1
|
Chu Kwan W, Partanen A, Narayanan U, Waspe AC, Drake JM. Biomechanical testing of ex vivo porcine tendons following high intensity focused ultrasound thermal ablation. PLoS One 2024; 19:e0302778. [PMID: 38713687 DOI: 10.1371/journal.pone.0302778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2024] [Accepted: 04/12/2024] [Indexed: 05/09/2024] Open
Abstract
INTRODUCTION Magnetic resonance-guided focused ultrasound (MRgFUS) has been demonstrated to be able to thermally ablate tendons with the aim to non-invasively disrupt tendon contractures in the clinical setting. However, the biomechanical changes of tendons permitting this disrupting is poorly understood. We aim to obtain a dose-dependent biomechanical response of tendons following magnetic resonance-guided focused ultrasound (MRgFUS) thermal ablation. METHODS Ex vivo porcine tendons (n = 72) were embedded in an agar phantom and randomly assigned to 12 groups based on MRgFUS treatment. The treatment time was 10, 20, or 30s, and the applied acoustic power was 25, 50, 75, or 100W. Following each MRgFUS treatment, tendons underwent biomechanical tensile testing on an Instron machine, which calculated stress-strain curves during tendon elongation. Rupture rate, maximum treatment temperature, Young's modulus and ultimate strength were analyzed for each treatment energy. RESULTS The study revealed a dose-dependent response, with tendons rupturing in over 50% of cases when energy delivery exceeded 1000J and 100% disruption at energy levels beyond 2000J. The achieved temperatures during MRgFUS were directly proportional to energy delivery. The highest recorded temperature was 56.8°C ± 9.34 (3000J), while the lowest recorded temperate was 18.6°C ± 0.6 (control). The Young's modulus was highest in the control group (47.3 MPa ± 6.5) and lowest in the 3000J group (13.2 MPa ± 5.9). There was no statistically significant difference in ultimate strength between treatment groups. CONCLUSION This study establishes crucial thresholds for reliable and repeatable disruption of tendons, laying the groundwork for future in vivo optimization. The findings prompt further exploration of MRgFUS as a non-invasive modality for tendon disruption, offering hope for improved outcomes in patients with musculotendinous contractures.
Collapse
Affiliation(s)
| | | | - Unni Narayanan
- The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Adam C Waspe
- The Hospital for Sick Children, Toronto, Ontario, Canada
| | - James M Drake
- The Hospital for Sick Children, Toronto, Ontario, Canada
| |
Collapse
|
2
|
Single collagen fibrils isolated from high stress and low stress tendons show differing susceptibility to enzymatic degradation by the interstitial collagenase matrix metalloproteinase-1 (MMP-1). Matrix Biol Plus 2023; 18:100129. [PMID: 36915648 PMCID: PMC10006499 DOI: 10.1016/j.mbplus.2023.100129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 02/10/2023] [Accepted: 02/20/2023] [Indexed: 02/25/2023] Open
Abstract
Bovine forelimb flexor and extensor tendons serve as a model for examining high stress, energy storing and low stress, positional tendons, respectively. Previous research has shown structural differences between the collagen fibrils of these tissues. The nanoscale collagen fibrils of flexor tendons are smaller in size, more heavily crosslinked, and respond differently to mechanical loading. Meanwhile, energy storing tendons undergo less collagen turnover compared to positional tendons and are more commonly injured. These observations raise the question of whether collagen fibril structure influences the collagen degradation processes necessary for remodelling. Atomic force microscopy was used to image dry collagen fibrils before and after 5-hour exposure to matrix metalloproteinase-1 (MMP-1) to detect changes in fibril size. Collagen fibrils from three tissue types were studied: bovine superficial digital flexor tendons, matched-pair bovine lateral digital extensor tendons, and rat tail tendons. Compared to control fibrils exposed only to buffer, a significant decrease in fibril cross-sectional area (CSA) following MMP-1 exposure was observed for bovine extensor and rat tail fibrils, with larger fibrils experiencing a greater magnitude of CSA decrease in both fibril types. Fibrils from bovine flexor tendons, on the other hand, showed no decrease in CSA when exposed to MMP-1. The result did not appear to be linked to the small size of flexor fibrils, as equivalently sized extensor fibrils were readily degraded by the enzyme. Increased proteolytic resistance of collagen fibrils from high stress tendons may help to explain the longevity of collagen within these tissues in vivo.
Collapse
|
3
|
Waugh CM, Mousavizadeh R, Lee J, Screen HRC, Scott A. Mild hypercholesterolemia impacts achilles sub-tendon mechanical properties in young rats. BMC Musculoskelet Disord 2023; 24:282. [PMID: 37046262 PMCID: PMC10091839 DOI: 10.1186/s12891-023-06375-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 03/27/2023] [Indexed: 04/14/2023] Open
Abstract
BACKGROUND Hypercholesterolemia is associated with tendon pathology, but the reasons underpinning this relationship are not well understood. Cholesterol can accumulate in the tendon non-collagenous matrix which may affect both global and local tissue mechanics. Changes to the local strain environment within tendon may have significant implications for mechanosensitive tenocytes. Here, we investigated the association between elevated blood cholesterol and presence of tendon lipids in the Achilles tendon. We expected lipids to be localised in the proteoglycan-rich inter-sub-tendon matrix (ISTM), therefore we also sought to examine the impact of this on the biomechanical and viscoelastic properties of the ISTM. METHODS The Achilles tendons of 32 young wild-type (SD) and 32 apolipoprotein E knock-out rats (ApoE-/-) were harvested at 15.6 ± 2.3 weeks of age. 32 specimens underwent histological examination to assess the distribution of lipids throughout sub-tendons and ISTM. The remaining specimens were prepared for biomechanical testing, where the ISTM between the gastrocnemius and soleus sub-tendons was subjected to shear load mechanical testing. A sub-set of tests were video recorded to enable a strain analysis. RESULTS ApoE-/- serum cholesterol was double that of SD rats (mean 2.25 vs. 1.10 mg/ml, p < 0.001) indicating a relatively mild hypercholesterolemia phenotype. Nonetheless, we found histological evidence of esterified lipids in the ISTM and unesterified lipids in the sub-tendons, although the location or intensity of staining was not appreciably different between rat strains. Despite a lack of observable histological differences in lipid content between groups, there were significant differences in the mechanical and viscoelastic behaviour of the Achilles sub-tendon matrix. CONCLUSION Even slightly elevated cholesterol may result in subtle changes to tendon biomechanical properties and hence injury risk. The young age of our cohort and the mild phenotype of our ApoE-/- rats are likely to have limited our findings and so we also conclude that the ApoE-/- rat model is not well suited for investigating the biomechanical impact of tendon xanthomas on Achilles sub-tendon function.
Collapse
Affiliation(s)
- Charlie M Waugh
- Dept. Physical Therapy, Faculty of Medicine, University of British Columbia, Vancouver BC, Canada.
- School of Engineering and Materials Science, Queen Mary, University of London, London, U.K..
| | - Rouhollah Mousavizadeh
- Dept. Physical Therapy, Faculty of Medicine, University of British Columbia, Vancouver BC, Canada
| | - Jenny Lee
- Dept. Physical Therapy, Faculty of Medicine, University of British Columbia, Vancouver BC, Canada
| | - Hazel R C Screen
- School of Engineering and Materials Science, Queen Mary, University of London, London, U.K
| | - Alexander Scott
- Dept. Physical Therapy, Faculty of Medicine, University of British Columbia, Vancouver BC, Canada
| |
Collapse
|
4
|
Peserico A, Barboni B, Russo V, Bernabò N, El Khatib M, Prencipe G, Cerveró-Varona A, Haidar-Montes AA, Faydaver M, Citeroni MR, Berardinelli P, Mauro A. Mammal comparative tendon biology: advances in regulatory mechanisms through a computational modeling. Front Vet Sci 2023; 10:1175346. [PMID: 37180059 PMCID: PMC10174257 DOI: 10.3389/fvets.2023.1175346] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 04/03/2023] [Indexed: 05/15/2023] Open
Abstract
There is high clinical demand for the resolution of tendinopathies, which affect mainly adult individuals and animals. Tendon damage resolution during the adult lifetime is not as effective as in earlier stages where complete restoration of tendon structure and property occurs. However, the molecular mechanisms underlying tendon regeneration remain unknown, limiting the development of targeted therapies. The research aim was to draw a comparative map of molecules that control tenogenesis and to exploit systems biology to model their signaling cascades and physiological paths. Using current literature data on molecular interactions in early tendon development, species-specific data collections were created. Then, computational analysis was used to construct Tendon NETworks in which information flow and molecular links were traced, prioritized, and enriched. Species-specific Tendon NETworks generated a data-driven computational framework based on three operative levels and a stage-dependent set of molecules and interactions (embryo-fetal or prepubertal) responsible, respectively, for signaling differentiation and morphogenesis, shaping tendon transcriptional program and downstream modeling of its fibrillogenesis toward a mature tissue. The computational network enrichment unveiled a more complex hierarchical organization of molecule interactions assigning a central role to neuro and endocrine axes which are novel and only partially explored systems for tenogenesis. Overall, this study emphasizes the value of system biology in linking the currently available disjointed molecular data, by establishing the direction and priority of signaling flows. Simultaneously, computational enrichment was critical in revealing new nodes and pathways to watch out for in promoting biomedical advances in tendon healing and developing targeted therapeutic strategies to improve current clinical interventions.
Collapse
|
5
|
Kalemba M, Ekiert-Radecka M, Wajdzik M, Mlyniec A. An in-House System for the Precise Measurement of Electrical Potentials and Mechanical Properties of Soft Tissues: Design and Validation Using Adult Mammalian Tendon Fascicle Bundles. MATERIALS 2022; 15:ma15134444. [PMID: 35806569 PMCID: PMC9267749 DOI: 10.3390/ma15134444] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 06/03/2022] [Accepted: 06/17/2022] [Indexed: 02/04/2023]
Abstract
Tissues, such as skin, bones, and tendons, exhibit a piezoelectric effect, which may be an important phenomenon in terms of tissue renewal and regeneration as well as the possibility of modifying their mechanical behavior. In this article, we present the design and development of an in-house system for the precise measurement of electrical potentials and mechanical properties of tendons. The system was validated using tendon fascicle bundles derived from positional as well as energy-storing tendons from various adult mammals (porcine, bovine, and deer samples). The presented system is able to capture changes in elastic and viscoelastic properties of tissue as well as its time–voltage response and, thus, may be used in a broad spectrum of future studies to uncover factors influencing piezoelectric phenomena in tendons. This, in turn, will help to optimize current methods used in physiotherapy and postoperative treatment for effective tendon recovery.
Collapse
Affiliation(s)
- Marek Kalemba
- Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Krakow, Poland; (M.K.); (M.E.-R.)
| | - Martyna Ekiert-Radecka
- Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Krakow, Poland; (M.K.); (M.E.-R.)
| | - Marek Wajdzik
- Faculty of Forestry, University of Agriculture, Al. 29-listopada 46, 31-425 Krakow, Poland;
| | - Andrzej Mlyniec
- Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Krakow, Poland; (M.K.); (M.E.-R.)
- Correspondence:
| |
Collapse
|
6
|
Mechanical Properties of Animal Tendons: A Review and Comparative Study for the Identification of the Most Suitable Human Tendon Surrogates. Processes (Basel) 2022. [DOI: 10.3390/pr10030485] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
The mechanical response of a tendon to load is strictly related to its complex and highly organized hierarchical structure, which ranges from the nano- to macroscale. In a broader context, the mechanical properties of tendons during tensile tests are affected by several distinct factors, due in part to tendon nature (anatomical site, age, training, injury, etc.) but also depending on the experimental setup and settings. This work aimed to present a systematic review of the mechanical properties of tendons reported in the scientific literature by considering different anatomical regions in humans and several animal species (horse, cow, swine, sheep, rabbit, dog, rat, mouse, and foal). This study was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) method. The literature research was conducted via Google Scholar, PubMed, PicoPolito (Politecnico di Torino’s online catalogue), and Science Direct. Sixty studies were selected and analyzed. The structural and mechanical properties described in different animal species were reported and summarized in tables. Only the results from studies reporting the strain rate parameter were considered for the comparison with human tendons, as they were deemed more reliable. Our findings showed similarities between animal and human tendons that should be considered in biomechanical evaluation. An additional analysis of the effects of different strain rates showed the influence of this parameter.
Collapse
|
7
|
Wagner FC, Reese S, Gerlach K, Böttcher P, Mülling CKW. Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy. BMC Vet Res 2021; 17:223. [PMID: 34172051 PMCID: PMC8229380 DOI: 10.1186/s12917-021-02914-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Accepted: 05/24/2021] [Indexed: 01/20/2023] Open
Abstract
Background Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min. Results A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance. Conclusion In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs. Supplementary Information The online version contains supplementary material available at 10.1186/s12917-021-02914-w.
Collapse
Affiliation(s)
- Franziska C Wagner
- Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 43, 04103, Leipzig, Germany.
| | - Sven Reese
- Chair of Anatomy, Histology and Embryology, Department of Veterinary Sciences, LMU Munich, Veterinärstraße 13, 80539, Munich, Germany
| | - Kerstin Gerlach
- Department for Horses, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 21, 04103, Leipzig, Germany
| | - Peter Böttcher
- Small Animal Clinic, Department of Veterinary Medicine, Freie Universität Berlin, Oertzenweg 19 b, 14163, Berlin, Germany
| | - Christoph K W Mülling
- Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 43, 04103, Leipzig, Germany
| |
Collapse
|
8
|
O'Brien C, Marr N, Thorpe C. Microdamage in the equine superficial digital flexor tendon. Equine Vet J 2021; 53:417-430. [PMID: 32772396 DOI: 10.1111/evj.13331] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 06/02/2020] [Accepted: 07/30/2020] [Indexed: 12/24/2022]
Abstract
The forelimb superficial digital flexor tendon (SDFT) is an energy-storing tendon that is highly susceptible to injury during activities such as galloping and jumping, such that it is one of the most commonly reported causes of lameness in the performance horse. This review outlines the biomechanical and biothermal effects of strain on the SDFT and how these contribute to the accumulation of microdamage. The effect of age-related alterations on strain response and subsequent injury risk is also considered. Given that tendon is a slowly healing and poorly regenerative tissue, prompt detection of early stages of pathology in vivo and timely adaptations to training protocols are likely to have a greater outcome than advances in treatment. Early screening tools and detection protocols could subsequently be of benefit in identifying subclinical signs of degeneration during the training programme. This provides an opportunity for preventative strategies to be implemented to minimise incidences of SDFT injury and reduce recovery periods in elite performance horses. Therefore, this review will focus on the modalities available to implement early screening and prevention protocols as opposed to methods to diagnose and treat injuries.
Collapse
Affiliation(s)
| | - Neil Marr
- Department of Comparative Biomedical Sciences, Royal Veterinary College, London, UK
| | - Chavaunne Thorpe
- Department of Comparative Biomedical Sciences, Royal Veterinary College, London, UK
| |
Collapse
|
9
|
Eekhoff JD, Steenbock H, Berke IM, Brinckmann J, Yanagisawa H, Wagenseil JE, Lake SP. Dysregulated assembly of elastic fibers in fibulin-5 knockout mice results in a tendon-specific increase in elastic modulus. J Mech Behav Biomed Mater 2021; 113:104134. [PMID: 33045519 PMCID: PMC8146012 DOI: 10.1016/j.jmbbm.2020.104134] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 09/29/2020] [Accepted: 10/04/2020] [Indexed: 12/15/2022]
Abstract
Elastic fiber assembly is coordinated in part by fibulin-5, a matricellular protein. When fibulin-5 is not available to guide elastogenesis, elastin forms into disconnected globules instead of the dense elastic fiber core found in healthy tissues. Despite the growing evidence for a significant role of elastic fibers in tendon mechanics and the clinical relevance to cutis laxa, a human disease which can be caused by a mutation in the gene encoding fibulin-5, it is unknown how malformed elastic fibers affect tendon function. Therefore, this study investigated the effects of dysregulated elastic fiber assembly in tendons from fibulin-5 knockout mice in comparison to wild-type controls. Due to evidence for a more prominent role of elastic fibers in tendons with higher functional demands, both the energy-storing Achilles tendon and the more positional tibialis anterior tendon were evaluated. The linear modulus of knockout Achilles tendons was increased compared to controls, yet there was no discernible change in mechanical properties of the tibialis anterior tendon across genotypes. Transmission electron microscopy confirmed the presence of malformed elastic fibers in knockout tendons while no other changes to tendon composition or structure were found. The mechanism behind the increase in linear modulus in fibulin-5 knockout Achilles tendons may be greater collagen engagement due to decreased regulation of strain-induced structural reorganization. These findings support the theory of a significant, functionally distinct role of elastic fibers in tendon mechanics.
Collapse
Affiliation(s)
- Jeremy D Eekhoff
- Department of Biomedical Engineering, Washington University in St. Louis, USA
| | - Heiko Steenbock
- Institute of Virology and Cell Biology, University of Lübeck, Germany
| | - Ian M Berke
- Department of Biomedical Engineering, Washington University in St. Louis, USA
| | - Jürgen Brinckmann
- Institute of Virology and Cell Biology, University of Lübeck, Germany; Department of Dermatology, University of Lübeck, Germany
| | - Hiromi Yanagisawa
- Life Science Center for Survival Dynamics, Tsukuba Advanced Research Alliance, University of Tsukuba, Japan
| | - Jessica E Wagenseil
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, USA
| | - Spencer P Lake
- Department of Biomedical Engineering, Washington University in St. Louis, USA; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, USA; Department of Orthopaedic Surgery, Washington University in St. Louis, USA.
| |
Collapse
|
10
|
Siadat SM, Zamboulis DE, Thorpe CT, Ruberti JW, Connizzo BK. Tendon Extracellular Matrix Assembly, Maintenance and Dysregulation Throughout Life. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1348:45-103. [PMID: 34807415 DOI: 10.1007/978-3-030-80614-9_3] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
In his Lissner Award medal lecture in 2000, Stephen Cowin asked the question: "How is a tissue built?" It is not a new question, but it remains as relevant today as it did when it was asked 20 years ago. In fact, research on the organization and development of tissue structure has been a primary focus of tendon and ligament research for over two centuries. The tendon extracellular matrix (ECM) is critical to overall tissue function; it gives the tissue its unique mechanical properties, exhibiting complex non-linear responses, viscoelasticity and flow mechanisms, excellent energy storage and fatigue resistance. This matrix also creates a unique microenvironment for resident cells, allowing cells to maintain their phenotype and translate mechanical and chemical signals into biological responses. Importantly, this architecture is constantly remodeled by local cell populations in response to changing biochemical (systemic and local disease or injury) and mechanical (exercise, disuse, and overuse) stimuli. Here, we review the current understanding of matrix remodeling throughout life, focusing on formation and assembly during the postnatal period, maintenance and homeostasis during adulthood, and changes to homeostasis in natural aging. We also discuss advances in model systems and novel tools for studying collagen and non-collagenous matrix remodeling throughout life, and finally conclude by identifying key questions that have yet to be answered.
Collapse
Affiliation(s)
| | - Danae E Zamboulis
- Institute of Life Course and Medical Sciences, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, UK
| | - Chavaunne T Thorpe
- Comparative Biomedical Sciences, The Royal Veterinary College, University of London, London, UK
| | - Jeffrey W Ruberti
- Department of Bioengineering, Northeastern University, Boston, MA, USA
| | - Brianne K Connizzo
- Department of Biomedical Engineering, Boston University, Boston, MA, USA.
| |
Collapse
|
11
|
Lin AH, Allan AN, Zitnay JL, Kessler JL, Yu SM, Weiss JA. Collagen denaturation is initiated upon tissue yield in both positional and energy-storing tendons. Acta Biomater 2020; 118:153-160. [PMID: 33035697 DOI: 10.1016/j.actbio.2020.09.056] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 09/04/2020] [Accepted: 09/30/2020] [Indexed: 12/12/2022]
Abstract
Tendons are collagenous soft tissues that transmit loads between muscles and bones. Depending on their anatomical function, tendons are classified as positional or energy-storing with differing biomechanical and biochemical properties. We recently demonstrated that during monotonic stretch of positional tendons, permanent denatured collagen begins accumulating upon departing the linear region of the stress-strain curve. However, it is unknown if this observation is true during mechanical overload of other types of tendons. Therefore, the purpose of this study was to investigate the onset of collagen denaturation relative to applied strain, and whether it differs between the two tendon types. Rat tail tendon (RTT) fascicles and rat flexor digitorum longus (FDL) tendons represented positional and energy-storing tendons, respectively. The samples were stretched to incremental levels of strain, then stained with fluorescently labeled collagen hybridizing peptides (CHPs); the CHP fluorescence was measured to quantify denatured collagen. Denatured collagen in both positional and energy-storing tendons began to increase at the yield strain, upon leaving the linear region of the stress-strain curve as the sample started to permanently deform. Despite significant differences between the two tendon types, it appears that collagen denaturation is initiated at tissue yield during monotonic stretch, and the fundamental mechanism of failure is the same for the two types of tendons. At tissue failure, positional tendons had double the percentage of denatured collagen compared to energy-storing tendons, with no difference between 0% control groups. These results help to elucidate the etiology of subfailure injury and rupture in functionally distinct tendons.
Collapse
Affiliation(s)
- Allen H Lin
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States
| | - Alexandra N Allan
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States
| | - Jared L Zitnay
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States
| | - Julian L Kessler
- Department of Biomedical Engineering, University of Utah, United States
| | - S Michael Yu
- Department of Biomedical Engineering, University of Utah, United States; Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, United States
| | - Jeffrey A Weiss
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States; Department of Orthopaedics, University of Utah, United States.
| |
Collapse
|
12
|
Li G, Zhang R, Han D, Pang H, Yu G, Cao Q, Wang C, Kong L, Chengjin W, Dong W, Li T, Li J. Forelimb joints contribute to locomotor performance in reindeer ( Rangifer tarandus) by maintaining stability and storing energy. PeerJ 2020; 8:e10278. [PMID: 33240627 PMCID: PMC7666566 DOI: 10.7717/peerj.10278] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Accepted: 10/09/2020] [Indexed: 12/16/2022] Open
Abstract
Reindeer (Rangifer tarandus) have lengthy seasonal migrations on land and their feet possess excellent locomotor characteristics that can adapt to complex terrains. In this study, the kinematics and vertical ground reaction force (GRF) of reindeer forelimb joints (interphalangeal joint b, metacarpophalangeal joint c, and wrist joint d) under walk, trot 1, and trot 2 were measured using a motion tracking system and Footscan pressure plates. Significant differences among different locomotor activities were observed in the joint angles, but not in changes of the joint angles (αb, αc, αd) during the stance phase. Peak vertical GRF increased as locomotor speed increased. Net joint moment, power, and work at the forelimb joints were calculated via inverse dynamics. The peak joint moment and net joint power related to the vertical GRF increased as locomotor speed increased. The feet absorbed and generated more energy at the joints. During different locomotor activities, the contribution of work of the forelimbs changed with both gait and speed. In the stance phase, the metacarpophalangeal joint absorbed more energy than the other two joints while trotting and thus performed better in elastic energy storage. The joint angles changed very little (∼5°) from 0 to 75% of the stance phase, which reflected the stability of reindeer wrist joints. Compared to typical ungulates, reindeer toe joints are more stable and the stability and energy storage of forelimb joints contribute to locomotor performance in reindeer.
Collapse
Affiliation(s)
- Guoyu Li
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Rui Zhang
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Dianlei Han
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Hao Pang
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Guolong Yu
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Qingqiu Cao
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Chen Wang
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Lingxi Kong
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Wang Chengjin
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Wenchao Dong
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Tao Li
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| | - Jianqiao Li
- Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, People's Republic of China
| |
Collapse
|
13
|
A histological study on the tendons at chiasma plantare in pes cavus. Morphologie 2020; 105:54-63. [PMID: 33129658 DOI: 10.1016/j.morpho.2020.09.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 09/22/2020] [Accepted: 09/23/2020] [Indexed: 11/21/2022]
Abstract
INTRODUCTION In the dysfunction of large muscles of the leg, tendon transfer surgery is found to be very helpful in restoring the normal function of these muscles. The tendons involved in the chiasma plantare play a major role in this regard. OBJECTIVE The present cadaveric study has been carried out in cadavers presenting pes cavus. MATERIAL AND METHODS Cadaveric feet presenting pes cavus were identified based on their foot prints. All these tendons and their interconnections were subjected to histological procedures. The sections of the tendons were stained with hematoxylin and eosin in order to identify the underlying pathologies in the tendons. RESULTS Various types of tendinous interconnections between the tendons of flexor digitorum longus and flexor hallucis longus were noted. The histological findings showed infiltration of lymphocytes in the tendon sheath indicating tenosynovitis and tendinitis. This could be attributed to the compression of the tendons. A few tendons were also stretched due to the skeletal framework of the foot in pes cavus. The bones along the medial longitudinal arch in pes cavus feet could tend to develop spurs or elongated tuberosity that could impinge on the tendons causing the tendons to stretch and elongate. CONCLUSION In harvesting the tendons for grafting, the surgeons must be aware about the pathologies involved, such as tendinitis or tenosynovitis, in order to reduce the time taken for the healing of the graft post-surgery. These variations and histological findings can sub-serve as an efficient guide for the restoration of non-functioning muscles of the lower limb.
Collapse
|
14
|
Hill JR, Eekhoff JD, Brophy RH, Lake SP. Elastic fibers in orthopedics: Form and function in tendons and ligaments, clinical implications, and future directions. J Orthop Res 2020; 38:2305-2317. [PMID: 32293749 PMCID: PMC7572591 DOI: 10.1002/jor.24695] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Revised: 03/21/2020] [Accepted: 04/11/2020] [Indexed: 02/04/2023]
Abstract
Elastic fibers are an essential component of the extracellular matrix of connective tissues. The focus of both clinical management and scientific investigation of elastic fiber disorders has centered on the cardiovascular manifestations due to their significant impact on morbidity and mortality. As such, the current understanding of the orthopedic conditions experienced by these patients is limited. The musculoskeletal implications of more subtle elastic fiber abnormalities, whether due to allelic variants or age-related tissue degeneration, are also not well understood. Recent advances have begun to uncover the effects of elastic fiber deficiency on tendon and ligament biomechanics; future research must further elucidate mechanisms governing the role of elastic fibers in these tissues. The identification of population-based genetic variations in elastic fibers will also be essential. Minoxidil administration, modulation of protein expression with micro-RNA molecules, and direct injection of recombinant elastic fiber precursors have demonstrated promise for therapeutic intervention, but further work is required prior to consideration for orthopedic clinical application. This review provides an overview of the role of elastic fibers in musculoskeletal tissue, summarizes current knowledge of the orthopedic manifestations of elastic fiber abnormalities, and identifies opportunities for future investigation and clinical application.
Collapse
Affiliation(s)
- J. Ryan Hill
- Department of Orthopaedic Surgery, Washington University in St. Louis, 425 S. Euclid Avenue, Suite 5505, St. Louis, MO 63110
| | - Jeremy D. Eekhoff
- Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130
| | - Robert H. Brophy
- Department of Orthopaedic Surgery, Washington University in St. Louis, 425 S. Euclid Avenue, Suite 5505, St. Louis, MO 63110
| | - Spencer P. Lake
- Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130,Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130
| |
Collapse
|
15
|
Zamboulis DE, Thorpe CT, Ashraf Kharaz Y, Birch HL, Screen HR, Clegg PD. Postnatal mechanical loading drives adaptation of tissues primarily through modulation of the non-collagenous matrix. eLife 2020; 9:58075. [PMID: 33063662 PMCID: PMC7593091 DOI: 10.7554/elife.58075] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Accepted: 10/12/2020] [Indexed: 02/06/2023] Open
Abstract
Mature connective tissues demonstrate highly specialised properties, remarkably adapted to meet their functional requirements. Tissue adaptation to environmental cues can occur throughout life and poor adaptation commonly results in injury. However, the temporal nature and drivers of functional adaptation remain undefined. Here, we explore functional adaptation and specialisation of mechanically loaded tissues using tendon; a simple aligned biological composite, in which the collagen (fascicle) and surrounding predominantly non-collagenous matrix (interfascicular matrix) can be interrogated independently. Using an equine model of late development, we report the first phase-specific analysis of biomechanical, structural, and compositional changes seen in functional adaptation, demonstrating adaptation occurs postnatally, following mechanical loading, and is almost exclusively localised to the non-collagenous interfascicular matrix. These novel data redefine adaptation in connective tissue, highlighting the fundamental importance of non-collagenous matrix and suggesting that regenerative medicine strategies should change focus from the fibrous to the non-collagenous matrix of tissue.
Collapse
Affiliation(s)
- Danae E Zamboulis
- Institute of Ageing and Chronic Disease, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, United Kingdom
| | - Chavaunne T Thorpe
- Comparative Biomedical Sciences, The Royal Veterinary College, Royal College Street, London, United Kingdom
| | - Yalda Ashraf Kharaz
- Institute of Ageing and Chronic Disease, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, United Kingdom
| | - Helen L Birch
- University College London, Department of Orthopaedics and Musculoskeletal Science, Stanmore Campus, Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Hazel Rc Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, United Kingdom
| | - Peter D Clegg
- Institute of Ageing and Chronic Disease, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, United Kingdom
| |
Collapse
|
16
|
Citeroni MR, Ciardulli MC, Russo V, Della Porta G, Mauro A, El Khatib M, Di Mattia M, Galesso D, Barbera C, Forsyth NR, Maffulli N, Barboni B. In Vitro Innovation of Tendon Tissue Engineering Strategies. Int J Mol Sci 2020; 21:E6726. [PMID: 32937830 PMCID: PMC7555358 DOI: 10.3390/ijms21186726] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 09/06/2020] [Accepted: 09/07/2020] [Indexed: 12/12/2022] Open
Abstract
Tendinopathy is the term used to refer to tendon disorders. Spontaneous adult tendon healing results in scar tissue formation and fibrosis with suboptimal biomechanical properties, often resulting in poor and painful mobility. The biomechanical properties of the tissue are negatively affected. Adult tendons have a limited natural healing capacity, and often respond poorly to current treatments that frequently are focused on exercise, drug delivery, and surgical procedures. Therefore, it is of great importance to identify key molecular and cellular processes involved in the progression of tendinopathies to develop effective therapeutic strategies and drive the tissue toward regeneration. To treat tendon diseases and support tendon regeneration, cell-based therapy as well as tissue engineering approaches are considered options, though none can yet be considered conclusive in their reproduction of a safe and successful long-term solution for full microarchitecture and biomechanical tissue recovery. In vitro differentiation techniques are not yet fully validated. This review aims to compare different available tendon in vitro differentiation strategies to clarify the state of art regarding the differentiation process.
Collapse
Affiliation(s)
- Maria Rita Citeroni
- Unit of Basic and Applied Biosciences, Faculty of Bioscience and Agro-Food and Environmental Technology, University of Teramo, 64100 Teramo, Italy; (V.R.); (A.M.); (M.E.K.); (M.D.M.); (B.B.)
| | - Maria Camilla Ciardulli
- Department of Medicine, Surgery and Dentistry, University of Salerno, Via S. Allende, 84081 Baronissi (SA), Italy; (M.C.C.); (G.D.P.); (N.M.)
| | - Valentina Russo
- Unit of Basic and Applied Biosciences, Faculty of Bioscience and Agro-Food and Environmental Technology, University of Teramo, 64100 Teramo, Italy; (V.R.); (A.M.); (M.E.K.); (M.D.M.); (B.B.)
| | - Giovanna Della Porta
- Department of Medicine, Surgery and Dentistry, University of Salerno, Via S. Allende, 84081 Baronissi (SA), Italy; (M.C.C.); (G.D.P.); (N.M.)
- Interdepartment Centre BIONAM, Università di Salerno, via Giovanni Paolo I, 84084 Fisciano (SA), Italy
| | - Annunziata Mauro
- Unit of Basic and Applied Biosciences, Faculty of Bioscience and Agro-Food and Environmental Technology, University of Teramo, 64100 Teramo, Italy; (V.R.); (A.M.); (M.E.K.); (M.D.M.); (B.B.)
| | - Mohammad El Khatib
- Unit of Basic and Applied Biosciences, Faculty of Bioscience and Agro-Food and Environmental Technology, University of Teramo, 64100 Teramo, Italy; (V.R.); (A.M.); (M.E.K.); (M.D.M.); (B.B.)
| | - Miriam Di Mattia
- Unit of Basic and Applied Biosciences, Faculty of Bioscience and Agro-Food and Environmental Technology, University of Teramo, 64100 Teramo, Italy; (V.R.); (A.M.); (M.E.K.); (M.D.M.); (B.B.)
| | - Devis Galesso
- Fidia Farmaceutici S.p.A., via Ponte della Fabbrica 3/A, 35031 Abano Terme (PD), Italy; (D.G.); (C.B.)
| | - Carlo Barbera
- Fidia Farmaceutici S.p.A., via Ponte della Fabbrica 3/A, 35031 Abano Terme (PD), Italy; (D.G.); (C.B.)
| | - Nicholas R. Forsyth
- Guy Hilton Research Centre, School of Pharmacy and Bioengineering, Keele University, Thornburrow Drive, Stoke on Trent ST4 7QB, UK;
| | - Nicola Maffulli
- Department of Medicine, Surgery and Dentistry, University of Salerno, Via S. Allende, 84081 Baronissi (SA), Italy; (M.C.C.); (G.D.P.); (N.M.)
- Department of Musculoskeletal Disorders, Faculty of Medicine and Surgery, University of Salerno, Via San Leonardo 1, 84131 Salerno, Italy
- Centre for Sports and Exercise Medicine, Barts and The London School of Medicine and Dentistry, Mile End Hospital, Queen Mary University of London, 275 Bancroft Road, London E1 4DG, UK
- School of Pharmacy and Bioengineering, Keele University School of Medicine, Thornburrow Drive, Stoke on Trent ST5 5BG, UK
| | - Barbara Barboni
- Unit of Basic and Applied Biosciences, Faculty of Bioscience and Agro-Food and Environmental Technology, University of Teramo, 64100 Teramo, Italy; (V.R.); (A.M.); (M.E.K.); (M.D.M.); (B.B.)
| |
Collapse
|
17
|
Durgam S, Singh B, Cole SL, Brokken MT, Stewart M. Quantitative Assessment of Tendon Hierarchical Structure by Combined Second Harmonic Generation and Immunofluorescence Microscopy. Tissue Eng Part C Methods 2020; 26:253-262. [PMID: 32228165 DOI: 10.1089/ten.tec.2020.0032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Histological evaluation of healing tendons is primarily focused on monitoring restoration of longitudinal collagen alignment, although the elastic property of energy-storing flexor tendons is largely attributed to interfascicular sliding facilitated by the interfascicular matrix (IFM). The objectives of this study were to explore the utility of second harmonic generation (SHG) imaging to objectively assess cross-sectional tendon fascicle architecture, to combine SHG microscopy with elastin immunofluorescence to assess the ultrastructure of collagen and elastin in longitudinal and transverse sections, and lastly, to quantify changes in IFM elastin and fascicle collagen alignment of normal and collagenase-injured flexor tendons. Paraffin-embedded transverse and longitudinal histological sections (10-μm thickness) derived from normal and collagenase-injured (6- and 16-week time-points) equine superficial digital flexor tendons were de-paraffinized, treated with Tris EDTA at 80°C for epitope retrieval, and incubated with mouse monoclonal anti-elastin antibody (1:100 dilution) overnight. Anti-mouse IgG Alexa Flour 546 secondary antibody was applied, and sections were mounted with ProLong Gold reagent with 4',6-diamidino-2-phenylindole (DAPI). Nuclei (DAPI) and elastin (Alexa Fluor 546) signals were captured by using standard confocal imaging with 405 and 543 nm excitation wavelengths, respectively. The SHG signal was captured by using a tunable Ti:Sapphire laser tuned to 950 nm to visualize type I collagen. Quantitative measurements of fascicle cross-sectional area (CSA), IFM thickness in transverse SHG-DAPI merged z-stacks, fascicle/IFM elastin area fraction (%), and elastin-collagen alignment in longitudinal SHG-elastin merged z-stacks were conducted by using ImageJ software. Using this methodology, fascicle CSA, IFM thickness, and IFM elastin area fraction (%) at 6 weeks (∼2.25-fold; ∼2.8-fold; 60% decrease; p < 0.001) and 16 weeks (∼2-fold; ∼1.5-fold; 70% decrease; p < 0.001) after collagenase injection, respectively, were found to be significantly different from normal tendon. IFM elastin and fascicle collagen alignment characterized via fast Fourier transform (FFT) frequency plots at 16 weeks demonstrated that collagen re-alignment was more advanced than that of elastin. The integration of SHG-derived quantitative measurements in transverse and longitudinal tendon sections supports comprehensive assessment of tendon structure. Our findings demonstrate the importance of including IFM and non-collagenous proteins in tendon histological evaluations, tasks that can be effectively carried out by using SHG and immunofluorescence microscopy. Impact statement This work demonstrated that second harmonic generation microscopy in conjunction with elastin immunofluorescence provided a comprehensive assessment of multiscale structural re-organization in healing tendon than when restricted to longitudinal collagen fiber alignment alone. Utilizing this approach for tendon histomorphometry is ideal not only to improve our understanding of hierarchical structural changes that occur after tendon injury and during remodeling but also to monitor the efficacy of therapeutic approaches.
Collapse
Affiliation(s)
- Sushmitha Durgam
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, Ohio, USA
| | - Benjamin Singh
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, Ohio, USA
| | - Sara L Cole
- Campus Microscopy Imaging Facility, The Ohio State University, Columbus, Ohio, USA
| | - Matthew T Brokken
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, Ohio, USA
| | - Matthew Stewart
- Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois, Urbana, Illinois, USA
| |
Collapse
|
18
|
Choi RK, Smith MM, Smith S, Little CB, Clarke EC. Functionally distinct tendons have different biomechanical, biochemical and histological responses to in vitro unloading. J Biomech 2019; 95:109321. [DOI: 10.1016/j.jbiomech.2019.109321] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 08/02/2019] [Accepted: 08/15/2019] [Indexed: 01/29/2023]
|
19
|
Verkade ME, Back W, Birch HL. Equine digital tendons show breed-specific differences in their mechanical properties that may relate to athletic ability and predisposition to injury. Equine Vet J 2019; 52:320-325. [PMID: 31442314 DOI: 10.1111/evj.13169] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Accepted: 08/15/2019] [Indexed: 11/29/2022]
Abstract
BACKGROUND Throughout the ages, human subjects have selected horse breeds for their locomotor capacities. Concurrently, tissue properties may have diversified because of specific requirements of different disciplines. OBJECTIVES The aim of this study was to compare the biomechanical properties of tendons with different functions between equine breeds traditionally selected for racing or sport. STUDY DESIGN This study used ex vivo tendons and compared the mechanical properties of the common digital extensor tendon (CDET) and superficial digital flexor tendon (SDFT) between racehorses (Thoroughbred [TB]) and sports horses (Friesian Horse [FH], Warmblood [WB]). METHODS The SDFT and CDET of FH (n = 12), WBs (n = 12) and TBs (n = 8) aged 3-12 years were harvested. The cross sectional area (cm2 ), maximal load (N), ultimate strain (%), ultimate stress (MPa) and elastic modulus (MPa) were determined and tested for significant differences between the breeds (P<0.05). RESULTS The SDFT from WB horses had a significantly lower elastic modulus than TB horses and failed at a higher strain and load than both FHs and TBs. The mechanical properties of the CDET did not differ between breeds. In agreement with previous studies, the CDET failed at a higher stress and had a higher elastic modulus than the SDFT and, for the WB group of horses only, failed at a significantly lower strain. Interestingly, the mode of failure differed between breeds, particularly with respect to the FHs. MAIN LIMITATIONS The exercise history of horses used in this study was unknown and the age-range was relatively large; both these factors may have influenced the absolute properties reported in this study. CONCLUSIONS This study shows for the first time that mechanical properties of the SDFT differ between breeds. These properties are likely to be related to selection for high-speed vs. an extravagant elastic gait and may be an important indicator of performance ability. The Summary is available in Spanish - see Supporting Information.
Collapse
Affiliation(s)
- M E Verkade
- Department of Equine Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, the Netherlands
| | - W Back
- Department of Equine Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, the Netherlands.,Department of Surgery and Anaesthesiology, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - H L Birch
- Department of Orthopaedics and Musculoskeletal Science, University College London, London, UK
| |
Collapse
|
20
|
Hijazi KM, Singfield KL, Veres SP. Ultrastructural response of tendon to excessive level or duration of tensile load supports that collagen fibrils are mechanically continuous. J Mech Behav Biomed Mater 2019; 97:30-40. [DOI: 10.1016/j.jmbbm.2019.05.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 04/24/2019] [Accepted: 05/02/2019] [Indexed: 01/12/2023]
|
21
|
Obuchowicz R, Ekiert M, Kohut P, Holak K, Ambrozinski L, Tomaszewski K, Uhl T, Mlyniec A. Interfascicular matrix-mediated transverse deformation and sliding of discontinuous tendon subcomponents control the viscoelasticity and failure of tendons. J Mech Behav Biomed Mater 2019; 97:238-246. [DOI: 10.1016/j.jmbbm.2019.05.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 05/15/2019] [Accepted: 05/17/2019] [Indexed: 02/05/2023]
|
22
|
Hillin CD, Fryhofer GW, Freedman BR, Choi DS, Weiss SN, Huegel J, Soslowsky LJ. Effects of immobilization angle on tendon healing after achilles rupture in a rat model. J Orthop Res 2019; 37:562-573. [PMID: 30720208 PMCID: PMC6534419 DOI: 10.1002/jor.24241] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Accepted: 01/29/2019] [Indexed: 02/04/2023]
Abstract
Conservative (non-operative) treatment of Achilles tendon ruptures is a common alternative to operative treatment. Following rupture, ankle immobilization in plantarflexion is thought to aid healing by restoring tendon end-to-end apposition. However, early activity may improve limb function, challenging the role of immobilization position on tendon healing, as it may affect loading across the injury site. This study investigated the effects of ankle immobilization angle in a rat model of Achilles tendon rupture. We hypothesized that manipulating the ankle from full plantarflexion into a more dorsiflexed position during the immobilization period would result in superior hindlimb function and tendon properties, but that prolonged casting in dorsiflexion would result in inferior outcomes. After Achilles tendon transection, animals were randomized into eight immobilization groups ranging from full plantarflexion (160°) to mid-point (90°) to full dorsiflexion (20°), with or without angle manipulation. Tendon properties and ankle function were influenced by ankle immobilization position and time. Tendon lengthening occurred after 1 week at 20° compared to more plantarflexed angles, and was associated with loss of propulsion force. Dorsiflexing the ankle during immobilization from 160° to 90° produced a stiffer, more aligned tendon, but did not lead to functional changes compared to immobilization at 160°. Although more dorsiflexed immobilization can enhance tissue properties and function of healing Achilles tendon following rupture, full dorsiflexion creates significant tendon elongation regardless of application time. This study suggests that the use of moderate plantarflexion and earlier return to activity can provide improved clinical outcomes. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.
Collapse
Affiliation(s)
- Cody D. Hillin
- McKay Orthopaedic LaboratoryUniversity of Pennsylvania110 Stemmler Hall, 3450 Hamilton WalkPhiladelphiaPennsylvania19104‐6081
| | - George W. Fryhofer
- McKay Orthopaedic LaboratoryUniversity of Pennsylvania110 Stemmler Hall, 3450 Hamilton WalkPhiladelphiaPennsylvania19104‐6081
| | - Benjamin R. Freedman
- McKay Orthopaedic LaboratoryUniversity of Pennsylvania110 Stemmler Hall, 3450 Hamilton WalkPhiladelphiaPennsylvania19104‐6081
| | - Daniel S. Choi
- McKay Orthopaedic LaboratoryUniversity of Pennsylvania110 Stemmler Hall, 3450 Hamilton WalkPhiladelphiaPennsylvania19104‐6081
| | - Stephanie N. Weiss
- McKay Orthopaedic LaboratoryUniversity of Pennsylvania110 Stemmler Hall, 3450 Hamilton WalkPhiladelphiaPennsylvania19104‐6081
| | - Julianne Huegel
- McKay Orthopaedic LaboratoryUniversity of Pennsylvania110 Stemmler Hall, 3450 Hamilton WalkPhiladelphiaPennsylvania19104‐6081
| | - Louis J. Soslowsky
- McKay Orthopaedic LaboratoryUniversity of Pennsylvania110 Stemmler Hall, 3450 Hamilton WalkPhiladelphiaPennsylvania19104‐6081
| |
Collapse
|
23
|
Choi R, Smith M, Clarke E, Little C. Cellular, matrix, and mechano-biological differences in load-bearing versus positional tendons throughout development and aging: a narrative review. Connect Tissue Res 2018; 59:483-494. [PMID: 30231648 DOI: 10.1080/03008207.2018.1504929] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE Summarise available evidence comparing the cellular, biochemical, structural and biomechanical properties, and the changes that occur in these parameters in response to stimuli, in differentially loaded tendons across different stages of life. METHODS The PubMed database was searched for literature pertaining to differences between tendons using the term "tendon" or "tendinopathy", plus one or more of the following descriptors: "loading", "positional", "weight- or load-bearing", and "energy-storing". The abstracts were reviewed and relevant full-length articles retrieved and used to assemble a narrative review. RESULTS The incidence and prevalence of tendon disorders ("tendinopathies") is increasing in Western societies, with limited evidence that currently available treatments have any significant long-term effect on the disease course. A key emerging hypothesis is that disease in different tendons and even different regions within a tendon may be distinct. The available literature indicates that there are phenotypic differences, not only in the constitutive compositional and material properties but also in resident cells of positional compared with load-bearing tendons. Evident during early tendon growth, such differences have become well established by adulthood. CONCLUSIONS The pheno-endotype of tendinopathy may be distinct between load-bearing tendons compared to positional tendons, which has translational implications with regard to preventing and managing tendinopathy. Better understanding of the molecular, cellular, and biomechanical pathophysiology underlying disease phenotypes, will allow more targeted/personalised treatment and therefore improve outcomes.
Collapse
Affiliation(s)
- Rachel Choi
- a Raymond Purves Bone and Joint Research Laboratories, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia.,b Murray Maxwell Biomechanics Laboratory, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia
| | - Margaret Smith
- a Raymond Purves Bone and Joint Research Laboratories, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia
| | - Elizabeth Clarke
- b Murray Maxwell Biomechanics Laboratory, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia
| | - Christopher Little
- a Raymond Purves Bone and Joint Research Laboratories, Institute of Bone and Joint Research and Kolling Institute, Sydney Medical School , University of Sydney, at Royal North Shore Hospital , St Leonards , Australia
| |
Collapse
|
24
|
Quigley AS, Bancelin S, Deska-Gauthier D, Légaré F, Kreplak L, Veres SP. In tendons, differing physiological requirements lead to functionally distinct nanostructures. Sci Rep 2018. [PMID: 29535366 PMCID: PMC5849720 DOI: 10.1038/s41598-018-22741-8] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
The collagen-based tissues of animals are hierarchical structures: even tendon, the simplest collagenous tissue, has seven to eight levels of hierarchy. Tailoring tissue structure to match physiological function can occur at many different levels. We wanted to know if the control of tissue architecture to achieve function extends down to the nanoscale level of the individual, cable-like collagen fibrils. Using tendons from young adult bovine forelimbs, we performed stress-strain experiments on single collagen fibrils extracted from tendons with positional function, and tendons with energy storing function. Collagen fibrils from the two tendon types, which have known differences in intermolecular crosslinking, showed numerous differences in their responses to elongation. Unlike those from positional tendons, fibrils from energy storing tendons showed high strain stiffening and resistance to disruption in both molecular packing and conformation, helping to explain how these high stress tissues withstand millions of loading cycles with little reparative remodeling. Functional differences in load-bearing tissues are accompanied by important differences in nanoscale collagen fibril structure.
Collapse
Affiliation(s)
- Andrew S Quigley
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada
| | - Stéphane Bancelin
- Institut National de la Recherche Scientifique, Centre Énergie, Matériaux, Télécommunication, Varennes, Canada
| | | | - François Légaré
- Institut National de la Recherche Scientifique, Centre Énergie, Matériaux, Télécommunication, Varennes, Canada
| | - Laurent Kreplak
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada. .,School of Biomedical Engineering, Dalhousie University, Halifax, Canada.
| | - Samuel P Veres
- School of Biomedical Engineering, Dalhousie University, Halifax, Canada. .,Division of Engineering, Saint Mary's University, Halifax, Canada.
| |
Collapse
|
25
|
Herod TW, Veres SP. Development of overuse tendinopathy: A new descriptive model for the initiation of tendon damage during cyclic loading. J Orthop Res 2018; 36:467-476. [PMID: 28598009 DOI: 10.1002/jor.23629] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Accepted: 06/05/2017] [Indexed: 02/04/2023]
Abstract
Tendinopathic tissue has long been characterized by changes to collagen microstructure. However, initial tendon damage from excessive mechanical loading-a hallmark of tendinopathy development-could occur at the nanoscale level of collagen fibrils. Indeed, it is on this scale that tenocytes interact directly with tendon matrix, and excessive collagen fibril damage not visible at the microscale could trigger a degenerative cascade. In this study, we explored whether initiation of tendon damage during cyclic loading occurs via a longitudinal compression-induced buckling mechanism of collagen fibrils leading to nanoscale kinkband development. Two groups of tendons were cyclically loaded to equivalent peak stresses. In each loading cycle, tendons in one group were unloaded to the zero displacement mark, while those in the other group were unloaded to a nominal level of tension, minimizing the potential for fibril buckling. Tendons that were unloaded to the zero displacement mark ruptured significantly sooner during cyclic loading (1,446 ± 737 vs. 4,069 ± 1,129 cycles), indicating that significant fatigue damage is accrued in the low stress, toe region of the load-deformation response. Ultrastructural analysis using scanning electron microscopy of tendons stopped after 1,000 cycles showed that maintaining a nominal tension slowed the accumulation of kinkbands, supporting a longitudinal compression-induced buckling mechanism as the basis for kinkband development. Based on our results, we present a new descriptive model for the initiation of tendon damage during cyclic loading. The so-called Compression of Unrecovered Elongation or CUE Model may provide useful insight into the development of tendinopathy. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:467-476, 2018.
Collapse
Affiliation(s)
- Tyler W Herod
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Samuel P Veres
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada.,Division of Engineering, Saint Mary's University, 923 Robie Street, Halifax, Nova Scotia Canada B3H 3C3
| |
Collapse
|
26
|
Godinho MSC, Thorpe CT, Greenwald SE, Screen HRC. Elastin is Localised to the Interfascicular Matrix of Energy Storing Tendons and Becomes Increasingly Disorganised With Ageing. Sci Rep 2017; 7:9713. [PMID: 28855560 PMCID: PMC5577209 DOI: 10.1038/s41598-017-09995-4] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2017] [Accepted: 08/01/2017] [Indexed: 11/10/2022] Open
Abstract
Tendon is composed of fascicles bound together by the interfascicular matrix (IFM). Energy storing tendons are more elastic and extensible than positional tendons; behaviour provided by specialisation of the IFM to enable repeated interfascicular sliding and recoil. With ageing, the IFM becomes stiffer and less fatigue resistant, potentially explaining why older tendons become more injury-prone. Recent data indicates enrichment of elastin within the IFM, but this has yet to be quantified. We hypothesised that elastin is more prevalent in energy storing than positional tendons, and is mainly localised to the IFM. Further, we hypothesised that elastin becomes disorganised and fragmented, and decreases in amount with ageing, especially in energy storing tendons. Biochemical analyses and immunohistochemical techniques were used to determine elastin content and organisation, in young and old equine energy storing and positional tendons. Supporting the hypothesis, elastin localises to the IFM of energy storing tendons, reducing in quantity and becoming more disorganised with ageing. These changes may contribute to the increased injury risk in aged energy storing tendons. Full understanding of the processes leading to loss of elastin and its disorganisation with ageing may aid in the development of treatments to prevent age related tendinopathy.
Collapse
Affiliation(s)
- Marta S C Godinho
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, E1 4NS, United Kingdom
| | - Chavaunne T Thorpe
- Comparative Biomedical Sciences, The Royal Veterinary College, Royal College Street, London, NW1 0TU, United Kingdom
| | - Steve E Greenwald
- Blizard Institute, Barts and London School of Medicine and Dentistry, Turner Street, London, E1 11BB, United Kingdom
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, E1 4NS, United Kingdom.
| |
Collapse
|
27
|
Shearer T, Thorpe CT, Screen HRC. The relative compliance of energy-storing tendons may be due to the helical fibril arrangement of their fascicles. J R Soc Interface 2017; 14:20170261. [PMID: 28794162 PMCID: PMC5582123 DOI: 10.1098/rsif.2017.0261] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Accepted: 07/10/2017] [Indexed: 01/04/2023] Open
Abstract
A nonlinear elastic microstructural model is used to investigate the relationship between structure and function in energy-storing and positional tendons. The model is used to fit mechanical tension test data from the equine common digital extensor tendon (CDET) and superficial digital flexor tendon (SDFT), which are used as archetypes of positional and energy-storing tendons, respectively. The fibril crimp and fascicle helix angles of the two tendon types are used as fitting parameters in the mathematical model to predict their values. The outer fibril crimp angles were predicted to be 15.1° ± 2.3° in the CDET and 15.8° ± 4.1° in the SDFT, and the average crimp angles were predicted to be 10.0° ± 1.5° in the CDET and 10.5° ± 2.7° in the SDFT. The crimp angles were not found to be statistically significantly different between the two tendon types (p = 0.572). By contrast, the fascicle helix angles were predicted to be 7.9° ± 9.3° in the CDET and 29.1° ± 10.3° in the SDFT and were found to be statistically highly significantly different between the two tendon types (p < 0.001). This supports previous qualitative observations that helical substructures are more likely to be found in energy-storing tendons than in positional tendons and suggests that the relative compliance of energy-storing tendons may be directly caused by these helical substructures.
Collapse
Affiliation(s)
- Tom Shearer
- School of Mathematics, University of Manchester, Manchester M13 9PL, UK
| | - Chavaunne T Thorpe
- Department of Comparative Biomedical Sciences, The Royal Veterinary College, Royal College Street, London NW1 0TU, UK
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS, UK
| |
Collapse
|
28
|
Fascicles and the interfascicular matrix show decreased fatigue life with ageing in energy storing tendons. Acta Biomater 2017; 56:58-64. [PMID: 28323176 PMCID: PMC5486374 DOI: 10.1016/j.actbio.2017.03.024] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Revised: 02/09/2017] [Accepted: 03/14/2017] [Indexed: 12/27/2022]
Abstract
Tendon is composed of rope-like fascicles bound together by interfascicular matrix (IFM). The IFM is critical for the function of energy storing tendons, facilitating sliding between fascicles to allow these tendons to cyclically stretch and recoil. This capacity is required to a lesser degree in positional tendons. We have previously demonstrated that both fascicles and IFM in energy storing tendons have superior fatigue resistance compared with positional tendons, but the effect of ageing on the fatigue properties of these different tendon subunits has not been determined. Energy storing tendons become more injury-prone with ageing, indicating reduced fatigue resistance, hence we tested the hypothesis that the decline in fatigue life with ageing in energy storing tendons would be more pronounced in the IFM than in fascicles. We further hypothesised that tendon subunit fatigue resistance would not alter with ageing in positional tendons. Fascicles and IFM from young and old energy storing and positional tendons were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results show that both IFM and fascicles from the SDFT exhibit a similar magnitude of reduced fatigue life with ageing. By contrast, the fatigue life of positional tendon subunits was unaffected by ageing. The age-related decline in fatigue life of tendon subunits in energy storing tendons is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms resulting in this reduced fatigue life will aid in the development of treatments and interventions to prevent age-related tendinopathy. Statement of Significance Understanding the effect of ageing on tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for age-related tendon injury. In this study, we demonstrate for the first time that the fatigue resistance of the interfascicular matrix decreases with ageing in energy storing tendons. This is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms that result in this reduced fatigue resistance will aid in the development of treatments and interventions to prevent age-related tendinopathy.
Collapse
|
29
|
Geburek F, Roggel F, van Schie HTM, Beineke A, Estrada R, Weber K, Hellige M, Rohn K, Jagodzinski M, Welke B, Hurschler C, Conrad S, Skutella T, van de Lest C, van Weeren R, Stadler PM. Effect of single intralesional treatment of surgically induced equine superficial digital flexor tendon core lesions with adipose-derived mesenchymal stromal cells: a controlled experimental trial. Stem Cell Res Ther 2017; 8:129. [PMID: 28583184 PMCID: PMC5460527 DOI: 10.1186/s13287-017-0564-8] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Revised: 03/15/2017] [Accepted: 04/26/2017] [Indexed: 12/31/2022] Open
Abstract
Background Adipose tissue is a promising source of mesenchymal stromal cells (MSCs) for the treatment of tendon disease. The goal of this study was to assess the effect of a single intralesional implantation of adipose tissue-derived mesenchymal stromal cells (AT-MSCs) on artificial lesions in equine superficial digital flexor tendons (SDFTs). Methods During this randomized, controlled, blinded experimental study, either autologous cultured AT-MSCs suspended in autologous inactivated serum (AT-MSC-serum) or autologous inactivated serum (serum) were injected intralesionally 2 weeks after surgical creation of centrally located SDFT lesions in both forelimbs of nine horses. Healing was assessed clinically and with ultrasound (standard B-mode and ultrasound tissue characterization) at regular intervals over 24 weeks. After euthanasia of the horses the SDFTs were examined histologically, biochemically and by means of biomechanical testing. Results AT-MSC implantation did not substantially influence clinical and ultrasonographic parameters. Histology, biochemical and biomechanical characteristics of the repair tissue did not differ significantly between treatment modalities after 24 weeks. Compared with macroscopically normal tendon tissue, the content of the mature collagen crosslink hydroxylysylpyridinoline did not differ after AT-MSC-serum treatment (p = 0.074) while it was significantly lower (p = 0.027) in lesions treated with serum alone. Stress at failure (p = 0.048) and the modulus of elasticity (p = 0.001) were significantly lower after AT-MSC-serum treatment than in normal tendon tissue. Conclusions The effect of a single intralesional injection of cultured AT-MSCs suspended in autologous inactivated serum was not superior to treatment of surgically created SDFT lesions with autologous inactivated serum alone in a surgical model of tendinopathy over an observation period of 22 weeks. AT-MSC treatment might have a positive influence on collagen crosslinking of remodelling scar tissue. Controlled long-term studies including naturally occurring tendinopathies are necessary to verify the effects of AT-MSCs on tendon disease. Electronic supplementary material The online version of this article (doi:10.1186/s13287-017-0564-8) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Florian Geburek
- Equine Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559, Hannover, Germany.
| | - Florian Roggel
- Equine Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559, Hannover, Germany
| | - Hans T M van Schie
- Department of Equine Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 112, 3584 CM, Utrecht, The Netherlands
| | - Andreas Beineke
- Institute for Pathology, University of Veterinary Medicine Hannover, Foundation, Bünteweg 17, 30559, Hannover, Germany
| | - Roberto Estrada
- Department of Equine Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 112, 3584 CM, Utrecht, The Netherlands
| | - Kathrin Weber
- Pferdeklink Kirchheim, Nürtinger Straße 200, 73230, Kirchheim unter Teck, Germany
| | - Maren Hellige
- Equine Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559, Hannover, Germany
| | - Karl Rohn
- Institute for Biometry, Epidemiology and Information Processing, University of Veterinary Medicine Hannover, Foundation, Bünteweg 2, 30559, Hannover, Germany
| | - Michael Jagodzinski
- Department of Orthopedic Trauma, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany
| | - Bastian Welke
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany
| | - Christof Hurschler
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany
| | | | - Thomas Skutella
- Institute for Anatomy and Cell Biology, University of Heidelberg, Im Neuenheimer Feld 307, 69120, Heidelberg, Germany
| | - Chris van de Lest
- Department of Equine Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 112, 3584 CM, Utrecht, The Netherlands
| | - René van Weeren
- Department of Equine Sciences, Faculty of Veterinary Medicine, Utrecht University, Yalelaan 112, 3584 CM, Utrecht, The Netherlands
| | - Peter M Stadler
- Equine Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559, Hannover, Germany
| |
Collapse
|
30
|
Herod TW, Chambers NC, Veres SP. Collagen fibrils in functionally distinct tendons have differing structural responses to tendon rupture and fatigue loading. Acta Biomater 2016; 42:296-307. [PMID: 27321189 DOI: 10.1016/j.actbio.2016.06.017] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Revised: 06/03/2016] [Accepted: 06/10/2016] [Indexed: 12/24/2022]
Abstract
UNLABELLED In this study we investigate relationships between the nanoscale structure of collagen fibrils and the macroscale functional response of collagenous tissues. To do so, we study two functionally distinct classes of tendons, positional tendons and energy storing tendons, using a bovine forelimb model. Molecular-level assessment using differential scanning calorimetry (DSC), functional crosslink assessment using hydrothermal isometric tension (HIT) analysis, and ultrastructural assessment using scanning electron microscopy (SEM) were used to study undamaged, ruptured, and cyclically loaded samples from the two tendon types. HIT indicated differences in both crosslink type and crosslink density, with flexor tendons having more thermally stable crosslinks than the extensor tendons (higher TFmax of >90 vs. 75.1±2.7°C), and greater total crosslink density than the extensor tendons (higher t1/2 of 11.5±1.9 vs. 3.5±1.0h after NaBH4 treatment). Despite having a lower crosslink density than flexor tendons, extensor tendons were significantly stronger (37.6±8.1 vs. 23.1±7.7MPa) and tougher (14.3±3.6 vs. 6.8±3.4MJ/m(3)). SEM showed that collagen fibrils in the tougher, stronger extensor tendons were able to undergo remarkable levels of plastic deformation in the form of discrete plasticity, while those in the flexor tendons were not able to plastically deform. When cyclically loaded, collagen fibrils in extensor tendons accumulated fatigue damage rapidly in the form of kink bands, while those in flexor tendons did not accumulate significant fatigue damage. The results demonstrate that collagen fibrils in functionally distinct tendons respond differently to mechanical loading, and suggests that fibrillar collagens may be subject to a strength vs. fatigue resistance tradeoff. STATEMENT OF SIGNIFICANCE Collagen fibrils-nanoscale biological cables-are the fundamental load-bearing elements of all structural human tissues. While all collagen fibrils share common features, such as being composed of a precise quarter-staggered polymeric arrangement of triple-helical collagen molecules, their structure can vary significantly between tissue types, and even between different anatomical structures of the same tissue type. To understand normal function, homeostasis, and disease of collagenous tissues requires detailed knowledge of collagen fibril structure-function. Using anatomically proximate but structurally distinct tendons, we show that collagen fibrils in functionally distinct tendons have differing susceptibilities to damage under both tensile overload and cyclic fatigue loading. Our results suggest that the structure of collagen fibrils may lead to a strength versus fatigue resistance tradeoff, where high strength is gained at the expense of fatigue resistance, and vice versa.
Collapse
Affiliation(s)
- Tyler W Herod
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Neil C Chambers
- Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada
| | - Samuel P Veres
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada; Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada.
| |
Collapse
|
31
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HR. Fascicles and the interfascicular matrix show adaptation for fatigue resistance in energy storing tendons. Acta Biomater 2016; 42:308-315. [PMID: 27286677 PMCID: PMC5015572 DOI: 10.1016/j.actbio.2016.06.012] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 05/06/2016] [Accepted: 06/07/2016] [Indexed: 11/27/2022]
Abstract
Tendon is composed of rope-like fascicles, bound together by interfascicular matrix (IFM). Our previous work shows that the IFM is critical for tendon function, facilitating sliding between fascicles to allow tendons to stretch. This function is particularly important in energy storing tendons, which experience extremely high strains during exercise, and therefore require the capacity for considerable inter-fascicular sliding and recoil. This capacity is not required in positional tendons. Whilst we have previously described the quasi-static properties of the IFM, the fatigue resistance of the IFM in functionally distinct tendons remains unknown. We therefore tested the hypothesis that fascicles and IFM in the energy storing equine superficial digital flexor tendon (SDFT) are more fatigue resistant than those in the positional common digital extensor tendon (CDET). Fascicles and IFM from both tendon types were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results demonstrated that both fascicles and IFM from the energy storing SDFT were able to resist a greater number of cycles before failure than those from the positional CDET. Further, SDFT fascicles and IFM exhibited less hysteresis over the course of testing than their counterparts in the CDET. This is the first study to assess the fatigue resistance of the IFM, demonstrating that IFM has a functional role within tendon and contributes significantly to tendon mechanical properties. These data provide important advances into fully characterising tendon structure-function relationships. Statement of Significance Understanding tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for tendon injury. In this study, we demonstrate for the first time that the interfascicular matrix is able to withstand a high degree of cyclic loading, and is specialised for improved fatigue resistance in energy storing tendons. These findings highlight the importance of the interfascicular matrix in the function of energy storing tendons, and potentially provide new avenues for the development of treatments for tendon injury which specifically target the interfascicular matrix.
Collapse
|
32
|
Thorpe CT, Karunaseelan KJ, Ng Chieng Hin J, Riley GP, Birch HL, Clegg PD, Screen HRC. Distribution of proteins within different compartments of tendon varies according to tendon type. J Anat 2016; 229:450-8. [PMID: 27113131 PMCID: PMC4974547 DOI: 10.1111/joa.12485] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/18/2016] [Indexed: 01/20/2023] Open
Abstract
Although the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the energetic cost of locomotion. To maximise energy storage and return, energy‐storing tendons need to be more extensible and elastic than tendons with a purely positional function. These properties are conferred in part by a specialisation of a specific compartment of the tendon, the interfascicular matrix, which enables sliding and recoil between adjacent fascicles. However, the composition of the interfascicular matrix is poorly characterised and we therefore tested the hypothesis that the distribution of elastin and proteoglycans differs between energy‐storing and positional tendons, and that protein distribution varies between the fascicular matrix and the interfascicular matrix, with localisation of elastin and lubricin to the interfascicular matrix. Protein distribution in the energy‐storing equine superficial digital flexor tendon and positional common digital extensor tendon was assessed using histology and immunohistochemistry. The results support the hypothesis, demonstrating enrichment of lubricin in the interfascicular matrix in both tendon types, where it is likely to facilitate interfascicular sliding. Elastin was also localised to the interfascicular matrix, specifically in the energy‐storing superficial digital flexor tendon, which may account for the greater elasticity of the interfascicular matrix in this tendon. A differential distribution of proteoglycans was identified between tendon types and regions, which may indicate a distinct role for each of these proteins in tendon. These data provide important advances into fully characterising structure–function relationships within tendon.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, UK
| | - Kabelan J Karunaseelan
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, UK
| | - Jade Ng Chieng Hin
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, UK
| | - Graham P Riley
- School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich, UK
| | - Helen L Birch
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
| | - Peter D Clegg
- Department of Musculoskeletal Biology, Institute of Ageing and Chronic Disease, University of Liverpool, Neston, UK
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, UK
| |
Collapse
|
33
|
Tendon Differentiation on Decellularized Extracellular Matrix Under Cyclic Loading. Methods Mol Biol 2016; 1502:195-202. [PMID: 27062597 DOI: 10.1007/7651_2016_332] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Tendon bioreactors combine cells, scaffold, and mechanical stimulation to drive tissue neogenesis ex vivo. Faithful recapitulation of the native tendon microenvironment is essential for stimulating graft maturation or modeling tendon biology. As the mediator between cells and mechanical stimulation, the properties of a scaffold constitute perhaps the most essential elements in a bioreactor system. One method of achieving native scaffold properties is to process tendon allograft in a manner that removes cells without modifying structure and function: "decellularization." This chapter describes (1) production of tendon scaffolds derived from native extracellular matrix, (2) preparation of cell-laden scaffolds prior to bioreactor culture, and (3) tissue processing post-harvest for gene expression analysis. These methods may be applied for a variety of applications including graft production, cell priming prior to transplantation and basic investigations of tendon cell biology.
Collapse
|
34
|
Engineering Tendon: Scaffolds, Bioreactors, and Models of Regeneration. Stem Cells Int 2015; 2016:3919030. [PMID: 26839559 PMCID: PMC4709784 DOI: 10.1155/2016/3919030] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2015] [Accepted: 09/20/2015] [Indexed: 12/23/2022] Open
Abstract
Tendons bridge muscle and bone, translating forces to the skeleton and increasing the safety and efficiency of locomotion. When tendons fail or degenerate, there are no effective pharmacological interventions. The lack of available options to treat damaged tendons has created a need to better understand and improve the repair process, particularly when suitable autologous donor tissue is unavailable for transplantation. Cells within tendon dynamically react to loading conditions and undergo phenotypic changes in response to mechanobiological stimuli. Tenocytes respond to ultrastructural topography and mechanical deformation via a complex set of behaviors involving force-sensitive membrane receptor activity, changes in cytoskeletal contractility, and transcriptional regulation. Effective ex vivo model systems are needed to emulate the native environment of a tissue and to translate cell-matrix forces with high fidelity. While early bioreactor designs have greatly expanded our knowledge of mechanotransduction, traditional scaffolds do not fully model the topography, composition, and mechanical properties of native tendon. Decellularized tendon is an ideal scaffold for cultivating replacement tissue and modeling tendon regeneration. Decellularized tendon scaffolds (DTS) possess high clinical relevance, faithfully translate forces to the cellular scale, and have bulk material properties that match natural tissue. This review summarizes progress in tendon tissue engineering, with a focus on DTS and bioreactor systems.
Collapse
|
35
|
Thorpe CT, Spiesz EM, Chaudhry S, Screen HRC, Clegg PD. Science in brief: recent advances into understanding tendon function and injury risk. Equine Vet J 2015; 47:137-40. [PMID: 25644766 DOI: 10.1111/evj.12346] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- C T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, UK
| | | | | | | | | |
Collapse
|
36
|
Screen HRC, Berk DE, Kadler KE, Ramirez F, Young MF. Tendon functional extracellular matrix. J Orthop Res 2015; 33:793-9. [PMID: 25640030 PMCID: PMC4507431 DOI: 10.1002/jor.22818] [Citation(s) in RCA: 131] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Accepted: 12/13/2014] [Indexed: 02/06/2023]
Abstract
This article is one of a series, summarizing views expressed at the Orthopaedic Research Society New Frontiers in Tendon Research Conference. This particular article reviews the three workshops held under the "Functional Extracellular Matrix" stream. The workshops focused on the roles of the tendon extracellular matrix, such as performing the mechanical functions of tendon, creating the local cell environment, and providing cellular cues. Tendon is a complex network of matrix and cells, and its biological functions are influenced by widely varying extrinsic and intrinsic factors such as age, nutrition, exercise levels, and biomechanics. Consequently, tendon adapts dynamically during development, aging, and injury. The workshop discussions identified research directions associated with understanding cell-matrix interactions to be of prime importance for developing novel strategies to target tendon healing or repair.
Collapse
Affiliation(s)
- Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London, E1 4NS, United Kingdom
| | | | | | | | | |
Collapse
|
37
|
Thorpe CT, Godinho MSC, Riley GP, Birch HL, Clegg PD, Screen HRC. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons. J Mech Behav Biomed Mater 2015; 52:85-94. [PMID: 25958330 PMCID: PMC4655227 DOI: 10.1016/j.jmbbm.2015.04.009] [Citation(s) in RCA: 94] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Revised: 02/27/2015] [Accepted: 04/07/2015] [Indexed: 11/23/2022]
Abstract
While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Fascicle sliding enables high levels of extension in energy storing tendons. Sliding mechanics are governed by the interfascicular matrix (IFM). We assessed IFM extension and recovery. IFM elasticity and recovery are greater in energy storing tendons. The IFM plays an important role in the function of energy storing tendons.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS UK.
| | - Marta S C Godinho
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS UK
| | - Graham P Riley
- School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich NR4 7TJ, UK
| | - Helen L Birch
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore HA7 4LP, UK
| | - Peter D Clegg
- Department of Musculoskeletal Biology, Institute of Ageing and Chronic Disease, University of Liverpool, Leahurst Campus, Neston CH64 7TE, UK
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS UK
| |
Collapse
|
38
|
Kondratko-Mittnacht J, Duenwald-Kuehl S, Lakes R, Vanderby R. Shear load transfer in high and low stress tendons. J Mech Behav Biomed Mater 2015; 45:109-20. [PMID: 25700261 DOI: 10.1016/j.jmbbm.2015.01.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 01/14/2015] [Accepted: 01/29/2015] [Indexed: 10/24/2022]
Abstract
BACKGROUND Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructures (helical versus linear) may redistribute loads differently. METHOD OF APPROACH This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20% to 60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. RESULTS AND CONCLUSIONS Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism.
Collapse
Affiliation(s)
- Jaclyn Kondratko-Mittnacht
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Sarah Duenwald-Kuehl
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Roderic Lakes
- Materials Science Program, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Engineering Physics, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Ray Vanderby
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705, USA; Materials Science Program, University of Wisconsin-Madison, Madison, WI 53705, USA.
| |
Collapse
|
39
|
Patterson-Kane JC, Rich T. Achilles tendon injuries in elite athletes: lessons in pathophysiology from their equine counterparts. ILAR J 2015; 55:86-99. [PMID: 24936032 DOI: 10.1093/ilar/ilu004] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Superficial digital flexor tendon (SDFT) injury in equine athletes is one of the most well-accepted, scientifically supported companion animal models of human disease (i.e., exercise-induced Achilles tendon [AT] injury). The SDFT and AT are functionally and clinically equivalent (and important) energy-storing structures for which no equally appropriate rodent, rabbit, or other analogues exist. Access to equine tissues has facilitated significant advances in knowledge of tendon maturation and aging, determination of specific exercise effects (including early life), and definition of some of the earliest stages of subclinical pathology. Access to human surgical biopsies has provided complementary information on more advanced phases of disease. Importantly, equine SDFT injuries are only a model for acute ruptures in athletes, not the entire spectrum of human tendonopathy (including chronic tendon pain). In both, pathology begins with a potentially prolonged phase of accumulation of (subclinical) microdamage. Recent work has revealed remarkably similar genetic risk factors, including further evidence that tenocyte dysfunction plays an active role. Mice are convenient but not necessarily accurate models for multiple diseases, particularly at the cellular level. Mechanistic studies, including tendon cell responses to combinations of exercise-associated stresses, require a more thorough investigation of cross-species conservation of key stress pathway auditors. Molecular evidence has provided some context for the poor performance of mouse models; equines may provide better systems at this level. The use of horses may be additionally justifiable based on comparable species longevity, lifestyle factors, and selection pressure by similar infectious agents (e.g., herpesviruses) on general cell stress pathway evolution.
Collapse
|
40
|
Russo V, Mauro A, Martelli A, Di Giacinto O, Di Marcantonio L, Nardinocchi D, Berardinelli P, Barboni B. Cellular and molecular maturation in fetal and adult ovine calcaneal tendons. J Anat 2014; 226:126-42. [PMID: 25546075 PMCID: PMC4304568 DOI: 10.1111/joa.12269] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/07/2014] [Indexed: 02/06/2023] Open
Abstract
Processes of development during fetal life profoundly transform tendons from a plastic tissue into a highly differentiated structure, characterised by a very low ability to regenerate after injury in adulthood. Sheep tendon is frequently used as a translational model to investigate cell-based regenerative approaches. However, in contrast to other species, analytical and comparative baseline studies on the normal developmental maturation of sheep tendons from fetal through to adult life are not currently available. Thus, a detailed morphological and biochemical study was designed to characterise tissue maturation during mid- (2 months of pregnancy: 14 cm of length) and late fetal (4 months: 40 cm of length) life, through to adulthood. The results confirm that ovine tendon morphology undergoes profound transformations during this period. Endotenon was more developed in fetal tendons than in adult tissues, and its cell phenotype changed through tendon maturation. Indeed, groups of large rounded cells laying on smaller and more compacted ones expressing osteocalcin, vascular endothelial growth factor (VEGF) and nerve growth factor (NGF) were identified exclusively in fetal mid-stage tissues, and not in late fetal or adult tendons. VEGF, NGF as well as blood vessels and nerve fibers showed decreased expression during tendon development. Moreover, the endotenon of mid- and late fetuses contained identifiable cells that expressed several pluripotent stem cell markers [Telomerase Reverse Transcriptase (TERT), SRY Determining Region Y Box-2 (SOX2), Nanog Homeobox (NANOG) and Octamer Binding Transcription Factor-4A (OCT-4A)]. These cells were not identifiable in adult specimens. Ovine tendon development was also accompanied by morphological modifications to cell nuclei, and a progressive decrease in cellularity, proliferation index and expression of connexins 43 and 32. Tendon maturation was similarly characterised by modulation of several other gene expression profiles, including Collagen type I, Collagen type III, Scleraxis B, Tenomodulin, Trombospondin 4 and Osteocalcin. These gene profiles underwent a dramatic reduction in adult tissues. Transforming growth factor-1 expression (involved in collagen synthesis) underwent a similar decrease. In conclusion, these morphological studies carried out on sheep tendons at different stages of development and aging offer normal structural and molecular baseline data to allow accurate evaluation of data from subsequent interventional studies investigating tendon healing and regeneration in ovine experimental models.
Collapse
|
41
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HR. Effect of fatigue loading on structure and functional behaviour of fascicles from energy-storing tendons. Acta Biomater 2014; 10:3217-24. [PMID: 24747261 DOI: 10.1016/j.actbio.2014.04.008] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Revised: 03/07/2014] [Accepted: 04/08/2014] [Indexed: 11/26/2022]
Abstract
Tendons can broadly be categorized according to their function: those that act purely to position the limb and those that have an additional function as energy stores. Energy-storing tendons undergo many cycles of large deformations during locomotion, and so must be able to extend and recoil efficiently, rapidly and repeatedly. Our previous work has shown rotation in response to applied strain in fascicles from energy-storing tendons, indicating the presence of helical substructures which may provide greater elasticity and recovery. In the current study, we assessed how preconditioning and fatigue loading affect the ability of fascicles from the energy-storing equine superficial digital flexor tendon to extend and recoil. We hypothesized that preconditioned samples would exhibit changes in microstructural strain response, but would retain their ability to recover. We further hypothesized that fatigue loading would result in sample damage, causing further alterations in extension mechanisms and a significant reduction in sample recovery. The results broadly support these hypotheses: preconditioned samples showed some alterations in microstructural strain response, but were able to recover following the removal of load. However, fatigue loaded samples showed visual evidence of damage and exhibited further alterations in extension mechanisms, characterized by decreased rotation in response to applied strain. This was accompanied by increased hysteresis and decreased recovery. These results suggest that fatigue loading results in a compromised helix substructure, reducing the ability of energy-storing tendons to recoil. A decreased ability to recoil may lead to an impaired response to further loading, potentially increasing the likelihood of injury.
Collapse
|
42
|
Kondratko J, Duenwald-Kuehl S, Lakes R, Vanderby R. Mechanical compromise of partially lacerated flexor tendons. J Biomech Eng 2014; 135:011001. [PMID: 23363212 DOI: 10.1115/1.4023092] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Tendons function to transmit loads from muscle to move and stabilize joints and absorb impacts. Functionality of lacerated tendons is diminished, however clinical practice often considers surgical repair only after 50% or more of the tendon is lacerated, the "50% rule." Few studies provide mechanical insight into the 50% rule. In this study cyclic and static stress relaxation tests were performed on porcine flexor tendons before and after a 0.5, 1.0, 2.0, or 2.75 mm deep transverse, midsubstance laceration. Elastic and viscoelastic properties, such as maximum stress, change in stress throughout each test, and stiffness, were measured and compared pre- and post-laceration. Nominal stress and stiffness parameters decreased, albeit disproportionately in magnitude, with increasing percent loss of cross-sectional area. Conversely, mean stress at the residual area (determined using remaining intact area at the laceration cross section) exhibited a marked increase in stress concentration beginning at 47.2% laceration using both specified load and constant strain analyses. The marked increase in stress concentration beginning near 50% laceration provides mechanical insight into the 50% rule. Additionally, a drastic decrease in viscoelastic stress parameters after only an 8.2% laceration suggests that time-dependent mechanisms protecting tissues during impact loadings are highly compromised regardless of laceration size.
Collapse
Affiliation(s)
- Jaclyn Kondratko
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA
| | | | | | | |
Collapse
|
43
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HRC. Fascicles from energy-storing tendons show an age-specific response to cyclic fatigue loading. J R Soc Interface 2014; 11:20131058. [PMID: 24402919 DOI: 10.1098/rsif.2013.1058] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Some tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), act as energy stores, stretching and recoiling to increase efficiency during locomotion. Our previous observations of rotation in response to applied strain in SDFT fascicles suggest a helical structure, which may provide energy-storing tendons with a greater ability to extend and recoil efficiently. Despite this specialization, energy-storing tendons are prone to age-related tendinopathy. The aim of this study was to assess the effect of cyclic fatigue loading (FL) on the microstructural strain response of SDFT fascicles from young and old horses. The data demonstrate two independent age-related mechanisms of fatigue failure; in young horses, FL caused low levels of matrix damage and decreased rotation. This suggests that loading causes alterations to the helix substructure, which may reduce their ability to recoil and recover. By contrast, fascicles from old horses, in which the helix is already compromised, showed greater evidence of matrix damage and suffer increased fibre sliding after FL, which may partially explain the age-related increase in tendinopathy. Elucidation of helix structure and the precise alterations occurring owing to both ageing and FL will help to develop appropriate preventative and repair strategies for tendinopathy.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, , Mile End Road, London E1 4NS, UK
| | | | | | | | | |
Collapse
|
44
|
Shepherd JH, Legerlotz K, Demirci T, Klemt C, Riley GP, Screen HRC. Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour. Proc Inst Mech Eng H 2013; 228:49-59. [PMID: 24285289 PMCID: PMC4361498 DOI: 10.1177/0954411913509977] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Most overuse tendinopathies are thought to be associated with repeated microstrain below the failure threshold, analogous to the fatigue failure that affects materials placed under repetitive loading. Investigating the progression of fatigue damage within tendons is therefore of critical importance. There are obvious challenges associated with the sourcing of human tendon samples for in vitro analysis so animal models are regularly adopted. However, data indicates that fatigue life varies significantly between tendons of different species and with different stresses in life. Positional tendons such as rat tail tendon or the bovine digital extensor are commonly applied in in vitro studies of tendon overuse, but there is no evidence to suggest their behaviour is indicative of the types of human tendon particularly prone to overuse injuries. In this study, the fatigue response of the largely positional digital extensor and the more energy storing deep digital flexor tendon of the bovine hoof were compared to the semitendinosus tendon of the human hamstring. Fascicles from each tendon type were subjected to either stress or strain controlled fatigue loading (cyclic creep or cyclic stress relaxation respectively). Gross fascicle mechanics were monitored after cyclic stress relaxation and the mean number of cycles to failure investigated with creep loading. Bovine extensor fascicles demonstrated the poorest fatigue response, while the energy storing human semitendinosus was the most fatigue resistant. Despite the superior fatigue response of the energy storing tendons, confocal imaging suggested a similar degree of damage in all three tendon types; it appears the more energy storing tendons are better able to withstand damage without detriment to mechanics.
Collapse
Affiliation(s)
- Jennifer H Shepherd
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, London, UK
| | | | | | | | | | | |
Collapse
|
45
|
Smith RKW, Werling NJ, Dakin SG, Alam R, Goodship AE, Dudhia J. Beneficial effects of autologous bone marrow-derived mesenchymal stem cells in naturally occurring tendinopathy. PLoS One 2013; 8:e75697. [PMID: 24086616 PMCID: PMC3783421 DOI: 10.1371/journal.pone.0075697] [Citation(s) in RCA: 120] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2013] [Accepted: 08/20/2013] [Indexed: 02/06/2023] Open
Abstract
Tendon injuries are a common age-related degenerative condition where current treatment strategies fail to restore functionality and normal quality of life. This disease also occurs naturally in horses, with many similarities to human tendinopathy making it an ideal large animal model for human disease. Regenerative approaches are increasingly used to improve outcome involving mesenchymal stem cells (MSCs), supported by clinical data where injection of autologous bone marrow derived MSCs (BM-MSCs) suspended in marrow supernatant into injured tendons has halved the re-injury rate in racehorses. We hypothesized that stem cell therapy induces a matrix more closely resembling normal tendon than the fibrous scar tissue formed by natural repair. Twelve horses with career-ending naturally-occurring superficial digital flexor tendon injury were allocated randomly to treatment and control groups. 1X10(7) autologous BM-MSCs suspended in 2 ml of marrow supernatant were implanted into the damaged tendon of the treated group. The control group received the same volume of saline. Following a 6 month exercise programme horses were euthanized and tendons assessed for structural stiffness by non-destructive mechanical testing and for morphological and molecular composition. BM-MSC treated tendons exhibited statistically significant improvements in key parameters compared to saline-injected control tendons towards that of normal tendons and those in the contralateral limbs. Specifically, treated tendons had lower structural stiffness (p<0.05) although no significant difference in calculated modulus of elasticity, lower (improved) histological scoring of organisation (p<0.003) and crimp pattern (p<0.05), lower cellularity (p<0.007), DNA content (p<0.05), vascularity (p<0.03), water content (p<0.05), GAG content (p<0.05), and MMP-13 activity (p<0.02). Treatment with autologous MSCs in marrow supernatant therefore provides significant benefits compared to untreated tendon repair in enhancing normalisation of biomechanical, morphological, and compositional parameters. These data in natural disease, with no adverse findings, support the use of this treatment for human tendon injuries.
Collapse
Affiliation(s)
- Roger Kenneth Whealands Smith
- Department of Clinical Sciences and Services, the Royal Veterinary College, University of London, Hatfield, United Kingdom
| | - Natalie Jayne Werling
- Department of Biotherapeutics, National Institute for Biological Standards and Control, South Mimms, United Kingdom
| | - Stephanie Georgina Dakin
- Department of Clinical Sciences and Services, the Royal Veterinary College, University of London, Hatfield, United Kingdom
| | - Rafiqul Alam
- Department of Clinical Sciences and Services, the Royal Veterinary College, University of London, Hatfield, United Kingdom
| | - Allen E. Goodship
- Institute of Orthopaedics & Musculo-Skeletal Science, University College London, Stanmore, United Kingdom
| | - Jayesh Dudhia
- Department of Clinical Sciences and Services, the Royal Veterinary College, University of London, Hatfield, United Kingdom
- * E-mail:
| |
Collapse
|
46
|
Dourte LM, Pathmanathan L, Mienaltowski MJ, Jawad AF, Birk DE, Soslowsky LJ. Mechanical, compositional, and structural properties of the mouse patellar tendon with changes in biglycan gene expression. J Orthop Res 2013; 31:1430-7. [PMID: 23592048 PMCID: PMC3801205 DOI: 10.1002/jor.22372] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Accepted: 03/18/2013] [Indexed: 02/04/2023]
Abstract
Tendons have complex mechanical properties that depend on their structure and composition. Some studies have assessed the role of small leucine-rich proteoglycans (SLRPs) in the mechanical response of tendon, but the relationships between sophisticated mechanics, assembly of collagen and SLRPs have not been well characterized. In this study, biglycan gene expression was varied in a dose dependent manner using biglycan null, biglycan heterozygote and wild type mice. Measures of mechanical (tension and compression), compositional and structural changes of the mouse patellar tendon were evaluated. Viscoelastic, tensile dynamic modulus was found to be increased in the biglycan heterozygous and biglycan null tendons compared to wild type. Gene expression analyses revealed biglycan gene expression was closely associated in a dose-dependent allelic manner. No differences were seen between genotypes in elastic or compressive properties or quantitative measures of collagen structure. These results suggest that biglycan, a member of the SLRP family, plays a role in tendon viscoelasticity that cannot be completely explained by its role in collagen fibrillogenesis.
Collapse
Affiliation(s)
- LeAnn M. Dourte
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall 36th Street and Hamilton Walk, Philadelphia, Pennsylvania, 19104-6081
| | - Lydia Pathmanathan
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall 36th Street and Hamilton Walk, Philadelphia, Pennsylvania, 19104-6081
| | - Michael J. Mienaltowski
- Department of Molecular Pharmacology and Physiology, University of South Florida Morsani College of Medicine, Tampa, Florida
| | - Abbas F. Jawad
- Department of Pediatrics – Biostatistics and Epidemiology, University of Pennsylvania Perelman School of Medicine/Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| | - David E. Birk
- Department of Molecular Pharmacology and Physiology, University of South Florida Morsani College of Medicine, Tampa, Florida
| | - Louis J. Soslowsky
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, 424 Stemmler Hall 36th Street and Hamilton Walk, Philadelphia, Pennsylvania, 19104-6081
| |
Collapse
|
47
|
Bowser JE, Elder SH, Pasquali M, Grady JG, Rashmir-Raven AM, Wills R, Swiderski CE. Tensile properties in collagen-rich tissues of Quarter Horses with hereditary equine regional dermal asthenia (HERDA). Equine Vet J 2013; 46:216-22. [DOI: 10.1111/evj.12110] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- J. E. Bowser
- Department of Clinical Sciences; College of Veterinary Medicine; Mississippi State University; USA
| | - S. H. Elder
- Department of Agricultural & Biological Engineering; Mississippi State University; USA
| | - M. Pasquali
- Department of Pathology; University of Utah School of Medicine and ARUP Laboratories Inc.; USA
| | - J. G. Grady
- Dilworth Small Animal Hospital; Tupelo Mississippi USA
| | - A. M. Rashmir-Raven
- Department of Large Animal Clinical Sciences; College of Veterinary Medicine; Michigan State University; USA
| | - R. Wills
- Department of Pathobiology and Population Medicine; College of Veterinary Medicine; Mississippi State University; USA
| | - C. E. Swiderski
- Department of Clinical Sciences; College of Veterinary Medicine; Mississippi State University; USA
| |
Collapse
|
48
|
Helical sub-structures in energy-storing tendons provide a possible mechanism for efficient energy storage and return. Acta Biomater 2013; 9:7948-56. [PMID: 23669621 DOI: 10.1016/j.actbio.2013.05.004] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 04/18/2013] [Accepted: 05/02/2013] [Indexed: 12/26/2022]
Abstract
The predominant function of tendons is to position the limb during locomotion. Specific tendons also act as energy stores. Energy-storing (ES) tendons are prone to injury, the incidence of which increases with age. This is likely related to their function; ES tendons are exposed to higher strains and require a greater ability to recoil than positional tendons. The specialized properties of ES tendons are thought to be achieved through structural and compositional differences. However, little is known about structure-function relationships in tendons. This study uses fascicles from the equine superficial digital flexor (SDFT) and common digital extensor (CDET) as examples of ES and positional tendons. We hypothesized that extension and recoil behaviour at the micro-level would differ between tendon types, and would alter with age in the injury-prone SDFT. Supporting this, the results show that extension in the CDET is dominated by fibre sliding. By contrast, greater rotation was observed in the SDFT, suggesting a helical component to fascicles in this tendon. This was accompanied by greater recovery and less hysteresis loss in SDFT samples. In samples from aged SDFTs, the amount of rotation and the ability to recover decreased, while hysteresis loss increased. These findings indicate that fascicles in the ES SDFT may have a helical structure, enabling the more efficient recoil observed. Further, the helix structure appears to alter with ageing; this coincides with a reduction in the ability of SDFT fascicles to recoil. This may affect tendon fatigue resistance and predispose aged tendons to injury.
Collapse
|
49
|
Thorpe CT, Birch HL, Clegg PD, Screen HRC. The role of the non-collagenous matrix in tendon function. Int J Exp Pathol 2013; 94:248-59. [PMID: 23718692 DOI: 10.1111/iep.12027] [Citation(s) in RCA: 123] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2013] [Accepted: 04/16/2013] [Indexed: 01/26/2023] Open
Abstract
Tendon consists of highly ordered type I collagen molecules that are grouped together to form subunits of increasing diameter. At each hierarchical level, the type I collagen is interspersed with a predominantly non-collagenous matrix (NCM) (Connect. Tissue Res., 6, 1978, 11). Whilst many studies have investigated the structure, organization and function of the collagenous matrix within tendon, relatively few have studied the non-collagenous components. However, there is a growing body of research suggesting the NCM plays an important role within tendon; adaptations to this matrix may confer the specific properties required by tendons with different functions. Furthermore, age-related alterations to non-collagenous proteins have been identified, which may affect tendon resistance to injury. This review focuses on the NCM within the tensional region of developing and mature tendon, discussing the current knowledge and identifying areas that require further study to fully understand structure-function relationships within tendon. This information will aid in the development of appropriate techniques for tendon injury prevention and treatment.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London E1 4NS, UK.
| | | | | | | |
Collapse
|
50
|
LaCroix AS, Duenwald-Kuehl SE, Lakes RS, Vanderby R. Relationship between tendon stiffness and failure: a metaanalysis. J Appl Physiol (1985) 2013; 115:43-51. [PMID: 23599401 DOI: 10.1152/japplphysiol.01449.2012] [Citation(s) in RCA: 93] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Tendon is a highly specialized, hierarchical tissue designed to transfer forces from muscle to bone; complex viscoelastic and anisotropic behaviors have been extensively characterized for specific subsets of tendons. Reported mechanical data consistently show a pseudoelastic, stress-vs.-strain behavior with a linear slope after an initial toe region. Many studies report a linear, elastic modulus, or Young's modulus (hereafter called elastic modulus) and ultimate stress for their tendon specimens. Individually, these studies are unable to provide a broader, interstudy understanding of tendon mechanical behavior. Herein we present a metaanalysis of pooled mechanical data from a representative sample of tendons from different species. These data include healthy tendons and those altered by injury and healing, genetic modification, allograft preparation, mechanical environment, and age. Fifty studies were selected and analyzed. Despite a wide range of mechanical properties between and within species, elastic modulus and ultimate stress are highly correlated (R(2) = 0.785), suggesting that tendon failure is highly strain-dependent. Furthermore, this relationship was observed to be predictable over controlled ranges of elastic moduli, as would be typical of any individual species. With the knowledge gained through this metaanalysis, noninvasive tools could measure elastic modulus in vivo and reasonably predict ultimate stress (or structural compromise) for diseased or injured tendon.
Collapse
Affiliation(s)
- Andrew S LaCroix
- Department of Biomedical Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA
| | | | | | | |
Collapse
|