1
|
Abstract
Non-invasive external magnetic resonance imaging (MRI) of large vessel atherosclerosis is a robust and promising imaging modality that can be applied for the evaluation of the atherosclerotic process in large vessels. However, it requires expertise for setup and time for data acquisition and analysis. Intravascular MRI is a promising tool, but its use remains at the pre-clinical stage within selected research groups. In this review, the current status and future role of intravascular MRI for atherosclerotic plaque characterization are summarized, along with important challenges which will be necessary to overcome prior to the wide adoption of this technique.
Collapse
Affiliation(s)
- João L Cavalcante
- Department of Medicine, Division of Cardiology, UPMC Heart & Vascular Institute, University of Pittsburgh, Pittsburgh, PA, USA
| | - Eric Larose
- Faculté de médecine, Université Laval, Quebec, Quebec, Canada.
- Centre de recherche de l'Institut universitaire de cardiologie et de pneumologie de Québec - Université Laval, 2725 chemin Sainte-Foy, Quebec, Quebec, G1V 4G5, Canada.
| |
Collapse
|
2
|
Qian D, Bottomley PA. High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T. J Cardiovasc Magn Reson 2012; 14:20. [PMID: 22448884 PMCID: PMC3340302 DOI: 10.1186/1532-429x-14-20] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2011] [Accepted: 03/26/2012] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The thickness of fibrous caps (FCT) of atherosclerotic lesions is a critical factor affecting plaque vulnerability to rupture. This study tests whether 3 Tesla high-resolution intravascular cardiovascular magnetic resonance (CMR) employing tiny loopless detectors can identify lesions and accurately measure FCT in human arterial specimens, and whether such an approach is feasible in vivo using animal models. METHODS Receive-only 2.2 mm and 0.8 mm diameter intravascular loopless CMR detectors were fabricated for a clinical 3 Tesla MR scanner, and the absolute signal-to-noise ratio determined. The detectors were applied in a two-step protocol comprised of CMR angiography to identify atherosclerotic lesions, followed by high-resolution CMR to characterize FCT, lesion size, and/or vessel wall thickness. The protocol was applied in fresh human iliac and carotid artery specimens in a human-equivalent saline bath. Mean FCT measured by 80 μm intravascular CMR was compared with histology of the same sections. In vivo studies compared aortic wall thickness and plaque size in healthy and hyperlipidemic rabbit models, with post-mortem histology. RESULTS Histology confirmed plaques in human specimens, with calcifications appearing as signal voids. Mean FCT agreed with histological measurements within 13% on average (correlation coefficient, R = 0.98; Bland-Altman analysis, -1.3 ± 68.9 μm). In vivo aortic wall and plaque size measured by 80 μm intravascular CMR agreed with histology. CONCLUSION Intravascular 3T CMR with loopless detectors can both locate atherosclerotic lesions, and accurately measure FCT at high-resolution in a strategy that appears feasible in vivo. The approach shows promise for quantifying vulnerable plaque for evaluating experimental therapies.
Collapse
Affiliation(s)
- Di Qian
- Division of MR Research, Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| | - Paul A Bottomley
- Division of MR Research, Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
- Division of MR Research, Department of Radiology and Radiological Science, Johns Hopkins School of Medicine, 600 N Wolfe St, Park 310, Baltimore, MD, USA
| |
Collapse
|
3
|
Seo CH, Shi Y, Huang SW, Kim K, O'Donnell M. Thermal strain imaging: a review. Interface Focus 2011; 1:649-64. [PMID: 22866235 PMCID: PMC3262277 DOI: 10.1098/rsfs.2011.0010] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2011] [Accepted: 04/21/2011] [Indexed: 11/12/2022] Open
Abstract
Thermal strain imaging (TSI) or temporal strain imaging is an ultrasound application that exploits the temperature dependence of sound speed to create thermal (temporal) strain images. This article provides an overview of the field of TSI for biomedical applications that have appeared in the literature over the past several years. Basic theory in thermal strain is introduced. Two major energy sources appropriate for clinical applications are discussed. Promising biomedical applications are presented throughout the paper, including non-invasive thermometry and tissue characterization. We present some of the limitations and complications of the method. The paper concludes with a discussion of competing technologies.
Collapse
Affiliation(s)
| | - Yan Shi
- Philips Research, Briarcliff Manor, NY, USA
| | | | - Kang Kim
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Matthew O'Donnell
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| |
Collapse
|
4
|
Kramer CM, Narula J. Whither catheter-based intravascular magnetic resonance imaging of atherosclerosis? JACC Cardiovasc Imaging 2011; 3:1203-4. [PMID: 21071014 DOI: 10.1016/j.jcmg.2010.10.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
5
|
Abstract
Critical coronary stenoses have been shown to contribute to only a minority of acute coronary syndromes (ACS) and sudden cardiac death. Autopsy studies have identified a subgroup of high-risk patients with disrupted vulnerable plaque and modest stenosis. Consequently, a clinical need exists to develop methods to identify these plaques prospectively before disruption and clinical expression of disease. Recent advances in invasive and noninvasive imaging techniques have shown the potential to identify these high-risk plaques. The anatomical characteristics of the vulnerable plaque such as thin cap fibroatheroma and lipid pool can be identified with angioscopy, high frequency intravascular ultrasound, intravascular MRI, and optical coherence tomography. Efforts have also been made to recognize active inflammation in high-risk plaques using intravascular thermography. Plaque chemical composition by measuring electromagnetic radiation using spectroscopy is also an emerging technology to detect vulnerable plaques. Noninvasive imaging with MRI, CT, and PET also holds the potential to differentiate between low and high-risk plaques. However, at present none of these imaging modalities are able to detect vulnerable plaque neither has been shown to definitively predict outcome. Nevertheless in contrast, there has been a parallel development in the physiological assessment of advanced atherosclerotic coronary artery disease. Thus recent trials using fractional flow reserve in patients with modest non flow-limiting stenoses have shown that deferral of PCI with optimal medical therapy in these patients is superior to coronary intervention. Further trials are needed to provide more information regarding the natural history of high-risk but non flow-limiting plaque to establish patient-specific targeted therapy and to refine plaque stabilizing strategies in the future.
Collapse
Affiliation(s)
- Faisal Sharif
- Department of Cardiology, St James' Hospital, St James' Street, Dublin 8, Ireland.
| | | |
Collapse
|
6
|
Watanabe Y, Nagayama M. MR plaque imaging of the carotid artery. Neuroradiology 2010; 52:253-74. [PMID: 20155353 DOI: 10.1007/s00234-010-0663-z] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2009] [Accepted: 01/13/2010] [Indexed: 02/08/2023]
Abstract
Atherosclerotic carotid plaque represents a major cause of cerebral ischemia. The detection of vulnerable plaque is important for preventing future cardiovascular events. The key factors in advanced plaque that are most likely to lead to patient complications are the condition of the fibrous cap, the size of the necrotic core and hemorrhage, and the extent of inflammatory activity within the plaque. Magnetic resonance (MR) imaging has excellent soft tissue contrast and can allow for a more accurate and objective estimation of carotid wall morphology and plaque composition. Recent advances in MR imaging techniques have permitted serial monitoring of atherosclerotic disease evolution and the identification of intraplaque risk factors for accelerated progression. The purpose of this review article is to review the current state of techniques of carotid wall MR imaging and the characterization of plaque components and surface morphology with MR imaging, and to describe the clinical practice of carotid wall MR imaging for the determination of treatment plan.
Collapse
Affiliation(s)
- Yuji Watanabe
- Department of Radiology, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki, 710-8602, Japan.
| | | |
Collapse
|
7
|
Recent developments and new perspectives on imaging of atherosclerotic plaque: role of anatomical, cellular and molecular MRI Part I and II. Int J Cardiovasc Imaging 2010; 26:433-45. [DOI: 10.1007/s10554-009-9565-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2009] [Accepted: 12/17/2009] [Indexed: 10/19/2022]
|
8
|
|
9
|
Khadim G, Nanjundappa A, Dieter RS. Intravascular MRI. CURRENT CARDIOVASCULAR IMAGING REPORTS 2009. [DOI: 10.1007/s12410-009-0034-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
10
|
Vaina S, Stefanadis C. Detection of the vulnerable coronary atheromatous plaque. Where are we now? ACTA ACUST UNITED AC 2009; 7:75-87. [PMID: 16093216 DOI: 10.1080/14628840510011252] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Atherosclerosis is a progressive process with potentially devastating consequences and has been identified as the leading cause of morbidity and mortality, especially in the industrial countries. The underlying mechanisms include endothelial dysfunction, lipid accumulation and enhanced inflammatory involvement resulting in plaque disruption or plaque erosion and subsequent thrombosis. However, it has been made evident, that the majority of rupture prone plaques that produce acute coronary syndromes are not severely stenotic. Conversely, lipid-rich plaques with thin fibrous cap, heavily infiltrated by inflammatory cells have been shown to predispose to rupture and thrombosis, independently of the degree of stenosis. Therefore, given the importance of plaque composition, a continuously growing interest in the development and improvement of diagnostic modalities will promptly and most importantly, accurately detect and characterize the high-risk atheromatous plaque. Use of these techniques may help risk stratification and allow the selection of the most appropriate therapeutic approach.
Collapse
Affiliation(s)
- Sophia Vaina
- 1st Department of Cardiology, Medical School of Athens University, Hippokration Hospital, Athens, Greece
| | | |
Collapse
|
11
|
Choudhury RP, Fisher EA. Molecular imaging in atherosclerosis, thrombosis, and vascular inflammation. Arterioscler Thromb Vasc Biol 2009; 29:983-91. [PMID: 19213945 DOI: 10.1161/atvbaha.108.165498] [Citation(s) in RCA: 85] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Appreciation of the molecular and cellular processes of atherosclerosis, thrombosis, and vascular inflammation has identified new targets for imaging. The common goals of molecular imaging approaches are to accelerate and refine diagnosis, provide insights that reveal disease diversity, guide specific therapies, and monitor the effects of those therapies. Here we undertake a comparative analysis of imaging modalities that have been used in this disease area. We consider the elements of contrast agents, emphasizing how an understanding of the biology of atherosclerosis and its complications can inform optimal design. We address the potential and limitations of current contrast approaches in respect of translation to clinically usable agents and speculate on future applications.
Collapse
|
12
|
García-García HM, Gonzalo N, Granada JF, Regar E, Serruys PW. Diagnosis and treatment of coronary vulnerable plaques. Expert Rev Cardiovasc Ther 2008; 6:209-22. [PMID: 18248275 DOI: 10.1586/14779072.6.2.209] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Thin-capped fibroatheroma is the morphology that most resembles plaque rupture. Detection of these vulnerable plaques in vivo is essential to being able to study their natural history and evaluate potential treatment modalities and, therefore, may ultimately have an important impact on the prevention of acute myocardial infarction and death. Currently, conventional grayscale intravascular ultrasound, virtual histology and palpography data are being collected with the same catheter during the same pullback. A combination of this catheter with either thermography capability or additional imaging, such as optical coherence tomography or spectroscopy, would be an exciting development. Intravascular magnetic resonance imaging also holds much promise. To date, none of the techniques described above have been sufficiently validated and, most importantly, their predictive value for adverse cardiac events remains elusive. Very rigorous and well-designed studies are compelling for defining the role of each diagnostic modality. Until we are able to detect in vivo vulnerable plaques accurately, no specific treatment is warranted.
Collapse
|
13
|
Abstract
The purpose of this article is to review the current state of the art with respect to intravascular magnetic resonance imaging, including intravascular coils, their implementation for plaque identification and characterization, and strategies for future approaches to coronary imaging and other cardiovascular applications.
Collapse
|
14
|
Kang Kim, Sheng-Wen Huang, Hall T, Witte R, Chenevert T, O'Donnell M. Arterial Vulnerable Plaque Characterization Using Ultrasound-Induced Thermal Strain Imaging (TSI). IEEE Trans Biomed Eng 2008; 55:171-80. [DOI: 10.1109/tbme.2007.900565] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
15
|
Wang X, Rutkowsky JL, Feuerstein GZ. Imaging and molecular biomarkers of vulnerable atheromatous plaques. Biomark Med 2007; 1:23-35. [PMID: 20477458 DOI: 10.2217/17520363.1.1.23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Rupture of a vulnerable atherosclerotic plaque is the main cause of acute coronary syndromes, myocardial infarction and death. Identification of biomarkers that accurately predict the risk of plaque rupture may be a means to establish and monitor response to therapeutic intervention. This review focuses on recent advances for the use of circulating molecular biomarkers and imaging modalities to assess atherosclerotic vulnerable plaques in both preclinical models and clinical conditions.
Collapse
Affiliation(s)
- Xinkang Wang
- Wyeth Research, Translational Medicine, 500 Arcola Road, S2324, Collegeville, PA 19426, USA.
| | | | | |
Collapse
|
16
|
Christov A, Dai E, Drangova M, Liu L, Abela GS, Nash P, McFadden G, Lucas A. Optical Detection of Triggered Atherosclerotic Plaque Disruption by Fluorescence Emission Analysis¶. Photochem Photobiol 2007. [DOI: 10.1562/0031-8655(2000)0720242odotap2.0.co2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
17
|
Pessanha BS, Potter K, Kolodgie FD, Farb A, Kutys R, Mont EK, Burke AP, O'leary TJ, Virmani R. Characterization of intimal changes in coronary artery specimens with MR microscopy. Radiology 2006; 241:107-15. [PMID: 16990674 DOI: 10.1148/radiol.2411042201] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To determine if magnetic resonance (MR) microscopy can yield images sufficient for discriminating early progressive atherosclerotic lesions from nonprogressive atherosclerotic lesions in human coronary arteries. MATERIALS AND METHODS Institutional review board approval and informed consent were not required. Seventeen coronary artery segments (mean diameter, 2.8 mm +/- 1.0 [standard deviation]) were collected within 36 hours after death from 11 cadavers (six men, five women; age range at death, 33-65 years). Quantitative T1, T2, intensity-weighted (IW), and magnetization transfer (MT) maps were acquired with a 9.4-T vertical-bore magnet. Coronary artery lesions were classified as adaptive intimal thickening (AIT), pathologic intimal thickening (PIT), or intimal xanthoma (IXA). Internal anatomic fiducial landmarks and stains were applied to proximal and epicardial vessel surfaces and used to register histologic sections with MR images and thus enable comparison of MR images and Movat pentachrome-stained histologic specimens. Unique 0.0012-0.0287-cm(2) regions of interest were visually identified on quantitative T1, T2, MT, and IW maps of AIT, IXA, and PIT lesions. Distributions of T1, T2, MT, and IW values were compared with Student t and Wilcoxon two-sample tests. RESULTS MR microscopic images of nonprogressive AIT and IXA lesions revealed two intimal layers. The luminal intima had higher T1 and T2 values and lower MT values than did the medial intima; these findings were consistent with compositional differences observed in histologic sections. In the IXA lesion, T2 values of both intimal layers were markedly reduced when compared with T2 values of AIT lesions because of the accumulation of lipid-laden macrophages in both layers. Progressive PIT lesions had a typical multilayered appearance or foci with a short T2 relaxation time and low IW values; these features were not observed in AIT or IXA lesions. CONCLUSION MR microscopy enabled identification of morphologic arterial wall features that enable discrimination of progressive PIT lesions from nonprogressive AIT or IXA lesions.
Collapse
Affiliation(s)
- Breno S Pessanha
- Department of Cardiovascular Pathology and Magnetic Resonance Microscopy Facility, Armed Forces Institute of Pathology, Washington, DC, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Sailer J, Rand T, Berg A, Sulzbacher I, Peloschek P, Hölzenbein T, Lammer J. High-Resolution 3 T MR Microscopy Imaging of Arterial Walls. Cardiovasc Intervent Radiol 2006; 29:771-7. [PMID: 16755347 DOI: 10.1007/s00270-005-0051-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
PURPOSE To achieve a high spatial resolution in MR imaging that allows for clear visualization of anatomy and even histology and documentation of plaque morphology in in vitro samples from patients with advanced atherosclerosis. A further objective of our study was to evaluate whether T2-weighted high-resolution MR imaging can provide accurate classification of atherosclerotic plaque according to a modified American Heart Association classification. METHODS T2-weighted images of arteries were obtained in 13 in vitro specimens using a 3 T MR unit (Medspec 300 Avance/Bruker, Ettlingen, Germany) combined with a dedicated MR microscopy system. Measurement parameters were: T2-weighted sequences with TR 3.5 sec, TE 15-120 msec; field of view (FOV) 1.4 x 1.4; NEX 8; matrix 192; and slice thickness 600 microm. MR measurements were compared with corresponding histologic sections. RESULTS We achieved excellent spatial and contrast resolution in all specimens. We found high agreement between MR images and histology with regard to the morphology and extent of intimal proliferations in all but 2 specimens. We could differentiate fibrous caps and calcifications from lipid plaque components based on differences in signal intensity in order to differentiate hard and soft atheromatous plaques. Hard plaques with predominantly intimal calcifications were found in 7 specimens, and soft plaques with a cholesterol/lipid content in 5 cases. In all specimens, hemorrhage or thrombus formation, and fibrotic and hyalinized tissue could be detected on both MR imaging and histopathology. CONCLUSION High-resolution, high-field MR imaging of arterial walls demonstrates the morphologic features, volume, and extent of intimal proliferations with high spatial and contrast resolution in in vitro specimens and can differentiate hard and soft plaques.
Collapse
Affiliation(s)
- Johannes Sailer
- Department of Angiography and Interventional Radiology, University of Vienna, Vienna, Austria.
| | | | | | | | | | | | | |
Collapse
|
19
|
Elgort DR, Hillenbrand CM, Zhang S, Wong EY, Rafie S, Lewin JS, Duerk JL. Image-guided and -monitored renal artery stenting using only MRI. J Magn Reson Imaging 2006; 23:619-27. [PMID: 16555228 DOI: 10.1002/jmri.20554] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To demonstrate the ability of a unique interventional MR system to be used safely and effectively as the only imaging modality for all phases of MR-guided stent-supported angioplasty. MATERIALS AND METHODS An experimental disease model of renal stenosis was created in six pigs. An interventional MR system, which employed previously reported tools for real-time catheter tracking with automated scan-plane positioning, adaptive image parameters, and radial true-FISP imaging with steady-state precession (True-FISP) imaging coupled with a high-speed reconstruction technique, was then used to guide all phases of the intervention, including: guidewire and catheter insertion, stent deployment, and confirmation of therapeutic success. Pre- and postprocedural X-ray imaging was used as a gold standard to validate the experimental results. RESULTS All of the stent-supported angioplasty interventions were a technical success and were performed without complications. The average postoperative residual stenosis was 14.9%. The image guidance enabled the stents to be deployed with an accuracy of 0.98 +/- 0.69 mm. Additionally, using this interventional MRI system to guide renal artery stenting significantly reduces the procedure time, as compared to using X-ray fluoroscopy. CONCLUSION This study has clearly demonstrated the first successful treatment of renal artery stenting in an experimental animal model solely under MRI guidance and monitoring.
Collapse
Affiliation(s)
- Daniel R Elgort
- Department of Radiology, University Hospitals of Cleveland, Cleveland, Ohio 044106, USA
| | | | | | | | | | | | | |
Collapse
|
20
|
Nasu K, Tsuchikane E, Katoh O, Vince DG, Virmani R, Surmely JF, Murata A, Takeda Y, Ito T, Ehara M, Matsubara T, Terashima M, Suzuki T. Accuracy of In Vivo Coronary Plaque Morphology Assessment. J Am Coll Cardiol 2006; 47:2405-12. [PMID: 16781367 DOI: 10.1016/j.jacc.2006.02.044] [Citation(s) in RCA: 408] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2005] [Revised: 01/27/2006] [Accepted: 02/07/2006] [Indexed: 11/19/2022]
Abstract
OBJECTIVES The goal of the present study was to compare the accuracy of in vivo tissue characterization obtained by intravascular ultrasound (IVUS) radiofrequency (RF) data analysis, known as Virtual Histology (VH), to the in vitro histopathology of coronary atherosclerotic plaques obtained by directional coronary atherectomy. BACKGROUND Vulnerable plaque leading to acute coronary syndrome (ACS) has been associated with specific plaque composition, and its characterization is an important clinical focus. METHODS Virtual histology IVUS images were performed before and after a single debulking cut using directional coronary atherectomy. Debulking region of in vivo histology image was predicted by comparing pre- and post-debulking VH images. Analysis of VH images with the corresponding tissue cross section was performed. RESULTS Fifteen stable angina pectoris (AP) and 15 ACS patients were enrolled. The results of IVUS RF data analysis correlated well with histopathologic examination (predictive accuracy from all patients data: 87.1% for fibrous, 87.1% for fibro-fatty, 88.3% for necrotic core, and 96.5% for dense calcium regions, respectively). In addition, the frequency of necrotic core was significantly higher in the ACS group than in the stable AP group (in vitro histopathology: 22.6% vs. 12.6%, p = 0.02; in vivo virtual histology: 24.5% vs. 10.4%, p = 0.002). CONCLUSIONS Correlation of in vivo IVUS RF data analysis with histopathology shows a high accuracy. In vivo IVUS RF data analysis is a useful modality for the classification of different types of coronary components, and may play an important role in the detection of vulnerable plaque.
Collapse
Affiliation(s)
- Kenya Nasu
- Department of Cardiology, Toyohashi Heart Center, Toyohashi-city, Aichi, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Koops A, Ittrich H, Petri S, Priest A, Stork A, Lockemann U, Adam G, Weber C. Multicontrast-weighted magnetic resonance imaging of atherosclerotic plaques at 3.0 and 1.5 Tesla: ex-vivo comparison with histopathologic correlation. Eur Radiol 2006; 17:279-86. [PMID: 16642325 DOI: 10.1007/s00330-006-0265-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2005] [Revised: 03/01/2006] [Accepted: 03/24/2006] [Indexed: 11/26/2022]
Abstract
The purpose was to analyze magnetic resonance (MR) plaque imaging at 3.0 Tesla and 1.5 Tesla in correlation with histopathology. MR imaging (MRI) of the abdominal aorta and femoral artery was performed on seven corpses using T1-weighted, T2-weighted, and PD-weighted sequences at 3.0 and 1.5 Tesla. Cross-sectional images at the branching of the inferior mesenteric artery and the profunda femoris were rated with respect to image quality. Corresponding cross sections of the imaged vessels were obtained at autopsy. The atherosclerotic plaques in the histological slides and MR images were classified according to the American Heart Association (AHA) and analyzed for differences. MRI at 3.0 Tesla offered superior depiction of arterial wall composition in all contrast weightings, rated best for T2-weighted images. Comparing for field strength, the highest differences were observed in T1-weighted and T2-weighted techniques (both P< or =0.001), with still significant differences in PD-weighted sequence (P< or =0.005). The majority of plaques were histologically classified as calcified plaques. In up to 21% of the cases, MRI at both field strengths detected signal loss characteristic of calcification although calcified plaque was absent in histology. MRI at 3.0 Tesla offers superior plaque imaging quality compared with 1.5 Tesla, but further work is necessary to determine whether this translates in superior diagnostic accuracy.
Collapse
Affiliation(s)
- Andreas Koops
- Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Wilensky RL, Song HK, Ferrari VA. Role of Magnetic Resonance and Intravascular Magnetic Resonance in the Detection of Vulnerable Plaques. J Am Coll Cardiol 2006; 47:C48-56. [PMID: 16631510 DOI: 10.1016/j.jacc.2005.11.048] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2005] [Revised: 11/08/2005] [Accepted: 11/12/2005] [Indexed: 10/24/2022]
Abstract
Noninvasive magnetic resonance imaging (MRI) has been used to determine vascular three-dimensional structure, detect the presence of subclinical atherosclerotic disease in high-risk patient subgroups, and optimize and follow therapy in individual patients. The outstanding soft-tissue-characterizing capabilities of MRI permit depiction of various components of atherothrombotic plaque, including lipid, fibrous tissue, calcium, and thrombus formation. However, noninvasive MRI visualization of coronary arteries is currently limited by the small size of the coronary arteries, the deep arterial location, and arterial motion. The combination of MR imaging and molecular probes offers exciting possibilities of direct visualization of biologic processes within atherosclerotic tissue. The self-contained intravascular MRI probe appears to hold promise in the identification of high-risk coronary atherosclerotic lesions with increased superficial lipid content.
Collapse
Affiliation(s)
- Robert L Wilensky
- Cardiovascular Division, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
| | | | | |
Collapse
|
23
|
Abstract
AIM To evaluate the potential role of carotid artery atherosclerosis plaque magnetic resonance (MR) microimaging as magnetic resonance imaging (MRI) marker, ex vivo MR images were acquired at optimized parameters on 9.4T Bruker animal imager for occluded tissue resected by carotid endarterectomy (CEA) and corresponding histopathological analysis was made. METHODS AND MATERIALS For imaging, CEA tissues of size 2-6 cm long and 0.5-1.5 cm wide, were transferred to 15 ml co-polymer laboratory culture tubes containing either 10% formalin in phosphate buffered saline (PBS) or in 50% glycerol in PBS. Imaging protocol was set at TE=30 ms, TR=1.5 s, matrix size=265 x 512, NEX=128, slice thickness=1 mm and in-plane resolution=0.1 mm for total sample size 2.5 cm. Soon after imaging done, carotid artery tissues were cut into 5-mm segments and processed for histological section for successive 5-micrometer slices. To compare morphology of 5 mum thin CEA section with that of 1 mm MR slices, registration was obtained between histologic sections and MR slices. Contrast and magnetic resonance relaxation characteristics were analyzed. RESULTS Total carotid artery area computed by MR imaging was correlated with areas determined from histologic sections (r(2)=0.989, p=0.0001). For the lumen area, the correlation between MR images and histologic area was (r(2)=0.942, p=0.0001). Relaxation times and T(2) parametric images of different plaque components were determinant for contrast resolution. Scan parameters were optimized for fibrous cap and atheroma. Scan parameters were characteristic for comparison at 1.5T and 9.4T MR imagers. CONCLUSION The observed correlation validated MR microimaging to assess morphological features of carotid artery plaques and contrast resolution highlighted the potential of in vivo MR imaging as non-invasive MRI marker to monitor carotid artery plaque morphometry and plaque composition.
Collapse
Affiliation(s)
- Rakesh Sharma
- Atherosclerosis Division, Department of Medicine, Baylor College of Medicine, Houston, TX 77030, USA.
| |
Collapse
|
24
|
Hofmann LV, Liddell RP, Eng J, Wasserman BA, Arepally A, Lee DS, Bluemke DA. Human peripheral arteries: feasibility of transvenous intravascular MR imaging of the arterial wall. Radiology 2005; 235:617-22. [PMID: 15858101 DOI: 10.1148/radiol.2352040340] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Feasibility of in vivo transvenous intravascular magnetic resonance (MR) imaging of the human arterial wall was determined. All subjects provided written informed consent, and institutional review board approved the study. Six arteries in six patients were imaged with a guidewire placed in the iliac vein (n = 5) or left renal vein (n = 1). Pre- and postcontrast T1-weighted and T2-weighted transvenous MR imaging were performed. An atherosclerotic plaque with a fibrous cap was identified on 27 (42%) of 64 images of veins without stents; intimal hyperplasia in a renal artery with a stent was identified on 12 images. Contrast-to-noise ratios (CNRs) on arterial wall postcontrast T1-weighted images were superior to those on images obtained with other sequences (P < .001), and the postcontrast images demonstrated the greatest number of plaques with a low-signal intensity core and fibrous cap. Preliminary results show that transvenous MR imaging is feasible for high-spatial-resolution imaging of the arterial wall and atherosclerotic plaque. Postcontrast T1-weighted imaging affords greatest CNR for the arterial wall.
Collapse
Affiliation(s)
- Lawrence V Hofmann
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Hospital, Blalock 545, 600 N Wolfe Street, Baltimore, MD 21287, USA.
| | | | | | | | | | | | | |
Collapse
|
25
|
Yang F, Holzapfel G, Schulze-Bauer C, Stollberger R, Thedens D, Bolinger L, Stolpen A, Sonka M. Segmentation of wall and plaque in in vitro vascular MR images. Int J Cardiovasc Imaging 2004; 19:419-28. [PMID: 14609192 DOI: 10.1023/a:1025829232098] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Atherosclerosis leads to heart attack and stroke, which are major killers in the western world. These cardiovascular events frequently result from local rupture of vulnerable atherosclerotic plaque. Non-invasive assessment of plaque vulnerability would dramatically change the way in which atherosclerotic disease is diagnosed, monitored, and treated. In this paper, we report a computerized method for segmentation of arterial wall layers and plaque from high-resolution volumetric MR images. The method uses dynamic programming to detect optimal borders in each MRI frame. The accuracy of the results was tested in 62 T1-weighted MR images from six vessel specimens in comparison to borders manually determined by an expert observer. The mean signed border positioning errors for the lumen, internal elastic lamina, and external elastic lamina borders were -0.1 +/- 0.1, 0.0 +/- 0.1, and -0.1 +/- 0.1 mm, respectively. The presented wall layer segmentation approach is one of the first steps towards non-invasive assessment of plaque vulnerability in atherosclerotic subjects.
Collapse
Affiliation(s)
- Fuxing Yang
- Department of Electrical and Computer Engineering, The University of Iowa, Iowa City, IA 52242, USA
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Tsekos NV, Atalar E, Li D, Omary RA, Serfaty JM, Woodard PK. Magnetic resonance imaging-guided coronary interventions. J Magn Reson Imaging 2004; 19:734-49. [PMID: 15170780 DOI: 10.1002/jmri.20071] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Magnetic resonance imaging (MRI) guidance for coronary interventions offers potential advantages over conventional x-ray angiography. Advantages include the use of nonionizing radiation, combined assessment of anatomy and function, and three-dimensional assessment of the coronary arteries leading to the myocardium. These advantages have prompted a series of recent studies in this field. Real-time coronary MR angiography, with low-dose catheter-directed intraarterial (IA) infusion of contrast media, has achieved in-plane spatial resolution as low as 0.8 x 0.8 mm2 and temporal resolution as short as 130 msec per image. Catheter-based IA injection of contrast agent has proven useful in the collection of multislice and three-dimensional images, not only for coronary intervention guidance, but also in the assessment of regional myocardial perfusion fed by the affected vessel. Actively visible guidewires and guiding catheters, based on the loopless antenna concept, have been effectively used to negotiate tortuous coronary vessels during catheterization, permitting placement of coronary angioplasty balloon catheters. Passive tracking approaches have been used to image contrast agent-filled coronary catheters and to place susceptibility-based endovascular stents. Although the field is in its infancy, these early results demonstrate the feasibility for performing MRI-guided coronary interventions. Although further methodological and technical developments are required before these methods become clinically applicable, we anticipate that MRI someday will be included in the armamentarium of techniques used to diagnose and treat coronary artery disease.
Collapse
Affiliation(s)
- Nikolaos V Tsekos
- Cardiovascular Imaging Laboratory, Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri 63110, USA.
| | | | | | | | | | | |
Collapse
|
27
|
Abstract
Atherosclerosis is currently considered to be an inflammatory and thus a systemic disease affecting multiple arterial beds. Recent advances in intravascular imaging have shown multiple sites of atherosclerotic changes in coronary arterial wall. Traditionally, angiography has been used to detect and characterize atherosclerotic plaque in coronary arteries, but recently it has been found that plaques that are not significantly stenotic on angiography cause acute myocardial infarction. As a result, newer imaging and diagnostic modalities are required to predict which of the atherosclerotic plaque are prone to rupture and hence distinguish "stable" and "vulnerable" plaques. Intravascular ultrasound can identify multiple plaques that are not seen on coronary angiography. Thermography has shown much promise and is based on the concept that the inflammatory plaques are associated with increased temperature and can also identify "vulnerable patients." Of all these newer modalities, magnetic resonance imaging has shown the most promise in identification and characterization of vulnerable plaques. In this article, we review the newer coronary artery imaging modalities and discuss the limitations of traditional coronary angiography.
Collapse
Affiliation(s)
- Vishal Bhatia
- Department of Internal Medicine, State University of New York at Buffalo, Buffalo, NY, USA.
| | | | | | | |
Collapse
|
28
|
Gillard JH. Imaging of carotid artery disease: from luminology to function? Neuroradiology 2003; 45:671-80. [PMID: 14564428 DOI: 10.1007/s00234-003-1054-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2003] [Accepted: 05/13/2003] [Indexed: 10/26/2022]
Abstract
There have been tremendous advances in our ability to image atheromatous disease, particularly in the carotid artery, which is accessible and large enough to image. The repertoire of methodology available is growing, giving anatomical information on luminal narrowing which is approaching the level at which conventional carotid angiography will become very uncommon as CT and contrast-enhanced MR angiographic techniques become the norm. More exciting is the tentative ability to perform functional plaque imaging addressing enhancement patterns and macrophage activity using MR or positron-emission tomography techniques. These techniques, once rigorously evaluated, may, in addition to complex mathematical modelling of plaque, eventually allow us to assess true plaque risk. Time will best judge whether we will be able to move from the use of simple luminology to assessment of plaque function.
Collapse
Affiliation(s)
- J H Gillard
- University Department of Radiology, Addenbrooke's Hospital, Hills Road, Cambridge CB2 2QQ, UK.
| |
Collapse
|
29
|
Stefanadis C, Vavuranakis M, Toutouzas P. Vulnerable plaque: the challenge to identify and treat it. J Interv Cardiol 2003; 16:273-80. [PMID: 12800407 DOI: 10.1034/j.1600-0854.2003.8043.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
In order to understand, treat, and prevent acute coronary syndromes we need to improve our ability to identify the rupture-prone, vulnerable atherosclerotic coronary plaque. The diagnostic modalities that are currently available to clinical practice have not fulfilled this expectation, and newer diagnostic techniques based on the recently identified features of the vulnerable plaque are quite promising. Coronary angiography, intravascular ultrasound, and angioscopy have been used in the clinical arena of interventional cardiology with several limitations regarding the identification of the vulnerable plaque. Thermography, optical coherence tomography, elastography, Raman spectroscopy, and infrared spectroscopy are used in clinical trials and the results are encouraging. Ultrafast computed tomography and magnetic resonance imaging have the advantage of being noninvasive. With our progress in the identification of the rupture-prone vulnerable coronary plaque, we will be able to identify patients that are at high risk and will benefit from a more aggressive therapeutic approach.
Collapse
|
30
|
Yang X, Atalar E, Zerhouni EA. Intravascular MR imaging and intravascular MR-guided interventions. INTERNATIONAL JOURNAL OF CARDIOVASCULAR INTERVENTIONS 2003; 2:85-96. [PMID: 12623594 DOI: 10.1080/acc.2.2.85.96] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Intravascular MR technology, using an intravascularly placed MR receiver probe to acquire high-resolution angiographic MR images (i.e. intravascular MR imaging) and to guide cardiovascular interventional therapies (i.e. intravascular MR-guided interventions), is a new, very attractive development in the field of MR imaging. The new technology offers unique advantages for cardiovascular imaging and interventions, including superior contrast capability and multiplanar imaging capabilities without the use of contrast agents and with no risk of ionizing radiation. Thecombination of intravascular MR techniques with other advanced MR imaging techniques, such as functional MR imaging, will open new avenues for the future comprehensive management of cardiovascular atherosclerotic disease. Further improvements in intravascular MR fluoroscopy with true real-time display, analogous to X-ray fluoroscopy, will dramatically establish the role of intravascular MR technology in modern medicine.
Collapse
Affiliation(s)
- Xiaoming Yang
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | | | | |
Collapse
|
31
|
Abstract
Atherosclerotic plaque stability depends on 3 factors: (1) lipid core, (2) fibrous cap and its thickness, and (3) inflammation within the cap. Magnetic resonance imaging (MRI) is a noninvasive technique that can provide information on these plaque components using a variety of pulse sequences. Assessment of plaque volume and tissue components and the efficacy of lipid-lowering therapy has been performed in human aorta and carotid arteries. Imaging the coronary wall for plaque burden is a novel application of MRI. Newer approaches also include intravascular and transesophageal MRI techniques. Several emerging MR contrast agents being tested in animal models hold promise for targeted imaging of plaque. MRI is a powerful noninvasive imaging tool with high spatial resolution that continues to prove its value in determining atherosclerotic plaque volume and tissue components.
Collapse
Affiliation(s)
- Christopher M Kramer
- Department of Radiology, and Cardiac MRI, University of Virginia Health System, Charlottesville 22908, USA.
| |
Collapse
|
32
|
Abstract
MRI is a powerful noninvasive imaging tool with high spatial resolution that continues to prove its value in determining atherosclerotic plaque size, volume, and tissue components. Multispectral MRI sequences have been validated to characterize atherosclerotic plaque components in animals; they have recently been applied to human aorta and carotid artery and are being used to identify the vulnerable plaque. The ability to measure wall thickness in human coronary artery wall has been realized. Future developments may allow plaque characterization in the coronary arteries with surface coil imaging, but intravascular MRI may play an important role in this regard. Novel contrast agents for identifying inflammation and thrombus within atherosclerotic plaque will aid in the identification of higher-risk atherosclerotic disease. Lastly, MRI has progressed to the point where it can be used in serial studies of atherosclerotic plaque progression and regression in the face of therapeutic intervention. MRI will continue to evolve an important role in imaging of atherosclerotic plaque.
Collapse
Affiliation(s)
- C Joon Choi
- Department of Internal Medicine, University of Virginia Health System, Charlottesville 22908, USA
| | | |
Collapse
|
33
|
Abstract
This work describes a real-time imaging and visualization technique that allows multiple field of view (FOV) imaging. A stream of images from a single receiver channel can be reconstructed at multiple FOVs within each image frame. Alternately, or in addition, when multiple receiver channels are available, image streams from each channel can be independently reconstructed at multiple FOVs. The implementation described here provides for real-time visualization of the placement of guidewires and catheters on a dynamic roadmap during interventional procedures. The loopless catheter antenna, an electrically active intravascular probe, was used for MR signal reception. In 2D projection images, the catheter and surrounding structures within its diameter of sensitivity appear as bright signal. The simplicity of the resulting images allows very-narrow-FOV imaging to decrease imaging time. Very-narrow-FOV images are acquired on MR receiver channels that collect guidewire or catheter data. These very-narrow-FOV images provide very high frame rate continuous, real-time imaging of the interventional devices (25 fps). Large-FOV images are formed from receiver channels that collect anatomical data from standard imaging surface coils, and simultaneously provide a dynamic, frequently updated roadmap. These multiple-FOV images are displayed together, improving visualization of interventional device placement.
Collapse
Affiliation(s)
- Pelin Aksit
- Johns Hopkins University School of Medicine, Baltimore, Maryland 21287-0845, USA
| | | | | | | |
Collapse
|
34
|
Schmitz SA, Taupitz M, Wagner S, Wolf KJ, Beyersdorff D, Hamm B. Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particles. J Magn Reson Imaging 2001; 14:355-61. [PMID: 11599058 DOI: 10.1002/jmri.1194] [Citation(s) in RCA: 174] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Experimental data show accumulation of superparamagnetic iron oxide (SPIO) particles in atherosclerotic plaques. SPIO uptake occurred in plaques, suggesting an increased endothelial permeability and macrophage infiltrates as signs of inflammatory plaque activity. We incidentally observed SPIO uptake in aortic and arterial wall segments in patients who had originally received the magnetic resonance (MR) contrast agent for staging lymph node metastases. Twenty patients (19 male, 1 female; mean age, 64; range, 41-78 years) with bladder or prostate cancer underwent MR imaging (MRI) using a T2*-weighted high-resolution gradient-echo sequence prior to and 24-36 hours after intravenous injection of 2.6 mg of Fe/kg of SPIO (Sinerem). The aorta, both common external and internal iliac, as well as both superficial femoral arteries, were retrospectively analyzed for atherosclerotic wall changes. One patient was excluded. A positive finding was defined as an area of pronounced signal loss on postcontrast images clearly confined to the arterial wall, which was absent in the precontrast examination or increased in size. Such a finding was observed in one to three arteries in 7 of the 19 patients. The pronounced signal loss in the wall of the aorta and pelvic arteries seen in part of an elderly patient population after intravenous SPIO administration strongly suggests that this contrast agent accumulates in human atherosclerotic plaques.
Collapse
Affiliation(s)
- S A Schmitz
- Abteilung für Radiologie und Nuklearmedizin, Universitätsklinikum Benjamin Franklin, Freie Universität Berlin, Berlin, Germany
| | | | | | | | | | | |
Collapse
|
35
|
Johnstone MT, Botnar RM, Perez AS, Stewart R, Quist WC, Hamilton JA, Manning WJ. In vivo magnetic resonance imaging of experimental thrombosis in a rabbit model. Arterioscler Thromb Vasc Biol 2001; 21:1556-60. [PMID: 11557688 PMCID: PMC2909772 DOI: 10.1161/hq0901.094242] [Citation(s) in RCA: 62] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The process of atherosclerotic plaque disruption has been difficult to monitor because of the lack of an animal model and the limited ability to directly visualize the plaque and overlying thrombus in vivo. Our aim was to validate in vivo magnetic resonance imaging (MRI) of the thrombus formation after pharmacological triggering of plaque disruption in the modified Constantinides animal model of plaque disruption. Atherosclerosis was induced in 9 New Zealand White male rabbits (3 kg) with aortic balloon endothelial injury followed by a high cholesterol (1%) diet for 8 weeks. After baseline (pretrigger) MRI, the rabbits underwent pharmacological triggering with Russell's viper venom and histamine, followed by another MRI 48 hours later. Contiguous cross-sectional T2-weighted fast spin echo images of the abdominal aorta were compared by histopathology. In all animals, aortic wall thickening was present on the pretrigger MRI. On MRIs performed 48 hours after triggering, a histologically confirmed intraluminal thrombus was visualized in 6 (67%) of the 9 animals. MRI data correlated with the histopathology regarding aortic wall thickness (R=0.77, P<0.0005), thrombus size (R=0.82, P<0.0001), thrombus length (R=0.86, P<0.005), and anatomic location (R=0.98, P<0.0001). In vivo, MRI reliably determines the presence, location, and size of the thrombus in this animal model of atherosclerosis and plaque disruption. The combination of in vivo MRI and the modified Constantinides animal model could be an important research tool for our understanding of the pathogenesis of acute coronary syndromes.
Collapse
Affiliation(s)
- M T Johnstone
- Department of Medicine, Cardiovascular Division, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston University School of Medicine, Boston, Massachusetts, USA.
| | | | | | | | | | | | | |
Collapse
|
36
|
Abstract
Important advances in rapid magnetic resonance (MR) imaging technology and its application to cardiovascular imaging have been made during the past decade. High-field-strength clinical magnets, high-performance gradient hardware, and ultrafast pulse sequence technology are rapidly making the vision of a comprehensive "one-stop shop" cardiac MR imaging examination a reality. This examination is poised to have a significant effect on the management of coronary artery disease by means of assessment of wall motion with tagging and pharmacologic stress testing, evaluation of the coronary microvasculature with perfusion imaging, and direct visualization of the coronary arteries with MR coronary angiography. This article reviews current state-of-the-art pulse sequence technology and its application to the evaluation of ischemic heart disease by means of MR tagging with dobutamine stress testing, MR perfusion imaging, and MR coronary angiography. Cutting edge areas of research in coil design and exciting new areas of metabolic and oxygen level-dependent imaging are also explored.
Collapse
Affiliation(s)
- S B Reeder
- Department of Radiology, Rm H1306, Stanford University, 300 Pasteur Dr, Stanford, CA 94304, USA.
| | | | | | | |
Collapse
|
37
|
Shunk KA, Garot J, Atalar E, Lima JA. Transesophageal magnetic resonance imaging of the aortic arch and descending thoracic aorta in patients with aortic atherosclerosis. J Am Coll Cardiol 2001; 37:2031-5. [PMID: 11419883 DOI: 10.1016/s0735-1097(01)01340-7] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
OBJECTIVES We sought to determine the feasibility and potential of transesophageal magnetic resonance imaging (TEMRI) for quantifying atherosclerotic plaque burden in the aortic arch and descending thoracic aorta in comparison with transesophageal echocardiography (TEE). BACKGROUND Improved morphologic assessment of atherosclerotic plaque features in vivo is of interest because of the potential for improved understanding of the pathophysiology of plaque vulnerability to rupture and progression to clinical events. Magnetic resonance imaging (MRI) is well suited for atherosclerotic plaque imaging. Performing MRI using a radio frequency (RF) receiver probe placed near the region of interest improves the signal-to-noise ratio (SNR). METHODS High-resolution images of the thoracic aortic wall were obtained by TEMRI in 22 subjects (8 normals, 14 with aortic atherosclerosis). In nine subjects, we compared aortic wall thickness and circumferential extent of atherosclerotic plaque measured by TEMRI versus TEE using a Bland-Altman analysis. Additional studies were performed in a human cadaver with pathology as an independent gold standard for assessment of atherosclerosis. RESULTS In clinical and experimental studies, we found similar measurements for aortic plaque thickness but a relative underestimation of circumferential extent of atherosclerosis by TEE (p = 0.001), due in large part to the lower SNR in the near field. CONCLUSIONS Using TEMRI allows for quantitative assessment of thoracic aortic atherosclerotic plaque burden. This technique provides good SNR in the near field, which makes it a promising approach for detailed characterization of aortic plaque burden.
Collapse
Affiliation(s)
- K A Shunk
- Department of Medicine, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | | | | | | |
Collapse
|
38
|
Demarco JK, Rutt BK, Clarke SE. Carotid plaque characterization by magnetic resonance imaging: review of the literature. Top Magn Reson Imaging 2001; 12:205-17. [PMID: 11432578 DOI: 10.1097/00002142-200106000-00006] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Magnetic resonance imaging (MRI) of carotid plaque has undergone significant improvements in the last decade. Early studies utilizing ex vivo specimens and spin-echo or fast spin-echo imaging led to the conclusion that T2 weighting is the best single contrast to characterize carotid plaque morphology. On these images, the fibrous plaque appears bright and the lipid core is dark; thrombus can have variable intensity. There can be an overlap in T2-weighted signal intensities among the various plaque components, which can be partially offset by the use of multispectral analysis of multiple contrast images. With improvements in coil design, sequence design, and main field and gradient capabilities, accurate in vivo differentiation and measurement of these various carotid plaque components should be possible in 3 to 5 years. Ex vivo and in vivo studies have yielded high-resolution measurements of the complex three-dimensional lumen geometry, which are being used to predict hemodynamic forces acting on the lumenal surface. Carotid plaque burden can be accurately measured in vivo today; ongoing longitudinal studies should lead to a better understanding of the relationship between plaque burden and the risk of thromboembolic complications, as well as the effect of diet and drug therapy in hyperlipidemic patients. With these developments in place or soon to be available, MRI of the diseased carotid artery wall may prove to be even more important than magnetic resonance angiography.
Collapse
Affiliation(s)
- J K Demarco
- University Radiology Group, University of Medicine and Dentistry of New Jersey, Laurie Imaging Center, New Brunswick 08901, USA
| | | | | |
Collapse
|
39
|
Shunk KA, Atalar E, Lima JA. Possibilities of transesophageal MRI for assessment of aortic disease: a review. Int J Cardiovasc Imaging 2001; 17:179-85. [PMID: 11587451 DOI: 10.1023/a:1010667617641] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The thoracic aortic wall is a common site of atherosclerotic plaque in humans. Tools for serial, non-invasive assessment of these plaques are of value for addressing gaps in our basic understanding of the biology of plaque rupture and its relationship to atherosclerotic disease progression as well as for monitoring response to anti-atherosclerotic interventions in therapeutic clinical trials. Common approaches to assessment of the wall of the thoracic aorta in vivo are limited. Here we discuss some of the challenges and limitations encountered by conventional techniques and review a novel approach, transesophageal MRI (TEMRI). Initial experiences in applying the TEMRI approach to assessment of aortic morphology and pathology are discussed.
Collapse
Affiliation(s)
- K A Shunk
- Division of Cardiology, Johns Hopkins University, Baltimore, Maryland, USA.
| | | | | |
Collapse
|
40
|
Serfaty JM, Chaabane L, Tabib A, Chevallier JM, Briguet A, Douek PC. Atherosclerotic plaques: classification and characterization with T2-weighted high-spatial-resolution MR imaging-- an in vitro study. Radiology 2001; 219:403-10. [PMID: 11323464 DOI: 10.1148/radiology.219.2.r01ma15403] [Citation(s) in RCA: 88] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate if T2-weighted high-spatial-resolution magnetic resonance (MR) imaging (117 microm per pixel) can help accurate classification of atherosclerotic plaques. MATERIALS AND METHODS Thirty human arteries and 11 carotid endarterectomy specimens from 31 patients underwent T2-weighted MR imaging (2-T magnet; repetition time, 2,000 msec; echo time, 50 msec) at room temperature. After imaging, Bouin fixative was used to fix 26 arteries, and the other 15 arteries were fixed by means of freezing. Specimens were stained with hematoxylin-eosin and safranin or Sudan lipid stain. MR images and histologic slices were classified independently by two radiologists and a pathologist, respectively, on the basis of the American Heart Association classification. RESULTS Results with MR imaging were the following: type I-II plaques, sensitivity of 67% and specificity of 100%; type IV-Va plaques, sensitivity of 74% and specificity of 85%; type Vb plaques, sensitivity of 90% and specificity of 100%; type Vc plaques, sensitivity of 80% and specificity of 90%. No type III plaque was diagnosed in the study. The overall kappa value was 0.68. CONCLUSION High-spatial-resolution MR imaging with T2 weighting alone can help accurate classification of fibrocalcic plaques (type Vb), but it is subject to limitations for the classification and analysis of other types of atherosclerotic plaques.
Collapse
Affiliation(s)
- J M Serfaty
- Laboratoire de Résonance Magnétique Nuclèaire Unité Mixte de Recherche, Villeurbanne, France.
| | | | | | | | | | | |
Collapse
|
41
|
Yang X, Atalar E. Intravascular MR imaging-guided balloon angioplasty with an MR imaging guide wire: feasibility study in rabbits. Radiology 2000; 217:501-6. [PMID: 11058652 DOI: 10.1148/radiology.217.2.r00oc17501] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To develop a technique for intravascular magnetic resonance (MR)-guided balloon angioplasty with use of an MR imaging guide wire. MATERIALS AND METHODS An MR imaging guide wire (0.6-mm loopless antenna) that could be placed within a balloon catheter was manufactured. The guide wire was expected to function as either an MR receiver probe in real-time MR imaging or a guide wire for use with interventional devices. Laparotomy was performed in eight rabbits, and a dilatable stenosis was created at the upper abdominal aorta. Balloon angioplasty, validated at pre- and postoperative MR aortography with renal contrast enhancement was performed by using a 1.5-T MR unit with a fast spoiled gradient-echo pulse sequence, short repetition and echo times, and a rate of three frames per second. RESULTS During MR tracking, the entire length of the MR imaging guide wire was always visible as a band of high signal intensity. In all cases, the MR imaging guide wires were passed through the aortic stenoses dilated by means of balloon inflation. Before balloon angioplasty, flow in the aorta distal to the stenosis was decreased, which caused mild contrast enhancement in each kidney. After balloon angioplasty, distal flow was restored, resulting in substantial renal enhancement. CONCLUSION The MR imaging guide wire is a potential tool for use in endovascular interventional MR imaging.
Collapse
Affiliation(s)
- X Yang
- Department of Radiology, Johns Hopkins University School of Medicine, Outpatient Center Rm 4243, 601 N Caroline St, Baltimore MD 21287-0845, USA.
| | | |
Collapse
|
42
|
Serfaty JM, Atalar E, Declerck J, Karmakar P, Quick HH, Shunk KA, Heldman AW, Yang X. Real-time projection MR angiography: feasibility study. Radiology 2000; 217:290-5. [PMID: 11012459 DOI: 10.1148/radiology.217.1.r00se42290] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Intraarterial injections of small doses of gadopentetate dimeglumine were combined with a fast spoiled-gradient-echo magnetic resonance (MR) sequence to obtain real-time projection angiographic images of the rabbit aorta and canine coronary arteries. Arterial filling and washout, as well as venous and perfusion phases, were clearly displayed, demonstrating that arterial fluoroscopy in which an MR technique is used is feasible.
Collapse
Affiliation(s)
- J M Serfaty
- Departments of Radiology and Biomedical Engineering, Biomedical Engineering, Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Abstract
Several attributes make magnetic resonance imaging (MRI) attractive for guidance of intravascular therapeutic procedures, including high soft tissue contrast, imaging in arbitrary oblique planes, lack of ionizing radiation, and the ability to provide functional information, such as flow velocity or flow volume per unit time, in conjunction with morphologic information. For MR guidance of vascular interventions to be safe, the interventionalist must be able to visualize catheters and guidewires relative to the vascular system and surrounding tissues. A number of approaches for rendering instruments visible in an MR environment have been developed, including both passive and active techniques. Passive techniques depend on contrast agents or susceptibility artifacts that enhance the appearance of the catheter in the image itself, whereas active techniques rely on supplemental hardware built into the catheter, such as a radiofrequency (RF) coil. Additionally, the ability to introduce an RF coil mounted on a catheter presents the opportunity to obtain high-resolution images of the vessel wall. These images can provide the capability to distinguish and identify various plaque components. The additional capabilities of MRI could potentially open up new applications within the purview of vascular interventions beyond those currently performed under X-ray fluoroscopic guidance.
Collapse
Affiliation(s)
- M E Ladd
- Department of Radiology, University Hospital Essen, D-45122 Essen, Germany.
| | | | | |
Collapse
|
44
|
Christov A, Dai E, Drangova M, Liu L, Abela GS, Nash P, McFadden G, Lucas A. Optical detection of triggered atherosclerotic plaque disruption by fluorescence emission analysis. Photochem Photobiol 2000; 72:242-52. [PMID: 10946579 DOI: 10.1562/0031-8655(2000)072<0242:odotap>2.0.co;2] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Fluorescence emission analysis (FEA) has proven to be very sensitive for the detection of elastin, collagen and lipids, which are recognized as the major sources of autofluorescence in vascular tissues. FEA has also been reported to detect venous thromboemboli. In this paper we have tested the hypothesis that FEA can reproducibly detect in vivo and in vitro triggered plaque disruption and thrombosis in a rabbit model. Fluorescence emission (FE) spectra, recorded in vivo, detected Russell's viper venom (RVV)-induced transformation of atherosclerotic plaque. FE intensity at 410-490 nm 4 weeks after angioplasty was significantly lower (P < 0.0033 by analysis of variance) in RVV-treated rabbits when compared to control animals with stable plaque. FE spectral profile analyses also demonstrated a significant change in curve shape as demonstrated by polynomial regression analysis (R2 from 0.980 to 0.997). We have also demonstrated an excellent correlation between changes in FE intensity and the structural characteristics detected at different stages of "unstable atherosclerotic plaque" development using multiple regression analysis (R2 = 0.989). Thus, FEA applied in vivo is a sensitive and highly informative diagnostic technique for detection of triggered atherosclerotic plaque disruption and related structural changes, associated with plaque transformation, in a rabbit model.
Collapse
Affiliation(s)
- A Christov
- Vascular Biology Research Labs, John P. Robart's Research Institute, London, Ontario, Canada
| | | | | | | | | | | | | | | |
Collapse
|
45
|
Pasterkamp G, Falk E, Woutman H, Borst C. Techniques characterizing the coronary atherosclerotic plaque: influence on clinical decision making? J Am Coll Cardiol 2000; 36:13-21. [PMID: 10898406 DOI: 10.1016/s0735-1097(00)00677-x] [Citation(s) in RCA: 119] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The composition of the atherosclerotic lesion rather than the degree of stenosis is currently considered to be the most important determinant for acute clinical events. Modalities capable of characterizing the atherosclerotic lesion may be helpful in understanding its natural history and detecting lesions with high risk for acute events. Speaking grossly, three histologic features of the vulnerable plaque have been reported: size of the atheroma, thickness of the fibrous cap, and inflammation. Imaging techniques are currently being deployed and are under development to aid visualization of the vulnerable coronary plaque. Most of these diagnostic modalities have the potential to detect locally one or more of the three histologically defined features of vulnerable plaque. This review will focus on imaging techniques that have been developed to characterize the atherosclerotic lesion. Most catheter-based visualization techniques will provide insight into components of the local atherosclerotic plaque which may limit their predictive value for the occurrence of a clinical event. Therefore, the clinical relevance of these imaging tools will be discussed.
Collapse
Affiliation(s)
- G Pasterkamp
- Experimental Cardiology Laboratory, University Medical Center, Utrecht.
| | | | | | | |
Collapse
|
46
|
Christov A, Dai E, Liu L, Miller LW, Nash P, Lalani A, McFadden G, Nation PN, Tulip J, Lucas A. Detection of transplant vasculopathy in a rat aortic allograft model by fluorescence spectroscopic optical analysis. Lasers Surg Med 2000; 24:346-59. [PMID: 10406475 DOI: 10.1002/(sici)1096-9101(1999)24:5<346::aid-lsm5>3.0.co;2-k] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND AND OBJECTIVE Transplant vasculopathy is a leading cause of late cardiac graft loss. We have examined laser-induced fluorescence (LIF) spectroscopy as an optical diagnostic tool for detection of intimal plaque development and inflammatory cellular invasion in a rat model of aortic allograft transplant. STUDY DESIGN/MATERIALS AND METHODS Infrarenal aortic segments were transplanted from Lewis to Sprague Dawley rats. A range of vasculopathy development was produced by treatment with a viral anti-inflammatory protein. LIF spectra were recorded from the intima of aortic implants at 28 days. Fluorescence intensity was analyzed for correlation with vasculopathy development. RESULTS Significant differences in LIF intensity at 400-450 nm (P < or = 0.05 by ANOVA) were detected. LIF emission was correlated with plaque growth (R2 = 0.980), vessel narrowing (R2 = 0.964), and cellular invasion (R2 = 0.971) by regression analysis. CONCLUSION LIF optical analysis provides a nontraumatic diagnostic approach for detection of atherosclerosis prior to cardiac transplant or during development of vasculopathy after transplant.
Collapse
Affiliation(s)
- A Christov
- Vascular Biology Group, John P. Robarts Research Institute, University of Western Ontario, London, Canada
| | | | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Detrano RC, Doherty TM, Davies MJ, Stary HC. Predicting coronary events with coronary calcium: pathophysiologic and clinical problems. Curr Probl Cardiol 2000; 25:374-402. [PMID: 10849509 DOI: 10.1067/mcd.2000.104848] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
- R C Detrano
- Division of Cardiology, Department of Medicine Harbor-UCLA Medical Center St. John's Cardiovascular Research Center Torrance, California, USA
| | | | | | | |
Collapse
|
48
|
Abstract
The purpose of this study was to develop a non-invasive method of imaging the thoracic aorta that would provide both morphological detail within the aortic wall and information about regional aortic wall motion. An esophageal probe is described that allows transesophageal MR imaging (TEMRI) of the thoracic aorta and has several potential advantages over the competing non-vasculoinvasive techniques of transesophageal echocardiography (TEE) or standard MRI. The probe consists of a loopless antenna housed inside a modified Levin gastric tube, with external matching and tuning circuitry. Using this probe, the thoracic aorta has been imaged in longitudinal and cross-sectional views. Details of the aortic wall were readily seen. Tissue tagging for measurement of focal stress/strain relationships was demonstrated to be feasible. TEMRI avoids the risks inherent in intravascular MRI yet provides comparable image quality. Potential applications of the device are discussed.
Collapse
Affiliation(s)
- K A Shunk
- Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland 21287-0845, USA
| | | | | | | |
Collapse
|
49
|
Atalar E, Kraitchman DL, Carkhuff B, Lesho J, Ocali O, Solaiyappan M, Guttman MA, Charles HK. Catheter-tracking FOV MR fluoroscopy. Magn Reson Med 1998; 40:865-72. [PMID: 9840831 DOI: 10.1002/mrm.1910400612] [Citation(s) in RCA: 63] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Recent improvements in intravascular magnetic resonance imaging techniques mandate an accurate method of monitoring the introduction of MR catheter probes into the vessel of interest. For this purpose, a novel imaging protocol and a display method have been designed. First, a roadmap 3D image data set with standard pulse sequences is obtained using an external imaging coil. Subsequently, using very narrow rectangular-FOV fast-spoiled gradient recalled (SPGR), a movie of the percutaneous placement procedure of an MR catheter probe is acquired at a rate of 7.3 frames/second. In this protocol, the probe is used to transmit RF pulses and receive MR signal. A computer program was written for image unwrapping and for displaying the unwrapped movie frames on the roadmap image. In an alternative protocol, the movie frames in two projection angles were acquired in an interleaved fashion. Frames were unwrapped and combined with a 3D roadmap and displayed on a Silicon Graphics workstation equipped with stereovision goggles. Using these methods, percutaneous catheter placement in a phantom and a dog was examined. In conclusion, a new visualization technique for MR catheter placement is proposed. Combining this technique with high resolution intravascular MRI techniques may result in a very useful diagnostic tool for the evaluation of atherosclerosis and other vessel diseases.
Collapse
Affiliation(s)
- E Atalar
- Department of Radiology, Johns Hopkins University, Baltimore, MD 21287-0845, USA
| | | | | | | | | | | | | | | |
Collapse
|
50
|
Yang X, Bolster BD, Kraitchman DL, Atalar E. Intravascular MR-monitored balloon angioplasty: an in vivo feasibility study. J Vasc Interv Radiol 1998; 9:953-9. [PMID: 9840040 DOI: 10.1016/s1051-0443(98)70429-4] [Citation(s) in RCA: 52] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Abstract
PURPOSE To develop a new method for monitoring balloon angioplasty by using an intravascular magnetic resonance (MR) imaging technique. MATERIALS AND METHODS Nine New Zealand White rabbits were used: seven for technique refinement, including surgery, device insertion, stenosis creation, and MR protocol development; and two for the final MR imaging of the balloon angioplasty. The in vivo experimental method involved insertion of a catheter antenna and a balloon catheter, via femoral arteriotomies bilaterally, into the target site of the upper abdominal aorta, where a stenosis was artificially created by binding a plastic cable tie. Then, the entire process of the dilation of the stenosis with balloon inflation was monitored under MR fluoroscopy. RESULTS Catheter insertions were successful, and a 5-mm-long stenosis of the aorta was produced in all nine rabbits. Eight complete balloon angioplasty procedures were satisfactorily monitored and recorded, showing clearly the stenosis of the aorta at the beginning of the procedure, the dilation of the stenosis during the balloon inflation, and the complete opening of the stenosis after balloon dilation. CONCLUSION Preliminary results of in vivo balloon angioplasty monitored with intravascular MR imaging are presented. MR fluoroscopy, based on the intravascular MR imaging technique, may represent a potential alternative to x-ray fluoroscopy for guiding interventional treatment of cardiovascular diseases.
Collapse
Affiliation(s)
- X Yang
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD 21287-0845, USA
| | | | | | | |
Collapse
|