Ceddia M, Romasco T, Marchioli G, Comuzzi L, Cipollina A, Piattelli A, Lamberti L, Di Pietro N, Trentadue B. Finite Element Analysis of Implant Stability Quotient (ISQ) and Bone Stresses for Implant Inclinations of 0°, 15°, and 20°. MATERIALS (BASEL, SWITZERLAND) 2025; 18:1625. [PMID: 40271905 PMCID: PMC11990274 DOI: 10.3390/ma18071625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2025] [Revised: 03/27/2025] [Accepted: 03/31/2025] [Indexed: 04/25/2025]
Abstract
This study aimed to utilize finite element analysis (FEA) to evaluate the primary stability of Cyroth dental implants (AoN Implants Srl, Grisignano di Zocco, Italy) under various biomechanical conditions, including different implant inclinations (0°, 15°, and 20°) and bone densities (D3 and D4). By comparing these results with those obtained from in vitro tests on polyurethane blocks, the study sought to determine whether FEA could provide stability information more quickly and efficiently than in vitro methods. The research involved correlating dental implant micro-mobility with the implant stability quotient (ISQ) using FEA to simulate the mechanical behavior of implants and the surrounding bone tissue. Additionally, the study assessed the error in ISQ value detection by comparing FEA results with in vitro tests on polyurethane blocks conducted under the same experimental conditions. Both the FEA simulations and in vitro experiments demonstrated similar trends in ISQ values. For the D3 bone block simulated by FEA, the difference from the in vitro test was only 1.27%, while for the D2 bone, the difference was 2.86%. The findings also indicated that ISQ increases with implant inclination and that bone quality significantly affects primary stability, with ISQ decreasing as bone density diminishes. Overall, this study showed that ISQ evaluation for dental implants can be effectively performed through FEA, particularly by examining micro-movements. The results indicated that FEA and in vitro polyurethane testing yielded comparable outcomes, with FEA providing a faster and more cost-effective means of assessing ISQ across various clinical scenarios compared to in vitro testing.
Collapse
Affiliation(s)
- Mario Ceddia
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy; (M.C.); (L.L.); (B.T.)
| | - Tea Romasco
- Department of Medical, Oral and Biotechnological Sciences, “G. d’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy; (T.R.); (G.M.)
- Center for Advanced Studies and Technologies (CAST), “G. d’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy
| | - Giulia Marchioli
- Department of Medical, Oral and Biotechnological Sciences, “G. d’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy; (T.R.); (G.M.)
- Center for Advanced Studies and Technologies (CAST), “G. d’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy
| | - Luca Comuzzi
- Independent Researcher, 31020 San Vendemiano, Italy;
| | | | - Adriano Piattelli
- School of Dentistry, Saint Camillus International University of Health and Medical Sciences, 00131 Rome, Italy;
- Facultad de Medicina, UCAM Universidad Católica San Antonio de Murcia, 30107 Murcia, Spain
| | - Luciano Lamberti
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy; (M.C.); (L.L.); (B.T.)
| | - Natalia Di Pietro
- Department of Medical, Oral and Biotechnological Sciences, “G. d’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy; (T.R.); (G.M.)
- Center for Advanced Studies and Technologies (CAST), “G. d’Annunzio” University of Chieti-Pescara, 66100 Chieti, Italy
| | - Bartolomeo Trentadue
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy; (M.C.); (L.L.); (B.T.)
| |
Collapse
|
2
|
Son YT, Son K, Cho H, Lee JM, Saleah SA, Hwang J, Lee J, Kim H, Jin MU, Kim J, Jeon M, Lee KB. Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model. J Adv Prosthodont 2025; 17:101-114. [PMID: 40351864 PMCID: PMC12059371 DOI: 10.4047/jap.2025.17.2.101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2024] [Revised: 03/10/2025] [Accepted: 04/09/2025] [Indexed: 05/14/2025] Open
Abstract
PURPOSE The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser. MATERIALS AND METHODS A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants' surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05). RESULTS No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05). CONCLUSION Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
Collapse
Affiliation(s)
- Young-Tak Son
- Department of Dental Science, Graduate School, Kyungpook National University, Daegu, Republic of Korea
| | - KeunBaDa Son
- Advanced Dental Device Development Institute, Kyungpook National University, Daegu, Republic of Korea
| | - Hoseong Cho
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu, Republic of Korea
| | - Jae-Mok Lee
- Department of Periodontology, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Sm Abu Saleah
- ICT Convergence Research Center, Kyungpook National University, Daegu, Republic of Korea
| | - JunHo Hwang
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu, Republic of Korea
| | - JongHoon Lee
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu, Republic of Korea
| | - HyunDeok Kim
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu, Republic of Korea
| | - Myoung-Uk Jin
- Department of Conservative Dentistry, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Jeehyun Kim
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu, Republic of Korea
| | - Mansik Jeon
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu, Republic of Korea
| | - Kyu-Bok Lee
- Advanced Dental Device Development Institute, Kyungpook National University, Daegu, Republic of Korea
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| |
Collapse
|
3
|
Mistry S, Bhowmick D, Nayek M, Das I, Mistry S, Maitra NJ, Rudra A. A two-step hydrothermal method for micro/nanotextured titanium implants and their integration outcomes in goat mandible. Nanomedicine (Lond) 2025; 20:53-62. [PMID: 39620269 DOI: 10.1080/17435889.2024.2435246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Accepted: 11/25/2024] [Indexed: 01/02/2025] Open
Abstract
BACKGROUND A crucial aspect of contemporary dental implant research is modifying implant microdesign to achieve early and robust osseointegration. This study describes a new facile subtraction approach for microdesign modification of titanium implants using akali-hydrothermal followed by ion-exchange reaction (AHIE) in a salt solution, and compares osseointegration performance to machined titanium alloy (negative control) implants. METHODS The morphology, wettability, and roughness of the implant surfaces were evaluated. Twenty-four cylinders (two types/side) were inserted into the right and left mandibles of six Bengal goats in opposite order. The implant-bone interface was examined at 8 and 16 weeks following implantation using radiography, micro-computed tomography, histology, and scanning electron microscopy. RESULTS After AHIE treatment, average surface roughness increased marginally (p > 0.05) due to predominantly micron-scale with random nano-scale alterations, whereas wettability improved substantially (p < 0.05). In addition to micro/nano-scale defects, the AHIE treatment produced few honeycomb-like surface patterns. The AHIE implants demonstrated early and direct bone to implant body contact, and achieved stronger bone fixation in vivo than machined implants. CONCLUSIONS Based on laboratory and in vivo data, we conclude that AHIE processing of titanium implants may be a promising technique for improving surface quality while assuring secure and effective osseointegration for dental implant.
Collapse
Affiliation(s)
- Surajit Mistry
- Department of Periodontics, Dr. R. Ahmed Dental College and Hospital, Kolkata, West Bengal, India
| | - Debarati Bhowmick
- Department of Periodontics, Dr. R. Ahmed Dental College and Hospital, Kolkata, West Bengal, India
| | - Moumita Nayek
- Department of Dentistry, Diamond Harbour Government Medical College & Hospital Diamond Harbour, South 24 Parganas, West Bengal, India
| | - Indrasri Das
- Department of Periodontics, Dr. R. Ahmed Dental College and Hospital, Kolkata, West Bengal, India
| | - Shuvojit Mistry
- Murshidabad Medical College and Hospital, Berhampore, Murshidabad, West Bengal, India
| | - Nilendu Jyoti Maitra
- Deputy Director of Research, Extension and Firms, West Bengal University of Animal & Fishery Sciences, Kolkata, West Bengal, India
| | - Argha Rudra
- Department of Periodontics, Dr. R. Ahmed Dental College and Hospital, Kolkata, West Bengal, India
| |
Collapse
|
4
|
Wang Y, Cao X, Shen Y, Zhong Q, Huang Y, Zhang Y, Huang Q, Xu C. Osteogenic effect of low-intensity pulsed ultrasound on peri-implant bone: A systematic review and meta-analysis. J Prosthodont Res 2024; 68:215-226. [PMID: 37518333 DOI: 10.2186/jpr.jpr_d_23_00068] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/01/2023]
Abstract
Purpose This study aimed to evaluate the effect of low-intensity pulsed ultrasound (LIPUS) on promoting osseointegration around dental implants.Study selection A comprehensive search was performed on two databases, including MEDLINE (PubMed) and Web of Science to identify relevant studies published before June 1, 2022. Randomized controlled trials that met the inclusion criteria were selected for the study. The year of publication, study design, animal species, number of animals, number of implants, implant position, implant size, intervention, follow-up time, bone volume ratio (BV/TV), bone-implant contact ratio (BIC), and implant removal torque value (RTV) measurements, including mean and SD, were extracted.Results Ten randomized trials were included in this meta-analysis. The results showed that LIPUS significantly promoted osteogenesis around dental implants. Furthermore, in animal models of pre-existing diseases such as osteoporosis and diabetes, LIPUS had the same effect. The included data were divided into subgroups to explore the effects of different follow-up time, acoustic intensities, and frequencies. Results showed that higher acoustic intensities and frequencies significantly improve the osteogenic effects of LIPUS. There was some degree of heterogeneity owing to bias in the included studies. More high-quality randomized controlled trials are necessary in the future.Conclusions LIPUS can promote bone healing around dental implants and is an attractive option for edentulous patients, especially those with pre-existing diseases. Further clinical trials on the use of LIPUS in implant dentistry are warranted. Furthermore, future studies must pay more attention to acoustic intensity and frequency.
Collapse
Affiliation(s)
- Yingying Wang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Ximeng Cao
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yingyi Shen
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Qi Zhong
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yujie Huang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yifan Zhang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Qingfeng Huang
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Chun Xu
- Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Stomatology, Shanghai Jiao Tong University, Shanghai, China
- National Center for Stomatology and National Clinical Research Center for Oral Diseases, Shanghai, China
- Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| |
Collapse
|
5
|
van den Braak MCT, Hoekstra JWM, Bronkhorst EM, Schols JGJH, Ongkosuwito EM, Meijer GJ, van den Beucken JJJP. The effect of surface roughening on the success of orthodontic mini-implants: A systematic review and meta-analysis. Am J Orthod Dentofacial Orthop 2024; 165:262-271.e3. [PMID: 38069923 DOI: 10.1016/j.ajodo.2023.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 11/01/2023] [Accepted: 11/01/2023] [Indexed: 03/01/2024]
Abstract
INTRODUCTION Orthodontic mini-implants are a widely accepted treatment modality in orthodontics; however, the failure rate is moderately high. Surface roughening is the golden standard in conventional oral implantology, and this may prove beneficial for orthodontic mini-implants as well. The objective of this systematic review is to assess the effect of surface roughening on the success rate of orthodontic mini-implants in both adolescent and adult patients undergoing orthodontic treatment. METHODS Randomized studies comparing the success of surface-roughened and smooth, machined-surface orthodontic mini-implants were included. A literature search was conducted for 6 electronic databases (Pubmed/Medline, Embase, Cochrane, CINAHL, Web of Science, and Scopus), Clinical trial registry (https://www. CLINICALTRIALS gov), and grey literature (Google Scholar). A manual search of the reference lists of included studies was performed. Two authors independently performed the screening, data extraction, risk of bias, and quality assessments. The risk of bias was assessed with the Cochrane risk-of-bias 2.0 Tool. Data were synthesized using a random effect model meta-analysis presented as a forest plot. The certainty in the body of evidence was assessed using the Grading of Recommendations Assessment, Development, and Evaluation tool. RESULTS A total of 4226 unique records were screened, and 6 of these were included in the quantitative analysis. Four additional articles were selected for a secondary outcome. A total of 364 orthodontic mini-implants were included in the primary outcome analysis. There was no statistically significant effect of surface roughening on the success of orthodontic mini-implants (odds ratio = 0.63 favoring roughened orthodontic mini-implants; 95% confidence interval, 0.35-1.14). The secondary outcome (ie, the overall failure rate of roughened orthodontic mini-implants) was 6% based on studies with high heterogeneity. Limitations of this study were the risk of bias, study imprecision, and possible publication bias, leading to a very low certainty in the body of evidence. CONCLUSIONS There is very low-quality evidence that there is no statistically significant effect of surface roughening on the success of orthodontic mini-implants in humans. The overall failure rate of surface-roughened orthodontic mini-implants was 6%. FUNDING No funding was received for this review. REGISTRATION This study was preregistered in the Prospective Register of Systematic Reviews (CRD42022371830).
Collapse
Affiliation(s)
- Matheus C T van den Braak
- Section of Orthodontics and Craniofacial Biology, Department of Dentistry, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands
| | - Jan Willem M Hoekstra
- Section of Orthodontics and Craniofacial Biology, Department of Dentistry, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands
| | - Ewald M Bronkhorst
- Department of Dentistry, Radboud University Nijmegen Medical Center Nijmegen, The Netherlands
| | - Jan G J H Schols
- Section of Orthodontics and Craniofacial Biology, Department of Dentistry, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands
| | - Edwin M Ongkosuwito
- Section of Orthodontics and Craniofacial Biology, Department of Dentistry, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands
| | - Gert J Meijer
- Department of Oral Maxillofacial Surgery, Radboud University Nijmegen Medical Center Nijmegen, The Netherlands
| | - Jeroen J J P van den Beucken
- Section of Regenerative Biomaterials, Department of Dentistry, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands.
| |
Collapse
|
6
|
Andersen OZ, Bellón B, Lamkaouchi M, Brunelli M, Wei Q, Procter P, Pippenger BE. Determining primary stability for adhesively stabilized dental implants. Clin Oral Investig 2023:10.1007/s00784-023-04990-8. [PMID: 37269339 DOI: 10.1007/s00784-023-04990-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 03/28/2023] [Indexed: 06/05/2023]
Abstract
OBJECTIVES To examine factors influencing the primary stability of dental implants when stabilized in over-sized osteotomies using a calcium phosphate-based adhesive cement was the objective. METHODS Using implant removal torque measurements as a surrogate for primary stability, we examined the influence of implant design features (diameter, surface area, and thread design), along with cement gap size and curing time, on the resulting primary implant stability. RESULTS Removal torque values scaled with implant surface area and increasing implant diameters. Cement gap size did not alter the median removal torque values; however, larger gaps were associated with an increased spread of the measured values. Among the removal torque values measured, all were found to be above 32 Ncm which is an insertion torque threshold value commonly recommended for immediate loading protocols. CONCLUSION The adhesive cement show potential for offering primary implant stability for different dental implant designs. In this study, the primary parameters influencing the measured removal torque values were the implant surface area and diameter. As the liquid cement prevents the use of insertion torque, considering the relationship between insertion and removal torque, removal torque can be considered a reliable surrogate for primary implant stability for bench and pre-clinical settings. CLINICAL RELEVANCE At present, the primary stability of dental implants is linked to the quality of the host bone, the drill protocol, and the specific implant design. The adhesive cement might find applications in future clinical settings for enhancing primary stability of implants under circumstances where this cannot be achieved conventionally.
Collapse
Affiliation(s)
- Ole Zoffmann Andersen
- Department of Periodontology, University of Bern, Frieburgstrasse 7, 3010, Bern, Switzerland
- Institut Straumann AG, Basel, Switzerland
| | - Benjamin Bellón
- Institut Straumann AG, Basel, Switzerland
- Faculty of Medicine and Health Technology, University of Tampere, Tampere, Finland
| | | | | | - Qiuju Wei
- Department of Periodontology, University of Bern, Frieburgstrasse 7, 3010, Bern, Switzerland
| | - Philip Procter
- Department of Materials Science and Engineering, Applied Materials Science University of Uppsala, Uppsala, Sweden
| | - Benjamin E Pippenger
- Department of Periodontology, University of Bern, Frieburgstrasse 7, 3010, Bern, Switzerland.
- Institut Straumann AG, Basel, Switzerland.
| |
Collapse
|
7
|
Razaghi P, Moradi Haghgou J, Khazaei S, Farhadian N, Fekrazad R, Gholami L. The Effect of Photobiomodulation Therapy on the Stability of Orthodontic Mini-implants in Human and Animal Studies: A Systematic Review and Meta-analysis. J Lasers Med Sci 2023; 13:e27. [PMID: 36743132 PMCID: PMC9841378 DOI: 10.34172/jlms.2022.27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Accepted: 04/05/2022] [Indexed: 11/22/2022]
Abstract
Introduction: The present study aimed to systematically explore available literature on the possible impact of photobiomodulation (PBM) therapy on the stability and success of orthodontic mini-implants. Methods: A comprehensive electronic search was conducted in PubMed, ISI Web of Science, Scopus, Cochrane and Embase databases for human and animal studies published until July 2021. Two independent researchers reviewed the studies based on specific eligibility criteria. Results: 15 studies were included in the systematic review after a comprehensive search. Ten studies were included in the meta-analysis. Four were human RCT studies that evaluated the stability with Preriotest. Three other human RCT studies and two animal studies had evaluated the Implant stability quotient (ISQ). Two human RCTs that had evaluated displacement of mini-implants were also analyzed. The analysis of Periotest stability results showed a positive effect of PBM on mini-implant stability at 30 and 60 days after implantation (P<0.05). In human studies using the ISQ method, a slight improvement was seen in the PBM groups; however, this was not statistically significant (CI=-1.92-2.70, SMD=0.39). In studies that examined the displacement of mini-implants, no statistically significant difference was observed between irradiated and non-irradiated groups (CI=-1.92-2.70, SMD=0.03). According to the results of animal studies, which had used the ISQ method, the use of laser was statistically effective in increasing the stability of mini-implants (SMD=1.43, CI=1.00-1.85). Conclusion: PBM therapy can be suggested as an adjunctive clinical method to improve the stability of mini-implant treatment. Further well-designed clinical studies can help establish evidence-based dosing and irradiation protocols.
Collapse
Affiliation(s)
- Parnian Razaghi
- Dental Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Janet Moradi Haghgou
- Department of Periodontology, School of Dentistry, Hamadan Dental Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Salman Khazaei
- Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Nasrin Farhadian
- Department of Orthodontics, School of Dentistry, Hamadan Dental Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Reza Fekrazad
- Radiation Sciences Research Center, Laser Research Center in Medical Sciences, AJA University of Medical Sciences, Tehran, Iran.,International Network for Photo Medicine and Photo Dynamic Therapy (INPMPDT), Universal Scientific Education and Research Network (USERN), Tehran, Iran
| | - Leila Gholami
- Department of Periodontology, School of Dentistry, Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
8
|
Chen S, Rittel D, Shemtov-Yona K. Probing the sensitivity of the resonant frequency analysis to the dental implant-bone condition: A numerical study. J Mech Behav Biomed Mater 2022; 128:105128. [DOI: 10.1016/j.jmbbm.2022.105128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 02/07/2022] [Accepted: 02/08/2022] [Indexed: 11/29/2022]
|
9
|
Hériveaux Y, Nguyen VH, Haïat G. Ultrasonic Evaluation of the Bone-Implant Interface. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:373-396. [DOI: 10.1007/978-3-030-91979-5_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
10
|
Fraulob M, Vayron R, Le Cann S, Lecuelle B, Hériveaux Y, Albini Lomami H, Flouzat Lachaniette CH, Haïat G. Quantitative ultrasound assessment of the influence of roughness and healing time on osseointegration phenomena. Sci Rep 2020; 10:21962. [PMID: 33319800 PMCID: PMC7738679 DOI: 10.1038/s41598-020-78806-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 11/23/2020] [Indexed: 12/04/2022] Open
Abstract
The evolution of bone tissue quantity and quality in contact with the surface of orthopedic and dental implants is a strong determinant of the surgical outcome but remains difficult to be assessed quantitatively. The aim of this study was to investigate the performance of a quantitative ultrasound (QUS) method to measure bone-implant interface (BII) properties. A dedicated animal model considering coin-shaped titanium implants with two levels of surface roughness (smooth, Sa = 0.49 µm and rough, Sa = 3.5 µm) allowed to work with a reproducible geometry and a planar interface. The implants were inserted in rabbit femurs and tibiae for 7 or 13 weeks. The ultrasonic response of the BII was measured ex vivo, leading to the determination of the 2-D spatial variations of bone in contact with the implant surface. Histological analysis was carried out to determine the bone-implant contact (BIC) ratio. The amplitude of the echo was significantly higher after 7 weeks of healing time compared to 13 weeks, for both smooth (p < 0.01) and rough (p < 0.05) implants. A negative correlation (R = − 0.63) was obtained between the ultrasonic response and the BIC. This QUS technique is more sensitive to changes of BII morphology compared to histological analyses.
Collapse
Affiliation(s)
- M Fraulob
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - R Vayron
- Laboratoire d'Automatique, de Mécanique et d'informatique Industrielles et Humaines, LAMIH UMR CNRS 8201, Université Polytechnique Hauts de France, 59300, Valenciennes, France
| | - S Le Cann
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - B Lecuelle
- Centre de Recherche BioMédicale, Ecole Nationale Vétérinaire d'Alfort, 7 Avenue du Général de Gaulle, 94700, Maisons-Alfort, France
| | - Y Hériveaux
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - H Albini Lomami
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - C H Flouzat Lachaniette
- INSERM U955, IMRB Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France.,Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France
| | - G Haïat
- MSME, CNRS UMR 8208, Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France.
| |
Collapse
|