1
|
Ebert N, Schaeffner E, Seegmiller JC, van Londen M, Bökenkamp A, Cavalier E, Delanaye P, Derain-Dubourg L, Eriksen BO, Indridason OS, Palsson R, Shafi T, Christensson A, Bevc S, Carrara F, Courbebaisse M, Dalton RN, van der Giet M, Melsom T, Methven S, Nordin G, Pottel H, Rule AD, Trillini M, White CA. Iohexol plasma clearance measurement protocol standardization for adults: a consensus paper of the European Kidney Function Consortium. Kidney Int 2024; 106:583-596. [PMID: 39097002 DOI: 10.1016/j.kint.2024.06.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 06/10/2024] [Accepted: 06/14/2024] [Indexed: 08/05/2024]
Abstract
International consensus supports the development of standardized protocols for measured glomerular filtration rate (mGFR) to facilitate the integration of mGFR testing in both clinical and research settings. To this end, the European Kidney Function Consortium convened an international group of experts with relevant experience in mGFR. The working group performed an extensive literature search to inform the development of recommendations for mGFR determination using 1-compartment plasma clearance models and iohexol as the exogenous filtration marker. Iohexol was selected as it is non-radio labeled, inexpensive, and safe, can be assayed at a central laboratory, and the other commonly used non-radio-labeled tracers have been (inulin) or are soon to be (iothalamate) discontinued. A plasma clearance model was selected over urine clearance as it requires no urine collection. A 1 compartment was preferred to 2 compartments as it requires fewer samples. The recommendations are based on published evidence complemented by expert opinion. The consensus paper covers practical advice for patients and health professionals, preparation, administration, and safety aspects of iohexol, laboratory analysis, blood sample collection and sampling times using both multiple and single-sample protocols, description of the mGFR mathematical calculations, as well as implementation strategies. Supplementary materials include patient and provider information sheets, standard operating procedures, a study protocol template, and support for mGFR calculation.
Collapse
Affiliation(s)
- Natalie Ebert
- Charité Universitätsmedizin Berlin, Institute of Public Health, Berlin, Germany
| | - Elke Schaeffner
- Charité Universitätsmedizin Berlin, Institute of Public Health, Berlin, Germany
| | - Jesse C Seegmiller
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Marco van Londen
- Division of Nephrology, Department of Internal Medicine, University Medical Center Groningen, Groningen, the Netherlands
| | - Arend Bökenkamp
- Department of Pediatric Nephrology, Amsterdam University Medical Centers, Amsterdam, the Netherlands
| | - Etienne Cavalier
- Department of Clinical Chemistry, University of Liège, Centre Hospitalier Universitaire du Sart-Tilman, Liège, Belgium
| | - Pierre Delanaye
- Department of Nephrology-Dialysis-Transplantation, University of Liège, Centre Hospitalier Universitaire du Sart-Tilman, Liège (ULiege), Belgium; Department of Nephrology-Dialysis-Apheresis, Hôpital Universitaire Carémeau, Nîmes, France
| | - Laurence Derain-Dubourg
- Service de Néphrologie, Dialyse, Hypertension et Exploration Fonctionnelle Rénale, Centre de Référence des Maladies Rénales Rares, Service de Néphrologie et Rhumatologie Pédiatriques, Hospices Civils de Lyon, Lyon, France
| | - Bjørn O Eriksen
- Section of Nephrology, University Hospital of North Norway and Metabolic and Renal Research Group, UiT, The Arctic University of Norway, Tromsø, Norway
| | | | - Runolfur Palsson
- Division of Nephrology, Landspitali University Hospital, Reykavik, Iceland; Faculty of Medicine, University of Iceland, Reykjavik, Iceland
| | - Tariq Shafi
- Division of Kidney Diseases, Hypertension and Transplantation, Department of Medicine, Houston Methodist Hospital, Houston, Texas, USA
| | - Anders Christensson
- Department of Nephrology, Skåne University Hospital, Lund University, Malmö, Sweden
| | - Sebastjan Bevc
- Department of Nephrology, Department of Pharmacology, University Medical Centre Maribor, Maribor, Slovenia; Faculty of Medicine, University of Maribor, Maribor, Slovenia
| | - Fabiola Carrara
- Clinical Research Center for Rare Diseases, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | - Marie Courbebaisse
- Université Paris Cité; Physiology Department, Hôpital Européen Georges-Pompidou, Assistance Publique-Hôpitaux de Paris, Paris, France
| | - R Neil Dalton
- The WellChild Laboratory, Evelina London Children's Hospital, London, UK
| | - Markus van der Giet
- Department of Nephrology, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Toralf Melsom
- Section of Nephrology, University Hospital of North Norway and Metabolic and Renal Research Group, UiT, The Arctic University of Norway, Tromsø, Norway
| | - Shona Methven
- Department of Renal Medicine, Aberdeen Royal Infirmary, Scotland, UK
| | | | - Hans Pottel
- Department of Public Health and Primary Care, Katholieke Universiteit Leuven Campus Kulak Kortrijk, Kortrijk, Belgium
| | - Andrew D Rule
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota, USA
| | - Matias Trillini
- Clinical Research Center for Rare Diseases, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | - Christine A White
- Department of Medicine, Queen's University, Kingston, Ontario, Canada.
| |
Collapse
|
2
|
Dorshow RB, Debreczeny MP, Goldstein SL, Shieh JJ. Clinical validation of the novel fluorescent glomerular filtration rate tracer agent relmapirazin (MB-102). Kidney Int 2024; 106:679-687. [PMID: 38964736 DOI: 10.1016/j.kint.2024.06.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 05/20/2024] [Accepted: 06/17/2024] [Indexed: 07/06/2024]
Abstract
The fluorescent compound relmapirazin has been rationally designed for use in point-of-care measurement of glomerular filtration rate (GFR), with attributes including negligible protein binding, negligible metabolites in vivo, negligible tubular secretion, and excellent chemical and photo stability. Twenty-four nonclinical assays were performed in accordance with FDA requirements yielding negligible toxicology concerns. Here, a clinical study was performed to validate relmapirazin as a GFR tracer in patients by comparison to iohexol. This was evaluated in 120 adults at three clinical sites with eGFR values ranging from normal to Stage 4 chronic kidney disease. Relmapirazin and iohexol were administered intravenously in consecutive boluses to each subject and serial blood samples obtained over the subsequent 12 hours. Plasma concentrations were measured and the corresponding plasma GFR for each agent was determined using a standard two-compartment pharmacokinetic assessment. Urine from each subject was collected for the entire 12-hour study period to measure the amount of administered dose appearing in the urine. A near perfect linear regression correlation was observed between the GFRs measured by these two tracers (r2=0.99). Bland-Altman analysis confirmed agreement between these two measures of GFR (limits of agreement -7.0 to +5.6 mL/min; mean of -0.7 mL/min). The GFR determined by relmapirazin was independent of GFR stratification by chronic kidney disease stage, and importantly by race. The percent of the administered relmapirazin dose recovered in the urine was greater than or equal to that of iohexol with no reported severe adverse events. Thus, relmapirazin may be used as a GFR tracer agent in humans.
Collapse
|
3
|
Jin Z, Huang R, Christensen P, Bertholf RL, Yi X. Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors. J Clin Med 2023; 12:6054. [PMID: 37762993 PMCID: PMC10532236 DOI: 10.3390/jcm12186054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 09/07/2023] [Accepted: 09/12/2023] [Indexed: 09/29/2023] Open
Abstract
BACKGROUND An accurate measurement of the glomerular filtration rate (GFR) is essential for detecting renal insufficiency in living kidney donors. Iohexol is a "near-ideal" exogenous filtration marker for GFR measurements that has attracted increasing interest in clinical practice because it is non-toxic, non-radioactive, readily available, and easy to measure. In this study, we aimed to set up a laboratory test to conveniently assess the plasma clearance of iohexol in living kidney donors. METHODS A workflow was established in the institution's infusion clinic to administer iohexol and to collect three timed blood samples from renal transplant donors. Iohexol was thereafter measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The serum proteins were precipitated and the supernatant containing iohexol was diluted prior to the LC-MS/MS analysis. The LC-MS/MS method was developed on a Thermo Vanquish UHPLC coupled with a TSQ Endura triple quadruple mass spectrometer with a total run time of 2.5 min. The analytical performance of the method was assessed. RESULTS The LC-MS/MS method demonstrated a good analytical performance. To calculate the iohexol clearance rate and the GFR, automated data integration and a result calculation were accomplished by using a custom Python script. Automated result reporting was achieved using a laboratory informatics system (LIS) vendor's direct media interface. CONCLUSIONS We developed and implemented a laboratory test to assess the plasma clearance of iohexol. A workflow was established in the hospital to reliably measure the GFR in living kidney donors, with a potential to be further expanded into other areas where an accurate GFR measurement is needed.
Collapse
Affiliation(s)
- Zhicheng Jin
- Department of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, TX 77030, USA
| | - Rongrong Huang
- Department of Pathology and Immunology, Baylor College of Medicine, Harris Health System Ben Taub Hospital, Houston, TX 77030, USA
| | - Paul Christensen
- Department of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, TX 77030, USA
- Department of Pathology and Laboratory Medicine, Weill Cornell Medical College, New York, NY 10065, USA
| | - Roger L. Bertholf
- Department of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, TX 77030, USA
- Department of Pathology and Laboratory Medicine, Weill Cornell Medical College, New York, NY 10065, USA
| | - Xin Yi
- Department of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, TX 77030, USA
- Department of Pathology and Laboratory Medicine, Weill Cornell Medical College, New York, NY 10065, USA
| |
Collapse
|
4
|
Ng DK, Furth SL, Warady BA, Crews DC, Seegmiller JC, Schwartz GJ. Self-reported Race, Serum Creatinine, Cystatin C, and GFR in Children and Young Adults With Pediatric Kidney Diseases: A Report From the Chronic Kidney Disease in Children (CKiD) Study. Am J Kidney Dis 2022; 80:174-185.e1. [PMID: 34974031 PMCID: PMC9243196 DOI: 10.1053/j.ajkd.2021.10.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 10/24/2021] [Indexed: 01/27/2023]
Abstract
RATIONALE & OBJECTIVE Recent reassessment of the use of race in estimated glomerular filtration rate (eGFR) in adults has instigated questions about the role of race in eGFR expressions for children. Little research has examined the associations of self-reported race with measured GFR (mGFR) adjusting for serum creatinine or cystatin C in children and young adults with chronic kidney disease (CKD). This study examined these associations and evaluated the performance of the previously published "U25" (under the age of 25 years) eGFR equations in a large cohort of children and young adults with CKD. STUDY DESIGN Observational cohort study. SETTING & PARTICIPANTS Participants in the Chronic Kidney Disease in Children (CKiD) study including 190 Black and 675 non-Black participants contributing 473 and 1,897 annual person-visits, respectively. EXPOSURE Self- or parental-reported race (Black, non-Black). Adjustment for serum creatinine or cystatin C, body size, and socioeconomic status. OUTCOME mGFR based on iohexol clearance. ANALYTICAL APPROACH Linear regression with generalized estimating equations, stratified by age (<6, 6-12, 12-18, and ≥18 years) incorporating serum creatinine or serum cystatin C. Contrasting performance in different self-reported racial groups of the U25 eGFR equations. RESULTS Self-reported Black race was significantly associated with 12.8% higher mGFR among children in regression models including serum creatinine. Self-reported Black race was significantly associated with 3.5% lower mGFR after adjustment for cystatin C overall but was not significant for those over 12 years. The results were similar after adjustment for body size and socioeconomic factors. The average of creatinine- and cystatin C-based U25 equations was unbiased by self-reported race groups. LIMITATIONS Small number of children < 6 years; lean body mass was estimated. CONCLUSIONS Differences in the creatinine-mGFR relationship by self-reported race were observed in children and young adults with CKD and were consistent with findings in adults. Smaller and opposite differences were observed for the cystatin C-mGFR relationship, especially in the younger age group. We recommend inclusion of children for future investigations of biomarkers to estimate GFR. Importantly, for GFR estimation among those under 25 years of age, the average of the new U25 creatinine and cystatin C equations without race coefficients yields unbiased estimates of mGFR.
Collapse
Affiliation(s)
- Derek K. Ng
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| | - Susan L. Furth
- Children’s Hospital of Philadelphia, Philadelphia, PA, USA,Department of Pediatrics, Division of Nephrology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Bradley A. Warady
- Division of Pediatric Nephrology, Children’s Mercy Kansas City, Kansas City, MO, USA
| | - Deidra C. Crews
- Division of Nephrology, Department of Medicine, Johns Hopkins School of Medicine, Baltimore, MD, USA
| | - Jesse C. Seegmiller
- Department of Laboratory Medicine and Pathology, School of Medicine, University of Minnesota, Minneapolis, MN
| | - George J. Schwartz
- Department of Pediatrics, University of Rochester Medical Center, Rochester, NY, USA
| | | |
Collapse
|
5
|
Gong K, Zou Y, Zhu H, Peng X, Qin D, Sun B, Wang X. Comparative study of plasma clearance of iohexol at different injection doses. Clin Chim Acta 2021; 525:34-39. [PMID: 34906558 DOI: 10.1016/j.cca.2021.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 11/25/2021] [Accepted: 12/08/2021] [Indexed: 11/03/2022]
Abstract
BACKGROUND Our goal was to compare the metabolic curves of plasma clearance of iohexol (ClIOH) at standard dose (5 ml) and contrast-level dose (50 ml). METHODS The concentration of iohexol was measured at fasting state and at nine different time periods after a single bolus of iohexol injection. The interval between the injection of the two doses was longer than 24 hrs. Using a multi-point method and a dual-sample method, ClIOH-M and ClIOH-D were calculated, and the correlation and consistency of ClIOH between the two doses were compared. RESULTS The metabolic curves of iohexol at the 5 ml and 50 ml injection were substantially identical. The correlation of ClIOH-M between the two doses was 0.930, the mean deviation was 1.3 ± 6.9 ml/min/1.73 m2. Taking ClIOH-5ml-M as the standard, the ClIOH-50ml-D at 2 h and 4 h had a correlation coefficient of 0.975, a mean deviation of 0.1 ± 5.3 ml/min/1.73 m2, and the concordances were 100% corresponding to P30, 88.9% corresponding to P10, and 77.8% corresponding to P5. CONCLUSION When a regular dose of iohexol is used for enhanced CT, ClIOH can be used for the measurement of GFR, and a proper time for blood collection can be 2 h and 4 h.
Collapse
Affiliation(s)
- Ke Gong
- Department of Clinical Laboratory, Civil Aviation General Hospital, Beijing, China; Peking University Civil Aviation School of Clinical Medicine, Beijing, China
| | - Yingshu Zou
- Beijing Institute of Medical Device Testing, Beijing, China; NMPA Key Laboratory for Quality Evaluation of In Vitro Diagnostics, Beijing, China
| | - Haifeng Zhu
- Department of Radiology, Civil Aviation General Hospital, Beijing, China; Peking University Civil Aviation School of Clinical Medicine, Beijing, China
| | - Xu Peng
- Beijing Institute of Medical Device Testing, Beijing, China; NMPA Key Laboratory for Quality Evaluation of In Vitro Diagnostics, Beijing, China
| | - Dongfang Qin
- Department of Clinical Laboratory, Civil Aviation General Hospital, Beijing, China; Peking University Civil Aviation School of Clinical Medicine, Beijing, China
| | - Bixuan Sun
- Department of Clinical Laboratory, Civil Aviation General Hospital, Beijing, China
| | - Xuejing Wang
- Department of Clinical Laboratory, Civil Aviation General Hospital, Beijing, China; Peking University Civil Aviation School of Clinical Medicine, Beijing, China.
| |
Collapse
|
6
|
Speeckaert MM, Seegmiller J, Glorieux G, Lameire N, Van Biesen W, Vanholder R, Delanghe JR. Measured Glomerular Filtration Rate: The Query for a Workable Golden Standard Technique. J Pers Med 2021; 11:949. [PMID: 34683089 PMCID: PMC8541429 DOI: 10.3390/jpm11100949] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 09/20/2021] [Accepted: 09/22/2021] [Indexed: 01/12/2023] Open
Abstract
Inulin clearance has, for a long time, been considered as the reference method to determine measured glomerular filtration rates (mGFRs). However, given the known limitations of the standard marker, serum creatinine, and of inulin itself, and the frequent need for accurate GFR estimations, several other non-radioactive (iohexol and iothalamate) and radioactive (51Cr-EDTA, 99mTc-DTPA, 125I iothalamate) exogenous mGFR filtration markers are nowadays considered the most accurate options to evaluate GFR. The availability of 51Cr-EDTA is limited, and all methods using radioactive tracers necessitate specific safety precautions. Serum- or plasma-based certified reference materials for iohexol and iothalamate and evidence-based protocols to accurately and robustly measure GFR (plasma vs. urinary clearance, single-sample vs. multiple-sample strategy, effect of sampling time delay) are lacking. This leads to substantial variation in reported mGFR results across studies and questions the scientific reliability of the alternative mGFR methods as the gold standard to evaluate kidney function. On top of the scientific discussion, regulatory issues are further narrowing the clinical use of mGFR methods. Therefore, this review is a call for standardization of mGFR in terms of three aspects: the marker, the analytical method to assess concentrations of that marker, and the procedure to determine GFR in practice. Moreover, there is also a need for an endogenous filtration marker or a panel of filtration markers from a single blood draw that would allow estimation of GFR as accurately as mGFR, and without the need for application of anthropometric, clinical, and demographic characteristics.
Collapse
Affiliation(s)
- Marijn M. Speeckaert
- Department of Nephrology, Ghent University Hospital, 9000 Ghent, Belgium; (G.G.); (N.L.); (W.V.B.); (R.V.)
- Research Foundation Flanders, 1000 Brussels, Belgium
| | - Jesse Seegmiller
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN 55455, USA;
| | - Griet Glorieux
- Department of Nephrology, Ghent University Hospital, 9000 Ghent, Belgium; (G.G.); (N.L.); (W.V.B.); (R.V.)
| | - Norbert Lameire
- Department of Nephrology, Ghent University Hospital, 9000 Ghent, Belgium; (G.G.); (N.L.); (W.V.B.); (R.V.)
| | - Wim Van Biesen
- Department of Nephrology, Ghent University Hospital, 9000 Ghent, Belgium; (G.G.); (N.L.); (W.V.B.); (R.V.)
| | - Raymond Vanholder
- Department of Nephrology, Ghent University Hospital, 9000 Ghent, Belgium; (G.G.); (N.L.); (W.V.B.); (R.V.)
| | - Joris R. Delanghe
- Department of Diagnostic Sciences, Ghent University, 9000 Ghent, Belgium;
| |
Collapse
|
7
|
Pierce CB, Muñoz A, Ng DK, Warady BA, Furth SL, Schwartz GJ. Age- and sex-dependent clinical equations to estimate glomerular filtration rates in children and young adults with chronic kidney disease. Kidney Int 2021; 99:948-956. [PMID: 33301749 PMCID: PMC9083470 DOI: 10.1016/j.kint.2020.10.047] [Citation(s) in RCA: 238] [Impact Index Per Article: 59.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 10/09/2020] [Accepted: 10/30/2020] [Indexed: 11/19/2022]
Abstract
Using data (2655 observations from 928 participants) from the Chronic Kidney Disease in Children Study, we developed and internally validated new glomerular filtration rate estimating equations for clinical use in children and young adults: two forms of K × [heigh(ht) / serum creatinine(sCr)] and two forms of K × [1 / cystatin C(cysC)]. For each marker, one equation used a sex-dependent K; in the other, K is sex-and age-dependent. Glomerular filtration rate (GFR) was measured directly by plasma iohexol disappearance. The equations using ht⁄sCr had sex-specific constants of 41.8 for males and 37.6 for females. In the age- dependent models, K increased monotonically for children 1-18 years old and was constant for young adults 18-25 years. For males, K ranged from 35.7 for one-year-olds to 50.8 for those 18 and older. For females, the values of K ranged from 33.1 to 41.4. Constant K values for cystatin-C equations were 81.9 for males and 74.9 for females. With age-dependency, K varied non-monotonically with the highest values at age 15 for males (K of 87.2) and 12 years for females (K of 79.9). Use of an age-dependent K with ht/sCr models reduced average bias, notably in young children and young adults; age-dependent cystatin-C models produced similar agreement to using a constant K in children under 18 years, but reduced bias in young adults. These age-dependent proposed equations were evaluated alongside estimated GFRs from 11 other published equations for pediatrics and young adults. Only our proposed equations yielded non- significant bias and within 30% accuracy values greater than 85% in both the pediatric and young adult subpopulations.
Collapse
Affiliation(s)
- Christopher B Pierce
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA.
| | - Alvaro Muñoz
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Derek K Ng
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Bradley A Warady
- Division of Pediatric Nephrology, Children's Mercy Kansas City, Kansas City, Missouri, USA
| | - Susan L Furth
- Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, and Division of Nephrology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - George J Schwartz
- Department of Pediatrics, Pediatric Nephrology, University of Rochester Medical Center, Rochester, New York, USA
| |
Collapse
|
8
|
Lucas GM, Atta MG, Zook K, Vaidya D, Tao X, Maier P, Schwartz GJ. Cross-Sectional and Longitudinal Performance of Creatinine- and Cystatin C-Based Estimating Equations Relative to Exogenously Measured Glomerular Filtration Rate in HIV-Positive and HIV-Negative Persons. J Acquir Immune Defic Syndr 2020; 85:e58-e66. [PMID: 33136753 PMCID: PMC8301492 DOI: 10.1097/qai.0000000000002471] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Reliable estimates of glomerular filtration rate (GFR) are important in the clinical management of HIV-positive patients. Data on the performance of widely used estimating equations (eGFR) relative to exogenously measured GFR are sparse in this population. METHODS We evaluated cross-sectional and longitudinal accuracy and bias of eGFR, based on creatinine and cystatin C, relative to disappearance of infused iohexol from plasma (iGFR) in a cohort of participants followed annually for up to 7 years. RESULTS A total of 222 HIV-positive and 139 HIV-negative participants contributed 1240 visits with valid iGFR and eGFR measures. Estimated GFR based on both creatinine and cystatin C performed the best. Estimated GFR based on creatinine alone overestimated iGFR by 9 mL·min·1.73 m on average and was significantly less accurate in HIV-positive than HIV-negative individuals. The performance of equations based on either creatinine alone or cystatin C alone were significantly affected by participant factors (eg, non-suppressed HIV RNA, nadir CD4 count, hepatitis C virus coinfection). The average iGFR slope was -4% per year in HIV-positive participants. In both HIV-positive and HIV-negative participants, eGFR slope measures were generally unbiased but inaccurate, with only 60%-74% of observations falling within ±5% points of iGFR slope. CONCLUSIONS Both creatinine and cystatin C have limitations as GFR indices in HIV-positive individuals. Estimated GFR based on both creatinine and cystatin C performed best in our study and may be preferred in HIV-positive persons with kidney disease or comorbidities that place them at high risk for kidney disease.
Collapse
Affiliation(s)
- Gregory M. Lucas
- Johns Hopkins University School of Medicine, Department of Medicine, Baltimore, MD 21287, United States
| | - Mohamed G. Atta
- Johns Hopkins University School of Medicine, Department of Medicine, Baltimore, MD 21287, United States
| | - Katie Zook
- Johns Hopkins University School of Medicine, Department of Medicine, Baltimore, MD 21287, United States
| | - Dhananjay Vaidya
- Johns Hopkins University School of Medicine, Department of Medicine, Baltimore, MD 21287, United States
| | - Xueting Tao
- Johns Hopkins University School of Medicine, Department of Medicine, Baltimore, MD 21287, United States
| | - Paula Maier
- University of Rochester Medical Center, Department of Pediatrics, Rochester, NY 14642, United States
| | - George J. Schwartz
- University of Rochester Medical Center, Department of Pediatrics, Rochester, NY 14642, United States
| |
Collapse
|
9
|
Ng DK, Levey AS, Shlipak MG, Muñoz A, Inker LA, Shafi T. Validation of a simple equation for glomerular filtration rate measurement based on plasma iohexol disappearance. Clin Kidney J 2020; 13:397-401. [PMID: 32699620 PMCID: PMC7367109 DOI: 10.1093/ckj/sfz083] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Accepted: 06/02/2019] [Indexed: 11/25/2022] Open
Abstract
Background A simple equation for glomerular filtration rate (GFR) measurement based on only plasma samples during the slow compartment after injection of iohexol was previously developed among children with chronic kidney disease and adult men with or at risk of HIV infection [Chronic Kidney Disease in Children (CKiD)-Multicenter AIDS Cohort Study (MACS) equation], but has not been externally validated. We aimed to evaluate the performance of the CKiD-MACS equation among elderly participants in the Multi-Ethnic Study of Atherosclerosis (MESA) cohort who underwent directly measured iohexol GFR. Methods Using data from 287 participants of the MESA-Kidney study who underwent a five-sample measured iohexol GFR (two and three samples in the fast and slow compartments, respectively), we assessed the performance of the CKiD-MACS equation using only plasma samples in the slow compartment by sex, race and age. Agreement was assessed by bias, correlation, proportion within 5 and 10%, and the root mean square error (RMSE). Results The average age and GFR of the participants were 71 years and 70.8 mL/min/1.73 m2, respectively, and 46% were black. The equation yielded excellent agreement within stratified groups with high correlation (>0.96), low bias (≤1.2 mL/min/1.73 m2) and low RMSE (<4.2 mL/min/1.73 m2). Conclusions The CKiD-MACS equation demonstrated valid GFR measurement using only samples in the slow compartment in this racially diverse, elderly population. While the equation yielded practically the same results as the original Brochner-Mortensen equation, the CKiD-MACS equation conforms to theoretical principles embedded in the two-compartment model of direct GFR measurement.
Collapse
Affiliation(s)
- Derek K Ng
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| | - Andrew S Levey
- Division of Nephrology, Tufts Medical Center, Boston, MA, USA
| | - Michael G Shlipak
- Kidney Health Research Collaborative, San Francisco VA Medical Center, University of California, San Francisco, CA, USA
| | - Alvaro Muñoz
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| | - Lesley A Inker
- Division of Nephrology, Tufts Medical Center, Boston, MA, USA
| | - Tariq Shafi
- Division of Nephrology, The University of Mississippi Medical Center, Jackson, MS, USA
| |
Collapse
|
10
|
Enhanced specificity due to method specific limits for relative ion intensities in a high-performance liquid chromatography – tandem mass spectrometry method for iohexol in human serum. ACTA ACUST UNITED AC 2020; 58:709-718. [DOI: 10.1515/cclm-2019-1001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Accepted: 01/20/2020] [Indexed: 12/26/2022]
Abstract
AbstractBackgroundAccurate assessment of kidney function is needed for a variety of clinical indications and for research. The measurement of the serum clearance of iohexol has emerged as a feasible method to reach this objective. We report the analytical validation and clinical application of a new high-performance liquid chromatography (HPLC) – tandem mass spectrometry (MS/MS) assay to quantify iohexol in human serum. Specificity was enhanced due to the use of method specific acceptance limits for relative ion (RI) intensities.MethodsThe internal standard ioversol was added to 50 μL serum prior to protein precipitation with methanol. Linear gradient elution was performed on a Waters Oasis® HLB column. Three transitions for both iohexol and ioversol were monitored allowing calculation of RIs. Measurements acquired during method validation were used as a training set to establish stricter acceptance criteria for RIs which were then tested retrospectively on clinical routine measurements (86 measurements) and on mathematically simulated interferences.ResultsThe method was linear between 5.0 μg/mL (lower limit of quantification [LLOQ]) and 100.3 μg/mL iohexol. Intraday and interday imprecision were ≤2.6% and ≤3.2%, respectively. Bias was −1.6% to 1.5%. All validation criteria were met, including selectivity, recovery, extraction efficiency and matrix effects. Retrospectively acceptance limits for RIs could be narrowed to ±4 relative standard deviations of the corresponding RIs in the training set. The new limits resulted in an enhanced sensitivity for the simulated interferences.ConclusionsCriteria for validation were met and the assay is now used in our clinical routine diagnostics and in research.
Collapse
|
11
|
Chen N, Shi H, Zhang L, Zuo L, Xie J, Xie D, Karger AB, Miao S, Ren H, Zhang W, Wang W, Pan Y, Minji W, Sui Z, Okparavero A, Simon A, Chaudhari J, Eckfeldt JH, Inker LA, Levey AS. GFR Estimation Using a Panel of Filtration Markers in Shanghai and Beijing. Kidney Med 2020; 2:172-180. [PMID: 32734236 PMCID: PMC7380432 DOI: 10.1016/j.xkme.2019.11.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
RATIONALE & OBJECTIVES Estimated glomerular filtration rate (eGFR) using creatinine and cystatin C (eGFRcr-cys) may be less accurate compared to measured GFR (mGFR) in China than in North America, Europe, and Australia due to variation across regions in their non-GFR determinants. The non-GFR determinants of β2-microglobulin (B2M) and β-trace protein (BTP) differ from those of creatinine and cystatin C. Thus, the average eGFR using all 4 markers (eGFRavg) could be more accurate than eGFRcr-cys in China. STUDY DESIGN Diagnostic test study. SETTING & PARTICIPANTS 1,066 participants in Shanghai and Beijing with creatinine and cystatin C and 666 participants with all 4 filtration markers. TESTS COMPARED Index tests were previously developed equations for eGFR using creatinine, cystatin C, B2M, and BTP and combinations. The reference test was mGFR using plasma clearance of iohexol. We compared the performance of eGFRavg to eGFRcr-cys using the proportion of participants with errors in eGFR >30% of mGFR (1 - P30) and root mean square error (RMSE) of the regression of eGFR on mGFR on the logarithmic scale. We also compared classification and reclassification of mGFR categories using eGFRavg compared to eGFRcr-cys. OUTCOMES Accuracy was significantly better for eGFRavg (1 - P30 of 10.4% and RMSE of 0.214) compared to eGFRcr-cys (1 - P30 of 13.8% and RMSE of 0.232; P = 0.004 and P = 0.006, respectively). However, improvements in accuracy did not generally translate into significant improvement in classification or reclassification of mGFR categories. LIMITATIONS Study population may not be generalizable to clinical settings other than large urban medical centers in China. CONCLUSIONS A panel of endogenous filtration markers including B2M and BTP in addition to creatinine and cystatin C may improve GFR estimation in China. Further study is necessary to determine whether GFR estimation using B2M and BTP can be improved and whether these improvements lead to useful clinical applications.
Collapse
Affiliation(s)
- Nan Chen
- Department of Nephrology, Institute of Nephrology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Hao Shi
- Department of Nephrology, Institute of Nephrology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Luxia Zhang
- Renal Division, Department of Medicine, Peking University First Hospital, Peking University Institute of Nephrology, Beijing, China
- Peking University, Center for Data Science in Health and Medicine, Beijing, China
| | - Li Zuo
- Department of Nephrology, Peking University People's Hospital, Beijing, China
| | - Jingyuan Xie
- Department of Nephrology, Institute of Nephrology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Danshu Xie
- Department of Nephrology, Institute of Nephrology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Amy B. Karger
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN
| | - Shiyuan Miao
- Division of Nephrology, Tufts Medical Center, Boston, MA
| | - Hong Ren
- Department of Nephrology, Institute of Nephrology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Wen Zhang
- Department of Nephrology, Institute of Nephrology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Weiming Wang
- Department of Nephrology, Institute of Nephrology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yujing Pan
- Renal Division, Department of Medicine, Peking University First Hospital, Peking University Institute of Nephrology, Beijing, China
| | - Wei Minji
- Institute of Clinical Pharmacology, Peking University First Hospital, Beijing, China
| | - Zhun Sui
- Department of Nephrology, Peking University People's Hospital, Beijing, China
| | | | - Andrew Simon
- Division of Nephrology, Tufts Medical Center, Boston, MA
| | - Juhi Chaudhari
- Division of Nephrology, Tufts Medical Center, Boston, MA
| | - John H. Eckfeldt
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN
| | | | | |
Collapse
|
12
|
Eriksen BO, Schaeffner E, Melsom T, Ebert N, van der Giet M, Gudnason V, Indridasson OS, Karger AB, Levey AS, Schuchardt M, Sørensen LK, Palsson R. Comparability of Plasma Iohexol Clearance Across Population-Based Cohorts. Am J Kidney Dis 2019; 76:54-62. [PMID: 31879216 DOI: 10.1053/j.ajkd.2019.10.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 10/05/2019] [Indexed: 11/11/2022]
Abstract
RATIONALE & OBJECTIVE Glomerular filtration rate (GFR) estimation based on creatinine or cystatin C level is currently the standard method for assessing GFR in epidemiologic research and clinical trials despite several important and well-known limitations. Plasma iohexol clearance has been proposed as an inexpensive method for measuring GFR that could replace estimated GFR in many research projects. However, lack of standardization for iohexol assays and the use of different protocols such as single- and multiple-sample methods could potentially hamper comparisons across studies. We compared iohexol assays and GFR measurement protocols in 3 population-based European cohorts. STUDY DESIGN Cross-sectional investigation. SETTING & PARTICIPANTS Participants in the Age, Gene/Environment Susceptibility-Kidney Study (AGES-Kidney; n=805), the Berlin Initiative Study (BIS, n=570), and the Renal Iohexol Clearance Survey Follow-up Study (RENIS-FU; n=1,324). TESTS COMPARED High-performance liquid chromatography analyses of iohexol. Plasma iohexol clearance calculated using single- versus multiple-sample protocols. OUTCOMES Measures of agreement between methods. RESULTS Frozen samples from the 3 studies were obtained and iohexol concentrations were remeasured in the laboratory at the University Hospital of North Norway. Lin's concordance correlation coefficient ρ was>0.96 and Cb (accuracy) was>0.99 for remeasured versus original serum iohexol concentrations in all 3 cohorts, and Passing-Bablok regression did not find differences between measurements, except for a slope of 1.025 (95% CI, 1.006-1.046) for the log-transformed AGES-Kidney measurements. The multiple-sample iohexol clearance measurements in AGES-Kidney and BIS were compared with single-sample GFRs derived from the same iohexol measurements. Mean bias for multiple-sample relative to single-sample GFRs in AGES-Kidney and BIS were-0.25 and-0.15mL/min, and 99% and 97% of absolute differences were within 10% of the multiple-sample result, respectively. LIMITATIONS Lack of comparison with an independent gold-standard method. CONCLUSIONS Agreement between the iohexol assays and clearance protocols in the 3 investigated cohorts was substantial. Our findings indicate that plasma iohexol clearance measurements can be compared across these studies.
Collapse
Affiliation(s)
- Bjørn O Eriksen
- Metabolic and Renal Research Group, UiT The Arctic University of Norway, Tromsø, Norway.
| | - Elke Schaeffner
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt Universität zu Berlin, and Berlin Institute of Health, Institute of Public Health, Berlin, Germany
| | - Toralf Melsom
- Metabolic and Renal Research Group, UiT The Arctic University of Norway, Tromsø, Norway
| | - Natalie Ebert
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt Universität zu Berlin, and Berlin Institute of Health, Institute of Public Health, Berlin, Germany
| | - Markus van der Giet
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt Universität zu Berlin; Berlin Institute of Health, Department of Nephrology, Hindenburgdamm 30, Berlin, Germany
| | - Vilmundur Gudnason
- Icelandic Heart Association, Reykjavik, Iceland; University of Iceland, Reykjavik, Iceland
| | - Olafur S Indridasson
- Division of Nephrology, Landspitali-The National University Hospital of Iceland, Reykjavik, Iceland
| | - Amy B Karger
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN
| | - Andrew S Levey
- Division of Nephrology, Tufts Medical Center, Boston, MA
| | - Mirjam Schuchardt
- Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt Universität zu Berlin; Berlin Institute of Health, Department of Nephrology, Hindenburgdamm 30, Berlin, Germany
| | - Liv K Sørensen
- Department of Medical Biochemistry, University Hospital of North Norway, Tromsø, Norway
| | - Runolfur Palsson
- University of Iceland, Reykjavik, Iceland; Division of Nephrology, Landspitali-The National University Hospital of Iceland, Reykjavik, Iceland
| |
Collapse
|
13
|
Ng DK, Schwartz GJ, Schneider MF, Furth SL, Warady BA. Combination of pediatric and adult formulas yield valid glomerular filtration rate estimates in young adults with a history of pediatric chronic kidney disease. Kidney Int 2018; 94:170-177. [PMID: 29735307 PMCID: PMC6015546 DOI: 10.1016/j.kint.2018.01.034] [Citation(s) in RCA: 59] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2017] [Revised: 01/19/2018] [Accepted: 01/25/2018] [Indexed: 02/06/2023]
Abstract
As patients with chronic kidney disease (CKD) transition from pediatric nephrology care to adult care, their kidney function is clinically assessed by estimated glomerular filtration rate (eGFR) using both pediatric and adult equations, which may not be congruent. Here we evaluated commonly used eGFR equations and directly measured iohexol GFR (iGFR) among participants between ages 18 and 26 with a diagnosis of pediatric CKD in the Chronic Kidney Disease in Children (CKiD) cohort. The bedside serum creatinine (SCr)-only equation (CKiDSCr), the SCr-only CKD-EPI (CKD-EPISCr), the cystatin C (Cys)-only CKD-EPI (CKD-EPICys) and the combined SCr and Cys CKD-EPI (CKD-EPISCr-Cys) were compared with a) 279 measured iGFRs obtained from 187 participants and b) 548 eGFRs from the SCr and Cys-based CKiD equation (CKiDSCr-Cys) obtained from 219 participants. Among emerging adults with a median iGFR of 49 ml/min/1.73m2, the CKiDSCr-Cys equation had low bias (+1.5 ml/min/1.73m2) and high correlation (0.94), while CKiDSCr underestimated iGFR and CKiDSCr-Cys (-5.6 and -7.4 ml/min/1.73m2, respectively) and CKD-EPISCr had an overestimation bias (+8.2 and +6.1 ml/min/1.73m2, respectively). However, the CKD-EPICys and CKD-EPISCr-Cys exhibited strong agreement with both iGFR and CKiDSCr-Cys. GFR may also be validly estimated in this population by taking the simple average of CKiDSCr and CKD-EPISCr (average bias +1.3 compared to iGFR and -0.6 compared to CKiDSCr-Cys). Clinicians should be aware that individually the pediatric and adult SCr-based estimates of GFR had large discrepancies among emerging adults with pediatric CKD. Thus, when cystatin C is not available, we recommend the average of pediatric and adult SCr-based eGFR as a valid tool for clinical use.
Collapse
Affiliation(s)
- Derek K Ng
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA.
| | - George J Schwartz
- Department of Pediatrics, Division of Pediatric Nephrology, University of Rochester Medical Center, Rochester, New York, USA
| | - Michael F Schneider
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Susan L Furth
- Department of Pediatrics, Division of Nephrology, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA; Center for Clinical Epidemiology and Biostatistics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Bradley A Warady
- Division of Pediatric Nephrology, Children's Mercy Kansas City, Kansas City, Missouri, USA
| |
Collapse
|