1
|
Cardona-Arias JA, Higuita Gutiérrez LF, Carmona-Fonseca J. Diagnostic Accuracy of a Thick Blood Smear Compared to qPCR for Malaria Associated with Pregnancy in Colombia. Trop Med Infect Dis 2023; 8:tropicalmed8020119. [PMID: 36828535 PMCID: PMC9959527 DOI: 10.3390/tropicalmed8020119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/17/2023] [Accepted: 01/20/2023] [Indexed: 02/17/2023] Open
Abstract
This study aimed to evaluate the accuracy of the thick blood smear (TBS) versus quantitative polymerase chain reaction (qPCR) for the diagnosis of malaria associated with pregnancy (MAP) caused by P. falciparum or P. vivax in Colombia in its gestational malaria (GM), placental malaria (PM), and congenital malaria (CM) forms as well as to compare its accuracy in different subgroups of pregnant women according to the presence of fever, anemia and a history of malaria. This was a diagnostic evaluation of 829 pregnant women, 579 placentas, 381 umbilical cord samples, and 221 neonatal peripheral blood samples. Accuracy was evaluated based on the parameters of sensitivity, specificity, predictive values, likelihood ratios, and validity index, with their 95% confidence intervals. The frequency of GM was 36% (n = 297/829), PM 27% (n = 159/579), and CM 16.5% (n = 63/381) in umbilical cord samples and 2% (n = 5/221) in neonatal peripheral blood samples. For GM, the sensitivity was 55%, with higher rates in those infected with P. vivax (68%), with a history of malaria (69%), and with fever (96%). These three subgroups presented the best results in terms of the negative likelihood ratio and validity index. For PM, sensitivity was 8%; in subgroup analyses in terms of species, symptomatology (anemia and fever), and history of malaria, it was 1-18%, and the negative likelihood ratio was >0.80 in all subgroups. No false positives were recorded in any of the subgroups. The TBS did not detect any cases of CM. This study found the TBS yielded satisfactory results in terms of diagnosing GM for P. vivax, pregnant women with previous malaria and febrile. It also showed that the TBS is not useful for diagnosing PM and CM. It is necessary to conduct surveillance of MAP with molecular methods in in groups where TBS is deficient (asymptomatic GM, P. falciparum, and pregnant women without history of malaria) to optimize the timely treatment of PM and CM, avoid the deleterious effects of MAP and achieve the malaria elimination goals in Colombia.
Collapse
Affiliation(s)
| | - Luis Felipe Higuita Gutiérrez
- Escuela de Microbiología, Universidad de Antioquia, Medellín 050010, Colombia
- Facultad de Medicina, Universidad Cooperativa de Colombia, Medellín 050010, Colombia
| | - Jaime Carmona-Fonseca
- Grupo Salud y Comunidad César Uribe Piedrahíta, Facultad de Medicina, Universidad de Antioquia, Medellín 050010, Colombia
| |
Collapse
|
2
|
Gómez-Hoyos R, Cardona-Arias JA, Higuita Gutiérrez LF, Salas-Zapata W, Carmona-Fonseca J. Systematic review of the diagnostic accuracy of thick smear compared to polymerase chain reaction for pregnancy-associated malaria, 2010-2022. Rev Peru Med Exp Salud Publica 2022; 39:302-311. [PMID: 36478163 PMCID: PMC11397769 DOI: 10.17843/rpmesp.2022.393.11739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 09/28/2022] [Indexed: 11/09/2022] Open
Abstract
OBJECTIVE. To evaluate the accuracy of thick smear (TS) versus quantitative polymerase chain reaction (PCR) for pregnancy-associated malaria (PAM). MATERIALS AND METHODS. We carried out a systematic review of diagnostic tests in nine databases. Methodological quality was evaluated with QUADAS. Sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR) and area under the ROC curve were estimated. Heterogeneity was determined with the Der Simonian-Laird Q method and uncertainty with the weighted percentage of each study on the overall result. RESULTS. We included 10 studies with 5691 pregnant women, 1415 placentas and 84 neonates. In the studies with nested PCR (nPCR) and quantitative PCR (qPCR) as the standard, the diagnostic accuracy results were statistically similar, with very low sensitivity (50 and 54%, respectively), high specificity (99% in both cases), high PLR and poor NLR. When nPCR was used, the DOR was 162 (95%CI=66-401) and the area under the ROC curve was 95%, while with qPCR it was 231 (95%CI=27-1951) and 78%, respectively. CONCLUSIONS. We demonstrated that research on the diagnostic accuracy of TS in PAM is limited. Microscopy showed poor performance in the diagnosis of asymptomatic or low parasitemia infections, which reinforces the importance of implementing other types of techniques for the follow-up and control of malaria infections in pregnant women, in order to achieve the control and possible elimination of PAM.
Collapse
Affiliation(s)
| | | | | | | | - Jaime Carmona-Fonseca
- Grupo Salud y Comunidad César Uribe Piedrahíta, Facultad de Medicina, Universidad de Antioquia, Medellín, Colombia
| |
Collapse
|
3
|
Ebong CE, Ali IM, Fouedjio HJ, Essangui E, Achu DF, Lawrence A, Sama D. Diagnosis of malaria in pregnancy: accuracy of CareStart™ malaria Pf/PAN against light microscopy among symptomatic pregnant women at the Central Hospital in Yaoundé, Cameroon. Malar J 2022; 21:78. [PMID: 35264170 PMCID: PMC8905860 DOI: 10.1186/s12936-022-04109-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 02/27/2022] [Indexed: 11/23/2022] Open
Abstract
Background The need to start treatment early for pregnant women who present with clinical features of malaria usually conflicts with the need to confirm diagnosis by microscopy (MP) before treatment, due to delays in obtaining results. Parasite sequestration in the placenta is also a problem. Rapid diagnostic tests (RDT), which detect soluble antigens, are a valuable alternative. The objective of this study was to evaluate pretreatment parasite prevalence by microscopy and by RDT and to assess the accuracy of RDT with MP as reference. Methods A prospective cross-sectional study was carried out at the obstetrical unit of the Central Hospital in Yaoundé, during the period January-August 2015. Consenting patients with symptoms of suspected malaria in pregnancy were recruited and a blood sample taken for MP and RDT before treatment was started. The estimates of diagnostic performance (with 95% confidence interval) were calculated in OpenEpi online software using the Wilson’s score. The agreement, as reflected by the Cohen’s kappa, was calculated and interpreted using known intervals. Results The results showed that, out of the 104 patients recruited, 69.2% (95%CI: 59.1–77.5) were MP positive while 77.94% (95%CI: 63.1–80.9) were RDT positive. The sensitivity of the malaria RDT was 91.67% (95%CI: 83.69–96.77) while the specificity was 53.13% (95%CI: 31.39–65.57). The diagnostic accuracy of the RDT with MP as reference was 79.81% (95%CI: 70.0–86.1). All cases were due to Plasmodium falciparum. A Cohen’s kappa of 0.45 (95%CI: 0.26–0.64) was obtained, consistent with a moderate agreement between the tests. Conclusions The diagnostic accuracy of the CareStart™ malaria Pf/PAN compared to microscopy was high, but not as desirable, with a false negative RDT at very high parasitaemia. In tertiary facilities, RDTs appear to provide a better diagnostic solution compared to microscopy. However, future studies with larger sample sizes should make this observation more generalizable; as missing a case could have serious consequences on pregnancy outcome. Supplementary Information The online version contains supplementary material available at 10.1186/s12936-022-04109-6.
Collapse
Affiliation(s)
- Cliford Ebontane Ebong
- Department of Gynecology/Obstetrics, Faculty of Medicine and Biomedical Sciences, University of Yaoundé 1, Yaoundé, Cameroon. .,Gynecology and Obstetrics Unit, Central Hospital of Yaoundé, Yaoundé, Cameroon.
| | - Innocent Mbulli Ali
- Department of Biochemistry, Faculty of Science, University of Dschang, Dschang, Cameroon
| | - Hortence Jeanne Fouedjio
- Department of Gynecology/Obstetrics, Faculty of Medicine and Biomedical Sciences, University of Yaoundé 1, Yaoundé, Cameroon.,Gynecology and Obstetrics Unit, Central Hospital of Yaoundé, Yaoundé, Cameroon
| | | | - Dorothy Fosah Achu
- Ministry of Public Health, National Malaria Control Programme, Yaoundé, Cameroon
| | - Ayong Lawrence
- Malaria Unit, Centre Pasteur du Cameroun, Yaoundé, Cameroon
| | - Dohbit Sama
- Department of Gynecology/Obstetrics, Faculty of Medicine and Biomedical Sciences, University of Yaoundé 1, Yaoundé, Cameroon. .,Gyneco-Obstetric and Paediatric Hospital of Yaoundé, Yaoundé, Cameroon.
| |
Collapse
|
4
|
Performance Evaluation of Malaria Pf/Pv Combo Test Kit at Highly Malaria-Endemic Area, Southern Ethiopia: A Cross-Sectional Study. J Trop Med 2020; 2020:1807608. [PMID: 32963553 PMCID: PMC7492921 DOI: 10.1155/2020/1807608] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 08/05/2020] [Accepted: 08/26/2020] [Indexed: 11/18/2022] Open
Abstract
Background Malaria rapid diagnostic tests (RDTs) are alternative diagnostic methods that have enabled reliable biological diagnostic testing in all situations where previously only clinical diagnosis was available. Varying diagnostic accuracy of malaria RDTs makes policymakers confused while choosing malaria test kits for their country. Objective The aim of this study was to evaluate the diagnostic performance of currently being used malaria RDT in Southern Ethiopia. Methods A cross-sectional study design was conducted from October 1 to December 15, 2016. A total of 160 patients were included in the study. Finger-prick blood sample was obtained from study subjects for the RDT test and microscopic examination. Collected data were entered and analyzed using SPSS version 20.0. Result The test kit evaluated had an overall sensitivity, specificity, PPV, and NPV of 97.44%, 93.67%, 93.83%, and 97.37%, respectively, to detect the presence or absence of malaria. Sensitivity and specificity of the kit for P. falciparum detection were 63.27% and 94.3% and for P. vivax detection were 86.96% and 95.62%, respectively. The agreement between microscopy and RDT for specific identification of malaria species was moderate with a kappa value of 0.568. Conclusion The overall performance of the kit was below the WHO standard. Further study on a large sample size is recommended to be carried out in the study area to use the test kit instead of microscopy for malaria diagnosis. Providing training on quality malaria laboratory diagnosis and availing necessary supplies for malaria diagnosis shall also be considered.
Collapse
|
5
|
Megnekou R, Djontu JC, Nana BC, Bigoga JD, Fotso M, Fogang B, Leke RFG. Accuracy of One Step malaria rapid diagnostic test (RDT) in detecting Plasmodium falciparum placental malaria infection in women living in Yaoundé, Cameroon. Malar J 2018; 17:450. [PMID: 30514316 PMCID: PMC6278062 DOI: 10.1186/s12936-018-2595-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Accepted: 11/23/2018] [Indexed: 11/23/2022] Open
Abstract
Background Plasmodium falciparum infected erythrocytes sequestering in placental tissue release Plasmodium lactate dehydrogenase (pLDH) and histidine-rich protein-II (HRP-II). These proteins can be detected in peripheral blood using monoclonal antibody-based rapid diagnostic tests (RDTs). Nevertheless, studies to evaluate the reliability of RDTs in detecting placental malaria compared with microscopy of placental tissue impression smear (PTIS) as the gold standard are scarce. Methods Between August 2013 and January 2015, Giemsa-stained blood smears for peripheral blood smear (Pbs), placental intervillous space (IVS) blood smear and placental tissue impression smear (PTIS)] were prepared from HIV-negative women during delivery at the Marie Reine Medical Health Centre in Yaoundé, Cameroon. RDTs with monoclonal antibodies specific to HRP-II (P.f) or pLDH (Pan) antigens were used to screen maternal peripheral blood samples. Results The prevalence of malaria was 16%, 7.5%, 11.5%, 8% and 13% for One Step malaria HRP-II and pLDH RDTs, peripheral blood smear, IVS blood and placental tissue impression smears, respectively. The proportion of women positive by One Step malaria pLDH RDT and Pbs increased with parasite density in PTIS, while One Step malaria HRP-II RDT detected high proportion of infected women even with low parasite density. Although the prevalence of malaria infection by both microscopy and RDTs decreased significantly with mother age (0.0008 ≤ p ≤ 0.025), parity seemed to have very little influence. The sensitivity of One Step malaria HRP-II and pLDH RDTs were 96.15% and 61.53%, respectively, compared to 80.76% for Pbs (p = 0.014 and 0.0029, respectively). The specificity of these RDTs was 96.49% and 100%, respectively, compared to 100% for Pbs (p ≥ 0.12). In addition, the positive predictive values were 80.64% and 100% for HRP-II and pLDH-based RDTs, respectively, compared to 100% for Pbs (p < 0.0001 and 1, respectively), while the negative predictive values were 99.40% and 94.48%, respectively, compared to 97.16% for Pbs (p ≥ 0.49). The combination of One Step malaria HRP-II RDT and Pbs showed the similar performance as that observed with One Step malaria HRP-II RDT only. Conclusion These results depict One Step malaria HRP-II RDT to be better in detecting placental P. falciparum infection in pregnant women compared to Giemsa-stained peripheral thick blood smear. This is important for better case management since microscopic examination of PTIS cannot be employed during pregnancy.
Collapse
Affiliation(s)
- Rosette Megnekou
- Department of Animals Biology and Physiology, Faculty of Sciences, University of Yaoundé I, PO. BOX: 812, Yaoundé, Cameroon. .,The Biotechnology Center, University of Yaoundé I, P.O. Box 3851, Messa, Yaoundé, Cameroon.
| | - Jean Claude Djontu
- Department of Animals Biology and Physiology, Faculty of Sciences, University of Yaoundé I, PO. BOX: 812, Yaoundé, Cameroon.,The Biotechnology Center, University of Yaoundé I, P.O. Box 3851, Messa, Yaoundé, Cameroon
| | - Benderli C Nana
- Department of Animals Biology and Physiology, Faculty of Sciences, University of Yaoundé I, PO. BOX: 812, Yaoundé, Cameroon.,The Biotechnology Center, University of Yaoundé I, P.O. Box 3851, Messa, Yaoundé, Cameroon
| | - Jude D Bigoga
- The Biotechnology Center, University of Yaoundé I, P.O. Box 3851, Messa, Yaoundé, Cameroon.,Department of Biochemistry, Faculty of Sciences, University of Yaoundé I, P.O. Box 812, Yaoundé, Cameroon
| | - Maurice Fotso
- School of Health Science, Catholic University of Central Africa, P.O. Box 1110, Yaoundé, Cameroon
| | - Balotin Fogang
- Department of Animals Biology and Physiology, Faculty of Sciences, University of Yaoundé I, PO. BOX: 812, Yaoundé, Cameroon.,The Biotechnology Center, University of Yaoundé I, P.O. Box 3851, Messa, Yaoundé, Cameroon
| | - Rose F G Leke
- The Biotechnology Center, University of Yaoundé I, P.O. Box 3851, Messa, Yaoundé, Cameroon
| |
Collapse
|
6
|
Performance of a highly sensitive rapid diagnostic test (HS-RDT) for detecting malaria in peripheral and placental blood samples from pregnant women in Colombia. PLoS One 2018; 13:e0201769. [PMID: 30071004 PMCID: PMC6072118 DOI: 10.1371/journal.pone.0201769] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Accepted: 07/20/2018] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Pregnancy poses specific challenges for the diagnosis of Plasmodium falciparum infection due to parasite sequestration in the placenta, which translates in low circulation levels in peripheral blood. The aim of this study is to assess the performance of a new highly sensitive rapid diagnostic test (HS-RDT) for the detection of malaria in peripheral and placental blood samples from pregnant women in Colombia. METHODS This is a retrospective study using 737 peripheral and placental specimens collected from pregnant women in Colombian malaria-endemic regions. Light microscopy (LM), conventional rapid diagnostic tests (Pf/Pv RDT and Pf RDT), and HS-RDT testing were performed. Diagnostic accuracy endpoints of LM, HS-RDT and RDTs were compared with nested polymerase chain reaction (nPCR) as the reference test. RESULTS In comparison with nPCR, the sensitivity of HS-RDT, Pf RDT, Pf/Pv RDT and LM to detect infection in peripheral samples was 85.7% (95% CI = 70.6-93.7), 82.8% (95% CI = 67.3-91.9), 77.1% (95% CI = 61.0-87.9) and 77.1% (95% CI = 61.0-87.9) respectively. The sensitivity to detect malaria in asymptomatic women, was higher with HS-RDT, where LM and Pf/Pv RDT missed half of infections detected by nPCR, but differences were not significant. Overall, specificity was similar for all tests (>99.0%). In placental blood, the prevalence of infection by P. falciparum by nPCR was 2.8% (8/286), by HS-RDT was 1% and by conventional RDTs (Pf RDT and Pf/Pv RDT) and LM was 0.7%. The HS-RDT detected placental infections in peripheral blood that were negative by LM and Pf/Pv RDT, however the number of positive placentas was low. CONCLUSIONS The sensitivity of HS-RDT to detect P. falciparum infections in peripheral and placental samples from pregnant women was slightly better compared to routinely used tests during ANC visits and at delivery. Although further studies are needed to guide recommendations on the use of the HS-RDT for malaria case management in pregnancy, this study shows the potential value of this test to diagnose malaria in pregnancy in low-transmission settings.
Collapse
|
7
|
Fadlelseed OE, Osman ME, Shamseldin NM, Elhussein AB, Adam I. Plasmodium falciparum genotypes in matched peripheral, placental and umbilical cord blood in an area characterised by unstable malaria transmission in eastern Sudan. Heliyon 2017; 3:e00326. [PMID: 28653041 PMCID: PMC5476470 DOI: 10.1016/j.heliyon.2017.e00326] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2016] [Revised: 04/18/2017] [Accepted: 06/08/2017] [Indexed: 12/01/2022] Open
Abstract
Background There are few published studies on Plasmodium falciparum genotypes in peripheral, placental and umbilical cord blood in areas characterised by unstable malaria transmission. Method A cross-sectional study was conducted to investigate P. falciparum genotypes in matched peripheral, placental and umbilical cord blood in eastern Sudan. Thick blood smears and P. falciparum merozoite surface protein 1 (MSP1) and 2 (MSP2) genes as polymorphic markers in polymerase chain reactions were investigated in 3 kinds of samples of 153 pregnant women at delivery. Results There was no significant difference in the prevalence of blood film-detected P. falciparum in which 5 (3.3%), 7 (4.6%) and 3 (2.0%) (P = 0.437) of the 153 samples were determined to be P. falciparum-positive by microscopy for maternal peripheral, placental and cord blood samples, respectively. Out of these 145 samples, 24 (16.6%), 39 (26.9%) and 24 (16.6%) (P = 0.039) of the peripheral, placental and cord samples, respectively, had submicroscopic parasitaemia (blood films were negative). There was no association between submicroscopic parasitaemia and age or parity. RO33 and K1 (MSP1 alleles) were detected in 21/29 (72.4%), 42/46 (85.7%), 26/27 (92.2%) and 6/29 (20.6), 16/46 (32.6) and 0(0) (P < 0.001) of the maternal, placental and cord samples, respectively. MAD20 was not detected in any of the samples. While the 3D7/IC1 allele was detected in 12 (41.3%), 30 (65.2%) and 4 (14.8%) (P < 0.001) of the peripheral, placental and cord samples, respectively, the FC (MSP2) allele was detected in only the 6 (20.6) placental samples. Multi-clonal infection was detected in 10 (34.4), 27 (58.6) and 3 (11.1) (P < 0.001) of the maternal placental and cord samples, respectively. Conclusion Compared with the peripheral and cord samples, placental samples had a higher prevalence of submicroscopic parasitaemia. MSP1 alleles were predominant in the cord, while MSP2 alleles were predominant in the placental samples, which had a significant higher multiplicity of the infection.
Collapse
Affiliation(s)
| | - Maha E Osman
- Commission for Biotechnology and Genetic Engineering National Centre for Research, Khartoum, Sudan
| | - Nahla M Shamseldin
- Commission for Biotechnology and Genetic Engineering National Centre for Research, Khartoum, Sudan
| | | | - Ishag Adam
- Faculty of Medicine, University of Khartoum, P. O. Box 102, Khartoum 11111, Sudan
| |
Collapse
|
8
|
Ugah UI, Alo MN, Owolabi JO, Okata-Nwali OD, Ekejindu IM, Ibeh N, Elom MO. Evaluation of the utility value of three diagnostic methods in the detection of malaria parasites in endemic area. Malar J 2017; 16:189. [PMID: 28477621 PMCID: PMC5420404 DOI: 10.1186/s12936-017-1838-4] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2017] [Accepted: 04/26/2017] [Indexed: 11/16/2022] Open
Abstract
Background Malaria is a debilitating disease with high morbidity and mortality in Africa, commonly caused by different species of the genus Plasmodium in humans. Misdiagnosis is a major challenge in endemic areas because of other disease complications and technical expertise of the medical laboratory staff. Microscopic method using Giemsa-stained blood film has been the mainstay of diagnosis of malaria. However, since 1993 when rapid diagnostic test (RDT) kits were introduced, they have proved to be effective in the diagnosis of malaria. This study was aimed at comparing the accuracy of microscopy and RDTs in the diagnosis of malaria using nested PCR as the reference standard. Four hundred and twenty (420) venous blood specimens were collected from patients attending different General Hospitals in Ebonyi State with clinical symptoms of malaria. The samples were tested with Giemsa-stained microscopy and three RDTs. Fifty specimens were randomly selected for molecular analysis. Results Using different diagnostic methods, the prevalence of malaria among the subjects studied was 25.95% as detected by microscopy, prevalence found among the RDTs was 22.90, 15.20 and 54.80% for Carestart, SD Bioline PF and SD Bioline PF/PV, respectively. Molecular assay yielded a prevalence of 32%. The major specie identified was Plasmodium falciparum; there was co-infection of P. falciparum with Plasmodium malariae and Plasmodium ovale. The sensitivity and specificity of microscopy was 50.00 and 70.59% while that of the RDTs were (25.00 and 85.29%), (25.00 and 94.12%) and (68.75 and 52.94%) for Carestart, SD Bioline PF and SD Bioline PF/PV, respectively. Cohen’s kappa coefficient was used to measure the level of agreement of the methods with nested PCR. Microscopy showed a moderate measure of agreement (k = 0.491), Carestart showed a good measure of agreement (k = 0.611), SD Bioline PF showed a fair measure of agreement (k = 0.226) while SD Bioline PF/PV showed a poor measure of agreement (k = 0.172). Conclusions This study recommends that the policy of malaria diagnosis be changed such that the routine diagnosis of malaria is done by a combination of both microscopy and a RDT kit of high sensitivity and specificity so as to complement the errors associated with either of the methods. The finding of P. ovale in the study area necessitates an expanded molecular epidemiology of malaria within the study area.
Collapse
Affiliation(s)
- Uchenna Iyioku Ugah
- Department of Microbiology, Faculty of Science, Federal University Ndufu-Alike Ikwo, PMB 1010, Abakaliki, Ebonyi State, Nigeria.
| | - Moses Nnaemeka Alo
- Department of Microbiology, Faculty of Science, Federal University Ndufu-Alike Ikwo, PMB 1010, Abakaliki, Ebonyi State, Nigeria
| | - Jacob Oluwabusuyi Owolabi
- Department of Microbiology, Faculty of Science, Federal University Ndufu-Alike Ikwo, PMB 1010, Abakaliki, Ebonyi State, Nigeria
| | - Oluchi DivineGift Okata-Nwali
- Department of Microbiology, Faculty of Science, Federal University Ndufu-Alike Ikwo, PMB 1010, Abakaliki, Ebonyi State, Nigeria
| | - Ifeoma Mercy Ekejindu
- Department of Medical Laboratory Science, Faculty of Health Sciences and Technology, Nnamdi Azikiwe University, Awka, Nigeria
| | - Nancy Ibeh
- Department of Medical Laboratory Science, Faculty of Health Sciences and Technology, Nnamdi Azikiwe University, Awka, Nigeria
| | - Michael Okpara Elom
- Department of Medical Laboratory Science, Faculty of Health Sciences and Technology, Ebonyi State University, Abakaliki, Nigeria
| |
Collapse
|
9
|
Oyeyemi OT, Sode OJ, Adebayo OD, Mensah-Agyei GO. Reliability of rapid diagnostic tests in diagnosing pregnancy and infant-associated malaria in Nigeria. J Infect Public Health 2016; 9:471-477. [PMID: 26738923 DOI: 10.1016/j.jiph.2015.11.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2015] [Revised: 10/31/2015] [Accepted: 11/10/2015] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND The effective management of maternal and infant malaria requires rational and prompt diagnosis. This study aims to determine the diagnostic efficiency of malaria RDT in infants and pregnant women. METHODS The study was conducted on infants (n=200), pregnant women (n=80) and non-pregnant women (n=100) who were recruited from two hospitals in Lagos, Nigeria. Plasmodium falciparum infections were assessed in the febrile subjects by microscopic examinations of blood smears and by RDT. RESULTS The lowest (44.3%) and the highest (83.3%) sensitivity (SS) values were recorded in the infants and pregnant women, respectively. Other diagnostic parameters, including the specificity (SP, 97.5%), positive predictive value (PPV, 92.1%) and negative predictive value (NPV, 72.8%), in the infants were greater than the values recorded in non-pregnant (SP=77.5%, PPV=83.9%, NPV=70.5%) and pregnant women populations (SP=65.6%, PPV=78.4%, NPV=72.4%). The diagnostic efficiency of malaria RDT exhibited higher sensitivity in women in early gestational stages (1st trimester=78.6% and 2nd trimester=88.0%) compared with those in the 3rd trimester (71.4%). The sensitivity of malaria RDT (100.0%) was significantly higher in the multigravid women than in the primigravida (78.6%) and secundigravida women (77.8%, P<0.05). The sensitivity of the RDT significantly increased with the intensity of the malarial parasites (P<0.05). CONCLUSION Malaria is endemic in the study populations. Malaria RDT can serve as a first-line of diagnosis for pregnant women in early gestational stages and multigravid women and can aid the differential diagnoses of other diseases due to its high specificity in infants.
Collapse
Affiliation(s)
- Oyetunde T Oyeyemi
- Department of Biosciences and Biotechnology, Babcock University, Ilishan-Remo, Ogun, Nigeria.
| | - Oluwarotimi J Sode
- Department of Biosciences and Biotechnology, Babcock University, Ilishan-Remo, Ogun, Nigeria
| | - Olalekan D Adebayo
- Department of Biosciences and Biotechnology, Babcock University, Ilishan-Remo, Ogun, Nigeria
| | - Grace O Mensah-Agyei
- Department of Biosciences and Biotechnology, Babcock University, Ilishan-Remo, Ogun, Nigeria
| |
Collapse
|
10
|
Abba K, Kirkham AJ, Olliaro PL, Deeks JJ, Donegan S, Garner P, Takwoingi Y. Rapid diagnostic tests for diagnosing uncomplicated non-falciparum or Plasmodium vivax malaria in endemic countries. Cochrane Database Syst Rev 2014; 2014:CD011431. [PMID: 25519857 PMCID: PMC4453861 DOI: 10.1002/14651858.cd011431] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
BACKGROUND In settings where both Plasmodium vivax and Plasmodium falciparum infection cause malaria, rapid diagnostic tests (RDTs) need to distinguish which species is causing the patients' symptoms, as different treatments are required. Older RDTs incorporated two test lines to distinguish malaria due to P. falciparum, from malaria due to any other Plasmodium species (non-falciparum). These RDTs can be classified according to which antibodies they use: Type 2 RDTs use HRP-2 (for P. falciparum) and aldolase (all species); Type 3 RDTs use HRP-2 (for P. falciparum) and pLDH (all species); Type 4 use pLDH (fromP. falciparum) and pLDH (all species).More recently, RDTs have been developed to distinguish P. vivax parasitaemia by utilizing a pLDH antibody specific to P. vivax. OBJECTIVES To assess the diagnostic accuracy of RDTs for detecting non-falciparum or P. vivax parasitaemia in people living in malaria-endemic areas who present to ambulatory healthcare facilities with symptoms suggestive of malaria, and to identify which types and brands of commercial test best detect non-falciparum and P. vivax malaria. SEARCH METHODS We undertook a comprehensive search of the following databases up to 31 December 2013: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; MEDION; Science Citation Index; Web of Knowledge; African Index Medicus; LILACS; and IndMED. SELECTION CRITERIA Studies comparing RDTs with a reference standard (microscopy or polymerase chain reaction) in blood samples from a random or consecutive series of patients attending ambulatory health facilities with symptoms suggestive of malaria in non-falciparum endemic areas. DATA COLLECTION AND ANALYSIS For each study, two review authors independently extracted a standard set of data using a tailored data extraction form. We grouped comparisons by type of RDT (defined by the combinations of antibodies used), and combined in meta-analysis where appropriate. Average sensitivities and specificities are presented alongside 95% confidence intervals (95% CI). MAIN RESULTS We included 47 studies enrolling 22,862 participants. Patient characteristics, sampling methods and reference standard methods were poorly reported in most studies. RDTs detecting 'non-falciparum' parasitaemiaEleven studies evaluated Type 2 tests compared with microscopy, 25 evaluated Type 3 tests, and 11 evaluated Type 4 tests. In meta-analyses, average sensitivities and specificities were 78% (95% CI 73% to 82%) and 99% (95% CI 97% to 99%) for Type 2 tests, 78% (95% CI 69% to 84%) and 99% (95% CI 98% to 99%) for Type 3 tests, and 89% (95% CI 79% to 95%) and 98% (95% CI 97% to 99%) for Type 4 tests, respectively. Type 4 tests were more sensitive than both Type 2 (P = 0.01) and Type 3 tests (P = 0.03).Five studies compared Type 3 tests with PCR; in meta-analysis, the average sensitivity and specificity were 81% (95% CI 72% to 88%) and 99% (95% CI 97% to 99%) respectively. RDTs detecting P.vivax parasitaemiaEight studies compared pLDH tests to microscopy; the average sensitivity and specificity were 95% (95% CI 86% to 99%) and 99% (95% CI 99% to 100%), respectively. AUTHORS' CONCLUSIONS RDTs designed to detect P. vivax specifically, whether alone or as part of a mixed infection, appear to be more accurate than older tests designed to distinguish P. falciparum malaria from non-falciparum malaria. Compared to microscopy, these tests fail to detect around 5% ofP. vivax cases. This Cochrane Review, in combination with other published information about in vitro test performance and stability in the field, can assist policy-makers to choose between the available RDTs.
Collapse
Affiliation(s)
- Katharine Abba
- Department of Clinical Sciences, Liverpool School of Tropical Medicine, Pembroke Place, Liverpool, UK.
| | | | | | | | | | | | | |
Collapse
|
11
|
Saleh AM, Abdalla HS, Satti AB, Babiker SM, Gasim GI, Adam I. Diagnosis of Trichomonous vaginalis by microscopy, latex agglutination, diamond's media, and PCR in symptomatic women, Khartoum, Sudan. Diagn Pathol 2014; 9:49. [PMID: 24602349 PMCID: PMC3975644 DOI: 10.1186/1746-1596-9-49] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2014] [Accepted: 03/03/2014] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Trichomoniasis is the most common sexually transmitted disease. However, limited data are available on an effective technique for the diagnosis of Trichomonas vaginalis. METHODS A cross-sectional study was conducted to evaluate the accuracy of wet mount microscopy, latex agglutination, Diamond's media, and polymerase chain reaction (PCR) for detection of T. vaginalis among symptomatic women who attended the gynecological clinic at Khartoum, Sudan. RESULTS Of the 297 women studied, 252 (84.8%) were positive for T. vaginalis by wet mount microscopy, 257 (86.5%) by latex agglutination, 253 (85.2%) by Diamond's media, and 253 (85.2%) by PCR. The sensitivity and specificity of wet mount microscopy were 99.2% and 97.7%, respectively, compared with PCR. The sensitivity and specificity of latex agglutination and Diamond's media were 99.6% and 88.6%, and 100.0% and 86.4%, respectively, compared with PCR. CONCLUSIONS In this study, wet mount microscopy, latex agglutination, and Diamond's media were found to be highly sensitive and specific. However, the availability and cost effectiveness might limit the use of Diamond's media and PCR in routine practice. VIRTUAL SLIDES The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7859723851211496.
Collapse
Affiliation(s)
| | | | | | | | | | - Ishag Adam
- Faculty of Medicine, University of Khartoum, Khartoum, Sudan.
| |
Collapse
|
12
|
Haggaz AD, Elbashir LM, Adam GK, Rayis DA, Adam I. Estimating malaria parasite density among pregnant women at central Sudan using actual and assumed white blood cell count. Malar J 2014; 13:6. [PMID: 24386962 PMCID: PMC3893413 DOI: 10.1186/1475-2875-13-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2013] [Accepted: 01/04/2014] [Indexed: 11/11/2022] Open
Abstract
Background Microscopic examination using Giemsa-stained thick blood films remains the reference standard for detection of malaria parasites and it is the only method that is widely and practically available for quantifying malaria parasite density. There are few published data (there was no study during pregnancy) investigating the parasite density (ratio of counted parasites within a given number of microscopic fields against counted white blood cells (WBCs) using actual number of WBCs. Methods Parasitaemia was estimated using assumed WBCs (8,000), which was compared to parasitaemia calculated based on each woman’s WBCs in 98 pregnant women with uncomplicated Plasmodium falciparum malaria at Medani Maternity Hospital, Central Sudan. Results The geometric mean (SD) of the parasite count was 12,014.6 (9,766.5) and 7,870.8 (19,168.8) ring trophozoites /μl, P <0.001 using the actual and assumed (8,000) WBC count, respectively. The median (range) of the ratio between the two parasitaemias (using assumed/actual WBCs) was 1.5 (0.6-5), i e, parasitaemia calculated assuming WBCs equal to median (range) 1.5 (0.6-5) times higher than parasitaemia calculated using actual WBCs. There were 52 out of 98 patients (53%) with ratio between 0.5 and 1.5. For 21 patients (21%) this ratio was higher than 2, and for five patients (5%) it was higher than 3. Conclusion The estimated parasite density using actual WBC counts was significantly lower than the parasite density estimated using assumed WBC counts. Therefore, it is recommended to use the patient`s actual WBC count in the estimation of the parasite density.
Collapse
Affiliation(s)
| | | | | | | | - Ishag Adam
- Faculty of Medicine, University of Khartoum, PO Box 102, Khartoum, Sudan.
| |
Collapse
|
13
|
Batran SE, Salih MM, Elhassan EM, Mohmmed AA, Adam I. CD20, CD3, placental malaria infections and low birth weight in an area of unstable malaria transmission in Central Sudan. Diagn Pathol 2013; 8:189. [PMID: 24245949 PMCID: PMC3937234 DOI: 10.1186/1746-1596-8-189] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2013] [Accepted: 11/13/2013] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Malaria during pregnancy is the main cause of low birth weight (LBW) in the tropics. There are few studies concerning B and T lymphocyte infiltrates in placental malaria infections or their potential association with LBW babies. METHODS A case-control study was conducted at the Medani Hospital, Central Sudan. Cases were women who had LBW deliveries (infants weighed < 2,500 g) and controls were parturient women with normal birth weight babies. Sociodemographic and medical characteristics were gathered from both groups of women using questionnaires. Cases and controls were investigated for malaria using microscopic blood film analysis, placental histology, and immunohistochemistry for detection of B (CD20) and T lymphocytes (CD3). RESULTS The two groups (97 in each arm) were well matched in their basic characteristics. There were no malaria-positive blood films in either the cases or the controls. Twenty-nine (30.0%) vs. 24 (24.7%), P = 0.519 of the cases vs. the controls had placental malaria infections on histological examination. Three (3.1%), two (2.1%) and 24 (24.7%) vs. two (2.1%), two (2.1%) and 20 (20.6%) of the placentae showed evidence of acute, chronic and past malarial infections on histopathological examination of the two groups (case-control), respectively, while 68 (70.1%) vs. 73 (75.3%) of them showed no signs of infection; P = 0.420. Women with placental malaria infections had significantly fewer CD20 cell infiltrates [6 (11.3% vs. 95 (67.4%), P < 0.001)] and higher numbers of CD3 cell infiltrates [50 (94.3%) vs. 42 (29.8%), P < 0.001] than those without placental malaria infection. Logistic regression analysis showed that neither placental malaria infections nor CD3 or CD20 were associated with LBW. CONCLUSIONS Significantly higher rates of CD3 T cells and lower rates of CD20 B cells were found in women with placental malaria infections compared with those without such infections. Neither placental malaria infection nor CD3 or CD20 are associated with LBW. VIRTUAL SLIDES http://www.diagnosticpathology.diagnomx.eu/vs/6879723961063755.
Collapse
Affiliation(s)
| | | | | | | | - Ishag Adam
- Faculty of Medicine, University of Khartoum, Khartoum, Sudan.
| |
Collapse
|