1
|
Feng C, Li J, Yang W, Chen Z. Study on the inactivation effect and mechanism of EGCG disinfectant on Bacillus subtilis. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 356:124364. [PMID: 38878811 DOI: 10.1016/j.envpol.2024.124364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 06/06/2024] [Accepted: 06/11/2024] [Indexed: 06/22/2024]
Abstract
The widespread use of chlorine-based disinfectants in drinking water treatment has led to the proliferation of chlorine-resistant bacteria and the risk of disinfection byproducts (DBPs), posing a serious threat to public health. This study aims to explore the effectiveness and potential applications of epigallocatechin gallate (EGCG) against chlorine-resistant Bacillus and its spores in water, providing new insights for the control of chlorine-resistant bacteria and improving the biological stability of distribution systems. The inactivation effects of EGCG on Bacillus subtilis (B. subtilis) and its spores were investigated using transmission electron microscopy, ATP measurement, and transcriptome sequencing analysis to determine changes in surface structure, energy metabolism, and gene expression levels, thereby elucidating the inactivation mechanism. The results demonstrate the potential application of EGCG in continuously inhibiting chlorine-resistant B. subtilis in water, effectively improving the biological stability of the distribution system. However, EGCG is not suitable for treating raw water with high spore content and is more suitable as a supplementary disinfectant for processes with strong spore removal capabilities, such as ozone, ultraviolet, or ultrafiltration. EGCG exhibits a disruptive effect on the morphological structure and energy metabolism of B. subtilis and suppresses the synthesis of substances, energy metabolism, and normal operation of the antioxidant system by inhibiting the expression of multiple genes, thereby achieving the inactivation of B. subtilis.
Collapse
Affiliation(s)
- Cuimin Feng
- Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing, 100044, China; National Demonstration Center for Experimental Water Environment Education, Beijing University of Civil Engineering and Architecture, Beijing, 100044, China.
| | - Jing Li
- Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing, 100044, China; National Demonstration Center for Experimental Water Environment Education, Beijing University of Civil Engineering and Architecture, Beijing, 100044, China
| | - Weiqi Yang
- Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing, 100044, China; National Demonstration Center for Experimental Water Environment Education, Beijing University of Civil Engineering and Architecture, Beijing, 100044, China
| | - Zexin Chen
- Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing, 100044, China; National Demonstration Center for Experimental Water Environment Education, Beijing University of Civil Engineering and Architecture, Beijing, 100044, China
| |
Collapse
|
2
|
Wang X, Zheng Z, Man JHK, Lo IMC. Regulating charge transfer for enhanced PAA activation over sulfur-doped magnetic CoFe 2O 4: A novel strategy for simultaneous micropollutants degradation and bacteria inactivation. WATER RESEARCH 2024; 256:121595. [PMID: 38640561 DOI: 10.1016/j.watres.2024.121595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 04/05/2024] [Accepted: 04/08/2024] [Indexed: 04/21/2024]
Abstract
Micropollutants and bacteria are prevalent pollutants in wastewater, posing significant risks to ecosystems and human health. As peracetic acid (PAA) is being increasingly used as a disinfectant, activation of PAA by low-cost and high-performance activators is a promising strategy for wastewater treatment. In this study, the sulfur-doped magnetic CoFe2O4 (SCFO) is successfully developed for efficient PAA activation to simultaneously decontaminate and disinfect wastewater. PAA/SCFO-0.3 exhibits exceptional performance, degrading 100 % of 8 μM sulfamethoxazole (SMX) with a first-pseudo reaction rate of 1.275 min-1, and achieving 5.3-log inactivation of Escherichia coli (E. coli) within 3 min at a PAA dosage of 0.2 mM and catalyst dosage of 0.025 g/L (initial pH 6.5). Scavenging experiments and electron paramagnetic resonance (EPR) analysis identify CH3C(O)O• and CH3C(O)OO• as the dominant reactive species for SMX degradation. The sulfur species in SCFO-0.3 facilitate Co2+ regeneration and regulate charge transfer, promoting PAA activation for SMX degradation. Moreover, the PAA/SCFO-0.3 system demonstrates operational feasibility over a broad range of water matrices and has excellent stability and reusability (maintaining 93 % removal of SMX after 5 cycles), demonstrating its potential for industrial applications. This study provides insights into enhancing PAA activation through sulfur doping in transition metal catalysts and highlights the practical applicability of the PAA/SCFO-0.3 system as an advanced alternative to conventional disinfection for simultaneous decontamination and disinfection in wastewater.
Collapse
Affiliation(s)
- Xiaoying Wang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Hong Kong, China
| | - Zexiao Zheng
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Hong Kong, China
| | - Justin H K Man
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Hong Kong, China
| | - Irene M C Lo
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Hong Kong, China; Institute for Advanced Study, The Hong Kong University of Science and Technology, Hong Kong, China.
| |
Collapse
|
3
|
Yu Y, Xia L, Yan H, Lu Y. Effects of 8 weeks parent-accompanied swimming on physical capacity and intelligence in preschool children. Front Public Health 2024; 12:1410707. [PMID: 38883199 PMCID: PMC11176541 DOI: 10.3389/fpubh.2024.1410707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Accepted: 05/20/2024] [Indexed: 06/18/2024] Open
Abstract
This study aimed to explore the potential effects of 8-week parents-accompanied swimming on the physical capacity and intelligence of preschool children in China. Thirty-six boys (mean age 3.56 ± 0.27 years) were divided into three groups: the traditional physical exercise group (TP, n = 12), the accompanied swimming group (AS, n = 12) and the independent swimming group (IS, n = 12). Participants' physical capacity was assessed before and after the intervention using the following indicators: height, weight, distance of tennis ball throw, standing long jump distance, time for the 10-meter shuttle run, time for a two-legged continuous jump, sit-and-reach distance, and time on the walking balance beam. Intelligence was assessed at three points: pre-test, mid-test after 4 weeks, and post-test. Data were analyzed using a two-way repeated measures ANOVA, Bonferroni test (p < 0.05) and effect size. The time of the AS and IS groups to walk the balance beam was significantly lower than the TP group, with a difference of 1.81 s (p < 0.01, [95% CI -3.22 to -0.40], ES = 1.53) and 1.25 s (p < 0.05, [95% CI -2.66 to 0.16], ES = 0.81). At the mid-test, the IQ scores of the TP group were lower than the AS group (p < 0.05, [95% CI -12.45 to -0.96], ES = 0.89). Additionally, at post-test, the IQ scores of the TP group were significantly lower than those of both AS (p < 0.01, [95% CI -14.12 to -2.74], ES = 1.15) and IS groups (p < 0.01, [95% CI -12.53 to -3.31], ES = 1.21). Swimming enhances children's balance and IQ scores more than traditional physical exercises. Involving parents in swimming leads to a more significant increase in IQ scores within 4 weeks of initial swimming exercise.
Collapse
Affiliation(s)
- Yichao Yu
- The School of Sports Coaching, Beijing Sports University, Beijing, China
- Laboratory of Sports Stress and Adaptation of General Administration of Sport, Beijing Sport University, Beijing, China
| | - Lei Xia
- Shenzhen School Affiliated to Sun Yat-sen University, Shenzhen, China
- The School of Sports Medicine and Rehabilitation, Beijing Sports University, Beijing, China
| | - Huiping Yan
- Laboratory of Sports Stress and Adaptation of General Administration of Sport, Beijing Sport University, Beijing, China
- The School of Sports Medicine and Rehabilitation, Beijing Sports University, Beijing, China
| | - Yifan Lu
- Laboratory of Sports Stress and Adaptation of General Administration of Sport, Beijing Sport University, Beijing, China
- The School of Sports Medicine and Rehabilitation, Beijing Sports University, Beijing, China
| |
Collapse
|
4
|
Karczewska M, Strzelecki P, Szalewska-Pałasz A, Nowicki D. How to Tackle Bacteriophages: The Review of Approaches with Mechanistic Insight. Int J Mol Sci 2023; 24:ijms24054447. [PMID: 36901878 PMCID: PMC10003480 DOI: 10.3390/ijms24054447] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 02/21/2023] [Accepted: 02/22/2023] [Indexed: 02/26/2023] Open
Abstract
Bacteriophage-based applications have a renaissance today, increasingly marking their use in industry, medicine, food processing, biotechnology, and more. However, phages are considered resistant to various harsh environmental conditions; besides, they are characterized by high intra-group variability. Phage-related contaminations may therefore pose new challenges in the future due to the wider use of phages in industry and health care. Therefore, in this review, we summarize the current knowledge of bacteriophage disinfection methods, as well as highlight new technologies and approaches. We discuss the need for systematic solutions to improve bacteriophage control, taking into account their structural and environmental diversity.
Collapse
Affiliation(s)
- Monika Karczewska
- Department of Bacterial Molecular Genetics, Faculty of Biology, University of Gdansk, Wita Stwosza 59, 80-308 Gdansk, Poland
| | - Patryk Strzelecki
- Department of Bacterial Molecular Genetics, Faculty of Biology, University of Gdansk, Wita Stwosza 59, 80-308 Gdansk, Poland
- Institut de Physique et Chimie des Matériaux de Strasbourg, Université de Strasbourg, CNRS, UMR7504, 23 rue du Loess, CEDEX 2, F-67034 Strasbourg, France
| | - Agnieszka Szalewska-Pałasz
- Department of Bacterial Molecular Genetics, Faculty of Biology, University of Gdansk, Wita Stwosza 59, 80-308 Gdansk, Poland
| | - Dariusz Nowicki
- Department of Bacterial Molecular Genetics, Faculty of Biology, University of Gdansk, Wita Stwosza 59, 80-308 Gdansk, Poland
- Correspondence: ; Tel.: +48-58-523-6065
| |
Collapse
|
5
|
Lanrewaju AA, Enitan-Folami AM, Sabiu S, Swalaha FM. A review on disinfection methods for inactivation of waterborne viruses. Front Microbiol 2022; 13:991856. [PMID: 36212890 PMCID: PMC9539188 DOI: 10.3389/fmicb.2022.991856] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 08/29/2022] [Indexed: 11/13/2022] Open
Abstract
Water contamination is a global health problem, and the need for safe water is ever-growing due to the public health implications of unsafe water. Contaminated water could contain pathogenic bacteria, protozoa, and viruses that are implicated in several debilitating human diseases. The prevalence and survival of waterborne viruses differ from bacteria and other waterborne microorganisms. In addition, viruses are responsible for more severe waterborne diseases such as gastroenteritis, myocarditis, and encephalitis among others, hence the need for dedicated attention to viral inactivation. Disinfection is vital to water treatment because it removes pathogens, including viruses. The commonly used methods and techniques of disinfection for viral inactivation in water comprise physical disinfection such as membrane filtration, ultraviolet (UV) irradiation, and conventional chemical processes such as chlorine, monochloramine, chlorine dioxide, and ozone among others. However, the production of disinfection by-products (DBPs) that accompanies chemical methods of disinfection is an issue of great concern due to the increase in the risks of harm to humans, for example, the development of cancer of the bladder and adverse reproductive outcomes. Therefore, this review examines the conventional disinfection approaches alongside emerging disinfection technologies, such as photocatalytic disinfection, cavitation, and electrochemical disinfection. Moreover, the merits, limitations, and log reduction values (LRVs) of the different disinfection methods discussed were compared concerning virus removal efficiency. Future research needs to merge single disinfection techniques into one to achieve improved viral disinfection, and the development of medicinal plant-based materials as disinfectants due to their antimicrobial and safety benefits to avoid toxicity is also highlighted.
Collapse
Affiliation(s)
| | | | - Saheed Sabiu
- Department of Biotechnology and Food Science, Durban University of Technology, Durban, South Africa
| | - Feroz Mahomed Swalaha
- Department of Biotechnology and Food Science, Durban University of Technology, Durban, South Africa
| |
Collapse
|
6
|
Cuevas-Ferrando E, Pérez-Cataluña A, Falcó I, Randazzo W, Sánchez G. Monitoring Human Viral Pathogens Reveals Potential Hazard for Treated Wastewater Discharge or Reuse. Front Microbiol 2022; 13:836193. [PMID: 35464930 PMCID: PMC9026171 DOI: 10.3389/fmicb.2022.836193] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 02/21/2022] [Indexed: 01/22/2023] Open
Abstract
Wastewater discharge to the environment or its reuse after sanitization poses a concern for public health given the risk of transmission of human viral diseases. However, estimating the viral infectivity along the wastewater cycle presents technical challenges and still remains underexplored. Recently, human-associated crAssphage has been investigated to serve as viral pathogen indicator to monitor fecal impacted water bodies, even though its assessment as biomarker for infectious enteric viruses has not been explored yet. To this end, the occurrence of potentially infectious norovirus genogroup I (GI), norovirus GII, hepatitis A virus (HAV), rotavirus A (RV), and human astrovirus (HAstV) along with crAssphage was investigated in influent and effluent water sampled in four wastewater treatment plants (WWTPs) over 1 year by a PMAxx-based capsid integrity RT-qPCR assay. Moreover, influent and effluent samples of a selected WWTP were additionally assayed by an in situ capture RT-qPCR assay (ISC-RT-qPCR) as estimate for viral infectivity in alternative to PMAxx-RT-qPCR. Overall, our results showed lower viral occurrence and concentration assessed by ISC-RT-qPCR than PMAxx-RT-qPCR. Occurrence of potentially infectious enteric virus was estimated by PMAxx-RT-qPCR as 88–94% in influent and 46–67% in effluent wastewaters with mean titers ranging from 4.77 to 5.89, and from 3.86 to 4.97 log10 GC/L, with the exception of HAV that was sporadically detected. All samples tested positive for crAssphage at concentration ranging from 7.41 to 9.99 log10 GC/L in influent and from 4.56 to 6.96 log10 GC/L in effluent wastewater, showing higher mean concentration than targeted enteric viruses. Data obtained by PMAxx-RT-qPCR showed that crAssphage strongly correlated with norovirus GII (ρ = 0.67, p < 0.05) and weakly with HAstV and RV (ρ = 0.25–0.30, p < 0.05) in influent samples. In effluent wastewater, weak (ρ = 0.27–0.38, p < 0.05) to moderate (ρ = 0.47–0.48, p < 0.05) correlations between crAssphage and targeted viruses were observed. Overall, these results corroborate crAssphage as an indicator for fecal contamination in wastewater but a poor marker for either viral occurrence and viral integrity/infectivity. Despite the viral load reductions detected in effluent compared to influent wastewaters, the estimates of viral infectivity based on viability molecular methods might pose a concern for (re)-using of treated water.
Collapse
|
7
|
Patterning of graphene using wet etching with hypochlorite and UV light. Sci Rep 2022; 12:4541. [PMID: 35296771 PMCID: PMC8927452 DOI: 10.1038/s41598-022-08674-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 03/04/2022] [Indexed: 12/04/2022] Open
Abstract
Graphene patterning via etching is important for enhancing or controling the properties of devices and supporting their applications in micro- and nano-electronic fields. Herein, we present a simple, low-cost, and scalable wet etching method for graphene patterning. The technique uses hypochlorite solution combined with ultraviolet light irradiation to rapidly remove unwanted graphene areas from the substrate. Raman spectroscopy, atomic force microscopy, scanning electron microscopy, and optical microscopy results showed that well-patterned graphene with micrometer scale regions was successfully prepared. Furthermore, graphene field effect transistor arrays were fabricated, and the obtained devices exhibited good current–voltage characteristics, with maximum mobility of ~ 1600 cm2/Vs, confirming the feasibility of the developed technique.
Collapse
|
8
|
Monitoring coliphages to reduce waterborne infectious disease transmission in the One Water framework. Int J Hyg Environ Health 2022; 240:113921. [DOI: 10.1016/j.ijheh.2022.113921] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 12/31/2021] [Accepted: 01/05/2022] [Indexed: 02/07/2023]
|
9
|
Luo LW, Wu YH, Chen GQ, Wang HB, Wang YH, Tong X, Bai Y, Xu YQ, Zhang ZW, Ikuno N, Hu HY. Chlorine-resistant bacteria (CRB) in the reverse osmosis system for wastewater reclamation: Isolation, identification and membrane fouling mechanisms. WATER RESEARCH 2022; 209:117966. [PMID: 34952485 DOI: 10.1016/j.watres.2021.117966] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 11/30/2021] [Accepted: 12/12/2021] [Indexed: 06/14/2023]
Abstract
Chlorine disinfection is often used as a pretreatment technology to control biofouling of reverse osmosis (RO) membranes. However, previous studies showed that biofouling of the RO system was aggravated after chlorine disinfection. Chlorine-resistant bacteria (CRB) were presumed to be closely related to the aggravation of fouling caused by chlorine disinfection. In order to analyze the membrane fouling mechanisms of CRB, 5 CRB strains were isolated from the surface of fouled RO membranes for wastewater reclamation, and 3 reference bacterial strains, Sphingopyxis soli BM1-1, Pseudomonas aeruginosa PAO1 and Escherichia coli CGMCC1.3373, were selected for comparative study. The chlorine resistance, membrane fouling potential, secretion and adhesion characteristics of these strains were evaluated. Among these isolated strains, 3 strains showed much higher chlorine resistance than PAO1 under the condition of 0.5, 2, 5 mg/L-Cl2, especially Bacillus CR19 and Bacillus CR2. Furthermore, a significant positive correlation was found between membrane fouling potential and chlorine resistance of all the strains in this study. The membrane fouling potential of the above 8 strains increased monotonically with the increase of chlorine resistance (under the condition of 0.5 mg/L-Cl2). Serious fouling caused by extracellular substances was observed in biofouling layers of the strains with high chlorine resistance, which lead to more severe flux decline. Extracellular polymeric substances (EPS) amount per cell was found to be the main factor related to the chlorine resistance as well as the fouling potential. Computational fluid dynamics (CFD) simulation was used to demonstrate the filtration resistance induced by the secretion of EPS. However, CRB with higher EPS amount may not show higher membrane adhesion potential, and thus may not be the dominant strain on the RO membranes before chlorine disinfection. These CRB with high fouling potential but low membrane adhesion potential, such as Bacillus CR19 and Bacillus CR2, may become the dominant bacteria on the membrane surface after chlorine disinfection and thus aggravate membrane fouling significantly.
Collapse
Affiliation(s)
- Li-Wei Luo
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China
| | - Yin-Hu Wu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China.
| | - Gen-Qiang Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China
| | - Hao-Bin Wang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China
| | - Yun-Hong Wang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China
| | - Xin Tong
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China
| | - Yuan Bai
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China
| | - Yu-Qing Xu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China
| | - Zi-Wei Zhang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China
| | - Nozomu Ikuno
- Kurita Water Industries Ltd., Nakano-ku, Tokyo 164-0001, Japan
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou), Tsinghua, Suzhou, Jiangsu 215163, China
| |
Collapse
|
10
|
Li GQ, Huo ZY, Wu QY, Chen Z, Wu YH, Lu Y, Hu HY. Photolysis of free chlorine and production of reactive radicals in the UV/chlorine system using polychromatic spectrum LEDs as UV sources. CHEMOSPHERE 2022; 286:131828. [PMID: 34416584 DOI: 10.1016/j.chemosphere.2021.131828] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 08/02/2021] [Accepted: 08/05/2021] [Indexed: 06/13/2023]
Abstract
Recently, ultraviolet light-emitting diodes (UV-LEDs) and chlorine combined system has been employed as an emerging advanced oxidation process. However, UV-LEDs were commonly considered as monochromatic UV sources. In this study, the obvious quantum yields of chlorine photolysis under 265 nm and 280 nm LEDs irradiations were investigated with treating LEDs as polychromatic UV sources. Particularly, Φobs-poly of HOCl and OCl⁻ for 265 nm LED were found to be 1.50 and 0.70 mol E-1, respectively, whereas Φobs-poly of HOCl and OCl⁻ for 280 nm LED were 1.28 and 0.64 mol E-1, respectively. It was identified that Φobs-poly were 5.66-14.63 % lower than Φobs-mono. This suggests that obvious quantum yield using peak emission wavelength would overestimate the true quantum yield. The production of radical species in LED UV/chlorine systems were determined by the degradation of BA, and illustrated by a mathematical model. Different trends were observed for 265 nm and 280 nm LED UV/chlorine systems as pH increased from 5.0 to 10.0. As pH increased, the formation of OH continuously decreased in both 265 nm and 280 nm LED systems. The formation of Cl increased at neutral pH and more Cl and OH were formed due to the higher molar absorbance coefficient at 280 nm. The chlorine dose-dependent effects on radical productions at pH of 5.0, 7.5 and 10.0 were also assessed. At pH of 5.0, OH was the main radical product and had linear correlation with chlorine dose. At pH of 7.5, the productions of OH and Cl showed similar profiles that increased rapidly at low chlorine dosage and then slowed down.
Collapse
Affiliation(s)
- Guo-Qiang Li
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, 450001, PR China; Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Zheng-Yang Huo
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Qian-Yuan Wu
- Shenzhen Laboratory of Microorganism Application and Risk Control, Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, PR China
| | - Zhuo Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Yin-Hu Wu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Yun Lu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing, 100084, PR China
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), Beijing Laboratory for Environmental Frontier Technologies, School of Environment, Tsinghua University, Beijing, 100084, PR China; Research Institute for Environmental Innovation (Suzhou), Tsinghua, Suzhou, 215163, PR China.
| |
Collapse
|
11
|
Chen C, Guo L, Yang Y, Oguma K, Hou LA. Comparative effectiveness of membrane technologies and disinfection methods for virus elimination in water: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 801:149678. [PMID: 34416607 PMCID: PMC8364419 DOI: 10.1016/j.scitotenv.2021.149678] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 07/20/2021] [Accepted: 08/11/2021] [Indexed: 05/22/2023]
Abstract
The pandemic of the 2019 novel coronavirus disease (COVID-19) has brought viruses into the public horizon. Since viruses can pose a threat to human health in a low concentration range, seeking efficient virus removal methods has been the research hotspots in the past few years. Herein, a total of 1060 research papers were collected from the Web of Science database to identify technological trends as well as the research status. Based on the analysis results, this review elaborates on the state-of-the-art of membrane filtration and disinfection technologies for the treatment of virus-containing wastewater and drinking water. The results evince that membrane and disinfection methods achieve a broad range of virus removal efficiency (0.5-7 log reduction values (LRVs) and 0.09-8 LRVs, respectively) that is attributable to the various interactions between membranes or disinfectants and viruses having different susceptibility in viral capsid protein and nucleic acid. Moreover, this review discusses the related challenges and potential of membrane and disinfection technologies for customized virus removal in order to prevent the dissemination of the waterborne diseases.
Collapse
Affiliation(s)
- Chao Chen
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
| | - Lihui Guo
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
| | - Yu Yang
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
| | - Kumiko Oguma
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| | - Li-An Hou
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China; Xi'an High-Tech Institute, Xi'an 710025, China.
| |
Collapse
|
12
|
Preparation and bacteriostatic research of porous polyvinyl alcohol / biochar / nanosilver polymer gel for drinking water treatment. Sci Rep 2021; 11:12205. [PMID: 34108587 PMCID: PMC8190314 DOI: 10.1038/s41598-021-91833-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 04/27/2021] [Indexed: 11/29/2022] Open
Abstract
Microbial contamination in drinking water has become an important threat to human health. There is thus an urgent need to develop antibacterial materials to treat drinking water. Here, porous silver-loaded biochar (C–Ag) was prepared using corn straw as the substrate and silver as the antibacterial agent. C–Ag was then uniformly distributed in polyvinyl alcohol gel beads of eluted calcium carbonate to prepare p-PVA/C–Ag antibacterial composite. The polymer composites were tested by FT-IR, XRD, SEM and TG-DSC. The results showed that C–Ag was more evenly distributed in the PVA gel spheres. Antibacterial experiments showed that p-PVA/C–Ag greatly inhibited Escherichia coli. Practical application tests revealed that p-PVA/C–Ag showed high and sustained bactericidal inhibition and reusability. Generally, p-PVA/C–Ag composite shows high potential to be applied to drinking water treatment.
Collapse
|
13
|
Luo LW, Wu YH, Yu T, Wang YH, Chen GQ, Tong X, Bai Y, Xu C, Wang HB, Ikuno N, Hu HY. Evaluating method and potential risks of chlorine-resistant bacteria (CRB): A review. WATER RESEARCH 2021; 188:116474. [PMID: 33039832 DOI: 10.1016/j.watres.2020.116474] [Citation(s) in RCA: 84] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 09/07/2020] [Accepted: 09/27/2020] [Indexed: 05/21/2023]
Abstract
Chlorine-resistant bacteria (CRB) are commonly defined as bacteria with high resistance to chlorine disinfection or bacteria which can survive or even regrow in the residual chlorine. Chlorine disinfection cannot completely control the risks of CRB, such as risks of pathogenicity, antibiotic resistance and microbial growth. Currently, researchers pay more attention to CRB with pathogenicity or antibiotic resistance. The microbial growth risks of non-pathogenic CRB in water treatment and reclamation systems have been neglected to some extent. In this review, these three kinds of risks are all analyzed, and the last one is also highlighted. In order to study CRB, various methods are used to evaluate chlorine resistance. This review summarizes the evaluating methods for chlorine resistance reported in the literatures, and collects the important information about the typical isolated CRB strains including their genera, sources and levels of chlorine resistance. To our knowledge, few review papers have provided such systematic information about CRB. Among 44 typical CRB strains from 17 genera isolated by researchers, Mycobacterium, Bacillus, Legionella, Pseudomonas and Sphingomonas were the five genera with the highest frequency of occurrence in literatures. They are all pathogenic or opportunistic pathogenic bacteria. In addition, although there are many studies on CRB, information about chlorine resistance level is still limited to specie level or strain level. The difference in chlorine resistance level among different bacterial genera is less well understood. An inconvenient truth is that there is still no widely-accepted method to evaluate chlorine resistance and to identify CRB. Due to the lack of a unified method, it is difficult to compare the results about chlorine resistance level of bacterial strains in different literatures. A recommended evaluating method using logarithmic removal rate as an index and E. coli as a reference strain is proposed in this review based on the summary of the current evaluating methods. This method can provide common range of chlorine resistance of each genus and it is conducive to analyzing the distribution and abundance of CRB in the environment.
Collapse
Affiliation(s)
- Li-Wei Luo
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China
| | - Yin-Hu Wu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China.
| | - Tong Yu
- Qingdao University of Technology, Qingdao 266000, China
| | - Yun-Hong Wang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China
| | - Gen-Qiang Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China
| | - Xin Tong
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China
| | - Yuan Bai
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China
| | - Chuang Xu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China
| | - Hao-Bin Wang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China
| | - Nozomu Ikuno
- Kurita Water Industries Ltd., Nakano-ku, Tokyo 164-0001, Japan
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, China
| |
Collapse
|
14
|
Goswami KP, Pugazhenthi G. Credibility of polymeric and ceramic membrane filtration in the removal of bacteria and virus from water: A review. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2020; 268:110583. [PMID: 32383664 DOI: 10.1016/j.jenvman.2020.110583] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2020] [Revised: 03/27/2020] [Accepted: 04/07/2020] [Indexed: 05/24/2023]
Abstract
The prevalence of many waterborne diseases and the increased mortality rate starting from children to adult persons rises the need to purify water before consumption. Owing to the number of advantages associated with membrane filtration technologies, they are widely being implemented across the world for the production of pathogen free water. This article hence focuses on numerous such examples of using membrane technology in the production of drinking water. Membranes are even being coated with various materials to enhance their surface properties such as electrostatic and hydrophobic attraction capacity to aid for such separation. Various metal oxide coatings are seen to be gaining importance now-a-days and also, articles citing the use of silver coating are very large in number, owing to the excellent antipathogenic property shown by various silver compounds. It needs mention that examples have also been cited in this article where virus concentration was carried out with a purpose of producing different vaccines, virus adsorption in membrane and its subsequent elution (VIRADEL) being the most discussed one. In addition to these, description about the virus and bacteria quantification techniques are also mentioned in this article. The elaborated study of all these processes and the derived future prospects regarding the production of pathogen free water will certainly be helpful for the researchers working in this field, irrespective of the beginners or the experienced ones, to direct their research more innovatively.
Collapse
Affiliation(s)
- Kakali Priyam Goswami
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, 781039, Assam, India
| | - G Pugazhenthi
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, 781039, Assam, India.
| |
Collapse
|
15
|
Liu X, Hu JY. Effect of DNA sizes and reactive oxygen species on degradation of sulphonamide resistance sul1 genes by combined UV/free chlorine processes. JOURNAL OF HAZARDOUS MATERIALS 2020; 392:122283. [PMID: 32086093 DOI: 10.1016/j.jhazmat.2020.122283] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 01/24/2020] [Accepted: 02/10/2020] [Indexed: 06/10/2023]
Abstract
Nowadays, antibiotic resistance genes (ARGs) have been characterized as an emerging environmental contaminant, as the spread of ARGs may increase the difficulty of bacterial infection treatments. This study evaluates the combination of ultraviolet (UV) irradiation and chlorination, the two most commonly applied disinfection methods, on the degradation of sulphonamide resistance sul1 genes. The results revealed that although both of individual UV and chlorination processes were relatively less effective, two of the four combined processes, namely UV followed by chlorination (UV-Cl2) and simultaneous combination of UV and chlorination (UV/Cl2), delivered a better removal rate (up to 1.5 logs) with an observation of synergetic effects up to 0.609 log. The mechanisms analysis found that the difference of DNA size affected sul1 genes degradation by UV and chlorination; targeted genes on larger DNA fragments could be more effectively degraded by UV (1.09 logs for large fragments and 0.12 log for small fragments when UV dose reached 432 mJ/cm2), while to degrade ARGs on smaller DNA fragments required less free chlorine dosage (10 mg/L for small fragments and 40 mg/L for large fragments). The sequential combination of UV and chlorination (UV-Cl2) used the corresponding reactivity of both processes, which could be the reason for the synergetic effect. For UV/Cl2 process, the formation of reactive oxygen species (ROS) contributed to the synergetic effect. Scavenger analysis showed that the contribution of ROS to the sul1 gene reduction was 0.004 to 0.273 log (up to 45.5 % of the total synergy values), and among the two major reactive species in UV/Cl2 system, HO was the more important radical, while the contribution of Cl was negligible. Besides, UV/Cl2 process also used the corresponding reactivity of both processes to generate the remaining synergy values when excluding the contribution by reactive radicals. These findings provide a thorough understanding of the effects of UV and free chlorine on the degradation of ARGs and indicate the potential to utilize the combined processes of UV and free chlorine in water or wastewater treatment practice to control the dissemination of antibiotic resistance.
Collapse
Affiliation(s)
- Xiaochen Liu
- Department of Civil and Environmental Engineering, National University of Singapore, 117576, Singapore
| | - Jiang Yong Hu
- Department of Civil and Environmental Engineering, National University of Singapore, 117576, Singapore.
| |
Collapse
|
16
|
Jia S, Jia R, Zhang K, Sun S, Lu N, Wang M, Zhao Q. Disinfection characteristics of Pseudomonas peli, a chlorine-resistant bacterium isolated from a water supply network. ENVIRONMENTAL RESEARCH 2020; 185:109417. [PMID: 32247906 DOI: 10.1016/j.envres.2020.109417] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Revised: 03/15/2020] [Accepted: 03/20/2020] [Indexed: 06/11/2023]
Abstract
Lack of microbial contamination is crucial for drinking water quality and safety. Chlorine-resistant bacteria in drinking water distribution systems pose a threat to drinking water quality. A bacterium was isolated from an urban water supply network in northern China and identified as Pseudomonas peli by 16S rDNA gene analysis. This P. peli strain had high chlorine tolerance. The CT value (the product of disinfectant concentration and contact time) to achieve 3 lg unit (i.e. 99.9%)-inactivation of this P. peli isolate was 51.26-90.36 mg min/L, inversely proportional to the free chlorine concentration. Chlorine dioxide could inactivate the bacterium faster and more efficiently than free chlorine, as shown by flow cytometry. Thiazole orange plus propidium iodide staining indicated that free chlorine and chlorine dioxide inactivated P. peli primarily by disrupting the integrity and permeability of the cell membrane. The P. peli was also sensitive to ultraviolet (UV) radiation; a UV dose of 40 mJ/cm2 achieved 4 lg unit (99.99%)-inactivation. The Hom model was more suitable for analyzing the disinfection kinetics of P. peli than the Chick and Chick-Watson models.
Collapse
Affiliation(s)
- Shuyu Jia
- Shandong Province Water Supply and Drainage Monitoring Center, Jinan, 250000, China; College of Environmental Science and Engineering, Shandong Jianzhu University, Jinan, 250101, China
| | - Ruibao Jia
- Shandong Province Water Supply and Drainage Monitoring Center, Jinan, 250000, China.
| | - Kefeng Zhang
- College of Environmental Science and Engineering, Shandong Jianzhu University, Jinan, 250101, China
| | - Shaohua Sun
- Shandong Province Water Supply and Drainage Monitoring Center, Jinan, 250000, China
| | - Nannan Lu
- Shandong Province Water Supply and Drainage Monitoring Center, Jinan, 250000, China
| | - Mingquan Wang
- Shandong Province Water Supply and Drainage Monitoring Center, Jinan, 250000, China
| | - Qinghua Zhao
- Shandong Province Water Supply and Drainage Monitoring Center, Jinan, 250000, China
| |
Collapse
|
17
|
Gu Y, Xiao F, Luo L, Zhou X, Zhou X, Li J, Li Z. Bacterial Disinfection by CuFe 2O 4 Nanoparticles Enhanced by NH 2OH: A Mechanistic Study. NANOMATERIALS (BASEL, SWITZERLAND) 2019; 10:E18. [PMID: 31861627 PMCID: PMC7022556 DOI: 10.3390/nano10010018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 12/14/2019] [Accepted: 12/16/2019] [Indexed: 12/16/2022]
Abstract
Many disinfection technologies have emerged recently in water treatment industry, which are designed to inactivate water pathogens with extraordinary efficiency and minimum side effects and costs. Current disinfection processes, including chlorination, ozonation, UV irradiation, and so on, have their inherent drawbacks, and have been proven ineffective under certain scenarios. Bacterial inactivation by noble metals has been traditionally used, and copper is an ideal candidate as a bactericidal agent owing to its high abundance and low cost. Building on previous findings, we explored the bactericidal efficiency of Cu(I) and attempted to develop it into a novel water disinfection platform. Nanosized copper ferrite was synthesized, and it was reduced by hydroxylamine to form surface bound Cu(I) species. Our results showed that the generated Cu(I) on copper ferrite surface could inactivate E. coli at a much higher efficiency than Cu(II) species. Elevated reactive oxygen species' content inside the cell primarily accounted for the strong bactericidal role of Cu(I), which may eventually lead to enhanced oxidative stress towards cell membrane, DNA, and functional proteins. The developed platform in this study is promising to be integrated into current water treatment industry.
Collapse
Affiliation(s)
- Yu Gu
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Furen Xiao
- College of Materials Science and Engineering and State Key Laboratory of Metastable Materials Science and Technology, Yanshan University, Qinhuangdao 066004, China;
| | - Liumin Luo
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Xiaoyu Zhou
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Xiaodong Zhou
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Jin Li
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Zhi Li
- California State University San Bernardino, 5500 University Pkwy, San Bernardino, CA 92407, USA;
| |
Collapse
|
18
|
Bing S, Zang YT, Li YJ, Shu DQ. The synergistic effects of slightly acidic electrolyzed water and UV-C light on the inactivation of Salmonella enteritidis on contaminated eggshells. Poult Sci 2019; 98:6914-6920. [PMID: 31392328 PMCID: PMC8913955 DOI: 10.3382/ps/pez454] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 07/25/2019] [Indexed: 12/02/2022] Open
Abstract
Salmonella enteritidis (S. enteritidis) infection has been recognized as one of the most common bacterial causes of human gastroenteritis worldwide and is closely associated with eggs. Slightly acidic electrolyzed water (SAEW) is an emerging environmentally friendly technology for disinfecting eggshell surfaces to remove dirt and pathogenic microorganisms. However, the efficiency of SAEW could be affected by the presence of manure. UV-based advanced oxidation processes have been studied to improve the microorganism's inactivation effect of disinfection. Therefore, in this study, the synergistic bactericidal efficacy of SAEW and UV-C light (ultraviolet lamp, λ = 254 nm) for inactivation of S. enteritidis on artificially inoculated eggshells with or without manure was evaluated, and the bactericidal efficacy of different combination treatments of SAEW and UV-C light was compared. Without manure interference, complete inactivation (reduction of 6.54 log10 CFU/g) of S. enteritidis on the surface of eggshells was achieved following a 4-min treatment with SAEW+UV at an available chlorine concentration (ACC) of 20 mg/L. In the presence of manure, a 3.02 log reduction was achieved following a 4-min treatment with SAEW+UV at an ACC of 30 mg/L. Simultaneous treatment with SAEW and UV light exhibits higher bactericidal activity for eggshells than other combination process methods with UV and SAEW. The results suggest that the combined treatment of SAEW+UV is a novel method to enhance the microbial safety of eggshells.
Collapse
Affiliation(s)
- Sh Bing
- Jiangxi Agricultural University, Jiangxi 330045, China
| | - Y T Zang
- Jiangxi Agricultural University, Jiangxi 330045, China
| | - Y J Li
- Jiangxi Agricultural University, Jiangxi 330045, China
| | - D Q Shu
- Jiangxi Agricultural University, Jiangxi 330045, China
| |
Collapse
|
19
|
Chen L, Pinto A, Alshawabkeh AN. Activated Carbon as a Cathode for Water Disinfection through the Electro-Fenton Process. Catalysts 2019; 9:601. [PMID: 32154035 PMCID: PMC7062377 DOI: 10.3390/catal9070601] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Unlike many other water disinfection methods, hydroxyl radicals (HO•) produced by the Fenton reaction (Fe2+/H2O2) can inactivate pathogens regardless of taxonomic identity of genetic potential and do not generate halogenated disinfection by-products. Hydrogen peroxide (H2O2) required for the process is typically electrogenerated using various carbonaceous materials as cathodes. However, high costs and necessary modifications to the cathodes still present a challenge to large-scale implementation. In this work, we use granular activated carbon (GAC) as a cathode to generate H2O2 for water disinfection through the electro-Fenton process. GAC is a low-cost amorphous carbon with abundant oxygen- and carbon-containing groups that are favored for oxygen reduction into H2O2. Results indicate that H2O2 production at the GAC cathode is higher with more GAC, lower pH, and smaller reactor volume. Through the addition of iron ions, the electrogenerated H2O2 is transformed into HO• that efficiently inactivated model pathogen (Escherichia coli) under various water chemistry conditions. Chick-Watson modeling results further showed the strong lethality of produced HO• from the electro-Fenton process. This inactivation coupled with high H2O2 yield, excellent reusability, and relatively low cost of GAC proves that GAC is a promising cathodic material for large-scale water disinfection.
Collapse
Affiliation(s)
- Long Chen
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA 02115, USA
| | - Ameet Pinto
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA 02115, USA
| | - Akram N. Alshawabkeh
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA 02115, USA
| |
Collapse
|
20
|
Sommer J, Trautner C, Witte AK, Fister S, Schoder D, Rossmanith P, Mester PJ. Don't Shut the Stable Door after the Phage Has Bolted-The Importance of Bacteriophage Inactivation in Food Environments. Viruses 2019; 11:E468. [PMID: 31121941 PMCID: PMC6563225 DOI: 10.3390/v11050468] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 05/05/2019] [Accepted: 05/17/2019] [Indexed: 12/11/2022] Open
Abstract
In recent years, a new potential measure against foodborne pathogenic bacteria was rediscovered-bacteriophages. However, despite all their advantages, in connection to their widespread application in the food industry, negative consequences such as an uncontrolled phage spread as well as a development of phage resistant bacteria can occur. These problems are mostly a result of long-term persistence of phages in the food production environment. As this topic has been neglected so far, this article reviews the current knowledge regarding the effectiveness of disinfectant strategies for phage inactivation and removal. For this purpose, the main commercial phage products, as well as their application fields are first discussed in terms of applicable inactivation strategies and legal regulations. Secondly, an overview of the effectiveness of disinfectants for bacteriophage inactivation in general and commercial phages in particular is given. Finally, this review outlines a possible strategy for users of commercial phage products in order to improve the effectiveness of phage inactivation and removal after application.
Collapse
Affiliation(s)
- Julia Sommer
- Christian Doppler Laboratory for Monitoring of Microbial Contaminants, Department for Farm Animal and Public Health in Veterinary Medicine, University of Veterinary Medicine, Veterinaerplatz 1, 1210 Vienna, Austria.
| | - Christoph Trautner
- Christian Doppler Laboratory for Monitoring of Microbial Contaminants, Department for Farm Animal and Public Health in Veterinary Medicine, University of Veterinary Medicine, Veterinaerplatz 1, 1210 Vienna, Austria.
| | - Anna Kristina Witte
- Christian Doppler Laboratory for Monitoring of Microbial Contaminants, Department for Farm Animal and Public Health in Veterinary Medicine, University of Veterinary Medicine, Veterinaerplatz 1, 1210 Vienna, Austria.
- HTK Hygiene Technologie Kompetenzzentrum GmbH, Buger Str. 80, 96049 Bamberg, Germany.
| | - Susanne Fister
- Former member of Christian Doppler Laboratory for Monitoring of Microbial Contaminants, Institute of Milk Hygiene, Milk Technology and Food Science, Department for Farm Animal and Public Veterinary Health, University of Veterinary Medicine, Veterinärplatz 1, 1210 Vienna, Austria.
| | - Dagmar Schoder
- Unit of Food Microbiology, Institute of Food Safety, Food Technology and Veterinary Public Health, Department for Farm Animal and Public Health in Veterinary Medicine, University of Veterinary Medicine, Veterinaerplatz 1, 1210 Vienna, Austria.
| | - Peter Rossmanith
- Christian Doppler Laboratory for Monitoring of Microbial Contaminants, Department for Farm Animal and Public Health in Veterinary Medicine, University of Veterinary Medicine, Veterinaerplatz 1, 1210 Vienna, Austria.
- Unit of Food Microbiology, Institute of Food Safety, Food Technology and Veterinary Public Health, Department for Farm Animal and Public Health in Veterinary Medicine, University of Veterinary Medicine, Veterinaerplatz 1, 1210 Vienna, Austria.
| | - Patrick-Julian Mester
- Christian Doppler Laboratory for Monitoring of Microbial Contaminants, Department for Farm Animal and Public Health in Veterinary Medicine, University of Veterinary Medicine, Veterinaerplatz 1, 1210 Vienna, Austria.
| |
Collapse
|
21
|
Chang F, Shen S, Shi P, Zhang H, Ye L, Zhou Q, Pan Y, Li A. Antimicrobial resins with quaternary ammonium salts as a supplement to combat the antibiotic resistome in drinking water treatment plants. CHEMOSPHERE 2019; 221:132-140. [PMID: 30639809 DOI: 10.1016/j.chemosphere.2019.01.047] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 12/14/2018] [Accepted: 01/06/2019] [Indexed: 06/09/2023]
Abstract
The increasing finding of pathogens and antibiotic resistance genes (ARGs) in drinking water has become one of the most challenging global health threats worldwide. However, conventional disinfection strategies in drinking water treatment plants (DWTPs) require further optimization in combating the antibiotic resistome. Here, we show that antimicrobial resins with quaternary ammonium salts (AMRs-QAS) exhibit great potentials in diminishing specific potential pathogens that relatively resist chlorine or UV disinfection in DWTPs, and comprehensive analyses using microscopy and fluorescence techniques revealed that the antimicrobial capacity of AMRs-QAS mainly proceed via the bacterial adsorption and cell membrane dissociation. Moreover, a total of 15 among 30 selected ARGs, as well as 4 selected potential pathogens including Pseudomonas aeruginosa, Bacillus subtilis, Escherichia coli and Staphylococcus aureus were all detected in the source water. Coupling the AMRs-QAS with 0.2 mg/L chlorine resulted in higher removal efficiencies than chlorination (2 mg/L) or UV disinfection (400 mJ cm-2) for all the detected pathogens and ARGs in drinking water and significantly decreased the relative abundances of Pseudomonas aeruginosa, Bacillus subtilis, Escherichia coli, as well as all the detected ARGs (p < 0.05). Co-occurrences of pathogens and ARGs were revealed by a correlation network and possibly accounts for the ARGs removal. This coupled disinfection strategy overcomes the limitations of individual disinfection methods, i.e. the enrichment of specific pathogens and ARGs among bacterial populations, and provides an alternative for minimizing health risks induced by the antibiotic resistome in DWTPs.
Collapse
Affiliation(s)
- Fangyu Chang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Shanqi Shen
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Peng Shi
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
| | - Huaicheng Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Lin Ye
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Qing Zhou
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Yang Pan
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Aimin Li
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| |
Collapse
|
22
|
Shoults DC, Ashbolt NJ. Decreased efficacy of UV inactivation of Staphylococcus aureus after multiple exposure and growth cycles. Int J Hyg Environ Health 2019; 222:111-116. [DOI: 10.1016/j.ijheh.2018.08.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 08/14/2018] [Accepted: 08/14/2018] [Indexed: 10/28/2022]
|
23
|
Lian Y, Mai L, Cromar N, Buchanan N, Fallowfield H, Li X. MS2 coliphage and E. coli UVB inactivation rates in optically clear water: dose, dose rate and temperature dependence. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2018; 78:2228-2238. [PMID: 30629550 DOI: 10.2166/wst.2018.509] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Natural ultraviolet irradiance disinfection is known to play a significant role in both natural wastewater treatment systems and drinking water disinfection processes, while the influence of ultraviolet B (UVB) delivering method on sunlight disinfection outcome is still unclear. This study aims to determine the effects of environmentally relevant temperatures, UVB doses (J m-2) and dose rates (W m-2) on the inactivation and log reduction values (LRVs) of the F-RNA coliphage MS2 and Escherichia coli in optically clear water. E. coli and MS2 were separately incubated and irradiated at five different doses of UVB light that delivered using six UVB dose rates. The results of the study demonstrate that the UVB dose delivering method (combination of dose rate and exposure time) influences inactivation and LRVs of E. coli and MS2 at all UVB doses investigated (up to seven-fold difference). Two phases were identified within the UVB dose rate, UVB inactivation or LRV curves for both organisms; a UVB dose rate limited inactivation phase and a dose rate saturation inactivation phase. The results contribute to a better understanding of UVB disinfection in the environment and natural wastewater treatment systems, potentially improving the design and operation of high rate algal ponds.
Collapse
Affiliation(s)
- Yu Lian
- Key Laboratory of Environmental Biology and Pollution Control, School of Environmental Science and Engineering, Hunan University, Changsha, Hunan Province 410082, China E-mail: ; Health and the Environment Group; School of the Environment, Flinders University, Adelaide, South Australia 5042, Australia
| | - Lei Mai
- Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 510632, China
| | - Nancy Cromar
- Health and the Environment Group; School of the Environment, Flinders University, Adelaide, South Australia 5042, Australia
| | - Neil Buchanan
- Health and the Environment Group; School of the Environment, Flinders University, Adelaide, South Australia 5042, Australia
| | - Howard Fallowfield
- Health and the Environment Group; School of the Environment, Flinders University, Adelaide, South Australia 5042, Australia
| | - Xiaoming Li
- Key Laboratory of Environmental Biology and Pollution Control, School of Environmental Science and Engineering, Hunan University, Changsha, Hunan Province 410082, China E-mail:
| |
Collapse
|
24
|
Shoults DC, Ashbolt NJ. Total staphylococci as performance surrogate for greywater treatment. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2018; 25:32894-32900. [PMID: 28462431 PMCID: PMC6245020 DOI: 10.1007/s11356-017-9050-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Accepted: 04/18/2017] [Indexed: 06/02/2023]
Abstract
Faecal indicator bacteria (FIB) are commonly used as water quality indicators; implying faecal contamination and therefore the potential presence of pathogenic enteric bacteria, viruses, and protozoa. Hence in wastewater treatment, the most commonly used treatment process measures (surrogates) are total coliforms, faecal coliforms, Escherichia coli (E. coli), and enterococci. However, greywater potentially contains skin pathogens unrelated to faecal load, and E. coli and other FIB may grow within greywater unrelated to pathogens. Overall, FIB occurs at fluctuating and relatively low concentrations compared to other endogenous greywater bacteria affecting their ability as surrogates for pathogen reduction. Therefore, unlike municipal sewage, FIB provides a very limited and unreliable log-reduction surrogate measure for on-site greywater treatment systems. Based on our recent metagenomic study of laundry greywater, skin-associated bacteria such as Staphylococcus, Corynebacterium, and Propionibacterium spp. dominate and may result in more consistent treatment surrogates than traditional FIB. Here, we investigated various Staphylococcus spp. as potential surrogates to reliably assay over 4-log10 reduction by the final-stage UV disinfection step commonly used for on-site greywater reuse, and compare them to various FIB/phage surrogates. A collimated UV beam was used to determine the efficacy of UV inactivation (255, 265 and 285 nm) against E. coli, Enterococcus faecalis, E. faecium, E. casseliflavus, Staphylococcus aureus, and S. epidermidis. Staphylococcus spp. was estimated by combining the bi-linear dose-response curves for S. aureus and S. epidermidis and was shown to be less resistant to UV irradiation than the other surrogates examined. Hence, a relative inactivation credit is suggested; whereas, the doses required to achieve a 4 and 5-log10 reduction of Staphylococcus spp. (13.0 and 20.9 mJ cm-2, respectively) were used to determine the relative inactivation of the other microorganisms investigated. The doses required to achieve a 4 and 5-log10 reduction of Staphylococcus spp. resulted in a log10 reduction of 1.4 and 4.1 for E. coli, 0.8 and 2.8 for E. faecalis, 0.8 and 3.6 for E. casseliflavus and 0.8 and 1.2 for MS2 coliphage, respectively. Given the concentration difference of Staphylococcus spp. and FIB (3 to 5-log10 higher), we propose the use of Staphylococcus spp. as a novel endogenous performance surrogate to demonstrate greywater treatment performance given its relatively high and consistent concentration and therefore ability to demonstrate over 5-log10 reductions.
Collapse
Affiliation(s)
- David C Shoults
- School of Public Health, University of Alberta, Room 3-57, South Academic Building, Edmonton, AB, T6E 2G7, Canada.
| | - Nicholas J Ashbolt
- School of Public Health, University of Alberta, Room 3-57, South Academic Building, Edmonton, AB, T6E 2G7, Canada
| |
Collapse
|
25
|
Li GQ, Huo ZY, Wu QY, Lu Y, Hu HY. Synergistic effect of combined UV-LED and chlorine treatment on Bacillus subtilis spore inactivation. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 639:1233-1240. [PMID: 29929290 DOI: 10.1016/j.scitotenv.2018.05.240] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Revised: 05/19/2018] [Accepted: 05/19/2018] [Indexed: 06/08/2023]
Abstract
An ultraviolet (UV)-based advanced oxidation process (AOP) for disinfecting water is introduced in this paper. This study aimed to evaluate the potential of UV light-emitting diodes (UV-LEDs)/chlorine AOP (UV/Cl2) for Bacillus subtilis spore inactivation. Chlorine was combined with 265 and 280 nm LEDs (UV265/Cl2, UV280/Cl2) and investigated. The addition of 4.0 mg/L of free chlorine at pH 7.0 in the presence of 125 mJ/cm2 of UV irradiation resulted in an additional 1.8-log reduction in UV265/Cl2 and 1.5-log reduction in UV280/Cl2. There was no observed enhancement in spore inactivation with the addition of a radical scavenger, t-BuOH, which indicated the role of •OH in the synergistic effect. To quantitatively evaluate the synergism, the primary treatment with UV/Cl2 was followed by further UV or Cl2 treatment. After UV/Cl2 pretreatment at different pH levels, the 265 and 280 nm LEDs treatment enhanced an approximate 0.4-0.5-log reduction compared to UV only, and Cl2 treatment enhanced an approximate 0.7-1.1-log reduction compared to Cl2 only. In addition, at pH 7.0, in UV265/Cl2-Cl2 and UV280/Cl2-Cl2, the inactivation rate constant k increased by approximately 2 and 1.5 times, respectively. The CT for the lag phases (CTlag) reduced to approximately 67 and 58%, respectively. Similar results were obtained at pH 7.5 and 8.0, and in the secondary effluent. The synergistic effect on spore inactivation suggested that the pathogen inactivation efficiency of sequential UV and chlorine disinfection processes, which are commonly applied, can be significantly enhanced by adding chlorine prior to UV treatment.
Collapse
Affiliation(s)
- Guo-Qiang Li
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Zheng-Yang Huo
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Qian-Yuan Wu
- Shenzhen Laboratory of Microorganism Application and Risk Control, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, PR China
| | - Yun Lu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China.
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, PR China.
| |
Collapse
|
26
|
Yousefzadeh S, Matin AR, Ahmadi E, Sabeti Z, Alimohammadi M, Aslani H, Nabizadeh R. Response surface methodology as a tool for modeling and optimization of Bacillus subtilis spores inactivation by UV/ nano-Fe 0 process for safe water production. Food Chem Toxicol 2018; 114:334-345. [DOI: 10.1016/j.fct.2018.02.045] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2017] [Revised: 02/13/2018] [Accepted: 02/20/2018] [Indexed: 11/27/2022]
|
27
|
|
28
|
The Effect of UV and Combined Chlorine/UV Treatment on Coliphages in Drinking Water Disinfection. WATER 2016. [DOI: 10.3390/w8040130] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|