1
|
Tene T, Bonilla García N, Marcatoma Tixi JA, Dávalos Villegas MX, Vacacela Gomez C, Bellucci S. Mathematical modeling of a MoSe₂-based SPR biosensor for detecting SARS-CoV-2 at nM concentrations. Front Bioeng Biotechnol 2025; 13:1547248. [PMID: 40092372 PMCID: PMC11907102 DOI: 10.3389/fbioe.2025.1547248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2024] [Accepted: 02/11/2025] [Indexed: 03/19/2025] Open
Abstract
The rapid and accurate detection of SARS-CoV-2 remains a critical challenge in biosensing technology, necessitating the development of highly sensitive and selective platforms. In this study, we present a mathematical modeling approach to optimize a MoSe₂-based Surface Plasmon Resonance (SPR) biosensor for detecting the novel coronavirus at nM scale. Using the Transfer Matrix Method (TMM), we systematically optimize the biosensor's structural parameters, including silver (Ag), silicon nitride (Si₃N₄), molybdenum diselenide (MoSe₂), and thiol-tethered single-stranded DNA (ssDNA) layers, to enhance sensitivity, detection accuracy, and optical performance. The results indicate that an optimized 45 nm Ag layer, 10 nm Si₃N₄ layer, and monolayer MoSe₂ configuration achieves a resonance shift (Δθ) of 0.3° at 100 nM, with a sensitivity of 197.70°/RIU and a detection accuracy of 5.24 × 10⁻2. Additionally, the incorporation of a 10 nm ssDNA functionalization layer significantly enhances molecular recognition, lowering the limit of detection (LoD) to 2.53 × 10⁻5 and improving overall biosensing efficiency. Sys₅ (MoSe₂ + ssDNA) outperforms Sys₄ (MoSe₂ without ssDNA) in terms of specificity and reliability, making it more suitable for practical applications. These findings establish the MoSe₂-based SPR biosensor as a highly promising candidate for SARS-CoV-2 detection, offering a balance between high sensitivity, optical stability, and molecular selectivity, crucial for effective viral diagnostics.
Collapse
Affiliation(s)
- Talia Tene
- Department of Chemistry, Universidad Técnica Particular de Loja, Loja, Ecuador
| | - Nataly Bonilla García
- Facultad de Ciencias, Escuela Superior Politécnica de Chimborazo (ESPOCH), Riobamba, Ecuador
| | | | | | | | | |
Collapse
|
2
|
Nga DTN, Mai QD, Nguyen LHT, Doan TLH, Thi Kim Oanh V, Ngoc Bach T, Dinh Lam V, Nguyen HA, Le AT. ZIP-8/Ag-based size-selective SERS nanoplatform for ultrasensitive urea detection in milk samples: effects of analyte molecular dimensions on adsorption capacity and sensing performance. RSC Adv 2025; 15:4915-4925. [PMID: 39957818 PMCID: PMC11823638 DOI: 10.1039/d4ra07695h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2024] [Accepted: 02/06/2025] [Indexed: 02/18/2025] Open
Abstract
Being well-known as an excellent sorbent, metal-organic frameworks (MOFs) have been employed to intergrate with noble metal nanoparticles to fabricate active substrates for surface-enhance Raman spectroscopy (SERS) sensing applications. In this work, we employed three organic molecules with different molecular dimensions, including urea, methylene blue (MB) and Congo red (CR) for investigating SERS performance of a ZIP-8/Ag heterostructure. While every dimension of urea is smaller than the pore size of ZIP-8, MB and CR has one dimension larger than that of the pore size. The results show that only urea experienced large SERS enhancements on ZIP-8/Ag sensing platform. In contrast, MB and CR exhibited lower SERS intensity on ZIP-8/Ag than on pure Ag nanoparticle substrates. Adsorption capacities of those analyte were then calculated to confirm that urea could be adsorbed into ZIP-8/Ag at the best rate. The size-dependent mechanism of analyte adsorption and improving SERS signal was then confirmed using two other organic compounds: 4-nitrophenol (4-NP) and chloramphenicol (CAP). Thanks to the size-selective adsorption, small molecules such as urea and 4-NP can be effectively detected in the presence of large interfering molecules, which is useful for developing advanced SERS applications. The ZIP-8/Ag-based SERS sensor could detect urea at impressive concentrations as low as 1.48 × 10-10 M in standard solutions and 10-8 M in milk.
Collapse
Affiliation(s)
- Dao Thi Nguyet Nga
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
| | - Quan Doan Mai
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
| | - Linh Ho Thuy Nguyen
- Center for Innovative Material and Architectures Ho Chi Minh City Vietnam
- Vietnam National University-Ho Chi Minh City Ho Chi Minh City Vietnam
| | - Tan Le Hoang Doan
- Center for Innovative Material and Architectures Ho Chi Minh City Vietnam
- Vietnam National University-Ho Chi Minh City Ho Chi Minh City Vietnam
| | - Vu Thi Kim Oanh
- Institute of Materials Science (IMS), Graduate University of Science and Technology (GUST), Vietnam Academy of Science and Technology 18 Hoang Quoc Viet Hanoi 10000 Vietnam
| | - Ta Ngoc Bach
- Institute of Materials Science (IMS), Graduate University of Science and Technology (GUST), Vietnam Academy of Science and Technology 18 Hoang Quoc Viet Hanoi 10000 Vietnam
| | - Vu Dinh Lam
- Institute of Materials Science (IMS), Graduate University of Science and Technology (GUST), Vietnam Academy of Science and Technology 18 Hoang Quoc Viet Hanoi 10000 Vietnam
| | - Ha Anh Nguyen
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
| | - Anh-Tuan Le
- Phenikaa University Nano Institute (PHENA), Phenikaa University Hanoi 12116 Vietnam
| |
Collapse
|
3
|
Ortega MAC, González Landaeta RE, Aguirre Tostado FS, Torres Argüelles SV, Carrillo Castillo A. Urea biosensors based in zeolites and chalcogenide-oxide semiconductor thin films as active materials: A review. Anal Biochem 2025; 696:115685. [PMID: 39374822 DOI: 10.1016/j.ab.2024.115685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Revised: 10/02/2024] [Accepted: 10/05/2024] [Indexed: 10/09/2024]
Abstract
Diagnosis of renal failure by measuring urea levels has been a topic of intense study in recent years. A major focus has been on improving the sensitivity, linearity, precision, accuracy, and selectivity of biosensors for measuring urea. Although various materials have been used in the fabrication of urea biosensors, ceramics, and chalcogenides have been less explored in this field. Recently, the use of ceramics such as zeolite has been investigated to improve enzyme immobilization methods in urea biosensors and their application in ion-selective membranes, to increase the specificity of the devices. While oxides have been widely used as transducers in urea biosensors, chalcogenide semiconductor materials from Group VI of the periodic table also show promising properties, such as chemical stability, to signal transduction capability, and improved electrical measurements. This review provides a comprehensive overview of recent research in urea biosensors, with a special emphasis on the use of ceramics for enzyme immobilization and chalcogenides as transducers and how these materials contribute to improving the performance of these devices.
Collapse
Affiliation(s)
- Manuel A Chairez Ortega
- Instituto de Ingeniería y Tecnología, Universidad Autónoma de Ciudad Juárez, Av. Del Charro 610, C.P. 32310 Ciudad Juárez, CHIH, Mexico
| | - Rafael E González Landaeta
- Instituto de Ingeniería y Tecnología, Universidad Autónoma de Ciudad Juárez, Av. Del Charro 610, C.P. 32310 Ciudad Juárez, CHIH, Mexico
| | - Francisco S Aguirre Tostado
- Centro de Investigación en Materiales Avanzados, S.C., Alianza Norte 202, Parque de Investigación e Innovación Tecnológica, C.P. 66600 Apodaca, NL, Mexico
| | - Soledad V Torres Argüelles
- Instituto de Ingeniería y Tecnología, Universidad Autónoma de Ciudad Juárez, Av. Del Charro 610, C.P. 32310 Ciudad Juárez, CHIH, Mexico
| | - Amanda Carrillo Castillo
- Instituto de Ingeniería y Tecnología, Universidad Autónoma de Ciudad Juárez, Av. Del Charro 610, C.P. 32310 Ciudad Juárez, CHIH, Mexico.
| |
Collapse
|
4
|
Houari F, El Barghouti M, Mir A, Akjouj A. Nanosensors Based on Bimetallic Plasmonic Layer and Black Phosphorus: Application to Urine Glucose Detection. SENSORS (BASEL, SWITZERLAND) 2024; 24:5058. [PMID: 39124105 PMCID: PMC11315007 DOI: 10.3390/s24155058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Revised: 07/26/2024] [Accepted: 07/31/2024] [Indexed: 08/12/2024]
Abstract
This paper presents a new biosensor design based on the Kretschmann configuration, for the detection of analytes at different refractive indices. Our studied design consists of a TiO2/SiO2 bi-layer sandwiched between a BK7 prism and a bimetallic layer of Ag/Au plasmonic materials, covered by a layer of black phosphorus placed below the analyte-containing detection medium. The different layers of our structure and analyte detection were optimized using the angular interrogation method. High performance was achieved, with a sensitivity of 240 deg/RIU and a quality factor of 34.7 RIU-1. This biosensor can detect analytes with a wide refractive index range between 1.330 and 1.347, such as glucose detection in urine samples using a refractive index variation of 10-3. This capability offers a wide range of applications for biomedical and biochemical detection and selectivity.
Collapse
Affiliation(s)
- Fatima Houari
- Laboratory of Advanced Materials Studies and Applications (LEM2A), Physics Department, Faculty of Science, Moulay Ismail University of Meknes, B.P. 11201 Zitoune Meknès, Morocco; (F.H.); or (M.E.B.); (A.M.)
| | - Mohamed El Barghouti
- Laboratory of Advanced Materials Studies and Applications (LEM2A), Physics Department, Faculty of Science, Moulay Ismail University of Meknes, B.P. 11201 Zitoune Meknès, Morocco; (F.H.); or (M.E.B.); (A.M.)
- Faculty of Medicine and Pharmacy of Beni Mellal, Sultane Moulay Slimane University, M’ghila Campus, 23030 Beni Mellal, Morocco
| | - Abdellah Mir
- Laboratory of Advanced Materials Studies and Applications (LEM2A), Physics Department, Faculty of Science, Moulay Ismail University of Meknes, B.P. 11201 Zitoune Meknès, Morocco; (F.H.); or (M.E.B.); (A.M.)
| | - Abdellatif Akjouj
- Univ. Lille, Institute of Electronics, Microelectronics and Nanotechnology, UMR CNRS 8520, FST, Department of Physics, 59655 Villeneuve d’Ascq, France
| |
Collapse
|
5
|
Servarayan KL, Sundaram E, Velayutham K, Aravind MK, Sundarapandi M, Ashokkumar B, Sivasamy VV. Simple enzyme based fluorimetric biosensor for urea in human biofluids. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 315:124271. [PMID: 38613899 DOI: 10.1016/j.saa.2024.124271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 04/02/2024] [Accepted: 04/07/2024] [Indexed: 04/15/2024]
Abstract
As an important biomarker for renal related diseases, detection of urea is playing a vital role in human biofluids on clinical diagnosis concern. In this work, a synthetic salicyaldehyde based imine fluorophore was synthesized using sonication method and conjugated with urease which was used as fluorescent biosensor for the detection of urea in serum samples. This enzyme based biosensor has shown a good selectivity and sensitivity towards urea with the linear range from 2 to 80 mM and the detection limit of 73 µM. The sensing response obtain is highly agreeing with existing analytical technique for urea detection which strongly recommends this biosensor for clinical application.
Collapse
Affiliation(s)
- Karthika Lakshmi Servarayan
- Department of Natural Products Chemistry, School of Chemistry, Madurai Kamaraj University, Madurai 625 021, Tamilnadu, India
| | - Ellairaja Sundaram
- Department of Chemistry, Vivekananda College, Tiruvedakam West, Madurai 625 234, Tamilnadu, India
| | | | - Manikka Kubendran Aravind
- Department of Genetic Engineering, School of Biotechnology, Madurai Kamaraj University, Madurai 625 021, Tamilnadu, India
| | - Manickam Sundarapandi
- Advanced Photonics Research Institute, Gwangju Institute of Science and Technology, Gwangju 61005, South Korea
| | - Balasubramaniem Ashokkumar
- Department of Genetic Engineering, School of Biotechnology, Madurai Kamaraj University, Madurai 625 021, Tamilnadu, India
| | - Vasantha Vairathevar Sivasamy
- Department of Natural Products Chemistry, School of Chemistry, Madurai Kamaraj University, Madurai 625 021, Tamilnadu, India.
| |
Collapse
|
6
|
Na'imah S, Apsari R, Masruroh, Yasin M, Wadi Harun S. Highly sensitive detection of low-concentration sodium chloride solutions based on a gold-coated prism in Kretschmann setup. Heliyon 2024; 10:e32349. [PMID: 38975194 PMCID: PMC11225726 DOI: 10.1016/j.heliyon.2024.e32349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Revised: 05/27/2024] [Accepted: 06/03/2024] [Indexed: 07/09/2024] Open
Abstract
A gold-coated Kretschmann setup has been constructed and explored as a surface plasmon resonance (SPR) platform, specifically tailored for the detection of low-concentration sodium chloride (NaCl) solutions. The setup employs a BK7 prism coated with a 50 nm gold layer, serving as a plasmonic layer, to induce resonance. This resonance arises from the interplay between light waves and free electrons propagating at the interface of two media. The experimental findings reveal a notable resonance angle shift of 10° when the NaCl concentration is varied from 0 to 2.5 %. Furthermore, angle interrogation provides insightful details about the sensor's response to changes in the refractive index, showcasing a commendable sensitivity of 2400°/RIU, a high level of linearity at 0.9771, and an impressive resolution of 0.217 %. The demonstrated capabilities of this sensor underscore its potential for widespread applications, particularly in the monitoring of salt concentration across diverse domains such as seawater analysis, food processing, and fermentation processes. The robust performance and precision of this proposed sensor position it as a valuable tool with promising prospects for addressing the needs of various industries dependent on accurate salt concentration measurements.
Collapse
Affiliation(s)
- Syahidatun Na'imah
- Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Brawijaya, Malang, 65145, Indonesia
| | - Retna Apsari
- Department of Physics, Faculty of Science and Technology, Universitas Airlangga, Surabaya, 60115, Indonesia
| | - Masruroh
- Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Brawijaya, Malang, 65145, Indonesia
| | - M. Yasin
- Department of Physics, Faculty of Science and Technology, Universitas Airlangga, Surabaya, 60115, Indonesia
| | - Sulaiman Wadi Harun
- Department of Electrical Engineering, Faculty of Engineering, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| |
Collapse
|
7
|
Mustaffa SN, Md Yatim N, Abdul Rashid AR, Md Yatim N, Pithaih V, Sha'ari NS, Muhammad AR, Abdul Rahman A, Jamil NA, Menon PS. Visible and angular interrogation of Kretschmann-based SPR using hybrid Au-ZnO optical sensor for hyperuricemia detection. Heliyon 2023; 9:e22926. [PMID: 38125452 PMCID: PMC10731088 DOI: 10.1016/j.heliyon.2023.e22926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 11/21/2023] [Accepted: 11/22/2023] [Indexed: 12/23/2023] Open
Abstract
Uric acid is a waste product of the human body where high levels of it or hyperuricemia can lead to gout, kidney disease and other health issues. In this paper, Finite Difference Time Doman (FDTD) simulation method was used to develop a plasmonic optical sensor to detect uric acid with molarity ranging from 0 to 3.0 mM. A hybrid layer of gold-zinc oxide (Au-ZnO) was used in this Kretschmann-based Surface Plasmon Resonance (K-SPR) technique with angular interrogation at 670 nm and 785 nm visible optical wavelengths. The purpose of this study is to observe the ability of the hybrid material as a sensing performance enhancer for differentiating between healthy and unhealthy uric acid levels based on the refractive index values from previous study. Upon exposure to 670 nm wavelength, the average sensitivity of this sensor was found to be 0.028°/mM with a linearity of 98.67 % and Q-factor value of 0.0053 mM - 1 . While at 785 nm, the average sensitivity is equal to 0.0193°/mM with slightly lower linearity at 94.46 % and Q-factor value of 0.0076 mM - 1 . The results have proven the ability of hybrid material Au-ZnO as a sensing performance enhancer for detecting uric acid when compared with bare Au and can be further explored in experimental work.
Collapse
Affiliation(s)
- Siti Nasuha Mustaffa
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| | - Nadhrah Md Yatim
- Faculty of Science and Technology, Universiti Sains Islam Malaysia (USIM), Bandar Baharu Nilai, 71800, Nilai, Negeri Sembilan, Malaysia
| | - Affa Rozana Abdul Rashid
- Faculty of Science and Technology, Universiti Sains Islam Malaysia (USIM), Bandar Baharu Nilai, 71800, Nilai, Negeri Sembilan, Malaysia
| | - Nadrah Md Yatim
- Faculty of Science and Technology, Universiti Sains Islam Malaysia (USIM), Bandar Baharu Nilai, 71800, Nilai, Negeri Sembilan, Malaysia
| | - Vatsala Pithaih
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| | - Nur Shahirah Sha'ari
- Faculty of Science and Technology, Universiti Sains Islam Malaysia (USIM), Bandar Baharu Nilai, 71800, Nilai, Negeri Sembilan, Malaysia
| | - Ahmad Razif Muhammad
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| | - Azaham Abdul Rahman
- Kulim Hi-Tech Pte Ltd, No.1, Jalan Bukit Hijau 26/24, Section 26, 40400, Shah Alam, Selangor, Malaysia
| | - Nur Akmar Jamil
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| | - P. Susthitha Menon
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| |
Collapse
|
8
|
He C, Li Y, Yang Y, Fan H, Li D, Han X. Sensitive Aluminum SPR Sensors Prepared by Thermal Evaporation Deposition. ACS OMEGA 2023; 8:43188-43196. [PMID: 38024768 PMCID: PMC10652738 DOI: 10.1021/acsomega.3c06855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/10/2023] [Accepted: 10/17/2023] [Indexed: 12/01/2023]
Abstract
We used straightforward thermal evaporation deposition to form thin Al films on fused silica slides as surface plasmon resonance (SPR) sensors in the blue visible region. Compared to other studies, we achieved high-quality Al SPR sensors with a low vacuum level at 7 × 10-4 Pa and a low deposition rate between 1.47 and 3.41 nm/s. These Al films have an atomic-level surface roughness. With our recipe, the requirements for deposition conditions are relaxed, and the operation time is reduced remarkably. The experimental sensitivity of the bulk refractive index measurements using 405 nm probing light is as high as 149.9°/RIU. Compared with other studies, our blue visible Al SPR completes the Al SPR working frequency range from deep UV to near-infrared which is much broader than the working range of Au SPR sensors. The cost of Al material is cheap, and the deposition instrument is also economic and operation easy. Considering the compatibility with most of the nanofabrication procedures and stability from the native oxide layer, Al SPR sensors have a huge potential to replace Au SPR sensors as the new golden standard of SPR sensing technology.
Collapse
Affiliation(s)
| | | | - Yuxiang Yang
- School of Optoelectrical
Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, China
| | - Huaikun Fan
- School of Optoelectrical
Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, China
| | - Dawei Li
- School of Optoelectrical
Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, China
| | - Xue Han
- School of Optoelectrical
Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, China
| |
Collapse
|
9
|
Lin CW, Tsai YH, Peng YS, Yang JT, Lu YP, Chen MY, Tung CW. A Novel Salivary Sensor with Integrated Au Electrodes and Conductivity Meters for Screening of Diabetes. BIOSENSORS 2023; 13:702. [PMID: 37504101 PMCID: PMC10377178 DOI: 10.3390/bios13070702] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 06/26/2023] [Accepted: 06/29/2023] [Indexed: 07/29/2023]
Abstract
The rise in diabetes cases is a growing concern due to the aging of populations. This not only places a strain on healthcare systems but also creates serious public health problems. Traditional blood tests are currently used to check blood sugar levels, but they are invasive and can discourage patients from regularly monitoring their levels. We recently developed nano-sensing probes that integrate Au microelectrodes and conductivity meters, requiring only 50 μL of saliva for measurement. The usage of the co-planar design of coating-free Au electrodes makes the measurement more stable, precise, and easier. This study found a positive correlation between the participant's fasting blood sugar levels and salivary conductivity. We observed a diabetes prevalence of 11.6% among 395 adults under 65 years in this study, using the glycated hemoglobin > 6.5% definition. This study found significantly higher salivary conductivity in the diabetes group, and also a clear trend of increasing diabetes as conductivity levels rose. The prediction model, using salivary conductivity, age, and body mass index, performed well in diagnosing diabetes, with a ROC curve area of 0.75. The study participants were further divided into low and high groups based on salivary conductivity using the Youden index with a cutoff value of 5.987 ms/cm. Individuals with higher salivary conductivity had a 3.82 times greater risk of diabetes than those with lower levels, as determined by the odds ratio calculation. In conclusion, this portable sensing device for salivary conductivity has the potential to be a screening tool for detecting diabetes.
Collapse
Affiliation(s)
- Chen-Wei Lin
- Department of Medical Education, Chang Gung Memorial Hospital, Chiayi 61363, Taiwan
| | - Yuan-Hsiung Tsai
- Department of Diagnostic Radiology, Chang Gung Memorial Hospital, Chiayi 61363, Taiwan
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan
| | - Yun-Shing Peng
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan
- Division of Endocrinology and Metabolism, Department of Internal Medicine, Chang Gung Memorial Hospital, Chiayi 61363, Taiwan
| | - Jen-Tsung Yang
- College of Medicine, Chang Gung University, Taoyuan 33302, Taiwan
- Department of Neurosurgery, Chang Gung Memorial Hospital, Chiayi 61363, Taiwan
| | - Yen-Pei Lu
- National Applied Research Laboratories, Taiwan Instrument Research Institute, Hsinchu 30261, Taiwan
| | - Mei-Yen Chen
- Department of Nursing, Chang Gung University of Science and Technology, Chiayi 61363, Taiwan
| | - Chun-Wu Tung
- Department of Nephrology, Chang Gung Memorial Hospital, Chiayi 61363, Taiwan
- Chang Gung Medical Education Research Centre, Taoyuan 33302, Taiwan
- Department of Biochemical Science and Technology, National Chiayi University, Chiayi 61363, Taiwan
| |
Collapse
|
10
|
Kashyap R, Boro PR, Yasmin R, Nath J, Sonowal D, Doley R, Mondal B. Multiple protein-patterned surface plasmon resonance biochip for the detection of human immunoglobulin-G. JOURNAL OF BIOPHOTONICS 2023; 16:e202200263. [PMID: 36683194 DOI: 10.1002/jbio.202200263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 11/18/2022] [Accepted: 01/02/2023] [Indexed: 05/17/2023]
Abstract
A portable surface plasmon resonance (SPR) measurement prototype integrated with a multiple protein-patterned SPR biochip is introduced for label-free and selective detection of human immunoglobulin-G (H-IgG). The polyclonal anti-H-IgG antibodies derived from goat, rabbit, and mouse were immobilized through polydimethylsiloxane (PDMS) microchannels to fabricate the patterned SPR biochip. The PDMS surface was functionalized using 3-aminopropyltrimethoxysilane and bonded to carbodiimide-activated gold substrates to construct irreversibly bonded hydrophilic microfluidic chip at room temperature. For SPR measurement, a custom-made system is developed with a high angular scanning accuracy of 0.005° and a wide scanning range of 30°-80° that avoids the conventional requirement of expensive goniometric stages and detector arrays. The SPR biochip immobilized with 750 μg/mL goat anti-H-IgG demonstrated detection of H-IgG with a detection limits of 15 μg/mL, and linear response through a wide concentration range (15-225 μg/mL) of high coefficient of determination (R2 = 0.99661). The selectivity of the sensor was investigated by exposing them to two different non-specific targets (bovine serum albumin and polyvalent antivenom). The results indicate negligible sensor response towards nonspecific targets (0.25° for 30 μg/mL bovine serum albumin (BSA) and 0.25° for 30 μg/mL polyvalent antivenom) in comparison to H-IgG (1.5° for 30 μg/mL).
Collapse
Affiliation(s)
- Ritayan Kashyap
- Department of Electronics and Communication Engineering, Tezpur University, Tezpur, Assam, India
| | - Pearleshwari Rani Boro
- Department of Electronics and Communication Engineering, Tezpur University, Tezpur, Assam, India
| | - Rafika Yasmin
- Department of Molecular Biology and Biotechnology, Tezpur University, Tezpur, Assam, India
| | - Jugabrat Nath
- Department of Electronics and Communication Engineering, Tezpur University, Tezpur, Assam, India
| | - Durlav Sonowal
- Department of Electronics and Communication Engineering, Tezpur University, Tezpur, Assam, India
| | - Robin Doley
- Department of Molecular Biology and Biotechnology, Tezpur University, Tezpur, Assam, India
| | - Biplob Mondal
- Department of Electronics and Communication Engineering, Tezpur University, Tezpur, Assam, India
| |
Collapse
|
11
|
Tian F, de Carvalho LFDCES, Casey A, Nogueira MS, Byrne HJ. Surface-Enhanced Raman Analysis of Uric Acid and Hypoxanthine Analysis in Fractionated Bodily Fluids. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1216. [PMID: 37049309 PMCID: PMC10097234 DOI: 10.3390/nano13071216] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 03/26/2023] [Accepted: 03/27/2023] [Indexed: 06/19/2023]
Abstract
In recent years, the disease burden of hyperuricemia has been increasing, especially in high-income countries and the economically developing world with a Western lifestyle. Abnormal levels of uric acid and hypoxanthine are associated with many diseases, and therefore, to demonstrate improved methods of uric acid and hypoxanthine detection, three different bodily fluids were analysed using surface-enhanced Raman spectroscopy (SERS) and high-performance liquid chromatography (HPLC). Gold nanostar suspensions were mixed with series dilutions of uric acid and hypoxanthine, 3 kDa centrifugally filtered human blood serum, urine and saliva. The results show that gold nanostars enable the quantitative detection of the concentration of uric acid and hypoxanthine in the range 5-50 μg/mL and 50-250 ng/mL, respectively. The peak areas of HPLC and maximum peak intensity of SERS have strongly correlated, notably with the peaks of uric acid and hypoxanthine at 1000 and 640 cm-1, respectively. The r2 is 0.975 and 0.959 for uric acid and hypoxanthine, respectively. Each of the three body fluids has a number of spectral features in common with uric acid and hypoxanthine. The large overlap of the spectral bands of the SERS of uric acid against three body fluids at spectra peaks were at 442, 712, 802, 1000, 1086, 1206, 1343, 1436 and 1560 cm-1. The features at 560, 640, 803, 1206, 1290 and 1620 cm-1 from hypoxanthine were common to serum, saliva and urine. There is no statistical difference between HPLC and SERS for determination of the concentration of uric acid and hypoxanthine (p > 0.05). For clinical applications, 3 kDa centrifugal filtration followed by SERS can be used for uric acid and hypoxanthine screening is, which can be used to reveal the subtle abnormalities enhancing the great potential of vibrational spectroscopy as an analytical tool. Our work supports the hypnosis that it is possible to obtain the specific concentration of uric acid and hypoxanthine by comparing the SER signals of serum, saliva and urine. In the future, the analysis of other biofluids can be employed to detect biomarkers for the diagnosis of systemic pathologies.
Collapse
Affiliation(s)
- Furong Tian
- FOCAS Research Institute, Technological University Dublin Camden Row, D08CKP1 Dublin, Ireland; (A.C.)
| | - Luis Felipe das Chagas e Silva de Carvalho
- FOCAS Research Institute, Technological University Dublin Camden Row, D08CKP1 Dublin, Ireland; (A.C.)
- Centro Universitario Braz Cubas, Mogi das Cruzes 08773-380, Brazil
- Universidade de Taubate, Taubate 12080-000, Brazil
| | - Alan Casey
- FOCAS Research Institute, Technological University Dublin Camden Row, D08CKP1 Dublin, Ireland; (A.C.)
| | - Marcelo Saito Nogueira
- Tyndall National Institute, Lee Maltings Complex, Dyke Parade, T12R5CP Cork, Ireland;
- Department of Physics, University College Cork, College Road, T12K8AF Cork, Ireland
| | - Hugh J. Byrne
- FOCAS Research Institute, Technological University Dublin Camden Row, D08CKP1 Dublin, Ireland; (A.C.)
| |
Collapse
|
12
|
SPR-Based Sensor for the Early Detection or Monitoring of Kidney Problems. Int J Biomater 2022; 2022:9135172. [PMID: 35755268 PMCID: PMC9225913 DOI: 10.1155/2022/9135172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 05/12/2022] [Accepted: 05/19/2022] [Indexed: 11/17/2022] Open
Abstract
SPR-based technology has emerged as one of the most versatile optical tools for analyzing the binding mechanism of molecular interaction due to its inherent advantages in sensing applications, such as real-time, label-free, and high sensitivity characteristics. SPR is widely used in various fields, including healthcare, environmental management, and food-borne illness analysis. Meanwhile, kidney disease has grown to be one of the world's most serious public health problems in recent decades, resulting in physical degeneration and even death. As a result, several studies have published their findings regarding developing of reliable sensor technology based on the SPR phenomenon. However, an integrated and comprehensive discussion regarding the application of SPR-based sensors for detecting of kidney disease has not yet been found. Therefore, this review will discuss the recent advancements in the development of SPR-based sensors for monitoring kidney-related diseases. Numerous SPR configurations will be discussed, including Kretschmann, Otto, optical fiber-based SPR, and LSPR, which are all used to detect analytes associated with kidney disease, including urea, creatinine, glucose, uric acid, and dopamine. This review aims to show the broad application of SPR sensors which encouraged the development of SPR sensors for kidney problems monitoring.
Collapse
|
13
|
Banerjee J, Mandal S, Pradhan M. Polarization-Multiplexed Incoherent Broadband Surface Plasmon Resonance: A New Analytical Strategy for Plasmonic Sensing. Anal Chem 2022; 94:6689-6694. [PMID: 35476390 DOI: 10.1021/acs.analchem.1c05252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Surface plasmon resonance (SPR) is an interfacial phenomenon, and the plasmonic sensors are based on the optical excitation of the collective oscillations of free electrons at a metal-dielectric interface. Here, we present the new development of an incoherent broadband (IBB)-SPR probe combining the wavelength interrogation technique with polarization-multiplexing (PM). The performance characteristics of the so-called PMIBB-SPR strategy was validated for the detection of nonenzymatic aqueous urea samples as a representative example for plasmonic sensing with an excellent wavelength and phase sensitivities of 0.1363 nm/mM and 10.34597 mM/deg, respectively. We further explored the missing link between plasmonic polariton resonance (PPR) and polarization modulation via the measurements of the Stokes parameters of the reflected light. This deepens our understanding of the fundamentals of polarization-multiplexed SPR phenomenon at the interface. This study thus paves the way to develop a new-generation analytical technique with the aim of tracking various real-time chemical and biological molecular interactions occurring at the interfaces.
Collapse
Affiliation(s)
- Jayeta Banerjee
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Salt Lake, JD Block, Sector III, Kolkata 700106, India
| | - Sudip Mandal
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Salt Lake, JD Block, Sector III, Kolkata 700106, India
| | - Manik Pradhan
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Salt Lake, JD Block, Sector III, Kolkata 700106, India
| |
Collapse
|
14
|
Ahmad Khushaini MA, Azeman NH, Mat Salleh M, Tg Abdul Aziz TH, A Bakar AA, De La Rue RM, Md Zain AR. Exploiting a strong coupling regime of organic pentamer surface plasmon resonance based on the Otto configuration for creatinine detection. OPTICS EXPRESS 2022; 30:14478-14491. [PMID: 35473189 DOI: 10.1364/oe.448947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 02/11/2022] [Indexed: 06/14/2023]
Abstract
The sandwiched material-analyte layer in the surface plasmon resonance (SPR)-Otto configuration emulates an optical cavity and, coupled with large optical nonlinearity material, the rate of light escaping from the system is reduced, allowing the formation of a strong coupling regime. Here, we report an organic pentamer SPR sensor using the Otto configuration to induce a strong coupling regime for creatinine detection. Prior to that, the SPR sensor chip was modified with an organic pentamer, 1,4-bis[2-(5-thiophene-2-yl)-1-benzothiopene]-2,5-dioctyloxybenzene (BOBzBT2). To improve the experimental calibration curve, a normalisation approach based on the strong coupling-induced second dip was also developed. By using this procedure, the performance of the sensor improved to 0.11 mg/dL and 0.36 mg/dL for the detection and quantification limits, respectively.
Collapse
|
15
|
Li M, Singh R, Marques C, Zhang B, Kumar S. 2D material assisted SMF-MCF-MMF-SMF based LSPR sensor for creatinine detection. OPTICS EXPRESS 2021; 29:38150-38167. [PMID: 34808874 DOI: 10.1364/oe.445555] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
The purpose of this work is to propose a simple, portable, and sensitive biosensor structure based on singlemode fiber-multicore fiber-multimode fiber-singlemode fiber (SMF-MCF-MMF-SMF) for the detection of creatinine in the human body. Chemical etching has been used to modify the diameter of the sensing probe to approximately 90 μm in order to generate strong evanescent waves (EWs). The sensor probe is functionalized with graphene oxide (GO), gold nanoparticles (AuNPs), molybdenum disulfide nanoparticles (MoS2-NPs), and creatininase (CA) enzyme. The concentration of creatinine is determined using fiber optic localized surface plasmon resonance (LSPR). While EWs are used to enhance the LSPR effect of AuNPs, two-dimensional (2D) materials (GO and MoS2-NPs) are used to increase biocompatibility, and CA is used to increase probe specificity. Additionally, HR-TEM and UV-visible spectroscopy are used to characterize and measure the nanoparticle (NP) morphology and absorption spectrum, respectively. SEM is used to characterize the NPs immobilized on the surface of the fiber probe. The sensor probe's reusability, reproducibility, stability, selectivity, and pH test results are also tested to verify the sensor performance. The sensitivity of proposed sensor is 0.0025 nm/μM, has a standard deviation of 0.107, and has a limit of detection of 128.4 μM over a linear detection range of 0 - 2000 μM.
Collapse
|
16
|
Ravindran N, Kumar S, M Y, S R, C A M, Thirunavookarasu S N, C K S. Recent advances in Surface Plasmon Resonance (SPR) biosensors for food analysis: a review. Crit Rev Food Sci Nutr 2021; 63:1055-1077. [PMID: 34328048 DOI: 10.1080/10408398.2021.1958745] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Food safety is the prime area of concern that builds trust. With the prevailing advancements, it has become facile to ensure safety in almost all aspects. Technology has grown from tedious lab techniques to modern chromatographic techniques and immunoassays, progressed with more precise and rapid sensing through the advent of Biosensors. Biosensors provide an automated technology by presenting superfast, nondestructive and cost-effective detection in food analysis. SPR biosensor is an optical biosensor known for its versatility and has wider applications in food testing and analysis. It has an optical system for excitation and interrogation of surface plasmons, and a biomolecular recognition element to detect and seize the target analyte present in a sample. The optical signal detects the binding analyte, on the recognition element, which results in a change in refractive index at the surface and modifies the surface plasmons' propagation constant. SPR aids in label-free detection of various components such as adulterants, antibiotics, biomolecules, genetically modified foods, pesticides, insecticides, herbicides, microorganisms and microbial toxins in food and assures safety. The distinct advancements of SPR in food analysis have been found and discussed. The review also provides knowledge on the advantages and the key challenges encountered by SPR.
Collapse
Affiliation(s)
- Nevetha Ravindran
- Department of Food Engineering, Indian Institute of Food Processing Technology, Thanjavur, India
| | - Sandhya Kumar
- Department of Food Engineering, Indian Institute of Food Processing Technology, Thanjavur, India
| | - Yashini M
- Department of Food Engineering, Indian Institute of Food Processing Technology, Thanjavur, India
| | - Rajeshwari S
- Department of Food Engineering, Indian Institute of Food Processing Technology, Thanjavur, India
| | - Mamathi C A
- Department of Food Engineering, Indian Institute of Food Processing Technology, Thanjavur, India
| | | | - Sunil C K
- Department of Food Engineering, Indian Institute of Food Processing Technology, Thanjavur, India
| |
Collapse
|
17
|
Label-Free Creatinine Optical Sensing Using Molecularly Imprinted Titanium Dioxide-Polycarboxylic Acid Hybrid Thin Films: A Preliminary Study for Urine Sample Analysis. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9070185] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Creatinine (CR) is a representative metabolic byproduct of muscles, and its sensitive and selective detection has become critical in the diagnosis of kidney diseases. In this study, poly(acrylic acid) (PAA)-assisted molecularly imprinted (MI) TiO2 nanothin films fabricated via liquid phase deposition (LPD) were employed for CR detection. The molecular recognition properties of the fabricated films were evaluated using fiber optic long period grating (LPG) and quartz crystal microbalance sensors. Imprinting effects were examined compared with nonimprinted (NI) pure TiO2 and PAA-assisted TiO2 films fabricated similarly without a template. In addition, the surface modification of the optical fiber section containing the LPG with a mesoporous base coating of silica nanoparticles, which was conducted before LPD-based TiO2 film deposition, contributed to the improvement of the sensitivity of the MI LPG sensor. The sensitivity and selectivity of LPGs coated with MI films were tested using CR solutions dissolved in different pH waters and artificial urine (near pH 7). The CR binding constants of the MI and NI films, which were calculated from the Benesi–Hildebrand plots of the wavelength shifts of the second LPG band recorded in water at pH 4.6, were estimated to be 67 and 7.8 M–1, respectively, showing an almost ninefold higher sensitivity in the MI film. The mechanism of the interaction between the template and the TiO2 matrix and the film composition was investigated via ultraviolet–visible and attenuated total reflectance Fourier-transform infrared spectroscopy along with X-ray photoelectron spectroscopy analysis. In addition, morphological studies using a scanning electron microscope and atomic force microscope were conducted. The proposed system has the potential for practical use to determine CR levels in urine samples. This LPG-based label-free CR biosensor is innovative and expected to be a new tool to identify complex biomolecules in terms of its easy fabrication and simplicity in methodology.
Collapse
|
18
|
Sensitivity Analysis of Single- and Bimetallic Surface Plasmon Resonance Biosensors. SENSORS 2021; 21:s21134348. [PMID: 34202104 PMCID: PMC8271734 DOI: 10.3390/s21134348] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 06/19/2021] [Accepted: 06/21/2021] [Indexed: 12/16/2022]
Abstract
Comparative analysis of the sensitivity of two surface plasmon resonance (SPR) biosensors was conducted on a single-metallic Au sensor and bimetallic Ag–Au sensor, using a cathepsin S sensor as an example. Numerically modeled resonance curves of Au and Ag–Au layers, with parameters verified by the results of experimental reflectance measurement of real-life systems, were used for the analysis of these sensors. Mutual relationships were determined between ∂Y/∂n components of sensitivity of the Y signal in the SPR measurement to change the refractive index n of the near-surface sensing layer and ∂n/∂c sensitivity of refractive index n to change the analyte’s concentration, c, for both types of sensors. Obtained results were related to experimentally determined calibration curves of both sensors. A characteristic feature arising from the comparison of calibration curves is the similar level of Au and Ag–Au biosensors’ sensitivity in the linear range, where the signal of the AgAu sensor is at a level several times greater. It was shown that the influence of sensing surface morphology on the ∂n/∂c sensitivity component had to be incorporated to explain the features of calibration curves of sensors. The shape of the sensory surface relief was proposed to increase the sensor sensitivity at low analyte concentrations.
Collapse
|
19
|
Akib TBA, Mou SF, Rahman MM, Rana MM, Islam MR, Mehedi IM, Mahmud MAP, Kouzani AZ. Design and Numerical Analysis of a Graphene-Coated SPR Biosensor for Rapid Detection of the Novel Coronavirus. SENSORS (BASEL, SWITZERLAND) 2021; 21:3491. [PMID: 34067769 PMCID: PMC8156410 DOI: 10.3390/s21103491] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 04/28/2021] [Accepted: 05/11/2021] [Indexed: 02/07/2023]
Abstract
In this paper, a highly sensitive graphene-based multiple-layer (BK7/Au/PtSe2/Graphene) coated surface plasmon resonance (SPR) biosensor is proposed for the rapid detection of the novel Coronavirus (COVID-19). The proposed sensor was modeled on the basis of the total internal reflection (TIR) technique for real-time detection of ligand-analyte immobilization in the sensing region. The refractive index (RI) of the sensing region is changed due to the interaction of different concentrations of the ligand-analyte, thus impacting surface plasmon polaritons (SPPs) excitation of the multi-layer sensor interface. The performance of the proposed sensor was numerically investigated by using the transfer matrix method (TMM) and the finite-difference time-domain (FDTD) method. The proposed SPR biosensor provides fast and accurate early-stage diagnosis of the COVID-19 virus, which is crucial in limiting the spread of the pandemic. In addition, the performance of the proposed sensor was investigated numerically with different ligand-analytes: (i) the monoclonal antibodies (mAbs) as ligand and the COVID-19 virus spike receptor-binding domain (RBD) as analyte, (ii) the virus spike RBD as ligand and the virus anti-spike protein (IgM, IgG) as analyte and (iii) the specific probe as ligand and the COVID-19 virus single-standard ribonucleic acid (RNA) as analyte. After the investigation, the sensitivity of the proposed sensor was found to provide 183.33°/refractive index unit (RIU) in SPR angle (θSPR) and 833.33THz/RIU in SPR frequency (SPRF) for detection of the COVID-19 virus spike RBD; the sensitivity obtained 153.85°/RIU in SPR angle and 726.50THz/RIU in SPRF for detection of the anti-spike protein, and finally, the sensitivity obtained 140.35°/RIU in SPR angle and 500THz/RIU in SPRF for detection of viral RNA. It was observed that whole virus spike RBD detection sensitivity is higher than that of the other two detection processes. Highly sensitive two-dimensional (2D) materials were used to achieve significant enhancement in the Goos-Hänchen (GH) shift detection sensitivity and plasmonic properties of the conventional SPR sensor. The proposed sensor successfully senses the COVID-19 virus and offers additional (1 + 0.55) × L times sensitivity owing to the added graphene layers. Besides, the performance of the proposed sensor was analyzed based on detection accuracy (DA), the figure of merit (FOM), signal-noise ratio (SNR), and quality factor (QF). Based on its performance analysis, it is expected that the proposed sensor may reduce lengthy procedures, false positive results, and clinical costs, compared to traditional sensors. The performance of the proposed sensor model was checked using the TMM algorithm and validated by the FDTD technique.
Collapse
Affiliation(s)
- Tarik Bin Abdul Akib
- Department of Electrical and Electronic Engineering, Rajshahi University of Engineering and Technology, Rajshahi 6204, Bangladesh; (T.B.A.A.); (S.F.M.); (M.M.R.); (M.M.R.)
| | - Samia Ferdous Mou
- Department of Electrical and Electronic Engineering, Rajshahi University of Engineering and Technology, Rajshahi 6204, Bangladesh; (T.B.A.A.); (S.F.M.); (M.M.R.); (M.M.R.)
| | - Md. Motiur Rahman
- Department of Electrical and Electronic Engineering, Rajshahi University of Engineering and Technology, Rajshahi 6204, Bangladesh; (T.B.A.A.); (S.F.M.); (M.M.R.); (M.M.R.)
| | - Md. Masud Rana
- Department of Electrical and Electronic Engineering, Rajshahi University of Engineering and Technology, Rajshahi 6204, Bangladesh; (T.B.A.A.); (S.F.M.); (M.M.R.); (M.M.R.)
| | - Md. Rabiul Islam
- Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW 2522, Australia;
| | - Ibrahim M. Mehedi
- Department of Electrical and Computer Engineering (ECE) and Center of Excellence in Intelligent Engineering Systems (CEIES), King Abdulaziz University, Jeddah 21589, Saudi Arabia;
| | | | - Abbas Z. Kouzani
- School of Engineering, Deakin University, Geelong, VIC 3216, Australia;
| |
Collapse
|
20
|
Fatema KN, Jung CH, Liu Y, Sagadevan S, Cho KY, Oh WC. New Design of Active Material Based on YInWO4-G-SiO2 for a Urea Sensor and High Performance for Nonenzymatic Electrical Sensitivity. ACS Biomater Sci Eng 2020; 6:6981-6994. [DOI: 10.1021/acsbiomaterials.0c00423] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Kamrun Nahar Fatema
- Department of Advanced Materials Science & Engineering, Hanseo University, Seosan-si, Chungnam 356-706, Korea
| | - Chong-Hun Jung
- Decommissioning Technology Research Division, Korea Atomic Energy Research Institute, P.O. Box 105,
Yuseong, Daejeon 305-600, Korea
| | - Yin Liu
- College of Materials Science and Engineering, Anhui University of Science & Technology, Huainan 232001, P. R. China
| | - Suresh Sagadevan
- Nanotechnology & Catalysis Research Centre, University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Kwang Youn Cho
- Korea Institutes of Ceramic Engineering and Technology, Soho-ro, Jinju-Si, Gyeongsangnam-do 52851, South Korea
| | - Won-Chun Oh
- Department of Advanced Materials Science & Engineering, Hanseo University, Seosan-si, Chungnam 356-706, Korea
- College of Materials Science and Engineering, Anhui University of Science & Technology, Huainan 232001, P. R. China
| |
Collapse
|
21
|
Non-enzymatic electrochemical determination of creatinine using a novel screen-printed microcell. Talanta 2020; 207:120277. [DOI: 10.1016/j.talanta.2019.120277] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Revised: 08/13/2019] [Accepted: 08/16/2019] [Indexed: 01/30/2023]
|
22
|
A metal-organic zeolitic framework with immobilized urease for use in a tapered optical fiber urea biosensor. Mikrochim Acta 2019; 187:72. [DOI: 10.1007/s00604-019-4026-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Accepted: 11/09/2019] [Indexed: 12/13/2022]
|
23
|
Kumar P, Kamboj M, Jaiwal R, Pundir CS. Fabrication of an improved amperometric creatinine biosensor based on enzymes nanoparticles bound to Au electrode. Biomarkers 2019; 24:739-749. [PMID: 31617777 DOI: 10.1080/1354750x.2019.1682045] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
An improved amperometric creatinine biosensor was fabricated that dependent on covalent immobilisation of nanoparticles of creatininase (CANPs), creatinase (CINPs) and sarcosine oxidase (SOxNPs) onto gold electrode (AuE). The CANPs/CINPs/SOxNPs/AuE was characterised by scanning electron microscopy and cyclic voltammetry at various stages. The working electrode exhibited optimal response within 2 s at a potential of 0.6 V, against Ag/AgCl, pH 6.5 and 30 °C. A linear relationship was observed between creatinine concentration range, 0.1-200μM and biosensor response i.e. current in mA, under optimum conditions. Biosensor offered a low detection limit of 0.1 μM with long storage stability. Analytical recoveries of added creatinine in blood sera at 0.5 mM and at 1.0 mM concentrations, were 92.0% and 79.20% respectively. The precision i.e. within and between-batch coefficients of variation were 2.04% and 3.06% respectively. There was a good correlation (R2 = 0.99) between level of creatinine in sera, as calculated by the colorimetric method and present electrode. The CANPs/CINPs/SOxNPs/Au electrode was reused 200 times during the period of 180 days, with just 10% loss in its initial activity, while being stored at 4 °C, when not in use.HighlightsPrepared and characterised creatininase (CA), creatinase (CI) sarcosine oxidase (SOx) nanoparticles and immobilised them onto gold electrode (AuE) for fabrication of an improved amperometric creatinine biosensor.The biosensor displayed a limit of detection (LOD) of 0.1 μM with a linear working range of 0.1 μM-200 μM.The biosensor was evaluated and applied to measure elevated creatinine levels in sera from whom suffering from kidney and muscular disorders.The working electrode retained 90% of its initial activity, while being stored dry at 4 ˚C for 180 days.
Collapse
Affiliation(s)
- Parveen Kumar
- Department of Biochemistry, M.D. University, Rohtak, India
| | - Mohit Kamboj
- Department of Zoology, M.D. University, Rohtak, India
| | | | - C S Pundir
- Department of Biochemistry, M.D. University, Rohtak, India
| |
Collapse
|
24
|
Xia Y, Zhu C, Bian J, Li Y, Liu X, Liu Y. Highly Sensitive and Selective Colorimetric Detection of Creatinine Based on Synergistic Effect of PEG/Hg 2+-AuNPs. NANOMATERIALS 2019; 9:nano9101424. [PMID: 31597333 PMCID: PMC6835235 DOI: 10.3390/nano9101424] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 10/03/2019] [Accepted: 10/04/2019] [Indexed: 11/16/2022]
Abstract
A colorimetric sensor, based on the synergistic coordination effect on a gold nanoparticle (AuNP) platform has been developed for the determination of creatinine. The sensor selects citrate stabilized AuNPs as a platform, polyethylene glycol (PEG) as a decorator, and Hg2+ as a linkage to form a colorimetric probe system (PEG/Hg2−–AuNPs). By forming hydrogen bond between the oxygen-containing functional groups of PEG and citrate ions on the surface of AuNPs, this probe shows good stability. PEG coordinated with Hg2+ synergistically and specifically on the surface of dispersed AuNPs, and the existence of creatinine could induce the aggregation of AuNPs with a corresponding color change and an obvious absorption peak shift within 5 min. This PEG/Hg2+–AuNPs probe towards creatinine shows high sensitivity, and a good linear relationship (R2 = 0.9948) was obtained between A620–522 nm and creatinine concentration, which can achieve the quantitative calculations of creatinine. The limit of detection (LOD) of this PEG/Hg2+–AuNPs probe was estimated to be 9.68 nM, lower than that of many other reported methods. Importantly, the sensitive probe can be successfully applied in a urine simulating fluid sample and a bovine serum sample. The unique synergistic coordination sensing mechanism applied in the designation of this probe further improves its high selectivity and specificity for the detection of creatinine. Thus, the proposed probe may give new inspirations for colorimetric detection of creatinine and other biomolecules.
Collapse
Affiliation(s)
- Yunxia Xia
- School of Chemistry and Materials Science, Ludong University, Yantai 264025, Shandong, China.
| | - Chenxue Zhu
- School of Chemistry and Materials Science, Ludong University, Yantai 264025, Shandong, China.
| | - Jie Bian
- School of Chemistry and Materials Science, Ludong University, Yantai 264025, Shandong, China.
| | - Yuxi Li
- School of Chemistry and Materials Science, Ludong University, Yantai 264025, Shandong, China
| | - Xunyong Liu
- School of Chemistry and Materials Science, Ludong University, Yantai 264025, Shandong, China.
| | - Yi Liu
- School of Chemistry and Materials Science, Ludong University, Yantai 264025, Shandong, China.
| |
Collapse
|