1
|
Loha T, Mukherjee K, Pal B. Prediction of bone ingrowth into a porous novel hip-stem: A finite element analysis integrated with mechanoregulatory algorithm. Proc Inst Mech Eng H 2024; 238:992-1004. [PMID: 39397723 DOI: 10.1177/09544119241286958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2024]
Abstract
Bone ingrowth into a porous implant is necessary for its long-term fixation. Although attempts have been made to quantify the peri-implant bone growth using finite element (FE) analysis integrated with mechanoregulatory algorithms, bone ingrowth into a porous cellular hip stem has scarcely been investigated. Using a three-dimensional (3D) FE model and mechanobiology-based numerical framework, the objective of this study was to predict the spatial distribution of evolutionary bone ingrowth into an uncemented novel porous hip stem proposed earlier by the authors. A CT-based FE macromodel of the implant-bone structure was developed. The bone material properties were assigned based on CT grey value. Peak musculoskeletal loading conditions, corresponding to level walking and stair climbing, were applied. The geometry of the implant-bone macromodel was divided into multiple submodels. A suitable mapping framework was used to transfer maximum nodal displacements from the FE macromodel to the cut boundaries of the FE submodels. CT grey value-based bone materials properties were assigned to the submodels. Thereafter, the submodels were solved and simulations of bone ingrowth were carried out using mechanoregulatory principle. A gradual increase in the average Young's modulus, from 1200 to 1500 MPa, of the bone tissue layer was observed considering all the submodels. The distal submodel exhibited 82% of bone ingrowth, whereas the proximal submodel experienced 65% bone ingrowth. Equilibrium in the bone ingrowth process was achieved in 7 weeks postoperatively, with a notable amount of bone ingrowth that should lead to biological fixation of the novel hip stem.
Collapse
Affiliation(s)
- Tanmoy Loha
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal, India
| | - Kaushik Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology, Delhi, Delhi, India
| | - Bidyut Pal
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal, India
| |
Collapse
|
2
|
Kiritopoulos D, Nyström A, Hailer NP, Mallmin H, Lazarinis S. Continuous periprosthetic bone loss around the TOP ® cup and inferior survival rate at an 8-year follow-up: a prospective cohort study. BMC Musculoskelet Disord 2024; 25:741. [PMID: 39285412 PMCID: PMC11403771 DOI: 10.1186/s12891-024-07865-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 09/09/2024] [Indexed: 09/22/2024] Open
Abstract
BACKGROUND The trabeculae-oriented pattern (TOP®) cup was designed to minimize acetabular periprosthetic bone loss. In our previous prospective study comprising 30 patients with a two-year follow-up we found a substantial decrease in periprosthetic bone mineral density (pBMD) in the proximal and medial regions of the TOP cup. The present study aims to investigate pBMD changes in the mid-term and how this affects implant survival. METHODS We followed the previous cohort and estimated implant survival by Kaplan-Meier analysis, evaluated pBMD with dual-energy X-ray absorptiometry (DXA) and clinical outcome using the Harris Hip Score (HHS). RESULTS Mean follow-up was 8.6 (range 7.8-9.1) years. The eight-year implant survival rate for cup revision for all reasons was 83% (95% confidence interval {CI}: 70-97) and 86% (CI: 74-99) when cup revision due to aseptic loosening was the endpoint. Mean HHS at eight years was 95 (range 77-100). A further 12% (CI: 5-17) loss in pBMD was detected in the proximal Digas zone 1 and 12% (CI: 7-17) loss in Digas zone 2 also between two and eight years after surgery. pBMD continued to decrease up to 30% (CI: 24-36) in Digas zones 1, 2 and 3 compared to pBMD immediately postoperatively. CONCLUSIONS The TOP cup shows inferior mid-term survival rates compared to other uncemented cups, as well as a continuous decrease in pBMD. Periprosthetic bone loss cannot be prevented by this uncemented cup. CLINICAL TRIAL NUMBER Not applicable.
Collapse
Affiliation(s)
- Demostenis Kiritopoulos
- Department of Surgical Sciences, Section of Orthopedics, Uppsala University, Uppsala, Sweden.
| | - Andreas Nyström
- Department of Surgical Sciences, Section of Orthopedics, Uppsala University, Uppsala, Sweden
| | - Nils P Hailer
- Department of Surgical Sciences, Section of Orthopedics, Uppsala University, Uppsala, Sweden
| | - Hans Mallmin
- Department of Surgical Sciences, Section of Orthopedics, Uppsala University, Uppsala, Sweden
| | - Stergios Lazarinis
- Department of Surgical Sciences, Section of Orthopedics, Uppsala University, Uppsala, Sweden
| |
Collapse
|
3
|
Nimmal Haribabu G, Basu B. Implementing Machine Learning approaches for accelerated prediction of bone strain in acetabulum of a hip joint. J Mech Behav Biomed Mater 2024; 153:106495. [PMID: 38460455 DOI: 10.1016/j.jmbbm.2024.106495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/10/2024] [Accepted: 03/01/2024] [Indexed: 03/11/2024]
Abstract
The Finite Element (FE) methods for biomechanical analysis involving implant design and subject parameters for musculoskeletal applications are extensively reported in literature. Such an approach is manually intensive and computationally expensive with longer simulations times. Although Artificial Intelligence (AI) based approaches are implemented to a limited extent in biomechanics, such approaches to predict bone strain in acetabulum of a hip joint, are hardly explored. In this context, the primary objective of this paper is to evaluate machine learning (ML) models in tandem with high-fidelity FEA data for the accelerated prediction of the biomechanical response in the acetabulum of the human hip joint, during the walking gait. The parameters used in the FEA study included the subject weight, number and distribution of fins on the periphery of the acetabular shell, bone condition and phases of the gait cycle. The biomechanical response has also been evaluated using three different acetabular liners, including pre-clinically validated HDPE-20% HA-20% Al2O3, highly-crosslinked ultrahigh molecular weight polyethylene (HC-UHMWPE) and ZrO2-toughened Al2O3 (ZTA). Such parametric variation in FEA analysis, involving 26 variables and a full factorial design resulted in 10,752 datasets for spatially varying bone strains. The bone condition, as opposed to subject weight, was found to play a statistically significant role in determining the strain response in the periprosthetic bone of the acetabulum. While utilising hyperparameter tuning, K-fold cross validation and statistical learning approaches, a number of ML models were trained on the FEA dataset, and the Random Forest model performed the best with a coefficient of determination (R2) value of 0.99/0.97 and Root Mean Square Error (RMSE) of 0.02/0.01 on the training/test dataset. Taken together, this study establishes the potential of ML approach as a fast surrogate of FEA for implant biomechanics analysis, in less than a minute.
Collapse
Affiliation(s)
- Gowtham Nimmal Haribabu
- Laboratory for Biomaterials Science and Translational Research, Materials Research Centre, Indian Institute of Science, Bangalore, 560012, India
| | - Bikramjit Basu
- Laboratory for Biomaterials Science and Translational Research, Materials Research Centre, Indian Institute of Science, Bangalore, 560012, India.
| |
Collapse
|
4
|
Mondal S, MacManus DB, Ghosh R, Banagunde A, Dunne N. A numerical investigation of stress, strain, and bone density changes due to bone remodelling in the talus bone following total ankle arthroplasty. J Med Eng Technol 2024; 48:1-11. [PMID: 38864409 DOI: 10.1080/03091902.2024.2355319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 05/08/2024] [Indexed: 06/13/2024]
Abstract
Total ankle arthroplasty is the gold standard surgical treatment for severe ankle arthritis and fracture. However, revision surgeries due to the in vivo failure of the ankle implant are a serious concern. Extreme bone density loss due to bone remodelling is one of the main reasons for in situ implant loosening, with aseptic loosening of the talar component being one of the primary reasons for total ankle arthroplasty revisions. This study is aimed at determining the performance and potential causes of failure of the talar component. Herein, we investigated the stress, strain, and bone density changes that take place in the talus bone during the first 6 months of bone remodelling due to the total ankle arthroplasty procedure. Computed tomography scans were used to generate the 3D geometry used in the finite element (FE) model of the Intact and implanted ankle. The Scandinavian Total Ankle Replacement (STAR™) CAD files were generated, and virtual placement within bone models was done following surgical guidelines. The dorsiflexion physiological loading condition was investigated. The cortical region of the talus bone was found to demonstrate the highest values of stress (5.02 MPa). Next, the adaptive bone remodelling theory was used to predict bone density changes over the initial 6-month post-surgery. A significant change in bone density was observed in the talus bone due to bone remodelling. The observed quantitative changes in talus bone density over 6-month period underscore potential implications for implant stability and fracture susceptibility. These findings emphasise the importance of considering such biomechanical factors in ankle implant design and clinical management.
Collapse
Affiliation(s)
- Subrata Mondal
- Mechanical Engineering Department, University of Bath, United Kingdom
| | - David B MacManus
- School of Mechanical and Materials Engineering, University College Dublin, Ireland
| | - Rajesh Ghosh
- School of Engineering, Indian Institute of Technology, Mandi, Himachal Pradesh, India
| | - Abhishek Banagunde
- Powertrain Durability Mahindra and Mahindra Ltd, Mahindra World City, Chennai, Tamilnadu, India
| | - Nicholas Dunne
- School of Mechanical and Manufacturing Engineering, Dublin City University, Ireland
- Centre for Medical Engineering Research, Dublin City University, Ireland
- School of Pharmacy, Queen's University Belfast, Belfast, United Kingdom
- Department of Mechanical and Manufacturing Engineering, School of Engineering, Trinity College Dublin, Ireland
- Advanced Manufacturing Research Centre (I-Form), School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin 9, Ireland
- Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Dublin 2, Ireland
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland
- Advanced Processing Technology Research Centre, Dublin City University, Dublin 9, Ireland
- Biodesign Europe, Dublin City University, Dublin 9, Ireland
| |
Collapse
|
5
|
Talukdar RG, Saviour CM, Dhara S, Gupta S. Biomechanical analysis of functionally graded porous interbody cage for lumbar spinal fusion. Comput Biol Med 2023; 164:107281. [PMID: 37481948 DOI: 10.1016/j.compbiomed.2023.107281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 06/28/2023] [Accepted: 07/16/2023] [Indexed: 07/25/2023]
Abstract
Functionally graded porous (FGP) interbody cage might offer a trade-off between porosity-based reduction of stiffness and mechanical properties. Using finite element models of intact and implanted lumbar functional spinal unit (FSU), the study investigated the quantitative deviations in load transfer and adaptive changes in bone density distributions around FGP interbody cages. The cage had three graded porosities: FGP-A, -B, and -C corresponded to a maximum porosity levels of 48%, 65% and 78%, respectively. Efficacy of the FGP cages were evaluated by comparing the numerically predicted results of solid-Ti and uniformly porous 78% porosity (P78) cage. Variations in stiffness and interface condition affected the strain distribution and bone remodelling around the cages. Peak strains of 0.5-1% were observed in less number of peri-prosthetic bone elements for the FGP cages as compared to the solid-Ti cage. Strains and bone apposition were considerably higher for the bonded implant-bone interface condition than the debonded case. For the FGP-C with bonded interface condition, bone apposition of 11-20% was predicted in the L4 and L5 regions of interest (ROIs); whereas the debonded model exhibited 6-10% increase in bone density. The deviations in bone density change between FGP-C and P78 model were 3-8% for L4 and L5 ROIs. FGP resulted in a reduced average micromotion (∼70-106 μm) as compared to solid-Ti (116 μm), for all physiologic movements. Compared to solid-Ti and uniformly porous cages, the FGP cage seems to be a viable alternative considering the conflicting nature of strength and porosity.
Collapse
Affiliation(s)
- Rahul Gautam Talukdar
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur, 721 302, West Bengal, India
| | - Ceby Mullakkara Saviour
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721 302, West Bengal, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur, 721 302, West Bengal, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721 302, West Bengal, India.
| |
Collapse
|
6
|
Saviour CM, Gupta S. Design of a functionally graded porous uncemented acetabular component: Influence of polar gradation. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023:e3709. [PMID: 37089063 DOI: 10.1002/cnm.3709] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 02/14/2023] [Accepted: 04/05/2023] [Indexed: 05/03/2023]
Abstract
The functionally graded porous metal-backed (FGPMB) acetabular component has the potential to minimize strain-shielding induced bone resorption, caused by stiffness mismatch of implant and host bone. This study is aimed at a novel design of FGPMB acetabular component, which is based on numerical investigations of the mechanical behavior of acetabular components with regard to common failure scenarios, considering various daily activities and implant-bone interface conditions. Both radial and polar functional gradations were implemented, and the effects of the polar gradation exponent on the failure criteria were evaluated. The relationships between porosity and orthotropic mechanical properties of a tetrahedron-based unit cell were obtained using a numerical homogenization method. Strain-shielding in cancellous bone was relatively lesser for the FGPMB than solid metal-backing. Few nodes around the rim were susceptible to implant-bone interfacial debonding, irrespective of the polar gradation exponent. Although the most favorable bone remodeling predictions were obtained for a polar gradation exponent of 0.1, a sudden change in the porosity was observed near the rim of FGPMB. Bone remodeling patterns were similar for polar gradation exponent of 5.0 and solid metal-backing. Moreover, the volumetric wear was maximum and minimum for polar gradation exponents of 0.1 and 5, respectively. Furthermore, the micromotions of different polar gradation exponents were within a range (20-40 μm) that might facilitate bone ingrowth. Considering common failure mechanisms, the FGPMB having polar gradation exponents in the range of 0.1-0.5 appeared to be a viable alternative to the solid acetabular component, within which a gradation exponent of 0.25 seemed the most appropriate design parameter.
Collapse
Affiliation(s)
- Ceby Mullakkara Saviour
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| |
Collapse
|
7
|
Ghosh R, Chanda S, Chakraborty D. Application of finite element analysis to tissue differentiation and bone remodelling approaches and their use in design optimization of orthopaedic implants: A review. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3637. [PMID: 35875869 DOI: 10.1002/cnm.3637] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 06/26/2022] [Accepted: 07/21/2022] [Indexed: 06/15/2023]
Abstract
Post-operative bone growth and long-term bone adaptation around the orthopaedic implants are simulated using the mechanoregulation based tissue-differentiation and adaptive bone remodelling algorithms, respectively. The primary objective of these algorithms was to assess biomechanical feasibility and reliability of orthopaedic implants. This article aims to offer a comprehensive review of the developments in mathematical models of tissue-differentiation and bone adaptation and their applications in studies involving design optimization of orthopaedic implants over three decades. Despite the different mechanoregulatory models developed, existing literature confirm that none of the models can be highly regarded or completely disregarded over each other. Not much development in mathematical formulations has been observed from the current state of knowledge due to the lack of in vivo studies involving clinically relevant animal models, which further retarded the development of such models to use in translational research at a fast pace. Future investigations involving artificial intelligence (AI), soft-computing techniques and combined tissue-differentiation and bone-adaptation studies involving animal subjects for model verification are needed to formulate more sophisticated mathematical models to enhance the accuracy of pre-clinical testing of orthopaedic implants.
Collapse
Affiliation(s)
- Rajdeep Ghosh
- Composite Structures and Fracture Mechanics Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam, India
| | - Souptick Chanda
- Biomechanics and Simulations Laboratory, Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam, India
- Mehta Family School of Data Science and Artificial Intelligence, Indian Institute of Technology Guwahati, Guwahati, Assam, India
| | - Debabrata Chakraborty
- Composite Structures and Fracture Mechanics Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam, India
| |
Collapse
|
8
|
Jyoti, Mondal S, Ghosh R. Biomechanical analysis of three popular tibial designs for TAR with different implant-bone interfacial conditions and bone qualities: A finite element study. Med Eng Phys 2022; 104:103812. [DOI: 10.1016/j.medengphy.2022.103812] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 03/10/2022] [Accepted: 04/25/2022] [Indexed: 11/25/2022]
|
9
|
Talukdar RG, Saviour CM, Tiwarekar K, Dhara S, Gupta S. Bone Remodelling Around Solid and Porous Interbody Cages in the Lumbar Spine. J Biomech Eng 2022; 144:1140536. [PMID: 35484999 DOI: 10.1115/1.4054457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Indexed: 11/08/2022]
Abstract
Spinal fusion is an effective surgical treatment for intervertebral disc degeneration. However, the consequences of implantation with interbody cages on load transfer and bone remodelling in the vertebral bodies has scarcely been investigated. Using detailed 3D models of an intact and implanted lumbar spine and the strain energy density based bone remodelling algorithm, this study investigated the evolutionary changes in bone density distributions around porous and solid interbody cages. Follower load technique and submodelling approach were employed to simulate applied loading conditions on the lumbar spine models. The study determined the relationship between mechanical properties and parametrical characteristics of porous Body-centered-cubic (BCC) models, which corroborated well with Gibson-Ashby and exponential regression models. Variations in porosity affected the peri-prosthetic stress distributions and bone remodelling around the cages. In comparison to the solid cage, stresses and strains in the cancellous bone decreased with an increase in cage porosity; whereas the range of motion increased. For the solid cage, increase in bone density of 20-28% was predicted in the L4 inferior and L5 superior regions; whereas the model with 78% porosity exhibited a small 3-5% change in bone density. An overall increase of 9-14% bone density was predicted in the L4 and L5 vertebrae after remodelling for solid interbody cages, which may influence disc degeneration in the adjacent segment. In comparison to the solid cage, an interbody cage with 65-78% porosity could be a viable and promising alternative, provided sufficient mechanical strength is offered.
Collapse
Affiliation(s)
- Rahul Gautam Talukdar
- Advanced Technology and Development Centre, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Ceby Mullakkara Saviour
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Kaustubh Tiwarekar
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Sanjay Gupta
- Advanced Technology and Development Centre, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India; Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| |
Collapse
|
10
|
[Biomechanical analysis and effectiveness evaluation of zone Ⅰ+ Ⅱ+ Ⅲ reconstruction of hemipelvis with rod-screw prosthesis]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2022; 36:431-438. [PMID: 35426282 PMCID: PMC9011076 DOI: 10.7507/1002-1892.202110018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
OBJECTIVE To analyze the biomechanical properties of the rod-screw prosthesis based on a pelvic three-dimensional finite element model including muscle and ligament, and evaluate the effectiveness of zoneⅠ+Ⅱ+Ⅲ reconstruction of hemipelvis with rod-screw prosthesis in combination with clinical applications. METHODS A total of 21 patients who underwent hemipelvic tumor resection (zoneⅠ+Ⅱ+Ⅲ) and rod-screw prosthesis reconstruction between January 2015 and December 2020 were selected as the research subjects. Among them, there were 11 males and 10 females; the age ranged from 16 to 64 years, with an average age of 39.2 years. There were 9 cases of chondrosarcoma, 7 cases of osteosarcoma, 3 cases of Ewing sarcoma, and 2 cases of undifferentiated pleomorphic sarcoma. According to the Musculoskeletal Tumor Society Score (MSTS) staging, there were 19 cases of stage ⅡB and 2 cases of stage Ⅲ. Preoperative Harris Hip Score (HHS) and MSTS score were 54.4±3.1 and 14.1±2.0, respectively. Intraoperative 15 cases underwent extensive resection, 5 cases underwent marginal resection, and 1 case underwent intralesional resection. The CT image of 1 patient after reconstruction was used to establish a three-dimensional solid model of the pelvis via Mimics23Suite and 3-matic softwares. At the same time, a mirror operation was used to obtain a normal pelvis model, then the two solid models were imported into the finite element analysis software Workbench 2020R1 to establish three-dimensional finite element models, and the biomechanical properties of the standing position were analyzed. The operation time, intraoperative blood loss, and operation-related complications were recorded, and the postoperative evaluation was carried out with HHS and MSTS scores. Finally, the local recurrence and metastasis were reviewed. RESULTS Finite element analysis showed that the peak stress of the reconstructed pelvis appeared at the fixed S1, 2 rod-screw connections; the peak stress without muscles was higher than that after muscle construction, but much smaller than the yield strength of titanium alloy. The operation time was 250-370 minutes, with an average of 297 minutes; the amount of intraoperative blood loss was 3 200-5 500 mL, with an average of 4 009 mL. All patients were followed up 8-72 months, with an average of 42 months. There were 7 cases of pulmonary metastasis, of which 2 cases were preoperative metastasis; 5 cases died, 16 cases survived, and the 5-year survival rate was 72.1%. There were 3 cases of local recurrence, all of whom did not achieve extensive resection during operation. The function of the affected limbs significantly improved, and the walking function was restored. The HHS and MSTS scores were 75.2±3.0 and 20.4±2.0 at last follow-up, respectively, and the differences were significant when compared with those before operation (t=22.205, P<0.001; t=11.915, P<0.001). During follow-up, 2 cases of delayed incision healing, 2 cases of deep infection, 1 case of screw loosening, and 1 case of prosthesis dislocation occurred, and no other complication such as prosthesis or screw fracture occurred. CONCLUSION The stress and deformation distribution of the reconstructed pelvis are basically the same as normal pelvis. The rod-screw prosthesis is an effective reconstruction method for pelvic malignant tumors.
Collapse
|
11
|
Hadizadeh H, Hadizadeh H, Ganjiani M, Karimpour M, Hosseinpour A. Investigation of the effect of the angle between femoral and prosthesis mechanical axes on bone remodeling of femur in total knee arthroplasty. Proc Inst Mech Eng H 2021; 235:976-984. [PMID: 33985375 DOI: 10.1177/09544119211016128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The bone remodeling is the process in which the bone adapts its structure to the variation of environmental loads. The joint might be broken or damaged as a result of aging or an accident. To remedy this situation, Total Knee Arthroplasty (TKA) and prosthesis implantation is recommended. The main goal of this research is to investigate the effects of femur implanting angle on the bone remodeling process after TKA in the Coronal, Sagittal and horizontal planes over seven years. First, the 3D CAD model from CT images is created then the bone behavior is simulated using a model with a USDFLD subroutine. The results show that as the implant rotates in one direction, the stress and density distribution increases in the same direction whereas the load and consequently the bone density decrease substantially in the opposite direction. Consequently, the bone density might even decrease 77 and 31 percent in the coronal and sagittal plane respectively, so in the total knee arthroplasty, the mechanical axes of prosthesis and femur should be parallel. The active bone which occurs as a result of mechanical axes of prosthesis and femur parallelism and consequently uniform load distribution, can protect the implant from prosthesis loosening and fracture.
Collapse
Affiliation(s)
- Hasan Hadizadeh
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Hossein Hadizadeh
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Mehdi Ganjiani
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Morad Karimpour
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Abolfazl Hosseinpour
- Department of Mechanical Engineering, University of North Carolina, Charlotte, NC, USA
| |
Collapse
|
12
|
Chatterjee S, Roy S, Majumder S, RoyChowdhury A. Biomechanical Analysis to Probe Role of Bone Condition and Subject Weight in Stiffness Customization of Femoral Stem for Improved Periprosthetic Biomechanical Response. J Biomech Eng 2020; 142:101002. [PMID: 32320044 DOI: 10.1115/1.4046973] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Indexed: 11/08/2022]
Abstract
Stress shielding due to difference in stiffness of bone and implant material is one among the foremost causes of loosening and failure of load-bearing implants. Thus far, femoral geometry has been given priority for the customization of total hip joint replacement (THR) implant design. This study, for the first time, demonstrates the key role of bone condition and subject-weight on the customization of stiffness and design of the femoral stem. In particular, internal hollowness was incorporated to reduce the implant stiffness and such designed structure has been customized based on subject parameters, including bone condition and bodyweight. The primary aim was to tailor these parameters to achieve close to natural strain distribution at periprosthetic bone and to reduce interfacial bone loss over time. The maintenance of interfacial bone density over time has been studied here through analysis of bone remodeling (BR). For normal bodyweight, the highest hollowness exhibited clinically relevant biomechanical response, for all bone conditions. However, for heavier subjects, consideration of bone quality was found to be essential as higher hollowness induced bone failure in weaker bones and implant failure in stronger bones. Moreover, for stronger bone, thinner medial wall was found to reduce bone resorption over time on the proximo-lateral zone of stress shielding, while lateral thinning was found advantageous for weaker bones. The findings of this study are likely to facilitate designing of femoral stems for achieving better physiological outcomes and enhancement of the quality of life of patients undergoing THR surgery.
Collapse
Affiliation(s)
- Subhomoy Chatterjee
- Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Howrah, West Bengal 711103, India; Materials Research Centre, Indian Institute of Science, Bangalore, Karnataka 560012, India
| | - Sandipan Roy
- Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Howrah, West Bengal 711103, India; Department of Mechanical Engineering, SRM Institute of Science & Technology, Kattankulathur, Kancheepuram, Chennai, Tamil Nadu 603203, India
| | - Santanu Majumder
- Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal 711103, India
| | - Amit RoyChowdhury
- Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal 711103, India
| |
Collapse
|
13
|
Kumar A, Ghosh R, Kumar R. Effects of interfacial crack and implant material on mixed-mode stress intensity factor and prediction of interface failure of cemented acetabular cup. J Biomed Mater Res B Appl Biomater 2019; 108:1844-1856. [PMID: 31769210 DOI: 10.1002/jbm.b.34526] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2019] [Revised: 10/11/2019] [Accepted: 11/09/2019] [Indexed: 11/12/2022]
Abstract
This study deals with the effects of interfacial crack and implant material on mixed-mode stress intensity factor and prediction of interface failure of the cemented acetabular cup. A three dimensional (3D) finite element (FE) model of implanted pelvic bone was developed based on the computed tomography (CT) scan data. Combinations of four materials were considered for implant material. To understand the influence of interfacial crack at bone-cement and cement-implant interfaces on failure, 2D cracked models were developed based on the FE model and solved using the element-free Galerkin method (EFGM) by considering a rectangular section in the superior, inferior, anterior, and posterior locations. Interface failure was predicted in terms of mixed-mode stress intensity factor (SIF). The stress values obtained from FE analysis were transferred at the cut boundary of the rectangular section and considered as a mixed-mode loading condition to determine the SIF in the superior, inferior, anterior, and posterior locations at bone-cement and cement-implant interfaces using EFGM. Location wise, anterior seems to have more chances of failure because SIF in the anterior location was found to be higher than other locations. The bone-cement interface has more SIF and indicated more chances of failure than the cement-implant interface. Less SIF was found for the ceramic-ceramic material combination than other material combinations.
Collapse
Affiliation(s)
- Ajay Kumar
- School of Engineering, Indian Institute of Technology Mandi, Kamand, Himachal Pradesh, India
| | - Rajesh Ghosh
- School of Engineering, Indian Institute of Technology Mandi, Kamand, Himachal Pradesh, India
| | - Rajeev Kumar
- School of Engineering, Indian Institute of Technology Mandi, Kamand, Himachal Pradesh, India
| |
Collapse
|
14
|
Chatterjee S, Kobylinski S, Basu B. Finite Element Analysis to Probe the Influence of Acetabular Shell Design, Liner Material, and Subject Parameters on Biomechanical Response in Periprosthetic Bone. J Biomech Eng 2019; 140:2681672. [PMID: 30029239 DOI: 10.1115/1.4040249] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Indexed: 11/08/2022]
Abstract
The implant stability and biomechanical response of periprosthetic bone in acetabulum around total hip joint replacement (THR) devices depend on a host of parameters, including design of articulating materials, gait cycle and subject parameters. In this study, the impact of shell design (conventional, finned, spiked, and combined design) and liner material on the biomechanical response of periprosthetic bone has been analyzed using finite element (FE) method. Two different liner materials: high density polyethylene-20% hydroxyapatite-20% alumina (HDPE-20%HA-20%Al2O3) and highly cross-linked ultrahigh molecular weight polyethylene (HC-UHMWPE) were used. The subject parameters included bone condition and bodyweight. Physiologically relevant load cases of a gait cycle were considered. The deviation of mechanical condition of the periprosthetic bone due to implantation was least for the finned shell design. No significant deviation was observed at the bone region adjacent to the spikes and the fins. This study recommends the use of the finned design, particularly for weaker bone conditions. For stronger bones, the combined design may also be recommended for higher stability. The use of HC-UHMWPE liner was found to be better for convensional shell design. However, similar biomechanical response was captured in our FE analysis for both the liner materials in case of other shell designs. Overall, the study establishes the biomechanical response of periprosthetic bone in the acetabular with preclinically tested liner materials together with new shell design for different subject conditions.
Collapse
Affiliation(s)
- Subhomoy Chatterjee
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India
| | - Sabine Kobylinski
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Centre for BioSystems and Engineering, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Technical University of Applied Sciences Regensburg (OTH Regensburg), Regensburg 93047, Germany
| | - Bikramjit Basu
- Materials Research Centre, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Translational Center on Biomaterials for Orthopaedic and Dental Applications, Indian Institute of Science, Bengaluru 560012, Karnataka, India; Centre for BioSystems and Engineering, Indian Institute of Science, Bengaluru 560012, Karnataka, India e-mails:
| |
Collapse
|
15
|
Mondal S, Ghosh R. Bone remodelling around the tibia due to total ankle replacement: effects of implant material and implant-bone interfacial conditions. Comput Methods Biomech Biomed Engin 2019; 22:1247-1257. [PMID: 31497997 DOI: 10.1080/10255842.2019.1661385] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
One of the major causes of implant loosening is due to excessive bone resorption surrounding the implant due to bone remodelling. The objective of the study is to investigate the effects of implant material and implant-bone interface conditions on bone remodelling around tibia bone due to total ankle replacement. Finite element models of intact and implanted ankles were developed using CT scan data sets. Bone remodelling algorithm was used in combination with FE analysis to predict the bone density changes around the ankle joint. Dorsiflexion, neutral, and plantar flexion positions were considered, along with muscle force and ligaments. Implant-bone interfacial conditions were assumed as debonded and bonded to represent non-osseointegration and fully osseointegration at the porous coated surface of the implant. To investigate the effect of implant material, three finite element models having different material combinations of the implant were developed. For model 1, tibial and talar components were made of Co-Cr-Mo, and meniscal bearing was made of UHMWPE. For model 2, tibial and talar components were made of ceramic and meniscal bearing was made of UHMWPE. For model 3, tibial and talar components were made of ceramic and meniscal bearing was made of CFR-PEEK. Changes in implant material showed no significant changes in bone density due to bone remodelling. Therefore, ceramic appears to be a viable alternative to metal and CFR-PEEK can be used in place of UHMWPE. This study also indicates that proper bonding between implant and bone is essential for long-term survival of the prosthetic components.
Collapse
Affiliation(s)
- Subrata Mondal
- School of Engineering, Indian Institute of Technology Mandi , Mandi , India
| | - Rajesh Ghosh
- School of Engineering, Indian Institute of Technology Mandi , Mandi , India
| |
Collapse
|
16
|
Kumar A, Shitole P, Ghosh R, Kumar R, Gupta A. Experimental and numerical comparisons between finite element method, element-free Galerkin method, and extended finite element method predicted stress intensity factor and energy release rate of cortical bone considering anisotropic bone modelling. Proc Inst Mech Eng H 2019; 233:823-838. [PMID: 31169079 DOI: 10.1177/0954411919853918] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Stress intensity factor and energy release rate are important parameters to understand the fracture behaviour of bone. The objective of this study is to predict stress intensity factor and energy release rate using finite element method, element-free Galerkin method, and extended finite element method and compare these results with the experimentally determined values. For experimental purpose, 20 longitudinally and transversely fractured single-edge notched bend specimens were prepared and tested according to ASTM standard. All specimens were tested using the universal testing machine. For numerical simulations (finite element method, element-free Galerkin method, and extended finite element method), two-dimensional model of cortical bone was developed by assuming plane strain condition. Material properties of the cortical bone were considered as anisotropic and homogeneous. The values obtained through finite element method, element-free Galerkin method, and extended finite element method are well corroborated to experimentally determined values and earlier published data. However, element-free Galerkin method and extended finite element method predict more accurate results as compared to finite element method. In the case of the transversely fractured specimen, the values of stress intensity factor and energy release rate were found to be higher as compared to the longitudinally fractured specimen, which shows consistency with earlier published data. This study also indicates element-free Galerkin method and extended finite element method predicted stress intensity factor and energy release rate results are more close to experimental results as compared to finite element method, and therefore, these methods can be used in the different field of biomechanics, particularly to predict bone fracture.
Collapse
Affiliation(s)
- Ajay Kumar
- School of Engineering, Indian Institute of Technology Mandi, Mandi, India
| | - Pankaj Shitole
- School of Engineering, Indian Institute of Technology Mandi, Mandi, India
| | - Rajesh Ghosh
- School of Engineering, Indian Institute of Technology Mandi, Mandi, India
| | - Rajeev Kumar
- School of Engineering, Indian Institute of Technology Mandi, Mandi, India
| | - Arpan Gupta
- School of Engineering, Indian Institute of Technology Mandi, Mandi, India
| |
Collapse
|
17
|
Mondal S, Ghosh R. Effects of implant orientation and implant material on tibia bone strain, implant–bone micromotion, contact pressure, and wear depth due to total ankle replacement. Proc Inst Mech Eng H 2019; 233:318-331. [DOI: 10.1177/0954411918823811] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The aim of this study is to investigate the effects of implant orientation and implant material on tibia bone strain, implant–bone micromotion, maximum contact pressure, and wear depth at the articulating surface due to total ankle replacement. Three-dimensional finite element models of intact and implanted ankle were developed from computed tomography scan data. Four implanted models were developed having varus and valgus orientations of 5° and 10°, respectively. In order to determine the effect of implant material combination on tibia bone strain, micromotion, contact pressure, and wear depth, three other finite element models were developed having a different material combination of the implant. Dorsiflexion, neutral, and plantarflexion positions were considered as applied loading condition, along with muscle force and ligaments. Implant orientation alters the strain distribution in tibia bone. Strain shielding was found to be less in the case of the optimally positioned implant. Apart from the strain, implant orientation also affects implant–bone micromotion, contact pressure, and wear depth. Implant materials have less influence on tibia bone strain and micromotion. However, wear depth was reduced when ceramic and carbon fibre–reinforced polyetheretherketone material combination was used. Proper orientation of the implant is important to reduce the strain shielding. The present result suggested that ceramic can be used as an alternative to metal and carbon fibre–reinforced polyetheretherketone as an alternative to ultra-high molecular weight polyethylene to reduce wear, which would be beneficial for long-term success and fixation of the implant.
Collapse
Affiliation(s)
- Subrata Mondal
- School of Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh, India
| | - Rajesh Ghosh
- School of Engineering, Indian Institute of Technology Mandi, Mandi, Himachal Pradesh, India
| |
Collapse
|
18
|
Sanjay D, Mondal S, Bhutani R, Ghosh R. The effect of cement mantle thickness on strain energy density distribution and prediction of bone density changes around cemented acetabular component. Proc Inst Mech Eng H 2018; 232:912-921. [PMID: 30105942 DOI: 10.1177/0954411918793448] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Cement mantle thickness is known to be one of the important parameters to reduce the failure of the cemented acetabular component. The thickness of the cement mantle is also often influenced by the positioning of the acetabular cup. The aim of this study is to determine the effect of uniform and non-uniform cement mantle thickness on strain energy density distribution and prediction of the possibility of bone remodelling around the acetabular region. Furthermore, tensile stress distribution in the cement mantle due to non-uniform cement mantle thickness was also investigated. Three-dimensional finite element models of intact and 17 implanted pelvic bone were developed based on computed tomography data sets. Results indicate that implantation with non-uniform cement thickness variation in the anterior-posterior direction has a significant influence on strain energy density distribution around the acetabulum as compared to thickness variation in the superior-inferior direction. Increase in density is predicted at the anterior part of the acetabulum, whereas density decrease is predicted at the posterior, inferior and superior part of the acetabulum. The non-uniform cement mantle thickness affected the tensile stress distribution in the cement mantle, in particularly superiorly placed acetabular cup. This study concludes that uniform cement thickness is desired for the longer success of the cemented acetabular component.
Collapse
Affiliation(s)
- Devismita Sanjay
- 1 Biomechanics Laboratory, School of Engineering, Indian Institute of Technology Mandi, Mandi, India
| | - Subrata Mondal
- 1 Biomechanics Laboratory, School of Engineering, Indian Institute of Technology Mandi, Mandi, India
| | - Richa Bhutani
- 2 Department of Biomedical Engineering, Manipal Institute of Technology, Manipal, India
| | - Rajesh Ghosh
- 1 Biomechanics Laboratory, School of Engineering, Indian Institute of Technology Mandi, Mandi, India
| |
Collapse
|
19
|
Mondal S, Ghosh R. The Effects of Implant Orientations and Implant–Bone Interfacial Conditions on Potential Causes of Failure of Tibial Component Due to Total Ankle Replacement. J Med Biol Eng 2018. [DOI: 10.1007/s40846-018-0435-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
20
|
Nguyen VH, Rosi G, Naili S, Michel A, Raffa ML, Bosc R, Meningaud JP, Chappard C, Takano N, Haiat G. Influence of anisotropic bone properties on the biomechanical behavior of the acetabular cup implant: a multiscale finite element study. Comput Methods Biomech Biomed Engin 2017; 20:1312-1325. [PMID: 28768422 DOI: 10.1080/10255842.2017.1357703] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Although the biomechanical behavior of the acetabular cup (AC) implant is determinant for the surgical success, it remains difficult to be assessed due to the multiscale and anisotropic nature of bone tissue. The aim of the present study was to investigate the influence of the anisotropic properties of peri-implant trabecular bone tissue on the biomechanical behavior of the AC implant at the macroscopic scale. Thirteen bovine trabecular bone samples were imaged using micro-computed tomography (μCT) with a resolution of 18 μm. The anisotropic biomechanical properties of each sample were determined at the scale of the centimeter based on a dedicated method using asymptotic homogenization. The material properties obtained with this multiscale approach were used as input data in a 3D finite element model to simulate the macroscopic mechanical behavior of the AC implant under different loading conditions. The largest stress and strain magnitudes were found around the equatorial rim and in the polar area of the AC implant. All macroscopic stiffness quantities were significantly correlated (R2 > 0.85, p < 6.5 e-6) with BV/TV (bone volume/total volume). Moreover, the maximum value of the von Mises stress field was significantly correlated with BV/TV (R2 > 0.61, p < 1.6 e-3) and was always found at the bone-implant interface. However, the mean value of the microscopic stress (at the scale of the trabeculae) decrease as a function of BV/TV for vertical and torsional loading and do not depend on BV/TV for horizontal loading. These results highlight the importance of the anisotropic properties of bone tissue.
Collapse
Affiliation(s)
- Vu-Hieu Nguyen
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Giuseppe Rosi
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Salah Naili
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Adrien Michel
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Maria-Letizia Raffa
- a Laboratoire de Modélisation et de Simulation MultiEchelle, UMR CNRS 8208 , Université Paris-Est , Créteil , France
| | - Romain Bosc
- b INSERM U955 , Université Paris-Est , Créteil , France
| | | | - Christine Chappard
- c Laboratoire Bioingénierie Biomécanique Ostéo-Articulaires, UMR CNRS 7052 , Université Paris Diderot , Paris , France
| | - Naoki Takano
- d Faculty of Science and Engineering, Department of Mechanical Engineering , Keio University , Yokohama , Japan
| | - Guillaume Haiat
- e Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208 , Créteil , France.,f École de technologie supérieure , Montreal , Canada.,g Research Center, Hôpital du Sacré-Cœur de Montréal , Montreal , Canada
| |
Collapse
|
21
|
Mukherjee K, Gupta S. Combined Bone Ingrowth and Remodeling Around Uncemented Acetabular Component: A Multiscale Mechanobiology-Based Finite Element Analysis. J Biomech Eng 2017; 139:2644120. [PMID: 28696483 DOI: 10.1115/1.4037223] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Indexed: 11/08/2022]
Abstract
Bone ingrowth and remodeling are two different evolutionary processes which might occur simultaneously. Both these processes are influenced by local mechanical stimulus. However, a combined study on bone ingrowth and remodeling has rarely been performed. This study is aimed at understanding the relationship between bone ingrowth and adaptation and their combined influence on fixation of the acetabular component. Based on three-dimensional (3D) macroscale finite element (FE) model of implanted pelvis and microscale FE model of implant–bone interface, a multiscale framework has been developed. The numerical prediction of peri-acetabular bone adaptation was based on a strain-energy density-based formulation. Bone ingrowth in the microscale models was simulated using the mechanoregulatory algorithm. An increase in bone strains near the acetabular rim was observed in the implanted pelvis model, whereas the central part of the acetabulum was observed to be stress shielded. Consequently, progressive bone apposition near the acetabular rim and resorption near the central region were observed. Bone remodeling caused a gradual increase in the implant–bone relative displacements. Evolutionary bone ingrowth was observed around the entire acetabular component. Poor bone ingrowth of 3–5% was predicted around the centro-inferio and inferio-posterio-superio-peripheral regions owing to higher implant–bone relative displacements, whereas the anterio-inferior and centro-superior regions exhibited improved bone ingrowth of 35–55% due to moderate implant–bone relative displacement. For an uncemented acetabular CoCrMo component, bone ingrowth had hardly any effect on bone remodeling; however, bone remodeling had considerable influence on bone ingrowth.
Collapse
Affiliation(s)
- Kaushik Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Sanjay Gupta
- Professor Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India e-mail:
| |
Collapse
|
22
|
Mukherjee K, Gupta S. Influence of Implant Surface Texture Design on Peri-Acetabular Bone Ingrowth: A Mechanobiology Based Finite Element Analysis. J Biomech Eng 2017; 139:2592752. [PMID: 27925634 DOI: 10.1115/1.4035369] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Indexed: 11/08/2022]
Abstract
The fixation of uncemented acetabular components largely depends on the amount of bone ingrowth, which is influenced by the design of the implant surface texture. The objective of this numerical study is to evaluate the effect of these implant texture design factors on bone ingrowth around an acetabular component. The novelty of this study lies in comparative finite element (FE) analysis of 3D microscale models of the implant-bone interface, considering patient-specific mechanical environment, host bone material property and implant-bone relative displacement, in combination with sequential mechanoregulatory algorithm and design of experiment (DOE) based statistical framework. Results indicated that the bone ingrowth process was inhibited due to an increase in interbead spacing from 200 μm to 600 μm and bead diameter from 1000 μm to 1500 μm and a reduction in bead height from 900 μm to 600 μm. Bead height, a main effect, was found to have a predominant influence on bone ingrowth. Among the interaction effects, the combination of bead height and bead diameter was found to have a pronounced influence on bone ingrowth process. A combination of low interbead spacing (P = 200 μm), low bead diameter (D = 1000 μm), and high bead height (H = 900 μm) facilitated peri-acetabular bone ingrowth and an increase in average Young's modulus of newly formed tissue layer. Hence, such a surface texture design seemed to provide improved fixation of the acetabular component.
Collapse
Affiliation(s)
- Kaushik Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India
| | - Sanjay Gupta
- Professor Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India e-mail:
| |
Collapse
|
23
|
Liu D, Hua Z, Yan X, Jin Z. Biomechanical analysis of a novel hemipelvic endoprosthesis during ascending and descending stairs. Proc Inst Mech Eng H 2016; 230:962-75. [PMID: 27587536 DOI: 10.1177/0954411916663970] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Accepted: 07/21/2016] [Indexed: 11/16/2022]
Abstract
In this study, the biomechanical characteristic of a newly developed adjustable hemipelvic prosthesis under dynamic loading conditions was investigated using explicit finite element method. Both intact and reconstructed pelvis models, including pelvis, femur and soft tissues, were established referring to human anatomic data using a solid geometry of a human pelvic bone. Hip contact forces during ascending stairs and descending stairs were imposed on pelvic models. Results showed that maximum von Mises stresses in reconstructed pelvis were 421.85 MPa for prostheses and 109.12 MPa for cortical bone, which were still within a low and elastic range below the yielding strength of Ti-6Al-4V and cortical bone, respectively. Besides, no significant difference of load transferring paths along pelvic rings was observed between the reconstructed pelvis and natural pelvis models. And good agreement was found between the overall distribution of maximum principal stresses in trabecular bones of reconstructed pelvis and natural pelvis, while at limited stances, principal stresses in trabecular bone of reconstructed pelvis were slightly lower than natural pelvis. The results indicated that the load transferring function of pelvis could be restored by this adjustable hemipelvic prosthesis. Moreover, the prosthesis was predicted to have a reliable short- and long-term performance. However, due to the occurrence of slightly lower principal stresses at a few stances, a porous structure applied on the interface between the prosthesis and bone would be studied in future work to obtain better long-term stability.
Collapse
Affiliation(s)
- Dongxu Liu
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, P.R. China
| | - Zikai Hua
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, P.R. China
| | - Xinyi Yan
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, P.R. China
| | - Zhongmin Jin
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, P.R. China School of Mechanical Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
24
|
Mukherjee K, Gupta S. The effects of musculoskeletal loading regimes on numerical evaluations of acetabular component. Proc Inst Mech Eng H 2016; 230:918-29. [DOI: 10.1177/0954411916661368] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Accepted: 07/05/2016] [Indexed: 11/17/2022]
Abstract
The importance of clinical studies notwithstanding, the failure assessment of implant–bone structure has alternatively been carried out using finite element analysis. However, the accuracy of the finite element predicted results is dependent on the applied loading and boundary conditions. Nevertheless, most finite element–based evaluations on acetabular component used a few selective load cases instead of the eight load cases representing the entire gait cycle. These in silico evaluations often suffer from limitations regarding the use of simplified musculoskeletal loading regimes. This study attempts to analyse the influence of three different loading regimes representing a gait cycle, on numerical evaluations of acetabular component. Patient-specific computer tomography scan-based models of intact and resurfaced pelvises were used. One such loading regime consisted of the second load case that corresponded to peak hip joint reaction force. Whereas the other loading regime consisted of the second and fifth load cases, which corresponded to peak hip joint reaction force and peak muscle forces, respectively. The third loading regime included all the eight load cases. Considerable deviations in peri-acetabular strains, standard error ranging between 115 and 400 µε, were observed for different loading regimes. The predicted bone strains were lower when selective loading regimes were used. Despite minor quantitative variations in bone density changes (less than 0.15 g cm−3), the final bone density pattern after bone remodelling was found to be similar for all the loading regimes. Underestimations in implant–bone micromotions (40–50 µm) were observed for selective loading regimes after bone remodelling. However, at immediate post-operative condition, such underestimations were found to be less (less than 5 µm). The predicted results highlight the importance of inclusion of eight load cases representing the gait cycle for in silico evaluations of resurfaced pelvis.
Collapse
Affiliation(s)
- Kaushik Mukherjee
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| |
Collapse
|
25
|
Ghosh R. Assessment of failure of cemented polyethylene acetabular component due to bone remodeling: A finite element study. J Orthop 2016; 13:140-7. [PMID: 27408485 DOI: 10.1016/j.jor.2016.03.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 03/06/2016] [Indexed: 11/18/2022] Open
Abstract
The aim of the study is to determine failure of the cemented polyethylene acetabular component, which might occur due to excessive bone resorption, cement-bone interface debonding and fatigue failure of the cement mantle. Three-dimensional finite element models of intact and implanted pelvic bone were developed and bone remodeling algorithm was implemented for present analysis. Soderberg fatigue failure diagram was used for fatigue assessment of the cement mantle. Hoffman failure criterion was considered for prediction of cement-bone interface debonding. Results indicate fatigue failure of the cement mantle and implant-bone interface debonding might not occur due to bone remodeling.
Collapse
Affiliation(s)
- Rajesh Ghosh
- School of Engineering, Indian Institute of Technology Mandi, Mandi 175001, Himachal Pradesh, India
| |
Collapse
|
26
|
Mechanobiological simulations of peri-acetabular bone ingrowth: a comparative analysis of cell-phenotype specific and phenomenological algorithms. Med Biol Eng Comput 2016; 55:449-465. [DOI: 10.1007/s11517-016-1528-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Accepted: 05/13/2016] [Indexed: 10/21/2022]
|
27
|
Activity intensity, assistive devices and joint replacement influence predicted remodelling in the proximal femur. Biomech Model Mechanobiol 2015; 15:181-94. [DOI: 10.1007/s10237-015-0678-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2014] [Accepted: 04/17/2015] [Indexed: 10/23/2022]
|
28
|
Bone ingrowth around porous-coated acetabular implant: a three-dimensional finite element study using mechanoregulatory algorithm. Biomech Model Mechanobiol 2015; 15:389-403. [PMID: 26130375 DOI: 10.1007/s10237-015-0696-7] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2014] [Accepted: 06/15/2015] [Indexed: 10/23/2022]
Abstract
Fixation of uncemented implant is influenced by peri-prosthetic bone ingrowth, which is dependent on the mechanical environment of the implant-bone structure. The objective of the study is to gain an insight into the tissue differentiation around an acetabular component. A mapping framework has been developed to simulate appropriate mechanical environment in the three-dimensional microscale model, implement the mechanoregulatory tissue differentiation algorithm and subsequently assess spatial distribution of bone ingrowth around an acetabular component, quantitatively. The FE model of implanted pelvis subjected to eight static load cases during a normal walking cycle was first solved. Thereafter, a mapping algorithm has been employed to include the variations in implant-bone relative displacement and host bone material properties from the macroscale FE model of implanted pelvis to the microscale FE model of the beaded implant-bone interface. The evolutionary tissue differentiation was observed in each of the 13 microscale models corresponding to 13 acetabular regions. The total implant-bone relative displacements, averaged over each region of the acetabulum, were found to vary between 10 and 60 μm. Both the linear elastic and biphasic poroelastic models predicted similar mechanoregulatory peri-prosthetic tissue differentiation. Considerable variations in bone ingrowth (13-88%), interdigitation depth (0.2-0.82 mm) and average tissue Young's modulus (970-3430 MPa) were predicted around the acetabular cup. A progressive increase in the average Young's modulus, interdigitation depth and decrease in average radial strains of newly formed tissue layer were also observed. This scheme can be extended to investigate tissue differentiation for different surface texture designs on the implants.
Collapse
|
29
|
Chanda S, Gupta S, Kumar Pratihar D. A Genetic Algorithm Based Multi-Objective Shape Optimization Scheme for Cementless Femoral Implant. J Biomech Eng 2015; 137:1936138. [PMID: 25392855 DOI: 10.1115/1.4029061] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2014] [Indexed: 11/08/2022]
Abstract
The shape and geometry of femoral implant influence implant-induced periprosthetic bone resorption and implant-bone interface stresses, which are potential causes of aseptic loosening in cementless total hip arthroplasty (THA). Development of a shape optimization scheme is necessary to achieve a trade-off between these two conflicting objectives. The objective of this study was to develop a novel multi-objective custom-based shape optimization scheme for cementless femoral implant by integrating finite element (FE) analysis and a multi-objective genetic algorithm (GA). The FE model of a proximal femur was based on a subject-specific CT-scan dataset. Eighteen parameters describing the nature of four key sections of the implant were identified as design variables. Two objective functions, one based on implant-bone interface failure criterion, and the other based on resorbed proximal bone mass fraction (BMF), were formulated. The results predicted by the two objective functions were found to be contradictory; a reduction in the proximal bone resorption was accompanied by a greater chance of interface failure. The resorbed proximal BMF was found to be between 23% and 27% for the trade-off geometries as compared to ∼39% for a generic implant. Moreover, the overall chances of interface failure have been minimized for the optimal designs, compared to the generic implant. The adaptive bone remodeling was also found to be minimal for the optimally designed implants and, further with remodeling, the chances of interface debonding increased only marginally.
Collapse
Affiliation(s)
- Souptick Chanda
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India e-mail:
| | - Dilip Kumar Pratihar
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721 302, India
| |
Collapse
|
30
|
Bone loss around a stable, partly threaded hydroxyapatite-coated cup: a prospective cohort study using RSA and DXA. Hip Int 2014; 24:155-66. [PMID: 24500826 DOI: 10.5301/hipint.5000104] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/21/2013] [Indexed: 02/04/2023]
Abstract
STUDY PURPOSE Aseptic loosening of the acetabular component is the most common reason for revision after primary THA, and periprosthetic demineralisation has been described as a potential cause for this process. The trabeculae-oriented pattern (TOP)-cup is a flat, hydroxyapatite (HA)-coated titanium shell with a threaded rim that was developed in order to minimise periprosthetic bone loss. We hypothesised that this cup provides good primary stability and improves preservation of periprosthetic bone mineral density (BMD). BASIC PROCEDURES A prospective cohort study on 30 patients receiving the TOP cup was carried out. Preoperative total hip BMD and postoperative periprosthetic BMD in five periprosthetic regions of interest were investigated by dual energy radiographic absorptiometry (DXA), cup migration was analysed by radiostereometry (RSA), and the Harris hips score (HHS) was determined. MAIN FINDINGS Mean HHS increased from 49 (24-79) preoperatively to 99 (92-100) after two years. DXA after one year demonstrated substantial BMD loss in the proximal periprosthetic zones 1 (-18%), zone 2 (-16 %) and zone 3 (-9%, all p<0.001 when compared with baseline BMD determined immediately postoperatively). The bone loss in these regions did not recover after two years. RSA (performed on 16 patients) showed that only very limited micromotion of the implant occurred: Mean cranial migration was 0.01 mm (95% confidence interval (CI): -0.09-0.12) and mean inclination decreased by 0.02º (CI: -0.43-0.39) after two years. CONCLUSION We conclude that the TOP cup provides good primary stability in the short-term. However, substantial BMD loss in proximal periprosthetic areas indicates that the design of this cup cannot prevent periprosthetic bone loss that has also been observed around other uncemented cups.
Collapse
|
31
|
Ghosh R, Gupta S. Bone remodelling around cementless composite acetabular components: the effects of implant geometry and implant-bone interfacial conditions. J Mech Behav Biomed Mater 2014; 32:257-269. [PMID: 24508712 DOI: 10.1016/j.jmbbm.2014.01.010] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Revised: 01/10/2014] [Accepted: 01/13/2014] [Indexed: 11/27/2022]
Abstract
Recent developments in acetabular implants suggest flexible, alternative bearing material that may reduce wear and peri-prosthetic bone resorption. The goal of this study was to investigate the deviations in load transfer and the extent of bone remodelling around composite acetabular components having different geometries, material properties and implant-bone interface conditions, using 3-D FE analysis and bone remodelling algorithm. Variation in prosthesis type and implant-bone interface conditions affected peri-prosthetic strain distribution and bone remodelling. Strain shielding was considerably higher for bonded implant-bone interface condition as compared to debonded implant-bone interface condition. The average bone deformation (0.133mm) for horseshoe-shaped CFR-PEEK (resembling MITCH PCR(TM) cup) was very close to that of the intact acetabulum (0.135mm) at comparable locations. A reduction in bone density of 21-50% was predicted within the acetabulum for the implant resembling Cambridge cup, having bonded interface. For debonded interface condition, bone density increase of ~55% was observed in the supero-posterior part of acetabulum, whereas bone density reductions were low (1-20%) in other locations. Bone density reductions were considerably less (2-4%) for horseshoe-shaped CFR-PEEK component. Moreover, an increase in bone density of 1-87% was predicted around the acetabulum. Compared to the horseshoe-shaped design, the hemispherical design exacerbated bone resorption. Results indicated that the thickness of the acetabular component played a crucial role in the implant induced bone adaptation. The horseshoe-shaped CFR-PEEK component of 3mm thickness seemed a better alternative bearing surface than other designs, with regard to strain shielding, bone deformation and bone remodelling.
Collapse
Affiliation(s)
- Rajesh Ghosh
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India.
| |
Collapse
|