1
|
Kremer NI, van Laar T, Lange SF, Statius Muller S, la Bastide-van Gemert S, Oterdoom DM, Drost G, van Dijk JMC. STN-DBS electrode placement accuracy and motor improvement in Parkinson's disease: systematic review and individual patient meta-analysis. J Neurol Neurosurg Psychiatry 2023; 94:236-244. [PMID: 36207065 DOI: 10.1136/jnnp-2022-329192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 09/21/2022] [Indexed: 11/05/2022]
Abstract
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective neurosurgical treatment for Parkinson's disease. Surgical accuracy is a critical determinant to achieve an adequate DBS effect on motor performance. A two-millimetre surgical accuracy is commonly accepted, but scientific evidence is lacking. A systematic review and meta-analysis of study-level and individual patient data (IPD) was performed by a comprehensive search in MEDLINE, EMBASE and Cochrane Library. Primary outcome measures were (1) radial error between the implanted electrode and target; (2) DBS motor improvement on the Unified Parkinson's Disease Rating Scale part III (motor examination). On a study level, meta-regression analysis was performed. Also, publication bias was assessed. For IPD meta-analysis, a linear mixed effects model was used. Forty studies (1391 patients) were included, reporting radial errors of 0.45-1.86 mm. Errors within this range did not significantly influence the DBS effect on motor improvement. Additional IPD analysis (206 patients) revealed that a mean radial error of 1.13±0.75 mm did not significantly change the extent of DBS motor improvement. Our meta-analysis showed a huge publication bias on accuracy data in DBS. Therefore, the current literature does not provide an unequivocal upper threshold for acceptable accuracy of STN-DBS surgery. Based on the current literature, DBS-electrodes placed within a 2 mm range of the intended target do not have to be repositioned to enhance motor improvement after STN-DBS for Parkinson's disease. However, an indisputable upper cut-off value for surgical accuracy remains to be established. PROSPERO registration number is CRD42018089539.
Collapse
Affiliation(s)
- Naomi I Kremer
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - Teus van Laar
- Neurology, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - Stèfan F Lange
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - Sijmen Statius Muller
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | | | - Dl Marinus Oterdoom
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - Gea Drost
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
- Neurology, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| | - J Marc C van Dijk
- Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
| |
Collapse
|
2
|
Kawasaki T, Kikuchi T, Otani K, Mitsuno Y, Yamao Y, Sawamoto N, Takahashi R, Miyamoto S. Intraoperative cone-beam CT with metal artifact reduction for assessment of the electrode position and the intracranial structures during deep brain stimulation procedure. Acta Neurochir (Wien) 2022; 164:2309-2316. [PMID: 35851925 DOI: 10.1007/s00701-022-05313-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 07/08/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND In deep brain stimulation (DBS) for Parkinson's disease (PD), the clinical outcome largely depends on the appropriate position of the electrode implanted in the targeted structure. In intraoperative cone-beam computed tomography (CT) performed for the evaluation of the electrode position, the metal artifact induced by the implanted electrode can prevent the precise localization of the electrode. Metal artifact reduction (MAR) techniques have been recently developed that can dramatically improve the visualization of objects by reducing metal artifacts after performing cone-beam CT. Hence, in this case series, we attempted to clarify the usefulness and accuracy of intraoperative cone-beam CT with MAR (intraCBCTwM) by comparing with both intraoperative cone-beam CT without MAR (intraCBCTwoM) and conventional postoperative CT (post-CT) for the assessment of the implanted electrode position and the intracranial structures during DBS procedures. METHODS Between November 2019 and December 2020, 10 patients with PD who underwent DBS at our institution were recruited, and the images of 9 patients (bilateral: n = 8, unilateral: n = 1) were analyzed. The artifact index (AI) in intraCBCTwM or intraCBCTwoM, and conventional post-CT were retrospectively assessed using the standard deviation of the region-of-interest around the implanted electrodes and background noise. Additionally, the Euclidean distances gap of electrode tip based on post-CT in each fusion image was compared between intraCBCTwM and intraCBCTwoM. RESULTS The AI was significantly lower in intraCBCTwM than in intraCBCTwoM (P < 0.01). The mean Euclidean distance between the tip of the electrode in intraCBCTwM and in post-CT was significantly shorter compared to that in intraCBCTwoM (P < 0.05). CONCLUSIONS The results reported here suggest that intraCBCTwM is a more useful and accurate method than intraCBCTwoM to assess the implanted electrode position and intracranial structures during DBS.
Collapse
Affiliation(s)
- Toshinari Kawasaki
- Department of Neurosurgery, Kyoto University Graduate School of Medicine, 54 Shogoinn Kawahara-cho, Sakyo-ku, Kyoto, Kyoto, 606-8507, Japan.,Department of Neurosurgery, Otsu City Hospital, Shiga, Japan
| | - Takayuki Kikuchi
- Department of Neurosurgery, Kyoto University Graduate School of Medicine, 54 Shogoinn Kawahara-cho, Sakyo-ku, Kyoto, Kyoto, 606-8507, Japan.
| | | | - Yuto Mitsuno
- Department of Neurosurgery, Kyoto University Graduate School of Medicine, 54 Shogoinn Kawahara-cho, Sakyo-ku, Kyoto, Kyoto, 606-8507, Japan
| | - Yukihiro Yamao
- Department of Neurosurgery, Kyoto University Graduate School of Medicine, 54 Shogoinn Kawahara-cho, Sakyo-ku, Kyoto, Kyoto, 606-8507, Japan
| | - Nobukatsu Sawamoto
- Department of Human Health Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Ryosuke Takahashi
- Department of Neurology, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Susumu Miyamoto
- Department of Neurosurgery, Kyoto University Graduate School of Medicine, 54 Shogoinn Kawahara-cho, Sakyo-ku, Kyoto, Kyoto, 606-8507, Japan
| |
Collapse
|
3
|
Baptista TS, Rito M, Chamadoira C, Rocha LF, Evans G, Cunha JPS. Towards a Closed-loop Neuro-Robotic Approach to DBS Electrode Implantation based on Real-Time Wrist Rigidity Evaluation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:4830-4833. [PMID: 36086618 DOI: 10.1109/embc48229.2022.9871792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The iHandU system is a wearable device that quantitatively evaluates changes in wrist rigidity during Deep Brain Stimulation (DBS) surgery, allowing clinicians to find optimal stimulation settings that reduce patient symptoms. Robotic accuracy is also especially relevant in DBS surgery, as accurate electrode placement is required to increase effectiveness and reduce side effects. The main goal of this work is to integrate the advantages of each system in a closed-loop system between an industrial robot and the iHandU system. For this purpose, a comparative analysis of a Leksell stereotactic frame and neuro-robotic system accuracies was performed using a lab-made phantom. The neuro-robotic system reached 90% of trajectories, while the stereotactic frame reached all trajectories. There are significant differences in accuracy errors between these trajectories (p < 0.0001), which can be explained by the high correlation between the neuro-robotic system errors and the distance from the trajectory to the origin of the Leksell coordinate system (ρ = 0.72). Overall accuracy is comparable to existing neuro-robotic systems, achieving a deviation of (1.0 ± 0.5) mm at the target point. The accuracy of DBS electrode positioning and stimulation parameters choice leads to better long-term clinical outcomes in Parkinson's disease patients. Our neuro-robotic system combines real-time feedback assessment of the patient's symptomatic response and automatic positioning of the DBS electrode in a specific brain area.
Collapse
|
4
|
Rusche T, Kaufmann J, Voges J. Nucleus accumbens projections: Validity and reliability of fiber reconstructions based on high-resolution diffusion-weighted MRI. Hum Brain Mapp 2021; 42:5888-5910. [PMID: 34528323 PMCID: PMC8596959 DOI: 10.1002/hbm.25657] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 08/02/2021] [Accepted: 08/29/2021] [Indexed: 12/17/2022] Open
Abstract
Clinical effects of deep brain stimulation are largely mediated by the activation of myelinated axons. Hence, increasing attention has been paid in the past on targeting white matter tracts in addition to gray matter. Aims of the present study were: (i) visualization of discrete afferences and efferences of the nucleus accumbens (NAc), supposed to be a major hub of neural networks relating to mental disorders, using probabilistic fiber tractography and a data driven approach, and (ii) validation of the applied methodology for standardized routine clinical applications. MR‐data from 11 healthy subjects and 7 measurement sessions each were acquired on a 3T MRI‐scanner. For probabilistic fiber tracking the NAc as a seed region and the medial prefrontal cortex (mPFC), anterior cingulate cortex (ACC), amygdala (AMY), hippocampus (HPC), dorsomedial thalamus (dmT) and ventral tegmental area (VTA) as target regions were segmented for each subject and both hemispheres. To quantitatively assess the reliability and stability of the reconstructions, we filtered and clustered the individual fiber‐tracts (NAc to target) for each session and subject and performed a point‐by‐point calculation of the maximum cluster distances for intra‐subject comparison. The connectivity patterns formed by the obtained fibers were in good concordance with published data from tracer and/or fiber‐dissection studies. Furthermore, the reliability assessment of the (NAc to target)‐fiber‐tracts yielded to high correlations between the obtained clustered‐tracts. Using DBS with directional lead technology, the workflow elaborated in this study may guide selective electrical stimulation of NAc projections.
Collapse
Affiliation(s)
- Thilo Rusche
- Department of Stereotactic Neurosurgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.,Department of Radiology, Clinic of Radiology & Nuclear Medicine, University Hospital Basel, University Basel, Basel, Switzerland
| | - Jörn Kaufmann
- Department of Neurology, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - Jürgen Voges
- Department of Stereotactic Neurosurgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| |
Collapse
|
5
|
Park HR, Lim YH, Song EJ, Lee JM, Park K, Park KH, Lee WW, Kim HJ, Jeon B, Paek SH. Bilateral Subthalamic Nucleus Deep Brain Stimulation under General Anesthesia: Literature Review and Single Center Experience. J Clin Med 2020; 9:jcm9093044. [PMID: 32967337 PMCID: PMC7564882 DOI: 10.3390/jcm9093044] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 09/13/2020] [Accepted: 09/17/2020] [Indexed: 02/07/2023] Open
Abstract
Bilateral subthalamic nucleus (STN) Deep brain stimulation (DBS) is a well-established treatment in patients with Parkinson's disease (PD). Traditionally, STN DBS for PD is performed by using microelectrode recording (MER) and/or intraoperative macrostimulation under local anesthesia (LA). However, many patients cannot tolerate the long operation time under LA without medication. In addition, it cannot be even be performed on PD patients with poor physical and neurological condition. Recently, it has been reported that STN DBS under general anesthesia (GA) can be successfully performed due to the feasible MER under GA, as well as the technical advancement in direct targeting and intraoperative imaging. The authors reviewed the previously published literature on STN DBS under GA using intraoperative imaging and MER, focused on discussing the technique, clinical outcome, and the complication, as well as introducing our single-center experience. Based on the reports of previously published studies and ours, GA did not interfere with the MER signal from STN. STN DBS under GA without intraoperative stimulation shows similar or better clinical outcome without any additional complication compared to STN DBS under LA. Long-term follow-up with a large number of the patients would be necessary to validate the safety and efficacy of STN DBS under GA.
Collapse
Affiliation(s)
- Hye Ran Park
- Department of Neurosurgery, Soonchunhyang University Seoul Hospital, Seoul 04401, Korea;
| | - Yong Hoon Lim
- Department of Neurosurgery, Seoul National University Hospital, Seoul 03080, Korea; (Y.H.L.); (E.J.S.)
| | - Eun Jin Song
- Department of Neurosurgery, Seoul National University Hospital, Seoul 03080, Korea; (Y.H.L.); (E.J.S.)
| | - Jae Meen Lee
- Department of Neurosurgery, Pusan National University Hospital, Busan 49241, Korea;
| | - Kawngwoo Park
- Department of Neurosurgery, Gachon University Gil Medical Center, Incheon 21565, Korea;
| | - Kwang Hyon Park
- Department of Neurosurgery, Chuungnam National University Sejong Hospital, Sejong 30099, Korea;
| | - Woong-Woo Lee
- Department of Neurology, Nowon Eulji Medical Center, Eulji University, Seoul 01830, Korea;
| | - Han-Joon Kim
- Department of Neurology, Seoul National University Hospital, Seoul 03080, Korea; (H.-J.K.); (B.J.)
| | - Beomseok Jeon
- Department of Neurology, Seoul National University Hospital, Seoul 03080, Korea; (H.-J.K.); (B.J.)
| | - Sun Ha Paek
- Department of Neurosurgery, Seoul National University Hospital, Seoul 03080, Korea; (Y.H.L.); (E.J.S.)
- Correspondence: ; Tel.: +82-22-072-2876
| |
Collapse
|
6
|
Wang J, Ponce FA, Tao J, Yu HM, Liu JY, Wang YJ, Luan GM, Ou SW. Comparison of Awake and Asleep Deep Brain Stimulation for Parkinson's Disease: A Detailed Analysis Through Literature Review. Neuromodulation 2019; 23:444-450. [PMID: 31830772 DOI: 10.1111/ner.13061] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 08/22/2019] [Accepted: 09/11/2019] [Indexed: 01/26/2023]
Abstract
OBJECTIVES Deep brain stimulation (DBS) for Parkinson's disease (PD) has been applied to clinic for approximately 30 years. The goal of this review is to explore the similarities and differences between "awake" and "asleep" DBS techniques. METHODS A comprehensive literature review was carried out to identify relevant studies and review articles describing applications of "awake" or "asleep" DBS for Parkinson's disease. The surgical procedures, clinical outcomes, costs and complications of each technique were compared in detail through literature review. RESULTS The surgical procedures of awake and asleep DBS surgeries rely upon different methods for verification of intended target acquisition. The existing research results demonstrated that the stereotactic targeting accuracy of lead placement obtained by either method is reliable. There were no significant differences in clinical outcomes, costs, or complications between the two techniques. CONCLUSION The surgical and clinical outcomes of asleep DBS for PD are comparable to those of awake DBS.
Collapse
Affiliation(s)
- Jun Wang
- Department of Neurosurgery, The First Hospital of China Medical University, Shenyang, P. R., China
| | - Francisco A Ponce
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
| | - Jun Tao
- Department of Neurosurgery, The First Hospital of China Medical University, Shenyang, P. R., China
| | - Hong-Mei Yu
- Department of Neurology, The First Hospital of China Medical University, Shenyang, P. R., China
| | - Ji-Yuan Liu
- Department of Neurosurgery, The First Hospital of China Medical University, Shenyang, P. R., China
| | - Yun-Jie Wang
- Department of Neurosurgery, The First Hospital of China Medical University, Shenyang, P. R., China
| | - Guo-Ming Luan
- Department of Neurosurgery, Beijing Sanbo Brain Hospital, Capital Medical University, Beijing, P. R., China
| | - Shao-Wu Ou
- Department of Neurosurgery, The First Hospital of China Medical University, Shenyang, P. R., China
| |
Collapse
|
7
|
Kremer NI, Oterdoom DLM, van Laar PJ, Piña-Fuentes D, van Laar T, Drost G, van Hulzen ALJ, van Dijk JMC. Accuracy of Intraoperative Computed Tomography in Deep Brain Stimulation-A Prospective Noninferiority Study. Neuromodulation 2019; 22:472-477. [PMID: 30629330 PMCID: PMC6618091 DOI: 10.1111/ner.12918] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2018] [Revised: 11/04/2018] [Accepted: 11/30/2018] [Indexed: 01/09/2023]
Abstract
Introduction Clinical response to deep brain stimulation (DBS) strongly depends on the appropriate placement of the electrode in the targeted structure. Postoperative MRI is recognized as the gold standard to verify the DBS‐electrode position in relation to the intended anatomical target. However, intraoperative computed tomography (iCT) might be a feasible alternative to MRI. Materials and Methods In this prospective noninferiority study, we compared iCT with postoperative MRI (24‐72 hours after surgery) in 29 consecutive patients undergoing placement of 58 DBS electrodes. The primary outcome was defined as the difference in Euclidean distance between lead tip coordinates as determined on both imaging modalities, using the lead tip depicted on MRI as reference. Secondary outcomes were difference in radial error and depth, as well as difference in accuracy relative to target. Results The mean difference between the lead tips was 0.98 ± 0.49 mm (0.97 ± 0.47 mm for the left‐sided electrodes and 1.00 ± 0.53 mm for the right‐sided electrodes). The upper confidence interval (95% CI, 0.851 to 1.112) did not exceed the noninferiority margin established. The average radial error between lead tips was 0.74 ± 0.48 mm and the average depth error was determined to be 0.53 ± 0.40 mm. The linear Deming regression indicated a good agreement between both imaging modalities regarding accuracy relative to target. Conclusions Intraoperative CT is noninferior to MRI for the verification of the DBS‐electrode position. CT and MRI have their specific benefits, but both should be considered equally suitable for assessing accuracy.
Collapse
Affiliation(s)
- Naomi I Kremer
- Department of Neurosurgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - D L Marinus Oterdoom
- Department of Neurosurgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Peter Jan van Laar
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Dan Piña-Fuentes
- Department of Neurosurgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Teus van Laar
- Department of Neurology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Gea Drost
- Department of Neurosurgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.,Department of Neurology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Arjen L J van Hulzen
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - J Marc C van Dijk
- Department of Neurosurgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
8
|
Engelhardt J, Guehl D, Damon-Perrière N, Branchard O, Burbaud P, Cuny E. Localization of Deep Brain Stimulation Electrode by Image Registration Is Software Dependent: A Comparative Study between Four Widely Used Software Programs. Stereotact Funct Neurosurg 2018; 96:364-369. [PMID: 30566953 DOI: 10.1159/000494982] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 10/24/2018] [Indexed: 11/19/2022]
Abstract
BACKGROUND The control of the anatomic position of the active contacts is essential to understand the effects and adapt the settings of the neurostimulation. The localization is commonly assessed by a registration between the preoperative MRI and the postoperative CT scan. However, its accuracy depends on the quality of the registration algorithm and many software programs are available. OBJECTIVE To compare the localization of implanted deep brain stimulation (DBS) leads in the subthalamic nucleus (STN) between four registration devices. METHODS The preoperative stereotactic MRI was co-registered and fused with the 3-month postoperative CT scan in 27 patients implanted in the STN for Parkinson's disease (53 leads). Localizations of the active contacts were calculated in the stereotactic frame space and compared between software programs. RESULTS The coordinates of the active contacts were different between software programs in the 3 axes (p < 0.001) with a mean vectorial error between the deepest contact locations of 1.17 mm (95% CI 1.09-1.25). CONCLUSION We found a small but significant difference in the coordinates calculated on four different devices. These results have to be considered when performing studies comparing active contact locations or when following patients with an implanted DBS lead.
Collapse
Affiliation(s)
- Julien Engelhardt
- CHU de Bordeaux, Service de neurochirurgie B, Bordeaux, France, .,Université de Bordeaux, Institut des maladies neurodégénératives, UMR 5293, Bordeaux, France,
| | - Dominique Guehl
- Université de Bordeaux, Institut des maladies neurodégénératives, UMR 5293, Bordeaux, France.,CHU de Bordeaux, Service d'explorations fonctionnelles du système nerveux, Bordeaux, France
| | - Nathalie Damon-Perrière
- Université de Bordeaux, Institut des maladies neurodégénératives, UMR 5293, Bordeaux, France.,CHU de Bordeaux, Service d'explorations fonctionnelles du système nerveux, Bordeaux, France
| | | | - Pierre Burbaud
- Université de Bordeaux, Institut des maladies neurodégénératives, UMR 5293, Bordeaux, France.,CHU de Bordeaux, Service d'explorations fonctionnelles du système nerveux, Bordeaux, France
| | - Emmanuel Cuny
- CHU de Bordeaux, Service de neurochirurgie B, Bordeaux, France.,Université de Bordeaux, Institut des maladies neurodégénératives, UMR 5293, Bordeaux, France
| |
Collapse
|
9
|
van der Loo LE, Schijns OEMG, Hoogland G, Colon AJ, Wagner GL, Dings JTA, Kubben PL. Methodology, outcome, safety and in vivo accuracy in traditional frame-based stereoelectroencephalography. Acta Neurochir (Wien) 2017; 159:1733-1746. [PMID: 28676892 PMCID: PMC5557874 DOI: 10.1007/s00701-017-3242-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Accepted: 05/31/2017] [Indexed: 11/24/2022]
Abstract
Background Stereoelectroencephalography (SEEG) is an established diagnostic technique for the localization of the epileptogenic zone in drug-resistant epilepsy. In vivo accuracy of SEEG electrode positioning is of paramount importance since higher accuracy may lead to more precise resective surgery, better seizure outcome and reduction of complications. Objective To describe experiences with the SEEG technique in our comprehensive epilepsy center, to illustrate surgical methodology, to evaluate in vivo application accuracy and to consider the diagnostic yield of SEEG implantations. Methods All patients who underwent SEEG implantations between September 2008 and April 2016 were analyzed. Planned electrode trajectories were compared with post-implantation trajectories after fusion of pre- and postoperative imaging. Quantitative analysis of deviation using Euclidean distance and directional errors was performed. Explanatory variables for electrode accuracy were analyzed using linear regression modeling. The surgical methodology, procedure-related complications and diagnostic yield were reported. Results Seventy-six implantations were performed in 71 patients, and a total of 902 electrodes were implanted. Median entry and target point deviations were 1.54 mm and 2.93 mm. Several factors that predicted entry and target point accuracy were identified. The rate of major complications was 2.6%. SEEG led to surgical therapy of various modalities in 53 patients (69.7%). Conclusions This study demonstrated that entry and target point localization errors can be predicted by linear regression models, which can aid in identification of high-risk electrode trajectories and further enhancement of accuracy. SEEG is a reliable technique, as demonstrated by the high accuracy of conventional frame-based implantation methodology and the good diagnostic yield.
Collapse
|
10
|
Gilmore G, Lee DH, Parrent A, Jog M. The current state of postoperative imaging in the presence of deep brain stimulation electrodes. Mov Disord 2017; 32:833-838. [DOI: 10.1002/mds.27028] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Revised: 03/01/2017] [Accepted: 03/31/2017] [Indexed: 11/08/2022] Open
Affiliation(s)
- Greydon Gilmore
- Department of Biomedical Engineering; Western University; London Canada
- Department of Clinical Neurological Sciences; University Hospital; London Canada
| | - Donald H. Lee
- Department of Medical Imaging; University Hospital; London Canada
| | - Andrew Parrent
- Department of Clinical Neurological Sciences; University Hospital; London Canada
- Department of Neurosurgery; University Hospital; London Canada
| | - Mandar Jog
- Department of Biomedical Engineering; Western University; London Canada
- Department of Clinical Neurological Sciences; University Hospital; London Canada
| |
Collapse
|
11
|
Li Z, Zhang JG, Ye Y, Li X. Review on Factors Affecting Targeting Accuracy of Deep Brain Stimulation Electrode Implantation between 2001 and 2015. Stereotact Funct Neurosurg 2016; 94:351-362. [PMID: 27784015 DOI: 10.1159/000449206] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Accepted: 08/16/2016] [Indexed: 11/19/2022]
Abstract
BACKGROUND Accurate implantation of a depth electrode into the brain is of the greatest importance in deep brain stimulation (DBS), and various stereotactic systems have been developed for electrode implantation. However, an updated analysis of depth electrode implantation in the modern era of DBS is lacking. OBJECTIVE This study aims at providing an updated review on targeting accuracy of DBS electrode implantation by analyzing contemporary DBS electrode implantation operations from the perspective of precision engineering. METHODS Eligible articles with information on targeting accuracy of DBS electrode implantation were searched in the PubMed database. RESULTS An average targeting error of DBS electrode implantation is reported to decrease toward 1 mm; the standard deviation of targeting error is decreasing toward 0.5 mm. Targeting accuracy is not only found to be affected by individual surgical steps, but also systematically affected by the architecture of the implantation operation. CONCLUSION A systematic strategy should be adopted to further improve the targeting accuracy of depth electrode implantation. Attention should be paid to optimizing the whole electrode implantation operation, which can help minimize error accumulation or amplification throughout the serially connected procedures for DBS electrode implantation.
Collapse
Affiliation(s)
- Zhe Li
- Department of Biomedical Engineering, National University of Singapore, Singapore, Singapore
| | | | | | | |
Collapse
|
12
|
Application of Preoperative CT/MRI Image Fusion in Target Positioning for Deep Brain Stimulation. ACTA ACUST UNITED AC 2016; 31:161-167. [PMID: 27733223 DOI: 10.1016/s1001-9294(16)30045-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
<strong>Objective</strong> To explore the efficacy of target positioning by preoperative CT/MRI image fusion technique in deep brain stimulation.<strong>Methods</strong> We retrospectively analyzed the clinical data and images of 79 cases (68 with Parkinson's disease, 11 with dystonia) who received preoperative CT/MRI image fusion in target positioning of subthalamic nucleus in deep brain stimulation. Deviation of implanted electrodes from the target nucleus of each patient were measured. Neurological evaluations of each patient before and after the treatment were performed and compared. Complications of the positioning and treatment were recorded.<strong>Results</strong> The mean deviations of the electrodes implanted on X, Y, and Z axis were 0.5 mm, 0.6 mm, and 0.6 mm, respectively. Postoperative neurologic evaluations scores of unified Parkinson's disease rating scale (UPDRS) for Parkinson's disease and Burke-Fahn-Marsden Dystonia Rating Scale (BFMDRS) for dystonia patients improved significantly compared to the preoperative scores (P<0.001); Complications occurred in 10.1% (8/79) patients, and main side effects were dysarthria and diplopia.<strong>Conclusion</strong> Target positioning by preoperative CT/MRI image fusion technique in deep brain stimulation has high accuracy and good clinical outcomes.
Collapse
|
13
|
Argiti K, Joseph K, Mottaghi S, Feuerstein TJ, Hofmann UG. Deep brain stimulation: increasing efficiency by alternative waveforms. CURRENT DIRECTIONS IN BIOMEDICAL ENGINEERING 2016. [DOI: 10.1515/cdbme-2016-0034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
AbstractDeep brain stimulation (DBS) is based on the effect of high frequency stimulation (HFS) in neuronal tissue. As a therapy option for patients suffering from e.g. Parkinson’s disease, DBS has been used for decades. Despite the widespread use, the effect of HFS on neurons is not fully investigated. Improving the stimulation efficiency und specificity could increase the efficiency of the INS (internal neuronal stimulator) as well as potentially reduce unwanted side effects. The effect of HFS on the GABAergic system was quantified using whole cell patch clamp electrophysiology during HFS stimulation in cortical human brain slices in vitro. Rectangular, sine, sawtooth and triangular waveforms were applied extracellularly. Since HFS has been hypothesized to increase the activity of the axons of GABAergic interneurons, a decrease in activity can be observed in the pyramidal cells that the interneurons project to. By isolating the incoming non- GABAergic events, we can filter out only the GABAA currents which can be verified using a GABAA antagonist. The results show that all the waveforms effectively increase the GABAA currents. The triangle waveform causes the highest significant increase in the activity which further increases over time after the stimulation was turned off.
Collapse
Affiliation(s)
- Katerina Argiti
- 1Section Clin. Neuropharmacology, Medical Center University of Freiburg, Freiburg, Germany
| | - Kevin Joseph
- 2Section Clin. Neuropharmacology and Section Neuroelectronics Systems, Medical Center University of Freiburg, Freiburg, Germany
| | - Soheil Mottaghi
- 3Section Neuroelectronics Systems, Medical Center University of Freiburg, Freiburg, Germany
| | - Thomas J. Feuerstein
- 1Section Clin. Neuropharmacology, Medical Center University of Freiburg, Freiburg, Germany
| | - Ulrich G. Hofmann
- 3Section Neuroelectronics Systems, Medical Center University of Freiburg, Freiburg, Germany
- 4Cluster of Excellence BrainLinks-BrainTools, University of Freiburg, Germany
| |
Collapse
|
14
|
Sammartino F, Krishna V, King NKK, Bruno V, Kalia S, Hodaie M, Marras C, Lozano AM, Fasano A. Sequence of electrode implantation and outcome of deep brain stimulation for Parkinson's disease. J Neurol Neurosurg Psychiatry 2016; 87:859-63. [PMID: 26354942 DOI: 10.1136/jnnp-2015-311426] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Accepted: 08/17/2015] [Indexed: 11/03/2022]
Abstract
INTRODUCTION The effect of the variability of electrode placement on outcomes after bilateral deep brain stimulation of subthalamic nucleus has not been sufficiently studied, especially with respect to the sequence of hemisphere implantation. METHODOLOGY We retrospectively analysed the clinical and radiographic data of all the consecutive patients with Parkinson's disease who underwent surgery at our centre and completed at least 1 year follow-up. The dispersion in electrode location was calculated by the square of deviation from population mean, and the direction of deviation was analysed by comparing the intended and final implantation coordinates. Linear regression analysis was performed to analyse the predictors of postoperative improvement of the motor condition, also controlling for the sequence of implanted hemisphere. RESULTS 76 patients (mean age 58±7.2 years) were studied. Compared with the first side, the second side electrode tip had significantly higher dispersion as an overall effect (5.6±21.6 vs 2.2±4.9 mm(2), p=0.04), or along the X-axis (4.1±15.6 vs 1.4±2.4 mm(2), p=0.03) and Z-axis (4.9±11.5 vs 2.9±3.6 mm(2), p=0.02); the second side stimulation was also associated with a lower threshold for side effects (contact 0, p<0.001 and contact 3, p=0.004). In the linear regression analysis, the significant predictors of outcome were baseline activities of daily living (p=0.010) and dispersion of electrode on the second side (p=0.005). CONCLUSIONS We observed a higher dispersion for the electrode on the second implanted side, which also resulted to be a significant predictor of motor outcome at 1 year.
Collapse
Affiliation(s)
- Francesco Sammartino
- Division of Neurosurgery, University of Toronto, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Vibhor Krishna
- Division of Neurosurgery, University of Toronto, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Nicolas Kon Kam King
- Division of Neurosurgery, University of Toronto, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Veronica Bruno
- Morton and Gloria Shulman Movement Disorders Clinic and the Edmond J. Safra Program in Parkinson's Disease, Toronto Western Hospital - UHN, Division of Neurology, University of Toronto, Toronto, Ontario, Canada
| | - Suneil Kalia
- Division of Neurosurgery, University of Toronto, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Mojgan Hodaie
- Division of Neurosurgery, University of Toronto, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Connie Marras
- Morton and Gloria Shulman Movement Disorders Clinic and the Edmond J. Safra Program in Parkinson's Disease, Toronto Western Hospital - UHN, Division of Neurology, University of Toronto, Toronto, Ontario, Canada
| | - Andres M Lozano
- Division of Neurosurgery, University of Toronto, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Alfonso Fasano
- Morton and Gloria Shulman Movement Disorders Clinic and the Edmond J. Safra Program in Parkinson's Disease, Toronto Western Hospital - UHN, Division of Neurology, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
15
|
Saleh C, Dooms G, Berthold C, Hertel F. Post-operative imaging in deep brain stimulation: A controversial issue. Neuroradiol J 2016; 29:244-9. [PMID: 27029393 PMCID: PMC4978322 DOI: 10.1177/1971400916639960] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
In deep brain stimulation (DBS), post-operative imaging has been used on the one hand to assess complications, such as haemorrhage; and on the other hand, to detect misplaced contacts. The post-operative determination of the accurate location of the final electrode plays a critical role in evaluating the precise area of effective stimulation and for predicting the potential clinical outcome; however, safety remains a priority in postoperative DBS imaging. A plethora of diverse post-operative imaging methods have been applied at different centres. There is neither a consensus on the most efficient post-operative imaging methodology, nor is there any standardisation for the automatic or manual analysis of the images within the different imaging modalities. In this article, we give an overview of currently applied post-operative imaging modalities and discuss the current challenges in post-operative imaging in DBS.
Collapse
Affiliation(s)
- Christian Saleh
- Department of Neurology, Centre Hospitalier de Luxembourg, Luxembourg
| | - Georges Dooms
- Department of Neuroradiology, Centre Hospitalier de Luxembourg, Luxembourg
| | | | - Frank Hertel
- Department of Neurosurgery, Centre Hospitalier de Luxembourg, Luxembourg
| |
Collapse
|
16
|
Geevarghese R, O''Gorman Tuura R, Lumsden DE, Samuel M, Ashkan K. Registration Accuracy of CT/MRI Fusion for Localisation of Deep Brain Stimulation Electrode Position: An Imaging Study and Systematic Review. Stereotact Funct Neurosurg 2016; 94:159-63. [DOI: 10.1159/000446609] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Accepted: 05/04/2016] [Indexed: 11/19/2022]
|
17
|
Barnaure I, Pollak P, Momjian S, Horvath J, Lovblad KO, Boëx C, Remuinan J, Burkhard P, Vargas MI. Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT). Neuroradiology 2015; 57:903-8. [PMID: 26022355 DOI: 10.1007/s00234-015-1547-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2015] [Accepted: 05/21/2015] [Indexed: 10/23/2022]
Abstract
INTRODUCTION Imaging has an essential role in the evaluation of correct positioning of electrodes implanted for deep brain stimulation (DBS). Although MRI offers superior anatomic visualization of target sites, there are safety concerns in patients with implanted material; imaging guidelines are inconsistent and vary. The fusion of postoperative CT with preoperative MRI images can be an alternative for the assessment of electrode positioning. The purpose of this study was to assess the accuracy of measurements realized on fused images (acquired without a stereotactic frame) using a manufacturer-provided software. METHODS Data from 23 Parkinson's disease patients who underwent bilateral electrode placement for subthalamic nucleus (STN) DBS were acquired. Preoperative high-resolution T2-weighted sequences at 3 T, and postoperative CT series were fused using a commercially available software. Electrode tip position was measured on the obtained images in three directions (in relation to the midline, the AC-PC line and an AC-PC line orthogonal, respectively) and assessed in relation to measures realized on postoperative 3D T1 images acquired at 1.5 T. RESULTS Mean differences between measures carried out on fused images and on postoperative MRI lay between 0.17 and 0.97 mm. CONCLUSION Fusion of CT and MRI images provides a safe and fast technique for postoperative assessment of electrode position in DBS.
Collapse
Affiliation(s)
- I Barnaure
- Department of Neuroradiology, Geneva University Hospital, Gabrielle Perret Gentil, 4, 1211, Geneva 14, Switzerland
| | - P Pollak
- Department of Neurology, Geneva University Hospital, Geneva, Switzerland
| | - S Momjian
- Department of Neurosurgery, Geneva University Hospital, Geneva, Switzerland
| | - J Horvath
- Department of Neurology, Geneva University Hospital, Geneva, Switzerland
| | - K O Lovblad
- Department of Neuroradiology, Geneva University Hospital, Gabrielle Perret Gentil, 4, 1211, Geneva 14, Switzerland
| | - C Boëx
- Department of Neurology, Geneva University Hospital, Geneva, Switzerland
| | - J Remuinan
- Department of Radiology, Geneva University Hospital, Geneva, Switzerland
| | - P Burkhard
- Department of Neurology, Geneva University Hospital, Geneva, Switzerland
| | - M I Vargas
- Department of Neuroradiology, Geneva University Hospital, Gabrielle Perret Gentil, 4, 1211, Geneva 14, Switzerland.
| |
Collapse
|
18
|
Surgery for treatment of refractory chronic cluster headache: toward standard procedures. Neurol Sci 2015; 36 Suppl 1:131-5. [PMID: 26017528 DOI: 10.1007/s10072-015-2179-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The degree of disability due to chronic cluster headache refractory to conservative treatments justifies surgical procedures as second-line treatments. Many studies and reports nowadays confirm the efficacy of the two mostly used surgical techniques in such cases. Both deep brain stimulation and occipital nerve stimulation are in fact currently utilized for this purpose but the surgical technique has not yet been standardized. We describe the surgical steps of both procedures.
Collapse
|
19
|
Intraoperative CT verification of electrode localization in DBS surgery in Parkinson's disease. INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT 2015. [DOI: 10.1016/j.inat.2014.10.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
20
|
Wang Y, Liu T. Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker. Magn Reson Med 2015; 73:82-101. [PMID: 25044035 PMCID: PMC4297605 DOI: 10.1002/mrm.25358] [Citation(s) in RCA: 550] [Impact Index Per Article: 61.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2014] [Revised: 06/13/2014] [Accepted: 06/18/2014] [Indexed: 01/03/2023]
Abstract
In MRI, the main magnetic field polarizes the electron cloud of a molecule, generating a chemical shift for observer protons within the molecule and a magnetic susceptibility inhomogeneity field for observer protons outside the molecule. The number of water protons surrounding a molecule for detecting its magnetic susceptibility is vastly greater than the number of protons within the molecule for detecting its chemical shift. However, the study of tissue magnetic susceptibility has been hindered by poor molecular specificities of hitherto used methods based on MRI signal phase and T2* contrast, which depend convolutedly on surrounding susceptibility sources. Deconvolution of the MRI signal phase can determine tissue susceptibility but is challenged by the lack of MRI signal in the background and by the zeroes in the dipole kernel. Recently, physically meaningful regularizations, including the Bayesian approach, have been developed to enable accurate quantitative susceptibility mapping (QSM) for studying iron distribution, metabolic oxygen consumption, blood degradation, calcification, demyelination, and other pathophysiological susceptibility changes, as well as contrast agent biodistribution in MRI. This paper attempts to summarize the basic physical concepts and essential algorithmic steps in QSM, to describe clinical and technical issues under active development, and to provide references, codes, and testing data for readers interested in QSM.
Collapse
Affiliation(s)
- Yi Wang
- Radiology, Weill Medical College of Cornell UniversityNew York, New York, USA
- Biomedical Engineering, Cornell UniversityIthaca, New York, USA
- Biomedical Engineering, Kyung Hee UniversitySeoul, South Korea
| | - Tian Liu
- MedImageMetric, LLCNew York, New York, USA
| |
Collapse
|
21
|
Cardinale F, Cossu M, Castana L, Casaceli G, Schiariti MP, Miserocchi A, Fuschillo D, Moscato A, Caborni C, Arnulfo G, Lo Russo G. Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. Neurosurgery 2013; 72:353-66; discussion 366. [PMID: 23168681 DOI: 10.1227/neu.0b013e31827d1161] [Citation(s) in RCA: 368] [Impact Index Per Article: 33.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND Stereoelectroencephalography (SEEG) methodology, originally developed by Talairach and Bancaud, is progressively gaining popularity for the presurgical invasive evaluation of drug-resistant epilepsies. OBJECTIVE To describe recent SEEG methodological implementations carried out in our center, to evaluate safety, and to analyze in vivo application accuracy in a consecutive series of 500 procedures with a total of 6496 implanted electrodes. METHODS Four hundred nineteen procedures were performed with the traditional 2-step surgical workflow, which was modified for the subsequent 81 procedures. The new workflow entailed acquisition of brain 3-dimensional angiography and magnetic resonance imaging in frameless and markerless conditions, advanced multimodal planning, and robot-assisted implantation. Quantitative analysis for in vivo entry point and target point localization error was performed on a sub--data set of 118 procedures (1567 electrodes). RESULTS The methodology allowed successful implantation in all cases. Major complication rate was 12 of 500 (2.4%), including 1 death for indirect morbidity. Median entry point localization error was 1.43 mm (interquartile range, 0.91-2.21 mm) with the traditional workflow and 0.78 mm (interquartile range, 0.49-1.08 mm) with the new one (P < 2.2 × 10). Median target point localization errors were 2.69 mm (interquartile range, 1.89-3.67 mm) and 1.77 mm (interquartile range, 1.25-2.51 mm; P < 2.2 × 10), respectively. CONCLUSION SEEG is a safe and accurate procedure for the invasive assessment of the epileptogenic zone. Traditional Talairach methodology, implemented by multimodal planning and robot-assisted surgery, allows direct electrical recording from superficial and deep-seated brain structures, providing essential information in the most complex cases of drug-resistant epilepsy.
Collapse
Affiliation(s)
- Francesco Cardinale
- Claudio Munari Centre for Epilepsy and Parkinson Surgery, Niguarda Ca' Granda Hospital, Milano, Italy.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Thani NB, Bala A, Swann GB, Lind CRP. Accuracy of postoperative computed tomography and magnetic resonance image fusion for assessing deep brain stimulation electrodes. Neurosurgery 2013; 69:207-14; discussion 214. [PMID: 21792120 DOI: 10.1227/neu.0b013e318218c7ae] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Knowledge of the anatomic location of the deep brain stimulation (DBS) electrode in the brain is essential in quality control and judicious selection of stimulation parameters. Postoperative computed tomography (CT) imaging coregistered with preoperative magnetic resonance imaging (MRI) is commonly used to document the electrode location safely. The accuracy of this method, however, depends on many factors, including the quality of the source images, the area of signal artifact created by the DBS lead, and the fusion algorithm. OBJECTIVE To calculate the accuracy of determining the location of active contacts of the DBS electrode by coregistering postoperative CT image to intraoperative MRI. METHODS Intraoperative MRI with a surrogate marker (carbothane stylette) was digitally coregistered with postoperative CT with DBS electrodes in 8 consecutive patients. The location of the active contact of the DBS electrode was calculated in the stereotactic frame space, and the discrepancy between the 2 images was assessed. RESULTS The carbothane stylette significantly reduces the signal void on the MRI to a mean diameter of 1.4 ± 0.1 mm. The discrepancy between the CT and MRI coregistration in assessing the active contact location of the DBS lead is 1.6 ± 0.2 mm, P < .001 with iPlan (BrainLab AG, Erlangen, Germany) and 1.5 ± 0.2 mm, P < .001 with Framelink (Medtronic, Minneapolis, Minnesota) software. CONCLUSION CT/MRI coregistration is an acceptable method of identifying the anatomic location of DBS electrode and active contacts.
Collapse
Affiliation(s)
- Nova B Thani
- West Australian Neurosurgical Service, Sir Charles Gairdner Hospital, Perth, Australia
| | | | | | | |
Collapse
|
23
|
Lumsden DE, Ashmore J, Charles-Edwards G, Lin JP, Ashkan K, Selway R. Accuracy of stimulating electrode placement in paediatric pallidal deep brain stimulation for primary and secondary dystonia. Acta Neurochir (Wien) 2013; 155:823-36. [PMID: 23430231 DOI: 10.1007/s00701-013-1629-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2012] [Accepted: 01/24/2013] [Indexed: 12/14/2022]
Abstract
BACKGROUND Accuracy of electrode placement is an important determinant of outcome following deep brain stimulation (DBS) surgery. Data on accuracy of electrode placement into the globus pallidum interna (GPi) in paediatric patients is limited, particularly those with non-primary dystonia who often have smaller GPi. Pallidal DBS is known to be more effective in the treatment of primary dystonia compared with secondary dystonia. OBJECTIVES We aimed to determine if accuracy of pallidal electrode placement differed between primary, secondary and NBIA (neuronal degeneration and brain iron accumulation) associated dystonia and how this related to motor outcome following surgery. METHODS A retrospective review of a consecutive cohort of children and young people undergoing DBS surgery in a single centre. Fused in frame preoperative planning magnetic resonance imaging (MRI) and postoperative computed tomography (CT) brain scans were used to determine the accuracy of placement of DBS electrode tip in Leskell stereotactic system compared with the planned target. The differences along X, Y, and Z coordinates were calculated, as was the Euclidean distance of electrode tip from the target. The relationship between proximity to target and change in Burke-Fahn-Marsden Dystonia Rating Scale at 1 year was also measured. RESULTS Data were collected from 88 electrodes placed in 42 patients (14 primary dystonia, 18 secondary dystonia and 10 NBIA associated dystonia). Median differences between planned target and actual position were: left-side X-axis 1.05 mm, Y-axis 0.85 mm, Z-axis 0.94 mm and Euclidean difference 2.04 mm; right-side X-axis 1.28 mm, Y-axis 0.70 mm, Z-axis 0.70 mm and Euclidean difference 2.45 mm. Accuracy did not differ between left and right-sided electrodes. No difference in accuracy was seen between primary, secondary or NBIA associated dystonia. Dystonia reduction at 1 year post surgery did not appear to relate to proximity of implanted electrode to surgical target across the cohort. CONCLUSIONS Accuracy of surgical placement did not differ between primary, secondary or NBIA associated dystonia. Decreased efficacy of pallidal DBS in secondary and NBIA associated dystonia is unlikely to be related to difficulties in achieving the planned electrode placement.
Collapse
Affiliation(s)
- Daniel E Lumsden
- Complex Motor Disorders Service, Evelina Children's Hospital, Guy's & St Thomas' NHS Foundation Trust, Lambeth Palace Road, London, SE1 7EH, UK.
| | | | | | | | | | | |
Collapse
|
24
|
Paek SH, Yun JY, Song SW, Kim IK, Hwang JH, Kim JW, Kim HJ, Kim HJ, Kim YE, Lim YH, Kim MR, Huh JH, Lee KM, Park SK, Kim C, Kim DG, Jeon BS. The clinical impact of precise electrode positioning in STN DBS on three-year outcomes. J Neurol Sci 2013; 327:25-31. [DOI: 10.1016/j.jns.2013.01.037] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2012] [Revised: 01/25/2013] [Accepted: 01/29/2013] [Indexed: 11/16/2022]
|
25
|
Holl EM, Petersen EA, Foltynie T, Martinez-Torres I, Limousin P, Hariz MI, Zrinzo L. Improving targeting in image-guided frame-based deep brain stimulation. Neurosurgery 2011; 67:437-47. [PMID: 21099570 DOI: 10.1227/neu.0b013e3181f7422a] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Deep brain stimulation (DBS) is commonly used in the treatment of movement disorders such as Parkinson disease (PD), dystonia, and other tremors. OBJECTIVE To examine systematic errors in image-guided DBS electrode placement and to explore a calibration strategy for stereotactic targeting. METHODS Pre- and postoperative stereotactic MR images were analyzed in 165 patients. The perpendicular error between planned target coordinates and electrode trajectory was calculated geometrically for all 312 DBS electrodes implanted. Improvement in motor unified PD rating scale III subscore was calculated for those patients with PD with at least 6 months of follow-up after bilateral subthalamic DBS. RESULTS Mean (standard deviation) scalar error of all electrodes was 1.4(0.9) mm with a significant difference between left and right hemispheres. Targeting error was significantly higher for electrodes with coronal approach angle (ARC) ≥10° (P < .001). Mean vector error was X: -0.6, Y: -0.7, and Z: -0.4 mm (medial, posterior, and superior directions, respectively). Targeting error was significantly improved by using a systematic calibration strategy based on ARC and target hemisphere (mean: 0.6 mm, P < .001) for 47 electrodes implanted in 24 patients. Retrospective theoretical calibration for all 312 electrodes would have reduced the mean (standard deviation) scalar error from 1.4(0.9) mm to 0.9(0.5) mm (36% improvement). With calibration, 97% of all electrodes would be within 2 mm of the intended target as opposed to 81% before calibration. There was no significant correlation between the degree of error and clinical outcome from bilateral subthalamic nucleus DBS (R = 0.07). CONCLUSION After calibration of a systematic targeting error an MR image-guided stereotactic approach would be expected to deliver 97% of all electrodes to within 2 mm of the intended target point with a single brain pass.
Collapse
Affiliation(s)
- Etienne M Holl
- Unit of Functional Neurosurgery, Sobell Department of Motor Neuroscience and Movement Disorders, UCL Institute of Neurology, University College London, London, United Kingdom
| | | | | | | | | | | | | |
Collapse
|
26
|
Paek SH, Lee JY, Kim HJ, Kang D, Lim YH, Kim MR, Kim C, Jeon BS, Kim DG. Electrode position and the clinical outcome after bilateral subthalamic nucleus stimulation. J Korean Med Sci 2011; 26:1344-55. [PMID: 22022189 PMCID: PMC3192348 DOI: 10.3346/jkms.2011.26.10.1344] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2011] [Accepted: 08/29/2011] [Indexed: 11/20/2022] Open
Abstract
We compared the surgical outcome with electrode positions after bilateral subthalamic nucleus (STN) stimulation surgery for Parkinson's disease. Fifty-seven patients treated with bilateral STN stimulations were included in this study. Electrode positions were determined in the fused images of preoperative MRI and postoperative CT taken at six months after surgery. The patients were divided into three groups: group I, both electrodes in the STN; group II, only one electrode in the STN; group III, neither electrode in the STN. Unified Parkinson's Disease Rating Scale (UPDRS), Hoehn and Yahr stage, and activities of daily living scores significantly improved at 6 and 12 months after STN stimulation in both group I and II. The off-time UPDRS III speech subscore significantly improved (1.6 ± 0.7 at baseline vs 1.3 ± 0.8 at 6 and 12 months, P < 0.01) with least L-dopa equivalent daily dose (LEDD) (844.6 ± 364.1 mg/day at baseline; 279.4 ± 274.6 mg/day at 6 months; and 276.0 ± 301.6 mg/day at 12 months, P < 0.001) at 6 and 12 months after STN deep brain stimulation (DBS) in the group I. Our findings suggest that the better symptom relief including speech with a reduced LEDD is expected in the patients whose electrodes are accurately positioned in both STN.
Collapse
Affiliation(s)
- Sun Ha Paek
- Movement Disorder Center and Clinical Research Institute, Seoul National University Hospital, Seoul, Korea
- Department of Neurosurgery, Seoul National University Hospital, Seoul, Korea
- Neuroscience Research Institute, Seoul National University College of Medicine, Seoul, Korea
- Ischemia Hypoxia Disease Institute, Seoul National University College of Medicine, Seoul, Korea
- Cancer Research Institute, Seoul National University College of Medicine, Seoul, Korea
| | - Jee-Young Lee
- Movement Disorder Center and Clinical Research Institute, Seoul National University Hospital, Seoul, Korea
- Department of Neurology, Seoul National University Hospital, Seoul, Korea
| | - Han-Joon Kim
- Movement Disorder Center and Clinical Research Institute, Seoul National University Hospital, Seoul, Korea
- Department of Neurology, Seoul National University Hospital, Seoul, Korea
| | - Daehee Kang
- Department of Preventive Medicine, Seoul National University College of Medicine, Seoul, Korea
| | - Yong Hoon Lim
- Movement Disorder Center and Clinical Research Institute, Seoul National University Hospital, Seoul, Korea
| | - Mi Ryoung Kim
- Movement Disorder Center and Clinical Research Institute, Seoul National University Hospital, Seoul, Korea
| | | | - Beom Seok Jeon
- Movement Disorder Center and Clinical Research Institute, Seoul National University Hospital, Seoul, Korea
- Department of Neurology, Seoul National University Hospital, Seoul, Korea
- Neuroscience Research Institute, Seoul National University College of Medicine, Seoul, Korea
| | - Dong Gyu Kim
- Movement Disorder Center and Clinical Research Institute, Seoul National University Hospital, Seoul, Korea
- Department of Neurosurgery, Seoul National University Hospital, Seoul, Korea
| |
Collapse
|
27
|
Yazdan-Shahmorad A, Lehmkuhle MJ, Gage GJ, Marzullo TC, Parikh H, Miriani RM, Kipke DR. Estimation of electrode location in a rat motor cortex by laminar analysis of electrophysiology and intracortical electrical stimulation. J Neural Eng 2011; 8:046018. [PMID: 21690656 DOI: 10.1088/1741-2560/8/4/046018] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
While the development of microelectrode arrays has enabled access to disparate regions of a cortex for neurorehabilitation, neuroprosthetic and basic neuroscience research, accurate interpretation of the signals and manipulation of the cortical neurons depend upon the anatomical placement of the electrode arrays in a layered cortex. Toward this end, this report compares two in vivo methods for identifying the placement of electrodes in a linear array spaced 100 µm apart based on in situ laminar analysis of (1) ketamine-xylazine-induced field potential oscillations in a rat motor cortex and (2) an intracortical electrical stimulation-induced movement threshold. The first method is based on finding the polarity reversal in laminar oscillations which is reported to appear at the transition between layers IV and V in laminar 'high voltage spindles' of the rat cortical column. Analysis of histological images in our dataset indicates that polarity reversal is detected 150.1 ± 104.2 µm below the start of layer V. The second method compares the intracortical microstimulation currents that elicit a physical movement for anodic versus cathodic stimulation. It is based on the hypothesis that neural elements perpendicular to the electrode surface are preferentially excited by anodic stimulation while cathodic stimulation excites those with a direction component parallel to its surface. With this method, we expect to see a change in the stimulation currents that elicits a movement at the beginning of layer V when comparing anodic versus cathodic stimulation as the upper cortical layers contain neuronal structures that are primarily parallel to the cortical surface and lower layers contain structures that are primarily perpendicular. Using this method, there was a 78.7 ± 68 µm offset in the estimate of the depth of the start of layer V. The polarity reversal method estimates the beginning of layer V within ±90 µm with 95% confidence and the intracortical stimulation method estimates it within ±69.3 µm. We propose that these methods can be used to estimate the in situ location of laminar electrodes implanted in the rat motor cortex.
Collapse
Affiliation(s)
- A Yazdan-Shahmorad
- Biomedical Engineering Department, University of Michigan, Ann Arbor, MI, USA.
| | | | | | | | | | | | | |
Collapse
|
28
|
Patil AA. Intraoperative image fusion to ascertain adequate lead placement. Stereotact Funct Neurosurg 2011; 89:197-200. [PMID: 21597308 DOI: 10.1159/000327030] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2010] [Accepted: 02/12/2011] [Indexed: 11/19/2022]
Abstract
BACKGROUND In order to view the position of the deep brain stimulator (DBS) lead in relation to the stereotactic target on 3-tesla magnetic resonance (3T-MR) images prior to the conclusion of the procedure, intraoperative postimplantation computed tomography (CT) images were fused with preoperative 3T-MR images. The method to do this is described and discussed in this paper. METHODS Over the last year, this method was used for 8 procedures: 6 for subthalamic nucleus and 2 for ventral-intermediate nucleus of the thalamus. The procedures were done on the CT table in a stereotactic frame. CT and MR images plus coordinates from the Schaltenbrand atlas were used to plan the target. After the lead had been placed at the target, intraoperative CT images were obtained and fused with preoperative 3T-MR images prior to the conclusion of the procedure. If error was detected in the lead position, it was corrected. RESULTS Errors in the x-coordinate were detected in 2 patients. These errors were corrected prior to the conclusion of the procedures. CONCLUSION This is a simple method to intraoperatively visualize DBS lead position on high-quality 3T-MR images. It gives the surgeon the capability to detect errors and correct them prior to the conclusion of the procedure.
Collapse
|
29
|
Chang WS, Kim HY, Kim JP, Park YS, Chung SS, Chang JW. Bilateral subthalamic deep brain stimulation using single track microelectrode recording. Acta Neurochir (Wien) 2011; 153:1087-95. [PMID: 21311918 DOI: 10.1007/s00701-011-0953-1] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2010] [Accepted: 01/19/2011] [Indexed: 12/14/2022]
Abstract
BACKGROUND Microelectrode recording (MER) is widely used during deep brain stimulation (DBS) procedures because MER can identify structural borders and eloquent structures, localize somatotopic arrangements, and provide an outline of the three-dimensional shapes of target nuclei. However, MER may cause intracranial hemorrhage. We preformed single track MER during DBS procedures, analyzed the accuracy of electrode positioning with MRI, and compared the amount of air and the potential risk of intracranial hemorrhage. METHOD A total of 46 electrodes were placed in 23 patients who suffered from advanced Parkinson's disease and who underwent bilateral subthalamic nucleus DBS using single track MER. Each patient's Unified Parkinson's Disease Rating Scale (UPDRS) score and levo-dopa equivalent dosage (LED) were estimated pre- and postoperatively. The accuracy of electrode positioning and fontal air thickness was measured by a pre- or postoperative magnetic resonance imaging (MRI) merging technique. FINDINGS The mean electrode positioning error was 0.92 mm (0.3-2.94 mm). The mean frontal air thickness on postoperative MRI was 3.85 mm (0-10.3 mm), which did not affect the electrode accuracy statistically (p = 0.730). A total of nine electrodes required repositioning after single-track MER because they affected microstimulation or because an abnormally short STN length was observed during MER. In this series, one patient suffered from an intracranial hemorrhage after surgery that appeared to be due to venous infarction rather than related to MER. CONCLUSIONS Although MER can facilitate accurate positioning of electrodes, multi-track MER may increase the risk of intracranial hemorrhage. The accuracy of electrode positioning appears to be acceptable under single track MER during STN DBS with careful electrophysiological and neurological monitoring. The risk of intracranial hemorrhage appears to be minimal, especially in elderly patients with atrophic brains.
Collapse
Affiliation(s)
- Won Seok Chang
- Department of Neurosurgery, Yonsei University College of Medicine, 205 Seongsanno Seodaemun-gu, Seoul, 120-752, Korea
| | | | | | | | | | | |
Collapse
|
30
|
Shamir RR, Joskowicz L, Spektor S, Shoshan Y. Target and Trajectory Clinical Application Accuracy in Neuronavigation. Oper Neurosurg (Hagerstown) 2011; 68:95-101; discussion 101-2. [DOI: 10.1227/neu.0b013e31820828d9] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Abstract
BACKGROUND:
Catheter, needle, and electrode misplacement in navigated neurosurgery can result in ineffective treatment and severe complications.
OBJECTIVE:
To assess the Ommaya ventricular catheter localization accuracy both along the planned trajectory and at the target.
METHODS:
We measured the localization error along the ventricular catheter and on its tip for 15 consecutive patients who underwent insertion of the Ommaya catheter surgery with a commercial neuronavigation system. The preoperative computed tomography/magnetic resonance images and the planned trajectory were aligned with the postoperative computed tomography images showing the Ommaya catheter. The localization errors along the trajectory and at the target were then computed by comparing the preoperative planned trajectory with the actual postoperative catheter position. The measured localization errors were also compared with the error reported by the navigation system.
RESULTS:
The mean localization errors at the target and entry point locations were 5.9 ± 4.3 and 3.3 ± 1.9 mm, respectively. The mean shift and angle between planned and actual trajectories were 1.6 ± 1.9 mm and 3.9 ± 4.7°, respectively. The mean difference between the localization error at the target and entry point was 3.9 ± 3.7 mm. The mean difference between the target localization error and the reported navigation system error was 4.9 ± 4.8 mm.
CONCLUSION:
The catheter localization errors have significant variations at the target and along the insertion trajectory. Trajectory errors may differ significantly from the errors at the target. Moreover, the single registration error number reported by the navigation system does not appropriately reflect the trajectory and target errors and thus should be used with caution to assess the procedure risk.
Collapse
Affiliation(s)
- Reuben R Shamir
- School of Engineering and Computer Science, The Hebrew University, Jerusalem, Israel
| | - Leo Joskowicz
- School of Engineering and Computer Science, The Hebrew University, Jerusalem, Israel
| | - Sergey Spektor
- Department of Neurosurgery, The Hebrew University Hadassah Medical Center, Jerusalem, Israel
| | - Yigal Shoshan
- Department of Neurosurgery, The Hebrew University Hadassah Medical Center, Jerusalem, Israel
| |
Collapse
|
31
|
Franzini A, Messina G, Cordella R, Marras C, Broggi G. Deep brain stimulation of the posteromedial hypothalamus: indications, long-term results, and neurophysiological considerations. Neurosurg Focus 2010; 29:E13. [PMID: 20672915 DOI: 10.3171/2010.5.focus1094] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT The aim of this study was to review the indications for and results of deep brain stimulation (DBS) of the posterior hypothalamus (pHyp) in the treatment of drug-refractory and severe painful syndromes of the face, disruptive and aggressive behavior associated with epilepsy, and below-average intelligence. The preoperative clinical picture, functional imaging studies, and overall clinical results in the literature are discussed. METHODS All patients underwent stereotactic implantation of deep-brain electrodes within the pHyp. Data from several authors have been collected and reported for each clinical entity, as have clinical results, adverse events, and neurophysiological characteristics of the pHyp. RESULTS The percentage of patients with chronic cluster headache who responded to DBS was 50% in the overall reported series. The response rate was 100% for short-lasting unilateral neuralgiform headache attacks with conjunctival injection and tearing and for chronic paroxysmal hemicrania, although only 2 patients and 1 patient, respectively, have been described as having these conditions. None of the 4 patients suffering from refractory neuropathic trigeminal pain benefited from the procedure (0% response rate), whereas all 5 patients (100%) affected with refractory trigeminal neuralgia (TN) due to multiple sclerosis (MS) and undergoing pHyp DBS experienced a significant decrease in pain attacks within the first branch of cranial nerve V. Six (75%) of 8 patients presenting with aggressive behavior and mental retardation benefited from pHyp stimulation; 6 patients were part of the authors' series and 2 were reported in the literature. CONCLUSIONS In carefully selected patients, DBS of the pHyp can be considered an effective procedure for the treatment of refractory trigeminal autonomic cephalalgias, aggressive behavior, and MS-related TN in the first trigeminal branch. Only larger and prospective studies along with multidisciplinary approaches (including, by necessity, neuroimaging studies) can lead us to better patient selection that would reduce the rate of nonresponders.
Collapse
Affiliation(s)
- Angelo Franzini
- Department of Neurosurgery, Fondazione IRCCS Istituto Nazionale Neurologico Carlo Besta, Milan, Italy.
| | | | | | | | | |
Collapse
|
32
|
Shin M, Penholate MF, Lefaucheur JP, Gurruchaga JM, Brugieres P, Nguyen JP. Assessing Accuracy of the Magnetic Resonance Imaging-Computed Tomography Fusion Images to Evaluate the Electrode Positions in Subthalamic Nucleus After Deep-Brain Stimulation. Neurosurgery 2010; 66:1193-202; discussion 1202. [DOI: 10.1227/01.neu.0000369190.46510.42] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Masahiro Shin
- Service de Neurochirurgie, Hôpital Henri Mondor, Assistance Publique-Hôpitaux de Paris, Créteil, France, and Department of Neurosurgery, Tokyo Metropolitan Neurological Hospital, Tokyo, Japan
| | - Marcello Faria Penholate
- Service de Neurochirurgie, Hôpital Henri Mondor, Assistance Publique-Hôpitaux de Paris, Créteil, France
| | - Jean-Pascal Lefaucheur
- Service de Physiologie-Explorations Fonctionnelles, Hôpital Henri Mondor, Assistance Publique-Hôpitaux de Paris, Créteil, France
| | - Jean-Marc Gurruchaga
- Service de Neurochirurgie, Service de Neurologie, Hôpital Henri Mondor, Assistance Publique-Hôpitaux de Paris, Créteil, France
| | - Pierre Brugieres
- Service de Neuroradiologie, Hôpital Henri Mondor, Assistance Publique-Hôpitaux de Paris, Créteil, France
| | - Jean-Paul Nguyen
- Service de Neurochirurgie, Hôpital Henri Mondor, Assistance Publique-Hôpitaux de Paris, Créteil, France
| |
Collapse
|
33
|
Abstract
Functional neurosurgery involves precise surgical targeting of anatomic structures to modulate neurologic function. From its conception, advances in the surgical treatment of movement disorders have been intertwined with developments in medical imaging, culminating in the use of stereotactic magnetic resonance imaging (MRI). Meticulous attention to detail during image acquisition, direct anatomic localization, and planning of the initial surgical trajectory allows the surgeon to reach the desired anatomic and functional target with the initial trajectory in most cases, thus reducing the need for multiple passes through the brain, and the associated risk of hemorrhage and functional deficit. This philosophy is of paramount importance in a procedure that is primarily aimed at improving quality of life. Documentation of electrode contact location by means of stereotactic imaging is essential to audit surgical targeting accuracy and to further the knowledge of structure-to-function relationships within the human brain.
Collapse
|
34
|
Toda H, Sawamoto N, Hanakawa T, Saiki H, Matsumoto S, Okumura R, Ishikawa M, Fukuyama H, Hashimoto N. A novel composite targeting method using high-field magnetic resonance imaging for subthalamic nucleus deep brain stimulation. J Neurosurg 2009; 111:737-45. [PMID: 19326982 DOI: 10.3171/2008.12.jns0861] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Accurate localization of the subthalamic nucleus (STN) is important for proper placement of the electrodes in deep brain stimulation (DBS) surgery for patients with advanced Parkinson disease. The authors evaluated the accuracy of our modified composite targeting method and the value of using high-field MR imaging for targeting the STN. METHODS Thirteen patients with advanced Parkinson disease underwent bilateral STN DBS based on 3-T MR imaging, and 13 patients underwent surgery based on 1.5-T MR imaging. By sequentially referring to the postmammillary commissure, the red nucleus, the mammillothalamic tract, and the STN, the modified composite targeting method determined the stereotactic coordinates for targeting the STN. The accuracy and efficacy of the composite targeting method and 3-T MR imaging were evaluated by using the intraoperative microelectrode recording, the postoperative imaging study, and the postoperative clinical improvement. RESULTS The landmark structures for targeting the STN were visualized clearly with 3-T MR imaging. The mean (+/- SD) path length through the STN of the central track was 4.9 +/- 1.1 mm in the 3-T group and 3.1 +/- 2.0 mm in the 1.5-T group (p < 0.001). Twenty-one (81%) of 26 electrodes were placed in the central track in the 3-T group, whereas 8 (31%) of 26 electrodes were placed in the central track in the 1.5-T group (p = 0.006). The rest of the electrodes were placed in the noncentral optimum track for alleviating parkinsonian motor symptoms. The mean Unified Parkinson's Disease Rating Scale motor part score during off period was reduced by 53% in the 3-T group and by 41% in the 1.5-T group (p = 0.14). The mean reductions of levodopa equivalent daily doses were 48.6% in the 3-T group and 43.7% in the 1.5-T group (p = 0.61). CONCLUSIONS The use of the modified composite targeting method referring to the multiple landmarks with 3-T MR imaging offers reliable and clinically effective target for STN DBS surgery.
Collapse
Affiliation(s)
- Hiroki Toda
- Department of Neurosurgery, Tazuke Kofukai Medical Research Institute and Kitano Hospital, Osaka, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
35
|
Daniluk S, Davies KG, Novak P, Vu T, Nazzaro JM, Ellias SA. Isolation of the brain-related factor of the error between intended and achieved position of deep brain stimulation electrodes implanted into the subthalamic nucleus for the treatment of Parkinson's disease. Neurosurgery 2009; 64:374-82; discussion 382-4. [PMID: 19404117 DOI: 10.1227/01.neu.0000335171.38334.39] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE Although a few studies have quantified errors in the implantation of deep brain stimulation electrodes into the subthalamic nucleus (STN), a significant trend in error direction has not been reported. We have previously found that an error in axial plane, which is of most concern because it cannot be compensated for during deep brain stimulation programming, had a posteromedial trend. We hypothesized that this trend results from a predominance of a directionally oriented error factor of brain origin. Accordingly, elimination of nonbrain (technical) error factors could augment this trend. Thus, implantation accuracy could be improved by anterolateral compensation during target planning. METHODS Surgical technique was revised to minimize technical error factors. During 22 implantations, targets were selected on axial magnetic resonance imaging scans up to 1.5 mm anterolateral from the STN center. Using fusion of postoperative computed tomographic and preoperative magnetic resonance imaging scans, implantation errors in the axial plane were obtained and compared with distances from the lead to the STN to evaluate the benefit of anterolateral compensation. RESULTS Twenty errors and the mean error had a posteromedial direction. The average distances from the lead to the target and to the STN were 1.7 mm (range, 0.8-3.1 mm) and 1.1 mm (range, 0.1-1.9 mm), respectively. The difference between the 2 distances was significant (paired t test, P < 0.0001). The lower parts of the lead were consistently bent in the posteromedial direction on postoperative scout computed tomographic scans, suggesting that a brain-related factor is responsible for the reported error. CONCLUSION Elimination of the technical factors of error during STN deep brain stimulation implantation can result in a consistent posteromedial error. Implantation accuracy may be improved by compensation for this error in advance.
Collapse
Affiliation(s)
- Slawomir Daniluk
- Department of Neurosurgery, Boston University Medical Center, Boston, Massachusetts 02118, USA.
| | | | | | | | | | | |
Collapse
|
36
|
Contact position analysis of deep brain stimulation electrodes on post-operative CT images. Acta Neurochir (Wien) 2009; 151:823-9; discussion 829. [PMID: 19444372 DOI: 10.1007/s00701-009-0393-3] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2008] [Accepted: 08/28/2008] [Indexed: 10/20/2022]
Abstract
PURPOSE Groups performing deep brain stimulation advocate post-operative imaging [magnetic resonance imaging (MRI) or computer tomography (CT)] to analyse the position of each electrode contact. The artefact of the Activa 3389 electrode had been described for MRI but not for CT. We undertook an electrode artefact analysis for CT imaging to obtain information on the artefact dimensions and related electrode contact positions. METHODS The electrode was fixed on a phantom in a set position and six acquisitions were run (in-vitro study). The artefacts were compared with the real electrode position. Ten post-operative acquisitions were analysed (in-vivo analysis). We measured: H (height of the lateral black artefact), D (distance between the beginning of the white and the lateral black artefacts) and W (maximal artefact width), representing respectively the lengths of the four contacts and the electrode tip and width of the contact zone. A Student t-test compared the results: in vivo vs in vitro and coronal vs sagittal reconstructions along the electrode. RESULTS The limits of the lateral black artefact around the electrode contacts corresponded to the final electrode position. There was no significant difference for D (in vivo, 1.1 +/- 0.1 mm; in vitro, 1.2 +/- 0.2 mm; p = 0.213), while W and H differed slightly (in vivo, W = 3.3 +/- 0.2 mm, H = 7.7 +/- 0.2 mm; in vitro, W = 3.1 +/- 0.1 mm, H = 7.5 +/- 0.2 mm). Results obtained with sagittal and coronal reconstructions were similar (p > 0.6). CONCLUSIONS Precise three-dimensional (3D) localisation of the four-contact zone of the electrode can be obtained by CT identification of the limits of the lateral black artefact. The relative position of the four contacts is deduced from the size of the contacts and the inter-contact distance. Sagittal and coronal reconstructions along the electrode direction should be considered for the identification of the four electrode contacts. CT offers a useful alternative to post-operative MRI.
Collapse
|
37
|
Deep Brain Stimulation of the Posterior Hypothalamus in Chronic Cluster Headache. Neuromodulation 2009. [DOI: 10.1016/b978-0-12-374248-3.00040-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
38
|
Franzini A, Leone M, Messina G, Cordella R, Marras C, Bussone G, Broggi G. Neuromodulation in treatment of refractory headaches. Neurol Sci 2008; 29 Suppl 1:S65-8. [DOI: 10.1007/s10072-008-0891-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
39
|
Hemm S, Caire F, Coste J, Vassal F, Nuti C, Derost P, Ouchchane L, Sarry L, Durif F, Lemaire JJ. Postoperative control in deep brain stimulation of the subthalamic region: the contact membership concept. Int J Comput Assist Radiol Surg 2008. [DOI: 10.1007/s11548-008-0152-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
40
|
Yoshida F, Miyagi Y, Morioka T, Hashiguchi K, Murakami N, Matsumoto K, Nagata S, Sasaki T. Assessment of Contact Location in Subthalamic Stimulation for Parkinson’s Disease by Co-Registration of Computed Tomography Images. Stereotact Funct Neurosurg 2008; 86:162-6. [DOI: 10.1159/000120428] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
41
|
Larson PS, Richardson RM, Starr PA, Martin AJ. Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series. Stereotact Funct Neurosurg 2007; 86:92-100. [PMID: 18073522 DOI: 10.1159/000112430] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Magnetic resonance imaging (MRI) is a commonly used and important imaging modality to evaluate lead location and rule out complications after deep brain stimulation (DBS) surgery. Recent safety concerns have prompted new safety recommendations for the use of MRI in these patients, including a new recommendation to limit the specific absorption rate (SAR) of the MRI sequences used to less than 0.1 W/kg. Following SAR recommendations in real-world situations is problematic for a variety of reasons. We review our experience scanning patients with implanted DBS systems over a 7-year period using a variety of scanning techniques and four scanning platforms. 405 patients with 746 implanted DBS systems were imaged using 1.5-tesla MRI with an SAR of up to 3 W/kg. Many of the DBS systems were imaged multiple times, for a total of 1,071 MRI events in this group of patients with no adverse events. This series strongly suggests that the 0.1 W/kg recommendation for SAR may be unnecessarily low for the prevention of MRI-related adverse events.
Collapse
Affiliation(s)
- Paul S Larson
- Department of Neurological Surgery, University of California, San Francisco, CA 94143-0112, USA.
| | | | | | | |
Collapse
|
42
|
Lemaire JJ, Coste J, Ouchchane L, Hemm S, Derost P, Ulla M, Siadoux S, Gabrillargues J, Durif F, Chazal J. MRI anatomical mapping and direct stereotactic targeting in the subthalamic region: functional and anatomical correspondence in Parkinson’s disease. Int J Comput Assist Radiol Surg 2007. [DOI: 10.1007/s11548-007-0124-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
43
|
Herzog J, Hamel W, Wenzelburger R, Pötter M, Pinsker MO, Bartussek J, Morsnowski A, Steigerwald F, Deuschl G, Volkmann J. Kinematic analysis of thalamic versus subthalamic neurostimulation in postural and intention tremor. ACTA ACUST UNITED AC 2007; 130:1608-25. [PMID: 17439979 DOI: 10.1093/brain/awm077] [Citation(s) in RCA: 150] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Deep brain stimulation of the thalamus (thalamic DBS) is an established therapy for medically intractable essential tremor and tremor caused by multiple sclerosis. In both disorders, motor disability results from complex interaction between kinetic tremor and accompanying ataxia with voluntary movements. In clinical studies, the efficacy of thalamic DBS has been thoroughly assessed. However, the optimal anatomical target structure for neurostimulation is still debated and has never been analysed in conjunction with objective measurements of the different aspects of motor impairment. In 10 essential tremor and 11 multiple sclerosis patients, we analysed the effect of thalamic DBS through each contact of the quadripolar electrode on the contralateral tremor rating scale, accelerometry and kinematic measures of reach-to-grasp-movements. These measures were correlated with the anatomical position of the stimulating electrode in stereotactic space and in relation to nuclear boundaries derived from intraoperative microrecording. We found a significant impact of the stereotactic z-coordinate of stimulation contacts on the TRS, accelerometry total power and spatial deviation in the deceleration and target period of reach-to-grasp-movements. Most effective contacts clustered within the subthalamic area (STA) covering the posterior Zona incerta and prelemniscal radiation. Stimulation within this region led to a mean reduction of the lateralized tremor rating scale by 15.8 points which was significantly superior to stimulation within the thalamus (P < 0.05, student's t-test). STA stimulation resulted in reduction of the accelerometry total power by 99%, whereas stimulation at the ventral thalamic border (68%) or within the thalamus proper (2.5%) was significantly less effective (P < 0.01). Concomitantly, STA stimulation led to a significantly higher increase of tremor frequency and decrease in EMG synchronization compared to stimulation within the thalamus proper (P < 0.001). In reach-to-grasp movements, STA stimulation reduced the spatial variability of the movement path in the deceleration period by 28.9% and in the target period by 58.4%, whereas stimulation within the thalamus was again significantly less effective (P < 0.05), with a reduction in the deceleration period between 6.5 and 21.8% and in the target period between 1.2 and 11.3%. An analysis of the nuclear boundaries from intraoperative microrecording confirmed the anatomical impression that most effective electrodes were located within the STA. Our data demonstrate a profound effect of deep brain stimulation of the thalamic region on tremor and ataxia in essential tremor and tremor caused by multiple sclerosis. The better efficacy of stimulation within the STA compared to thalamus proper favours the concept of a modulation of cerebello-thalamic projections underlying the improvement of these symptoms.
Collapse
Affiliation(s)
- Jan Herzog
- Department of Neurology, Christian Albrechts University Kiel, Germany
| | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Pinto S, Le Bas JF, Castana L, Krack P, Pollak P, Benabid AL. COMPARISON OF TWO TECHNIQUES TO POSTOPERATIVELY LOCALIZE THE ELECTRODE CONTACTS USED FOR SUBTHALAMIC NUCLEUS STIMULATION. Oper Neurosurg (Hagerstown) 2007; 60:285-92; discussion 292-4. [PMID: 17415165 DOI: 10.1227/01.neu.0000255353.64077.a8] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE Cerebral ventriculography (Vg) and magnetic resonance imaging (MRI) scanning are routine procedures to determine the implanted electrode placement into the subthalamic nucleus (STN) and are used in several centers that provide deep brain stimulation for Parkinson's disease patients. However, because of image distortion, MRI scan accuracy in determining electrode placement is still matter of debate. The objectives of this study were to verify the expected localization of the electrode contacts within the STN and to compare the stereotactic coordinates of these contacts determined intraoperatively by Vg with those calculated postoperatively by MRI scans. To our knowledge, this is the first study attempting to compare the "gold standard" of stereotactic accuracy (Vg) with the anatomic resolution provided by MRI scans. METHODS Images from 18 patients with Parkinson's disease who underwent bilateral operation were used in this study. Among the 36 chronically stimulated contacts, 28 contacts (78%) were localized in the dorsolateral part of the STN. The remaining eight contacts (22%) were located more dorsally in the zona incerta, close to the upper border of the STN. RESULTS Significant differences were found between Vg and MRI scans regarding the mediolateral x coordinate of the contacts for both left and right electrodes and regarding the right-sided anteroposterior y coordinate. No statistical difference was found for the left-sided y coordinate and the dorsoventral z coordinate for both sides. CONCLUSION If we assume that Vg is an imaging gold standard, our results suggest that postoperative MRI scanning may induce a slight image translation compared with Vg. However, MRI scans allowed localization of most of the contacts within the STN.
Collapse
Affiliation(s)
- Serge Pinto
- Department of Neurology, Centre Hospitalier Universitaire de Grenoble, and INSERM U318, Neurosciences Précliniques, Grenoble, France.
| | | | | | | | | | | |
Collapse
|
45
|
Franzini A, Marras C, Tringali G, Leone M, Ferroli P, Bussone G, Bugiani O, Broggi G. Chronic high frequency stimulation of the posteromedial hypothalamus in facial pain syndromes and behaviour disorders. ACTA NEUROCHIRURGICA. SUPPLEMENT 2007; 97:399-406. [PMID: 17691328 DOI: 10.1007/978-3-211-33081-4_45] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Chronic high frequency stimulation (HFS) of the posteromedial hypothalamus (PMH) has been the first direct therapeutic application of functional neuroimaging data in a restorative reversible procedure for the treatment of an otherwise refractory neurological condition; in fact, the target coordinates for the stereotactic implantation of the electrodes have been provided by positron emission tomography (PET) studies, which were performed during cluster headache attacks. HFS of PMH produced a significant and marked reduction of pain attacks in patients with chronic cluster headache (CCH) and in one patient with short-lasting unilateral neuralgiform headache attacks with conjunctival injection and tearing (SUNCT). The episodes of violent behaviour and psychomotor agitation during the attacks of CCH supported the idea that the posteromedial hypothalamus could be also involved in the control of aggressiveness; this has been previously suggested, in the seventies, by the results obtained in Sano's hypothalamotomies for the treatment of abnormal aggression and disruptive behaviour. On the basis of these considerations, we have performed HFS of the PMH and controlled successfully violent and disruptive behaviour in patients refractory to the conventional sedative drugs. Finally, we also tested the same procedure in three patients with refractory atypical facial pain, but unfortunately, they did not respond to this treatment.
Collapse
Affiliation(s)
- A Franzini
- Department of Neurosurgery, Istituto Nazionale Neurologico Carlo Besta, Milano, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
46
|
Picozzi P, Rizzo G, Landoni C, Attuati L, Franzin A, Messa C, Ferrari da Passano C, Bettinardi V, Fazio F. A Simplified Method to Integrate Metabolic Images in Stereotactic Procedures Using a PET/CT Scanner. Stereotact Funct Neurosurg 2006; 83:208-12. [PMID: 16534252 DOI: 10.1159/000091951] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
We have developed a method that needs only the computed tomography (CT) indicator box to coregister positron emission tomography (PET) images and integrates this information with magnetic resonance imaging. The study was performed using a PET/CT scanner. A standard CT bed adapter was attached to the scanner couch. Then, the patient, with the Leksell G frame fixed, was positioned into the scanner with the CT indicator box. PET images were acquired using either [18F]fluorodeoxyglucose or [11C]choline as radioisotopes. After acquisition, CT and PET images were exported in DICOM 3 standard and transferred to a dedicated workstation via data link. Homemade software was implemented for multimodal image fusion. PET images were overwritten to their corresponding CT point values using a threshold algorithm, maintaining the stereotactic CT markers. The use of a CT indicator simplifies the procedure, because there is no need for a radioactive solution filling the indicator box. This method was tested first using a phantom and then in patients. The localization accuracy of the PET images is limited only by the slice thickness.
Collapse
Affiliation(s)
- Piero Picozzi
- Department of Neurosurgery, IRCCS, Ospedale San Raffaele, Vita Salute University, Milan, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Broggi G, Franzini A, Tringali G, Ferroli P, Marras C, Romito L, Maccagnano E. Deep brain stimulation as a functional scalpel. ACTA NEUROCHIRURGICA. SUPPLEMENT 2006; 99:13-9. [PMID: 17370756 DOI: 10.1007/978-3-211-35205-2_2] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Since 1995, at the Istituto Nazionale Neurologico "Carlo Besta" in Milan (INNCB,) 401 deep brain electrodes were implanted to treat several drug-resistant neurological syndromes (Fig. 1). More than 200 patients are still available for follow-up and therapeutical considerations. In this paper our experience is reviewed and pioneered fields are highlighted. The reported series of patients extends the use of deep brain stimulation beyond the field of Parkinson's disease to new fields such as cluster headache, disruptive behaviour, SUNCt, epilepsy and tardive dystonia. The low complication rate, the reversibility of the procedure and the available image guided surgery tools will further increase the therapeutic applications of DBS. New therapeutical applications are expected for this functional scalpel.
Collapse
Affiliation(s)
- G Broggi
- Department of Neurosurgery, Istituto Nazionale Neurologico C. Besta, Milano, Italy.
| | | | | | | | | | | | | |
Collapse
|
48
|
Rezai AR, Kopell BH, Gross RE, Vitek JL, Sharan AD, Limousin P, Benabid AL. Deep brain stimulation for Parkinson's disease: Surgical issues. Mov Disord 2006; 21 Suppl 14:S197-218. [PMID: 16810673 DOI: 10.1002/mds.20956] [Citation(s) in RCA: 119] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Numerous factors need to be taken into account when implanting deep brain stimulation (DBS) systems into patients with Parkinson's disease. The surgical procedure itself can be divided into immediate preoperative, intraoperative, and immediate postoperative phases. Preoperative considerations include medication withdrawal issues, stereotactic equipment choices, imaging modalities, and targeting strategy. Intraoperative considerations focus on methods for physiological confirmation of a given target for DBS electrode deployment. Terms such as microelectrode recording, microstimulation, and macrostimulation will be defined to clarify inconsistencies in the literature. Advantages and disadvantages of each technique will be addressed. Furthermore, operative decisions such as staging, choice of electrode and implantable pulse generator, and methods of device fixation will be outlined. Postoperative issues include imaging considerations, including magnetic resonance safety, device-device interactions, and immediate surgical complications pertaining to the DBS procedure. This report outlines answers to a series of questions developed to address all aspects of the DBS surgical procedure and decision-making with a systematic overview of the literature (until mid-2004) and by the expert opinion of the authors. This is a report from the Consensus on Deep Brain Stimulation for Parkinson's Disease, a project commissioned by the Congress of Neurological Surgeons and the Movement Disorder Society. It outlines answers to a series of questions developed to address all surgical aspects of deep brain stimulation.
Collapse
Affiliation(s)
- Ali R Rezai
- Department of Neurosurgery, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA.
| | | | | | | | | | | | | |
Collapse
|
49
|
Franzini A, Marras C, Ferroli P, Bugiani O, Broggi G. Stimulation of the Posterior Hypothalamus for Medically Intractable Impulsive and Violent Behavior. Stereotact Funct Neurosurg 2005; 83:63-6. [PMID: 15990469 DOI: 10.1159/000086675] [Citation(s) in RCA: 78] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To describe the therapeutic effect of deep brain stimulation for the treatment of patients with below-average IQs who are affected by aggressive and disruptive behavior and who are resistant to any drug and/or conservative treatment (including occupational therapy). PATIENTS AND METHODS Two consecutive patients suffering from mental retardation with aggressive and disruptive behavior and resistant to any pharmacological treatment underwent deep brain stimulation electrode placement in the posteromedial hypothalamus for continuous chronic high-frequency stimulation (HFS). The stereotactic coordinates of the target were chosen according to the study by Sano et al., which involved hypothalamic stereotactic lesions. RESULTS HFS of the posteromedial hypothalamus demonstrated consistent improvement of disruptive behavior in both patients at the follow-up evaluation 1 year later. CONCLUSIONS HFS of the posteromedial hypothalamus showed similar results to those obtained by Sano et al. in the 1960s with radiofrequency lesions of the same target volume. The reversibility of neurostimulation allows HFS to control disruptive behavior when conservative treatments are ineffective, and drug therapy is uneventful or causes severe side effects. In conclusion, this neuromodulation procedure improved the quality of life and the range of social relationships for both of the treated patients.
Collapse
Affiliation(s)
- Angelo Franzini
- Department of Neurosurgery, Istituto Nazionale Neurologico Carlo Besta, Milan, Italy.
| | | | | | | | | |
Collapse
|
50
|
Franzini A, Marras C, Ferroli P, Zorzi G, Bugiani O, Romito L, Broggi G. Long-term high-frequency bilateral pallidal stimulation for neuroleptic-induced tardive dystonia. J Neurosurg 2005; 102:721-5. [PMID: 15871516 DOI: 10.3171/jns.2005.102.4.0721] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
✓ The authors report the results of long-term bilateral high-frequency pallidal stimulation in two patients affected by neuroleptic-induced dystonia.
The first patient, a 33-year-old man, experienced a dystonic posture of the trunk, with involvement of the neck and upper and lower limbs after 11 years of treatment with neuroleptic drugs. The second patient, a 30-year-old man, presented with a torsion dystonia, spasmodic torticollis, and involuntary movements of the upper limbs, which appeared after 4 years of neuroleptic treatment. Both of these dystonias worsened even after the neuroleptic treatment had been discontinued, and neither patient responded to clozapine or benzodiazepine therapy. The time lapse between the first appearance of dystonia and surgery was, respectively, 5 and 3 years. In each case bilateral stereotactic implantation of electrodes within the globus pallidus internus (GPI) was performed while the patient was in a state of general anesthesia. The electrodes were placed at the following anterior commissure—posterior commissure line—related coordinates: 20 mm lateral to the midline, 6 mm below the intercommissural plane, and 3 mm anterior to the midcommissural point. Electrical stimulation (130 Hz, 1 V, 90 µsec) was begun on the 1st postoperative day. In both patients, a genetic analysis positively ruled out a mutation in the DYT1 gene, and magnetic resonance imaging yielded normal findings in both cases.
Extrapyramidal symptoms and dystonia disappeared almost completely and dramatically in both patients just a few days after high-frequency bilateral pallidal stimulation commenced. Both patients regained autonomy and neuroleptic treatment was reinitiated. The follow-up period for both cases was 1 year. Long-term bilateral high-frequency stimulation of GPI resulted in a dramatic and long-lasting improvement of neuroleptic-induced tardive dystonia.
Collapse
Affiliation(s)
- Angelo Franzini
- Department of Neurosurgery, Division of Child Neurology, and Department of Neurology, Istituto Nazionale Neurologico Carlo Besta, Milano, Italy.
| | | | | | | | | | | | | |
Collapse
|