1
|
Junping Z, Zheng W, ZhengFang T, Yue LIJ, PengHang A, Mingli Z, Hongzhi A. Novel electrochemical platform based on C 3N 4-graphene composite for the detection of neuron-specific enolase as a biomarker for lung cancer. Sci Rep 2024; 14:6350. [PMID: 38491108 PMCID: PMC10943129 DOI: 10.1038/s41598-024-56784-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 03/11/2024] [Indexed: 03/18/2024] Open
Abstract
Lung cancer remains the leading cause of cancer mortality worldwide. Small cell lung cancer (SCLC) accounts for 10-15% of cases and has an overall 5-years survival rate of only 15%. Neuron-specific enolase (NSE) has been identified as a useful biomarker for early SCLC diagnosis and therapeutic monitoring. This work reports an electrochemical immunosensing platform based on a graphene-graphitic carbon nitride (g-C3N4) nanocomposite for ultrasensitive NSE detection. The g-C3N4 nanosheets and graphene nanosheets were synthesized via liquid exfoliation and integrated through self-assembly to form the nanocomposite. This nanocomposite was used to modify screen-printed carbon electrodes followed by covalent immobilization of anti-NSE antibodies. The unique properties of the graphene-g-C3N4 composite facilitated efficient antibody loading while also enhancing electron transfer efficiency and electrochemical response. Systematic optimization of experimental parameters was performed. The immunosensor exhibited a wide linear detection range of 10 pg/mL to 100 ng/mL and low limit of detection of 3 pg/mL for NSE along with excellent selectivity against interferences. Real serum matrix analysis validated the applicability of the developed platform for sensitive and accurate NSE quantifica-tion at clinically relevant levels. This novel graphene-g-C3N4 nanocomposite based electro-chemical immunoassay demonstrates great promise for early diagnosis of SCLC.
Collapse
Affiliation(s)
- Zhang Junping
- Cancer Research Institute, Henan Integrative Medicine Hospital 45000, Zhengzhou, China
| | - Wei Zheng
- Cancer Research Institute, Henan Integrative Medicine Hospital 45000, Zhengzhou, China.
| | - Tang ZhengFang
- The First School of Clinical Medicine, Henan University of Chinese Medicine, Zhengzhou, 450004, China
| | - L I Ji Yue
- The First School of Clinical Medicine, Henan University of Chinese Medicine, Zhengzhou, 450004, China
| | - An PengHang
- The First School of Clinical Medicine, Henan University of Chinese Medicine, Zhengzhou, 450004, China
| | - Zhang Mingli
- Cancer Research Institute, Henan Integrative Medicine Hospital 45000, Zhengzhou, China.
| | - An Hongzhi
- Cancer Research Institute, Henan Integrative Medicine Hospital 45000, Zhengzhou, China.
| |
Collapse
|
2
|
Kumar AS, Venkatesalu S, Dilliyappan S, Pasupulla AP, Prathap L, Palaniyandi T, Baskar G, Ravi M, Sugumaran A. Microfluidics as diagnostic tools. Clin Chim Acta 2024; 556:117841. [PMID: 38395126 DOI: 10.1016/j.cca.2024.117841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 02/17/2024] [Accepted: 02/18/2024] [Indexed: 02/25/2024]
Abstract
The challenges in the management of human diseases are largely determined by the precision, speed and ease of diagnostic procedures available. Developments in biomedical engineering technologies have greatly helped in transforming human health care, especially for disease diagnosis which in turn lead to better patient outcomes. One such development is in the form of microfluidic chip technology which has transformed various aspects of human health care. We present in this review, a comprehensive account on the utility of microfluidic chip technologies for the diagnosis of autoimmune disorders, cardiovascular diseases (CVDs), infectious diseases, and neurodegenerative conditions. We have included the diseases posing global threat such as rheumatoid arthritis, diabetes, pernicious anemia, tuberculosis, COVID-19, influenza, alzheimer's, multiple sclerosis, and epilepsy. Apart from discussing the ways of microfluidic chip in diagnosis, we included a section presenting electrochemical, electrical, optical, and acoustic detection technologies for the precise diagnosis of CVDs. Microfluidics platforms have thus revolutionized novel capabilities in addressing the requirements of point-of-care diagnostics enabling miniaturization by integrating multiple laboratory functions into a single chip resulting in "one flow - one solution" systems. Hence, the precision and early diagnoses of diseases are now possible due to the advancements of microfluidics-based technology.
Collapse
Affiliation(s)
- Avanthika Satish Kumar
- Department of Biotechnology, Dr. M.G.R. Educational and Research Institute, Chennai, India
| | - Sneha Venkatesalu
- Department of Biotechnology, Dr. M.G.R. Educational and Research Institute, Chennai, India
| | | | - Ajay Prakash Pasupulla
- Oral and Maxillofacial Pathologist, School of Medicine, College of Health Sciences, Nigist Eleni Comprehensive Specialized Hospital, Wachemo University, Hossana, Ethiopia, East Africa
| | - Lavanya Prathap
- Department of Anatomy, Biomedical Research Unit and Laboratory Animal Centre, Saveetha Dental College and Hospital, SIMATS, Saveetha University, Chennai, India
| | - Thirunavukkarasu Palaniyandi
- Department of Biotechnology, Dr. M.G.R. Educational and Research Institute, Chennai, India; Department of Anatomy, Biomedical Research Unit and Laboratory Animal Centre, Saveetha Dental College and Hospital, SIMATS, Saveetha University, Chennai, India.
| | - Gomathy Baskar
- Department of Biotechnology, Dr. M.G.R. Educational and Research Institute, Chennai, India
| | - Maddaly Ravi
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research, Chennai, India
| | - Abimanyu Sugumaran
- Department of Pharmaceutical Sciences, Assam University, Silchar, Assam, India
| |
Collapse
|
3
|
Ono T, Okuda S, Ushiba S, Kanai Y, Matsumoto K. Challenges for Field-Effect-Transistor-Based Graphene Biosensors. MATERIALS (BASEL, SWITZERLAND) 2024; 17:333. [PMID: 38255502 PMCID: PMC10817696 DOI: 10.3390/ma17020333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 12/28/2023] [Accepted: 01/06/2024] [Indexed: 01/24/2024]
Abstract
Owing to its outstanding physical properties, graphene has attracted attention as a promising biosensor material. Field-effect-transistor (FET)-based biosensors are particularly promising because of their high sensitivity that is achieved through the high carrier mobility of graphene. However, graphene-FET biosensors have not yet reached widespread practical applications owing to several problems. In this review, the authors focus on graphene-FET biosensors and discuss their advantages, the challenges to their development, and the solutions to the challenges. The problem of Debye screening, in which the surface charges of the detection target are shielded and undetectable, can be solved by using small-molecule receptors and their deformations and by using enzyme reaction products. To address the complexity of sample components and the detection mechanisms of graphene-FET biosensors, the authors outline measures against nonspecific adsorption and the remaining problems related to the detection mechanism itself. The authors also introduce a solution with which the molecular species that can reach the sensor surfaces are limited. Finally, the authors present multifaceted approaches to the sensor surfaces that provide much information to corroborate the results of electrical measurements. The measures and solutions introduced bring us closer to the practical realization of stable biosensors utilizing the superior characteristics of graphene.
Collapse
Affiliation(s)
- Takao Ono
- SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan
| | - Satoshi Okuda
- High Frequency & Optical Device Works, Mitsubishi Electric Corporation, 4-1 Mizuhara, Itami, Sendai 664-8641, Japan
| | - Shota Ushiba
- Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Kyoto 617-8555, Japan
| | - Yasushi Kanai
- International Center for Synchrotron Radiation Innovation Smart, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
| | | |
Collapse
|
4
|
Lokar N, Pečar B, Možek M, Vrtačnik D. Microfluidic Electrochemical Glucose Biosensor with In Situ Enzyme Immobilization. BIOSENSORS 2023; 13:364. [PMID: 36979576 PMCID: PMC10046266 DOI: 10.3390/bios13030364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/03/2023] [Accepted: 03/08/2023] [Indexed: 06/18/2023]
Abstract
The development and characterization of a microfluidic electrochemical glucose biosensor are presented herein. The transducer part is based on thin-film metal electrodes on a glass substrate. The biological recognition element of the biosensor is the pyrroloquinoline quinone-glucose dehydrogenase (PQQ-GdhB) enzyme, selectively in situ immobilized via microcontact printing of a mixed self-assembling monolayer (SAM) on a gold working electrode, while the microfluidic part of the device comprises microchannel and microfluidic connections formed in a polydimethylsiloxane (PDMS) elastomer. The electrode properties throughout all steps of biosensor construction and the biosensor response to glucose concentration and analyte flow rate were characterized by cyclic voltammetry and chronoamperometry. A measurement range of up to 10 mM in glucose concentration with a linear range up to 200 μM was determined. A detection limit of 30 µM in glucose concentration was obtained. Respective biosensor sensitivities of 0.79 nA/µM/mm2 and 0.61 nA/µM/mm2 were estimated with and without a flow at 20 µL/min. The developed approach of in situ enzyme immobilization can find a wide number of applications in the development of microfluidic biosensors, offering a path towards continuous and time-independent detection.
Collapse
|
5
|
Chougale A, Vedante S, Kulkarni G, Patnawar S. Recent Progress on Biosensors for the Early Detection of Neurological Disorders. ChemistrySelect 2022. [DOI: 10.1002/slct.202203155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
Affiliation(s)
- Amit Chougale
- Department of Chemical Engineering University of Adelaide SA Australia 5000
| | - Shruti Vedante
- Department of Chemical Engineering University of Adelaide SA Australia 5000
| | - Guruprasad Kulkarni
- Department of Biotechnology Kolhapur Institute of Technology's College of Engineering Kolhapur Maharashtra India 416234
| | - Sneha Patnawar
- Department of Biotechnology Kolhapur Institute of Technology's College of Engineering Kolhapur Maharashtra India. 416234
| |
Collapse
|
6
|
Chircov C, Bîrcă AC, Vasile BS, Oprea OC, Huang KS, Grumezescu AM. Microfluidic Synthesis of -NH 2- and -COOH-Functionalized Magnetite Nanoparticles. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:3160. [PMID: 36144948 PMCID: PMC9503789 DOI: 10.3390/nano12183160] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 09/02/2022] [Accepted: 09/08/2022] [Indexed: 06/16/2023]
Abstract
Microfluidics has emerged as a promising alternative for the synthesis of nanoparticles, which ensures precise control over the synthesis parameters, high uniformity, reproducibility, and ease of integration. Therefore, the present study investigated a one-step synthesis and functionalization of magnetite nanoparticles (MNPs) using sulfanilic acid (SA) and 4-sulfobenzoic acid (SBA). The flows of both the precursor and precipitating/functionalization solutions were varied in order to ensure the optimal parameters. The obtained nanoparticles were characterized through dynamic light scattering (DLS) and zeta potential, X-ray diffraction (XRD), selected area electron diffraction (SAED), transmission electron microscopy (TEM) and high-resolution TEM (HR-TEM), Fourier transform infrared spectroscopy (FT-IR), thermogravimetry and differential scanning calorimetry (TG-DSC), and vibrating sample magnetometry (VSM). The results demonstrated the successful synthesis of magnetite as the unique mineralogical phase, as well as the functionalization of the nanoparticles. Furthermore, the possibility to control the crystallinity, size, shape, and functionalization degree by varying the synthesis parameters was further confirmed. In this manner, this study validated the potential of the microfluidic platform to develop functionalized MNPs, which are suitable for biomedical and pharmaceutical applications.
Collapse
Affiliation(s)
- Cristina Chircov
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania
- National Research Center for Micro and Nanomaterials, University Politehnica of Bucharest, 060042 Bucharest, Romania
| | - Alexandra Cătălina Bîrcă
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania
- National Research Center for Micro and Nanomaterials, University Politehnica of Bucharest, 060042 Bucharest, Romania
| | - Bogdan Stefan Vasile
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania
- National Research Center for Micro and Nanomaterials, University Politehnica of Bucharest, 060042 Bucharest, Romania
- National Research Center for Food Safety, University Politehnica of Bucharest, 060042 Bucharest, Romania
| | - Ovidiu-Cristian Oprea
- National Research Center for Micro and Nanomaterials, University Politehnica of Bucharest, 060042 Bucharest, Romania
- Department of Inorganic Chemistry, Physical Chemistry and Electrochemistry, University Politehnica of Bucharest, 1-7 Polizu Street, 011061 Bucharest, Romania
| | - Keng-Shiang Huang
- The School of Chinese Medicine for Post-Baccalaureate, I-Shou University, Kaohsiung 840301, Taiwan
| | - Alexandru Mihai Grumezescu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania
- National Research Center for Micro and Nanomaterials, University Politehnica of Bucharest, 060042 Bucharest, Romania
- Research Institute of the University of Bucharest—ICUB, University of Bucharest, 050657 Bucharest, Romania
- Academy of Romanian Scientists, 54 Splaiul Independentei, 050045 Bucharest, Romania
| |
Collapse
|
7
|
Liu M, Xiang Y, Yang Y, Long X, Xiao Z, Nan Y, Jiang Y, Qiu Y, Huang Q, Ai K. State-of-the-art advancements in Liver-on-a-chip (LOC): Integrated biosensors for LOC. Biosens Bioelectron 2022; 218:114758. [DOI: 10.1016/j.bios.2022.114758] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 09/24/2022] [Accepted: 09/24/2022] [Indexed: 12/12/2022]
|
8
|
Liang S, Sutham P, Wu K, Mallikarjunan K, Wang JP. Giant Magnetoresistance Biosensors for Food Safety Applications. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22155663. [PMID: 35957220 PMCID: PMC9371012 DOI: 10.3390/s22155663] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 07/25/2022] [Accepted: 07/26/2022] [Indexed: 05/25/2023]
Abstract
Nowadays, the increasing number of foodborne disease outbreaks around the globe has aroused the wide attention of the food industry and regulators. During food production, processing, storage, and transportation, microorganisms may grow and secrete toxins as well as other harmful substances. These kinds of food contamination from microbiological and chemical sources can seriously endanger human health. The traditional detection methods such as cell culture and colony counting cannot meet the requirements of rapid detection due to some intrinsic shortcomings, such as being time-consuming, laborious, and requiring expensive instrumentation or a central laboratory. In the past decade, efforts have been made to develop rapid, sensitive, and easy-to-use detection platforms for on-site food safety regulation. Herein, we review one type of promising biosensing platform that may revolutionize the current food surveillance approaches, the giant magnetoresistance (GMR) biosensors. Benefiting from the advances of nanotechnology, hundreds to thousands of GMR biosensors can be integrated into a fingernail-sized area, allowing the higher throughput screening of food samples at a lower cost. In addition, combined with on-chip microfluidic channels and filtration function, this type of GMR biosensing system can be fully automatic, and less operator training is required. Furthermore, the compact-sized GMR biosensor platforms could be further extended to related food contamination and the field screening of other pathogen targets.
Collapse
Affiliation(s)
- Shuang Liang
- Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, MN 55455, USA;
| | - Phanatchakorn Sutham
- Department of Food Science and Nutrition, University of Minnesota, St. Paul, MN 55108, USA;
| | - Kai Wu
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA
- Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, TX 79409, USA
| | - Kumar Mallikarjunan
- Department of Food Science and Nutrition, University of Minnesota, St. Paul, MN 55108, USA;
| | - Jian-Ping Wang
- Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, MN 55455, USA;
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, USA
| |
Collapse
|
9
|
Fluorescent Biosensors for the Detection of Viruses Using Graphene and Two-Dimensional Carbon Nanomaterials. BIOSENSORS 2022; 12:bios12070460. [PMID: 35884263 PMCID: PMC9312944 DOI: 10.3390/bios12070460] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/13/2022] [Accepted: 06/14/2022] [Indexed: 11/16/2022]
Abstract
Two-dimensional carbon nanomaterials have been commonly employed in the field of biosensors to improve their sensitivity/limits of detection and shorten the analysis time. These nanomaterials act as efficient transducers because of their unique characteristics, such as high surface area and optical, electrical, and magnetic properties, which in turn have been exploited to create simple, quick, and low-cost biosensing platforms. In this review, graphene and two-dimensional carbon material-based fluorescent biosensors are covered between 2010 and 2021, for the detection of different human viruses. This review specifically focuses on the new developments in graphene and two-dimensional carbon nanomaterials for fluorescent biosensing based on the Förster resonance energy transfer (FRET) mechanism. The high-efficiency quenching capability of graphene via the FRET mechanism enhances the fluorescent-based biosensors. The review provides a comprehensive reference for the different types of carbon nanomaterials employed for the detection of viruses such as Rotavirus, Ebola virus, Influenza virus H3N2, HIV, Hepatitis C virus (HCV), and Hepatitis B virus (HBV). This review covers the various multiplexing detection technologies as a new direction in the development of biosensing platforms for virus detection. At the end of the review, the different challenges in the use of fluorescent biosensors, as well as some insights into how to overcome them, are highlighted.
Collapse
|
10
|
On-chip-based electrochemical biosensor for the sensitive and label-free detection of Cryptosporidium. Sci Rep 2022; 12:6957. [PMID: 35484282 PMCID: PMC9051104 DOI: 10.1038/s41598-022-10765-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Accepted: 03/08/2022] [Indexed: 01/14/2023] Open
Abstract
Cryptosporidium, an intestinal protozoan pathogen, is one of the leading causes of death in children and diarrhea in healthy adults. Detection of Cryptosporidium has become a high priority to prevent potential outbreaks. In this paper, a simple, easy to fabricate, and cost-effective on-chip-based electrochemical biosensor has been developed for the sensitive and label-free detection of Cryptosporidium oocysts in water samples. The sensor was fabricated using standard lithography using a mask with a 3-electrode design and modified by self-assembling a hybrid of a thiolated protein/G and the specific anti-Cryptosporidium monoclonal antibodies (IgG3). The electrochemical impedance spectroscopy (EIS) was employed to quantitate C. parvum in the range of 0 to 300 oocysts, with a detection limit of approximately 20 oocysts/5 µL. The high sensitivity and specificity of the developed label-free electrochemical biosensor suggest that this novel platform is a significant step towards the development of fast, real-time, inexpensive and label-free sensing tool for early warning and immediate on-site detection of C. parvum oocysts in water samples, as compared to the traditional methods (such as PCR and microscopy). Furthermore, under optimized conditions, this label-free biosensor can be extended to detect other analytes and biomarkers for environmental and biomedical analyses.
Collapse
|
11
|
Giuffrida SG, Forysiak W, Cwynar P, Szweda R. Shaping Macromolecules for Sensing Applications—From Polymer Hydrogels to Foldamers. Polymers (Basel) 2022; 14:polym14030580. [PMID: 35160568 PMCID: PMC8840496 DOI: 10.3390/polym14030580] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 01/21/2022] [Accepted: 01/23/2022] [Indexed: 12/14/2022] Open
Abstract
Sensors are tools for detecting, recognizing, and recording signals from the surrounding environment. They provide measurable information on chemical or physical changes, and thus are widely used in diagnosis, environment monitoring, food quality checks, or process control. Polymers are versatile materials that find a broad range of applications in sensory devices for the biomedical sector and beyond. Sensory materials are expected to exhibit a measurable change of properties in the presence of an analyte or a stimulus, characterized by high sensitivity and selectivity of the signal. Signal parameters can be tuned by material features connected with the restriction of macromolecule shape by crosslinking or folding. Gels are crosslinked, three-dimensional networks that can form cavities of different sizes and forms, which can be adapted to trap particular analytes. A higher level of structural control can be achieved by foldamers, which are macromolecules that can attain well-defined conformation in solution. By increasing control over the three-dimensional structure, we can improve the selectivity of polymer materials, which is one of the crucial requirements for sensors. Here, we discuss various examples of polymer gels and foldamer-based sensor systems. We have classified and described applied polymer materials and used sensing techniques. Finally, we deliberated the necessity and potential of further exploration of the field towards the increased selectivity of sensory devices.
Collapse
Affiliation(s)
- Simone Giuseppe Giuffrida
- Łukasiewicz Research Network—PORT Polish Center for Technology Development, ul. Stabłowicka 147, 54-066 Wrocław, Poland; (S.G.G.); (W.F.); (P.C.)
| | - Weronika Forysiak
- Łukasiewicz Research Network—PORT Polish Center for Technology Development, ul. Stabłowicka 147, 54-066 Wrocław, Poland; (S.G.G.); (W.F.); (P.C.)
- Faculty of Chemistry, University of Wrocław, F. Joliot-Curie, 50-383 Wrocław, Poland
| | - Pawel Cwynar
- Łukasiewicz Research Network—PORT Polish Center for Technology Development, ul. Stabłowicka 147, 54-066 Wrocław, Poland; (S.G.G.); (W.F.); (P.C.)
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Roza Szweda
- Łukasiewicz Research Network—PORT Polish Center for Technology Development, ul. Stabłowicka 147, 54-066 Wrocław, Poland; (S.G.G.); (W.F.); (P.C.)
- Correspondence:
| |
Collapse
|
12
|
Microelectromechanical Systems (MEMS) for Biomedical Applications. MICROMACHINES 2022; 13:mi13020164. [PMID: 35208289 PMCID: PMC8875460 DOI: 10.3390/mi13020164] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/18/2022] [Accepted: 01/20/2022] [Indexed: 02/04/2023]
Abstract
The significant advancements within the electronics miniaturization field have shifted the scientific interest towards a new class of precision devices, namely microelectromechanical systems (MEMS). Specifically, MEMS refers to microscaled precision devices generally produced through micromachining techniques that combine mechanical and electrical components for fulfilling tasks normally carried out by macroscopic systems. Although their presence is found throughout all the aspects of daily life, recent years have witnessed countless research works involving the application of MEMS within the biomedical field, especially in drug synthesis and delivery, microsurgery, microtherapy, diagnostics and prevention, artificial organs, genome synthesis and sequencing, and cell manipulation and characterization. Their tremendous potential resides in the advantages offered by their reduced size, including ease of integration, lightweight, low power consumption, high resonance frequency, the possibility of integration with electrical or electronic circuits, reduced fabrication costs due to high mass production, and high accuracy, sensitivity, and throughput. In this context, this paper aims to provide an overview of MEMS technology by describing the main materials and fabrication techniques for manufacturing purposes and their most common biomedical applications, which have evolved in the past years.
Collapse
|
13
|
Kamali P, Zandi M, Ghasemzadeh-Moghaddam H, Fani M. Comparison between various biosensor methods for human T-lymphotropic virus-1 (HTLV-1) detection. Mol Biol Rep 2021; 49:1513-1517. [PMID: 34797491 DOI: 10.1007/s11033-021-06959-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Accepted: 11/11/2021] [Indexed: 11/25/2022]
Abstract
Due to the drawback of traditional and current diagnostic methods including serological and molecular assays, the development of the rapid and free-PCR techniques can be an alternative technique for the human T-cell lymphotropic virus (HTLV-1) DNA detection sequences. On the other hand, early detection of HTLV-1 prevents two dangerous diseases including Adult T-cell leukemia/lymphoma and HTLV-1 Associated Myelopathy/Tropical Spastic Paraparesis. The biosensor-based methods are sensitive techniques that can provide new opportunities to detect infectious diseases, particularly in the early stage. This study provides a comparative view among recently designed biosensors for the detection of HTLV-1.
Collapse
Affiliation(s)
- Peyman Kamali
- Department of Modern Sciences and Technologies, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Milad Zandi
- Department of Virology, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| | - Hamed Ghasemzadeh-Moghaddam
- Department of Pathobiology and Laboratory Sciences, School of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran
- Vector-Borne Diseases Research Center, North Khorasan University of Medical Sciences, Bojnurd, Iran
| | - Mona Fani
- Department of Pathobiology and Laboratory Sciences, School of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran.
- Vector-Borne Diseases Research Center, North Khorasan University of Medical Sciences, Bojnurd, Iran.
| |
Collapse
|
14
|
Chircov C, Bîrcă AC, Grumezescu AM, Vasile BS, Oprea O, Nicoară AI, Yang CH, Huang KS, Andronescu E. Synthesis of Magnetite Nanoparticles through a Lab-On-Chip Device. MATERIALS (BASEL, SWITZERLAND) 2021; 14:5906. [PMID: 34640303 PMCID: PMC8510126 DOI: 10.3390/ma14195906] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Revised: 10/01/2021] [Accepted: 10/03/2021] [Indexed: 01/21/2023]
Abstract
Magnetite nanoparticles (MNPs) represent one of the most intensively studied types of iron oxide nanoparticles in various fields, including biomedicine, pharmaceutics, bioengineering, and industry. Since their properties in terms of size, shape, and surface charge significantly affects their efficiency towards the envisaged application, it is fundamentally important to develop a new synthesis route that allows for the control and modulation of the nanoparticle features. In this context, the aim of the present study was to develop a new method for the synthesis of MNPs. Specifically, a microfluidic lab-on-chip (LoC) device was used to obtain MNPs with controlled properties. The study investigated the influence of iron precursor solution concentration and flowed onto the final properties of the nanomaterials. The synthesized MNPs were characterized in terms of size, morphology, structure, composition, and stability. Results proved the formation of magnetite as a single mineral phase. Moreover, the uniform spherical shape and narrow size distribution were demonstrated. Optimal characteristics regarding MNPs crystallinity, uniformity, and thermal stability were obtained at higher concentrations and lower flows. In this manner, the potential of the LoC device is a promising tool for the synthesis of nanomaterials by ensuring the necessary uniformity for all final applications.
Collapse
Affiliation(s)
- Cristina Chircov
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania; (C.C.); (A.C.B.); (B.S.V.); (A.I.N.); (E.A.)
| | - Alexandra Cătălina Bîrcă
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania; (C.C.); (A.C.B.); (B.S.V.); (A.I.N.); (E.A.)
| | - Alexandru Mihai Grumezescu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania; (C.C.); (A.C.B.); (B.S.V.); (A.I.N.); (E.A.)
- Research Institute of the University of Bucharest—ICUB, University of Bucharest, 050657 Bucharest, Romania
- Academy of Romanian Scientists, 54 Spl. Independentei, 050045 Bucharest, Romania
| | - Bogdan Stefan Vasile
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania; (C.C.); (A.C.B.); (B.S.V.); (A.I.N.); (E.A.)
| | - Ovidiu Oprea
- Department of Inorganic Chemistry, Physical Chemistry and Electrochemistry, University Politehnica of Bucharest, 1-7 Polizu St., 011061 Bucharest, Romania;
| | - Adrian Ionuț Nicoară
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania; (C.C.); (A.C.B.); (B.S.V.); (A.I.N.); (E.A.)
| | - Chih-Hui Yang
- Department of Biological Science and Technology, I-Shou University, Kaohsiung 824, Taiwan;
- Pharmacy Department of E-Da Hospital, Kaohsiung 824, Taiwan
- Taiwan Instrument Research Institute, National Applied Research Laboratories, Hsinchu 300, Taiwan
| | - Keng-Shiang Huang
- The School of Chinese Medicine for Post-Baccalaureate, I-Shou University, Kaohsiung 840301, Taiwan;
| | - Ecaterina Andronescu
- Department of Science and Engineering of Oxide Materials and Nanomaterials, University Politehnica of Bucharest, 011061 Bucharest, Romania; (C.C.); (A.C.B.); (B.S.V.); (A.I.N.); (E.A.)
- Academy of Romanian Scientists, 54 Spl. Independentei, 050045 Bucharest, Romania
| |
Collapse
|
15
|
Niculescu AG, Chircov C, Grumezescu AM. Magnetite nanoparticles: Synthesis methods - A comparative review. Methods 2021; 199:16-27. [PMID: 33915292 DOI: 10.1016/j.ymeth.2021.04.018] [Citation(s) in RCA: 58] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Revised: 04/18/2021] [Accepted: 04/22/2021] [Indexed: 12/28/2022] Open
Abstract
Iron oxide-based nanoparticles have gathered tremendous scientific interest towards their application in a variety of fields. Magnetite has been particularly investigated due to its readily availability, versatility, biocompatibility, biodegradability, and special magnetic properties. As the behavior of nano-scale magnetite is in direct relation to its shape, size, and surface chemistry, accurate control over the nanoparticle synthesis process is essential in obtaining quality products for the intended end uses. Several chemical, physical, and biological methods are found in the literature and implemented in the laboratory or industrial practice. However, non-conventional methods emerged in recent years to bring unprecedented synthesis performances in terms of better-controlled morphologies, sizes, and size distribution. Particularly, microfluidic methods represent a promising technology towards smaller reagent volume use, waste reduction, precise control of fluid mixing, and ease of automation, overcoming some of the major drawbacks of conventional bulk methods. This review aims to present the main properties, applications, and synthesis methods of magnetite, together with the newest advancements in this field.
Collapse
Affiliation(s)
| | - Cristina Chircov
- Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 011061 Bucharest, Romania.
| | - Alexandru Mihai Grumezescu
- Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 011061 Bucharest, Romania; Research Institute of the University of Bucharest-ICUB, University of Bucharest, 050657 Bucharest, Romania.
| |
Collapse
|
16
|
Niculescu AG, Chircov C, Bîrcă AC, Grumezescu AM. Nanomaterials Synthesis through Microfluidic Methods: An Updated Overview. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:864. [PMID: 33800636 PMCID: PMC8066900 DOI: 10.3390/nano11040864] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 03/14/2021] [Accepted: 03/24/2021] [Indexed: 01/10/2023]
Abstract
Microfluidic devices emerged due to an interdisciplinary "collision" between chemistry, physics, biology, fluid dynamics, microelectronics, and material science. Such devices can act as reaction vessels for many chemical and biological processes, reducing the occupied space, equipment costs, and reaction times while enhancing the quality of the synthesized products. Due to this series of advantages compared to classical synthesis methods, microfluidic technology managed to gather considerable scientific interest towards nanomaterials production. Thus, a new era of possibilities regarding the design and development of numerous applications within the pharmaceutical and medical fields has emerged. In this context, the present review provides a thorough comparison between conventional methods and microfluidic approaches for nanomaterials synthesis, presenting the most recent research advancements within the field.
Collapse
Affiliation(s)
- Adelina-Gabriela Niculescu
- Faculty of Engineering in Foreign Languages, University Politehnica of Bucharest, 060042 Bucharest, Romania;
| | - Cristina Chircov
- Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 060042 Bucharest, Romania; (C.C.); (A.C.B.)
| | - Alexandra Cătălina Bîrcă
- Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 060042 Bucharest, Romania; (C.C.); (A.C.B.)
| | - Alexandru Mihai Grumezescu
- Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 060042 Bucharest, Romania; (C.C.); (A.C.B.)
- Research Institute of the University of Bucharest—ICUB, University of Bucharest, 050657 Bucharest, Romania
| |
Collapse
|