1
|
Schlattmann P, Wieske V, Bressem KK, Götz T, Schuetz GM, Andreini D, Pontone G, Alkadhi H, Hausleiter J, Zimmermann E, Gerber B, Shabestari AA, Meijs MFL, Sato A, Øvrehus KA, Jenkins SMM, Knuuti J, Hamdan A, Halvorsen BA, Mendoza-Rodriguez V, Rixe J, Wan YL, Langer C, Leschka S, Martuscelli E, Ghostine S, Tardif JC, Sánchez AR, Haase R, Dewey M. The effectiveness of coronary computed tomography angiography and functional testing for the diagnosis of obstructive coronary artery disease: results from the individual patient data Collaborative Meta-Analysis of Cardiac CT (COME-CCT). Insights Imaging 2024; 15:208. [PMID: 39143443 PMCID: PMC11324632 DOI: 10.1186/s13244-024-01702-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 11/01/2023] [Indexed: 08/16/2024] Open
Abstract
AIM To determine the effectiveness of functional stress testing and computed tomography angiography (CTA) for diagnosis of obstructive coronary artery disease (CAD). METHODS AND RESULTS Two-thousand nine-hundred twenty symptomatic stable chest pain patients were included in the international Collaborative Meta-Analysis of Cardiac CT consortium to compare CTA with exercise electrocardiography (exercise-ECG) and single-photon emission computed tomography (SPECT) for diagnosis of CAD defined as ≥ 50% diameter stenosis by invasive coronary angiography (ICA) as reference standard. Generalised linear mixed models were used for calculating the diagnostic accuracy of each diagnostic test including non-diagnostic results as dependent variables in a logistic regression model with random intercepts and slopes. Covariates were the reference standard ICA, the type of diagnostic method, and their interactions. CTA showed significantly better diagnostic performance (p < 0.0001) with a sensitivity of 94.6% (95% CI 92.7-96) and a specificity of 76.3% (72.2-80) compared to exercise-ECG with 54.9% (47.9-61.7) and 60.9% (53.4-66.3), SPECT with 72.9% (65-79.6) and 44.9% (36.8-53.4), respectively. The positive predictive value of CTA was ≥ 50% in patients with a clinical pretest probability of 10% or more while this was the case for ECG and SPECT at pretest probabilities of ≥ 40 and 28%. CTA reliably excluded obstructive CAD with a post-test probability of below 15% in patients with a pretest probability of up to 74%. CONCLUSION In patients with stable chest pain, CTA is more effective than functional testing for the diagnosis as well as for reliable exclusion of obstructive CAD. CTA should become widely adopted in patients with intermediate pretest probability. SYSTEMATIC REVIEW REGISTRATION PROSPERO Database for Systematic Reviews-CRD42012002780. CRITICAL RELEVANCE STATEMENT In symptomatic stable chest pain patients, coronary CTA is more effective than functional testing for diagnosis and reliable exclusion of obstructive CAD in intermediate pretest probability of CAD. KEY POINTS Coronary computed tomography angiography showed significantly better diagnostic performance (p < 0.0001) for diagnosis of coronary artery disease compared to exercise-ECG and SPECT. The positive predictive value of coronary computed tomography angiography was ≥ 50% in patients with a clinical pretest probability of at least 10%, for ECG ≥ 40%, and for SPECT 28%. Coronary computed tomography angiography reliably excluded obstructive coronary artery disease with a post-test probability of below 15% in patients with a pretest probability of up to 74%.
Collapse
Affiliation(s)
- Peter Schlattmann
- Institute of Medical Statistics, Computer Sciences, and Data Science, University Hospital of Friedrich Schiller University Jena, Jena, Germany
| | - Viktoria Wieske
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Keno K Bressem
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Theresa Götz
- Institute of Medical Statistics, Computer Sciences, and Data Science, University Hospital of Friedrich Schiller University Jena, Jena, Germany
| | - Georg M Schuetz
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | | | | | - Hatem Alkadhi
- Institute of Diagnostic and Interventional Radiology University Hospital Zurich, Zurich, Switzerland
| | | | - Elke Zimmermann
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Bernhard Gerber
- Department of Cardiology, Clinique Universitaire St Luc, Institut de Recherche Clinique et Expérimentale, Brussels, Belgium
| | - Abbas A Shabestari
- Modarres Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Matthijs F L Meijs
- Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Akira Sato
- Cardiovascular Division, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan
| | | | | | - Juhani Knuuti
- Turku University Hospital and University of Turku, Turku, Finland
| | - Ashraf Hamdan
- Department of Cardiovascular Imaging, Department of Cardiology, Rabin Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel
| | | | | | - Johannes Rixe
- Department of Cardiology and Electrophysiology, Jung Stilling Hospital Siegen, Siegen, Germany
| | - Yung-Liang Wan
- Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Chang Gung Memorial Hospital at Linkou, Taoyaun City, Taiwan
| | - Christoph Langer
- Kardiologisch-Angiologische Praxis, Herzzentrum Bremen, Bremen, Germany
| | - Sebastian Leschka
- Department of Radiology, Kantonsspital St Gallen, St Gallen, Switzerland
| | - Eugenio Martuscelli
- Department of Internal Medicine, University of Rome Tor Vergata, Rome, Italy
| | - Said Ghostine
- Department of Cardiology, Centre Chirurgical Marie Lannelongue, Le Plessis Robinson, France
| | | | | | - Robert Haase
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Marc Dewey
- Department of Radiology, Charité-Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany.
- Berlin Institute of Health, Berlin, Germany.
- DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
| |
Collapse
|
2
|
Henriques J, Amaro AM, Piedade AP. Biomimicking Atherosclerotic Vessels: A Relevant and (Yet) Sub-Explored Topic. Biomimetics (Basel) 2024; 9:135. [PMID: 38534820 DOI: 10.3390/biomimetics9030135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 02/20/2024] [Accepted: 02/21/2024] [Indexed: 03/28/2024] Open
Abstract
Atherosclerosis represents the etiologic source of several cardiovascular events, including myocardial infarction, cerebrovascular accidents, and peripheral artery disease, which remain the leading cause of mortality in the world. Numerous strategies are being delineated to revert the non-optimal projections of the World Health Organization, by both designing new diagnostic and therapeutic approaches or improving the interventional procedures performed by physicians. Deeply understanding the pathological process of atherosclerosis is, therefore, mandatory to accomplish improved results in these trials. Due to their availability, reproducibility, low expensiveness, and rapid production, biomimicking physical models are preferred over animal experimentation because they can overcome some limitations, mainly related to replicability and ethical issues. Their capability to represent any atherosclerotic stage and/or plaque type makes them valuable tools to investigate hemodynamical, pharmacodynamical, and biomechanical behaviors, as well as to optimize imaging systems and, thus, obtain meaningful prospects to improve the efficacy and effectiveness of treatment on a patient-specific basis. However, the broadness of possible applications in which these biomodels can be used is associated with a wide range of tissue-mimicking materials that are selected depending on the final purpose of the model and, consequently, prioritizing some materials' properties over others. This review aims to summarize the progress in fabricating biomimicking atherosclerotic models, mainly focusing on using materials according to the intended application.
Collapse
Affiliation(s)
- Joana Henriques
- University of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, 3030-788 Coimbra, Portugal
| | - Ana M Amaro
- University of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, 3030-788 Coimbra, Portugal
| | - Ana P Piedade
- University of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, 3030-788 Coimbra, Portugal
| |
Collapse
|
3
|
Palicherla A, Ismayl M, Thandra A, Budoff M, Shaikh K. Evaluation of stable angina by coronary computed tomographic angiography versus standard of care: A systematic review and meta-analysis. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2024; 59:67-75. [PMID: 37541837 DOI: 10.1016/j.carrev.2023.07.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 07/25/2023] [Accepted: 07/25/2023] [Indexed: 08/06/2023]
Abstract
INTRODUCTION There is limited data comparing Coronary Computed Tomography Angiography (CCTA) versus the usual Standard of care (SOC) in patients with suspected stable coronary artery disease (CAD). We aimed to perform a systematic review and meta-analysis to compare CCTA versus SOC in patients with stable CAD. METHODS We searched multiple databases for randomized controlled trials (RCTs) comparing CCTA with SOC, which included various functional testing approaches for evaluating stable CAD. We used a random-effects model to calculate risk ratios (RRs) with 95 % confidence intervals (CIs). Outcomes included all-cause mortality, myocardial infarction (MI), hospitalization for unstable angina (UA), invasive angiography, revascularization, percutaneous coronary intervention (PCI), and coronary artery bypass grafting (CABG). RESULTS We identified 6 RCTs with 19,881 patients with stable CAD, of which 9995 underwent CCTA, and 9886 underwent SOC. There were no significant differences between CCTA and SOC in terms of all-cause mortality (RR: 0.91; 95 % CI: 0.70-1.19; p = 0.50), MI (RR: 0.78; 95 % CI: 0.58-1.05; p = 0.11), hospitalizations for UA (RR: 1.20; 95 % CI: 0.95-1.51;p = 0.12), invasive angiography (RR: 0.71; 95 % CI: 0.32-1.61; p = 0.42), revascularization (RR:1.25; 95 % CI: 0.83-1.89; p = 0.29), PCI (RR: 1.20; 95 % CI: 0.78-1.85; p = 0.40), and CABG rates (RR: 0.89; 95 % CI: 0.530-1.49; p = 0.65). CONCLUSION In patients with stable CAD, CCTA is associated with similar outcomes compared to the usual Standard of care. Given its potential to quickly rule out severe obstructive disease, its ability to provide non-invasive physiology and identify non-obstructive CAD with plaque information makes it an attractive addition to the available armamentarium to evaluate chest pain.
Collapse
Affiliation(s)
- Anirudh Palicherla
- Internal Medicine, Creighton University School of Medicine, Omaha, NE, United States of America.
| | - Mahmoud Ismayl
- Internal Medicine, Creighton University School of Medicine, Omaha, NE, United States of America
| | - Abhishek Thandra
- Interventional Cardiology, Creighton University School of Medicine, Omaha, NE, United States of America.
| | - Matthew Budoff
- David Geffen School of Medicine at UCLA, Los Angeles, United States of America.
| | - Kashif Shaikh
- University of Tennessee, Knoxville, United States of America
| |
Collapse
|
4
|
Tatsugami F, Higaki T, Kawashita I, Fukumoto W, Nakamura Y, Matsuura M, Lee TC, Zhou J, Cai L, Kitagawa T, Nakano Y, Awai K. Improvement of Spatial Resolution on Coronary CT Angiography by Using Super-Resolution Deep Learning Reconstruction. Acad Radiol 2023; 30:2497-2504. [PMID: 36681533 DOI: 10.1016/j.acra.2022.12.044] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 12/27/2022] [Accepted: 12/28/2022] [Indexed: 01/21/2023]
Abstract
RATIONALE AND OBJECTIVES Our objective was to compare the image quality of coronary CT angiography reconstructed with super-resolution deep learning reconstruction (SR-DLR) and with hybrid iterative reconstruction (IR) images. MATERIALS AND METHODS This retrospective study included 100 patients who underwent coronary CT angiography using a 320-detector-row CT scanner. The CT images were reconstructed with hybrid IR and SR-DLR. The standard deviation of the CT number was recorded and the CT attenuation profile across the left main coronary artery was generated to calculate the contrast-to-noise ratio (CNR) and measure the edge rise slope (ERS). Overall image quality was evaluated and plaque detectability was assessed on a 4-point scale (1 = poor, 4 = excellent). For reference, invasive coronary angiography of 14 patients was used. RESULTS The mean image noise on SR-DLR was significantly lower than on hybrid IR images (15.6 vs 22.9 HU; p < 0.01). The mean CNR was significantly higher and the ERS was steeper on SR-DLR- compared to hybrid IR images (CNR: 32.4 vs 20.4, p < 0.01; ERS: 300.0 vs 198.2 HU/mm, p < 0.01). The image quality score was better on SR-DLR- than on hybrid IR images (3.6 vs 3.1; p < 0.01). SR-DLR increased the detectability of plaques with < 50% stenosis (p < 0.01). CONCLUSION SR-DLR was superior to hybrid IR with respect to the image noise, the sharpness of coronary artery margins, and plaque detectability.
Collapse
Affiliation(s)
- Fuminari Tatsugami
- Department of Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima City, Hiroshima, 734-8551, Japan.
| | - Toru Higaki
- Graduate School of Advanced Science and Engineering, Hiroshima University, Higashi-Hiroshima City, Hiroshima, Japan
| | - Ikuo Kawashita
- Department of Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima City, Hiroshima, 734-8551, Japan
| | - Wataru Fukumoto
- Department of Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima City, Hiroshima, 734-8551, Japan
| | - Yuko Nakamura
- Department of Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima City, Hiroshima, 734-8551, Japan
| | | | | | - Jian Zhou
- Canon Medical Research USA, Vernon Hills, Illinois
| | - Liang Cai
- Canon Medical Research USA, Vernon Hills, Illinois
| | - Toshiro Kitagawa
- Department of Cardiovascular Medicine, Hiroshima University, Hiroshima City, Hiroshima, Japan
| | - Yukiko Nakano
- Department of Cardiovascular Medicine, Hiroshima University, Hiroshima City, Hiroshima, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima City, Hiroshima, 734-8551, Japan
| |
Collapse
|
5
|
Mézquita AJV, Biavati F, Falk V, Alkadhi H, Hajhosseiny R, Maurovich-Horvat P, Manka R, Kozerke S, Stuber M, Derlin T, Channon KM, Išgum I, Coenen A, Foellmer B, Dey D, Volleberg RHJA, Meinel FG, Dweck MR, Piek JJ, van de Hoef T, Landmesser U, Guagliumi G, Giannopoulos AA, Botnar RM, Khamis R, Williams MC, Newby DE, Dewey M. Clinical quantitative coronary artery stenosis and coronary atherosclerosis imaging: a Consensus Statement from the Quantitative Cardiovascular Imaging Study Group. Nat Rev Cardiol 2023; 20:696-714. [PMID: 37277608 DOI: 10.1038/s41569-023-00880-4] [Citation(s) in RCA: 42] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/19/2023] [Indexed: 06/07/2023]
Abstract
The detection and characterization of coronary artery stenosis and atherosclerosis using imaging tools are key for clinical decision-making in patients with known or suspected coronary artery disease. In this regard, imaging-based quantification can be improved by choosing the most appropriate imaging modality for diagnosis, treatment and procedural planning. In this Consensus Statement, we provide clinical consensus recommendations on the optimal use of different imaging techniques in various patient populations and describe the advances in imaging technology. Clinical consensus recommendations on the appropriateness of each imaging technique for direct coronary artery visualization were derived through a three-step, real-time Delphi process that took place before, during and after the Second International Quantitative Cardiovascular Imaging Meeting in September 2022. According to the Delphi survey answers, CT is the method of choice to rule out obstructive stenosis in patients with an intermediate pre-test probability of coronary artery disease and enables quantitative assessment of coronary plaque with respect to dimensions, composition, location and related risk of future cardiovascular events, whereas MRI facilitates the visualization of coronary plaque and can be used in experienced centres as a radiation-free, second-line option for non-invasive coronary angiography. PET has the greatest potential for quantifying inflammation in coronary plaque but SPECT currently has a limited role in clinical coronary artery stenosis and atherosclerosis imaging. Invasive coronary angiography is the reference standard for stenosis assessment but cannot characterize coronary plaques. Finally, intravascular ultrasonography and optical coherence tomography are the most important invasive imaging modalities for the identification of plaques at high risk of rupture. The recommendations made in this Consensus Statement will help clinicians to choose the most appropriate imaging modality on the basis of the specific clinical scenario, individual patient characteristics and the availability of each imaging modality.
Collapse
Affiliation(s)
| | - Federico Biavati
- Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Volkmar Falk
- Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Charité - Universitätsmedizin Berlin, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research) Partner Site, Berlin, Germany
- Department of Health Science and Technology, ETH Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Reza Hajhosseiny
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- National Heart and Lung Institute, Imperial College London, London, UK
| | - Pál Maurovich-Horvat
- Department of Radiology, Medical Imaging Center, Semmelweis University, Budapest, Hungary
| | - Robert Manka
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, ETH Zurich, University of Zurich, Zurich, Switzerland
| | - Matthias Stuber
- Department of Radiology, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | - Thorsten Derlin
- Department of Nuclear Medicine, Hannover Medical School, Hannover, Germany
| | - Keith M Channon
- Radcliffe Department of Medicine, University of Oxford and Oxford University Hospitals, Oxford, UK
| | - Ivana Išgum
- Department of Biomedical Engineering and Physics, Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Adriaan Coenen
- Department of Radiology, Erasmus University, Rotterdam, Netherlands
| | - Bernhard Foellmer
- Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Damini Dey
- Departments of Biomedical Sciences and Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Rick H J A Volleberg
- Department of Cardiology, Radboud University Medical Center, Nijmegen, Netherlands
| | - Felix G Meinel
- Department of Radiology, University Medical Centre Rostock, Rostock, Germany
| | - Marc R Dweck
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | - Jan J Piek
- Department of Clinical and Experimental Cardiology and Cardiovascular Sciences, Amsterdam UMC, Heart Center, University of Amsterdam, Amsterdam, Netherlands
| | - Tim van de Hoef
- Department of Cardiology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Ulf Landmesser
- DZHK (German Centre for Cardiovascular Research) Partner Site, Berlin, Germany
- Department of Cardiology, Deutsches Herzzentrum der Charité (DHZC), Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Giulio Guagliumi
- Division of Cardiology, IRCCS Galeazzi Sant'Ambrogio Hospital, Milan, Italy
| | - Andreas A Giannopoulos
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - René M Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile
| | - Ramzi Khamis
- National Heart and Lung Institute, Imperial College London, London, UK
| | | | - David E Newby
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | - Marc Dewey
- Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany.
- DZHK (German Centre for Cardiovascular Research) Partner Site, Berlin, Germany.
- Deutsches Herzzentrum der Charité (DHZC), Charité - Universitätsmedizin Berlin, Berlin, Germany.
- Berlin Institute of Health, Campus Charité Mitte, Berlin, Germany.
| |
Collapse
|
6
|
Waldeck S, Overhoff D, Brockmann MA, Becker BV. Detection of Endoleaks Following Thoracic and Abdominal Aortic Endovascular Aortic Repair-: A Comparison of Standard and Dynamic 4D-Computed Tomography Angiography. J Endovasc Ther 2023; 30:739-745. [PMID: 35582987 DOI: 10.1177/15266028221095390] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE Endoleaks are a common complication after endovascular aortic repair (EVAR) and thoracic endovascular aortic repair (TEVAR). The detection and correct classification of endoleaks is essential for the further treatment of affected patients. However, standard computed tomography angiography (CTA) provides no hemodynamic information on endoleaks, which can result in misclassification in complex cases. The aim of this study was to compare standard CTA (sCTA) with dynamic, dual-energy CTA (dCTA) for detection and classification of endoleaks following EVAR or TEVAR. MATERIALS AND METHODS This retrospective evaluation compared 69 sCTA diagnostic examinations performed on 50 different patients with 89 dCTA diagnostic examinations performed on 69 different patients. RESULTS In total, 15.9% of sCTA examinations and 49.4% of dCTA examinations led to the detection of endoleaks. With sCTA, 20.0% of patients were diagnosed with endoleaks, while with dCTA, 37.7% of patients were diagnosed with endoleaks. With sCTA, mainly Type 1 endoleaks were detected, whereas, with dCTA, the types of detected endoleaks were more evenly distributed. In comparison with the literature, the frequencies of endoleak types detected with dCTA better reflect the natural distribution than the frequencies detected with standard CTA. CONCLUSION Based on the retrospective comparative evaluation, dCTA could pose a valuable supplementary diagnostic tool resulting in a more accurate and realistic detection and classification of suspected endoleaks.
Collapse
Affiliation(s)
- Stephan Waldeck
- Department of Diagnostic and Interventional Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz, Germany
- Institute of Neuroradiology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Daniel Overhoff
- Department of Diagnostic and Interventional Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz, Germany
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Marc A Brockmann
- Institute of Neuroradiology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Benjamin V Becker
- Department of Diagnostic and Interventional Radiology and Neuroradiology, Bundeswehr Central Hospital Koblenz, Koblenz, Germany
- Institute of Neuroradiology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany
| |
Collapse
|
7
|
Takafuji M, Kitagawa K, Mizutani S, Hamaguchi A, Kisou R, Iio K, Ichikawa K, Izumi D, Sakuma H. Super-Resolution Deep Learning Reconstruction for Improved Image Quality of Coronary CT Angiography. Radiol Cardiothorac Imaging 2023; 5:e230085. [PMID: 37693207 PMCID: PMC10485715 DOI: 10.1148/ryct.230085] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 05/29/2023] [Accepted: 06/20/2023] [Indexed: 09/12/2023]
Abstract
Purpose To investigate image noise and edge sharpness of coronary CT angiography (CCTA) with super-resolution deep learning reconstruction (SR-DLR) compared with conventional DLR (C-DLR) and to evaluate agreement in stenosis grading using CCTA with that from invasive coronary angiography (ICA) as the reference standard. Materials and Methods This retrospective study included 58 patients (mean age, 69.0 years ± 12.8 [SD]; 38 men, 20 women) who underwent CCTA using 320-row CT between April and September 2022. All images were reconstructed with two different algorithms: SR-DLR and C-DLR. Image noise, signal-to-noise ratio, edge sharpness, full width at half maximum (FWHM) of stent, and agreement in stenosis grading with that from ICA were compared. Stenosis was visually graded from 0 to 5, with 5 indicating occlusion. Results SR-DLR significantly decreased image noise by 31% compared with C-DLR (12.6 HU ± 2.3 vs 18.2 HU ± 1.9; P < .001). Signal-to-noise ratio and edge sharpness were significantly improved by SR-DLR compared with C-DLR (signal-to-noise ratio, 38.7 ± 8.3 vs 26.2 ± 4.6; P < .001; edge sharpness, 560 HU/mm ± 191 vs 463 HU/mm ± 164; P < .001). The FWHM of stent was significantly thinner on SR-DLR (0.72 mm ± 0.22) than on C-DLR (1.01 mm ± 0.21; P < .001). Agreement in stenosis grading between CCTA and ICA was improved on SR-DLR compared with C-DLR (weighted κ = 0.83 vs 0.77). Conclusion SR-DLR improved vessel sharpness, image noise, and accuracy of coronary stenosis grading compared with the C-DLR technique.Keywords: CT Angiography, Cardiac, Coronary Arteries Supplemental material is available for this article. © RSNA, 2023.
Collapse
Affiliation(s)
- Masafumi Takafuji
- From the Department of Radiology, Mie University Graduate School of
Medicine, 2-174 Edobashi, Tsu 514-8507, Japan (M.T., K.K., H.S.); and
Departments of Radiology (M.T., S.M., A.H., R.K.) and Cardiology (K. Iio, K.
Ichikawa, D.I.), Matsusaka Municipal Hospital, Matsusaka, Japan
| | - Kakuya Kitagawa
- From the Department of Radiology, Mie University Graduate School of
Medicine, 2-174 Edobashi, Tsu 514-8507, Japan (M.T., K.K., H.S.); and
Departments of Radiology (M.T., S.M., A.H., R.K.) and Cardiology (K. Iio, K.
Ichikawa, D.I.), Matsusaka Municipal Hospital, Matsusaka, Japan
| | - Sachio Mizutani
- From the Department of Radiology, Mie University Graduate School of
Medicine, 2-174 Edobashi, Tsu 514-8507, Japan (M.T., K.K., H.S.); and
Departments of Radiology (M.T., S.M., A.H., R.K.) and Cardiology (K. Iio, K.
Ichikawa, D.I.), Matsusaka Municipal Hospital, Matsusaka, Japan
| | - Akane Hamaguchi
- From the Department of Radiology, Mie University Graduate School of
Medicine, 2-174 Edobashi, Tsu 514-8507, Japan (M.T., K.K., H.S.); and
Departments of Radiology (M.T., S.M., A.H., R.K.) and Cardiology (K. Iio, K.
Ichikawa, D.I.), Matsusaka Municipal Hospital, Matsusaka, Japan
| | - Ryosuke Kisou
- From the Department of Radiology, Mie University Graduate School of
Medicine, 2-174 Edobashi, Tsu 514-8507, Japan (M.T., K.K., H.S.); and
Departments of Radiology (M.T., S.M., A.H., R.K.) and Cardiology (K. Iio, K.
Ichikawa, D.I.), Matsusaka Municipal Hospital, Matsusaka, Japan
| | - Kotaro Iio
- From the Department of Radiology, Mie University Graduate School of
Medicine, 2-174 Edobashi, Tsu 514-8507, Japan (M.T., K.K., H.S.); and
Departments of Radiology (M.T., S.M., A.H., R.K.) and Cardiology (K. Iio, K.
Ichikawa, D.I.), Matsusaka Municipal Hospital, Matsusaka, Japan
| | - Kazuhide Ichikawa
- From the Department of Radiology, Mie University Graduate School of
Medicine, 2-174 Edobashi, Tsu 514-8507, Japan (M.T., K.K., H.S.); and
Departments of Radiology (M.T., S.M., A.H., R.K.) and Cardiology (K. Iio, K.
Ichikawa, D.I.), Matsusaka Municipal Hospital, Matsusaka, Japan
| | - Daisuke Izumi
- From the Department of Radiology, Mie University Graduate School of
Medicine, 2-174 Edobashi, Tsu 514-8507, Japan (M.T., K.K., H.S.); and
Departments of Radiology (M.T., S.M., A.H., R.K.) and Cardiology (K. Iio, K.
Ichikawa, D.I.), Matsusaka Municipal Hospital, Matsusaka, Japan
| | - Hajime Sakuma
- From the Department of Radiology, Mie University Graduate School of
Medicine, 2-174 Edobashi, Tsu 514-8507, Japan (M.T., K.K., H.S.); and
Departments of Radiology (M.T., S.M., A.H., R.K.) and Cardiology (K. Iio, K.
Ichikawa, D.I.), Matsusaka Municipal Hospital, Matsusaka, Japan
| |
Collapse
|
8
|
Pang K, Pan D, Xu H, Ma Y, Wang J, Xu P, Wang H, Zang G. Advances in physical diagnosis and treatment of male erectile dysfunction. Front Physiol 2023; 13:1096741. [PMID: 36699684 PMCID: PMC9868413 DOI: 10.3389/fphys.2022.1096741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 12/28/2022] [Indexed: 01/10/2023] Open
Abstract
Erectile dysfunction (ED) is the most common male sexual dysfunction by far and the prevalence is increasing year after year. As technology advances, a wide range of physical diagnosis tools and therapeutic approaches have been developed for ED. At present, typical diagnostic devices include erection basic parameter measuring instrument, erection hardness quantitative analysis system, hemodynamic testing equipment, nocturnal erection measuring instrument, nerve conduction testing equipment, etc. At present, the most commonly used treatment for ED is pharmacological therapy represented by phosphodiesterase five inhibitors (PDE5i). As a first-line drug in clinical, PDE5i has outstanding clinical effects, but there are still some problems that deserve the attention of researchers, such as cost issues and some side effects, like visual disturbances, indigestion, myalgia, and back pain, as well as some non-response rates. Some patients have to consider alternative treatments. Moreover, the efficacy in some angiogenic EDs (diabetes and cardiovascular disease) has not met expectations, so there is still a need to continuously develop new methods that can improve hemodynamics. While drug have now been shown to be effective in treating ED, they only control symptoms and do not restore function in most cases. The increasing prevalence of ED also makes us more motivated to find safer, more effective, and simpler treatments. The exploration of relevant mechanisms can also serve as a springboard for the development of more clinically meaningful physiotherapy approaches. Therefore, people are currently devoted to studying the effects of physical therapy and physical therapy combined with drug therapy on ED. We reviewed the diagnosis of ED and related physical therapy methods, and explored the pathogenesis of ED. In our opinion, these treatment methods could help many ED patients recover fully or partially from ED within the next few decades.
Collapse
Affiliation(s)
- Kun Pang
- Department of Urology, Xuzhou Central Hospital, Xuzhou Clinical College of Xuzhou Medical University, The Affiliated Xuzhou Hospital of Medical College of Southeast University, The Affiliated Xuzhou Center Hospital of Nanjing University of Chinese Medicine, Xuzhou, Jiangsu, China
| | - Deng Pan
- Graduate School, Bengbu Medical College, Bengbu, Anhui, China
| | - Hao Xu
- Graduate School, Bengbu Medical College, Bengbu, Anhui, China
| | - Yuyang Ma
- Graduate School, Bengbu Medical College, Bengbu, Anhui, China
| | - Jingkai Wang
- Graduate School, Jiangsu University, Zhenjiang, Jiangsu Province, China
| | - Peng Xu
- Graduate School, Jiangsu University, Zhenjiang, Jiangsu Province, China
| | - Hailuo Wang
- Department of Urology, Xuzhou Central Hospital, Xuzhou Clinical College of Xuzhou Medical University, The Affiliated Xuzhou Hospital of Medical College of Southeast University, The Affiliated Xuzhou Center Hospital of Nanjing University of Chinese Medicine, Xuzhou, Jiangsu, China
| | - Guanghui Zang
- Department of Urology, Xuzhou Central Hospital, Xuzhou Clinical College of Xuzhou Medical University, The Affiliated Xuzhou Hospital of Medical College of Southeast University, The Affiliated Xuzhou Center Hospital of Nanjing University of Chinese Medicine, Xuzhou, Jiangsu, China,*Correspondence: Guanghui Zang,
| |
Collapse
|
9
|
Wieske V, Walther M, Dubourg B, Alkadhi H, Nørgaard BL, Meijs MFL, Diederichsen ACP, Wan YL, Mickley H, Nikolaou K, Shabestari AA, Halvorsen BA, Martuscelli E, Sun K, Herzog BA, Marcus RP, Leschka S, Garcia MJ, Ovrehus KA, Knuuti J, Mendoza-Rodriguez V, Bettencourt N, Muraglia S, Buechel RR, Kaufmann PA, Zimmermann E, Tardif JC, Budoff MJ, Schlattmann P, Dewey M. Computed tomography angiography versus Agatston score for diagnosis of coronary artery disease in patients with stable chest pain: individual patient data meta-analysis of the international COME-CCT Consortium. Eur Radiol 2022; 32:5233-5245. [PMID: 35267094 PMCID: PMC9279219 DOI: 10.1007/s00330-022-08619-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 01/05/2022] [Accepted: 01/28/2022] [Indexed: 11/29/2022]
Abstract
OBJECTIVES There is conflicting evidence about the comparative diagnostic accuracy of the Agatston score versus computed tomography angiography (CTA) in patients with suspected obstructive coronary artery disease (CAD). PURPOSE To determine whether CTA is superior to the Agatston score in the diagnosis of CAD. METHODS In total 2452 patients with stable chest pain and a clinical indication for invasive coronary angiography (ICA) for suspected CAD were included by the Collaborative Meta-analysis of Cardiac CT (COME-CCT) Consortium. An Agatston score of > 400 was considered positive, and obstructive CAD defined as at least 50% coronary diameter stenosis on ICA was used as the reference standard. RESULTS Obstructive CAD was diagnosed in 44.9% of patients (1100/2452). The median Agatston score was 74. Diagnostic accuracy of CTA for the detection of obstructive CAD (81.1%, 95% confidence interval [CI]: 77.5 to 84.1%) was significantly higher than that of the Agatston score (68.8%, 95% CI: 64.2 to 73.1%, p < 0.001). Among patients with an Agatston score of zero, 17% (101/600) had obstructive CAD. Diagnostic accuracy of CTA was not significantly different in patients with low to intermediate (1 to < 100, 100-400) versus moderate to high Agatston scores (401-1000, > 1000). CONCLUSIONS Results in our international cohort show CTA to have significantly higher diagnostic accuracy than the Agatston score in patients with stable chest pain, suspected CAD, and a clinical indication for ICA. Diagnostic performance of CTA is not affected by a higher Agatston score while an Agatston score of zero does not reliably exclude obstructive CAD. KEY POINTS • CTA showed significantly higher diagnostic accuracy (81.1%, 95% confidence interval [CI]: 77.5 to 84.1%) for diagnosis of coronary artery disease when compared to the Agatston score (68.8%, 95% CI: 64.2 to 73.1%, p < 0.001). • Diagnostic performance of CTA was not affected by increased amount of calcium and was not significantly different in patients with low to intermediate (1 to <100, 100-400) versus moderate to high Agatston scores (401-1000, > 1000). • Seventeen percent of patients with an Agatston score of zero showed obstructive coronary artery disease by invasive angiography showing absence of coronary artery calcium cannot reliably exclude coronary artery disease.
Collapse
Affiliation(s)
- Viktoria Wieske
- Department of Radiology, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Mario Walther
- Department of Fundamental Sciences, Jena University of Applied Sciences, Jena, Germany
| | - Benjamin Dubourg
- Cardiac Imaging Unit, Department of Radiology, Rouen University Hospital, Rouen, France
| | - Hatem Alkadhi
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
| | - Bjarne L Nørgaard
- Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| | - Matthijs F L Meijs
- Department of Cardiology, University Medical Centre Utrecht, Utrecht, Netherlands
| | | | - Yung-Liang Wan
- Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Chang Gung Memorial Hospital at Linkou, Taoyaun City, Taiwan
| | - Hans Mickley
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, Tübingen, Germany
| | - Abbas A Shabestari
- Modarres Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | | | - Eugenio Martuscelli
- Department of Internal Medicine, University of Rome Tor Vergata, Rome, Italy
| | - Kai Sun
- Department of Radiology, Baotou Central Hospital, Baotou, Inner Mongolia Province, China
| | | | - Roy P Marcus
- Cantonal Hospital of Lucerne, Lucerne, Switzerland
| | - Sebastian Leschka
- Department of Radiology, Kantonsspital St Gallen, St Gallen, Switzerland
| | - Mario J Garcia
- Department of Cardiology, Montefiore, University Hospital for the Albert Einstein College of Medicine, New York, NY, USA
| | | | - Juhani Knuuti
- Turku University Hospital and University of Turku, Turku, Finland
| | | | - Nuno Bettencourt
- Department of Cardiology, Centro Hospitalar de Vila Nova de Gaia, Vila Nova de Gaia, Portugal
| | | | - Ronny R Buechel
- Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
| | - Philipp A Kaufmann
- Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
| | - Elke Zimmermann
- Department of Radiology, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | | | | | - Peter Schlattmann
- Institute of Medical Statistics, Computer Sciences and Data Science, University Hospital of Friedrich Schiller University Jena, Jena, Germany
| | - Marc Dewey
- Department of Radiology, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany.
| |
Collapse
|
10
|
Importance of the heart rate in ultra-high-resolution coronary CT angiography with 0.35 s gantry rotation time. Jpn J Radiol 2022; 40:781-790. [PMID: 35396666 DOI: 10.1007/s11604-022-01265-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 03/08/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE We investigated the effects of the heart rate (HR) on the motion artifact in coronary computed tomography angiography (CCTA) with ultra-high-resolution-CT (U-HRCT), and we clarified the upper limit of optimal HR in CCTA with U-HRCT in a comparison with conventional-resolution-CT (CRCT) on a cardiac phantom and in patients with CCTA. MATERIALS AND METHODS A pulsating cardiac phantom equipped with coronary models was scanned at static and HR simulations of 40-90 beats/min (bpm) at 10-bpm intervals using U-HRCT and CRCT, respectively. The sharpness and lumen diameter of the coronary model were quantitatively compared between U-HRCT and CRCT stratified by HR in the phantom study. We also assessed the visual inspections of clinical images in CCTA with U-HRCT. RESULTS At the HRs ≤ 60 bpm, the error of the lumen diameter of the U-HRCT tended to be smaller than that of the CRCT. However, at the HRs > 60 bpm, the inverse was shown. For the image sharpness, the U-HRCT was significantly superior to the CRCT (p < 0.05). In the visual assessment, the scores were negatively correlated with HRs in patients (Spearman r = - 0.71, p < 0.01). A receiver-operating characteristic analysis revealed the HR of 61 bpm as the optimal cutoff of the non-diagnostic image quality, with an area under the curve of 0.87, 95% sensitivity, and 71% specificity. CONCLUSION At HRs ≤ 60 bpm, U-HRCT was more accurate in the imaging of coronary arteries than CRCT. The upper limit of the optimal HR in CCTA with U-HRCT was approx. 60 bpm.
Collapse
|
11
|
Wu PW, Tsay PK, Sun Z, Peng SJ, Lee CY, Hsu MY, Ko YS, Hsieh IC, Wen MS, Wan YL. Added Value of Computed Tomography Virtual Intravascular Endoscopy in the Evaluation of Coronary Arteries with Stents or Plaques. Diagnostics (Basel) 2022; 12:diagnostics12020390. [PMID: 35204481 PMCID: PMC8871267 DOI: 10.3390/diagnostics12020390] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/16/2022] [Accepted: 01/31/2022] [Indexed: 11/16/2022] Open
Abstract
Coronary computed tomography angiography (CCTA) is a widely used imaging modality for diagnosing coronary artery disease (CAD) but is limited by a high false positive rate when evaluating coronary arteries with stents and heavy calcifications. Virtual intravascular endoscopy (VIE) images generated from CCTA can be used to qualitatively assess the vascular lumen and might be helpful for overcoming this challenge. In this study, one hundred subjects with coronary stents underwent both CCTA and invasive coronary angiography (ICA). A total of 902 vessel segments were analyzed using CCTA and VIE. The vessel segments were first analyzed on CCTA alone. Then, using VIE, the segments were classified qualitatively as either negative or positive for in-stent restenosis (ISR) or CAD. These results were compared, using ICA as the reference, to determine the added diagnostic value of VIE. Of the 902 analyzed vessel segments, CCTA/VIE had sensitivity, specificity, accuracy, positive predictive value, and negative predictive value (shown in %) of 93.9/90.2, 96.2/98.2, 96.0/97.7, 70.0/83.1, and 99.4/99.0, respectively, in diagnosing ISR or CAD, with significantly improved specificity (p = 0.025), accuracy (p = 0.046), and positive predictive value (p = 0.047). VIE can be a helpful addition to CCTA when evaluating coronary arteries.
Collapse
Affiliation(s)
- Patricia Wanping Wu
- Department of Medical Imaging and Intervention, Linkou Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Taoyuan City 333423, Taiwan; (P.W.W.); (M.-Y.H.)
| | - Pei-Kwei Tsay
- Department of Public Health and Center of Biostatistics, College of Medicine, Chang Gung University, Taoyuan City 333323, Taiwan;
| | - Zhonghua Sun
- Discipline of Medical Radiation Science, Curtin Medical School, Curtin University, Bentley, WA 6102, Australia;
| | - Syu-Jyun Peng
- Professional Master Program in Artificial Intelligence in Medicine, College of Medicine, Taipei Medical University, Taipei City 110301, Taiwan;
| | - Chia-Yen Lee
- Department of Electrical Engineering, National United University, Miaoli 360302, Taiwan;
| | - Ming-Yi Hsu
- Department of Medical Imaging and Intervention, Linkou Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Taoyuan City 333423, Taiwan; (P.W.W.); (M.-Y.H.)
| | - Yu-Shien Ko
- Department of Cardiology, Linkou Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Taoyuan City 333423, Taiwan; (Y.-S.K.); (I.-C.H.); (M.-S.W.)
| | - I-Chang Hsieh
- Department of Cardiology, Linkou Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Taoyuan City 333423, Taiwan; (Y.-S.K.); (I.-C.H.); (M.-S.W.)
| | - Ming-Shien Wen
- Department of Cardiology, Linkou Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Taoyuan City 333423, Taiwan; (Y.-S.K.); (I.-C.H.); (M.-S.W.)
| | - Yung-Liang Wan
- Department of Medical Imaging and Intervention, Linkou Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Taoyuan City 333423, Taiwan; (P.W.W.); (M.-Y.H.)
- Correspondence: ; Tel.: +886-3-3281200 (ext. 2575)
| |
Collapse
|
12
|
Bhatti S, Lizaola-Mayo B, Al-Shoha M, Garcia-Saenz-de-Sicilia M, Habash F, Ayoub K, Karr M, Ahmed Z, Borja-Cacho D, Duarte-Rojo A. Use of Computed Tomography Coronary Calcium Score for Coronary Artery Disease Risk Stratification During Liver Transplant Evaluation. J Clin Exp Hepatol 2022; 12:319-328. [PMID: 35535104 PMCID: PMC9077224 DOI: 10.1016/j.jceh.2021.08.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Accepted: 08/14/2021] [Indexed: 12/12/2022] Open
Abstract
Background End-stage liver disease (ESLD) is not considered a risk factor for atherosclerotic cardiovascular disease (ASCVD). However, lifestyle characteristics commonly associated with increased ASCVD risk are highly prevalent in ESLD. Emerging literature shows a high burden of asymptomatic coronary artery disease (CAD) in patients with ESLD and a high ASCVD risk in liver transplantation (LT) recipients. Coronary artery calcium score (CAC) is a noninvasive test providing reliable CAD risk stratification. We implemented an LT evaluation protocol with CAC playing a central role in triaging and determining the need for further CAD assessment. Here, we inform our results from this early experience. Methods Patients with ESLD referred for LT evaluation were prospectively studied. We compared accuracy of CAC against that of CAD risk factors/scores, troponin I, dobutamine stress echocardiogram (DSE), and single-photon emission computed tomography (SPECT) to detect coronary stenosis ≥70 (CAD ≥ 70) per left heart catheterization (LHC). Thirty-day post-LT cardiac outcomes were also analyzed. Results One hundred twenty-four of 148 (84%) patients underwent CAC, 106 (72%) DSE/SPECT, and 50 (34%) LHC. CAC ≥ 400 was found in 35 (28%), 100 to 399 in 17 (14%), and <100 in 72 (58%). LHC identified CAD ≥ 70% in 8 of 29 (28%), 2 of 9 (22%), and 0 of 4, respectively. Two acute coronary syndromes occurred after LT in a patient with CAC 811 (CAD < 70%), and one with CAC 347 (CAD ≥ 70%). No patients with CAC < 100 presented with acute coronary syndrome after LT. When using CAD ≥ 70% as primary endpoint of LT evaluation, CAC ≥ 346 was the only test showing predictive usefulness (negative predictive value 100%). Conclusions CAC is a promising tool to guide CAD risk stratification and need for LHC during LT evaluation. Patients with a CAC < 100 can safely undergo LT without the need for LHC or cardiac stress testing, whereas a CAC < 346 accurately rules out significant CAD stenosis (≥70%) on LHC, outperforming other CAD risk-stratification strategies.
Collapse
Key Words
- ACS, Acute coronary syndromes
- ALD, alcoholic liver disease
- ASCVD, Atherosclerotic cardiovascular disease
- ASCVD, atherosclerosis cardiovascular disease risk
- BMI, Body mass index
- CABG, Coronary angioplasty bypass surgery
- CAC, Coronary calcium score
- CAD, Coronary artery disease
- CKD, chronic kidney disease
- DSE/SPECT, Dobutamine stress echocardiogram or single-photon emission computed tomography
- ESLD, End-stage liver disease
- HCV, hepatitis C virus
- IQR, Interquartile range
- LCx, left circumflex
- LHC, Left heart catheterization
- LT, liver transplantation
- MELD, model for end stage liver disease
- MESA, Multi-Ethnic Study of Atherosclerosis
- METs, Metabolic equivalents
- NPV, negative predictive value
- OM, obtuse marginal
- OPTN, Organ Procurement and Transplantation Network
- PCI, Percutaneous coronary intervention
- PDA, posterior descending artery
- POBA, plain old balloon angioplasty
- PPV, positive predictive value
- RCA, right coronary artery
- RI, ramus intermedius
- ROC, Receiver operating characteristic
- RPL, right posterolateral
- SD, Standard deviation
- VT, Ventricular tachycardia
- agatston score
- angiogram
- cardiac stress test
- cirrhosis
- end-stage liver disease
Collapse
Affiliation(s)
- Sabha Bhatti
- Division of Cardiology, University of Arkansas for Medical Sciences, 4301 W. Markham Slot #567, Little Rock, AR, 70205, United States
| | - Blanca Lizaola-Mayo
- Division of Gastroenterology and Hepatology, Mayo Clinic, 13400 East Shea Blvd, Scottsdale, AZ, 85259, United States
| | - Mohammad Al-Shoha
- Division of Gastroenterology and Hepatology, University of Arkansas for Medical Sciences, 4301 W. Markham Slot #567, Little Rock, AR, 70205, United States
| | | | - Fuad Habash
- Department of Internal Medicine, University of Arkansas for Medical Sciences, 4301 W. Markham Slot #567, Little Rock, AR, 70205, United States
| | - Karam Ayoub
- Department of Internal Medicine, University of Arkansas for Medical Sciences, 4301 W. Markham Slot #567, Little Rock, AR, 70205, United States
| | - Michael Karr
- Department of Internal Medicine, University of Arkansas for Medical Sciences, 4301 W. Markham Slot #567, Little Rock, AR, 70205, United States
| | - Zubair Ahmed
- Division of Cardiology, University of Arkansas for Medical Sciences, 4301 W. Markham Slot #567, Little Rock, AR, 70205, United States
| | - Daniel Borja-Cacho
- Division of Transplant Surgery, Northwestern University, 676 N Saint Clair, Chicago, IL, 60611, United States
| | - Andres Duarte-Rojo
- Division of Cardiology, University of Arkansas for Medical Sciences, 4301 W. Markham Slot #567, Little Rock, AR, 70205, United States
- Thomas E. Starzl Transplantation Institute and Division of Gastroenterology, Hepatology and Nutrition; University of Pittsburgh Medical Center, 3471 Fifth Avenue, Suite 916, Pittsburgh, PA, 15213, United States
- Address for correspondence: Andres Duarte-Rojo, MD, MS, DSc, Starzl Transplantation Institute and Center for Liver Diseases, University of Pittsburgh Medical Center, 3471 Fifth Avenue, Suite 916, Pittsburgh, PA, 15213, United States. Tel.: +1 412 647-1170; fax: +1 412 647 9268
| |
Collapse
|
13
|
Cardoso S, Azevedo CFD, Fernandes F, Ianni B, Torreão JA, Marques MD, Ávila LFRD, Santos R, Mady C, Kalil-Filho R, Ramires JAF, Bittencourt MS, Rochitte CE. Menor Prevalência e Extensão da Aterosclerose Coronária na Doença de Chagas Crônica por Angiotomografia Coronária. Arq Bras Cardiol 2020; 115:1051-1060. [PMID: 33470300 PMCID: PMC8133709 DOI: 10.36660/abc.20200342] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 11/06/2020] [Indexed: 11/18/2022] Open
|
14
|
Health Care Monitoring and Treatment for Coronary Artery Diseases: Challenges and Issues. SENSORS 2020; 20:s20154303. [PMID: 32752231 PMCID: PMC7435700 DOI: 10.3390/s20154303] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 07/09/2020] [Accepted: 07/12/2020] [Indexed: 01/03/2023]
Abstract
In-stent restenosis concerning the coronary artery refers to the blood clotting-caused re-narrowing of the blocked section of the artery, which is opened using a stent. The failure rate for stents is in the range of 10% to 15%, where they do not remain open, thereby leading to about 40% of the patients with stent implantations requiring repeat procedure within one year, despite increased risk factors and the administration of expensive medicines. Hence, today stent restenosis is a significant cause of deaths globally. Monitoring and treatment matter a lot when it comes to early diagnosis and treatment. A review of the present stent monitoring technology as well as the practical treatment for addressing stent restenosis was conducted. The problems and challenges associated with current stent monitoring technology were illustrated, along with its typical applications. Brief suggestions were given and the progress of stent implants was discussed. It was revealed that prime requisites are needed to achieve good quality implanted stent devices in terms of their size, reliability, etc. This review would positively prompt researchers to augment their efforts towards the expansion of healthcare systems. Lastly, the challenges and concerns associated with nurturing a healthcare system were deliberated with meaningful evaluations.
Collapse
|
15
|
Kofler A, Haltmeier M, Schaeffter T, Kachelrieß M, Dewey M, Wald C, Kolbitsch C. Neural networks-based regularization for large-scale medical image reconstruction. Phys Med Biol 2020; 65:135003. [PMID: 32492660 DOI: 10.1088/1361-6560/ab990e] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
In this paper we present a generalized Deep Learning-based approach for solving ill-posed large-scale inverse problems occuring in medical image reconstruction. Recently, Deep Learning methods using iterative neural networks (NNs) and cascaded NNs have been reported to achieve state-of-the-art results with respect to various quantitative quality measures as PSNR, NRMSE and SSIM across different imaging modalities. However, the fact that these approaches employ the application of the forward and adjoint operators repeatedly in the network architecture requires the network to process the whole images or volumes at once, which for some applications is computationally infeasible. In this work, we follow a different reconstruction strategy by strictly separating the application of the NN, the regularization of the solution and the consistency with the measured data. The regularization is given in the form of an image prior obtained by the output of a previously trained NN which is used in a Tikhonov regularization framework. By doing so, more complex and sophisticated network architectures can be used for the removal of the artefacts or noise than it is usually the case in iterative NNs. Due to the large scale of the considered problems and the resulting computational complexity of the employed networks, the priors are obtained by processing the images or volumes as patches or slices. We evaluated the method for the cases of 3D cone-beam low dose CT and undersampled 2D radial cine MRI and compared it to a total variation-minimization-based reconstruction algorithm as well as to a method with regularization based on learned overcomplete dictionaries. The proposed method outperformed all the reported methods with respect to all chosen quantitative measures and further accelerates the regularization step in the reconstruction by several orders of magnitude.
Collapse
Affiliation(s)
- A Kofler
- Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | | | | | | | | | | | | |
Collapse
|
16
|
Stepniak K, Ursani A, Paul N, Naguib H. Novel 3D printing technology for CT phantom coronary arteries with high geometrical accuracy for biomedical imaging applications. ACTA ACUST UNITED AC 2020. [DOI: 10.1016/j.bprint.2020.e00074] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
17
|
Saito T, Kasai H, Sugiura T, Takahashi Y, Tajima H, Shigeta A, Sakao S, Tanabe N, Tatsumi K. Effects of pulmonary endarterectomy on pulmonary hemodynamics in chronic thromboembolic pulmonary hypertension, evaluated by interventricular septum curvature. Pulm Circ 2020; 10:2045894019897502. [PMID: 32206304 DOI: 10.1177/2045894019897502] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 11/25/2019] [Indexed: 10/25/2022] Open
Abstract
The interventricular septum curvature, measured in images of electrocardiogram-gated 320-slice multidetector computed tomography, is reportedly useful and less invasive than right heart catheterization, as it could provide clues regarding pulmonary arterial pressure in patients with chronic thromboembolic pulmonary hypertension. Although pulmonary endarterectomy is an efficient treatment for chronic thromboembolic pulmonary hypertension, the interventricular septum curvature in patients who have received pulmonary endarterectomy has not been evaluated. We evaluated whether the interventricular septum curvature on electrocardiogram-gated 320-slice multidetector computed tomography can predict pulmonary hemodynamics in chronic thromboembolic pulmonary hypertension even after pulmonary endarterectomy. We studied 40 patients with chronic thromboembolic pulmonary hypertension (60.5 ± 9.7 years; 30 females), who underwent pulmonary endarterectomy at Chiba University Hospital between December 2010 and July 2018. To measure the interventricular septum curvature, we prepared left ventricular short-axis tomographic images from 4D images of electrocardiogram-gated 320-slice multidetector computed tomography. We calculated the radius of interventricular septum and determined the interventricular septum curvature in both the systolic and diastolic phases. We compared the interventricular septum curvature with pulmonary hemodynamics measured by right heart catheterization before and after pulmonary endarterectomy. After pulmonary endarterectomy, the correlations of the interventricular septum curvature with mean pulmonary arterial pressure, systolic pulmonary arterial pressure, and pulmonary vascular resistance disappeared, although the interventricular septum curvature was correlated with these pulmonary hemodynamic parameters before pulmonary endarterectomy. Changes in systolic interventricular septum curvature revealed significant correlations with changes in mean pulmonary arterial pressure, systolic pulmonary arterial pressure and pulmonary vascular resistance. Diastolic interventricular septum curvature also showed significant correlations with preoperative pulmonary hemodynamics, but not with postoperative pulmonary hemodynamics. Changes in the interventricular septum curvature after pulmonary endarterectomy could estimate the efficacy of pulmonary endarterectomy, although the interventricular septum curvature after pulmonary endarterectomy showed no significant correlations with pulmonary hemodynamics. Additionally, our findings confirmed that the interventricular septum curvature before pulmonary endarterectomy could be used to evaluate the severity of disease.
Collapse
Affiliation(s)
| | - Hajime Kasai
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Toshihiko Sugiura
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Yukiko Takahashi
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Hiroshi Tajima
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Ayako Shigeta
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Seiichiro Sakao
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Nobuhiro Tanabe
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Koichiro Tatsumi
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Japan
| |
Collapse
|
18
|
Shirasaka T, Nagao M, Yamasaki Y, Kojima T, Kondo M, Hamasaki H, Kamitani T, Kato T, Asayama Y. Low Radiation Dose and High Image Quality of 320-Row Coronary Computed Tomography Angiography Using a Small Dose of Contrast Medium and Refined Scan Timing Prediction. J Comput Assist Tomogr 2020; 44:7-12. [PMID: 31939875 DOI: 10.1097/rct.0000000000000951] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The aim of the study was to investigate the feasibility of coronary computed tomography (CT) angiography with a low kilovoltage peak scan and a refined scan timing prediction using a small contrast medium (CM) dose. METHODS In protocol A, 120-kVp scanning and a standard CM dose were used. The scan timing was fixed. In protocol B, 80 kVp and a 60% CM dose were used. The scan timing was determined according to the interval from the CM arrival to the peak time in the ascending aorta. We measured the CT number and recorded the radiation dose. RESULTS Higher CT numbers were observed in the left circumflex (proximal, P = 0.0235; middle, P = 0.0007; distal, P < 0.0001) in protocol B compared with protocol A. The radiation dose in protocol B was significantly lower than in protocol A (2.2 ± 0.9 vs 4.3 ± 1.7 mSv). CONCLUSIONS Low-contrast, low-radiation dose, high-image quality coronary CT angiography can be performed with low kilovoltage peak scanning and a refined scan timing prediction.
Collapse
Affiliation(s)
- Takashi Shirasaka
- From the Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka Prefecture
| | - Michinobu Nagao
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Shinjuku-ku, Tokyo
| | | | - Tsukasa Kojima
- From the Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka Prefecture
| | - Masatoshi Kondo
- From the Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka Prefecture
| | - Hiroshi Hamasaki
- From the Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka Prefecture
| | | | - Toyoyuki Kato
- From the Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka Prefecture
| | - Yoshiki Asayama
- Advanced Imaging and Interventional Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Fukuoka Prefecture, Japan
| |
Collapse
|
19
|
Koplay M, Gok M, Sivri M. The association between coronary artery disease and nonalcoholic fatty liver disease and noninvasive imaging methods. ELECTRONIC JOURNAL OF GENERAL MEDICINE 2019. [DOI: 10.29333/ejgm/110689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
20
|
Israel O, Pellet O, Biassoni L, De Palma D, Estrada-Lobato E, Gnanasegaran G, Kuwert T, la Fougère C, Mariani G, Massalha S, Paez D, Giammarile F. Two decades of SPECT/CT - the coming of age of a technology: An updated review of literature evidence. Eur J Nucl Med Mol Imaging 2019; 46:1990-2012. [PMID: 31273437 PMCID: PMC6667427 DOI: 10.1007/s00259-019-04404-6] [Citation(s) in RCA: 124] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Accepted: 06/14/2019] [Indexed: 02/08/2023]
Abstract
PURPOSE Single-photon emission computed tomography (SPECT) combined with computed tomography (CT) was introduced as a hybrid SPECT/CT imaging modality two decades ago. The main advantage of SPECT/CT is the increased specificity achieved through a more precise localization and characterization of functional findings. The improved diagnostic accuracy is also associated with greater diagnostic confidence and better inter-specialty communication. METHODS This review presents a critical assessment of the relevant literature published so far on the role of SPECT/CT in a variety of clinical conditions. It also includes an update on the established evidence demonstrating both the advantages and limitations of this modality. CONCLUSIONS For the majority of applications, SPECT/CT should be a routine imaging technique, fully integrated into the clinical decision-making process, including oncology, endocrinology, orthopaedics, paediatrics, and cardiology. Large-scale prospective studies are lacking, however, on the use of SPECT/CT in certain clinical domains such as neurology and lung disorders. The review also presents data on the complementary role of SPECT/CT with other imaging modalities and a comparative analysis, where available.
Collapse
Affiliation(s)
- Ora Israel
- Rappaport School of Medicine, Israel Institute of Technology, Haifa, Israel.
| | - O Pellet
- Nuclear Medicine and Diagnostic Imaging Section International Atomic Energy Agency, Vienna, Austria
| | - L Biassoni
- Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - D De Palma
- Nuclear Medicine Unit, Circolo Hospital, ASST-Settelaghi, Varese, Italy
| | - E Estrada-Lobato
- Nuclear Medicine and Diagnostic Imaging Section International Atomic Energy Agency, Vienna, Austria
| | - G Gnanasegaran
- Department of Nuclear Medicine, Royal Free NHS Foundation Trust, London, UK
| | - T Kuwert
- Clinic of Nuclear Medicine, University Hospital, Erlangen, Germany
| | - C la Fougère
- Division of Nuclear Medicine and Clinical Molecular Imaging, Department of Radiology, University Hospital, Tubingen, Germany
| | - G Mariani
- Regional Center of Nuclear Medicine, University of Pisa, Pisa, Italy
| | - S Massalha
- Department of Medicine, University of Ottawa Heart Institute, Ottawa, Canada
- Department of Nuclear Medicine, Rambam Healthcare Campus, Haifa, Israel
| | - D Paez
- Nuclear Medicine and Diagnostic Imaging Section International Atomic Energy Agency, Vienna, Austria
| | - F Giammarile
- Nuclear Medicine and Diagnostic Imaging Section International Atomic Energy Agency, Vienna, Austria
| |
Collapse
|
21
|
Diagnosis of coronary artery disease in patients with atrial fibrillation using low tube voltage coronary CT angiography with isotonic low-concentration contrast agent. Int J Cardiovasc Imaging 2019; 35:2239-2248. [PMID: 31363878 DOI: 10.1007/s10554-019-01678-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2019] [Accepted: 07/24/2019] [Indexed: 10/26/2022]
Abstract
This prospective study evaluated the image quality and accuracy of coronary computed tomography angiography (CCTA) for diagnosing coronary artery disease (CAD) in patients with atrial fibrillation (AF), in which CCTA used adaptive iterative dose reduction (AIDR) with a low tube voltage and low concentration of isotonic contrast agent. Sixty-eight consecutive patients with AF and suspected CAD were equally and randomly apportioned to two groups and underwent CCTA. In the experimental group, the contrast agent was iodixanol (270 mg I/mL), patients were scanned with 100 kV, and reconstruction was by AIDR. In the conventional scanning (control) group, the contrast agent was iopromide (370 mg I/mL), patients were scanned with 120 kV, and reconstruction was by filtered back projection. The image quality, effective radiation dose (E), and total iodine intake of the groups were compared. Thirty-nine patients with coronary artery stenosis later were given invasive coronary angiography (ICA). The groups were similar with regard to mean CT value, noise, and signal-to-noise and contrast-to-noise ratios. The figure of merit of the experimental group was significantly higher than that of the control group, while the E and total iodine were significantly lower. Using ICA as the diagnostic reference, the groups shared similar sensitivity, specificity, and false positive and false negative rates for diagnosing coronary artery stenosis. For determining CAD in patients with AF, CCTA with isotonic low-concentration contrast agent and low-voltage scanning is a feasible alternative that improves accuracy and reduces radiation dose and iodine intake.
Collapse
|
22
|
|
23
|
Seppelt D, Kolb C, Kühn JP, Speiser U, Radosa CG, Hoberück S, Hoffmann RT, Platzek I. Comparison of sequential and high-pitch-spiral coronary CT-angiography: image quality and radiation exposure. Int J Cardiovasc Imaging 2019; 35:1379-1386. [PMID: 30850908 DOI: 10.1007/s10554-019-01568-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Accepted: 02/21/2019] [Indexed: 12/28/2022]
Abstract
New protocols for coronary computed tomography angiography (CCTA) could lower the radiation dose for patients but influence the image quality. To compare image quality and radiation exposure in step-and-shoot CCTA and high-pitch spiral CCTA. Fifty-nine pairs of patients matched for weight, height, sex and heart rate were included in this study (74 m, 44 f, average age 60 years, age range 29-94 years). Step-and-shoot CCTA and high-pitch spiral CCTA was performed on a third generation dual-source CT in equally sized patient groups. The signal-to-noise ratio (SNR) in the ascending aorta and the coronary arteries were determined for each dataset. Image quality was rated using a five-point scale. We used the t-test for paired samples to compare SNR and effective dose, and the Wilcoxon test to compare image quality scores. Mean effective dose for the step-and-shoot protocol (4.15 ± 3.07 mSv) was significantly higher in comparison to the high-pitch spiral protocol (1.2 ± 0.69 mSv; p < 0.0001). Mean SNR was higher with the step-and-shoot protocol compared to the high-pitch spiral protocol in the aorta, in the left main and peripheral coronary arteries (p < 0.01), in the proximal right coronary artery (p = 0.027). Image quality scores were significantly better for the step-and-shoot protocol (p = 0.0003). Step-and-shoot CCTA has significantly better SNR and overall image quality compared to high-pitch spiral CCTA, but with a mean effective dose more than thrice as high.
Collapse
Affiliation(s)
- D Seppelt
- Institute and Policlinic for Diagnostic and Interventional Radiology, Dresden University Hospital, Carl-Gustav-Carus University, Fetscherstraße 74, 01307, Dresden, Germany.
| | - C Kolb
- Institute and Policlinic for Diagnostic and Interventional Radiology, Dresden University Hospital, Carl-Gustav-Carus University, Fetscherstraße 74, 01307, Dresden, Germany
| | - J P Kühn
- Institute and Policlinic for Diagnostic and Interventional Radiology, Dresden University Hospital, Carl-Gustav-Carus University, Fetscherstraße 74, 01307, Dresden, Germany
| | - U Speiser
- Department of Cardiology, Heart Centre Dresden University Hospital, Fetscherstraße 76, 01307, Dresden, Germany
| | - C G Radosa
- Institute and Policlinic for Diagnostic and Interventional Radiology, Dresden University Hospital, Carl-Gustav-Carus University, Fetscherstraße 74, 01307, Dresden, Germany
| | - S Hoberück
- Department of Nuclear Medicine, Dresden University Hospital, Fetscherstraße 74, 01307, Dresden, Germany
| | - R T Hoffmann
- Institute and Policlinic for Diagnostic and Interventional Radiology, Dresden University Hospital, Carl-Gustav-Carus University, Fetscherstraße 74, 01307, Dresden, Germany
| | - I Platzek
- Institute and Policlinic for Diagnostic and Interventional Radiology, Dresden University Hospital, Carl-Gustav-Carus University, Fetscherstraße 74, 01307, Dresden, Germany
| |
Collapse
|
24
|
Song YB, Arbab-Zadeh A, Matheson MB, Ostovaneh MR, Vavere AL, Dewey M, Rochitte C, Niinuma H, Laham R, Schuijf JD, Cox C, Brinker J, di Carli M, Lima JA, Miller JM. Contemporary Discrepancies of Stenosis Assessment by Computed Tomography and Invasive Coronary Angiography. Circ Cardiovasc Imaging 2019; 12:e007720. [DOI: 10.1161/circimaging.118.007720] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Young Bin Song
- Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea (Y.B.S.)
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD (Y.B.S., A.A.-Z., M.R.O., A.L.V., J.B., J.A.C.L., J.M.M.)
| | - Armin Arbab-Zadeh
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD (Y.B.S., A.A.-Z., M.R.O., A.L.V., J.B., J.A.C.L., J.M.M.)
| | - Matthew B. Matheson
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD (M.B.M., C.C.)
| | - Mohammad R. Ostovaneh
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD (Y.B.S., A.A.-Z., M.R.O., A.L.V., J.B., J.A.C.L., J.M.M.)
| | - Andrea L. Vavere
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD (Y.B.S., A.A.-Z., M.R.O., A.L.V., J.B., J.A.C.L., J.M.M.)
| | - Marc Dewey
- Department of Radiology, Charité Medical School, Humboldt, Berlin, Germany (M.D.)
| | - Carlos Rochitte
- Department of Medicine, InCor Heart Institute, University of Sao Paulo Medical School, Brazil (C.R.)
| | - Hiroyuki Niinuma
- Department of Medicine, Division of Cardiology, Memorial Heart Center, Iwate Medical University, Morioka, Japan (H.N.)
| | - Roger Laham
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard University, Boston, MA (R.L.)
| | | | - Christopher Cox
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD (M.B.M., C.C.)
| | - Jeffrey Brinker
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD (Y.B.S., A.A.-Z., M.R.O., A.L.V., J.B., J.A.C.L., J.M.M.)
| | - Marcelo di Carli
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA (M.d.C.)
| | - João A.C. Lima
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD (Y.B.S., A.A.-Z., M.R.O., A.L.V., J.B., J.A.C.L., J.M.M.)
| | - Julie M. Miller
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD (Y.B.S., A.A.-Z., M.R.O., A.L.V., J.B., J.A.C.L., J.M.M.)
| |
Collapse
|
25
|
Shirasaka T, Nagao M, Yamasaki Y, Kojima T, Kondo M, Shimomiya Y, Kamitani T, Honda H. Feasible scan timing for 320-row coronary CT angiography generated by the time to peak in the ascending aorta. Clin Imaging 2019; 54:153-158. [PMID: 30658213 DOI: 10.1016/j.clinimag.2019.01.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Revised: 12/28/2018] [Accepted: 01/07/2019] [Indexed: 10/27/2022]
Abstract
PURPOSE A 320-row CT scanner can briefly scan the entire heart. Therefore, the feasible scan timing is required. The aim of this study was to propose a refined method for feasible scan timing for coronary CT angiography (CCTA) using a time-density curve of the ascending aorta (AAo). METHODS One-hundred and twenty-nine patients were prospectively enrolled. All patients were performed test-bolus method. For the initial 65 patients, the scan timing was determined as a 3.0 s delay at the peak time in the AAo, which was defined as the conventional protocol (COV-P). For the next 64 patients, a scan timing of 1.0, 3.0, or 5.0 s delay was determined according to the interval from the contrast media arrival to peak time in the AAo, which was defined as the arrival to peak protocol (AP-P). The optimal scan timing was identified by the measurement of CT number in the left atrium, left ventricle, AAo, and descending aorta. The coronary enhancement and heterogeneity were compared between the two protocols. RESULTS The optimal scan timing was significantly higher in the AP-P than in the COV-P (85.9% vs. 61.5%, p = 0.0017). The CT number in the left circumflex artery (LCX) was significantly higher in the AP-P than the COV-P (344.5 Hounsfield units vs. 316.3 Hounsfield units, p = 0.0484). The heterogeneous index of the LCX was significantly greater for the COV-P than the AP-P (-36.8 vs. -25.8, p = 0.0028). CONCLUSIONS The AP-P can be used to determine the optimal scan timing for CCTA and contributes to stable coronary enhancement.
Collapse
Affiliation(s)
- Takashi Shirasaka
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3 Chome-1-1 Maidashi, Higashi Ward, Fukuoka, Fukuoka Prefecture 812-8582, Japan.
| | - Michinobu Nagao
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawata-cho, Shinjuku-ku, Tokyo 162-0054, Japan
| | - Yuzo Yamasaki
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3 Chome-1-1 Maidashi, Higashi Ward, Fukuoka, Fukuoka Prefecture 812-8582, Japan
| | - Tsukasa Kojima
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3 Chome-1-1 Maidashi, Higashi Ward, Fukuoka, Fukuoka Prefecture 812-8582, Japan
| | - Masatoshi Kondo
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3 Chome-1-1 Maidashi, Higashi Ward, Fukuoka, Fukuoka Prefecture 812-8582, Japan
| | - Yamato Shimomiya
- Ziosoft Inc., Mita Kokusai Bldg, 5F 1-4-28, Mita, Minato-ku, Tokyo 108-0073, Japan
| | - Takeshi Kamitani
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3 Chome-1-1 Maidashi, Higashi Ward, Fukuoka, Fukuoka Prefecture 812-8582, Japan
| | - Hiroshi Honda
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3 Chome-1-1 Maidashi, Higashi Ward, Fukuoka, Fukuoka Prefecture 812-8582, Japan
| |
Collapse
|
26
|
CTA Evaluation of Bioresorbable Scaffolds versus Metallic Coronary Stents – a Feasibility Study. JOURNAL OF INTERDISCIPLINARY MEDICINE 2018. [DOI: 10.2478/jim-2018-0033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Abstract
Background: Computed tomography angiography (CTA) presents important limits in in-stent restenosis (ISR) evaluation in case of metallic coronary stents, due to the artifacts determined by stent struts, which alter in-stent plaque analysis. In case of bioresorbable scaffolds, stent strut resorption allows accurate evaluation of the vessel wall. Aim of the study: This study aims to compare the feasibility of CTA as a follow-up imaging method for ISR diagnosis following elective PTCA procedures, between bioresorbable scaffolds and metallic coronary stents.
Material and methods: We conducted a prospective, observational study on 73 patients with elective PTCA procedures in their medical history, in whom 113 stents were assessed via CTA in order to diagnose ISR. Based on stent type, the patients were divided into two groups: Group 1 – patients with bioresorbable vascular scaffolds (BVS) (n = 30); and Group 2 – patients with bare metal stents (BMS) (n = 43). Plaque analysis was possible only in the BVS group with a post-processing research-dedicated software, Syngo.via Frontier, which identified plaque morphology and virtual histology composition.
Results: After CTA evaluation, the BVS group presented a significantly higher incidence of severe coronary artery disease (CAD) (Group 1 – 73% vs. Group 2 – 30%, p <0.0001). The proximal part of the right coronary artery (RCA) presented a significantly higher percentage of metallic stents (14% BMS vs. 2% BVS, p = 0.0029). The comparative analysis of CTA sensibility for the visual evaluation of ISR identified a significantly higher percentage of diagnostic CT evaluations in the BVS group (Group 1 – 94% vs. Group 2 – 76.19%, p = 0.0006). CTA evaluation provided the most accurate results for the 3.0 and 3.5 mm devices. Regarding CTA sensibility for ISR diagnosis, the BVS group presented the smallest incidence of non-diagnostic CT evaluations.
Conclusions: CTA evaluation of bioresorbable scaffolds is superior to metallic stent assessment, the latter being influenced by numerous sources of error dependent mainly on the presence of the metal structure.
Collapse
|
27
|
Mata-Mbemba D, Labani A, El Ghannudi S, Jeung MY, Ohlmann P, Roy C, Ohana M. 320-row CT transcatheter aortic valve replacement planning with a single reduced contrast media bolus injection. PLoS One 2018; 13:e0204145. [PMID: 30212567 PMCID: PMC6136810 DOI: 10.1371/journal.pone.0204145] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Accepted: 09/03/2018] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVE To reduce the iodine load required for CT Transcatheter Aortic Valve Replacement (TAVR) planning on a 320-row scanner by acquiring the two CT TAVR steps (ECG-gated aortic root CTA and non-gated aorto-ilio-femoral CTA) within a single contrast media bolus injection. METHODS 50 consecutive patients (82.6±6.9 years; 56% female) were prospectively enrolled and underwent a TAVR planning using a 320-row CT, with ECG-gated aortic root CTA immediately followed by a non-gated aorto-iliac acquisition, all within a single bolus of 40-70mL of Iohexol 350mgI/mL. The Iodine load, image quality, SNR, CNR and radiation dose were compared using a Mann-Whitney test to that of 24 consecutive patients (84.3±4.8 years, 58% female) previously imaged on a 64-row scanner with a conventional two-step protocol. RESULTS Iodine load was reduced by 44%. All examinations were of diagnostic quality, with improvement of the aortic root CTA image quality (4.9±0.3 versus 4.6±0.5, p<0.01) and a non-significant decrease of the aorto-iliac CTA image quality (4.7±0.6 versus 4.9±0.3, p = 0.07). SNR and CNR were significantly improved in the aortic root CTA (14.0±5.3 and 10.4±4.5 versus 10.3±4.2 and 6.8±3.3, p<0.01 for both) and non-significantly higher in the aorto-iliac CTA (16.5±8.0 and 14.1±7.9 versus 14.7±5.5 and 12.5±5.0, p = 0.42 and p = 0.66). Total radiation dose was reduced by 32%. CONCLUSION 320-row CT scanner enables a 44% reduction of iodine load in TAVR planning, while maintaining excellent aorto-ilio-femoral arterial enhancement and lowering radiation dose.
Collapse
Affiliation(s)
- Daddy Mata-Mbemba
- Department of Diagnostic Imaging, Hospital for Sick Children, Toronto, Ontario, Canada
| | - Aissam Labani
- Department of Diagnostic Imaging, Nouvel Hôpital Civil–Strasbourg University Hospital, Strasbourg, France
| | - Soraya El Ghannudi
- Department of Diagnostic Imaging, Nouvel Hôpital Civil–Strasbourg University Hospital, Strasbourg, France
| | - Mi-Young Jeung
- Department of Diagnostic Imaging, Nouvel Hôpital Civil–Strasbourg University Hospital, Strasbourg, France
| | - Patrick Ohlmann
- Department of Cardiology, Nouvel Hôpital Civil–Strasbourg University Hospital, Strasbourg, France
| | - Catherine Roy
- Department of Diagnostic Imaging, Nouvel Hôpital Civil–Strasbourg University Hospital, Strasbourg, France
| | - Mickaël Ohana
- Department of Diagnostic Imaging, Nouvel Hôpital Civil–Strasbourg University Hospital, Strasbourg, France
- iCube Laboratory, University of Strasbourg, Illkirch, France
- * E-mail:
| |
Collapse
|
28
|
Abd alamir M, Noack P, Jang KH, Moore JA, Goldberg R, Poon M. Computer-aided analysis of 64- and 320-slice coronary computed tomography angiography: a comparison with expert human interpretation. Int J Cardiovasc Imaging 2018; 34:1473-1483. [DOI: 10.1007/s10554-018-1361-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 04/20/2018] [Indexed: 10/17/2022]
|
29
|
Takagi H, Tanaka R, Nagata K, Ninomiya R, Arakita K, Schuijf JD, Yoshioka K. Diagnostic performance of coronary CT angiography with ultra-high-resolution CT: Comparison with invasive coronary angiography. Eur J Radiol 2018; 101:30-37. [PMID: 29571798 DOI: 10.1016/j.ejrad.2018.01.030] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 01/13/2018] [Accepted: 01/30/2018] [Indexed: 01/07/2023]
Abstract
PURPOSE Recently, ultra-high-resolution computed tomography (U-HRCT) with a 0.25 mm × 128-row detector was introduced. The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (CCTA) using U-HRCT. METHODS This retrospective study included 38 consecutive patients with suspected coronary artery disease (CAD) who underwent CCTA with U-HRCT followed by invasive coronary angiography (ICA). Per-segment diameter stenosis was calculated. Diagnostic performance of CCTA relative to ICA as the reference standard was determined. For segments with >30% diameter stenosis, the correlation and agreement of percent diameter stenosis between CCTA and ICA were calculated. RESULTS Obstructive CAD was observed in 65 segments (12%) of 51 vessels (45%) in 32 patients (84%) during ICA. The per-patient, vessel, and segment analyses showed a sensitivity of 100% (95% confidence interval [CI], 95%-100%), 96% (95% CI: 89%-99%) and 95% (95% CI: 89%-98%), respectively, and a specificity of 67% (95% CI: 38%-67%), 81% (95% CI: 75%-83%) and 96% (95% CI: 96%-97%), respectively. The percentage of diameter stenosis, as determined by CCTA, demonstrated an excellent correlation with ICA (R = 0.90; 95% CI: 0.83-0.95) and a slight significant overestimation (mean: 4% ± 7%, p < .01), with the agreed range of limits being ± 16%. The median effective radiation dose for CCTA was 5.4 mSv (range: 2.9-18.0 mSv). CONCLUSIONS CCTA with U-HRCT demonstrated an excellent correlation and agreement with ICA in the quantification of coronary artery stenosis.
Collapse
Affiliation(s)
- Hidenobu Takagi
- Department of Radiology, Iwate Medical University, 19-1, Uchimaru, Morioka, Iwate, Japan.
| | - Ryoichi Tanaka
- Department of Radiology, Iwate Medical University, 19-1, Uchimaru, Morioka, Iwate, Japan.
| | - Kyohei Nagata
- Department of Cardiology, Iwate Medical University, 19-1, Uchimaru, Morioka, Iwate, Japan.
| | - Ryo Ninomiya
- Department of Cardiology, Iwate Medical University, 19-1, Uchimaru, Morioka, Iwate, Japan.
| | - Kazumasa Arakita
- Center for Medical Research and Development, Toshiba Medical Systems Corporation, 1385, Shimoishigami, Otawara, Japan.
| | - Joanne D Schuijf
- Center for Medical Research and Development Europe, Toshiba Medical Systems Europe, Zilverstraat 1, 2718 RP Zoetermeer, Netherlands.
| | - Kunihiro Yoshioka
- Department of Radiology, Iwate Medical University, 19-1, Uchimaru, Morioka, Iwate, Japan.
| |
Collapse
|
30
|
Ippolito D, Fior D, Franzesi CT, Riva L, Casiraghi A, Sironi S. Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality. LA RADIOLOGIA MEDICA 2017; 122:893-901. [PMID: 28849537 DOI: 10.1007/s11547-017-0800-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Accepted: 08/10/2017] [Indexed: 02/05/2023]
Abstract
BACKGROUND Effective radiation dose in coronary CT angiography (CTCA) for coronary artery bypass graft (CABG) evaluation is remarkably high because of long scan lengths. Prospective electrocardiographic gating with iterative reconstruction can reduce effective radiation dose. OBJECTIVES To evaluate the diagnostic performance of low-kV CT angiography protocol with prospective ecg-gating technique and iterative reconstruction (IR) algorithm in follow-up of CABG patients compared with standard retrospective protocol. METHODS Seventy-four non-obese patients with known coronary disease treated with artery bypass grafting were prospectively enrolled. All the patients underwent 256 MDCT (Brilliance iCT, Philips) CTCA using low-dose protocol (100 kV; 800 mAs; rotation time: 0.275 s) combined with prospective ECG-triggering acquisition and fourth-generation IR technique (iDose4; Philips); all the lengths of the bypass graft were included in the evaluation. A control group of 42 similar patients was evaluated with a standard retrospective ECG-gated CTCA (100 kV; 800 mAs).On both CT examinations, ROIs were placed to calculate standard deviation of pixel values and intra-vessel density. Diagnostic quality was also evaluated using a 4-point quality scale. RESULTS Despite the statistically significant reduction of radiation dose evaluated with DLP (study group mean DLP: 274 mGy cm; control group mean DLP: 1224 mGy cm; P value < 0.001). No statistical differences were found between PGA group and RGH group regarding intra-vessel density absolute values and SNR. Qualitative analysis, evaluated by two radiologists in "double blind", did not reveal any significant difference in diagnostic quality of the two groups. CONCLUSIONS The development of high-speed MDCT scans combined with modern IR allows an accurate evaluation of CABG with prospective ECG-gating protocols in a single breath hold, obtaining a significant reduction in radiation dose.
Collapse
Affiliation(s)
- Davide Ippolito
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy.
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy.
| | - Davide Fior
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Cammillo Talei Franzesi
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Luca Riva
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Alessandra Casiraghi
- Department of Diagnostic Radiology, "San Gerardo" Hospital, Via Pergolesi 33, 20900, Monza, MB, Italy
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
| | - Sandro Sironi
- School of Medicine, University of Milano-Bicocca, Via Cadore 48, 20900, Monza, MB, Italy
- Department of Diagnostic Radiology, "Papa Giovanni XXIII" Hospital, Bergamo, Italy
| |
Collapse
|
31
|
Kim J, Kwag HJ, Yoo SM, Yoo JY, Chae IH, Choi DJ, Park MJ, Vembar M, Chun EJ. Discrepancies between coronary CT angiography and invasive coronary angiography with focus on culprit lesions which cause future cardiac events. Eur Radiol 2017; 28:1356-1364. [DOI: 10.1007/s00330-017-5095-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2017] [Revised: 09/06/2017] [Accepted: 09/25/2017] [Indexed: 11/30/2022]
|
32
|
Patellar tracking after isolated medial patellofemoral ligament reconstruction: dynamic evaluation using computed tomography. Knee Surg Sports Traumatol Arthrosc 2017; 25:3197-3205. [PMID: 27544273 DOI: 10.1007/s00167-016-4284-x] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2015] [Accepted: 08/09/2016] [Indexed: 12/31/2022]
Abstract
PURPOSE Medial patellofemoral ligament (MPFL) reconstruction offers good clinical results with a very low rate of instability recurrence. However, its in vivo effect on patellar tracking is not clearly known. The aim of this study is to investigate the effects of MPFL reconstruction on patellar tracking using dynamic 320-detector-row CT. METHODS Ten patients with patellofemoral instability referred to isolated MPFL reconstruction surgery were selected and subjected to dynamic CT before and ≥6 months after surgery. Patellar tilt angles and shift distance were analysed using computer software specifically designed for this purpose. Kujala and Tegner scores were applied, and the radiation of the CTs was recorded. Two protocols for imaging acquisition were compared: a tube potential of 80 kV and 50 mA versus a tube potential of 120 kV and 100 mA, both with a slice thickness of 0.5 mm and an acquisition duration of 10 s. RESULTS There were no changes in patellar tracking after MPFL reconstruction. There was no instability relapse. Clinical scores improved from a mean of 51.9 (±15.6)-74.2 (±20.9) on the Kujala scale (p = 0.011) and from a median of 2 (range 0-4) to 4 (range 1-6) on the Tegner scale (p = 0.017). The imaging protocols produced a dose-length product (DLP) of 254 versus 1617 mGycm and a radiation effective estimated dose of 0.2 versus 1.3 mSv, respectively. Both protocols allowed the analysis of the studied parameters without loss of precision. CONCLUSIONS Reconstruction of the MPFL produced no improvement in patellar tilt or shift in the population studied. The low-radiation protocol was equally effective in measuring changes in patellar tracking and is recommended. Although the procedure successfully stabilized the patella, knee surgeons should not expect patellar shift and tilt correction when performing isolated patellofemoral ligament reconstruction in patients with recurrent patellar instability. LEVEL OF EVIDENCE IV.
Collapse
|
33
|
Nerlekar N, Ko BS, Nasis A, Cameron JD, Leung M, Brown AJ, Wong DTL, Ngu PJ, Troupis JM, Seneviratne SK. Impact of heart rate on diagnostic accuracy of second generation 320-detector computed tomography coronary angiography. Cardiovasc Diagn Ther 2017; 7:296-304. [PMID: 28567355 DOI: 10.21037/cdt.2017.03.05] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
OBJECTIVE To assess the impact of elevated heart rate (HR) on the diagnostic accuracy and image quality of second-generation 320-detector computed tomography coronary angiography (320-CTCA). METHODS Consecutive patients with suspected coronary disease referred for invasive coronary angiography (ICA) were prospectively recruited and underwent 320-CTCA. Pre-scan beta-blockers were administered if native HR>80 bpm and post-scan cohorts stratified by traditional (HR ≤60 bpm) and elevated HR (61-80 bpm). A wider phase window was used for the elevated HR group (30-80%). 320-CTCA and ICA were analyzed by independent readers blinded to other data. Significant disease was defined as ≥50% visual stenosis on ICA. Uninterpretable segments by 320-CTCA were considered to be significant on an intention-to-diagnose principle. Image quality was assessed by 5-point Likert score. RESULTS Of 107 patients studied (1,662 segments), there was no significant difference in sensitivity, specificity, positive and negative predictive value between patients with HR ≤60 bpm (n=55) vs. HR 61-80 bpm (n=52): 97%, 88%, 95%, 94% vs. 100%, 88%, 95%, 100%; Receiver operator characteristic-area under the curve 0.93 vs. 0.94, P=0.82). Overall per-patient diagnostic accuracy was 96% in both groups with no significant difference in interpretable segments (Likert ≥2) or median radiation dose (2.4 mSv vs. 2.7 mSv, P=0.35). Only 4/1,662 (0.2%) segments were uninterpretable by motion artefact in the whole cohort. CONCLUSIONS In patients with HR >60 and up to 80bpm, second generation 320-CTCA provides comparably adequate diagnostic accuracy to HR ≤60 without significantly impacting upon overall segmental evaluability.
Collapse
Affiliation(s)
- Nitesh Nerlekar
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia
| | - Brian S Ko
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia
| | - Arthur Nasis
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia
| | - James D Cameron
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia
| | - Michael Leung
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia
| | - Adam J Brown
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia
| | - Dennis T L Wong
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia
| | - Philip J Ngu
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia
| | - John M Troupis
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia.,Department of Diagnostic Imaging, MMC, Southern Health, Melbourne, Australia
| | - Sujith K Seneviratne
- Monash Cardiovascular Research Centre, Department of Medicine (Monash Medical Centre) Monash University and Monash Heart, Monash Health, 246 Clayton Road, Clayton, 3168 VIC, Australia
| |
Collapse
|
34
|
Contijoch F, Stayman JW, McVeigh ER. The impact of small motion on the visualization of coronary vessels and lesions in cardiac CT: A simulation study. Med Phys 2017; 44:3512-3524. [PMID: 28432820 DOI: 10.1002/mp.12295] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Revised: 02/27/2017] [Accepted: 04/16/2017] [Indexed: 12/14/2022] Open
Abstract
PURPOSE Coronary x-ray computed tomography angiography (CCTA) is used to non-invasively assess coronary artery geometry and has, combined with computational modeling, demonstrated the potential to identify physiologically significant lesions. These measurements require robust and accurate coronary imaging and delineation of vessels despite the presence of small motion. This simulation study characterizes the impact of small, uncorrected vessel drifts during data acquisition on the assessment of vessel intensity, diameter, and shape. METHODS We developed a digital phantom and simulated projection data for a clinical scanner geometry for a range of vessel drifts that can occur during relative vessel stasis (0 to 2 mm per 360° gantry rotation) for vessels between 0.2 and 3.0 mm in diameter (covering 0% through 93% stenosis of a 3 mm vessel). In addition to the impact of vessel drift, we evaluated the performance of half-scan acquisitions (relative to full-scans) over a range of gantry positions. The performance of FDK reconstructions was compared to an iterative technique and potential improvement in sampling from focal spot deflection and quarter detector offset was compared. RESULTS At rest, vessel intensity and diameter were accurately obtained in vessels greater than 1.5 mm with all vessels appearing circular in shape (major-to-minor axis ratio ~1). Vessels between 1.5 and 0.2 mm in diameter demonstrated a rapid decrease in signal intensity with full width half maximum (FWHM) vessel diameters remaining above 0.75 mm as true vessel diameter decreased. Uncorrected vessel motion resulted in decreased vessel intensity, increased vessel diameter, and distortion of vessel shape. The extent of these changes depended on both the position of the gantry as well as the reconstruction approach (half- vs. full-scan). FDK reconstruction results depended on choice of filter with Ram-Lak results yielding comparable performance to an unconstrained iterative reconstruction. Focal spot deflection and quarter detector offset did not result in large changes in performance, likely due to the high sampling density near the isocenter. CONCLUSIONS Despite improvement in gantry speed and acquisition of coronary images during cardiac phases that have relatively stationary vessels, small coronary drifts (0-2 mm per 360° rotation) have been reported and if uncorrected, can present challenges to visual grading and computational modeling of stenoses because vessels will appear dimmer, larger, and more ellipsoidal in shape. The impact of a particular motion depends on the gantry position, the use of half vs. full-scan acquisitions, and the reconstruction technique.
Collapse
Affiliation(s)
- Francisco Contijoch
- Department of Medicine, Division of Cardiology, UC San Diego School of Medicine, La Jolla, CA, 92123, USA
| | - J Webster Stayman
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Elliot R McVeigh
- Department of Medicine, Division of Cardiology, UC San Diego School of Medicine, La Jolla, CA, 92123, USA.,Department of Bioengineering, UC San Diego School of Engineering, La Jolla, CA, 92037-0412, USA.,Department of Radiology, UC San Diego School of Medicine, La Jolla, CA, 92123, USA
| |
Collapse
|
35
|
Yüceler Z, Kantarcı M, Tanboğa İH, Sade R, Kızrak Y, Pirimoğlu B, Bayraktutan Ü, Oğul H, Aksakal E. Coronary lesion complexity assessed by SYNTAX score in 256-slice dual-source MDCT angiography. Diagn Interv Radiol 2017; 22:334-40. [PMID: 27328718 DOI: 10.5152/dir.2015.15298] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE The SYNTAX Score (SS) has an important role in grading the complexity of coronary artery disease (CAD) in patients undergoing revascularization. Noninvasive determination of SS prior to invasive coronary angiography (ICA) might optimize patient management. We aimed to evaluate the agreement between ICA and multidetector computed tomography (MDCT) while testing the diagnostic effectiveness of SS-MDCT. METHODS Our study included 108 consecutive patients who underwent both MDCT angiography with a 256-slice dual-source MDCT system and ICA within 14±3 days. SS was calculated for both ICA and MDCT coronary angiography. Spearman's rank correlation coefficient was used to evaluate the association of SS-MDCT with SS-ICA, and Bland-Altman analysis was performed. RESULTS The degree of agreement between SS-ICA and SS-MDCT was moderate. The mean SS-MDCT was 14.5, whereas the mean SS-ICA was 15.9. After dividing SS into three groups (high [≥33], intermediate [23-32], and low [≤22] subgroups), agreement analysis was repeated. There was a significant correlation between SS-MDCT and SS-ICA in the low SS group (r=0.63, P = 0.043) but no significant correlation in the high SS group (r=0.036, P = 0.677). The inter-test agreement analysis showed at least moderate agreement, whereas thrombotic lesions and the type of bifurcation lesion showed fair agreement. CONCLUSION The calculation of SS-MDCT by adapting SS-ICA parameters achieved nearly the same degree of precision as SS-ICA and was better than SS-ICA, especially in the low SS group.
Collapse
Affiliation(s)
- Zeyneb Yüceler
- Department of Radiology, Ereğli State Hospital, Zonguldak, Turkey.
| | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Coronary Computed Tomography Angiography in Combination with Coronary Artery Calcium Scoring for the Preoperative Cardiac Evaluation of Liver Transplant Recipients. BIOMED RESEARCH INTERNATIONAL 2017; 2017:4081525. [PMID: 28164120 PMCID: PMC5259617 DOI: 10.1155/2017/4081525] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Revised: 12/07/2016] [Accepted: 12/18/2016] [Indexed: 02/08/2023]
Abstract
Liver transplantation is the best treatment option for early-stage hepatocellular carcinoma, liver cirrhosis, fulminant liver failure, and end-stage liver diseases. Even though advances in surgical techniques and perioperative care have improved postoperative outcomes, perioperative cardiovascular complications are a leading cause of postoperative morbidity and mortality following liver transplantation. Ischemic coronary artery disease (CAD) and cardiomyopathy are the most common cardiovascular diseases and could be negative predictors of postoperative outcomes in liver transplant recipients. Therefore, comprehensive cardiovascular evaluations are required to assess perioperative risks and prevent concomitant cardiovascular complications that would preclude good outcomes in liver transplant recipients. The two major types of cardiac computed tomography are the coronary artery calcium score (CACS) and coronary computed tomography angiography (CCTA). CCTA in combination with the CACS is a validated noninvasive alternative to coronary angiography for diagnosing and grading the severity of CAD. A CACS > 400 is associated with significant CAD and a known important predictor of posttransplant cardiovascular complications in liver transplant recipients. In this review article, we discuss the usefulness, advantages, and disadvantages of CCTA combined with CACS as a noninvasive diagnostic tool for preoperative cardiac evaluation and for maximizing the perioperative outcomes of liver transplant recipients.
Collapse
|
37
|
Lalude OO, Pugliese F, de Feyter PJ, Lerakis S. Complementary Imaging Techniques. Interv Cardiol 2016. [DOI: 10.1002/9781118983652.ch9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Affiliation(s)
| | | | | | - Stamatios Lerakis
- Emory University School of Medicine and Georgia Institute of Technology; Atlanta GA USA
| |
Collapse
|
38
|
Computed tomography versus invasive coronary angiography: design and methods of the pragmatic randomised multicentre DISCHARGE trial. Eur Radiol 2016; 27:2957-2968. [PMID: 27864607 DOI: 10.1007/s00330-016-4620-z] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2016] [Revised: 09/07/2016] [Accepted: 09/26/2016] [Indexed: 01/10/2023]
Abstract
OBJECTIVES More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninvasive test for detection and exclusion of coronary artery disease (CAD). To investigate the comparative effectiveness of CT and ICA, we designed the European pragmatic multicentre DISCHARGE trial funded by the 7th Framework Programme of the European Union (EC-GA 603266). METHODS In this trial, patients with a low-to-intermediate pretest probability (10-60 %) of suspected CAD and a clinical indication for ICA because of stable chest pain will be randomised in a 1-to-1 ratio to CT or ICA. CT and ICA findings guide subsequent management decisions by the local heart teams according to current evidence and European guidelines. RESULTS Major adverse cardiovascular events (MACE) defined as cardiovascular death, myocardial infarction and stroke as a composite endpoint will be the primary outcome measure. Secondary and other outcomes include cost-effectiveness, radiation exposure, health-related quality of life (HRQoL), socioeconomic status, lifestyle, adverse events related to CT/ICA, and gender differences. CONCLUSIONS The DISCHARGE trial will assess the comparative effectiveness of CT and ICA. KEY POINTS • Coronary artery disease (CAD) is a major cause of morbidity and mortality. • Invasive coronary angiography (ICA) is the reference standard for detection of CAD. • Noninvasive computed tomography angiography excludes CAD with high sensitivity. • CT may effectively reduce the approximately 2 million negative ICAs in Europe. • DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest probability for CAD.
Collapse
|
39
|
Chahal H, Levsky JM, Garcia MJ. Cardiac CT: present and future applications. BRITISH HEART JOURNAL 2016; 102:1840-1850. [DOI: 10.1136/heartjnl-2015-307481] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
40
|
Temporal averaging for analysis of four-dimensional whole-heart computed tomography perfusion of the myocardium: proof-of-concept study. Int J Cardiovasc Imaging 2016; 33:371-382. [PMID: 27832419 DOI: 10.1007/s10554-016-1011-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Accepted: 10/25/2016] [Indexed: 01/03/2023]
Abstract
To assess the feasibility of four-dimensional (4D) whole-heart computed tomography perfusion (CTP) of the myocardium and the added value of temporal averaging of consecutive 3D datasets from different heartbeats for analysis. We included 30 patients with suspected or known coronary artery disease (CAD) who underwent 320-row coronary CT angiography (CTA) and myocardial CTP. Out of these, 15 patients underwent magnetic resonance myocardial perfusion imaging (MR MPI). All CTP examinations were initiated after 3 min of intravenous infusion of adenosine (140 µg/kg/min) and were performed dynamically covering the entire heart every heart beat over a period of 20 ± 3 heart beats. Temporal averaging for dynamic CTP visualisation was analysed for the combination of two, three, four, six, and eight consecutive 3D datasets. Input time attenuation curves (TAC) were delivered from measurement points in the centre of the left ventricle. In all 30 patients, myocardial 4D CTP was feasible and temporal averaging was successfully implemented for all planned combinations of 3D datasets. Temporal averaging of three consecutive 3D datasets showed best performance in the analysis of all CTP image quality parameters: noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective image quality, and diagnostic accuracy with an improvement of SNR and CNR by a factor of 2.2 ± 1.3 and 1.3 ± 0.9. With increasing level of temporal averaging, the input TACs became smoother, but also shorter. Out of the 11 perfusion defects detected with MR MPI, 9 defects were also visible on the 4D CTP images. Whole-heart CTP of the myocardium is feasible and temporal averaging of dynamic datasets improves quantitative image quality parameters and visualization of perfusion defects while further studies are needed to assess its added value for quantification of perfusion parameters.
Collapse
|
41
|
Zeng D, Gong C, Bian Z, Huang J, Zhang X, Zhang H, Lu L, Niu S, Zhang Z, Liang Z, Feng Q, Chen W, Ma J. Robust dynamic myocardial perfusion CT deconvolution for accurate residue function estimation via adaptive-weighted tensor total variation regularization: a preclinical study. Phys Med Biol 2016; 61:8135-8156. [PMID: 27782004 DOI: 10.1088/0031-9155/61/22/8135] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Dynamic myocardial perfusion computed tomography (MPCT) is a promising technique for quick diagnosis and risk stratification of coronary artery disease. However, one major drawback of dynamic MPCT imaging is the heavy radiation dose to patients due to its dynamic image acquisition protocol. In this work, to address this issue, we present a robust dynamic MPCT deconvolution algorithm via adaptive-weighted tensor total variation (AwTTV) regularization for accurate residue function estimation with low-mA s data acquisitions. For simplicity, the presented method is termed 'MPD-AwTTV'. More specifically, the gains of the AwTTV regularization over the original tensor total variation regularization are from the anisotropic edge property of the sequential MPCT images. To minimize the associative objective function we propose an efficient iterative optimization strategy with fast convergence rate in the framework of an iterative shrinkage/thresholding algorithm. We validate and evaluate the presented algorithm using both digital XCAT phantom and preclinical porcine data. The preliminary experimental results have demonstrated that the presented MPD-AwTTV deconvolution algorithm can achieve remarkable gains in noise-induced artifact suppression, edge detail preservation, and accurate flow-scaled residue function and MPHM estimation as compared with the other existing deconvolution algorithms in digital phantom studies, and similar gains can be obtained in the porcine data experiment.
Collapse
Affiliation(s)
- Dong Zeng
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, People's Republic of China. Department of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People's Republic of China
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Dewey M, Rief M, Martus P, Kendziora B, Feger S, Dreger H, Priem S, Knebel F, Böhm M, Schlattmann P, Hamm B, Schönenberger E, Laule M, Zimmermann E. Evaluation of computed tomography in patients with atypical angina or chest pain clinically referred for invasive coronary angiography: randomised controlled trial. BMJ 2016; 355:i5441. [PMID: 27777234 PMCID: PMC5076567 DOI: 10.1136/bmj.i5441] [Citation(s) in RCA: 83] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
OBJECTIVE To evaluate whether invasive coronary angiography or computed tomography (CT) should be performed in patients clinically referred for coronary angiography with an intermediate probability of coronary artery disease. DESIGN Prospective randomised single centre trial. SETTING University hospital in Germany. PARTICIPANTS 340 patients with suspected coronary artery disease and a clinical indication for coronary angiography on the basis of atypical angina or chest pain. INTERVENTIONS 168 patients were randomised to CT and 172 to coronary angiography. After randomisation one patient declined CT and 10 patients declined coronary angiography, leaving 167 patients (88 women) and 162 patients (78 women) for analysis. Allocation could not be blinded, but blinded independent investigators assessed outcomes. MAIN OUTCOME MEASURE The primary outcome measure was major procedural complications within 48 hours of the last procedure related to CT or angiography. RESULTS Cardiac CT reduced the need for coronary angiography from 100% to 14% (95% confidence interval 9% to 20%, P<0.001) and was associated with a significantly greater diagnostic yield from coronary angiography: 75% (53% to 90%) v 15% (10% to 22%), P<0.001. Major procedural complications were uncommon (0.3%) and similar across groups. Minor procedural complications were less common in the CT group than in the coronary angiography group: 3.6% (1% to 8%) v 10.5% (6% to 16%), P=0.014. CT shortened the median length of stay in the angiography group from 52.9 hours (interquartile range 49.5-76.4 hours) to 30.0 hours (3.5-77.3 hours, P<0.001). Overall median exposure to radiation was similar between the CT and angiography groups: 5.0 mSv (interquartile range 4.2-8.7 mSv) v 6.4 mSv (3.4-10.7 mSv), P=0.45. After a median follow-up of 3.3 years, major adverse cardiovascular events had occurred in seven of 167 patients in the CT group (4.2%) and six of 162 (3.7%) in the coronary angiography group (adjusted hazard ratio 0.90, 95% confidence interval 0.30 to 2.69, P=0.86). 79% of patients stated that they would prefer CT for subsequent testing. The study was conducted at a University hospital in Germany and thus the performance of CT may be different in routine clinical practice. The prevalence was lower than expected, resulting in an underpowered study for the predefined primary outcome. CONCLUSIONS CT increased the diagnostic yield and was a safe gatekeeper for coronary angiography with no increase in long term events. The length of stay was shortened by 22.9 hours with CT, and patients preferred non-invasive testing.Trial registration ClinicalTrials.gov NCT00844220.
Collapse
Affiliation(s)
- Marc Dewey
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Matthias Rief
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Peter Martus
- Institute for Clinical Epidemiology and Applied Biometry, Tübingen, Germany
| | - Benjamin Kendziora
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Sarah Feger
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Henryk Dreger
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Sascha Priem
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Fabian Knebel
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Marko Böhm
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Peter Schlattmann
- Institute of Medical Statistics, Computer Sciences and Documentation, Jena, Germany
| | - Bernd Hamm
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Eva Schönenberger
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Michael Laule
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| | - Elke Zimmermann
- Charité-Universitätsmedizin Berlin, Humboldt-Universität and Freie Universität zu Berlin, Germany
| |
Collapse
|
43
|
Long B, Koyfman A. Best Clinical Practice: Current Controversies in Evaluation of Low-Risk Chest Pain-Part 1. J Emerg Med 2016; 51:668-676. [PMID: 27693075 DOI: 10.1016/j.jemermed.2016.07.103] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2015] [Revised: 07/20/2016] [Accepted: 07/21/2016] [Indexed: 10/20/2022]
Abstract
BACKGROUND Chest pain is a common presentation to the emergency department (ED), though the majority of patients are not diagnosed with acute coronary syndrome (ACS). Many patients are admitted to the hospital due to fear of ACS. OBJECTIVE Our aim was to investigate controversies in low-risk chest pain evaluation, including risk of missed ACS, stress test, and coronary computed tomography angiography (CCTA). DISCUSSION Chest pain accounts for 10 million ED visits in the United States annually. Many patients are at low risk for a major cardiac adverse event (MACE). With negative troponin and nonischemic electrocardiogram (ECG), the risk of MACE and myocardial infarction (MI) is < 1%. The American Heart Association recommends further evaluation in low- to intermediate-risk patients within 72 h. These modalities add little to further risk stratification. These evaluations do not appropriately risk stratify patients who are already at low risk, nor do they diagnose acute MI. CCTA is an anatomic evaluation of the coronary vasculature with literature support to decrease ED length of stay, though it is associated with downstream testing. Literature is controversial concerning further risk stratification in already low-risk patients. CONCLUSIONS With nonischemic ECG and negative cardiac biomarker, the risk of ACS approaches < 1%. Use of stress test and CCTA for risk stratification of low-risk chest pain patients is controversial. These tests may allow prognostication but do not predict ACS risk beyond ECG and troponin. CCTA may be useful for intermediate-risk patients, though further studies are required.
Collapse
Affiliation(s)
- Brit Long
- Department of Emergency Medicine, San Antonio Military Medical Center, Fort Sam Houston, Texas
| | - Alex Koyfman
- The University of Texas Southwestern Medical Center, Department of Emergency Medicine, Dallas, Texas
| |
Collapse
|
44
|
Evaluation of coronary stents using multidetector CT. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2016. [DOI: 10.1016/j.ejrnm.2016.05.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
45
|
Kaniewska M, Schuetz GM, Willun S, Schlattmann P, Dewey M. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis. Eur Radiol 2016; 27:1640-1659. [DOI: 10.1007/s00330-016-4513-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 05/02/2016] [Accepted: 07/18/2016] [Indexed: 01/06/2023]
|
46
|
Kühl JT, Hove JD, Kristensen TS, Norsk JB, Engstrøm T, Køber L, Kelbæk H, Kofoed KF. Coronary CT angiography in clinical triage of patients at high risk of coronary artery disease. SCAND CARDIOVASC J 2016; 51:28-34. [DOI: 10.1080/14017431.2016.1207799] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
47
|
Benz DC, Gräni C, Hirt Moch B, Mikulicic F, Vontobel J, Fuchs TA, Stehli J, Clerc OF, Possner M, Pazhenkottil AP, Gaemperli O, Buechel RR, Kaufmann PA. Minimized Radiation and Contrast Agent Exposure for Coronary Computed Tomography Angiography: First Clinical Experience on a Latest Generation 256-slice Scanner. Acad Radiol 2016; 23:1008-14. [PMID: 27174030 DOI: 10.1016/j.acra.2016.03.015] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Revised: 03/03/2016] [Accepted: 03/05/2016] [Indexed: 12/29/2022]
Abstract
RATIONALE AND OBJECTIVES The aim of the study was to evaluate the impact of the latest coronary computed tomography angiography (CCTA) techniques allowing a radiation- and contrast-sparing protocol on image quality in unselected patients referred for exclusion of suspected coronary artery disease (CAD). MATERIALS AND METHODS This prospective study was approved by the local ethics committee, and all patients provided written informed consent. Between March and June 2015, 89 consecutive patients (61% male; mean age 55 ± 11 years) referred for exclusion of CAD by 256-slice CCTA using prospective electrocardiogram triggering were included. Tube voltage (80-120 kVp), tube current (180-310 mA) as well contrast agent volume (25-45 mL) and flow rate (3.5-5 mL/s) were adapted to body mass index. Signal intensity was measured by placing a region of interest in the aortic root, the left main artery, and the proximal right coronary artery. Image noise was measured in the aortic root. Two independent blinded readers semi-quantitatively assessed the image quality regarding motion, noise, and contrast on a 4-point scale. RESULTS Median contrast agent volume and median effective radiation dose were 35 mL (interquartile range, 30-40 mL) and 0.5 mSv (interquartile range, 0.4-0.6 mSv), respectively. Mean attenuation in the aortic root was 412 ± 89 Hounsfield units. Diagnostic image quality was obtained in 1050 of 1067 (98.4%) coronary segments and, on an intention-to-diagnosis basis, in 85 of 89 (95.5%) patients. Below a cut-off heart rate of 67 beats/min, only 1 of 974 (0.1%) coronary segments was nondiagnostic. CONCLUSION A radiation- and contrast-sparing protocol for CCTA on a latest generation 256-slice computed tomography scanner yields diagnostic image quality in patients referred for CAD exclusion in daily clinical routine.
Collapse
|
48
|
Sandfort V, Ahlman MA, Jones EC, Selwaness M, Y Chen M, R Folio L, Bluemke DA. High pitch third generation dual-source CT: Coronary and cardiac visualization on routine chest CT. J Cardiovasc Comput Tomogr 2016; 10:282-8. [PMID: 27133589 PMCID: PMC4958576 DOI: 10.1016/j.jcct.2016.03.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 03/21/2016] [Accepted: 03/25/2016] [Indexed: 12/21/2022]
Abstract
BACKGROUND Chest CT scans are frequently performed in radiology departments but have not previously contained detailed depiction of cardiac structures. OBJECTIVES To evaluate myocardial and coronary visualization on high-pitch non-gated CT of the chest using 3rd generation dual-source computed tomography (CT). METHODS Cardiac anatomy of patients who had 3rd generation, non-gated high pitch contrast enhanced chest CT and who also had prior conventional (low pitch) chest CT as part of a chest abdomen pelvis exam was evaluated. Cardiac image features were scored by reviewers blinded to diagnosis and pitch. Paired analysis was performed. RESULTS 3862 coronary segments and 2220 cardiac structures were evaluated by two readers in 222 CT scans. Most patients (97.2%) had chest CT for oncologic evaluation. The median pitch was 2.34 (IQR 2.05, 2.65) in high pitch and 0.8 (IQR 0.8, 0.8) in low pitch scans (p < 0.001). High pitch CT showed higher image visualization scores for all cardiovascular structures compared with conventional pitch scans (p < 0.0001). Coronary arteries were visualized in 9 coronary segments per exam in high pitch scans versus 2 segments for conventional pitch (p < 0.0001). Radiation exposure was lower in the high pitch group compared with the conventional pitch group (median CTDIvol 10.83 vs. 12.36 mGy and DLP 790 vs. 827 mGycm respectively, p < 0.01 for both) with comparable image noise (p = 0.43). CONCLUSION Myocardial structure and coronary arteries are frequently visualized on non-gated 3rd generation chest CT. These results raise the question of whether the heart and coronary arteries should be routinely interpreted on routine chest CT that is otherwise obtained for non-cardiac indications.
Collapse
Affiliation(s)
- Veit Sandfort
- Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Mark A Ahlman
- Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Elizabeth C Jones
- Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Mariana Selwaness
- Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Marcus Y Chen
- Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - Les R Folio
- Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD, USA
| | - David A Bluemke
- Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD, USA.
| |
Collapse
|
49
|
Coronary in-stent restenosis: predisposing clinical and stent-related factors, diagnostic performance and analyses of inaccuracies in 320-row computed tomography angiography. Int J Cardiovasc Imaging 2016; 32 Suppl 1:105-15. [DOI: 10.1007/s10554-016-0872-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Accepted: 03/07/2016] [Indexed: 10/21/2022]
|
50
|
Feasibility of Selective Catheter-Directed Coronary Computed Tomography Angiography Using Ultralow-Dose Intracoronary Contrast Injection in a Swine Model. Invest Radiol 2016; 50:449-55. [PMID: 25816215 DOI: 10.1097/rli.0000000000000150] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE Selective catheter-directed intracoronary contrast injected coronary computed tomography angiography (selective CCTA) has recently been introduced for on-site evaluation of coronary artery disease during coronary artery catheterization. In this study, we aimed to develop a feasible protocol for selective CCTA using ultralow-dose contrast medium as compared with conventional intravenous CCTA (IV CCTA). MATERIALS AND METHODS A novel combined system incorporating coronary angiography and a 320-detector row computed tomographic scanner was used to study 4 swine (35-40 kg) under animal institutional review board approval. A selective CCTA scan was simultaneously performed with an injection of 13.13 mgI/mL of modulated contrast medium at multiple different injection rates including 2, 3, and 4 mL/s and different total injection volumes of either 20 or 30 mL. Intravenous CCTA was performed with 60 mL of contrast medium, followed by 30 mL of saline chaser at 5 mL/s. Coronary mean and peak intensity, transluminal attenuation gradient, as well as 3-dimensional maximum intensity projections were obtained. RESULTS Attenuation values (mean ± standard error, in Hounsfield units [HUs]) of selective CCTA for the left anterior descending (LAD) and right coronary artery (RCA) using the various combinations of injection rates and total injection volumes were as follows: 20 mL at 2 mL/s (LAD, 270.3 ± 20.4 HU; RCA, 322.6 ± 7.4 HU), 20 mL at 3 mL/s (LAD, 262.9 ± 20.4 HU; RCA, 264.7 ± 7.4 HU), 30 mL at 3 mL/s (LAD, 276.8 ± 20.4 HU; RCA, 274.0 ± 7.4 HU), 20 mL at 4 mL/s (LAD, 268.0 ± 20.4 HU; RCA, 277.7 ± 7.4 HU), and 30 mL at 4 mL/s (LAD, 251.3 ± 20.4 HU; RCA, 334.7 ± 7.4 HU). The representative protocol of the selective CCTA studies produced results within the optimal enhancement range (approximately 250-350 HU) for all segments, and comparison of transluminal attenuation gradient data with selective CCTA and IV CCTA studies demonstrated that the former method was more homogenous (-1.5245 and -1.7558 for LAD as well as 0.0459 and 0.0799 for RCA, respectively). Notably, the volume of iodine contrast medium used for selective CCTA was reported to be 1.09% (0.2 g) of IV CCTA (24 g). CONCLUSIONS The current findings demonstrate the feasibility of selective CCTA using ultralow-dose intracoronary contrast injection. This technique may provide additional means of coronary evaluation in patients who may require strategic planning before a procedure using a combined modality system.
Collapse
|