1
|
Orsini E, Bruckert F, Weidenhaupt M, Cugat O, Kauffmann P, Delshadi S. Magnetically Localized Detection of Amplified DNA Using Biotinylated and Fluorescent Primers and Magnetic Nanoparticles. BIOSENSORS 2025; 15:195. [PMID: 40136992 PMCID: PMC11940290 DOI: 10.3390/bios15030195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2025] [Revised: 03/07/2025] [Accepted: 03/14/2025] [Indexed: 03/27/2025]
Abstract
Quantitative nucleic acid detection is widely used in molecular diagnostics for infectious diseases. Here, we demonstrate that the previously developed MLFIA (magnetically localized fluorescent immunoassay) has the potential to detect Polymerase Chain Reaction (PCR) and loop-mediated isothermal amplification (LAMP) products using biotinylated and fluorescent primers and streptavidin-coated magnetic nanoparticles. The functionalized nanoparticles separate amplified DNA from non-incorporated primers in situ, allowing the quantification of DNA products. We compare magnetically localized fluorescence detection to commercial technologies based on the DNA intercalation of fluorescent dyes. Our system allows the detection of PCR and LAMP products but is approximately 10 times less sensitive than standard commercial assays. Future optimizations, such as enhancing the signal-to-noise ratio and improving nanoparticle functionalization, could significantly increase sensitivity and bring it closer to current diagnostic standards. This work highlights the potential of magnetically localized fluorescence detection to detect DNA.
Collapse
Affiliation(s)
- Etienne Orsini
- MagIA Diagnostics, 15 Rue Maréchal Leclerc, 38130 Échirolles, France; (P.K.); (S.D.)
- Univ. Grenoble Alpes, Centre National de la Recherche Scientifique Grenoble Institut National Polytechnique, Laboratoire des Matériaux et du Génie Physique, 38000 Grenoble, France (M.W.)
| | - Franz Bruckert
- Univ. Grenoble Alpes, Centre National de la Recherche Scientifique Grenoble Institut National Polytechnique, Laboratoire des Matériaux et du Génie Physique, 38000 Grenoble, France (M.W.)
| | - Marianne Weidenhaupt
- Univ. Grenoble Alpes, Centre National de la Recherche Scientifique Grenoble Institut National Polytechnique, Laboratoire des Matériaux et du Génie Physique, 38000 Grenoble, France (M.W.)
| | - Orphée Cugat
- Univ. Grenoble Alpes, Centre National de la Recherche Scientifique, Grenoble Institut National Polytechnique, G2Elab, 38000 Grenoble, France;
| | - Paul Kauffmann
- MagIA Diagnostics, 15 Rue Maréchal Leclerc, 38130 Échirolles, France; (P.K.); (S.D.)
| | - Sarah Delshadi
- MagIA Diagnostics, 15 Rue Maréchal Leclerc, 38130 Échirolles, France; (P.K.); (S.D.)
| |
Collapse
|
2
|
Yalley AK, Ocran J, Cobbinah JE, Obodai E, Yankson IK, Kafintu-Kwashie AA, Amegatcher G, Anim-Baidoo I, Nii-Trebi NI, Prah DA. Advances in Malaria Diagnostic Methods in Resource-Limited Settings: A Systematic Review. Trop Med Infect Dis 2024; 9:190. [PMID: 39330879 PMCID: PMC11435979 DOI: 10.3390/tropicalmed9090190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 07/31/2024] [Accepted: 08/19/2024] [Indexed: 09/28/2024] Open
Abstract
Malaria continues to pose a health challenge globally, and its elimination has remained a major topic of public health discussions. A key factor in eliminating malaria is the early and accurate detection of the parasite, especially in asymptomatic individuals, and so the importance of enhanced diagnostic methods cannot be overemphasized. This paper reviewed the advances in malaria diagnostic tools and detection methods over recent years. The use of these advanced diagnostics in lower and lower-middle-income countries as compared to advanced economies has been highlighted. Scientific databases such as Google Scholar, PUBMED, and Multidisciplinary Digital Publishing Institute (MDPI), among others, were reviewed. The findings suggest important advancements in malaria detection, ranging from the use of rapid diagnostic tests (RDTs) and molecular-based technologies to advanced non-invasive detection methods and computerized technologies. Molecular tests, RDTs, and computerized tests were also seen to be in use in resource-limited settings. In all, only twenty-one out of a total of eighty (26%) low and lower-middle-income countries showed evidence of the use of modern malaria diagnostic methods. It is imperative for governments and other agencies to direct efforts toward malaria research to upscale progress towards malaria elimination globally, especially in endemic regions, which usually happen to be resource-limited regions.
Collapse
Affiliation(s)
- Akua K. Yalley
- Department of Medical Laboratory Sciences, School of Biomedical and Allied Health Sciences, University of Ghana, Korle Bu, Accra P.O. Box KB 143, Ghana; (A.K.Y.); (A.A.K.-K.); (G.A.); (I.A.-B.)
| | - Joyous Ocran
- Department of Biomedical Sciences, School of Allied Health Sciences, University of Cape Coast, PMB, Cape Coast, Ghana; (J.O.); (J.E.C.)
| | - Jacob E. Cobbinah
- Department of Biomedical Sciences, School of Allied Health Sciences, University of Cape Coast, PMB, Cape Coast, Ghana; (J.O.); (J.E.C.)
| | - Evangeline Obodai
- Department of Virology, Noguchi Memorial Institute for Medical Research, University of Ghana, Accra P.O. Box LG 581, Ghana;
| | - Isaac K. Yankson
- CSIR-Building and Road Research Institute, Kumasi P.O. Box UP40, Kumasi, Ghana;
| | - Anna A. Kafintu-Kwashie
- Department of Medical Laboratory Sciences, School of Biomedical and Allied Health Sciences, University of Ghana, Korle Bu, Accra P.O. Box KB 143, Ghana; (A.K.Y.); (A.A.K.-K.); (G.A.); (I.A.-B.)
| | - Gloria Amegatcher
- Department of Medical Laboratory Sciences, School of Biomedical and Allied Health Sciences, University of Ghana, Korle Bu, Accra P.O. Box KB 143, Ghana; (A.K.Y.); (A.A.K.-K.); (G.A.); (I.A.-B.)
| | - Isaac Anim-Baidoo
- Department of Medical Laboratory Sciences, School of Biomedical and Allied Health Sciences, University of Ghana, Korle Bu, Accra P.O. Box KB 143, Ghana; (A.K.Y.); (A.A.K.-K.); (G.A.); (I.A.-B.)
| | - Nicholas I. Nii-Trebi
- Department of Medical Laboratory Sciences, School of Biomedical and Allied Health Sciences, University of Ghana, Korle Bu, Accra P.O. Box KB 143, Ghana; (A.K.Y.); (A.A.K.-K.); (G.A.); (I.A.-B.)
| | - Diana A. Prah
- West African Centre for Cell Biology of Infectious Pathogens, University of Ghana, Legon, Accra P.O. Box LG 54, Ghana
- Department of Science Laboratory Technology, Faculty of Applied Sciences, Accra Technical University, Barnes Road, Accra P.O. Box GP 561, Ghana
| |
Collapse
|
3
|
T R, C D, A R, Jc Y. Nine years of imported malaria in a teaching hospital in Belgium: Demographics, clinical characteristics, and outcomes. Diagn Microbiol Infect Dis 2024; 108:116206. [PMID: 38335879 DOI: 10.1016/j.diagmicrobio.2024.116206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/06/2023] [Accepted: 01/30/2024] [Indexed: 02/12/2024]
Abstract
BACKGROUND Imported malaria is often misdiagnosed due to the aspecific symptoms and lack of familiarity among clinicians. This study aims to evaluate a decade-long trend of imported malaria cases in a Belgian teaching hospital by analyzing demographics, clinical characteristics, and outcomes. METHODS Medical records of 223 patients with confirmed malaria diagnoses between 2010 and 2019 were analyzed. RESULTS Most patients were male (63.2%), aged 18-65 years (77.1%), and visiting friends or relatives (40.8%). Central Africa was the most common travel destination (54.3%), and 63.7% did not take prophylaxis. Symptoms were flu-like, with fever (91.9%) being most prevalent. P. falciparum was identified in 88.3% of cases. A high proportion of severe cases (41.7%) and a low mortality rate (0.9%) were recorded. A severe form of the disease is associated with a more extended hospital stay than uncomplicated form (median of 5 vs. 4 days, p < 0.001). Thirty-five-point five percent [33/93] of patients with severe malaria have had a previous malaria infection compared to 50.8% [66/130] of uncomplicated patients (p= 0.013) wich was statistically significant. CONCLUSION Malaria disproportionately affects VFRs traveling to Central Africa, and flu-like symptoms should raise suspicion. Prophylaxis is essential to prevent the disease, and early diagnosis is critical for effective management. A severe form of the disease is associated with a more extended hospital stay than uncomplicated form and people with a previous history of malaria have a less severe disease.
Collapse
Affiliation(s)
- Ratovonjanahary T
- Epidemiology and Biostatistics Unit, Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium
| | - Danwang C
- Clinton Health Access Initiative, Inc., Boston, MA, USA
| | - Robert A
- Epidemiology and Biostatistics Unit, Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium
| | - Yombi Jc
- Department of Internal Medicine and Infectious Diseases, Cliniques Universitaires Saint-Luc, Université Catholique de Louvain, Brussels, Belgium; Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium.
| |
Collapse
|
4
|
Martín Ramírez A, Barón Argos L, Lanza Suárez M, Carmona Rubio C, Pérez-Ayala A, Hisam SR, Rubio JM. Malaria diagnosis using a combined system of a simple and fast extraction method with a lyophilised Dual-LAMP assay in a non-endemic setting. Pathog Glob Health 2024; 118:80-90. [PMID: 37415348 PMCID: PMC10769111 DOI: 10.1080/20477724.2023.2232595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023] Open
Abstract
Malaria is a parasitic disease distributed in tropical areas but with a high number of imported cases in non-endemic countries. The most specific and sensitive malaria diagnostic methods are PCR and LAMP. However, both require specific equipment, extraction procedures and a cold chain. This study aims to solve some limitations of LAMP method with the optimization and validation of six LAMP assays, genus and species-specific, using an easy and fast extraction method, the incorporation of a reaction control assay, two ways (Dual) of result reading and reagent lyophilization. The Dual-LAMP assays were validated against the Nested-Multiplex Malaria PCR. A conventional column and saline extraction methods, and the use of lyophilized reaction tubes were also assessed. A new reaction control Dual-LAMP-RC assay was designed. Dual-LAMP-Pspp assay showed no cross-reactivity with other parasites, repeatability and reproducibility of 100%, a significant correlation between parasite concentration and time to amplification and a LoD of 1.22 parasites/µl and 5.82 parasites/µl using column and saline extraction methods, respectively. Sensitivity and specificity of the six Dual-LAMP assays reach values of 100% or close to this, being lower for the Dual-LAMP-Pm. The Dual-LAMP-RC assay worked as expected. Lyophilized Dual-LAMP results were concordant with the reference method. Dual-LAMP malaria assays with the addition of a new reaction control LAMP assay and the use of a fast and easy saline extraction method, provided low limit of detection, no cross-reactivity, and good sensitivity and specificity. Furthermore, the reagent lyophilization and the dual result reading allow their use in most settings.
Collapse
Affiliation(s)
- Alexandra Martín Ramírez
- Malaria & Parasitic Emerging Diseases Laboratory. National Microbiology Center, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
- Centro de Investigación Biomédica En Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| | - Lourdes Barón Argos
- Malaria & Parasitic Emerging Diseases Laboratory. National Microbiology Center, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| | - Marta Lanza Suárez
- Malaria & Parasitic Emerging Diseases Laboratory. National Microbiology Center, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| | - Claudia Carmona Rubio
- Malaria & Parasitic Emerging Diseases Laboratory. National Microbiology Center, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| | - Ana Pérez-Ayala
- Department of Clinical Microbiology, Hospital Universitario 12 de Octubre, Madrid, Spain
| | - Shamilah R. Hisam
- Parasitology Unit, Infectious Disease Research Centre, Institute for Medical Research, National Institute of Health, Setia Alam, Selangor, Malaysia
| | - José M. Rubio
- Malaria & Parasitic Emerging Diseases Laboratory. National Microbiology Center, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
- Centro de Investigación Biomédica En Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
5
|
Calderaro A, Piccolo G, Chezzi C. The Laboratory Diagnosis of Malaria: A Focus on the Diagnostic Assays in Non-Endemic Areas. Int J Mol Sci 2024; 25:695. [PMID: 38255768 PMCID: PMC10815132 DOI: 10.3390/ijms25020695] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/26/2023] [Accepted: 01/03/2024] [Indexed: 01/24/2024] Open
Abstract
Even if malaria is rare in Europe, it is a medical emergency and programs for its control should ensure both an early diagnosis and a prompt treatment within 24-48 h from the onset of the symptoms. The increasing number of imported malaria cases as well as the risk of the reintroduction of autochthonous cases encouraged laboratories in non-endemic countries to adopt diagnostic methods/algorithms. Microscopy remains the gold standard, but with limitations. Rapid diagnostic tests have greatly expanded the ability to diagnose malaria for rapid results due to simplicity and low cost, but they lack sensitivity and specificity. PCR-based assays provide more relevant information but need well-trained technicians. As reported in the World Health Organization Global Technical Strategy for Malaria 2016-2030, the development of point-of-care testing is important for the improvement of diagnosis with beneficial consequences for prompt/accurate treatment and for preventing the spread of the disease. Despite their limitations, diagnostic methods contribute to the decline of malaria mortality. Recently, evidence suggested that artificial intelligence could be utilized for assisting pathologists in malaria diagnosis.
Collapse
Affiliation(s)
- Adriana Calderaro
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (G.P.); (C.C.)
| | | | | |
Collapse
|
6
|
Akafity G, Kumi N, Ashong J. Diagnosis and management of malaria in the intensive care unit. JOURNAL OF INTENSIVE MEDICINE 2024; 4:3-15. [PMID: 38263976 PMCID: PMC10800773 DOI: 10.1016/j.jointm.2023.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 08/17/2023] [Accepted: 09/02/2023] [Indexed: 01/25/2024]
Abstract
Malaria is responsible for approximately three-quarters of a million deaths in humans globally each year. Most of the morbidity and mortality reported are from Sub-Saharan Africa and Asia, where the disease is endemic. In non-endemic areas, malaria is the most common cause of imported infection and is associated with significant mortality despite recent advancements and investments in elimination programs. Severe malaria often requires intensive care unit admission and can be complicated by cerebral malaria, respiratory distress, acute kidney injury, bleeding complications, and co-infection. Intensive care management includes prompt diagnosis and early initiation of effective antimalarial therapy, recognition of complications, and appropriate supportive care. However, the lack of diagnostic capacities due to limited advances in equipment, personnel, and infrastructure presents a challenge to the effective diagnosis and management of malaria. This article reviews the clinical classification, diagnosis, and management of malaria as relevant to critical care clinicians, highlighting the role of diagnostic capacity, treatment options, and supportive care.
Collapse
Affiliation(s)
- George Akafity
- Department of Research, Monitoring, and Evaluation, Cape Coast Teaching Hospital, Cape Coast, Ghana
| | - Nicholas Kumi
- Intensive Care Unit, Department of Critical Care and Anesthesia, Cape Coast Teaching Hospital, Cape Coast, Ghana
| | - Joyce Ashong
- Department of Paediatrics and Child Health, Cape Coast Teaching Hospital, Cape Coast, Ghana
| |
Collapse
|
7
|
Ivarsson AC, Fransén E, Broumou I, Färnert A, Persson KEM, Söbirk SK. Head-to-head comparison of two loop-mediated isothermal amplification (LAMP) kits for diagnosis of malaria in a non-endemic setting. Malar J 2023; 22:377. [PMID: 38093251 PMCID: PMC10717323 DOI: 10.1186/s12936-023-04809-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 11/28/2023] [Indexed: 12/17/2023] Open
Abstract
BACKGROUND Light microscopy and rapid diagnostic tests (RDT) have long been the recommended diagnostic methods for malaria. However, in recent years, loop-mediated isothermal amplification (LAMP) techniques have been shown to offer superior performance, in particular concerning low-grade parasitaemia, by delivering higher sensitivity and specificity with low laboratory capacity requirements in little more than an hour. In this study, the diagnostic performance of two LAMP kits were assessed head-to-head, compared to highly sensitive quantitative real time PCR (qPCR), in a non-endemic setting. METHODS In this retrospective validation study two LAMP kits; Alethia® Illumigene Malaria kit and HumaTurb Loopamp™ Malaria Pan Detection (PDT) kit, were evaluated head-to-head for detection of Plasmodium-DNA in 133 biobanked blood samples from suspected malaria cases at the Clinical Microbiology Laboratory of Region Skåne, Sweden to determine their diagnostic performance compared to qPCR. RESULTS Of the 133 samples tested, qPCR detected Plasmodium DNA in 41 samples (defined as true positives), and the two LAMP methods detected 41 and 37 of those, respectively. The results from the HumaTurb Loopamp™ Malaria PDT kit were in complete congruence with the qPCR, with a sensitivity of 100% (95% CI 91.40-100%) and specificity of 100% (95% CI 96.07-100%). The Alethia® Illumigene Malaria kit had a sensitivity of 90.24% (95% CI 76.87-97.28) and a specificity of 95.65% (95% CI 89.24-98.80) as compared to qPCR. CONCLUSIONS This head-to-head comparison showed higher performance indicators of the HumaTurb Loopamp™ Malaria PDT kit compared to the Alethia® illumigene Malaria kit for detection of malaria.
Collapse
Affiliation(s)
- Anna-Clara Ivarsson
- Clinical Microbiology, Infection Prevention and Control, Office for Medical Services, Region Skåne, Lund, Sweden.
| | - Elin Fransén
- Clinical Microbiology, Infection Prevention and Control, Office for Medical Services, Region Skåne, Lund, Sweden
| | - Ioanna Broumou
- Department of Medicine Solna, Karolinska Institute, Stockholm, Sweden
- Centre for Molecular Medicine, Stockholm, Sweden
| | - Anna Färnert
- Department of Medicine Solna, Karolinska Institute, Stockholm, Sweden
- Centre for Molecular Medicine, Stockholm, Sweden
- Department of Infectious Diseases, Karolinska University Hospital, Stockholm, Sweden
| | - Kristina E M Persson
- Division of Clinical Chemistry and Pharmacology, Department of Laboratory Medicine, Lund University, Lund, Sweden
- Clinical Chemistry and Pharmacology, Laboratory Medicine, Office for Medical Services, Region Skåne, Lund, Sweden
| | - Sara Karlsson Söbirk
- Clinical Microbiology, Infection Prevention and Control, Office for Medical Services, Region Skåne, Lund, Sweden
- Division of Infection Medicine, Department of Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
8
|
Martín-Ramírez A, Lanza M, Hisam S, Perez-Ayala A, Rubio JM. Usefulness of a commercial LAMP assay for detection of malaria infection, including Plasmodium knowlesi cases, in returning travelers in Spain. BMC Res Notes 2022; 15:147. [PMID: 35468833 PMCID: PMC9036737 DOI: 10.1186/s13104-022-06037-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 04/11/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Objective
Main malaria diagnosis is based on microscopic examination combined with rapid diagnostic tests. Both methods have low sensitivity and specificity. Loop-mediated isothermal amplification techniques have shown a sensitivity similar to PCR but with lower times of performance. This study aimed to assess a commercial LAMP for the diagnosis of malaria (Alethia® Malaria) against the Nested-Multiplex-Malaria PCR, including the analytical sensitivity and the operational characteristics.
Results
One hundred five samples out of 114 rendered valid results, obtaining 85 positive samples and 18 negative samples with an agreement of 98% compared to the reference method with a sensitivity, specificity and kappa coefficient of 98.84%, 94.74% and 0.94 respectively, with only two discrepant samples. The turnaround time was estimated in 1 h and 30 min, with a cost of 32.67€ per determination. The results showed several advantages of the Alethia® Malaria, as it was easy to perform, minimal training requirement and 40 min run. Moreover, it includes an internal control to avoid false negatives. However, it also showed some limitations such as the need for a specific amplification and detection device, the detection of only Plasmodium spp. and a very high price.
Collapse
|
9
|
Fitri LE, Widaningrum T, Endharti AT, Prabowo MH, Winaris N, Nugraha RYB. Malaria diagnostic update: From conventional to advanced method. J Clin Lab Anal 2022; 36:e24314. [PMID: 35247002 PMCID: PMC8993657 DOI: 10.1002/jcla.24314] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 02/11/2022] [Accepted: 02/16/2022] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND Update diagnostic methods play essential roles in dealing with the current global malaria situation and decreasing malaria incidence. AIM Global malaria control programs require the availability of adequate laboratory tests in the quick and convenient field. RESULTS There are several methods to find out the existence of parasites within the blood. The oldest one is by microscopy, which is still a gold standard, although rapid diagnostic tests (RDTs) have rapidly become a primary diagnostic test in many endemic areas. Because of microscopy and RDTs limitation, novel serological and molecular methods have been developed. Many kinds of polymerase chain reaction (PCR) provide rapid results and higher specificity and sensitivity. The loop-mediated isothermal amplification (LAMP) and biosensing-based molecular techniques as point of care tests (POCT) will become a cost-effective approach to advance diagnostic testing. CONCLUSION Despite conventional techniques are still being used in the field, the exploration and field implementation of advanced techniques for the diagnosis of malaria are still being developed rapidly.
Collapse
Affiliation(s)
- Loeki Enggar Fitri
- Department of ParasitologyFaculty of Medicine Universitas BrawijayaMalangIndonesia
- Malaria Research GroupFaculty of Medicine Universitas BrawijayaMalangIndonesia
| | - Tarina Widaningrum
- Malaria Research GroupFaculty of Medicine Universitas BrawijayaMalangIndonesia
- Department of PharmacologyFaculty of Medicine Universitas BrawijayaMalangIndonesia
| | | | | | - Nuning Winaris
- Department of ParasitologyFaculty of Medicine Universitas BrawijayaMalangIndonesia
- Malaria Research GroupFaculty of Medicine Universitas BrawijayaMalangIndonesia
| | - Rivo Yudhinata Brian Nugraha
- Department of ParasitologyFaculty of Medicine Universitas BrawijayaMalangIndonesia
- Malaria Research GroupFaculty of Medicine Universitas BrawijayaMalangIndonesia
| |
Collapse
|
10
|
Martín-Ramírez A, Lanza-Suárez M, Muñoz-García C, Hisam SR, Perez-Ayala A, Rubio JM. Usefulness of Malachite-Green LAMP for Diagnosis of Plasmodium and Five Human Malaria Species in a Nonendemic Setting. Am J Trop Med Hyg 2022; 106:tpmd211151. [PMID: 35292597 PMCID: PMC9128691 DOI: 10.4269/ajtmh.21-1151] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 12/22/2021] [Indexed: 11/07/2022] Open
Abstract
Molecular methods are necessary to detect low-density malaria infections. The purpose of this study was to assess the diagnostic performance of six malachite-green loop-mediated amplification method (MG-LAMP) assays (MG-LAMP-Pf, MG-LAMP-Pv, MG-LAMP-Po, MG-LAMP-Pm, MG-LAMP-Pk, and MG-LAMP-Pspp) for the species-specific detection of each human Plasmodium, including P. knowlesi, and the Plasmodium genus compared with the nested-multiplex malaria polymerase chain reaction (NM-PCR), using 161 malaria-positive and 274 malaria-negative samples. MG-LAMP-Pspp assay detected the five human Plasmodium species and each species-specific MG-LAMP assay detected only its corresponding species. Sensitivity, specificity, and predictive values of MG-LAMP assays, compared with NM-PCR, were > 90%, except in the case of the MG-LAMP-Pm assay, which dropped to 47%. Limit of detection for MG-LAMP-Pspp assay ranged from 0.1 parasites/µL for P. falciparum to 16.9 parasites/µL for P. malariae samples, and it was similar for the rest of MG-LAMP assays except for the MG-LAMP-Pm assay. Turnaround time was estimated to be 2 hours and 35 minutes for one MG-LAMP assay and 4 hours and 15 minutes if all species-specific MG-LAMP is set up, whereas for the NM-PCR, turnaround time was ∼6 hours and 15 minutes. Costs per determination ranged from 1 to 6 euros for MG-LAMP assays and 5 euros for NM-PCR. Therefore, MG-LAMP assays appear to have good concordance compared with the reference method, except for the MG-LAMP-Pm assay. They can detect low parasitemia and identify malaria species, with lower costs and shorter time to obtain results, and they are suitable tools to be used in endemic and non-endemic countries for malaria detection.
Collapse
Affiliation(s)
- Alexandra Martín-Ramírez
- Malaria and Emerging Parasitic Diseases Laboratory, National Microbiology Centre, Instituto de Salud Carlos III, Madrid, Spain
| | - Marta Lanza-Suárez
- Malaria and Emerging Parasitic Diseases Laboratory, National Microbiology Centre, Instituto de Salud Carlos III, Madrid, Spain
| | - Carlota Muñoz-García
- Malaria and Emerging Parasitic Diseases Laboratory, National Microbiology Centre, Instituto de Salud Carlos III, Madrid, Spain
| | - Shamilah R. Hisam
- Parasitology Unit, Infectious Disease Research Centre, Institute for Medical Research, National Institute of Health, Ministry of Health Malaysia, Setia Alam, Selangor, Malaysia
| | - Ana Perez-Ayala
- Department of Clinical Microbiology, Hospital Universitario 12 de Octubre, Madrid, Spain
| | - José M. Rubio
- Malaria and Emerging Parasitic Diseases Laboratory, National Microbiology Centre, Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
11
|
Ozturk EA, Caner A. Liquid Biopsy for Promising Non-invasive Diagnostic Biomarkers in Parasitic Infections. Acta Parasitol 2022; 67:1-17. [PMID: 34176040 DOI: 10.1007/s11686-021-00444-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 06/16/2021] [Indexed: 02/06/2023]
Abstract
BACKGROUND Liquid biopsy refers to the sampling and molecular analysis of body fluids such as blood, saliva, and urine in contrast to conventional tissue biopsies. Liquid biopsy approach can offer powerful non-invasive biomarkers (circulating markers) for diagnosis and monitoring treatment response of a variety of diseases, including parasitic infections. METHODS In this review, we concentrate on cell-free DNA (cfDNA), microRNA (miRNA), and exosomes in the published literature. RESULTS Considering the high prevalence and severity of parasitic infections worldwide, circulating biomarkers can provide a new insight into the diagnosis and prognosis of parasites in the near future. Moreover, identifying and characterizing parasite- or host-derived circulating markers are important for a better understanding of the pathogenesis of parasite infection and host-parasite relationship at the molecular level. Profiling of biomarkers for parasitic diseases is a promising potential field, though further studies and optimization strategies are required, both in vitro and in vivo. CONCLUSION In this review, we discuss three approaches in the liquid biopsy including circulating cfDNA, miRNAs, and exosomes for diagnosis and evaluation of parasites and summarize circulating biomarkers in non-invasive samples during parasitic infections.
Collapse
Affiliation(s)
- Eylem Akdur Ozturk
- Department of Parasitology, Çukurova University Faculty of Medicine, Adana, Turkey
| | - Ayse Caner
- Department of Parasitology, Ege University Faculty of Medicine, 35100, Izmir, Turkey.
- Cancer Research Center, Ege University, Izmir, Turkey.
| |
Collapse
|
12
|
Antinori S, Ridolfo AL, Grande R, Galimberti L, Casalini G, Giacomelli A, Milazzo L. Loop-mediated isothermal amplification (LAMP) assay for the diagnosis of imported malaria: a narrative review. LE INFEZIONI IN MEDICINA 2022; 29:355-365. [PMID: 35146340 DOI: 10.53854/liim-2903-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 08/09/2021] [Indexed: 11/03/2022]
Abstract
Loop-mediated isothermal amplification (LAMP) is a molecular method to detect malaria recently introduced in the market. LAMP is simple to perform and does not require advanced equipment and training thus satisfying the qualification as a point-of-care diagnostic screening test. In this narrative review, we focus on the role of LAMP for malaria diagnosis in non-endemic settings. We searched PubMed, Embase, Scopus, and Google Scholar, using the following search terms: 'Malaria LAMP' in combination with 'imported malaria' or 'travellers' malaria' or 'non-endemic setting' or 'non-endemic region' or 'malaria screening' or 'malaria diagnosis'. References of each article were also reviewed for possible studies or reports not identified in our search. Overall, 18 studies encompassing 6289 tested samples with 1663 confirmed malaria diagnoses were retrieved. Most of these studies (13/18, 72.2%) were conducted in Europe, and almost half were retrospective. Fourteen studies (77.8%) employed real-time or nested-polymerase chain reaction as the reference method for confirming malaria diagnosis. Sensitivity of LAMP ranged from 93.9 to 100% and specificity from 93.8 to 100% with a negative predictive value of 99.6%-100%. The rate of reported invalid results requiring repeat of the test varied from 0.01% to 5.7%, but they were solved in the majority of cases with a secondary analysis. In non-endemic countries the adoption of LAMP malaria assay as the screening test for malaria diagnosis seems to perform better than conventional methods. However, blood microscopy remains essential to either identify Plasmodium species and quantify parasitaemia and adequately managing malaria cases.
Collapse
Affiliation(s)
- Spinello Antinori
- Department of Biomedical and Clinical Sciences "Luigi Sacco", Università degli Studi di Milano, Milano, Italy.,III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Anna Lisa Ridolfo
- III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Romualdo Grande
- Clinical Microbiology, Virology and Bioemergency, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Laura Galimberti
- III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Giacomo Casalini
- Department of Biomedical and Clinical Sciences "Luigi Sacco", Università degli Studi di Milano, Milano, Italy
| | - Andrea Giacomelli
- Department of Biomedical and Clinical Sciences "Luigi Sacco", Università degli Studi di Milano, Milano, Italy.,III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| | - Laura Milazzo
- III Division of Infectious Diseases, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Milano, Italy
| |
Collapse
|
13
|
Calderaro A, Montecchini S, Buttrini M, Piccolo G, Rossi S, Arcangeletti MC, Farina B, De Conto F, Chezzi C. Malaria Diagnosis in Non-Endemic Settings: The European Experience in the Last 22 Years. Microorganisms 2021; 9:microorganisms9112265. [PMID: 34835391 PMCID: PMC8620059 DOI: 10.3390/microorganisms9112265] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 10/25/2021] [Accepted: 10/26/2021] [Indexed: 11/16/2022] Open
Abstract
Accurate, prompt, and reliable tools for the diagnosis of malaria are crucial for tracking the successes or drawbacks of control and elimination efforts, and for future programs aimed at global malaria eradication. Although microscopy remains the gold standard method, the number of imported malaria cases and the risk of reappearance of autochthonous cases stimulated several laboratories located in European countries to evaluate methods and algorithms suited to non-endemic settings, where skilled microscopists are not always available. In this review, an overview of the field evaluation and a comparison of the methods used for the diagnosis of malaria by European laboratories is reported, showing that the development of numerous innovations is continuous. In particular, the combination of rapid diagnostic tests and molecular assays with microscopy represents a reliable system for the early diagnosis of malaria in non-endemic settings.
Collapse
Affiliation(s)
- Adriana Calderaro
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
- Correspondence: ; Tel.: +39-0521-033499; Fax: +39-0521-993620
| | - Sara Montecchini
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Mirko Buttrini
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Giovanna Piccolo
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Sabina Rossi
- Unit of Clinical Microbiology, University Hospital of Parma, Viale A. Gramsci 14, 43126 Parma, Italy;
| | - Maria Cristina Arcangeletti
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Benedetta Farina
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Flora De Conto
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| | - Carlo Chezzi
- Department of Medicine and Surgery, University of Parma, Viale A. Gramsci 14, 43126 Parma, Italy; (S.M.); (M.B.); (G.P.); (M.C.A.); (B.F.); (F.D.C.); (C.C.)
| |
Collapse
|
14
|
Barazorda KA, Salas CJ, Braga G, Ricopa L, Ampuero JS, Siles C, Sanchez JF, Montano S, Lizewski SE, Joya CA, Bishop DK, Valdivia HO. Validation study of Boil & Spin Malachite Green Loop Mediated Isothermal Amplification (B&S MG-LAMP) versus microscopy for malaria detection in the Peruvian Amazon. PLoS One 2021; 16:e0258722. [PMID: 34695122 PMCID: PMC8544869 DOI: 10.1371/journal.pone.0258722] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 10/04/2021] [Indexed: 11/19/2022] Open
Abstract
Malaria elimination efforts in Peru have dramatically reduced the incidence of cases in the Amazon Basin. To achieve the elimination, the detection of asymptomatic and submicroscopic carriers becomes a priority. Therefore, efforts should focus on tests sensitive enough to detect low-density parasitemia, deployable to resource-limited areas and affordable for large screening purposes. In this study, we assessed the performance of the Malachite–Green LAMP (MG-LAMP) using heat-treated DNA extraction (Boil & Spin; B&S MG-LAMP) on 283 whole blood samples collected from 9 different sites in Loreto, Peru and compared its performance to expert and field microscopy. A real-time PCR assay was used to quantify the parasite density. In addition, we explored a modified version of the B&S MG-LAMP for detection of submicroscopic infection in 500 samples and compared the turnaround time and cost of the MG-LAMP with microscopy. Compared to expert microscopy, the genus B&S MG-LAMP had a sensitivity of 99.4% (95%CI: 96.9%– 100%) and specificity of 97.1% (95%CI: 91.9%– 99.4%). The P. vivax specific B&S MG-LAMP had a sensitivity of 99.4% (96.6%– 100%) and specificity of 99.2% (95.5%– 100%) and the P. falciparum assay had a sensitivity of 100% (95%CI: 78.2%– 100%) and specificity of 99.3% (95%CI: 97.3%– 99.8%). The modified genus B&S MG-LAMP assay detected eight submicroscopic malaria cases (1.6%) which the species-specific assays did not identify. The turnaround time of B&S MG-LAMP was faster than expert microscopy with as many as 60 samples being processed per day by field technicians with limited training and utilizing a simple heat-block. The modified B&S MG-LAMP offers a simple and sensitive molecular test of choice for the detection of submicroscopic infections that can be used for mass screening in resources limited facilities in endemic settings nearing elimination and where a deployable test is required.
Collapse
Affiliation(s)
| | - Carola J. Salas
- Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Greys Braga
- Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Leonila Ricopa
- Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Julia S. Ampuero
- Department of Virology and Emerging infections, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Crystyan Siles
- Department of Virology and Emerging infections, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Juan F. Sanchez
- Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Silvia Montano
- Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Stephen E. Lizewski
- Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Christie A. Joya
- Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Danett K. Bishop
- Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
| | - Hugo O. Valdivia
- Department of Parasitology, U.S. Naval Medical Research Unit N°6 (NAMRU-6), Lima, Peru
- * E-mail:
| |
Collapse
|
15
|
Field validation of a magneto-optical detection device (Gazelle) for portable point-of-care Plasmodium vivax diagnosis. PLoS One 2021; 16:e0253232. [PMID: 34157032 PMCID: PMC8219132 DOI: 10.1371/journal.pone.0253232] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 05/31/2021] [Indexed: 12/17/2022] Open
Abstract
A major challenge for malaria is the lack of tools for accurate and timely diagnosis in the field which are critical for case management and surveillance. Microscopy along with rapid diagnostic tests are the current mainstay for malaria diagnosis in most endemic regions. However, these methods present several limitations. This study assessed the accuracy of Gazelle, a novel rapid malaria diagnostic device, from samples collected from the Peruvian Amazon between 2019 and 2020. Diagnostic accuracy was compared against microscopy and two rapid diagnostic tests (SD Bioline and BinaxNOW) using 18ssr nested-PCR as reference test. In addition, a real-time PCR assay (PET-PCR) was used for parasite quantification. Out of 217 febrile patients enrolled and tested, 180 specimens (85 P. vivax and 95 negatives) were included in the final analysis. Using nested-PCR as the gold standard, the sensitivity and specificity of Gazelle was 88.2% and 97.9%, respectively. Using a cutoff of 200 parasites/μl, Gazelle’s sensitivity for samples with more than 200 p/uL was 98.67% (95%CI: 92.79% to 99.97%) whereas the sensitivity for samples lower than 200 p/uL (n = 10) was 12.5% (95%CI: 0.32% to 52.65%). Gazelle’s sensitivity and specificity were statistically similar to microscopy (sensitivity = 91.8, specificity = 100%, p = 0.983) and higher than both SD Bioline (sensitivity = 82.4, specificity = 100%, p = 0.016) and BinaxNOW (sensitivity = 71.8%, specificity = 97.9%, p = 0.002). The diagnostic accuracy of Gazelle for malaria detection in P. vivax infections was comparable to light microscopy and superior to both RDTs even in the presence of low parasitemia infections. The performance of Gazelle makes it a valuable tool for malaria diagnosis and active case detection that can be utilized in different malaria-endemic regions.
Collapse
|
16
|
Gimenez AM, Marques RF, Regiart M, Bargieri DY. Diagnostic Methods for Non-Falciparum Malaria. Front Cell Infect Microbiol 2021; 11:681063. [PMID: 34222049 PMCID: PMC8248680 DOI: 10.3389/fcimb.2021.681063] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 05/31/2021] [Indexed: 11/13/2022] Open
Abstract
Malaria is a serious public health problem that affects mostly the poorest countries in the world, killing more than 400,000 people per year, mainly children under 5 years old. Among the control and prevention strategies, the differential diagnosis of the Plasmodium-infecting species is an important factor for selecting a treatment and, consequently, for preventing the spread of the disease. One of the main difficulties for the detection of a specific Plasmodium sp is that most of the existing methods for malaria diagnosis focus on detecting P. falciparum. Thus, in many cases, the diagnostic methods neglect the other non-falciparum species and underestimate their prevalence and severity. Traditional methods for diagnosing malaria may present low specificity or sensitivity to non-falciparum spp. Therefore, there is high demand for new alternative methods able to differentiate Plasmodium species in a faster, cheaper and easier manner to execute. This review details the classical procedures and new perspectives of diagnostic methods for malaria non-falciparum differential detection and the possibilities of their application in different circumstances.
Collapse
Affiliation(s)
- Alba Marina Gimenez
- Department of Parasitology, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil
| | - Rodolfo F. Marques
- Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences, University of São Paulo, São Paulo, Brazil
| | - Matías Regiart
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, São Paulo, Brazil
| | - Daniel Youssef Bargieri
- Department of Parasitology, Institute of Biomedical Sciences, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
17
|
Performance and Application of Commercially Available Loop-Mediated Isothermal Amplification (LAMP) Kits in Malaria Endemic and Non-Endemic Settings. Diagnostics (Basel) 2021; 11:diagnostics11020336. [PMID: 33670618 PMCID: PMC7922894 DOI: 10.3390/diagnostics11020336] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 02/13/2021] [Accepted: 02/15/2021] [Indexed: 01/04/2023] Open
Abstract
Loop-mediated isothermal amplification (LAMP) is a sensitive molecular tool suitable for use as a near point-of-care test for the diagnosis of malaria. Recent meta-analyses have detailed high sensitivity and specificity of malaria LAMP when compared to microscopy, rapid diagnostic tests, and polymerase chain reaction in both endemic and non-endemic settings. Despite this, the use of malaria LAMP has primarily been limited to research settings to date. In this review, we aim to assess to what extent commercially available malaria LAMP kits have been applied in different settings, and to identify possible obstacles that may have hindered their use from being adopted further. In order to address this, we conducted a literature search in PubMed.gov using the search terms (((LAMP) OR (Loop-mediated isothermal amplification)) AND ((Malaria) OR (Plasmodium))). Focusing primarily on studies employing one of the commercially available kits, we then selected three key areas of LAMP application for further review: the performance and application of LAMP in malaria endemic settings including low transmission areas; LAMP for malaria screening during pregnancy; and malaria LAMP in returning travelers in non-endemic settings.
Collapse
|
18
|
Picot S, Cucherat M, Bienvenu AL. Systematic review and meta-analysis of diagnostic accuracy of loop-mediated isothermal amplification (LAMP) methods compared with microscopy, polymerase chain reaction and rapid diagnostic tests for malaria diagnosis. Int J Infect Dis 2020; 98:408-419. [PMID: 32659450 DOI: 10.1016/j.ijid.2020.07.009] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 07/01/2020] [Accepted: 07/05/2020] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Diagnosis is a challenging issue for eliminating malaria. Loop-mediated isothermal amplification (LAMP) could be an alternative to conventional methods. This study aimed to evaluate the diagnostic accuracy of LAMP for malaria compared with microscopy, polymerase chain reaction (PCR) and rapid diagnostic tests (RDTs). METHODS AND DESIGN MEDLINE, Web of Science and Scopus were searched from inception to 1 July 2019. Prospective and retrospective, randomised and non-randomised, mono-center and multi-center studies, including symptomatic or asymptomatic patients, that reported one LAMP method and one comparator (microscopy, RDT or PCR) were included. PROSPERO registration number: CRD42017075186. RESULTS Sixty-six studies published between 2006 and 2019 were included, leading to the analysis of 30,641 LAMP tests. The pooled sensitivity of LAMP remained between 96% and 98%, whichever the comparator. The pooled specificity of LAMP was around 95%, but was a little higher if the best PCR studies were considered. The AUC was found to be >0.98, whichever the subgroup of studies was considered. Diagnostic odds ratio (DOR) was found to be around 1000 for all subgroups, except for Plasmodium vivax. CONCLUSION This meta-analysis confirmed that the LAMP method is robust for diagnosing malaria, both in symptomatic and asymptomatic people. Thus, the impact of LAMP for controlling malaria is expected to be important.
Collapse
Affiliation(s)
- Stephane Picot
- Malaria Research Unit, SMITh, ICBMS UMR 5246 CNRS-INSA-CPE-Université de Lyon, Campus Lyon-Tech La Doua, 69622 Villeurbanne Cedex, France; Institut de Parasitologie et Mycologie Médicale, Hôpital de La Croix-Rousse, Hospices Civils de Lyon, Lyon, France
| | - Michel Cucherat
- Service de Pharmacotoxicologie, Hospices Civils de Lyon, Laboratoire de Biométrie et Biologie Évolutive, CNRS, UMR5558, Université Lyon 1, Lyon, France
| | - Anne-Lise Bienvenu
- Malaria Research Unit, SMITh, ICBMS UMR 5246 CNRS-INSA-CPE-Université de Lyon, Campus Lyon-Tech La Doua, 69622 Villeurbanne Cedex, France; Service Pharmacie, Groupement Hospitalier Nord, Hospices Civils de Lyon, France; Service d'Hématologie, Groupement Hospitalier Nord, Hospices Civils de Lyon, France.
| |
Collapse
|
19
|
Use of real-time multiplex PCR, malaria rapid diagnostic test and microscopy to investigate the prevalence of Plasmodium species among febrile hospital patients in Sierra Leone. Malar J 2020; 19:84. [PMID: 32085711 PMCID: PMC7035765 DOI: 10.1186/s12936-020-03163-2] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 02/13/2020] [Indexed: 11/24/2022] Open
Abstract
Background Malaria continues to affect over 200 million individuals every year, especially children in Africa. Rapid and sensitive detection and identification of Plasmodium parasites is crucial for treating patients and monitoring of control efforts. Compared to traditional diagnostic methods such as microscopy and rapid diagnostic tests (RDTs), DNA based methods, such as polymerase chain reaction (PCR) offer significantly higher sensitivity, definitive discrimination of Plasmodium species, and detection of mixed infections. While PCR is not currently optimized for routine diagnostics, its role in epidemiological studies is increasing as the world moves closer toward regional and eventually global malaria elimination. This study demonstrates the field use of a novel, ambient temperature-stabilized, multiplexed PCR assay in a small hospital setting in Sierra Leone. Methods Blood samples from 534 febrile individuals reporting to a hospital in Bo, Sierra Leone, were tested using three methods: a commercial RDT, microscopy, and a Multiplex Malaria Sample Ready (MMSR) PCR designed to detect a universal malaria marker and species-specific markers for Plasmodium falciparum and Plasmodium vivax. A separate PCR assay was used to identify species of Plasmodium in samples in which MMSR detected malaria, but was unable to identify the species. Results MMSR detected the presence of any malaria marker in 50.2% of all tested samples with P. falciparum identified in 48.7% of the samples. Plasmodium vivax was not detected. Testing of MMSR P. falciparum-negative/universal malaria-positive specimens with a panel of species-specific PCRs revealed the presence of Plasmodium malariae (n = 2) and Plasmodium ovale (n = 2). The commercial RDT detected P. falciparum in 24.6% of all samples while microscopy was able to detect malaria in 12.8% of tested specimens. Conclusions Wider application of PCR for detection of malaria parasites may help to fill gaps existing as a result of use of microscopy and RDTs. Due to its high sensitivity and specificity, species coverage, room temperature stability and relative low complexity, the MMSR assay may be useful for detection of malaria and epidemiological studies especially in low-resource settings.
Collapse
|
20
|
Development of a point-of-care test to detect hepatitis B virus DNA threshold relevant for treatment indication. ASIAN BIOMED 2019. [DOI: 10.1515/abm-2019-0021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Abstract
Background
Hepatitis B virus (HBV) has been the most prevalent blood-borne pathogen wherein utero transmission has still not been properly managed. Recent practice guidelines suggested that an antiviral drug should be administered to third-trimester pregnancies with significant viremia (>2 × 105 IU/mL).
Objectives
To develop a novel turbidity-based loop-mediated isothermal amplification (LAMP) coupled with heat treatment DNA extraction method that is a rapid, cost-effective, and feasible viral load assessment and could be applied to antenatal screening.
Methods
Primers and reagents were designed, turbidity-based platform and heat treatment method were added, and evaluated for optimal efficiency. Assay sensitivity was tested from serially diluted standard HBV DNA. Assay specificity was tested with six standard viral DNAs. Clinical samples were analyzed and the results were compared with those of quantitative polymerase chain reaction (qPCR) diagnostic records.
Results
The optimized condition was 60°C with no betaine, 1.4 mM deoxyribonucleotide triphosphates (dNTPs) and 6 mM of MgSO4 for 60 min. The assay accurately detected samples with standard HBV DNA at >2 × 105 IU/mL in both distilled water and spiked serum. Results can be interpreted within 31.48 ± 1.41 min in real-time turbidimeter. The amplification is exclusively specific to HBV, but not with the other six human-specific viruses. Moreover, the assay showed comparable performance within 95% confidence interval to the previously developed HBV LAMP toward clinical specimens.
Conclusions
This newly developed method was accurate, affordable, and flexible to further implementation to large-scale third-trimester pregnancy screening.
Collapse
|
21
|
Chahar M, Anvikar A, Dixit R, Valecha N. Evaluation of four novel isothermal amplification assays towards simple and rapid genotyping of chloroquine resistant Plasmodium falciparum. Exp Parasitol 2018; 190:1-9. [PMID: 29750967 DOI: 10.1016/j.exppara.2018.05.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2017] [Revised: 04/19/2018] [Accepted: 05/06/2018] [Indexed: 02/05/2023]
Abstract
Loop mediated isothermal amplification (LAMP) assay is sensitive, prompt, high throughput and field deployable technique for nucleic acid amplification under isothermal conditions. In this study, we have developed and optimized four different visualization methods of loop-mediated isothermal amplification (LAMP) assay to detect Pfcrt K76T mutants of P. falciparum and compared their important features for one-pot in-field applications. Even though all the four tested LAMP methods could successfully detect K76T mutants of P. falciparum, however considering the time, safety, sensitivity, cost and simplicity, the malachite green and HNB based methods were found more efficient. Among four different visual dyes uses to detect LAMP products accurately, hydroxynaphthol blue and malachite green could produce long stable color change and brightness in a close tube-based approach to prevent cross-contamination risk. Our results indicated that the LAMP offers an interesting novel and convenient best method for the rapid, sensitive, cost-effective, and fairly user friendly tool for detection of K76T mutants of P. falciparum and therefore presents an alternative to PCR-based assays. Based on our comparative analysis, better field based LAMP visualization method can be chosen easily for the monitoring of other important drug targets (Kelch13 propeller region).
Collapse
Affiliation(s)
- Madhvi Chahar
- Division of Epidemiology & Clinical Research, National Institute of Malaria Research, Sector-8 Dwarka, New Delhi, India.
| | - Anup Anvikar
- Division of Epidemiology & Clinical Research, National Institute of Malaria Research, Sector-8 Dwarka, New Delhi, India
| | - Rajnikant Dixit
- Division of Epidemiology & Clinical Research, National Institute of Malaria Research, Sector-8 Dwarka, New Delhi, India
| | - Neena Valecha
- Division of Epidemiology & Clinical Research, National Institute of Malaria Research, Sector-8 Dwarka, New Delhi, India
| |
Collapse
|
22
|
Ponce C, Kaczorowski F, Perpoint T, Miailhes P, Sigal A, Javouhey E, Gillet Y, Jacquin L, Douplat M, Tazarourte K, Potinet V, Simon B, Lavoignat A, Bonnot G, Sow F, Bienvenu AL, Picot S. Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening patients with imported malaria in a non-endemic setting. ACTA ACUST UNITED AC 2017; 24:53. [PMID: 29251261 PMCID: PMC5734902 DOI: 10.1051/parasite/2017054] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Accepted: 11/29/2017] [Indexed: 11/14/2022]
Abstract
BACKGROUND Sensitive and easy-to-perform methods for the diagnosis of malaria are not yet available. Improving the limit of detection and following the requirements for certification are issues to be addressed in both endemic and non-endemic settings. The aim of this study was to test whether loop-mediated isothermal amplification of DNA (LAMP) may be an alternative to microscopy or real-time PCR for the screening of imported malaria cases in non-endemic area. RESULTS 310 blood samples associated with 829 suspected cases of imported malaria were tested during a one year period. Microscopy (thin and thick stained blood slides, reference standard) was used for the diagnosis. Real-time PCR was used as a standard of truth, and LAMP (Meridian Malaria Plus) was used as an index test in a prospective study conducted following the Standards for Reporting Diagnosis Accuracy Studies. In the 83 positive samples, species identification was P. falciparum (n = 66), P. ovale (n = 9), P. vivax (n = 3) P. malariae (n = 3) and 2 co-infections with P. falciparum + P.malariae. Using LAMP methods, 93 samples gave positive results, including 4 false-positives. Sensitivity, specificity, positive predictive value and negative predictive value for LAMP tests were 100%, 98.13%, 95.51%, and 100% compared to PCR. CONCLUSION High negative predictive value, and limit of detection suggest that LAMP can be used for screening of imported malaria cases in non-endemic countries when expert microscopists are not immediately available. However, the rare occurrence of non-valid results and the need for species identification and quantification of positive samples preclude the use of LAMP as a single reference method.
Collapse
Affiliation(s)
- Camille Ponce
- Institute of Parasitology and Medical Mycology, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France
| | - Flora Kaczorowski
- Institute of Parasitology and Medical Mycology, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France
| | - Thomas Perpoint
- Service des Maladies Infectieuses et Tropicales, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France
| | - Patrick Miailhes
- Service des Maladies Infectieuses et Tropicales, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France
| | - Alain Sigal
- Service d'accueil des Urgences, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France
| | - Etienne Javouhey
- Service d'accueil des Urgences Pédiatriques, Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, 69677 Bron, France
| | - Yves Gillet
- Service d'accueil des Urgences Pédiatriques, Hôpital Femme-Mère-Enfant, Hospices Civils de Lyon, 69677 Bron, France
| | - Laurent Jacquin
- Service d'accueil des urgences, Hôpital Edouard Herriot, Hospices Civils de Lyon, 69003 Lyon, France
| | - Marion Douplat
- Service d'accueil des urgences, Hôpital Lyon Sud, Hospices Civils de Lyon, Hôpital Lyon Sud, 69310 Pierre-Bénite, France
| | - Karim Tazarourte
- Service des urgences/SAMU 69, Hospices Civils de Lyon, Lyon, 69003, France - Univ. Lyon, Université Claude Bernard Lyon 1, HESPER EA 7425, 69008 Lyon, France
| | - Véronique Potinet
- Service d'accueil des urgences, Hôpital Lyon Sud, Hospices Civils de Lyon, Hôpital Lyon Sud, 69310 Pierre-Bénite, France
| | - Bruno Simon
- Institute of Parasitology and Medical Mycology, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France
| | - Adeline Lavoignat
- Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France
| | - Guillaume Bonnot
- Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France
| | - Fatimata Sow
- Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France
| | - Anne-Lise Bienvenu
- Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France - Laboratoire d'Hématologie, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France
| | - Stéphane Picot
- Institute of Parasitology and Medical Mycology, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, 69004 Lyon, France - Malaria Research Unit, SMITh, ICBMS, UMR 5246 CNRS-INSA-CPE-University Lyon1, 69100 Villeurbanne, France
| |
Collapse
|
23
|
Besuschio SA, Llano Murcia M, Benatar AF, Monnerat S, Cruz I, Picado A, Curto MDLÁ, Kubota Y, Wehrendt DP, Pavia P, Mori Y, Puerta C, Ndung'u JM, Schijman AG. Analytical sensitivity and specificity of a loop-mediated isothermal amplification (LAMP) kit prototype for detection of Trypanosoma cruzi DNA in human blood samples. PLoS Negl Trop Dis 2017; 11:e0005779. [PMID: 28727723 PMCID: PMC5544240 DOI: 10.1371/journal.pntd.0005779] [Citation(s) in RCA: 73] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Revised: 08/04/2017] [Accepted: 07/05/2017] [Indexed: 02/02/2023] Open
Abstract
This study aimed to assess analytical parameters of a prototype LAMP kit that was designed for detection of Trypanosoma cruzi DNA in human blood. The prototype is based on the amplification of the highly repetitive satellite sequence of T.cruzi in microtubes containing dried reagents on the inside of the caps. The reaction is carried out at 65°C during 40 minutes. Calcein allows direct detection of amplified products with the naked eye. Inclusivity and selectivity were tested in purified DNA from Trypanosoma cruzi stocks belonging to the six discrete typing units (DTUs), in DNA from other protozoan parasites and in human DNA. Analytical sensitivity was estimated in serial dilutions of DNA samples from Sylvio X10 (Tc I) and CL Brener (Tc VI) stocks, as well as from EDTA-treated or heparinized blood samples spiked with known amounts of cultured epimastigotes (CL Brener). LAMP sensitivity was compared after DNA extraction using commercial fiberglass columns or after “Boil & Spin” rapid preparation. Moreover, the same DNA and EDTA-blood spiked samples were subjected to standardized qPCR based on the satellite DNA sequence for comparative purposes. A panel of peripheral blood specimens belonging to Chagas disease patients, including acute, congenital, chronic and reactivated cases (N = 23), as well as seronegative controls (N = 10) were evaluated by LAMP in comparison to qPCR. LAMP was able to amplify DNAs from T. cruzi stocks representative of the six DTUs, whereas it did not amplify DNAs from Leishmania sp, T. brucei sp, T. rangeli KPN+ and KPN-, P. falciparum and non-infected human DNA. Analytical sensitivity was 1x10-2 fg/μL of both CL Brener and Sylvio X10 DNAs, whereas qPCR detected up to 1x 10−1 fg/μL of CL Brener DNA and 1 fg/μl of Sylvio X10 DNA. LAMP detected 1x10-2 parasite equivalents/mL in spiked EDTA blood and 1x10-1 par.eq/mL in spiked heparinized blood using fiberglass columns for DNA extraction, whereas qPCR detected 1x10-2 par.eq./mL in EDTA blood. Boil & Spin extraction allowed detection of 1x10-2 par.eq /mL in spiked EDTA blood and 1 par.eq/ml in heparinized blood. LAMP was able to detect T.cruzi infection in peripheral blood samples collected from well-characterised seropositive patients, including acute, congenital, chronic and reactivated Chagas disease. To our knowledge, this is the first report of a prototype LAMP kit with appropriate analytical sensitivity for diagnosis of Chagas disease patients, and potentially useful for monitoring treatment response. Trypanosoma cruzi, a parasite transmitted to humans from hematophagous insects, causes Chagas Disease, a Neglected Tropical Disease with public health impact, affecting 7 million people in Latin America. Although mainly related to low income populations inhabiting rural environments, migrations have conveyed Chagas Disease to urban areas of endemic and non-endemic countries. It often presents non-specific symptoms, and direct, low cost microscopy-based diagnosis only detects acute infections, missing a high proportion of cases. Serology is the “gold standard” diagnostic technique for chronic stages and needs the concordance of at least two different assays to confirm infection. In this context, we aimed to evaluate the analytical sensitivity and specificity of a prototype kit based on a novel and rapid molecular biology reaction, named Loop mediated isothermal amplification (LAMP), using standardized Real Time PCR as a comparator. To our knowledge, this is the first LAMP prototype kit with an analytical performance appropriate for human diagnosis of Chagas disease and potentially useful for monitoring treatment response. Its simple handling using basic laboratory devices will enable point-of-care diagnosis and screening for congenital infection at birth as well as early detection of acute infections due to oral contamination.
Collapse
Affiliation(s)
- Susana A. Besuschio
- Laboratorio de Biología Molecular de la Enfermedad de Chagas, Instituto de Investigaciones en Ingeniería Genética y Biología Molecular – Consejo Nacional de Investigaciones Científicas y Tecnológicas (INGEBI-CONICET), Buenos Aires Argentina
| | - Mónica Llano Murcia
- Laboratorio de Parasitología Molecular, Facultad de Ciencias -Pontificia Universidad Javeriana, Bogotá, Colombia
| | - Alejandro F. Benatar
- Laboratorio de Biología Molecular de la Enfermedad de Chagas, Instituto de Investigaciones en Ingeniería Genética y Biología Molecular – Consejo Nacional de Investigaciones Científicas y Tecnológicas (INGEBI-CONICET), Buenos Aires Argentina
| | | | - Israel Cruz
- Foundation for Innovative New Diagnostics, Geneva, Switzerland
| | - Albert Picado
- Foundation for Innovative New Diagnostics, Geneva, Switzerland
| | - María de los Ángeles Curto
- Laboratorio de Biología Molecular de la Enfermedad de Chagas, Instituto de Investigaciones en Ingeniería Genética y Biología Molecular – Consejo Nacional de Investigaciones Científicas y Tecnológicas (INGEBI-CONICET), Buenos Aires Argentina
| | | | - Diana P. Wehrendt
- Laboratorio de Biología Molecular de la Enfermedad de Chagas, Instituto de Investigaciones en Ingeniería Genética y Biología Molecular – Consejo Nacional de Investigaciones Científicas y Tecnológicas (INGEBI-CONICET), Buenos Aires Argentina
| | - Paula Pavia
- Laboratorio de Parasitología Molecular, Facultad de Ciencias -Pontificia Universidad Javeriana, Bogotá, Colombia
| | | | - Concepción Puerta
- Laboratorio de Parasitología Molecular, Facultad de Ciencias -Pontificia Universidad Javeriana, Bogotá, Colombia
| | | | - Alejandro G. Schijman
- Laboratorio de Biología Molecular de la Enfermedad de Chagas, Instituto de Investigaciones en Ingeniería Genética y Biología Molecular – Consejo Nacional de Investigaciones Científicas y Tecnológicas (INGEBI-CONICET), Buenos Aires Argentina
- * E-mail:
| |
Collapse
|