1
|
Widyasrini DA, Annisa M, Sunarintyas S, Samaranayake L, Siswomihardjo W. Magnesium Infusion on Dental Implants and Its Impact on Osseointegration and Biofilm Development: A Review. Eur J Dent 2025. [PMID: 40267963 DOI: 10.1055/s-0045-1806958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2025] Open
Abstract
Dental implants have gained global popularity as a treatment option for tooth loss. The success of dental implants depends on their optimal integration into the tissues of the alveolar bone and the periodontium. However, several factors can hinder the proper osseointegration of implants, with the growth of biofilm on the implant surface and subsequent peri-implant infections being significant concerns. To overcome this challenge, researchers have explored the incorporation of antimicrobial agents onto metallic implant surfaces to mitigate biofilm growth. Ideally these agents should promote osteogenesis while exhibiting antibacterial effects. Magnesium (Mg) has emerged as a promising dual-function implant coating due to its osteogenic and antibacterial properties. Despite several studies, the precise mechanisms behind osteoinductive and antimicrobial effect of Mg is unclear, as yet. This review aims to collate and discuss the utility of Mg as a dental implant coating, its impact on the osteogenic process, potential in mitigating microbial growth, and prospects for the future. A comprehensive literature search was conducted across several databases and the findings reveal the promise of Mg as a dual-function dental implant coating material, both as a standalone agent and in combination with other materials. The antibacterial effect of Mg is likely to be due to its (1) toxicity particularly at high concentrations, (2) the production or reactive oxygen species, and (3) pH modulation, while the osteoinductive effect is due to a complex series of cellular and biochemical pathways. Despite its potential both as a standalone and composite coating, challenges such as degradation rate, leaching, and long-term stability must be addressed. Further research is needed to understand the utility of Mg as an implant coating material, particularly in relation to its antibacterial activity, osseointegration, and longevity in the oral milieu.
Collapse
Affiliation(s)
- Dyah Anindya Widyasrini
- Department of Dental Biomaterial, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta, Indonesia
- Doctoral Study Program, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta, Indonesia
| | - Mutiara Annisa
- Department of Dental Biomaterial, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta, Indonesia
| | - Siti Sunarintyas
- Department of Dental Biomaterial, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta, Indonesia
| | - Lakshman Samaranayake
- Oral Biosciences, Faculty of Dentistry, University of Hong Kong, Sai Ying Pun, Hong Kong
- Dr DY Patil Dental College and Hospital, Dr DY Patil Vidyapeeth, Pimpri, Pune, India
| | - Widowati Siswomihardjo
- Department of Dental Biomaterial, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta, Indonesia
| |
Collapse
|
2
|
Mester A, Piciu D, Moldovan M, Sarosi C, Cuc S, Petean I, Moisescu-Pop C, Piciu A, Onisor F, Bran S. Zirconia Implants Indicated Better Stability After Exposure to Radioiodine-131 Therapy Used for Differentiated Thyroid Cancer. Cancers (Basel) 2025; 17:678. [PMID: 40002272 PMCID: PMC11852575 DOI: 10.3390/cancers17040678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2025] [Revised: 01/31/2025] [Accepted: 02/12/2025] [Indexed: 02/27/2025] Open
Abstract
Background: Advancements in therapeutic approaches and standard medical interventions have significantly improved the prognosis of patients with differentiated thyroid cancer. However, uncertainties remain regarding the optimal timing and protocols for dental implant placement in patients undergoing radioiodine-131 (I-131) therapy. Debates continue about the potential effects of radiation on osseointegration dynamics and implant viability. This in vitro study assessed the impact of radiodiodine-131 (I-131) used for differentiated thyroid cancer on the structure of zirconia and titanium implants. Methods: A total of 60 implants were utilized, with distribution into two cohorts: titanium implants (Ti, n = 30) and zirconia implants (Zr, n = 30). Subsequently, the Ti and Zr implants were immersed in I-131 solution and retrieved at specified time intervals: 0, 6, 12, 24, 48 h, and 8 days post irradiation. The analyses used to characterize the structure of the implants were radioactivity, scanning electron microscopy, atomic force microscopy, roughness, and Vickers hardness assessment. Results: The findings indicate that the zirconia implants exhibited minimal ultra-structural topographic changes after irradiation. Notable topographical changes and debris deposition on zirconia surfaces became evident after 24 h, with cumulative effects observed after 192 h. The titanium implants, on the other hand, showed surface alterations beginning at 12 h of exposure. Significant changes, including erosive patterns and substantial debris deposits, occurred after 48 and 192 h, leading to increased surface roughness by 24 h. Implants exposed for 12 and 24 h formed a statistically significant group, indicating the onset of surface alteration accumulation. The erosion debris confirmed the surface alterations induced by radioiodine-131 exposure. Conclusions: Overall, the Zr implants demonstrated greater stability compared to the Ti implants following radioiodine-131 exposure.
Collapse
Affiliation(s)
- Alexandru Mester
- Department of Oral Health, University of Medicine and Pharmacy “Iuliu Hatieganu”, 400012 Cluj-Napoca, Romania;
| | - Doina Piciu
- Doctoral School, University of Medicine and Pharmacy “Iuliu Hatieganu”, 400012 Cluj-Napoca, Romania;
| | - Marioara Moldovan
- Institute of Chemistry “Raluca Ripan”, University Babes-Bolyai, 400294 Cluj-Napoca, Romania; (M.M.); (C.S.); (S.C.)
| | - Codruta Sarosi
- Institute of Chemistry “Raluca Ripan”, University Babes-Bolyai, 400294 Cluj-Napoca, Romania; (M.M.); (C.S.); (S.C.)
| | - Stanca Cuc
- Institute of Chemistry “Raluca Ripan”, University Babes-Bolyai, 400294 Cluj-Napoca, Romania; (M.M.); (C.S.); (S.C.)
| | - Ioan Petean
- Faculty of Chemistry and Chemical Engineering, Babes-Bolyai University, 400084 Cluj-Napoca, Romania;
| | - Cristina Moisescu-Pop
- Department of Endocrine Tumors and Nuclear Medicine, Institute of Oncology “Ion Chiricuta”, 400015 Cluj-Napoca, Romania;
| | - Andra Piciu
- Department of Medical Oncology, University of Medicine and Pharmacy “Iuliu Hatieganu”, 400012 Cluj-Napoca, Romania
| | - Florin Onisor
- Department of Maxillofacial Surgery and Implantology, University of Medicine and Pharmacy “Iuliu Hatieganu”, 400012 Cluj-Napoca, Romania; (F.O.); (S.B.)
| | - Simion Bran
- Department of Maxillofacial Surgery and Implantology, University of Medicine and Pharmacy “Iuliu Hatieganu”, 400012 Cluj-Napoca, Romania; (F.O.); (S.B.)
| |
Collapse
|
3
|
Thangavelu L, Parthasarathy PR, Tharmar MAA. Ceramic Biomaterials in Dental Implantology—Time for Change of Status Quo: An Updated Review. WORLD JOURNAL OF DENTISTRY 2024; 15:733-742. [DOI: 10.5005/jp-journals-10015-2471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
4
|
Fatima Balderrama I, Schafer S, El Shatanofy M, Bergamo ETP, Mirsky NA, Nayak VV, Marcantonio Junior E, Alifarag AM, Coelho PG, Witek L. Biomimetic Tissue Engineering Strategies for Craniofacial Applications. Biomimetics (Basel) 2024; 9:636. [PMID: 39451842 PMCID: PMC11506466 DOI: 10.3390/biomimetics9100636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 09/21/2024] [Accepted: 10/11/2024] [Indexed: 10/26/2024] Open
Abstract
Biomimetics is the science of imitating nature's designs and processes to create innovative solutions for various fields, including dentistry and craniofacial reconstruction. In these areas, biomimetics involves drawing inspiration from living organisms/systems to develop new materials, techniques, and devices that closely resemble natural tissue structures and enhance functionality. This field has successfully demonstrated its potential to revolutionize craniofacial procedures, significantly improving patient outcomes. In dentistry, biomimetics offers exciting possibilities for the advancement of new dental materials, restorative techniques, and regenerative potential. By analyzing the structure/composition of natural teeth and the surrounding tissues, researchers have developed restorative materials that mimic the properties of teeth, as well as regenerative techniques that might assist in repairing enamel, dentin, pulp, cementum, periodontal ligament, and bone. In craniofacial reconstruction, biomimetics plays a vital role in developing innovative solutions for facial trauma, congenital defects, and various conditions affecting the maxillofacial region. By studying the intricate composition and mechanical properties of the skull and facial bones, clinicians and engineers have been able to replicate natural structures leveraging computer-aided design and manufacturing (CAD/CAM) and 3D printing. This has allowed for the creation of patient-specific scaffolds, implants, and prostheses that accurately fit a patient's anatomy. This review highlights the current evidence on the application of biomimetics in the fields of dentistry and craniofacial reconstruction.
Collapse
Affiliation(s)
- Isis Fatima Balderrama
- Department of Diagnosis and Surgery, School of Dentistry of Araraquara, Sao Paulo State University, Sao Paulo 14801-385, Brazil
- Biomaterials Division, NYU Dentistry, New York, NY 10010, USA
| | - Sogand Schafer
- Division of Plastic, Reconstructive and Oral Surgery, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA
| | - Muhammad El Shatanofy
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Edmara T. P. Bergamo
- Biomaterials Division, NYU Dentistry, New York, NY 10010, USA
- Department of Prosthodontics, NYU Dentistry, New York, NY 10010, USA
| | | | - Vasudev Vivekanand Nayak
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Elcio Marcantonio Junior
- Department of Diagnosis and Surgery, School of Dentistry of Araraquara, Sao Paulo State University, Sao Paulo 14801-385, Brazil
| | - Adham M. Alifarag
- Department of General Surgery, Temple University Hospital System, Philadelphia, PA 19140, USA
| | - Paulo G. Coelho
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA
- Division of Plastic Surgery, DeWitt Daughtry Family Department of Surgery, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Lukasz Witek
- Biomaterials Division, NYU Dentistry, New York, NY 10010, USA
- Department of Biomedical Engineering, NYU Tandon School of Engineering, Brooklyn, NY 11201, USA
- Hansjörg Wyss Department of Plastic Surgery, NYU Grossman School of Medicine, New York, NY 10016, USA
| |
Collapse
|
5
|
Andrade CS, Borges MHR, Silva JP, Malheiros S, Sacramento C, Ruiz KGS, da Cruz NC, Rangel EC, Fortulan C, Figueiredo L, Nagay BE, Souza JGS, Barão VAR. Micro-arc driven porous ZrO 2 coating for tailoring surface properties of titanium for dental implants application. Colloids Surf B Biointerfaces 2024; 245:114237. [PMID: 39293292 DOI: 10.1016/j.colsurfb.2024.114237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 09/09/2024] [Accepted: 09/10/2024] [Indexed: 09/20/2024]
Abstract
Titanium (Ti) is an ideal material for dental implants due to its excellent properties. However, corrosion and mechanical wear lead to Ti ions and particles release, triggering inflammatory responses and bone resorption. To overcome these challenges, surface modification techniques are used, including micro-arc oxidation (MAO). MAO creates adherent, porous coatings on Ti implants with diverse chemical compositions. In this context, zirconia element stands out in its wear and corrosion properties associated with low friction and chemical stability. Therefore, we investigated the impact of adding zirconium oxide (ZrO2) to Ti surfaces through MAO, aiming for improved electrochemical and mechanical properties. Additionally, the antimicrobial and modulatory potentials, cytocompatibility, and proteomic profile of surfaces were investigated. Ti discs were divided into four groups: machined - control (cpTi), treated by MAO with 0.04 M KOH - control (KOH), and two experimental groups incorporating ZrO2 at concentrations of 0.04 M and 0.08 M, composing the KOH@Zr4 and KOH@Zr8 groups. KOH@Zr8 showed higher surface porosity and roughness, even distribution of zirconia, formation of crystalline phases like ZrTiO4, and hydrophilicity. ZrO2 groups showed better mechanical performance including higher hardness values, lower wear area and mass loss, and higher friction coefficient under tribological conditions. The formation of a more compact oxide layer was observed, which favors the electrochemical stability of ZrO2 surfaces. Besides not inducing greater biofilm formation, ZrO2 surfaces reduced the load of pathogenic bacteria evidenced by the DNA-DNA checkerboard analysis. ZrO2 surfaces were cytocompatible with pre-osteoblastic cells. The saliva proteomic profile, evaluated by liquid chromatography coupled with tandem mass spectrometry, was slightly changed by zirconia, with more proteins adsorbed. KOH@Zr8 group notably absorbed proteins crucial for implant biological responses, like albumin and fibronectin. Incorporating ZrO2 improved the mechanical and electrochemical behavior of Ti surfaces, as well as modulated biofilm composition and provided suitable biological responses.
Collapse
Affiliation(s)
- Cátia Sufia Andrade
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Av Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Maria Helena R Borges
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Av Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - João Pedro Silva
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Av Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Samuel Malheiros
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Av Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Catharina Sacramento
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Av Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Karina G S Ruiz
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Av Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Nilson C da Cruz
- Laboratory of Technological Plasmas, Engineering College, Univ Estadual Paulista (UNESP), Av Três de Março, 511, Sorocaba, São Paulo 18087-180, Brazil
| | - Elidiane C Rangel
- Laboratory of Technological Plasmas, Engineering College, Univ Estadual Paulista (UNESP), Av Três de Março, 511, Sorocaba, São Paulo 18087-180, Brazil
| | - Carlos Fortulan
- Department of Mechanical Engineering, University of São Paulo (USP), Trabalhador São Carlense, 400, São Carlos, São Paulo 13566-590, Brazil
| | - Luciene Figueiredo
- Dental Research Division, Guarulhos University, Guarulhos, São Paulo 07023-070, Brazil
| | - Bruna E Nagay
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Av Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Joāo Gabriel S Souza
- Dental Research Division, Guarulhos University, Guarulhos, São Paulo 07023-070, Brazil
| | - Valentim A R Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Av Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil.
| |
Collapse
|
6
|
Mously HA, Naguib GH, Hashem ABH, Abougazia AO, Binmahfooz AM, Hamed MT. Influence of Connector Design on Displacement and Micromotion in Tooth-Implant Fixed Partial Dentures Using Different Lengths and Diameters: A Three-Dimensional Finite Element Study. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4416. [PMID: 39274806 PMCID: PMC11395790 DOI: 10.3390/ma17174416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Revised: 08/28/2024] [Accepted: 09/04/2024] [Indexed: 09/16/2024]
Abstract
The literature presents insufficient data evaluating the displacement and micromotion effects resulting from the combined use of tooth-implant connections in fixed partial dentures. Analyzing the biomechanical behavior of tooth-implant fixed partial denture (FPD) prothesis is vital for achieving an optimum design and successful clinical implementation. The objective of this study was to determine the relative significance of connector design on the displacement and micromotion of tooth-implant-supported fixed dental prostheses under occlusal vertical loading. A unilateral Kennedy class I mandibular model was created using a 3D reconstruction from CT scan data. Eight simulated designs of tooth-implant fixed partial dentures (FPDs) were split into two groups: Group A with rigid connectors and Group B with non-rigid connectors. The models were subjected to a uniform vertical load of 100 N. Displacement, strain, and stress were computed using finite element analysis. The materials were defined as isotropic, homogeneous, and exhibiting linear elastic properties. This study focused on assessing the maximum displacement in various components, including the bridge, mandible, dentin, cementum, periodontal ligament (PDL), and implant. Displacement values were predominantly higher in Group B (non-rigid) compared to Group A (rigid) in all measured components of the tooth-implant FPDs. Accordingly, a statistically significant difference was observed between the two groups at the FPD bridge (p value = 0.021 *), mandible (p value = 0.021 *), dentin (p value = 0.043 *), cementum (p value = 0.043 *), and PDL (p value = 0.043 *). Meanwhile, there was an insignificant increase in displacement values recorded in the distal implant (p value = 0.083). This study highlighted the importance of connector design in the overall stability and performance of the prosthesis. Notably, the 4.7 mm × 10 mm implant in Group B showed a displacement nearly 92 times higher than its rigid counterpart in Group A. Overall, the 5.7 mm × 10 mm combination of implant length and diameter showcased the best performance in both groups. The findings demonstrate that wider implants with a proportional length offer greater resistance to displacement forces. In addition, the use of rigid connection design provides superior biomechanical performance in tooth-implant fixed partial dentures and reduces the risk of micromotion with its associated complications such as ligament overstretching and implant overload, achieving predictable prognosis and enhancing the stability of the protheses.
Collapse
Affiliation(s)
- Hisham A Mously
- Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Ghada H Naguib
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- Department of Oral Biology, School of Dentistry, Cairo University, Cairo 12613, Egypt
| | | | | | - Abdulelah M Binmahfooz
- Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Mohamed T Hamed
- Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- Department of Fixed Prosthodontics, School of Dentistry, Cairo University, Cairo 12613, Egypt
| |
Collapse
|
7
|
Yotsuya M, Nakano M, Umehara K, Awazawa S, Nomura T, Kuribayashi N, Yoshinari M, Sekine H. A Case of Anterior Single Tooth Implant with Fractured Zirconia Abutment due to Trauma. THE BULLETIN OF TOKYO DENTAL COLLEGE 2024; 65:31-40. [PMID: 38749760 DOI: 10.2209/tdcpublication.2023-0028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/10/2024]
Abstract
In recent years, a wide variety of materials have been used in dental implant treatment. In selecting the superstructures and abutments to be used it is important to consider their potential effect on the stability and durability of the planned implant. Excessive force applied to an implant during maintenance commonly results in complications, such as fracture of the superstructure or abutment, and loosening or fracture of the screws. This report describes a case of implant treatment for a 23-year-old man with esthetic disturbance due to trauma to the maxillary anterior teeth. The left maxillary central incisor could not be conserved due to this trauma, which had been caused by a traffic accident. After extraction, the tooth was restored with an anterior bridge. The crown of the left maxillary lateral incisor was fractured at the crown margin and, at the patient's request, implant treatment was selected as the restorative treatment for the missing tooth. A thorough preoperative examination was performed using placement simulation software. One titanium screw-type implant was placed in the maxillary left central incisor under local anesthesia. An all-ceramic crown with a zirconia frame was placed as a screw-fixed direct superstructure. At one year postoperatively, however, the superstructure and abutment became detached due to trauma. The fractured zirconia abutment was removed and replaced with a remanufactured abutment and superstructure. The patient has reported no subsequent dental complaint over the last 11 years. In this case, a surface analysis of the fractured zirconia abutment was performed. The scanned images revealed a difference in the fracture surfaces between the tensile and compressive sides, and electron probe microanalysis demonstrated the presence of titanium on the fracture surface. It was inferred that the hard zirconia abutment had scraped the titanium from the internal surface of the implant.
Collapse
Affiliation(s)
- Mamoru Yotsuya
- Department of Fixed Prosthodontics, Tokyo Dental College
| | - Masahiro Nakano
- Department of Fixed Prosthodontics, Tokyo Dental College
- Aomori Implant Research Group
| | - Kazuhiro Umehara
- Department of Fixed Prosthodontics, Tokyo Dental College
- Aomori Implant Research Group
| | | | | | | | | | - Hideshi Sekine
- Department of Fixed Prosthodontics, Tokyo Dental College
| |
Collapse
|
8
|
López-Píriz R, Sevillano D, Fernández Domínguez M, Alou L, González N, Goyos-Ball L, Cabal B, Moya JS, Gómez-Lus ML, Torrecillas R. Peri-Implant Microbial Signature Shifts in Titanium, Zirconia and Ceria-Stabilized Zirconia Reinforced with Alumina Sites Subjected to Experimental Peri-Implantitis: A Preclinical Study in Dogs. Antibiotics (Basel) 2024; 13:690. [PMID: 39199990 PMCID: PMC11350813 DOI: 10.3390/antibiotics13080690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 07/17/2024] [Accepted: 07/22/2024] [Indexed: 09/01/2024] Open
Abstract
This study evaluates the dynamic shift in the microbiota at the peri-implant site of titanium (Ti) and zirconia (Zr) implants subjected to experimental peri-implantitis (PI) and, for the first time, of implants made of ceria-stabilized alumina-reinforced zirconia (Ce-TZP/Al), a revolutionary zirconia that is set to play a key role in modern implant dentistry. One- and two-piece (TP) implants, including Ce-TZP/AL TP/G3 glass, were placed bilaterally (six implants/side) in five beagle dogs to mimic a natural vs. ligature-induced PI following a split-mouth design. The experiment spanned 30 weeks from tooth extraction. Both PI models promoted plaque deposition at peri-implant sites. Comparatively, the PI induced by ligatures favored the deposition of anaerobes (p = 0.047 vs. natural). Regardless of the model, the plaque deposition pattern was entirely dependent on the implanted material. Ligated Ti and Zr implant sites accumulated up to 2.14 log CFU/mL unit anaerobic load (p ≤ 0.033 vs. non-ligated implant sites), predominantly comprising obligate anaerobes. Naturally occurring PI induced the deposition of co-occurring networks of obligate anaerobes and less oxygen-dependent bacteria. PI induction favored the enrichment of Ti and Zr sites with bacterial taxa belonging to the orange and red complexes (up to 28% increase naturally and up to 71% in the ligated hemiarch). Anaerobic deposition was significantly lower in ligated Ce-TZP/Al implant sites (p ≤ 0.014 vs. TI and Zr) and independent of the induction model (0.63-1 log units of increase). Facultative bacteria prevailed at Ce-TZP/AL sites. The abundance was lower in the Ce-TZP/AL TP implant. Unlike Ti and Zr sites, taxa from the orange and red complexes were negligible. Biofilms configured at the Ti and Zr sites after ligation-induced PI resemble those found in severe IP. We hypothesize that, although surface properties (surface energy and surface roughness) and physicochemical properties of the substrate play an important role in bacterial adhesion and subsequent plaque formation, Ce-TZP/Al modulates several biological activities that preserve the integrity of the gingival seal by limiting PI progression. In conclusion, biofilm progression differs in peri-implant sites according to the specific properties of the material. Ce-TZP/A, unlike titanium or zirconia, prevents dysbiosis in sites subjected to experimental PI and preserves the microbial signature of emergent obligate anaerobes related to PI development.
Collapse
Affiliation(s)
- Roberto López-Píriz
- Advanced Oral Surgery Institute (ICOA), 28012 Madrid, Spain;
- Nanomaterials and Nanotechnology Research Center (CINN-CSIC), Universidad de Oviedo (UO), Principado de Asturias, 33940 El Entrego, Spain; (B.C.); (J.S.M.)
| | - David Sevillano
- Microbiology Area-Medicine Department, School of Medicine, Universidad Complutense de Madrid, 28040 Madrid, Spain; (L.A.); (N.G.); (M.L.G.-L.)
| | | | - Luis Alou
- Microbiology Area-Medicine Department, School of Medicine, Universidad Complutense de Madrid, 28040 Madrid, Spain; (L.A.); (N.G.); (M.L.G.-L.)
| | - Natalia González
- Microbiology Area-Medicine Department, School of Medicine, Universidad Complutense de Madrid, 28040 Madrid, Spain; (L.A.); (N.G.); (M.L.G.-L.)
| | - Lidia Goyos-Ball
- Nanoker Research S.L., Polígono Industrial de Olloniego, 33660 Oviedo, Spain; (L.G.-B.); (R.T.)
| | - Belén Cabal
- Nanomaterials and Nanotechnology Research Center (CINN-CSIC), Universidad de Oviedo (UO), Principado de Asturias, 33940 El Entrego, Spain; (B.C.); (J.S.M.)
| | - José Serafín Moya
- Nanomaterials and Nanotechnology Research Center (CINN-CSIC), Universidad de Oviedo (UO), Principado de Asturias, 33940 El Entrego, Spain; (B.C.); (J.S.M.)
| | - María Luisa Gómez-Lus
- Microbiology Area-Medicine Department, School of Medicine, Universidad Complutense de Madrid, 28040 Madrid, Spain; (L.A.); (N.G.); (M.L.G.-L.)
| | - Ramón Torrecillas
- Nanoker Research S.L., Polígono Industrial de Olloniego, 33660 Oviedo, Spain; (L.G.-B.); (R.T.)
| |
Collapse
|
9
|
Hossain MI, Shams AB, Das Gupta S, Blanchard GJ, Mobasheri A, Hoque Apu E. The Potential Role of Ionic Liquid as a Multifunctional Dental Biomaterial. Biomedicines 2023; 11:3093. [PMID: 38002093 PMCID: PMC10669305 DOI: 10.3390/biomedicines11113093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/27/2023] [Accepted: 11/14/2023] [Indexed: 11/26/2023] Open
Abstract
In craniofacial research and routine dental clinical procedures, multifunctional materials with antimicrobial properties are in constant demand. Ionic liquids (ILs) are one such multifunctional intelligent material. Over the last three decades, ILs have been explored for different biomedical applications due to their unique physical and chemical properties, high task specificity, and sustainability. Their stable physical and chemical characteristics and extremely low vapor pressure make them suitable for various applications. Their unique properties, such as density, viscosity, and hydrophilicity/hydrophobicity, may provide higher performance as a potential dental material. ILs have functionalities for optimizing dental implants, infiltrate materials, oral hygiene maintenance products, and restorative materials. They also serve as sensors for dental chairside usage to detect oral cancer, periodontal lesions, breath-based sobriety, and dental hard tissue defects. With further optimization, ILs might also make vital contributions to craniofacial regeneration, oral hygiene maintenance, oral disease prevention, and antimicrobial materials. This review explores the different advantages and properties of ILs as possible dental material.
Collapse
Affiliation(s)
- Md Iqbal Hossain
- Department of Chemistry, Michigan State University, East Lansing, MI 48824, USA; (M.I.H.); (G.J.B.)
| | - Abdullah Bin Shams
- The Edward S. Rogers Sr. Department of Electrical Computer Engineering, University of Toronto, Toronto, ON M5S 3G4, Canada;
| | - Shuvashis Das Gupta
- Research Unit of Health Science and Technology, Faculty of Medicine, University of Oulu, 90220 Oulu, Finland; (S.D.G.); (A.M.)
| | - Gary J. Blanchard
- Department of Chemistry, Michigan State University, East Lansing, MI 48824, USA; (M.I.H.); (G.J.B.)
| | - Ali Mobasheri
- Research Unit of Health Science and Technology, Faculty of Medicine, University of Oulu, 90220 Oulu, Finland; (S.D.G.); (A.M.)
- Division of Public Health, Epidemiology and Health Economics, WHO Collaborating Center for Public Health Aspects of Musculo-Skeletal Health and Ageing, University of Liège, 4000 Liège, Belgium
- State Research Institute Centre for Innovative Medicine, 08410 Vilnius, Lithuania
- Department of Joint Surgery, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080, China
| | - Ehsanul Hoque Apu
- Research Unit of Health Science and Technology, Faculty of Medicine, University of Oulu, 90220 Oulu, Finland; (S.D.G.); (A.M.)
- Department of Biomedical Sciences, College of Dental Medicine, Lincoln Memorial University, Knoxville, TN 37923, USA
- Institute for Quantitative Health Science and Engineering, Department of Biomedical Engineering, Michigan State University, East Lansing, MI 48824, USA
- Division of Hematology and Oncology, Department of Internal Medicine, Michigan Medicine, University of Michigan, Ann Arbor, MI 48109, USA
- Centre for International Public Health and Environmental Research, Bangladesh (CIPHER,B), Dhaka 1207, Bangladesh
| |
Collapse
|
10
|
Murphy B, Baez J, Morris MA. Characterising Hydroxyapatite Deposited from Solution onto Novel Substrates: Growth Mechanism and Physical Properties. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2483. [PMID: 37686991 PMCID: PMC10489777 DOI: 10.3390/nano13172483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 08/29/2023] [Accepted: 09/01/2023] [Indexed: 09/10/2023]
Abstract
Whilst titanium, stainless steel, and cobalt-chrome alloys are the most common materials for use in orthopaedic implant devices, there are significant advantages in moving to alternative non-metallic substrates. Substrates such as polymers may have advantageous mechanical biological properties whilst other substrates may bring unique capability. A key challenge in the use of non-metal products is producing substrates which can be modified to allow the formation of well-adhered hydroxyapatite films which promote osteointegration and have other beneficial properties. In this work, we aim to develop methodology for the growth of hydroxyapatite films on surfaces other than bulk metallic parts using a wet chemical coating process, and we provide a detailed characterisation of the coatings. In this study, hydroxyapatite is grown from saturated solutions onto thin titanium films and silicon substrates and compared to results from titanium alloy substrates. The coating process efficacy is shown to be dependent on substrate roughness, hydrophilicity, and activation. The mechanism of the hydroxyapatite growth is investigated in terms of initial attachment and morphological development using SEM and XPS analysis. XPS analysis reveals the exact chemical state of the hydroxyapatite compositional elements of Ca, P, and O. The characterisation of grown hydroxyapatite layers by XRD reveals that the hydroxyapatite forms from amorphous phases, displaying preferential crystal growth along the [002] direction, with TEM imagery confirming polycrystalline pockets amid an amorphous matrix. SEM-EDX and FTIR confirmed the presence of hydroxyapatite phases through elemental atomic weight percentages and bond assignment. All data are collated and reviewed for the different substrates. The results demonstrate that once hydroxyapatite seeds, it crystallises in the same manner as bulk titanium whether that be on a titanium or silicon substrate. These data suggest that a range of substrates may be coated using this facile hydroxyapatite deposition technique, just broadening the choice of substrate for a particular function.
Collapse
Affiliation(s)
- Bríd Murphy
- Advanced Materials & Bioengineering Research Centre (AMBER), Trinity College Dublin, Dublin 2, D02 CP49 Dublin, Ireland;
- School of Chemistry, Trinity College Dublin, Dublin 2, D02 PN40 Dublin, Ireland
| | - Jhonattan Baez
- Advanced Materials & Bioengineering Research Centre (AMBER), Trinity College Dublin, Dublin 2, D02 CP49 Dublin, Ireland;
- School of Chemistry, Trinity College Dublin, Dublin 2, D02 PN40 Dublin, Ireland
| | - Mick A. Morris
- Advanced Materials & Bioengineering Research Centre (AMBER), Trinity College Dublin, Dublin 2, D02 CP49 Dublin, Ireland;
- School of Chemistry, Trinity College Dublin, Dublin 2, D02 PN40 Dublin, Ireland
| |
Collapse
|
11
|
Spitznagel FA, Hoppe JS, Bonfante EA, Campos TMB, Langner R, Gierthmuehlen PC. Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia Implants. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8465. [PMID: 36499960 PMCID: PMC9740162 DOI: 10.3390/ma15238465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/19/2022] [Accepted: 11/23/2022] [Indexed: 06/17/2023]
Abstract
No evidence-based prosthetic treatment concept for 3-unit fixed-dental-prostheses (FDPs) on ceramic implants is currently available. Therefore, the aim of this in vitro study was to investigate the failure load and fatigue behavior of monolithic and bi-layer zirconia FDPs supported by one-piece ceramic implants. Eighty 3-unit FDPs supported by 160 zirconia-implants (ceramic.implant; vitaclinical) were divided into 4 groups (n = 20 each): Group Z-HT: 3Y-TZP monolithic-zirconia (Vita-YZ-HT); Group Z-ST: 4Y-TZP monolithic-zirconia (Vita-YZ-ST); Group FL: 3Y-TZP zirconia (Vita-YZ-HT) with facial-veneer (Vita-VM9); Group RL (Rapid-layer): PICN “table-top” (Vita-Enamic), 3Y-TZP-framework (Vita-YZ-HT). Half of the test samples (n = 10/group) were fatigued in a mouth-motion chewing-simulator (F = 98 N, 1.2 million-cycles) with simultaneous thermocycling (5−55 °C). All specimens (fatigued and non-fatigued) were afterwards exposed to single-load-to-failure-testing (Z010, Zwick). Statistical analysis was performed using ANOVA, Tukey’s post-hoc tests and two-sample t-tests (p < 0.05, Bonferroni-corrected where appropriate). All specimens withstood fatigue application. While the effect of fatigue was not significant in any group (p = 0.714), the choice of material had a significant effect (p < 0.001). Material FL recorded the highest failure loads, followed by Z-ST, Z-HT and RL, both with and without fatigue application. Taken together, all tested FDP material combinations survived chewing forces that exceeded physiological levels. Bi-Layer FL and monolithic Z-ST showed the highest resilience and might serve as reliable prosthetic reconstruction concepts for 3-unit FDPs on ceramic implants.
Collapse
Affiliation(s)
- Frank A. Spitznagel
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine University, Moorenstraße 5, 40225 Düsseldorf, Germany
| | - Johanna S. Hoppe
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine University, Moorenstraße 5, 40225 Düsseldorf, Germany
| | - Estevam A. Bonfante
- Department of Prosthodontics and Periodontology; Bauru School of Dentistry, University of Sao Paulo, Bauru 17012-230, SP, Brazil
| | - Tiago M. B. Campos
- Department of Prosthodontics and Periodontology; Bauru School of Dentistry, University of Sao Paulo, Bauru 17012-230, SP, Brazil
| | - Robert Langner
- Institute of Systems Neuroscience, Medical Faculty, Heinrich-Heine-University, 40225 Düsseldorf, Germany
- Institute of Neuroscience and Medicine, Brain and Behavior (INM-7), Research Center Jülich, 52425 Jülich, Germany
| | - Petra C. Gierthmuehlen
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine University, Moorenstraße 5, 40225 Düsseldorf, Germany
| |
Collapse
|
12
|
Shokri A, Vafaee F, Haghighat L, Shahabi S, Farhadian M, Jamalpour MR. Comparison of the amount of artifacts induced by zirconium and titanium implants in cone-beam computed tomography images. BMC Med Imaging 2022; 22:156. [PMID: 36057551 PMCID: PMC9440550 DOI: 10.1186/s12880-022-00884-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 08/29/2022] [Indexed: 11/18/2022] Open
Abstract
Background This study aimed to compare the amount of artifacts induced by the titanium and zirconium implants on cone-beam computed tomography (CBCT) and assess the effect of different exposure settings on the image quality for both materials.
Methods In this experimental study, 30 zirconium and 30 titanium implants were placed in bovine rib bone blocks. CBCT images were taken in two different fields of view (FOV: 4 × 6 cm2 and 6 × 8 cm2) and at two resolutions (133 µ and 200 µ voxel size). Subsequently, two observers assessed the images and detected the amount of artifacts around the implants through gray values. Data were analyzed by paired t test and independent t test using SPSS 21 and the 0.05 significance level. Results The results showed that titanium implants caused lower amounts of artifacts than zirconium implants, which was statistically significant (P < 0.001). The larger FOV (6 × 8 cm2) resulted in a lower amount of artifacts in both groups, although the results were only statistically significant in the zirconium group (P < 0.001). The amount of artifacts was increased when using the 133 µ voxel size in both groups, which was only significant in the zirconium group (P < 0.001). Conclusion Our results suggest that zirconium implants induce higher amounts of artifacts than titanium ones. We also concluded that the artifacts could be minimized using the larger FOV and voxel size.
Collapse
Affiliation(s)
- Abbas Shokri
- Department of Oral and Maxillofacial Radiology, Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Fariborz Vafaee
- Department of Prosthodontics, Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | | | - Shiva Shahabi
- Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Maryam Farhadian
- Department of Biostatistics, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Mohammad Reza Jamalpour
- Department of Oral and Maxillofacial Surgery, Dental Implants Research Center, Hamadan University of Medical Sciences, Shaheed Fahmideh Avenue, Hamadan, 6517838636, Iran.
| |
Collapse
|
13
|
Ardhani R, Diana R, Pidhatika B. How Porphyromonas gingivalis Navigate the Map: The Effect of Surface Topography on the Adhesion of Porphyromonas gingivalis on Biomaterials. MATERIALS (BASEL, SWITZERLAND) 2022; 15:4988. [PMID: 35888454 PMCID: PMC9318924 DOI: 10.3390/ma15144988] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 06/25/2022] [Accepted: 07/07/2022] [Indexed: 11/16/2022]
Abstract
The main purpose of this study is to develop an understanding of how Porphyromonas gingivalis responds to subperiosteal implant surface topography. A literature review was drawn from various electronic databases from 2000 to 2021. The two main keywords used were "Porphyromonas gingivalis" and "Surface Topography". We excluded all reviews and or meta-analysis articles, articles not published in English, and articles with no surface characterization process or average surface roughness (Ra) value. A total of 26 selected publications were then included in this study. All research included showed the effect of topography on Porphyromonas gingivalis to various degrees. It was found that topography features such as size and shape affected Porphyromonas gingivalis adhesion to subperiosteal implant materials. In general, a smaller Ra value reduces Porphyromonas gingivalis regardless of the type of materials, with a threshold of 0.3 µm for titanium.
Collapse
Affiliation(s)
- Retno Ardhani
- Department of Dental Biomedical Science, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta 55281, Indonesia;
| | - Rasda Diana
- Audy Dental Clinic, Jakarta 17214, Indonesia
| | - Bidhari Pidhatika
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia—PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia;
| |
Collapse
|
14
|
Cruz MB, Silva N, Marques JF, Mata A, Silva FS, Caramês J. Biomimetic Implant Surfaces and Their Role in Biological Integration-A Concise Review. Biomimetics (Basel) 2022; 7:74. [PMID: 35735590 PMCID: PMC9220941 DOI: 10.3390/biomimetics7020074] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/25/2022] [Accepted: 05/27/2022] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND The increased use of dental implants in oral rehabilitation has been followed by the development of new biomaterials as well as improvements in the performance of biomaterials already in use. This triggers the need for appropriate analytical approaches to assess the biological and, ultimately, clinical benefits of these approaches. AIMS To address the role of physical, chemical, mechanical, and biological characteristics in order to determine the critical parameters to improve biological responses and the long-term effectiveness of dental implant surfaces. DATA SOURCES AND METHODS Web of Science, MEDLINE and Lilacs databases were searched for the last 30 years in English, Spanish and Portuguese idioms. RESULTS Chemical composition, wettability, roughness, and topography of dental implant surfaces have all been linked to biological regulation in cell interactions, osseointegration, bone tissue and peri-implant mucosa preservation. CONCLUSION Techniques involving subtractive and additive methods, especially those involving laser treatment or embedding of bioactive nanoparticles, have demonstrated promising results. However, the literature is heterogeneous regarding study design and methodology, which limits comparisons between studies and the definition of the critical determinants of optimal cell response.
Collapse
Affiliation(s)
- Mariana Brito Cruz
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal; (J.F.M.); (A.M.)
| | - Neusa Silva
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), LIBPhys-FTC UID/FIS/04559/2013, Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal;
| | - Joana Faria Marques
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal; (J.F.M.); (A.M.)
| | - António Mata
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal; (J.F.M.); (A.M.)
- Cochrane Portugal, Instituto de Saúde Baseada na Evidência (ISBE), Faculdade de Medicina Dentária, Universidade de Lisboa, Avenida Professor Egas Moniz, 1649-028 Lisboa, Portugal
| | - Felipe Samuel Silva
- Center for Microelectromechanical Systems (CMEMS), Department of Mechanical Engineering, University of Minho, 4800-058 Guimarães, Portugal;
| | - João Caramês
- Bone Physiology Research Group, Faculdade de Medicina Dentária, Universidade de Lisboa, Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal;
| |
Collapse
|
15
|
Choi SM, Choi H, Lee DH, Hong MH. Comparative finite element analysis of mandibular posterior single zirconia and titanium implants: a 3-dimensional finite element analysis. J Adv Prosthodont 2022; 13:396-407. [PMID: 35003555 PMCID: PMC8712109 DOI: 10.4047/jap.2021.13.6.396] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 11/23/2021] [Accepted: 12/06/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Zirconia has exceptional biocompatibility and good mechanical properties in clinical situations. However, finite element analysis (FEA) studies on the biomechanical stability of two-piece zirconia implant systems are limited. Therefore, the aim of this study was to compare the biomechanical properties of the two-piece zirconia and titanium implants using FEA. MATERIALS AND METHODS Two groups of finite element (FE) models, the zirconia (Zircon) and titanium (Titan) models, were generated for the exam. Oblique (175 N) and vertical (175 N) loads were applied to the FE model generated for FEA simulation, and the stress levels and distributions were investigated. RESULTS In oblique loading, von Mises stress values were the highest in the abutment of the Zircon model. The von Mises stress values of the Titan model for the abutment screw and implant fixture were slightly higher than those of the Zircon model. Minimum principal stress in the cortical bone was higher in the Titan model than Zircon model under oblique and vertical loading. Under both vertical and oblique loads, stress concentrations in the implant components and bone occurred in the same area. Because the material itself has high stiffness and elastic modulus, the Zircon model exhibited a higher von Mises stress value in the abutments than the Titan model, but at a level lower than the fracture strength of the material. CONCLUSION Owing to the good esthetics and stress controllability of the Zircon model, it can be considered for clinical use.
Collapse
Affiliation(s)
- Sung-Min Choi
- Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan, Busan, Republic of Korea
| | - Hyunsuk Choi
- Department of Dentistry and Prosthodontics, Daegu Catholic University School of Medicine, Daegu, Republic of Korea
| | - Du-Hyeong Lee
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Min-Ho Hong
- Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan, Busan, Republic of Korea
| |
Collapse
|