1
|
Badell JS, Cottom JM, Verdoni T. Approach to patients with metal allergies in foot and ankle surgery. J Foot Ankle Surg 2025; 64:302-308. [PMID: 39765305 DOI: 10.1053/j.jfas.2024.12.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2024] [Revised: 12/08/2024] [Accepted: 12/30/2024] [Indexed: 01/18/2025]
Abstract
Metal allergies in surgery are often underreported and under diagnosed. Oftentimes, the symptoms of metal allergy closely resemble those of infection and the protocol is removal of the offending implant. Identification of metal allergies in the preoperative workup is imperative to provide the best patient care and outcomes. The purpose of this report is to present considerations to approach to both preoperative and postoperative identification of patients with metal allergies. Utilizing published algorithms for total knee arthroplasty (TKA) and the author's experience, considerations for both preoperative and postoperative metal allergy have been developed to help the foot and ankle surgeon with the complicated task of addressing patients with metal allergies. To date, the authors have utilized this guidelines for total ankle arthroplasty, ankle fracture open reduction internal fixation, and first metatarsophalangeal joint arthrodesis. While literature has been published with metal allergy algorithms for total knee arthroplasty, this is the first of its kind for adaptation to foot and ankle surgery in general to the author's knowledge. To date, the authors have favorable outcomes utilizing these approaches to not only guide patient care but to help prevent future complications or address them if they present. With a thorough patient history, identification of metal allergies, a multidisciplinary approach and pre-operative planning, good outcomes can be achieved.
Collapse
Affiliation(s)
- Jay S Badell
- Fellowship Trained Foot and Ankle Surgeon, Hancock Orthopedics, Hancock Health, 801 N. State St, Suite 2100, Greenfield, IN, 46140, USA.
| | - James M Cottom
- Fellowship Trained Foot and Ankle Surgeon, Director, Florida Orthopedic Foot & Ankle Center Fellowship, 5741 Bee Ridge Rd #490, Sarasota, FL, 34233, USA.
| | - Tyler Verdoni
- Surgical Fellow, Florida Orthopedic Foot & Ankle Center Fellowship, 5741 Bee Ridge Rd #490, Sarasota, FL 34233, USA.
| |
Collapse
|
2
|
Kurtz MA, Hallab NJ, Rainey JP, Pelt CE, Mihalko WM, Piuzzi NS, Mont MA, Spece H, Kurtz SM. Metal Release in Total Knee Arthroplasty: A Review of Mechanisms, Adverse Local Tissue Reactions, and Biological Effects. J Arthroplasty 2025:S0883-5403(25)00237-2. [PMID: 40090503 DOI: 10.1016/j.arth.2025.03.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2024] [Revised: 03/06/2025] [Accepted: 03/07/2025] [Indexed: 03/18/2025] Open
Abstract
Compared to the hip, where investigators associate metal release with adverse local tissue reactions (ALTRs), metal-related complications in total knee arthroplasty (TKA) remain controversial and underexplored. Primary TKA systems use monobloc components, limiting corrosion and subsequent concerns. However, like the joints they replace, metal components degrade in vivo. In this narrative review, we aimed to summarize clinically relevant knowledge on metal release within the context of TKA for practicing orthopaedic surgeons. We asked: do ALTRs associated with metal release occur in the knee, and if so, to what extent? To answer this research question, we identified in vivo degradation mechanisms, including wear, mechanically assisted crevice corrosion, and electrocautery damage. Next, we synthesized case reports and retrospective clinical studies documenting ALTRs in primary and revision TKAs. Then, we reviewed the biological response to cobalt chrome debris, focusing on genotoxicity, immune responses, and hypersensitivity. While clinical evidence suggests that patients rarely experience severe biological reactions like pseudotumors, ALTRs associated with metal release can and do occur following TKA. To overcome knowledge gaps related to the prevalence of ALTR in TKA, prospective clinical trials are needed.
Collapse
Affiliation(s)
- Michael A Kurtz
- Drexel University Implant Research Core, Philadelphia, Pennsylvania
| | - Nadim J Hallab
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Joshua P Rainey
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah
| | - Cristopher E Pelt
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah
| | - William M Mihalko
- University of Tennessee Health Science Center, Campbell Clinic Orthopaedics, Memphis, Tennessee
| | - Nicolas S Piuzzi
- Department of Orthopedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Michael A Mont
- The Rubin Institute, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Hannah Spece
- Drexel University Implant Research Core, Philadelphia, Pennsylvania
| | - Steven M Kurtz
- Drexel University Implant Research Core, Philadelphia, Pennsylvania
| |
Collapse
|
3
|
Pacheco KA, Thyssen JP. Contact Dermatitis From Biomedical Devices, Implants, and Metals-Trouble From Within. THE JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY. IN PRACTICE 2024; 12:2280-2295. [PMID: 39067854 DOI: 10.1016/j.jaip.2024.07.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 07/22/2024] [Accepted: 07/22/2024] [Indexed: 07/30/2024]
Abstract
Allergic contact dermatitis is characterized by its appearance of red, raised and infiltrated, scaling or scabbed skin and intense pruritus, and distinguished from irritant contact dermatitis by its specific immune process and histopathology. Many contact allergens are low-molecular- weight chemicals including metals such as nickel, cobalt, and chromium, preservatives, and adhesives. When such materials are used internally in biomedical devices, they are similarly capable of causing sensitization and an inflammatory response. Sometimes, the reaction remains internal, and presents as swelling, pain, stiffness, decreased range of motion, and internal itching around the implant. Such reactions may, in some cases, also extend to include a localized or, rarely, systemic contact dermatitis indicative of the same process. This review will present an overview of reported skin and local internal reactions to orthopedic implants, which are the largest category of implanted internal metal devices. Immune reactions to smaller categories of medical appliances include cardiac devices and vascular stents, neuromodulation devices, diabetic appliances, Nuss bar surgery for pectus excavatum, and dental and spinal implants. We will review the available diagnostic tools, the consensus on interpretation, and reported strategies for treatment.
Collapse
Affiliation(s)
- Karin A Pacheco
- Division of Environmental & Occupational Health Sciences, National Jewish Health, Denver, Colo; Environmental & Occupational Health Division, Colorado School of Public Health, Aurora, Colo.
| | - Jacob P Thyssen
- Department of Dermatology and Venereology, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
4
|
Dohm JC, Schmidt S, Puente Reyna AL, Richter B, Santana A, Grupp TM. Comparative Study of Zirconium Nitride Multilayer Coatings: Crystallinity, In Vitro Oxidation Behaviour and Tribological Properties Deposited via Sputtering and Arc Deposition. J Funct Biomater 2024; 15:223. [PMID: 39194662 DOI: 10.3390/jfb15080223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Revised: 08/09/2024] [Accepted: 08/10/2024] [Indexed: 08/29/2024] Open
Abstract
This study aims to evaluate and compare the properties of a biomedical clinically established zirconium nitride (ZrN) multilayer coating prepared using two different techniques: pulsed magnetron sputtering and cathodic arc deposition. The investigation focuses on the crystalline structure, grain size, in-vitro oxidation behaviour and tribological performance of these two coating techniques. Experimental findings demonstrate that the sputter deposition process resulted in a distinct crystalline structure and smaller grain size compared to the arc deposition process. Furthermore, in vitro oxidation caused oxygen to penetrate the surface of the sputtered ZrN top layer to a depth of 700 nm compared to 280 nm in the case of the arc-deposited coating. Finally, tribological testing revealed the improved wear rate of the ZrN multilayer coating applied by sputter deposition.
Collapse
Affiliation(s)
- Julius C Dohm
- Research & Development, Aesculap AG, 78532 Tuttlingen, Germany
- Musculoskeletal University Center Munich (MUM), Department of Orthopaedic and Trauma Surgery, Ludwig Maximilians University Munich, Campus Grosshadern, 81377 Munich, Germany
| | - Susann Schmidt
- Department of Medical Engineering, IHI Ionbond AG, 4657 Dulliken, Switzerland
| | | | - Berna Richter
- Research & Development, Aesculap AG, 78532 Tuttlingen, Germany
| | - Antonio Santana
- Department of Medical Engineering, IHI Ionbond AG, 4657 Dulliken, Switzerland
| | - Thomas M Grupp
- Research & Development, Aesculap AG, 78532 Tuttlingen, Germany
- Musculoskeletal University Center Munich (MUM), Department of Orthopaedic and Trauma Surgery, Ludwig Maximilians University Munich, Campus Grosshadern, 81377 Munich, Germany
| |
Collapse
|
5
|
Xie F, Sheng S, Ram V, Pandit H. Hypoallergenic Knee Implant Usage and Clinical Outcomes: Are They Safe and Effective? Arthroplast Today 2024; 28:101399. [PMID: 39139362 PMCID: PMC11320431 DOI: 10.1016/j.artd.2024.101399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 03/24/2024] [Accepted: 04/03/2024] [Indexed: 08/15/2024] Open
Abstract
Background One of the most debated topics in modern total knee arthroplasty (TKA) is the impact of metal hypersensitivity (MH) as a potential cause of prosthesis failure. Implanting hypoallergenic prostheses to avoid potential problems in suspected cases of MH is one treatment option that can be used in such cases. However, their long-term clinical safety and efficacy are not well proven. Methods All literature relevant to modern hypoallergenic implants were reviewed and summarized to provide a comprehensive synopsis. In addition, a detailed literature search was performed on PUBMED, MEDLINE, and Google Scholar to identify all the clinical studies reporting outcomes for hypoallergenic knee implants. Our search was confined to those studies published as full manuscripts in the English language from July 2018 to July 2023. Results To minimize the risk of MH, new implant variants have been developed which are either under clinical evaluation or in routine clinical use. These include conventional metal implants with protective coatings (mono- or multilayer) and metal-free implants. However, there is insufficient clinical data to confirm the rationale and effectiveness of using these "hypoallergenic" TKA implants. Conclusions Published studies and arthroplasty registry data analyses indicate no significant differences between hypoallergenic and standard TKAs with overall good survival rates. In the future, further high-quality studies are needed to better understand the complexity of this subject.
Collapse
Affiliation(s)
- Feng Xie
- Department of Orthopedics, The Third Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Shuya Sheng
- Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), University of Leeds, Leeds, UK
| | - Venkatesh Ram
- Chapel Allerton Hospital, C/O Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Hemant Pandit
- Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), University of Leeds, Leeds, UK
- Chapel Allerton Hospital, C/O Leeds Teaching Hospitals NHS Trust, Leeds, UK
| |
Collapse
|
6
|
Lin ZH, Chang HC, Wu YL, Gau SY. Increased Risk of New-Onset Rheumatoid Arthritis Among Osteoarthritis Patients Received Total Knee Arthroplasty: a global federated health network analysis. Int J Med Sci 2024; 21:994-1002. [PMID: 38774753 PMCID: PMC11103392 DOI: 10.7150/ijms.93457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 03/28/2024] [Indexed: 05/24/2024] Open
Abstract
Background: Complications of total knee arthroplasty (TKA) had been widely discussed. However, whether TKA influence risk of rheumatoid arthritis (RA) in osteoarthritis patients remained uncertain. We intend to evaluate the risk of RA in osteoarthritis patients underwent TKA. Methods: In this retrospective cohort study, data was retrieved from the US collaborative networks in TriNetX research network. Within the study period between 2005 and 2017, osteoarthritis patients underwent TKA were enrolled as case cohort whereas osteoarthritis patients never underwent TKA were enrolled as control cohort. Covariates were matched via propensity score matching. Risk of RA in TKA patients were valuated under various follow-up time and sensitivity models. Results: Under 1-year, 3-year and 5-year of follow-up, TKA patients were associated with significantly elevated risk of RA, especially under 1-year follow-up (HR=1.74; 95% CI, 1.39-2.18). Subgroup analysis demonstrated a significant increase in the risk of RA following TKA in the female subgroup (HR=1.42; 95% CI, 1.24-1.63), the subgroup aged 18-64 years (HR=1.48; 95% CI, 1.11-1.97), and the subgroup aged greater than 65 years old (HR=1.38; 95% CI, 1.21-1.58) based on 5-year follow-up. Conclusion: Clinicians should be concerned about uncharted association between TKA and RA reported our current study. Additional prospective studies and in-depth mechanistic inquiries were warranted to determine the causation.
Collapse
Affiliation(s)
- Zong-Han Lin
- Department of Medical Education and Research, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
| | - Hui-Chin Chang
- Evidence-based Medicine Center, Chung Shan Medical University Hospital, Taichung, Taiwan
- Library, Chung Shan Medical University Hospital, Taichung, Taiwan
- School of Medicine, Chung Shan Medical University, Taichung, Taiwan
| | - Yu-Lun Wu
- Department of Neurosurgery, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
- School of Medicine, College of Medicine, National Sun Yat-sen University, Kaohsiung, Taiwan
| | - Shuo-Yan Gau
- School of Medicine, Chung Shan Medical University, Taichung, Taiwan
- Department of Medical Education, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
- Orthopedics Department, Chi-Mei Medical Center, Tainan, Taiwan
| |
Collapse
|
7
|
Huang C, Chiang SYV, Gawkrodger DJ. The contribution of metal allergy to the failure of metal alloy implants, with special reference to titanium: Current knowledge and controversies. Contact Dermatitis 2024; 90:201-210. [PMID: 38148670 DOI: 10.1111/cod.14481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 11/26/2023] [Accepted: 11/29/2023] [Indexed: 12/28/2023]
Abstract
After almost three-quarters of a century during which contact dermatologists have often struggled to comprehend the relationship between metal allergy and failure of metal-alloy containing implant, it is possible to say that a relationship does exist, particularly for cobalt and chromium, but also for nickel. There is still debate as to whether allergy develops as a consequent of failure but thenceforth contributes to it, or whether sensitisation starts first and induces failure secondarily-opinion probably favours the first. Metal-on-polypropylene articulations were associated with few metal allergic problems but now are less favoured by orthopaedists due to plastic wear products causing osteolysis and pseudotumour formation through local inflammation. New metal alloys are regularly being introduced such that interested dermatologists need to stay on top of the situation. The jury is still out as to whether the recent favouring of titanium-containing alloys will confirm them to be more inert allergenically. Case reports do show some clinical reactions to titanium-containing implants and patch test series have inferred sometimes quite a high background rate of allergy, but interpretation must be tempered by the awareness that titanium salts on patch testing have a tendency to cause irritant reactions. Blood monitoring of metal ion values is now recommended in certain situations after joint replacement and increasing levels may be an indication that allergy with joint failure can develop, in which case patch testing is indicated, and suggested series are available. Predictive patch testing, whilst generally not recommended in the past, has been introduced into some protocols often by non-dermatologists, such that it is now needed for temporo-mandibular joint and Nuss bar insertion, and it can be anticipated that this may become more commonplace in the future. One of the major current deficits for patch testers is standardised guidance on which preparation or preparations to use for suspected titanium allergy. One suggestion is 0.5% titanium sulphate in petrolatum, though experience in at least one centre suggests the use of a battery of titanium salts might be desirable.
Collapse
Affiliation(s)
- Chenghao Huang
- Calderdale Royal Hospital, Calderdale and Huddersfield NHS Foundation Trust, Halifax, UK
| | - Shu Yu Vanessa Chiang
- Calderdale Royal Hospital, Calderdale and Huddersfield NHS Foundation Trust, Halifax, UK
| | - David J Gawkrodger
- Department of Dermatology, Royal Hallamshire Hospital, University of Sheffield, Sheffield, UK
| |
Collapse
|
8
|
Tille E, Beyer F, Lützner C, Postler A, Thomas P, Summer B, Lützner J. No difference in patient reported outcome and inflammatory response after coated and uncoated total knee arthroplasty - a randomized controlled study. BMC Musculoskelet Disord 2023; 24:968. [PMID: 38098024 PMCID: PMC10720193 DOI: 10.1186/s12891-023-07061-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 11/24/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND Allergies against implant materials are still not fully understood. Despite controversies about its relevance, some patients need treatment with hypoallergenic implants. This study compared coated and standard total knee arthroplasty (TKA) regarding inflammatory response and patient-reported outcome measures (PROMs). METHODS 76 patients without self-reported allergies against implant materials were included in a RCT and received a coated or standard TKA of the same cemented posterior-stabilized knee system. 73 patients completed the 3-year follow-up. Two patients died and there was one revision surgery. Serum levels of cytokines with a possible role in implant allergy were measured in patient`s serum (IL-1beta, IL-5, IL-6, IL-8, IL-10, IFN γ, TNF α) prior to, one and three years after surgery. Furthermore, PROMs including knee function (Oxford Knee Score, Knee Society Score) and health-related quality of life (QoL, EuroQuol questionnaire) were assessed. Additionally, 8 patients with patch-test proven skin allergy against implant materials who received the coated implant were assessed similarly and compared to a matched-pair group receiving the same implant. RESULTS There were no differences in function and QoL between the assessed groups at any follow-up. The majority of patients demonstrated no elevation of the measured blood cytokines. Cytokine patterns showed no differences between study groups at any follow-up. The allergy patients demonstrated slower functional improvement and minor differences in cytokine pattern. Yet these results were not significant. There were no differences in the matched-pair analysis. CONCLUSION We observed no relevant increase in serum cytokine levels in any group. The inflammatory response measured seems limited, even in allergy patients. Furthermore, there were no differences between coated and standard TKA in non-allergy patients in the 3-year Follow-Up period. TRIAL REGISTRATION The study protocol was registered in the US National Institutes of Health's database ( http://www. CLINICALTRIALS gov ) registry under NCT03424174 on 03/17/2016.
Collapse
Affiliation(s)
- Eric Tille
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany.
| | - Franziska Beyer
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany
| | - Cornelia Lützner
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany
| | - Anne Postler
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany
| | - Peter Thomas
- Department of Dermatology und Allergology, Ludwig-Maximilians-University, Munich, Germany
| | - Burkhard Summer
- Department of Dermatology und Allergology, Ludwig-Maximilians-University, Munich, Germany
| | - Jörg Lützner
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherst. 74, 01307, Dresden, Germany
| |
Collapse
|
9
|
Fortmann C, Göen T, Wiesner S, Hegermann J, Kiblawi R, Dohna M, Ure BM, Renz DM, Petersen C, Kuebler JF. Titanium nitride coating of pectus bar increases metal contamination after minimally-invasive repair of pectus excavatum. PLoS One 2023; 18:e0292616. [PMID: 37824548 PMCID: PMC10569521 DOI: 10.1371/journal.pone.0292616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 09/25/2023] [Indexed: 10/14/2023] Open
Abstract
INTRODUCTION Previous studies demonstrated a release of toxic metals, e.g. nickel and chromium, from stainless steel bars used for minimally invasive repair of pectus excavatum (MIRPE). In the present study, we investigated the impact of titanium nitride coating on the metal release and exposure of MIRPE patients. MATERIAL AND METHODS We analyzed the courses of nickel and chromium levels in blood, urine and local tissue in patients undergoing MIRPE with a titanium nitride coated pectus bar between 03/2017 and 10/2018. Sample collection was scheduled prior to MIRPE, at defined postoperative time points and at bar removal. Additionally, we evaluated irritative symptoms. Results were compared to a control group who received uncoated stainless steel bars in a previous time period (03/2015-02/2017). RESULTS 12 patients received coated pectus bars (mean age 15.7 years). The control group included 28 patients. After implantation of a titanium nitride coated bar, significant increase in systemic nickel and chromium levels after one, two and three years was noted. In an interim analysis one year after MIRPE, we observed patients with coated bars to have significantly elevated trace metal values compared to the control group. This elevation persisted throughout the observation period. Tissue metal values were also significantly increased. Irritative symptoms occurred significantly more often in study patients compared to controls (50.0% vs. 14.3%). CONCLUSIONS Coating of pectus bars with titanium nitride failed to reduce metal contamination after MIRPE. Instead, it resulted in a significant increase of trace metal levels after MIRPE, compared to patients with stainless steel bars, which may be explained by wear of the coating and inter-component mobilization processes.
Collapse
Affiliation(s)
- Caroline Fortmann
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Thomas Göen
- Social and Environmental Medicine, Institute and Outpatient Clinic of Occupational, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Soeren Wiesner
- Hannover Medical School, Institute for Biostatistics, Hannover, Germany
| | - Jan Hegermann
- Hannover Medical School, Research Core Unit Electron Microscopy, Institute of Functional and Applied Anatomy, Hannover, Germany
| | - Rim Kiblawi
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Martha Dohna
- Department of Pediatric Radiology, Hannover Medical School, Institute of Diagnostic and Interventional Radiology, Hannover, Germany
| | - Benno M. Ure
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Diane Miriam Renz
- Department of Pediatric Radiology, Hannover Medical School, Institute of Diagnostic and Interventional Radiology, Hannover, Germany
| | - Claus Petersen
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Joachim F. Kuebler
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
10
|
Shimmyo A, Takeda Y, Fukunishi S. Difficult Preoperative Diagnosis of Suspected Metal Hypersensitivity in a Case with Early Failure of Bipolar Hemiarthroplasty. Case Rep Orthop 2023; 2023:8656265. [PMID: 37292174 PMCID: PMC10247313 DOI: 10.1155/2023/8656265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 04/20/2023] [Accepted: 05/15/2023] [Indexed: 06/10/2023] Open
Abstract
Background Metal hypersensitivity is a rare complication after total hip arthroplasty (THA), and no reliable diagnostic method for metal hypersensitivity to orthopedic metal implants has yet been established. Case report. A 57-year-old woman underwent hemiarthroplasty using a metal implant despite a skin allergy to metal jewelry. Two years after surgery, the patient developed early hemiarthroplasty failure and refractory erythema. Although the patient was clinically suspected to have a hypersensitivity to metal, the preoperative screening test was negative, and patient underwent revision surgery with cemented THA. Postoperatively, the erythema as well as her hip pain disappeared completely. Conclusion Patients with clinically suspected metal hypersensitivity should undergo primary and revision total hip arthroplasty using hypoallergenic implants regardless of preoperative screening results.
Collapse
Affiliation(s)
- Airi Shimmyo
- Department of Orthopedic Surgery, Hyogo Medical University, Nishinomiya, Hyogo, Japan
| | - Yu Takeda
- Department of Orthopedic Surgery, Hyogo Medical University, Nishinomiya, Hyogo, Japan
| | | |
Collapse
|
11
|
Echeverri E, Skjöldebrand C, O'Callaghan P, Palmquist A, Kreuger J, Hulsart-Billström G, Persson C. Fe and C additions decrease the dissolution rate of silicon nitride coatings and are compatible with microglial viability in 3D collagen hydrogels. Biomater Sci 2023; 11:3144-3158. [PMID: 36919682 DOI: 10.1039/d2bm02074b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
Abstract
Silicon nitride (SiN) coatings may reduce unwanted release of metal ions from metallic implants. However, as SiN slowly dissolves in aqueous solutions, additives that reduce this dissolution rate would likely increase the lifetime and functionality of implants. Adding iron (Fe) and carbon (C) permits tuning of the SiN coatings' mechanical properties, but their effect on SiN dissolution rates, and their capacity to reduce metal ion release from metallic implant substrates, have yet to be investigated. Such coatings have recently been proposed for use in spinal implants; therefore, it is relevant to assess their impact on the viability of cells expected at the implant site, such as microglia, the resident macrophages of the central nervous system (CNS). To study the effects of Fe and C on the dissolution rate of SiN coatings, compositional gradients of Si, Fe and C in combination with N were generated by physical vapor deposition onto CoCrMo discs. Differences in composition did not affect the surface roughness or the release of Si, Fe or Co ions (the latter from the CoCrMo substrate). Adding Fe and C reduced ion release compared to a SiN reference coating, which was attributed to altered reactivity due to an increase in the fraction of stabilizing Si-C or Fe-C bonds. Extracts from the SiN coatings containing Fe and C were compatible with microglial viability in 2D cultures and 3D collagen hydrogels, to a similar degree as CoCrMo and SiN coated CoCrMo reference extracts. As Fe and C reduced the dissolution rate of SiN-coatings and did not compromise microglial viability, the capacity of these additives to extend the lifetime and functionality of SiN-coated metallic implants warrants further investigation.
Collapse
Affiliation(s)
- Estefanía Echeverri
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| | - Charlotte Skjöldebrand
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| | - Paul O'Callaghan
- Department of Medical Cell Biology, Science for Life Laboratory, Uppsala University, Sweden
| | | | - Johan Kreuger
- Department of Medical Cell Biology, Science for Life Laboratory, Uppsala University, Sweden
| | - Gry Hulsart-Billström
- Translational PET Imaging, Department of Medicinal Chemistry, Uppsala University, Sweden
| | - Cecilia Persson
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Sweden.
| |
Collapse
|
12
|
Lützner J, Beyer F, Lützner C, Tille E, Postler AE. A Novel Multilayer-Coating for Total Knee Arthroplasty Implants is Safe - 10-Year Results From a Randomized-Controlled Trial. J Arthroplasty 2023; 38:90-95.e1. [PMID: 35921997 DOI: 10.1016/j.arth.2022.07.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 07/14/2022] [Accepted: 07/17/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND This randomized-controlled trial was initiated to compare a new multilayer hypoallergenic coating system with the standard implant in total knee arthroplasty (TKA) in terms of serum metal ion levels, patient-reported outcomes (PROs), and implant survival. METHODS A total of 120 patients were randomized to receive a coated or standard TKA of the same knee system. Serum metal ion levels (ie, cobalt, chromium, molybdenum, and nickel) as well as knee function (Oxford Knee Score, OKS), quality of life (SF-36), and physical activity (UCLA activity scale) were assessed before surgery and until the 10 year follow-up. A total of 24 patients died and there was one revision in each group. This resulted in 85 patients who completed follow-up. RESULTS Both groups demonstrated equally good improvement in PROs after surgery and constant score values thereafter. The majority of patients had metal ion serum levels below detection limit. Only cobalt levels demonstrated a slight increase in the standard group at 5- and 10-year follow-up. However, all patients displayed values below 3 μg/L. The cumulative 10-year survival was 98% in both groups. CONCLUSION There were no problems with the new coating system. No relevant increase in metal ion serum levels were measured. A slight increase in cobalt serum levels in the standard TKA was noted, thus not reaching critical values. The new coating system demonstrated equally good PROs as the standard TKA. Excellent implant survival was observed in both groups. LEVEL OF EVIDENCE I.
Collapse
Affiliation(s)
- Jörg Lützner
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital, TU Dresden, Dresden, Germany
| | - Franziska Beyer
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital, TU Dresden, Dresden, Germany
| | - Cornelia Lützner
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital, TU Dresden, Dresden, Germany
| | - Eric Tille
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital, TU Dresden, Dresden, Germany
| | - Anne Elisabeth Postler
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital, TU Dresden, Dresden, Germany
| |
Collapse
|
13
|
Podzimek S, Himmlova L, Janatova T, Bjørklund G, Vrbova R, Janovska M, Peana M, Chasapis CT, Vinsu A, Prochazkova J, Duskova J. Metal hypersensitivity and pro-inflammatory cytokine production in patients with failed orthopedic implants: A case-control study. Clin Immunol 2022; 245:109152. [DOI: 10.1016/j.clim.2022.109152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 09/30/2022] [Accepted: 10/03/2022] [Indexed: 11/29/2022]
|
14
|
Peacock CJH, Fu H, Asopa V, Clement ND, Kader D, Sochart DH. The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review. ARTHROPLASTY 2022; 4:40. [PMID: 36050799 PMCID: PMC9438335 DOI: 10.1186/s42836-022-00144-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 08/08/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
To assess the Nickel sensitizing potential of total knee arthroplasty (TKA), explore the relationship between hypersensitivity and clinical outcomes, and evaluate the utility of skin patch testing pre- and/or postoperatively.
Materials and methods
A literature search was performed through EMBASE, Medline and PubMed databases. Articles were screened independently by two investigators. The level of evidence of studies was assessed using the Oxford Centre for Evidence-Based Medicine Criteria and the quality evaluated using the Methodological Index for Non-randomized Studies and Cochrane risk-of-bias tools.
Results
Twenty studies met the eligibility criteria, reporting on 1354 knee arthroplasties. Studies included patients undergoing primary or revision TKA, pre- and/or postoperatively, and used patch testing to identify Nickel hypersensitivity. Prevalence of Nickel hypersensitivity ranged from 0% to 87.5%. One study compared the prevalence of Nickel hypersensitivity in the same patient group before and after surgery and noted newly positive patch test reactions in three patients (4.2%). Three studies reported lower prevalence of Nickel hypersensitivity in postoperative patients compared to preoperative ones. Seven studies suggested that hypersensitivity might cause adverse clinical outcomes, but six did not support any relationship. Seven studies recommended preoperative patch testing in patients with history of metal allergy, and nine concluded that testing may be valuable postoperatively.
Conclusions
Patients undergoing TKA with no prior history of metal hypersensitivity do not seem to be at an increased risk of developing Nickel hypersensitivity, and there is conflicting evidence that patients with pre-existing hypersensitivity are more likely to experience adverse outcomes. Patch testing remains the most commonly used method for diagnosing hypersensitivity, and evidence suggests preoperative testing in patients with history of metal allergy to aid prosthesis selection, and postoperatively in patients with suspected hypersensitivity once common causes of implant failure have been excluded, since revision with hypoallergenic implants may alleviate symptoms.
Collapse
|
15
|
Lawrie CM, Bartosiak KA, Barrack TN, Nunley RM, Wright RW, Barrack RL. James A. Rand Young Investigator's Award: Questioning the "Nickel Free" Total Knee Arthroplasty. J Arthroplasty 2022; 37:S705-S709. [PMID: 35378232 DOI: 10.1016/j.arth.2022.03.058] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 03/14/2022] [Accepted: 03/15/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND A study was performed to measure metal ions present in the knee joint after performing a total knee arthroplasty (TKA) with standard cobalt chromium (CoCr) components as well as with "nickel-free" oxidized zirconium femoral and titanium tibial (OxZr/Ti) components. METHODS Knee joint fluid was collected prior to arthrotomy, and on postoperative day one to determine the amount of metal debris generated when performing a TKA with standard instrumentation from consecutive cases with CoCr components (n = 24) and OxZr/Ti components (n = 16). RESULTS CoCr implant patients had statistically higher levels of nickel (Ni) (29.7%, P = .033), cobalt (Co), (1,100.7%, P < .0001) and chromium (Cr) (118.9%, P < .0001) postoperatively. The cutting blocks and sawblades do not contain Co, which therefore must have come from the components. The metal ions generated from the sawblades and cutting blocks, therefore, could be discerned from the OxZr/Ti whose components don't contain Co, Cr, or Ni. The OxZr patients had significantly higher Cr (9.5×, P < .001) and Ni (5.1×, P < .001) post-TKA vs pre-TKA; Co levels were not significantly different as expected with the absence of Co in the components (P = .60). The Ni levels generated in performing an Oxinium TKA was 3.3 times higher than when performing a CoCr TKA (1.37 vs. 41 ppb, P < .001). CONCLUSIONS The substantial degree of Ni generation resulting from performing a hypoallergenic "nickel-free" TKA calls into questions the rationale of utilizing more expensive lower Ni components on the basis of known or suspected Ni or Cr allergy.
Collapse
Affiliation(s)
- Charles M Lawrie
- Miami Orthopedics and Sports Medicine Institute, Baptist Health South Florida, Miami, Florida
| | - Kimberly A Bartosiak
- Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, Missouri
| | - Toby N Barrack
- Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, Missouri
| | - Ryan M Nunley
- Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, Missouri
| | - Rick W Wright
- Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Robert L Barrack
- Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, Missouri
| |
Collapse
|
16
|
Battaglia AG, Ali-Zade C, Monti L, Al Khawashki H, Winkler H, Del Sel H, Mavrogenis AF, Benzakour T, Drago L, Romanò CL. Metal Hypersensitivity or Missed Periprosthetic Joint Infection? A Critical Review. Orthopedics 2022; 45:e73-e78. [PMID: 34978510 DOI: 10.3928/01477447-20211227-04] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The World Association Against Infection in Orthopedics And Trauma (W.A.I.O.T.) Study Group on Bone And Joint Infection Definitions Metal hypersensitivity (MHS) has been investigated by several authors as a possible reason for painful total joint arthroplasty, with controversial results. Periprosthetic joint infection (PJI) is another possible source of unexplained pain and implant failure that may be difficult to diagnose if not properly investigated. We performed this critical review to assess whether the current literature on MHS includes an adequate diagnostic workup to discern metal allergy from PJI. The results of this review highlight the importance of assessing patients for PJI before making a diagnosis of MHS and emphasize that the methods currently used to exclude PJI are substantially inadequate. Therefore, well-designed clinical trials with adequate diagnostic protocols and definitions of PJI that can differentiate MHS from low-grade PJI are needed. [Orthopedics. 2022;45(2):e73-e78.].
Collapse
|
17
|
Deshpande R, Shukla S, Kale A, Deshmukh N, Nisal A, Venugopalan P. Silk Fibroin Microparticle Scaffold for Use in Bone Void Filling: Safety and Efficacy Studies. ACS Biomater Sci Eng 2022; 8:1226-1238. [PMID: 35166518 DOI: 10.1021/acsbiomaterials.1c01103] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Silk fibroin (SF) is a natural biocompatible protein polymer extracted from cocoons of silkworm Bombyx mori. SF can be processed into a variety of different forms and shapes that can be used as scaffolds to support bone regeneration. Three-dimensional (3D) SF scaffolds have shown promise in bone-void-filling applications. In in vitro studies, it has been demonstrated that a microparticle-based SF (M-RSF) scaffold promotes the differentiation of stem cells into an osteoblastic lineage. The expression of differentiation markers was also significantly higher for M-RSF scaffolds as compared to other SF scaffolds and commercial ceramic scaffolds. In this work, we have evaluated the in vitro and in vivo biocompatibility of M-RSF scaffolds as per the ISO 10993 guidelines in a Good Laboratory Practice (GLP)-certified facility. The cytotoxicity, immunogenicity, genotoxicity, systemic toxicity, and implantation studies confirmed that the M-RSF scaffold is biocompatible. Further, the performance of the M-RSF scaffold to support bone formation was evaluated in in vivo bone implantation studies in a rabbit model. Calcium sulfate (CaSO4) scaffolds were chosen as reference material for this study as they are one of the preferred materials for bone-void-filling applications. M-RSF scaffold implantation sites showed a higher number of osteoblast and osteoclast cells as compared to CaSO4 implantation sites indicating active bone remodeling. The number density of osteocytes was double for M-RSF scaffold implantation sites, and these M-RSF scaffold implantation sites were characterized by enhanced collagen deposition, pointing toward a finer quality of the new bone formed. Moreover, the M-RSF scaffold implantation sites had a negligible incidence of secondary fractures as compared to the CaSO4 implantation sites (∼50% sites with secondary fracture), implying a reduction in postsurgical complications. Thus, the study demonstrates that the M-RSF scaffold is nontoxic for bone-void-filling applications and facilitates superior healing of fracture defects as compared to commercial calcium-based bone void fillers.
Collapse
Affiliation(s)
- Rucha Deshpande
- Serigen Mediproducts Pvt Ltd., Plot no. 9, Electronic Co-op Estate, Satara Road, Parvati Paytha, Pune 411009, India
| | - Swati Shukla
- Serigen Mediproducts Pvt Ltd., Plot no. 9, Electronic Co-op Estate, Satara Road, Parvati Paytha, Pune 411009, India
| | - Amod Kale
- Intox Private Limited, Pune, 375, Urawade, Tal. Mulshi, Pune 412115, India
| | - Narendra Deshmukh
- Intox Private Limited, Pune, 375, Urawade, Tal. Mulshi, Pune 412115, India
| | - Anuya Nisal
- Polymer Science and Engineering Dept., CSIR-National Chemical Laboratory, Homi Bhabha Road, Pashan, Pune 411008, India
| | - Premnath Venugopalan
- Polymer Science and Engineering Dept., CSIR-National Chemical Laboratory, Homi Bhabha Road, Pashan, Pune 411008, India
| |
Collapse
|
18
|
Lazarenko HO, Boiko IV. THE METHOD OF ATOMIC FORCE MICROSCOPY AS A POSSIBLE TOOL FOR TESTING THE BIOCOMPATIBILITY OF IMPLANTS IN TRAUMATOLOGY AND ORTHOPEDICS PRACTICE. WIADOMOSCI LEKARSKIE (WARSAW, POLAND : 1960) 2022; 75:2614-2618. [PMID: 36591742 DOI: 10.36740/wlek202211111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
OBJECTIVE The aim: To establish the possibility of using the atomic force microscope (AFM) to predict the body's reaction to the implant. PATIENTS AND METHODS Materials and methods: A total of 32 patients, 22 men and 10 women, the average age of the patients was 55±6 years, were included in the study. They performed pre- and post-operative testing of the biocompatibility of orthopedic implant materials with the patient's body with the help of AFM. RESULTS Results: According to the research, an increase in pro-inflammatory factors was found, which may indicate a constant inflammatory process, which is probably related to the presence of the implant. CONCLUSION Conclusions: On the basis of atomic force spectroscopy, an express method of testing biomaterials for compatibility with the body of a specific recipient and studying the effect of the reactions of recipient tissues on the surface of various implants has been developed. The obtained results can be useful in planning further clinical studies.
Collapse
Affiliation(s)
- Hlib O Lazarenko
- STATE INSTITUTION OF SCIENCE «RESEARCH AND PRACTICAL CENTER OF PREVENTIVE AND CLINICAL MEDICINE», KYIV, UKRAINE, STATE ADMINISTRATIVE DEPARTMENT, KYIV, UKRAINE
| | - Igor V Boiko
- STATE INSTITUTION OF SCIENCE «RESEARCH AND PRACTICAL CENTER OF PREVENTIVE AND CLINICAL MEDICINE», KYIV, UKRAINE, STATE ADMINISTRATIVE DEPARTMENT, KYIV, UKRAINE
| |
Collapse
|
19
|
Flejszar M, Chmielarz P, Gießl M, Wolski K, Smenda J, Zapotoczny S, Cölfen H. A new opportunity for the preparation of PEEK-based bone implant materials: From SARA ATRP to photo-ATRP. POLYMER 2022. [DOI: 10.1016/j.polymer.2022.124587] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
20
|
Mihara M, Hirakawa K, Takayanagi S, Maekawa K, Kitagawa R, Sato T. Adverse Local Tissue Reaction and Late-Onset Eosinophilic Gastroenteritis After Primary Total Hip Arthroplasty: A Case Report. JBJS Case Connect 2021; 11:01709767-202112000-00060. [PMID: 34807887 DOI: 10.2106/jbjs.cc.21.00333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
CASE A 67-year-old woman suffered from chronic diarrhea at 10 years after right total hip arthroplasty. She also had a pseudotumor caused by an adverse local tissue reaction (ALTR) in her right pelvis. We performed revision arthroplasty, in part because we suspected the diarrhea may have been associated with the intrapelvic pseudotumor. She was later diagnosed with eosinophilic gastroenteritis (EGE). CONCLUSION Although these two diseases were thought be be related through a similar immune reaction, our patient's clinical course suggests that the ALTR and EGE were independent events.
Collapse
Affiliation(s)
- Masahiko Mihara
- Shonan Kamakura Joint Reconstruction Center, Kamakura, Japan
| | - Kazuo Hirakawa
- Shonan Kamakura Joint Reconstruction Center, Kamakura, Japan
| | | | - Kazunari Maekawa
- Division of Pathophysiology, Department of Pathology, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan
| | - Ryuta Kitagawa
- Department of Gastroenterology, Juntendo University Nerima Hospital, Nerima City, Japan
| | - Toshifumi Sato
- Department of Gastroenterology, Juntendo University Nerima Hospital, Nerima City, Japan
| |
Collapse
|
21
|
D’Ambrosi R, Loucas R, Loucas M, Giorgino R, Ursino N, Peretti GM. No Clinical or Radiographic Differences Between Cemented Cobalt-Chromium and Titanium-Niobium Nitride Mobile-Bearing Unicompartmental Knee Arthroplasty. Indian J Orthop 2021; 55:1195-1201. [PMID: 34824720 PMCID: PMC8586226 DOI: 10.1007/s43465-021-00486-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 08/10/2021] [Indexed: 02/04/2023]
Abstract
PURPOSE This study aimed to compare the clinical and radiographic outcomes of patients with positive patch tests undergoing a medial mobile-bearing titanium-niobium nitride (TiNbN) unicompartmental knee arthroplasty (UKA) to patients undergoing standard UKA (cobalt-chromium [CoCr] implants). METHODS Two successive groups of patients, amounting to a total of 246 individuals, who received Oxford (Zimmer-Biomet, Warsaw, Indiana, USA) UKA were included. The first group was composed of a series of 203 consecutive standard CoCr UKAs (Standard Group), while the second group comprised 43 consecutive hypoallergenic TiNbN UKAs (HA group). The patients of the second group had a positive epicutaneous patch test result for metals. Each patient was evaluated using the Oxford Knee Score (OKS) and Knee Society Score (KSS) a day prior to the surgery (T 0) and at two consecutive follow-ups, namely T 1 (minimum follow-up of 12 months) and T 2 (minimum follow-up of 34 months). Radiographic measurements were performed at the final follow-up (T 2). RESULTS No statistical differences were noted between the two groups regarding demographic data (p > 0.05). No clinical or radiographic differences were found between the HA and standard groups at any follow-up (p > 0.05). A statistically significant improvement was found at any follow-up for both OKS and KSS (p < 0.05). CONCLUSIONS No clinical or radiographic differences between the hypoallergenic and standard cobalt-chromium groups at any follow-up were found, with a clinically significant improvement being experienced by both groups during the entire follow-up. LEVEL OF EVIDENCE Level II-comparative prospective study. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s43465-021-00486-3.
Collapse
Affiliation(s)
| | - Rafael Loucas
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland
| | - Marios Loucas
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland
| | - Riccardo Giorgino
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Mangiagalli 31, 20133 Milan, Italy
| | - Nicola Ursino
- IRCCS Istituto Ortopedico Galeazzi, Via Galeazzi 4, 20161 Milan, Italy
| | - Giuseppe Maria Peretti
- IRCCS Istituto Ortopedico Galeazzi, Via Galeazzi 4, 20161 Milan, Italy
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Mangiagalli 31, 20133 Milan, Italy
| |
Collapse
|
22
|
Matar HE, Porter PJ, Porter ML. Metal allergy in primary and revision total knee arthroplasty : a scoping review and evidence-based practical approach. Bone Jt Open 2021; 2:785-795. [PMID: 34587776 PMCID: PMC8558451 DOI: 10.1302/2633-1462.210.bjo-2021-0098.r1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
AIMS Metal allergy in knee arthroplasty patients is a controversial topic. We aimed to conduct a scoping review to clarify the management of metal allergy in primary and revision total knee arthroplasty (TKA). METHODS Studies were identified by searching electronic databases: Cochrane Central Register of Controlled Trials, Ovid MEDLINE, and Embase, from their inception to November 2020, for studies evaluating TKA patients with metal hypersensitivity/allergy. All studies reporting on diagnosing or managing metal hypersensitivity in TKA were included. Data were extracted and summarized based on study design, study population, interventions and outcomes. A practical guide is then formulated based on the available evidence. RESULTS We included 38 heterogeneous studies (two randomized controlled trials, six comparative studies, 19 case series, and 11 case reports). The evidence indicates that metal hypersensitivity is a rare complication with some histopathological features leading to pain and dissatisfaction with no reliable screening tests preoperatively. Hypoallergenic implants are viable alternatives for patients with self-reported/confirmed metal hypersensitivity if declared preoperatively; however, concerns remain over their long-term outcomes with ceramic implants outperforming titanium nitride-coated implants and informed consent is paramount. For patients presenting with painful TKA, metal hypersensitivity is a diagnosis of exclusion where patch skin testing, lymphocyte transformation test, and synovial biopsies are useful adjuncts before revision surgery is undertaken to hypoallergenic implants with shared decision-making and informed consent. CONCLUSION Using the limited available evidence in the literature, we provide a practical approach to metal hypersensitivity in TKA patients. Future national/registry-based studies are needed to identify the scale of metal hypersensitivity, agreed diagnostic criteria, and management strategies. Cite this article: Bone Jt Open 2021;2(10):785-795.
Collapse
Affiliation(s)
- Hosam E. Matar
- Wrightington Hospital, Wigan, UK
- Nottingham Elective Orthopaedic Services, Nottingham University Hospital NHS Trust, Nottingham, UK
| | | | | |
Collapse
|
23
|
Gergovska M, Darlenski R, Kazandjieva J. Nickel Allergy of the Skin and Beyond. Endocr Metab Immune Disord Drug Targets 2021; 20:1003-1009. [PMID: 32108006 DOI: 10.2174/1871530320666200228124453] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Revised: 01/25/2020] [Accepted: 03/08/2020] [Indexed: 01/19/2023]
Abstract
BACKGROUND Hypersensitization to nickel is one of the most common contact allergies in the modern world and it is considered to be a major cause of contact dermatitis, especially for hand eczema. OBJECTIVE The aim of this paper is to describe many faces of the nickel allergy and to find out different diagnostic, potential strategies for treatment and prevention in hypersensitized patients. A personal clinical experience with practical clinical cases of contact dermatitis to nickel has also been presented. METHODS Electronic databases on this topic was carried out using PubMed-Medline. RESULTS The literature review identified many articles reporting for nickel contact allergy and pointing the metal as number one allergen in the frequency of positive skin patch test reactions in a large population worldwide. Herein, a summary of the current understanding and evidence on nickel allergy with practical approach and proposed recommendations to the dermatologist, general practitioner, and the allergist were prepared. CONCLUSION The prevalence of nickel allergy represents an important socio-economical and health issue. Metal is one of the most common sensitizing agents worldwide. The morbidity due to this metal represents the allergic contact dermatitis and it is constantly growing in many countries. There are also cases of systemic allergic contact dermatitis, where they could be easily misdiagnosed as adverse drug reactions, which lead to delay of the correct diagnosis and inappropriate treatment.
Collapse
Affiliation(s)
- Malena Gergovska
- Department of Dermatology, Venereology and Allergology, Faculty of Medicine, Pleven, Bulgaria
| | - Razvigor Darlenski
- Department of Dermatology and Venereology, Acibadem City Clinic Tokuda Hospital, Sofia, Bulgaria
| | - Jana Kazandjieva
- Department of Dermatology and Venereology, Faculty of Medicine, Sofia, Bulgaria
| |
Collapse
|
24
|
Titanium and Other Metal Hypersensitivity Diagnosed by MELISA® Test: Follow-Up Study. BIOMED RESEARCH INTERNATIONAL 2021; 2021:5512091. [PMID: 34124241 PMCID: PMC8192180 DOI: 10.1155/2021/5512091] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 05/07/2021] [Accepted: 05/20/2021] [Indexed: 11/22/2022]
Abstract
This study is aimed at proving the clinical benefit of the MELISA® test in the minimization or complete elimination of health problems in patients with confirmed hypersensitivity to metals used for tissue replacements. A group of 305 patients aged 20-75 years with previously proven metal hypersensitivity (initial MELISA® test), mainly to titanium and then to another fifteen metals, was chosen from the database at the Institute of Dental Medicine. From these patients, a final group of 42 patients agreed to participate in the study, 35 of which were female and 7 were male. The patients completed a special questionnaire aimed at information regarding change of health status from their last visit and determining whether the results of the initial MELISA® test and recommendations based on it were beneficial for patients or not. They were clinically examined, and peripheral blood samples were taken to perform follow-up MELISA® tests. Questionnaire data was processed, and the follow-up MELISA® test results were compared with the results of the initial MELISA® tests. For statistical analysis, the Fisher's exact test and paired T-test were used. Thirty-two patients reported that they followed the recommendations based on the results of the initial MELISA® tests, and of these, 30 patients (94%) confirmed significant health improvement. Six patients did not follow the recommendation, and from these, only one patient reported an improvement in his health problems. By comparison of the initial and follow-up MELISA® test results, it can be stated that the hypersensitivity to the given metal decreased or disappeared after the therapeutic interventions performed based on the initial MELISA® test results. The evaluation of the data obtained from patients in this study confirmed a significant clinical benefit of MELISA® test.
Collapse
|
25
|
Chung L, Maestas DR, Lebid A, Mageau A, Rosson GD, Wu X, Wolf MT, Tam AJ, Vanderzee I, Wang X, Andorko JI, Zhang H, Narain R, Sadtler K, Fan H, Čiháková D, Le Saux CJ, Housseau F, Pardoll DM, Elisseeff JH. Interleukin 17 and senescent cells regulate the foreign body response to synthetic material implants in mice and humans. Sci Transl Med 2021; 12:12/539/eaax3799. [PMID: 32295900 DOI: 10.1126/scitranslmed.aax3799] [Citation(s) in RCA: 102] [Impact Index Per Article: 25.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Accepted: 11/12/2019] [Indexed: 12/11/2022]
Abstract
Medical devices and implants made of synthetic materials can induce an immune-mediated process when implanted in the body called the foreign body response, which results in formation of a fibrous capsule around the implant. To explore the immune and stromal connections underpinning the foreign body response, we analyzed fibrotic capsules surrounding surgically excised human breast implants from 12 individuals. We found increased numbers of interleukin 17 (IL17)-producing γδ+ T cells and CD4+ T helper 17 (TH17) cells as well as senescent stromal cells in the fibrotic capsules. Further analysis in a murine model demonstrated an early innate IL17 response to implanted synthetic material (polycaprolactone) particles that was mediated by innate lymphoid cells and γδ+ T cells. This was followed by a chronic adaptive CD4+ TH17 cell response that was antigen dependent. Synthetic materials with varying chemical and physical properties implanted either in injured muscle or subcutaneously induced similar IL17 responses in mice. Mice deficient in IL17 signaling established that IL17 was required for the fibrotic response to implanted synthetic materials and the development of p16INK4a senescent cells. IL6 produced by senescent cells was sufficient for the induction of IL17 expression in T cells. Treatment with a senolytic agent (navitoclax) that killed senescent cells reduced IL17 expression and fibrosis in the mouse implant model. Discovery of a feed-forward loop between the TH17 immune response and the senescence response to implanted synthetic materials introduces new targets for therapeutic intervention in the foreign body response.
Collapse
Affiliation(s)
- Liam Chung
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA.,Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - David R Maestas
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Andriana Lebid
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Ashlie Mageau
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Gedge D Rosson
- Division of Plastic Surgery, Department of Surgery, Johns Hopkins University, Baltimore, MD, USA
| | - Xinqun Wu
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Matthew T Wolf
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA.,Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Ada J Tam
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Isabel Vanderzee
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Xiaokun Wang
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - James I Andorko
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA.,Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Hong Zhang
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Radhika Narain
- Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| | - Kaitlyn Sadtler
- Section on Immuno-Engineering, National Institute for Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD, USA
| | - Hongni Fan
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Daniela Čiháková
- Department of Pathology, Johns Hopkins University, Baltimore, MD, USA
| | | | - Franck Housseau
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Drew M Pardoll
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA
| | - Jennifer H Elisseeff
- Bloomberg~Kimmel Institute for Cancer Immunotherapy and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD 21231, USA. .,Translational Tissue Engineering Center, Wilmer Eye Institute and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21287, USA
| |
Collapse
|
26
|
Mayer AS, Erb S, Kim RH, Dennis DA, Shirname-More L, Pratte KA, Barker EA, Maier LA, Pacheco KA. Sensitization to Implant Components Is Associated with Joint Replacement Failure: Identification and Revision to Nonallergenic Hardware Improves Outcomes. THE JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE 2021; 9:3109-3117.e1. [PMID: 33744472 DOI: 10.1016/j.jaip.2020.12.068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 12/11/2020] [Accepted: 12/29/2020] [Indexed: 10/21/2022]
Abstract
BACKGROUND Over 90% of one million annual US joint replacements are highly successful. Nonetheless, 10% do poorly owing to infection or mechanical issues. Many implant components are sensitizers, and sensitization could also contribute to implant failure. OBJECTIVE To determine the prevalence of implant sensitization in joint failure patients, their clinical characteristics, and implant revision outcomes. We hypothesized that sensitized patients would improve when revised with nonallergenic materials. METHODS We prospectively enrolled 105 joint failure patients referred by orthopedic surgeons who had already excluded infection or mechanical causes. Patients provided informed consent, completed a history and physical examination, patch testing to metals and bone cement, and a nickel lymphocyte proliferation test. A study coordinator was able to contact 64% of patients (n = 67) 9 to 12 months later to evaluate outcomes. RESULTS A total of 59% were sensitized to an implant component: 32% to metal and 37% to bone cement. The nickel lymphocyte proliferation test was 60% sensitive and 96% specific in diagnosing nickel sensitization. Most sensitized subjects reported no or uncertain histories of reactions to a specific material. Implant sensitized patients were younger and reported previous eczema, joint itching, and implant loosening. By 9 to 12 months later, most patients with a revised implant (revised) described significant improvement (16 of 22 revised for sensitization [P = .0003] vs 9 of 13 revised without sensitization [P = .047]) compared with patients without implant revision). All revised patients with sensitization used components to which they were not sensitized. Pain (P = .001), swelling (P = .035), and instability (P = .006) were significantly reduced in the revised sensitized group. CONCLUSIONS Sensitization to implant components is an important cause of unexplained joint replacement failure. Joint revisions based on sensitization information resulted in significant improvements.
Collapse
Affiliation(s)
- Annyce S Mayer
- Division of Environmental and Occupational Health Sciences, Department of Medicine, National Jewish Health, Denver, Colo; Division of Environmental and Occupational Health, University of Colorado School of Medicine, School of Public Health, Aurora, Colo
| | - Samantha Erb
- Graduate Medical Education, Northside Hospital, St Petersburg, Fla
| | | | - Douglas A Dennis
- Department of Bioengineering, Daniel Felix Ritchie School of Engineering and Computer Science, University of Denver, Denver, Colo; Department of Orthopedics, CU Anschutz School of Medicine, Aurora, Colo
| | - Lata Shirname-More
- Division of Environmental and Occupational Health Sciences, Department of Medicine, National Jewish Health, Denver, Colo
| | | | - Elizabeth A Barker
- Division of Environmental and Occupational Health Sciences, Department of Medicine, National Jewish Health, Denver, Colo
| | - Lisa A Maier
- Division of Environmental and Occupational Health Sciences, Department of Medicine, National Jewish Health, Denver, Colo; Division of Environmental and Occupational Health, University of Colorado School of Medicine, School of Public Health, Aurora, Colo; Division of Pulmonary Sciences and Critical Care Medicine, Department of Medicine, School of Medicine, University of Colorado Denver, Aurora, Colo
| | - Karin A Pacheco
- Division of Environmental and Occupational Health Sciences, Department of Medicine, National Jewish Health, Denver, Colo; Division of Environmental and Occupational Health, University of Colorado School of Medicine, School of Public Health, Aurora, Colo.
| |
Collapse
|
27
|
Metal Hypersensitivity in Joint Arthroplasty. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS 2021; 5:01979360-202103000-00007. [PMID: 33720103 PMCID: PMC7963506 DOI: 10.5435/jaaosglobal-d-20-00200] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Accepted: 01/31/2021] [Indexed: 11/18/2022]
Abstract
Metal hypersensitivity in joint arthroplasty is a very controversial topic with limited evidence. With increasing numbers of joint replacements being done annually, a clear understanding of the pathogenesis, clinical picture, preimplant screening, postimplant workup, and treatment plan is crucial. This review article looked at all the available evidence regarding metal hypersensitivity and summarized the key findings. An algorithm was also proposed for preimplant screening, postimplant workup, and management.
Collapse
|
28
|
Röhner E, Heinecke M, Matziolis G. Diagnostic algorithm in aseptic TKA failure - What is evidence-based? J Orthop 2021; 24:248-253. [PMID: 33854292 PMCID: PMC8039505 DOI: 10.1016/j.jor.2021.03.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- E. Röhner
- Corresponding author. Orthopaedic Department, Jena University Hospital, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
| | | | - G. Matziolis
- Orthopaedic Department of the Waldkliniken Eisenberg, University Hospital Jena, 07607, Eisenberg, Germany
| |
Collapse
|
29
|
Gaston TE, Kwan S, Skibicki HE, Cheesman QT, Daniel JN. Morbidity After Metal Allergy to a Total Ankle Implant. Foot Ankle Spec 2020; 13:502-507. [PMID: 32840132 DOI: 10.1177/1938640020950119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Metal allergy to total ankle arthroplasty is rare but can be both an unpredictable and devastating complication. Current literature describing metal allergy in orthopaedics is limited with there being no report to date on metal allergy after total ankle arthroplasty. Our patient underwent a total ankle arthroplasty and developed a diffuse rash 7 weeks postoperatively. The patient then tested positive for a metal allergy and ultimately was converted to an arthrodesis. In the setting of postoperative pain, swelling, erythema, or rash, it is important that metal allergy be on the differential diagnosis. Interestingly, when the patient here underwent allergy testing, only the articulating sides of the implant caused a positive reaction. Thus, allergy testing of both the articular and nonarticular sides of the component is of the utmost importance, as evidenced by the discrepancy found in this case.Levels of Evidence: Level IV: Case report.
Collapse
Affiliation(s)
- Tara E Gaston
- Rowan University School of Osteopathic Medicine, Stratford, New Jersey (TEG, SK, HES).,Rothman Orthopaedic Institute, Philadelphia, Pennsylvania (QTC, JND)
| | - Stephanie Kwan
- Rowan University School of Osteopathic Medicine, Stratford, New Jersey (TEG, SK, HES).,Rothman Orthopaedic Institute, Philadelphia, Pennsylvania (QTC, JND)
| | - Hope E Skibicki
- Rowan University School of Osteopathic Medicine, Stratford, New Jersey (TEG, SK, HES).,Rothman Orthopaedic Institute, Philadelphia, Pennsylvania (QTC, JND)
| | - Quincy T Cheesman
- Rowan University School of Osteopathic Medicine, Stratford, New Jersey (TEG, SK, HES).,Rothman Orthopaedic Institute, Philadelphia, Pennsylvania (QTC, JND)
| | - Joseph N Daniel
- Rowan University School of Osteopathic Medicine, Stratford, New Jersey (TEG, SK, HES).,Rothman Orthopaedic Institute, Philadelphia, Pennsylvania (QTC, JND)
| |
Collapse
|
30
|
Charousset C, Lefebvre Y, Bonnevialle N, Joudet T, Audebert S, Berhouet J, Michelet A, Geais L, Godenèche A. Prevalence of metal hypersensitivity in patients with shoulder pathologies. J Shoulder Elbow Surg 2020; 29:1789-1795. [PMID: 32371039 DOI: 10.1016/j.jse.2020.01.100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 01/22/2020] [Accepted: 01/28/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND To date, medical history and dedicated questionnaires are the fastest and easiest way to assess risks of joint metal hypersensitivity. No published studies determined the overall prevalence of hypersensitivity to metals in patients with shoulder pathologies. The purpose of this study was therefore to estimate the prevalence of metal hypersensitivity reported by patients with shoulder pathologies, and to identify patients at risk of joint metal hypersensitivity based on a dedicated questionnaire. METHODS The authors prospectively asked all adult patients consulting for shoulder pathologies between September 2018 and February 2019 at 10 centers to fill in a form. The main outcome was "reported hypersensitivity to metals," comprising belt buckles, coins, earrings, fancy jewelry, keys, leather, metallic buttons, piercings, spectacles, watch bracelets, or zips. RESULTS A total of 3217 patients agreed to fill in the survey, aged 55 ± 16 (range, 18-101) with equal proportions of men (51%) and women (49%), and a majority of patients consulting for cuff pathology (55%). A total of 891 (28%) patients had professions considered at risk for metal hypersensitivity. The most frequently reported metal hypersensitivities were fancy jewelry (15%), earrings (13%), and watch bracelets (9%). A total of 629 (20%) patients, of which the vast majority were women, reported hypersensitivity to 1 or more metals. CONCLUSIONS This survey of 3217 patients identified 20% who reported metal hypersensitivities, though only 2.2% had done patch tests. Matching profiles of those with positive patch tests to those with no patch tests revealed that 9.4% of the total cohort had similar sex and self-reported metal hypersensitivities. Factors associated with a positive patch test were female sex, self-reported cutaneous allergy, and self-reported metal hypersensitivity. The clinical applicability of these estimates remains uncertain as there is insufficient evidence that allergy to metal implants can be predicted by questionnaires or patch tests.
Collapse
Affiliation(s)
| | - Yves Lefebvre
- Institut de l'Epaule de Strasbourg 16, allée de la Robertsau, Strasbourg, France
| | - Nicolas Bonnevialle
- Département de chirurgie orthopédique, Hôpital Pierre-Paul Riquet, Toulouse, France
| | - Thierry Joudet
- Department of Orthopaedic Surgery, Clinique chirurgicale du Libournais, Libourne, France
| | - Stephane Audebert
- Department of Orthopaedic Surgery, Clinique du Cambresis, Cambrai, France
| | - Julien Berhouet
- Service d'Orthopédie 1C, Centre Hospitalier Universitaire de Tours, Tours, France
| | -
- Shoulder Friends Institute, Paris, France
| | | | | | - Arnaud Godenèche
- Ramsay Générale de Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| |
Collapse
|
31
|
Shanmugham HA, Handa S, De D, Dhillon MS, Aggarwal S. An observational study to determine the sensitizing potential of orthopedic implants. Indian J Dermatol Venereol Leprol 2020; 87:826-830. [PMID: 32134002 DOI: 10.4103/ijdvl.ijdvl_789_18] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2018] [Accepted: 07/01/2019] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Patients who receive orthopedic implants have been shown to develop sensitivity to its components and there are concerns that this sensitivity might lead to contact dermatitis or implant-related problems like loosening and/or failure. The objective of the study was to determine the sensitizing potential of orthopedic implants. METHODS Fifty-four patients undergoing knee, hip, or shoulder replacement surgeries between July 2014 and July 2015 were recruited. Patch tests were performed before the implant surgery with 10 allergens likely to be implicated in metal hypersensitivity. Postimplant patch test was performed 6 months after surgery. A majority of the patch tests were applied on the arms. RESULTS Four positive reactions were recorded in the preimplant patch tests - three positive reactions to nickel and one to chromium. Thirty patients made themselves available for the follow-up patch test. The incidence of new contact sensitivity to components of implants was 13.8% (4/29) at 6 months. One patient who had undergone knee replacement developed eczematous lesions around the knee joint after surgery. This patient tested negative to patch test at both the times. LIMITATIONS Short follow-up duration and performing patch tests on the arms, a site known to elicit less positive patch test response compared to the back in sensitized individuals, are limitations of the study. CONCLUSION There is an increase in the sensitivity to implanted components after 6 months of joint replacement surgery. The incidence of new sensitivity to a component of the implant was 13.8% (4/29). In this context, nickel is a good sensitizer and could sensitize 50% of patients who received a nickel-containing implant.
Collapse
Affiliation(s)
- Haridaran Anand Shanmugham
- Department of Dermatology, Venereology and Leprology Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Sanjeev Handa
- Department of Dermatology, Venereology and Leprology Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Dipankar De
- Department of Dermatology, Venereology and Leprology Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Mandeep Singh Dhillon
- Department of Orthopedic Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Sameer Aggarwal
- Department of Orthopedic Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| |
Collapse
|
32
|
Abstract
There are very few reports of eczema and other prosthetic-related allergic skin complications following arthroplasty. We aimed to assess the risk of eczema after joint replacement.We performed a retrospective population-based cohort study in 2024 joint replacement patients using the Longitudinal Health Insurance Database. For comparison, 8096 controls were selected, with 4 control subjects for each joint replacement patient matched for age, sex, and index year, to assess eczema risk. We examined 14-year cumulative eczema incidence associated with age, sex, immunity, disease history, and joint replacement location.Eczema rates in the joint replacement patients were 38% higher than in the control group (57.90 vs 41.84 per 1000 person-years, respectively). Compared with the control group, joint replacement patients showed a 1.35-fold increased risk of eczema according to the multivariable Cox model (95% Confidence interval [CI] = 1.23-1.49). Knee replacement patients had higher eczema risk compared with the control group (Hazard ratio [HR] = 1.45, 95% CI = 1.33-1.70). Stratified by study period, the joint replacement cohort had a higher eczema risk after the 3-month follow-up.Our study revealed that joint arthroplasty increased risk of eczema in this 14-year follow-up study, and this was not related to personal atopic history or gender.
Collapse
Affiliation(s)
- Po-Yuan Wu
- Department of Dermatology, China Medical University Hospital
- School of Medicine, China Medical University
| | | | - Chun-Hao Tsai
- School of Medicine, China Medical University
- Department of Orthopedics, China Medical University Hospital
- Department of Sports Medicine/School of Medicine, China Medical University, Taichung, Taiwan
| |
Collapse
|
33
|
Schmidt KJ, Huang PS, Colwell CW, McCauley JC, Pulido PA, Bugbee WD. Self-Reported Metal Allergy and Early Outcomes After Total Knee Arthroplasty. Orthopedics 2019; 42:330-334. [PMID: 31505017 DOI: 10.3928/01477447-20190906-01] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2018] [Accepted: 11/26/2018] [Indexed: 02/03/2023]
Abstract
The impact of self-reported metal allergy (SRMA) in total knee arthroplasty (TKA) remains controversial. In the absence of objective tests, SRMA is often used as a screening tool for implant selection. The objective of this study was to determine the effect of SRMA on early outcomes after TKA. Between 2010 and 2014, 168 patients with SRMA underwent TKA; 150 (89%) received nickel-free implants, and 18 (11%) received cobalt-chrome implants that contained nickel. Mean age was 67 years, and 95% were female. A cohort of 858 TKA patients (mean age, 68 years) without SRMA matched by sex served as the control group. Outcomes included Knee Society Score (function [KSS-F] and knee [KSS-K]), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores, knee flexion, further surgery, and complications. No differences were seen in KSS-F and KSS-K between patients with and without SRMA. The mean WOMAC pain scores were 89.1 for patients with SRMA and 85.2 for patients without SRMA (P=.030). Stiffness and physical function scores were similar. Knee flexion was similar. No differences were found between nickel-free and cobalt-chrome SRMA groups. Patients with SRMA and those without demonstrated similar early functional outcomes. Patients with SRMA who received standard cobalt-chrome implants had no significant difference in functional outcomes compared with patients with nickel-free implants. Better identifiers of patients at risk for adverse events due to implant material are needed. [Orthopedics. 2019; 42(6):330-334.].
Collapse
|
34
|
Eftekhary N, Shepard N, Wiznia D, Iorio R, Long WJ, Vigdorchik J. Metal Hypersensitivity in Total Joint Arthroplasty. JBJS Rev 2019; 6:e1. [PMID: 30516716 DOI: 10.2106/jbjs.rvw.17.00169] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Nima Eftekhary
- Department of Orthopaedic Surgery, NYU Langone Orthopaedic Hospital, New York, NY
| | | | | | | | | | | |
Collapse
|
35
|
Aggressive granulomatosis of the hip: a forgotten mode of aseptic failure. INTERNATIONAL ORTHOPAEDICS 2018; 43:1321-1328. [PMID: 30506086 DOI: 10.1007/s00264-018-4252-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Accepted: 11/25/2018] [Indexed: 02/08/2023]
Abstract
PURPOSE It has been acknowledged that implant wear correlates with the risk for periprosthetic osteolysis, being aggressive granulomatosis the worst expression of bone resorption. We sought to determine the clinical, radiological, and histological features of aggressive granulomatosis after primary total hip arthroplasty (THA). METHODS We included nine cases with aggressive granulomatosis of the hip around cemented stems. Indications for revision THA consisted of progressive signs of extensive bone resorption or implant loosening. Mean follow-up since revision THA was 143 months (SD ± 59.4). We analysed clinical outcomes, component loosening and gross as well as histological characteristics of the granulomatous lesions. RESULTS Overall mean time between primary THA and revision surgery was 81 months (SD ± 20.8). All of the cases evidenced multiple ovoid tumour-like lesions around the stem with extensive bone loss. Only one case reported thigh pain before revision surgery, with radiological evidence of stem loosening; the remaining cases were asymptomatic with well-fixed implants. Gross anatomy findings revealed metallosis in the femoral canal and inside the cystic lesions. Pathology analysis showed monocyte-macrophage-dominated adverse foreign-body-type tissue reaction with fibroblastic reactive zones and granulomatous inflammation. CONCLUSIONS We found a prevalence of 1% of this aseptic mode of implant failure. Since most of the retrieved stems were not loose, we did not find any alarming clinical symptoms anticipating implant failure. In this scenario, surgeons should be aware of the rapidly progressive nature of this entity and propose a revision THA in a timely fashion.
Collapse
|
36
|
Pohlig F, Mühlhofer HML, Harrasser N, Lenze F, Prodinger PM, von Eisenhart-Rothe R. [Metal hypersensitivity in total knee arthroplasty]. MMW Fortschr Med 2018; 160:58-60. [PMID: 30350062 DOI: 10.1007/s15006-018-1030-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Florian Pohlig
- Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, D-81675, München, Deutschland.
| | - Heinrich Maria Laurentius Mühlhofer
- Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, D-81675, München, Deutschland
| | - Norbert Harrasser
- Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, D-81675, München, Deutschland
| | - Florian Lenze
- Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, D-81675, München, Deutschland
| | - Peter Michael Prodinger
- Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, D-81675, München, Deutschland
| | - Rüdiger von Eisenhart-Rothe
- Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, D-81675, München, Deutschland
| |
Collapse
|
37
|
Arnholt CM, MacDonald DW, Klein GR, Cates HE, Rimnac CM, Kurtz SM, the Implant Research Center Writing Committee, Kocagoz S, Chen AF. What Is the Incidence of Cobalt-Chromium Damage Modes on the Bearing Surface of Contemporary Femoral Component Designs for Total Knee Arthroplasty? J Arthroplasty 2018; 33:3313-3319. [PMID: 29871834 PMCID: PMC6146069 DOI: 10.1016/j.arth.2018.05.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Revised: 04/25/2018] [Accepted: 05/10/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study was to determine the incidence of metal release in contemporary total knee arthroplasty and the patient-related factors associated with this release. METHODS In total, 256 retrieved cobalt-chromium femoral components were collected through a multi-institutional orthopedic implant retrieval program (implanted: 1-15 years). Implants were mainly revised for loosening (84/256), instability (62/256), and infection (46/256). Third-body damage was assessed using a semiquantitative scoring method. Microscale electro-corrosion damage (MECD) was evaluated using digital optical microscopy. Radii of curvature were measured from representative components to calculate anterior-posterior and medial-lateral ratios. Femoral component surface roughness was measured using a white light interferometer. Using a multivariable linear model, associations between damage score, implant, and patient factors were tested. Spearman's ρ correlation tests were performed to determine the association between roughness measurements and damage score. RESULTS Mild to severe damage was observed in 52% (134/256) of the components. In the multivariable linear model, anterior-posterior ratio (β = -8.07; P < .001), loosening (β = -0.52; P = .006), and patient weight (β = 0.01; P = .007) were associated with damage score. Suspected MECD damage was observed in 82% (209/256) of components. The Ra value (ρ = 0.196; P = .002) and Rq value (ρ = 0.157; P = .012) increased as the damage score increased. CONCLUSION The findings of this retrieval study support that similar damage mechanisms exist in contemporary and long-term total knee arthroplasty devices. Additionally, we observed associations between loosening, anterior-posterior conformity, and patient weight with increased surface damage.
Collapse
Affiliation(s)
- Christina M. Arnholt
- Implant Research Center, Drexel University, 3401 Market Street, Suite 345, Philadelphia, PA 19104
| | - Daniel W. MacDonald
- Implant Research Center, Drexel University, 3401 Market Street, Suite 345, Philadelphia, PA 19104
| | - Gregg R. Klein
- Hartzband Center for Hip & Knee Replacement, Paramus, NJ
| | | | - Clare M. Rimnac
- Department of Mechanical and Aerospace Engineering and the Center for the Evaluation of Implant Performance, Case Western Reserve University, 10900 Euclid Ave., Cleveland, Ohio 44106
| | - Steven M. Kurtz
- Implant Research Center, Drexel University, 3401 Market Street, Suite 345, Philadelphia, PA 19104,Exponent, Inc., 3440 Market Street, Suite 600, Philadelphia, PA 19104
| | | | - Sevi Kocagoz
- Implant Research Center, Drexel University, 3401 Market Street, Suite 345, Philadelphia, PA 19104
| | - Antonia F. Chen
- Brigham and Women’s Hospital, Department of Orthopaedics, Harvard Medical School, Boston, MA 02115
| |
Collapse
|
38
|
Puente Reyna AL, Fritz B, Schwiesau J, Schilling C, Summer B, Thomas P, Grupp TM. Metal ion release barrier function and biotribological evaluation of a zirconium nitride multilayer coated knee implant under highly demanding activities wear simulation. J Biomech 2018; 79:88-96. [DOI: 10.1016/j.jbiomech.2018.07.043] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 07/20/2018] [Accepted: 07/31/2018] [Indexed: 12/13/2022]
|
39
|
Phedy P, Djaja YP, Boedijono DR, Wahyudi M, Silitonga J, Solichin I. Hypersensitivity to orthopaedic implant manifested as erythroderma: Timing of implant removal. Int J Surg Case Rep 2018; 49:110-114. [PMID: 30005360 PMCID: PMC6037004 DOI: 10.1016/j.ijscr.2018.06.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 06/06/2018] [Accepted: 06/16/2018] [Indexed: 12/12/2022] Open
Abstract
INTRODUCTION Incidence of hypersensitivity to orthopaedic implant, once estimated in less than 1% of population, recently has increased to 10%. Controversies about the timing of implant removal remain, especially due to the fact that implant hypersensitivity may be a contributing factor to implant failure. We present a case report and literature reviews to establish the decision making for the timing of implant removal in the presence of implant hypersensitivity. PRESENTATION OF CASE Female, 42 years old with nonunion of mid-shaft tibia and fibula which was treated with ORIF with conventional SAE16 stainless steel plate and bone graft. A week after, she developed a generalized rash, which is later diagnosed as erythroderma, that relapsed despite adequate systemic corticosteroid. Poor healing of surgical site wound were marked. After the implant removal, the cutaneous condition improved and no relapse were found. DISCUSSION Management of hypersensitivity to implants involved corticosteroid administration, removal or replacement of implants, or implants coating with polytetrafluoroethylene. Currently there are no specific guidelines regulating the management of implant allergy based on the timing of the onset, especially in fracture cases. The decision-making would be straightforward if union was already achieved. Otherwise, controversies would still occur. In this paper, we proposed an algorithm regarding the steps in managing metal allergy due to implant in fracture cases. CONCLUSION Despite the concerns regarding implant survival in hypersensitivity cases, the decision whether the implant should be removed or replaced should be based on the time and condition of the fracture healing process.
Collapse
Affiliation(s)
- Phedy Phedy
- Department of Orthopaedic and Traumatology, Fatmawati General Hospital, Jakarta, Indonesia.
| | - Yoshi P Djaja
- Department of Orthopaedic and Traumatology, Fatmawati General Hospital, Jakarta, Indonesia.
| | - Dimas R Boedijono
- Department of Orthopaedic and Traumatology, Fatmawati General Hospital, Jakarta, Indonesia.
| | - Muhammad Wahyudi
- Department of Orthopaedic and Traumatology, Fatmawati General Hospital, Jakarta, Indonesia.
| | - Jamot Silitonga
- Department of Orthopaedic and Traumatology, Fatmawati General Hospital, Jakarta, Indonesia.
| | - Iman Solichin
- Rumah Sakit Orthopaedi Purwokerto, Purwokerto, Indonesia.
| |
Collapse
|
40
|
Furrer S, Scherer Hofmeier K, Grize L, Bircher AJ. Metal hypersensitivity in patients with orthopaedic implant complications-A retrospective clinical study. Contact Dermatitis 2018; 79:91-98. [PMID: 29888396 DOI: 10.1111/cod.13032] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 04/15/2018] [Accepted: 04/19/2018] [Indexed: 12/29/2022]
Abstract
BACKGROUND Hypersensitivity to metals as a cause of implant-related complications has been a subject of controversy. Projections indicate an increase in the frequency of joint replacements of between 300% and 600% by the year 2030; therefore, this issue is of considerable interest. OBJECTIVE To evaluate sensitization to implant materials in patients with implant-related complications, to identify allergens, and to clarify whether hypersensitivity is a relevant cause. METHODS Patients with implant-related complications or a positive history of contact allergy and planned total joint replacements referred for allergological investigation between 2004 and 2017 were retrospectively analysed. RESULTS In total, 311 patients were included. A positive patch test reaction to a metal was seen in 64.4% of preoperative patients and in 54.6% of patients with implant-related complications. Common alloy metals such as cobalt, chromium and titanium gave positive reactions in up to 2.9% of patients with implant-related complications. None of the patients with skin changes had a positive patch test reaction to an implant metal. CONCLUSION Other factors, such as the type of replaced joint and mechanical stress, seem to be more relevant for implant-related complications. Sensitization to metals or other materials seems to rarely play a role, and is overestimated.
Collapse
Affiliation(s)
- Stefan Furrer
- Department of Dermatology, Allergy Unit, University Hospital, Basel, Switzerland
| | | | - Leticia Grize
- Swiss Tropical and Public Health Institute, Basel, Switzerland.,University of Basel, Basel, Switzerland
| | - Andreas J Bircher
- Department of Dermatology, Allergy Unit, University Hospital, Basel, Switzerland.,University of Basel, Basel, Switzerland
| |
Collapse
|
41
|
Akil S, Newman JM, Shah NV, Ahmed N, Deshmukh AJ, Maheshwari AV. Metal hypersensitivity in total hip and knee arthroplasty: Current concepts. J Clin Orthop Trauma 2018; 9:3-6. [PMID: 29628676 PMCID: PMC5884053 DOI: 10.1016/j.jcot.2017.10.003] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 10/04/2017] [Accepted: 10/05/2017] [Indexed: 01/23/2023] Open
Abstract
Metal hypersensitivity (MHS) is a rare complication of total joint arthroplasty that has been linked to prosthetic device failure when other potential causes have been ruled out. The purpose of this review was to conduct an analysis of existing literature in order to get a better understanding of the pathophysiology, presentation, diagnosis, and management of MHS. It has been described as a type IV hypersensitivity reaction to the metals comprising prosthetic implants, often nickel and cobalt-chromium. Patients suffering from this condition have reported periprosthetic joint pain and swelling as well as cutaneous, eczematous dermatitis. There is no standard for diagnosis MHS, but tests such as patch testing and lymphocyte transformation testing have demonstrated utility, among others. Treatment options that have demonstrated success include administration of steroids and revision surgery, in which the existing metal implant is replaced with one of less allergenic materials. Moreover, the definitive resolution of symptoms has most commonly required revision surgery with the use of different implants. However, more studies are needed in order to understand the complexity of this subject.
Collapse
Affiliation(s)
- Samuel Akil
- Department of Orthopaedic Surgery, State University of New York (SUNY), Downstate Medical Center, Brooklyn, NY, USA
| | - Jared M. Newman
- Department of Orthopaedic Surgery, State University of New York (SUNY), Downstate Medical Center, Brooklyn, NY, USA
| | - Neil V. Shah
- Department of Orthopaedic Surgery, State University of New York (SUNY), Downstate Medical Center, Brooklyn, NY, USA
| | - Natasha Ahmed
- Saba University School of Medicine, Saba, Caribbean Netherlands, Netherlands
| | - Ajit J. Deshmukh
- Department of Orthopaedic Surgery, NYU Langone Medical Center, VA New York Harbor Healthcare System, New York, NY, USA
| | - Aditya V. Maheshwari
- Department of Orthopaedic Surgery, State University of New York (SUNY), Downstate Medical Center, Brooklyn, NY, USA,Correspondence to: Adult Reconstruction and Musculoskeletal Oncology Divisions SUNY Downstate Medical Center 450 Clarkson Ave., Box 30 Brooklyn, New York 11203, USA.
| |
Collapse
|
42
|
Ko JWK, Nicholson TA, Hoffler CE, Williams G, Getz C. Metal Allergy as a Cause of Implant Failure in Shoulder Arthroplasty. Orthopedics 2017; 40:e844-e848. [PMID: 28776630 DOI: 10.3928/01477447-20170719-01] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Accepted: 06/13/2017] [Indexed: 02/03/2023]
Abstract
Metal allergy is an uncommon and poorly understood cause of failure of orthopedic implants. To the authors' knowledge, there have been no reports of the management of shoulder arthroplasty patients with metal allergy. The authors present their experience with the diagnosis and management of patients with metal allergy. Patients with metal allergy undergoing shoulder arthroplasty were identified through retrospective chart review from January 1, 2012, to January 31, 2015. Case characteristics collected included patient risk factors (age, sex, prior cutaneous reactions to metal), metal allergy factors (type of metal allergy, method of diagnosis), and surgery factors (implant type, primary/revision, type of shoulder arthroplasty). Outcomes measured included American Shoulder and Elbow Surgeons score, Penn Shoulder Score, and Single Assessment Numeric Evaluation score. Eleven patients were identified with metal allergy. Five were diagnosed prior to the index arthroplasty, and 6 were diagnosed after shoulder replacement. The diagnosis was made through skin patch testing, memory lymphocyte immunostimulation assay, or clinical history. Patients identified after implantation presented with progressive pain and stiffness, but none had cutaneous manifestations. Patients with metal allergy had better results undergoing primary shoulder arthroplasty than undergoing revision. Metal allergy is rare but may be a clinically significant cause of unsatisfactory shoulder arthroplasty. Given the superior results of primary shoulder arthroplasty compared with revision, screening for metal allergy by clinical history is recommended. [Orthopedics. 2017; 40(5):e844-e848.].
Collapse
|
43
|
Wawrzynski J, Gil JA, Goodman AD, Waryasz GR. Hypersensitivity to Orthopedic Implants: A Review of the Literature. Rheumatol Ther 2017; 4:45-56. [PMID: 28364382 PMCID: PMC5443731 DOI: 10.1007/s40744-017-0062-6] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Indexed: 12/18/2022] Open
Abstract
Awareness of rare etiologies for implant failure is becoming increasingly important. In addition to the overall increase in joint arthroplasties, revision surgeries are projected to increase dramatically in the coming years, with volume increasing up to seven-fold between 2005 and 2030. The literature regarding the relationship between metal allergy and implant failure is controversial. It has proven difficult to determine whether sensitization is a cause or a consequence of implant failure. Testing patients with functional implants is not a clinically useful approach, as the rate of hypersensitivity is higher in implant recipients than in the general population, regardless of the status of the implant. As a result of the ineffectiveness of preoperative patch testing for predicting adverse outcomes, as well as the high cost of implementing such patch testing as standard procedure, most orthopedists and dermatologists agree that an alternative prosthesis should only be considered for patients with a history of allergy to a metal in the standard implant. In patients with a failed implant requiring revision surgery, hypersensitivity to an implant component should be considered in the differential diagnosis. Because a metal allergy to implant components is currently not commonly considered in the differential for joint failure in the orthopedic literature, there should be improved communication and collaboration between orthopedists and dermatologists when evaluating joint replacement patients with a presentation suggestive of allergy.
Collapse
Affiliation(s)
| | - Joseph A Gil
- Department of Orthopaedic Surgery, Warren Alpert Medical School, Brown University, Providence, RI, USA.
| | - Avi D Goodman
- Department of Orthopaedic Surgery, Warren Alpert Medical School, Brown University, Providence, RI, USA
| | - Gregory R Waryasz
- Department of Orthopaedic Surgery, Warren Alpert Medical School, Brown University, Providence, RI, USA
| |
Collapse
|
44
|
Thomsen M, Krenn V, Thomas P. [Adverse reactions to metal orthopedic implants after knee arthroplasty]. Hautarzt 2017; 67:347-51. [PMID: 27116434 DOI: 10.1007/s00105-016-3793-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Based on several clinical examples, the range of adverse or hypersensitive reactions to metal implants especially after total knee replacement are presented. In general, we found the patients to generally be women who present with pain, swelling, and local or generalized eczema. Some also present with early aseptic loosening mainly in the first 4 years after implantation. For these patients, a detailed allergy-specific history should be taken and a patch test should be performed; if necessary, blood ion levels should be evaluated to exclude cobaltism. Before revision surgery and exchange of the implant we always perform arthroscopic inspection to obtain biopsies for microbiology and histopathology. Using the Consensus Classification a good evaluation for planning revision with the different implant options is possible.
Collapse
Affiliation(s)
- M Thomsen
- Klinik für Orthopädie und Unfallchirurgie, Klinikum Mittelbaden Baden-Baden, Balger Str. 50, 76532, Baden-Baden, Deutschland.
| | - V Krenn
- Zentrum für Histologie, Zytologie und Molekulare Diagnostik, Max-Planck-Str. 5, 54296, Trier, Deutschland
| | - P Thomas
- Klinik und Poliklinik für Dermatologie und Allergologie, Ludwig-Maximilians-Universität München, Frauenlobstr. 9-11, 80337, München, Deutschland
| |
Collapse
|
45
|
Teo WZW, Schalock PC. Metal Hypersensitivity Reactions to Orthopedic Implants. Dermatol Ther (Heidelb) 2017; 7:53-64. [PMID: 27995484 PMCID: PMC5336431 DOI: 10.1007/s13555-016-0162-1] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Indexed: 01/08/2023] Open
Abstract
Total hip and knee replacement surgery using metal alloy devices is common. Type IV allergic reactions to these implants occur, though infrequently. While uncommon, peri-implant metal allergic reactions may cause significant morbidity for the affected individual-including aseptic loosening, pseudotumor formation and frank device failure. It is challenging to predict who will have these reactions, even in those with established pre-implant metal allergy. At this time, the scientific literature clearly supports few conclusions. Despite this, we believe several conclusions can be made: routine pre-implant testing in asymptomatic individuals is not indicated; listen to patient's concerns about metal allergy if the concern arises; patch testing is probably the best pre- and post-implant screening test; post-implantation testing is controversial and even positive LTT or patch test does not definitively diagnose morbidity from a metal allergy; and complete recovery following revision placement of an immunologically inert device is diagnostic. More research is needed to scientifically approach this issue.
Collapse
Affiliation(s)
- Wendy Z W Teo
- Department of Surgery (Dermatology), Geisel School of Medicine at Dartmouth, Hanover, NH, USA
| | - Peter C Schalock
- Department of Surgery (Dermatology), Geisel School of Medicine at Dartmouth, Hanover, NH, USA.
| |
Collapse
|
46
|
Abstract
BACKGROUND There is little data on whether preexisting allergies to implant materials and bone cement have an impact on the outcome of TKA. QUESTIONS/PURPOSES This review article analyzes the current literature to evaluate the prevalence and importance of metal and cement allergies for patients undergoing total knee arthroplasty. METHODS A review of the literature was performed using the following search criteria: "knee," "arthroplasty," and "allergy" as well as "knee," "arthroplasty," and "hypersensitivity." RESULTS One hundred sixteen articles were identified on PubMed, Seventy articles could be excluded by reviewing the title and abstract leaving 46 articles to be included for this review. The majority of the studies cited patch testing as the gold standard for screening and diagnosis of hypersensitivity following TKA. There is consensus that patients with self-reported allergies against metals or bone cement and positive patch test should be treated with hypoallergenic materials or cementless TKA. Treatment options include the following: coated titanium or cobalt-chromium implants, ceramic, or zirconium oxide implants. CONCLUSION Allergies against implant materials and bone cement are rare. Patch testing is recommended for patients with self-reported allergies. The use of special implants is recommended for patients with a confirmed allergy.
Collapse
|
47
|
Lohmann CH, Hameister R, Singh G. Allergies in orthopaedic and trauma surgery. Orthop Traumatol Surg Res 2017; 103:S75-S81. [PMID: 28043850 DOI: 10.1016/j.otsr.2016.06.021] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Revised: 05/26/2016] [Accepted: 06/07/2016] [Indexed: 02/02/2023]
Abstract
Hypersensitivity reactions to implants in orthopaedic and trauma surgery are a rare but devastating complication. They are considered as a delayed-type of hypersensitivity reaction (type IV), characterized by an antigen activation of sensitized T-lymphocytes releasing various cytokines and may result in osteoclast activation and bone resorption. Potential haptens are originated from metal alloys or bone-cement. A meta-analysis has confirmed a higher probability of developing a metal hypersensitivity postoperatively and noted a greater risk of failed replacements compared to stable implants. Hypersensitivity to implants may present with a variety of symptoms such as pain, joint effusion, delayed wound/bone healing, persistent secretion, allergic dermatitis (localized or systemic), clicking noises, loss of joint function, instability and failure of the implant. Various diagnostic options have been offered, including patch testing, metal alloy patch testing, histology, lymphocyte transformation test (LTT), memory lymphocyte immunostimulation assay (MELISA), leukocyte migration inhibition test (LIF) and lymphocyte activation test (LAT). No significant differences between in vivo and in vitro methods have been found. Due to unconvincing evidence for screening methods, predictive tests are not recommended for routine performance. Infectious aetiology always needs to be excluded. As there is a lack of evidence on large-scale studies with regards to the optimal treatment option, management currently relies on individual case-by-case decisions. Several options for patients with (suspected) metal-related hypersensitivity exist and may include materials based on ceramic, titanium or oxinium or modified surfaces. Promising results have been reported, but long-term experience is lacking. More large-scaled studies are needed in this context. In patients with bone-cement hypersensitivity, the component suspected for hypersensitivity should be avoided. The development of (predictive) biomarkers is considered as a major contribution for the future.
Collapse
Affiliation(s)
- C H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 44, Leipziger Strasse, 39120 Magdeburg, Germany.
| | - R Hameister
- Department of Orthopaedic Surgery, Otto-von-Guericke University, 44, Leipziger Strasse, 39120 Magdeburg, Germany; Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, 4, Medical Drive, 117594, Singapore
| | - G Singh
- Division of Musculoskeletal Oncology, University Orthopaedics, Hand and Reconstructive Microsurgery Cluster, National University Health System, 1E, Kent Ridge Road, 119228, Singapore
| |
Collapse
|
48
|
Metallosis Presenting as a Progressive Neurologic Deficit Four Years After a Posterior Spinal Fusion for Adolescent Idiopathic Scoliosis: A Case Report. Spine (Phila Pa 1976) 2017; 42:E56-E59. [PMID: 27172284 DOI: 10.1097/brs.0000000000001685] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN A case report. OBJECTIVE The aim of this study was to report a case of progressive pain and paraparesis secondary to metallosis four years after a pediatric posterior spinal fusion (PSF). SUMMARY OF BACKGROUND DATA Metallosis as a late complication of pediatric spinal surgery is rarely reported. Myelographic computed tomography (CT) can be helpful in establishing the diagnosis. The use of serum chromium levels as a means of definitive diagnosis has been suggested, but has only been reported retrospectively. METHODS A 19-year-old male presented four years after PSF for adolescent idiopathic scoliosis with sudden onset of pain and neurologic deficits. Radiographs and CT scan suggested infection. Intraoperatively, no purulent material was noted, but black and yellowish corrosive debris was found around the right L1 pedicle screw, so it was removed and the cavity packed with tobramycin impregnated calcium sulfate beads. After surgery, neurologic deficits worsened. CT myelogram showed irregular opacification of the thecal sac at the level of the conus. A posterior laminectomy and decompression was performed with removal of all debris and spinal instrumentation. Metallosis within the spinal canal was noted and serum chromium levels were obtained. RESULTS The patient was discharged one week after admission with improvement of pain and gradual improvement in neurologic examination. Three years postdischarge, the patient is asymptomatic and examination shows bilateral clonus. Serum chromium levels declined from a high of 4.5 μg/L operatively to 0.8 at final follow-up (normal: 0.2-0.6 μg/L). CONCLUSION Although uncommon, metallosis should be considered in the differential diagnosis of any late presenting case of pain, infection-like symptoms, or neurologic deficits after pediatric PSF. CT myelography and serum chromium levels may help guide diagnosis; however, surgical exploration is needed for definitive diagnosis and treatment. LEVEL OF EVIDENCE 4.
Collapse
|
49
|
Craig R, Vlychou M, McCarthy CL, Gibbons CLMH, Athanasou NA. Metal wear-induced pseudotumour following an endoprosthetic knee replacement for Ewing sarcoma. Skeletal Radiol 2017; 46:967-974. [PMID: 28271180 PMCID: PMC5438826 DOI: 10.1007/s00256-017-2610-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Revised: 01/19/2017] [Accepted: 02/14/2017] [Indexed: 02/08/2023]
Abstract
Pseudotumours are well recognised as a complication of metal-on-metal hip arthroplasties and are thought to develop on the basis of an innate and adaptive immune response to cobalt-chrome (Co-Cr) wear particles. We report a case of a large pseudotumour that developed following a knee endoprosthetic replacement (EPR) undertaken for Ewing sarcoma. The lesion contained necrotic and degenerate connective tissue in which there were numerous scattered metal wear-containing macrophages, eosinophil polymorphs, lymphocytes, plasma cells and aseptic lymphocyte-dominated vascular-associated lesion-like lymphoid aggregates. Metal ion levels were elevated. No evidence of infection or tumour was noted and it was concluded that the lesion was most likely an inflammatory pseudotumour developing on the basis of an innate and adaptive immune response to components of Co-Cr metal wear derived from the knee EPR.
Collapse
Affiliation(s)
- Richard Craig
- Department of Orthopaedics, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK
| | - Marianna Vlychou
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Department of Histopathology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK
| | - Catherine L McCarthy
- Department of Radiology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK
| | | | - N A Athanasou
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Department of Histopathology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK.
| |
Collapse
|
50
|
Brahimaj B, Lamba M, Breneman JC, Warnick RE. Iodine-125 seed migration within brain parenchyma after brachytherapy for brain metastasis: case report. J Neurosurg 2016; 125:1167-1170. [DOI: 10.3171/2015.11.jns151464] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
This case report documents the migration of 3 iodine-125 (125I) seeds from the tumor resection cavity into brain parenchyma over a 7-year period. A 66-year-old woman had a history of metastatic ovarian carcinoma, nickel allergy, and reaction to a titanium hip implant that required reoperation for hardware removal. In this unique case of parenchymal migration, the seed paths seemed to follow white matter tracts, traveling between 18.5 and 35.5 mm from the initial implant site. The patient's initial neurological decline, which was thought to be related to radiation necrosis, appeared to stabilize with medical therapy. She subsequently developed progressive right hemispheric edema that resulted in neurological deterioration and death. Considering her previous reactions to nickel and titanium, the authors now speculate that her later clinical course reflected an allergic reaction to the titanium casing of the 125I seeds. Containing a trace amount of nickel, 125I seeds can elicit a delayed hypersensitivity reaction in patients with a history of nickel dermatitis. Preoperative patch testing is recommended in these patients, and 125I seed implantation should be avoided in those who test positive.
Collapse
Affiliation(s)
- Bledi Brahimaj
- 1Department of Neurosurgery, Rush University Medical Center, Chicago, Illinois;
| | - Michael Lamba
- Departments of 2Radiation Oncology and
- 4Brain Tumor Center at University of Cincinnati Neuroscience Institute; and
| | - John C. Breneman
- Departments of 2Radiation Oncology and
- 4Brain Tumor Center at University of Cincinnati Neuroscience Institute; and
| | - Ronald E. Warnick
- 3Neurosurgery, University of Cincinnati College of Medicine
- 4Brain Tumor Center at University of Cincinnati Neuroscience Institute; and
- 5Mayfield Clinic, Cincinnati, Ohio
| |
Collapse
|