1
|
Kushnir MM, Salihovic S, Bergquist J, Lind PM, Lind L. Environmental contaminants, sex hormones and SHBG in an elderly population. ENVIRONMENTAL RESEARCH 2024; 263:120054. [PMID: 39341538 DOI: 10.1016/j.envres.2024.120054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Revised: 09/12/2024] [Accepted: 09/22/2024] [Indexed: 10/01/2024]
Abstract
INTRODUCTION Effects of environmental contaminants (ECs) on endocrine systems have been reported, but few studies assessed associations between ECs and sex hormones (SH) in elderly. Aim of this study was to investigate whether blood concentrations of four classes of ECs were associated with SH concentrations in elderly. METHODS Samples from participants of the cross-sectional population-based Prospective Investigation of the Vasculature in Uppsala Seniors study (PIVUS, 70-year-old men and women, n = 1016) were analyzed using validated mass spectrometry-based methods for SH (testosterone (T), dihydrotestosterone (DHT), estrone and estradiol (E2)); 23 persistent organic pollutants (POPs); 8 perfluoroalkyl substances (PFAS); 4 phthalates and 11 metals. SH binding globulin (SHBG) was analyzed using immunoassay. The measured concentrations were normalized, and the values converted to a z-scale. Linear regression analyses were conducted to assess association between concentration of the SH, SHBG and E2/T (aromatase enzyme index, AEI) with the ECs. Multiple linear regression analyses were performed to model the relationships. RESULTS The strongest associations were observed with the polychlorinated biphenyls (PCBs). In men, the strongest associations with concentrations of SH and SHBG were seen for PCBs containing >5 chlorine, monoethyl phthalate (MEP), Ni and Cd; and in women, with PCBs, MEP, several of the PFAS, Cd, Co, and Ni. Difference in the effect of ECs on AEI between men and women were observed. Area under the ROC curve for the models predicting abnormal values of SH and SHBG >0.75 due to the effects of ECs was observed for T, DHT, and E2 in men, and for E2 and SHBG in women. CONCLUSIONS Results of this study suggest that in elderly subjects, concentrations of many ECs associated with concentrations of SH and SHBG, and AEI. Further studies are needed to confirm the findings and to assess effect of the pollutants on endocrine system function in elderly.
Collapse
Affiliation(s)
- Mark M Kushnir
- ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT, USA; Department of Pathology, University of Utah, Salt Lake City, UT, USA.
| | - Samira Salihovic
- School of Medical Sciences, Faculty of Medicine and Health, Örebro University, Sweden
| | - Jonas Bergquist
- Department of Pathology, University of Utah, Salt Lake City, UT, USA; Department of Chemistry, Analytical Chemistry, Uppsala University, Uppsala, Sweden
| | - P Monica Lind
- Department of Medical Sciences, Occupational and Environmental Medicine, Uppsala University, Uppsala, Sweden
| | - Lars Lind
- Department of Medical Sciences, Cardiovascular Epidemiology, Uppsala University, Uppsala, Sweden
| |
Collapse
|
2
|
Sdougkou K, Papazian S, Bonnefille B, Xie H, Edfors F, Fagerberg L, Uhlén M, Bergström G, Martin LJ, Martin JW. Longitudinal Exposomics in a Multiomic Wellness Cohort Reveals Distinctive and Dynamic Environmental Chemical Mixtures in Blood. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:16302-16315. [PMID: 39236221 PMCID: PMC11411717 DOI: 10.1021/acs.est.4c05235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/07/2024]
Abstract
Chemical exposomes can now be comprehensively measured in human blood, but knowledge of their variability and longitudinal stability is required for robust application in cohort studies. Here, we applied high-resolution chemical exposomics to plasma of 46 adults, each sampled 6 times over 2 years in a multiomic cohort, resulting in 276 individual exposomes. In addition to quantitative analysis of 83 priority target analytes, we discovered and semiquantified substances that have rarely or never been reported in humans, including personal care products, pesticide transformation products, and polymer additives. Hierarchical cluster analysis for 519 confidently annotated substances revealed unique and distinctive coexposures, including clustered pesticides, poly(ethylene glycols), chlorinated phenols, or natural substances from tea and coffee; interactive heatmaps were publicly deposited to support open exploration of the complex (meta)data. Intraclass correlation coefficients (ICC) for all annotated substances demonstrated the relatively low stability of the exposome compared to that of proteome, microbiome, and endogenous small molecules. Implications are that the chemical exposome must be measured more frequently than other omics in longitudinal studies and four longitudinal exposure types are defined that can be considered in study design. In this small cohort, mixed-effect models nevertheless revealed significant associations between testosterone and perfluoroalkyl substances, demonstrating great potential for longitudinal exposomics in precision health research.
Collapse
Affiliation(s)
- Kalliroi Sdougkou
- Department of Environmental Science, Stockholm University, Stockholm 106 91, Sweden
| | - Stefano Papazian
- Department of Environmental Science, Stockholm University, Stockholm 106 91, Sweden
- National Facility for Exposomics, Metabolomics Platform, Science for Life Laboratory, Stockholm University, Solna 171 65, Sweden
| | - Bénilde Bonnefille
- Department of Environmental Science, Stockholm University, Stockholm 106 91, Sweden
- National Facility for Exposomics, Metabolomics Platform, Science for Life Laboratory, Stockholm University, Solna 171 65, Sweden
| | - Hongyu Xie
- Department of Environmental Science, Stockholm University, Stockholm 106 91, Sweden
| | - Fredrik Edfors
- Department of Protein Science, Science for Life Laboratory, KTH-Royal Institute of Technology, Stockholm 100 44, Sweden
| | - Linn Fagerberg
- Department of Protein Science, Science for Life Laboratory, KTH-Royal Institute of Technology, Stockholm 100 44, Sweden
| | - Mathias Uhlén
- Department of Protein Science, Science for Life Laboratory, KTH-Royal Institute of Technology, Stockholm 100 44, Sweden
| | - Göran Bergström
- Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg 40530, Sweden
- Department of Clinical Physiology, Sahlgrenska University Hospital, Region Västra Götaland, Gothenburg 413 45, Sweden
| | | | - Jonathan W Martin
- Department of Environmental Science, Stockholm University, Stockholm 106 91, Sweden
- National Facility for Exposomics, Metabolomics Platform, Science for Life Laboratory, Stockholm University, Solna 171 65, Sweden
| |
Collapse
|
3
|
Cho SE, Han J, Park JH, Park E, Kim GY, Lee JH, Yi A, Lee SG, Lee EH, Yun YM. Clinical Usefulness of Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Method for Low Serum Testosterone Measurement. Ann Lab Med 2023; 43:19-28. [PMID: 36045053 PMCID: PMC9467846 DOI: 10.3343/alm.2023.43.1.19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 05/27/2022] [Accepted: 08/03/2022] [Indexed: 12/27/2022] Open
Abstract
Background Mass spectrometry methods exhibit higher accuracy and lower variability than immunoassays at low testosterone concentrations. We developed and validated an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for quantifying serum total testosterone. Methods We used an ExionLC UPLC (Sciex, Framingham, MA, USA) system and a Sciex Triple Quad 6500+ (Sciex) MS/MS system in electrospray ionization and positive ion modes with multiple reaction monitoring transitions to evaluate precision, accuracy, linearity, lower limit of quantitation (LLOQ), carryover, ion suppression, stability, and reference intervals. For method comparison, we measured serum testosterone concentrations using this method in 40 subjects whose testosterone concentrations ranged from 0.14 to 55.48 nmol/L as determined using the Architect i2000 immunoassay (Abbott Diagnostics, Abbott Park, IL, USA) and in an additional 160 sera with testosterone concentrations <1.67 nmol/L. Results The intra- and inter-run precision CVs were <2.81%, and the accuracy bias values were <3.85%, which were all acceptable. The verified linear interval was 0.03-180.84 nmol/L; the LLOQ was 0.03 nmol/L. No significant carryover and ion suppression were observed. The testosterone in serum was stable at 4°C, at -20°C, and after three freeze-thaw cycles. The reference intervals were successfully verified. The correlation was good at testosterone concentrations of 0.14-55.48 nmol/L; however, the Architect assay showed positive percent bias at concentrations <1.67 nmol/L. Conclusions The UPLC-MS/MS assay shows acceptable performance, with a lower LLOQ than the immunoassay. This method will enable the quantitation of low testosterone concentrations.
Collapse
Affiliation(s)
- Sung-Eun Cho
- Department of Laboratory Medicine, GCLabs, Yongin, Korea
| | - Jungsun Han
- Department of Laboratory Medicine, GCLabs, Yongin, Korea
| | - Ju-Hee Park
- Department of Laboratory Medicine, GCLabs, Yongin, Korea
| | - Euna Park
- Department of Laboratory Medicine, GCLabs, Yongin, Korea
| | - Geun Young Kim
- Department of Laboratory Medicine, GCLabs, Yongin, Korea
| | - Jun Hyung Lee
- Department of Laboratory Medicine, GCLabs, Yongin, Korea
| | - Ahram Yi
- Department of Laboratory Medicine, GCLabs, Yongin, Korea
| | - Sang Gon Lee
- Department of Laboratory Medicine, GCLabs, Yongin, Korea
| | - Eun Hee Lee
- Department of Laboratory Medicine, GCLabs, Yongin, Korea
| | - Yeo-Min Yun
- Department of Laboratory Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
| |
Collapse
|
4
|
Tang L, Swezey RR, Green CE, Lee MS, Bunin DI, Parman T. A tandem liquid chromatography and tandem mass spectrometry (LC/LC-MS/MS) technique to separate and quantify steroid isomers 11β-methyl-19-nortestosterone and testosterone. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1193:123165. [PMID: 35158319 PMCID: PMC9360186 DOI: 10.1016/j.jchromb.2022.123165] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 01/07/2022] [Accepted: 02/07/2022] [Indexed: 10/19/2022]
Abstract
Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) has become a mainstay analytical technique in pharmaceutical research and development and clinical diagnosis due to several advantages including excellent selectivity, specificity, and high sensitivity. LC-MS/MS has become the method of choice for steroids analysis due to its fast analytical time and improved specificity yet has a challenge in the separation and measurement of isomers with the same product ions. Here we describe a high-sensitivity LC/LC-MS/MS method that combines chiral chromatography and reverse-phase chromatography (LC/LC) along with MS/MS to rapidly separate and quantify steroid isomers of 11ß-methyl-19-nortestosterone (11ß-MNT) and endogenous testosterone in serum.
Collapse
Affiliation(s)
| | | | | | - Min S Lee
- National Institute of Child Health and Human Development, Bethesda, MD, USA
| | | | | |
Collapse
|
5
|
Rappold BA. Review of the Use of Liquid Chromatography-Tandem Mass Spectrometry in Clinical Laboratories: Part I-Development. Ann Lab Med 2022; 42:121-140. [PMID: 34635606 PMCID: PMC8548246 DOI: 10.3343/alm.2022.42.2.121] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 06/25/2021] [Accepted: 09/28/2021] [Indexed: 11/19/2022] Open
Abstract
The process of method development for a diagnostic assay based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) involves several disparate technologies and specialties. Additionally, method development details are typically not disclosed in journal publications. Method developers may need to search widely for pertinent information on their assay(s). This review summarizes the current practices and procedures in method development. Additionally, it probes aspects of method development that are generally not discussed, such as how exactly to calibrate an assay or where to place quality controls, using examples from the literature. This review intends to provide a comprehensive resource and induce critical thinking around the experiments for and execution of developing a clinically meaningful LC-MS/MS assay.
Collapse
Affiliation(s)
- Brian A. Rappold
- Laboratory Corporation of America Holdings, Research Triangle Park, NC, USA
| |
Collapse
|
6
|
Dogra R, Kumar M, Kumar A, Roverso M, Bogialli S, Pastore P, Mandal UK. Derivatization, an Applicable Asset for Conventional HPLC Systems without MS Detection in Food and Miscellaneous Analysis. Crit Rev Anal Chem 2022; 53:1807-1827. [PMID: 35201944 DOI: 10.1080/10408347.2022.2042671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
One of the most valuable practices for analyzing not-so-analytical-friendly analytes in complex, heterogenous matrices is derivatization. Availability of numerous derivatizing reagents (DRs) makes the modification of analyte more exploitable in terms of an analytical perspective. A wide array of derivatization techniques like pre or post-column, in-situ, enzymatic, ultrasound-assisted, microwave-assisted, photochemical derivatization has added much-needed methodological strength in analyzing intricate analytical matrices (food, water, and soil). In recent years, analytical chemistry has achieved greater heights through the development of new sensitive methods with simple conventional instruments like High-Performance Liquid Chromatography (HPLC) devoid of Mass detectors. The prompt availability of these straightforward instruments also makes it a favorable option for routine analysis in food, environmental, bioanalytical chemistry. Analyzing food, environmental or bioanalytical specimen has some of the most problematic aspects, like the low concentration of the analytes accompanied by not too suitable analytical properties. Even though conventional HPLC lacks the required sensitivity but merger with derivatization can lead to a remarkable increase in sensitivity. In recent years there has been a lot of application of diverse derivatizations to increase the sensitivity and selectivity of the analyte for available instruments, resulting in notable findings. Therefore, this review describes the application of derivatization principles in the analysis of analytes in food and additional matrices using conventional HPLC instruments such as HPLC-UV, HPLC-DAD, and HPLC-FD. In this article, we will briefly review the different modes and multiple types of derivatizing reagents with their mechanisms and importance for encouraging the use of established HPLC instruments.
Collapse
Affiliation(s)
- Raghav Dogra
- Department of Chemical Sciences, University of Padova, Via Marzolo 1, 35131, Padova, Italy
| | - Mohit Kumar
- Department of Pharmaceutical Sciences & Technology, Maharaja Ranjit Singh Punjab Technical University, Bathinda, 151001, Punjab, India
| | - Arvind Kumar
- Maharaja Agrasen University, Baddi, Solan, Himachal Pradesh, India
| | - Marco Roverso
- Department of Chemical Sciences, University of Padova, Via Marzolo 1, 35131, Padova, Italy
| | - Sara Bogialli
- Department of Chemical Sciences, University of Padova, Via Marzolo 1, 35131, Padova, Italy
| | - Paolo Pastore
- Department of Chemical Sciences, University of Padova, Via Marzolo 1, 35131, Padova, Italy
| | - Uttam Kumar Mandal
- Department of Pharmaceutical Sciences & Technology, Maharaja Ranjit Singh Punjab Technical University, Bathinda, 151001, Punjab, India
| |
Collapse
|
7
|
Progress and Challenges in Quantifying Carbonyl-Metabolomic Phenomes with LC-MS/MS. Molecules 2021; 26:molecules26206147. [PMID: 34684729 PMCID: PMC8541004 DOI: 10.3390/molecules26206147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 09/30/2021] [Accepted: 10/01/2021] [Indexed: 12/17/2022] Open
Abstract
Carbonyl-containing metabolites widely exist in biological samples and have important physiological functions. Thus, accurate and sensitive quantitative analysis of carbonyl-containing metabolites is crucial to provide insight into metabolic pathways as well as disease mechanisms. Although reversed phase liquid chromatography electrospray ionization mass spectrometry (RPLC-ESI-MS) is widely used due to the powerful separation capability of RPLC and high specificity and sensitivity of MS, but it is often challenging to directly analyze carbonyl-containing metabolites using RPLC-ESI-MS due to the poor ionization efficiency of neutral carbonyl groups in ESI. Modification of carbonyl-containing metabolites by a chemical derivatization strategy can overcome the obstacle of sensitivity; however, it is insufficient to achieve accurate quantification due to instrument drift and matrix effects. The emergence of stable isotope-coded derivatization (ICD) provides a good solution to the problems encountered above. Thus, LC-MS methods that utilize ICD have been applied in metabolomics including quantitative targeted analysis and untargeted profiling analysis. In addition, ICD makes multiplex or multichannel submetabolome analysis possible, which not only reduces instrument running time but also avoids the variation of MS response. In this review, representative derivatization reagents and typical applications in absolute quantification and submetabolome profiling are discussed to highlight the superiority of the ICD strategy for detection of carbonyl-containing metabolites.
Collapse
|
8
|
Penell JC, Kushnir MM, Lind L, Bergquist J, Bergquist J, Lind PM, Naessen T. Concentrations of nine endogenous steroid hormones in 70-year-old men and women. Endocr Connect 2021; 10:511-520. [PMID: 33878730 PMCID: PMC8183619 DOI: 10.1530/ec-21-0045] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 04/16/2021] [Indexed: 12/15/2022]
Abstract
OBJECTIVES Circulating concentrations of endogenous steroids have systemic implications on health in elderly. However, population-based age- and ethnicity-specific data are scarce. The aim was to report sex-specific plasma concentrations of endogenous sex and adrenal steroids in elderly Swedish Caucasians, to examine the impact of BMI and to present concentrations in apparently healthy subjects. METHODS A population-based observational study of 70-year olds, including 684 community-dwelling men and women enrolled in the PIVUS study, Sweden. Median plasma concentrations were determined using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for pregnenolone, 17-hydroxypregnenolone, 17-hydroxy-progesterone, 11-deoxycortisol, DHEA, androstenedione, testosterone, estrone and estradiol. RESULTS Plasma concentrations were significantly higher in men (n = 452) than in women (n = 232) for estradiol: median 61.3 pmol/L (95% CI, 11.4, 142.7) vs 18.4 (4.0, 127.3), for estrone: 92.8 (33.3, 206) vs 71.6 (17.8, 209) pmol/L, and for testosterone 13.8 (5.7, 28.0) vs 0.7 (0.2, 2.0) nmol/L. Higher concentrations of estrone and estradiol were observed in obese than non-obese women. Compared to non-obese men, obese men had lower concentrations of testosterone and its precursors: 17-hydroxypregnenolone, 17-hydroxyprogesterone, androstenedione and DHEA. The subgroup of apparently healthy individuals had median values > 20% lower for estrone and estradiol in women but slightly higher for testosterone in both sexes. CONCLUSIONS Concentrations of estradiol, estrone and testosterone were higher in 70-year-old men than in women. BMI associated positively to estradiol and estrone in women and negatively to testosterone in men. Apparently healthy women had lower median concentrations of estradiol and estrone and men had higher median testosterone compared to all individuals.
Collapse
Affiliation(s)
- Johanna Christina Penell
- Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
- Department of Medical Sciences, Occupational and Environmental Medicine, Uppsala University, Uppsala, Sweden
- Correspondence should be addressed to J C Penell:
| | - Mark M Kushnir
- Department of Pathology, University of Utah School of Medicine, Salt Lake City, Utah, USA
- ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, Utah, USA
| | - Lars Lind
- Department of Medical Sciences, Cardiovascular Epidemiology, Uppsala University, Uppsala, Sweden
| | - Jonatan Bergquist
- Department of Chemistry – BMC, Analytical Chemistry, Uppsala University, Uppsala, Sweden
| | - Jonas Bergquist
- Department of Pathology, University of Utah School of Medicine, Salt Lake City, Utah, USA
- Department of Chemistry – BMC, Analytical Chemistry, Uppsala University, Uppsala, Sweden
| | - P Monica Lind
- Department of Medical Sciences, Occupational and Environmental Medicine, Uppsala University, Uppsala, Sweden
| | - Tord Naessen
- Department of Women’s and Children’s Health, Uppsala University, Uppsala, Sweden
| |
Collapse
|
9
|
Faqehi AM, Denham SG, Naredo G, Cobice DF, Khan S, Simpson JP, Sabil G, Upreti R, Gibb F, Homer NZ, Andrew R. Derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry. J Chromatogr A 2021; 1640:461933. [PMID: 33588275 PMCID: PMC7938423 DOI: 10.1016/j.chroma.2021.461933] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 01/19/2021] [Accepted: 01/20/2021] [Indexed: 11/19/2022]
Abstract
Quantitative analysis of low abundance androgens in human plasma. Quantitation of androgens over physiological range in men and post-menopausal women. Use of hydrazine derivatives improves analytical sensitivity.
Liquid Chromatography tandem mass spectrometry (LC-MS/MS) is the gold-standard approach for androgen analysis in biological fluids, superseding immunoassays in selectivity, particularly at low concentrations. While LC-MS/MS is established for analysis of testosterone and androstenedione, 5α-dihydrotestosterone (DHT) presents greater analytical challenges. DHT circulates at low nanomolar concentrations in men and lower in women, ionizing inefficiently and suffering from isobaric interference from other androgens. Even using current LC-MS/MS technology, large plasma volumes (>0.5 mL) are required for detection, undesirable clinically and unsuitable for animals. This study investigated derivatization approaches using hydrazine-based reagents to enhance ionization efficiency and sensitivity of analysis of DHT by LC-MS/MS. Derivatization of DHT using 2-hydrazino-1-methylpyridine (HMP) and 2-hydrazino-4-(trifluoromethyl)-pyrimidine (HTP) were compared. A method was validated using an UHPLC interfaced by electrospray with a triple quadruple mass spectrometer , analyzing human plasma (male and post-menopausal women) following solid-phase extraction. HMP derivatives were selected for validation affording greater sensitivity than those formed with HTP. HMP derivatives were detected by selected reaction monitoring (DHT-HMP m/z 396→108; testosterone-HMP m/z 394→108; androstenedione-HMP m/z 392→108). Chromatographic separation of androgen derivatives was optimized, carefully separating isobaric interferents and acceptable outputs for precision and trueness achieved following injection of 0.4 pg on column (approximately 34 pmol/L). HMP derivatives of all androgens tested could be detected in low plasma volumes: male (100 µL) and post-menopausal female (200 µL), and derivatives were stable over 30 days at -20°C. In conclusion, HMP derivatization, in conjunction with LC-MS/MS, is suitable for quantitative analysis of DHT, testosterone and androstenedione in low plasma volumes, offering advantages in sensitivity over current methodologies.
Collapse
Affiliation(s)
- Abdullah Mm Faqehi
- University/British Heart Foundation Centre for Cardiovascular Science, United Kingdom.
| | - Scott G Denham
- Mass Spectrometry Core, Edinburgh Clinical Research Facility, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, United Kingdom.
| | - Gregorio Naredo
- Mass Spectrometry Core, Edinburgh Clinical Research Facility, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, United Kingdom
| | - Diego F Cobice
- University/British Heart Foundation Centre for Cardiovascular Science, United Kingdom.
| | - Shazia Khan
- Mass Spectrometry Core, Edinburgh Clinical Research Facility, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, United Kingdom.
| | - Joanna P Simpson
- University/British Heart Foundation Centre for Cardiovascular Science, United Kingdom.
| | - Ghazali Sabil
- University/British Heart Foundation Centre for Cardiovascular Science, United Kingdom
| | - Rita Upreti
- University/British Heart Foundation Centre for Cardiovascular Science, United Kingdom
| | - Fraser Gibb
- University/British Heart Foundation Centre for Cardiovascular Science, United Kingdom.
| | - Natalie Zm Homer
- Mass Spectrometry Core, Edinburgh Clinical Research Facility, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, United Kingdom.
| | - Ruth Andrew
- University/British Heart Foundation Centre for Cardiovascular Science, United Kingdom; Mass Spectrometry Core, Edinburgh Clinical Research Facility, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, United Kingdom.
| |
Collapse
|
10
|
Dutheil F, de Saint Vincent S, Pereira B, Schmidt J, Moustafa F, Charkhabi M, Bouillon-Minois JB, Clinchamps M. DHEA as a Biomarker of Stress: A Systematic Review and Meta-Analysis. Front Psychiatry 2021; 12:688367. [PMID: 34295276 PMCID: PMC8290065 DOI: 10.3389/fpsyt.2021.688367] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 05/28/2021] [Indexed: 12/13/2022] Open
Abstract
Background: Psychosocial stress is a significant public health problem inducing consequences for quality of life. Results about the use of dehydroepiandrosterone (DHEA) as a biomarker of acute stress are conflicting. We conducted a systematic review and meta-analysis to demonstrate that DHEA levels could be a biomarker of stress. Methods: PubMed, Cochrane Library, Embase, and ScienceDirect databases were searched on March 19, 2021 using the keywords "acute stress" AND "DHEA" OR "Dehydroepiandrosterone." Articles needed to describe our primary outcome, i.e., induction of acute stress and at least two measures of DHEA. Results: We included 14 studies, with a total of 631 participants, in our meta-analysis. The DHEA levels increased overtime after acute stress [standardized mean difference (SMD) = 1.56, 95%CI = 1.13-1.99]. Stratification by time showed a main peak at the end of stress (SMD = 2.43, 95%CI = 1.59-3.27), followed by a progressive decrease (coefficient = -0.11, 95%CI = -0.19 to -0.17, p = 0.020). There was no significant change 1 h after the end of acute stress. Metaregressions showed an impact of mental stress (SMD = 2.04, 95%CI = 1.43-2.65), sex (SMD = 0.02, 95%CI = 0.00-0.04), age (SMD = -0.12, 95%CI = -0.2 to -0.05), and obesity (SMD = 0.31, 95%CI = -0.00 to 0.63). There was no difference whatever the type of fluid (blood or saliva) and the measurement technique used. Conclusions: DHEA is a biomarker of acute stress, with a short-term increase (1 h). DHEA increases following acute mental stress, whatever the type and duration of mental stress. Women, young people, and obese individuals had a higher response. Blood and saliva measures were comparable.
Collapse
Affiliation(s)
- Frédéric Dutheil
- Université Clermont Auvergne, CNRS, LaPSCo, Physiological and Psychosocial Stress, CHU Clermont-Ferrand, Occupational and Environmental Medicine, Wittyfit, Clermont-Ferrand, France
| | - Sarah de Saint Vincent
- Université Clermont Auvergne, Occupational and Environmental Medicine, Clermont-Ferrand, France
| | - Bruno Pereira
- CHU Clermont-Ferrand, CHU Clermont-Ferrand, Clinical Research and Innovation Direction, Clermont-Ferrand, France
| | - Jeannot Schmidt
- Université Clermont Auvergne, CNRS, LaPSCo, Physiological and Psychosocial Stress, CHU Clermont-Ferrand, Emergency Department, Clermont-Ferrand, France
| | - Farès Moustafa
- Université Clermont Auvergne, CHU Clermont-Ferrand, Emergency Department, Clermont-Ferrand, France
| | - Morteza Charkhabi
- Université Clermont Auvergne, CNRS, LaPSCo, Physiological and Psychosocial Stress, Clermont-Ferrand, France
| | - Jean-Baptiste Bouillon-Minois
- Université Clermont Auvergne, CNRS, LaPSCo, Physiological and Psychosocial Stress, CHU Clermont-Ferrand, Emergency Department, Clermont-Ferrand, France
| | - Maëlys Clinchamps
- CHU Clermont-Ferrand, CHU Clermont-Ferrand, Occupational and Environmental Medicine, Clermont-Ferrand, France
| |
Collapse
|
11
|
Song Z, Gao H, Xie W, Sun Q, Liang K, Li Y. Quantitative MALDI-MS assay of steroid hormones in plasma based on hydroxylamine derivatization. Anal Biochem 2020; 616:114089. [PMID: 33359147 DOI: 10.1016/j.ab.2020.114089] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 12/16/2020] [Accepted: 12/18/2020] [Indexed: 12/26/2022]
Abstract
Measuring the concentrations of steroid hormones in plasma is critical for understanding their role in various vital physiological processes. The detection of underivatized steroid hormones in biofluids through mass spectrometry (MS) is typically hindered by low ionization efficiency. We described a novel matrix-assisted laser desorption/ionization-MS (MALDI-MS) approach based on hydroxylamine derivatization (HA-D) to analyze low-concentration steroid hormones in plasma. The ketonic carbonyl group containing steroid hormones could be derivatized using HA to form oxime derivatives, which considerably enhanced the MS sensitivity for detecting steroid hormones. By using the optimized conditions, estrone (E1), testosterone (T), and progesterone (Prog), could be simultaneously quantified in plasma with a limit of detection (LOD) from 0.019 to 0.031 nM, recoveries from 86% to 108%, and coefficient of variation (CV%) from 4.59% to 11.90%. HA-D/MALDI-MS exhibited higher sensitivity than those using Girard T (GT). To establish potential utility of our method, we characterized fatty liver patient plasmas to demonstrate that the HA-D/MALDI-MS procedure could generate quantitative results comparable to the current clinical liquid chromatography-electrospray ionization tandem MS (LC-ESI MS/MS) method. This approach facilitates the rapid and accurate characterization of plasma hormones, and renders the MALDI-MS approach for steroid hormones more adaptable for clinical research and use.
Collapse
Affiliation(s)
- Zhijing Song
- Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Huanyu Gao
- Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101, China
| | - Wenchun Xie
- Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101, China
| | - Qing Sun
- Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101, China
| | - Kai Liang
- Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101, China; Guangzhou Regenerative Medicine and Health Guangdong Laboratory, China.
| | - Yan Li
- Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101, China; Guangzhou Regenerative Medicine and Health Guangdong Laboratory, China.
| |
Collapse
|
12
|
Zheng J, Huang S, Tong Y, Wei S, Chen G, Huang S, Ouyang G. In-situ layer-by-layer synthesized TpPa-1 COF solid-phase microextraction fiber for detecting sex hormones in serum. Anal Chim Acta 2020; 1137:28-36. [PMID: 33153606 DOI: 10.1016/j.aca.2020.08.047] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 08/18/2020] [Accepted: 08/24/2020] [Indexed: 01/18/2023]
Abstract
The secretion disorder of sex hormones is the source that leads to the occurrence of many diseases such as polycystic ovarian syndrome (PCOS), hyperandrogenism and so on. There exist physiological changes in human body when slight fluctuations in concentrations of sex hormones happen. Therefore, it's of great significance for accurate detection of sex hormones in human body. In this work, TpPa-1 COF solid-phase microextraction (SPME) fiber was prepared using high-efficient in-situ synthesis strategy and coupled with HPLC-MS/MS to detect three sex hormones, including Progesterone (P), testosterone (T) and dehydroepiandrosterone (DHEA) in human serum. The thickness of the coating reached 7 μm within 2 h. Under the optimal conditions, the established method presented low limit of detections (LODs, ≤ 0.75 ng/mL), wide linear ranges (0.100-100 ng mL-1) and good reproducibility, and three sex hormones (T, P, DHEA) were successfully detected and quantified in human serum. In conclusion, the established SPME method presented high-efficient fiber preparation and good analytical performances of sex hormone detection, therefore was in great potential for application in clinical.
Collapse
Affiliation(s)
- Jiating Zheng
- KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat- Sen University, Guangzhou, Guangdong, 510275, China
| | - Shuyao Huang
- KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat- Sen University, Guangzhou, Guangdong, 510275, China
| | - Yuanjun Tong
- KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat- Sen University, Guangzhou, Guangdong, 510275, China
| | - Songbo Wei
- KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat- Sen University, Guangzhou, Guangdong, 510275, China
| | - Guosheng Chen
- KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat- Sen University, Guangzhou, Guangdong, 510275, China
| | - Siming Huang
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics, Sun Yat- Sen Memorial Hospital, Guangzhou, Guangdong, 510120, China
| | - Gangfeng Ouyang
- KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat- Sen University, Guangzhou, Guangdong, 510275, China; Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals, Guangdong Institute of Analysis (China National Analytical Center Guangzhou), Guangzhou, 510070, China.
| |
Collapse
|
13
|
Sun G, Xue J, Li L, Li X, Cui Y, Qiao B, Wei D, Li H. Quantitative determination of human serum testosterone via isotope dilution ultra‑performance liquid chromatography tandem mass spectrometry. Mol Med Rep 2020; 22:1576-1582. [PMID: 32626990 PMCID: PMC7339657 DOI: 10.3892/mmr.2020.11235] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2019] [Accepted: 05/21/2020] [Indexed: 12/03/2022] Open
Abstract
Quantification of testosterone serves an important role in the differential diagnosis of androgen-related endocrine diseases. Mass spectrometry exhibits higher accuracy and lower variability than immunoassays, especially at low testosterone concentrations. The present study developed and validated an isotope dilution ultra-performance liquid chromatography tandem mass spectrometry method for determination of human serum testosterone. The serum was equilibrated with an isotopic internal standard and treated with acidic buffer to release hormones from their binding proteins. Testosterone was extracted via two serial liquid-liquid extractions. In the first stage, the lipid fractions from an acidic buffer solution were isolated using ethyl acetate and n-hexane. The organic phase was evaporated and reconstituted in a basic buffer solution. In the second stage, the polar impurities of n-hexane extraction were removed. Total testosterone in serum was quantified via ultra-performance liquid chromatography tandem mass spectrometry in multiple reaction monitoring mode with positive electrospray ionization. The coefficient of variation of the method for intra- and inter-assay was 2.13% (1.40–2.77%) and 3.44% (3.06–3.66%), respectively. The recovery ranged from 94.32 to 108.60% for different samples. The limit of detection was 0.50 ng/dl and the linear range was from 1.00 to 1,000.00 ng/dl. In addition, the extraction efficiency in three different levels of quality control of the serum ranged from 85.02 to 93.29%. Moreover, structural analogues were investigated and were not indicated to affect the quantification of testosterone. The present method may enable quantification of testosterone in a clinical setting with high precision and accuracy.
Collapse
Affiliation(s)
- Guang Sun
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Hexi, Tianjin 300203, P.R. China
| | - Jinmei Xue
- School of Chemical Engineering and Technology, Tianjin University, Jinnan, Tianjin 300350, P.R. China
| | - Liuxu Li
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Hexi, Tianjin 300203, P.R. China
| | - Xue Li
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Hexi, Tianjin 300203, P.R. China
| | - Yaqiong Cui
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Hexi, Tianjin 300203, P.R. China
| | - Bin Qiao
- School of Chemical Engineering and Technology, Tianjin University, Jinnan, Tianjin 300350, P.R. China
| | - Dianjun Wei
- Department of Clinical Laboratory, Hebei Yanda Hospital, Yanda International Health City, Sanhe, Hebei 065201, P.R. China
| | - Huiqiang Li
- Department of Clinical Immunology, School of Medical Laboratory, Tianjin Medical University, Hexi, Tianjin 300203, P.R. China
| |
Collapse
|
14
|
Fragkaki AG, Petropoulou G, Athanasiadou I, Kiousi P, Kioukia‐Fougia N, Archontaki H, Bakeas E, Angelis YS. Determination of anabolic androgenic steroids as imidazole carbamate derivatives in human urine using liquid chromatography–tandem mass spectrometry. J Sep Sci 2020; 43:2154-2161. [DOI: 10.1002/jssc.202000036] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 02/25/2020] [Accepted: 02/26/2020] [Indexed: 12/31/2022]
Affiliation(s)
- Argyro G. Fragkaki
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
| | - Georgia Petropoulou
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
- Laboratory of Analytical ChemistryDepartment of ChemistryNational & Kapodistrian University of Athens Athens Greece
| | | | - Polyxeni Kiousi
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
| | - Nassia Kioukia‐Fougia
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
| | - Helen Archontaki
- Laboratory of Analytical ChemistryDepartment of ChemistryNational & Kapodistrian University of Athens Athens Greece
| | - Evangelos Bakeas
- Laboratory of Analytical ChemistryDepartment of ChemistryNational & Kapodistrian University of Athens Athens Greece
| | - Yiannis S. Angelis
- Doping Control Laboratory of AthensInstitute of Biosciences & ApplicationsNational Center for Scientific Research “Demokritos” Athens Greece
| |
Collapse
|
15
|
Al-Khadhra RS. The determination of common anabolic steroid and stimulants in nutritional supplements by HPLC-DAD and LC-MS. J Chromatogr Sci 2020; 58:355-361. [DOI: 10.1093/chromsci/bmz121] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 06/28/2019] [Accepted: 08/07/2019] [Indexed: 12/17/2022]
Abstract
Abstract
A high-performance liquid chromatography method employing a diode-array detector and mass spectrometry detector was developed, validated and implemented for determining Synephrine, Caffeine, Clenbuterol, Nandrolone, Testosterone and Methylhexaneamine in Nutritional supplements. The use of Nutritional supplements is widespread. Hazards relating to concentration, composition, individual contaminants, supplements interactions as well as positive doping results among athletes present increasing concerns regarding nutritional supplement consuming. The proposed method was validated according to the International Conference on the Harmonization of the Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) standards. The proposed method observed to be accurate, linear, precise, sensitive, required minimal sample preparation and uncomplicated mobile phase. The implementation of the proposed method on nine commercial supplements shows that inaccurate labeling for some supplements regarding the concentration of the ingredients.
Collapse
Affiliation(s)
- Riyadh Salih Al-Khadhra
- Faculty of Health and Wellbeing, Sheffield Hallam University, Howard Street, Sheffield S1 1wb, UK
| |
Collapse
|
16
|
Liu Q, Chi Q, Fan RT, Tian HD, Wang X. Quantitative-Profiling Method of Serum Steroid Hormones by Hydroxylamine-Derivatization HPLC-MS. NATURAL PRODUCTS AND BIOPROSPECTING 2019; 9:201-208. [PMID: 30968349 PMCID: PMC6538747 DOI: 10.1007/s13659-019-0204-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Accepted: 04/03/2019] [Indexed: 05/17/2023]
Abstract
A sensitive and rapid high performance liquid chromatography-mass spectrometry (HPLC-MS) method was developed and validated for simultaneous quantification of ten steroid hormones, including estrogens, androgens, progesterones, and corticosteroids four classes of steroids. The following ten steroid hormones were analyzed: progesterone, 21-deoxycortisol, estrone, 4-androstenedione, testosterone, dihydro-testosterone, androstenone, dehydroepiandrosterone, corticosterone and cortisone. Stable deuterated isotopes were used as internal standards for quantification. Sample preparation with and without derivatization were performed after liquid-liquid extraction, and the corresponding results were compared according to sensitivity and selectivity. Hydroxylamine derivatization was found to improve the ionization efficiency of the analytes for electrospray ionization MS analysis. The gradient of mobile phase and experimental parameters for HPLC separation were optimized. The lower limits of quantification were in the range of 0.05-5 ng mL-1 with wide linear range for the ten steroid hormones. The intra-day precision < 11.1% and recovery of 84.5-120% with negligible matrix effect were achieved, where within the acceptance limits of the FDA guideline. Total HPLC-MS analysis time was 6 min. This method enables simultaneous quantification of steroids in human serum. It will be helpful for the serum steroid profiling in order to understand various endocrinology diseases.
Collapse
Affiliation(s)
- Qi Liu
- Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan, 430074, Hubei, People's Republic of China
| | - Quan Chi
- Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan, 430074, Hubei, People's Republic of China
| | - Ru-Ting Fan
- Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan, 430074, Hubei, People's Republic of China
| | - Hui-Dong Tian
- Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan, 430074, Hubei, People's Republic of China
| | - Xian Wang
- Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan, 430074, Hubei, People's Republic of China.
| |
Collapse
|
17
|
Mirzajani R, Kardani F, Ramezani Z. A nanocomposite consisting of graphene oxide, zeolite imidazolate framework 8, and a molecularly imprinted polymer for (multiple) fiber solid phase microextraction of sterol and steroid hormones prior to their quantitation by HPLC. Mikrochim Acta 2019; 186:129. [DOI: 10.1007/s00604-018-3217-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Accepted: 12/28/2018] [Indexed: 12/17/2022]
|
18
|
Desai R, Harwood DT, Handelsman DJ. Simultaneous measurement of 18 steroids in human and mouse serum by liquid chromatography-mass spectrometry without derivatization to profile the classical and alternate pathways of androgen synthesis and metabolism. CLINICAL MASS SPECTROMETRY (DEL MAR, CALIF.) 2019; 11:42-51. [PMID: 34841072 PMCID: PMC8620903 DOI: 10.1016/j.clinms.2018.12.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 12/26/2018] [Accepted: 12/30/2018] [Indexed: 11/22/2022]
Abstract
BACKGROUND The recently identified alternate, or backdoor, pathway of DHT synthesis provides important novel information on androgen biosynthesis beyond the classical pathway. We report a rapid and versatile liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to simultaneously and accurately quantify key steroids in human or mouse serum involved in either the classical or backdoor androgen synthesis pathways. METHODS Serum (200 µL) fortified with isotopically labelled internal standards underwent liquid-liquid extraction (LLE) with MTBE and extracts were analysed on a LC-MS/MS. The targeted steroids for quantification were testosterone (T), dihydrotestosterone (DHT), 5α-androstane-3α,17β-diol (3α diol), 5α-androstane-3β,17β-diol (3β diol), dehydroepiandrosterone (DHEA), androstenedione (A4), androsterone (AD), estradiol (E2), estrone (E1), progesterone (P4), pregnenolone (P5), androstenediol (Adiol), 17-hydroxyprogesterone (17-OHP4) and 17-hydroxypregnenolone (17-OHP5), corticosterone (B), cortisol (F), allopregnanolone (Allo-P5) and dihydroprogesterone (DHP). RESULTS The limits of quantification (LOQ) were 5 pg/mL for E2 and E1, 25 pg/mL for T, 50 pg/mL for A4 and 0.10 ng/mL for DHT, 17OHP5, P4, P5, AD, Adiol, DHEA, AlloP5 and 0.20 ng/mL for 17OHP4, 3α diol, 3β diol, DHP, 0.25 ng/mL for B and 1 ng/mL for F. Accuracy, precision, reproducibility and recovery were within acceptable limits for bioanalytical method validation. The method is illustrated in human and mouse, male and female serum. CONCLUSIONS The presented method is sufficiently sensitive, specific and reproducible to meet the quality criteria for routine laboratory application for accurate quantitation of 18 steroid concentrations in male and female serum from humans or mice for the purpose of profiling androgen synthesis and metabolism pathways.
Collapse
Key Words
- 17OHP4, 17-hydroxyprogesterone
- 17OHP5, 17hydroxypregnenolone
- 3α diol, 5α-androstane-3α17β-diol
- 3β diol, 5α-androstane-3β17β-diol
- A4, androstenedione
- AD, androsterone
- APPI, atmospheric pressure photoionization
- Adiol, androstenediol
- AlloP5, allopregnanolone
- Androgen
- B, corticosterone
- CSP, Charcoal Stripped Plasma
- DHEA, dehydroepiandrosterone
- DHP, dihydroprogesterone
- DHT, dihydrotestosterone
- Dihydrotestosterone
- E1, estrone
- E2, estradiol
- F, cortisol
- IS, internal standard
- LOD, lower limit of detection
- LOQ, lower limit of quantification
- Liquid chromatography–mass spectrometry
- ME, matrix effect
- MTBE, methyl tert-butyl ether
- NMI, National Measurement Institute
- P4, progesterone
- P5, pregnenolone
- S/N, signal-to-noise ratio
- Steroidogenesis
- T, testosterone
- Testosterone
Collapse
Affiliation(s)
- Reena Desai
- ANZAC Research Institute, University of Sydney, Sydney, NSW 2139, Australia
| | | | | |
Collapse
|
19
|
OHNO KI, HASEGAWA T, TAMURA T, UTSUMI H, YAMASHITA K. Proton Affinitive Derivatization for Highly Sensitive Determination of Testosterone and Dihydrotestosterone in Saliva Samples by LC-ESI-MS/MS. ANAL SCI 2018; 34:1017-1021. [DOI: 10.2116/analsci.18scp08] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Ken-ichi OHNO
- Faculty of Pharmaceutical Sciences, Tohoku Medical and Pharmaceutical University
| | - Tomomi HASEGAWA
- Faculty of Pharmaceutical Sciences, Tohoku Medical and Pharmaceutical University
| | - Tomomi TAMURA
- Faculty of Pharmaceutical Sciences, Tohoku Medical and Pharmaceutical University
| | - Haruka UTSUMI
- Faculty of Pharmaceutical Sciences, Tohoku Medical and Pharmaceutical University
| | | |
Collapse
|
20
|
Wang C, Shiraishi S, Leung A, Baravarian S, Hull L, Goh V, Lee PWN, Swerdloff RS. Corrigendum to "Validation of a testosterone and dihydrotestosterone liquid chromatography tandem mass spectrometry assay: interference and comparison with established methods" [Steroids Volume 73, Issue 13, 12 December 2008, Pages 1345-1352]. Steroids 2018; 135:108. [PMID: 29778140 PMCID: PMC6489135 DOI: 10.1016/j.steroids.2018.05.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Testosterone (T) and its metabolite dihydrotestosterone (DHT) are androgens with different biologic profiles. T and DHT measurements are required for assessment of patients with ambiguous genitalia, hirsutism, during 5 alpha reductase treatment of prostate disorders, and new androgen formulations. Our laboratory has developed and validated a method to simultaneously measure serum T and DHT with liquid chromatography tandem mass spectrometry (LC-MS/MS) for use in a clinical chemistry laboratory. Analysis of sera from blood collected in tubes containing clot activator gave results of T that were four fold higher than blood collected in plain tubes. Changing the ion pair selected for monitoring eliminated this interference by clot activators. Blood collected in fluoride coated tubes gave serum T and DHT levels that were 20 and 15 percent lower respectively than levels measured in blood collected in plain tubes (no additives). Addition of T enanthate to blood collected in plain tubes caused a dose related increase serum T levels due to the action of non-specific esterases in the red cells. This esterase activity could be avoided by using fluoride tubes for blood collection. Serum DHT levels were consistently lower when measured by LC-MS/MS versus radioimmunoassay. The differences were concentration dependent and the variance for the difference was large when serum DHT concentration was low. Celite chromatograph prior to radioimmunoassay reduced the differences between the two methods, thus confirming that higher levels of DHT obtained by immunoassays were probably due to interfering substances which were partially removed by Celite chromatography.
Collapse
Affiliation(s)
- Christina Wang
- General Clinical Research Center, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA; Division of Endocrinology, Department of Medicine, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA.
| | - Steve Shiraishi
- General Clinical Research Center, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA
| | - Andrew Leung
- Division of Endocrinology, Department of Medicine, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA
| | - Sima Baravarian
- Division of Endocrinology, Department of Medicine, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA
| | - Laura Hull
- Division of Endocrinology, Department of Medicine, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA
| | - Victor Goh
- General Clinical Research Center, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA
| | - Paul W N Lee
- General Clinical Research Center, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA; Division of Endocrinology, Department of Pediatrics, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA
| | - Ronald S Swerdloff
- Division of Endocrinology, Department of Medicine, Harbor-UCLA Medical Center and Los Angeles Biomedical Research Institute, 1000 Carson Street, Torrance, CA90509, USA
| |
Collapse
|
21
|
Liu C, Sheng X, Wang Y, Yin J, Huang W, Fan Y, Li Y, Zhang Y. A sensitive approach for simultaneous quantification of carbonyl and hydroxyl steroids using 96-well SPE plates based on stable isotope coded-derivatization-UPLC-MRM: method development and application. RSC Adv 2018; 8:19713-19723. [PMID: 35540992 PMCID: PMC9080693 DOI: 10.1039/c8ra01372a] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 05/02/2018] [Indexed: 11/25/2022] Open
Abstract
Steroid hormones are crucial substances that mediate a wide range of vital physiological functions. Because of the important biological significance of steroids, this paper presents a new targeted metabolic method based on adding stable isotope tags to hydroxyl containing and carbonyl containing steroid hormones with two pairs of synthesized derivatization reagents: deuterium 4-(dimethylamino)-benzoic acid (D4-DMBA), and D5-Girard P (D5-GP) using of ultra performance liquid chromatography-multiple reaction monitoring (UPLC-MRM). Firstly, an Oasis PRiME hydrophilic-lipophilic balance (HLB) 96-well solid phase extraction plate was used to pretreat a number of biological samples simultaneously. Secondly, hydroxyl and carbonyl steroids were labeled using two pairs of synthetic reagents, namely DMBA and D4-DMBA, and GP and D5-GP, respectively. Thirdly, the mixed products were detected using UPLC-MRM and the mass spectroscopy conditions were optimized. Methodology development showed that the sensitivity was enhanced 1 to >500-fold. Finally, the new method was applied to analysis of urine samples of healthy males, females and rats. The results revealed that the method can be sensitive and reliable for simultaneous quantification of steroid hormones containing hydroxyl and carbonyl groups in 12 min in a single run. This method provided a powerful tool for studying the metabolic mechanism of steroids and contributed to the development of targeted metabolomics. Steroid hormones are crucial substances that mediate a wide range of vital physiological functions.![]()
Collapse
Affiliation(s)
- Chuanxin Liu
- Tianjin State Key Laboratory of Modern Chinese Medicine
- School of Traditional Chinese Materia Medica
- Tianjin University of Traditional Chinese Medicine
- Tianjin 300193
- China
| | - Xue Sheng
- Tianjin State Key Laboratory of Modern Chinese Medicine
- School of Traditional Chinese Materia Medica
- Tianjin University of Traditional Chinese Medicine
- Tianjin 300193
- China
| | - Yuming Wang
- Tianjin State Key Laboratory of Modern Chinese Medicine
- School of Traditional Chinese Materia Medica
- Tianjin University of Traditional Chinese Medicine
- Tianjin 300193
- China
| | - Jia Yin
- Tianjin State Key Laboratory of Modern Chinese Medicine
- School of Traditional Chinese Materia Medica
- Tianjin University of Traditional Chinese Medicine
- Tianjin 300193
- China
| | - Wei Huang
- Tianjin State Key Laboratory of Modern Chinese Medicine
- School of Traditional Chinese Materia Medica
- Tianjin University of Traditional Chinese Medicine
- Tianjin 300193
- China
| | - Yunshuang Fan
- State Key Laboratory of Separation Membranes and Membrane Processes
- Tianjin Polytechnic University
- Tianjin 300387
- China
- School of Environmental and Chemical Engineering
| | - Yubo Li
- Tianjin State Key Laboratory of Modern Chinese Medicine
- School of Traditional Chinese Materia Medica
- Tianjin University of Traditional Chinese Medicine
- Tianjin 300193
- China
| | - Yanjun Zhang
- Tianjin State Key Laboratory of Modern Chinese Medicine
- Tianjin University of Traditional Chinese Medicine
- Tianjin 300193
- China
| |
Collapse
|
22
|
Morote J, Comas I, Ferrer R, Planas J, Celma A, Regis L. Accuracy of serum luteinizing hormone and serum testosterone measurements to assess the efficacy of medical castration in prostate cancer patients. J Biomed Sci 2017; 24:81. [PMID: 29058606 PMCID: PMC5651562 DOI: 10.1186/s12929-017-0386-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Accepted: 10/07/2017] [Indexed: 01/28/2023] Open
Abstract
Background Luteinizing hormone-releasing hormone (LH-RH) agonists are the standard for androgen deprivation therapy (ADT) in prostate cancer (PCa) patients. Current guidelines recommend serum testosterone measurement to assess the efficacy of ADT and to define castration resistance. However, serum testosterone does not reflect the exclusive effect of castration due to its extratesticular production. The aim of this study is to analyze if serum LH reflects better than serum testosterone the activity of LH-RH agonists. Methods Serum LH and serum testosterone were measured with chemiluminescent immunoassay (CLIA) in a cohort study of 1091 participants: 488 PCa patients “on LH-RH agonists”, 303 “off LH-RH agonist” in whom LH-RH agonists were withdrawn, and 350 men with PCa suspicion “no LH-RH agonist” who never received LH-RH agonists. In a validation cohort of 147 PCa patients, 124 on “LH-RH agonists” and 19 “off LH-RH agonists”, serum testosterone was also measured with liquid chromatography and tandem mass spectrometry (LC MSMS). Results The area under the curve (AUC) to distinguish patients “on versus off LH-RH agonists” was 0.997 for serum LH and 0.740 for serum testosterone, P < 0.001. The 97.5 percentile of serum LH in patients “on LH-RH agonists” was 0.97 U/L, been the most efficient threshold 1.1 U/L. The AUCs for serum LH, testosterone measured with CLIA and with LC MSMS, in the validation cohort, were respectively 1.000, 0.646 and 0.814, P < 0.001. The efficacy to distinguish patients “on versus off LH-RH agonists” was 98.6%, 78.3%, and 89.5% respectively, using 1.1 U/L as threshold for serum LH and 50 ng/dL for serum testosterone regardless the method. Conclusions Serum LH is more accurate than serum testosterone regardless the method, to distinguish patients “on versus off LH-RH agonists”. The castrate level of serum LH is 1.1 U/l. These findings suggest that assessment of LH-RH agonist efficacy and castration resistance definition should be reviewed.
Collapse
Affiliation(s)
- Juan Morote
- Department of Urology, Vall d'Hebron Hospital, Universidad Autonoma de Barcelona, 14 Po Vall d'Hebron 119-129, 00173, Barcelona, Spain.
| | - Imma Comas
- Department of Biochemistry, Vall d'Hebron Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Roser Ferrer
- Department of Biochemistry, Vall d'Hebron Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Jacques Planas
- Department of Urology, Vall d'Hebron Hospital, Universidad Autonoma de Barcelona, 14 Po Vall d'Hebron 119-129, 00173, Barcelona, Spain
| | - Anna Celma
- Department of Urology, Vall d'Hebron Hospital, Universidad Autonoma de Barcelona, 14 Po Vall d'Hebron 119-129, 00173, Barcelona, Spain
| | - Lucas Regis
- Department of Urology, Vall d'Hebron Hospital, Universidad Autonoma de Barcelona, 14 Po Vall d'Hebron 119-129, 00173, Barcelona, Spain
| |
Collapse
|
23
|
The Effects of a 4-Week, Intensified Training, and Competition Period on Salivary Hormones, Immunoglobulin A, Illness Symptoms, and Mood State in Elite Synchronised Swimmers. Sports (Basel) 2017; 5:sports5030064. [PMID: 29910424 PMCID: PMC5968973 DOI: 10.3390/sports5030064] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Revised: 08/25/2017] [Accepted: 08/27/2017] [Indexed: 11/28/2022] Open
Abstract
Given the limited research into the physiological and psychological demands of elite synchronised swimming, the aim of this study was to examine 10 elite female synchronised swimmers and analyse the relationship between training load, stress, illness episodes, and salivary biomarkers during a period of training and competition. Saliva samples were collected before (BASE), during an intensified training camp (CAMP), during an international competition period (COMP), and post competition recovery (REC) for analysis of cortisol, testosterone, and secretory immunoglobulin A (SIgA). Illness symptoms, Daily Analysis of Life Demands of Athletes (DALDA), and training load were also monitored. Training load significantly increased from BASE during CAMP and COMP (p < 0.01), and SIgA secretion was higher during COMP compared to BASE and CAMP (p < 0.01). There was no change in salivary testosterone; however, salivary cortisol was elevated during COMP compared to BASE (93%, p < 0.05). DALDA ‘a scores’ were correlated with salivary cortisol (r = 0.429, p = 0.0001). The study demonstrates that a short period of intensified training and competition did not have a detrimental effect on mucosal immunity in elite synchronised swimmers; however, swimmers displayed higher cortisol levels during the competition and increased stress symptoms.
Collapse
|
24
|
Zhou H, Wang Y, Gatcombe M, Farris J, Botelho JC, Caudill SP, Vesper HW. Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry. Anal Bioanal Chem 2017; 409:5943-5954. [PMID: 28801832 DOI: 10.1007/s00216-017-0529-x] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 07/05/2017] [Accepted: 07/18/2017] [Indexed: 12/13/2022]
Abstract
Reliable measurement of total testosterone and estradiol is critical for their use as biomarkers of hormone-related disorders in patient care and translational research. We developed and validated a mass spectrometry method to simultaneously quantify these analytes in human serum without chemical derivatization. Serum is equilibrated with isotopic internal standards and treated with acidic buffer to release hormones from their binding proteins. Lipids are isolated and polar impurities are removed by two serial liquid-liquid extraction steps. Total testosterone and estradiol are measured using liquid chromatography tandem mass spectrometry (LC-MS/MS) in combination of positive and negative electrospray ionization modes. The method shows broad analytical measurement range for both testosterone 0.03-48.5 nM (0.75-1400 ng/dL) and estradiol 11.0-5138 pM (2.99-1400 pg/mL) and excellent agreement with certified reference materials (mean bias less than 2.1% to SRM 971, BCR 576, 577, and 578) and a high order reference method (mean bias 1.25% for testosterone and -0.84% for estradiol). The high accuracy of the method was monitored and certified by CDC Hormone Standardization (HoSt) Program for 2 years with mean bias -0.7% (95% CI -1.6% to 0.2%) for testosterone and 0.1% (95% CI -2.2% to 2.3%) for estradiol. The method precision over a 2-year period for quality control pools at low, medium, and high concentrations was 2.7-2.9% for testosterone and 3.3-5.3% for estradiol. With the consistently excellent accuracy and precision, this method is readily applicable for high-throughput clinical and epidemiological studies.
Collapse
Affiliation(s)
- Hui Zhou
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Yuesong Wang
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Matthew Gatcombe
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Jacob Farris
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Julianne C Botelho
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Samuel P Caudill
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Hubert W Vesper
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA.
| |
Collapse
|
25
|
Tavita N, Greaves RF. Systematic review of serum steroid reference intervals developed using mass spectrometry. Clin Biochem 2017; 50:1260-1274. [PMID: 28733189 DOI: 10.1016/j.clinbiochem.2017.07.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2017] [Revised: 07/14/2017] [Accepted: 07/14/2017] [Indexed: 10/19/2022]
Abstract
The aim of this study was to perform a systematic review of the published literature to determine the available serum/plasma steroid reference intervals generated by mass spectrometry (MS) methods across all age groups in healthy subjects and to suggest recommendations to achieve common MS based reference intervals for serum steroids. MEDLINE, EMBASE and PubMed databases were used to conduct a comprehensive search for English language, MS-based reference interval studies for serum/plasma steroids. Selection of steroids to include was based on those listed in the Royal College of Pathologists of Australasia Quality Assurance Programs, Chemical Pathology, Endocrine Program. This methodology has been registered onto the PROSPERO International prospective register of systematic reviews (ID number: CRD42015029637). After accounting for duplicates, a total of 60 manuscripts were identified through the search strategy. Following critical evaluation, a total of 16 studies were selected. Of the 16 studies, 12 reported reference intervals for testosterone, 11 for 17 hydroxy-progesterone, nine for androstenedione, six for cortisol, three for progesterone, two for dihydrotestosterone and only one for aldosterone and dehydroepiandrosterone sulphate. No studies established MS-based reference intervals for oestradiol. As far as we are aware, this report provides the first comparison of the peer reviewed literature for serum/plasma steroid reference intervals generated by MS-based methods. The reference intervals based on these published studies can be used to inform the process to develop common reference intervals, and agreed reporting units for mass spectrometry based steroid methods.
Collapse
Affiliation(s)
- Nevada Tavita
- School of Health & Biomedical Sciences, RMIT University, Victoria, Australia
| | - Ronda F Greaves
- School of Health & Biomedical Sciences, RMIT University, Victoria, Australia; Murdoch Children's Research Institute, Melbourne, Australia..
| |
Collapse
|
26
|
Ellis AG, Zeglinski PT, Coleman KE, Whiting MJ. Dilute, derivatise and shoot: Measurement of urinary free metanephrines and catecholamines as ethyl derivatives by LC-MSMS. CLINICAL MASS SPECTROMETRY (DEL MAR, CALIF.) 2017; 4-5:34-41. [PMID: 39193131 PMCID: PMC11322754 DOI: 10.1016/j.clinms.2017.08.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Revised: 08/25/2017] [Accepted: 08/25/2017] [Indexed: 10/18/2022]
Abstract
Background The measurement of catecholamines and their metabolites in either urine or plasma is an important diagnostic test used to exclude the presence of neuroendocrine tumours. Because of weak chromatographic retention and potential ion-suppression, reverse-phase LC-MSMS is not ideal for analysis of these polar molecules. Here, we investigate derivatisation by ethylation as an alternative approach. Methods A simple and rapid method involving acetaldehyde and a reducing agent was used to convert urine free metanephrines and catecholamines, and their deuterated analogues as internal standards, to mono-ethyl or diethyl- derivatives. Using an Agilent 6460 triple-quadrupole mass spectrometer, precursor and product ion mass spectra were recorded to allow comparison of multiple reaction monitoring methods for both derivatised and non-derivatised analytes under reverse-phase LC-MSMS conditions with positive electrospray ionization. Results Conversion of biogenic amines to less polar ethyl derivatives increased their mass and enhanced the intensity of their molecular ions and fragments. Ethylation also improved the chromatographic properties of the amines, with greater retention and elution from reverse-phase HPLC columns with a methanol or acetonitrile gradient. The signal response of tandem mass spectrometric detection was increased up to 50-fold for ethyl metanephrines compared to non-derivatised compounds. This increase allowed for the omission of solid-phase extraction of urine as a clean-up step prior to analysis. The 'dilute-derivatise-shoot' method maintained analytical performance with respect to between-run imprecision (CV < 6%) and accuracy in an external quality assurance program. Gender-related ranges for free metanephrines in early-morning spot urines, collected from adult patients, were similar using either derivatised or non-derivatised samples. Conclusions The LC-MSMS detection of free urine biogenic amines can be greatly enhanced by ethyl derivatisation, which is easy and rapid to perform. Advantages include improved chromatography and lower limits of quantitation, that negate the requirement for solid-phase clean-up of urine prior to analysis. A disadvantage is the potential toxicity of the derivatising agents used if they are not handled appropriately.
Collapse
Affiliation(s)
- Andrew G. Ellis
- Clinical Pharmacology, Austin Health, Melbourne, Victoria 3084, Australia
- Department of Medicine, University of Melbourne, Melbourne 3000, Australia
| | | | | | - Malcolm J. Whiting
- Chemical Pathology, SA Pathology, Adelaide 5000, Australia
- Medical Biochemistry, Flinders University, Bedford Park, South Australia 5042, Australia
| |
Collapse
|
27
|
Kaul KL, Sabatini LM, Tsongalis GJ, Caliendo AM, Olsen RJ, Ashwood ER, Bale S, Benirschke R, Carlow D, Funke BH, Grody WW, Hayden RT, Hegde M, Lyon E, Murata K, Pessin M, Press RD, Thomson RB. The Case for Laboratory Developed Procedures: Quality and Positive Impact on Patient Care. Acad Pathol 2017; 4:2374289517708309. [PMID: 28815200 PMCID: PMC5528950 DOI: 10.1177/2374289517708309] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 04/06/2017] [Accepted: 04/10/2017] [Indexed: 12/16/2022] Open
Abstract
An explosion of knowledge and technology is revolutionizing medicine and patient care. Novel testing must be brought to the clinic with safety and accuracy, but also in a timely and cost-effective manner, so that patients can benefit and laboratories can offer testing consistent with current guidelines. Under the oversight provided by the Clinical Laboratory Improvement Amendments, laboratories have been able to develop and optimize laboratory procedures for use in-house. Quality improvement programs, interlaboratory comparisons, and the ability of laboratories to adjust assays as needed to improve results, utilize new sample types, or incorporate new mutations, information, or technologies are positive aspects of Clinical Laboratory Improvement Amendments oversight of laboratory-developed procedures. Laboratories have a long history of successful service to patients operating under Clinical Laboratory Improvement Amendments. A series of detailed clinical examples illustrating the quality and positive impact of laboratory-developed procedures on patient care is provided. These examples also demonstrate how Clinical Laboratory Improvement Amendments oversight ensures accurate, reliable, and reproducible testing in clinical laboratories.
Collapse
Affiliation(s)
- Karen L. Kaul
- Department of Pathology and Laboratory Medicine, NorthShore University HealthSystem, Evanston, IL, USA
| | - Linda M. Sabatini
- Department of Pathology and Laboratory Medicine, NorthShore University HealthSystem, Evanston, IL, USA
| | - Gregory J. Tsongalis
- Laboratory for Clinical Genomics and Advanced Technology, Department of Pathology, Dartmouth Hitchcock Medical Center and Norris Cotton Cancer Center, Lebanon, NH, USA
- Laboratory Medicine, Dartmouth Hitchcock Medical Center and Norris Cotton Cancer Center, Lebanon, NH, USA
| | - Angela M. Caliendo
- Department of Medicine, Alpert Medical School of Brown University, Providence, RI, USA
| | - Randall J. Olsen
- Department of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, TX, USA
| | | | | | - Robert Benirschke
- Department of Pathology and Laboratory Medicine, NorthShore University HealthSystem, Evanston, IL, USA
| | - Dean Carlow
- Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Birgit H. Funke
- Laboratory for Molecular Medicine, Massachusetts General Hospital, Boston, MA, USA
| | - Wayne W. Grody
- Departments of Pathology and Laboratory Medicine, Pediatrics and Human Genetics, UCLA School of Medicine, Los Angeles, CA, USA
| | - Randall T. Hayden
- Department of Pathology, St. Jude Children’s Research Hospital, Memphis, TN, USA
| | - Madhuri Hegde
- Department of Human Genetics, Emory University School of Medicine, Atlanta, GA, USA
| | - Elaine Lyon
- Pathology Department, University of Utah School of Medicine/ARUP Laboratories, Salt Lake City, UT, USA
| | - Kazunori Murata
- Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Melissa Pessin
- Department of Laboratory Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Richard D. Press
- Department of Pathology and Knight Cancer Institute, Oregon Health & Science University, Portland, OR, USA
| | - Richard B. Thomson
- Department of Pathology and Laboratory Medicine, NorthShore University HealthSystem, Evanston, IL, USA
| |
Collapse
|
28
|
Welsh KJ, Soldin SJ. DIAGNOSIS OF ENDOCRINE DISEASE: How reliable are free thyroid and total T3 hormone assays? Eur J Endocrinol 2016; 175:R255-R263. [PMID: 27737898 PMCID: PMC5113291 DOI: 10.1530/eje-16-0193] [Citation(s) in RCA: 73] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Accepted: 07/08/2016] [Indexed: 11/08/2022]
Abstract
Hypothyroidism is a very common disorder worldwide, for which the usual treatment is monotherapy with levothyroxine (L-T4). However, a number of patients treated with L-T4 continue to report symptoms of hypothyroidism despite seemingly normal levels of thyroid-stimulating hormone (TSH), free-T3 (FT3) and free-T4 (FT4) measured by immunoassay. This review summarizes the limitations of the immunoassays commonly used to measure thyroid hormone levels and emphasizes the advantages of the role of liquid chromatography-tandem mass spectrometry (LC-MS/MS). Immunoassays for free thyroid hormone are affected by alterations in serum binding proteins that occur in many physiological and disease states. Multiple studies show falsely normal values for T3, FT3 and FT4 by immunoassay that are below the reference interval when measured by (ultrafiltration) LC-MS/MS, a reference method. We suggest evaluation of thyroid hormone levels by ultrafiltration LC-MS/MS for patients who continue to experience hypothyroid symptoms on LT-4. This may help identify the approximately 20% subset of patients who would benefit from addition of T3 to their treatment regimen (combination therapy).
Collapse
Affiliation(s)
- Kerry J Welsh
- Clinical Chemistry DivisionDepartment of Laboratory Medicine, National Institutes of Health, Bethesda, Maryland, USA
| | - Steven J Soldin
- Clinical Chemistry DivisionDepartment of Laboratory Medicine, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
29
|
Abstract
Although mass spectrometry has been used clinically for decades, the advent of immunoassay technology moved the clinical laboratory to more labor saving automated platforms requiring little if any sample preparation. It became clear, however, that immunoassays lacked sufficient sensitivity and specificity necessary for measurement of certain analytes or for measurement of analytes in specific patient populations. This limitation prompted clinical laboratories to revisit mass spectrometry which could additionally be used to develop assays for which there was no commercial source. In this chapter, the clinical applications of mass spectrometry in therapeutic drug monitoring, toxicology, and steroid hormone analysis will be reviewed. Technologic advances and new clinical applications will also be discussed.
Collapse
Affiliation(s)
- D French
- University of California San Francisco, San Francisco, CA, United States.
| |
Collapse
|
30
|
Higashi T, Ogawa S. Chemical derivatization for enhancing sensitivity during LC/ESI-MS/MS quantification of steroids in biological samples: a review. J Steroid Biochem Mol Biol 2016; 162:57-69. [PMID: 26454158 DOI: 10.1016/j.jsbmb.2015.10.003] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2015] [Revised: 09/29/2015] [Accepted: 10/02/2015] [Indexed: 01/22/2023]
Abstract
Sensitive and specific methods for the detection, characterization and quantification of endogenous steroids in body fluids or tissues are necessary for the diagnosis, pathological analysis and treatment of many diseases. Recently, liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) has been widely used for these purposes due to its specificity and versatility. However, the ESI efficiency and fragmentation behavior of some steroids are poor, which lead to a low sensitivity. Chemical derivatization is one of the most effective methods to improve the detection characteristics of steroids in ESI-MS/MS. Based on this background, this article reviews the recent advances in chemical derivatization for the trace quantification of steroids in biological samples by LC/ESI-MS/MS. The derivatization in ESI-MS/MS is based on tagging a proton-affinitive or permanently charged moiety on the target steroid. Introduction/formation of a fragmentable moiety suitable for the selected reaction monitoring by the derivatization also enhances the sensitivity. The stable isotope-coded derivatization procedures for the steroid analysis are also described.
Collapse
Affiliation(s)
- Tatsuya Higashi
- Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda-shi, Chiba 278-8510, Japan.
| | - Shoujiro Ogawa
- Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda-shi, Chiba 278-8510, Japan
| |
Collapse
|
31
|
A novel approach to breast cancer prevention: reducing excessive ovarian androgen production in elderly women. Breast Cancer Res Treat 2016; 158:553-61. [DOI: 10.1007/s10549-016-3901-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Accepted: 07/05/2016] [Indexed: 10/21/2022]
|
32
|
Abstract
Steroid hormones are measured clinically to determine if a patient has a pathological process occurring in the adrenal gland, or other hormone responsive organs. They are very similar in structure making them analytically challenging to measure. Additionally, these hormones have vast concentration differences in human serum adding to the measurement complexity. GC–MS was the gold standard methodology used to measure steroid hormones clinically, followed by radioimmunoassay, but that was replaced by immunoassay due to ease of use. LC–MS/MS has now become a popular alternative owing to simplified sample preparation than for GC–MS and increased specificity and sensitivity over immunoassay. This review will discuss these methodologies and some new developments that could simplify and improve steroid hormone analysis in serum.
Collapse
|
33
|
Guo N, Liu P, Ding J, Zheng SJ, Yuan BF, Feng YQ. Stable isotope labeling - Liquid chromatography/mass spectrometry for quantitative analysis of androgenic and progestagenic steroids. Anal Chim Acta 2015; 905:106-14. [PMID: 26755144 DOI: 10.1016/j.aca.2015.12.010] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Revised: 11/27/2015] [Accepted: 12/01/2015] [Indexed: 11/16/2022]
Abstract
Steroid hormones play important roles in mammal at very low concentrations and are associated with numerous endocrinology and oncology diseases. Therefore, quantitative analysis of steroid hormones can provide crucial information for uncovering underlying mechanisms of steroid hormones related diseases. In the current study, we developed a sensitive method for the detection of steroid hormones (progesterone, dehydroepiandrosterone, testosterone, pregnenolone, 17-hydroxyprogesterone, androstenedione and 17α-hydroxypregnenolone) in body fluids by stable isotope labeling coupled with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this respect, a pair of isotopes labeling reagents, Girard reagent P (GP) and d5-Girard reagent P (d5-GP), were synthesized and utilized to label steroid hormones in follicular fluid samples and steroid hormone standards, respectively. The heavy labeled standards were used as internal standards for quantification to minimize quantitation deviation in MS analysis due to the matrix and ion suppression effects. The ionization efficiencies of steroid hormones were greatly improved by 4-504 folds through the introduction of a permanent charged moiety of quaternary ammonium from GP. Using the developed method, we successfully quantified steroid hormones in human follicular fluid. We found that the contents of testosterone and androstenedione exhibited significant increase while the content of pregnenolone had significant decrease in follicular fluid of polycystic ovarian syndrome (PCOS) patients compared with healthy controls, indicating that these steroid hormones with significant change may contribute to the pathogenesis of PCOS. Taken together, the developed stable isotope labeling coupled LC-ESI-MS/MS analysis demonstrated to be a promising method for the sensitive and accurate determination of steroid hormones, which may facilitate the in-depth investigation of steroid hormones related diseases.
Collapse
Affiliation(s)
- Ning Guo
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, PR China
| | - Ping Liu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, PR China
| | - Jun Ding
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, PR China
| | - Shu-Jian Zheng
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, PR China
| | - Bi-Feng Yuan
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, PR China
| | - Yu-Qi Feng
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, PR China.
| |
Collapse
|
34
|
Tran TS, Center JR, Seibel MJ, Eisman JA, Kushnir MM, Rockwood AL, Nguyen TV. Relationship between Serum Testosterone and Fracture Risk in Men: A Comparison of RIA and LC-MS/MS. Clin Chem 2015; 61:1182-90. [PMID: 26130584 DOI: 10.1373/clinchem.2015.242339] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Accepted: 06/09/2015] [Indexed: 11/06/2022]
Abstract
BACKGROUND Serum testosterone can be measured by LC-MS/MS and RIA. We investigated whether the testosterone-fracture relationship was affected by the method of measurement. METHODS We measured total testosterone (TT) by LC-MS/MS (TTLC-MS/MS) and RIA (TTRIA) in serum samples collected from 602 men whose incident fractures had been continuously ascertained by x-ray reports from 1989 to 2010. We measured bone mineral density (BMD) by dual-energy x-ray absorptiometry. The association between TT and fracture risk was assessed by the Cox proportional hazards model, taking into account the effect of age and BMD. RESULTS Mean TTLC-MS/MS was higher than TTRIA by 27 ng/dL (95% CI 13-41). The concordance correlation coefficient between TTLC-MS/MS and TTRIA was 0.72 (95% CI 0.68-0.76). The Deming regression equation linking the 2 measurements was ln(TTLC-MS/MS + 10) = 0.87 + 0.87 × ln(TTRIA + 10). The hazard ratio of fracture per SD decrease in TT was 1.32 (95% CI 1.12-1.54) for TTLC-MS/MS and 1.23 (1.06-1.43) for TTRIA. The correlation between predicted probabilities of fracture by TTLC-MS/MS and TTRIA was r = 0.96, with the mean difference being 0.01% (95% CI -6.1% to 6.2%). Slightly more patients were classified as having hypogonadism if TTRIA was used (29% vs 26%). CONCLUSIONS The concordance between LC-MS/MS and RIA in the measurement of serum TT was moderate. Moreover, the magnitude of association between testosterone and fracture risk in older men was largely unaffected by the method of measurement.
Collapse
Affiliation(s)
| | - Jacqueline R Center
- Osteoporosis and Bone Biology Program and Clinical School, St. Vincent's Hospital, Sydney, Australia
| | - Markus J Seibel
- Bone Research Program, ANZAC Research Institute, The University of Sydney, Sydney, Australia
| | - John A Eisman
- Osteoporosis and Bone Biology Program and Clinical School, St. Vincent's Hospital, Sydney, Australia; Clinical Translation and Advanced Education, Garvan Institute of Medical Research, Sydney, Australia; School of Medicine, Sydney, University of Notre Dame Australia, Sydney, Australia
| | - Mark M Kushnir
- ARUP Institute for Clinical and Experimental Pathology and Department of Pathology, University of Utah School of Medicine, Salt Lake City, UT
| | - Alan L Rockwood
- ARUP Institute for Clinical and Experimental Pathology and Department of Pathology, University of Utah School of Medicine, Salt Lake City, UT
| | - Tuan V Nguyen
- Osteoporosis and Bone Biology Program and School of Public Health and Community Medicine, University of New South Wales, Sydney, Australia; Centre for Health Technologies, University of Technology, Sydney, Australia.
| |
Collapse
|
35
|
Qi BL, Liu P, Wang QY, Cai WJ, Yuan BF, Feng YQ. Derivatization for liquid chromatography-mass spectrometry. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.03.013] [Citation(s) in RCA: 155] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
36
|
Søeborg T, Frederiksen H, Mouritsen A, Johannsen TH, Main KM, Jørgensen N, Petersen JH, Andersson AM, Juul A. Sex, age, pubertal development and use of oral contraceptives in relation to serum concentrations of DHEA, DHEAS, 17α-hydroxyprogesterone, Δ4-androstenedione, testosterone and their ratios in children, adolescents and young adults. Clin Chim Acta 2014; 437:6-13. [PMID: 24976611 DOI: 10.1016/j.cca.2014.06.018] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2014] [Revised: 06/19/2014] [Accepted: 06/19/2014] [Indexed: 12/11/2022]
Abstract
The influence of sex, age, pubertal development and oral contraceptives on dehydroepiandrosterone (DHEA), DHEA sulfate (DHEAS), 17α-hydroxyprogesterone (17-OHP), Δ4-androstenedione (Adione), testosterone (T), calculated free testosterone (fT), free androgen index (FAI) and selected ratios in 1798 serum samples from healthy children, adolescents and young adults was evaluated. Samples were analyzed by Turboflow-LC-MS/MS. Sex hormone-binding globulin was analyzed by immunoassay. All steroid metabolite concentrations were positively associated with age and pubertal development in both sexes and generally higher in males than in females except for Adione. The pubertal rise in T in males was more pronounced compared to females, reflecting contribution from the testes. Ratios between steroid metabolites varied and depended on sex and age. All ratios were lower during infancy compared to later in life. Use of oral contraceptives significantly lowered serum concentrations of all steroid metabolites, fT, FAI, the 17-OHP/Adione, the Adione/T and the DHEA/Adione ratios, but not the DHEA/DHEAS ratio. We provide reference ranges for DHEA, DHEAS, 17-OHP, Adione, T, fT, FAI and selected ratios in relation to sex, age and pubertal development. Use of oral contraceptives strongly influences adrenal steroidogenesis and should be considered when diagnosing and monitoring treatment of patients with disorders of sex development.
Collapse
Affiliation(s)
- Tue Søeborg
- Department of Growth and Reproduction, Rigshospitalet, Copenhagen University Hospital, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark.
| | - Hanne Frederiksen
- Department of Growth and Reproduction, Rigshospitalet, Copenhagen University Hospital, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Annette Mouritsen
- Department of Growth and Reproduction, Rigshospitalet, Copenhagen University Hospital, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Trine Holm Johannsen
- Department of Growth and Reproduction, Rigshospitalet, Copenhagen University Hospital, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Katharina Maria Main
- Department of Growth and Reproduction, Rigshospitalet, Copenhagen University Hospital, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Niels Jørgensen
- Department of Growth and Reproduction, Rigshospitalet, Copenhagen University Hospital, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Jørgen Holm Petersen
- Department of Growth and Reproduction, Rigshospitalet, Copenhagen University Hospital, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Anna-Maria Andersson
- Department of Growth and Reproduction, Rigshospitalet, Copenhagen University Hospital, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| | - Anders Juul
- Department of Growth and Reproduction, Rigshospitalet, Copenhagen University Hospital, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark
| |
Collapse
|
37
|
Ericsson M, Fallahsharoudi A, Bergquist J, Kushnir MM, Jensen P. Domestication effects on behavioural and hormonal responses to acute stress in chickens. Physiol Behav 2014; 133:161-9. [DOI: 10.1016/j.physbeh.2014.05.024] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Revised: 04/28/2014] [Accepted: 05/20/2014] [Indexed: 10/25/2022]
|
38
|
|
39
|
Separation of steroid isomers by ion mobility mass spectrometry. J Chromatogr A 2013; 1310:133-7. [DOI: 10.1016/j.chroma.2013.08.056] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2013] [Revised: 08/13/2013] [Accepted: 08/15/2013] [Indexed: 11/18/2022]
|
40
|
Fanelli F, Gambineri A, Mezzullo M, Vicennati V, Pelusi C, Pasquali R, Pagotto U. Revisiting hyper- and hypo-androgenism by tandem mass spectrometry. Rev Endocr Metab Disord 2013; 14:185-205. [PMID: 23619762 DOI: 10.1007/s11154-013-9243-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Modern endocrinology is living a critical age of transition as far as laboratory testing and biochemical diagnosis are concerned. Novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays for steroid measurement in biological fluids have abundantly demonstrated their analytical superiority over immunometric platforms that until now have dominated the world of steroid hormones determination in clinical laboratories. One of the most useful applications of LC-MS/MS is in the hypogonadism and hyperandrogenism field: LC-MS/MS has proved particularly suitable for the detection of low levels of testosterone typical of women and children, and in general more reliable in accurately determining hypogonadal male levels. This technique also offers increased informative power by allowing multi-analytical profiles that give a more comprehensive picture of the overall hormonal asset. Several LC-MS/MS methods for testosterone have been published in the last decade, some of them included other androgen or more comprehensive steroid profiles. LC-MS/MS offers the concrete possibility of achieving a definitive standardization of testosterone measurements and the generation of widely accepted reference intervals, that will set the basis for a consensus on the diagnostic value of biochemical testing. The present review is aimed at summarizing technological advancements in androgen measurements in serum and saliva. We also provide a picture of the state of advancement of standardization of testosterone assays, of the redefinition of androgen reference intervals by novel assays and of studies using LC-MS/MS for the characterization and diagnosis of female hyperandrogenism and male hypogonadism.
Collapse
Affiliation(s)
- Flaminia Fanelli
- Endocrinology Unit, Department of Medical and Surgical Sciences, and Center for Applied Biomedical Sciences, S.Orsola - Malpighi Hospital, University Alma Mater Studiorum, Via Massarenti 9, 40138, Bologna, Italy
| | | | | | | | | | | | | |
Collapse
|
41
|
Chen Z, Li J, Zhang J, Xing X, Gao W, Lu Z, Deng H. Simultaneous determination of hair cortisol, cortisone and DHEAS with liquid chromatography–electrospray ionization-tandem mass spectrometry in negative mode. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 929:187-94. [DOI: 10.1016/j.jchromb.2013.04.026] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Revised: 04/18/2013] [Accepted: 04/19/2013] [Indexed: 11/30/2022]
|
42
|
Rhea JM, French D, Molinaro RJ. Direct total and free testosterone measurement by liquid chromatography tandem mass spectrometry across two different platforms. Clin Biochem 2013; 46:656-64. [DOI: 10.1016/j.clinbiochem.2013.01.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2012] [Revised: 01/11/2013] [Accepted: 01/12/2013] [Indexed: 10/27/2022]
|
43
|
Kyriakopoulou L, Yazdanpanah M, Colantonio D, Chan M, Daly C, Adeli K. A sensitive and rapid mass spectrometric method for the simultaneous measurement of eight steroid hormones and CALIPER pediatric reference intervals. Clin Biochem 2013; 46:642-51. [DOI: 10.1016/j.clinbiochem.2013.01.002] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2012] [Revised: 01/04/2013] [Accepted: 01/07/2013] [Indexed: 10/27/2022]
|
44
|
Serum concentrations of DHEA, DHEAS, 17α-hydroxyprogesterone, Δ4-androstenedione and testosterone in children determined by TurboFlow-LC–MS/MS. Clin Chim Acta 2013; 419:95-101. [DOI: 10.1016/j.cca.2013.01.019] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2012] [Revised: 01/21/2013] [Accepted: 01/28/2013] [Indexed: 11/22/2022]
|
45
|
Abdel-Khalik J, Björklund E, Hansen M. Simultaneous determination of endogenous steroid hormones in human and animal plasma and serum by liquid or gas chromatography coupled to tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 928:58-77. [PMID: 23598050 DOI: 10.1016/j.jchromb.2013.03.013] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2012] [Revised: 03/05/2013] [Accepted: 03/13/2013] [Indexed: 01/20/2023]
Abstract
Analytical methodologies based on liquid or gas chromatography coupled to tandem mass spectrometry for the simultaneous determination of two or more endogenous steroid hormones in human and animal plasma and serum has received increased attention the last few years. Especially in the clinical setting steroid profiling is of major importance in disease diagnostics. This paper discusses recent findings in such multi-steroid hormone procedures published from 2001 to 2012. The aim was to elucidate possible relationships between chosen analytical technique and the obtained analyte sensitivity for endogenous steroid hormones. By evaluating the success, at which the currently applied techniques have been utilized, more general knowledge on the field is provided. Furthermore the evaluation provides directions in which future studies may be interesting to conduct.
Collapse
Affiliation(s)
- Jonas Abdel-Khalik
- Toxicology Laboratory, Analytical Biosciences, Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, DK-2100 Copenhagen, Denmark.
| | | | | |
Collapse
|
46
|
Haring R, Wallaschofski H, Teumer A, Kroemer H, Taylor AE, Shackleton CHL, Nauck M, Völker U, Homuth G, Arlt W. A SULT2A1 genetic variant identified by GWAS as associated with low serum DHEAS does not impact on the actual DHEA/DHEAS ratio. J Mol Endocrinol 2013; 50:73-7. [PMID: 23132913 PMCID: PMC3535724 DOI: 10.1530/jme-12-0185] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
DHEA is the major precursor of human sex steroid synthesis and is inactivated via sulfonation to DHEAS. A previous genome-wide association study related the single nucleotide polymorphism (SNP) rs2637125, located near the coding region of DHEA sulfotransferase, SULT2A1, to serum DHEAS concentrations. However, the functional relevance of this SNP with regard to DHEA sulfonation is unknown. Using data from 3300 participants of the population-based cohort Study of Health in Pomerania, we identified 43 individuals being homozygote for the minor allele of the SNP rs2637125 (AA) and selected two sex- and age-matched individuals with AG and GG genotype (n=172) respectively. Steroid analysis including measurement of serum DHEA and DHEAS was carried out by liquid chromatography/mass spectrometry, employing steroid oxime analysis for enhancing the sensitivity of DHEA detection. We applied quantile regression models to compare median hormone levels across SULT2A1 genotypes. Median comparisons by SULT2A1 genotype (AA vs AG and GG genotypes respectively) showed no differences in the considered hormones including DHEAS, DHEA, androstenedione, as well as cortisol and cortisone concentrations. SULT2A1 genotype also had no effect on the DHEA/DHEAS ratio. Sex-stratified analyses, as well as alternative use of the SULT2A1 SNP rs182420, yielded similar negative results. Genetic variants of SULT2A1 do not appear to have an effect on individual DHEA and DHEAS concentrations or the DHEA/DHEAS ratio as a marker of DHEA sulfonation capacity.
Collapse
Affiliation(s)
- Robin Haring
- Institute of Clinical Chemistry and Laboratory Medicine, University Medicine Greifswald, 17475 Greifswald, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Abstract
Mass spectrometry methods have the potential to measure different hormones during the same analysis and have improved specificity and a wide analytical range compared with many immunoassay methods. Increasingly in clinical laboratories liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays are replacing immunoassays for the routine measurement of testosterone, 17-hydroxyprogesterone, and other steroid hormones. Reference LC-MS/MS methods for steroid, thyroid, and peptide hormones are being used for assessment of the performance and calibration of commercial immunoassays. In this chapter, the general principles of tandem mass spectrometry and examples of hormone assays are described.
Collapse
Affiliation(s)
- Helen P Field
- Department of Specialist Laboratory Medicine, St. James's University Hospital, Leeds, UK
| |
Collapse
|
48
|
Athanasiadou I, Angelis YS, Lyris E, Georgakopoulos C, Athanasiadou I, Georgakopoulos C. Chemical derivatization to enhance ionization of anabolic steroids in LC-MS for doping-control analysis. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2012.10.003] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
49
|
Star-Weinstock M, Williamson BL, Dey S, Pillai S, Purkayastha S. LC-ESI-MS/MS Analysis of Testosterone at Sub-Picogram Levels Using a Novel Derivatization Reagent. Anal Chem 2012; 84:9310-7. [DOI: 10.1021/ac302036r] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Michal Star-Weinstock
- AB SCIEX, Chemistry and Consumables R&D, 500 Old Connecticut Path, Framingham, Massachusetts 01701, United States
| | - Brian L. Williamson
- AB SCIEX, Chemistry and Consumables R&D, 500 Old Connecticut Path, Framingham, Massachusetts 01701, United States
| | - Subhakar Dey
- AB SCIEX, Chemistry and Consumables R&D, 500 Old Connecticut Path, Framingham, Massachusetts 01701, United States
| | - Sasi Pillai
- AB SCIEX, Chemistry and Consumables R&D, 500 Old Connecticut Path, Framingham, Massachusetts 01701, United States
| | - Subhasish Purkayastha
- AB SCIEX, Chemistry and Consumables R&D, 500 Old Connecticut Path, Framingham, Massachusetts 01701, United States
| |
Collapse
|
50
|
Kushnir MM, Naessén T, Wanggren K, Rockwood AL, Crockett DK, Bergquist J. Protein and steroid profiles in follicular fluid after ovarian hyperstimulation as potential biomarkers of IVF outcome. J Proteome Res 2012; 11:5090-100. [PMID: 22988950 DOI: 10.1021/pr300535g] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Controlled ovarian hyperstimulation is performed to assist with generation of multiple mature oocytes for use in in vitro fertilization (IVF). The goal of our study was to evaluate differences in protein and steroid profiles in ovarian follicular fluid (hFF) samples obtained during oocyte retrieval from women undergoing IVF treatment and to identify physiological pathways associated with the proteins. The hFF samples were depleted of abundant proteins, fractionated by ultrafiltration, digested, and analyzed by nano-LC-QTOF. Concentrations of 15 endogenous steroids were determined in the samples using LC-MS/MS methods. The total number of proteins identified in the samples was 75, of which 4, 7, and 2 were unique to the samples from women with viable pregnancy, miscarriage, and no pregnancy, respectively. Identified proteins were associated with the acute response signaling, coagulation system, intrinsic and extrinsic prothrombin activation, complement system, neuroprotective role of THOP1, FXR/RXR activation, role of tissue factor, and growth hormone pathways. A greater number of proteins associated with biosynthesis was found in hFF samples corresponding to the oocytes resulting in pregnancy. The abundance of seven proteins was found to be associated with steroidogenesis. The obtained data will contribute to better understanding of the pathogenesis and development of noninvasive markers for assessment of oocytes viability.
Collapse
Affiliation(s)
- Mark M Kushnir
- ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, Utah 84108, United States.
| | | | | | | | | | | |
Collapse
|