Chiron AS, Locher L, Sarthou A, Gleizes A, Krzysiek R, Chretien P, Hacein-Bey-Abina S. Evaluation of analytical performance of AQUIOS CL flow cytometer and method comparison with bead-based flow cytometry methods. Clin Chem Lab Med 2024; 0:cclm-2023-1498. [PMID: 38584471 DOI: 10.1515/cclm-2023-1498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Accepted: 03/06/2024] [Indexed: 04/09/2024]
Abstract
OBJECTIVES Given that method validation is mandatory for compliance with the International Organization for Standardization (ISO) 15,189 standard requirements, we evaluated the analytical performance of the AQUIOS CL system (Beckman Coulter) and compared it with two bead-based flow cytometry (FCM) protocols (BD FACSCAntoTM-II and Beckman Coulter DxFLEX). There are no comparative literature data on standardized protocols for counting lymphocyte subsets on the new-generation cytometer DxFLEX. METHODS We evaluated the AQUIOS CL's performance with regard to accuracy, linearity and stability by using dedicated control cell samples and patient samples. We also compared the lymphocyte counts measured on the AQUIOS CL (n=69 samples) with those measured on the BD FACSCAntoTM-II and DxFLEX FCM systems. For 61 samples, FCM results were compared with those measured on the XN-3000 Sysmex hematology analyzer. RESULTS AQUIOS CL showed acceptable performance - even outside the manufacturer's quantification ranges- and strong correlations with bead-based FCM methods. The FCM techniques and the XN-3000 gave similar absolute lymphocyte counts, although values in samples with intense lymphocytosis (B cell lymphoma/leukemia) were underestimated. CONCLUSIONS The AQUIOS CL flow cytometer is a time-saving, single-platform system with good performance, especially when the manufacturer's instructions for use are followed. However, AQUIOS CL's possible limitations and pitfalls impose validation of a bead-based FCM method for immunophenotyping verification or as a back-up system. Although the DxFLEX flow cytometer is more time-consuming to use, it can provide standardized lymphocyte subset counts in case of aberrant results on AQUIOS CL or in the event of equipment failure.
Collapse
Affiliation(s)
- Andrada S Chiron
- Clinical Immunology Laboratory, Groupe Hospitalier Universitaire Paris Saclay, Hôpital Bicêtre, Assistance Publique-Hôpitaux de Paris, Le Kremlin-Bicêtre, France
- UTCBS, Unité des technologies Chimiques et Biologiques pour la Santé, Université Paris Cité, Paris, France
| | - Lucy Locher
- Clinical Immunology Laboratory, Groupe Hospitalier Universitaire Paris Saclay, Hôpital Bicêtre, Assistance Publique-Hôpitaux de Paris, Le Kremlin-Bicêtre, France
| | - Aurélie Sarthou
- Clinical Immunology Laboratory, Groupe Hospitalier Universitaire Paris Saclay, Hôpital Bicêtre, Assistance Publique-Hôpitaux de Paris, Le Kremlin-Bicêtre, France
| | - Aude Gleizes
- Clinical Immunology Laboratory, Groupe Hospitalier Universitaire Paris Saclay, Hôpital Bicêtre, Assistance Publique-Hôpitaux de Paris, Le Kremlin-Bicêtre, France
- UTCBS, Unité des technologies Chimiques et Biologiques pour la Santé, Université Paris Cité, Paris, France
| | - Roman Krzysiek
- Clinical Immunology Laboratory, Groupe Hospitalier Universitaire Paris Saclay, Hôpital Bicêtre, Assistance Publique-Hôpitaux de Paris, Le Kremlin-Bicêtre, France
- Inflammation, Microbiome and Immunosurveillance, Orsay, UMR-996 INSERM, Paris-Saclay University, Orsay, France
| | - Pascale Chretien
- Clinical Immunology Laboratory, Groupe Hospitalier Universitaire Paris Saclay, Hôpital Bicêtre, Assistance Publique-Hôpitaux de Paris, Le Kremlin-Bicêtre, France
- UTCBS, Unité des technologies Chimiques et Biologiques pour la Santé, Université Paris Cité, Paris, France
| | - Salima Hacein-Bey-Abina
- Clinical Immunology Laboratory, Groupe Hospitalier Universitaire Paris Saclay, Hôpital Bicêtre, Assistance Publique-Hôpitaux de Paris, Le Kremlin-Bicêtre, France
- UTCBS, Unité des technologies Chimiques et Biologiques pour la Santé, Université Paris Cité, Paris, France
| |
Collapse
|
2
|
Callebaut K, Gijbels E, Vanbesien J, Deeren D, Van Droogenbroeck J, Emmerechts J, Moreau E. Evaluation of AQUIOS STEM, a novel method for automated CD34+ stem cell enumeration using flow cytometry. Int J Lab Hematol 2024. [PMID: 38421076 DOI: 10.1111/ijlh.14253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 02/04/2024] [Indexed: 03/02/2024]
Abstract
OBJECTIVES Hematopoietic stem cell transplantation (HSCT) is a potentially curative treatment for various diseases. The measurement of CD34+ cells is crucial to schedule the peripheral blood stem cell collection and assess the engraftment potential of the apheresis product. The AQUIOS STEM system has been introduced as a novel application on the AQUIOS CL, a fully automated flow cytometer, for the enumeration of CD34+ hematopoietic progenitor cells (HPCs) in accordance with the The International Society for Hematotherapy and Graft Engineering guidelines. This study aimed to assess the potential of the novel AQUIOS STEM system versus currently used systems including the FACSCanto-II and the FACS Lyric flow cytometer in a multicenter study. METHODS A total of 91 samples were used for the validation of the AQUOIS STEM system, including an analytical performance evaluation by means of assessing precision, sample stability, intersample carryover, and linearity and a method comparison with the present FACS systems in use to assess analytical and clinical decision agreement. RESULTS Results showed excellent precision, with coefficient of variations <15% for dedicated quality control material and patient samples. There was no significant carry over. The fresh apheresis samples were stable when stored overnight at room temperature and at 4°C. Analytical comparison with the current systems demonstrated good correlation in peripheral blood, and minimal, clinically neglectable systematic and proportional bias in fresh apheresis products but a low correlation coefficient in cryopreserved products. CONCLUSIONS The STEM system on AQUIOS CL allows automated enumeration of CD34+ stem cells, demonstrating good analytical performance and promising overall outcomes in peripheral blood and fresh apheresis products.
Collapse
Affiliation(s)
- Kim Callebaut
- AZ Delta Medical Laboratories, AZ Delta General Hospital, Roeselare, Belgium
| | - Eva Gijbels
- Department of Laboratory Medicine, AZ Sint-Jan Hospital Brugge, Brugge, Belgium
| | - Jonathan Vanbesien
- AZ Delta Medical Laboratories, AZ Delta General Hospital, Roeselare, Belgium
| | - Dries Deeren
- AZ Delta Clinical Haematology, AZ Delta General Hospital, Roeselare, Belgium
| | | | - Jan Emmerechts
- Department of Laboratory Medicine, AZ Sint-Jan Hospital Brugge, Brugge, Belgium
| | - Elisabeth Moreau
- AZ Delta Medical Laboratories, AZ Delta General Hospital, Roeselare, Belgium
| |
Collapse
|
3
|
Lemoine L, Malcus C, Poitevin-Later F, Venet F, Monneret G, Gossez M. Cross-sectional reassessment after 4 years of clinical routine use of AQUIOS CL for absolute T cell quantitation in a university hospital. CYTOMETRY. PART B, CLINICAL CYTOMETRY 2022; 102:390-399. [PMID: 35437910 DOI: 10.1002/cyto.b.22069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 03/01/2022] [Accepted: 03/31/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND We had previously reported appropriate performances of automated AQUIOS CL cytometer (Beckman Coulter) for regulatory approval of absolute T cell enumeration. However, after 4 years of routine use, we still observed recurrent histogram anomalies that may affect both absolute values and T cell subset percentages results. The objective of the current study was thus to perform a cross-sectional evaluation of these graphical anomalies within a university hospital context, to assess their influence on results and ultimately to propose a standardized decision tree to circumvent graphical disturbances at the time of results validation. METHODS Eight hundred and sixty-two blood samples were prospectively analyzed on AQUIOS CL. Results were compared to (i) lymphocyte values from complete blood count; (ii) results from manual staining and analysis on Navios cytometer (Beckman Coulter); (iii) results after washing step and reacquisition on AQUIOS CL. RESULTS Nearly 75% analyses did not show any graphical anomaly. 20% had single anomaly on "Lymphs (45)" or "Lymphs EV" regions influencing T cells percentages and requiring manual re-gating of "CD3- capture" region. 5% showed concomitant "Lymphs EV" and "Lymphs (45)" anomalies influencing both T cell percentages and absolute counting and requiring additional staining and analysis on Navios. Finally, <1% presented with anomaly on "CD4/CD8" histogram or "CD3+ All" region, influencing both T cell percentages and absolute counting. CONCLUSIONS Around 25% AQUIOS CL results were flawed due to gating anomalies. In <5% cases, additional back-up procedures should be undertaken to ensure results validity. A simple decision-tree may help in guiding validation process.
Collapse
Affiliation(s)
- Léa Lemoine
- Hospices Civils de Lyon, Edouard Herriot Hospital, Immunology Laboratory, Lyon, France
| | - Christophe Malcus
- Hospices Civils de Lyon, Edouard Herriot Hospital, Immunology Laboratory, Lyon, France
| | | | - Fabienne Venet
- Hospices Civils de Lyon, Edouard Herriot Hospital, Immunology Laboratory, Lyon, France
- Université Claude Bernard Lyon 1, Lyon, France
| | - Guillaume Monneret
- Hospices Civils de Lyon, Edouard Herriot Hospital, Immunology Laboratory, Lyon, France
- Université Claude Bernard Lyon 1, Lyon, France
| | - Morgane Gossez
- Hospices Civils de Lyon, Edouard Herriot Hospital, Immunology Laboratory, Lyon, France
- Université Claude Bernard Lyon 1, Lyon, France
| |
Collapse
|
4
|
Wallace PK. Issue Highlights-September 2022. CYTOMETRY. PART B, CLINICAL CYTOMETRY 2022; 102:337-341. [PMID: 36106576 DOI: 10.1002/cyto.b.22091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
|
5
|
Hwang SH, Yang JJ, Oh YH, Ko DH, Sung H, Cho YU, Jang S, Park CJ, Oh HB. Microparticle-tagged image-based cell counting (ImmunoSpin) for CD4 + T cells. Mikrochim Acta 2021; 188:431. [PMID: 34822013 PMCID: PMC8616869 DOI: 10.1007/s00604-021-05070-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Accepted: 10/15/2021] [Indexed: 11/25/2022]
Abstract
Affordable point-of-care (POC) CD4 + T lymphocyte counting techniques have been developed as alternatives to flow cytometry-based instruments caring for patients with human immunodeficiency virus (HIV)-1. However, POC CD4 enumeration technologies can be inaccurate. Here, we developed a microparticle-based visual detector of CD4 + T lymphocytes (ImmunoSpin) using microparticles conjugated with anti-CD4 antibodies, independent of microfluidic or fluorescence detection systems. Visual enumeration of CD4 + T cells under conventional light microscope was accurate compared to flow cytometry. Microparticle-tagged CD4 + T cells were well-recognized under a light microscope. ImmunoSpin showed very good precision (coefficients of variation of ImmunoSpin were ≤ 10%) and high correlation with clinical-grade flow cytometry for the enumeration of CD4 + T cells (y = 0.4232 + 0.9485 × for the %CD4 + T cell count, R2 = 0.99). At thresholds of 200 and 350 cells/µL, there was no misclassification of the ImmunoSpin system compared to the reference flow cytometry. ImmunoSpin showed clear differential classification of CD4 + T lymphocytes from granulocytes and monocytes. Because non-fluorescence microparticle-tags and cytospin slides are used in ImmunoSpin, they can be applied to an automatic digital image analyzer. Slide preparation allows long-term storage, no analysis time limitations, and image transfer in remote areas.
Collapse
Affiliation(s)
- Sang-Hyun Hwang
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
- Asan Institute for Life Sciences, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - John Jeongseok Yang
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Yoon-Hee Oh
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Dae-Hyun Ko
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Heungsup Sung
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Young-Uk Cho
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Seongsoo Jang
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Chan-Jeoung Park
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Heung-Bum Oh
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea.
| |
Collapse
|
6
|
Shi J, Mu RQ, Wang P, Geng WQ, Jiang YJ, Zhao M, Shang H, Zhang ZN. The development of autoverification system of lymphocyte subset assays on the flow cytometry platform. Clin Chem Lab Med 2021; 60:92-100. [PMID: 34533003 DOI: 10.1515/cclm-2021-0736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 09/04/2021] [Indexed: 11/15/2022]
Abstract
OBJECTIVES Peripheral blood lymphocyte subsets are important parameters for monitoring immune status; however, lymphocyte subset detection is time-consuming and error-prone. This study aimed to explore a highly efficient and clinically useful autoverification system for lymphocyte subset assays performed on the flow cytometry platform. METHODS A total of 94,402 lymphocyte subset test results were collected. To establish the limited-range rules, 80,427 results were first used (69,135 T lymphocyte subset tests and 11,292 NK, B, T lymphocyte tests), of which 15,000 T lymphocyte subset tests from human immunodeficiency virus (HIV) infected patients were used to set customized limited-range rules for HIV infected patients. Subsequently, 13,975 results were used for historical data validation and online test validation. RESULTS Three key autoverification rules were established, including limited-range, delta-check, and logical rules. Guidelines for addressing the issues that trigger these rules were summarized. The historical data during the validation phase showed that the total autoverification passing rate of lymphocyte subset assays was 69.65% (6,941/9,966), with a 67.93% (5,268/7,755) passing rate for T lymphocyte subset tests and 75.67% (1,673/2,211) for NK, B, T lymphocyte tests. For online test validation, the total autoverification passing rate was 75.26% (3,017/4,009), with 73.23% (2,191/2,992) for the T lymphocyte subset test and 81.22% (826/1,017) for the NK, B, T lymphocyte test. The turnaround time (TAT) was reduced from 228 to 167 min using the autoverification system. CONCLUSIONS The autoverification system based on the laboratory information system for lymphocyte subset assays reduced TAT and the number of error reports and helped in the identification of abnormal cell populations that may offer clues for clinical interventions.
Collapse
Affiliation(s)
- Jue Shi
- NHC Key Laboratory of AIDS Immunology (China Medical University), National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University, Shenyang, P. R. China.,Key Laboratory of AIDS Immunology, Chinese Academy of Medical Sciences, Shenyang, P. R. China
| | - Run-Qing Mu
- Department of Laboratory Medicine, National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University, Shenyang, P. R. China
| | - Pan Wang
- NHC Key Laboratory of AIDS Immunology (China Medical University), National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University, Shenyang, P. R. China.,Key Laboratory of AIDS Immunology, Chinese Academy of Medical Sciences, Shenyang, P. R. China
| | - Wen-Qing Geng
- NHC Key Laboratory of AIDS Immunology (China Medical University), National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University, Shenyang, P. R. China.,Key Laboratory of AIDS Immunology, Chinese Academy of Medical Sciences, Shenyang, P. R. China
| | - Yong-Jun Jiang
- NHC Key Laboratory of AIDS Immunology (China Medical University), National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University, Shenyang, P. R. China.,Key Laboratory of AIDS Immunology, Chinese Academy of Medical Sciences, Shenyang, P. R. China
| | - Min Zhao
- Department of Laboratory Medicine, National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University, Shenyang, P. R. China
| | - Hong Shang
- NHC Key Laboratory of AIDS Immunology (China Medical University), National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University, Shenyang, P. R. China.,Key Laboratory of AIDS Immunology, Chinese Academy of Medical Sciences, Shenyang, P. R. China.,Department of Laboratory Medicine, National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University, Shenyang, P. R. China
| | - Zi-Ning Zhang
- NHC Key Laboratory of AIDS Immunology (China Medical University), National Clinical Research Center for Laboratory Medicine, The First Affiliated Hospital of China Medical University, Shenyang, P. R. China.,Key Laboratory of AIDS Immunology, Chinese Academy of Medical Sciences, Shenyang, P. R. China
| |
Collapse
|
7
|
Pfeifer ND, Lo A, Bourdet DL, Colley K, Singh D. Phase I study in healthy participants to evaluate safety, tolerability, and pharmacokinetics of inhaled nezulcitinib, a potential treatment for COVID-19. Clin Transl Sci 2021; 14:2556-2565. [PMID: 34318597 PMCID: PMC8444931 DOI: 10.1111/cts.13123] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 06/29/2021] [Accepted: 07/12/2021] [Indexed: 12/12/2022] Open
Abstract
Nezulcitinib (TD‐0903), a lung‐selective pan–Janus‐associated kinase (JAK) inhibitor designed for inhaled delivery, is under development for treatment of acute lung injury associated with coronavirus disease 2019 (COVID‐19). This two‐part, double‐blind, randomized, placebo‐controlled, single ascending dose (part A) and multiple ascending dose (part B) phase I study evaluated the safety, tolerability, and pharmacokinetics (PK) of nezulcitinib in healthy participants. Part A included three cohorts randomized 6:2 to receive a single inhaled dose of nezulcitinib (1, 3, or 10 mg) or matching placebo. Part B included three cohorts randomized 8:2 to receive inhaled nezulcitinib (1, 3, or 10 mg) or matching placebo for 7 days. The primary outcome was nezulcitinib safety and tolerability assessed from treatment‐emergent adverse events (TEAEs). The secondary outcome was nezulcitinib PK. All participants completed the study. All TEAEs were mild or moderate in severity, and none led to treatment discontinuation. Overall (area under the plasma concentration‐time curve) and peak (maximal plasma concentration) plasma exposures of nezulcitinib were low and increased in a dose‐proportional manner from 1 to 10 mg in both parts, with no suggestion of clinically meaningful drug accumulation. Maximal plasma exposures were below levels expected to result in systemic target engagement, consistent with a lung‐selective profile. No reductions in natural killer cell counts were observed, consistent with the lack of a systemic pharmacological effect and the observed PK. In summary, single and multiple doses of inhaled nezulcitinib at 1, 3, and 10 mg were well‐tolerated in healthy participants, with dose‐proportional PK supporting once‐daily administration.
Collapse
Affiliation(s)
- Nathan D Pfeifer
- Theravance Biopharma US, Inc., South San Francisco, California, USA
| | - Arthur Lo
- Theravance Biopharma US, Inc., South San Francisco, California, USA
| | - David L Bourdet
- Theravance Biopharma US, Inc., South San Francisco, California, USA
| | - Kenneth Colley
- Theravance Biopharma US, Inc., South San Francisco, California, USA
| | - Dave Singh
- Medicines Evaluation Unit, University of Manchester, Manchester University, Manchester, UK
| |
Collapse
|
8
|
Hesselink L, Spijkerman R, de Fraiture E, Bongers S, Van Wessem KJP, Vrisekoop N, Koenderman L, Leenen LPH, Hietbrink F. New automated analysis to monitor neutrophil function point-of-care in the intensive care unit after trauma. Intensive Care Med Exp 2020; 8:12. [PMID: 32172430 PMCID: PMC7072076 DOI: 10.1186/s40635-020-0299-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2019] [Accepted: 02/26/2020] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Patients often develop infectious complications after severe trauma. No biomarkers exist that enable early identification of patients who are at risk. Neutrophils are important immune cells that combat these infections by phagocytosis and killing of pathogens. Analysis of neutrophil function used to be laborious and was therefore not applicable in routine diagnostics. Hence, we developed a quick and point-of-care method to assess a critical part of neutrophil function, neutrophil phagosomal acidification. The aim of this study was to investigate whether this method was able to analyze neutrophil functionality in severely injured patients and whether a relation with the development of infectious complications was present. RESULTS Fifteen severely injured patients (median ISS of 33) were included, of whom 6 developed an infection between day 4 and day 9 after trauma. The injury severity score did not significantly differ between patients who developed an infection and patients who did not (p = 0.529). Patients who developed an infection showed increased acidification immediately after trauma (p = 0.006) and after 3 days (p = 0.026) and a decrease in the days thereafter to levels in the lower normal range. In contrast, patients who did not develop infectious complications showed high-normal acidification within the first days and increased tasset to identify patients at risk for infections after trauma and to monitor the inflammatory state of these trauma patients. CONCLUSION Neutrophil function can be measured in the ICU setting by rapid point-of-care analysis of phagosomal acidification. This analysis differed between trauma patients who developed infectious complications and trauma patients who did not. Therefore, this assay might prove a valuable asset to identify patients at risk for infections after trauma and to monitor the inflammatory state of these trauma patients. TRIAL REGISTRATION Central Committee on Research Involving Human Subjects, NL43279.041.13. Registered 14 February 2014. https://www.toetsingonline.nl/to/ccmo_search.nsf/Searchform?OpenForm.
Collapse
Affiliation(s)
- Lillian Hesselink
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands.
- Center for Translational Immunology, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands.
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands.
| | - Roy Spijkerman
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
- Center for Translational Immunology, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
| | - Emma de Fraiture
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
- Center for Translational Immunology, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
| | - Suzanne Bongers
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
- Center for Translational Immunology, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
| | - Karlijn J P Van Wessem
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
| | - Nienke Vrisekoop
- Center for Translational Immunology, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
| | - Leo Koenderman
- Department of Respiratory Medicine, Wilhelmina Children's Hospital, Lundlaan 6, 3584, EA, Utrecht, the Netherlands
- Center for Translational Immunology, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
| | - Luke P H Leenen
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
| | - Falco Hietbrink
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands
| |
Collapse
|
9
|
Spijkerman R, Hesselink L, Hellebrekers P, Vrisekoop N, Hietbrink F, Leenen LPH, Koenderman L. Automated flow cytometry enables high performance point-of-care analysis of leukocyte phenotypes. J Immunol Methods 2019; 474:112646. [PMID: 31419409 DOI: 10.1016/j.jim.2019.112646] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 08/09/2019] [Accepted: 08/12/2019] [Indexed: 01/23/2023]
Abstract
INTRODUCTION Phagocytes such as granulocytes and monocytes are fundamental players in the innate immune system. Activation of these cells can be quantified by the measurement of activation marker expression using flow cytometry. Analysis of receptor expression on inflammatory cells facilitates the diagnosis of inflammatory diseases and can be used to determine the extent of inflammation. However, several major limitations of this analysis precludes application of inflammation monitoring in clinical practice. Fast and automated analysis would minimalize ex vivo manipulation and allow reproducible processing. The aim of this study was to evaluate a fully automated "load & go" flow cytometer for analyzing activation of granulocytes and monocytes in a clinically applicable setting. METHODS Blood samples were obtained from 10 anonymous and healthy volunteers between the age of 18 and 65 years. Granulocyte and monocyte activation was determined by the use of the markers CD35, CD11b and CD10 measured in the automated AQUIOS CL® "load & go" flow cytometer. This machine is able to pierce the tube caps, add antibodies, lyse and measure the sample within 20 min after vena puncture. Reproducibility tests were performed to test the stability of activation marker expression on phagocytes. The expression of activation markers was measured at different time points after blood drawing to analyze the effect of bench time on granulocyte and monocyte activation. RESULTS The duplicate experiments demonstrate a high reproducibility of the measurements of the activation state of phagocytes. Healthy controls showed a very homogenous expression of activation markers at T = 0 (immediately after vena puncture). Activation markers on neutrophils were already significantly increased after 1 h (T = 1) depicted as means (95%Cl) CD35: 2.2× (1.5×-2.5×) p = .028, CD11b: 2.5× (1.7×-3.1×) p = .023, CD10: 2.5× (2.1×-2.7×) p = .009) and a further increase in activation markers was observed after 2 and 3 h. Monocytes also showed a increase in activation markers in 1 h (mean (95%Cl) CD35: 1.8× (1.3×-2.2×) p = .058, CD11b: 2.13× (1.6×-2.4×) p = .025) and also a further significant increase in 2 and 3 h was observed. CONCLUSION This study showed that bench time of one hour already leads to a significant upregulation and bigger variance in activation markers of granulocytes and monocytes. In addition, it is likely that automated flow cytometry reduces intra-assay variability in the analysis of activation markers on inflammatory cells. Therefore, we found that it is of utmost importance to perform immune activation analysis as fast as possible to prevent drawing wrong conclusions. Automated flow cytometry is able to reduce this analysis from 2 h to only 15-20 min without the need of dedicated personnel and in a point-of-care context. This now allows fast and automated inflammation monitoring in blood samples obtained from a variety of patient groups. FUND: This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Collapse
Affiliation(s)
- Roy Spijkerman
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands; Laboratory of Translational Immunology (LTI) and Department of Respiratory Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands
| | - Lillian Hesselink
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands; Laboratory of Translational Immunology (LTI) and Department of Respiratory Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands.
| | - Pien Hellebrekers
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands; Laboratory of Translational Immunology (LTI) and Department of Respiratory Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands.
| | - Nienke Vrisekoop
- Laboratory of Translational Immunology (LTI) and Department of Respiratory Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands.
| | - Falco Hietbrink
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands.
| | - Luke P H Leenen
- Department of Trauma Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands.
| | - Leo Koenderman
- Laboratory of Translational Immunology (LTI) and Department of Respiratory Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands.
| |
Collapse
|
10
|
Hesselink L, Spijkerman R, van Wessem KJP, Koenderman L, Leenen LPH, Huber-Lang M, Hietbrink F. Neutrophil heterogeneity and its role in infectious complications after severe trauma. World J Emerg Surg 2019; 14:24. [PMID: 31164913 PMCID: PMC6542247 DOI: 10.1186/s13017-019-0244-3] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Accepted: 05/13/2019] [Indexed: 02/06/2023] Open
Abstract
Background Trauma leads to a complex inflammatory cascade that induces both immune activation and a refractory immune state in parallel. Although both components are deemed necessary for recovery, the balance is tight and easily lost. Losing the balance can lead to life-threatening infectious complications as well as long-term immunosuppression with recurrent infections. Neutrophils are known to play a key role in these processes. Therefore, this review focuses on neutrophil characteristics and function after trauma and how these features can be used to identify trauma patients at risk for infectious complications. Results Distinct neutrophil subtypes exist that play their own role in the recovery and/or development of infectious complications after trauma. Furthermore, the refractory immune state is related to the risk of infectious complications. These findings change the initial concepts of the immune response after trauma and give rise to new biomarkers for monitoring and predicting inflammatory complications in severely injured patients. Conclusion For early recognition of patients at risk, the immune system should be monitored. Several neutrophil biomarkers show promising results and analysis of these markers has become accessible to such extent that they can be used for point-of-care decision making after trauma.
Collapse
Affiliation(s)
- Lillian Hesselink
- Department of Trauma Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
- Laboratory of Translational Immunology and Department of Respiratory Medicine, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Roy Spijkerman
- Department of Trauma Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
- Laboratory of Translational Immunology and Department of Respiratory Medicine, University Medical Centre Utrecht, Utrecht, The Netherlands
| | | | - Leo Koenderman
- Laboratory of Translational Immunology and Department of Respiratory Medicine, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Luke P. H. Leenen
- Department of Trauma Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Markus Huber-Lang
- Institute of Clinical and Experimental Trauma Immunology, University Hospital of Ulm, Ulm, Germany
| | - Falco Hietbrink
- Department of Trauma Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
| |
Collapse
|