1
|
Khanda M, Seal P, Mohan AJ, Arya N, Boda SK. Antimicrobial peptides and their application to combat implant-associated infections - opportunities and challenges. NANOSCALE 2025; 17:10462-10484. [PMID: 40227869 DOI: 10.1039/d5nr00953g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/16/2025]
Abstract
Despite minimally invasive surgeries and advancements in aseptic techniques, implant-associated infections are a significant complication in post-surgical implantation of medical devices. The standard practice of systemic antibiotic administration is often ineffective due to the development of bacterial antibiotic resistance, poor antibiotic penetration into biofilms, and low antibiotic bioavailability at the infected site. Infected implants are typically salvaged by tissue resection and antibacterial reinforcements during revision surgery. Towards this end, antimicrobial peptides (AMPs) have emerged as a promising alternative to traditional antibiotics to combat infections. Herein, a comprehensive overview of antimicrobial peptides, their structure and function, comparison with conventional antibiotics, antimicrobial properties, mechanisms of action of AMPs, and bacterial resistance to AMPs in relation to antibiotics are discussed. Furthermore, stimuli-responsive AMP delivery and contact killing via AMP coatings on implant surfaces are deliberated. We discuss various methods of AMP immobilization and coatings on implant materials through physico-chemical coating strategies. The review also addresses the clinical status and current limitations of AMP coatings such as proteolytic instability and potential cytotoxicity. Finally, we conclude with future directions to develop small, effective AMP mimetics and encapsulation of AMPs within nanocarriers to improve antimicrobial properties and design-controlled release systems for sustained antimicrobial activity.
Collapse
Affiliation(s)
- Milan Khanda
- Department of Bioscience and Biomedical Engineering, Indian Institute of Technology Indore, Khandwa Road, Simrol, Indore, Madhya Pradesh, 453552, India.
| | - Pallabi Seal
- Department of Bioscience and Biomedical Engineering, Indian Institute of Technology Indore, Khandwa Road, Simrol, Indore, Madhya Pradesh, 453552, India.
| | - Arya J Mohan
- Department of Translational Medicine, All India Institute of Medical Sciences Bhopal, Bhopal, Madhya Pradesh, 462020, India
| | - Neha Arya
- Department of Translational Medicine, All India Institute of Medical Sciences Bhopal, Bhopal, Madhya Pradesh, 462020, India
| | - Sunil Kumar Boda
- Department of Bioscience and Biomedical Engineering, Indian Institute of Technology Indore, Khandwa Road, Simrol, Indore, Madhya Pradesh, 453552, India.
- Department of Medical Science and Technology, Indian Institute of Technology Madras, Chennai, Tamil Nadu, 600036, India
| |
Collapse
|
2
|
Dini C, Borges MHR, Malheiros SS, Piazza RD, van den Beucken JJJP, de Avila ED, Souza JGS, Barão VAR. Progress in Designing Therapeutic Antimicrobial Hydrogels Targeting Implant-associated Infections: Paving the Way for a Sustainable Platform Applied to Biomedical Devices. Adv Healthc Mater 2025; 14:e2402926. [PMID: 39440583 DOI: 10.1002/adhm.202402926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 09/19/2024] [Indexed: 10/25/2024]
Abstract
Implantable biomedical devices have found widespread use in restoring lost functions or structures within the human body, but they face a significant challenge from microbial-related infections, which often lead to implant failure. In this context, antimicrobial hydrogels emerge as a promising strategy for treating implant-associated infections owing to their tunable physicochemical properties. However, the literature lacks a comprehensive analysis of antimicrobial hydrogels, encompassing their development, mechanisms, and effect on implant-associated infections, mainly in light of existing in vitro, in vivo, and clinical evidence. Thus, this review addresses the strategies employed by existing studies to tailor hydrogel properties to meet the specific needs of each application. Furthermore, this comprehensive review critically appraises the development of antimicrobial hydrogels, with a particular focus on solving infections related to metallic orthopedic or dental implants. Then, preclinical and clinical studies centering on providing quantitative microbiological results associated with the application of antimicrobial hydrogels are systematically summarized. Overall, antimicrobial hydrogels benefit from the tunable properties of polymers and hold promise as an effective strategy for the local treatment of implant-associated infections. However, future clinical investigations, grounded on robust evidence from in vitro and preclinical studies, are required to explore and validate new antimicrobial hydrogels for clinical use.
Collapse
Affiliation(s)
- Caroline Dini
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo, 13414-903, Brazil
| | - Maria Helena Rossy Borges
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo, 13414-903, Brazil
| | - Samuel Santana Malheiros
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo, 13414-903, Brazil
| | - Rodolfo Debone Piazza
- Physical Chemistry Department, Institute of Chemistry, São Paulo State University (UNESP), Araraquara, São Paulo, 14800-900, Brazil
| | | | - Erica Dorigatti de Avila
- Department of Dental Materials and Prosthodontics, School of Dentistry at Araçatuba, São Paulo State University (UNESP), Araçatuba, São Paulo, 16015-050, Brazil
| | - João Gabriel S Souza
- Dental Research Division, Guarulhos University (UNG), Guarulhos, São Paulo, 07023-070, Brazil
| | - Valentim A R Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo, 13414-903, Brazil
| |
Collapse
|
3
|
Taha M, AlDuwaisan A, Daneshmand M, Ibrahim MM, Bourget-Murray J, Grammatopoulos G, Garceau S, Abdelbary H. Mapping Staphylococcus aureus at Early and Late Stages of Infection in a Clinically Representative Hip Prosthetic Joint Infection Rat Model. Microorganisms 2024; 12:1895. [PMID: 39338569 PMCID: PMC11433939 DOI: 10.3390/microorganisms12091895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 08/27/2024] [Accepted: 08/29/2024] [Indexed: 09/30/2024] Open
Abstract
Prosthetic joint infection (PJI) continues to be a devastating complication following total joint replacement surgeries where Staphylococcus aureus is the main offending organism. To improve our understanding of the disease pathogenesis, a histological analysis of infected peri-implant tissue in a hip PJI rat model was utilized to assess S. aureus spread and tissue reaction at early and late stages of infection. Sprague-Dawley rats were used and received a left cemented hip hemiarthroplasty using a 3D-printed titanium femoral stem. The rats received an intra-articular injection of S. aureus Xen36. These infected rats were sacrificed either at 3 days post-infection (early-stage infection) or at 13-days post-infection (late-stage infection). The femoral and acetabular tissues of all animals were harvested at euthanasia. Histological analysis for the harvested tissue was performed using immunohistochemistry, hematoxylin and eosin, as well as Masson's trichrome stains. Histological examination revealed significant quantitative and qualitative differences in peri-implant tissue response to infection at early and late stages. This hip PJI rat model identified clear histologic differences between early and late stages of S. aureus infection and how quickly bacterial infiltration could occur. These findings can provide insight into why certain surgical strategies like debridement and antibiotics may be associated with high failure rates.
Collapse
Affiliation(s)
- Mariam Taha
- Chronic Disease Program, The Ottawa Hospital Research Institute, Ottawa, ON K1H 8L6, Canada
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON K1H 8L6, Canada
| | - Abdullah AlDuwaisan
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON K1H 8L6, Canada
- Division of Orthopaedic Surgery, Faculty of Medicine, Kuwait University, Jabriya, Kuwait
| | - Manijeh Daneshmand
- Department of Pathology and Laboratory Medicine, University of Ottawa, Ottawa, ON K1H 8M5, Canada
| | - Mazen M Ibrahim
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON K1H 8L6, Canada
| | | | | | - Simon Garceau
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON K1H 8L6, Canada
| | - Hesham Abdelbary
- Chronic Disease Program, The Ottawa Hospital Research Institute, Ottawa, ON K1H 8L6, Canada
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON K1H 8L6, Canada
| |
Collapse
|
4
|
Li C, Gao D, Li C, Cheng G, Zhang L. Fighting against biofilm: The antifouling and antimicrobial material. Biointerphases 2024; 19:040802. [PMID: 39023091 DOI: 10.1116/6.0003695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Accepted: 06/07/2024] [Indexed: 07/20/2024] Open
Abstract
Biofilms are groups of microorganisms protected by self-secreted extracellular substances. Biofilm formation on the surface of biomaterial or engineering materials becomes a severe challenge. It has caused significant health, environmental, and societal concerns. It is believed that biofilms lead to life-threatening infection, medical implant failure, foodborne disease, and marine biofouling. To address these issues, tremendous effort has been made to inhibit biofilm formation on materials. Biofilms are extremely difficult to treat once formed, so designing material and coating bearing functional groups that are capable of resisting biofilm formation has attracted increasing attention for the last two decades. Many types of antibiofilm strategies have been designed to target different stages of biofilm formation. Development of the antibiofilm material can be classified into antifouling material, antimicrobial material, fouling release material, and integrated antifouling/antimicrobial material. This review summarizes relevant research utilizing these four approaches and comments on their antibiofilm properties. The feature of each method was compared to reveal the research trend. Antibiofilm strategies in fundamental research and industrial applications were summarized.
Collapse
Affiliation(s)
- Chao Li
- School of Engineering, Westlake University, Hangzhou, Zhejiang 310030, China
- Department of Pharmaceutical Sciences, State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian, Liaoning 116023, China
| | - Dongdong Gao
- School of Engineering, Westlake University, Hangzhou, Zhejiang 310030, China
- Department of Pharmaceutical Sciences, State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian, Liaoning 116023, China
| | - Chunmei Li
- Tsinglan School, Songshan Lake, Dongguan 523000, China
| | - Gang Cheng
- School of Engineering, Westlake University, Hangzhou, Zhejiang 310030, China
| | - Lijun Zhang
- Liaoning Provincial Key Laboratory of Cornea and Ocular Surface Diseases, Liaoning Provincial Optometry Technology Engineering Research Center, The Third People's Hospital of Dalian, Dalian, Liaoning 116033, China
| |
Collapse
|
5
|
Mikziński P, Kraus K, Widelski J, Paluch E. Modern Microbiological Methods to Detect Biofilm Formation in Orthopedy and Suggestions for Antibiotic Therapy, with Particular Emphasis on Prosthetic Joint Infection (PJI). Microorganisms 2024; 12:1198. [PMID: 38930580 PMCID: PMC11205407 DOI: 10.3390/microorganisms12061198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2024] [Revised: 06/05/2024] [Accepted: 06/11/2024] [Indexed: 06/28/2024] Open
Abstract
Biofilm formation is a serious problem that relatively often causes complications in orthopedic surgery. Biofilm-forming pathogens invade implanted foreign bodies and surrounding tissues. Such a condition, if not limited at the appropriate time, often requires reoperation. This can be partially prevented by selecting an appropriate prosthesis material that prevents the development of biofilm. There are many modern techniques available to detect the formed biofilm. By applying them we can identify and visualize biofilm-forming microorganisms. The most common etiological factors associated with biofilms in orthopedics are: Staphylococcus aureus, coagulase-negative Staphylococci (CoNS), and Enterococcus spp., whereas Gram-negative bacilli and Candida spp. also deserve attention. It seems crucial, for therapeutic success, to eradicate the microorganisms able to form biofilm after the implantation of endoprostheses. Planning the effective targeted antimicrobial treatment of postoperative infections requires accurate identification of the microorganism responsible for the complications of the procedure. The modern microbiological testing techniques described in this article show the diagnostic options that can be followed to enable the implementation of effective treatment.
Collapse
Affiliation(s)
- Paweł Mikziński
- Faculty of Medicine, Wroclaw Medical University, Wyb. Pasteura 1, 50-376 Wroclaw, Poland; (P.M.); (K.K.)
| | - Karolina Kraus
- Faculty of Medicine, Wroclaw Medical University, Wyb. Pasteura 1, 50-376 Wroclaw, Poland; (P.M.); (K.K.)
| | - Jarosław Widelski
- Department of Pharmacognosy with Medicinal Plants Garden, Lublin Medical University, 20-093 Lublin, Poland;
| | - Emil Paluch
- Department of Microbiology, Faculty of Medicine, Wroclaw Medical University, Tytusa Chalubinskiego 4, 50-376 Wroclaw, Poland
| |
Collapse
|
6
|
Corona PS, Vargas Meouchi EA, García Hernández JM, Soriano RF, Crespo-Fresno A, Issa-Benítez D, Mudaris MA, Soldado F. Single-stage transcutaneous osseointegrated prosthesis for above-knee amputations including an antibiotic-loaded hydrogel. Preliminary results of a new surgical protocol. Injury 2024; 55:111424. [PMID: 38402710 DOI: 10.1016/j.injury.2024.111424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 12/08/2023] [Accepted: 02/10/2024] [Indexed: 02/27/2024]
Abstract
INTRODUCTION Patients with above-knee amputations (AKA) are normally treated with the traditional socket-mounted prosthesis (SMP), which is associated with a high incidence of problems. Osseointegration has been proposed as a promising option for avoiding many common SMP drawbacks. Several concerns have arisen regarding amputee osseointegration, however, mainly with respect to infection. We report on the safety of a single-stage osseointegration protocol using an antibiotic-loaded hydrogel to coat the intramedullary implant. MATERIALS AND METHODS We retrospectively reviewed all AKA cases treated at our center between January 2019 and April 2022, in which a transcutaneous osseointegrated implant was used in a single-stage strategy, together with a rapid-resorbable hydrogel loaded with vancomycin and gentamicin. The specific protocol used, infection rate, implant osseointegration rate and implant survivorship were determined after a minimum follow-up of 12 months. RESULTS Eleven osseointegration cases were included in the study, with an average of 16 years post-amputation (range: 3-35 years). After a median follow-up of 24 months (range 12-49 months) no patient had suffered any implant-related infection. Osseointegration of the implant had been achieved in all cases. The mid-term survivorship of the implant in our series was 100 % at the end of follow-up. Radiographs of all cases showed no loosening of the implant. Further, 91 % of the series patients were able to walk without restrictions after the rehabilitation process. CONCLUSIONS The single-stage osseointegration protocol for AKA, using a rapid-resorbable hydrogel loaded with vancomycin and gentamicin, yields low rates of implant-related deep infection. This protocol consistently delivers high rates of radiological osseointegration, with no hydrogel-associated complications.
Collapse
Affiliation(s)
- Pablo S Corona
- Septic and Reconstructive Surgery Unit (UCSO), Orthopaedic Surgery Department, Vall d'Hebrón University Hospital, Barcelona, Spain; Orthopaedic Surgery Department, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain; Musculoskeletal Tissue Engineering Group, Vall d'Hebrón Research Institute (VHIR), Barcelona, Spain. Universitat Autònoma de Barcelona, Spain
| | - Enrique A Vargas Meouchi
- Orthopaedic Surgery Department, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain; Musculoskeletal Tissue Engineering Group, Vall d'Hebrón Research Institute (VHIR), Barcelona, Spain. Universitat Autònoma de Barcelona, Spain.
| | | | - Rosa Fraile Soriano
- Septic and Reconstructive Surgery Unit (UCSO), Orthopaedic Surgery Department, Vall d'Hebrón University Hospital, Barcelona, Spain; Surgical nurse team, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Almudena Crespo-Fresno
- Amputee Unit, Physical Medicine and Rehabilitation Department, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Daniela Issa-Benítez
- Amputee Unit, Physical Medicine and Rehabilitation Department, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Munjed Al Mudaris
- Department of Orthopaedic Surgery, Macquarie University Hospital, Macquarie University, Sydney, Australia
| | - Francisco Soldado
- Pediatric Orthopedic Surgery Department, Vall d'Hebron University Hospital, Barcelona, Spain Universitat Autònoma de Barcelona, Spain; Pediatric Hand Surgery and Microsurgery Unit. Barcelona University Children´s Hospital HM Nens, Barcelona, Spain
| |
Collapse
|
7
|
Fiore M, Sambri A, Morante L, Bortoli M, Parisi SC, Panzavolta F, Alesi D, Neri E, Neri MP, Tedeschi S, Zamparini E, Cevolani L, Donati DM, Viale P, Campanacci DA, Zaffagnini S, De Paolis M. Silver-Coated Distal Femur Megaprosthesis in Chronic Infections with Severe Bone Loss: A Multicentre Case Series. J Clin Med 2023; 12:6679. [PMID: 37892817 PMCID: PMC10607434 DOI: 10.3390/jcm12206679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 10/20/2023] [Accepted: 10/20/2023] [Indexed: 10/29/2023] Open
Abstract
Periprosthetic joint infections (PJI) and fracture-related infections (FRI) of the distal femur (DF) may result in massive bone defects. Treatment options include articulated silver-coated (SC) megaprosthesis (MP) in the context of a two-stage protocol. However, there is limited evidence in the literature on this topic. A retrospective review of the prospectively maintained databases of three Institutions was performed. Forty-five patients were included. The mean follow-up time was 43 ± 17.1 months. Eight (17.8%) patients had a recurrent infection. The estimated recurrence-free survival rate was 91.1% (93.5% PJI vs. 85.7% FRI) 2 years following MP implantation, and 75.7% (83.2% PJI vs. 64.3% FRI; p = 0.253) after 5 years. No statistically relevant difference was found according to the initial diagnosis (PJI vs. FRI). Among possible risk factors, only resection length was found to significantly worsen the outcomes in terms of infection control (p = 0.031). A total of eight complications not related to infection were found after reimplantation, but only five of them required further surgery. Above-the-knee amputation was performed in two cases (4.4%), both for reinfection. Articulated DF SC MP in a two-stage protocol is a safe and effective treatment for chronic knee infection with severe bone loss.
Collapse
Affiliation(s)
- Michele Fiore
- Department of Medical and Surgical Sciences, Alma Mater Studiorum University of Bologna, 40138 Bologna, Italy; (M.F.); (S.T.)
| | - Andrea Sambri
- Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; (L.M.); (F.P.); (M.D.P.)
| | - Lorenzo Morante
- Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; (L.M.); (F.P.); (M.D.P.)
| | - Marta Bortoli
- Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; (L.M.); (F.P.); (M.D.P.)
| | - Stefania Claudia Parisi
- Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; (L.M.); (F.P.); (M.D.P.)
| | - Francesco Panzavolta
- Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; (L.M.); (F.P.); (M.D.P.)
| | - Domenico Alesi
- Second Orthopaedic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (D.A.); (S.Z.)
| | - Elisabetta Neri
- Orthopaedic Oncology Unit, Azienda Ospedaliera Universitaria Careggi, 50134 Firenze, Italy (D.A.C.)
| | - Maria Pia Neri
- Second Orthopaedic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (D.A.); (S.Z.)
| | - Sara Tedeschi
- Department of Medical and Surgical Sciences, Alma Mater Studiorum University of Bologna, 40138 Bologna, Italy; (M.F.); (S.T.)
- Infectious Disease Unit, Department for Integrated Infectious Risk Management, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Eleonora Zamparini
- Infectious Disease Unit, Department for Integrated Infectious Risk Management, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Luca Cevolani
- Third Orthopaedic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy (D.M.D.)
| | - Davide Maria Donati
- Third Orthopaedic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy (D.M.D.)
| | - Pierluigi Viale
- Department of Medical and Surgical Sciences, Alma Mater Studiorum University of Bologna, 40138 Bologna, Italy; (M.F.); (S.T.)
- Infectious Disease Unit, Department for Integrated Infectious Risk Management, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | | | - Stefano Zaffagnini
- Second Orthopaedic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (D.A.); (S.Z.)
| | - Massimiliano De Paolis
- Orthopaedics and Traumatology Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; (L.M.); (F.P.); (M.D.P.)
| |
Collapse
|
8
|
Zareei A, Kasi V, Thornton A, Rivera UH, Sawale M, Maruthamuthu MK, He Z, Nguyen J, Wang H, Mishra DK, Rahimi R. Non-destructive processing of silver containing glass ceramic antibacterial coating on polymeric surgical mesh surfaces. NANOSCALE 2023; 15:11209-11221. [PMID: 37345366 PMCID: PMC10552273 DOI: 10.1039/d3nr01317k] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/23/2023]
Abstract
Surgical meshes composed of bioinert polymers such as polypropylene are widely used in millions of hernia repair procedures to prevent the recurrence of organ protrusion from the damaged abdominal wall. However, post-operative mesh infection remains a significant complication, elevating hernia recurrence risks from 3.6% to 10%, depending on the procedure type. While attempts have been made to mitigate these infection-related complications by using antibiotic coatings, the rise in antibiotic-resistant bacterial strains threatens their effectiveness. Bioactive glass-ceramics featuring noble metals, notably silver nanoparticles (AgNPs), have recently gained traction for their wide antibacterial properties and biocompatibility. Yet, conventional methods of synthesizing and coating of such materials often require high temperatures, thus making them impractical to be implemented on temperature-sensitive polymeric substrates. To circumvent this challenge, a unique approach has been explored to deposit these functional compounds onto temperature-sensitive polypropylene mesh (PP-M) surfaces. This approach is based on the recent advancements in cold atmospheric plasma (CAP) assisted deposition of SiO2 thin films and laser surface treatment (LST), enabling the selective heating and formation of functional glass-ceramic compounds under atmospheric conditions. A systematic study was conducted to identify optimal LST conditions that resulted in the effective formation of a bioactive glass-ceramic structure without significantly altering the chemical and mechanical properties of the underlying PP-M (less than 1% change compared to the original properties). The developed coating with optimized processing conditions demonstrated high biocompatibility and persistent antibacterial properties (>7 days) against both Gram-positive and Gram-negative bacteria. The developed process is expected to provide a new stepping stone towards depositing a wide range of functional bioceramic coatings onto different implant surfaces, thereby decreasing their risk of infection and associated complications.
Collapse
Affiliation(s)
- Amin Zareei
- School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA.
- Birck Nanotechnology Canter, Purdue University, West Lafayette, IN 47907, USA
| | - Venkat Kasi
- School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA.
- Birck Nanotechnology Canter, Purdue University, West Lafayette, IN 47907, USA
| | - Allison Thornton
- School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA.
- Birck Nanotechnology Canter, Purdue University, West Lafayette, IN 47907, USA
| | - Ulisses Heredia Rivera
- School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA.
- Birck Nanotechnology Canter, Purdue University, West Lafayette, IN 47907, USA
| | - Manoj Sawale
- Department of Food Science, Purdue University, West Lafayette, IN 47907, USA
| | - Murali Kannan Maruthamuthu
- Division of Pharmacoengineering and Molecular Pharmaceutics, Eshelman School of Pharmacy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | - Zihao He
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Juliane Nguyen
- Division of Pharmacoengineering and Molecular Pharmaceutics, Eshelman School of Pharmacy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | - Haiyan Wang
- School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA.
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
| | - Dharmendra K Mishra
- Department of Food Science, Purdue University, West Lafayette, IN 47907, USA
| | - Rahim Rahimi
- School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA.
- Birck Nanotechnology Canter, Purdue University, West Lafayette, IN 47907, USA
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|
9
|
Morimoto T, Tsukamoto M, Aita K, Fujita N, Mawatari M. First clinical experience with posterior lumbar interbody fusion using a thermal-sprayed silver-containing hydroxyapatite-coated cage. J Orthop Surg Res 2023; 18:392. [PMID: 37254205 DOI: 10.1186/s13018-023-03882-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 05/26/2023] [Indexed: 06/01/2023] Open
Abstract
BACKGROUND To investigate the possibility of silver (Ag)-induced adverse events and the degree of bone fusion in posterior lumbar interbody fusion surgery using an Ag-containing hydroxyapatite (HA) lumbar interbody cage. METHODS An Ag-HA cage consisting of highly osteoconductive HA interfused with Ag was developed, and we applied it clinically at three university-affiliated hospitals from April 2020 to December 2020. During the 12-month postoperative observation period, Ag-related adverse events, neuropathy, and postoperative complications were investigated as indicators of safety, while clinical improvement and the fusion status were investigated as indicators of efficacy. Clinical improvement was defined as improvement beyond the minimum clinically important difference (MCID) in the numerical rating scale (NRS; 1.6) for low back and lower limb pain and the Oswestry Disability Index (ODI; 12.8). RESULTS We performed lumbar interbody fusion using an Ag-HA cage for 48 patients (female, n = 25; mean age, 67.5 years). The mean preoperative NRS was 6.4 (standard deviation, 1.9), while the mean preoperative ODI was 44 [12]. No adverse effects (i.e., argyria) were identified during the 12-month observation period. Surgical site infection occurred in one case, although the implant was preserved via immediate debridement. In total, 39 (81%) participants showed clinical improvement beyond MCID for both NRS and ODI. Bone fusion was achieved at 45 levels (88%) at 6 months and 48 levels (91%) at 12 months postoperatively. CONCLUSIONS The results of this study suggest that Ag-HA cages can be safely used in spinal fusion procedures and have the potential to prevent postoperative infections, prevent deterioration of the quality of life, and result in favorable outcomes. Larger-scale and longer-term follow-up studies will be required to corroborate these conclusions. Trial registration UMIN 000039964 (date: April 01, 2020).
Collapse
Affiliation(s)
- Tadatsugu Morimoto
- Department of Orthopedic Surgery, Faculty of Medicine, Saga University, Nabeshima 5-1-1, Saga, Japan.
| | - Masatsugu Tsukamoto
- Department of Orthopedic Surgery, Faculty of Medicine, Saga University, Nabeshima 5-1-1, Saga, Japan
| | - Katsuhiro Aita
- Department of Orthopedic Surgery, Saga Memorial Hospital, Saga, Japan
| | - Nobuyuki Fujita
- Department of Orthopedic Surgery, Faculty of Medicine, Fujita Health University, Aichi, Japan
| | - Masaaki Mawatari
- Department of Orthopedic Surgery, Faculty of Medicine, Saga University, Nabeshima 5-1-1, Saga, Japan
| |
Collapse
|
10
|
Nakashima T, Morimoto T, Hashimoto A, Kii S, Tsukamoto M, Miyamoto H, Todo M, Sonohata M, Mawatari M. Osteoconductivity and neurotoxicity of silver-containing hydroxyapatite coating cage for spinal interbody fusion in rats. JOR Spine 2023; 6:e1236. [PMID: 36994462 PMCID: PMC10041372 DOI: 10.1002/jsp2.1236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 10/27/2022] [Accepted: 11/21/2022] [Indexed: 12/03/2022] Open
Abstract
Background The use of spinal instrumentation is an established risk factor for postoperative infection. To address this problem, we prepared silver-containing hydroxyapatite coating, consisting of highly osteoconductive hydroxyapatite interfused with silver. The technology has been adopted for total hip arthroplasty. Silver-containing hydroxyapatite coating has been reported to have good biocompatibility and low toxicity. However, no studies about applying this coating in spinal surgery have addressed the osteoconductivity and direct neurotoxicity to the spinal cord of silver-containing hydroxyapatite cages in spinal interbody fusion. Aim In this study, we evaluated the osteoconductivity and neurotoxicity of silver-containing hydroxyapatite-coated implants in rats. Materials & Methods Titanium (non-coated, hydroxyapatite-coated, and silver-containing hydroxyapatite-coated) interbody cages were inserted into the spine for anterior lumbar fusion. At 8 weeks postoperatively, micro-computed tomography and histology were performed to evaluate the osteoconductivity of the cage. Inclined plane test and toe pinch test were performed postoperatively to assess neurotoxicity. Results Micro-computed tomography data indicated no significant difference in bone volume/total volume among the three groups. Histologically, the hydroxyapatite-coated and silver-containing hydroxyapatite-coated groups showed significantly higher bone contact rate than that of the titanium group. In contrast, there was no significant difference in bone formation rate among the three groups. Data of inclined plane and toe pinch test showed no significant loss of motor and sensory function in the three groups. Furthermore, there was no degeneration, necrosis, or accumulation of silver in the spinal cord on histology. Conclusions This study suggests that silver-hydroxyapatite-coated interbody cages produce good osteoconductivity and are not associated with direct neurotoxicity.
Collapse
Affiliation(s)
- Takema Nakashima
- Department of Orthopaedic Surgery, Faculty of MedicineSaga UniversitySagaJapan
| | - Tadatsugu Morimoto
- Department of Orthopaedic Surgery, Faculty of MedicineSaga UniversitySagaJapan
| | - Akira Hashimoto
- Department of Orthopaedic Surgery, Faculty of MedicineSaga UniversitySagaJapan
| | - Sakumo Kii
- Department of Orthopaedic Surgery, Faculty of MedicineSaga UniversitySagaJapan
| | - Masatsugu Tsukamoto
- Department of Orthopaedic Surgery, Faculty of MedicineSaga UniversitySagaJapan
| | - Hiroshi Miyamoto
- Department of Pathology and Microbiology, Faculty of MedicineSaga UniversitySagaJapan
| | - Mitsugu Todo
- Division of Renewable Energy Dynamics, Research Institute for Applied MechanicsKyushu UniversityFukuokaJapan
| | - Motoki Sonohata
- Department of Orthopaedic Surgery, Faculty of MedicineSaga UniversitySagaJapan
| | - Masaaki Mawatari
- Department of Orthopaedic Surgery, Faculty of MedicineSaga UniversitySagaJapan
| |
Collapse
|
11
|
Li H, Wang D, Zhang W, Xu G, Xu C, Liu W, Li J. Potential side effects of antibacterial coatings in orthopaedic implants: A systematic review of clinical studies. Front Bioeng Biotechnol 2023; 11:1111386. [PMID: 36845182 PMCID: PMC9947536 DOI: 10.3389/fbioe.2023.1111386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Accepted: 01/31/2023] [Indexed: 02/11/2023] Open
Abstract
Objective: The systematic review aimed to determine the potential side effects of antibacterial coatings in orthopaedic implants. Methods: Publications were searched in the databases of Embase, PubMed, Web of Science and Cochrane Library using predetermined keywords up to 31 October 2022. Clinical studies reporting side effects of the surface or coating materials were included. Results: A total of 23 studies (20 cohort studies and three case reports) reporting the concerns about the side effects of antibacterial coatings were identified. Three types of coating materials, silver, iodine and gentamicin were included. All of studies raised the concerns regarding safety of antibacterial coatings, and the occurrence of adverse events was observed in seven studies. The main side effect of silver coatings was the development of argyria. For iodine coatings, only one anaphylactic case was reported as an adverse event. No systemic or other general side effects were reported for gentamicin. Conclusion: Clinical studies on the side effects of antibacterial coatings were limited. Based on the available outcomes, the most reported side effects of antibacterial coatings in clinical use were argyria with silver coatings. However, researchers should always pay attention to the potential side effects of antibacterial materials, such as systematic or local toxicity and allergy.
Collapse
Affiliation(s)
- Hua Li
- Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China,National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China
| | - Daofeng Wang
- Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China,National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China
| | - Wupeng Zhang
- Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China,National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China,School of Medicine, Nankai University, Tianjin, China
| | - Gaoxiang Xu
- Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China,National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China
| | - Cheng Xu
- Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China,National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China,*Correspondence: Cheng Xu, ; Wanheng Liu, ; Jiantao Li,
| | - Wanheng Liu
- Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China,National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China,*Correspondence: Cheng Xu, ; Wanheng Liu, ; Jiantao Li,
| | - Jiantao Li
- Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China,National Clinical Research Center for Orthopedics, Sports Medicine and Rehabilitation, Beijing, China,*Correspondence: Cheng Xu, ; Wanheng Liu, ; Jiantao Li,
| |
Collapse
|
12
|
Bottagisio M, Palombella S, Lopa S, Sangalli F, Savadori P, Biagiotti M, Sideratou Z, Tsiourvas D, Lovati AB. Vancomycin-nanofunctionalized peptide-enriched silk fibroin to prevent methicillin-resistant Staphylococcus epidermidis-induced femoral nonunions in rats. Front Cell Infect Microbiol 2023; 12:1056912. [PMID: 36683682 PMCID: PMC9851397 DOI: 10.3389/fcimb.2022.1056912] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 12/19/2022] [Indexed: 01/06/2023] Open
Abstract
Introduction Implant-related infections and infected fractures are significant burdens in orthopedics. Staphylococcus epidermidis is one of the main causes of bone infections related to biofilm formation upon implants. Current antibiotic prophylaxis/therapy is often inadequate to prevent biofilm formation and results in antibiotic resistance. The development of bioactive materials combining antimicrobial and osteoconductive properties offers great potential for the eradication of microorganisms and for the enhancement of bone deposition in the presence of infections. The purpose of this study is to prevent the development of methicillin-resistant S. epidermidis (MRSE)-infected nonunion in a rat model. Methods To this end, a recently developed in our laboratories bioactive material consisting of antibiotic-loaded nanoparticles based on carboxylic acid functionalized hyperbranched aliphatic polyester (CHAP) that are integrated into peptide-enriched silk fibroin sponges with osteoconductive properties (AFN-PSF) was employed, whose biocompatibility and microbiological tests provided proof of its potential for the treatment of both orthopedic and dental infections. In particular, non-critical femoral fractures fixed with plates and screws were performed in Wistar rats, which were then randomly divided into three groups: 1) the sham control (no infection, no treatment); 2) the control group, infected with MRSE and treated with peptide-enriched silk fibroin sponges incorporating non-drug-loaded functionalized nanoparticles (PSF); 3) the treated group, infected with MRSE and treated with peptide-enriched silk fibroin sponges incorporating vancomycin-loaded functionalized nanoparticles (AFN-PSF). After 8 weeks, bone healing and osteomyelitis were clinically assessed and evaluated by micro-CT, microbiological and histological analyses. Results The sham group showed no signs of infection and complete bone healing. The PSF group failed to repair the infected fracture, displaying 75% of altered bone healing and severe signs of osteomyelitis. The AFN-PSF treated group reached 70% of fracture healing in the absence of signs of osteomyelitis, such as abscesses in the cortical and intraosseous compartments and bone necrosis with sequestra. Discussion AFN-PSF sponges have proven effective in preventing the development of infected nonunion in vivo. The proposed nanotechnology for local administration of antibiotics can have a significant impact on patient health in the case of orthopedic infections.
Collapse
Affiliation(s)
- Marta Bottagisio
- IRCCS Istituto Ortopedico Galeazzi, Laboratory of Clinical Chemistry and Microbiology, Milan, Italy
| | - Silvia Palombella
- IRCCS Istituto Ortopedico Galeazzi, Cell and Tissue Engineering Laboratory, Milan, Italy
| | - Silvia Lopa
- IRCCS Istituto Ortopedico Galeazzi, Cell and Tissue Engineering Laboratory, Milan, Italy
| | - Fabio Sangalli
- IRCCS Istituto di Ricerche Farmacologiche Mario Negri, Laboratory of Renal Biophysics, Department of Biomedical Engineering, Bergamo, Italy
| | - Paolo Savadori
- IRCCS Istituto Ortopedico Galeazzi, Department of Endodontics, Milan, Italy
| | | | - Zili Sideratou
- National Centre for Scientific Research "Demokritos", Institute of Nanoscience and Nanotechnology, Aghia Paraskevi, Greece
| | - Dimitris Tsiourvas
- National Centre for Scientific Research "Demokritos", Institute of Nanoscience and Nanotechnology, Aghia Paraskevi, Greece
| | - Arianna B Lovati
- IRCCS Istituto Ortopedico Galeazzi, Cell and Tissue Engineering Laboratory, Milan, Italy
| |
Collapse
|
13
|
Choi S, Lee H, Hong R, Jo B, Jo S. Application of Multi-Layered Temperature-Responsive Polymer Brushes Coating on Titanium Surface to Inhibit Biofilm Associated Infection in Orthopedic Surgery. Polymers (Basel) 2022; 15:polym15010163. [PMID: 36616511 PMCID: PMC9823637 DOI: 10.3390/polym15010163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 12/25/2022] [Accepted: 12/28/2022] [Indexed: 12/31/2022] Open
Abstract
Infection associated with biomedical implants remains the main cause of failure, leading to reoperation after orthopedic surgery. Orthopedic infections are characterized by microbial biofilm formation on the implant surface, which makes it challenging to diagnose and treat. One potential method to prevent and treat such complications is to deliver a sufficient dose of antibiotics at the onset of infection. This strategy can be realized by coating the implant with thermoregulatory polymers and triggering the release of antibiotics during the acute phase of infection. We developed a multi-layered temperature-responsive polymer brush (MLTRPB) coating that can release antibiotics once the temperature reaches a lower critical solution temperature (LCST). The coating system was developed using copolymers composed of diethylene glycol methyl ether methacrylate and 2-hydroxyethyl methacrylate by alternatively fabricating monomers layer by layer on the titanium surface. LCST was set to the temperature of 38-40 °C, a local temperature that can be reached during infection. The antibiotic elution characteristics were investigated, and the antimicrobial efficacy was tested against S. aureus species (Xen29 ATCC 29 213) using one to four layers of MLTRPB. Both in vitro and in vivo assessments demonstrated preventive effects when more than four layers of the coating were applied, ensuring promising antibacterial effects of the MLTRPB coating.
Collapse
Affiliation(s)
- Sookyung Choi
- School of Medicine, Chosun University Medical School, Gwangju 61452, Republic of Korea
| | - Hyeonjoon Lee
- Department of Orthopedic Surgery, Chosun University Hospital, Gwangju 61453, Republic of Korea
| | - Ran Hong
- School of Medicine, Chosun University Medical School, Gwangju 61452, Republic of Korea
- Department of Pathology, Chosun University Hospital, Gwangju 61453, Republic of Korea
| | - Byungwook Jo
- School of Engineering, Chosun University, Gwangju 61452, Republic of Korea
| | - Suenghwan Jo
- School of Medicine, Chosun University Medical School, Gwangju 61452, Republic of Korea
- Department of Orthopedic Surgery, Chosun University Hospital, Gwangju 61453, Republic of Korea
- Correspondence: ; Tel.: +82-62-220-3147
| |
Collapse
|
14
|
Li J, Cheung WH, Chow SK, Ip M, Leung SYS, Wong RMY. Current therapeutic interventions combating biofilm-related infections in orthopaedics : a systematic review of in vivo animal studies. Bone Joint Res 2022; 11:700-714. [PMID: 36214177 PMCID: PMC9582863 DOI: 10.1302/2046-3758.1110.bjr-2021-0495.r3] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Aims Biofilm-related infection is a major complication that occurs in orthopaedic surgery. Various treatments are available but efficacy to eradicate infections varies significantly. A systematic review was performed to evaluate therapeutic interventions combating biofilm-related infections on in vivo animal models. Methods Literature research was performed on PubMed and Embase databases. Keywords used for search criteria were “bone AND biofilm”. Information on the species of the animal model, bacterial strain, evaluation of biofilm and bone infection, complications, key findings on observations, prevention, and treatment of biofilm were extracted. Results A total of 43 studies were included. Animal models used included fracture-related infections (ten studies), periprosthetic joint infections (five studies), spinal infections (three studies), other implant-associated infections, and osteomyelitis. The most common bacteria were Staphylococcus species. Biofilm was most often observed with scanning electron microscopy. The natural history of biofilm revealed that the process of bacteria attachment, proliferation, maturation, and dispersal would take 14 days. For systemic mono-antibiotic therapy, only two of six studies using vancomycin reported significant biofilm reduction, and none reported eradication. Ten studies showed that combined systemic and topical antibiotics are needed to achieve higher biofilm reduction or eradication, and the effect is decreased with delayed treatment. Overall, 13 studies showed promising therapeutic potential with surface coating and antibiotic loading techniques. Conclusion Combined topical and systemic application of antimicrobial agents effectively reduces biofilm at early stages. Future studies with sustained release of antimicrobial and biofilm-dispersing agents tailored to specific pathogens are warranted to achieve biofilm eradication. Cite this article: Bone Joint Res 2022;11(10):700–714.
Collapse
Affiliation(s)
- Jie Li
- Department of Orthopaedics & Traumatology, The Chinese University of Hong Kong, Hong Kong, China
| | - Wing-Hoi Cheung
- Department of Orthopaedics & Traumatology, The Chinese University of Hong Kong, Hong Kong, China
| | - Simon K. Chow
- Department of Orthopaedics & Traumatology, The Chinese University of Hong Kong, Hong Kong, China
| | - Margaret Ip
- Department of Microbiology, The Chinese University of Hong Kong, Hong Kong, China
| | - Sharon Y. S. Leung
- School of Pharmacy, The Chinese University of Hong Kong, Hong Kong, China
| | - Ronald M. Y. Wong
- Department of Orthopaedics & Traumatology, The Chinese University of Hong Kong, Hong Kong, China, Ronald Man Yeung Wong. E-mail:
| |
Collapse
|
15
|
Miwa S, Yamamoto N, Hayashi K, Takeuchi A, Igarashi K, Tsuchiya H. Surgical Site Infection after Bone Tumor Surgery: Risk Factors and New Preventive Techniques. Cancers (Basel) 2022; 14:cancers14184527. [PMID: 36139686 PMCID: PMC9497226 DOI: 10.3390/cancers14184527] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Revised: 09/14/2022] [Accepted: 09/15/2022] [Indexed: 11/16/2022] Open
Abstract
The management of malignant bone tumors requires multidisciplinary interventions including chemotherapy, radiation therapy, and surgical tumor resection and reconstruction. Surgical site infection (SSI) is a serious complication in the treatment of malignant bone tumors. Compared to other orthopedic surgeries, the surgical treatment of malignant bone tumors is associated with higher rates of SSIs. In patients with SSIs, additional surgeries, long-term administrations of antibiotics, extended hospital stays, and the postponement of scheduled adjuvant treatments are required. Therefore, SSI may adversely affect functional and oncological outcomes. To improve surgical outcomes in patients with malignant bone tumors, preoperative risk assessments for SSIs, new preventive techniques against SSIs, and the optimal use of prophylactic antibiotics are often required. Previous reports have demonstrated that age, tumor site (pelvis and tibia), extended operative time, implant use, body mass index, leukocytopenia, and reconstruction procedures are associated with an increased risk for SSIs. Furthermore, prophylactic techniques, such as silver and iodine coatings on implants, have been developed and proven to be efficacious and safe in clinical studies. In this review, predictive factors of SSIs and new prophylactic techniques are discussed.
Collapse
|
16
|
Zinc Imidazolate Metal–Organic Frameworks-8-Encapsulated Enzymes/Nanoenzymes for Biocatalytic and Biomedical Applications. Catal Letters 2022. [DOI: 10.1007/s10562-022-04140-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
17
|
Huang LZY, Elbourne A, Shaw ZL, Cheeseman S, Goff A, Orrell-Trigg R, Chapman J, Murdoch BJ, Crawford RJ, Friedmann D, Bryant SJ, Truong VK, Caruso RA. Dual-action silver functionalized nanostructured titanium against drug resistant bacterial and fungal species. J Colloid Interface Sci 2022; 628:1049-1060. [PMID: 36049281 DOI: 10.1016/j.jcis.2022.08.052] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/20/2022] [Accepted: 08/09/2022] [Indexed: 10/15/2022]
Abstract
HYPOTHESIS Titanium and its alloys are commonly used implant materials. Once inserted into the body, the interface of the biomaterials is the most likely site for the development of implant-associated infections. Imparting the titanium substrate with high-aspect-ratio nanostructures, which can be uniformly achieved using hydrothermal etching, enables a mechanical contact-killing (mechanoresponsive) mechanism of bacterial and fungal cells. Interaction between cells and the surface shows cellular inactivation via a physical mechanism meaning that careful engineering of the interface is needed to optimse the technology. This mechanism of action is only effective towards surface adsorbed microbes, thus any cells not directly in contact with the substrate will survive and limit the antimicrobial efficacy of the titanium nanostructures. Therefore, we propose that a dual-action mechanoresponsive and chemical-surface approach must be utilised to improve antimicrobial activity. The addition of antimicrobial silver nanoparticles will provide a secondary, chemical mechanism to escalate the microbial response in tandem with the physical puncture of the cells. EXPERIMENTS Hydrothermal etching is used as a facile method to impart variant nanostrucutres on the titanium substrate to increase the antimicrobial response. Increasing concentrations (0.25 M, 0.50 M, 1.0 M, 2.0 M) of sodium hydroxide etching solution were used to provide differing degrees of nanostructured morphology on the surface after 3 h of heating at 150 °C. This produced titanium nanospikes, nanoblades, and nanowires, respectively, as a function of etchant concentration. These substrates then provided an interface for the deposition of silver nanoparticles via a reduction pathway. Methicillin-resistant Staphylococcous aureus (MRSA) and Candida auris (C. auris) were used as model bacteria and fungi, respectively, to test the effectiveness of the nanostructured titanium with and without silver nanoparticles, and the bio-interactions at the interface. FINDINGS The presence of nanostructure increased the bactericidal response of titanium against MRSA from ∼ 10 % on commercially pure titanium to a maximum of ∼ 60 % and increased the fungicidal response from ∼ 10 % to ∼ 70 % in C. auris. Introducing silver nanoparticles increased the microbiocidal response to ∼ 99 % towards both bacteria and fungi. Importantly, this study highlights that nanostructure alone is not sufficient to develop a highly antimicrobial titanium substrate. A dual-action, physical and chemical antimicrobial approach is better suited to produce highly effective antibacterial and antifungal surface technologies.
Collapse
Affiliation(s)
- Louisa Z Y Huang
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia
| | - Aaron Elbourne
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia.
| | - Z L Shaw
- School of Engineering, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia
| | - Samuel Cheeseman
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia
| | - Abigail Goff
- School of Engineering, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia
| | - Rebecca Orrell-Trigg
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia
| | - James Chapman
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia
| | - Billy J Murdoch
- RMIT Microscopy and Microanalysis Facility, RMIT University, Melbourne, Victoria 3000, Australia
| | - Russell J Crawford
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia
| | - Donia Friedmann
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia; School of Chemical Engineering, UNSW Engineering, UNSW, Sydney, New South Wales 2052, Australia
| | - Saffron J Bryant
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia
| | - Vi Khanh Truong
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia; College of Medicine and Public Health, Flinders University, Bedford Park, South Australia, Australia.
| | - Rachel A Caruso
- School of Science, College of STEM, RMIT University, Melbourne, Victoria 3000, Australia.
| |
Collapse
|
18
|
Laubach M, Kobbe P, Hutmacher DW. Biodegradable interbody cages for lumbar spine fusion: Current concepts and future directions. Biomaterials 2022; 288:121699. [PMID: 35995620 DOI: 10.1016/j.biomaterials.2022.121699] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 07/14/2022] [Accepted: 07/22/2022] [Indexed: 11/16/2022]
Abstract
Lumbar fusion often remains the last treatment option for various acute and chronic spinal conditions, including infectious and degenerative diseases. Placement of a cage in the intervertebral space has become a routine clinical treatment for spinal fusion surgery to provide sufficient biomechanical stability, which is required to achieve bony ingrowth of the implant. Routinely used cages for clinical application are made of titanium (Ti) or polyetheretherketone (PEEK). Ti has been used since the 1980s; however, its shortcomings, such as impaired radiographical opacity and higher elastic modulus compared to bone, have led to the development of PEEK cages, which are associated with reduced stress shielding as well as no radiographical artefacts. Since PEEK is bioinert, its osteointegration capacity is limited, which in turn enhances fibrotic tissue formation and peri-implant infections. To address shortcomings of both of these biomaterials, interdisciplinary teams have developed biodegradable cages. Rooted in promising preclinical large animal studies, a hollow cylindrical cage (Hydrosorb™) made of 70:30 poly-l-lactide-co-d, l-lactide acid (PLDLLA) was clinically studied. However, reduced bony integration and unfavourable long-term clinical outcomes prohibited its routine clinical application. More recently, scaffold-guided bone regeneration (SGBR) with application of highly porous biodegradable constructs is emerging. Advancements in additive manufacturing technology now allow the cage designs that match requirements, such as stiffness of surrounding tissues, while providing long-term biomechanical stability. A favourable clinical outcome has been observed in the treatment of various bone defects, particularly for 3D-printed composite scaffolds made of medical-grade polycaprolactone (mPCL) in combination with a ceramic filler material. Therefore, advanced cage design made of mPCL and ceramic may also carry initial high spinal forces up to the time of bony fusion and subsequently resorb without clinical side effects. Furthermore, surface modification of implants is an effective approach to simultaneously reduce microbial infection and improve tissue integration. We present a design concept for a scaffold surface which result in osteoconductive and antimicrobial properties that have the potential to achieve higher rates of fusion and less clinical complications. In this review, we explore the preclinical and clinical studies which used bioresorbable cages. Furthermore, we critically discuss the need for a cutting-edge research program that includes comprehensive preclinical in vitro and in vivo studies to enable successful translation from bench to bedside. We develop such a conceptual framework by examining the state-of-the-art literature and posing the questions that will guide this field in the coming years.
Collapse
Affiliation(s)
- Markus Laubach
- Australian Research Council (ARC) Training Centre for Cell and Tissue Engineering Technologies, Queensland University of Technology (QUT), Brisbane, QLD, 4000 Australia; Australian Research Council (ARC) Training Centre for Multiscale 3D Imaging, Modelling, and Manufacturing (M3D Innovation), Queensland University of Technology, Brisbane, QLD 4000, Australia; Centre for Biomedical Technologies, School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD 4059, Australia; Department of Orthopaedics, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074 Aachen, Germany.
| | - Philipp Kobbe
- Department of Orthopaedics, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074 Aachen, Germany
| | - Dietmar W Hutmacher
- Australian Research Council (ARC) Training Centre for Cell and Tissue Engineering Technologies, Queensland University of Technology (QUT), Brisbane, QLD, 4000 Australia; Australian Research Council (ARC) Training Centre for Multiscale 3D Imaging, Modelling, and Manufacturing (M3D Innovation), Queensland University of Technology, Brisbane, QLD 4000, Australia; Centre for Biomedical Technologies, School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, QLD 4059, Australia; Max Planck Queensland Center for the Materials Science of Extracellular Matrices, Queensland University of Technology, Brisbane, QLD 4000, Australia.
| |
Collapse
|
19
|
Park J, Chi L, Kwon HY, Lee J, Kim S, Hong S. Decaffeinated green tea extract as a nature-derived antibiotic alternative: An application in antibacterial nano-thin coating on medical implants. Food Chem 2022; 383:132399. [DOI: 10.1016/j.foodchem.2022.132399] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 02/04/2022] [Accepted: 02/07/2022] [Indexed: 11/17/2022]
|
20
|
Bläsius F, Delbrück H, Hildebrand F, Hofmann UK. Surgical Treatment of Bone Sarcoma. Cancers (Basel) 2022; 14:cancers14112694. [PMID: 35681674 PMCID: PMC9179414 DOI: 10.3390/cancers14112694] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 05/22/2022] [Accepted: 05/24/2022] [Indexed: 12/24/2022] Open
Abstract
Bone sarcomas are rare primary malignant mesenchymal bone tumors. The three main entities are osteosarcoma, chondrosarcoma, and Ewing sarcoma. While prognosis has improved for affected patients over the past decades, bone sarcomas are still critical conditions that require an interdisciplinary diagnostic and therapeutic approach. While radiotherapy plays a role especially in Ewing sarcoma and chemotherapy in Ewing sarcoma and osteosarcoma, surgery remains the main pillar of treatment in all three entities. After complete tumor resection, the created bone defects need to be reconstructed. Possible strategies are implantation of allografts or autografts including vascularized bone grafts (e.g., of the fibula). Around the knee joint, rotationplasty can be performed or, as an alternative, the implantation of (expandable) megaprostheses can be performed. Challenges still associated with the implantation of foreign materials are aseptic loosening and infection. Future improvements may come with advances in 3D printing of individualized resection blades/implants, thus also securing safe tumor resection margins while at the same time shortening the required surgical time. Faster osseointegration and lower infection rates may possibly be achieved through more elaborate implant surface structures.
Collapse
Affiliation(s)
- Felix Bläsius
- Department of Orthopaedic, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074 Aachen, Germany; (F.B.); (H.D.); (F.H.)
- Centre for Integrated Oncology Aachen Bonn Köln Düsseldorf (CIO), 52074 Aachen, Germany
| | - Heide Delbrück
- Department of Orthopaedic, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074 Aachen, Germany; (F.B.); (H.D.); (F.H.)
- Centre for Integrated Oncology Aachen Bonn Köln Düsseldorf (CIO), 52074 Aachen, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074 Aachen, Germany; (F.B.); (H.D.); (F.H.)
- Centre for Integrated Oncology Aachen Bonn Köln Düsseldorf (CIO), 52074 Aachen, Germany
| | - Ulf Krister Hofmann
- Department of Orthopaedic, Trauma and Reconstructive Surgery, RWTH Aachen University Hospital, Pauwelsstraße 30, 52074 Aachen, Germany; (F.B.); (H.D.); (F.H.)
- Centre for Integrated Oncology Aachen Bonn Köln Düsseldorf (CIO), 52074 Aachen, Germany
- Correspondence: ; Tel.: +49-(0)241-80-89350
| |
Collapse
|
21
|
Development of Silver-Containing Hydroxyapatite-Coated Antimicrobial Implants for Orthopaedic and Spinal Surgery. Medicina (B Aires) 2022; 58:medicina58040519. [PMID: 35454358 PMCID: PMC9029955 DOI: 10.3390/medicina58040519] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 03/30/2022] [Accepted: 03/30/2022] [Indexed: 11/30/2022] Open
Abstract
The prevention of surgical site infections is directly related to the minimization of surgical invasiveness, and is in line with the concept of minimally invasive spine therapy (MIST). In recent years, the incidence of postoperative infections has been increasing due to the increased use of spinal implant surgery in patients at high risk of infection, including the elderly and easily infected hosts, the limitations of poor bone marrow transfer of antibiotics, and the potential for contamination of surgical gloves and instruments. Thus, the development of antimicrobial implants in orthopedic and spinal surgery is becoming more and more popular, and implants with proven antimicrobial, safety, and osteoconductive properties (i.e., silver, iodine, antibiotics) in vitro, in vivo, and in clinical trials have become available for clinical use. We have developed silver-containing hydroxyapatite (Ag-HA)-coated implants to prevent post-operative infection, and increase bone fusion capacity, and have successfully commercialized antibacterial implants for hip prostheses and spinal interbody cages. This narrative review overviews the present status of available surface coating technologies and materials; describes how the antimicrobial, safety, and biocompatibility (osteoconductivity) of Ag-HA-coated implants have been demonstrated for commercialization; and reviews the clinical use of antimicrobial implants in orthopedic and spinal surgery, including Ag-HA-coated implants that we have developed.
Collapse
|
22
|
Elsadek NE, Nagah A, Ibrahim TM, Chopra H, Ghonaim GA, Emam SE, Cavalu S, Attia MS. Electrospun Nanofibers Revisited: An Update on the Emerging Applications in Nanomedicine. MATERIALS 2022; 15:ma15051934. [PMID: 35269165 PMCID: PMC8911671 DOI: 10.3390/ma15051934] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 01/31/2022] [Accepted: 02/08/2022] [Indexed: 02/06/2023]
Abstract
Electrospinning (ES) has become a straightforward and customizable drug delivery technique for fabricating drug-loaded nanofibers (NFs) using various biodegradable and non-biodegradable polymers. One of NF's pros is to provide a controlled drug release through managing the NF structure by changing the spinneret type and nature of the used polymer. Electrospun NFs are employed as implants in several applications including, cancer therapy, microbial infections, and regenerative medicine. These implants facilitate a unique local delivery of chemotherapy because of their high loading capability, wide surface area, and cost-effectiveness. Multi-drug combination, magnetic, thermal, and gene therapies are promising strategies for improving chemotherapeutic efficiency. In addition, implants are recognized as an effective antimicrobial drug delivery system overriding drawbacks of traditional antibiotic administration routes such as their bioavailability and dosage levels. Recently, a sophisticated strategy has emerged for wound healing by producing biomimetic nanofibrous materials with clinically relevant properties and desirable loading capability with regenerative agents. Electrospun NFs have proposed unique solutions, including pelvic organ prolapse treatment, viable alternatives to surgical operations, and dental tissue regeneration. Conventional ES setups include difficult-assembled mega-sized equipment producing bulky matrices with inadequate stability and storage. Lately, there has become an increasing need for portable ES devices using completely available off-shelf materials to yield highly-efficient NFs for dressing wounds and rapid hemostasis. This review covers recent updates on electrospun NFs in nanomedicine applications. ES of biopolymers and drugs is discussed regarding their current scope and future outlook.
Collapse
Affiliation(s)
- Nehal E. Elsadek
- Department of Pharmacokinetics and Biopharmaceutics, Institute of Biomedical Sciences, Tokushima University, 1-78-1 Sho-machi, Tokushima 770-8505, Japan;
| | - Abdalrazeq Nagah
- Faculty of Pharmacy, Zagazig University, Zagazig 44519, Egypt; (A.N.); (G.A.G.)
| | - Tarek M. Ibrahim
- Department of Pharmaceutics, Faculty of Pharmacy, Zagazig University, Zagazig 44519, Egypt; (T.M.I.); (S.E.E.)
| | - Hitesh Chopra
- Chitkara College of Pharmacy, Chitkara University, Punjab 140401, India;
| | - Ghada A. Ghonaim
- Faculty of Pharmacy, Zagazig University, Zagazig 44519, Egypt; (A.N.); (G.A.G.)
| | - Sherif E. Emam
- Department of Pharmaceutics, Faculty of Pharmacy, Zagazig University, Zagazig 44519, Egypt; (T.M.I.); (S.E.E.)
| | - Simona Cavalu
- Faculty of Medicine and Pharmacy, University of Oradea, P-ta 1 Decembrie 10, 410087 Oradea, Romania
- Correspondence: (S.C.); (M.S.A.)
| | - Mohamed S. Attia
- Department of Pharmaceutics, Faculty of Pharmacy, Zagazig University, Zagazig 44519, Egypt; (T.M.I.); (S.E.E.)
- Correspondence: (S.C.); (M.S.A.)
| |
Collapse
|
23
|
Addressing the Needs of the Rapidly Aging Society through the Development of Multifunctional Bioactive Coatings for Orthopedic Applications. Int J Mol Sci 2022; 23:ijms23052786. [PMID: 35269928 PMCID: PMC8911303 DOI: 10.3390/ijms23052786] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 02/27/2022] [Accepted: 02/28/2022] [Indexed: 12/15/2022] Open
Abstract
The unprecedented aging of the world's population will boost the need for orthopedic implants and expose their current limitations to a greater extent due to the medical complexity of elderly patients and longer indwelling times of the implanted materials. Biocompatible metals with multifunctional bioactive coatings promise to provide the means for the controlled and tailorable release of different medications for patient-specific treatment while prolonging the material's lifespan and thus improving the surgical outcome. The objective of this work is to provide a review of several groups of biocompatible materials that might be utilized as constituents for the development of multifunctional bioactive coatings on metal materials with a focus on antimicrobial, pain-relieving, and anticoagulant properties. Moreover, the review presents a summary of medications used in clinical settings, the disadvantages of the commercially available products, and insight into the latest development strategies. For a more successful translation of such research into clinical practice, extensive knowledge of the chemical interactions between the components and a detailed understanding of the properties and mechanisms of biological matter are required. Moreover, the cost-efficiency of the surface treatment should be considered in the development process.
Collapse
|
24
|
Lex JR, Koucheki R, Stavropoulos NA, Michele JD, Toor JS, Tsoi K, Ferguson PC, Turcotte RE, Papagelopoulos PJ. Megaprosthesis anti-bacterial coatings: A comprehensive translational review. Acta Biomater 2022; 140:136-148. [PMID: 34879295 DOI: 10.1016/j.actbio.2021.11.045] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 11/29/2021] [Accepted: 11/30/2021] [Indexed: 12/15/2022]
Abstract
Periprosthetic joint infections (PJI) are catastrophic complications for patients with implanted megaprostheses and pose significant challenges in the management of orthopaedic oncology patients. Despite various preventative strategies, with the increasing rate of implanted orthopaedic prostheses, the number of PJIs may be increasing. PJIs are associated with a high rate of amputation. Therefore, novel strategies to combat bacterial colonization and biofilm formation are required. A promising strategy is the utilization of anti-bacterial coatings on megaprosthetic implants. In this translational review, a brief overview of the mechanism of bacterial colonization of implants and biofilm formation will be provided, followed by a discussion and classification of major anti-bacterial coatings currently in use and development. In addition, current in vitro outcomes, clinical significance, economic importance, evolutionary perspectives, and future directions of anti-bacterial coatings will also be discussed. Megaprosthetic anti-bacterial coating strategies will help reduce infection rates following the implantation of megaprostheses and would positively impact sarcoma care. STATEMENT OF SIGNIFICANCE: This review highlights the clinical challenges and a multitude of potential solutions to combating peri-prosthetic join infections in megaprotheses using anti-bacterial coatings. Reducing infection rates following the implantation of megaprostheses would have a major impact on sarcoma care and major trauma surgeries that require reconstruction of large skeletal defects.
Collapse
Affiliation(s)
- Johnathan R Lex
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Canada
| | - Robert Koucheki
- Temerty Faculty of Medicine, University of Toronto, Toronto, Canada; Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
| | | | - Joseph Di Michele
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Canada
| | - Jay S Toor
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Canada
| | - Kim Tsoi
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Canada; Institute of Biomedical Engineering, University of Toronto, Toronto, Canada; University Musculoskeletal Oncology Unit, Mount Sinai Hospital, Toronto, Canada
| | - Peter C Ferguson
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Canada; University Musculoskeletal Oncology Unit, Mount Sinai Hospital, Toronto, Canada
| | - Robert E Turcotte
- Division of Orthopedic Surgery, McGill University Health Centre, Montreal, Canada
| | - Panayiotis J Papagelopoulos
- 1st Department of Orthopaedic Surgery, School of Medicine, National and Kapodistrian University of Athens, Greece
| |
Collapse
|
25
|
Goetz J, Keyssner V, Hanses F, Greimel F, Leiß F, Schwarz T, Springorum HR, Grifka J, Schaumburger J. Animal experimental investigation on the efficacy of antibiotic therapy with linezolid, vancomycin, cotrimoxazole, and rifampin in treatment of periprosthetic knee joint infections by MRSA. Bone Joint Res 2022; 11:143-151. [PMID: 35227086 PMCID: PMC8962855 DOI: 10.1302/2046-3758.113.bjr-2021-0268.r1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aims Periprosthetic joint infections (PJIs) are rare, but represent a great burden for the patient. In addition, the incidence of methicillin-resistant Staphylococcus aureus (MRSA) is increasing. The aim of this rat experiment was therefore to compare the antibiotics commonly used in the treatment of PJIs caused by MRSA. Methods For this purpose, sterilized steel implants were implanted into the femur of 77 rats. The metal devices were inoculated with suspensions of two different MRSA strains. The animals were divided into groups and treated with vancomycin, linezolid, cotrimoxazole, or rifampin as monotherapy, or with combination of antibiotics over a period of 14 days. After a two-day antibiotic-free interval, the implant was explanted, and bone, muscle, and periarticular tissue were microbiologically analyzed. Results Vancomycin and linezolid were able to significantly (p < 0.05) reduce the MRSA bacterial count at implants. No significant effect was found at the bone. Rifampin was the only monotherapy that significantly reduced the bacterial count on implant and bone. The combination with vancomycin or linezolid showed significant efficacy. Treatment with cotrimoxazole alone did not achieve a significant bacterial count reduction. The combination of linezolid plus rifampin was significantly more effective on implant and bone than the control group in both trials. Conclusion Although rifampicin is effective as a monotherapy, it should not be used because of the high rate of resistance development. Our animal experiments showed the great importance of combination antibiotic therapies. In the future, investigations with higher case numbers, varied bacterial concentrations, and changes in individual drug dosages will be necessary to be able to draw an exact comparison, possibly within a clinical trial. Cite this article: Bone Joint Res 2022;11(3):143–151.
Collapse
Affiliation(s)
- Julia Goetz
- Department of Orthopaedic Surgery, University Hospital Regensburg - Asklepios Bad Abbach, Regensburg, Germany
| | - Verena Keyssner
- Department of Orthopaedic Surgery, University Hospital Regensburg - Asklepios Bad Abbach, Regensburg, Germany
| | - Frank Hanses
- Department of Infectology, University Hospital Regensburg, Regensburg, Germany
| | - Felix Greimel
- Department of Orthopaedic Surgery, University Hospital Regensburg - Asklepios Bad Abbach, Regensburg, Germany
| | - Franziska Leiß
- Department of Orthopaedic Surgery, University Hospital Regensburg - Asklepios Bad Abbach, Regensburg, Germany
| | - Timo Schwarz
- Department of Orthopaedic Surgery, University Hospital Regensburg - Asklepios Bad Abbach, Regensburg, Germany
| | - Hans-Robert Springorum
- Department of Orthopaedic Surgery, University Hospital Regensburg - Asklepios Bad Abbach, Regensburg, Germany
| | - Joachim Grifka
- Department of Orthopaedic Surgery, University Hospital Regensburg - Asklepios Bad Abbach, Regensburg, Germany
| | - Jens Schaumburger
- Department of Orthopaedic Surgery, University Hospital Regensburg - Asklepios Bad Abbach, Regensburg, Germany
| |
Collapse
|
26
|
Antibacterial and Immunomodulatory Properties of Acellular Wharton’s Jelly Matrix. Biomedicines 2022; 10:biomedicines10020227. [PMID: 35203437 PMCID: PMC8869352 DOI: 10.3390/biomedicines10020227] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 01/10/2022] [Accepted: 01/17/2022] [Indexed: 12/13/2022] Open
Abstract
Of all biologic matrices, decellularized tissues have emerged as a promising tool in the field of regenerative medicine. Few empirical clinical studies have shown that Wharton’s jelly (WJ) of the human umbilical cord promotes wound closure and reduces wound-related infections. In this scope, we herein investigated whether decellularized (DC)-WJ could be used as an engineered biomaterial. In comparison with devitalized (DV)-WJ, our results showed an inherent effect of DC-WJ on Gram positive (S. aureus and S. epidermidis) and Gram negative (E. coli and P. aeruginosa) growth and adhesion. Although DC-WJ activated the neutrophils and monocytes in a comparable magnitude to DV-WJ, macrophages modulated their phenotypes and polarization states from the resting M0 phenotype to the hybrid M1/M2 phenotype in the presence of DC-WJ. M1 phenotype was predominant in the presence of DV-WJ. Finally, the subcutaneous implantation of DC-WJ showed total resorption after three weeks of implantation without any sign of foreign body reaction. These significant data shed light on the potential regenerative application of DC-WJ in providing a suitable biomaterial for tissue regenerative medicine and an ideal strategy to prevent wound-associated infections.
Collapse
|
27
|
One-Stage Hip Revision Arthroplasty Using Megaprosthesis in Severe Bone Loss of The Proximal Femur Due to Radiological Diffuse Osteomyelitis. Trop Med Infect Dis 2021; 7:tropicalmed7010005. [PMID: 35051121 PMCID: PMC8780561 DOI: 10.3390/tropicalmed7010005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 12/23/2021] [Accepted: 12/26/2021] [Indexed: 11/17/2022] Open
Abstract
Managing substantial proximal and/or distal femoral bone defects is one of the biggest challenges in chronic hip periprosthetic joint infection. Most authors use two-stage arthroplasty with a temporary antibiotic-loaded cement spacer for the management of these patients. In this study, we show our experience with one-stage exchange arthroplasty in managing severe bone defects due to radiological-extensive proximal femoral osteomyelitis. Two patients were included in the study. They showed radiological-extensive proximal femoral osteomyelitis, and they were treated with one-stage exchange arthroplasty using megaprosthesis. Diffuse osteomyelitis was confirmed in both cases; in one case, the histology was compatible with osteomyelitis, and the other case had a positive culture identified in a bone sample. At a minimum of a four-year follow-up, the patients did not reveal any clinical, radiological or laboratory signs of infection. In conclusion, one-stage exchange arthroplasty and megaprosthesis is an option for the treatment of chronic hip periprosthetic joint infection associated with radiological-diffuse proximal femoral osteomyelitis.
Collapse
|
28
|
Mude H, Maroju PA, Balapure A, Ganesan R, Ray Dutta J. Quaternized Polydopamine Coatings for Anchoring Molecularly Dispersed Broad-Spectrum Antimicrobial Silver Salts. ACS APPLIED BIO MATERIALS 2021; 4:8396-8406. [PMID: 35005936 DOI: 10.1021/acsabm.1c00952] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Because of the broad-spectrum antimicrobial efficacy, silver-based coatings have emerged as the popular choice to apply over frequently touched surfaces for mitigating the spread of nosocomial infections. Despite the advancements through various coating strategies, clustering of the active component remains a bottleneck in achieving the molecular-scale dispersion of silver. To circumvent this, the current study takes advantage of the recent findings of quaternary ammonium moieties forming molecular complexes with silver salts that differ from the simple adduct between the individual components. Here we demonstrate the quaternization of oxidatively cross-linked polydopamine coatings over magnetite nanoparticles to anchor ionic silver at a molecular-scale dispersion. The silver-derivatized materials exhibit remarkable broad-spectrum antimicrobial properties against representative microbes like E. coli, S. aureus, and A. niger. Also, the study reveals the materials' antibiofilm efficacy (∼80-90%) against both bacteria. Further recyclability studies have proven the sustained bactericidal properties up to five cycles. The surface derivatization strategy has then been extended to cover glass slips that have also shown the retention of the bactericidal properties even after wiping 20 times with artificial sweat. The biocompatibility of the materials has been ascertained with treated water against the mouse fibroblast and human embryonic kidney cell lines. The current study offers insights in developing coatings with molecular-scale dispersion of ionic silver to achieve broad-spectrum antimicrobial properties in an atom-economical and sustainable manner.
Collapse
Affiliation(s)
- Hemanjali Mude
- Department of Biological Sciences, Birla Institute of Technology and Science (BITS), Pilani, Hyderabad Campus, Jawahar Nagar, Kapra Mandal, Medchal District, Hyderabad, Telangana 500078, India
| | - Pranay Amruth Maroju
- Department of Biological Sciences, Birla Institute of Technology and Science (BITS), Pilani, Hyderabad Campus, Jawahar Nagar, Kapra Mandal, Medchal District, Hyderabad, Telangana 500078, India
| | - Aniket Balapure
- Department of Chemistry, Birla Institute of Technology and Science (BITS), Pilani, Hyderabad Campus, Jawahar Nagar, Kapra Mandal, Medchal District, Hyderabad, Telangana 500078, India
| | - Ramakrishnan Ganesan
- Department of Chemistry, Birla Institute of Technology and Science (BITS), Pilani, Hyderabad Campus, Jawahar Nagar, Kapra Mandal, Medchal District, Hyderabad, Telangana 500078, India
| | - Jayati Ray Dutta
- Department of Biological Sciences, Birla Institute of Technology and Science (BITS), Pilani, Hyderabad Campus, Jawahar Nagar, Kapra Mandal, Medchal District, Hyderabad, Telangana 500078, India
| |
Collapse
|
29
|
Maliuchenko LI, Nikolaev NS, Pchelova NN, Nikolaevich Efimov D, Preobrazhenskaia EV, Emelianov VU. Linear-Chain Nanostructured Carbon with a Silver Film Plated on Metal Components Has a Promising Effect for the Treatment of Periprosthetic Joint Infection. OSTEOLOGY 2021; 1:238-246. [DOI: https:/doi.org/10.3390/osteology1040022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2023]
Abstract
Background: Due to the aging of the world population, the number of joint diseases, along with the number of arthroplasties, has increased, simultaneously increasing the amount of complications, including periprosthetic joint infection (PPI). In this study, to combat a PPI, we investigated the antimicrobial properties of the new composite cover for titanium implants, silver-doped carbyne-like carbon (S-CLC) film. Methods: The first assay investigated the antimicrobial activity against Pseudomonas aeruginosa and releasing of silver ions from S-CLC films into growth media covered with S-CLC with a thickness of 1, 2, and 4 mm. The second assay determined the direct antibacterial properties of the S-CLC film’s surface against Staphylococcus aureus, Enterococcus faecalis, or P. aeruginosa. The third assay studied the formation of microbial biofilms of S. aureus or P. aeruginosa on the S-CLC coating. Silver-doped carbyne-like carbon (S-CLC)-covered or titanium plates alone were used as controls. Results: S-CLC films, compared to controls, prevented P. aeruginosa growth on 1 mm thickness agar; had direct antimicrobial properties against S. aureus, E. faecalis, and P. aeruginosa; and could prevent P. aeruginosa biofilm formation. Conclusions: S-CLC films on the Ti surface could successfully fight the most common infectious agent in PPI, and prevented biofilm formation.
Collapse
Affiliation(s)
- Leonid I. Maliuchenko
- Federal Center for Traumatology, Orthopedics and Arthroplasty, 428020 Cheboksary, Russia
| | - Nikolay S. Nikolaev
- Federal Center for Traumatology, Orthopedics and Arthroplasty, 428020 Cheboksary, Russia
- Faculty of Medicine, Chuvash State University, 428020 Cheboksary, Russia
| | - Nadezhda N. Pchelova
- Federal Center for Traumatology, Orthopedics and Arthroplasty, 428020 Cheboksary, Russia
| | | | | | - Vladimir U. Emelianov
- Federal Center for Traumatology, Orthopedics and Arthroplasty, 428020 Cheboksary, Russia
- Faculty of Medicine, Chuvash State University, 428020 Cheboksary, Russia
| |
Collapse
|
30
|
Tsikopoulos K, Sidiropoulos K, Kitridis D, Moulder E, Ahmadi M, Drago L, Lavalette D. Preventing Staphylococcus aureus stainless steel-associated infections in orthopedics. A systematic review and meta-analysis of animal literature. J Orthop Res 2021; 39:2615-2637. [PMID: 33527485 DOI: 10.1002/jor.24999] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 01/17/2021] [Accepted: 01/25/2021] [Indexed: 02/04/2023]
Abstract
Surgical site infection in the presence of orthopedic implants poses significant healthcare and socioeconomic burden. To assess the potential of various prevention strategies against Staphylococcus-induced stainless steel-associated infections, a review of animal evidence was designed. The databases of PubMed, Embase, and CENTRAL were searched until March 10, 2020, for articles including animal models with stainless steel instrumentation and techniques to prevent Staphylococcus infection. We conducted a random-effects meta-analysis of standardized mean differences (SMD) with subgroup analysis linked to various protection strategies and we recorded complications. Quality was assessed with the SYRCLE's risk of bias tool. Twenty-five studies were included. Combined active coating (featuring organic antibacterial compound release) and degradable passive finishing (lipid- or polymer-based structure modification reducing bacterial adhesion) was favored over untreated controls (SMDs for methicillin-sensitive Staphylococcus aureus [MSSA] and methicillin-resistant Staphylococcus aureus [MRSA] were -3.46, 95% CI [-4.53 to -2.4], p < .001 [n = 4 head-to-head comparisons]; and -6.67, 95% CI [-10.53 to -3], p < .001 [n = 5 head-to-head comparisons], respectively). Systemic vitamin D supplementation and systemic antibiotic administration with or without local antibiotics demonstrated favorable outcomes against MSSA infection. On the contrary, no benefit was seen following vaccination. Of note, no side effects were documented. On the basis of data gathered from eight studies, which comprised 294 animals, a bioresorbable polymer- or lipid-based surface modification supplemented with organic coating yielded improved infection-related outcomes against MSSA and MRSA stainless steel infections, and therefore, this strategy could be further investigated in human research.
Collapse
Affiliation(s)
| | | | - Dimitrios Kitridis
- 1st Orthopedic Department, G. Papanikolaou General Hospital, Aristotle University, Thessaloniki, Greece
| | - Elizabeth Moulder
- Orthopedic Department, Hull Limb Reconstruction Unit, Hull Royal Infirmary, Hull, UK
| | - Milad Ahmadi
- Orthopaedic Department, Leeds General Infirmary, Leeds, UK
| | - Lorenzo Drago
- Laboratory of Clinical Microbiology, Department of Biochemical Sciences for Health, University of Milan, Milan, Italy
| | - David Lavalette
- Orthopedic Department, Harrogate and District NHS Foundation Trust, Harrogate, UK
| |
Collapse
|
31
|
Novel Catalytic Ceramic Conversion Treatment of Ti6Al4V for Improved Tribological and Antibacterial Properties for Biomedical Applications. MATERIALS 2021; 14:ma14216554. [PMID: 34772075 PMCID: PMC8585320 DOI: 10.3390/ma14216554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 10/28/2021] [Accepted: 10/28/2021] [Indexed: 11/16/2022]
Abstract
Titanium oxide layers were produced via a novel catalytic ceramic conversion treatment (CCCT, C3T) on Ti-6Al-4V. This CCCT process is carried out by applying thin catalytic films of silver and palladium onto the substrate before an already established traditional ceramic conversion treatment (CCT, C2T) is carried out. The layers were characterised using scanning electron microscopy, X-ray diffraction, transmission electron microscopy; surface micro-hardness and reciprocating tribological performance was assessed; antibacterial performance was also assessed with S. aureus. This CCCT has been shown to increase the oxide thickness from ~5 to ~100 µm, with the production of an aluminium rich layer and agglomerates of silver and palladium oxide surrounded by vanadium oxide at the surface. The wear factor was significantly reduced from ~393 to ~5 m3/N·m, and a significant reduction in the number of colony-forming units per ml of Staphylococcus aureus on the CCCT surfaces was observed. The potential of the novel C3T treatment has been demonstrated by comparing the performance of C3T treated and untreated Ti6Al4V fixation pins through inserting into simulated bone materials.
Collapse
|
32
|
Esteban J, Vallet-Regí M, Aguilera-Correa JJ. Antibiotics- and Heavy Metals-Based Titanium Alloy Surface Modifications for Local Prosthetic Joint Infections. Antibiotics (Basel) 2021; 10:1270. [PMID: 34680850 PMCID: PMC8532710 DOI: 10.3390/antibiotics10101270] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 10/05/2021] [Accepted: 10/13/2021] [Indexed: 01/04/2023] Open
Abstract
Prosthetic joint infection (PJI) is the second most common cause of arthroplasty failure. Though infrequent, it is one of the most devastating complications since it is associated with great personal cost for the patient and a high economic burden for health systems. Due to the high number of patients that will eventually receive a prosthesis, PJI incidence is increasing exponentially. As these infections are provoked by microorganisms, mainly bacteria, and as such can develop a biofilm, which is in turn resistant to both antibiotics and the immune system, prevention is the ideal approach. However, conventional preventative strategies seem to have reached their limit. Novel prevention strategies fall within two broad categories: (1) antibiotic- and (2) heavy metal-based surface modifications of titanium alloy prostheses. This review examines research on the most relevant titanium alloy surface modifications that use antibiotics to locally prevent primary PJI.
Collapse
Affiliation(s)
- Jaime Esteban
- Clinical Microbiology Department, Jiménez Díaz Foundation Health Research Institute, Autonomous University of Madrid, Av. Reyes Católicos 2, 28040 Madrid, Spain
- Networking Research Centre on Infectious Diseases (CIBER-ID), 28029 Madrid, Spain
| | - María Vallet-Regí
- Department of Chemistry in Pharmaceutical Sciences, Research Institute Hospital 12 de Octubre (i+12), School of Pharmacy, Complutense University of Madrid, Pza. Ramón y Cajal s/n, 28040 Madrid, Spain
- Networking Research Centre on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, Spain
| | - John J Aguilera-Correa
- Networking Research Centre on Infectious Diseases (CIBER-ID), 28029 Madrid, Spain
- Department of Chemistry in Pharmaceutical Sciences, Research Institute Hospital 12 de Octubre (i+12), School of Pharmacy, Complutense University of Madrid, Pza. Ramón y Cajal s/n, 28040 Madrid, Spain
| |
Collapse
|
33
|
Wang Q, Wang W, Li Y, Li W, Tan L, Yang K. Biofunctional magnesium coating of implant materials by physical vapour deposition. BIOMATERIALS TRANSLATIONAL 2021; 2:248-256. [PMID: 35836651 PMCID: PMC9255807 DOI: 10.12336/biomatertransl.2021.03.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 07/31/2021] [Accepted: 09/10/2021] [Indexed: 11/17/2022]
Abstract
The lack of bioactivity of conventional medical materials leads to low osseointegration ability that may result in the occurrence of aseptic loosening in the clinic. To achieve high osseointegration, surface modifications with multiple biofunctions including degradability, osteogenesis, angiogenesis and antibacterial properties are required. However, the functions of conventional bioactive coatings are limited. Thus novel biofunctional magnesium (Mg) coatings are believed to be promising candidates for surface modification of implant materials for use in bone tissue repair. By physical vapour deposition, many previous researchers have deposited Mg coatings with high purity and granular microstructure on titanium alloys, polyetheretherketone, steels, Mg alloys and silicon. It was found that the Mg coatings with high-purity could considerably control the degradation rate in the initial stage of Mg alloy implantation, which is the most important problem for the application of Mg alloy implants. In addition, Mg coating on titanium (Ti) implant materials has been extensively studied both in vitro and in vivo, and the results indicated that their corrosion behaviour and biocompatibility are promising. Mg coatings continuously release Mg ions during the degradation process, and the alkaline environment caused by Mg degradation has obvious antibacterial effects. Meanwhile, the Mg coating has beneficial effects on osteogenesis and osseointegration, and increases the new bone-regenerating ability. Mg coatings also exhibit favourable osteogenic and angiogenic properties in vitro and increased long-term bone formation and early vascularization in vivo. Inhibitory effects of Mg coatings on osteoclasts have also been proven, which play a great role in osteoporotic patients. In addition, in order to obtain more biofunctions, other alloying elements such as copper have been added to the Mg coatings. Thus, Mg-coated Ti acquired biofunctions including degradability, osteogenesis, angiogenesis and antibacterial properties. These novel multi-functional Mg coatings are expected to significantly enhance the long-term safety of bone implants for the benefit of patients. This paper gives a brief review of studies of the microstructure, degradation behaviours and biofunctions of Mg coatings, and directions for future research are also proposed.
Collapse
Affiliation(s)
- Qingchuan Wang
- Department of Advanced Materials Research, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, Liaoning Province, China
| | - Weidan Wang
- Department of Advanced Materials Research, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, Liaoning Province, China,Department of Orthopaedic Surgery, Affiliated Zhongshan Hospital of Dalian University, Dalian, Liaoning Province, China
| | - Yanfang Li
- Dongguan Eontec Co. Ltd., Dongguan, Guangdong Province, China
| | - Weirong Li
- Dongguan Eontec Co. Ltd., Dongguan, Guangdong Province, China
| | - Lili Tan
- Department of Advanced Materials Research, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, Liaoning Province, China,Corresponding authors: Lili Tan, ; Ke Yang,
| | - Ke Yang
- Department of Advanced Materials Research, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, Liaoning Province, China,Corresponding authors: Lili Tan, ; Ke Yang,
| |
Collapse
|
34
|
Singh J, Hegde PB, Ravindra P, Sen P, Avasthi S. Ambient Light-Activated Antibacterial Material: Manganese Vanadium Oxide (Mn 2V 2O 7). ACS APPLIED BIO MATERIALS 2021; 4:6903-6911. [DOI: 10.1021/acsabm.1c00605] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Jagriti Singh
- Centre for Nanoscience and Engineering, Indian Institute of Science, Bengaluru 560012, India
| | - Prajwal B. Hegde
- Centre for Nanoscience and Engineering, Indian Institute of Science, Bengaluru 560012, India
| | - Pramod Ravindra
- Centre for Nanoscience and Engineering, Indian Institute of Science, Bengaluru 560012, India
| | - Prosenjit Sen
- Centre for Nanoscience and Engineering, Indian Institute of Science, Bengaluru 560012, India
| | - Sushobhan Avasthi
- Centre for Nanoscience and Engineering, Indian Institute of Science, Bengaluru 560012, India
| |
Collapse
|
35
|
Niu WA, Rivera SL, Siegrist MS, Santore MM. Depletion forces drive reversible capture of live bacteria on non-adhesive surfaces. SOFT MATTER 2021; 17:8185-8194. [PMID: 34525168 DOI: 10.1039/d1sm00631b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Because bacterial adhesion to surfaces is associated with infections and biofilm growth, it has been a longstanding goal to develop coatings that minimize biomolecular adsorption and eliminate bacteria adhesion. We demonstrate that, even on carefully-engineered non-bioadhesive coatings such as polyethylene glycol (PEG) layers that prevent biomolecule adsorption and cell adhesion, depletion interactions from non-adsorbing polymer in solution (such as 10 K PEG or 100 K PEO) can cause adhesion and retention of Escherichia coli cells, defeating the antifouling functionality of the coating. The cells are immobilized and remain viable on the timescale of the study, at least up to 45 minutes. When the polymer solution is replaced by buffer, cells rapidly escape from the surface, consistent with expectations for the reversibility of depletion attractions. The dissolved polymer additionally causes cells to aggregate in solution and aggregates rapidly dissociate to singlets upon tenfold dilution in buffer, also consistent with depletion. Hydrodynamic forces can substantially reduce the adhesion of aggregates on surfaces in conditions where single cells adhere via depletion. The findings reported here suggest that because bacteria thrive in polymer-rich environments both in vivo and in situ, depletion interactions may make it impossible to avoid bacterial retention on surfaces.
Collapse
Affiliation(s)
- Wuqi Amy Niu
- Department of Polymer Science and Engineering, University of Massachusetts, Governors Drive, Amherst, MA 01003, USA.
| | - Sylvia L Rivera
- Department of Microbiology, University of Massachusetts, Amherst, MA 01003, USA
| | - M Sloan Siegrist
- Department of Microbiology, University of Massachusetts, Amherst, MA 01003, USA
- Molecular and Cellular Biology Graduate Program, University of Massachusetts, Amherst, MA 01003, USA
| | - Maria M Santore
- Department of Polymer Science and Engineering, University of Massachusetts, Governors Drive, Amherst, MA 01003, USA.
- Molecular and Cellular Biology Graduate Program, University of Massachusetts, Amherst, MA 01003, USA
| |
Collapse
|
36
|
Titanium implant coating based on dopamine-functionalized sulphated hyaluronic acid: in vivo assessment of biocompatibility and antibacterial efficacy. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 128:112286. [PMID: 34474837 DOI: 10.1016/j.msec.2021.112286] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 06/11/2021] [Accepted: 06/25/2021] [Indexed: 11/20/2022]
Abstract
The number of total knee and/or hip replacements are expected to exceed 5 million a year by 2030; the incidence of biofilm-associated complications can vary from 1% in primary implants to 5.6% in case of revision. The purpose of this study was to test the ability of sHA-DA, a partially sulphated hyaluronic acid (sHA) functionalized with a dopamine (DA) moiety, to prevent acute bacterial growth in an in vivo model of an intra-operatively highly contaminated implant. Previously, in vitro studies showed that the DA moiety guarantees good performance as binding agent for titanium surface adhesion, while the negatively charged sHA has both a high efficiency in electrostatic binding of positively charged antibiotics, and bone regenerative effects. The in vitro testing also highlighted the effectiveness of the sHA-DA system in inhibiting bacterial spreading through a sustained release of the antibiotic payload from the implant coating. In this study the chemical stability of the sHA-DA to β-ray sterilization was demonstrated, based on evaluation by NMR, SEC-TDA Omnisec and HPLC-MS analysis, thus supporting the approach of terminal sterilization of the coated implant with no loss of efficacy. Furthermore, an in vivo study in rabbits was performed according to UNI EN ISO 10993-6 to assess the histocompatibility of titanium nails pre-coated with sHA-DA. The implants, placed in the femoral medullary cavity and harvested after 12 weeks, proved to be histocompatible and to allow bone growth in adhesion to the metal surface. Finally, an in vivo model of bacterial contamination was set up by injecting 1 mL of bacterial suspension containing 104 or 106 CFU of methicillin-resistant Staphylococcus aureus (MRSA) into the femoral medullary cavity of 30 rabbits. Titanium nails either uncoated or pre-coated with sHA-DA and loaded directly by the surgeon with 5% vancomycin were implanted in the surgical site. After 1 week, only the animals treated with pre-coated nails did not show the presence of systemic or local bacterial infection, as confirmed by microbiology and histology (Smeltzer score). Further insights into the animal model setup are crucial, however the results obtained suggest that the system can be effective in preventing the onset of the bacterial infective process.
Collapse
|
37
|
Review on Surface Treatment for Implant Infection via Gentamicin and Antibiotic Releasing Coatings. COATINGS 2021. [DOI: 10.3390/coatings11081006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Surface treatment of metallic implants plays a crucial role in orthopedics and orthodontics. Metallic implants produce side-effects such as physical, chemical/electro-chemical irritations, oligodynamic/catalytic and carcinogenic effects. These effects cause bacterial infections and account for huge medical expenses. Treatment for these infections comprises repeated radical debridement, replacement of the implant device and intravenous or oral injection antibiotics. Infection is due to the presence of bacteria in the patient or the surrounding environment. The antibiotic-based medication prevents prophylaxis against bacterial colonization, which is an emphatic method that may otherwise be catastrophic to a patient. Therefore, preventive measures are essential. A coating process was developed with its drug infusion and effect opposing biofilms. Modification in the medical implant surface reduces the adhesion of bacterial and biofilms, the reason behind bacterial attachment. Other polymer-based and nanoparticle-based carriers are used to resolve implant infections. Therefore, using an implant coating is a better approach to prevent infection due to biofilm.
Collapse
|
38
|
Shen J, Sun D, Fu J, Wang S, Wang X, Xie Z. Management of surgical site infection post-open reduction and internal fixation for tibial plateau fractures. Bone Joint Res 2021; 10:380-387. [PMID: 34218687 PMCID: PMC8333030 DOI: 10.1302/2046-3758.107.bjr-2020-0175.r2] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
AIMS In contrast to operations performed for other fractures, there is a high incidence rate of surgical site infection (SSI) post-open reduction and internal fixation (ORIF) done for tibial plateau fractures (TPFs). This study investigates the effect of induced membrane technique combined with internal fixation for managing SSI in TPF patients who underwent ORIF. METHODS From April 2013 to May 2017, 46 consecutive patients with SSI post-ORIF for TPFs were managed in our centre with an induced membrane technique. Of these, 35 patients were included for this study, with data analyzed in a retrospective manner. RESULTS All participants were monitored for a mean of 36 months (24 to 62). None were subjected to amputations. A total of 21 patients underwent two-stage surgeries (Group A), with 14 patients who did not receive second-stage surgery (Group B). Group A did not experience infection recurrence, and no implant or cement spacer loosening was noted in Group B for at least 24 months of follow-up. No significant difference was noted in the Lower Extremity Functional Scale (LEFS) and the Hospital for Special Surgery Knee Score (HSS) between the two groups. The clinical healing time was significantly shorter in Group B (p<0.001). Those with longer duration of infection had poorer functional status (p<0.001). CONCLUSION Management of SSI post-ORIF for TPF with induced membrane technique combined with internal fixation represents a feasible mode of treatment with satisfactory outcomes in terms of infection control and functional recovery. Cite this article: Bone Joint Res 2021;10(7):380-387.
Collapse
Affiliation(s)
- Jie Shen
- National & Regional United Engineering Laboratory of Tissue Engineering, Department of Orthopaedics, Southwest Hospital, Army Medical University, Chongqing, China
| | - Dong Sun
- National & Regional United Engineering Laboratory of Tissue Engineering, Department of Orthopaedics, Southwest Hospital, Army Medical University, Chongqing, China
| | - Jingshu Fu
- National & Regional United Engineering Laboratory of Tissue Engineering, Department of Orthopaedics, Southwest Hospital, Army Medical University, Chongqing, China
| | - Shulin Wang
- National & Regional United Engineering Laboratory of Tissue Engineering, Department of Orthopaedics, Southwest Hospital, Army Medical University, Chongqing, China
| | - Xiaohua Wang
- National & Regional United Engineering Laboratory of Tissue Engineering, Department of Orthopaedics, Southwest Hospital, Army Medical University, Chongqing, China
| | - Zhao Xie
- National & Regional United Engineering Laboratory of Tissue Engineering, Department of Orthopaedics, Southwest Hospital, Army Medical University, Chongqing, China
| |
Collapse
|
39
|
Guerra J, Chaghouri P, Guerra JA, Peters SL. Total Femoral Replacement- A Case Report. Geriatr Orthop Surg Rehabil 2021; 12:21514593211019977. [PMID: 34211799 PMCID: PMC8216370 DOI: 10.1177/21514593211019977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Accepted: 04/29/2021] [Indexed: 11/21/2022] Open
Abstract
Total femoral replacement(TFR) is a well-recognized salvage procedure performed after multiple failed endoprosthetic replacements, which result in severely compromised bone stock and damaged structural integrity. TFR is performed as an alternative to lower limb amputation, restoring femoral integrity and enabling patients to resume ambulation. TFR is expected to be performed more frequently as the worldwide rate of revision arthroplasty increases due to improved patient survival rates and their underlying diseases, exceeding the functional life of endoprosthetic arthroplasty. We present a 74-year-old, overweight woman with an extensive surgical history with respect to her right knee. Her right lower extremity x-rays showed a long-cemented stem knee tumour prosthesis and a Garden 4 subcapital fracture of the ipsilateral hip. Due to multiple surgeries of the knee and femur in the past, a total femoral replacement was required to be performed. The procedure was successful, and the expected outcome was met. A successful procedure performed by a skilled and experienced surgical team, a thorough rehabilitation program, and prompt post-operative management of complications, can overcome the high incidence of infection and dislocation to preserve the limb with improved functionality and reduce pain. TFR is a drastic operative intervention that can preserve the quality of life for most patients.
Collapse
Affiliation(s)
- Jose Guerra
- Department of Surgery, University of Toronto, Scarborough Health Network, Ontario, Canada
| | - Patrick Chaghouri
- Department of Surgery, University of Toronto, Scarborough Health Network, Ontario, Canada
| | - Jose Andres Guerra
- Department of Surgery, University of Toronto, Scarborough Health Network, Ontario, Canada
| | - Sophia Lorina Peters
- Department of Surgery, University of Toronto, Scarborough Health Network, Ontario, Canada
| |
Collapse
|
40
|
Formulation of inherently antimicrobial magnesium oxychloride cement and the effect of supplementation with silver phosphate. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 126:112158. [PMID: 34082963 DOI: 10.1016/j.msec.2021.112158] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 04/19/2021] [Accepted: 04/26/2021] [Indexed: 11/22/2022]
Abstract
The growing threat of bacterial resistance to antibiotics is driving an increasing need for new antimicrobial strategies. This work demonstrates the potential of magnesium oxychloride cements (MOC) to be used as inorganic antimicrobial biomaterials for bone augmentation. An injectable formulation was identified at a powder to liquid ratio of 1.4 g mL-1, with an initial setting time below 30 mins and compressive strength of 35 ± 9 MPa. Supplementation with Ag3PO4 to enhance the antimicrobial efficacy of MOC was explored, and shown via real time X-ray diffraction to retard the formation of hydrated oxychloride phases by up to 30%. The antimicrobial efficacy of MOC was demonstrated in vitro against Staphylococcus aureus and Pseudomonas aeruginosa, forming zones of inhibition and significantly reducing viability in broth culture. Enhanced efficacy was seen for silver doped formulations, with complete eradication of detectable viable colonies within 3 h, whilst retaining the cytocompatibility of MOC. Investigating the antimicrobial mode of action revealed that Mg and Ag release and elevated pH contributed to MOC efficacy. Sustained silver release was demonstrated over 14 days, suggesting the Ag3PO4 modified formulation offers two mechanisms of infection treatment, combining the inherent antimicrobial properties of MOC with controlled release of inorganic antimicrobials.
Collapse
|
41
|
Borcherding K, Schmidmaier G, Hofmann GO, Wildemann B. The rationale behind implant coatings to promote osteointegration, bone healing or regeneration. Injury 2021; 52 Suppl 2:S106-S111. [PMID: 33257018 DOI: 10.1016/j.injury.2020.11.050] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 11/16/2020] [Indexed: 02/02/2023]
Abstract
Implant loosening, bone healing failure, implant-associated infections, and large bony defects remain challenges in orthopedic surgery. Implant surface modifications and coatings are being developed to promote osteointegration, prevent colonization by bacteria, and release bioactive factors. The following mini-review briefly discusses the clinical problem, explains the four "osteos", presents examples of coatings used for different orthopedic indications, and finally raises awareness of the coating and translational requirements.
Collapse
Affiliation(s)
- Kai Borcherding
- Department of Adhesive Bonding Technology and Surfaces, Fraunhofer Institute for Manufacturing Technology and Advanced Materials IFAM, Bremen, Germany
| | - Gerhard Schmidmaier
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, HTRG - Heidelberg Trauma Research Group, Heidelberg University Hospital, Heidelberg, Germany
| | - Gunther O Hofmann
- Department of Trauma, Hand and Reconstructive Surgery, Experimental Trauma Surgery, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany
| | - Britt Wildemann
- Department of Trauma, Hand and Reconstructive Surgery, Experimental Trauma Surgery, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany; Julius Wolff Institute, BIH Center for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
| |
Collapse
|
42
|
Fracture nonunion in long bones: A literature review of risk factors and surgical management. Injury 2021; 52 Suppl 2:S3-S11. [PMID: 33221036 DOI: 10.1016/j.injury.2020.11.029] [Citation(s) in RCA: 131] [Impact Index Per Article: 32.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 11/06/2020] [Accepted: 11/10/2020] [Indexed: 02/02/2023]
Abstract
Nonunion following a long bone fracture causes considerable morbidity when it occurs. Risk factors depend on specific fractures but there is a complex interplay of injury severity, comorbidities, patient medication and infection. The majority of nonunions occur after long bone fractures with the tibia, femur, forearm, humerus and clavicle predominating. Despite interest in the biological augmentation of fracture healing, the majority of nonunions can be effectively managed with conventional surgical techniques. In this review we present a review of risk factors for nonunion and the outcome following surgical management.
Collapse
|
43
|
Innovative Coatings of Metallic Alloys Used as Bioactive Surfaces in Implantology: A Review. COATINGS 2021. [DOI: 10.3390/coatings11060649] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Metallic implants are widely used in the field of implantology, but there are still problems leading to implant failures due to weak osseointegration, low mechanical strength for the implant, inadequate antibacterial properties, and low patient satisfaction. Implant failure can be caused by bacterial infections and poor osteointegration. To improve the implant functionalization, many researchers focus on surface modifications to prepare the proper physical and chemical conditions able to increase biocompatibility and osteointegration between implant and bone. Improving the antibacterial performance is also a key factor to avoid the inflammation in the human body. This paper is a brief review for the types of coatings used to increase osseointegration and biocompatibility for the successful use of metal alloys in the field of implantology.
Collapse
|
44
|
Scialla S, Martuscelli G, Nappi F, Singh SSA, Iervolino A, Larobina D, Ambrosio L, Raucci MG. Trends in Managing Cardiac and Orthopaedic Device-Associated Infections by Using Therapeutic Biomaterials. Polymers (Basel) 2021; 13:1556. [PMID: 34066192 PMCID: PMC8151391 DOI: 10.3390/polym13101556] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 05/08/2021] [Accepted: 05/10/2021] [Indexed: 12/23/2022] Open
Abstract
Over the years, there has been an increasing number of cardiac and orthopaedic implanted medical devices, which has caused an increased incidence of device-associated infections. The surfaces of these indwelling devices are preferred sites for the development of biofilms that are potentially lethal for patients. Device-related infections form a large proportion of hospital-acquired infections and have a bearing on both morbidity and mortality. Treatment of these infections is limited to the use of systemic antibiotics with invasive revision surgeries, which had implications on healthcare burdens. The purpose of this review is to describe the main causes that lead to the onset of infection, highlighting both the biological and clinical pathophysiology. Both passive and active surface treatments have been used in the field of biomaterials to reduce the impact of these infections. This includes the use of antimicrobial peptides and ionic liquids in the preventive treatment of antibiotic-resistant biofilms. Thus far, multiple in vivo studies have shown efficacious effects against the antibiotic-resistant biofilm. However, this has yet to materialize in clinical medicine.
Collapse
Affiliation(s)
- Stefania Scialla
- Institute of Polymers, Composites and Biomaterials of National Research Council (IPCB-CNR), 80125 Naples, Italy; (S.S.); (D.L.)
| | - Giorgia Martuscelli
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, 81100 Naples, Italy;
| | - Francesco Nappi
- Centre Cardiologie du Nord de Saint-Denis, Department of Cardiac Surgery, 93200 Paris, France; (F.N.); (A.I.)
| | | | - Adelaide Iervolino
- Centre Cardiologie du Nord de Saint-Denis, Department of Cardiac Surgery, 93200 Paris, France; (F.N.); (A.I.)
| | - Domenico Larobina
- Institute of Polymers, Composites and Biomaterials of National Research Council (IPCB-CNR), 80125 Naples, Italy; (S.S.); (D.L.)
| | - Luigi Ambrosio
- Institute of Polymers, Composites and Biomaterials of National Research Council (IPCB-CNR), 80125 Naples, Italy; (S.S.); (D.L.)
| | - Maria Grazia Raucci
- Institute of Polymers, Composites and Biomaterials of National Research Council (IPCB-CNR), 80125 Naples, Italy; (S.S.); (D.L.)
| |
Collapse
|
45
|
O'Donnell JA, Wu M, Cochrane NH, Belay E, Myntti MF, James GA, Ryan SP, Seyler TM. Efficacy of common antiseptic solutions against clinically relevant microorganisms in biofilm. Bone Joint J 2021; 103-B:908-915. [PMID: 33934664 DOI: 10.1302/0301-620x.103b5.bjj-2020-1245.r2] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Periprosthetic joint infections (PJIs) are among the most devastating complications after joint arthroplasty. There is limited evidence on the efficacy of different antiseptic solutions on reducing biofilm burden. The purpose of the present study was to test the efficacy of different antiseptic solutions against clinically relevant microorganisms in biofilm. METHODS We conducted an in vitro study examining the efficacy of several antiseptic solutions against clinically relevant microorganisms. We tested antiseptic irrigants against nascent (four-hour) and mature (three-day) single-species biofilm created in vitro using a drip-flow reactor model. RESULTS With regard to irrigant efficacy against biofilms, Povidone-iodine treatment resulted in greater reductions in nascent MRSA biofilms (logarithmic reduction (LR) = 3.12; p < 0.001) compared to other solutions. Bactisure treatment had the greatest reduction of mature Pseudomonas aeruginosa biofilms (LR = 1.94; p = 0.032) and a larger reduction than Vashe or Irrisept for mature Staphylococcus epidermidis biofilms (LR = 2.12; p = 0.025). Pooled data for all biofilms tested resulted in Bactisure and Povidone-iodine with significantly greater reductions compared to Vashe, Prontosan, and Irrisept solutions (p < 0.001). CONCLUSION Treatment failure in PJI is often due to failure to clear the biofilm; antiseptics are often used as an adjunct to biofilm clearance. We tested irrigants against clinically relevant microorganisms in biofilm in vitro and showed significant differences in efficacy among the different solutions. Further clinical outcome data is necessary to determine whether these solutions can impact PJI outcome in vivo. Cite this article: Bone Joint J 2021;103-B(5):908-915.
Collapse
Affiliation(s)
- Jeffrey A O'Donnell
- Department of Orthopaedics, Duke University Hospital, Durham, North Carolina, USA
| | - Mark Wu
- Department of Orthopaedics, Duke University Hospital, Durham, North Carolina, USA
| | - Niall H Cochrane
- Department of Orthopaedics, Duke University Hospital, Durham, North Carolina, USA
| | - Elshaday Belay
- Department of Orthopaedics, Duke University Hospital, Durham, North Carolina, USA
| | | | - Garth A James
- Medical Biofilms Laboratory Center for Biofilm Engineering, Montana State University, Bozeman, Montana, USA
| | - Sean P Ryan
- Department of Orthopaedics, Duke University Hospital, Durham, North Carolina, USA
| | - Thorsten M Seyler
- Department of Orthopaedics, Duke University Hospital, Durham, North Carolina, USA
| |
Collapse
|
46
|
Treatment of severely open tibial fractures, non-unions, and fracture-related infections with a gentamicin-coated tibial nail-clinical outcomes including quality of life analysis and psychological ICD-10-based symptom rating. J Orthop Surg Res 2021; 16:270. [PMID: 33865407 PMCID: PMC8052745 DOI: 10.1186/s13018-021-02411-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 04/06/2021] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Implant-associated infections depict a major challenge in orthopedics and trauma surgery putting a high burden on the patients and health care systems, strongly requiring improvement of infection prevention and of clinical outcomes. One strategy includes the usage of antimicrobial-coated implants. We evaluated outcomes after surgical treatment using a gentamicin-coated nail on (i) treatment success in terms of bone consolidation, (ii) absence of infection, and (iii) patient-reported quality of life in a patient cohort with high risk of infection/reinfection and treatment failure. METHODS Thirteen patients with open tibia fractures (n = 4), non-unions (n = 2), and fracture-related infection (n = 7) treated with a gentamicin-coated intramedullary nail (ETN ProtectTM) were retrospectively reviewed. Quality of life was evaluated with the EQ-5D, SF-36, and with an ICD-10-based symptom rating (ISR). RESULTS At a mean follow-up of 2.8 years, 11 of the 13 patients (84.6%) achieved bone consolidation without any additional surgical intervention, whereas two patients required a revision surgery due to infection and removal of the implant. No specific implant-related side effects were noted. Quality of life scores were significantly lower compared to a German age-matched reference population. The mean ISR scores revealed mild psychological symptom burden on the scale depression. CONCLUSION The use of a gentamicin-coated intramedullary nail seems to be reasonable in open fractures and revision surgery for aseptic non-union or established fracture-related infection to avoid infection complications and to achieve bony union. Despite successful treatment of challenging cases with the gentamicin-treated implant, significantly reduced quality of life after treatment underlines the need of further efforts to improve surgical treatment strategies and psychological support.
Collapse
|
47
|
Jastrzębski K, Białecki J, Jastrzębska A, Kaczmarek A, Para M, Niedzielski P, Bociaga D. Induced Biological Response in Contact with Ag-and Cu-Doped Carbon Coatings for Potential Orthopedic Applications. MATERIALS 2021; 14:ma14081861. [PMID: 33918582 PMCID: PMC8070217 DOI: 10.3390/ma14081861] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 04/05/2021] [Accepted: 04/06/2021] [Indexed: 12/12/2022]
Abstract
Silver and copper as additives of various biomaterials have been reported as the potential solutions for biomedicine applications, mostly because of inducing bactericidal effects. The application of those admixtures in diamond-like carbon (DLC) coatings may be desirable for orthopedic implants. In the present manuscript, the biological effect of coatings with up to about 7 at.% and 14 at.% of, respectively, Cu and Ag is compared. The morphology, chemical structure, and composition of films deposited on AISI 316LVM and Ti6Al7Nb is characterized. The live/dead analysis conducted with Escherichia coli shows a higher bactericidal potential of silver than copper. Although the Cu-doped coatings can positively affect the proliferation of Saos-2 and EA.hy926 cell lines, the results of XTT test are on the verge of 70% of viability. Biological effect of silver on EA.hy926 cell lines is negative but that admixture ensures high proliferation of osteoblasts in contact with coatings deposited on titanium alloy (over 20% better than for substrate material). In that case, the viability is reaching about 85% for Ag-doped coatings on AISI 316LVM and 75% on Ti6Al7Nb. The results indicate that for the sake of bactericidal coatings that may promote osteointegration, the candidates are DLC with silver content no higher than 10 at.%.
Collapse
Affiliation(s)
- Krzysztof Jastrzębski
- Institute of Materials Science and Engineering, Lodz University of Technology, 1/15 Stefanowskiego St., 90-924 Lodz, Poland; (A.J.); (P.N.); (D.B.)
- Correspondence:
| | - Jerzy Białecki
- Ortopaedic Clinic of Centre of Postgraduate Medical Education in Otwock, Konarskiego 13, 05-400 Otwock, Poland; (J.B.); (M.P.)
| | - Aleksandra Jastrzębska
- Institute of Materials Science and Engineering, Lodz University of Technology, 1/15 Stefanowskiego St., 90-924 Lodz, Poland; (A.J.); (P.N.); (D.B.)
| | - Anna Kaczmarek
- Lukasiewicz Research Network-Textile Research Institute, Brzezinska 5/15, 92-103 Lodz, Poland;
| | - Marcin Para
- Ortopaedic Clinic of Centre of Postgraduate Medical Education in Otwock, Konarskiego 13, 05-400 Otwock, Poland; (J.B.); (M.P.)
| | - Piotr Niedzielski
- Institute of Materials Science and Engineering, Lodz University of Technology, 1/15 Stefanowskiego St., 90-924 Lodz, Poland; (A.J.); (P.N.); (D.B.)
| | - Dorota Bociaga
- Institute of Materials Science and Engineering, Lodz University of Technology, 1/15 Stefanowskiego St., 90-924 Lodz, Poland; (A.J.); (P.N.); (D.B.)
| |
Collapse
|
48
|
Garg D, Matai I, Sachdev A. Toward Designing of Anti-infective Hydrogels for Orthopedic Implants: From Lab to Clinic. ACS Biomater Sci Eng 2021; 7:1933-1961. [PMID: 33826312 DOI: 10.1021/acsbiomaterials.0c01408] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
An alarming increase in implant failure incidence due to microbial colonization on the administered orthopedic implants has become a horrifying threat to replacement surgeries and related health concerns. In essence, microbial adhesion and its subsequent biofilm formation, antibiotic resistance, and the host immune system's deficiency are the main culprits. An advanced class of biomaterials termed anti-infective hydrogel implant coatings are evolving to subdue these complications. On this account, this review provides an insight into the significance of anti-infective hydrogels for preventing orthopedic implant associated infections to improve the bone healing process. We briefly discuss the clinical course of implant failure, with a prime focus on orthopedic implants. We identify the different anti-infective coating strategies and hence several anti-infective agents which could be incorporated in the hydrogel matrix. The fundamental design criteria to be considered while fabricating anti-infective hydrogels for orthopedic implants will be discussed. We highlight the different hydrogel coatings based on the origin of the polymers involved in light of their antimicrobial efficacy. We summarize the relevant patents reported in the prevention of implant infections, including orthopedics. Finally, the challenges concerning the clinical translation of the aforesaid hydrogels are described, and considerable solutions for improved clinical practice and better future prospects are proposed.
Collapse
Affiliation(s)
- Deepa Garg
- Central Scientific Instruments Organisation (CSIR-CSIO), Chandigarh-160030, India.,Academy of Scientific and Innovative Research, CSIR-CSIO, Chandigarh-160030, India
| | - Ishita Matai
- Central Scientific Instruments Organisation (CSIR-CSIO), Chandigarh-160030, India.,Academy of Scientific and Innovative Research, CSIR-CSIO, Chandigarh-160030, India
| | - Abhay Sachdev
- Central Scientific Instruments Organisation (CSIR-CSIO), Chandigarh-160030, India.,Academy of Scientific and Innovative Research, CSIR-CSIO, Chandigarh-160030, India
| |
Collapse
|
49
|
Clindamycin-Based 3D-Printed and Electrospun Coatings for Treatment of Implant-Related Infections. MATERIALS 2021; 14:ma14061464. [PMID: 33802712 PMCID: PMC8002500 DOI: 10.3390/ma14061464] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/10/2021] [Accepted: 03/15/2021] [Indexed: 02/07/2023]
Abstract
This study presents the development and characterisation of two novel bioactive coatings deposited on TiAlV and AISI 316LVM substrates. The coatings were prepared using 3D printing and electrospinning. The 3D-printed coating consisted of the cellulose nanofibril suspension, alginate, and carboxymethylcellulose (CMC), while CMC and polyethylene oxide were used to prepare the electrospun coating. Both coatings were loaded with the antibiotic clindamycin (CLIN), which is a bacteriostatic lincosamide known for its activity against streptococci, staphylococci, pneumococci, Bacteroides species, and other anaerobes. Initial characterisation of the coatings was performed by attenuated total reflectance Fourier transform infrared spectroscopy, field emission scanning electron microscopy, and atomic force microscopy. Furthermore, the contact angle measurements, swelling rate, and biodegradability of the coatings were investigated. The released concentration of CLIN in PBS (pH = 7.4 at 25 °C) was determined by UV-VIS spectrophotometry. The coatings’ biocompatibility was determined using an MTT (3(4,5 dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide) assay using an osteoblast cell culture (hFOB 1.19, ATCC CRL 11372).
Collapse
|
50
|
Tanner MC, Fischer C, Schmidmaier G, Haubruck P. Evidence-based uncertainty: do implant-related properties of titanium reduce the susceptibility to perioperative infections in clinical fracture management? A systematic review. Infection 2021; 49:813-821. [PMID: 33586124 PMCID: PMC8476472 DOI: 10.1007/s15010-021-01583-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 02/02/2021] [Indexed: 11/28/2022]
Abstract
Background Implant-associated infections (IAI) remain a challenging complication in osteosynthesis. There is no consensus or clear evidence whether titanium offers a relevant clinical benefit over stainless steel. Purpose In this systematic review, we sought to determine whether the implant properties of titanium reduce the susceptibility to IAI compared to stainless steel in fracture management. Methods A systematic literature search in German and English was performed using specific search terms and limits. Studies published between 1995 and 1st June 2020 in the Cochrane library, MEDLINE and Web of Science databases were included. Only clinical studies comparing titanium and stainless steel implants regarding the susceptibility to infections were selected for detailed review. Results Five studies out of 384 papers were identified and reviewed. From the studies meeting inclusion criteria one study was a systematic review, two studies were randomized controlled studies (RCT) and two studies were of retrospective comparative nature of level IV evidence. Conclusion Our results show that currently, no proven advantage for titanium implants in respect to IAI can be seen in contemporary literature. Implants preserving periosteal blood-flow and minimising soft-tissue trauma show statistically significant benefits in reducing the incidence of IAI. Clinical studies providing reliable evidence regarding the influence of titanium implants on IAI and investigating the susceptibility of titanium to infection are necessary
Collapse
Affiliation(s)
- Michael C Tanner
- HTRG-Heidelberg Trauma Research Group, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Trauma and Reconstructive Surgery, Heidelberg University Hospital, 69118, Heidelberg, Germany.
| | - Christian Fischer
- HTRG-Heidelberg Trauma Research Group, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Trauma and Reconstructive Surgery, Heidelberg University Hospital, 69118, Heidelberg, Germany
| | - Gerhard Schmidmaier
- HTRG-Heidelberg Trauma Research Group, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Trauma and Reconstructive Surgery, Heidelberg University Hospital, 69118, Heidelberg, Germany
| | - Patrick Haubruck
- HTRG-Heidelberg Trauma Research Group, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Trauma and Reconstructive Surgery, Heidelberg University Hospital, 69118, Heidelberg, Germany
| |
Collapse
|