1
|
Ludovichetti R, Gorup D, Krepuska M, Winklhofer S, Thurner P, Madjidyar J, Flohr T, Piccirelli M, Michels L, Alkadhi H, Mergen V, Kulcsar Z, Schubert T. Ultra-high resolution CT angiography for the assessment of intracranial stents and flow diverters using photon counting detector CT. J Neurointerv Surg 2025:jnis-2024-022041. [PMID: 39438133 DOI: 10.1136/jnis-2024-022041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Accepted: 09/25/2024] [Indexed: 10/25/2024]
Abstract
BACKGROUND The patency of intracranial stents may not be reliably assessed with either CT angiography or MR angiography due to imaging artifacts. We investigated the potential of ultra-high resolution CT angiography using a photon counting detector (PCD) CT to address this limitation by optimizing scanning and reconstruction parameters. METHODS A phantom with different flow diverters was used to optimize PCD-CT reconstruction parameters, followed by imaging of 14 patients with intracranial stents using PCD-CT. Images were reconstructed using three kernels based on the phantom results (Hv56, Hv64, and Hv72; Hv=head vascular) and one kernel to virtually match the resolution of standard CT angiography (Hv40). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements were calculated. Subjective image quality and diagnostic confidence (DC) were assessed using a five point visual grading scale (5=best, 1=worst) and a three point grading scale (1=best, 3=worst), respectively, by two independent neuroradiologists. RESULTS Phantom images demonstrated the highest image quality across dose levels for 0.2 mm reconstructions with Hv56 (4.5), Hv64 (5), and Hv72 (5). In patient images, SNR and CNR decreased significantly with increasing kernel sharpness compared with control parameters. All reconstructions showed significantly higher image quality and DC compared with the control reconstruction with Hv40 kernel (P<0.001), with both image quality and DC being highest with Hv64 (0.2 mm) and Hv72 (0.2 mm) reconstructions. CONCLUSION Ultra-high resolution PDC-CT angiography provides excellent visualization of intracranial stents, with optimal reconstructions using the Hv64 and the Hv72 kernels at 0.2 mm. REGISTRATION BASEC 2021-00343.
Collapse
Affiliation(s)
- Riccardo Ludovichetti
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Dunja Gorup
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Mikos Krepuska
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Sebastian Winklhofer
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Patrick Thurner
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Jawid Madjidyar
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Thomas Flohr
- Department of Diagnostic and Interventional Radiology, University of Zurich, Zurich, Switzerland
| | - Marco Piccirelli
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Lars Michels
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- Department of Diagnostic and Interventional Radiology, University of Zurich, Zurich, Switzerland
| | - Victor Mergen
- Department of Diagnostic and Interventional Radiology, University of Zurich, Zurich, Switzerland
| | - Zsolt Kulcsar
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Tilman Schubert
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Kim I, Ahn SJ, Park M, Joo B, Kim J, Suh SH. Diagnostic Performance of Pointwise Encoding Time Reduction with Radial Acquisition Subtraction-based MR Angiography in the Follow-up of Intracranial Aneurysms after Clipping. Clin Neuroradiol 2024; 34:597-603. [PMID: 38456913 DOI: 10.1007/s00062-024-01399-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 02/12/2024] [Indexed: 03/09/2024]
Abstract
PURPOSE While follow-up assessment of clipped aneurysms (CAs) using magnetic resonance angiography (MRA) can be challenging due to susceptibility artifacts, a novel MRA sequence pointwise encoding time reduction with radial acquisition (PETRA) subtraction-based MRA, has been developed to reduce these artifacts. The aim of the study was to validate the diagnostic performance of PETRA-MRA by comparing it with digital subtraction angiography (DSA) as a reference for follow-up of CAs using a 3T MR scanner. METHODS Patients with clipping who underwent both PETRA-MRA and DSA between September 2019 and December 2021 were retrospectively included. Two neuroradiologists independently reviewed with the reconstructed images of PETRA-MRA to assess the visibility of the arteries around the clips and aneurysm recurrence or remnants of CA using a 3-point scale. The diagnostic accuracy of PETRA-MRA was evaluated in comparison to DSA. RESULTS The study included 34 patients (28 females, mean age 59 ± 9.6 years) with 48 CAs. The PETRA-MRA allowed visualization of the parent vessels around the clips in 98% of cases, compared to 39% with time-of-flight (TOF) MRA (p < 0.0001). The DSA confirmed 14 (29.2%) residual or recurrent aneurysms. The PETRA-MRA demonstrated a high accuracy, specificity, positive predictive value, and negative predictive value of 99.2%, 100%, 100%, and 97.8%, respectively, while the sensitivity was 66.7%. CONCLUSION This retrospective study demonstrates that PETRA-MRA provides excellent visibility of adjacent vessels near clips and has a high diagnostic accuracy in detecting aneurysm remnants or recurrences in CAs. Further prospective studies are warranted to establish its utility as a reliable alternative for follow-up after clipping.
Collapse
Affiliation(s)
- Inyoung Kim
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Sung Jun Ahn
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Mina Park
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Bio Joo
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Junhyung Kim
- Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of)
| | - Sang Hyun Suh
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea (Republic of).
| |
Collapse
|
3
|
Wang P, Shan Y, Xiao B, Zhang X, Hou J, Cui N, Cao X, Cheng K. How to Omit the Potential Pitfalls in Distal Radial Access: Lessons From Cadaveric and CTA Analysis. J Endovasc Ther 2024:15266028241229062. [PMID: 38326308 DOI: 10.1177/15266028241229062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2024]
Abstract
OBJECTIVES To verify the anatomical basis, ideal puncture sites, and potential pitfalls of the distal radial artery (dRA) in the anatomical snuffbox region for distal radial access (dTRA). MATERIALS AND METHODS Overall, 26 formalin-fixed upper limbs and computed tomography angiography (CTA) of the upper limbs of 168 consecutive patients were studied. Cadaveric dissection and dRA 3D reconstruction were used to evaluate the dRA route for dTRA. The puncture sites, dRA diameter, and angle of the dRA and tendons of the extensor pollicis brevis were also measured in the patients and cadavers. RESULTS The cadaver dissection provided more insights than did the dRA 3D reconstruction. However, preoperative evaluation had better diagnostic accuracy (p=0.024). Puncture sites 1 and 3 had a high success rate (63.2% possible success rate, 191/302). The DISFAVOR theory was put forward, in which 8 types of potential pitfalls that may interrupt puncture procedure or lead to a surgical failure were observed, including occlusion, stenosis, tortuosity, arteriovenous fistula, angioma, different radial artery (RA) ramifications, radial veins, and cephalic veins. The mean diameter of dRA based on cadaver dissection and CTA was 2.53 (SD=0.73) and 2.63 (SD=0.69) mm, respectively. Furthermore, the minimum distance from the outer layer of dRA to the skin was 5.71 (SD=2.0) mm based on CTA. The angle between the dRA and tendons of extensor pollicis brevis (TEPB) based on cadaver dissection and CTA was 58.0° (SD=21.5°) and 51.8° (SD=16.6°), respectively. CONCLUSIONS Puncture sites 1 and 3 were more suitable for the dTRA, and we put forward the DISFAVOR theory to summarize the 8 types of potential pitfalls during the use of dTRA.
Collapse
Affiliation(s)
- Ping Wang
- Department of Radiology and Intervention, China-Japan Union Hospital of Jilin University, Changchun, China
- Department of Anatomy, Tarim University School of Medicine, Alaer, China
| | - Yuezhan Shan
- Department of Gastrointestinal Colorectal and Anal Surgery, China-Japan Union Hospital of Jilin University, Changchun, China
| | - Benshan Xiao
- Department of Intervention, Affiliated Hospital of Jinggangshan University, Jian, China
| | - Xiang Zhang
- Department of Anatomy, Kunming Medical University, Kunming, China
| | - Jianfei Hou
- Department of Anatomy, Tarim University School of Medicine, Alaer, China
| | - Ni Cui
- Department of Gastrointestinal Colorectal and Anal Surgery, China-Japan Union Hospital of Jilin University, Changchun, China
| | - Xianglong Cao
- Department of Gastrointestinal Surgery, Beijing Hospital, National Center of Gerontology; Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, China
| | - Kailiang Cheng
- Department of Radiology and Intervention, China-Japan Union Hospital of Jilin University, Changchun, China
| |
Collapse
|
4
|
Abramyan AA, Pilipenko YV, Belousova OB, Shmelev ND, Eliava SS. [Microsurgical and endovascular treatment of residual and recurrent cerebral aneurysms]. ZHURNAL VOPROSY NEIROKHIRURGII IMENI N. N. BURDENKO 2023; 87:107-115. [PMID: 37650283 DOI: 10.17116/neiro202387041107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Cerebral aneurysms are characterized by high risk of adverse outcome due to severe intracranial hemorrhages and their consequences. Aneurysm remnants after incomplete exclusion can cause hemorrhage. Filling of these fragments immediately after surgery is usually defined as residual aneurysms. Recurrent aneurysms develop in the area of excluded aneurysm in long-term period after surgery. The authors analyze foreign and national literature data on the diagnosis and management of residual and recurrent aneurysms. Risk factors, the most common classifications, diagnostic methods and surgical treatment are presented.
Collapse
Affiliation(s)
| | | | | | - N D Shmelev
- Burdenko Neurosurgical Center, Moscow, Russia
| | | |
Collapse
|
5
|
Kim JH, Ahn SJ, Park M, Kim YB, Joo B, Lee W, Suh SH. Follow-up imaging of clipped intracranial aneurysms with 3-T MRI: comparison between 3D time-of-flight MR angiography and pointwise encoding time reduction with radial acquisition subtraction-based MR angiography. J Neurosurg 2022; 136:1260-1265. [PMID: 34715654 DOI: 10.3171/2021.7.jns211197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Accepted: 07/01/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Metallic susceptibility artifact due to implanted clips is a major limitation of using 3D time-of-flight magnetic resonance angiography (TOF-MRA) for follow-up imaging of clipped aneurysms (CAs). The purpose of this study was to compare pointwise encoding time reduction with radial acquisition (PETRA) subtraction-based MRA with TOF-MRA in terms of imaging quality and visibility of clip-adjacent arteries for use in follow-up imaging of CAs. METHODS Sixty-two patients with 73 CAs were included retrospectively in this comparative study. All patients underwent PETRA-MRA after TOF-MRA performed simultaneously with 3-T MRI between September 2019 and March 2020. Two neuroradiologists independently compared images obtained with both MRA modalities to evaluate overall image quality using a 4-point scale and visibility of the parent artery and branching vessels near the clips using a 3-point scale. Subgroup analysis was performed according to the number of clips (less-clipped [1-2 clips] vs more-clipped [≥ 3 clips] aneurysms). The ability to detect aneurysm recurrence was also assessed. RESULTS Compared with TOF-MRA, PETRA-MRA showed acceptable image quality (score of 3.97 ± 0.18 for TOF-MRA vs 3.73 ± 0.53 for PETRA-MRA) and had greater visibility of the adjacent vessels near the CAs (score of 1.25 ± 0.59 for TOF-MRA vs 2.27 ± 0.75 for PETRA-MRA, p < 0.0001). PETRA-MRA had greater visibility of vessels adjacent to less-clipped aneurysms (score of 2.39 ± 0.75 for less-clipped aneurysms vs 2.09 ± 0.72 for more-clipped aneurysms, p = 0.014). Of 73 CAs, aneurysm recurrence in 4 cases was detected using PETRA-MRA. CONCLUSIONS This study demonstrated that PETRA-MRA is superior to TOF-MRA for visualizing adjacent vessels near clips and can be an advantageous alternative to TOF-MRA for follow-up imaging of CAs.
Collapse
Affiliation(s)
- Jae Ho Kim
- 1Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea; and
| | - Sung Jun Ahn
- 2Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Mina Park
- 2Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Yong Bae Kim
- 1Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea; and
| | - Bio Joo
- 2Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Woosung Lee
- 1Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea; and
| | - Sang Hyun Suh
- 2Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
6
|
Sebök M, Dufour JP, Cenzato M, Kaku Y, Tanaka M, Tsukahara T, Regli L, Esposito G. When Is Diagnostic Subtraction Angiography Indicated Before Clipping of Unruptured and Ruptured Intracranial Aneurysms? An International Survey of Current Practice. ACTA NEUROCHIRURGICA. SUPPLEMENT 2021; 132:9-17. [PMID: 33973023 DOI: 10.1007/978-3-030-63453-7_2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
Abstract
INTRODUCTION The goal of this survey is to investigate the indications for preoperative digital subtraction angiography (DSA) before clipping of ruptured and unruptured intracranial aneurysms in an international panel of neurovascular specialists. METHODS An anonymous survey of 23 multiple-choice questions relating to indications for DSA before clipping of an intracranial aneurysm was distributed to the international panel of attendees of the European-Japanese Cerebrovascular Congress (EJCVC), which took place in Milan, Italy on 7-9 June 2018. The survey was collected during the same conference. Descriptive statistics were used to analyze the data. RESULTS A total of 93 surveys were distributed, and 67 (72%) completed surveys were returned by responders from 13 different countries. Eighty-five percent of all responders were neurosurgeons. For unruptured and ruptured middle cerebral artery (MCA) aneurysms without life-threatening hematoma, approximately 60% of responders perform surgery without preoperative DSA. For aneurysms in other locations than MCA, microsurgery is done without preoperative DSA in 68% of unruptured and in 73% of ruptured cases. In cases of ruptured MCA or ruptured non-MCA aneurysms with life-threatening hematoma, surgery is performed without DSA in 97% and 96% of patients, respectively. Factors which lead to preoperative DSA being performed were: aneurysmal shape (fusiform, dissecting), etiology (infectious), size (>25 mm), possible presence of perforators or efferent vessels arising from the aneurysm, intra-aneurysmal thrombus, previous treatment, location (posterior circulation and paraclinoid aneurysm) and flow-replacement bypass contemplated for final aneurysm treatment. These are all factors that qualify an aneurysm as a complex aneurysm. CONCLUSION There is still a high variability in the surgeons' preoperative workup regarding the indication for DSA before clipping of ruptured and unruptured intracranial aneurysms, except for ruptured aneurysms with life-threatening hematoma. There is a general consensus among cerebrovascular specialists that any angioanatomical feature indicating a complex aneurysm should lead to a more detailed workup including preoperative DSA.
Collapse
Affiliation(s)
- Martina Sebök
- Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Jean-Philippe Dufour
- Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Marco Cenzato
- Department of Neurosurgery, Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Yasuhiko Kaku
- Department of Neurosurgery, Asahi University Murakami Memorial Hospital, Gifu, Japan
| | | | - Tetsuya Tsukahara
- Department of Neurosurgery, National Hospital Organization, Kyoto Medical Center, Kyoto, Japan
| | - Luca Regli
- Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Giuseppe Esposito
- Department of Neurosurgery, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
| |
Collapse
|
7
|
Obermueller K, Hostettler I, Wagner A, Boeckh-Behrens T, Zimmer C, Gempt J, Meyer B, Wostrack M. Frequency and risk factors for postoperative aneurysm residual after microsurgical clipping. Acta Neurochir (Wien) 2021; 163:131-138. [PMID: 33216209 PMCID: PMC7778624 DOI: 10.1007/s00701-020-04639-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 10/27/2020] [Indexed: 12/20/2022]
Abstract
OBJECTIVE Aneurysm residuals after clipping are a well-known problem, but the course of aneurysm remnants in follow-up is not well studied. No standards or follow-up guidelines exist for treatment of aneurysm remnants. The aim of this study was to evaluate the risk factors for postoperative aneurysm remnants and their changes during follow-up. METHODS We performed a retrospective analysis of 666 aneurysms treated via clipping in our hospital from 2006 to 2016. Postoperative and follow-up angiographic data were analyzed for aneurysm remnants and regrowth. Clinical parameters and aneurysm-specific characteristics were correlated with radiological results. RESULTS The frequency of aneurysm residuals was 12% (78/666). Aneurysms located in the middle cerebral artery (p = 0.02) showed a significantly lower risk for incomplete aneurysm occlusion. Larger aneurysms with a diameter of 11-25 mm (p = 0.005) showed a significantly higher risk for incomplete aneurysm occlusion. Five patients underwent re-clipping during the same hospital stay. Remnants were stratified based on morphological characteristics into "dog ears" (n = 60) and "broad based" (n = 13). The majority of the "dog ears" stayed stable, decreased in size, or vanished during follow-up. Broad-based remnants showed a higher risk of regrowth. CONCLUSIONS A middle cerebral artery location seems to lower the risk for the incomplete clip occlusion of an aneurysm. Greater aneurysm size (11-25 mm) is associated with a postoperative aneurysm remnant. The majority of "dog-ear" remnants appear to remain stable during follow-up. In these cases, unnecessarily frequent angiographic checks could be avoided. By contrast, broad-based residuals show a higher risk of regrowth that requires close imaging controls if retreatment cannot be performed immediately.
Collapse
Affiliation(s)
- Kathrin Obermueller
- Department of Neurosurgery, Klinikum rechts der Isar, Technical University Munich, Ismaninger Straße 22, 81675, Munich, Germany.
| | - Isabel Hostettler
- Department of Neurosurgery, Klinikum rechts der Isar, Technical University Munich, Ismaninger Straße 22, 81675, Munich, Germany
| | - Arthur Wagner
- Department of Neurosurgery, Klinikum rechts der Isar, Technical University Munich, Ismaninger Straße 22, 81675, Munich, Germany
| | - Tobias Boeckh-Behrens
- Department of Neuroradiology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Straße 22, 81675, Munich, Germany
| | - Claus Zimmer
- Department of Neuroradiology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Straße 22, 81675, Munich, Germany
| | - Jens Gempt
- Department of Neurosurgery, Klinikum rechts der Isar, Technical University Munich, Ismaninger Straße 22, 81675, Munich, Germany
| | - Bernhard Meyer
- Department of Neurosurgery, Klinikum rechts der Isar, Technical University Munich, Ismaninger Straße 22, 81675, Munich, Germany
| | - Maria Wostrack
- Department of Neurosurgery, Klinikum rechts der Isar, Technical University Munich, Ismaninger Straße 22, 81675, Munich, Germany
| |
Collapse
|
8
|
Pilipenko YV, Eliava SS, Pronin IN, Okishev DN, Abramyan AA. [Completeness of brain aneurysm exclusion according to CT angiography]. ZHURNAL VOPROSY NEĬROKHIRURGII IMENI N. N. BURDENKO 2020; 84:76-85. [PMID: 33306302 DOI: 10.17116/neiro20208406176] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
OBJECTIVE To develop a classification of the completeness of brain aneurysm exclusion according to CT angiography for determining further diagnostic and curative strategy. MATERIAL AND METHODS The study included 138 patients who had 164 brain aneurysms. Clipping was carried out at the Burdenko Neurosurgery Center in 2013-2017. Titanium clips were used in 111 cases, cobalt clips - in 53 patients. RESULTS Completeness of brain aneurysm exclusion was assessed in 149 cases using CT angiography. In 15 cases, artifacts from cobalt clips impaired assessment. Total exclusion was achieved in 136 (91.3%) cases, subtotal (a remainder of residual neck) - in 10 (6.7%) cases, complete exclusion of the body and bottom (patent neck) - 2 (1.3%) patients, partial exclusion (partially patent bottom) - 1 patient (0.7%). In this series, a clip prevented complete contrast enhancement of brain aneurysm bottom in all cases. CONCLUSION CTA is a reliable method for assessing the quality of exclusion of brain aneurysm in patients with implanted titanium clips. In case of cobalt clips, stratification depending on severity of CT artifacts should be performed for data interpretation. In some cases, artifacts impair visualization of the vessels adjacent to the clips. In these patients, direct cerebral angiography or dual-energy computed tomography scanners with metal artifact suppression programs should be recommended. Follow-up is recommended for patients with remnants of residual cervix. Redo surgery is indicated for completely patent neck, as well as partial or complete contrast enhancement of aneurysm bottom.
Collapse
Affiliation(s)
| | | | - I N Pronin
- Burdenko Center of Neurosurgery, Moscow, Russia
| | - D N Okishev
- Burdenko Center of Neurosurgery, Moscow, Russia
| | | |
Collapse
|
9
|
Kim JJ, Cho KC, Suh SH, Chung J, Jang CK, Joo JY, Kim YB. Evaluation of the angiographic outcomes after clipping of intracranial aneurysms: determination of predisposing factors for occurrence of aneurysm remnants. Neurol Res 2020; 42:354-360. [PMID: 32100635 DOI: 10.1080/01616412.2020.1732594] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Objectives: Aneurysm remnants after microsurgical clipping have a risk of regrowth and rupture and have not been validated in the era of three-dimensional angiography. Therefore, this study aimed to evaluate the angiographic outcome using three-dimensional rotational images and determine the predictors for remnants after microsurgical clipping.Methods: Between January 2014 and May 2017, 139 aneurysms in 106 patients who were treated with microsurgical clipping, were eligible for this study. For the determination of aneurysm remnants after microsurgical clipping, the angiographic outcomes were evaluated using follow-up digital subtraction angiography within 7 days for unruptured aneurysms or within 2 weeks for ruptured aneurysms. According to the Sindou classification, the aneurysm remnants were dichotomized, and subgroup analysis was performed to identify the predictors of aneurysm remnants after clipping with various imaging parameters and clinical information.Results: The overall rate of aneurysm remnants was 29.5% (41/139), in which retreatments were needed in 6.5% (9/139). The neck size and maximum diameter of aneurysms were independent predisposing factors for the aneurysm remnants that need retreatment (OR: 2.30; p < 0.001; OR: 1.38; p < 0.001, respectively).Conclusions: This study demonstrated a low incidence of aneurysm remnants after microsurgical clipping which need to retreatment. However, selective postoperative angiography could provide us clear information of surgical result and evidence for long-term follow-up for some aneurysms with larger neck size (>5.7 mm) and maximum diameter (>7.1 mm).
Collapse
Affiliation(s)
- Jung-Jae Kim
- Department of Neurosurgery, Ewha Womans University Seoul Hospital, Ewha Womans University College of Medicine, Seoul, South Korea
| | - Kwang-Chun Cho
- Department of Neurosurgery, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, Incheon, South Korea
| | - Sang Hyun Suh
- Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Joonho Chung
- Department of Neurosurgery, Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Chang Ki Jang
- Department of Neurosurgery, Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Jin-Yang Joo
- Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| | - Yong Bae Kim
- Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea
| |
Collapse
|
10
|
Spiessberger A, Vogt DR, Fandino J, Marbacher S. Formation of intracranial de novo aneurysms and recurrence after neck clipping: a systematic review and meta-analysis. J Neurosurg 2020; 132:456-464. [PMID: 30797217 DOI: 10.3171/2018.10.jns181281] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Accepted: 10/26/2018] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Incidence rates of de novo aneurysm formation and recurrence after clip ligation remain controversial. In this meta-analysis, the authors provide data on pooled annual incidence rates and the association of patient characteristics with time to formation of de novo aneurysms and time to recurrence after clipping. METHODS A search of the literature up to June 15, 2016, on PubMed and a systematic review were performed. The association of age, aneurysm rupture status, aneurysm multiplicity, and anatomical location with time to recurrence or formation of de novo aneurysm was estimated using multivariable Cox proportional-hazards models. Kaplan-Meier estimates (event-free survival curves) are shown. Pooled annualized incidence rates of recurrent and de novo aneurysms were estimated using Poisson regression. Proportions of aneurysms and average follow-up times are displayed as bubble plots with LOESS smoothers weighted for study size. RESULTS Of the 7606 articles screened, 92 were included in the study. Case reports on 101 patients with recurrent aneurysms and 132 patients with de novo aneurysms were analyzed. Long-term follow-up studies on de novo aneurysm formation included 13,723 patients with 101,378 patient-years of follow-up; studies on aneurysm recurrence included 5922 patients with 31,055 patient-years of follow-up. Mean time to recurrence was 12.9 ± 6.6 years (mean ± standard deviation), and mean time to de novo formation was 9.3 ± 6.1 years. No association with sex, aneurysm location, and initial rupture could be shown. De novo aneurysms occurred later in patients with multiplicity of aneurysms at diagnosis (HR 0.63, p = 0.03) and in patients with increasing age (HR per 10 yrs 0.88, p = 0.06). Pooled annualized incidence rates were 0.35% for de novo aneurysms and 0.13% for recurrent aneurysms. CONCLUSIONS Despite low reported annual incidence rates, the cumulative risk of 9.6%-22% for aneurysm recurrence or de novo formation 20 years after clip ligation warrants lifelong follow-up. Screening at 5, 10, and 20 years would detect 30.8% (95% CI 23.3%-37.6%), 64.2% (95% CI 55.9%-70.9%), and 95.9% (95% CI 90.9%-97.9%) of de novo aneurysms. Screening for recurrent aneurysms at 10, 15, and 20 years would detect 36.6% (95% CI 26.5%-45.4%), 65.3% (95% CI 54.7%-73.5%), and 95.1% (95% CI 85.8%-96.6%) of lesions.
Collapse
Affiliation(s)
| | - Deborah R Vogt
- 2Clinical Trial Unit, Department of Clinical Research, University of Basel, University Hospital Basel, Switzerland
| | | | | |
Collapse
|
11
|
Kim HJ, Yoon DY, Kim ES, Yun EJ, Jeon HJ, Lee JY, Cho BM. 256-row multislice CT angiography in the postoperative evaluation of cerebral aneurysms treated with titanium clips: using three-dimensional rotational angiography as the standard of reference. Eur Radiol 2019; 30:2152-2160. [PMID: 31844961 DOI: 10.1007/s00330-019-06560-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 10/13/2019] [Accepted: 10/30/2019] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To assess the diagnostic accuracy of 256-row multislice computed tomographic angiography (CTA) compared with three-dimensional rotational angiography (3DRA) in the postoperative evaluation of cerebral aneurysms treated with titanium clips. METHODS A total of 128 patients (42 men, 86 women; mean age, 57.6 years) with 143 cerebral aneurysms treated using titanium clips underwent both CTA and 3DRA. Two reviewers retrospectively evaluated the following parameters on CTA and 3DRA: (1) residual/recurrent aneurysm (absent or present), (2) patency of parent artery (patent or occluded/severe stenotic (> 70%)), and (3) patency of adjacent branch (patent or occluded/absent). RESULTS A total of 24 residual/recurrent aneurysms were detected by 3DRA. The sensitivity, specificity, and accuracy of CTA for the detection of residual/recurrent aneurysms were 83.3%, 100%, and 97.2% for reviewer 1 and 79.2%, 100%, and 96.5% for reviewer 2, respectively. The sensitivity, specificity, and accuracy of CTA for the evaluation of patency of parent artery were 100%, 100%, and 100%, respectively, for both reviewers. The sensitivity, specificity, and accuracy of CTA for evaluation of the patency of adjacent branch were 85.1%, 100%, and 92.3% for reviewer 1 and 82.4%, 100%, and 90.9% for reviewer 2, respectively. CONCLUSION A 256-row multislice CTA is a valuable non-invasive tool for assessment of cerebral aneurysms treated with titanium clips. KEY POINTS • A 256-row multislice CTA is an accurate imaging technique for the postoperative assessment of cerebral aneurysms treated with titanium clips. • Sensitivity of CTA for the detection of residual/recurrent aneurysms was 79-83% compared with 3DRA. • CTA is still limited in detecting residual/recurrent aneurysms of < 2 mm and small adjacent branches.
Collapse
Affiliation(s)
- Hye Jeong Kim
- Department of Radiology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1, Singil-ro, Yeongdeungpo-gu, Seoul, 07441, South Korea
| | - Dae Young Yoon
- Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 150, Seongan-ro, Gangdong-gu, Seoul, 05355, South Korea.
| | - Eun Soo Kim
- Department of Radiology, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, 22, Gwanpyeong-ro 170 beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14068, South Korea
| | - Eun Joo Yun
- Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 150, Seongan-ro, Gangdong-gu, Seoul, 05355, South Korea
| | - Hong Jun Jeon
- Department of Neurosurgery, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 150, Seongan-ro, Gangdong-gu, Seoul, 05355, South Korea
| | - Jong Young Lee
- Department of Neurosurgery, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 150, Seongan-ro, Gangdong-gu, Seoul, 05355, South Korea
| | - Byung-Moon Cho
- Department of Neurosurgery, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, 150, Seongan-ro, Gangdong-gu, Seoul, 05355, South Korea
| |
Collapse
|
12
|
Marbacher S, Mendelowitsch I, Grüter BE, Diepers M, Remonda L, Fandino J. Comparison of 3D intraoperative digital subtraction angiography and intraoperative indocyanine green video angiography during intracranial aneurysm surgery. J Neurosurg 2019; 131:64-71. [PMID: 30004279 DOI: 10.3171/2018.1.jns172253] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2017] [Accepted: 01/16/2018] [Indexed: 11/06/2022]
Abstract
OBJECTIVE During the last decade, improvements in real-time, high-resolution imaging of surgically exposed cerebral vasculature have been realized with the successful introduction of intraoperative indocyanine green video angiography (ICGVA) and technical advances in intraoperative digital subtraction angiography (DSA). With the availability of 3D intraoperative DSA (3D-iDSA) in hybrid operating rooms, the present study offers a contemporary comparison for rates of accuracy and discordance. METHODS In this retrospective study of prospectively collected data, 140 consecutive patients underwent microsurgical treatment of intracranial aneurysms (IAs) in a hybrid operating room. Variables analyzed included patient demographics, aneurysm-specific characteristics, intraoperative ICGVA and 3D-iDSA findings, and the need for intraoperative clip readjustment. The authors defined the discordance rate of the two modalities as a false-negative finding that necessitated clip repositioning after 3D-iDSA. RESULTS In 120 patients, ICGVA and 3D-iDSA were used to evaluate 134 IA obliterations. Of 215 clips used, 29 (14%) were repositioned intraoperatively, improving the surgical result in all 29 patients (24%). Repositioning was prompted by visual inspection and microvascular Doppler ultrasonography in 8 (28%), ICGVA in 13 (45%), and 3D-iDSA in 7 (24%) patients. Clip repositioning was needed in 7 patients (6%) based on 3D-iDSA, yielding an ICGVA accuracy rate of 94%. Five (71%) of the ICGVA-3D-iDSA discordances that prompted clip repositioning occurred at the anterior communicating artery complex. CONCLUSIONS A combination of vascular monitoring techniques most often achieved correct intraoperative interpretation of complete IA occlusion and parent artery integrity. Compared with 3D-iDSA imaging, ICGVA demonstrated high accuracy. Despite the relatively low discordance rate, iDSA was confirmed to be the gold standard. Improved imaging quality, including 3D-iDSA, supports its routine use in IA surgery, obviating the need for postoperative DSA.
Collapse
Affiliation(s)
| | | | | | - Michael Diepers
- 2Division of Neuroradiology, Department of Radiology, Kantonsspital Aarau, Switzerland
| | - Luca Remonda
- 2Division of Neuroradiology, Department of Radiology, Kantonsspital Aarau, Switzerland
| | | |
Collapse
|
13
|
Evaluation of the yield of post-clipping angiography and nationwide current practice. Acta Neurochir (Wien) 2019; 161:783-790. [PMID: 30783804 PMCID: PMC6431297 DOI: 10.1007/s00701-019-03834-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Accepted: 01/31/2019] [Indexed: 01/01/2023]
Abstract
BACKGROUND Surgical treatment of intracranial saccular aneurysms aims to prevent (re)hemorrhage by complete occlusion of the aneurysmal lumen. It is unclear whether routine postoperative imaging, to assess aneurysmal occlusion, is necessary since intraoperative assessment by the neurosurgeon may be sufficient. We assessed routine clinical protocols for post-clipping imaging in the Netherlands and determined whether intraoperative assessment of aneurysm clippings sufficiently predicts aneurysm residuals. METHODS A survey was conducted to assess postoperative imaging protocols in centers performing clipping of intracranial aneurysms in the Netherlands (n = 9). Furthermore, a retrospective single-center cohort study was performed to determine the predictive value of intraoperative assessment of aneurysm occlusion in relation to postoperative digital subtraction angiography (DSA) findings, between 2009 and 2017. RESULTS No center performed intraoperative DSA in a hybrid OR, routinely. Respectively, four (44.4%), seven (77.8%), and three (33.3%) centers did not routinely perform early postoperative imaging, late follow-up imaging, or any routine imaging at all. Regarding our retrospective study, 106 patients with 132 clipped aneurysms were included. There were 23 residuals ≥ 1 mm (17.4%), of which 10 (43.5%) were unexpected. For the presence of these residuals, intraoperative assessment showed a sensitivity of 56.5%, a specificity of 86.2%, a positive predictive value of 46.4%, and a negative predictive value of 90.4%. CONCLUSIONS There is lack of consensus regarding the post-clipping imaging strategy in the Netherlands. Since intraoperative assessment is shown to be insufficient to predict postoperative aneurysm residuals, we advocate routine postoperative imaging after aneurysm clipping unless this is not warranted on the basis of patient age, clinical condition, and/or comorbidity.
Collapse
|
14
|
Yun SY, Heo YJ, Jeong HW, Baek JW, Choo HJ, Shin GW, Kim ST, Jeong YG, Lee JY, Jung HS. Dual-energy CT angiography-derived virtual non-contrast images for follow-up of patients with surgically clipped aneurysms: a retrospective study. Neuroradiology 2019; 61:747-755. [DOI: 10.1007/s00234-019-02170-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Accepted: 01/15/2019] [Indexed: 11/29/2022]
|
15
|
Duarte Conde MP, de Korte AM, Meijer FJA, Aquarius R, Boogaarts HD, Bartels RHMA, de Vries J. Subtraction CTA: An Alternative Imaging Option for the Follow-Up of Flow-Diverter-Treated Aneurysms? AJNR Am J Neuroradiol 2018; 39:2051-2056. [PMID: 30287460 DOI: 10.3174/ajnr.a5817] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2018] [Accepted: 08/09/2018] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE This was a pilot study to explore the diagnostic accuracy and safety of subtraction CTA combined with a single-energy metal artifact reduction algorithm (SEMAR) compared to DSA for the evaluation of intracranial aneurysm occlusion after flow diverter treatment. MATERIALS AND METHODS We included patients treated with a flow diverter for an unruptured intracranial aneurysm between November 2015 and November 2016. The patient cohort comprised 2 groups: those who underwent follow-up imaging 1 month after flow-diverter treatment and those with a known residual intracranial aneurysm after flow diverter treatment who underwent imaging at regular follow-ups. Full-brain subtraction CTA was performed on a 320-detector row CT system. A low-dose non-enhanced volume acquisition was followed by a contrast-enhanced volume CTA. Iterative and noise-reduction filters, SEMAR, and SURESubtraction algorithms were applied. DSA was performed on a flat panel C-arm angiography system. Standard posteroanterior, lateral, 3D, and detailed 2D acquisitions were performed. Imaging was independently scored by 2 clinicians. Aneurysm occlusion (Raymond scale) was our primary outcome parameter. RESULTS Thirteen intracranial aneurysms were evaluated with subtraction CTA and DSA. Nine aneurysm remnants were demonstrated by both subtraction CTA and DSA. The sensitivity and specificity of subtraction CTA for the detection of aneurysm occlusion were 100% (95% CI, 82.41%-100%) and 100% (95% CI, 67.55%-100%), respectively. Agreement between readers was perfect (κ = 1.0). The smallest neck remnant detected on subtraction CTA was 1.2 mm. No complications occurred. CONCLUSIONS Subtraction CTA with single-electron metal artifact reduction is effective in the reduction of metal artifacts of flow diverters and might therefore be a viable alternative in the assessment of intracranial aneurysm occlusion after flow diverter treatment.
Collapse
Affiliation(s)
- M P Duarte Conde
- From the Departments of Neurosurgery (M.P.D.C., A.M.d.K., R.A., H.D.B., R.H.M.A.B., J.d.V.)
| | - A M de Korte
- From the Departments of Neurosurgery (M.P.D.C., A.M.d.K., R.A., H.D.B., R.H.M.A.B., J.d.V.)
| | | | - R Aquarius
- From the Departments of Neurosurgery (M.P.D.C., A.M.d.K., R.A., H.D.B., R.H.M.A.B., J.d.V.).,Pathology (R.A.), Radboud University Medical Center, Nijmegen, the Netherlands
| | - H D Boogaarts
- From the Departments of Neurosurgery (M.P.D.C., A.M.d.K., R.A., H.D.B., R.H.M.A.B., J.d.V.)
| | - R H M A Bartels
- From the Departments of Neurosurgery (M.P.D.C., A.M.d.K., R.A., H.D.B., R.H.M.A.B., J.d.V.)
| | - J de Vries
- From the Departments of Neurosurgery (M.P.D.C., A.M.d.K., R.A., H.D.B., R.H.M.A.B., J.d.V.)
| |
Collapse
|
16
|
Mocanu I, Van Wettere M, Absil J, Bruneau M, Lubicz B, Sadeghi N. Value of dual-energy CT angiography in patients with treated intracranial aneurysms. Neuroradiology 2018; 60:1287-1295. [DOI: 10.1007/s00234-018-2090-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Accepted: 08/23/2018] [Indexed: 10/28/2022]
|
17
|
Huhtakangas J, Lehecka M, Lehto H, Jahromi BR, Niemelä M, Kivisaari R. CTA analysis and assessment of morphological factors related to rupture in 413 posterior communicating artery aneurysms. Acta Neurochir (Wien) 2017; 159:1643-1652. [PMID: 28710522 DOI: 10.1007/s00701-017-3263-4] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Accepted: 06/27/2017] [Indexed: 10/19/2022]
Abstract
Posterior communicating artery (PcomA) aneurysms are frequently encountered, but there are few publications on their morphology. A growing number of aneurysms are incidental findings, which makes evaluation of rupture risk important. Our goal was to identify morphological features and anatomical variants associated with PComA aneurysms and to assess parameters related to rupture. We studied CT angiographies of 391 consecutive patients treated between 2000 and 2014 at a single institution. We determined clinically important morphological parameters and performed univariate and multivariate analysis. There were a total of 413 PComA aneurysms: 258 (62%) were ruptured and 155 (38%) unruptured. Ruptured PComA aneurysms had the potential to cause severe bleeding with IVH and/or temporal ICH (n = 170, 66% of ruptured). The main types of PComA origin were classified as follows: (1) separate (32%), (2) side by side (21%) and (3) a joint neck with the aneurysm (6%). After the multivariate logistic regression, the morphological parameters related to PComA aneurysm rupture were an irregular aneurysm dome, neck diameter, and aspect ratio >1.5. The most marked morphological features of the PComA aneurysms were: saccular nature (99%), infero-posterior dome orientation (42%), infrequency of large or giant aneurysms (4%), narrow neck compared to the aneurysm size, PComA originating directly from the aneurysm neck or the dome (28%), and fetal or dominant PComA on the side of the aneurysm (35%). There were location-related parameters that were more strongly associated with PComA aneurysm rupture than aneurysm size: an irregular aneurysm dome, larger diameter of the aneurysm neck and aspect ratio >1.5.
Collapse
|
18
|
Lin A, Rawal S, Agid R, Mandell DM. Cerebrovascular Imaging: Which Test is Best? Neurosurgery 2017; 83:5-18. [DOI: 10.1093/neuros/nyx325] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Accepted: 05/12/2017] [Indexed: 11/12/2022] Open
Abstract
Abstract
Optimal diagnosis and characterization of cerebrovascular disease requires selection of the appropriate imaging exam for each clinical situation. In this review, we focus on intracranial arterial disease and discuss the techniques in current clinical use for imaging the blood vessel lumen and blood vessel wall, and for mapping cerebral hemodynamic impairment at the tissue level. We then discuss specific strategies for imaging intracranial aneurysms, arteriovenous malformations, dural arterial venous fistulas, and arterial steno-occlusive disease.
Collapse
Affiliation(s)
- Amy Lin
- Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital and the University of Toronto, Toronto, Ontario, Canada
| | - Sapna Rawal
- Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital and the University of Toronto, Toronto, Ontario, Canada
| | - Ronit Agid
- Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital and the University of Toronto, Toronto, Ontario, Canada
| | - Daniel M Mandell
- Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital and the University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
19
|
Abdulazim A, Rubbert C, Reichelt D, Mathys C, Turowski B, Steiger HJ, Hänggi D, Etminan N. Dual- versus Single-Energy CT-Angiography Imaging for Patients Undergoing Intracranial Aneurysm Repair. Cerebrovasc Dis 2017; 43:272-282. [PMID: 28319953 DOI: 10.1159/000464356] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2016] [Accepted: 02/20/2017] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND The invasiveness and risk of thromboembolic complications of catheter angiography underline the need for alternative imaging modalities in patients following intracranial aneurysm (IA) repair. However, the overall image quality of existing noninvasive imaging modalities, such as single-energy CT angiography (SE-CTA), compromises its value in this respect. OBJECTIVE We prospectively investigated the value of a novel dual-energy CTA (DE-CTA) scanner and algorithm for assessing the degree of occlusion and parent vessel patency in patients following IA repair. METHODS A prospective cohort of 17 patients underwent DE-CTA imaging following surgical or endovascular IA repair. This dataset was matched with an identical historical cohort of 17 patients, who underwent IA repair and SE-CTA imaging. Beam-hardening artifacts, as a measure for objective imaging quality were analyzed based on the volume of a prolate ellipsoid, whereas subjective imaging quality at the IA site and corresponding parent vessels was rated by 2 independent neuroradiologists on a scale from 4 (excellent, no artifacts) to 1 (poor, severe artifacts). RESULTS Objective DE-CTA image quality was markedly higher, compared to SE-CTA in patients undergoing surgical (0.77 ± 0.23 vs. 10.91 ± 1.88 mL, respectively; p < 0.001) or endovascular (32.36 ± 10.62 vs. 107.63 ± 24.51 mL, respectively; p = 0.026) IA repair. Subjective image quality for DE-CTA was significantly improved compared to SE-CTA in the surgical group but not in the endovascular group. The calculated dose values for DE-CTA in our study remain markedly below the legally required radiation dose limits. CONCLUSION The imaging quality of DE-CTA, especially for patients undergoing surgical IA repair, is distinctly superior, compared to SE-CTA imaging. Therefore, DE-CTA may serve as a noninvasive alternative for assessing the IA occlusion rate and parent vessel patency.
Collapse
Affiliation(s)
- Amr Abdulazim
- Department of Neurosurgery, University Hospital Mannheim, University of Heidelberg, Mannheim, Germany
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Dehdashti AR, Chiluwal AK, Regli L. The Implication of Anterior Communicating Complex Rotation and 3-Dimensional Computerized Tomography Angiography Findings in Surgical Approach to Anterior Communicating Artery Aneurysms. World Neurosurg 2016; 91:34-42. [DOI: 10.1016/j.wneu.2016.03.051] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Revised: 03/15/2016] [Accepted: 03/17/2016] [Indexed: 11/29/2022]
|
21
|
Mohan S, Agarwal M, Pukenas B. Computed Tomography Angiography of the Neurovascular Circulation. Radiol Clin North Am 2016; 54:147-62. [DOI: 10.1016/j.rcl.2015.09.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
22
|
The Utility of Dual-Energy Computed Tomographic Angiography for the Evaluation of Brain Aneurysms After Surgical Clipping: A Prospective Study. World Neurosurg 2015; 84:1362-71. [DOI: 10.1016/j.wneu.2015.06.027] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2015] [Revised: 06/14/2015] [Accepted: 06/15/2015] [Indexed: 11/23/2022]
|
23
|
Ahmed O, Kalakoti P, Menger R, Brown B, Zhang S, Guthikonda B, Cuellar H. Accuracy of CT angiography in detection of blood supply dominance of posterior cerebral artery in patients with posterior communicating artery aneurysm. Neuroradiol J 2015; 28:598-603. [PMID: 26515748 DOI: 10.1177/1971400915615082] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND AND PURPOSE The use of computed tomography angiography (CTA) as the sole vascular imaging study for preoperative planning for clipping of aneurysms is well described in the literature. CTA is widely available, provides quick acquisition, has low morbidity, and low cost. In this study, we describe the accuracy of CTA in determining the blood supply dominance in comparison to standard digital subtraction angiography. MATERIALS AND METHODS Sixty-six patients, with both CTAs and angiograms, were reviewed by two independent neuroradiologists. The posterior cerebral artery was determined to have dominant supply from the posterior communicating artery if it was of similar size to the P2 segment and the P1 segment was smaller by approximately 50%. If the posterior communicating artery and P1 segment were the same size, it was considered to have a dual supply. If P1 and P2 segments were the same caliber and the posterior communicating artery was smaller by 50%, it was deemed to have posterior circulation dominance. RESULTS Based on the findings of our reviewers, CTA had a sensitivity and specificity of 69% and 96%, respectively, in predicting the presence of a fetal PCA. The positive predictive value was found to be 82% while a negative predictive value was estimated as 93%. A small-caliber P1 segment and large-caliber posterior communicating artery led to inaccurate interpretations of the CTAs. CONCLUSION This study shows that one cannot accurately predict blood supply dominance of the posterior cerebral artery. Knowledge of the blood flow dominance is essential when clipping a posterior communicating artery aneurysm to avoid compromise in posterior circulation.
Collapse
Affiliation(s)
- Osama Ahmed
- Louisiana State University Health Science Center, USA
| | | | | | | | - Shihao Zhang
- Louisiana State University Health Science Center, USA
| | | | - Hugo Cuellar
- Louisiana State University Health Science Center, USA
| |
Collapse
|
24
|
Treatment outcomes of surgical clipping for unruptured anterior circulation aneurysm—single institute experiences in the era of neurophysiologic monitoring and endovascular treatment. Neurosurg Rev 2015; 38:677-82. [DOI: 10.1007/s10143-015-0642-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2013] [Revised: 11/24/2014] [Accepted: 01/19/2015] [Indexed: 11/27/2022]
|
25
|
Gölitz P, Struffert T, Ganslandt O, Lang S, Knossalla F, Doerfler A. Contrast-enhanced angiographic computed tomography for detection of aneurysm remnants after clipping: a comparison with digital subtraction angiography in 112 clipped aneurysms. Neurosurgery 2015; 74:606-13; discussion 613-4. [PMID: 24584137 DOI: 10.1227/neu.0000000000000326] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND For preclusion of remnants after aneurysm clipping, a reliable, noninvasive imaging technique is desirable. OBJECTIVE To evaluate the reliability of optimized angiographic computed tomography with intravenous contrast agent injection (ivACT) in detecting remnants after aneurysmal clipping compared with digital subtraction angiography (DSA), the gold standard. METHODS We included 84 patients with 112 clipped cerebral aneurysms of the anterior circulation. For treatment, 116 clips of cobalt and 57 clips of titanium alloy were used. In each patient, we performed an ivACT with dual rotational acquisition and a DSA. Data from ivACT were postprocessed with a dual-volume technique with newly implemented reconstructions modes. Aneurysm remnants were measured, classified, and correlated with DSA by 2 raters. RESULTS In total, 12 remnants were revealed by DSA, meaning a prevalence of 11%. IvACT demonstrated a sensitivity of 75% to 92% and a specificity of 99% in detecting remnants up to a minimal size of 0.7 × 0.3 mm. Classification of remnants by ivACT was identical to that by DSA, and assessment of size showed a significant correlation with DSA (P < .001). No significant differences between cobalt and titanium alloy were revealed concerning artifacts. CONCLUSION Optimized ivACT with enhanced postprocessing demonstrated high sensitivity and specificity in detecting remnants after aneurysm clipping in the anterior circulation. Classification and assessment of remnant size and detection of relevant parent artery stenosis showed high accuracy of ivACT compared with DSA. Our results indicate that ivACT might become a noninvasive alternative to DSA for postsurgical control.
Collapse
Affiliation(s)
- Philipp Gölitz
- *Department of Neuroradiology, ‡Department of Neurosurgery, §Department of Neurology, University of Erlangen-Nuremberg, Erlangen, Germany
| | | | | | | | | | | |
Collapse
|
26
|
de Oliveira Manoel AL, Mansur A, Murphy A, Turkel-Parrella D, Macdonald M, Macdonald RL, Montanera W, Marotta TR, Bharatha A, Effendi K, Schweizer TA. Aneurysmal subarachnoid haemorrhage from a neuroimaging perspective. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2014; 18:557. [PMID: 25673429 PMCID: PMC4331293 DOI: 10.1186/s13054-014-0557-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
Abstract
Neuroimaging is a key element in the management of patients suffering from subarachnoid haemorrhage (SAH). In this article, we review the current literature to provide a summary of the existing neuroimaging methods available in clinical practice. Noncontrast computed tomography is highly sensitive in detecting subarachnoid blood, especially within 6 hours of haemorrhage. However, lumbar puncture should follow a negative noncontrast computed tomography scan in patients with symptoms suspicious of SAH. Computed tomography angiography is slowly replacing digital subtraction angiography as the first-line technique for the diagnosis and treatment planning of cerebral aneurysms, but digital subtraction angiography is still required in patients with diffuse SAH and negative initial computed tomography angiography. Delayed cerebral ischaemia is a common and serious complication after SAH. The modern concept of delayed cerebral ischaemia monitoring is shifting from modalities that measure vessel diameter to techniques focusing on brain perfusion. Lastly, evolving modalities applied to assess cerebral physiological, functional and cognitive sequelae after SAH, such as functional magnetic resonance imaging or positron emission tomography, are discussed. These new techniques may have the advantage over structural modalities due to their ability to assess brain physiology and function in real time. However, their use remains mainly experimental and the literature supporting their practice is still scarce.
Collapse
|
27
|
Assessment of long-term results of intracranial aneurysm clipping by means of computed tomography angiography. Neurol Neurochir Pol 2013; 47:18-26. [PMID: 23487290 DOI: 10.5114/ninp.2012.31549] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND AND PURPOSE The aim of this retrospective study was to assess the effectiveness of aneurysm clipping by computed tomography angiography (CTA) in a long-term follow-up. MATERIAL AND METHODS The CTA examination was performed in 119 patients who had 143 aneurysms clipped. The examinations were performed 3 to 11 years (mean 6 years) after clipping using a GE Lightspeed PRO16 scanner. RESULTS In all cases but one, good quality CTA images, suitable for evaluation of the arteries around the clip site, were obtained. Complete aneurysm closure without neck remnant or regrowth was confirmed in 137 (96%) aneurysms. In 4 (3%) cases, neck remnants were detected (2 on the anterior communicating artery [AComA] and 2 on the middle cerebral artery [MCA]). A total clip slippage from the aneurysm dome was revealed in 1 case. One case of aneurysm re-rupture was noted, 11 years after clipping. The rebleeding was caused by AComA aneurysm regrowth. Among these 6 patients with unsatisfactory clipping, 2 required further treatment and 4 remain under observation. Nineteen 'de novo' aneurysms in other locations were found in 14 (12%) patients. Summing up all of the pathological findings in the study group, there were 18 (15%) patients who needed further management including close surveillance or re-treatment. CONCLUSIONS Computed tomography angiography is a simple and reliable method of aneurysm clipping evaluation. The long- term follow-up CTA confirmed the permanent and complete obliteration of 96% of the aneurysms. The rate of unsatisfactory aneurysm closure was 4%, but only 1.4% needed re-treatment during a mean follow-up of 6 years. The annual risk of aneurysm re-rupture was 0.1%.
Collapse
|
28
|
Wong JM, Ziewacz JE, Ho AL, Panchmatia JR, Kim AH, Bader AM, Thompson BG, Du R, Gawande AA. Patterns in neurosurgical adverse events: open cerebrovascular neurosurgery. Neurosurg Focus 2013; 33:E15. [PMID: 23116095 DOI: 10.3171/2012.7.focus12181] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT As part of a project to devise evidence-based safety interventions for specialty surgery, we sought to review current evidence concerning the frequency of adverse events in open cerebrovascular neurosurgery and the state of knowledge regarding methods for their reduction. This review represents part of a series of papers written to consolidate information about these events and preventive measures as part of an ongoing effort to ascertain the utility of devising system-wide policies and safety tools to improve neurosurgical practice. METHODS The authors performed a PubMed search using search terms "cerebral aneurysm", "cerebral arteriovenous malformation", "intracerebral hemorrhage", "intracranial hemorrhage", "subarachnoid hemorrhage", and "complications" or "adverse events." Only papers that specifically discussed the relevant complication rates were included. Papers were chosen to be included to maximize the range of rates of occurrence for the reported adverse events. RESULTS The review revealed hemorrhage-related hyperglycemia (incidence rates ranging from 27% to 71%) and cerebral salt-wasting syndromes (34%-57%) to be the most common perioperative adverse events related to subarachnoid hemorrhage (SAH). Next in terms of frequency was new cerebral infarction associated with SAH, with a rate estimated at 40%. Many techniques are advocated for use during surgery to minimize risk of this development, including intraoperative neurophysiological monitoring, but are not universally used due to surgeon preference and variable availability of appropriate staffing and equipment. The comparative effectiveness of using or omitting monitoring technologies has not been evaluated. The incidence of perioperative seizure related to vascular neurosurgery is unknown, but reported seizure rates from observational studies range from 4% to 42%. There are no standard guidelines for the use of seizure prophylaxis in these patients, and there remains a need for prospective studies to support such guidelines. Intraoperative rupture occurs at a rate of 7% to 35% and depends on aneurysm location and morphology, history of rupture, surgical technique, and surgeon experience. Preventive strategies include temporary vascular clipping. Technical adverse events directly involving application of the aneurysm clip include incomplete aneurysm obliteration and parent vessel occlusion. The rates of these events range from 5% to 18% for incomplete obliteration and 3% to 12% for major vessel occlusion. Intraoperative angiography is widely used to confirm clip placement; adjuncts include indocyanine green video angiography and microvascular Doppler ultrasonography. Use of these technologies varies by institution. DISCUSSION A significant proportion of these complications may be avoidable through development and testing of standardized protocols to incorporate monitoring technologies and specific technical practices, teamwork and communication, and concentrated volume and specialization. Collaborative monitoring and evaluation of such protocols are likely necessary for the advancement of open cerebrovascular neurosurgical quality.
Collapse
Affiliation(s)
- Judith M Wong
- Department of Health Policy and Management, Harvard School of Public Health, Brigham and Women’s Hospital, Street, Boston, Massachusetts 02115, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Impact of a new metal artefact reduction algorithm in the noninvasive follow-up of intracranial clips, coils, and stents with flat-panel angiographic CTA: initial results. Neuroradiology 2013; 55:813-8. [PMID: 23588613 DOI: 10.1007/s00234-013-1165-6] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2012] [Accepted: 03/01/2013] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Flat-panel angiographic CT after intravenous contrast agent application (ivACT) is increasingly used as a follow-up examination after coiling, clipping, or stenting. The purpose of this study was to evaluate the feasibility of a new metal artefact reduction algorithm (MARA) in patients treated for intracranial aneurysms and stenosis. METHODS IvACT was performed on a flat-panel detector angiography system after intravenous application of 80 ml contrast media. The uncorrected raw images were transferred to a prototype reconstruction workstation where the MARA was applied. Two experienced neuroradiologists examined the corrected and uncorrected images on a commercially available workstation. RESULTS Artefacts around the implants were detected in all 16 uncorrected cases, while eight cases showed remaining artefacts after correction with the MARA. In the cases without correction, there were 11 cases with "extensive" artefacts and five cases with "many" artefacts. After correction, seven cases showed "few" and only one case "many" artefacts (Wilcoxon test, P < 0.001). Parent vessels were characterized as "not identifiable" in 62% of uncorrected images, while the delineation of parent vessels were classified as "excellent" in 50% of the cases after correction (Wilcoxon test, P = 0.001). CONCLUSIONS Use of the MARA in our study significantly reduced artefacts around metallic implants on ivACT images and allowed for the delineation of surrounding structures.
Collapse
|
30
|
Gölitz P, Struffert T, Ganslandt O, Saake M, Lücking H, Rösch J, Knossalla F, Doerfler A. Optimized angiographic computed tomography with intravenous contrast injection: an alternative to conventional angiography in the follow-up of clipped aneurysms? J Neurosurg 2012; 117:29-36. [PMID: 22519433 DOI: 10.3171/2012.3.jns111895] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
OBJECT The purpose of this study was to evaluate the diagnostic accuracy of an optimized angiographic CT (ACT) program with intravenous contrast agent injection (ivACT) in the assessment of potential aneurysm remnants after neurosurgical clipping compared with conventional digital subtraction angiography (DSA). METHODS The authors report on 14 patients with 19 surgically clipped cerebral aneurysms who were scheduled to undergo angiographic follow-up. For each patient, the authors performed ivACT with dual rotational acquisition and conventional angiography including a 3D rotational run. The ivACT and 3D DSA data were reconstructed with different imaging modes, including a newly implemented subtraction mode with motion correction. Thereafter, the data sets were merged by the dual-volume technique, and freely rotatable 3D images were obtained for further analysis. Observed aneurysm remnants were electronically measured and classified for each modality by 2 experienced neuroradiologists. RESULTS Digital subtraction angiography and ivACT both provided high-quality images without motion artifacts. Artifact disturbances from the aneurysm clips led to a compromised, but still sufficient, image quality in 1 case. The ivACT assessed all aneurysm remnants as true-positive up to a minimal size of 2.6×2.4 mm in accordance with the DSA findings. There was a tendency for ivACT to overestimate the size of the aneurysm remnants. All cases without aneurysm remnants on DSA were scored correctly as true-negative by ivACT. CONCLUSIONS By using an optimized image acquisition protocol as well as enhanced postprocessing algorithms, the noninvasive ivACT seems to achieve results comparable to those of conventional angiography in the follow-up of clipped cerebral aneurysms. The authors have shown that ivACT can provide reliable diagnostic information about potential aneurysm remnants after neurosurgical clipping with high sensitivity and specificity, sufficient for clinical decision making, at least for aneurysms in the anterior circulation located distal to the internal carotid artery. These preliminary results may be a promising step to replace conventional angiography by a noninvasive imaging technique in selected cases after aneurysm clipping.
Collapse
Affiliation(s)
- Philipp Gölitz
- Department of Neuroradiology, University of Erlangen-Nuremberg, Erlangen, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Bacigaluppi S, Fontanella M, Manninen P, Ducati A, Tredici G, Gentili F. Monitoring techniques for prevention of procedure-related ischemic damage in aneurysm surgery. World Neurosurg 2011; 78:276-88. [PMID: 22381314 DOI: 10.1016/j.wneu.2011.11.034] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2011] [Revised: 10/05/2011] [Accepted: 11/22/2011] [Indexed: 12/24/2022]
Abstract
OBJECTIVE To describe the application of intraoperative monitoring techniques during aneurysm surgery and to discuss the advantages and limitations of these techniques in prevention of postoperative neurologic deficits. METHODS Articles found in the literature through PubMed for the time frame 1980-2011 and the authors' personal files were reviewed. RESULTS Various techniques for detection of vascular insufficiency are available, including direct methods to measure cerebral blood flow and indirect methods to evaluate the integrity of neurologic pathways. CONCLUSIONS The choice of monitoring modality should be governed by the vessel and by the vascular territory most at risk during the planned procedure with proper awareness of the potential limits related to each technique. Aneurysm surgery monitoring should help to address issues of continuity and provide a morphologic and functional assessment. Although the use of monitoring devices is still not routine in aneurysm surgery and no standards have been established, combining different monitoring techniques is crucial to optimize aneurysm surgery and avoid or minimize complications.
Collapse
Affiliation(s)
- Susanna Bacigaluppi
- Department of Neurosciences and Biomedical Technologies, University of Milano Bicocca, Monza, Italy.
| | | | | | | | | | | |
Collapse
|
32
|
Psychogios MN, Wachter D, Mohr A, Schramm P, Frölich AM, Jung K, Rohde V, Knauth M. Feasibility of flat panel angiographic CT after intravenous contrast agent application in the postoperative evaluation of patients with clipped aneurysms. AJNR Am J Neuroradiol 2011; 32:1956-62. [PMID: 21852377 DOI: 10.3174/ajnr.a2611] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND AND PURPOSE Important findings, such as aneurysm remnants or major arterial occlusion, can be detected on intra- or postoperative angiography after surgical clipping of intracranial aneurysms. The purpose of this study was to evaluate the feasibility of IV-ACT for the postoperative detection of residual aneurysms and parent vessel patency compared with IA-DSA, which was selected as the standard reference method. MATERIALS AND METHODS Twenty-two patients with 27 aneurysms treated by surgical clipping were examined by using both IA-DSA and IV-ACT. Both diagnostic procedures were performed on an FPD-equipped angiography system. Postprocessing of IV-ACT acquisitions was performed on a dedicated workstation producing multiplanar reformations and maximum intensity projections of the clip region and other intracranial arteries. Three interventional neuroradiologists independently evaluated both procedures. RESULTS A residual aneurysm was delineated in 10 cases with IA-DSA. Sufficient opacification of the intracranial vessels was assigned in 26 IV-ACT cases. Due to metal artifacts, IV-ACT images were tagged as "not diagnostic" on 8 occasions. In the other 19 aneurysms, a residual aneurysm was delineated in 6 cases-all 6 being true-positive compared with IA-DSA-and was excluded in the remaining 13 cases-all true-negative. Even small aneurysm remnants with a diameter of 1.5 mm were detected with IV-ACT. CONCLUSIONS Currently IV-ACT cannot be recommended as a routine tool for postoperative evaluation of clipped aneurysms due to metal artifacts in 30% of the examinations. These artifacts appear with multiple normal-sized or large clips. In patients with single or multiple small clips, IV-ACT can reliably show aneurysm remnants.
Collapse
Affiliation(s)
- M-N Psychogios
- Department of Neuroradiology, University Medicine Goettingen, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
33
|
The value of dual-energy CTA for control of surgically clipped aneurysms. Eur Radiol 2011; 21:2193-201. [DOI: 10.1007/s00330-011-2147-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2011] [Revised: 04/10/2011] [Accepted: 04/27/2011] [Indexed: 12/27/2022]
|
34
|
Tomura N, Sakuma I, Otani T, Nisii T, Sugawara M, Koga M, Takahashi S, Yanagisawa T, Mizoi K. Evaluation of Postoperative Status after Clipping Surgery in Patients with Cerebral Aneurysm on 3-Dimensional-CT Angiography with Elimination of Clips. J Neuroimaging 2010; 21:10-5. [DOI: 10.1111/j.1552-6569.2009.00435.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
35
|
El Beltagy M, Muroi C, Roth P, Fandino J, Imhof HG, Yonekawa Y. Recurrent Intracranial Aneurysms After Successful Neck Clipping. World Neurosurg 2010; 74:472-7. [DOI: 10.1016/j.wneu.2010.06.036] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2009] [Accepted: 06/17/2010] [Indexed: 10/18/2022]
|
36
|
Sadatsafavi M, Marra C, Li D, Illes J. An ounce of prevention is worth a pound of cure: a cost-effectiveness analysis of incidentally detected aneurysms in functional MRI research. VALUE IN HEALTH : THE JOURNAL OF THE INTERNATIONAL SOCIETY FOR PHARMACOECONOMICS AND OUTCOMES RESEARCH 2010; 13:761-9. [PMID: 20561317 PMCID: PMC10517630 DOI: 10.1111/j.1524-4733.2010.00755.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
PURPOSE Despite ongoing debate about best practices for managing incidentally detected findings in brain research studies using magnetic resonance imaging (MRI), this issue has not been investigated from a health economics viewpoint. We applied a decision-analytic approach to assess the benefit of various strategies for functional MRI (fMRI) studies using intracranial aneurysms (IA) as a model. METHODS A decision tree and Markov model were created to simulate the impact on the lifetime costs and quality-adjusted life-years (QALY) of four different strategies for review of scans for the presence of IA. To populate the decision model, we used current evidence from the literature and results from a survey of experts. RESULTS Review of the anatomical scans by a nonspecialist is not cost-effective in any of the subgroups of participants. Full clinical examination of women with a positive family history before enrollment in a study is cost-effective. Cost-effectiveness of reviewing scans obtained from women without a family history and men with a positive family history of IA depends on the willingness-to-pay (λ) for a QALY: at λ of $50,000/QALY, review of scans by a specialist is cost-effective, whereas at λ of $100,000/QALY, a full clinical workup is the best option. Compared with not reviewing any scans, a customized strategy for each subgroup of participants results in an incremental cost-effectiveness ratio of $12,503 for λ=$50,000/QALY and $32,767 for λ=$100,000/QALY. CONCLUSION Tailored strategies based on the characteristics of research participants and λ for one QALY are needed to address the problem of incidental findings in research fMRI studies.
Collapse
Affiliation(s)
- Mohsen Sadatsafavi
- Collaboration for Outcome Research and Evaluation, Faculty of Pharmaceutical Sciences,The University of British Columbia,Vancouver, BC, Canada
| | - Carlo Marra
- Collaboration for Outcome Research and Evaluation, Faculty of Pharmaceutical Sciences,The University of British Columbia,Vancouver, BC, Canada
| | - David Li
- Department of Radiology and Division of Neurology, Department of Medicine, Faculty of Medicine,The University of British Columbia,Vancouver, BC, Canada
| | - Judy Illes
- Division of Neurology, Department of Medicine,The University of British Columbia,Vancouver, BC, Canada
| |
Collapse
|
37
|
Thines L, Dehdashti AR, Howard P, Costa LD, Wallace MC, Willinsky RA, Tymianski M, Lejeune JP, Agid R. Postoperative Assessment of Clipped Aneurysms With 64-Slice Computerized Tomography Angiography. Neurosurgery 2010; 67:844-53; discussion 853-4. [DOI: 10.1227/01.neu.0000374684.10920.a2] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Abstract
BACKGROUND
Multidetector computerized tomography angiography (MDCTA) is now a widely accepted technique for the management of intracranial aneurysms.
OBJECTIVE
To evaluate its accuracy for the postoperative assessment of clipped intracranial aneurysms.
METHODS
We analyzed a consecutive series of 31 patients that underwent direct surgical clipping procedures of 38 aneurysms. A 64 slice MDCT scanner (Aquilion 64, Toshiba) was used and results were compared with digital subtraction angiographies (DSA). Two independent neuroradiologists analyzed the following data: examination quality, artifacts, aneurysm remnant, and patency of collateral branches. Interobserver agreement, sensitivity, and specificity were calculated.
RESULTS
Seventy-nine percent of the aneurysms were located in the anterior circulation. Significant artifacts were found with multiple and cobalt-alloy clips. According to DSA, remnants >2 mm were found in 21% of the cases, and 2 patients had one collateral branch occluded. Sensitivity and specificity of 64-MDCTA for the detection of aneurysm remnants were 50% and 100%, respectively. Sensitivity and specificity of 64-MDCTA for the detection of a significant remnant (>2 mm) and the detection of the occlusion of a collateral branch were, respectively, 67% and 100% and 50% and 100%. No relationship was found with the location, type, shape, size, or number of clips, but missed remnants tended to be larger with cobalt-alloy clips.
CONCLUSIONS
64-MDCTA is a valuable technique to assess the presence of a significant postoperative remnant in single titanium clip application cases and might be useful for long-term follow-up. DSA remains the most accurate postoperative radiological examination.
Collapse
Affiliation(s)
- Laurent Thines
- Department of Neurosurgery, Lille University Hospital, Lille, France
- Division of Neurosurgery, Department of Surgery, University of Toronto Brain Vascular Malformation Study Group, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Amir R. Dehdashti
- Division of Neurosurgery, Department of Surgery, University of Toronto Brain Vascular Malformation Study Group, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Peter Howard
- Division of Neuroradiology, Department of Medical Imaging, University of Toronto Brain Vascular Malformation Study Group, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Leodante Da Costa
- Division of Neuroradiology, Department of Medical Imaging, University of Toronto Brain Vascular Malformation Study Group, Toronto Western Hospital, Toronto, Ontario, Canada
| | - M. Christopher Wallace
- Division of Neurosurgery, Department of Surgery, University of Toronto Brain Vascular Malformation Study Group, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Robert A. Willinsky
- Division of Neuroradiology, Department of Medical Imaging, University of Toronto Brain Vascular Malformation Study Group, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Michael Tymianski
- Division of Neurosurgery, Department of Surgery, University of Toronto Brain Vascular Malformation Study Group, Toronto Western Hospital, Toronto, Ontario, Canada
| | - Jean-Paul Lejeune
- Department of Neurosurgery, Lille University Hospital, Lille, France
| | - Ronit Agid
- Division of Neuroradiology, Department of Medical Imaging, University of Toronto Brain Vascular Malformation Study Group, Toronto Western Hospital, Toronto, Ontario, Canada
| |
Collapse
|
38
|
Marshall SA, Kathuria S, Nyquist P, Gandhi D. Noninvasive imaging techniques in the diagnosis and management of aneurysmal subarachnoid hemorrhage. Neurosurg Clin N Am 2010; 21:305-23. [PMID: 20380972 DOI: 10.1016/j.nec.2009.10.005] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Aneurysmal subarachnoid hemorrhage (aSAH) is a devastating condition, requiring prompt diagnosis and therapeutic intervention as well as close monitoring for the development of complications including vasospasm (VS). Although digital subtraction angiography is still considered the gold standard for the diagnosis of aSAH (and vasospasm), new and less invasive modalities are emerging including ultrasound, CT, CT angiography and CT perfusion, and MR imaging. The current evidence for the use of these newer modalities is described for the diagnosis of aSAH and the management of its sequelae including VS.
Collapse
Affiliation(s)
- Scott A Marshall
- Division of Neurosciences Critical Care, Department of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, 600 North Wolfe Street, Baltimore, MD 21287, USA
| | | | | | | |
Collapse
|
39
|
Comparison of computed tomography angiography with digital subtraction angiography in the assessment of clipped intracranial aneurysms. J Comput Assist Tomogr 2010; 34:440-5. [PMID: 20498551 DOI: 10.1097/rct.0b013e3181d27393] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To examine whether computed tomography angiography (CTA) is comparable to digital subtraction angiography (DSA) in assessing clipped intracranial aneurysms. MATERIALS AND METHODS Retrospective collection of clipped aneurysms that had both CTA and DSA within 2 months of one another. Computed tomography angiograms were independently reviewed by 2 blinded neuroradiologists; rereviewed by one at least 4 months later. Each was classified as complete obliteration, neck remnant, or residual aneurysm. Parent vessel was classified as patent or occluded. Digital subtraction angiograms were reviewed in a similar manner by a third blinded neuroradiologist. RESULTS Forty-eight patients with 53 clipped aneurysms were collected. On DSA, 35 were completely obliterated, 10 neck remnants, and 8 residual aneurysms. The ability of CTA to detect residual aneurysms versus complete obliterations or neck remnants was excellent (mean sensitivity, 88%; specificity, 100%; positive predictive value [PPV], 100%; negative predictive value [NPV], 98%). The ability of CTA to detect neck remnants versus complete obliterations was poor (mean sensitivity, 20%; specificity, 99%; PPV, 83%; NPV, 81%). The CTAs were good at detecting parent vessel occlusion (mean sensitivity, 88%; specificity, 97%; PPV, 75%; NPV, 99%). Interrater and intrarater agreement was good to excellent for aneurysm and parent vessel assessment, with kappa values ranging from 0.6 to 1.0. CONCLUSIONS Computed tomography angiography has high sensitivity and specificity for residual aneurysm detection and parent vessel occlusion. It is not accurate in neck remnant detection, although these were small and of uncertain clinical significance. This suggests that CTA is useful for follow-up of clipped aneurysms. However, given the potential to miss neck remnants or small residual aneurysms, it is recommended to perform initial DSA and CTA to select cases in which CTA follow-up is appropriate.
Collapse
|
40
|
Zachenhofer I, Cejna M, Schuster A, Donat M, Roessler K. Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology. Clin Neurol Neurosurg 2010; 112:386-91. [DOI: 10.1016/j.clineuro.2010.02.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2009] [Revised: 09/07/2009] [Accepted: 02/03/2010] [Indexed: 11/17/2022]
|
41
|
Usefulness of multislice computerized tomographic angiography in the postoperative evaluation of patients with clipped aneurysms. Acta Neurochir (Wien) 2010; 152:793-802. [PMID: 19639249 DOI: 10.1007/s00701-009-0465-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2008] [Accepted: 07/04/2009] [Indexed: 11/27/2022]
Abstract
BACKGROUND The aim of our study was to evaluate the diagnostic efficacy of multislice computed tomographic angiography (MSCTA) regarding exclusion quality after aneurysm clipping. METHODS Sixty patients (74 aneurysms) underwent microsurgical exclusion using titanium clips. The presence of aneurysm remnants on MSCTA was compared by a neuroradiologist to 2D digital subtraction angiography (DSA), which was considered as a reference examination. The contribution of 3D DSA was assessed in a subpopulation of 29 patients (35 aneurysms). RESULTS With 2D DSA, six aneurysm remnants (8%) were diagnosed, and only five (7%) by MSCTA. The specificity and sensitivity were 98.5 and 83%, respectively. MSCTA failed to demonstrate one large remnant (>2 mm) because of clip artifacts (six clips). With 3D DSA six supplementary remnants were diagnosed. Two were large remnants blinded by vessel overlaps and clip artifacts. Four were small "dog-eared" remnants (< or =2 mm). No additional treatment was required for small remnants. CONCLUSION In the postoperative period, MSCTA was considered a useful tool to evaluate the large remnants as well as a non-invasive ulterior examination for suspected bifurcation. Nevertheless, 3D DSA is still required for an accurate evaluation of aneurysms treated by more than three clips.
Collapse
|
42
|
A Stijntje E Bor, Marieke JH Wermer, Gabriel JE Rinkel. Unruptured intracranial aneurysms: initial and follow-up screening. FUTURE NEUROLOGY 2010. [DOI: 10.2217/fnl.10.17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Subarachnoid hemorrhage (SAH) from a ruptured intracranial aneurysm is a devastating disease that causes death or severe disability in half of patients. Intracranial aneurysms are not present at birth but develop during life. Actively searching and treating intracranial aneurysms before rupture may prevent SAH as a result of these aneurysms. The prevalence of intracranial aneurysms is approximately 2% in the general population, but higher in subgroups such as patients who have survived an episode of SAH, persons with a family history of SAH and patients with polycystic kidney disease. Screening for intracranial aneurysms should be considered in these high-risk groups. Some of the intracranial aneurysms detected with screening will be too small to be treated, and may therefore be followed over time, which can cause anxiety in the patient. In this article, we discuss current knowledge, remaining questions and future perspectives in screening and follow-up imaging for unruptured intracranial aneurysms.
Collapse
|
43
|
Ahn SS, Kim YD. Three-dimensional digital subtraction angiographic evaluation of aneurysm remnants after clip placement. J Korean Neurosurg Soc 2010; 47:185-90. [PMID: 20379470 DOI: 10.3340/jkns.2010.47.3.185] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2009] [Revised: 12/31/2009] [Accepted: 01/31/2010] [Indexed: 11/27/2022] Open
Abstract
OBJECTIVE The aneurysm remnants rate was evaluated via three-dimensional digital subtraction angiography (3D-DSA) in the postoperative evaluation of clipped aneurysms. METHODS Data on surgically clipped aneurysms of anterior circulation obtained via postoperative 3D-DSA from February 2007 to March 2009 were gathered. The results of the postoperative 3D-DSA and of two-dimensional digital subtraction angiography (2D-DSA) for the detection of aneurysm remnants were compared, and an investigation was performed as to why 2D-DSA had missed some aneurysm remnants that were detected in the 3D-DSA. Various surgical factors that revealed aneurysm remnants in the 3D-DSA were also evaluated. RESULTS A total of 39 neck remnants of 202 clipped aneurysms (19.3%) were confirmed in 3D-DSA, and these were classified according to Sindou's classification of aneurysm remnants. Patients with only a neck remnant found in the 3D-DSA represented 17.3% (35/202 aneurysms) of the whole series, and those with a residuum of neck plus sac found in the 3D-DSA represented 1.9% (4/202 aneurysms). The causes of aneurysm remnants were no full visualization (14/39, 35.9%), parent and perforator artery protection (10/39, 25.6%), clip design problems (8/39, 20.5%), and broad-necked aneurysm (7/39, 17.9%). CONCLUSION Patients with </= 2 mm aneurysm remnants showed an increased risk of undetectable aneurysm remnants in the 2D-DSA. The most frequent location of the missed aneurysm in 2D-DSA was the anterior communicating artery. 3D-DSA showed more aneurysm remnants than what is indicated in the existing literature, the 2D-DSA.
Collapse
Affiliation(s)
- Soon-Seob Ahn
- Department of Neurosurgery, Daegu Catholic University College of Medicine, Daegu, Korea
| | | |
Collapse
|
44
|
Delgado Almandoz JE, Romero JM, Pomerantz SR, Lev MH. Computed Tomography Angiography of the Carotid and Cerebral Circulation. Radiol Clin North Am 2010; 48:265-81, vii-viii. [DOI: 10.1016/j.rcl.2010.02.007] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
45
|
Jamshidi S, Kandiah PA, Singhal AB, Resnick JB, Furie KL, Borczuk P, Parry BA, Lev M, Koroshetz WJ, Chang Y, Nagurney JT. Clinical predictors of significant findings on head computed tomographic angiography. J Emerg Med 2009; 40:469-75. [PMID: 19854018 DOI: 10.1016/j.jemermed.2009.08.021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2009] [Revised: 05/31/2009] [Accepted: 08/29/2009] [Indexed: 10/20/2022]
Abstract
BACKGROUND Although head computed tomographic angiography (CTA) is a sensitive tool for the evaluation of neurological symptoms in the emergency department (ED), little is known about which clinical signs predict significant CTA findings. OBJECTIVES To identify clinical factors that predict significant findings on head CTA in patients presenting to the ED with neurological complaints. METHODS Retrospective chart review of consecutive adult patients undergoing head CTA over a 6-month period in an urban, tertiary care ED with an annual volume of 76,000. Significant head CTA findings were defined as clinically significant neurological abnormalities undetected by previous imaging studies. Demographics, chief complaint, results of the neurological examinations (NE), and head non-contrast computed tomography (CT) results were used as predictors of significant head CTA. All predictors with a univariate p < 0.2 using Pearson's chi-squared were entered stepwise into a multivariable logistic regression including odds ratios (OR), with inclusion restricted to p < 0.05. RESULTS Chart review yielded 456 cases; 215 (47%) were male. Mean age was 62 (SD 20) years. There were 189 patients (41%) with abnormal CTAs. Multivariable logistic regression indicated five variables that predicted a clinically significant CTA: abnormal CT (OR 3.72), chief complaint of subarachnoid hemorrhage-type headache (OR 2.30), and motor deficit (OR 2.23), visual deficit (OR 2.23), and other focal deficit (OR 2.18) on NE. A chief complaint of trauma (OR 0.23) predicted a normal CTA. CONCLUSIONS Specific historical and focal neurological findings are useful for predicting clinically significant findings on head CTA.
Collapse
Affiliation(s)
- Soheil Jamshidi
- Department of Emergency Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Chen W, Yang Y, Qiu J, Peng Y, Xing W. Sixteen-row multislice computerized tomography angiography in the postoperative evaluation of patients with intracranial aneurysms. Br J Neurosurg 2009; 22:63-70. [DOI: 10.1080/02688690701630108] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
47
|
Chen W, Yang Y, Qiu J, Peng Y, Xing W. Clinical application of 16-row multislice computed tomographic angiography in the preoperative and postoperative evaluation of intracranial aneurysms for surgical clipping. ACTA ACUST UNITED AC 2009; 71:559-65. [DOI: 10.1016/j.surneu.2008.05.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2007] [Accepted: 05/13/2008] [Indexed: 11/29/2022]
|
48
|
Dashti R, Laakso A, Niemelä M, Porras M, Hernesniemi J. Microscope-integrated near-infrared indocyanine green videoangiography during surgery of intracranial aneurysms: the Helsinki experience. ACTA ACUST UNITED AC 2009; 71:543-50; discussion 550. [PMID: 19328531 DOI: 10.1016/j.surneu.2009.01.027] [Citation(s) in RCA: 120] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2008] [Accepted: 01/28/2009] [Indexed: 10/21/2022]
Abstract
BACKGROUND Microscope-integrated near-infrared indocyanine green videoangiography (ICG-VA) is a new method of intraoperative blood flow assessment. The objective of this study was to evaluate the reliability of this technique in the evaluation of neck residuals and patency of branches after microneurosurgical clipping of intracranial aneurysms (IAs). METHODS During a period of 14 months, between November 2005 and December 2006, 289 patients with intracranial aneurysms were operated on in our institution. Intraoperative ICG-VA was performed during microneurosurgical clipping of 239 IAs in 190 patients. Postoperative computed tomography and computed tomography angiography (CTA) were performed for all patients. Intraoperative interpretation of ICG-VA in assessing the neck residual or the patency of vessels after clipping of each single aneurysm were recorded and correlated with postoperative CTA and/or digital subtraction angiography. RESULTS Postoperative imaging studies revealed no incomplete occlusions of aneurysm domes. Unexpected neck residuals were observed in 14 aneurysms (6%). There were no parent artery occlusions. Unexpected branch occlusions including both major and minor branching arteries were observed in 15 aneurysms (6%). CONCLUSIONS Indocyanine green videoangiograph is a simple and fast method of blood flow assessment with acceptable reliability. Indocyanine green videoangiograph can provide real-time information to assess blood flow in vessels of different size as well as the occlusion of the aneurysm. Intraoperative assessment of blood flow in the perforating branches is one of the most important advantages. In selected cases such as giant, complex, and deep-sited aneurysms or when the quality of image in ICG-VA is not adequate, other methods of intraoperative blood flow assessment should be considered.
Collapse
Affiliation(s)
- Reza Dashti
- Department of Neurosurgery, Helsinki University Central Hospital, 00260, Helsinki, Finland
| | | | | | | | | |
Collapse
|
49
|
Assessment of extracranial–intracranial bypass patency with 64-slice multidetector computerized tomography angiography. Neuroradiology 2009; 51:505-15. [DOI: 10.1007/s00234-009-0522-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2009] [Accepted: 03/05/2009] [Indexed: 11/26/2022]
|
50
|
Pechlivanis I, Koenen D, Engelhardt M, Scholz M, Koenig M, Heuser L, Harders A, Schmieder K. Computed tomographic angiography in the evaluation of clip placement for intracranial aneurysm. Acta Neurochir (Wien) 2008; 150:669-76. [PMID: 18493701 DOI: 10.1007/s00701-008-1515-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2007] [Accepted: 11/13/2007] [Indexed: 11/26/2022]
Abstract
BACKGROUND Computed tomographic angiography (CTA) has been shown to reliably detect aneurysms pre-operatively. The aim of this study was to compare the ability of post-operative CTA to detect aneurysmal remnants in connection with clip placement compared with digital subtraction angiography (DSA). Furthermore, special attention was paid to identifying factors influencing the image quality of CTA. METHOD Between January 2005 and January 2006 a total of 76 patients with intracranial aneurysms were treated in our department. Thirty-two patients with a total of 33 clipped aneurysm were included in this study. All patients underwent CTA and DSA after surgery. Two investigators, each blinded to the classifications of the other, assessed image quality and clip placement. FINDINGS In three patients aneurysmal remnants could be detected with CTA and DSA. One 2-mm aneurysmal remnant was not clearly identified on CTA; two small (<2-mm) aneurysmal remnants were definitely not seen on CTA. A single titanium clip was used for aneurysmal clipping in 26 patients, two clips were needed in six patients and one aneurysm required three clips being used. Overall, use of one titanium clip tended to result in better image quality. In addition, clip-gantry angles between 30 degrees and 60 degrees tended to yield better image quality. CONCLUSION Post-operatively, CTA can be recommended as a reliable non-invasive diagnostic tool only with optimal image quality and with this criterion up to 66% of the aneurysms can be evaluated. Titanium artefacts, especially in the important zone (<2 mm) around the clip in which small aneurysmal remnants can occur, can render adequate evaluation impossible. CTA image quality depends on the number of titanium clips used, but clip-gantry-angle does not significantly influence the image quality.
Collapse
Affiliation(s)
- I Pechlivanis
- Department of Neurosurgery, Ruhr-University of Bochum, Knappschaftskrankenhaus Bochum-Langendreer, Bochum, Germany.
| | | | | | | | | | | | | | | |
Collapse
|