1
|
Tamizh Selvan G, Venkatachalam P. Potentials of cytokinesis blocked micronucleus assay in radiation triage and biological dosimetry. J Genet Eng Biotechnol 2024; 22:100409. [PMID: 39674629 PMCID: PMC11381789 DOI: 10.1016/j.jgeb.2024.100409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 02/04/2024] [Accepted: 08/06/2024] [Indexed: 09/11/2024]
Abstract
The measurement of micronucleus (MN) in the cytokinesis-block arrested binucleated cells has been extensively used as a biomarker in many radiation biology applications in specific biodosimetry. Following radiation casualties, medical management of exposed individuals begins with triage and biological dosimetry. The cytokinesis blocked micronucleus (CBMN) assay is the alternate for the gold standard dicentric chromosome assay in radiation dose assessment. In recent years, the CBMN assay has become well-validated and emerged as a method of choice for evaluating occupational and accidental exposures scenario. It is feasible due to its cost-effective, simple, and rapid dose assessment rather than a conventional chromosome aberration assay. PubMed search tool was used with keywords of MN, biodosimetry, radiotherapy and restricted to human samples. Since Fenech and Morely developed the assay, it has undergone many technical and technological reforms as a biomarker of various applications. In this review, we have abridged recent developments of the CBMN assay in radiation triage and biodosimetry, focusing on (a) the influence of variables on dose estimation, (b) the importance of baseline frequency and reported dose-response coefficient values among different laboratories, (c) inter-laboratory comparison and (d) its limitations and means to overcome them.
Collapse
Affiliation(s)
- G Tamizh Selvan
- Central Research Laboratory, K.S. Hegde Medical Academy, NITTE (Deemed to be University), Deralakatte, Mangalore, Karnataka, India.
| | - P Venkatachalam
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (Deemed to be University), Chennai, India
| |
Collapse
|
2
|
Wang Q, Bacon BA, Taveras M, Phillippi MA, Wu X, Broustas CG, Shuryak I, Turner HC. Biomarkers for Radiation Biodosimetry and Correlation with Hematopoietic Injury in a Humanized Mouse Model. Radiat Res 2024; 202:541-551. [PMID: 39034036 DOI: 10.1667/rade-24-00049.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Accepted: 05/25/2024] [Indexed: 07/23/2024]
Abstract
After a large-scale radiological or nuclear event, hundreds of thousands of people may be exposed to ionizing radiation and require subsequent medical management. Acute exposure to moderate doses (2-6 Gy) of radiation can lead to the hematopoietic acute radiation syndrome, in which the bone marrow (BM) is severely compromised, and severe hemorrhage and infection are common. Previously, we have developed a panel of intracellular protein markers (FDXR, ACTN1, DDB2, BAX, p53 and TSPYL2), designed to reconstruct absorbed radiation dose from human peripheral blood (PB) leukocyte samples in humanized mice up to 3 days after exposure. The objective of this work was to continue to use the humanized mouse model to evaluate biomarker dose-/time- kinetics in human PB leukocytes in vivo, at an earlier (day 2) and later (day 7) time point, after exposure to total-body irradiation (TBI) doses of 0 to 2 Gy of X rays. In addition, to assess hematological sensitivity and radiation-induced injury, PB leukocyte cell counts, human BM hematopoietic stem cell (HSC) and progenitor cell [multipotent progenitor (MPP), common myeloid progenitor (CMP), granulocyte myeloid progenitor (GMP), megakaryocyte/erythrocyte progenitor (MEP) and multi-lymphoid progenitor (MLP)] levels were measured, and their correlation was also examined as the BM damages are difficult to assess by routine tests. Peripheral blood B-cells were significantly lower after TBI doses of 0.5 Gy on day 2 and 2 Gy on days 2 and 7; T-cells were significantly reduced only on day 2 after 2 Gy TBI. Bone marrow HSCs and MPP cells showed a dose-dependent depletion after irradiation with 0.5 Gy and 2 Gy on day 2, and after 1 Gy and 2 Gy on day 7. Circulating B cells correlated with HSCs, MPP and MLP cells on day 2, whereas T cells correlated with MPP, and myeloid cells correlated with MLP cells. On day 7, B cells correlated with MPP, CMP, GMP and MEP, while myeloid cells correlated with CMP, GMP and MEP. The intracellular leukocyte biomarkers were able to discriminate unirradiated and irradiated samples at different time points calculated by receiver operating characteristic (ROC) curve. Using machine learning algorithm methods, combining ACTN1, p53, TSPYL2 and PB-T cell and PB-B cell counts served as a strong predictor (area under the ROC >0.8) to distinguish unirradiated and irradiated samples independent of the days after TBI. The results further validated our biomarker-based triage assay and additionally evaluated the radiation sensitivity of the hematopoietic system after TBI exposures.
Collapse
Affiliation(s)
- Qi Wang
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Bezalel A Bacon
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Maria Taveras
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Michelle A Phillippi
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Xuefeng Wu
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Constantinos G Broustas
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Helen C Turner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| |
Collapse
|
3
|
Harte DSG, Lynch AM, Verma J, Rees P, Filby A, Wills JW, Johnson GE. A multi-biomarker micronucleus assay using imaging flow cytometry. Arch Toxicol 2024; 98:3137-3153. [PMID: 38995349 PMCID: PMC11324684 DOI: 10.1007/s00204-024-03801-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 05/23/2024] [Indexed: 07/13/2024]
Abstract
Genetic toxicity testing assesses the potential of compounds to cause DNA damage. There are many genetic toxicology screening assays designed to assess the DNA damaging potential of chemicals in early drug development aiding the identification of promising drugs that have low-risk potential for causing genetic damage contributing to cancer risk in humans. Despite this, in vitro tests generate a high number of misleading positives, the consequences of which can lead to unnecessary animal testing and/or the abandonment of promising drug candidates. Understanding chemical Mode of Action (MoA) is vital to identifying the true genotoxic potential of substances and, therefore, the risk translation into the clinic. Here we demonstrate a simple, robust protocol for staining fixed, human-lymphoblast p53 proficient TK6 cells with antibodies against ɣH2AX, p53 and pH3S28 along with DRAQ5™ DNA staining that enables analysis of un-lysed cells via microscopy approaches such as imaging flow cytometry. Here, we used the Cytek® Amnis® ImageStream®X Mk II which provides a high-throughput acquisition platform with the sensitivity of flow cytometry and spatial morphological information associated with microscopy. Using the ImageStream manufacturer's software (IDEAS® 6.2), a masking strategy was developed to automatically detect and quantify micronucleus events (MN) and characterise biomarker populations. The gating strategy developed enables the generation of a template capable of automatically batch processing data files quantifying cell-cycle, MN, ɣH2AX, p53 and pH3 populations simultaneously. In this way, we demonstrate how a multiplex system enables DNA damage assessment alongside MN identification using un-lysed cells on the imaging flow cytometry platform. As a proof-of-concept, we use the tool chemicals carbendazim and methyl methanesulphonate (MMS) to demonstrate the assay's ability to correctly identify clastogenic or aneugenic MoAs using the biomarker profiles established.
Collapse
Affiliation(s)
- Danielle S G Harte
- Swansea University Medical School, Swansea University, Swansea, UK
- GSK R&D, Stevenage, UK
| | - Anthony M Lynch
- Swansea University Medical School, Swansea University, Swansea, UK
- GSK R&D, Stevenage, UK
| | - Jatin Verma
- Swansea University Medical School, Swansea University, Swansea, UK
| | - Paul Rees
- College of Engineering, Swansea University, Swansea, UK
- Imaging Platform, Broad Institute of MIT and Harvard, Cambridge, MA, USA
| | - Andrew Filby
- Core Flow Facility, Faculty of Medical Sciences, Newcastle University, Newcastle Upon Tyne, UK
| | - John W Wills
- GSK R&D, Stevenage, UK
- Department of Veterinary Medicine, Cambridge University, Cambridge, UK
| | - George E Johnson
- Swansea University Medical School, Swansea University, Swansea, UK.
| |
Collapse
|
4
|
Blakely WF, Port M, Ostheim P, Abend M. Radiation Research Society Journal-based Historical Review of the Use of Biomarkers for Radiation Dose and Injury Assessment: Acute Health Effects Predictions. Radiat Res 2024; 202:185-204. [PMID: 38936821 DOI: 10.1667/rade-24-00121.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 06/11/2024] [Indexed: 06/29/2024]
Abstract
A multiple-parameter based approach using radiation-induced clinical signs and symptoms, hematology changes, cytogenetic chromosomal aberrations, and molecular biomarkers changes after radiation exposure is used for biodosimetry-based dose assessment. In the current article, relevant milestones from Radiation Research are documented that forms the basis of the current consensus approach for diagnostics after radiation exposure. For example, in 1962 the use of cytogenetic chromosomal aberration using the lymphocyte metaphase spread dicentric assay for biodosimetry applications was first published in Radiation Research. This assay is now complimented using other cytogenetic chromosomal aberration assays (i.e., chromosomal translocations, cytokinesis-blocked micronuclei, premature chromosome condensation, γ-H2AX foci, etc.). Changes in blood cell counts represent an early-phase biomarker for radiation exposures. Molecular biomarker changes have evolved to include panels of organ-specific plasma proteomic and blood-based gene expression biomarkers for radiation dose assessment. Maturation of these assays are shown by efforts for automated processing and scoring, development of point-of-care diagnostics devices, service laboratories inter-comparison exercises, and applications for dose and injury assessments in radiation accidents. An alternative and complementary approach has been advocated with the focus to de-emphasize "dose" and instead focus on predicting acute or delayed health effects. The same biomarkers used for dose estimation (e.g., lymphocyte counts) can be used to directly predict the later developing severity degree of acute health effects without performing dose estimation as an additional or intermediate step. This review illustrates contributing steps toward these developments published in Radiation Research.
Collapse
Affiliation(s)
- William F Blakely
- Scientific Research Department, Armed Forces Radiobiology Research Institute, Uniformed Services University of the Health Sciences, Bethesda, Maryland
| | - Matthias Port
- Bundeswehr Institute of Radiobiology, Munich, Germany
| | | | - Michael Abend
- Bundeswehr Institute of Radiobiology, Munich, Germany
| |
Collapse
|
5
|
Beaton-Green LA, Mayenburg JM, Marro L, Sanchez SC, Lachapelle S, Wilkins RC. Multiparameter imaging flow cytometry-based cytokinesis-block micronucleus assay: Reduction of culture time and blood volume for improved efficiency. MUTATION RESEARCH. GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS 2024; 898:503792. [PMID: 39147444 PMCID: PMC11370997 DOI: 10.1016/j.mrgentox.2024.503792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 06/21/2024] [Accepted: 07/04/2024] [Indexed: 08/17/2024]
Abstract
In the event of a large-scale incident involving radiological or nuclear exposures, there is a potential for large numbers of individuals to have received doses of radiation sufficient to cause adverse health effects. It is imperative to quickly identify these individuals in order to provide information to the medical community to assist in making decisions about their treatment. The cytokinesis-block micronucleus assay is a well-established method for performing biodosimetry. This assay has previously been adapted to imaging flow cytometry and has been validated as a high-throughput option for providing dose estimates in the range of 0-10 Gy. The goal of this study was to test the ability to further optimize the assay by reducing the time of culture to 48 h from 68 h as well as reducing the volume of blood required for the analysis to 200 μL from 2 mL. These modifications would provide efficiencies in time and ease of processing impacting the ability to manage large numbers of samples and provide dose estimates in a timely manner. Results demonstrated that either the blood volume or the culture time could be reduced while maintaining dose estimates with sufficient accuracy for triage analysis. Reducing both the blood volume and culture time, however, resulted in poor dose estimates. In conclusion, depending on the needs of the scenario, either culture time or the blood volume could be reduced to improve the efficiency of analysis for mass casualty scenarios.
Collapse
Affiliation(s)
- Lindsay A Beaton-Green
- Environmental and Radiation Health Sciences Directorate, Health Canada, 775 Brookfield Road, PL 6303B, Ottawa, ON K1A 1C1, Canada
| | - Jessica M Mayenburg
- Environmental and Radiation Health Sciences Directorate, Health Canada, 775 Brookfield Road, PL 6303B, Ottawa, ON K1A 1C1, Canada
| | - Leonora Marro
- Environmental and Radiation Health Sciences Directorate, Health Canada, 775 Brookfield Road, PL 6303B, Ottawa, ON K1A 1C1, Canada
| | - Sarita Cuadros Sanchez
- Environmental and Radiation Health Sciences Directorate, Health Canada, 775 Brookfield Road, PL 6303B, Ottawa, ON K1A 1C1, Canada; University of Ottawa, Ottawa Hospital Research Institute, 501 Smyth Road, Ottawa, ON K1H 8L6, Canada
| | - Sylvie Lachapelle
- Environmental and Radiation Health Sciences Directorate, Health Canada, 775 Brookfield Road, PL 6303B, Ottawa, ON K1A 1C1, Canada
| | - Ruth C Wilkins
- Environmental and Radiation Health Sciences Directorate, Health Canada, 775 Brookfield Road, PL 6303B, Ottawa, ON K1A 1C1, Canada.
| |
Collapse
|
6
|
Repin M, Garty G, Garippa RJ, Brenner DJ. RABiT-III: an Automated Micronucleus Assay at a Non-Specialized Biodosimetry Facility. Radiat Res 2024; 201:567-571. [PMID: 38514936 PMCID: PMC11310857 DOI: 10.1667/rade-23-00120.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 03/14/2024] [Indexed: 03/23/2024]
Abstract
Micronuclei, detected through the cytokinesis-block micronucleus assay, are valuable indicators of ionizing radiation exposure, especially in short-term lymphocyte cultures. The peripheral human blood lymphocyte assay is recognized as a prime candidate for automated biodosimetry. In a prior project at the Columbia University Center for Radiological Research, we automated this assay using the 96-well ANSI/SLAS microplate standard format and relied on established biotech robotic systems named Rapid Automated Biodosimetry Tool (RABiT). In this study, we present the application of a similar automated biotech setup at an external high-throughput facility (RABiT-III) to implement the same automated cytokinesis-block micronucleus assay. Specifically, we employed the Agilent BRAVO liquid-handling system and GE IN Cell Analyzer 6000 imaging system in conjunction with the PerkinElmer Columbus image data storage and analysis system. Notably, this analysis system features an embedded PhenoLOGIC machine learning module, simplifying the creation of cell classification algorithms for CBMN assay image analysis and enabling the generation of radiation dose-response curves. This investigation underscores the adaptability of the RABiT-II CBMN protocol to diverse RABiT-III biotech robotic platforms in non-specialized biodosimetry centers. Furthermore, it highlights the advantages of machine learning in rapidly developing algorithms crucial for the high-throughput automated analysis of RABiT-III images.
Collapse
Affiliation(s)
- Mikhail Repin
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York
| | - Guy Garty
- Radiological Research Accelerator Facility, Columbia University Irving Medical Center, Irvington, New York
| | - Ralph J. Garippa
- Gene Editing & Screening Core Laboratory, Memorial Sloan Kettering Cancer Center, New York, New York
| | - David J. Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York
| |
Collapse
|
7
|
Tian XL, Zhang TT, Cai TJ, Tian M, Liu QJ. Screening radiation-differentially expressed circular RNAs and establishing dose classification models in the human lymphoblastoid cell line AHH-1. Int J Radiat Biol 2024; 100:550-564. [PMID: 38252315 DOI: 10.1080/09553002.2024.2304850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 12/19/2023] [Indexed: 01/23/2024]
Abstract
PURPOSE In the event of a large-scale radiological accident, rapid and high-throughput biodosimetry is the most vital basis in medical resource allocation for the prompt treatment of victims. However, the current biodosimeter is yet to be rapid and high-throughput. Studies have shown that ionizing radiation modulates expressions of circular RNAs (circRNAs) in healthy human cell lines and tumor tissue. circRNA expressions can be quantified rapidly and high-throughput. However, whether circRNAs are suitable for early radiation dose classification remains unclear. METHODS We employed transcriptome sequencing and bioinformatics analysis to screen for radiation-differentially expressed circRNAs in the human lymphoblastoid cell line AHH-1 at 4 h following exposure to 0, 2, and 5 Gy 60Co γ-rays. The dose-response relationships between differentially expressed circRNA expressions and absorbed doses were investigated using real-time polymerase chain reaction and linear regression analysis at 4 h, 24 h, and 48 h post-exposure to 0, 2, 4, 6, and 8 Gy. Six distinct dose classification models of circRNA panels were established and validated by receiver operating characteristic (ROC) curve analysis. RESULTS A total of 11 radiation-differentially expressed circRNAs were identified and validated. Based on dose-response effects, those circRNAs changed in a dose-responsive or dose-dependent manner were combined into panels A through F at 4 h, 24 h, and 48 h post-irradiation. ROC curve analysis showed that panels A through C had the potential to effectively classify exposed and non-exposed conditions, which area under the curve (AUC) of these three panels were all 1.000, and the associate p values were .009. Panels D through F excellently distinguished between different dose groups (AUC = 0.963-1.000, p < .05). The validation assay showed that panels A through F demonstrated consistent excellence in sensitivity and specificity in dose classification. CONCLUSIONS Ionizing radiation can indeed modulate the circRNA expression profile in the human lymphoblastoid cell line AHH-1. The differentially expressed circRNAs exhibit the potential for rapid and high-throughput dose classification.
Collapse
Affiliation(s)
- Xue-Lei Tian
- Chinese Center for Disease Control and Prevention, China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Beijing, PR China
| | - Ting-Ting Zhang
- Chinese Center for Disease Control and Prevention, China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Beijing, PR China
| | - Tian-Jing Cai
- Chinese Center for Disease Control and Prevention, China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Beijing, PR China
| | - Mei Tian
- Chinese Center for Disease Control and Prevention, China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Beijing, PR China
| | - Qing-Jie Liu
- Chinese Center for Disease Control and Prevention, China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Beijing, PR China
| |
Collapse
|
8
|
Satyamitra MM, Cassatt DR, Molinar-Inglis O, Rios CI, Taliaferro LP, Winters TA, DiCarlo AL. The NIAID/RNCP Biodosimetry Program: An Overview. Cytogenet Genome Res 2023; 163:89-102. [PMID: 37742625 PMCID: PMC10946631 DOI: 10.1159/000534213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Accepted: 09/18/2023] [Indexed: 09/26/2023] Open
Abstract
Established in 2004, the Radiation and Nuclear Countermeasures Program (RNCP), within the National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health has the central mission to advance medical countermeasure mitigators/therapeutics, and biomarkers and technologies to assess, triage, and inform medical management of patients experiencing acute radiation syndrome and/or the delayed effects of acute radiation exposure. The RNCP biodosimetry mission space encompasses: (1) basic research to elucidate novel approaches for rapid and accurate assessment of radiation exposure, (2) studies to support advanced development for US Food and Drug Administration (FDA) clearance of promising triage or treatment devices/approaches, (3) characterization of biomarkers and/or assays to determine degree of tissue or organ dose that can predict outcome of radiation injuries (i.e., organ failure, morbidity, and/or mortality), and (4) outreach efforts to facilitate interactions with researchers developing cutting edge biodosimetry approaches. Thus far, no biodosimetry device has been FDA cleared for use during a radiological/nuclear incident. At NIAID, advancement of radiation biomarkers and biodosimetry approaches is facilitated by a variety of funding mechanisms (grants, contracts, cooperative and interagency agreements, and Small Business Innovation Research awards), with the objective of advancing devices and assays toward clearance, as outlined in the FDA's Radiation Biodosimetry Medical Countermeasure Devices Guidance. The ultimate goal of the RNCP biodosimetry program is to develop and establish accurate and reliable biodosimetry tools that will improve radiation preparedness and ultimately save lives during a radiological or nuclear incident.
Collapse
Affiliation(s)
- Merriline M Satyamitra
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology, and Transplantation (DAIT), U.S. Department of Health and Human Services (HHS), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, Maryland, USA
| | - David R Cassatt
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology, and Transplantation (DAIT), U.S. Department of Health and Human Services (HHS), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, Maryland, USA
| | - Olivia Molinar-Inglis
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology, and Transplantation (DAIT), U.S. Department of Health and Human Services (HHS), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, Maryland, USA
| | - Carmen I Rios
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology, and Transplantation (DAIT), U.S. Department of Health and Human Services (HHS), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, Maryland, USA
| | - Lanyn P Taliaferro
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology, and Transplantation (DAIT), U.S. Department of Health and Human Services (HHS), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, Maryland, USA
| | - Thomas A Winters
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology, and Transplantation (DAIT), U.S. Department of Health and Human Services (HHS), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, Maryland, USA
| | - Andrea L DiCarlo
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology, and Transplantation (DAIT), U.S. Department of Health and Human Services (HHS), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), Rockville, Maryland, USA
| |
Collapse
|
9
|
Wilkins RC, Beaton-Green LA. Development of high-throughput systems for biodosimetry. RADIATION PROTECTION DOSIMETRY 2023; 199:1477-1484. [PMID: 37721060 PMCID: PMC10720693 DOI: 10.1093/rpd/ncad060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 01/24/2023] [Accepted: 02/08/2023] [Indexed: 09/19/2023]
Abstract
Biomarkers for ionising radiation exposure have great utility in scenarios where there has been a potential exposure and physical dosimetry is missing or in dispute, such as for occupational and accidental exposures. Biomarkers that respond as a function of dose are particularly useful as biodosemeters to determine the dose of radiation to which an individual has been exposed. These dose measurements can also be used in medical scenarios to track doses from medical exposures and even have the potential to identify an individual's response to radiation exposure that could help tailor treatments. The measurement of biomarkers of exposure in medicine and for accidents, where a larger number of samples would be required, is limited by the throughput of analysis (i.e. the number of samples that could be processed and analysed), particularly for microscope-based methods, which tend to be labour-intensive. Rapid analysis in an emergency scenario, such as a large-scale accident, would provide dose estimates to medical practitioners, allowing timely administration of the appropriate medical countermeasures to help mitigate the effects of radiation exposure. In order to improve sample throughput for biomarker analysis, much effort has been devoted to automating the process from sample preparation through automated image analysis. This paper will focus mainly on biological endpoints traditionally analysed by microscopy, specifically dicentric chromosomes, micronuclei and gamma-H2AX. These endpoints provide examples where sample throughput has been improved through automated image acquisition, analysis of images acquired by microscopy, as well as methods that have been developed for analysis using imaging flow cytometry.
Collapse
Affiliation(s)
- Ruth C Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| | - Lindsay A Beaton-Green
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| |
Collapse
|
10
|
Beaton-Green LA, Mayenburg JM, Marro L, Hassan EM, Cuadros Sanchez S, Darwish R, Lachapelle S, Adam N, Burtt JJ, Van Den Hanenberg C, Rodrigues MA, Wang Q, Brenner DJ, Turner HC, Wilkins RC. Application of the Cytokinesis-Block Micronucleus Assay for High-Dose Exposures Using Imaging Flow Cytometry. Cytogenet Genome Res 2023; 163:131-142. [PMID: 37527635 DOI: 10.1159/000532124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 07/20/2023] [Indexed: 08/03/2023] Open
Abstract
The cytokinesis-block micronucleus assay is a well-established method to assess radiation-induced genetic damage in human cells. This assay has been adapted to imaging flow cytometry (IFC), allowing automated analysis of many cells, and eliminating the need to create microscope slides. Furthermore, to improve the efficiency of assay performance, a small-volume method previously developed was employed. Irradiated human blood samples were cultured, stained, and analyzed by IFC to produce images of the cells. Samples were run using both manual and 96-well plate automated acquisition. Multiple parameter-based image features were collected for each sample, and the results were compared to confirm that these acquisition methods are functionally identical. This paper details the multi-parametric analysis developed and the resulting calibration curves up to 10 Gy. The calibration curves were created using a quadratic random coefficient model with Poisson errors, as well as a logistic discriminant function. The curves were then validated with blinded, irradiated samples, using relative bias and relative mean square error. Overall, the accuracy of the dose estimates was adequate for triage dosimetry (within 1 Gy of the true dose) over 90% of the time for lower doses and about half the time for higher doses, with the lowest success rate between 5 and 6 Gy where the calibration curve reached its peak and there was the smallest change in MN/BNC with dose. This work describes the application of a novel multi-parametric analysis that fits the calibration curves and allows dose estimates up to 10 Gy, which were previously limited to 4 Gy. Furthermore, it demonstrates that the results from samples acquired manually and with the autosampler are functionally similar.
Collapse
Affiliation(s)
- Lindsay A Beaton-Green
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Jessica M Mayenburg
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Leonora Marro
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Eman M Hassan
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Sarita Cuadros Sanchez
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Riham Darwish
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Sylvie Lachapelle
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Nadine Adam
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Julie J Burtt
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Cyndi Van Den Hanenberg
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | | | - Qi Wang
- Center for Radiological Research, Columbia University Medical Center, New York, New York, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Medical Center, New York, New York, USA
| | - Helen C Turner
- Center for Radiological Research, Columbia University Medical Center, New York, New York, USA
| | - Ruth C Wilkins
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| |
Collapse
|
11
|
Vijayalakshmi J, Chaurasia RK, Srinivas KS, Vijayalakshmi K, Paul SF, Bhat N, Sapra B. Establishment of ex vivo calibration curve for X-ray induced "dicentric + ring" and micronuclei in human peripheral lymphocytes for biodosimetry during radiological emergencies, and validation with dose blinded samples. Heliyon 2023; 9:e17068. [PMID: 37484390 PMCID: PMC10361230 DOI: 10.1016/j.heliyon.2023.e17068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 05/31/2023] [Accepted: 06/06/2023] [Indexed: 07/25/2023] Open
Abstract
In the modern developing society, application of radiation has increased extensively. With significant improvement in the radiation protection practices, exposure to human could be minimized substantially, but cannot be avoided completely. Assessment of exposure is essential for regulatory decision and medical management as applicable. Until now, cytogenetic changes have served as surrogate marker of radiation exposure and have been extensively employed for biological dose estimation of various planned and unplanned exposures. Dicentric Chromosomal Aberration (DCA) is radiation specific and is considered as gold standard, micronucleus is not very specific to radiation and is considered as an alternative method for biodosimetry. In this study dose response curves were generated for X-ray induced "dicentric + ring" and micronuclei, in lymphocytes of three healthy volunteers [2 females (age 22, 23 years) and 1 male (24 year)]. The blood samples were irradiated with X-ray using LINAC (energy 6 MV, dose rate 6 Gy/min), in the dose range of 0-5Gy. Irradiated blood samples were cultured and processed to harvest metaphases, as per standard procedures recommended by International Atomic Energy Agency. Pooled data obtained from all the three volunteers, were in agreement with Poisson distribution for "dicentric + ring", however over dispersion was observed for micronuclei. Data ("dicentric + ring" and micronuclei) were fitted by linear quadratic model of the expression Y[bond, double bond]C + αD + βD2 using Dose Estimate software, version 5.2. The data fit has resulted in linear coefficient α = 0.0006 (±0.0068) "dicentric + ring" cell-1 Gy-1 and quadratic coefficient β = 0.0619 (±0.0043) "dicentric + ring" cell-1 Gy-2 for "dicentric + ring" and linear coefficient α = 0.0459 ± (0.0038) micronuclei cell-1 Gy-1 and quadratic coefficient β = 0.0185 ± (0.0010) micronuclei cell-1 Gy-2 for micronuclei, respectively. Background frequencies for "dicentric + ring" and micronuclei were 0.0006 ± 0.0004 and 0.0077 ± 0.0012 cell-1, respectively. Established curves were validated, by reconstructing the doses of 8 dose blinded samples (4 by DCA and 4 by CBMN) using coefficients generated here. Estimated doses were within the variation of 0.9-16% for "dicentric + ring" and 21.7-31.2% for micronuclei respectively. These established curves have potential to be employed for biodosimetry of occupational, clinical and accidental exposures, for initial triage and medical management.
Collapse
Affiliation(s)
- J. Vijayalakshmi
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (DU), Chennai, India
| | - Rajesh Kumar Chaurasia
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
- Homi Bhabha National Institute (HBNI), Mumbai, India
| | - K. Satish Srinivas
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (DU), Chennai, India
| | - K. Vijayalakshmi
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (DU), Chennai, India
| | - Solomon F.D. Paul
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (DU), Chennai, India
| | - N.N. Bhat
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
- Homi Bhabha National Institute (HBNI), Mumbai, India
| | - B.K. Sapra
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), Mumbai, India
- Homi Bhabha National Institute (HBNI), Mumbai, India
| |
Collapse
|
12
|
M’Kacher R, Colicchio B, Junker S, El Maalouf E, Heidingsfelder L, Plesch A, Dieterlen A, Jeandidier E, Carde P, Voisin P. High Resolution and Automatable Cytogenetic Biodosimetry Using In Situ Telomere and Centromere Hybridization for the Accurate Detection of DNA Damage: An Overview. Int J Mol Sci 2023; 24:ijms24065699. [PMID: 36982772 PMCID: PMC10054499 DOI: 10.3390/ijms24065699] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 03/07/2023] [Accepted: 03/10/2023] [Indexed: 03/19/2023] Open
Abstract
In the event of a radiological or nuclear accident, or when physical dosimetry is not available, the scoring of radiation-induced chromosomal aberrations in lymphocytes constitutes an essential tool for the estimation of the absorbed dose of the exposed individual and for effective triage. Cytogenetic biodosimetry employs different cytogenetic assays including the scoring of dicentrics, micronuclei, and translocations as well as analyses of induced premature chromosome condensation to define the frequency of chromosome aberrations. However, inherent challenges using these techniques include the considerable time span from sampling to result, the sensitivity and specificity of the various techniques, and the requirement of highly skilled personnel. Thus, techniques that obviate these challenges are needed. The introduction of telomere and centromere (TC) staining have successfully met these challenges and, in addition, greatly improved the efficiency of cytogenetic biodosimetry through the development of automated approaches, thus reducing the need for specialized personnel. Here, we review the role of the various cytogenetic dosimeters and their recent improvements in the management of populations exposed to genotoxic agents such as ionizing radiation. Finally, we discuss the emerging potentials to exploit these techniques in a wider spectrum of medical and biological applications, e.g., in cancer biology to identify prognostic biomarkers for the optimal triage and treatment of patients.
Collapse
Affiliation(s)
- Radhia M’Kacher
- Cell Environment DNA Damage R&D, Genopole, 91000 Evry-Courcouronnes, France
- Correspondence: ; Tel.: +33-160878918
| | - Bruno Colicchio
- IRIMAS, Institut de Recherche en Informatique, Mathématiques, Automatique et Signal, Université de Haute-Alsace, 69093 Mulhouse, France
| | - Steffen Junker
- Institute of Biomedicine, University of Aarhus, DK-8000 Aarhus, Denmark
| | - Elie El Maalouf
- Cell Environment DNA Damage R&D, Genopole, 91000 Evry-Courcouronnes, France
| | | | - Andreas Plesch
- MetaSystems GmbH, Robert-Bosch-Str. 6, D-68804 Altlussheim, Germany
| | - Alain Dieterlen
- IRIMAS, Institut de Recherche en Informatique, Mathématiques, Automatique et Signal, Université de Haute-Alsace, 69093 Mulhouse, France
| | - Eric Jeandidier
- Laboratoire de Génétique, Groupe Hospitalier de la Région de Mulhouse Sud-Alsace, 69093 Mulhouse, France
| | - Patrice Carde
- Department of Hematology, Institut Gustave Roussy, 94804 Villejuif, France
| | - Philippe Voisin
- Cell Environment DNA Damage R&D, Genopole, 91000 Evry-Courcouronnes, France
| |
Collapse
|
13
|
Wilkins RC, Rodrigues M, Beaton-Green LA. The Imaging Flow Cytometry-Based Cytokinesis-Block MicroNucleus (CBMN) Assay. Methods Mol Biol 2023; 2635:103-122. [PMID: 37074659 DOI: 10.1007/978-1-0716-3020-4_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2023]
Abstract
The dose of ionizing radiation received by an individual can be determined using biodosimetry methods which measure biomarkers of exposure in tissue samples from that individual. These markers can be expressed in many ways, including DNA damage and repair processes. Following a mass casualty event involving radiological or nuclear material, it is important to rapidly provide this information to medical responders to assist in the medical management of potentially exposed casualties. Traditional methods of biodosimetry rely on microscope analysis, making them time-consuming and labor-intensive. To increase sample throughput following a large-scale radiological mass casualty event, several biodosimetry assays have been adapted for analysis by imaging flow cytometry. This chapter briefly reviews these methods with a focus on the most current methodology to identify and quantify micronuclei in binucleated cells within the cytokinesis-block micronucleus assay using an imaging flow cytometer.
Collapse
Affiliation(s)
- Ruth C Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, ON, Canada.
| | | | | |
Collapse
|
14
|
Shuryak I, Royba E, Repin M, Turner HC, Garty G, Deoli N, Brenner DJ. A machine learning method for improving the accuracy of radiation biodosimetry by combining data from the dicentric chromosomes and micronucleus assays. Sci Rep 2022; 12:21077. [PMID: 36473912 PMCID: PMC9726929 DOI: 10.1038/s41598-022-25453-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Accepted: 11/30/2022] [Indexed: 12/12/2022] Open
Abstract
A large-scale malicious or accidental radiological event can expose vast numbers of people to ionizing radiation. The dicentric chromosome (DCA) and cytokinesis-block micronucleus (CBMN) assays are well-established biodosimetry methods for estimating individual absorbed doses after radiation exposure. Here we used machine learning (ML) to test the hypothesis that combining automated DCA and CBMN assays will improve dose reconstruction accuracy, compared with using either cytogenetic assay alone. We analyzed 1349 blood sample aliquots from 155 donors of different ages (3-69 years) and sexes (49.1% males), ex vivo irradiated with 0-8 Gy at dose rates from 0.08 Gy/day to ≥ 600 Gy/s. We compared the performances of several state-of-the-art ensemble ML methods and found that random forest generated the best results, with R2 for actual vs. reconstructed doses on a testing data subset = 0.845, and mean absolute error = 0.628 Gy. The most important predictor variables were CBMN and DCA frequencies, and age. Removing CBMN or DCA data from the model significantly increased squared errors on testing data (p-values 3.4 × 10-8 and 1.1 × 10-6, respectively). These findings demonstrate the promising potential of combining CBMN and DCA assay data to reconstruct radiation doses in realistic scenarios of heterogeneous populations exposed to a mass-casualty radiological event.
Collapse
Affiliation(s)
- Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th Street, VC-11-234/5, New York, NY, 10032, USA.
| | - Ekaterina Royba
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th Street, VC-11-234/5, New York, NY, 10032, USA
| | - Mikhail Repin
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th Street, VC-11-234/5, New York, NY, 10032, USA
| | - Helen C Turner
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th Street, VC-11-234/5, New York, NY, 10032, USA
| | - Guy Garty
- Radiological Research Accelerator Facility, Columbia University Irving Medical Center, Irvington, NY, USA
| | - Naresh Deoli
- Radiological Research Accelerator Facility, Columbia University Irving Medical Center, Irvington, NY, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th Street, VC-11-234/5, New York, NY, 10032, USA
| |
Collapse
|
15
|
Liu G. Revision of cytogenetic dosimetry in the IAEA manual 2011 based on data about radio-sensitivity and dose-rate findings contributing. FASEB J 2022; 36:e22621. [PMID: 36260291 DOI: 10.1096/fj.202200769rr] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 08/31/2022] [Accepted: 10/10/2022] [Indexed: 11/11/2022]
Abstract
In order to achieve the goal of rapid response, effective controland protection of life inlarge-scale radiation events, the IAEA Manual 2011 has been revised based on the data of radio-sensitivity, dose-rate findings. Analyze individual differences in radiation sensitivity using 60 Co radiation (0.27 Gy/min). Chromosomal aberrations with different irradiation dose rates were used to establish the biological dose curve and analyze the excess of the "dicentric + ring" caused by the dose rate at each dose point; DAPI-images and Metafer 4 were used to capture metaphase images and make further analysis. The data were collected in 2020, Dicentric + ring/100 Cells was 17.5-43.8, the average value was28.32 ± 6.98. The mean value of Dicentric + ring/100 Cells was 31.37 in males while 25.27 in females, there are significant differences (p < .01). The irradiation dose is dominant, At each dose point, the value of"(dicentric chromosome + centric rings)/cell" is proportional to "dose rate", that is, Y = kx + b, within the dose range of 1-5 Gy, "(dicentric chromosome + centric rings)/Cell" holds a quadratic linear relationship with dose rate, that is, y = ax2 + bx + c; The DAPI-images might give you more hints than those of conventional Giemsa-stain. The authors recommend that the IAEA Manual 2011 could be revised based on data of radio-sensitivity and dose-rate, which may contribute to the establishment of a unified dose-response calibration curve and stimulation of potential for automation in cytogenetic biodosimetry. (1) Individual differences of radiosensitivity are very large. (2) At each dose point, "(dicentric chromosome + centric rings)/cell" is proportional to "dose rate", that is, Y = kx + b. (3) "(dicentric chromosome + centric rings)/Cell" is a quadratic linear relationship with dose rate, that is, y = ax2 + bx + c. (4) We created a "Unity Standard Curve of Biological Dose Estimation". Creating a Unity Standard Curve of Biological Dose, under these circumstances, we can form a joint and rapid response to a nuclear and radiological accident.
Collapse
Affiliation(s)
- Gang Liu
- Gansu Provincial Center for Disease Control and Prevention, Joint Laboratory of Institute of Radiology, Chinese Academy of Medical Sciences, Lanzhou, China
| |
Collapse
|
16
|
Cyto-Genotoxicity of Tritiated Stainless Steel and Cement Particles in Human Lung Cell Models. Int J Mol Sci 2022; 23:ijms231810398. [PMID: 36142309 PMCID: PMC9499181 DOI: 10.3390/ijms231810398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 08/11/2022] [Accepted: 08/12/2022] [Indexed: 11/17/2022] Open
Abstract
During the decommissioning of nuclear facilities, the tritiated materials must be removed. These operations generate tritiated steel and cement particles that could be accidentally inhaled by workers. Thus, the consequences of human exposure by inhalation to these particles in terms of radiotoxicology were investigated. Their cyto-genotoxicity was studied using two human lung models: the BEAS-2B cell line and the 3D MucilAirTM model. Exposures of the BEAS-2B cell line to particles (2 and 24 h) did not induce significant cytotoxicity. Nevertheless, DNA damage occurred upon exposure to tritiated and non-tritiated particles, as observed by alkaline comet assay. Tritiated particles only induced cytostasis; however, both induced a significant increase in centromere negative micronuclei. Particles were also assessed for their effects on epithelial integrity and metabolic activity using the MucilAirTM model in a 14-day kinetic mode. No effect was noted. Tritium transfer through the epithelium was observed without intracellular accumulation. Overall, tritiated and non-tritiated stainless steel and cement particles were associated with moderate toxicity. However, these particles induce DNA lesions and chromosome breakage to which tritium seems to contribute. These data should help in a better management of the risk related to the inhalation of these types of particles.
Collapse
|
17
|
Shen X, Chen Y, Li C, Yang F, Wen Z, Zheng J, Zhou Z. Rapid and automatic detection of micronuclei in binucleated lymphocytes image. Sci Rep 2022; 12:3913. [PMID: 35273270 PMCID: PMC8913785 DOI: 10.1038/s41598-022-07936-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 02/28/2022] [Indexed: 11/09/2022] Open
Abstract
Cytokinesis block micronucleus (CBMN) assay is a widely used radiation biological dose estimation method. However, the subjectivity and the time-consuming nature of manual detection limits CBMN for rapid standard assay. The CBMN analysis is combined with a convolutional neural network to create a software for rapid standard automated detection of micronuclei in Giemsa stained binucleated lymphocytes images in this study. Cell acquisition, adhesive cell mass segmentation, cell type identification, and micronucleus counting are the four steps of the software's analysis workflow. Even when the cytoplasm is hazy, several micronuclei are joined to each other, or micronuclei are attached to the nucleus, this algorithm can swiftly and efficiently detect binucleated cells and micronuclei in a verification of 2000 images. In a test of 20 slides, the software reached a detection rate of 99.4% of manual detection in terms of binucleated cells, with a false positive rate of 14.7%. In terms of micronuclei detection, the software reached a detection rate of 115.1% of manual detection, with a 26.2% false positive rate. Each image analysis takes roughly 0.3 s, which is an order of magnitude faster than manual detection.
Collapse
Affiliation(s)
- Xiang Shen
- School of Mechanical Engineering and Automation, Beihang University, Beijing, 100083, China
| | - Ying Chen
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Chaowen Li
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Fucheng Yang
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Zhanbo Wen
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Jinlin Zheng
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Zhenggan Zhou
- School of Mechanical Engineering and Automation, Beihang University, Beijing, 100083, China.
| |
Collapse
|
18
|
Satyamitra M, Reyes Turcu FE, Pantoja-Galicia N, Wathen L. Challenges and Strategies in the Development of Radiation Biodosimetry Tests for Patient Management. Radiat Res 2021; 196:455-467. [PMID: 34143223 PMCID: PMC9923779 DOI: 10.1667/rade-21-00072.1] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 04/28/2021] [Indexed: 11/03/2022]
Abstract
The public health and medical response to a radiological or nuclear incident requires the capability to sort, assess, treat, triage and ultimately discharge, as well as to refer or transport people to their next step in medical care. The Public Health Emergency Medical Countermeasures Enterprise (PHEMCE), directed by the U.S. Department of Health and Human Services (HHS), facilitates a comprehensive, multi-agency effort to develop and deploy radiation biodosimetry tests. Within HHS, discovery and development of biodosimetry tests includes the National Institute of Allergy and Infectious Diseases (NIAID) National Institutes of Health (NIH), the Office of the Assistant Secretary of Preparedness and Response (ASPR), Biomedical Advanced Research and Development Authority (BARDA), and the Food and Drug Administration (FDA) as primary partners in this endeavor. The study of radiation biodosimetry has advanced significantly, with expansion into the fields of cytogenetics, genomics, proteomics, metabolomics, lipidomics and transcriptomics. In addition, expansion of traditional cytogenetic assessment methods using automated platforms, and development of laboratory surge capacity networks have helped to advance biodefense preparedness. This article describes various programs and coordinating efforts between NIAID, BARDA and FDA in the development of radiation biodosimetry approaches to respond to radiological and nuclear threats.
Collapse
Affiliation(s)
- Merriline Satyamitra
- Radiation and Nuclear Countermeasures Program (RNCP), Division of Allergy, Immunology, and Transplantation (DAIT), National Institute of Allergy and Infectious Diseases (NIAID), National Institutes of Health (NIH), U.S. Department of Health and Human Services (HHS), Rockville, Maryland 20892-9828
| | - Francisca E. Reyes Turcu
- United States Food and Drug Administration (U.S. FDA), Center for Devices and Radiological Health (CDRH), Silver Spring, Maryland 20993-0002
| | - Norberto Pantoja-Galicia
- United States Food and Drug Administration (U.S. FDA), Center for Devices and Radiological Health (CDRH), Silver Spring, Maryland 20993-0002
| | - Lynne Wathen
- Biomedical Advanced Research and Development Authority (BARDA), Office of the Assistant Secretary for Preparedness and Response (ASPR), U.S. Department of Health and Human Services (HHS), Washington, DC 20201
| |
Collapse
|
19
|
Capaccio C, Perrier JR, Cunha L, Mahnke RC, Lörch T, Porter M, Smith CL, Damer K, Bourland JD, Frizzell B, Torelli J, Vasquez M, Brower JB, Doyle-Eisele M, Taveras M, Turner H, Brenner DJ, Kowalski R. CytoRADx: A High-Throughput, Standardized Biodosimetry Diagnostic System Based on the Cytokinesis-Block Micronucleus Assay. Radiat Res 2021; 196:523-534. [PMID: 34515768 DOI: 10.1667/rade-20-00030.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2020] [Accepted: 08/26/2021] [Indexed: 11/03/2022]
Abstract
In a large-scale catastrophe, such as a nuclear detonation in a major city, it will be crucial to accurately diagnose large numbers of people to direct scarce medical resources to those in greatest need. Currently no FDA-cleared tests are available to diagnose radiation exposures, which can lead to complex, life-threatening injuries. To address this gap, we have achieved substantial advancements in radiation biodosimetry through refinement and adaptation of the cytokinesis-block micronucleus (CBMN) assay as a high throughput, quantitative diagnostic test. The classical CBMN approach, which quantifies micronuclei (MN) resulting from DNA damage, suffers from considerable time and expert labor requirements, in addition to a lack of universal methodology across laboratories. We have developed the CytoRADx™ System to address these drawbacks by implementing a standardized reagent kit, optimized assay protocol, fully automated microscopy and image analysis, and integrated dose prediction. These enhancements allow the CytoRADx System to obtain high-throughput, standardized results without specialized labor or laboratory-specific calibration curves. The CytoRADx System has been optimized for use with both humans and non-human primates (NHP) to quantify radiation dose-dependent formation of micronuclei in lymphocytes, observed using whole blood samples. Cell nuclei and resulting MN are fluorescently stained and preserved on durable microscope slides using materials provided in the kit. Up to 1,000 slides per day are subsequently scanned using the commercially based RADxScan™ Imager with customized software, which automatically quantifies the cellular features and calculates the radiation dose. Using less than 1 mL of blood, irradiated ex vivo, our system has demonstrated accurate and precise measurement of exposures from 0 to 8 Gy (90% of results within 1 Gy of delivered dose). These results were obtained from 636 human samples (24 distinct donors) and 445 NHP samples (30 distinct subjects). The system demonstrated comparable results during in vivo studies, including an investigation of 43 NHPs receiving single-dose total-body irradiation. System performance is repeatable across laboratories, operators, and instruments. Results are also statistically similar across diverse populations, considering various demographics, common medications, medical conditions, and acute injuries associated with radiological disasters. Dose calculations are stable over time as well, providing reproducible results for at least 28 days postirradiation, and for blood specimens collected and stored at room temperature for at least 72 h. The CytoRADx System provides significant advancements in the field of biodosimetry that will enable accurate diagnoses across diverse populations in large-scale emergency scenarios. In addition, our technological enhancements to the well-established CBMN assay provide a pathway for future diagnostic applications, such as toxicology and oncology.
Collapse
Affiliation(s)
| | - Jay R Perrier
- ASELL, LLC, Owings Mills, Maryland
- Columbia University, Center for Radiological Research, New York, New York
| | - Lídia Cunha
- Columbia University, Center for Radiological Research, New York, New York
| | | | | | | | | | | | - J Daniel Bourland
- Wake Forest School of Medicine, Departments of Radiation Oncology, Physics, and Biomedical Engineering, Winston-Salem, North Carolina
| | - Bart Frizzell
- Wake Forest School of Medicine, Departments of Radiation Oncology, Physics, and Biomedical Engineering, Winston-Salem, North Carolina
| | | | | | - Jeremy B Brower
- Lovelace Biomedical Research Institute, Albuquerque, New Mexico
| | | | - Maria Taveras
- Columbia University, Center for Radiological Research, New York, New York
| | - Helen Turner
- Columbia University, Center for Radiological Research, New York, New York
| | - David J Brenner
- Columbia University, Center for Radiological Research, New York, New York
| | | |
Collapse
|
20
|
Inter-laboratory automation of the in vitro micronucleus assay using imaging flow cytometry and deep learning. Arch Toxicol 2021; 95:3101-3115. [PMID: 34245348 PMCID: PMC8380241 DOI: 10.1007/s00204-021-03113-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Accepted: 06/29/2021] [Indexed: 12/31/2022]
Abstract
The in vitro micronucleus assay is a globally significant method for DNA damage quantification used for regulatory compound safety testing in addition to inter-individual monitoring of environmental, lifestyle and occupational factors. However, it relies on time-consuming and user-subjective manual scoring. Here we show that imaging flow cytometry and deep learning image classification represents a capable platform for automated, inter-laboratory operation. Images were captured for the cytokinesis-block micronucleus (CBMN) assay across three laboratories using methyl methanesulphonate (1.25-5.0 μg/mL) and/or carbendazim (0.8-1.6 μg/mL) exposures to TK6 cells. Human-scored image sets were assembled and used to train and test the classification abilities of the "DeepFlow" neural network in both intra- and inter-laboratory contexts. Harnessing image diversity across laboratories yielded a network able to score unseen data from an entirely new laboratory without any user configuration. Image classification accuracies of 98%, 95%, 82% and 85% were achieved for 'mononucleates', 'binucleates', 'mononucleates with MN' and 'binucleates with MN', respectively. Successful classifications of 'trinucleates' (90%) and 'tetranucleates' (88%) in addition to 'other or unscorable' phenotypes (96%) were also achieved. Attempts to classify extremely rare, tri- and tetranucleated cells with micronuclei into their own categories were less successful (≤ 57%). Benchmark dose analyses of human or automatically scored micronucleus frequency data yielded quantitation of the same equipotent concentration regardless of scoring method. We conclude that this automated approach offers significant potential to broaden the practical utility of the CBMN method across industry, research and clinical domains. We share our strategy using openly-accessible frameworks.
Collapse
|
21
|
Kirsch-Volders M, Fenech M. Inflammatory cytokine storms severity may be fueled by interactions of micronuclei and RNA viruses such as COVID-19 virus SARS-CoV-2. A hypothesis. MUTATION RESEARCH. REVIEWS IN MUTATION RESEARCH 2021; 788:108395. [PMID: 34893160 PMCID: PMC8479308 DOI: 10.1016/j.mrrev.2021.108395] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 09/23/2021] [Accepted: 09/23/2021] [Indexed: 12/25/2022]
Abstract
In this review we bring together evidence that (i) RNA viruses are a cause of chromosomal instability and micronuclei (MN), (ii) those individuals with high levels of lymphocyte MN have a weakened immune response and are more susceptible to RNA virus infection and (iii) both RNA virus infection and MN formation can induce inflammatory cytokine production. Based on these observations we propose a hypothesis that those who harbor elevated frequencies of MN within their cells are more prone to RNA virus infection and are more likely, through combined effects of leakage of self-DNA from MN and RNA from viruses, to escalate pro-inflammatory cytokine production via the cyclic GMP-AMP synthase (cGAS), stimulator of interferon genes (STING) and the Senescence Associated Secretory Phenotype (SASP) mechanisms to an extent that is unresolvable and therefore confers high risk of causing tissue damage by an excessive and overtly toxic immune response. The corollaries from this hypothesis are (i) those with abnormally high MN frequency are more prone to infection by RNA viruses; (ii) the extent of cytokine production and pro-inflammatory response to infection by RNA viruses is enhanced and possibly exceeds threshold levels that may be unresolvable in those with elevated MN levels in affected organs; (iii) reduction of MN frequency by improving nutrition and life-style factors increases resistance to RNA virus infection and moderates inflammatory cytokine production to a level that is immunologically efficacious and survivable.
Collapse
Affiliation(s)
- Micheline Kirsch-Volders
- Laboratory for Cell Genetics, Department Biology, Faculty of Sciences and Bio-engineering Sciences, Vrije Universiteit Brussel, Pleinlaan 2, 1050, Brussels, Belgium.
| | - Michael Fenech
- Genome Health Foundation, North Brighton, SA, 5048, Australia; Clinical and Health Sciences, University of South Australia, SA, 5000, Australia; Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia.
| |
Collapse
|
22
|
Rodrigues MA, Probst CE, Zayats A, Davidson B, Riedel M, Li Y, Venkatachalam V. The in vitro micronucleus assay using imaging flow cytometry and deep learning. NPJ Syst Biol Appl 2021; 7:20. [PMID: 34006858 PMCID: PMC8131758 DOI: 10.1038/s41540-021-00179-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Accepted: 02/16/2021] [Indexed: 02/07/2023] Open
Abstract
The in vitro micronucleus (MN) assay is a well-established assay for quantification of DNA damage, and is required by regulatory bodies worldwide to screen chemicals for genetic toxicity. The MN assay is performed in two variations: scoring MN in cytokinesis-blocked binucleated cells or directly in unblocked mononucleated cells. Several methods have been developed to score the MN assay, including manual and automated microscopy, and conventional flow cytometry, each with advantages and limitations. Previously, we applied imaging flow cytometry (IFC) using the ImageStream® to develop a rapid and automated MN assay based on high throughput image capture and feature-based image analysis in the IDEAS® software. However, the analysis strategy required rigorous optimization across chemicals and cell lines. To overcome the complexity and rigidity of feature-based image analysis, in this study we used the Amnis® AI software to develop a deep-learning method based on convolutional neural networks to score IFC data in both the cytokinesis-blocked and unblocked versions of the MN assay. We show that the use of the Amnis AI software to score imagery acquired using the ImageStream® compares well to manual microscopy and outperforms IDEAS® feature-based analysis, facilitating full automation of the MN assay.
Collapse
Affiliation(s)
| | | | - Artiom Zayats
- Amnis Flow Cytometry, Luminex Corporation, Seattle, WA, USA
| | - Bryan Davidson
- Amnis Flow Cytometry, Luminex Corporation, Seattle, WA, USA
| | - Michael Riedel
- Amnis Flow Cytometry, Luminex Corporation, Seattle, WA, USA
| | - Yang Li
- Amnis Flow Cytometry, Luminex Corporation, Seattle, WA, USA
| | | |
Collapse
|
23
|
Shuryak I, Turner HC, Pujol-Canadell M, Perrier JR, Garty G, Brenner DJ. Machine learning methodology for high throughput personalized neutron dose reconstruction in mixed neutron + photon exposures. Sci Rep 2021; 11:4022. [PMID: 33597632 PMCID: PMC7889851 DOI: 10.1038/s41598-021-83575-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 02/04/2021] [Indexed: 11/09/2022] Open
Abstract
We implemented machine learning in the radiation biodosimetry field to quantitatively reconstruct neutron doses in mixed neutron + photon exposures, which are expected in improvised nuclear device detonations. Such individualized reconstructions are crucial for triage and treatment because neutrons are more biologically damaging than photons. We used a high-throughput micronucleus assay with automated scanning/imaging on lymphocytes from human blood ex-vivo irradiated with 44 different combinations of 0-4 Gy neutrons and 0-15 Gy photons (542 blood samples), which include reanalysis of past experiments. We developed several metrics that describe micronuclei/cell probability distributions in binucleated cells, and used them as predictors in random forest (RF) and XGboost machine learning analyses to reconstruct the neutron dose in each sample. The probability of "overfitting" was minimized by training both algorithms with repeated cross-validation on a randomly-selected subset of the data, and measuring performance on the rest. RF achieved the best performance. Mean R2 for actual vs. reconstructed neutron doses over 300 random training/testing splits was 0.869 (range 0.761 to 0.919) and root mean squared error was 0.239 (0.195 to 0.351) Gy. These results demonstrate the promising potential of machine learning to reconstruct the neutron dose component in clinically-relevant complex radiation exposure scenarios.
Collapse
Affiliation(s)
- Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA.
| | - Helen C Turner
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| | - Monica Pujol-Canadell
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| | - Jay R Perrier
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| | - Guy Garty
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| |
Collapse
|
24
|
Allemang A, Thacker R, DeMarco RA, Rodrigues MA, Pfuhler S. The 3D reconstructed skin micronucleus assay using imaging flow cytometry and deep learning: A proof-of-principle investigation. Mutat Res 2021; 865:503314. [PMID: 33865536 DOI: 10.1016/j.mrgentox.2021.503314] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 01/13/2021] [Accepted: 01/18/2021] [Indexed: 10/22/2022]
Abstract
The reconstructed skin micronucleus (RSMN) assay was developed in 2006, as an in vitro alternative for genotoxicity evaluation of dermally applied chemicals or products. In the years since, significant progress has been made in the optimization of the assay, including publication of a standard protocol and extensive validation. However, the diverse morphology of skin cells makes cell preparation and scoring of micronuclei (MN) tedious and subjective, thus requiring a high level of technical expertise for evaluation. This ultimately has a negative impact on throughput and the assay would benefit by the development of an automated method which could reduce scoring subjectivity while also improving the robustness of the assay by increasing the number of cells that can be scored. Imaging flow cytometry (IFC) with the ImageStream®X Mk II can capture high-resolution transmission and fluorescent imagery of cells in suspension. This proof-of-principle study describes protocol modifications that enable such automated measurement in 3D skin cells following exposure to mitomycin C and colchicine. IFC was then used for automated image capture and the Amnis® Artificial Intelligence (AAI) software permitted identification of binucleated (BN) cells with 91% precision. On average, three times as many BN cells from control samples were evaluated using IFC compared to the standard manual analysis. When IFC MNBN cells were visually scored from within the BN cell images, their frequency compared well with manual slide scoring, showing that IFC technology can be applied to the RSMN assay. This method enables faster time to result than microscope-based scoring and the initial studies presented here demonstrate its capability for the detection of statistically significant increases in MNBN frequencies. This work therefore demonstrates the feasibility of combining IFC and AAI to automate scoring for the RSMN assay and to improve its throughput and statistical robustness.
Collapse
Affiliation(s)
| | - Robert Thacker
- Amnis Flow Cytometry, Luminex Corporation, Austin, TX, USA
| | | | | | | |
Collapse
|
25
|
Goh VST, Nakayama R, Blakely WF, Abe Y, Chua CEL, Chew ZH, Nakata A, Fujishima Y, Yoshida MA, Kasai K, Ariyoshi K, Miura T. Improved harvest and fixation methodology for isolated human peripheral blood mononuclear cells in cytokinesis-block micronucleus assay. Int J Radiat Biol 2020; 97:194-207. [PMID: 33135957 DOI: 10.1080/09553002.2021.1844338] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE In suspected radiation exposures, cytokinesis-block micronucleus (CBMN) assay is used for biodosimetry by detecting micronuclei (MN) in binucleated (BN) cells in whole blood and isolated peripheral blood mononuclear cell (PBMC) cultures. Standardized harvest protocols for whole blood were published by the International Atomic Energy Agency (IAEA) in 2001 (Technical report no. 405) and 2011 (EPR-Biodosimetry). For isolated PBMC harvest, cytocentrifugation of fresh cells is recommended to preserve cytoplasmic boundaries for MN scoring. However, cytocentrifugation utilizes specialized equipment and long-term cell suspension storage is difficult. In this study, an alternative CBMN harvest protocol is proposed for laboratories interested in culturing PBMCs and storing fixed cells with routine biodosimetry methods. MATERIALS AND METHODS Peripheral blood from 4 males (24, 34, 41, 51 y.o.) and females (26, 37, 44, 56 y.o.) was irradiated with 0 and 2 Gy X-rays. For cells harvested with IAEA 2001 and 2011 protocols, whole blood was used. For cells harvested with our protocol (CRG), isolated PBMCs were used. CRG protocol was validated in DAPI, acridine orange and Giemsa stain, and in three other laboratories. Cytoplasm status, nuclear division index (NDI) and induced MN frequency (MN frequency at 2 Gy - background MN frequency at 0 Gy) (MN/1000 BN) of Giemsa-stained BN cells were compared in IAEA 2001, IAEA 2011, IAEA 2011 + formaldehyde (FA) and CRG protocols. Effects of low and high humidity spreading were evaluated. RESULTS >94% of 1000 BN cells were scorable with clear cytoplasmic boundaries in all donors harvested with CRG protocol. FA addition in IAEA 2011 protocol reduced cell rupture in whole blood cultures, but cell rupture was affected by age, sex and humidity. Almost all cells harvested with IAEA 2001 protocol had cytoplasm loss. PBMCs harvested with CRG protocol stained well in DAPI, acridine orange and Giemsa, and showed high scorable BN frequency in all laboratories. A higher NDI and a lower induced MN frequency were seen in 2 Gy isolated PBMC than whole blood cultures. CONCLUSION This quick CBMN harvest protocol for isolated PBMCs is a viable alternative to cytocentrifugation, as many scorable BN cells were obtained with routine biodosimetry reagents and equipment. IAEA 2011 + FA protocol should be used to improve CBMN harvest in whole blood cultures. Humidity during spreading should be optimized depending on the harvest protocol. NDI and MN frequency should be separately evaluated for whole blood and isolated PBMC cultures.
Collapse
Affiliation(s)
- Valerie Swee Ting Goh
- Department of Bioscience and Laboratory Medicine, Hirosaki University Graduate School of Health Sciences, Hirosaki, Japan
| | - Ryo Nakayama
- Department of Bioscience and Laboratory Medicine, Hirosaki University Graduate School of Health Sciences, Hirosaki, Japan
| | - William F Blakely
- Scientific Research Department, Armed Forces Radiobiology Research Institute (AFRRI), Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Yu Abe
- Department of Radiation Life Sciences, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - Christelle En Lin Chua
- Department of Radiobiology, Singapore Nuclear Research and Safety Initiative (SNRSI), Singapore, Singapore
| | - Zi Huai Chew
- Department of Radiobiology, Singapore Nuclear Research and Safety Initiative (SNRSI), Singapore, Singapore
| | - Akifumi Nakata
- Department of Basic Pharmacy, Hokkaido Pharmaceutical University School of Pharmacy, Otaru, Japan
| | - Yohei Fujishima
- Department of Radiation Biology, Tohoku University School of Medicine, Sendai, Japan
| | | | - Kosuke Kasai
- Department of Bioscience and Laboratory Medicine, Hirosaki University Graduate School of Health Sciences, Hirosaki, Japan
| | - Kentaro Ariyoshi
- Integrated Center for Science and Humanities, Fukushima Medical University, Fukushima, Japan
| | - Tomisato Miura
- Department of Risk Analysis and Biodosimetry, Institute of Radiation Emergency Medicine, Hirosaki, Japan
| |
Collapse
|
26
|
Garty G, Xu Y, Johnson GW, Smilenov LB, Joseph SK, Pujol-Canadell M, Turner HC, Ghandhi SA, Wang Q, Shih R, Morton RC, Cuniberti DE, Morton SR, Bueno-Beti C, Morgan TL, Caracappa PF, Laiakis EC, Fornace AJ, Amundson SA, Brenner DJ. VADER: a variable dose-rate external 137Cs irradiator for internal emitter and low dose rate studies. Sci Rep 2020; 10:19899. [PMID: 33199728 PMCID: PMC7670416 DOI: 10.1038/s41598-020-76941-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 11/03/2020] [Indexed: 11/08/2022] Open
Abstract
In the long term, 137Cs is probably the most biologically important agent released in many accidental (or malicious) radiation disasters. It can enter the food chain, and be consumed, or, if present in the environment (e.g. from fallout), can provide external irradiation over prolonged times. In either case, due to the high penetration of the energetic γ rays emitted by 137Cs, the individual will be exposed to a low dose rate, uniform, whole body, irradiation. The VADER (VAriable Dose-rate External 137Cs irradiatoR) allows modeling these exposures, bypassing many of the problems inherent in internal emitter studies. Making use of discarded 137Cs brachytherapy seeds, the VADER can provide varying low dose rate irradiations at dose rates of 0.1 to 1.2 Gy/day. The VADER includes a mouse "hotel", designed to allow long term simultaneous residency of up to 15 mice. Two source platters containing ~ 250 mCi each of 137Cs brachytherapy seeds are mounted above and below the "hotel" and can be moved under computer control to provide constant low dose rate or a varying dose rate mimicking 137Cs biokinetics in mouse or man. We present the VADER design and characterization of its performance over 18 months of use.
Collapse
Affiliation(s)
- Guy Garty
- Radiological Research Accelerator Facility, Columbia University, 136 S. Broadway, Box 21, Irvington, NY, 10533, USA.
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA.
| | - Yanping Xu
- Radiological Research Accelerator Facility, Columbia University, 136 S. Broadway, Box 21, Irvington, NY, 10533, USA
| | - Gary W Johnson
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - Lubomir B Smilenov
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - Simon K Joseph
- David A. Gardner PET Imaging Research Center, Columbia University, New York, NY, 10032, USA
| | | | - Helen C Turner
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - Shanaz A Ghandhi
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - Qi Wang
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - Rompin Shih
- Department of Radiation Oncology, Columbia University, New York, NY, 10032, USA
| | - Robert C Morton
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - David E Cuniberti
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - Shad R Morton
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - Carlos Bueno-Beti
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - Thomas L Morgan
- Environmental Health and Safety, Columbia University, New York, NY, 10032, USA
| | - Peter F Caracappa
- Environmental Health and Safety, Columbia University, New York, NY, 10032, USA
| | - Evagelia C Laiakis
- Department of Oncology, Lombardi Comprehensive Cancer Center, Georgetown University, Washington DC, 20057, USA
- Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington DC, 20057, USA
| | - Albert J Fornace
- Department of Oncology, Lombardi Comprehensive Cancer Center, Georgetown University, Washington DC, 20057, USA
- Department of Biochemistry and Molecular and Cellular Biology, Georgetown University, Washington DC, 20057, USA
| | - Sally A Amundson
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University, New York, NY, 10032, USA
| |
Collapse
|
27
|
Shuryak I, Ghandhi SA, Turner HC, Weber W, Melo D, Amundson SA, Brenner DJ. Dose and Dose-Rate Effects in a Mouse Model of Internal Exposure from 137Cs. Part 2: Integration of Gamma-H2AX and Gene Expression Biomarkers for Retrospective Radiation Biodosimetry. Radiat Res 2020; 196:491-500. [PMID: 33064820 PMCID: PMC8944909 DOI: 10.1667/rade-20-00042.1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Accepted: 08/13/2020] [Indexed: 11/03/2022]
Abstract
Inhalation and ingestion of 137Cs and other long-lived radionuclides can occur after large-scale accidental or malicious radioactive contamination incidents, resulting in a complex temporal pattern of radiation dose/dose rate, influenced by radionuclide pharmacokinetics and chemical properties. High-throughput radiation biodosimetry techniques for such internal exposure are needed to assess potential risks of short-term toxicity and delayed effects (e.g., carcinogenesis) for exposed individuals. Previously, we used γ-H2AX to reconstruct injected 137Cs activity in experimentally-exposed mice, and converted activity values into radiation doses based on time since injection and 137Cs-elimination kinetics. In the current study, we sought to assess the feasibility and possible advantages of combining γ-H2AX with transcriptomics to improve 137Cs activity reconstructions. We selected five genes (Atf5, Hist2h2aa2, Olfr358, Psrc1, Hist2h2ac) with strong statistically-significant Spearman's correlations with injected activity and stable expression over time after 137Cs injection. The geometric mean of log-transformed signals of these five genes, combined with γ-H2AX fluorescence, were used as predictors in a nonlinear model for reconstructing injected 137Cs activity. The coefficient of determination (R2) comparing actual and reconstructed activities was 0.91 and root mean squared error (RMSE) was 0.95 MBq. These metrics remained stable when the model was fitted to a randomly-selected half of the data and tested on the other half, repeated 100 times. Model performance was significantly better when compared to our previous analysis using γ-H2AX alone, and when compared to an analysis where genes are used without γ-H2AX, suggesting that integrating γ-H2AX with gene expression provides an important advantage. Our findings show a proof of principle that integration of radiation-responsive biomarkers from different fields is promising for radiation biodosimetry of internal emitters.
Collapse
Affiliation(s)
- Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Shanaz A. Ghandhi
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Helen C. Turner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - Waylon Weber
- Lovelace Biomedical, Albuquerque, New Mexico, 87108
| | | | - Sally A. Amundson
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| | - David J. Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, New York 10032
| |
Collapse
|
28
|
|
29
|
Wang Q, Lee Y, Shuryak I, Pujol Canadell M, Taveras M, Perrier JR, Bacon BA, Rodrigues MA, Kowalski R, Capaccio C, Brenner DJ, Turner HC. Development of the FAST-DOSE assay system for high-throughput biodosimetry and radiation triage. Sci Rep 2020; 10:12716. [PMID: 32728041 PMCID: PMC7392759 DOI: 10.1038/s41598-020-69460-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Accepted: 07/09/2020] [Indexed: 11/09/2022] Open
Abstract
Following a large-scale radiological incident, there is a need for FDA-approved biodosimetry devices and biomarkers with the ability to rapidly determine past radiation exposure with sufficient accuracy for early population triage and medical management. Towards this goal, we have developed FAST-DOSE (Fluorescent Automated Screening Tool for Dosimetry), an immunofluorescent, biomarker-based system designed to reconstruct absorbed radiation dose in peripheral blood samples collected from potentially exposed individuals. The objective of this study was to examine the performance of the FAST-DOSE assay system to quantify intracellular protein changes in blood leukocytes for early biodosimetry triage from humanized NOD-scid-gamma (Hu-NSG) mice and non-human primates (NHPs) exposed to ionizing radiation up to 8 days after radiation exposure. In the Hu-NSG mice studies, the FAST-DOSE biomarker panel was able to generate delivered dose estimates at days 1, 2 and 3 post exposure, whereas in the NHP studies, the biomarker panel was able to successfully classify samples by dose categories below or above 2 Gy up to 8 days after total body exposure. These results suggest that the FAST-DOSE bioassay has large potential as a useful diagnostic tool for rapid and reliable screening of potentially exposed individuals to aid early triage decisions within the first week post-exposure.
Collapse
Affiliation(s)
- Qi Wang
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
- Radiation Oncology, Columbia University Irving Medical Center, New York, NY, 10032, USA.
| | - Younghyun Lee
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Monica Pujol Canadell
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Maria Taveras
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Jay R Perrier
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
- ASELL, LLC, Owings Mills, MD, 21117, USA
| | - Bezalel A Bacon
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | | | | | | | - David J Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Helen C Turner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
| |
Collapse
|
30
|
Swartz HM, Flood AB, Singh VK, Swarts SG. Scientific and Logistical Considerations When Screening for Radiation Risks by Using Biodosimetry Based on Biological Effects of Radiation Rather than Dose: The Need for Prior Measurements of Homogeneity and Distribution of Dose. HEALTH PHYSICS 2020; 119:72-82. [PMID: 32175928 PMCID: PMC7269859 DOI: 10.1097/hp.0000000000001244] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
An effective medical response to a large-scale radiation event requires prompt and effective initial triage so that appropriate care can be provided to individuals with significant risk for severe acute radiation injury. Arguably, it would be advantageous to use injury rather than radiation dose for the initial assessment; i.e., use bioassays of biological damage. Such assays would be based on changes in intrinsic biological response elements; e.g., up- or down-regulation of genes, proteins, metabolites, blood cell counts, chromosomal aberrations, micronuclei, micro-RNA, cytokines, or transcriptomes. Using a framework to evaluate the feasibility of biodosimetry for triaging up to a million people in less than a week following a major radiation event, Part 1 analyzes the logistical feasibility and clinical needs for ensuring that biomarkers of organ-specific injury could be effectively used in this context. We conclude that the decision to use biomarkers of organ-specific injury would greatly benefit by first having independent knowledge of whether the person's exposure was heterogeneous and, if so, what was the dose distribution (to determine which organs were exposed to high doses). In Part 2, we describe how these two essential needs for prior information (heterogeneity and dose distribution) could be obtained by using in vivo nail dosimetry. This novel physical biodosimetry method can also meet the needs for initial triage, providing non-invasive, point-of-care measurements made by non-experts with immediate dose estimates for four separate anatomical sites. Additionally, it uniquely provides immediate information as to whether the exposure was homogeneous and, if not, it can estimate the dose distribution. We conclude that combining the capability of methods such as in vivo EPR nail dosimetry with bioassays to predict organ-specific damage would allow effective use of medical resources to save lives.
Collapse
Affiliation(s)
- Harold M. Swartz
- Dept of Radiology, Geisel School of Medicine at Dartmouth College, Hanover, NH USA
- Dept of Medicine/Radiation Oncology, Geisel School of Medicine at Dartmouth College, Hanover, NH USA
| | - Ann Barry Flood
- Dept of Radiology, Geisel School of Medicine at Dartmouth College, Hanover, NH USA
| | - Vijay K. Singh
- Dept. Pharmacology & Molecular Therapeutics, F. Edward Hébert School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
- Armed Forces Radiobiology Research Institute, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Steven G. Swarts
- Dept of Radiation Oncology, University of Florida, Gainesville, FL, USA
| |
Collapse
|
31
|
Herate C, Sabatier L. Retrospective biodosimetry techniques: Focus on cytogenetics assays for individuals exposed to ionizing radiation. MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH 2020; 783:108287. [PMID: 32192645 DOI: 10.1016/j.mrrev.2019.108287] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 09/26/2019] [Accepted: 11/01/2019] [Indexed: 01/28/2023]
Abstract
In the absence of physical data, biodosimetry tools are required for fast dose and risk assessment in the event of radiological or nuclear mass accidents or attacks to triage exposed humans and take immediate medical countermeasures. Biodosimetry tools have mostly been developed for retrospective dose assessment and the follow-up of victims of irradiation. Among them, cytogenetics analyses, to reveal chromosome damage, are the most developed and allow the determination of doses from blood samples as low as 100 mGy. Various cytogenetic tests have already allowed retrospective dose assessment of Chernobyl liquidators and military personnel exposed to nuclear tests after decades. In this review, we discuss the properties of various biodosimetry techniques, such as their sensitivity and limitations as a function of the time from exposure, using multiple examples of nuclear catastrophes or working exposure. Among them, chromosome FISH hybridization, which reveals chromosome translocations, is the most reliable due to the persistence of translocations for decades, whereas dicentric chromosome and micronuclei assays allow rapid and accurate dose assessment a short time after exposure. Both need to be adjusted through mathematical algorithms for retrospective analyses, accounting for the time since exposure and the victims' age. The goal for the future will be to better model chromosome damage, reduce the time to result, and develop new complementary biodosimetry approaches, such as mutation signatures.
Collapse
Affiliation(s)
- C Herate
- PROCyTox, French Alternative Energies and Atomic Energy Commission (CEA), University Paris-Saclay, Fontenay-aux-Roses, France
| | - L Sabatier
- PROCyTox, French Alternative Energies and Atomic Energy Commission (CEA), University Paris-Saclay, Fontenay-aux-Roses, France.
| |
Collapse
|
32
|
Wang Q, Pujol-Canadell M, Taveras M, Garty G, Perrier J, Bueno-Beti C, Shuryak I, Brenner DJ, Turner HC. DNA damage response in peripheral mouse blood leukocytes in vivo after variable, low-dose rate exposure. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2020; 59:89-98. [PMID: 31897603 PMCID: PMC7441378 DOI: 10.1007/s00411-019-00825-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Accepted: 12/08/2019] [Indexed: 05/03/2023]
Abstract
Environmental contamination and ingestion of the radionuclide Cesium-137 (137Cs) is a large concern in fallout from a nuclear reactor accident or improvised nuclear device, and highlights the need to develop biological assays for low-dose rate, internal emitter radiation. To mimic low-dose rates attributable to fallout, we have developed a VAriable Dose-rate External 137Cs irradiatoR (VADER), which can provide arbitrarily varying and progressive low-dose rate irradiations in the range of 0.1-1.2 Gy/day, while circumventing the complexities of dealing with radioactively contaminated biomaterials. We investigated the kinetics of mouse peripheral leukocytes DNA damage response in vivo after variable, low-dose rate 137Cs exposure. C57BL/6 mice were placed in the VADER over 7 days with total accumulated dose up to 2.7 Gy. Peripheral blood response including the leukocyte depletion, apoptosis as well as its signal protein p53 and DNA repair biomarker γ-H2AX was measured. The results illustrated that blood leukocyte numbers had significantly dropped by day 7. P53 levels peaked at day 2 (total dose = 0.91 Gy) and then declined; whereas, γ-H2AX fluorescence intensity (MFI) and foci number generally increased with accumulated dose and peaked at day 5 (total dose = 2.08 Gy). ROC curve analysis for γ-H2AX provided a good discrimination of accumulated dose < 2 Gy and ≥ 2 Gy, highlighting the potential of γ-H2AX MFI as a biomarker for dosimetry in a protracted, environmental exposure scenario.
Collapse
Affiliation(s)
- Qi Wang
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
| | - Monica Pujol-Canadell
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Maria Taveras
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Guy Garty
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Jay Perrier
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Carlos Bueno-Beti
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Helen C Turner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| |
Collapse
|
33
|
Micronucleus Assay: The State of Art, and Future Directions. Int J Mol Sci 2020; 21:ijms21041534. [PMID: 32102335 PMCID: PMC7073234 DOI: 10.3390/ijms21041534] [Citation(s) in RCA: 141] [Impact Index Per Article: 28.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 02/13/2020] [Accepted: 02/14/2020] [Indexed: 12/16/2022] Open
Abstract
During almost 40 years of use, the micronucleus assay (MN) has become one of the most popular methods to assess genotoxicity of different chemical and physical factors, including ionizing radiation-induced DNA damage. In this minireview, we focus on the position of MN among the other genotoxicity tests, its usefulness in different applications and visibility by international organizations, such as International Atomic Energy Agency, Organization for Economic Co-operation and Development and International Organization for Standardization. In addition, the mechanism of micronuclei formation is discussed. Finally, foreseen directions of the MN development are pointed, such as automation, buccal cells MN and chromothripsis phenomenon.
Collapse
|
34
|
Shuryak I, Turner HC, Perrier JR, Cunha L, Canadell MP, Durrani MH, Harken A, Bertucci A, Taveras M, Garty G, Brenner DJ. A High Throughput Approach to Reconstruct Partial-Body and Neutron Radiation Exposures on an Individual Basis. Sci Rep 2020; 10:2899. [PMID: 32076014 PMCID: PMC7031285 DOI: 10.1038/s41598-020-59695-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Accepted: 01/27/2020] [Indexed: 11/28/2022] Open
Abstract
Biodosimetry-based individualized reconstruction of complex irradiation scenarios (partial-body shielding and/or neutron + photon mixtures) can improve treatment decisions after mass-casualty radiation-related incidents. We used a high-throughput micronucleus assay with automated scanning and imaging software on ex-vivo irradiated human lymphocytes to: a) reconstruct partial-body and/or neutron exposure, and b) estimate separately the photon and neutron doses in a mixed exposure. The mechanistic background is that, compared with total-body photon irradiations, neutrons produce more heavily-damaged lymphocytes with multiple micronuclei/binucleated cell, whereas partial-body exposures produce fewer such lymphocytes. To utilize these differences for biodosimetry, we developed metrics that describe micronuclei distributions in binucleated cells and serve as predictors in machine learning or parametric analyses of the following scenarios: (A) Homogeneous gamma-irradiation, mimicking total-body exposures, vs. mixtures of irradiated blood with unirradiated blood, mimicking partial-body exposures. (B) X rays vs. various neutron + photon mixtures. The results showed high accuracies of scenario and dose reconstructions. Specifically, receiver operating characteristic curve areas (AUC) for sample classification by exposure type reached 0.931 and 0.916 in scenarios A and B, respectively. R2 for actual vs. reconstructed doses in these scenarios reached 0.87 and 0.77, respectively. These encouraging findings demonstrate a proof-of-principle for the proposed approach of high-throughput reconstruction of clinically-relevant complex radiation exposure scenarios.
Collapse
Affiliation(s)
- Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA.
| | - Helen C Turner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - Jay R Perrier
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - Lydia Cunha
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - Monica Pujol Canadell
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - Mohammad H Durrani
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - Andrew Harken
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - Antonella Bertucci
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - Maria Taveras
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - Guy Garty
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| |
Collapse
|
35
|
Repin M, Pampou S, Brenner DJ, Garty G. The use of a centrifuge-free RABiT-II system for high-throughput micronucleus analysis. JOURNAL OF RADIATION RESEARCH 2020; 61:68-72. [PMID: 31825079 PMCID: PMC6976732 DOI: 10.1093/jrr/rrz074] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 09/16/2019] [Accepted: 10/15/2019] [Indexed: 06/10/2023]
Abstract
The cytokinesis-block micronucleus (CBMN) assay is considered to be the most suitable biodosimetry method for automation. Previously, we automated this assay on a commercial robotic biotech high-throughput system (RABiT-II) adopting both a traditional and an accelerated micronucleus protocol, using centrifugation steps for both lymphocyte harvesting and washing, after whole blood culturing. Here we describe further development of our accelerated CBMN assay protocol for use on high-throughput/high content screening (HTS/HCS) robotic systems without a centrifuge. This opens the way for implementation of the CBMN assay on a wider range of commercial automated HTS/HCS systems and thus increases the potential capacity for dose estimates following a mass-casualty radiological event.
Collapse
Affiliation(s)
- Mikhail Repin
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Sergey Pampou
- Columbia Genome Center High Throughput Screening Facility, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Guy Garty
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA
- Radiological Research Accelerator Facility, Columbia University Irving Medical Center, Irvington, NY, 10533, USA
| |
Collapse
|
36
|
Lee Y, Wang Q, Shuryak I, Brenner DJ, Turner HC. Development of a high-throughput γ-H2AX assay based on imaging flow cytometry. Radiat Oncol 2019; 14:150. [PMID: 31438980 PMCID: PMC6704696 DOI: 10.1186/s13014-019-1344-7] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 07/23/2019] [Indexed: 11/30/2022] Open
Abstract
Background Measurement of γ-H2AX foci levels in cells provides a sensitive and reliable method for quantitation of the radiation-induced DNA damage response. The objective of the present study was to develop a rapid, high-throughput γ-H2AX assay based on imaging flow cytometry (IFC) using the ImageStream®X Mk II (ISX) platform to evaluate DNA double strand break (DSB) repair kinetics in human peripheral blood cells after exposure to ionizing irradiation. Methods The γ-H2AX protocol was developed and optimized for small volumes (100 μL) of human blood in Matrix™ 96-tube format. Blood cell lymphocytes were identified and captured by ISX INSPIRE™ software and analyzed by Data Exploration and Analysis Software. Results Dose- and time-dependent γ-H2AX levels corresponding to radiation exposure were measured at various time points over 24 h using the IFC system. γ-H2AX fluorescence intensity at 1 h after exposure, increased linearly with increasing radiation dose (R2 = 0.98) for the four human donors tested, whereas the dose response for the mean number of γ-H2AX foci/cell was not as robust (R2 = 0.81). Radiation-induced γ-H2AX levels rapidly increased within 30 min and reached a maximum by ~ 1 h, after which time there was fast decline by 6 h, followed by a much slower rate of disappearance up to 24 h. A mathematical approach for quantifying DNA repair kinetics using the rate of γ-H2AX decay (decay constant, Kdec), and yield of residual unrepaired breaks (Fres) demonstrated differences in individual repair capacity between the healthy donors. Conclusions The results indicate that the IFC-based γ-H2AX protocol may provide a practical and high-throughput platform for measurements of individual global DNA DSB repair capacity which can facilitate precision medicine by predicting individual radiosensitivity and risk of developing adverse effects related to radiotherapy treatment. Electronic supplementary material The online version of this article (10.1186/s13014-019-1344-7) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Younghyun Lee
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th St, New York, NY, 10032, USA. .,Present Address: Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, 75 Nowon-ro, Nowon-gu, Seoul, 01812, Republic of Korea.
| | - Qi Wang
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th St, New York, NY, 10032, USA
| | - Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th St, New York, NY, 10032, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th St, New York, NY, 10032, USA
| | - Helen C Turner
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th St, New York, NY, 10032, USA
| |
Collapse
|