1
|
Personalized diagnosis in suspected myocardial infarction. Clin Res Cardiol 2023; 112:1288-1301. [PMID: 37131096 PMCID: PMC10449973 DOI: 10.1007/s00392-023-02206-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 04/11/2023] [Indexed: 05/04/2023]
Abstract
BACKGROUND In suspected myocardial infarction (MI), guidelines recommend using high-sensitivity cardiac troponin (hs-cTn)-based approaches. These require fixed assay-specific thresholds and timepoints, without directly integrating clinical information. Using machine-learning techniques including hs-cTn and clinical routine variables, we aimed to build a digital tool to directly estimate the individual probability of MI, allowing for numerous hs-cTn assays. METHODS In 2,575 patients presenting to the emergency department with suspected MI, two ensembles of machine-learning models using single or serial concentrations of six different hs-cTn assays were derived to estimate the individual MI probability (ARTEMIS model). Discriminative performance of the models was assessed using area under the receiver operating characteristic curve (AUC) and logLoss. Model performance was validated in an external cohort with 1688 patients and tested for global generalizability in 13 international cohorts with 23,411 patients. RESULTS Eleven routinely available variables including age, sex, cardiovascular risk factors, electrocardiography, and hs-cTn were included in the ARTEMIS models. In the validation and generalization cohorts, excellent discriminative performance was confirmed, superior to hs-cTn only. For the serial hs-cTn measurement model, AUC ranged from 0.92 to 0.98. Good calibration was observed. Using a single hs-cTn measurement, the ARTEMIS model allowed direct rule-out of MI with very high and similar safety but up to tripled efficiency compared to the guideline-recommended strategy. CONCLUSION We developed and validated diagnostic models to accurately estimate the individual probability of MI, which allow for variable hs-cTn use and flexible timing of resampling. Their digital application may provide rapid, safe and efficient personalized patient care. TRIAL REGISTRATION NUMBERS Data of following cohorts were used for this project: BACC ( www. CLINICALTRIALS gov ; NCT02355457), stenoCardia ( www. CLINICALTRIALS gov ; NCT03227159), ADAPT-BSN ( www.australianclinicaltrials.gov.au ; ACTRN12611001069943), IMPACT ( www.australianclinicaltrials.gov.au , ACTRN12611000206921), ADAPT-RCT ( www.anzctr.org.au ; ANZCTR12610000766011), EDACS-RCT ( www.anzctr.org.au ; ANZCTR12613000745741); DROP-ACS ( https://www.umin.ac.jp , UMIN000030668); High-STEACS ( www. CLINICALTRIALS gov ; NCT01852123), LUND ( www. CLINICALTRIALS gov ; NCT05484544), RAPID-CPU ( www. CLINICALTRIALS gov ; NCT03111862), ROMI ( www. CLINICALTRIALS gov ; NCT01994577), SAMIE ( https://anzctr.org.au ; ACTRN12621000053820), SEIGE and SAFETY ( www. CLINICALTRIALS gov ; NCT04772157), STOP-CP ( www. CLINICALTRIALS gov ; NCT02984436), UTROPIA ( www. CLINICALTRIALS gov ; NCT02060760).
Collapse
|
2
|
Clinical presentation and angiographic findings of acute myocardial infarction in young adults in Jazan region. BMC Cardiovasc Disord 2023; 23:302. [PMID: 37328747 PMCID: PMC10273592 DOI: 10.1186/s12872-023-03335-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 06/06/2023] [Indexed: 06/18/2023] Open
Abstract
BACKGROUND There is a paucity of information about the clinical features and angiographic findings in young patients with acute myocardial infarction (MI), especially in the Arab Peninsula countries. OBJECTIVE The aim of this study was to assess the proposed risk factors, clinical presentation, and angiographic findings of acute myocardial infarction in young adults. METHODS This prospective study included young (range, 18 to 45 years) patients who presented with acute MI based on clinical evaluation, laboratory investigation, and electrocardiogram, and they underwent a coronary angiography procedure. KEY FINDINGS Data of 109 patients with a diagnosis of acute MI were collected. Patients' mean age was 39.98 ± 7.52 years (range, 31 to 45 years), and 92.7% (101) were male. Smoking was the highest risk factor in 67% of patients, obesity and overweight in 66%, sedentary lifestyle in 64%, dyslipidaemia in 33%, and hypertension in 28%. Smoking was the most common risk factor for acute MI in males (p = 0.009), whereas sedentary lifestyle was the most common risk factor in females (p = 0.028). Chest pain typical of acute MI was the most common presenting symptom in 96% of patients (p < 0.001). On admission, 96% of patients were conscious, and 95% were oriented. On angiography, the left anterior descending artery (LAD) was affected in 57%, the right coronary artery (RCA) was affected in 42%, and the left circumflex artery (LCX) was affected in 32% of patients. The LAD was severely affected in 44%, the RCA was severely affected in 25.7%, and the LCX was severely affected in 19.26% of patients (p < 0.001). CONCLUSION Smoking, obesity, sedentary lifestyle, dyslipidaemia, and hypertension were the most common risk factors for acute MI. Smoking was the most common risk factor in males and sedentary lifestyle in females. The LAD was the most commonly affected coronary artery, followed by the RCA and LCX arteries, with the same order for severity of stenosis.
Collapse
|
3
|
Rising and Falling High-Sensitivity Cardiac Troponin in Diagnostic Algorithms for Patients With Suspected Myocardial Infarction. J Am Heart Assoc 2023; 12:e027166. [PMID: 37158171 DOI: 10.1161/jaha.122.027166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Background High-sensitivity cardiac troponin (hs-cTn)-based diagnostic algorithms are recommended for the management of patients with suspected myocardial infarction (MI) without ST elevation. Although mirroring different phases of myocardial injury, falling and rising troponin patterns (FPs and RPs, respectively) are equally considered by most algorithms. We aimed to compare the performance of diagnostic protocols for RPs and FPs, separately. Methods and Results We pooled 2 prospective cohorts of patients with suspected MI and stratified patients to stable, FP, and RP during serial sampling separately for hs-cTnI and hs-cTnT and applied the European Society of Cardiology 0/1- and 0/3-hour algorithms comparing the positive predictive values to rule in MI. Overall, 3523 patients were included in the hs-cTnI study population. The positive predictive value for patients with an FP was significantly reduced compared with patients with an RP (0/1-hour: FP, 53.3% [95% CI, 45.0-61.4] versus RP, 76.9 [95% CI, 71.6-81.7]; 0/3-hour: FP, 56.9% [95% CI, 42.2-70.7] versus RP, 78.1% [95% CI, 74.0-81.8]). The proportion of patients in the observe zone was larger in the FP using 0/1-hour (31.3% versus 55.8%) and 0/3-hour (14.6% versus 38.6%) algorithms. Alternative cutoffs did not improve algorithm performances. Compared with stable hs-cTn, the risk for death or MI was highest in those with an FP (adjusted hazard ratio [HR], hs-cTnI 2.3 [95% CI, 1.7-3.2]; RP adjusted HR, hs-cTnI 1.8 [95% CI, 1.4-2.4]). Findings were similar for hs-cTnT tested in 3647 patients overall. Conclusions The positive predictive value to rule in MI by the European Society of Cardiology 0/1- and 0/3-hour algorithms is significantly lower in patients with FP than RP. These are at highest risk for incident death or MI. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT02355457, NCT03227159.
Collapse
|
4
|
Role of Copeptin and hs-cTnT to Discriminate AHF from Uncomplicated NSTE-ACS with Baseline Elevated hs-cTnT-A Derivation and External Validation Study. Cells 2023; 12:1062. [PMID: 37048135 PMCID: PMC10092967 DOI: 10.3390/cells12071062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 03/23/2023] [Accepted: 03/28/2023] [Indexed: 04/03/2023] Open
Abstract
BACKGROUND In light of overlapping symptoms, discrimination between non-ST-elevation (NSTE) acute coronary syndrome (ACS) and acute heart failure (HF) is challenging, particularly in patients with equivocal clinical presentation for suspected ACS. We sought to evaluate the diagnostic and prognostic properties of copeptin in this scenario. METHODS Data from 1088 patients from a single-center observational registry were used to test the ability of serial high sensitivity cardiac troponin T (hs-cTnT)-compared to copeptin, or a combination of copeptin with hs-cTnT-to discriminate acute HF from uncomplicated non-ST-elevation myocardial infarction (NSTEMI) and to evaluate all-cause mortality after 365 days. Patients with STEMI, those with unstable angina and either normal or undetectable hs-cTnT concentrations were excluded. The findings were validated in an independent external NSTE-ACS cohort. RESULTS A total of 219 patients were included in the analysis. The final diagnosis was acute HF in 56 and NSTE-ACS in 163, with NSTEMI in 78 and unstable angina having stable elevation of hs-cTnT >ULN in 85. The rate of all-cause death at 1 year was 9.6% and occurred significantly more often in acute HF than in NSTE-ACS (15 vs. 6%, p < 0.001). In the test cohort, the area under the receiver operator curve (AUC) for the discrimination of acute HF vs. NSTE-ACS without HF was 0.725 (95% confidence interval [CI] 0.625-0.798) for copeptin and significantly higher than for hs-cTnT at 0 h (AUC = 0.460, 0.370-0.550) or at 3 h (AUC = 0.441, 0.343-0.538). Copeptin and hs-cTnT used either as continuous values or at cutoffs optimized to yield 90% specificity for acute HF were associated with significantly higher age- and sex-adjusted risk for all-cause mortality at 365 days. The findings from the test cohort were consistently replicated in the independent external NSTE-ACS validation cohort. CONCLUSIONS High concentrations of copeptin in patients with suspected NSTE-ACS and equivocal clinical presentation suggest the presence of acute HF compared to uncomplicated NSTE-ACS and are associated with higher rates of all-cause death at 365 days.
Collapse
|
5
|
In-Vitro Diagnostic Reagent Evaluation of Commercially Available Cardiac Troponin I Assay Kits Using H/D Exchange Mass Spectrometry for Antibody-Epitope Mapping. Anal Chem 2023; 95:2278-2284. [PMID: 36647798 DOI: 10.1021/acs.analchem.2c03946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Cardiac troponin I (cTnI) is the biomarker of choice and considered a gold standard for the diagnosis of acute myocardial infarction. However, the quantitative results of cTnI assay kits from different manufacturers are not comparable. Based on the H/D exchange mass spectrometry (HDX-MS) workflow, we developed an in-vitro diagnostic reagent antibody evaluation strategy to analyze the interactions of epitopes and antibody cocktails─(R195, F12, S13) and (D1, D2, pAb2). The HDX results indicate that the quantitative result bias of the different reagents originates from the ability of antibodies to recognize various cTnI complex forms, such as free cTnI, hydrolyzed cTnI, and cTnI combined with cTnT or TnC as binary or ternary complexes (cTnIC, cTnTIC), in blood based on different epitopes. The data obtained from the peptide HDX of interest after treatment with various antibody cocktails clearly indicated epitope specificity. The consistency of quantitative results can be improved by a thorough investigation into the epitopes recognized by the antibodies of various diagnostic kits, which will lead to the standardization of cTnI diagnosis.
Collapse
|
6
|
Leveraging Machine Learning Techniques to Forecast Chronic Total Occlusion before Coronary Angiography. J Clin Med 2022; 11:jcm11236993. [PMID: 36498568 PMCID: PMC9739483 DOI: 10.3390/jcm11236993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 11/17/2022] [Accepted: 11/24/2022] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Chronic total occlusion (CTO) remains the most challenging procedure in coronary artery disease (CAD) for interventional cardiology. Although some clinical risk factors for CAD have been identified, there is no personalized prognosis test available to confidently identify patients at high or low risk for CTO CAD. This investigation aimed to use a machine learning algorithm for clinical features from clinical routine to develop a precision medicine tool to predict CTO before CAG. METHODS Data from 1473 CAD patients were obtained, including 1105 in the training cohort and 368 in the testing cohort. The baseline clinical characteristics were collected. Univariate and multivariate logistic regression analyses were conducted to identify independent risk factors that impact the diagnosis of CTO. A CTO predicting model was established and validated based on the independent predictors using a machine learning algorithm. The area under the curve (AUC) was used to evaluate the model. RESULTS The CTO prediction model was developed with the training cohort using the machine learning algorithm. Eight variables were confirmed as 'important': gender (male), neutrophil percentage (NE%), hematocrit (HCT), total cholesterol (TC), high-density lipoprotein cholesterol (HDL), ejection fraction (EF), troponin I (TnI), and N-terminal pro-B-type natriuretic peptide (NT-proBNP). The model achieved good concordance indices of 0.724 and 0.719 in the training and testing cohorts, respectively. CONCLUSIONS An easy-to-use tool to predict CTO in patients with CAD was developed and validated. More research with larger cohorts are warranted to improve the prediction model, which can support clinician decisions on the early discerning CTO in CAD patients.
Collapse
|
7
|
High-sensitivity troponin I with or without ultra-sensitive copeptin for the instant rule-out of acute myocardial infarction. Front Cardiovasc Med 2022; 9:895421. [PMID: 36017085 PMCID: PMC9395923 DOI: 10.3389/fcvm.2022.895421] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Accepted: 07/26/2022] [Indexed: 12/26/2022] Open
Abstract
Background The instant, single-sampling rule-out of acute myocardial infarction (AMI) is still an unmet clinical need. We aimed at testing and comparing diagnostic performance and prognostic value of two different single-sampling biomarker strategies for the instant rule-out of AMI. Methods From the Biomarkers in Acute Cardiac Care (BACC) cohort, we recruited consecutive patients with acute chest pain and suspected AMI presenting to the Emergency Department of the University Medical Center Hamburg-Eppendorf, Hamburg, Germany. We compared safety, effectiveness and 12-month incidence of the composite endpoint of all-cause death and myocardial infarction between (i) a single-sampling, dual-marker pathway combining high-sensitivity cardiac troponin I (hs-cTnI) and ultra-sensitive copeptin (us-Cop) at presentation (hs-cTnI ≤ 27 ng/L, us-Cop < 10 pmol/L and low-risk ECG) and (ii) a single-sampling pathway based on one-off hs-cTnI determination at presentation (hs-cTnI < 5 ng/L and low-risk ECG). As a comparator, we used the European Society of Cardiology (ESC) 0/1-h dual-sampling algorithm. Results We enrolled 1,136 patients (male gender 65%) with median age of 64 years (interquartile range, 51–75). Overall, 228 (20%) patients received a final diagnosis of AMI. The two single-sampling instant rule-out pathways yielded similar negative predictive value (NPV): 97.4% (95%CI: 95.4–98.7) and 98.7% (95%CI: 96.9–99.6) for dual-marker and single hs-cTnI algorithms, respectively (P = 0.11). Both strategies were comparably safe as the ESC 0/1-h dual-sampling algorithm and this was consistent across subgroups of early-comers, low-intermediate risk (GRACE-score < 140) and renal dysfunction. Despite a numerically higher rate of false-negative results, the dual-marker strategy ruled-out a slightly but significantly higher percentage of patients compared with single hs-cTnI determination (37.4% versus 32.9%; P < 0.001). There were no significant between-group differences in 12-month composite outcome. Conclusions Instant rule-out pathways based on one-off determination of hs-cTnI alone or in combination with us-Cop are comparably safe as the ESC 0/1 h algorithm for the instant rule-out of AMI, yielding similar prognostic information. Instant rule-out strategies are safe alternatives to the ESC 0/1 h algorithm and allow the rapid and effective triage of suspected AMI in patients with low-risk ECG. However, adding copeptin to hs-cTn does not improve the safety of instant rule-out compared with the single rule-out hs-cTn at very low cut-off concentrations.
Collapse
|
8
|
High-Sensitivity Troponin T Testing for Pediatric Patients in the Emergency Department. Pediatr Cardiol 2022; 43:350-359. [PMID: 34787696 DOI: 10.1007/s00246-021-02726-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/01/2021] [Indexed: 01/19/2023]
Abstract
Debate exists on the usefulness of high-sensitivity cardiac troponin (hs-cTn) testing in pediatric patients due to the perceived low incidence of myocardial injury and lack of data concerning its efficacy. We evaluated the contribution of an increased hs-cTnT above the 99th percentile upper-reference limit (URL) to clinical diagnoses made in pediatric patients presenting to the emergency department (ED). Retrospective cohort study including patients aged 0-18 years presenting to the ED from 2018 to 2020 where hs-cTnT was measured. Sex-specific 99th percentile URLs of 15 and 10 ng/L for males and females, respectively, were used, with concentrations above these thresholds considered indicative of myocardial injury. Overall, 356 patients were identified in whom hs-cTnT concentrations were measured during ED clinical evaluation. Hs-cTnT was increased above the 99th percentile on presentation in 36 patients (10.1%). Twelve patients (3.4%) had a clinical cardiac diagnosis made. Hs-cTnT was increased in 6 of these (50.0%). Serial hs-cTnT from 106 patients with an initial hs-cTnT < 99th percentile was subsequently elevated in 5 (4.6%); none of whom had a final clinical cardiac diagnosis. Hs-cTnT has high specificity, but low sensitivity when used as a screening tool for myocardial injury when the gold standard is mostly clinical assessment. In present practice, however, they do not appear to track well with clinical diagnoses. Further studies are needed to more clearly define the role of hs-cTnT in this patient population.
Collapse
|
9
|
Implementation of an early rule-out pathway for myocardial infarction using a high-sensitivity cardiac troponin T assay. Open Heart 2021; 8:e001769. [PMID: 34824100 PMCID: PMC8627412 DOI: 10.1136/openhrt-2021-001769] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 10/25/2021] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVES Patients with suspected acute coronary syndrome and high-sensitivity cardiac troponin (hs-cTn) concentrations below the limit of detection at presentation are low risk. We aim to determine whether implementing this approach facilitates the safe early discharge of patients. METHODS In a prospective single-centre cohort study, consecutive patients with suspected acute coronary syndrome were included before (standard care) and after (intervention) implementation of an early rule-out pathway. During standard care, myocardial infarction was ruled out if hs-cTnT concentrations were <99th centile (14 ng/L) at presentation and at 6-12 hours after symptom onset. In the intervention, patients were ruled out if hs-cTnT concentrations were <5 ng/L at presentation and symptoms present for ≥3 hours or were ≥5 ng/L and unchanged within the reference range at 3 hours. We compared duration of stay (efficacy) and all-cause death at 1 year (safety) before and after implementation. RESULTS We included 10 315 consecutive patients (64±16 years, 46% women) with 6642 (64%) and 3673 (36%) in the standard care and intervention groups, respectively. Duration of stay was reduced from 534 (IQR, 220-2279) to 390 (IQR, 218-1910) min (p<0.001) after implementation. At 1 year, all-cause death occurred in 10.9% (721 of 6642) and 10.4% (381 of 3673) of patients in the standard care group (referent) and intervention group, respectively (adjusted OR 1.02, 95% CI 0.88 to 1.18). CONCLUSION In patients with suspected acute coronary syndrome, implementing an early rule-out pathway using hs-cTnT concentrations <5 ng/L at presentation reduced the duration of stay in hospital without compromising safety.
Collapse
|
10
|
Troponin-Guided Coronary Computed Tomographic Angiography After Exclusion of Myocardial Infarction. J Am Coll Cardiol 2021; 78:1407-1417. [PMID: 34593122 PMCID: PMC8482793 DOI: 10.1016/j.jacc.2021.07.055] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 07/28/2021] [Accepted: 07/29/2021] [Indexed: 12/17/2022]
Abstract
BACKGROUND Patients with suspected acute coronary syndrome in whom myocardial infarction has been excluded are at risk of future adverse cardiac events. OBJECTIVES This study evaluated the usefulness of high-sensitivity cardiac troponin I (hs-cTnI) to select patients for further investigation after myocardial infarction has been excluded. METHODS This is a prospective cohort study of patients presenting to the emergency department with suspected acute coronary syndrome and hs-cTnI concentrations below the sex-specific 99th percentile. Patients were recruited in a 2:1 fashion, stratified by peak hs-cTnI concentration above and below the risk stratification threshold of 5 ng/L. All patients underwent coronary computed tomography angiography (CCTA) after hospital discharge. RESULTS Overall, 250 patients were recruited (61.4 ± 12.2 years 31% women) in whom 62.4% (156 of 250 patients) had coronary artery disease (CAD). Patients with intermediate hs-cTnI concentrations (between 5 ng/L and the sex-specific 99th percentile) were more likely to have CAD than those with hs-cTnI concentrations <5 ng/L (71.9% [120 of 167 patients] vs 43.4% [36 of 83 patients]; odds ratio: 3.33; 95% CI: 1.92-5.78). Conversely, there was no association between anginal symptoms and CAD (63.2% [67 of 106 patients] vs 61.8% [89 of 144 patients]; odds ratio: 0.92; 95% CI: 0.48-1.76). Most patients with CAD did not have a previous diagnosis (53.2%; 83 of 156 patients) and were not on antiplatelet and statin therapies (63.5%; 99 of 156 patients) before they underwent CCTA. CONCLUSIONS In patients who had myocardial infarction excluded, CAD was 3× more likely in those with intermediate hs-cTnI concentrations compared with low hs-cTnI concentrations. In such patients, CCTA could help to identify those with occult CAD and to target preventative treatments, thereby improving clinical outcomes.
Collapse
|
11
|
A Biomarker Model to Distinguish Types of Myocardial Infarction and Injury. J Am Coll Cardiol 2021; 78:781-790. [PMID: 34412811 DOI: 10.1016/j.jacc.2021.06.027] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 06/07/2021] [Accepted: 06/09/2021] [Indexed: 02/06/2023]
Abstract
BACKGROUND Discrimination among patients with type 1 myocardial infarction (T1MI), type 2 myocardial infarction (T2MI), and myocardial injury is difficult. OBJECTIVES The aim of this study was to investigate the discriminative value of a 29-biomarker panel in an emergency department setting. METHODS Patients presenting with suspected myocardial infarction (MI) were recruited. The final diagnosis in all patients was adjudicated on the basis of the fourth universal definition of MI. A panel of 29 biomarkers was measured, and multivariable logistic regression analysis was used to evaluate the associations of these biomarkers with the diagnosis of MI or myocardial injury. Biomarkers were chosen using backward selection. The model was internally validated using bootstrapping. RESULTS Overall, 748 patients were recruited (median age 64 years), of whom 138 had MI (107 T1MI and 31 T2MI) and 221 had myocardial injury. In the multivariable model, 4 biomarkers (apolipoprotein A-II, N-terminal prohormone of brain natriuretic peptide, copeptin, and high-sensitivity cardiac troponin I) remained significant discriminators between T1MI and T2MI. Internal validation of the model showed an area under the curve of 0.82. For discrimination between MI and myocardial injury, 6 biomarkers (adiponectin, N-terminal prohormone of brain natriuretic peptide, pulmonary and activation-regulated chemokine, transthyretin, copeptin, and high-sensitivity troponin I) were selected. Internal validation showed an area under the curve of 0.84. CONCLUSIONS Among 29 biomarkers, 7 were identified to be the most relevant discriminators between subtypes of MI or myocardial injury. Regression models based on these biomarkers allowed good discrimination. (Biomarkers in Acute Cardiac Care [BACC]; NCT02355457).
Collapse
|
12
|
The association of anaemia and high-sensitivity cardiac troponin and its effect on diagnosing myocardial infarction. EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE 2021; 10:1187-1196. [PMID: 34350455 DOI: 10.1093/ehjacc/zuab066] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 05/13/2021] [Accepted: 07/20/2021] [Indexed: 11/14/2022]
Abstract
AIMS Anaemia is common in patients with acute myocardial infarction (MI). We investigated the association of high-sensitivity cardiac troponin (hs-cTn) and haemoglobin (Hb) and the influence of anaemia on the performance of diagnostic protocols for suspected MI. METHODS AND RESULTS Patients with suspected MI were consecutively enrolled at a tertiary centre. Final diagnoses were independently adjudicated by two cardiologists. Performance measures of hs-cTn-based algorithms were compared for anaemic and non-anaemic patients (Hb <12 g/dL in women and <13 g/dL in men). The influence of anaemia on survival (median follow-up 1.7 years) was investigated using multivariable cox-regression analysis and the association of Hb and hs-cTn by multivariable linear regression analysis. Overall, 2223 patients were included, of whom 415 (18.7%) had anaemia. In anaemic patients, the incidence of MI was similar; however, chronic myocardial injury was significantly more prevalent (20.1% vs. 48.2%). The negative predictive value to rule-out MI was similar for both algorithms and all assays in patients with anaemia, although the positive predictive value to rule-in MI was partly reduced for the 0/3-h algorithm. Fewer anaemic patients were triaged after 1 h. Anaemia was an independent predictor of death. Adjusted for patient characteristics, Hb was significantly associated with hs-cTn. By providing a point-based tool, the Hb-associated hs-cTn concentration and thus chronic myocardial injury may be predicted. CONCLUSION Anaemia partly affects the rule-in, but not the rule-out of MI in hs-cTn-based diagnostic protocols. Hs-cTn concentrations and thus chronic myocardial injury may be predicted by clinical variables and Hb. TRIAL REGISTRATION clinicaltrials.gov (NCT02355457 and NCT03227159).
Collapse
|
13
|
Diagnostic Validation of a High-Sensitivity Cardiac Troponin I Assay. Clin Chem 2021; 67:1230-1239. [PMID: 34254126 DOI: 10.1093/clinchem/hvab070] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 04/30/2021] [Indexed: 01/29/2023]
Abstract
BACKGROUND Emergency departments worldwide are increasingly adopting rapid diagnosis of patients with suspected myocardial infarction (MI) based on high-sensitivity troponin. We set out to assess the diagnostic accuracy of a high-sensitivity cardiac troponin I (hs-cTnI) assay in a prospective study. METHODS In a cohort study including 1800 patients presenting with suspected acute MI, we developed and temporally validated a 0/1 h diagnostic algorithm using the Siemens Atellica IM hs-cTnI assay. The algorithm was established in the first 928 patients and validated in the following 872 patients. RESULTS The derived algorithm consisted of a baseline rule-out of non-ST-segment elevation MI using a cutoff <3 ng/L in patients with symptom onset ≥3 h or an admission troponin I level <6 ng/L with a Δ change of <3 ng/L from 0 h to 1 h. For rule-in, an admission troponin I level ≥120 ng/L or an increase within the first hour ≥12 ng/L was required. Application of the algorithm to the validation cohort showed a negative predictive value of 99.8% (95% CI, 98.7%-100.0%), sensitivity of 99.1% (95% CI, 95.1%-100.0%), and 48.3% of patients ruled out, whereas 15.1% were ruled in with a positive predictive value of 68.0% (95% CI, 59.1%-75.9%) and specificity of 94.4% (95% CI, 92.5%-96.0%). The diagnostic performance was comparable to guideline-recommended application of an established hs-cTnI assay in a rapid 0/1 h strategy. CONCLUSIONS The Siemens hs-cTnI assay is well suited for application in rapid diagnostic stratification of patients with suspected MI. STUDY REGISTRATION www.clinicaltrials.gov (NCT02355457).
Collapse
|
14
|
High-sensitivity troponin assays for early rule-out of acute myocardial infarction in people with acute chest pain: a systematic review and economic evaluation. Health Technol Assess 2021; 25:1-276. [PMID: 34061019 PMCID: PMC8200931 DOI: 10.3310/hta25330] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Early diagnosis of acute myocardial infarction is important, but only 20% of emergency admissions for chest pain will actually have an acute myocardial infarction. High-sensitivity cardiac troponin assays may allow rapid rule out of myocardial infarction and avoid unnecessary hospital admissions. OBJECTIVES To assess the clinical effectiveness and cost-effectiveness of high-sensitivity cardiac troponin assays for the management of adults presenting with acute chest pain, in particular for the early rule-out of acute myocardial infarction. METHODS Sixteen databases were searched up to September 2019. Review methods followed published guidelines. Studies were assessed for quality using appropriate risk-of-bias tools. The bivariate model was used to estimate summary sensitivity and specificity for meta-analyses involving four or more studies; otherwise, random-effects logistic regression was used. The health economic analysis considered the long-term costs and quality-adjusted life-years associated with different troponin testing methods. The de novo model consisted of a decision tree and a state-transition cohort model. A lifetime time horizon (of 60 years) was used. RESULTS Thirty-seven studies (123 publications) were included in the review. The high-sensitivity cardiac troponin test strategies evaluated are defined by the combination of four factors (i.e. assay, number and timing of tests, and threshold concentration), resulting in a large number of possible combinations. Clinical opinion indicated a minimum clinically acceptable sensitivity of 97%. When considering single test strategies, only those using a threshold at or near to the limit of detection for the assay, in a sample taken at presentation, met the minimum clinically acceptable sensitivity criterion. The majority of the multiple test strategies that met this criterion comprised an initial rule-out step, based on high-sensitivity cardiac troponin levels in a sample taken on presentation and a minimum symptom duration, and a second stage for patients not meeting the initial rule-out criteria, based on presentation levels of high-sensitivity cardiac troponin and absolute change after 1, 2 or 3 hours. Two large cluster randomised controlled trials found that implementation of an early rule-out pathway for myocardial infarction reduced length of stay and rate of hospital admission without increasing cardiac events. In the base-case analysis, standard troponin testing was both the most effective and the most costly. Other testing strategies with a sensitivity of 100% (subject to uncertainty) were almost equally effective, resulting in the same life-year and quality-adjusted life-year gain at up to four decimal places. Comparisons based on the next best alternative showed that for willingness-to-pay values below £8455 per quality-adjusted life-year, the Access High Sensitivity Troponin I (Beckman Coulter, Brea, CA, USA) [(symptoms > 3 hours AND < 4 ng/l at 0 hours) OR (< 5 ng/l AND Δ < 5 ng/l at 0 to 2 hours)] would be cost-effective. For thresholds between £8455 and £20,190 per quality-adjusted life-year, the Elecsys® Troponin-T high sensitive (Roche, Basel, Switzerland) (< 12 ng/l at 0 hours AND Δ < 3 ng/l at 0 to 1 hours) would be cost-effective. For a threshold > £20,190 per quality-adjusted life-year, the Dimension Vista® High-Sensitivity Troponin I (Siemens Healthcare, Erlangen, Germany) (< 5 ng/l at 0 hours AND Δ < 2 ng/l at 0 to 1 hours) would be cost-effective. CONCLUSIONS High-sensitivity cardiac troponin testing may be cost-effective compared with standard troponin testing. STUDY REGISTRATION This study is registered as PROSPERO CRD42019154716. FUNDING This project was funded by the National Institute for Health Research (NIHR) Evidence Synthesis programme and will be published in full in Health Technology Assessment; Vol. 25, No. 33. See the NIHR Journals Library website for further project information.
Collapse
|
15
|
CHEST PAIN AND SINGLE TROPONIN. JOURNAL OF CONTEMPORARY MEDICINE 2020. [DOI: 10.16899/jcm.790433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
16
|
Development of a Novel Sensor System Based on Magnetic Microspheres to Detect Cardiac Troponin T. INT J POLYM SCI 2020. [DOI: 10.1155/2020/8855550] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Acute myocardial infarction (AMI) causes irreversible injury to cardiomyocytes in a short time and may result in various complications, severely threatening patient safety. Therefore, it is necessary to predict the possibility of AMI in the prophase. Prognostic detection of biomarkers that specifically reflect myocardial damage in a patient’s blood has become an essential mediating measure to prevent the serious occurrence of AMI. The present study is aimed at exploring a novel sensing system with high specificity and precision based on magnetic microspheres developed to detect cardiac troponin T (cTnT), which is the most specific diagnostic marker for AMI in cardiovascular diseases. Naive human cTnT protein in serum samples and antigens on functional magnetic microspheres will competitively bind with limited specific antibodies. After rapid removal of heterogeneous elements in the sera using a magnetic separator, fluorescein isothiocyanate-labeled immunoglobulin G is added to react with specific antibodies on the magnetic microspheres. Then, a flow cytometer is used to collect signals of different fluorescence intensities. The results show that the method is characterized by economy, high accuracy, and novelty. It can be used for the detection of cTnT in blood at 1.7–106.1 ng/mL, with a detection limit of 0.5 ng/mL. Thus, the proposed sensor improves the accuracy and efficiency of diagnosis before clinical deterioration of AMI.
Collapse
|
17
|
Differences in measurement of high-sensitivity troponin in an on-demand and batch-wise setting. EUROPEAN HEART JOURNAL. ACUTE CARDIOVASCULAR CARE 2020; 10:2048872620924198. [PMID: 32700543 DOI: 10.1177/2048872620924198] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 04/16/2020] [Indexed: 11/17/2022]
Abstract
BACKGROUND Most studies assessing the diagnostic value of high-sensitivity troponin in the diagnosis of myocardial infarction used batch-wise analyses of frozen samples for high-sensitivity troponin measurements. Whether the accuracy of these batch-wise high-sensitivity troponin measurements described in diagnostic studies is comparable to clinical routine is unknown. METHODS We enrolled 937 patients presenting with suspected myocardial infarction in this prospective cohort study. Measurements of high-sensitivity troponin I (Abbott Architect) and high-sensitivity troponin T (Roche) were performed in two settings: (a) on-demand in clinical routine using fresh blood samples; and (b) in batches using frozen blood samples from the same individuals at three timepoints (0 hours, 1 hour and 3 hours after presentation). RESULTS Median troponin levels were not different between on-demand and batch-wise measurements. Troponin levels in the range of 0 to 40 ng/L showed a very high correlation between the on-demand and batch setting (Pearson correlation coefficient (r) was 0.92-0.95 for high-sensitivity troponin I and 0.96 for high-sensitivity troponin T). However, at very low troponin levels (0 to 10 ng/L) correlation between the two settings was moderate (r for high-sensitivity troponin I 0.59-0.66 and 0.65-0.69 for high-sensitivity troponin T). Application of guideline-recommended rapid diagnostic algorithms showed similar diagnostic performance with both methods. CONCLUSIONS Overall on-demand and batch-wise measurements of high-sensitivity troponin provided similar results, but their correlation was moderate, when focusing on very low troponin levels. The application of rapid diagnostic algorithms was safe in both settings.Trial Registration: www.clinicaltrials.gov (NCT02355457).
Collapse
|
18
|
Predictive Value of Serial ECGs in Patients with Suspected Myocardial Infarction. J Clin Med 2020; 9:jcm9072303. [PMID: 32698466 PMCID: PMC7408822 DOI: 10.3390/jcm9072303] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 07/13/2020] [Accepted: 07/15/2020] [Indexed: 12/15/2022] Open
Abstract
The electrocardiogram (ECG) is an important diagnostic tool for patients with suspected acute myocardial infarction (AMI). Current guidelines recommend serial ECGs in case of persisting symptoms. We aimed to analyze the predictive value of ischemic ECG-signs in patients with suspected AMI. Patients presenting to the emergency department with suspected AMI were included. All patients with ST-elevation AMI were excluded from analyses. Patients received 12-lead-ECG and high-sensitive Troponin T (hs-TnT)-measurement at admission and after 3 h. Four groups were defined: no ischemic signs in either ECG; new ischemic signs in the second ECG; resolved ischemic signs in the second ECG; and persistent ischemic signs in both ECGs. Patients were followed for 2 years to assess the composite endpoint of all-cause-mortality, AMI, and coronary revascularization. Using a 30-day landmark analysis, a Cox regression with ischemic signs as the variable of interest, adjusted by cardiovascular risk factors, was calculated. Of 1675 patients, 1321 showed no ischemic signs, in 25 new-, in 92 resolved- and in 237 patients, persistent ischemic signs were documented. Patients with persistent ischemic signs had significantly worse outcomes, compared to those without. Compared to no ischemic signs, adjusted hazard ratios for the combined endpoint were 0.81 (95% CI 0.20, 3.31; p-value = 0.77) for new-, 0.59 (95% CI 0.26, 1.34; p-value = 0.21) for resolved-, and 1.47 (95% CI 1.102, 2.13; p-value = 0.041) for persistent ischemic signs. In patients with suspected AMI, persistent ischemic ECG-signs are predictive of a higher rate of all-cause-mortality, AMI, and revascularization.
Collapse
|
19
|
Admission troponin measurement for the diagnosis of myocardial infarction: the search for one and done continues. EUROPEAN HEART JOURNAL. QUALITY OF CARE & CLINICAL OUTCOMES 2020; 6:184-185. [PMID: 32163132 DOI: 10.1093/ehjqcco/qcaa021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
20
|
Application of a machine learning-driven, multibiomarker panel for prediction of incident cardiovascular events in patients with suspected myocardial infarction. Biomark Med 2020; 14:775-784. [PMID: 32462911 DOI: 10.2217/bmm-2019-0584] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Background: In patients with suspected myocardial infarction (MI), we sought to validate a machine learning-driven, multibiomarker panel for prediction of incident major adverse cardiovascular events (MACE). Methodology & results: A previously described prognostic panel for MACE consisting of four biomarkers was measured in 748 patients with suspected MI. The investigated end point was incident MACE within 1 year. The prognostic value of a continuous score and an optimal cut-off was investigated. The area under the curve was 0.86 for the overall model. Using the optimal cut-off resulted in a negative predictive value of 99.4% for incident MACE. Patients with an elevated prognostic score were at high risk for MACE. Conclusion: Among patients with suspected MI, we validated a multibiomarker panel for predicting 1-year MACE. Clinical Trial Registration: NCT02355457 (ClinicalTrials.gov).
Collapse
|
21
|
Undetectable high-sensitivity troponin in combination with clinical assessment for risk stratification of patients with chest pain and normal troponin at hospital arrival. EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE 2020; 9:567-575. [PMID: 32067483 DOI: 10.1177/2048872620907539] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
BACKGROUND Undetectable high-sensitivity cardiac troponin (hs-cTn) in a single determination upon admission may rule out acute coronary syndrome. We investigated undetectable hs-cTnT (<detection limit; <5 ng/l) together with clinical risk scores (GRACE, TIMI, HEART and a previously published simple score), for one-year outcomes in patients with chest pain and normal hs-cTnT (<99th percentile; <14 ng/l) upon admission. METHODS This study was a retrospective design involving 2254 consecutive patients (July 2016-November 2017). The primary endpoint was one-year death or acute myocardial infarction; the secondary endpoint added unstable angina requiring revascularization. Early (<90 minutes since pain onset, n = 661) and late (n = 1593) presenters were separately considered. RESULTS A total of 56 (2.5%) patients reached the primary endpoint and 91 (4%) the secondary endpoint. Undetectable hs-cTnT had a poor C-statistic in early and late presenters (0.648 and 0.703, respectively). Adding hs-cTnT measurable concentrations above the detection limit (as continuous variable) significantly enhanced the C-statistics (0.754 and 0.847, respectively). Addition of the HEART (0.809, p = 0.005) or simple clinical scores (0.804, p = 0.02) further improved the model and significantly reclassified patient risk, in early presenters. The results were similar for the secondary endpoint. The TIMI risk score performed worse and the GRACE score did not give additional information. In late presenters, no clinical score provided significant additional information over hs-cTnT. CONCLUSIONS Diagnostic algorithms should consider not only whether hs-cTnT is above or below the detection limit but also its concentration if above, for risk stratification over one year in patients with initial normal hs-cTnT. The clinical scores provide valuable additional information in early presenters.
Collapse
|
22
|
Performance of the ESC 0/1-h and 0/3-h Algorithm for the Rapid Identification of Myocardial Infarction Without ST-Elevation in Patients With Diabetes. Diabetes Care 2020; 43:460-467. [PMID: 31843947 PMCID: PMC9162128 DOI: 10.2337/dc19-1327] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 11/09/2019] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Patients with diabetes mellitus (DM) have elevated levels of high-sensitivity cardiac troponin (hs-cTn). We investigated the diagnostic performance of the European Society of Cardiology (ESC) algorithms to rule out or rule in acute myocardial infarction (AMI) without ST-elevation in patients with DM. RESEARCH DESIGN AND METHODS We prospectively enrolled 3,681 patients with suspected AMI and stratified those by the presence of DM. The ESC 0/1-h and 0/3-h algorithms were used to calculate negative and positive predictive values (NPV, PPV). In addition, alternative cutoffs were calculated and externally validated in 2,895 patients. RESULTS In total, 563 patients (15.3%) had DM, and 137 (24.3%) of these had AMI. When the ESC 0/1-h algorithm was used, the NPV was comparable in patients with and without DM (absolute difference [AD] -1.50 [95% CI -5.95, 2.96]). In contrast, the ESC 0/3-h algorithm resulted in a significantly lower NPV in patients with DM (AD -2.27 [95% CI -4.47, -0.07]). The diagnostic performance for rule-in of AMI (PPV) was comparable in both groups: 0/1-h (AD 6.59 [95% CI -19.53, 6.35]) and 0/3-h (AD 1.03 [95% CI -7.63, 9.7]). Alternative cutoffs increased the PPV in both algorithms significantly, while improvements in NPV were only subtle. CONCLUSIONS Application of the ESC 0/1-h algorithm revealed comparable safety to rule out AMI comparing patients with and without DM, while this was not observed with the ESC 0/3-h algorithm. Although alternative cutoffs might be helpful, patients with DM remain a high-risk population in whom identification of AMI is challenging and who require careful clinical evaluation.
Collapse
|
23
|
[Clinical and Diagnostic Value of Cardiac Markers in Human Biological Fluids]. ACTA ACUST UNITED AC 2019; 59:66-75. [PMID: 31849301 DOI: 10.18087/cardio.2019.11.n414] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Accepted: 03/22/2019] [Indexed: 11/18/2022]
Abstract
The article is devoted to problems of clinical-diagnostic value of determination of cardio-specific troponins in human biological fluids. Improvement of laboratory instrumentation and emergence of high sensitivity methods of analysis have allowed to identify troponins in urine, dialysate, and oral fluid. In the review we present actual information related to measurement of troponins in blood serum, data on testing of cardio-specific troponins in urine, dialysate, and oral fluid. Special attention is paid to determination of some cardiomarkers in oral fluid with thorough analysis of diagnostic value and effectiveness of the conducted studies.
Collapse
|
24
|
Diagnostic Evaluation of a High-Sensitivity Troponin I Point-of-Care Assay. Clin Chem 2019; 65:1592-1601. [DOI: 10.1373/clinchem.2019.307405] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Accepted: 08/30/2019] [Indexed: 11/06/2022]
Abstract
Abstract
BACKGROUND
Increasing numbers of patients are presenting worldwide to emergency departments with suspected myocardial infarction. The use of point-of-care troponin assays might enable faster decision-making in this high-risk population and reduce the burden on emergency facilities. Here, we evaluate the diagnostic performance of a point-of-care high-sensitivity troponin I assay.
METHODS
We conducted a prospective cohort study including patients presenting to the emergency department with suspected myocardial infarction from July 2013 to July 2016. A diagnostic algorithm for a high-sensitivity troponin I point-of-care assay was developed in a derivation data set with 669 patients and validated in an additional 610 patients.
RESULTS
The derived 0/1 h algorithm for the point-of-care assay consisted of an admission troponin I <4 ng/L and a δ from 0 h to 1 h <3 ng/L for rule out and an admission troponin I ≥90 ng/L or a δ from 0 h to 1 h ≥20 ng/L for rule in of non-ST-elevation myocardial infarction. Application to the validation cohort showed a negative predictive value of 99.7% (95% CI, 98.1%–100.0%) and 48.0% of patients ruled out, whereas 14.6% were ruled in with a positive predictive value of 86.5% (95% CI, 77.6%–92.8%). The diagnostic performance of the point-of-care high-sensitivity assay was highly comparable to guideline-recommended use of a laboratory-based high-sensitivity troponin assay.
CONCLUSIONS
The clinical application of a 0/1 h diagnostic algorithm based on a high-sensitivity troponin I point-of-care assay is safe, and diagnostic performance is comparable to a laboratory-based high-sensitivity troponin I assay.
Collapse
|
25
|
Clinical chemistry score versus high-sensitivity cardiac troponin I and T tests alone to identify patients at low or high risk for myocardial infarction or death at presentation to the emergency department. CMAJ 2019; 190:E974-E984. [PMID: 30127037 DOI: 10.1503/cmaj.180144] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/09/2018] [Indexed: 01/10/2023] Open
Abstract
BACKGROUND Testing for high-sensitivity cardiac troponin (hs-cTn) may assist triage and clinical decision-making in patients presenting to the emergency department with symptoms of acute coronary syndrome; however, this could result in the misclassification of risk because of analytical variation or laboratory error. We sought to evaluate a new laboratory-based risk-stratification tool that incorporates tests for hs-cTn, glucose level and estimated glomerular filtration rate to identify patients at risk of myocardial infarction or death when presenting to the emergency department. METHODS We constructed the clinical chemistry score (CCS) (range 0-5 points) and validated it as a predictor of 30-day myocardial infarction (MI) or death using data from 4 cohort studies involving patients who presented to the emergency department with symptoms suggestive of acute coronary syndrome. We calculated diagnostic parameters for the CCS score separately using high-sensitivity cardiac troponin I (hs-cTnI) and high-sensitivity cardiac troponin T (hs-cTnT). RESULTS For the combined cohorts (n = 4245), 17.1% of participants had an MI or died within 30 days. A CCS score of 0 points best identified low-risk participants: the hs-cTnI CCS had a sensitivity of 100% (95% confidence interval [CI] 99.5%-100%), with 8.9% (95% CI 8.1%-9.8%) of the population classified as being at low risk of MI or death within 30 days; the hs-cTnT CCS had a sensitivity of 99.9% (95% CI 99.2%-100%), with 10.5% (95% CI 9.6%-11.4%) of the population classified as being at low risk. The CCS had better sensitivity than hs-cTn alone (hs-cTnI < 5 ng/L: 96.6%, 95% CI 95.0%-97.8%; hs-cTnT < 6 ng/L: 98.2%, 95% CI 97.0%-99.0%). A CCS score of 5 points best identified patients at high risk (hs-cTnI CCS: specificity 96.6%, 95% CI 96.0%-97.2%; 11.2% [95% CI 10.3%-12.2%] of the population classified as being at high risk; hs-cTnT CCS: specificity 94.0%, 95% CI 93.1%-94.7%; 13.1% [95% CI 12.1%-14.1%] of the population classified as being at high risk) compared with using the overall 99th percentiles for the hs-cTn assays (specificity of hs-cTnI 93.2%, 95% CI 92.3-94.0; specificity of hs-cTnT 73.8%, 95% CI 72.3-75.2). INTERPRETATION The CCS score at the chosen cut-offs was more sensitive and specific than hs-cTn alone for risk stratification of patients presenting to the emergency department with suspected acute coronary syndrome. Study registration: ClinicalTrials.gov, nos. NCT01994577; NCT02355457.
Collapse
|
26
|
High-Sensitivity Troponin and the Application of Risk Stratification Thresholds in Patients With Suspected Acute Coronary Syndrome. Circulation 2019; 140:1557-1568. [PMID: 31475856 PMCID: PMC6831036 DOI: 10.1161/circulationaha.119.042866] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Supplemental Digital Content is available in the text. Guidelines acknowledge the emerging role of high-sensitivity cardiac troponin (hs-cTnl) for risk stratification and the early rule-out of myocardial infarction, but multiple thresholds have been described. We evaluate the safety and effectiveness of risk stratification thresholds in patients with suspected acute coronary syndrome.
Collapse
|
27
|
Multicentre cross-sectional observational registry to monitor the safety of early discharge after rule-out of acute myocardial infarction by copeptin and troponin: the Pro-Core registry. BMJ Open 2019; 9:e028311. [PMID: 31340965 PMCID: PMC6661885 DOI: 10.1136/bmjopen-2018-028311] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
OBJECTIVES There is sparse information on the safety of early primary discharge from the emergency department (ED) after rule-out of myocardial infarction in suspected acute coronary syndrome (ACS). This prospective registry aimed to confirm randomised study results in patients at low-to-intermediate risk, with a broader spectrum of symptoms, across different institutional standards and with a range of local troponin assays including high-sensitivity cTn (hs-cTn), cardiac troponin (cTn) and point-of-care troponin (POC Tn). DESIGN Prospective, multicentre European registry. SETTING 18 emergency departments in nine European countries (Germany, Austria, Switzerland, France, Spain, UK, Turkey, Lithuania and Hungary) PARTICIPANTS: The final study cohort consisted of 2294 patients (57.2% males, median age 57 years) with suspected ACS. INTERVENTIONS Using the new dual markers strategy, 1477 patients were eligible for direct discharge, which was realised in 974 (42.5%) of patients. MAIN OUTCOME MEASURES The primary endpoint was all-cause mortality at 30 days. RESULTS Compared with conventional workup after dual marker measurement, the median length of ED stay was 60 min shorter (228 min, 95% CI: 219 to 239 min vs 288 min, 95% CI: 279 to 300 min) in the primary dual marker strategy (DMS) discharge group. All-cause mortality was 0.1% (95% CI: 0% to 0.6%) in the primary DMS discharge group versus 1.1% (95% CI: 0.6% to 1.8%) in the conventional workup group after dual marker measurement. Conventional workup instead of discharge despite negative DMS biomarkers was observed in 503 patients (21.9%) and associated with higher prevalence of ACS (17.1% vs 0.9%, p<0.001), cardiac diagnoses (55.2% vs 23.5%, p<0.001) and risk factors (p<0.01), but with a similar all-cause mortality of 0.2% (95% CI: 0% to 1.1%) versus primary DMS discharge (p=0.64). CONCLUSIONS Copeptin on top of cardiac troponin supports safe discharge in patients with chest pain or other symptoms suggestive of ACS under routine conditions with the use of a broad spectrum of local standard POC, conventional and high-sensitivity troponin assays. TRIAL REGISTRATION NUMBER NCT02490969.
Collapse
|
28
|
Thymoma mimicking an aortic aneurysm: always expect the unexpected. BMJ Case Rep 2019; 12:12/7/e230073. [PMID: 31320375 DOI: 10.1136/bcr-2019-230073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Thymic epithelial tumours (TETs) are rare lesions that represent less than 1% of all malignancies in adults. Presentation occurs in three ways: asymptomatic, with local thoracic symptoms or with paraneoplastic symptoms. Heterotopic ossifications are rare histological features in neoplasms and non-neoplastic lesions. Here, we present a 49-year-old male patient with a thymoma type B2 mimicking an aortic aneurysm. Alongside the thymoma, a cholesterol granuloma with unusual ossification features was found as well. This clinical presentation and pathological diagnosis are unusual findings.
Collapse
|
29
|
Evaluation of a new ultra-sensitivity troponin I assay in patients with suspected myocardial infarction. Int J Cardiol 2019; 283:35-40. [DOI: 10.1016/j.ijcard.2018.12.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Revised: 11/05/2018] [Accepted: 12/03/2018] [Indexed: 12/25/2022]
|
30
|
High-sensitivity cardiac troponins: sex-specific values in clinical practice. Precision or confusion? Hellenic J Cardiol 2019; 60:171-177. [DOI: 10.1016/j.hjc.2019.02.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Revised: 02/04/2019] [Accepted: 02/27/2019] [Indexed: 02/06/2023] Open
|
31
|
Diagnostic Value of Soluble Urokinase-Type Plasminogen Activator Receptor in Addition to High-Sensitivity Troponin I in Early Diagnosis of Acute Myocardial Infarction. Biomolecules 2019; 9:biom9030108. [PMID: 30889909 PMCID: PMC6468350 DOI: 10.3390/biom9030108] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Revised: 03/08/2019] [Accepted: 03/14/2019] [Indexed: 02/07/2023] Open
Abstract
The soluble urokinase-type plasminogen activator receptor (suPAR) is a new marker for immune activation and inflammation and may provide diagnostic value on top of established biomarkers in patients with suspected acute myocardial infarction (AMI). Here, we evaluate the diagnostic potential of suPAR levels on top of high-sensitivity troponin I (hs-TnI) in a cohort of patients with suspected AMI. A total of 1220 patients presenting to the emergency department with suspected AMI were included, of whom 245 were diagnosed with AMI. Median suPAR levels at admission were elevated in subjects with AMI compared to non-AMI (3.8 ng/mL vs. 3.3 ng/mL, p = 0.001). In C-statistics, the area under the curve (AUC) regarding the diagnosis of AMI was low (0.57 at an optimized cut-off of 3.7 ng/mL). Moreover, baseline suPAR levels on top of troponin values at admission and hour 1 reduced the number of patients who were correctly ruled-out as non-AMI, and who were correctly ruled-in as AMI. Our study shows that circulating levels of suPAR on top of high-sensitivity troponin I do not improve the early diagnosis of AMI.
Collapse
|
32
|
High-sensitivity troponin in the evaluation of patients with suspected acute coronary syndrome: a stepped-wedge, cluster-randomised controlled trial. Lancet 2018; 392:919-928. [PMID: 30170853 PMCID: PMC6137538 DOI: 10.1016/s0140-6736(18)31923-8] [Citation(s) in RCA: 228] [Impact Index Per Article: 38.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Revised: 08/08/2018] [Accepted: 08/10/2018] [Indexed: 12/11/2022]
Abstract
BACKGROUND High-sensitivity cardiac troponin assays permit use of lower thresholds for the diagnosis of myocardial infarction, but whether this improves clinical outcomes is unknown. We aimed to determine whether the introduction of a high-sensitivity cardiac troponin I (hs-cTnI) assay with a sex-specific 99th centile diagnostic threshold would reduce subsequent myocardial infarction or cardiovascular death in patients with suspected acute coronary syndrome. METHODS In this stepped-wedge, cluster-randomised controlled trial across ten secondary or tertiary care hospitals in Scotland, we evaluated the implementation of an hs-cTnI assay in consecutive patients who had been admitted to the hospitals' emergency departments with suspected acute coronary syndrome. Patients were eligible for inclusion if they presented with suspected acute coronary syndrome and had paired cardiac troponin measurements from the standard care and trial assays. During a validation phase of 6-12 months, results from the hs-cTnI assay were concealed from the attending clinician, and a contemporary cardiac troponin I (cTnI) assay was used to guide care. Hospitals were randomly allocated to early (n=5 hospitals) or late (n=5 hospitals) implementation, in which the high-sensitivity assay and sex-specific 99th centile diagnostic threshold was introduced immediately after the 6-month validation phase or was deferred for a further 6 months. Patients reclassified by the high-sensitivity assay were defined as those with an increased hs-cTnI concentration in whom cTnI concentrations were below the diagnostic threshold on the contemporary assay. The primary outcome was subsequent myocardial infarction or death from cardiovascular causes at 1 year after initial presentation. Outcomes were compared in patients reclassified by the high-sensitivity assay before and after its implementation by use of an adjusted generalised linear mixed model. This trial is registered with ClinicalTrials.gov, number NCT01852123. FINDINGS Between June 10, 2013, and March 3, 2016, we enrolled 48 282 consecutive patients (61 [SD 17] years, 47% women) of whom 10 360 (21%) patients had cTnI concentrations greater than those of the 99th centile of the normal range of values, who were identified by the contemporary assay or the high-sensitivity assay. The high-sensitivity assay reclassified 1771 (17%) of 10 360 patients with myocardial injury or infarction who were not identified by the contemporary assay. In those reclassified, subsequent myocardial infarction or cardiovascular death within 1 year occurred in 105 (15%) of 720 patients in the validation phase and 131 (12%) of 1051 patients in the implementation phase (adjusted odds ratio for implementation vs validation phase 1·10, 95% CI 0·75 to 1·61; p=0·620). INTERPRETATION Use of a high-sensitivity assay prompted reclassification of 1771 (17%) of 10 360 patients with myocardial injury or infarction, but was not associated with a lower subsequent incidence of myocardial infarction or cardiovascular death at 1 year. Our findings question whether the diagnostic threshold for myocardial infarction should be based on the 99th centile derived from a normal reference population. FUNDING The British Heart Foundation.
Collapse
|
33
|
High sensitivity troponin: The Sisyphean pursuit of zero percent miss rate for acute coronary syndrome in the ED. Am J Emerg Med 2018; 36:1088-1097. [DOI: 10.1016/j.ajem.2018.03.075] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 03/22/2018] [Accepted: 03/28/2018] [Indexed: 10/17/2022] Open
|
34
|
Profile of Roche’s Elecsys Troponin T Gen 5 STAT blood test (a high-sensitivity cardiac troponin assay) for diagnosing myocardial infarction in the emergency department. Expert Rev Mol Diagn 2018; 18:481-489. [DOI: 10.1080/14737159.2018.1476141] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
35
|
|
36
|
Evaluating Rapid Rule-out of Acute Myocardial Infarction Using a High-Sensitivity Cardiac Troponin I Assay at Presentation. Clin Chem 2018; 64:820-829. [DOI: 10.1373/clinchem.2017.283887] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Accepted: 01/16/2018] [Indexed: 12/12/2022]
Abstract
Abstract
BACKGROUND
Low concentrations of cardiac troponin (cTn) have been recommended for rapid rule-out of acute myocardial infarction (AMI). We examined the Beckman Coulter Access high-sensitivity cardiac troponin I (hs-cTnI) assay to identify a single test threshold that can safely rule out AMI.
METHODS
This analysis used stored samples collected in 2 prospective observational studies. In all, 1871 patients presenting to a tertiary emergency department with symptoms of acute coronary syndrome had blood taken for measurement of cTnI on presentation. The endpoint was type 1 myocardial infarction (T1MI). Sensitivity and negative predictive value (NPV) were calculated for hs-cTnI values below the 99th percentile.
RESULTS
Ninety-eight patients had T1MI (5.2%), and 638 (34.1%) patients had an hs-cTnI <2 ng/L (limit of detection), with sensitivity of 99.0% (95% CI, 94.4%–100%) and NPV of 99.8% (95% CI, 99.1%–100%). No hs-cTnI value above a concentration of 2 ng/L achieved sensitivity of 99%. However, an NPV of 99.5% was achieved at values <6 ng/L. A cutoff <6 ng/L enabled 1475 (78.8%) patients to be ruled out on presentation with sensitivity of 93.9% (95% CI, 87.1%–97.7%).
CONCLUSIONS
A single baseline cTn <2 ng/L measured with the Access hs-cTnI assay performed well for rule-out of AMI. This cutoff concentration identified 99% of patients with AMI and could reduce the number of patients requiring lengthy assessment. A cutoff of <6 ng/L yielded a high NPV but missed more cases of AMI than would be acceptable to clinicians.
Collapse
|
37
|
High-Sensitivity Cardiac Troponin and the Risk Stratification of Patients With Renal Impairment Presenting With Suspected Acute Coronary Syndrome. Circulation 2018; 137:425-435. [PMID: 28978551 PMCID: PMC5793996 DOI: 10.1161/circulationaha.117.030320] [Citation(s) in RCA: 66] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Accepted: 09/18/2017] [Indexed: 12/14/2022]
Abstract
BACKGROUND High-sensitivity cardiac troponin testing may improve the risk stratification and diagnosis of myocardial infarction, but concentrations can be challenging to interpret in patients with renal impairment, and the effectiveness of testing in this group is uncertain. METHODS In a prospective multicenter study of consecutive patients with suspected acute coronary syndrome, we evaluated the performance of high-sensitivity cardiac troponin I in those with and without renal impairment (estimated glomerular filtration rate <60mL/min/1.73m2). The negative predictive value and sensitivity of troponin concentrations below the risk stratification threshold (5 ng/L) at presentation were reported for a primary outcome of index type 1 myocardial infarction, or type 1 myocardial infarction or cardiac death at 30 days. The positive predictive value and specificity at the 99th centile diagnostic threshold (16 ng/L in women, 34 ng/L in men) was determined for index type 1 myocardial infarction. Subsequent type 1 myocardial infarction and cardiac death were reported at 1 year. RESULTS Of 4726 patients identified, 904 (19%) had renal impairment. Troponin concentrations <5 ng/L at presentation identified 17% of patients with renal impairment as low risk for the primary outcome (negative predictive value, 98.4%; 95% confidence interval [CI], 96.0%-99.7%; sensitivity 98.9%; 95%CI, 97.5%-99.9%), in comparison with 56% without renal impairment (P<0.001) with similar performance (negative predictive value, 99.7%; 95% CI, 99.4%-99.9%; sensitivity 98.4%; 95% CI, 97.2%-99.4%). The positive predictive value and specificity at the 99th centile were lower in patients with renal impairment at 50.0% (95% CI, 45.2%-54.8%) and 70.9% (95% CI, 67.5%-74.2%), respectively, in comparison with 62.4% (95% CI, 58.8%-65.9%) and 92.1% (95% CI, 91.2%-93.0%) in those without. At 1 year, patients with troponin concentrations >99th centile and renal impairment were at greater risk of subsequent myocardial infarction or cardiac death than those with normal renal function (24% versus 10%; adjusted hazard ratio, 2.19; 95% CI, 1.54-3.11). CONCLUSIONS In suspected acute coronary syndrome, high-sensitivity cardiac troponin identified fewer patients with renal impairment as low risk and more as high risk, but with lower specificity for type 1 myocardial infarction. Irrespective of diagnosis, patients with renal impairment and elevated cardiac troponin concentrations had a 2-fold greater risk of a major cardiac event than those with normal renal function, and should be considered for further investigation and treatment. CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifier: NCT01852123.
Collapse
|
38
|
Modification of the Thrombolysis in Myocardial Infarction risk score for patients presenting with chest pain to the emergency department. Emerg Med Australas 2017; 30:47-54. [PMID: 29232768 DOI: 10.1111/1742-6723.12913] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2017] [Accepted: 10/31/2017] [Indexed: 12/22/2022]
Abstract
OBJECTIVE To develop a modified Thrombolysis in Myocardial Infarction (TIMI) score to effectively risk stratify patients presenting to the ED with chest pain. METHODS A prospective observational study was conducted at two metropolitan EDs. Data were obtained during patient interview. The primary outcome was major adverse cardiovascular events (MACE) within 30 days of presentation. Two separate modifications of the TIMI score were developed. These scores were compared to the original TIMI in terms of the area under the receiver operating characteristic curve and diagnostic accuracy statistics (sensitivity, specificity, positive and negative predictive values). RESULTS Of 1760 patients, 364 (20.7%) experienced 30 day MACE. The first modified TIMI score was a simplified TIMI (s-TIMI) including four variables: age ≥65 years, three or more risk factors, high-sensitivity troponin (hs-cTnI) and electrocardiogram changes. The second score included the same four variables plus two Global Registry of Acute Coronary Events (GRACE) variables (systolic blood pressure and estimated glomerular filtration rate). This score was termed the GRACE TIMI (g-TIMI). s-TIMI had a lower sensitivity compared to the original TIMI score (93.41 and 96.98%), but higher specificity (45.49 and 24.50%). The g-TIMI had a sensitivity of 98.90% and specificity of 14.90%. CONCLUSIONS Attempts to modify the TIMI score yielded two scores with added predictive utility in comparison to the original TIMI model. The addition of GRACE variables (g-TIMI) increased sensitivity for MACE, but decreased the specificity of the model. The s-TIMI score yielded good specificity but had sensitivity that would not be acceptable by emergency physicians. The s-TIMI may be useful as part of an accelerated chest pain protocol.
Collapse
|
39
|
Association of High-Sensitivity Cardiac Troponin I Concentration With Cardiac Outcomes in Patients With Suspected Acute Coronary Syndrome. JAMA 2017; 318:1913-1924. [PMID: 29127948 PMCID: PMC5710293 DOI: 10.1001/jama.2017.17488] [Citation(s) in RCA: 167] [Impact Index Per Article: 23.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2017] [Accepted: 10/22/2017] [Indexed: 12/17/2022]
Abstract
Importance High-sensitivity cardiac troponin I testing is widely used to evaluate patients with suspected acute coronary syndrome. A cardiac troponin concentration of less than 5 ng/L identifies patients at presentation as low risk, but the optimal threshold is uncertain. Objective To evaluate the performance of a cardiac troponin I threshold of 5 ng/L at presentation as a risk stratification tool in patients with suspected acute coronary syndrome. Data Sources Systematic search of MEDLINE, EMBASE, Cochrane, and Web of Science databases from January 1, 2006, to March 18, 2017. Study Selection Prospective studies measuring high-sensitivity cardiac troponin I concentrations in patients with suspected acute coronary syndrome in which the diagnosis was adjudicated according to the universal definition of myocardial infarction. Data Extraction and Synthesis The systematic review identified 19 cohorts. Individual patient-level data were obtained from the corresponding authors of 17 cohorts, with aggregate data from 2 cohorts. Meta-estimates for primary and secondary outcomes were derived using a binomial-normal random-effects model. Main Outcomes and Measures The primary outcome was myocardial infarction or cardiac death at 30 days. Performance was evaluated in subgroups and across a range of troponin concentrations (2-16 ng/L) using individual patient data. Results Of 11 845 articles identified, 104 underwent full-text review, and 19 cohorts from 9 countries were included. Among 22 457 patients included in the meta-analysis (mean age, 62 [SD, 15.5] years; n = 9329 women [41.5%]), the primary outcome occurred in 2786 (12.4%). Cardiac troponin I concentrations were less than 5 ng/L at presentation in 11 012 patients (49%), in whom there were 60 missed index or 30-day events (59 index myocardial infarctions, 1 myocardial infarction at 30 days, and no cardiac deaths at 30 days). This resulted in a negative predictive value of 99.5% (95% CI, 99.3%-99.6%) for the primary outcome. There were no cardiac deaths at 30 days and 7 (0.1%) at 1 year, with a negative predictive value of 99.9% (95% CI, 99.7%-99.9%) for cardiac death. Conclusions and Relevance Among patients with suspected acute coronary syndrome, a high-sensitivity cardiac troponin I concentration of less than 5 ng/L identified those at low risk of myocardial infarction or cardiac death within 30 days. Further research is needed to understand the clinical utility and cost-effectiveness of this approach to risk stratification.
Collapse
|
40
|
Discrimination of patients with type 2 myocardial infarction. Eur Heart J 2017; 38:3514-3520. [DOI: 10.1093/eurheartj/ehx457] [Citation(s) in RCA: 74] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Accepted: 07/19/2017] [Indexed: 01/02/2023] Open
|
41
|
A Rational Adoption of the High Sensitive Assay for Cardiac Troponin I in Diagnostic Routine. DISEASE MARKERS 2017; 2017:4523096. [PMID: 28588346 PMCID: PMC5447265 DOI: 10.1155/2017/4523096] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Revised: 03/09/2017] [Accepted: 03/21/2017] [Indexed: 11/17/2022]
Abstract
We describe the adoption of high sensitive troponin I (hsTnI) in clinical practice in two hospital settings in Italy. Samples from 426 consecutive patients (mean age 68.8 ± 17.0) admitted to the Emergency Department with a suspected acute coronary syndrome (ACS) have been tested at admittance and after 3 and 6 hours by contemporary TnI and hsTnI. Results have been compared to the final clinical diagnosis. Troponin was detectable in 68.6% by TnI and 89.9% by hsTnI. Since hsTnI has a lower threshold for females, 38/41 patients with positive values only by hsTnI were women. The correlation between the assays was very high (r = 0.92). A diagnosis of acute myocardial infarction (AMI) was made in 45 cases (10.5%). The negative and positive predictive values for a 50% troponin variation at 3 hours were 95.8% and 66.7% for hsTnI and 95.0% and 52.6% for TnI and at 6 hours 90.3% and 100% for hsTnI and 88.9% and 78.9% for TnI, respectively. Receiver operating characteristic (ROC) curve analysis demonstrated a greater efficiency by hsTnI at 3 hours versus 6 hours (AUC = 0.91 versus 0.72). The main benefits of hsTnI are the adoption of gender-specific 99th percentile and the shortening of time to decision.
Collapse
|
42
|
|
43
|
Early diagnosis of acute myocardial infarction using high-sensitivity troponin I. PLoS One 2017; 12:e0174288. [PMID: 28333976 PMCID: PMC5363912 DOI: 10.1371/journal.pone.0174288] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Accepted: 03/06/2017] [Indexed: 01/11/2023] Open
Abstract
Objective There is a clinical need for early and accurate diagnosis of acute myocardial infarction (AMI). Current European Society of Cardiology (ESC) guidelines recommend diagnosis of non-ST-elevation AMI based on serial troponin measurements. We aimed to challenge the ESC guidelines using 1) a high-sensitivity troponin I (hs-TnI) baseline cutoff, 2) an absolute hs-TnI change after 1 hour and 3) additional application of an ischemic ECG. Methods 1,516 patients with suspected AMI presenting to the emergency department were included. Hs-TnI was measured directly at admission, after 1 and 3 hours. We investigated baseline concentrations, absolute changes of hs-TnI and additional application of an ischemic ECG to diagnose AMI. A positive predictive value (PPV) of more than 85% was targeted. Results The median age of the study population was 65 years; 291 patients were diagnosed with AMI. The PPV of the 3-hours ESC algorithm was 85.5% (CI 79.7, 90.1) and 65.8% (CI 60.5,70.8) for the 1-hour algorithm. Using a high baseline hs-TnI concentration of 150 ng/L resulted in a PPV of 87.8% (CI 80.9,92.9). Alternatively, a hs-TnI change of 20 ng/L after 1 hour, resulted in a PPV of 86.5% (80.9,91.0), respectively for the diagnosis of AMI. Additional use of an ischemic ECG increased the PPV to 90.5% (CI 83.2,95.3), while reducing the efficacy. Conclusion The diagnosis of AMI based on hs-TnI is challenging. The application of absolute hs-TnI changes after 1 hour may facilitate rapid rule-in of patients. Trial registration www.clinicaltrials.gov (NCT02355457).
Collapse
|
44
|
A laboratory score at presentation to rule-out serious cardiac outcomes or death in patients presenting with symptoms suggestive of acute coronary syndrome. Clin Chim Acta 2017; 469:69-74. [PMID: 28342713 DOI: 10.1016/j.cca.2017.03.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Revised: 03/20/2017] [Accepted: 03/22/2017] [Indexed: 11/21/2022]
Abstract
BACKGROUND We evaluated whether a low high-sensitivity cardiac troponin (hs-cTn) cutoff combined with glucose, red cell distribution width (RDW), and the estimated glomerular filtration rate (eGFR) can be used to rule-out a serious cardiac outcome or death in patients presenting with symptoms suggestive of acute coronary syndrome (ACS). METHODS This was a prospective observational emergency department (ED) study enrolling consecutive patients presenting with symptoms suggestive of ACS (ClinicalTrials.gov: NCT01994577). The primary outcome was a 7-day composite of myocardial infarction, unstable angina, decompensated congestive heart failure, serious ventricular cardiac arrhythmia, or death. A laboratory score combining glucose, RDW, eGFR with hs-cTnT (Roche) or hs-cTnI (Abbott) was compared to hs-cTn alone using the limit of detection (LoD; hs-cTnT<5ng/l/hs-cTnI<2ng/l) as the cutoff. A benchmark of >99% sensitivity was used to assess the laboratory panel with hs-cTn versus the LoD alone to identify low-risk patients suitable for discharge. RESULTS A total of 1095 patients (n=267 composite-outcomes) had measurements of glucose, RDW, eGFR, hs-cTnT, and hs-cTnI at presentation. Applying the hs-cTn LoD alone as the cutoff missed 5 composite-outcomes (sensitivity=98.1%), however the addition of the laboratory panel to the hs-cTn LoD increased the sensitivity to >99% with approximately 10% of the population identified as low-risk. The percentage of low-risk patients was increased to 15% (1 composite-outcome missed) when employing a low measurable hs-cTnI cutoff with the laboratory panel (laboratory score<2 points). CONCLUSION A laboratory score with hs-cTn may identify low-risk patients suitable for ED discharge at presentation.
Collapse
|
45
|
Stressing the Utility of High-Sensitivity Cardiac Troponin Testing in Patients with Possible Cardiac Ischemia. J Appl Lab Med 2017; 1:468-470. [PMID: 33379791 DOI: 10.1373/jalm.2016.022491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Accepted: 12/16/2016] [Indexed: 11/06/2022]
|
46
|
Fast track protocols using highly sensitive troponin assays for ruling out and ruling in non-ST elevation acute coronary syndrome. ACTA ACUST UNITED AC 2017; 55:1683-1689. [DOI: 10.1515/cclm-2017-0044] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Accepted: 02/13/2017] [Indexed: 11/15/2022]
Abstract
Abstract:The introduction of “highly sensitive” cardiac troponin assays (hsTn) has reinforced the evidence that only serial testing incorporated in running algorithms allows a more accurate diagnosis of acute myocardial infarction. In this report, we consider the available evidence supporting the use of fast track protocols for ruling out and ruling in non-ST elevation myocardial infarction (NSTEMI) and compare it with the content of recently released guideline by the European Society of Cardiology, noting some uncomfortable aspects that need urgent clarification and/or revision. Firstly, the guideline drafters have to reconsider the available evidence that does not permit to assign the same class and level of evidence to the very well-validated 0–3 h algorithm and to the 0–1 h algorithm. In agreement with the validity of available data, the limitations of fast track protocols, in particular of the 0–1 h algorithm for NSTEMI rule-in, calls for caution. Secondly, as the current diagnostics guidance by the UK National Institute for Health and Care Excellence recommends, rapid diagnostic protocols should be performed only using well-validated hsTn; recommending the use of an assay before being commercially available is not fair and scientifically sound.
Collapse
|
47
|
Challenging the 99th percentile: A lower troponin cutoff leads to low mortality of chest pain patients. Int J Cardiol 2016; 232:289-293. [PMID: 28087181 DOI: 10.1016/j.ijcard.2016.12.167] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Revised: 12/19/2016] [Accepted: 12/25/2016] [Indexed: 11/17/2022]
Abstract
BACKGROUND Rule-out of non-ST-elevation myocardial infarction is based on consecutive measurements of cardiac troponins using the 99th percentile of the respective assay as cutoff. The new ESC guidelines alternatively offer rapid 1h algorithms with lower cutoffs than the 99th percentile for rule-out of non-ST-elevation myocardial infarction. We aimed to compare a recently introduced 1h algorithm based on a high-sensitivity cardiac troponin I (hs-TnI) cutoff of 6ng/L at 0h and 1h to the current standard of care using the 99th percentile (27ng/L) as cutoff with reference to follow-up events in a large chest pain cohort. METHODS Hs-TnI was measured at three time points (0h, 1h and 3h) in 1625 patients presenting with suspected myocardial infarction to the emergency department of the University-Medical Center Hamburg-Eppendorf. Seventy-five patients with ST-elevation myocardial infarction were excluded from the analysis. All-cause mortality, cardiac death, acute myocardial infarction, revascularization and cardiac rehospitalization after 12months were assessed. RESULTS Patients ruled out by the 1h algorithm showed significantly less cardiac rehospitalizations (12.84% vs. 17.66%; p<0.001), and overall mortality (1.30% vs 3.46%, p<0.001) compared to using the 99th percentile as cutoff. The majority of deaths were caused by non-cardiac reasons. Cardiac deaths were rare using the 1h algorithm (0.21%). CONCLUSION The commonly used 99th percentile as cutoff neglects patients with a high risk in the setting of acute chest pain. TRIAL REGISTRATION www.clinicaltrials.gov (NCT02355457).
Collapse
|
48
|
One Shot to Rule Out: Does the Limit of Detection of a High-Sensitivity Troponin Assay Hit the Mark? Clin Chem 2016; 63:21-23. [PMID: 27864385 DOI: 10.1373/clinchem.2016.266460] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Accepted: 11/01/2016] [Indexed: 11/06/2022]
|