | - Bruna Punzo
- Department of Radiology, IRCCS SynLab-SDN, 80131 Naples, Italy
| | - Carlo Cavaliere
- Department of Radiology, IRCCS SynLab-SDN, 80131 Naples, Italy
| | - Eduardo Bossone
- Department of Cardiology, Ospedale Cardarelli, 80131 Naples, Italy
| | - Luca Saba
- Department of Radiology, University Hospital, 09042 Monserrato, Italy
| | - Riccardo Cau
- Department of Radiology, University Hospital, 09042 Monserrato, Italy
| | - Ludovico La Grutta
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties-ProMISE, Department of Radiology, University Hospital "P. Giaccone", 90127 Palermo, Italy
| | - Erica Maffei
- Department of Radiology, Fondazione Monasterio/CNR, 56124 Pisa, Italy
| |
Collapse
|
15
|
Costa PR, Tomal A, de Oliveira Castro JC, Nunes IPF, Nersissian DY, Sawamura MVY, Leão Filho H, Lee C. Diagnostic reference level quantities for adult chest and abdomen-pelvis CT examinations: correlation with organ doses. Insights Imaging 2023; 14:60. [PMID: 37024637 PMCID: PMC10079797 DOI: 10.1186/s13244-023-01403-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 03/11/2023] [Indexed: 04/08/2023] Open
Abstract
OBJECTIVES To evaluate correlations between DRL quantities (DRLq) stratified into patient size groups for non-contrast chest and abdomen-pelvis CT examinations in adult patients and the corresponding organ doses. METHODS This study presents correlations between DRLq (CTDIvol, DLP and SSDE) stratified into patient size ranges and corresponding organ doses shared in four groups: inside, peripheral, distributed and outside. The demographic, technical and dosimetric parameters were used to identify the influence of these quantities in organ doses. A robust statistical method was implemented in order to establish these correlations and its statistical significance. RESULTS Median values of the grouped organ doses are presented according to the effective diameter ranges. Organ doses in the regions inside the imaged area are higher than the organ doses in peripheral, distributed and outside regions, excepted to the peripheral doses associated with chest examinations. Different levels of statistical significance between organ doses and the DRLq were presented. CONCLUSIONS Correlations between DRLq and target-organ doses associated with clinical practice can support guidance's to the establishment of optimization criteria. SSDE demonstrated to be significant in the evaluation of organ doses is also highlighted. The proposed model allows the design of optimization actions with specific risk-reduction results.
Collapse
Affiliation(s)
- Paulo Roberto Costa
- Institute of Physics, University of São Paulo, R. Do Matão, 1371, Butantã, São Paulo, SP, 05508-090, Brazil.
| | - Alessandra Tomal
- Institute of Physics Gleb Watagin, University of Campinas, Campinas, Brazil
| | | | | | - Denise Yanikian Nersissian
- Institute of Physics, University of São Paulo, R. Do Matão, 1371, Butantã, São Paulo, SP, 05508-090, Brazil
| | | | - Hilton Leão Filho
- Division of Radiology, Medical School, University of São Paulo, São Paulo, Brazil
| | - Choonsik Lee
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health (NIH), Bethesda, MD, USA
| |
Collapse
|
16
|
Elhakim T, Trinh K, Mansur A, Bridge C, Daye D. Role of Machine Learning-Based CT Body Composition in Risk Prediction and Prognostication: Current State and Future Directions. Diagnostics (Basel) 2023; 13:968. [PMID: 36900112 PMCID: PMC10000509 DOI: 10.3390/diagnostics13050968] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/11/2023] [Accepted: 02/18/2023] [Indexed: 03/08/2023] Open
Abstract
CT body composition analysis has been shown to play an important role in predicting health and has the potential to improve patient outcomes if implemented clinically. Recent advances in artificial intelligence and machine learning have led to high speed and accuracy for extracting body composition metrics from CT scans. These may inform preoperative interventions and guide treatment planning. This review aims to discuss the clinical applications of CT body composition in clinical practice, as it moves towards widespread clinical implementation.
Collapse
Affiliation(s)
- Tarig Elhakim
- Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA 19104, USA
- Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Kelly Trinh
- School of Medicine, Texas Tech University Health Sciences Center, School of Medicine, Lubbock, TX 79430, USA
| | - Arian Mansur
- Harvard Medical School, Harvard University, Boston, MA 02115, USA
| | - Christopher Bridge
- Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA
- Harvard Medical School, Harvard University, Boston, MA 02115, USA
| | - Dania Daye
- Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA
- Harvard Medical School, Harvard University, Boston, MA 02115, USA
| |
Collapse
|
17
|
Azzi JL, Seo C, McInnis G, Urichuk M, Rabbani R, Rozovsky K, Leitao DJ. A systematic review and meta-analysis of computed tomography in the diagnosis of pediatric foreign body aspiration. Int J Pediatr Otorhinolaryngol 2023; 165:111429. [PMID: 36621123 DOI: 10.1016/j.ijporl.2022.111429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 12/05/2022] [Accepted: 12/28/2022] [Indexed: 12/31/2022]
Abstract
INTRODUCTION Rigid bronchoscopy remains the gold standard for the diagnosis of foreign body aspiration (FBA) despite high rates of negative bronchoscopies. The use of computed tomography (CT) imaging in the assessment of FBA has recently emerged and could help obviate unnecessary bronchoscopy in these patients. The aim of this study is to assess the diagnostic accuracy of CT in the diagnosis of pediatric FBA. METHODS A systematic literature review was conducted to identify studies reporting the use of CT imaging in suspected pediatric FBA. The search included published articles in Ovid MEDLINE, Ovid EMBASE, PubMed MEDLINE and Web of Science. The search strategy included all articles from inception of the database to January 2021. Manuscripts were reviewed and graded for quality using the QUADAS-2 tool. Subgroup analyses based on the use of virtual bronchoscopy (VB) and sedation was conducted. A meta-analysis evaluating the use of VB in the diagnosis of FBA was also conducted. RESULTS Sixteen manuscripts met all inclusion criteria. In total, 2056 pediatric patients ranging from 0.3 to 15 years underwent CT for suspected FBA. The sensitivity and specificity of CT were 98.8% and 96.6%, respectively. VB was used in 71.4% (1391/1948) of patients while sedation during CT was required in 70.2% (1263/1800) of patients. Radiation dosing ranged from 0.04 to 2 mSv, 0.99-59.1 mGy-cm and 0.03-16.99 mGy. CONCLUSION CT can accurately diagnose pediatric FBA and can help decrease the rate of unnecessary bronchoscopies with an acceptable dose of radiation.
Collapse
Affiliation(s)
- Jayson Lee Azzi
- Department of Otolaryngology - Head and Neck Surgery, University of Manitoba, Winnipeg, MB, Canada
| | - Chanhee Seo
- Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Graham McInnis
- Department of Radiology, University of Manitoba, Winnipeg, MB, Canada
| | - Matthew Urichuk
- Max Rady College of Medicine, University of Manitoba, Winnipeg, MB, Canada
| | - Rasheda Rabbani
- Department of George & Fay Yee Centre for Healthcare Innovation (CHI), University of Manitoba, Winnipeg, MB, Canada
| | - Katya Rozovsky
- Department of Radiology, University of Manitoba, Winnipeg, MB, Canada
| | - Darren J Leitao
- Department of Otolaryngology - Head and Neck Surgery, University of Manitoba, Winnipeg, MB, Canada.
| |
Collapse
|
18
|
Yu Y, Geffen B, McCrary H, Dunya G, Rampton J, Zhang C, Presson AP, Poe D, Park AH. Measurements of The Pediatric Cartilaginous Eustachian Tube: Implications for Balloon Dilation. Laryngoscope 2023; 133:396-402. [PMID: 35338653 PMCID: PMC9510602 DOI: 10.1002/lary.30113] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 02/26/2022] [Accepted: 03/01/2022] [Indexed: 01/22/2023]
Abstract
OBJECTIVES (1) Measure the cartilaginous Eustachian tube (ET) length using a computed tomography (CT) scan and (2) develop a prediction model to measure this length without the need of a CT scan. STUDY DESIGN CT measurements in children. SETTING Children's Hospital. METHODS CT scans were reformatted to project the cranial and caudal limits of the cartilaginous ET. The length was measured in 193 children who underwent a neck CT scan for nonotologic indications. Five physicians independently reviewed all or some of these measures. Four different models based on age, age ranges, weight, and height were created and compared to predict ET length. RESULTS The cartilaginous ET length was 25.3 ± 3.1 mm for the right and for the left ear. The mean ET length for the females was statistically significantly less than the length in males. The lower ET lengths in children as old as 5 years of age were less than the 2 cm adult criteria used for catheter insertion. All 4 models performed equally well in predicting ET length. Model number 4, which is based on height, was the easiest to calculate ET length. CONCLUSION The cartilaginous portion of the pediatric ET can be measured with good precision using reformatted CT images. We caution against using the "adult" criteria of 2 cm for catheter insertion in children, especially those younger than 5 years of age. We recommend using a model utilizing height measures to estimate ET length or direct measurements from a reformatted CT scan. LEVEL OF EVIDENCE NA Laryngoscope, 133:396-402, 2023.
Collapse
Affiliation(s)
- Yuan Yu
- Department of Surgery, Shanghai Fifth People's Hospital, Fudan University, Shanghai, China
| | - Brent Geffen
- Division of Otolaryngology-Head and Neck Surgery, University of Utah, Salt Lake City, Utah, USA
| | - Hilary McCrary
- Division of Otolaryngology-Head and Neck Surgery, University of Utah, Salt Lake City, Utah, USA
| | - Gabriel Dunya
- Department of Otorhinolaryngology Head and Neck Surgery, Lebanese American University Medical Center-Rizk Hospital, Beirut, Lebanon
| | - John Rampton
- Pediatric Radiology, Intermountain Medical Group, Salt Lake City, Utah, USA
| | - Chong Zhang
- Department of Internal Medicine- Epidemiology, University of Utah, Salt Lake City, Utah, USA
| | - Angela P Presson
- Department of Internal Medicine- Epidemiology, University of Utah, Salt Lake City, Utah, USA
| | - Dennis Poe
- Department of Otolaryngology and Communication Enhancement, Harvard Medical School, Boston, Massachusetts, USA
| | - Albert H Park
- Division of Otolaryngology-Head and Neck Surgery, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
19
|
Dabli D, Loisy M, Frandon J, de Oliveira F, Meerun AM, Guiu B, Beregi JP, Greffier J. Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study. Eur Radiol Exp 2023; 7:1. [PMID: 36617620 PMCID: PMC9826773 DOI: 10.1186/s41747-022-00314-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Accepted: 11/05/2022] [Indexed: 01/10/2023] Open
Abstract
BACKGROUND To assess the impact of the new version of a deep learning (DL) spectral reconstruction on image quality of virtual monoenergetic images (VMIs) for contrast-enhanced abdominal computed tomography in the rapid kV-switching platform. METHODS Two phantoms were scanned with a rapid kV-switching CT using abdomen-pelvic CT examination parameters at dose of 12.6 mGy. Images were reconstructed using two versions of DL spectral reconstruction algorithms (DLSR V1 and V2) for three reconstruction levels. The noise power spectrum (NSP) and task-based transfer function at 50% (TTF50) were computed at 40/50/60/70 keV. A detectability index (d') was calculated for enhanced lesions at low iodine concentrations: 2, 1, and 0.5 mg/mL. RESULTS The noise magnitude was significantly lower with DLSR V2 compared to DLSR V1 for energy levels between 40 and 60 keV by -36.5% ± 1.4% (mean ± standard deviation) for the standard level. The average NPS frequencies increased significantly with DLSR V2 by 23.7% ± 4.2% for the standard level. The highest difference in TTF50 was observed at the mild level with a significant increase of 61.7% ± 11.8% over 40-60 keV energy with DLSR V2. The d' values were significantly higher for DLSR V2 versus DLSR V1. CONCLUSIONS The DLSR V2 improves image quality and detectability of low iodine concentrations in VMIs compared to DLSR V1. This suggests a great potential of DLSR V2 to reduce iodined contrast doses.
Collapse
Affiliation(s)
- Djamel Dabli
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
| | - Maeliss Loisy
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| | - Julien Frandon
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| | - Fabien de Oliveira
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| | - Azhar Mohamad Meerun
- grid.157868.50000 0000 9961 060XSaint-Eloi University Hospital, Montpellier, France
| | - Boris Guiu
- grid.157868.50000 0000 9961 060XSaint-Eloi University Hospital, Montpellier, France
| | - Jean-Paul Beregi
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| | - Joël Greffier
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| |
Collapse
|
20
|
Burger RK, Figueroa J, Parikh AK, Riedesel EL. Impact of a Faster Computed Tomography Scanner on Sedation for Pediatric Head Computed Tomography Scans in 2 Large Emergency Departments-A Retrospective Study. Pediatr Emerg Care 2023; 39:e6-e10. [PMID: 35947049 DOI: 10.1097/pec.0000000000002816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
OBJECTIVES Children in the emergency department (ED) often require sedation for head computed tomography (CT) to ensure adequate image quality. Image acquisition time for a head CT using a conventional single-source CT scanner is approximately 12 seconds; however, after installation in November 2017 of 2 new dual-source dual-energy CT scanners, that time decreased to 1 to 3 seconds. We hypothesized that fewer patients would require sedation using the faster CT scanners. METHODS We conducted a retrospective chart review of patients aged 0 to 18 years undergoing head CT at 2 pediatric EDs within 1 hospital system, 2 years before and 2 years after installation of the faster CT scanner. Patients undergoing multiple CTs or other procedures were excluded. Demographic information, diagnosis, disposition, sedatives (chloral hydrate, dexmedetomidine, etomidate, fentanyl, ketamine, midazolam, methohexital, pentobarbital, and propofol) administered before imaging, and ED length of stay were analyzed. RESULTS A total of 15,175 patient encounters met inclusion criteria, 7412 before and 7763 after installation of the new CT. The median age was 7 years and 44% were female. Before the new CT scanner was installed 8% required sedation, compared with 7% after (effect size, 0.0341). Midazolam was the most commonly administered sedative. Fewer patients required deep sedation using the faster CT scanner. CONCLUSIONS After installation of a dual-source dual-energy CT scanner, fewer patients required sedation to complete head CT in the pediatric ED. Faster image acquisition time decreased the need for deep sedation.
Collapse
Affiliation(s)
- Rebecca Kriss Burger
- From the Division of Emergency Medicine, Department of Pediatrics, Emory University + Pediatric Institute
| | - Janet Figueroa
- Department of Pediatrics, Emory University School of Medicine
| | - Ashishkumar K Parikh
- Division of Pediatric Radiology, Department of Pediatrics, Emory University + Pediatric Institute, Atlanta, GA
| | - Erica L Riedesel
- Division of Pediatric Radiology, Department of Pediatrics, Emory University + Pediatric Institute, Atlanta, GA
| |
Collapse
|
21
|
Lau KK, Troupis JM, Parsons D. Transformative radiology: Chest imaging is being re-defined. Respirology 2022; 27:815-817. [PMID: 36070934 DOI: 10.1111/resp.14358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 08/22/2022] [Indexed: 11/28/2022]
Affiliation(s)
- Kenneth K Lau
- Monash Imaging, Monash Health, Clayton, Victoria, Australia.,School of Clinical Sciences, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Victoria, Australia.,Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria, Australia
| | - John M Troupis
- Monash Imaging, Monash Health, Clayton, Victoria, Australia
| | - David Parsons
- Women's and Children's Hospital Adelaide Women's and Babies Division Ringgold Standard Institution-Respiratory and Sleep Medicine, North Adelaide, South Australia, Australia.,The University of Adelaide Ringgold Standard Institution-Robinson Research Institute, Adelaide, South Australia, Australia
| |
Collapse
|
22
|
Dual-source computed tomography protocols for the pediatric chest - scan optimization techniques. Pediatr Radiol 2022:10.1007/s00247-022-05468-7. [PMID: 35948645 PMCID: PMC9365683 DOI: 10.1007/s00247-022-05468-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 06/28/2022] [Accepted: 07/21/2022] [Indexed: 11/26/2022]
Abstract
The gold standard for pediatric chest imaging remains the CT scan. An ideal pediatric chest CT has the lowest radiation dose with the least motion degradation possible in a diagnostic scan. Because of the known inherent risks and costs of anesthesia, non-sedate options are preferred. Dual-source CTs are currently the fastest, lowest-dose CT scanners available, utilizing an ultra-high-pitch mode resulting in sub-second CTs. The dual-energy technique, available on dual-source CT scanners, gathers additional information such as pulmonary blood volume and includes relative contrast enhancement and metallic artifact reduction, features that are not available in high-pitch flash mode. In this article we discuss the benefits and tradeoffs of dual-source CT scan modes and tips on image optimization.
Collapse
|
23
|
Azour L, Ko JP, Toussie D, Gomez GV, Moore WH. Current imaging of PE and emerging techniques: is there a role for artificial intelligence? Clin Imaging 2022; 88:24-32. [DOI: 10.1016/j.clinimag.2022.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 04/23/2022] [Accepted: 05/02/2022] [Indexed: 11/26/2022]
|
24
|
Vaz A, Pedrazzani BM, Ledesma JA, Yagui A, Schelin HR. Effect of lateral decubitus acquisition in accuracy and lung severity estimation of chest computed tomography in children with suspected COVID-19. EINSTEIN-SAO PAULO 2022; 20:eAO0061. [PMID: 35894371 PMCID: PMC9299577 DOI: 10.31744/einstein_journal/2022ao0061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 05/18/2022] [Indexed: 11/05/2022] Open
|
25
|
Regmi PR, Amatya I, Paudel S, Kayastha P. Modern Paediatric Radiology: Meeting the Challenges in CT and MRI. JNMA J Nepal Med Assoc 2022; 60:661-663. [PMID: 36705198 PMCID: PMC9297347 DOI: 10.31729/jnma.7539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 06/25/2022] [Indexed: 01/31/2023] Open
Abstract
Radiology plays a very important part in the diagnosis, treatment, and follow-up of children. Computed tomography and magnetic resonance imaging are the two most crucial developments in the modern era. However, the two modalities have their challenges to overcome. Radiation dose is the most unwanted side effect of computed tomography scans while longer scan time along with sedation is a major disadvantage in children during magnetic resonance imaging. Paediatric-specific protocol selection and limiting the exposure to the area of interest aid in reducing the dose during computed tomography scans. Faster scan protocols and sequences can result in imaging without sedation in magnetic resonance imaging. Considering the radiation exposure, "as low as reasonably achievable" principle should be followed strictly in the paediatric population. In this article, possible ways for minimising the radiation dose in computed tomography, as well as effective, short, and sedation-free magnetic resonance imaging, are discussed. Keywords computed X-ray tomography; magnetic resonance imaging; pediatrics; radiation exposure; X-ray.
Collapse
Affiliation(s)
- Pradeep Raj Regmi
- Department of Radiology and Imaging, Tribhuvan University Teaching Hospital, Maharajgunj, Kathmandu, Nepal
| | - Isha Amatya
- Health Research Section, Nepal Health Research Council, Ramshahpath, Kathmandu, Nepal
| | - Sharma Paudel
- Department of Radiology and Imaging, Tribhuvan University Teaching Hospital, Maharajgunj, Kathmandu, Nepal,Correspondence: Dr Sharma Paudel, Department of Radiology and Imaging, Tribhuvan University Teaching Hospital, Maharajgunj, Kathmandu, Nepal. , Phone: +977-9841393486
| | - Prakash Kayastha
- Department of Radiology and Imaging, Tribhuvan University Teaching Hospital, Maharajgunj, Kathmandu, Nepal
| |
Collapse
|
26
|
Li Y, Liu X, Zhuang XH, Wang MJ, Song XF. Assessment of low-dose paranasal sinus CT imaging using a new deep learning image reconstruction technique in children compared to adaptive statistical iterative reconstruction V (ASiR-V). BMC Med Imaging 2022; 22:106. [PMID: 35658908 PMCID: PMC9164403 DOI: 10.1186/s12880-022-00834-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 05/27/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To compare the effects of deep learning image reconstruction (DLIR) and adaptive statistical iterative reconstruction V (ASiR-V) on image quality in low-dose computed tomography (CT) of paranasal sinuses in children. Methods Low-dose CT scans of the paranasal sinuses in 25 pediatric patients were retrospectively evaluated. The raw data were reconstructed with three levels of DLIR (high, H; medium, M; and low, L), filtered back projection (FBP), and ASiR-V (30% and 50%). Image noise was measured in both soft tissue and bone windows, and the signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of the images were calculated. Subjective image quality at the ethmoid sinus and nasal cavity levels of the six groups of reconstructed images was assessed by two doctors using a five-point Likert scale in a double-blind manner. Results The patients’ mean dose-length product and effective dose were 36.65 ± 2.44 mGy·cm and 0.17 ± 0.03 mSv, respectively. (1) Objective evaluation: 1. Soft tissue window: The difference among groups in each parameter was significant (P < 0.05). Pairwise comparisons showed that the H group’ s parameters were significantly better (P < 0.05) than those of the 50% post-ASiR-V group. 2. Bone window: No significant between-group differences were found in the noise of the petrous portion of the temporal bone or its SNR or in the noise of the pterygoid processes of the sphenoids or their SNRs (P > 0.05). Significant differences were observed in the background noise and CNR (P < 0.05). As the DLIR intensity increased, image noise decreased and the CNR improved. The H group exhibited the best image quality. (2) Subjective evaluation: Scores for images of the ethmoid sinuses were not significantly different among groups (P > 0.05). Scores for images of the nasal cavity were significantly different among groups (P < 0.05) and were ranked in descending order as follows: H, M, L, 50% post-ASiR-V, 30% post-ASiR-V, and FBP. Conclusion DLIR was superior to FBP and post-ASiR-V in low-dose CT scans of pediatric paranasal sinuses. At high intensity (H), DLIR provided the best reconstruction effects.
Collapse
|
27
|
Detection of Incidental Nonosseous Thoracic Pathology on State-of-the-Art Ultralow-Dose Protocol Computed Tomography in Pediatric Patients With Pectus Excavatum. J Comput Assist Tomogr 2022; 46:492-498. [DOI: 10.1097/rct.0000000000001285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
28
|
Rastogi V, Stefens SJM, Houwaart J, Verhagen HJM, de Bruin JL, van der Pluijm I, Essers J. Molecular Imaging of Aortic Aneurysm and Its Translational Power for Clinical Risk Assessment. Front Med (Lausanne) 2022; 9:814123. [PMID: 35492343 PMCID: PMC9051391 DOI: 10.3389/fmed.2022.814123] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 03/21/2022] [Indexed: 01/03/2023] Open
Abstract
Aortic aneurysms (AAs) are dilations of the aorta, that are often fatal upon rupture. Diagnostic radiological techniques such as ultrasound (US), magnetic resonance imaging (MRI), and computed tomography (CT) are currently used in clinical practice for early diagnosis as well as clinical follow-up for preemptive surgery of AA and prevention of rupture. However, the contemporary imaging-based risk prediction of aneurysm enlargement or life-threatening aneurysm-rupture remains limited as these are restricted to visual parameters which fail to provide a personalized risk assessment. Therefore, new insights into early diagnostic approaches to detect AA and therefore to prevent aneurysm-rupture are crucial. Multiple new techniques are developed to obtain a more accurate understanding of the biological processes and pathological alterations at a (micro)structural and molecular level of aortic degeneration. Advanced anatomical imaging combined with molecular imaging, such as molecular MRI, or positron emission tomography (PET)/CT provides novel diagnostic approaches for in vivo visualization of targeted biomarkers. This will aid in the understanding of aortic aneurysm disease pathogenesis and insight into the pathways involved, and will thus facilitate early diagnostic analysis of aneurysmal disease. In this study, we reviewed these molecular imaging modalities and their association with aneurysm growth and/or rupture risk and their limitations. Furthermore, we outline recent pre-clinical and clinical developments in molecular imaging of AA and provide future perspectives based on the advancements made within the field. Within the vastness of pre-clinical markers that have been studied in mice, molecular imaging targets such as elastin/collagen, albumin, matrix metalloproteinases and immune cells demonstrate promising results regarding rupture risk assessment within the pre-clinical setting. Subsequently, these markers hold potential as a future diagnosticum of clinical AA assessment. However currently, clinical translation of molecular imaging is still at the onset. Future human trials are required to assess the effectivity of potentially viable molecular markers with various imaging modalities for clinical rupture risk assessment.
Collapse
Affiliation(s)
- Vinamr Rastogi
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Sanne J. M. Stefens
- Department of Molecular Genetics, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Judith Houwaart
- Department of Molecular Genetics, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Hence J. M. Verhagen
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Jorg L. de Bruin
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Ingrid van der Pluijm
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
- Department of Molecular Genetics, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Jeroen Essers
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
- Department of Molecular Genetics, Erasmus University Medical Center, Rotterdam, Netherlands
- Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, Netherlands
- *Correspondence: Jeroen Essers
| |
Collapse
|
29
|
Tao S, Gong H, Michalak G, McCollough C, Leng S, Hu Y. Technical note: Evaluation of Artificial 120-kilovolt computed tomography images for radiation therapy applications. Med Phys 2022; 49:3683-3691. [PMID: 35394074 DOI: 10.1002/mp.15592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 02/25/2022] [Accepted: 02/28/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The purpose of this work is to evaluate the scaled CT number accuracy of an artificial 120 kV reconstruction technique based on phantom experiments in the context of radiation therapy planning. METHODS An abdomen-shaped electron density phantom was scanned on a clinical CT scanner capable of artificial 120 kV reconstruction using different tube potentials from 70 kV to 150 kV. A series of tissue equivalent phantom inserts (lung, adipose, breast, solid water, liver, inner bone, 30%/50% CaCO3, cortical bone) were placed inside the phantom. Images were reconstructed using a conventional quantitative reconstruction kernel as well as the artificial 120 kV reconstruction kernel. Scaled CT numbers of inserts were measured from images acquired at different kVs and compared with those acquired at 120 kV, which were deemed as the ground truth. The relative error was quantified as the percentage deviation of scaled CT numbers acquired at different tube potentials from their ground truth values acquired at 120 kV. RESULTS Scaled CT numbers measured from images reconstructed using the conventional reconstruction demonstrated a strong kV-dependence. The relative error in scaled CT number ranged from 0.6% (liver insert) to 31.1% (cortical bone insert). The artificial 120 kV reconstruction reduced the kV-dependence, especially for bone tissues. The relative error in scaled CT number was reduced to 0.4% (liver insert) and 2.6% (30% CaCO3 insert) using this technique. When tube potential selection was limited to the range of 90 kV to 150 kV, the relative error was further restrained to <1.2% for all tissue types. CONCLUSION Phantom results demonstrated that using the artificial 120 kV technique, it was feasible to acquire raw projection data at a desired tube potential and then reconstruct images with scaled CT numbers comparable to those obtained directly at 120 kV. In radiotherapy applications, this technique may allow optimization of tube potential without complicating clinical workflow by eliminating the necessity of maintaining multiple sets of CT calibration curves. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Shengzhen Tao
- Department of Radiology, Mayo Clinic, Jacksonville, FL, USA
| | - Hao Gong
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | | | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Yanle Hu
- Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, USA
| |
Collapse
|
30
|
Schooler GR, Cravero JP, Callahan MJ. Assessing and conveying risks and benefits of imaging in neonates using ionizing radiation and sedation/anesthesia. Pediatr Radiol 2022; 52:616-621. [PMID: 34283256 DOI: 10.1007/s00247-021-05138-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 05/24/2021] [Accepted: 06/14/2021] [Indexed: 12/15/2022]
Abstract
Neonates represent a unique subset of the pediatric population that requires special attention and careful thought when implementing advanced cross-sectional imaging with CT or MRI. The ionizing radiation associated with CT and the sedation/anesthesia occasionally required for MRI present risks that must be balanced against the perceived benefit of the imaging examination in the unique and particularly susceptible neonatal population. We review the perceived risks of ionizing radiation and the more concrete risks of sedation/anesthesia in term and preterm neonates in the context of an imaging paradigm. When the expected diagnostic yield from CT and MRI is similar, and sedation is required for MRI but not for CT, CT likely has the higher benefit-to-risk ratio in the neonate. However, despite the risks, the most appropriate imaging modality should always be chosen after thoughtful consideration is given to each unique patient and informed discussions including radiology, anesthesia, neonatology and the parents/caregivers are pursued.
Collapse
Affiliation(s)
- Gary R Schooler
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX, 75390, USA.
| | - Joseph P Cravero
- Department of Anesthesiology, Critical Care, and Pain Medicine, Harvard Medical School, Boston, MA, USA
| | - Michael J Callahan
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
31
|
Tajaldeen A, Kheiralla OAM, Alghamdi SS, Alsleem H, Al-Othman A, Abuelhia E, Aljondi R. Evaluation of Pediatric Imaging Modalities Practices of Radiologists and Technologists: A Survey-Based Study. J Multidiscip Healthc 2022; 15:443-453. [PMID: 35280855 PMCID: PMC8906869 DOI: 10.2147/jmdh.s351696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 02/17/2022] [Indexed: 11/23/2022] Open
Affiliation(s)
- Abdulrahman Tajaldeen
- Department of Radiological Sciences, College of Applied Medical Science, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
- Correspondence: Abdulrahman Tajaldeen, Email
| | - Osama A Mabrouk Kheiralla
- Department of Radiological Sciences, College of Applied Medical Science, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Salem Saeed Alghamdi
- Department of Applied Radiologic Technology, College of Applied Medical Sciences, University of Jeddah, Jeddah, Saudi Arabia
| | - Haney Alsleem
- Department of Radiological Sciences, College of Applied Medical Science, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Abdullah Al-Othman
- Radiology Department, King Fahad University Hospital, Alkhobar, Saudi Arabia
| | - Elfatih Abuelhia
- Department of Radiological Sciences, College of Applied Medical Science, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Rowa Aljondi
- Department of Applied Radiologic Technology, College of Applied Medical Sciences, University of Jeddah, Jeddah, Saudi Arabia
| |
Collapse
|
32
|
Malone LJ, Morin CE, Browne LP. Coronary computed tomography angiography in children. Pediatr Radiol 2022; 52:2498-2509. [PMID: 34734316 PMCID: PMC8566193 DOI: 10.1007/s00247-021-05209-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 08/16/2021] [Accepted: 09/10/2021] [Indexed: 12/17/2022]
Abstract
Imaging the coronary arteries of children, with their faster heart rates, small vessel size and common inability to lie still or breath-hold, has been a major challenge. With numerous advances in technology, CT examinations can now be performed quickly, often with children free-breathing and with much lower radiation doses than previously. This has led to increased use in children. Care must be taken with technique and choice of electrocardiogram (ECG)-gating technique to obtain adequate imaging for a diagnosis while keeping radiation dose as low as reasonably achievable (ALARA). In this paper, we discuss techniques and tips for CT imaging of the coronary arteries in children, including use of dual-source- and ultrawide-detector CT scanners.
Collapse
Affiliation(s)
- LaDonna J Malone
- Department of Radiology, University of Colorado, Aurora, CO, USA.
- Department of Radiology, Children's Hospital of Colorado, 13123 E. 16th Ave., B125, Aurora, CO, 80045, USA.
| | - Cara E Morin
- Department of Diagnostic Imaging, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Lorna P Browne
- Department of Radiology, University of Colorado, Aurora, CO, USA
- Department of Radiology, Children's Hospital of Colorado, 13123 E. 16th Ave., B125, Aurora, CO, 80045, USA
| |
Collapse
|
33
|
Ji H, You SK, Lee JE, Lee SM, Cho HH, Ohm JY. Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels. JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY 2022; 83:669-679. [PMID: 36238515 PMCID: PMC9514522 DOI: 10.3348/jksr.2021.0003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Revised: 05/04/2021] [Accepted: 06/30/2021] [Indexed: 11/15/2022]
Abstract
Purpose Materials and Methods Results Conclusion
Collapse
Affiliation(s)
- Hye Ji
- Department of Radiology, Chungnam National University Hospital, Daejeon, Korea
| | - Sun Kyoung You
- Department of Radiology, Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon, Korea
| | - Jeong Eun Lee
- Department of Radiology, Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon, Korea
| | - So Mi Lee
- Department of Radiology, School of Medicine, Kyungpook National University, Kyungpook National University Chilgok Hospital, Daegu, Korea
| | - Hyun-Hae Cho
- Department of Radiology, Ewha Womans University Mokdong Hospital, Seoul, Korea
| | - Joon Young Ohm
- Department of Radiology, Chungnam National University Hospital, Daejeon, Korea
| |
Collapse
|
34
|
Ahmed HM, Borg M, Saleem AEA, Ragab A. Multi-detector computed tomography in traumatic abdominal lesions: value and radiation control. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2021. [DOI: 10.1186/s43055-021-00581-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background, The context
A prospective study was conducted involving 81 patients (mean age, 20.79 years) with abdominal trauma who underwent ultrasonography and post-contrast CT on MDCT scanner. The total DLP for each patient was reviewed, and the effective dose was calculated. Purpose of the study to: explore the role of MDCT in assessing traumatic abdominal lesions, demonstrate radiation dose delivered by MDCT, and describe specific CT technical features to minimize radiation.
Results
The spleen was the most commonly injured organ (49.4%) followed by liver (39.5%) and kidney (24.7%). Pancreatic injury occurred in seven patients, whereas only two patients had intestinal injuries. One patient had adrenal injury. Minimal, mild and moderate free intra-peritoneal fluid collection was detected in 21 (25.9%), 47 (58%) and 10 (12.3%) patients, respectively. Only three (3.7%) patients had no collection. One patient had active uncontrolled bleeding and died. Radiation dose was below the detrimental level (calculated effective dose), with optimal image quality.
Conclusions
MDCT is sensitive to all types of traumatic abdominal lesions. Not only in determining the injury, but also in its grading. MDCT has affected the treatment directions, spotting a focus on conservative treatment by raising the diagnostic confidence.
FAST cannot be the sole imaging modality. The individual radiation risk is small but real. Advancements in medical imaging reduce radiation risk.
Collapse
|
35
|
Elbahlawan L, McArthur J, Morin CE, Abdelhafeez H, McCarville MB, Ruiz RE, Srinivasan S, Qudeimat A. Pulmonary Complications in Children Following Hematopoietic Cell Transplantation: A Case Report and Review of the Diagnostic Approach. Front Oncol 2021; 11:772411. [PMID: 34820335 PMCID: PMC8606675 DOI: 10.3389/fonc.2021.772411] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 10/20/2021] [Indexed: 12/24/2022] Open
Abstract
Pulmonary complications are common in children following hematopoietic cell transplantation (HCT) and contribute to their morbidity and mortality. Early diagnosis is essential for management and prevention of progression of lung injury and damage. In many cases, diagnosis can be challenging and may require diagnostic imaging and more invasive testing such as bronchoscopy and lung biopsy. We report the case of a 12-year-old girl who developed recurrent episodes of acute respiratory failure requiring intensive care unit admission in the post-HCT phase and describe the diagnostic and multidisciplinary approach for her management. In addition, we review the diagnostic approach of pulmonary complications post-HCT and highlight the utility and risks of bronchoscopy and lung biopsy in these children.
Collapse
Affiliation(s)
- Lama Elbahlawan
- Division of Critical Care Medicine, St. Jude Children's Research Hospital, Memphis, TN, United States
| | - Jenny McArthur
- Division of Critical Care Medicine, St. Jude Children's Research Hospital, Memphis, TN, United States
| | - Cara E Morin
- Department of Diagnostic Imaging, St. Jude Children's Research Hospital, Memphis, TN, United States
| | - Hafeez Abdelhafeez
- Department of Surgery, St. Jude Children's Research Hospital, Memphis, TN, United States
| | - M Beth McCarville
- Department of Diagnostic Imaging, St. Jude Children's Research Hospital, Memphis, TN, United States
| | - Robert E Ruiz
- Department of Pathology, St. Jude Children's Research Hospital, Memphis, TN, United States
| | - Saumini Srinivasan
- Division of Pulmonary, University of TN Health Science Center (UTHSC), Memphis, TN, United States
| | - Amr Qudeimat
- Department of Bone Marrow Transplant and Cellular Therapy, St. Jude Children's Research Hospital, Memphis, TN, United States
| |
Collapse
|
36
|
Prabhu SP. 3D Modeling and Advanced Visualization of the Pediatric Brain, Neck, and Spine. Magn Reson Imaging Clin N Am 2021; 29:655-666. [PMID: 34717852 DOI: 10.1016/j.mric.2021.06.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
The ready availability of advanced visualization tools on picture archiving and communication systems workstations or even standard laptops through server-based or cloud-based solutions has enabled greater adoption of these techniques. We describe how radiologists can tailor imaging techniques for optimal 3D reconstructions provide a brief overview of the standard and newer "on-screen" techniques. We describe the process of creating 3D printed models for surgical simulation and education, with examples from the authors' institution and the existing literature. Finally, the review highlights current uses and potential future use cases for virtual reality and augmented reality applications in a pediatric neuroimaging setting.
Collapse
Affiliation(s)
- Sanjay P Prabhu
- Neuroradiology Division, Department of Radiology, Boston Children's Hospital, Harvard Medical School, SIMPeds3D Print, 300 Longwood Avenue, Boston, MA 02115, USA.
| |
Collapse
|
37
|
Hodgson KE, Larkin EA, Aznar MC, Vasquez Osorio E. Dual-energy computed tomography: Survey results on current uses and barriers to further implementation. Br J Radiol 2021; 94:20210565. [PMID: 34672691 DOI: 10.1259/bjr.20210565] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To gauge the current availability of dual-energy computed tomography (DECT) scanners in the UK, establish available technologies, look broadly at current clinical uses in adults and paediatrics, and identify barriers to implementation and potential ways to increase use. METHODS A survey was distributed amongst 10 radiology departments and shared on two national professional co-operation mail bases; the survey ran from 20th July to 9th December 2020. It explored current DECT utilisation in adults and paediatrics as well as barriers to use and suggestions to overcome those barriers. RESULTS The survey demonstrated DECT availability on 39 (40%) of the 98 CT scanners, but there was limited clinical use in adults and paediatrics. Eighteen (72%) of the 25 respondents had access to at least one DECT scanner, with 14 (56%) having adult DECT protocols in clinical use; <10% head examinations and <50% for other anatomical areas. Only two (8%) respondents had DECT paediatric protocols in clinical use; <10% examinations for all anatomical areas.The main barriers to implementation identified were lack of experience with DECT (8 (44%) users (adult) and 10 (56%) users (paediatric)) and no clinical protocols available (6 (33%) users (adult and paediatric)).Understanding DECT benefits and establishing suitable protocols were the most popular suggestions for increased implementation (10 (40%) of 25 respondents). CONCLUSION DECT scanners are available, but clinical use is limited for both adults and paediatrics. The main barriers identified were lack of experience with DECT and the availability of suitable protocols. Further work identified to help implementation included better education on the benefits of DECT, provision of clinical protocols and ensuring a multidisciplinary approach. ADVANCES IN KNOWLEDGE Barriers to implementation of clinical DECT protocols were identified, together with potential solutions to overcome these and enable further implementation.
Collapse
Affiliation(s)
| | - Elizabeth A Larkin
- University Hospitals Birmingham NHS Foundation Trust, Birmingham, England, United Kingdom
| | - Marianne C Aznar
- Division of Cancer Science, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, England, United Kingdom.,The Christie NHS Foundation Trust, Manchester, England, United Kingdom
| | - Eliana Vasquez Osorio
- Division of Cancer Science, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, England, United Kingdom.,The Christie NHS Foundation Trust, Manchester, England, United Kingdom
| |
Collapse
|
38
|
Zhang L, Li L, Feng G, Fan T, Jiang H, Wang Z. Advances in CT Techniques in Vascular Calcification. Front Cardiovasc Med 2021; 8:716822. [PMID: 34660718 PMCID: PMC8511450 DOI: 10.3389/fcvm.2021.716822] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Accepted: 08/30/2021] [Indexed: 12/17/2022] Open
Abstract
Vascular calcification, a common pathological phenomenon in atherosclerosis, diabetes, hypertension, and other diseases, increases the incidence and mortality of cardiovascular diseases. Therefore, the prevention and detection of vascular calcification play an important role. At present, various techniques have been applied to the analysis of vascular calcification, but clinical examination mainly depends on non-invasive and invasive imaging methods to detect and quantify. Computed tomography (CT), as a commonly used clinical examination method, can analyze vascular calcification. In recent years, with the development of technology, in addition to traditional CT, some emerging types of CT, such as dual-energy CT and micro CT, have emerged for vascular imaging and providing anatomical information for calcification. This review focuses on the latest application of various CT techniques in vascular calcification.
Collapse
Affiliation(s)
- Lijie Zhang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Lihua Li
- Department of Pathology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Guoquan Feng
- Department of Radiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Tingpan Fan
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Han Jiang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Zhongqun Wang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| |
Collapse
|
39
|
Baş S, Alkara U, Aliyev B. Evaluation of complex congenital heart disease with prospective ECG-gated cardiac CT in a single heartbeat at low tube voltage (70 kV) and adaptive statistical iterative reconstruction in infants: a single center experience. Int J Cardiovasc Imaging 2021; 38:413-422. [PMID: 34487310 DOI: 10.1007/s10554-021-02390-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 08/21/2021] [Indexed: 10/20/2022]
Abstract
The purpose of this study is to evaluate the radiation dose, image quality, and diagnostic accuracy of prospective ECG-gated cardiac CT at 70 kV and adaptive statistical iterative reconstruction (ASIR), with a single source, 512 slice MDCT in the diagnosis of complex congenital heart disease in infants. We retrospectively evaluated 47 infants (ages 1 day to 353 days) with prospective ECG-gated cardiac CT that was performed on a single source 512 slice CT at low tube voltage (70 kV) using a wide detector aperture, adaptive statistical iterative reconstruction algorithm (ASIR), and specific reconstruction software reducing coronary motion artifacts (SnapShot Freeze). All cardiac images were obtained during the first pass of contrast material through the anatomic structures of interest and the targets for the center of the acquisition window were set 45% of the R-R interval during one cardiac cycle without sedation and breath-hold. The median effective dose measured in our study was 0.64 ± 0.16 mSv. The average subjective overall image quality score was 4.34 ± 0.31 (range 3-5). For the determination of objective image quality, Mean Noise (HU), SNR, and CNR values emerged as 20.8, 28.7(for pulmonary artery), and 27.1, respectively. Diagnostic accuracy was 100% for the main purposes for the main clinical indication. During cardiac CT examination, pathologies in addition to cardiac anomalies were found in 9/47 of cases (7 severe airway obstructions,1 posterior diaphragmatic hernia, 1 vertebral anomaly). Prospective ECG-gated cardiac CT scan at 70 kV and ASIR in infants with complex CHD provides low radiation dose (submillisievert) in a single heartbeat with a good objective and subjective image quality. It also provides important benefits in the diagnosis of additional pathology.
Collapse
Affiliation(s)
- Serap Baş
- Gaziosmanpaşa Hospital, Department of Radiology, Istanbul Yeni Yuzyil University, Merkez Mah. Çukurçeşme Cad. No:51 Gaziosmapaşa, 34245, Istanbul, Turkey.
| | - Utku Alkara
- Gaziosmanpaşa Hospital, Department of Radiology, Istanbul Yeni Yuzyil University, Merkez Mah. Çukurçeşme Cad. No:51 Gaziosmapaşa, 34245, Istanbul, Turkey
| | - Bahruz Aliyev
- Gaziosmanpaşa Hospital, Department of Pediatric Cardiology, Istanbul Yeni Yuzyil University, Istanbul, Turkey
| |
Collapse
|
40
|
Wang X, MacDougall RD, Chen P, Bouman CA, Warfield SK. Physics-based iterative reconstruction for dual-source and flying focal spot computed tomography. Med Phys 2021; 48:3595-3613. [PMID: 33982297 DOI: 10.1002/mp.14941] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 04/08/2021] [Accepted: 04/16/2021] [Indexed: 12/21/2022] Open
Abstract
PURPOSE For single-source helical Computed Tomography (CT), both Filtered-Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual-source CT with flying focal spot (DS-FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics-based iterative reconstruction method for DS-FFS CT and assess its image quality. METHODS Our algorithm uses precise physics models to reconstruct from the native cone-beam geometry and interleaved dual-source helical trajectory of a DS-FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x-rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x-ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. RESULTS We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS-FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task-Based Modulation Transfer Function (MTFtask ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. CONCLUSIONS By modeling a precise geometry and avoiding data rebinning or interpolation, our physics-based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.
Collapse
Affiliation(s)
- Xiao Wang
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Robert D MacDougall
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Peng Chen
- National Institute of Advanced Industrial Science and Technology, Tokyo, Japan.,RIKEN Center for Computational Science, Kobe, Hyogo, Japan
| | - Charles A Bouman
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Simon K Warfield
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA, 02115, USA
| |
Collapse
|
41
|
Siegel MJ, Bhalla S, Cullinane M. Dual-Energy CT Material Decomposition in Pediatric Thoracic Oncology. Radiol Imaging Cancer 2021; 3:e200097. [PMID: 33778757 DOI: 10.1148/rycan.2021200097] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 08/22/2020] [Accepted: 08/27/2020] [Indexed: 11/11/2022]
Abstract
Technical advances in CT have enabled implementation of dual-energy CT into routine clinical practice. By acquiring images at two different energy spectra, dual-energy CT enables material decomposition, allowing generation of material- and energy-specific images. Material-specific images include virtual nonenhanced images and iodine-specific images (iodine maps). Energy-specific images include virtual monoenergetic images. The reconstructed images can provide unique qualitative and quantitative information about tissue composition and contrast media distribution. In thoracic oncologic imaging, dual-energy CT provides advantages in characterization of thoracic malignancies and lung nodules, determination of extent of disease, and assessment of response to therapy. An especially important feature in children is that dual-energy CT does not come at a higher radiation exposure. Keywords: CT, CT-Quantitative, Lung, Mediastinum, Neoplasms-Primary, Pediatrics, Thorax, Treatment Effects © RSNA, 2021.
Collapse
Affiliation(s)
- Marilyn J Siegel
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, St Louis, MO 63110 (M.J.S., S.B.); and Siemens Healthineers, Malvern, Pa (M.C.)
| | - Sanjeev Bhalla
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, St Louis, MO 63110 (M.J.S., S.B.); and Siemens Healthineers, Malvern, Pa (M.C.)
| | - Mike Cullinane
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, St Louis, MO 63110 (M.J.S., S.B.); and Siemens Healthineers, Malvern, Pa (M.C.)
| |
Collapse
|
42
|
Pasqual E, Boussin F, Bazyka D, Nordenskjold A, Yamada M, Ozasa K, Pazzaglia S, Roy L, Thierry-Chef I, de Vathaire F, Benotmane MA, Cardis E. Cognitive effects of low dose of ionizing radiation - Lessons learned and research gaps from epidemiological and biological studies. ENVIRONMENT INTERNATIONAL 2021; 147:106295. [PMID: 33341586 DOI: 10.1016/j.envint.2020.106295] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 10/02/2020] [Accepted: 10/20/2020] [Indexed: 06/12/2023]
Abstract
The last decades have seen increased concern about the possible effects of low to moderate doses of ionizing radiation (IR) exposure on cognitive function. An interdisciplinary group of experts (biologists, epidemiologists, dosimetrists and clinicians) in this field gathered together in the framework of the European MELODI workshop on non-cancer effects of IR to summarise the state of knowledge on the topic and elaborate research recommendations for future studies in this area. Overall, there is evidence of cognitive effects from low IR doses both from biology and epidemiology, though a better characterization of effects and understanding of mechanisms is needed. There is a need to better describe the specific cognitive function or diseases that may be affected by radiation exposure. Such cognitive deficit characterization should consider the human life span, as effects might differ with age at exposure and at outcome assessment. Measurements of biomarkers, including imaging, will likely help our understanding on the mechanism of cognitive-related radiation induced deficit. The identification of loci of individual genetic susceptibility and the study of gene expression may help identify individuals at higher risk. The mechanisms behind the radiation induced cognitive effects are not clear and are likely to involve several biological pathways and different cell types. Well conducted research in large epidemiological cohorts and experimental studies in appropriate animal models are needed to improve the understanding of radiation-induced cognitive effects. Results may then be translated into recommendations for clinical radiation oncology and imaging decision making processes.
Collapse
Affiliation(s)
- Elisa Pasqual
- Barcelona Institute for Global Health (ISGlobal), Campus Mar, Barcelona Biomedical Research Park (PRBB), Dr Aiguader 88, 08003 Barcelona, Spain; University Pompeu Fabra, Barcelona, Spain; Consortium for Biomedical Research in Epidemiology & Public Health (CIBERESP), Carlos III Institute of Health, Madrid, Spain.
| | - François Boussin
- Université de Paris and Université Paris-Saclay, Inserm, LRP/iRCM/IBFJ CEA, UMR Stabilité Génétique Cellules Souches et Radiations, F-92265 Fontenay-aux-Roses, France
| | - Dimitry Bazyka
- National Research Center for Radiation Medicine, 53 Illenko str., Kyiv, Ukraine
| | - Arvid Nordenskjold
- Department of Clinical Neuroscience, Division of Neurology, Karolinska Institutet, Stockholm, Sweden
| | - Michiko Yamada
- Department of Clinical Studies, Radiation Effects Research Foundation, Hiroshima, Japan
| | - Kotaro Ozasa
- Department of Epidemiology, Radiation Effects Research Foundation, Hiroshima, Japan
| | - Simonetta Pazzaglia
- Laboratory of Biomedical Technologies, ENEA CR-Casaccia, Via Anguillarese 301, 00123 Rome, Italy
| | - Laurence Roy
- Department for Research on the Biological and Health Effects of Ionising Radiation. Institut of Radiation Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Isabelle Thierry-Chef
- Barcelona Institute for Global Health (ISGlobal), Campus Mar, Barcelona Biomedical Research Park (PRBB), Dr Aiguader 88, 08003 Barcelona, Spain; University Pompeu Fabra, Barcelona, Spain; Consortium for Biomedical Research in Epidemiology & Public Health (CIBERESP), Carlos III Institute of Health, Madrid, Spain
| | - Florent de Vathaire
- Radiation Epidemiology Teams, INSERM Unit 1018, University Paris Saclay, Gustave Roussy, 94800 Villejuif, France
| | | | - Elisabeth Cardis
- Barcelona Institute for Global Health (ISGlobal), Campus Mar, Barcelona Biomedical Research Park (PRBB), Dr Aiguader 88, 08003 Barcelona, Spain; University Pompeu Fabra, Barcelona, Spain; Consortium for Biomedical Research in Epidemiology & Public Health (CIBERESP), Carlos III Institute of Health, Madrid, Spain
| |
Collapse
|
43
|
Schmidt B, Flohr T. Principles and applications of dual source CT. Phys Med 2020; 79:36-46. [PMID: 33115699 DOI: 10.1016/j.ejmp.2020.10.014] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 10/12/2020] [Accepted: 10/14/2020] [Indexed: 01/03/2023] Open
Abstract
This article describes the technical principles and clinical applications of dual source CT. A dual source CT (DSCT) is a CT system with two x-ray tubes and two detectors at an angle of approximately 90°. Both measurement systems acquire CT scan data simultaneously at the same anatomical level of the patient (same z-position). DSCT provides temporal resolution of approximately a quarter of the gantry rotation time for cardiac, cardio-thoracic and pediatric imaging. Successful imaging of the heart and the coronary arteries at high and variable heart rates has been demonstrated. DSCT systems can be operated at twice the spiral pitch of single source CT systems (up to pitch 3.2). The resulting high table speed is beneficial for pediatric applications and fast CT angiographic scans, e. g. of the aorta or the extremities. Operating both X-ray tubes at different tube potential (kV) enables the acquisition of dual energy data and the corresponding applications such as monoenergetic imaging and computation of material maps. Spectral separation can be improved by different filtration of the X-ray beams of both X-ray tubes. As a downside, DSCT systems have to cope with some challenges, among them the limited size of the second measurement system, and cross-scattered radiation.
Collapse
Affiliation(s)
- Bernhard Schmidt
- Siemens Healthcare GmbH, Computed Tomography, Siemensstr. 3, 91301 Forchheim, Germany.
| | - Thomas Flohr
- Siemens Healthcare GmbH, Computed Tomography, Siemensstr. 3, 91301 Forchheim, Germany
| |
Collapse
|
44
|
Abstract
OBJECTIVE. Pediatric CT angiography (CTA) presents unique challenges compared with adult CTA. Because of the ionizing radiation exposure, CTA should be used judiciously in children. The pearls offered here are observations gleaned from the authors' experience in the use of pediatric CTA. We also present some potential follies to be avoided. CONCLUSION. Understanding the underlying principles and paying meticulous attention to detail can substantially optimize dose and improve the diagnostic quality of pediatric CTA.
Collapse
|
45
|
Kang EJ. Clinical Applications of Wide-Detector CT Scanners for Cardiothoracic Imaging: An Update. Korean J Radiol 2020; 20:1583-1596. [PMID: 31854147 PMCID: PMC6923215 DOI: 10.3348/kjr.2019.0327] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 07/23/2019] [Indexed: 12/21/2022] Open
Abstract
Technical developments in multidetector computed tomography (CT) have increased the number of detector rows on the z-axis, and 16-cm wide-area-coverage CT scanners have enabled volumetric scanning of the entire heart. Beyond coronary arterial imaging, such innovations offer several advantages during clinical imaging in the cardiothoracic area. The wide-detector CT scanner markedly reduces the image acquisition time to less than 1 second for coronary CT angiography, thereby decreasing the volume of contrast material and radiation dose required for the examination. It also eliminates stair-step artifacts, allowing robust improvements in myocardial function and perfusion imaging. Additionally, new imaging techniques for the cardiothoracic area, including subtraction imaging and free-breathing scans, have been developed and further improved by using the wide-detector CT scanner. This article investigates the technical developments in wide-detector CT scanners, summarizes their clinical applications in the cardiothoracic area, and provides a review of the recent literature.
Collapse
Affiliation(s)
- Eun Ju Kang
- Department of Radiology, College of Medicine, Dong-A University, Busan, Korea.
| |
Collapse
|
46
|
Kharita MH, Al-Naemi H, Arru C, Omar AJ, Aly A, Tsalafoutas I, Alkhazzam S, Singh R, Kalra MK. Relation between age and CT radiation doses: Dose trends in 705 pediatric head CT. Eur J Radiol 2020; 130:109138. [PMID: 32619755 DOI: 10.1016/j.ejrad.2020.109138] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 05/18/2020] [Accepted: 06/12/2020] [Indexed: 11/24/2022]
Abstract
PURPOSE To evaluate the relationship between patient age and radiation doses associated with routine pediatric head CT performed with automatic tube potential selection and tube current modulation techniques. METHODS We obtained patient demographics, scan parameters, and radiation dose descriptors (CT dose index volume -CTDIvol and dose length product -DLP) associated with consecutive routine head CT in 705 children (mean age 6.9 ± 5 years). Children were scanned on one of the three multidetector-row CTs (64-128 slices, Siemens) over 6 months period in a tertiary hospital. All head CT exams were performed in helical scan mode using automatic tube potential selection (Care kV) and automatic tube current modulation (Care Dose 4D) techniques. The information was obtained from a radiation dose monitoring software. Data were analyzed using linear correlation and analysis of variance. RESULTS Most age-wise median CTDIvol (9-27 mGy; 703/705 pediatric head CT, >99 %) from our institution were lower than the European Diagnostic Reference Levels (EDRL, CTDIvol 24-50 mGy) but median DLP (151-586 mGy cm) from 201/705 children (28 %) was higher than the EDRL (DLP 300-650 mGy cm). Unlike the age-stratified EDRL, a combination of automatic tube potential selection and tube current modulation for pediatric head results in a significant linear correlation between radiation doses and patient age (r2 = 0.66, p < 0.001). CONCLUSIONS Radiation doses for head CT change linearly with children's age. Despite lower CTDIvol and DLP for most children, longer scan length resulted in higher DLP for some pediatric head CT compared to the corresponding EDRL; this result underscores the need to promote clear guidelines for technologists operating CT.
Collapse
Affiliation(s)
| | | | - Chiara Arru
- Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
| | | | - Antar Aly
- Hamad Medical Corporation, Doha, Qatar
| | | | | | - Ramandeep Singh
- Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Mannudeep K Kalra
- Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
47
|
Rindler RS, Allen JW, Barrow JW, Pradilla G, Barrow DL. Neuroimaging of Intracerebral Hemorrhage. Neurosurgery 2020; 86:E414-E423. [DOI: 10.1093/neuros/nyaa029] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2019] [Accepted: 12/28/2019] [Indexed: 02/05/2023] Open
Abstract
AbstractIntracerebral hemorrhage (ICH) accounts for 10% to 20% of strokes worldwide and is associated with high morbidity and mortality rates. Neuroimaging is indispensable for rapid diagnosis of ICH and identification of the underlying etiology, thus facilitating triage and appropriate treatment of patients. The most common neuroimaging modalities include noncontrast computed tomography (CT), CT angiography (CTA), digital subtraction angiography, and magnetic resonance imaging (MRI). The strengths and disadvantages of each modality will be reviewed. Novel technologies such as dual-energy CT/CTA, rapid MRI techniques, near-infrared spectroscopy, and automated ICH detection hold promise for faster pre- and in-hospital ICH diagnosis that may impact patient management.
Collapse
Affiliation(s)
- Rima S Rindler
- Department of Neurosurgery, Emory University Hospital, Atlanta, Georgia
| | - Jason W Allen
- Department of Radiology and Imaging Sciences, Emory University Hospital, Atlanta, Georgia
| | - Jack W Barrow
- Mercer University School of Medicine, Savannah, Georgia
| | - Gustavo Pradilla
- Department of Neurosurgery, Emory University Hospital, Atlanta, Georgia
| | - Daniel L Barrow
- Department of Neurosurgery, Emory University Hospital, Atlanta, Georgia
| |
Collapse
|
48
|
Szczykutowicz TP. Invited Commentary on “Advanced CT Techniques for Decreasing Radiation Dose, Reducing Sedation Requirements, and Optimizing Image Quality in Children”. Radiographics 2019; 39:727-728. [DOI: 10.1148/rg.2019180211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Timothy P. Szczykutowicz
- Departments of Radiology, Medical Physics, and Biomedical Engineering, University of Wisconsin–Madison Madison, Wisconsin
| |
Collapse
|